Sample records for incident x-ray spectra

  1. Normal incidence X-ray telescope power spectra of X-ray emission from solar active regions. I - Observations. II - Theory

    Science.gov (United States)

    Gomez, Daniel O.; Martens, Petrus C. H.; Golub, Leon

    1993-01-01

    Fourier analysis is applied to very high resolution image of coronal active regions obtained by the Normal Incidence X-Ray Telescope is used to find a broad isotropic power-law spectrum of the spatial distribution of soft X-ray intensities. Magnetic structures of all sizes are present down to the resolution limit of the instrument. Power spectra for the X-ray intensities of a sample of topologically different active regions are found which fall off with increasing wavenumber as 1/k-cubed. A model is presented that relates the basic features of coronal magnetic fluctuations to the subphotospheric hydrodynamic turbulence that generates them. The model is used to find a theoretical power spectrum for the X-ray intensity which falls off with increasing wavenumber as 1/k-cubed. The implications of a turbulent regime in active regions are discussed.

  2. Optimum x-ray spectra for mammography.

    Science.gov (United States)

    Beaman, S A; Lillicrap, S C

    1982-10-01

    A number of authors have calculated x-ray energies for mammography using, as a criterion, the maximum signal-to-noise ratio (SNR) obtainable per unit dose to the breast or conversely the minimum exposure for constant SNR. The predicted optimum energy increases with increasing breast thickness. Tungsten anode x-ray spectra have been measured with and without various added filter materials to determine how close the resultant spectra can be brought to the predicted optimum energies without reducing the x-ray output to unacceptable levels. The proportion of the total number of x-rays in a measured spectrum lying within a narrow energy band centred on the predicted optimum has been used as an optimum energy index. The effect of various filter materials on the measured x-ray spectra has been investigated both experimentally and theoretically. The resulting spectra have been compared with molybdenum anode, molybdenum filtered x-ray spectra normally used for mammography. It is shown that filters with K-absorption edges close to the predicted optimum energies are the most effective at producing the desired spectral shape. The choices of filter thickness and Vp are also explored in relationship to their effect on the resultant x-ray spectral shape and intensity.

  3. Indirect measurements of X-ray spectra

    International Nuclear Information System (INIS)

    Mainardi, R.T.

    2006-01-01

    To the effects of measuring the spectral distribution of the radiation emitted by the x-ray tubes and electron accelerators, numerous procedures that are grouped in two big categories exist at the present time: direct and indirect methods. The first ones use high resolution detectors that should be positioned, together with the appropriate collimator, in the direction of the x ray beam. The user should be an expert in the use and correction of the obtained data by the different effects that affect the detector operation such as efficiency and resolution in terms of the energy of the detected radiation. The indirect procedures, although its are more simple to use, its also require a considerable space along the beam to position the ionization chamber and the necessary absorbents to construct by this way the denominated attenuation curve. We will analyze the operation principle of the indirect methods and a new proposal in which such important novelties are introduced as the beam dispersion to avoid to measure along the main beam and that of determination of the attenuation curve in simultaneous form. By this way, with a single shot of the tube, the attenuation curve is measured, being necessary at most a shot of additional calibration to know the relative response of the detectors used in the experimental array. The physical processes involved in the obtaining of an attenuation curve are very well well-known and this it finishes it can be theoretically calculated if the analytic form of the spectrum is supposed well-known. Finally, we will see a spectra reconstruction example with the Kramers parametric form and comparisons with numeric simulations carried out with broadly validated programs as well as the possibility of the use of solid state dosemeters in the obtention of the attenuation curve. (Author)

  4. The restoration of astronomical X-ray spectra

    International Nuclear Information System (INIS)

    Blissett, R.J.; Cruise, A.M.

    1979-01-01

    The present limitations in the measurement of astronomical X-ray spectra are discussed with particular regard to the poor spectral resolution of gas proportional counters. The problem of inferring an incident photon spectrum from the data is considered. Current procedures and their drawbacks are outlined, and a direct method of solution is derived by presenting the data as a Fredholm integral equation of the first kind. This approach utilizes singular function decomposition of the resolution operator with appropriate filtering to stabilize the solution in the presence of noise. After illustrating the operation of this technique on computer simulated data, analysis of Ariel V data is presented. The general applicability of this method of analysis in X-ray astronomy is considered. (author)

  5. The X-ray spectra of active galactic nuclei

    International Nuclear Information System (INIS)

    Culhane, J.L.

    1984-01-01

    Recent observations of the X-ray spectra of active galactic nuclei are reviewed. After an outline of the properties of these sources deduced from observations at other wavelengths, the relevance of X-ray spectra to our understanding of the X-ray emission mechanisms and of the ultimate source of energy is discussed. The emission and absorption features that are observed arise from the interaction of the X-rays from the active nuclei with the surrounding gas. Observations of these features are reviewed and the information they provide on the nature of the surrounding gas is discussed. (Auth.)

  6. Chemical effects in x-ray emission spectra

    International Nuclear Information System (INIS)

    Fernandes, N.G.

    1982-01-01

    The chemical bond influence in X-ray emission spectra of hafnium, iodine, iron, sulphur, aluminium and magnesium is detected. The position of one X-ray emission line is determined by three methods: parabolic profile; Gaussian distribution and extra-heavy maximum. (author)

  7. X ray spectra measurement using a CdTe detector

    International Nuclear Information System (INIS)

    Kurkova, D.; Judas, L.

    2014-01-01

    X ray spectra were measured using a CdTe XR-100T detector (Amptek). Spectra of N series were measured (according to ISO 4037-1:1996): from N60 to N150 for anode voltage of the tube 60-150 kV, realised by x ray tubeIsovolt Titan in dosimetric laboratory SURO, v.v.i.. Two sets of spectra were measured - first without using the tungsten collimator kit of the spectrometer, in a distance of 7 m from x ray tube and low tube current and second using a tungsten collimator kit measured in a distance 1 m from x ray tube focus and low tube current. Elimination of random coincidences was achieved by reduction of counting rates on the detection system. Further artefacts in measured spectra were compensated using an analytic response matrix. Response matrix was computed and subsequently applied in a program made in MATLAB. We demonstrate a function of response matrix on both model physical spectra and measured spectra. In consequence of mainly continuous character of measured spectra more parameters are needed for its description compared to the line spectra. Therefore we came up with additional parameters for characterization and mutual comparison of x ray spectra. (authors)

  8. X-ray spectra of PG quasars. I. The continuum from X-rays to infrared

    International Nuclear Information System (INIS)

    Elvis, M.; Green, R.F.; Bechtold, J.; Schmidt, M.; Neugebauer, G.; Kitt Peak National Observatory, Tucson, AZ; Steward Observatory, Tucson, AZ; Palomar Observatory, Pasadena, CA)

    1986-01-01

    Einstein IPC X-ray spectra for a sample of eight optically selected quasars from the Palomar Bright Quasar survey are presented. The quasars have a mean power law energy slope which in five individual cases is inconsistent with the value found in hard X-ray selection criterion rather than luminosity, redshift, or U-B color. New IUE and optical continuum spectra and infrared photometry are presented for these quasars. The data are combined into log vf(v) and log v distributions which support the decomposition of the overall quasar spectrum into a power law plus a superposed optical-UV big bump which may be due to an accretion disk. At least six of the quasars have vf(v)s which are roughly constant between their infrared and X-ray power laws, suggesting a strong link between the two regions. 104 references

  9. X-ray Spectra of Distant Clusters

    Science.gov (United States)

    Ellingson, E.

    1998-01-01

    The masses of galaxy clusters are dominated by dark matter, and a robust determination of their temperatures and masses has the potential of indicating how much dark matter exists on large scales in the universe, and the cosmological parameter Omega. X-ray observations of galaxy clusters provide a direct measure of both the gas mass in the intra-cluster medium, and also the total gravitating mass of the cluster. We used new and archival ASCA and ROSAT observations to measure these quantities for a sample of intermediate redshift clusters which have also been subject to intensive dynamical studies, in order to compare the mass estimates from different methods. We used data from 12 of the CNOC cluster sample at 0.18 less than z less than 0.55 for this study. A direct comparison of dynamical mass estimates from Carlberg, Yee & Ellingson (1997) yielded surprisingly good results. The X-ray/dynamical mass ratios have a mean of 0.96+/- 0.10, indicating that for this sample, both methods are probably yielding very robust mass estimates. Comparison with mass estimates from gravitational lensing studies from the literature showed a small systematic with weak lensing estimates, and large discrepancies with strong lensing estimates. This latter is not surprising, given that these measurements are made close to the central core, where optical and Xray estimates are less certain, and where substructure and the effects of individual galaxies will be more pronounced. These results are presented in Lewis, Ellingson, Morris \\& Carlberg, 1998, submitted to the Astrophysical Journal.

  10. High-resolution x-ray photoemission spectra of silver

    DEFF Research Database (Denmark)

    Barrie, A.; Christensen, N. E.

    1976-01-01

    An electron spectrometer fitted with an x-ray monochromator for Al Kα1,2 radiation (1486.6 eV) has been used to record high-resolution x-ray photoelectron spectra for the 4d valence band as well as the 3d spin doublet in silver. The core-level spectrum has a line shape that can be described...

  11. Adjustable Grazing-Incidence X-Ray Optics

    Science.gov (United States)

    O'Dell, Stephen L.; Reid, Paul B.

    2015-01-01

    With its unique subarcsecond imaging performance, NASA's Chandra X-ray Observatory illustrates the importance of fine angular resolution for x-ray astronomy. Indeed, the future of x-ray astronomy relies upon x-ray telescopes with comparable angular resolution but larger aperture areas. Combined with the special requirements of nested grazing-incidence optics, mass, and envelope constraints of space-borne telescopes render such advances technologically and programmatically challenging. The goal of this technology research is to enable the cost-effective fabrication of large-area, lightweight grazing-incidence x-ray optics with subarcsecond resolution. Toward this end, the project is developing active x-ray optics using slumped-glass mirrors with thin-film piezoelectric arrays for correction of intrinsic or mount-induced distortions.

  12. Analysis of X-Ray (L) spectra of heavy elements

    International Nuclear Information System (INIS)

    Souza Coelho, L.F. de.

    1976-08-01

    The general problem of obtaining and analysing spectra is presented, with emphasis in the comparison of methods for the analysis of gamma rays and X rays. The method proposed to obtain a standard and later the intensities of lines of an X-ray (L) spectrum is discussed. The good eesults obtained by the program RAIOXL, when simulated spectra are used, and by the program RAIXL1, when doublets are decomposed, are shown. In annex A, the listings of the programs used are presented, and in annex B a review is made of the analytical formulae used for adjustment of the pulses. (I.C.R.) [pt

  13. Grazing Incidence X-ray Scattering and Diffraction

    Indian Academy of Sciences (India)

    IAS Admin

    tion. In thia article, various aspects of surface X- ray diffraction and scattering are discussed with illustrations of some typical applications of these techniques. 1. ..... ray reflectivity. Here, X-rays are incident on the sample at very small grazing angles to the surface and below the critical angle, αc. As explained earlier, this ...

  14. The Marshall Grazing Incidence X-ray Spectrometer

    Science.gov (United States)

    Kobayashi, Ken; Winebarger, Amy R.; Savage, Sabrina; Champey, Patrick; Cheimets, Peter N.; Hertz, Edward; Bruccoleri, Alexander R.; Golub, Leon; Ramsey, Brian; Ranganathan, Jaganathan; Marquez, Vanessa; Allured, Ryan; Parker, Theodore; Heilmann, Ralf K.; Schattenburg, Mark L.

    2017-08-01

    The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument designed to obtain spatially resolved soft X-ray spectra of the solar atmosphere in the 6-24 Å (0.5-2.0 keV) range. The instrument consists of a single shell Wolter Type-I telescope, a slit, and a spectrometer comprising a matched pair of grazing incidence parabolic mirrors and a planar varied-line space diffraction grating. The instrument is designed to achieve a 50 mÅ spectral resolution and 5 arcsecond spatial resolution along a +/-4-arcminute long slit, and launch is planned for 2019. We report on the status and our approaches for fabrication and alignment for this novel optical system. The telescope and spectrometer mirrors are replicated nickel shells, and are currently being fabricated at the NASA Marshall Space Flight Center. The diffraction grating is currently under development by the Massachusetts Institute of Technology (MIT); because of the strong line spacing variation across the grating, it will be fabricated through e-beam lithography.

  15. Design and development of grazing incidence x-ray mirrors

    Science.gov (United States)

    Zuo, Fuchang; Mei, Zhiwu; Ma, Tao; Deng, Loulou; Shi, Yongqiang; Li, Liansheng

    2016-01-01

    X-ray pulsar navigation has attracted extensive attentions from academy and engineering domains. The navigation accuracy is can be enhanced through design of X-ray mirrors to focus X-rays to a small detector. The Wolter-I optics, originally proposed based on a paraboloid mirror and a hyperboloid mirror for X-ray imaging, has long been widely developed and employed in X-ray observatory. Some differences, however, remain in the requirements on optics between astronomical X-ray observation and pulsar navigation. The simplified Wolter-I optics, providing single reflection by a paraboloid mirror, is more suitable for pulsar navigation. In this paper, therefore, the grazing incidence X-ray mirror was designed further based on our previous work, with focus on the reflectivity, effective area, angular resolution and baffles. To evaluate the performance of the manufactured mirror, the surface roughness and reflectivity were tested. The test results show that the grazing incidence mirror meets the design specifications. On the basis of this, the reflectivity of the mirror in the working bandwidth was extrapolated to evaluate the focusing ability of the mirror when it works together with the detector. The purpose of our current work to design and develop a prototype mirror was realized. It can lay a foundation and provide guidance for the development of multilayer nested X-ray mirror with larger effective area.

  16. Grazing Incidence X-Ray Fluorescence of periodic structures – a comparison between X-ray Standing Waves and Geometrical Optics calculations.

    OpenAIRE

    Reinhardt Falk; Nowak Stanislaw H.; Beckhoff Burkhard; Dousse Jean-Claude; Schoengen Max

    2014-01-01

    Grazing incidence X-ray fluorescence spectra of nano-scaled periodic line structures were recorded at the four crystal monochromator beamline in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II. For different tilt angles between the lines and the plane of incidence of the monochromatic synchrotron radiation, spectral features are observed which can be understood and explained with calculations of the emerging X-ray standing wave (XSW) ...

  17. Tetrahedral hydrocarbon nanoparticles in space: X-ray spectra

    Science.gov (United States)

    Bilalbegović, G.; Maksimović, A.; Valencic, L. A.

    2018-03-01

    It has been proposed, or confirmed, that diamond nanoparticles exist in various environments in space: close to active galactic nuclei, in the vicinity of supernovae and pulsars, in the interior of several planets in the Solar system, in carbon planets and other exoplanets, carbon-rich stars, meteorites, in X-ray active Herbig Ae/Be stars, and in the interstellar medium. Using density functional theory methods we calculate the carbon K-edge X-ray absorption spectrum of two large tetrahedral nanodiamonds: C26H32 and C51H52. We also study and test our methods on the astrophysical molecule CH4, the smallest C-H tetrahedral structure. A possible detection of nanodiamonds from X-ray spectra by future telescopes, such as the project Arcus, is proposed. Simulated spectra of the diffuse interstellar medium using Cyg X-2 as a source show that nanodiamonds studied in this work can be detected by Arcus, a high resolution X-ray spectrometer mission selected by NASA for a Phase A concept study.

  18. X-ray absorption spectra and emission spectra of plasmas

    International Nuclear Information System (INIS)

    Peng Yonglun; Yang Li; Wang Minsheng; Li Jiaming

    2002-01-01

    The author reports a theoretical method to calculate the resolved absorption spectra and emission spectra (optically thin) of hot dense plasmas. Due to its fully relativistic treatment incorporated with the quantum defect theory, it calculates the absorption spectra and emission spectra for single element or multi-element plasmas with little computational efforts. The calculated absorption spectra of LTE gold plasmas agree well with the experimental ones. It also calculates the optical thin emission spectra of LTE gold plasmas, which is helpful to diagnose the plasmas of relevant ICF plasmas. It can also provide the relevant parameters such as population density of various ionic stages, precise radiative properties for ICF studies

  19. Indirect measure of X-rays spectra using TLDs

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.

    2011-10-01

    A methodology of indirect measure of X-rays spectra, emitted by conventional tubes, was developed recently and its feasibility verified in the first place by Monte Carlo simulations. For that case is intended to measure, by means of plastic scintillators, attenuation curves of dispersed beams previously. In this work were carried out measurements of attenuation curves with thermoluminescent dosimeters (TLD) to verify the kindness of the indirect measure method. The attenuation curve was also measured using an ionization chamber brand Capintec (model 192) with the purpose of making a comparison. The results of the attenuation curve measured with both dosimeters present a good resolution inside the statistical fluctuations and the spectral reconstruction using diverse parametric functions is carried out in a quick and simple way with excellent resolutions in the functional form. For this reconstruction method are of fundamental importance the following properties of the used dosimeter: in the first place the repetition of the measures, property that could check; in second place the precision of the measured data and lastly the dosimeter response, this is, the increase of the thermoluminescent signal before an increase of the photons flow of X-rays. This parameter is the gradient of the curve thermoluminescent signal versus the dose imparted to the dosimeter. The measures were realized with a generator of X-rays brand Kevex provided of a conventional tube with tungsten anti cathode that polarizes with high tension to a maximum value of 50 kV and current of 0.5 ma. (Author)

  20. The high energy X-ray spectra of supernova remnants

    Science.gov (United States)

    Pravdo, S. H.; Nugent, J. J.

    The results of fitting an ionization-nonequilibrium (INE) model to the high-energy (above 5-keV) X-ray spectra of the young supernova remnants Cas A and Tycho are presented. As an additional constraint, the models must simultaneously fit lower-energy, higher-resolution data. For Cas A, a single INE component cannot adequately reproduce the features for the entire X-ray spectrum because the ionization structure of iron ions responsible for the K emission is inconsistent with that of the ions responsible for the lower-energy lines, and the flux of the highest-energy X-rays is underestimated. The iron K line and the high-energy continuum could arise from the same INE component, but the identification of this component with either the blast wave or the ejecta in the standard model is difficult. In Tycho, the high-energy data rule out a class of models for the lower-energy data which have too large a continuum contribution.

  1. Quantum chemistry interpretation of x-ray spectra

    International Nuclear Information System (INIS)

    Bocharov, D.; Kuzmin, A.

    2005-01-01

    Full text: In this study, we present the results of ab initio computer simulations on X-ray absorption spectra of some perovskite-type tungsten oxides. For our calculations, we combine a periodic bulk model with Hartree-Fock method including a posteriori electron correlation corrections, as implemented in CRYSTAL98 computer code [1]. First, we describe the results of calculations performed on some bulk properties of the tungsten oxides (lattice constant and bulk modulus), in order to achieve the necessary level of agreement with available experimental and theoretical data. Our calculations on the densities of oneelectron energy states (DOS) for models of tungsten oxides are verified by experimental X-ray absorption spectra, which allow us to make correct qualitative interpretation of the latter. The main difficulties appearing during our first principles simulations will be discussed. [1] V.R. Saunders, R. Dovesi, C. Roetti, M. Causi, N.M. Harrison, R. Orlando, and C.M. Zicovich-Wilson, CRYSTAL-98 User Manual, University of Turin, 1999

  2. Optimization and energy spectra of x-ray to be used for imaging

    International Nuclear Information System (INIS)

    Nakamori, Nobuyuki; Kanamori, Hitoshi

    1979-01-01

    The relations of the spectra of X-ray used for diagnosis to the absorbed dose of patients and X-ray information are now being investigated by a number of investigators. Here the problems and the trends of the investigations at present are described. Advent of semiconductor detectors has improved the accuracy of measuring X-ray spectra very rapidly. However, since the semiconductor detectors themselves utilize X-ray photon absorption, calibration curves must be prepared for obtaining the true X-ray spectra. Though there are methods of theoretically determining X-ray spectra, no definite theoretical formula is found. Thus, the derivation of an empirical equation based on measured data would be the most fundamental problem. Interactions in an object and the change of X-ray spectra are described on the case of monochromatic and continuous X-ray irradiation. As mentioned above, beam hardening occurs when X-ray enters a matter deep, because the interactions between X-ray and the matter depend upon the photon energy. There are a few methods for correcting the variation of CT (computed tomography) number due to beam hardening. However, prior to this, there are two methods of representing continuous X-ray with single energy, and the unification of the methods or a new way of defining X-ray quality is needed. It has been and is always desirable that monochromatic X-ray source becomes to be useable, and various methods are proposed. (Wakatsuki, Y.)

  3. X ray spectra produced by NaF implosions

    Science.gov (United States)

    Mehlman, G.; Newman, D. A.; Burkhalter, P. G.

    1989-11-01

    Spatially-resolved x ray spectra were collected of imploding sodium plasmas using the Naval Research Laboratory Gamble 11 pulsed-power generator. A capillary-discharge was used as the source to inject sodium-fluoride plasmas for the fast Z-pinch implosion experiments. The plasma images recorded by curved-crystal spectrographs correspond to intense emission from a 3.5 cm long plasma column in the 4 cm interelectrode gap. Absolute emissivity values were obtained for the radiation emitted in the Na X and Na XI discrete transitions as well as for the total K-shell emission over the spectral range 800 to 1600 eV. Plasma parameters were determined from the measured spectral intensities compared to the ones predicted by plasma radiation theory. In regions near the nozzle, electron densities of several times 10 to the 21st power 3/cm and electron temperatures of 200 to 300 eV are generated.

  4. An X-ray grazing incidence phase multilayer grating

    CERN Document Server

    Chernov, V A; Mytnichenko, S V

    2001-01-01

    An X-ray grazing incidence phase multilayer grating, representing a thin grating placed on a multilayer mirror, is proposed. A high efficiency of grating diffraction can be obtained by the possibility of changing the phase shift of the wave diffracted from the multilayer under the Bragg and total external reflection conditions. A grazing incidence phase multilayer grating consisting of Pt grating stripes on a Ni/C multilayer and optimized for the hard X-ray range was fabricated. Its diffraction properties were studied at photon energies of 7 and 8 keV. The obtained maximum value of the diffraction efficiency of the +1 grating order was 9% at 7 keV and 6.5% at 8 keV. The data obtained are in a rather good accordance with the theory.

  5. X-ray-binary spectra in the lamp post model

    Science.gov (United States)

    Vincent, F. H.; Różańska, A.; Zdziarski, A. A.; Madej, J.

    2016-05-01

    Context. The high-energy radiation from black-hole binaries may be due to the reprocessing of a lamp located on the black hole rotation axis and emitting X-rays. The observed spectrum is made of three major components: the direct spectrum traveling from the lamp directly to the observer; the thermal bump at the equilibrium temperature of the accretion disk heated by the lamp; and the reflected spectrum essentially made of the Compton hump and the iron-line complex. Aims: We aim to accurately compute the complete reprocessed spectrum (thermal bump + reflected) of black-hole binaries over the entire X-ray band. We also determine the strength of the direct component. Our choice of parameters is adapted to a source showing an important thermal component. We are particularly interested in investigating the possibility to use the iron-line complex as a probe to constrain the black hole spin. Methods: We computed in full general relativity the illumination of a thin accretion disk by a fixed X-ray lamp along the rotation axis. We used the ATM21 radiative transfer code to compute the local, energy-dependent spectrum emitted along the disk as a function of radius, emission angle and black hole spin. We then ray traced this local spectrum to determine the final reprocessed spectrum as received by a distant observer. We consider two extreme values of the black hole spin (a = 0 and a = 0.98) and discuss the dependence of the local and ray-traced spectra on the emission angle and black hole spin. Results: We show the importance of the angle dependence of the total disk specific intensity spectrum emitted by the illuminated atmosphere when the thermal disk emission is fully taken into account. The disk flux, together with the X-ray flux from the lamp, determines the temperature and ionization structure of the atmosphere. High black hole spin implies high temperature in the inner disk regions, therefore, the emitted thermal disk spectrum fully covers the iron-line complex. As a

  6. Modern approaches to investigation of thin films and monolayers: X-ray reflectivity, grazing-incidence X-ray scattering and X-ray standing waves

    Science.gov (United States)

    Shcherbina, M. A.; Chvalun, S. N.; Ponomarenko, S. A.; Kovalchuk, M. V.

    2014-12-01

    The review concerns modern experimental methods of structure determination of thin films of different nature. The methods are based on total reflection of X-rays from the surface and include X-ray reflectivity, grazing-incidence X-ray scattering and X-ray standing waves. Their potential is exemplified by the investigations of various organic macromolecular systems that exhibit the properties of semiconductors and are thought to be promising as thin-film transistors, light-emitting diodes and photovoltaic cells. It is shown that combination of the title methods enable high-precision investigations of the structure of thin-film materials and structure formation in them, i.e., it is possible to obtain information necessary for improvement of the operating efficiency of elements of organic electronic devices. The bibliography includes 92 references.

  7. The Soft X-Ray Spectra of Sulfur Compounds.

    Science.gov (United States)

    Zhou, Ling

    1995-01-01

    The sulfur compounds including CdS, ZnS, rm MoS_2, WS_2, NiS, FeS, GaS, SnS, MgS and Alloy rm ZnS_{x }Se_{1-x} were investigated by using photon/e-beam excited soft x-ray spectroscopy through SXA, SXE, SXF and inelastic Resonant Raman scattering and resonant elastic scattering processes. For valence bands, the PDOS of S L_{2,3}, Zn M_{2,3}, Se M _{4,5}, bands locations, band gaps Eg, core level spin splitting, the lifetime broadening of valence band t_{1/2}, branching ratio of rm L_2/L_3 and shallow d level and exciton state were measured in some of these materials respectively. The excitation mechanism or threshold effects were studied for CdS, ZnS, MoS_2, WS_2, FeS, NiS, and alloy. In photon excited S L_ {2,3}^ectra, local core levels with spin splitting were found to charge threshold effects. The threshold effects are also found to be influenced by resonant elastic and inelastic scattering process. A simple model and the second order perturbation theory are used to explain the observed inelastic Raman scattering of Zn M _{2,3} spectra near d threshold. The d participation in the chemical bonding and interactions was studied. Atomiclike d bands were found in FeS and NiS from strong d-d and d-p couplings. Two groups of d bands were observed in Transitional Metal Sulfides (TMS) and the no-bonding group with a few d bands was found to across whole valence bands in TMS. The direct connection between valence bands and conduction bands is built and some conduction bands were studied. A study of alloy was included briefly. These experiments provide a rich information about TMS, and prove that Soft X-ray Spectroscopy is a powerful, precise and reliable tool in the study of fine electronic band structure in solids.

  8. Multiple ionization effects in low-resolution X-ray spectra induced by energetic heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Banas, D. E-mail: dariusz.banas@pu.kielce.pl; Pajek, M.; Semaniak, J.; Braziewicz, J.; Kubala-Kukus, A.; Majewska, U.; Czyzewski, T.; Jaskola, M.; Kretschmer, W.; Mukoyama, T.; Trautmann, D

    2002-10-01

    The method of analysis of the multiple ionization effects in low-resolution X-ray spectra induced by heavy ions is described here. It is shown that, by fitting the X-ray spectra measured by a semiconductor detector with the proposed model, which accounts for the multiple ionization effects, the ionization probabilities can be determined as free fitting parameters. This approach is based on the assumption that the intensity distribution of emitted X-ray satellites is approximately described by the binomial distribution parameterized by the ionization probability at the moment of X-ray emission. In particular, we demonstrate that the excited X-ray satellites, when measured by a low-resolution semiconductor detector, appear as the Gaussian profile, which is shifted and broadened with respect to the diagram line. Moreover, we find that both X-ray line shift and width are expressed in terms of the multiple ionization probabilities, as well as the X-ray energy shifts per vacancy. These observations allowed to develop a novel method of X-ray spectra fitting. Detailed discussion of the approximations used in the present approach is given. The method developed, using the calculated Dirac-Fock X-ray energy shifts per vacancy, was applied to determine the multiple ionization probabilities in M- and N-shell by fitting the measured X-ray spectra for L{gamma}(L{yields}N,O) transitions induced by heavy ions in selected high-Z atoms.

  9. X-ray measurements on wood - spectra measurements

    DEFF Research Database (Denmark)

    Jensen, Signe Kamp; Thygesen, Lisbeth Garbrecht; Gerward, Leif

    The report concerns simultaneous non-destructive measurements of water content and density of wood. Theoretically, this should be possible using a x-ray equipment newly build at BKM, and this work is an attempt to use the equipment for assessing water content and density of wood samples under...... laboratory conditions. A number of wood samples with different densities are placed at different relative humidities from 0.5 to 97 %RH. When equilibrium is obtained the samples are measured with the x-ray equipment such that 10 points are measured in the sample followed by measurements outside the sample...... (free-scanning). In this way 100 points are measured for each wood sample. This produces information about moisture content and density of the samples as water and wood attenuations of the x-rays are different for the different energy levels contained in the x-rays. The "real" density and moisture...

  10. X-ray microscopy using grazing-incidence reflection optics

    International Nuclear Information System (INIS)

    Price, R.H.

    1981-01-01

    The Kirkpatrick-Baez microscopes are described along with their role as the workhorse of the x-ray imaging devices. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics

  11. Copper L X-ray spectra measured by a high resolution ion-induced X-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Ryohei; Hamaguchi, Dai; Kageyama, Hiroyoshi [Kyoto Inst. of Tech. (Japan)] [and others

    1997-03-01

    High resolution L X-ray emission spectra of Cu have been measured by 0.75 MeV/u H, He, and F, 0.73 MeV/u Ar, 0.64 MeV/u Si, and 0.073 MeV/u Si ion impacts with a crystal spectrometer. The X-ray transition energies in the Cu target for L{iota}, L{eta}, L{alpha}{sub 1,2}, L{beta}{sub 1}, and L{beta}{sub 3,4} diagram lines induced by light ion impacts are determined, which are in good agreement with those given in the reference. The difference in L X-ray emission spectra produced by H, He, F, Si, and Ar ions are considered and the L{alpha}{sub 1,2} and L{beta}{sub 1} emission spectra are compared with the calculated ones based on the multiconfiguration Dirac-Fock method. (author)

  12. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: a Monte Carlo study.

    Science.gov (United States)

    Manohar, Nivedh; Jones, Bernard L; Cho, Sang Hyun

    2014-10-01

    To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the investigated range of 81-100 ke

  13. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study

    Science.gov (United States)

    Manohar, Nivedh; Jones, Bernard L.; Cho, Sang Hyun

    2014-01-01

    Purpose: To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). Methods: A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Results: Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the

  14. Direct measurement of clinical mammographic x-ray spectra using a CdTe spectrometer.

    Science.gov (United States)

    Santos, Josilene C; Tomal, Alessandra; Furquim, Tânia A; Fausto, Agnes M F; Nogueira, Maria S; Costa, Paulo R

    2017-07-01

    To introduce and evaluate a method developed for the direct measurement of mammographic x-ray spectra using a CdTe spectrometer. The assembly of a positioning system and the design of a simple and customized alignment device for this application is described. A positioning system was developed to easily and accurately locate the CdTe detector in the x-ray beam. Additionally, an alignment device to line up the detector with the central axis of the radiation beam was designed. Direct x-ray spectra measurements were performed in two different clinical mammography units and the measured x-ray spectra were compared with computer-generated spectra. In addition, the spectrometer misalignment effect was evaluated by comparing the measured spectra when this device is aligned relatively to when it is misaligned. The positioning and alignment of the spectrometer have allowed the measurements of direct mammographic x-ray spectra in agreement with computer-generated spectra. The most accurate x-ray spectral shape, related with the minimal HVL value, and high photon fluence for measured spectra was found with the spectrometer aligned according to the proposed method. The HVL values derived from both simulated and measured x-ray spectra differ at most 1.3 and 4.5% for two mammography devices evaluated in this study. The experimental method developed in this work allows simple positioning and alignment of a spectrometer for x-ray spectra measurements given the geometrical constraints and maintenance of the original configurations of mammography machines. © 2017 American Association of Physicists in Medicine.

  15. X-ray photoelectron spectra of γ-irradiated perfluorobenzene

    International Nuclear Information System (INIS)

    Sunder, S.; Sagert, N.H.; Wood, D.D.; Miller, N.H.

    1990-01-01

    The effect of γ-radiolysis on perfluorobenzene (PFB) was investigated using low-temperature X-ray photoelectron spectroscopy (XPS). PFB was irradiated in fluorine-passivated nickel cells using Co 60 γ-rays in an Atomic Energy of Canada Limited Gammacell at a dose rate of about 2.6 Gy·s -1 and for a total dose of about 50 kGy. The γ-radiolysis of PFB not only results in cross-linkage but also in the formation of saturated carbon centers in the PFB, as indicated by the presence of CF 2 and CF 3 groups. The relative abundance of CF, CF 2 and CF 3 groups, in the irradiated PFB, was estimated to be about 86, 9 and 5%, respectively

  16. Normal incidence X-ray mirror for chemical microanalysis

    Science.gov (United States)

    Carr, Martin J.; Romig, Jr., Alton D.

    1990-01-01

    A non-planar, focusing mirror, to be utilized in both electron column instruments and micro-x-ray fluorescence instruments for performing chemical microanalysis on a sample, comprises a concave, generally spherical base substrate and a predetermined number of alternating layers of high atomic number material and low atomic number material contiguously formed on the base substrate. The thickness of each layer is an integral multiple of the wavelength being reflected and may vary non-uniformly according to a predetermined design. The chemical analytical instruments in which the mirror is used also include a predetermined energy source for directing energy onto the sample and a detector for receiving and detecting the x-rays emitted from the sample; the non-planar mirror is located between the sample and detector and collects the x-rays emitted from the sample at a large solid angle and focuses the collected x-rays to the sample. For electron column instruments, the wavelengths of interest lie above 1.5 nm, while for x-ray fluorescence instruments, the range of interest is below 0.2 nm. Also, x-ray fluorescence instruments include an additional non-planar focusing mirror, formed in the same manner as the previously described m The invention described herein was made in the performance of work under contract with the Department of Energy, Contract No. DE-AC04-76DP00789, and the United States Government has rights in the invention pursuant to this contract.

  17. Combined evaluation of grazing incidence X-ray fluorescence and X-ray reflectivity data for improved profiling of ultra-shallow depth distributions.

    Science.gov (United States)

    Ingerle, D; Meirer, F; Pepponi, G; Demenev, E; Giubertoni, D; Wobrauschek, P; Streli, C

    2014-09-01

    The continuous downscaling of the process size for semiconductor devices pushes the junction depths and consequentially the implantation depths to the top few nanometers of the Si substrate. This motivates the need for sensitive methods capable of analyzing dopant distribution, total dose and possible impurities. X-ray techniques utilizing the external reflection of X-rays are very surface sensitive, hence providing a non-destructive tool for process analysis and control. X-ray reflectometry (XRR) is an established technique for the characterization of single- and multi-layered thin film structures with layer thicknesses in the nanometer range. XRR spectra are acquired by varying the incident angle in the grazing incidence regime while measuring the specular reflected X-ray beam. The shape of the resulting angle-dependent curve is correlated to changes of the electron density in the sample, but does not provide direct information on the presence or distribution of chemical elements in the sample. Grazing Incidence XRF (GIXRF) measures the X-ray fluorescence induced by an X-ray beam incident under grazing angles. The resulting angle dependent intensity curves are correlated to the depth distribution and mass density of the elements in the sample. GIXRF provides information on contaminations, total implanted dose and to some extent on the depth of the dopant distribution, but is ambiguous with regard to the exact distribution function. Both techniques use similar measurement procedures and data evaluation strategies, i.e. optimization of a sample model by fitting measured and calculated angle curves. Moreover, the applied sample models can be derived from the same physical properties, like atomic scattering/form factors and elemental concentrations; a simultaneous analysis is therefore a straightforward approach. This combined analysis in turn reduces the uncertainties of the individual techniques, allowing a determination of dose and depth profile of the implanted

  18. Investigation on non-equilibrium x-ray emission spectra from laser produced plasmas

    International Nuclear Information System (INIS)

    Pei Wenbing; Chang Tieqiang; Zhang Jun

    1995-01-01

    A statistical method for the ion configuration probability distribution in non-LTE plasmas based on the average-ion model is described. In this method, the ion configuration probabilities are obtained from the average level population probabilities of the ions according to the binomial distribution. The non-equilibrium ion configuration distribution and X-ray spectra emitted from Au plasmas produced by 1.06 μm laser are studied. The calculated X-ray emission spectra are in the same energy band range as the experimental results. We discuss the non-equilibrium characteristics of X-ray emission, and show that the contributions of the multiply excited ions to X-ray emission are important

  19. First Principles Calculations for X-ray Resonant Spectra and Elastic Properties

    International Nuclear Information System (INIS)

    Yongbin Lee

    2006-01-01

    In this thesis, we discuss applications of first principles methods to x-ray resonant spectra and elastic properties calculation. We start with brief reviews about theoretical background of first principles methods, such as density functional theory, local density approximation (LDA), LDA+U, and the linear augmented plane wave (LAPW) method to solve Kohn-Sham equations. After that we discuss x-ray resonant scattering (XRMS), x-ray magnetic circular dichroism (XMCD) and the branching problem in the heavy rare earths Ledges. In the last chapter we discuss the elastic properties of the second hardest material AlMgB 14

  20. Measuring the angular dependence of betatron x-ray spectra in a laser-wakefield accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pollock, B. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shaw, J. L. [Univ. of California, Los Angeles, CA (United States); Marsh, K. A. [Univ. of California, Los Angeles, CA (United States); Ralph, J. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chen, Y. -H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alessi, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pak, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Clayton, C. E. [Univ. of California, Los Angeles, CA (United States); Glenzer, S. H. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Joshi, C. [Univ. of California, Los Angeles, CA (United States)

    2014-07-22

    This paper presents a new technique to measure the angular dependence of betatron x-ray spectra in a laser-wakefield accelerator. Measurements are performed with a stacked image plates spectrometer, capable of detecting broadband x-ray radiation up to 1 MeV. It can provide measurements of the betatron x-ray spectrum at any angle of observation (within a 40 mrad cone) and of the beam profile. A detailed description of our data analysis is given, along with comparison for several shots. As a result, these measurements provide useful information on the dynamics of the electrons are they are accelerated and wiggled by the wakefield.

  1. The X-ray electronic spectra of TiC-NbC solid solution

    International Nuclear Information System (INIS)

    Cherkashenko, V.M.; Ezhov, A.V.; Nazarova, S.Z.; Kurmaev, Eh.Z.; Nojmann, M.

    2001-01-01

    X-ray photoelectronic spectra of inner levels and valency lands in TiC-NbC solid solutions were studied. Results of combining TiL α -, NbL β2.15 -, CK α - X-ray emission spectra and photoelectronic spectra of valency bands in one energy scale in reference to the Fermi level were analyzed. It is shown that a change in crystal lattice parameters, as well as charge redistribution between titanium and niobium atoms, produce a strong effect on electronic structure formation in the mixed carbides mentioned [ru

  2. SU-F-I-76: Fluoroscopic X-Ray Beam Profiles for Spectra Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.

  3. X-ray spectra for mamography; Espectros de rayos X para mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Ramirez G, J.; Hernandez V, R.; Hernandez D, V.M.; Salas L, M.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico)]. e-mail: fermineutron@yahoo.com

    2008-07-01

    By means of Monte Carlo methods the X-ray spectra that produce Mammography equipment have been obtained. The mammographs are widely used with the purpose of diagnosing the cancer of the mammary glands. Different makers and mammographs models are distinguished by the voltage capacity and the current, exist as well as in the target type and filter. The targets that are used are Mo, Rh and W and the filters are Mo, Rh, Al and Be. In this work the results obtained by means of the MCNP code of the X-ray spectra take place when an electron beam of 28 keV is made impact on Mo, Rh and W targets, as well as the spectra that result of filtering these X rays using different types of filters. The resulting spectra contain the continuous spectrum of the stopping radiation, as well as the X rays characteristic of the used target. The utility of estimating the spectra of X rays by means of Monte Carlo is that it can use to estimate the absorbed dose by the gland, as well as the absorbed dose by other organs. It also allows to calculate the detector response. (Author)

  4. Invisible structures in the X-ray absorption spectra of actinides

    NARCIS (Netherlands)

    Kvashnina, Kristina O.; De Groot, Frank M F

    The X-ray absorption spectra of actinides are discussed with an emphasis on the fundamental effects that influence their spectral shape, including atomic multiplet theory, charge transfer theory and crystal field theory. Many actinide spectra consist of a single peak and it is shown that the use of

  5. Modeling of X-ray Images and Energy Spectra Produced by Stepping Lightning Leaders

    Science.gov (United States)

    Xu, Wei; Marshall, Robert A.; Celestin, Sebastien; Pasko, Victor P.

    2017-11-01

    Recent ground-based measurements at the International Center for Lightning Research and Testing (ICLRT) have greatly improved our knowledge of the energetics, fluence, and evolution of X-ray emissions during natural cloud-to-ground (CG) and rocket-triggered lightning flashes. In this paper, using Monte Carlo simulations and the response matrix of unshielded detectors in the Thunderstorm Energetic Radiation Array (TERA), we calculate the energy spectra of X-rays as would be detected by TERA and directly compare with the observational data during event MSE 10-01. The good agreement obtained between TERA measurements and theoretical calculations supports the mechanism of X-ray production by thermal runaway electrons during the negative corona flash stage of stepping lightning leaders. Modeling results also suggest that measurements of X-ray bursts can be used to estimate the approximate range of potential drop of lightning leaders. Moreover, the X-ray images produced during the leader stepping process in natural negative CG discharges, including both the evolution and morphological features, are theoretically quantified. We show that the compact emission pattern as recently observed in X-ray images is likely produced by X-rays originating from the source region, and the diffuse emission pattern can be explained by the Compton scattering effects.

  6. X-ray Signature of Charge Exchange in the Spectra of L-shell Iron Ions

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P; Schweikhard, L; Liebisch, P; Brown, G V

    2007-01-05

    The X-ray signature of charge exchange between highly charged L-shell iron ions and neutral gas atoms was studied in the laboratory in order to assess its diagnostic utility. Significant differences with spectra formed by electron-impact excitation were observed. In particular, a strong enhancement was found of the emission corresponding to n {le} 4 {yields} n = 2 transitions relative to the n = 3 {yields} n = 2 emission. This enhancement was detectable even with relatively low-resolution X-ray instrumentation (E/{Delta}E {approx} 10) and may enable future identification of charge exchange as a line-formation mechanism in astrophysical spectra.

  7. Fluence thresholds for grazing incidence hard x-ray mirrors

    Czech Academy of Sciences Publication Activity Database

    Aquila, A.; Sobierajski, R.; Ozkan, C.; Hájková, Věra; Burian, Tomáš; Chalupský, Jaromír; Juha, Libor; Störmer, M.; Bajt, S.; Klepka, M.T.; Dlužewski, P.; Morawiec, K.; Ohashi, H.; Koyama, T.; Tono, K.; Inubushi, Y.; Yabashi, M.; Sinn, H.; Tschentscher, T.; Mancuso, A.P.; Gaudin, J.

    2015-01-01

    Roč. 106, č. 24 (2015), "241905-1"-"241905-5" ISSN 0003-6951 R&D Projects: GA ČR(CZ) GA14-29772S Grant - others:AVČR(CZ) M100101221 Institutional support: RVO:68378271 Keywords : XFEL * Free Electron Laser * damage threshold * X-ray optics Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.142, year: 2015

  8. A search for effects on chemical isomerism in muonic X-ray spectra of propyl alcohol

    CERN Document Server

    Brandão d'Oliveira, A; Von Egidy, T

    1974-01-01

    The intensities of muonic X-ray transitions in n-propyl alcohol and isopropyl alcohol were measured. The experiment was performed at the muon channel of the 600 MeV synchrocyclotron at CERN. The spectra were evaluated by means of a standard computer program and by a technique to observe small differences between the propyl-alcohol spectra. No differences in the muonic spectra were observed within rather small experimental errors. (16 refs).

  9. Lifetime-vibrational interference effects in resonantly excited x-ray emission spectra of CO

    Energy Technology Data Exchange (ETDEWEB)

    Skytt, P.; Glans, P.; Gunnelin, K. [Uppsala Univ. (Sweden)] [and others

    1997-04-01

    The parity selection rule for resonant X-ray emission as demonstrated for O{sub 2} and N{sub 2} can be seen as an effect of interference between coherently excited degenerate localized core states. One system where the core state degeneracy is not exact but somewhat lifted was previously studied at ALS, namely the resonant X-ray emission of amino-substituted benzene (aniline). It was shown that the X-ray fluorescence spectrum resulting from excitation of the C1s at the site of the {open_quotes}aminocarbon{close_quotes} could be described in a picture separating the excitation and the emission processes, whereas the spectrum corresponding to the quasi-degenerate carbons could not. Thus, in this case it was necessary to take interference effects between the quasi-degenerate intermediate core excited states into account in order to obtain agreement between calculations and experiment. The different vibrational levels of core excited states in molecules have energy splittings which are of the same order of magnitude as the natural lifetime broadening of core excitations in the soft X-ray range. Therefore, lifetime-vibrational interference effects are likely to appear and influence the band shapes in resonant X-ray emission spectra. Lifetime-vibrational interference has been studied in non-resonant X-ray emission, and in Auger spectra. In this report the authors discuss results of selectively excited soft X-ray fluorescence spectra of molecules, where they focus on lifetime-interference effects appearing in the band shapes.

  10. Many-body effects on the x-ray spectra of metals

    International Nuclear Information System (INIS)

    Satpathy, S.S.

    1982-01-01

    The effects of band structure, of a solid surface, of temperature, and of disorder on the many-electron x-ray spectra of metals are evaluated in a change-of-mean-field approximation using a one-dimensional nearest-neighbor tight-binding model of a metal. The x-ray spectral shapes are determined by both the band structure and the final-state interactions. The effect of the band being non-free-electron-like is not felt at the x-ray threshold, but away from it such effects are noticeable. When the core hole is created at the surface, the spectra at the edge exhibit a Nozieres-de Dominicis-type singularity with the appropriate surface phase-shifts. At energies away from the edge, the one-particle effects are prominent with the x-ray emission and absorption spectra closely reflecting the local one-electron density of states. The recoil spectrum of a Fermi sea at a non-zero temperature has less asymmetry than the zero-temperature case. It was found that at ordinary temperatures the reduction of the asymmetry due to the thermal distribution of one-electron states is not very significant. Finally, using a one-dimensional Anderson model, the effect of lattice disorder on the x-ray absorption spectra is studied for the first time. There are two effects: (1) the strong infrared divergence peak is gradually quenched as disorder is increased, and (2) the threshold is broadened because the threshold energies for absorption at different sites in the crystal depend on the varying local lattice environment. It is proposed that the x-ray spectra may be useful as a tool for studying the degree of electron localization in disordered many-electron systems

  11. Accuracy validation of incident photon fluence on DQE for various measurement conditions and X-ray units.

    Science.gov (United States)

    Haba, Tomonobu; Kondo, Shimpei; Hayashi, Daiki; Koyama, Shuji

    2013-07-01

    Detective quantum efficiency (DQE) is widely used as a comprehensive metric for X-ray image evaluation in digital X-ray units. The incident photon fluence per air kerma (SNR²(in)) is necessary for calculating the DQE. The International Electrotechnical Commission (IEC) reports the SNR²(in) under conditions of standard radiation quality, but this SNR²(in) might not be accurate as calculated from the X-ray spectra emitted by an actual X-ray tube. In this study, we evaluated the error range of the SNR²(in) presented by the IEC62220-1 report. We measured the X-ray spectra emitted by an X-ray tube under conditions of standard radiation quality of RQA5. The spectral photon fluence at each energy bin was multiplied by the photon energy and the mass energy absorption coefficient of air; then the air kerma spectrum was derived. The air kerma spectrum was integrated over the whole photon energy range to yield the total air kerma. The total photon number was then divided by the total air kerma. This value is the SNR²(in). These calculations were performed for various measurement parameters and X-ray units. The percent difference between the calculated value and the standard value of RQA5 was up to 2.9%. The error range was not negligibly small. Therefore, it is better to use the new SNR²(in) of 30694 (1/(mm(2) μGy)) than the current [Formula: see text] of 30174 (1/(mm(2) μGy)).

  12. Probing symmetry and symmetry breaking in resonant soft-x-ray fluorescence spectra of molecules

    Energy Technology Data Exchange (ETDEWEB)

    Glans, P.; Gunnelin, K.; Guo, J. [Uppsala Univ. (Sweden)] [and others

    1997-04-01

    Conventional non-resonant soft X-ray emission brings about information about electronic structure through its symmetry and polarization selectivity, the character of which is governed by simple dipole rules. For centro-symmetric molecules with the emitting atom at the inversion center these rules lead to selective emission through the required parity change. For the more common classes of molecules which have lower symmetry or for systems with degenerate core orbitals (delocalized over identical sites), it is merely the local symmetry selectivity that provides a probe of the local atomic orbital contribution to the molecular orbital. For instance, in X-ray spectra of first row species the intensities essentially map the p-density at each particular atomic site, and, in a molecular orbital picture, the contribution of the local p-type atomic orbitals in the LCAO description of the molecular orbitals. The situation is different for resonant X-ray fluorescence spectra. Here strict parity and symmetry selectivity gives rise to a strong frequency dependence for all molecules with an element of symmetry. In addition to symmetry selectivity the strong frequency dependence of resonant X-ray emission is caused by the interplay between the shape of a narrow X-ray excitation energy function and the lifetime and vibrational broadenings of the resonantly excited core states. This interplay leads to various observable effects, such as linear dispersion, resonance narrowing and emission line (Stokes) doubling. Also from the point of view of polarization selectivity, the resonantly excited X-ray spectra are much more informative than the corresponding non-resonant spectra. Examples are presented for nitrogen, oxygen, and carbon dioxide molecules.

  13. Transmission properties of barite mortar using X-ray spectra measured with Cd Te detector

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J. C.; Mariano, L.; Costa, P. R. [Universidade de Sao Paulo, Instituto de Fisica, Rua do Matao Travessa R. 187, Cidade Universitaria, 05508-090 Sao Paulo (Brazil); Tomal, A., E-mail: josilene@usp.br [Universidade Federal de Goias, Instituto de Fisica, Campus Samambaia, 74001-970 Goiania (Brazil)

    2014-08-15

    Current methods for calculating X-ray shielding barriers do not take into account spectral distribution of the beam transmitted by the protective material. This consideration is important in dose estimations for radiation workers and general public in diagnostic radiology facilities. The aim of the present study was to estimate barite mortar attenuation curves using X-ray spectra weighted by a workload distribution. These curves were described in units of ambient dose equivalent (H (10)), since it is the radiation quantity adopted by IAEA for dose assessment in medical environment. Attenuation curves were determined using the optimized model for shielding evaluation presented by Costa and Caldas (2002). Workload distribution presented by Simpkin (1996), measured primary spectra and mass attenuation coefficients of barite mortar were used as input data in this model. X-ray beams in diagnostic energy range were generated by an industrial X-ray tube with 3 mm of aluminum additional filtration. Primary experimental spectra were measured by a Cd Te detector and corrected by the response function of detector by means of a stripping procedure. Air kerma measurements were performed using an ionization chamber for normalization purpose of the spectra. The corrected spectra presented good agreement with spectra generated by a semi-empirical model. The variation of the ambient dose equivalent as a function of barite mortar thickness was calculated. Using these data, it was estimated the optimized thickness of protective barrier needed for shielding a particular area in an X-ray imaging facility. The results obtained for primary protective barriers exhibit qualitative agreement with those presented in literature. (Author)

  14. X-ray satellite spectra of Ti, V, Cr and Mn induced by photons

    Indian Academy of Sciences (India)

    K X-ray emission spectra of Ti, V, Cr and Mn generated by photon excitation have been studied with a crystal spectrometer. The measured energy shifts of K satellite relative to the diagram line are compared with values obtained by electron excitation and with different theoretical estimates. The present experimental ...

  15. X-ray satellite spectra of Ti, V, Cr and Mn induced by photons

    Indian Academy of Sciences (India)

    Abstract. K X-ray emission spectra of Ti, V, Cr and Mn generated by photon excitation have been studied with a crystal spectrometer. The measured energy shifts of Kα satellite relative to the diagram line are compared with values obtained by electron excitation and with different theoretical estimates. The present ...

  16. Predictions of x-ray scattering spectra in warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Starrett, Charles E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Saumon, Didier [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Souza, Andre N. [Univ. of Michigan, Ann Arbor, MI (United States); Perkins, David J. [Univ. of California, Los Angeles, CA (United States); Hansen, Stephanie B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-03-12

    This presentation gives an Introduction to our model of warm dense matter; How x-ray scattering spectra are calculated from it; Comparisons with experiments: Room temperature/pressure beryllium Warm dense beryllium Warm dense aluminum; Predictions for warm dense beryllium and titanium; and, Conclusions.

  17. A color display device recording X ray spectra, especially intended for medical radiography

    International Nuclear Information System (INIS)

    Boulch, J.-M.

    1975-01-01

    Said invention relates to a color display recording device for X ray spectra intended for medical radiography. The video signal of the X ray camera receiving the radiation having passed through the patient is amplified and transformed into a color coding according to the energy spectrum received by the camera. In a first version, the energy spectrum from the camera gives directly an image on the color tube. In a second version the energy spectrum, after having been transformed into digital signals, is first sent into a memory, then into a computer used as a spectrum analyzer, and finally into the color display device [fr

  18. ROSAT PSPC spectra of X-ray selected narrow emission line galaxies

    Science.gov (United States)

    Colmenero, E. Romero; Carrera, F. J.; Branduardi-Raymont, G.; Mittaz, J. P. D.; McHardy, I. M.; Jones, L. R.

    1996-01-01

    The Rosat Position Sensitive Proportional Counter (PSPC) spectra of a sample of 35 X-ray selected Narrow Emission Line Galaxies (NELGs) are presented. Of these 35 objects, 16 are from the Rosat International X-ray Optical Survey (RIXOS) and the remaining 19 were discovered during the optical identification of Rosat U.K. deep survey sources. A power law model with low energy absorption set at the Galactic value is found to be a good fit for all sources. The results indicate that the spectral slope of NELGs is flatter than that of active galactic nuclei.

  19. The hard X-ray emission spectra from accretion columns in intermediate polars

    Science.gov (United States)

    Yi, Insu; Vishniac, Ethan T.

    1994-01-01

    We consider the hard (greater than 2 keV) X-ray emission from accretion columns in an intermediate polar system, GK Per, using a simple settling solution. The rate of photon emission per logarithmic energy interval can be fitted with a power law, E(exp -gamma), with gamma approximately 2.0, in agreement with observations. This index is only weakly dependent on the mass accretion rate, dot-M, for dot-M in the range of a few times 10(exp 16-18) g/s. The peak energy of the photon spectra (after photoelectric absorption) is expected to be E(sub p) approximately (5 keV) gamma(exp -1/3) (N(sub H)/10(exp 23)/sq cm)(exp 1/3) where N(sub H) is the hydrogen column density along the line of sight. The observed spectra of GK Per and possibly of V1223 Sgr suggest N(sub H) approximately 10(exp 23)/sq cm. This large N(sub H) may be due to partially ionized preshock column material. Alternatively, we also consider absorption by the cool outer parts of an accretion disk. In this case the photoelectric absorption depth in the disk is a sensitive function of inclination. For GK Per the required inclination is approximately 83 deg. For mass accretion rates larger than a critical rate of approximately 10(exp 18) g/s, X-ray emission from the column accretion is significantly affected by radiation drag. Although the mass accretion rate increases dramatically during outbursts, the observed hard (greater than 2 keV) X-ray luminosity will not rise proportionately. The slope and peak energy of the outburst spectra are only weakly affected. We conclude that the observed X-ray spectra can be explained by this simple analytic solution and that the production of hard X-rays from the accretion shock at the magnetic poles in the intermediate polars is in general agreement with the observations. However, since the X-ray emission and absorption depend on the mass accretion rate in a complicated manner, observed hard X-ray luminosities (greater than 2 keV) are not a good indicator of the mass

  20. Spectra transmitted by mortar barite in X-Ray qualities applied in diagnostic radiology as shielding

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Airton T., E-mail: airton.almeida@fundacentro.gov.br [Fundacaoo Jorge Duprat Figueiredo de Seguranca e Medicina do Trabalho (FUNDACENTRO), Belo Horizonte, MG (Brazil); Araujo, F.G.S. [Universidade Federal de Ouro Preto (REDEMAT/UFOP), MG (Brazil); Nogueira, M.S., E-mail: mnogue@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Santos, M.A.P. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2015-07-01

    Concrete which contains water, cement and aggregate, is widely used in building construction such as medical hospitals. The CdZnTe spectrometry system was used to acquire the transmitted spectra in the RQR qualities and the stripping procedure was performed by taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined. The samples were prepared in rectangular plate format with dimensions of (5 x 5) cm with thicknesses varying from 0.2cm to 2cm and exposed to x-ray beams generated. The HVL and the mean energy in this energy range was determined. (author)

  1. Analysis of neon soft x-ray spectra from short-pulse laser-produced plasmas

    International Nuclear Information System (INIS)

    Abare, A.C.; Keane, C.J.; Crane, J.K.; DaSilva, L.B.; Lee, R.W.; Perry, M.D.; Falcone, R.W.

    1993-04-01

    We report preliminary results from the analysis of streaked soft x-ray neon spectra a gas jet target. In obtained from the interaction of a picosecond Nd:glass laser with these experiments streaked spectra show prompt harmonic emission followed by longer time duration soft x-ray line emission. The majority of the line emission observed was found to originate from Li- and Be-like Ne and the major transitions in the observed spectra have been identified. Li-like emission lines were observed to decay faster in time than Be-like transitions, suggesting that recombination is taking place. Line ratios of n=4-2 and n=3-2 transitions supported the view that these lines were optically thin and thick, respectively. The time history of Li-like Ne 2p-4d and 2p-3d lines is in good agreement with a simple adiabatic expansion model coupled to a time dependent collisional-radiative code. Further x-ray spectroscopic analysis is underway which is aimed at diagnosing plasma conditions and assessing the potential of this recombining neon plasma as a quasi-steady-state recombination x-ray laser medium

  2. Soft x ray emission spectra from laser-irradiated high-Z targets

    Science.gov (United States)

    Mehlman, G.; Burkhalter, P. G.; Newman, D. A.; Ripin, B. H.

    1990-06-01

    X ray data were acquired from mass-limited targets with the Pharos III laser system. Targets, mounted at the tip of thin glass stalks, were microscopic pieces of single or multiple high-Z element composition. The laser irradiance was 4 x 10(exp 14) W/sq cm with about 300J of focused 1.05 microns wavelength laser beam. A convex KAP crystal spectrograph was used for its capability to collect high resolution spectra in the 4 to 20 A soft x ray region. The recorded spectral film densities were microdensitometered and converted by computer-processing to absolute continuum and emission line intensities. The spectral features were identified with the aid of ab-initio atomic structure calculations. The continuum background was evaluated as a source of pseudo-continua for absorption studies of soft x rays.

  3. Modeling of the EUV and X-Ray Emission Spectra Induced by the Solar Winds Ions in the Heliosphere

    Science.gov (United States)

    Kharchenko, Vasili

    2005-01-01

    We have carried out investigation of the EUV and X-ray emission spectra induced in interaction between the Solar Wind (SW) and interstellar neutral gas. The spectra of most important SW ions have been computed for the charge-exchange mechanism of X-ray emission using new accurate spectroscopic data from recent laboratory measurements and theoretical calculations. Total spectra have been constructed as a sum of spectra induced in the charge-exchange collisions by individual O(exp q+), C(exp q+), N(exp q+), Ne(exp q+), Mg (exp q+) and Fe(exp q+) ions. Calculations have been performed for X-ray emission from the heliospheric hydrogen and helium gas. X-ray maps of the heliosphere have been computed. The power density of X-ray sources in the heliospheric ecliptic plane is shown for the H gas and for the He gas. Distances from the Sun (0,0) are given in AU. The helium cone is clear seen in the X-ray map of the charge-exchange emission induced by the solar wind. X-ray emission spectra detected by the Chandra X-ray telescope from the "dark" side of Moon has been identified as a X-ray background emission induced by the solar wind from the geocorona. Spectra and intensities of this charge-exchange X-rays have been compared with the heliospheric component of the X-ray background. Observations and modeling of the SW spectra induced from the geocorona indicate a strong presence of emission lines of highly charged oxygen ions. Anisotropy in distribution of heliospheric X-rays has been predicted and calculated for the regions of the fast and slow solar winds.

  4. Theoretical modeling of Comptonized X-ray spectra of super-Eddington accretion flow: Origin of hard excess in ultraluminous X-ray sources

    Science.gov (United States)

    Kitaki, Takaaki; Mineshige, Shin; Ohsuga, Ken; Kawashima, Tomohisa

    2017-12-01

    X-ray continuum spectra of super-Eddington accretion flow are studied by means of Monte Carlo radiative transfer simulations based on the radiation hydrodynamic simulation data, in which both thermal- and bulk-Compton scatterings are taken into account. We compare the calculated spectra of accretion flow around black holes with masses of MBH = 10, 102, 103, and 104 M⊙ for a fixed mass injection rate (from the computational boundary at 103 rs) of 103 LEdd/c2 (with rs, LEdd, and c being the Schwarzschild radius, the Eddington luminosity, and the speed of light, respectively). The soft X-ray spectra exhibit mass dependence in accordance with the standard-disk relation; the maximum surface temperature is scaled as T ∝ M_{ BH}^{ -1/4}. The spectra in the hard X-ray band, by contrast with soft X-ray, look to be quite similar among different models, if we normalize the radiation luminosity by MBH. This reflects that the hard component is created by thermal- and bulk-Compton scatterings of soft photons originating from an accretion flow in the overheated and/or funnel regions, the temperatures of which have no dependence on mass. The hard X-ray spectra can be reproduced by a Wien spectrum with the temperature of T ˜ 3 keV accompanied by a hard excess at photon energy above several keV. The excess spectrum can be fitted well with a power law with a photon index of Γ ˜ 3. This feature is in good agreement with that of the recent NuSTAR observations of ULXs (ultra-luminous X-ray sources).

  5. Dynamical and Radiative Properties of X-Ray Pulsar Accretion Columns: Phase-averaged Spectra

    Energy Technology Data Exchange (ETDEWEB)

    West, Brent F. [Department of Electrical and Computer Engineering, United States Naval Academy, Annapolis, MD (United States); Wolfram, Kenneth D. [Naval Research Laboratory (retired), Washington, DC (United States); Becker, Peter A., E-mail: bwest@usna.edu, E-mail: kswolfram@gmail.com, E-mail: pbecker@gmu.edu [Department of Physics and Astronomy, George Mason University, Fairfax, VA (United States)

    2017-02-01

    The availability of the unprecedented spectral resolution provided by modern X-ray observatories is opening up new areas for study involving the coupled formation of the continuum emission and the cyclotron absorption features in accretion-powered X-ray pulsar spectra. Previous research focusing on the dynamics and the associated formation of the observed spectra has largely been confined to the single-fluid model, in which the super-Eddington luminosity inside the column decelerates the flow to rest at the stellar surface, while the dynamical effect of gas pressure is ignored. In a companion paper, we have presented a detailed analysis of the hydrodynamic and thermodynamic structure of the accretion column obtained using a new self-consistent model that includes the effects of both gas and radiation pressures. In this paper, we explore the formation of the associated X-ray spectra using a rigorous photon transport equation that is consistent with the hydrodynamic and thermodynamic structure of the column. We use the new model to obtain phase-averaged spectra and partially occulted spectra for Her X-1, Cen X-3, and LMC X-4. We also use the new model to constrain the emission geometry, and compare the resulting parameters with those obtained using previously published models. Our model sheds new light on the structure of the column, the relationship between the ionized gas and the photons, the competition between diffusive and advective transport, and the magnitude of the energy-averaged cyclotron scattering cross-section.

  6. X-ray fluorescence analysis of thin films at glancing-incident and -takeoff angles

    International Nuclear Information System (INIS)

    Tsuji, K.; Sato, S.; Hirokawa, K.

    1995-01-01

    We have developed a new analytical method, Glancing-Incidence and -Takeoff X-Ray Fluorescence (GIT-XRF) method for the first time. Here, we present an idea for a thin-film analysis and a surface analysis by the GIT-XRF method. In this method, the dependence of the fluorescent x-ray intensity on takeoff angle is measured at various incident angles of the primary x-ray. Compared with a total reflection x-ray fluorescence method, the GIT-XRF method allows a detailed thin-film analysis, because the thin film is cross-checked by many experimental curves. Moreover, a surface-sensitive analysis is also possible by the GIT-XRF method. (author)

  7. X ray spectra and qualities for use in diagnostic radiology and equipment calibration

    International Nuclear Information System (INIS)

    Souza, Karla Cristina de

    1996-12-01

    The goal of this work was the standardization of radiation qualities of diagnostic X ray equipment of the Assay Laboratory of the Institute for Radiation Protection and Dosimetry (IRD) of the National Commission of Nuclear Energy, Brazil. X ray spectra were determined from pulse height distribution measured directly on the primary beam using a high pure planar Ge detector. A program was developed to convert pulse height distribution into radiation spectra in the range from 20 to 150 keV. X ray qualities based on those used by the 'Physikalish-Technish Bundesantalt' (PTB) primary laboratory were implanted in three radiological equipment of the Assay Laboratory. These qualities simulate radiation beams on patients submitted to typical radiological examinations. Besides the spectrometric system, a reference measurement system based on an ionization chamber calibrated in air kerma was used to establish parameters such as kilovoltage, first and second half-value layer, mean energy, effective energy and inherent filtration. Our data have shown that the implantation of these radiation qualities in the Assay Laboratory results on a metrological basis for calibration of dose measurement assemblies and kV-meters, like those used by IRD to evaluate the parameters of X ray equipment around the country. A catalogue of spectral data resulting from this work is a data bank that allows various applications like dose calculation using Monte Carlo simulation techniques. (author)

  8. Modeling X-ray Spectra of Astrophysical Plasmas: Current Status and Future Needs

    Science.gov (United States)

    Smith, Randall

    Existing high-resolution astrophysical X-ray spectra has exposed the need for high-quality atomic data of all stripes: wavelengths, collisional and absorption cross sections, and radiative rates. The Astro-H soft X-ray spectrometer (2015 launch) will vastly increase the number and type of high-resolution X-ray spectra available and likely expose a number of shortcomings in our models. I will describe recent advances in theoretical calculations and laboratory measurements, as well as a number of existing needs in the field. These include accurate soft X-ray wavelengths for L-shell ions, diagnostic emission line ratios with estimated error bars, and high-resolution absorption cross sections for abundant ions and molecules. Finally, new models of emission from non-equilibrium ionization plasmas and astrophysical charge exchange will be discussed. This latter emission arises due to the interaction of highly charged ions with neutral atoms, forming a diffuse background in the case of solar wind ions and possibly also arising in more distant environments.

  9. Automated generation and ensemble-learned matching of X-ray absorption spectra

    Science.gov (United States)

    Zheng, Chen; Mathew, Kiran; Chen, Chi; Chen, Yiming; Tang, Hanmei; Dozier, Alan; Kas, Joshua J.; Vila, Fernando D.; Rehr, John J.; Piper, Louis F. J.; Persson, Kristin A.; Ong, Shyue Ping

    2018-03-01

    X-ray absorption spectroscopy (XAS) is a widely used materials characterization technique to determine oxidation states, coordination environment, and other local atomic structure information. Analysis of XAS relies on comparison of measured spectra to reliable reference spectra. However, existing databases of XAS spectra are highly limited both in terms of the number of reference spectra available as well as the breadth of chemistry coverage. In this work, we report the development of XASdb, a large database of computed reference XAS, and an Ensemble-Learned Spectra IdEntification (ELSIE) algorithm for the matching of spectra. XASdb currently hosts more than 800,000 K-edge X-ray absorption near-edge spectra (XANES) for over 40,000 materials from the open-science Materials Project database. We discuss a high-throughput automation framework for FEFF calculations, built on robust, rigorously benchmarked parameters. FEFF is a computer program uses a real-space Green's function approach to calculate X-ray absorption spectra. We will demonstrate that the ELSIE algorithm, which combines 33 weak "learners" comprising a set of preprocessing steps and a similarity metric, can achieve up to 84.2% accuracy in identifying the correct oxidation state and coordination environment of a test set of 19 K-edge XANES spectra encompassing a diverse range of chemistries and crystal structures. The XASdb with the ELSIE algorithm has been integrated into a web application in the Materials Project, providing an important new public resource for the analysis of XAS to all materials researchers. Finally, the ELSIE algorithm itself has been made available as part of veidt, an open source machine-learning library for materials science.

  10. A method to unfold the efficiency of gaseous detectors exposed to broad X-ray spectra

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Souza, Maria Ines S. de; Lopes, Ricardo T.

    2000-01-01

    A method to obtain the efficiency of a gaseous detector exposed to broad energy X-ray spectra was developed. It consists in the de-convolution of the integrated detector response using the shapes of those spectra as a tool to unfold the aimed detector efficiency curve. For this purpose, the spectra emitted by a X-ray tube under several anode voltages, were properly characterized through measurements with a NaI(Tl) spectrometer. A Lorentz function was then fitted to each of the spectra, and their parameters expressed as a function of the anode voltage, by using polynomial and gaussian fittings. The integral of the product of each Lorentz function, by another unknown Lorentz function, expressing the detector efficiency curve, represents the response of the detector for each anode tension, e.g., each X-ray spectrum. The symbolical integration of that product, produces a general function containing the unknown parameters of the unknown efficiency curve. A non-linear fitting of this general function, to the detector response points, as experimentally obtained, generates the aimed parameters for the efficiency curve. The final detector efficiency curve is obtained after normalization procedures. (author)

  11. New Chandra observations of the jet in 3C273. 1. Softer X-ray than radio spectra and the X-ray emission mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Jester, Sebastian; /Fermilab; Harris, D.E.; /Smithsonian Astrophys. Observ.; Marshall, H.L.; /MIT, MKI; Meisenheimer, K.; /Heidelberg, Max Planck Inst. Astron.

    2006-05-01

    The jet in 3C273 is a high-power quasar jet with radio, optical and X-ray emission whose size and brightness allow a detailed study of the emission processes acting in it. We present deep Chandra observations of this jet and analyze the spectral properties of the jet emission from radio through X-rays. We find that the X-ray spectra are significantly softer than the radio spectra in all regions of the bright part of the jet except for the first bright ''knot A'', ruling out a model in which the X-ray emission from the entire jet arises from beamed inverse-Compton scattering of cosmic microwave background photons in a single-zone jet flow. Within two-zone jet models, we find that a synchrotron origin for the jet's X-rays requires fewer additional assumptions than an inverse-Compton model, especially if velocity shear leads to efficient particle acceleration in jet flows.

  12. Description of x-ray tube spectra by the depth distribution function of Pouchou and Pichoir

    International Nuclear Information System (INIS)

    Schobmann, B.; Wernisch, J.; Ebel, H.

    1995-01-01

    We have developed an algorithm for calculating the x-ray tube continuum based on the depth distribution function (DDF) proposed by Pochou and Pichoir, extended the description of white and characteristic radiation given by Wiederschwinger et al to the low energy range from 5 to 30 keV and compared the results from these algorithms to the signals obtained from algorithms using the absorption correction of Philibert and of Sewell et al. Preceding calculations the measured spectra were separated into characteristic peak spectra and into the corresponding white spectra, where the background below the peak areas was numerically interpolated. 13 refs., 5 figs

  13. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source.

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ∼95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ∼6.0%.

  14. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ˜95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ˜6.0%.

  15. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Paixao, L.; Oliveira, B. B.; Nogueira, M. do S. [Centro de Desenvolvimento da Tecnologia Nuclear, Post-graduation in Science and Technology of Radiations, Minerals and Materials, Pte. Antonio Carlos 6.627, Pampulha, 31270-901 Belo Horizonte (Brazil); Viloria, C. [UFMG, Departamento de Engenharia Nuclear, Post-graduation in Nuclear Sciences and Techniques, Pte. Antonio Carlos 6.627, Pampulha, 31270-901 Belo Horizonte (Brazil); Alves de O, M. [UFMG, Department of Anatomy and Imaging, Prof. Alfredo Balena 190, 30130-100 Belo Horizonte (Brazil); Araujo T, M. H., E-mail: lpr@cdtn.br [Dr Maria Helena Araujo Teixeira Clinic, Guajajaras 40, 30180-100 Belo Horizonte (Brazil)

    2014-08-15

    It is widely accepted that the mean glandular dose (D{sub G}) for the glandular tissue is the more useful magnitude for characterizing the breast cancer risk. The procedure to estimate the D{sub G}, for being difficult to measure it directly in the breast, it is to make the use of conversion factors that relate incident air kerma (K{sub i}) at this dose. Generally, the conversion factors vary with the x-ray spectrum half-value layer and the breast composition and thickness. Several authors through computer simulations have calculated such factors by the Monte Carlo (Mc) method. Many spectral models for D{sub G} computer simulations purposes are available in the diagnostic range. One of the models available generates unfiltered spectra. In this work, the Monte Carlo EGSnrc code package with the C++ class library (eg spp) was employed to derive filtered tungsten x-ray spectra used in digital mammography systems. Filtered spectra for rhodium and aluminium filters were obtained for tube potentials between 26 and 32 kV. The half-value layer of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F and Mam Detector Platinum and 8201023-C Xi Base unit Platinum Plus w m As in a Hologic Selenia Dimensions system using a Direct Radiography mode. Calculated half-value layer values showed good agreement compared to those obtained experimentally. These results show that the filtered tungsten anode x-ray spectra and the EGSnrc Mc code can be used for D{sub G} determination in mammography. (Author)

  16. Grazing Incidence X-ray Scattering and Diffraction

    Indian Academy of Sciences (India)

    IAS Admin

    tion between the incident plane wave and the medium is sufficiently weak, then the first Born approximation, can be applied. In this approximation, the scattered wave function ψ(r ) can be assumed to be the same as the incident plane wave and hence the scattering amplitude takes a simpler form f(kf ,ki) = ∫ dr ϱ(r )e iq.r.

  17. Production of X-ray transition radiation with relativistic electrons propagating at grazing incidence

    CERN Document Server

    Couillaud, C

    2002-01-01

    This paper is concerned with the production of X-ray transition radiation when a relativistic electron crosses the interface between two media of different permittivities at the grazing incidence. The production yields are derived analytically when a thick interface is considered and are compared with those obtained when the electron crosses the interface at normal incidence. The production of X-ray photons having an energy between two photoabsorption edges or close to a photoabsorption edge is also investigated. The main features of the transition radiation produced are then exhibited and it is shown that the intensity can be increased by many orders of magnitude. We also show that, at grazing incidence, the backward transition radiation has an intensity close to the forward emission one, contrary to the normal incidence case. The production of quasi-monochromatic radiation is also presented. Finally, the production of X-ray transition radiation using a multilayer radiator is considered and compared in both ...

  18. Introduction to the theory of X-ray and electronic spectra of free atoms

    CERN Document Server

    Karazija, Romas

    1996-01-01

    Covering both theory and applications, this important work provides a comprehensive introduction to the modern theory of X-ray and electronic spectra of free atoms Romas Karazija discusses methods of angular momenta, irreducible tensorial operators, and coefficients of fractional parentage and their use in determining cross sections and probabilities of elementary processes In addition, Karazija addresses the structure of electronic shells with inner vacancies and many-body effects

  19. Differential Deposition for Surface Figure Corrections in Grazing Incidence X-Ray Optics

    Science.gov (United States)

    Ramsey, Brian D.; Kilaru, Kiranmayee; Atkins, Carolyn; Gubarev, Mikhail V.; Broadway, David M.

    2015-01-01

    Differential deposition corrects the low- and mid- spatial-frequency deviations in the axial figure of Wolter-type grazing incidence X-ray optics. Figure deviations is one of the major contributors to the achievable angular resolution. Minimizing figure errors can significantly improve the imaging quality of X-ray optics. Material of varying thickness is selectively deposited, using DC magnetron sputtering, along the length of optic to minimize figure deviations. Custom vacuum chambers are built that can incorporate full-shell and segmented Xray optics. Metrology data of preliminary corrections on a single meridian of full-shell x-ray optics show an improvement of mid-spatial frequencies from 6.7 to 1.8 arc secs HPD. Efforts are in progress to correct a full-shell and segmented optics and to verify angular-resolution improvement with X-ray testing.

  20. Design of grazing-incidence multilayer supermirrors for hard-X-ray reflectors

    DEFF Research Database (Denmark)

    Joensen, K. D.; Voutov, P.; Szentgyorgyi, A.

    1995-01-01

    -X-ray reflector and a hard-X-ray telescope) shows that an improved performance can be obtained. A multilayer whose bilayer thicknesses are given by a power law expression is found to provide the best solution; however, it is only slightly better than some of the adapted neutron designs......Extremely broadband grazing-incidence multilayers for hard-X-ray reflection can be obtained by a gradual change of the layer thicknesses down through the structure. Existing approaches for designing similar neutron optics, called supermirrors, are shown to provide respectable performance when...... applied to X-ray multilayers. However, none of these approaches consider the effects of imperfect layer interfaces and absorption in the overlying layers. Adaptations of neutron designs that take these effects into account are presented, and a thorough analysis of two specific applications (a single hard...

  1. The Broadband XMM-Newton and NuSTAR X-ray Spectra of Two Ultraluminous X-ray Sources in the Galaxy IC 342

    DEFF Research Database (Denmark)

    Rana, Vikram; Harrison, Fiona A.; Bachetti, Matteo

    2015-01-01

    We present results for two Ultraluminous X-ray Sources (ULXs), IC 342 X-1 and IC 342 X-2, using two epochs of XMM-Newton and NuSTAR observations separated by ∼7 days. We observe little spectral or flux variability above 1 keV between epochs, with unabsorbed 0.3-30 keV luminosities being $1...... ULXs exhibit strong curvature in their broadband X-ray spectra. This curvature rules out models that invoke a simple reflection-dominated spectrum with a broadened iron line and no cutoff in the illuminating power-law continuum. X-ray spectrum of IC 342 X-1 can be characterized by a soft disk...

  2. X-ray grazing incidence diffraction from multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Tixier, S.; Boeni, P.; Swygenhoven, H. van; Horisberger, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Grazing incidence scattering geometries using synchrotron radiation have been applied in order to characterise the roughness profiles and the structural coherence of multilayers. The lateral correlation length of the roughness profiles was evaluated using diffuse reflectivity in the `out of plane` geometry. This type of measurement is the only diffuse reflectivity technique allowing large lateral momentum transfer. It is typically suitable for correlation lengths smaller than 1000 A. The lateral structural coherence length of Ni{sub 3}Al/Ni multilayers as a function of the layer thickness was obtained by grazing incidence diffraction (GID). 3 figs., 1 ref.

  3. Molecular-orbital studies via satellite-free x-ray fluorescence: Cl K absorption and K--valence-level emission spectra of chlorofluoromethanes

    International Nuclear Information System (INIS)

    Perera, R.C.C.; Cowan, P.L.; Lindle, D.W.; LaVilla, R.E.; Jach, T.; Deslattes, R.D.

    1991-01-01

    X-ray absorption and emission measurements in the vicinity of the chlorine K edge of the three chlorofluoromethanes have been made using monochromatic synchrotron radiation as the source of excitation. By selectively tuning the incident radiation to just above the Cl 1s single-electron ionization threshold for each molecule, less complex x-ray-emission spectra are obtained. This reduction in complexity is attributed to the elimination of multielectron transitions in the Cl K shell, which commonly produce satellite features in x-ray emission. The resulting ''satellite-free'' x-ray-emission spectra exhibit peaks due only to electrons in valence molecular orbitals filling a single Cl 1s vacancy. These simplified emission spectra and the associated x-ray absorption spectra are modeled using straightforward procedures and compared with semiempirical ground-state molecular-orbital calculations. Good agreement is observed between the present experimental and theoretical results for valence-orbital energies and those obtained from ultraviolet photoemission, and between relative radiative yields determined both experimentally and theoretically in this work

  4. X-RAY REFLECTED SPECTRA FROM ACCRETION DISK MODELS. I. CONSTANT DENSITY ATMOSPHERES

    International Nuclear Information System (INIS)

    Garcia, J.; Kallman, T. R.

    2010-01-01

    We present new models for illuminated accretion disks, their structure, and reprocessed emission. We consider the effects of incident X-rays on the surface of an accretion disk by simultaneously solving the equations of radiative transfer, energy balance, and ionization equilibrium over a large range of column densities. We assume plane-parallel geometry and azimuthal symmetry, such that each calculation corresponds to a ring at a given distance from the central object. Our models include recent and complete atomic data for K-shell processes of the iron and oxygen isonuclear sequences. We examine the effect on the spectrum of fluorescent Kα line emission and absorption in the emitted spectrum. We also explore the dependence of the spectrum on the strength of the incident X-rays and other input parameters, and discuss the importance of Comptonization on the emitted spectrum.

  5. X-ray Reflected Spectra from Accretion Disk Models. I. Constant Density Atmospheres

    Science.gov (United States)

    Garcia, Javier; Kallman, Timothy R.

    2009-01-01

    We present new models for illuminated accretion disks, their structure and reprocessed emission. We consider the effects of incident X-rays on the surface of an accretion disk by solving simultaneously the equations of radiative transfer, energy balance and ionization equilibrium over a large range of column densities. We assume plane-parallel geometry and azimuthal symmetry, such that each calculation corresponds to a ring at a given distance from the central object. Our models include recent and complete atomic data for K-shell of the iron and oxygen isonuclear sequences. We examine the effect on the spectrum of fluorescent Ka line emission and absorption in the emitted spectrum. We also explore the dependence of the spectrum on the strength of the incident X-rays and other input parameters, and discuss the importance of Comptonization on the emitted spectrum.

  6. Modelling of the soft X-ray tungsten spectra expected to be registered by GEM detection system for WEST

    Directory of Open Access Journals (Sweden)

    Syrocki Łukasz

    2016-12-01

    Full Text Available In the future International Thermonuclear Experimental Reactor (ITER, the interaction between the plasma and the tungsten chosen as the plasma-facing wall material imposes that the hot central plasma loses energy by X-ray emission from tungsten ions. On the other hand, the registered X-ray spectra provide alternative diagnostics of the plasma itself. Highly ionized tungsten emits extremely complex X-ray spectra that can be understood only after exhaustive theoretical studies. The detailed analyses will be useful for proper interpretation of soft X-ray plasma radiation expected to be registered on ITER-like machines, that is, Tungsten (W Environment in Steady-state Tokamak (WEST. The simulations of the soft X-ray spectra structures for tungsten ions have been performed using the flexible atomic code (FAC package within the framework of collisional-radiative (CR model approach for electron temperatures and densities relevant to WEST tokamak.

  7. Accurate modeling of benchmark x-ray spectra from highly charged ions of tungsten

    International Nuclear Information System (INIS)

    Ralchenko, Yuri; Tan, Joseph N.; Gillaspy, J. D.; Pomeroy, Joshua M.; Silver, Eric

    2006-01-01

    We present detailed collisional-radiative modeling for a benchmark x-ray spectrum of highly charged tungsten ions in the range between 3 and 10 A ring produced in an electron beam ion trap (EBIT) with a beam energy of 4.08 keV. Remarkably good agreement between calculated and measured spectra was obtained without adjustable parameters, highlighting the well-controlled experimental conditions and the sophistication of the kinetic simulation of the non-Maxwellian tungsten plasma. This agreement permitted the identification of spectral lines from Cu-like W 45+ and Ni-like W 46+ ions, led to the reinterpretation of a previously known line in Ni-like ion as an overlap of electric-quadrupole and magnetic-octupole lines, and revealed subtle features in the x-ray spectrum arising from the dominance of forbidden transitions between excited states. The importance of level population mechanisms specific to the EBIT plasma is discussed as well

  8. Investigation of temperature dependence of muonic X-ray spectra structure in silicon and vanadium oxides

    International Nuclear Information System (INIS)

    Andreeff, A.; Evseev, V.S.; Minkova, A.; Ortlepp, H.-G.; Roganov, V.S.; Rybakov, V.N.; Sabirov, B.M.; Fromm, W.

    1979-01-01

    To study the influence of matter macroscopic properties on the negative muon atomic capture the muonic X-ray spectra have been measured from silicon at 77 deg and 295 deg, from VO 2 at 295 deg and 355 deg, and from V 2 O 3 at 77 deg and 295 deg using a Ge(Li) spectrometer 55 cm 3 in volume and ''on-line'' technique. It is shown that neither changes of a conductivity in all targets, nor a rebuilding of both vanadium oxydes crystal structure at phase transition does not cause any alteration in muonic X-ray spectrum. The obtained results are discussed in terms of a ''time pit''

  9. Solar quiescent Active Region temperature distribution inferred from the Miniature Solar X-ray Solar Spectrometer (MinXSS) CubeSat soft X-ray spectra, Hinode X-ray Telescope (XRT) soft X-ray filter images and EUV measurements.

    Science.gov (United States)

    Moore, C. S.; Woods, T. N.; Caspi, A.; Mason, J. P.

    2016-12-01

    Soft X-rays serve as an important diagnostic tool for hot (T > 106 K) solar coronal plasma elemental composition, elemental ionization states, density of emitting plasma and dynamical events triggered by magnetic field structures. Spectrally resolved, solar disc averaged, soft X-ray spectra from the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat combined with spatially resolved soft X-ray filter images from the Hinode X-ray Telescope (XRT) and complimentary EUV data can yield unique inferences of the quiescent (non-flaring) active regions' emitting plasma temperature distribution and chemical composition. This talk will discuss how the MinXSS spectra and Hinode XRT images from the sparsely measured 0.7 - 10 keV ( 0.124 - 1.77 nm) region, can augment estimations of active region temperature distribution and elemental abundance variations that are currently being assessed primarily from typical EUV and hard X-ray observations.

  10. Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector

    International Nuclear Information System (INIS)

    Birch, R.; Marshall, M.

    1979-01-01

    A method of computing theoretical X-ray spectra in the range 30 to 150 kV is presented. The theoretical spectra have been compared with constant potential, high resolution spectra from a tungsten target measured with a Ge(Li) detector, for a range of target angles, tube voltage and filtrations. Above 100 kV the spectra were also measured with a NaI detector but, as there was good agreement between the Ge(Li) and NaI detectors, only the former are presented. Spectra computed using Kramers' theory are also included for comparison, giving fairly good agreement at large target angles (30 0 ) but becoming gradually worse as the target angle decreased. Spectra may be computed by this method for any desired filtration, target angle, and tube voltage between 30 and 150 kV, in excellent agreement with the measured data. (author)

  11. Laboratory Studies of X-ray Spectra Formed by Charge Exchange

    Science.gov (United States)

    Beiersdorfer, Peter; Ali, R.; Brown, G. V.; Koutroumpa, D.; Kelley, R. L.; Kilbourne, C.; Leutenegger, M. A.; Porter, F.

    2013-04-01

    Charge exchange between ions and neutral atoms or molecules has been accepted at an important soft producing process in our solar system. By extension, charge exchange may contribute to the X-ray emission of circumstellar material. It may also produce X-ray emission at the boundaries of supernova ejecta and star burst galaxies, or whenever hot plasma collides with neutral matter. X-ray spectra of K-shell and L-shell ions formed by charge exchange have now been studied in a variety of laboratory settings. These experiments have shown several characteristic features of line formation by charge exchange when compared to the X-ray emission produced by electron-impact excitation, e.g., enhancement emission of forbidden lines and of lines from levels with high principal quantum number. They have also shown a dependence on the interaction gas and on the energy of the ion-neutral collision. Moreover, the transfer of multiple electrons is typically preferred, provided the donor molecules or atoms have multiple valence-shell electrons. The laboratory measurements are in qualitative agreement with theory. However, the details of the observed X-ray spectra, especially those recorded with high spectral resolution, can differ substantially from predictions, especially for spectra produced at collision velocities equal to or lower than those found in thermal plasmas or produced with neutral gases other than atomic hydrogen. Puzzling discrepancies can be noted, such as enhanced emission from an upper level with the 'wrong' principal quantum number. Even more puzzling is a recent experiment in which two, co-mixed bare ion species of similar atomic number produce very different Lyman series emission upon charge exchange with a given neutral gas, defying both theoretical predictions and empirical scaling. Laboratory measurements have also shown that some of the characteristic features of charge exchange can be reproduced by radiative electron capture, i.e., by capture of a continuum

  12. The influence of magnetic field geometry on magnetars X-ray spectra

    International Nuclear Information System (INIS)

    Viganò, D; Pons, J A; Miralles, J A; Parkins, N; Zane, S; Turolla, R

    2012-01-01

    Nowadays, the analysis of the X-ray spectra of magnetically powered neutron stars or magnetars is one of the most valuable tools to gain insight into the physical processes occurring in their interiors and magnetospheres. In particular, the magnetospheric plasma leaves a strong imprint on the observed X-ray spectrum by means of Compton up-scattering of the thermal radiation coming from the star surface. Motivated by the increased quality of the observational data, much theoretical work has been devoted to develop Monte Carlo (MC) codes that incorporate the effects of resonant Compton scattering (RCS) in the modeling of radiative transfer of photons through the magnetosphere. The two key ingredients in this simulations are the kinetic plasma properties and the magnetic field (MF) configuration. The MF geometry is expected to be complex, but up to now only mathematically simple solutions (self-similar solutions) have been employed. In this work, we discuss the effects of new, more realistic, MF geometries on synthetic spectra. We use new force-free solutions [14] in a previously developed MC code [9] to assess the influence of MF geometry on the emerging spectra. Our main result is that the shape of the final spectrum is mostly sensitive to uncertain parameters of the magnetospheric plasma, but the MF geometry plays an important role on the angle-dependence of the spectra.

  13. Changes in X-ray photoelectron spectra of yttria-tetragonal zirconia polycrystal by ion sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Eiko; Yoshinari, Masao [Tokyo Dental College, Oral Health Science Center, Tokyo, Chiyoda-ku (Japan)

    2016-04-15

    This paper reports changes in X-ray photoelectron spectroscopy spectra of yttria-tetragonal zirconia polycrystal (Y-TZP) brought about by Ar ion sputtering. The changes in the core-level spectra of Y-TZP suggest that preferential sputtering of oxygen occurred. A new peak was observed near 0 eV binding energy accompanied with changes in the core-level spectra by the sputtering. After 18 h in a high vacuum following the sputtering, the spectra changed by the sputtering were returned to their original shapes. In contrast, the color of Y-TZP was changed from white to pale brown by X-ray irradiation and was changed from pale brown to dark gray by ion sputtering. However, when the new peak near 0 eV decreased after 18 h, no color change was observed. Therefore, it is thought that the new peak was mainly derived from electrons trapped in various kinds of oxygen vacancies created by the sputtering in other than color centers. (orig.)

  14. Precise material identification method based on a photon counting technique with correction of the beam hardening effect in X-ray spectra

    International Nuclear Information System (INIS)

    Kimoto, Natsumi; Hayashi, Hiroaki; Asahara, Takashi; Mihara, Yoshiki; Kanazawa, Yuki; Yamakawa, Tsutomu; Yamamoto, Shuichiro; Yamasaki, Masashi; Okada, Masahiro

    2017-01-01

    The aim of our study is to develop a novel material identification method based on a photon counting technique, in which the incident and penetrating X-ray spectra are analyzed. Dividing a 40 kV X-ray spectra into two energy regions, the corresponding linear attenuation coefficients are derived. We can identify the materials precisely using the relationship between atomic number and linear attenuation coefficient through the correction of the beam hardening effect of the X-ray spectra. - Highlights: • We propose a precise material identification method to be used as a photon counting system. • Beam hardening correction is important, even when the analysis is applied to the short energy regions in the X-ray spectrum. • Experiments using a single probe-type CdTe detector were performed, and Monte Carlo simulation was also carried out. • We described the applicability of our method for clinical diagnostic X-ray imaging in the near future.

  15. Absorbed dose determination using experimental and analytical predictions of x-ray spectra

    Science.gov (United States)

    Edwards, David Lee

    1999-10-01

    Electron beam welding in a vacuum is a technology that NASA is investigating as a joining technique for manufacture of space structures. The interaction of energetic electrons with metal produces x-rays. This investigation characterizes the x-ray environment due to operation of an in-vacuum electron beam welding tool and provides recommendations for adequate radiation shielding for astronauts performing the in-vacuum electron beam welding. NASA, in a joint venture with the Russian Space Agency, was scheduled to perform a series of welding in space experiments on board the United States Space Shuttle. This series of experiments was named the International Space Welding Experiment (ISWE). The hardware associated with the ISWE was leased to NASA, by the Paton Welding Institute (PWI) in Ukraine, for ground based welding experiments in preparation for flight. Two ground tests were scheduled, using the ISWE electron beam welding tool, to characterize the radiation exposure to an astronaut during the operation of the ISWE. These radiation exposure tests used Thermoluminescence Dosimeters (TLD's) shielded with material currently used by astronauts during Extra Vehicular Activities (EVA) to measure the radiation dose. The TLD's were exposed to x- ray radiation generated by operation of the ISWE in- vacuum electron beam welding tool. This investigation was the first known application of TLD's to measure absorbed dose from x-rays of energy less than 10 keV. The ISWE hardware was returned to Ukraine before the issue of adequate shielding for the astronauts was completely verified. Therefore alternate experimental and analytical methods were developed to measure and predict the x-ray spectral and intensity distribution generated by ISWE electron beam impact with metal. These x-ray spectra were normalized to an equivalent ISWE exposure then used to calculate the absorbed radiation dose to astronauts. These absorbed dose values were compared to TLD measurements obtained during

  16. Phase-dependent absorption features in X-ray spectra of X-ray Dim Isolated Neutron Stars

    Science.gov (United States)

    Borghese, A.; Rea, N.; Coti Zelati, F.; Turolla, R.; Tiengo, A.; Zane, S.

    2017-12-01

    A detailed phase-resolved spectroscopy of archival XMM–Newton observations of X-ray Dim Isolated Neutron Stars (XDINSs) led to the discovery of narrow and strongly phase-dependent absorption features in two of these sources. The first was discovered in the X-ray spectrum of RX J0720.4-3125, followed by a new possible candidate in RX J1308.6+2127. Both spectral lines have similar properties: they are detected for only ∼ 20% of the rotational cycle and appear to be stable over the timespan covered by the observations. We performed Monte Carlo simulations to test the significance of these phase-variable features and in both cases the outcome has confirmed the detection with a confidence level > 4.6σ. Because of the narrow width and the strong dependence on the pulsar rotational phase, the most likely interpretation for these spectral features is in terms of resonant proton cyclotron absorption scattering in a confined high-B structure close to the stellar surface. Within the framework of this interpretation, our results provide evidence for deviations from a pure dipole magnetic field on small scales for highly magnetized neutron stars and support the proposed scenario of XDINSs being aged magnetars, with a strong non-dipolar crustal B-field component.

  17. X-ray spectra and time variability of active galactic nuclei

    International Nuclear Information System (INIS)

    Mushotzky, R.F.

    1984-02-01

    The X-ray spectra of broad line active galactic nuclei (AGN) of all types (Seyfert I's, NELG's, broadline radio galaxies) are well fit by a power law in the .5 to 100 keV band of man energy slope alpha .68 + or - .15. There is, as yet, no strong evidence for time variability of this slope in a given object. The constraints that this places on simple models of the central energy source are discussed. BL Lac objects have quite different X-ray spectral properties and show pronounced X-ray spectral variability. On time scales longer than 12 hours most radio quiet AGN do not show strong, delta I/I .5, variability. The probability of variability of these AGN seems to be inversely related to their luminosity. However characteristics timescales for variability have not been measured for many objects. This general lack of variability may imply that most AGN are well below the Eddington limit. Radio bright AGN tend to be more variable than radio quiet AGN on long, tau approx 6 month, timescales

  18. Development of a normal incidence multilayer, imaging X-ray microscope

    International Nuclear Information System (INIS)

    Shealy, D.L.; Hoover, R.B.; Walker, A.B.C. Jr.; Barbee, T.W. Jr.

    1989-01-01

    This paper describes the design, analysis, and fabrication of a normal-incidence multilayer 20x Schwarzschild imaging X-ray microscope. The microscope is being fabricated using much of the technology implemented in the Multispectral Solar Telescope Array. Results of diffraction analysis show that better than 400 A spatial resolution in the object plane up to a 1-mm field of view can be achieved with 125 A radiation. Other microscope systems for use in conjunction with X-ray telescopes are analyzed and designed. 18 refs

  19. Possible use of pattern recognition for the analysis of Mars rover X-ray fluorescence spectra

    Science.gov (United States)

    Yin, Lo I; Trombka, Jacob I.; Seltzer, Stephen M.; Johnson, Robert G.; Philpotts, John A.

    1989-01-01

    On the Mars rover sample-return mission, the rover vehicle will collect and select samples from different locations on the Martian surface to be brought back to earth for laboratory studies. It is anticipated that an in situ energy-dispersive X-ray fluorescence (XRF) spectrometer will be on board the rover. On such a mission, sample selection is of higher priority than in situ quantitative chemical anlaysis. With this in mind, a pattern recognition technique is proposed as a simple, direct, and speedy alternative to detailed chemical analysis of the XRF spectra. The validity and efficacy of the pattern recognition technique are demonstrated by the analyses of laboratory XRF spectra obtained from a series of geological samples, in the form both of standardized pressed pellets and as unprepared rocks. It is found that pattern recognition techniques applied to the raw XRF spectra can provide for the same discrimination among samples as a knowledge of their actual chemical composition.

  20. Broadband X-ray spectra of the ultraluminous x-ray source Holmberg IX X-1 observed with NuSTAR, XMM-Newton, and Suzaku

    DEFF Research Database (Denmark)

    Walton, D. J.; Harrison, F. A.; Grefenstette, B. W.

    2014-01-01

    We present results from the coordinated broadband X-ray observations of the extreme ultraluminous X-ray source Holmberg IX X-1 performed by NuSTAR, XMM-Newton, and Suzaku in late 2012. These observations provide the first high-quality spectra of Holmberg IX X-1 above 10 keV to date, extending the X...... exhibits a spectrum consistent with emission from the standard low/hard accretion state seen in Galactic black hole binaries, which would have been expected if Holmberg IX X-1 harbors a truly massive black hole accreting at substantially sub-Eddington accretion rates. The NuSTAR data confirm...... at the highest energies, which may further support this scenario. The available data allow for either of the two thermal components to dominate the spectral evolution, although both scenarios require highly nonstandard behavior for thermal accretion disk emission....

  1. EMISSION LINES BETWEEN 1 AND 2 keV IN COMETARY X-RAY SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Ian; Christian, Damian J. [Department of Physics and Astronomy, California State University, 18111 Nordhoff Street, Northridge, CA 91330 (United States); Bodewits, Dennis [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Dennerl, Konrad [Max-Planck-Institut fuer extraterrestrische Physik, Postfach 1312, D-85741 Garching Germany (Germany); Lisse, Carey M. [Planetary Exploration Group, Space Department, Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Rd, Laurel, MD 20723 (United States); Wolk, Scott J., E-mail: ian.ewing.794@my.csun.edu, E-mail: daman.christian@csun.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2013-01-20

    We present the detection of new cometary X-ray emission lines in the 1.0-2.0 keV range using a sample of comets observed with the Chandra X-Ray Observatory and ACIS spectrometer. We have selected five comets from the Chandra sample with good signal-to-noise spectra. The surveyed comets are C/1999 S4 (LINEAR), C/1999 T1 (McNaught-Hartley), 153P/2002 (Ikeya-Zhang), 2P/2003 (Encke), and C/2008 8P (Tuttle). We modeled the spectra with an extended version of our solar wind charge exchange (SWCX) emission model. Above 1 keV, we find Ikeya-Zhang to have strong emission lines at 1340 and 1850 eV which we identify as being created by SWCX lines of Mg XI and Si XIII, respectively, and weaker emission lines at 1470, 1600, and 1950 eV formed by SWCX of Mg XII, Mg XI, and Si XIV, respectively. The Mg XI and XII and Si XIII and XIV lines are detected at a significant level for the other comets in our sample (LS4, MH, Encke, 8P), and these lines promise additional diagnostics to be included in SWCX models. The silicon lines in the 1700-2000 eV range are detected for all comets, but with the rising background and decreasing cometary emission, we caution that these detections need further confirmation with higher resolution instruments.

  2. X-Ray Spectra from MHD Simulations of Accreting Black Holes

    Science.gov (United States)

    Schnittman, Jeremy D.; Krolik, Julian H.; Noble, Scott C.

    2012-01-01

    We present the results of a new global radiation transport code coupled to a general relativistic magneto-hydrodynamic simulation of an accreting, nonrotating black hole. For the first time, we are able to explain from first principles in a self-consistent way the X-ray spectra observed from stellar-mass black holes, including a thermal peak, Compton reflection hump, power-law tail, and broad iron line. Varying only the mass accretion rate, we are able to reproduce the low/hard, steep power-law, and thermal-dominant states seen in most galactic black hole sources. The temperature in the corona is T(sub e) 10 keV in a boundary layer near the disk and rises smoothly to T(sub e) greater than or approximately 100 keV in low-density regions far above the disk. Even as the disk's reflection edge varies from the horizon out to approximately equal to 6M as the accretion rate decreases, we find that the shape of the Fe Ka line is remarkably constant. This is because photons emitted from the plunging region are strongly beamed into the horizon and never reach the observer. We have also carried out a basic timing analysis of the spectra and find that the fractional variability increases with photon energy and viewer inclination angle, consistent with the coronal hot spot model for X-ray fluctuations.

  3. Electronic structure, charge distribution and X-ray emission spectra of V3Si

    International Nuclear Information System (INIS)

    Anisimov, V.I.; Gubanov, V.A.; Ivanovskii, A.L.; Kurmaev, E.Z.; Weber, J.; Lacroix, R.

    1979-01-01

    Cluster calculations of the electronic structure and charge distribution in V 3 Si have been performed using two different molecular orbital methods: a semiempirical LCAO and the MS Xα model. The results are compared with X-ray emission spectra and band structure calculations. An analysis of the calculated electronic distribution reveals a charge transfer from Si-atoms to V-atoms, the additional charge on a V-atom being 0.6e (LCAO) and 0.4e (MS Xα method). The results are in good agreement with experiment, which indicates that the cluster approach is adequate for the description of charge distributions and spectra characteristics of the A-15 compounds. (author)

  4. The supersoft X-ray source in V5116 Sagittarii. I. The high resolution spectra

    Science.gov (United States)

    Sala, G.; Ness, J. U.; Hernanz, M.; Greiner, J.

    2017-05-01

    Context. Classical nova explosions occur on the surface of an accreting white dwarf in a binary system. After ejection of a fraction of the envelope and when the expanding shell becomes optically thin to X-rays, a bright source of supersoft X-rays arises, powered by residual H burning on the surface of the white dwarf. While the general picture of the nova event is well established, the details and balance of accretion and ejection processes in classical novae are still full of unknowns. The long-term balance of accreted matter is of special interest for massive accreting white dwarfs, which may be promising supernova Ia progenitor candidates. Nova V5116 Sgr 2005b was observed as a bright and variable supersoft X-ray source by XMM-Newton in March 2007, 610 days after outburst. The light curve showed a periodicity consistent with the orbital period. During one third of the orbit the luminosity was a factor of seven brighter than during the other two thirds of the orbital period. Aims: In the present work we aim to disentangle the X-ray spectral components of V5116 Sgr and their variability. Methods: We present the high resolution spectra obtained with XMM-Newton RGS and Chandra LETGS/HRC-S in March and August 2007. Results: The grating spectrum during the periods of high-flux shows a typical hot white dwarf atmosphere dominated by absorption lines of N VI and N VII. During the low-flux periods, the spectrum is dominated by an atmosphere with the same temperature as during the high-flux period, but with several emission features superimposed. Some of the emission lines are well modeled with an optically thin plasma in collisional equilibrium, rich in C and N, which also explains some excess in the spectra of the high-flux period. No velocity shifts are observed in the absorption lines, with an upper limit set by the spectral resolution of 500 km s-1, consistent with the expectation of a non-expanding atmosphere so late in the evolution of the post-nova. Based on

  5. Characterization of ion beam sputtered deposited W/Si multilayers by grazing incidence x-ray diffraction and x-ray reflectivity technique

    Science.gov (United States)

    Dhawan, Rajnish; Rai, Sanjay

    2016-05-01

    W/Si multilayers four samples have been deposited on silicon substrate using ion beam sputtering system. Thickness of tungsten (W) varies from around 10 Å to 40 Å while the silicon (Si) thickness remains constant at around 30 Å in multilayers [W-Si]x4. The samples have been characterized by grazing incidence X-ray diffraction (GIXRD) and X-ray reflectivity technique (XRR). GIXRD study shows the crystalline behaviour of W/Si multilayer by varying W thickness and it is found that above 20 Å the W film transform from amorphous to crystalline phase and X-ray reflectivity data shows that the roughnesses of W increases on increasing the W thicknesses in W/Si multilayers.

  6. Analysis of mesoporous thin films by X-ray reflectivity, optical reflectivity and grazing incidence small angle X-ray scattering

    International Nuclear Information System (INIS)

    Gibaud, A.; Dourdain, S.; Vignaud, G.

    2006-01-01

    It is well-established that X-ray reflectivity (XR) is an invaluable tool to investigate the structure of thin films. Indeed, this technique provides under correct analysis, the electron density profile of thin films in the direction perpendicular to the substrate. For thin films that exhibit lateral ordering at the nanometer scale, grazing incidence small angle X-ray scattering (GISAXS) ideally complements the XR technique to measure the scattering in off-specular directions. As typical examples, XR and GISAXS data of mesoporous silica thin films and porous materials are presented. The analysis of the XR curve allows to determine the porosity of the film. We also show that the combination of X-ray and visible optical reflection provides information about the index of refraction of thin films. Finally we report how capillary condensation of water can be monitored by XR and GISAXS

  7. Generation and analysis of clinically relevant breast imaging x-ray spectra.

    Science.gov (United States)

    Hernandez, Andrew M; Seibert, J Anthony; Nosratieh, Anita; Boone, John M

    2017-06-01

    The purpose of this work was to develop and make available x-ray spectra for some of the most widely used digital mammography (DM), breast tomosynthesis (BT), and breast CT (bCT) systems in North America. The Monte Carlo code MCNP6 was used to simulate minimally filtered (only beryllium) x-ray spectra at 8 tube potentials from 20 to 49 kV for DM/BT, and 9 tube potentials from 35 to 70 kV for bCT. Vendor-specific anode compositions, effective anode angles, focal spot sizes, source-to-detector distances, and beryllium filtration were simulated. For each 0.5 keV energy bin in all simulated spectra, the fluence was interpolated using cubic splines across the range of simulated tube potentials to produce spectra in 1 kV increments from 20 to 49 kV for DM/BT and from 35 to 70 kV for bCT. The HVL of simulated spectra with conventional filtration (at 35 kV for DM/BT and 49 kV for bCT) was used to assess spectral differences resulting from variations in: (a) focal spot size (0.1 and 0.3 mm IEC), (b) solid angle at the detector (i.e., small and large FOV size), and (c) geometrical specifications for vendors that employ the same anode composition. Averaged across all DM/BT vendors, variations in focal spot and FOV size resulted in HVL differences of 2.2% and 0.9%, respectively. Comparing anode compositions separately, the HVL differences for Mo (GE, Siemens) and W (Hologic, Philips, and Siemens) spectra were 0.3% and 0.6%, respectively. Both the commercial Koning and prototype "Doheny" (UC Davis) bCT systems utilize W anodes with a 0.3 mm focal spot. Averaged across both bCT systems, variations in FOV size resulted in a 2.2% difference in HVL. In addition, the Koning spectrum was slightly harder than Doheny with a 4.2% difference in HVL. Therefore to reduce redundancy, a generic DM/BT system and a generic bCT system were used to generate the new spectra reported herein. The spectral models for application to DM/BT were dubbed the Molybdenum, Rhodium, and Tungsten Anode

  8. Lα1 satellites in X-ray emission spectra of higher - Z elements

    International Nuclear Information System (INIS)

    Poonia, S.

    2004-01-01

    Full text: The X-ray satellite spectra arising due to 2p 3/2 -1 3x -1 - 3x -1 3d -1 (x ≡ s, p, d) transition array, in elements with Z 74 to 92, have been calculated. While the energies of various transitions of the array have been determined by using available Hartree-Fock-Slater data on 1s -1 - 2p -1 3x -1 and 2p 3/2 -1 - 3x -1 , 3x' -1 Auger transition energies and their relative intensities have been estimated by considering cross - sections of singly ionized 2x -1 (x ≡ s, p) states and then of subsequent Coster-Kronig and shake off processes. The calculated spectra have been compared with the measured satellite energies in Lα1 spectra. Their intense peaks have been identified as the observed satellite lines. The one to one correspondence between the peaks in calculated spectra and the satellites in measured spectra has been established on the basis of the agreement between the separations in the peak energies and those in the measured satellite energies. It has been established that three satellites observed in the Lα 1 region of the X-ray spectra of various elements and named α', α ix and α x in order of increasing energy are mainly emitted by 2p 3/2 -1 3d -1 - 3d -2 transitions. It is observed that the satellite α' in all these spectra can be assigned to the superposition of 3 F 4 - 3 F 4 transition and that this must be most intense one out of all these satellites, contributing in order of decreasing intensity. The line α ix , has been assigned to mainly the 1 F 3 - 1 G 4 , 1 P 1 - 1 D 2 and 1 F 3 - 1 D 2 transitions. Finally, the satellite α x , reported in the spectra of elements with Z = 74-92, has been associated with the transition 3 D 3 - 3 F 4 . The possible contributions of other transitions of the 2p 3/2 -1 3x -1 - 3x -1 3d -1 (x ≡ s, p, d) array having appreciable intensities, have also been discussed

  9. The formation of amplitude spectra in X-ray pixel detectors made of gallium arsenide.

    Science.gov (United States)

    Ayzenshtat, Gennadiy; Prokopiev, Dmitriy; Baidali, Sergey; Tolbanov, Oleg; Dorzheeva, Larisa

    2017-02-21

    This study aims to analyse energy spectra formation in semiconductor X-ray pixel detectors using a simple experimental method. The calculations were performed for the pixel detectors made of high-resistivity gallium arsenide compensated by chromium GaAs (Cr). A peculiar feature of these detectors is an extremely short lifetime of the holes. When using ordinary detectors with planar electrodes the spectra with high energy resolution could not be observed. In this study, the shape of amplitude spectra of gamma rays were calculated with energy W0 = 60 and 17 keV. The calculations were performed for the pixel detector of GaAs (Cr) with the thickness of d = 500μm and pixel pitch of 50μm. The mobility of electrons and holes were assumed to be μn = 3000 cm2/Vs, μp = 300 cm2/Vs, and the lifetimes were τn = 20 ns and τp = 1 ns, respectively. It was demonstrated that in the pixel detector, where there was practically no collection of holes and the amplitude spectra occurred with the energy resolution of 3.5 keV. The calculations show that energy spectra of the pixel detectors has a high energy resolution at an appropriate polarity applied bias voltage. The calculation results were conformed by the experimental data.

  10. Note: Grazing incidence small and wide angle x-ray scattering combined with imaging ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Koerstgens, V.; Meier, R.; Ruderer, M. A.; Guo, S.; Chiang, H.-Y.; Mueller-Buschbaum, P. [Technische Universitaet Muenchen, Physik-Department, Lehrstuhl fuer Funktionelle Materialien, James-Franck-Str. 1, 85748 Garching (Germany); Perlich, J.; Roth, S. V.; Gehrke, R. [HASYLAB, DESY, Notkestr. 85, 22607, Hamburg (Germany)

    2012-07-15

    The combination of grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) with optical imaging ellipsometry is presented as an upgrade of the available measurement techniques at the wiggler beamline BW4 of the Hamburger Synchrotronstrahlungslabor. The instrument is introduced with the description of the alignment procedure to assure the measurement of imaging ellipsometry and GISAXS/GIWAXS on the same sample spot. To demonstrate the possibilities of the new instrument examples of morphological investigation on films made of poly(3-hexylthiophene) and [6,6]-phenyl-C{sub 61} butyric acid methyl ester as well as textured poly(9,9-dioctylfluorene-alt-benzo-thia-diazole) are shown.

  11. On the origin of cyclotron lines in the spectra of X-ray pulsars

    Directory of Open Access Journals (Sweden)

    Mushtukov A. A.

    2014-01-01

    Full Text Available Cyclotron resonance scattering features are observed in the spectra of some X-ray pulsars and show significant changes in the line energy with the pulsar luminosity. In a case of bright sources, the line centroid energy is anti-correlated with the luminosity. Such a behaviour is often associated with the onset and growth of the accretion column, which is believed to be the origin of the observed emission and the cyclotron lines. However, this scenario inevitably implies large gradient of the magnetic field strength within the line-forming region, and it makes the formation of the observed line-like features problematic. Moreover, the observed variation of the cyclotron line energy is much smaller than could be anticipated for the corresponding luminosity changes. We argue that a more physically realistic situation is that the cyclotron line forms when the radiation emitted by the accretion column is reflected from the neutron star surface. The idea is based on the facts that a substantial part of column luminosity is intercepted by the neutron star surface and the reflected radiation should contain absorption features. The reflection model is developed and applied to explain the observed variations of the cyclotron line energy in a bright X-ray pulsar V 0332+53 over a wide range of luminosities.

  12. Pattern-recognition analysis of low-resolution X-ray fluorescence spectra

    Science.gov (United States)

    Yin, Lo I.; Seltzer, Stephen M.

    1990-12-01

    Using a high-resolution Si(Li) spectrometer to perform X-ray fluorescence (XRF) analysis of various geological, alloy, and paint samples, we have demonstrated that in situations where quantitative information is not the primary concern, a pattern-recognition approach may be used to obtain qualitative results very quickly and efficiently. Specifically, the pattern-recognition technique uses a single parameter, the normalized correlation coefficient, to identify and select samples with similar chemical compositions from their raw XRF spectra. The algorithm can be easily implemented on a personal computer; typically it takes only a few seconds to perform the pairwise comparison of 9 or 10 spectra. We report here the results of our attempt to extend the pattern-recognition technique to the analysis of low-resolution XRF spectra from a proportional counter where the spectral information is considerably poorer than that of the Si(Li) detector. Analyzing the XRF spectra obtained from a set of geological samples both in air and in vacuum we find that even with a proportional counter the pattern-recognition technique can nevertheless satisfactorily identify samples with similar chemical compositions.

  13. The influence of calculated CT X-ray spectra on organ absorbed dose to a human phantom

    International Nuclear Information System (INIS)

    Ferreira, C.C.; Vieira, J.W.; Maia, A.F.

    2009-01-01

    We have evaluated the utilization of five X-ray spectra codes for Monte Carlo (MC) simulations of computed tomography (CT) examinations. Four codes (Xcomp5r, X-raytbc, X-rayb and m and Srs-78) are semi-empiricals and one is based on MC methods (EGSnrc/BEAM Monte Carlo code). The X-ray spectra calculated by the semi-empirical codes were compared with the X-ray spectrum calculated by the EGSnrc/BEAM MC code. The absorbed doses to each organ or tissue were also compared. The calculated doses, and its respective organs, for which occurs the greatest disagreement, as well as the calculated doses for the testes and red bone marrow (two important organs used for calculating effective dose) were presented. The results obtained in this work are in good agreement with those obtained by Ay [M.R. Ay, S. Sarkar, M. Shahriari, D. Sardari, H. Zaidi, Assessment of different computational models for generation of X-ray spectra in diagnostic radiology and mammography, Med. Phys. 32 (2005) 1660], mainly for the bremsstrahlung distribution. Also, it was noted that the total characteristic X-rays produced by the EGSnrc/BEAM MC code increases with the increase of voltage more intensely than with the Xcomp5r, X-raytbc and Srs-78 codes. Comparison between the absorbed dose to each organ or tissue showed that, for X-ray spectra with additional filtration, the code based on Tucker et al. is in agreement with EGSnrc/BEAM MC code. But, for X-ray spectra without additional filtration the code based on Tucker et al. model presented the strong disagreement with EGSnrc/BEAM MC code.

  14. The influence of calculated CT X-ray spectra on organ absorbed dose to a human phantom

    Science.gov (United States)

    Ferreira, C. C.; Vieira, J. W.; Maia, A. F.

    2009-10-01

    We have evaluated the utilization of five X-ray spectra codes for Monte Carlo (MC) simulations of computed tomography (CT) examinations. Four codes (Xcomp5r, X-raytbc, X-rayb&m and Srs-78) are semi-empiricals and one is based on MC methods (EGSnrc/BEAM Monte Carlo code). The X-ray spectra calculated by the semi-empirical codes were compared with the X-ray spectrum calculated by the EGSnrc/BEAM MC code. The absorbed doses to each organ or tissue were also compared. The calculated doses, and its respective organs, for which occurs the greatest disagreement, as well as the calculated doses for the testes and red bone marrow (two important organs used for calculating effective dose) were presented. The results obtained in this work are in good agreement with those obtained by Ay [M.R. Ay, S. Sarkar, M. Shahriari, D. Sardari, H. Zaidi, Assessment of different computational models for generation of X-ray spectra in diagnostic radiology and mammography, Med. Phys. 32 (2005) 1660], mainly for the bremsstrahlung distribution. Also, it was noted that the total characteristic X-rays produced by the EGSnrc/BEAM MC code increases with the increase of voltage more intensely than with the Xcomp5r, X-raytbc and Srs-78 codes. Comparison between the absorbed dose to each organ or tissue showed that, for X-ray spectra with additional filtration, the code based on Tucker et al. is in agreement with EGSnrc/BEAM MC code. But, for X-ray spectra without additional filtration the code based on Tucker et al. model presented the strong disagreement with EGSnrc/BEAM MC code.

  15. X-ray imaging with grazing-incidence microscopes developed for the LIL program

    International Nuclear Information System (INIS)

    Rosch, R.; Boutin, J. Y.; Le Breton, J. P.; Gontier, D.; Jadaud, J. P.; Reverdin, C.; Soullie, G.; Lidove, G.; Maroni, R.

    2007-01-01

    This article describes x-ray imaging with grazing-incidence microscopes, developed for the experimental program carried out on the Ligne d'Integration Laser (LIL) facility [J. P. Le Breton et al., Inertial Fusion Sciences and Applications 2001 (Elsevier, Paris, 2002), pp. 856-862] (24 kJ, UV--0.35 nm). The design includes a large target-to-microscope (400-700 mm) distance required by the x-ray ablation issues anticipated on the Laser MegaJoule facility [P. A. Holstein et al., Laser Part. Beams 17, 403 (1999)] (1.8 MJ) which is under construction. Two eight-image Kirkpatrick-Baez microscopes [P. Kirkpatrick and A. V. Baez J. Opt. Soc. Am. 38, 766 (1948)] with different spectral wavelength ranges and with a 400 mm source-to-mirror distance image the target on a custom-built framing camera (time resolution of ∼80 ps). The soft x-ray version microscope is sensitive below 1 keV and its spatial resolution is better than 30 μm over a 2-mm-diam region. The hard x-ray version microscope has a 10 μm resolution over an 800-μm-diam region and is sensitive in the 1-5 keV energy range. Two other x-ray microscopes based on an association of toroidal/spherical surfaces (T/S microscopes) produce an image on a streak camera with a spatial resolution better than 30 μm over a 3 mm field of view in the direction of the camera slit. Both microscopes have been designed to have, respectively, a maximum sensitivity in the 0.1-1 and 1-5 keV energy range. We present the original design of these four microscopes and their test on a dc x-ray tube in the laboratory. The diagnostics were successfully used on LIL first experiments early in 2005. Results of soft x-ray imaging of a radiative jet during conical shaped laser interaction are shown

  16. Partially coherent X-ray wavefront propagation simulations including grazing-incidence focusing optics.

    Science.gov (United States)

    Canestrari, Niccolo; Chubar, Oleg; Reininger, Ruben

    2014-09-01

    X-ray beamlines in modern synchrotron radiation sources make extensive use of grazing-incidence reflective optics, in particular Kirkpatrick-Baez elliptical mirror systems. These systems can focus the incoming X-rays down to nanometer-scale spot sizes while maintaining relatively large acceptance apertures and high flux in the focused radiation spots. In low-emittance storage rings and in free-electron lasers such systems are used with partially or even nearly fully coherent X-ray beams and often target diffraction-limited resolution. Therefore, their accurate simulation and modeling has to be performed within the framework of wave optics. Here the implementation and benchmarking of a wave-optics method for the simulation of grazing-incidence mirrors based on the local stationary-phase approximation or, in other words, the local propagation of the radiation electric field along geometrical rays, is described. The proposed method is CPU-efficient and fully compatible with the numerical methods of Fourier optics. It has been implemented in the Synchrotron Radiation Workshop (SRW) computer code and extensively tested against the geometrical ray-tracing code SHADOW. The test simulations have been performed for cases without and with diffraction at mirror apertures, including cases where the grazing-incidence mirrors can be hardly approximated by ideal lenses. Good agreement between the SRW and SHADOW simulation results is observed in the cases without diffraction. The differences between the simulation results obtained by the two codes in diffraction-dominated cases for illumination with fully or partially coherent radiation are analyzed and interpreted. The application of the new method for the simulation of wavefront propagation through a high-resolution X-ray microspectroscopy beamline at the National Synchrotron Light Source II (Brookhaven National Laboratory, USA) is demonstrated.

  17. X-Ray spectra background fitting by projection onto convex sets

    CERN Document Server

    Brunetti, A

    2000-01-01

    An X-ray spectrum is constituted by a set of peaks superimposed to a background (continuum). If a quantitative estimate of the peak areas is required, then the background must be separated from the spectrum. Several algorithms have been proposed in the literature. These algorithms will generally work well when the amplitudes of the peaks are much more intense than the background. We propose a novel method, based on projections onto convex sets. The algorithm have been tested over a large set of spectra, real and simulated. Some of the results obtained in these tests are reported here and are compared to a widely used continuum estimation method, i.e. the orthogonal polynomial decomposition.

  18. Total reflection X-ray fluorescence polymer spectra: classification by taxonomy statistic tools.

    Science.gov (United States)

    Vázquez, Cristina; Boeykens, Susana; Bonadeo, H

    2002-07-19

    The aim of this work is to explore the use of chemometric tools for the classification of synthetic and natural polymers with a mean molecular weight greater than 10(6). Total Reflection X-Ray Fluorescence (TXRF) spectra were obtained and analyzed in order to retrieve matrix information and to illustrate the calibration procedure. The intensities of the coherent and incoherent scattered peaks were specially selected for this purpose. The polymers studied were aqueous solutions of scleroglucan, polyacrilamide, polyoxyethylene oxide, glucomannan, 2,3,6-tri-o-ethylamylose and xhantan, in concentrations upto 1% (m/m). matlab software was used for numerical calculations. Using a combination of principal component analysis and cluster analysis, the differences in composition of various analyzed polymers can be visualized.

  19. Studies on polymer thin film structure by X-ray and neutron reflectivity and grazing incidence small angle scattering

    International Nuclear Information System (INIS)

    Ogawa, Hiroki; Kanaya, Toshiji

    2011-01-01

    We have reviewed structure studies of polymer thin films using synchrotron radiation X-ray and neutron reflectivity as well as recently developed grazing incidence small-angle X-ray and neutron scattering, including studies on polymer thin films with embedded ordered nanometer cells, distribution of glass transition temperature Tg in thin polystyrene films, and dewetting process of polymer blend thin films. (author)

  20. First combined total reflection X-ray fluorescence and grazing incidence X-ray absorption spectroscopy characterization of aeolian dust archived in Antarctica and Alpine deep ice cores

    Energy Technology Data Exchange (ETDEWEB)

    Cibin, G. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxon OX110DE (United Kingdom); IMONT/EIM, Ente Italiano della Montagna, P.za dei Caprettari 70, 00176 Roma (Italy); Universita' degli Studi di Roma Tre, Dipartimento di Scienze Geologiche, L.go S. Leonardo Murialdo 1, 00146 Roma (Italy)], E-mail: giannantonio.cibin@diamond.ac.uk; Marcelli, A. [INFN - Laboratori Nazionali di Frascati, P.O. Box 13, 00044 Frascati (Roma) (Italy); Maggi, V. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Sala, M. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze della Terra ' A. Desio' , Sez. Mineralogia, Via Mangiagalli 34, 20133 Milano (Italy); Marino, F.; Delmonte, B. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Albani, S. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Universita degli Studi di Siena, Dottorato in Scienze Polari, via Laterina 8, 53100 Siena (Italy); Pignotti, S. [IMONT/EIM, Ente Italiano della Montagna, P.za dei Caprettari 70, 00176 Roma (Italy)

    2008-12-15

    Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1-10 {mu}g range.

  1. Anatomy of the AGN in NGC 5548. IX. Photoionized emission features in the soft X-ray spectra

    Science.gov (United States)

    Mao, Junjie; Kaastra, J. S.; Mehdipour, M.; Gu, Liyi; Costantini, E.; Kriss, G. A.; Bianchi, S.; Branduardi-Raymont, G.; Behar, E.; Di Gesu, L.; Ponti, G.; Petrucci, P.-O.; Ebrero, J.

    2018-04-01

    The X-ray narrow emission line region (NELR) of the archetypal Seyfert 1 galaxy NGC 5548 has been interpreted as a single-phase photoionized plasma that is absorbed by some of the warm absorber components. This scenario requires those overlaying warm absorber components to have larger distance (to the central engine) than the X-ray NELR, which is not fully consistent with the distance estimates found in the literature. Therefore, we reanalyze the high-resolution spectra obtained in 2013-2014 with the Reflection Grating Spectrometer (RGS) aboard XMM-Newton to provide an alternative interpretation of the X-ray narrow emission features. We find that the X-ray narrow emission features in NGC 5548 can be described by a two-phase photoionized plasma with different ionization parameters (logξ = 1.3 and 0.1) and kinematics (vout = -50 and -400 km s-1), and no further absorption by the warm absorber components. The X-ray and optical NELR might be the same multi-phase photoionized plasma. Both X-ray and optical NELR have comparable distances, asymmetric line profiles, and the underlying photoionized plasma is turbulent and compact in size. The X-ray NELR is not the counterpart of the UV/X-ray absorber outside the line of sight because their distances and kinematics are not consistent. In addition, X-ray broad emission features that we find in the spectrum can be accounted for by a third photoionized emission component. The RGS spectrum obtained in 2016 is analyzed as well, where the luminosity of most prominent emission lines (the O VII forbidden line and O VIII Lyα line) are the same (at a 1σ confidence level) as in 2013-2014.

  2. Optimization of Grazing Incidence Optics for Wide-Field X-Ray Survey Imaging

    Science.gov (United States)

    Roming, P. W. A.; Burrows, D. N.; Garmire, G. P.; Roush, W. B.

    1999-12-01

    Optimization of wide-field X-ray optics could greatly enhance X-ray surveys. Discussions of optimizing wide-field X-ray optics, with field-of-views less-than 1.1 degree-squared, have been made previously in the literature. However, very little has been published about the optimizing of wide-field X-ray optics with larger fields-of-view. We have been working on the design of a wide-field (3.1 degree-squared field-of-view), short focal length (190.5 cm), grazing incidence mirror shell set, with a desired rms image spot size of 15 arcsec. The baseline design incorporates Wolter I type mirror shells with polynomial perturbations applied to the grazing incidence surface. By optimizing the polynomial, the rms image spot size can be minimized for a large range of grazing angles. The overall minimization technique is to efficiently optimize the polynomial coefficients that directly influence the angular resolution, without stepping through the entire multidimensional coefficient space. The multidimensional minimization techniques that have been investigated include: the downhill simplex method; the coupling of genetic algorithms with full and fractional, including Plackett-Burman, factorial designs; and the coupling of genetic algorithms with Box-Behnken and central composite response surface designs. We have also examined the use of neural networks, coupled with genetic algorithms, as a method of multidimensional minimization. Investigations of backpropagation, probabilistic (PNN), general regression (GRNN), and group method of data handling (GMDH) neural networks have been made. We report our findings to date. This research is funded by NASA grant #NAG5-5093.

  3. MEASUREMENT OF THE HIGH ENERGY COMPONENT OF THE X-RAY SPECTRA INTHE VENUS ECR ION SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Benitez, Janilee Y.; Lyneis, Claude M.; Todd,Damon S.; Ropponen,Tommi; Ropponen,Janne; Koivisto, Hannu; Gammino, Santo

    2007-11-15

    High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for Nuclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental set-up to measure bremsstrahlung spectra from ECR ion sources is somewhat different than for the traditional nuclear physics measurements these detectors are generally used for. In particular the collimation and background shielding can be problematic. In this paper we will discuss the experimental set-up for such a measurement, the energy calibration and background reduction, the correction for detector efficiency, the shielding of the detector and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates in dependence of various ion source parameters such as confinement fields, minimum B-field, rf power and heating frequency.

  4. Parallel of semi-empirical results simulated by MCNP of X-ray spectra with a semiconductor

    International Nuclear Information System (INIS)

    Santos, L.R.; Vivolo, V.; Potiens, M.P.A.; Navarro, M.V.T.; Santos, W.S.

    2016-01-01

    The aim of this study was to use the MCNPX radiation transport code to simulate X-ray spectra generated by a constant voltage system in a CdTe semiconductor detector. As part of the validation process, we obtained a series of experimental spectra. Comparatively, in all cases there is a good correlation between the two spectra. There were no statistically significant differences between the experimental results with the simulated. (author)

  5. Indirect measurements of X-ray spectra; Mediciones indirectas de espectros de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mainardi, R.T. [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, X5000HUA Cordoba (Argentina)

    2006-07-01

    To the effects of measuring the spectral distribution of the radiation emitted by the x-ray tubes and electron accelerators, numerous procedures that are grouped in two big categories exist at the present time: direct and indirect methods. The first ones use high resolution detectors that should be positioned, together with the appropriate collimator, in the direction of the x ray beam. The user should be an expert in the use and correction of the obtained data by the different effects that affect the detector operation such as efficiency and resolution in terms of the energy of the detected radiation. The indirect procedures, although its are more simple to use, its also require a considerable space along the beam to position the ionization chamber and the necessary absorbents to construct by this way the denominated attenuation curve. We will analyze the operation principle of the indirect methods and a new proposal in which such important novelties are introduced as the beam dispersion to avoid to measure along the main beam and that of determination of the attenuation curve in simultaneous form. By this way, with a single shot of the tube, the attenuation curve is measured, being necessary at most a shot of additional calibration to know the relative response of the detectors used in the experimental array. The physical processes involved in the obtaining of an attenuation curve are very well well-known and this it finishes it can be theoretically calculated if the analytic form of the spectrum is supposed well-known. Finally, we will see a spectra reconstruction example with the Kramers parametric form and comparisons with numeric simulations carried out with broadly validated programs as well as the possibility of the use of solid state dosemeters in the obtention of the attenuation curve. (Author)

  6. Excitation and propagation of X-ray fluorescence through thin devices with hollowed ordered structures: comparison of experimental and theoretical spectra.

    Science.gov (United States)

    Mazuritskiy, M I; Dabagov, S B; Marcelli, A; Lerer, A M; Dziedzic-Kocurek, K

    2016-01-01

    The lack of models describing the propagation of X-rays in waveguides and the interference mechanism between incident and reflected radiation waves hamper the understanding and the control of wave propagation phenomena occurring in many real systems. Here, experimental spectra collected at the exit of microchannel plates (MCPs) under the total X-ray reflection condition are presented. The results are discussed in the framework of a theoretical model in which the wave propagation is enhanced by the presence of a transition layer at the surface. The angular distributions of the propagating radiation at the exit of these MCPs with microchannels of ∼3 µm diameter will also be presented and discussed. These spectra show contributions associated with the reflection of the primary monochromatic beam and with the fluorescence radiation originating from the excitation of atoms composing the surface of the microchannel. The soft X-ray fluorescence spectra collected at the exit of microcapillaries were analyzed in the framework of a wave approximation while diffraction contributions observed at the exit of these hollow X-ray waveguides have been calculated using the Fraunhofer diffraction model for waves in the far-field domain. Data collected at the Si L-edge show that in glassy MCPs the fluorescence radiation can be detected only when the energy of the primary monochromatic radiation is above the absorption edge for grazing angles higher than half of the critical angle of the total reflection phenomenon. Experimental data and simulations of the propagating radiation represent a clear experimental confirmation of the channeling phenomenon of the excited fluorescence radiation inside a medium and point out that a high transmission can be obtained in waveguide optics for parameters relevant to X-ray imaging.

  7. Study of the grazing-incidence X-ray scattering of strongly disturbed fractal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Roshchin, B. S., E-mail: ross@crys.ras.ru; Chukhovsky, F. N.; Pavlyuk, M. D.; Opolchentsev, A. M.; Asadchikov, V. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Research Centre “Crystallography and Photonics” (Russian Federation)

    2017-03-15

    The applicability of different approaches to the description of hard X-ray scattering from rough surfaces is generally limited by a maximum surface roughness height of no more than 1 nm. Meanwhile, this value is several times larger for the surfaces of different materials subjected to treatment, especially in the initial treatment stages. To control the roughness parameters in all stages of surface treatment, a new approach has been developed, which is based on a series expansion of wavefield over the plane eigenstate-function waves describing the small-angle scattering of incident X-rays in terms of plane q-waves propagating through the interface between two media with a random function of relief heights. To determine the amplitudes of reflected and transmitted plane q-waves, a system of two linked integral equations was derived. The solutions to these equations correspond (in zero order) to the well-known Fresnel expressions for a smooth plane interface. Based on these solutions, a statistical fractal model of an isotropic rough interface is built in terms of root-mean-square roughness σ, two-point correlation length l, and fractal surface index h. The model is used to interpret X-ray scattering data for polished surfaces of single-crystal cadmium telluride samples.

  8. Time-Dependent Density Functional Calculations of Ligand K-Edge X-Ray Absorption Spectra

    Energy Technology Data Exchange (ETDEWEB)

    DeBeer George, S.; /SLAC, SSRL; Petrenko, T.; Neese, F.

    2007-07-10

    X-ray absorption spectra (XAS) at the Cl and S K edge and Mo L edge have been calculated at the TDDFT level for a series of dioxomolybdenum complexes LMoO{sub 2}X (L = hydrotris(3,5-dimethyl-1-pyrazolyl)borate, X = Cl, SCH{sub 2}Ph, OPh), which play an important role in modeling the catalytic cycle of the sulfite oxidase enzyme. Also, the XAS spectra of model molecules of the Mo complexes have been simulated and interpreted in terms of the Mo 4d orbital splitting, in order to find possible correlations with the spectral pattern of the complexes. Comparison with the available experimental data allows us to assess the performances of the present computational scheme to describe the core excitations in large bioinorganic systems. The theoretical interpretation of the spectral features of both the metal and ligand core excitations in terms of the oscillator strength distribution provides important insight into the covalency of the metal-ligand bond.

  9. Analysis of fine structure of X-ray spectra from laser-irradiated gold dot

    International Nuclear Information System (INIS)

    Yang Guohong; Zhang Jiyan; Zhang Baohan; Zhou Yuqing; Li Jun

    2000-01-01

    The X-ray emission spectra from highly stripped plasma of gold has been observed by focusing a Nd-glass frequency tripled laser beam onto the surface of the gold dot at the XINGGUANG II laser facilities. The spectra of gold ions in the range of 0.0003 nm-0.0004 nm was recorded using the plate PET (2d = 0.8742 nm) crystal spectrometer. The code of average energy of relativistic sub-arrays was built on the basis of the code MCDF (Multi-Configuration-Dirac-Fock). Using the spin-orbit-split-arrays (SOSA) formalism, mean wavelengths and full widths at half height of isolated peaks of sub-arrays of lower charged gold ions, isoelectronic with Cu, Zn, Ga and Ge, was calculated. Twenty-six lines are interpreted, they pertain mainly to transitions of 3d-nf (n = 5,6,7) of gold ions from Ni-like to As-like. These results of experiment and calculation have important application in plasma diagnostics and examination of high Z elemental atomic structure calculation

  10. Simulation of pulse height analysis soft X-ray spectra expected from W7-X

    Science.gov (United States)

    Jabłoński, S.; Czarnecka, A.; Kubkowska, M.; Ryć, L.; Weller, A.; Biedermann, C.; König, R.; W7-X Team

    2015-10-01

    A computer code named RayX has been developed for checking the performance of a spectroscopy system and optimizing individual parts, like detectors and filters for the pulse height analysis (PHA) diagnostic system designed for the stellarator W7-X. Using the code, the intensity and shape of the X-ray spectra are simulated for different plasma scenarios characterized by varying the temperature and density profiles as well as the electron cyclotron resonance heating (ECRH) power over a wide range. In the simulations of the recorded spectra, the influence of geometrical configuration changes of the diagnostic system (pinhole size, detector size, location of each diagnostic component), of the timing of data collection, as well as of the type and thickness of filters are being investigated. The atomic processes of free-free (bremsstrahlung), free-bound (recombination radiation), and bound-bound emission (line radiation) are considered. For the impurities fractional abundancies of 3% carbon (C), 0.5% oxygen (O) and 0.002% iron (Fe) are taken into account. Information about the number of photons which reach the detector and the current generated inside the detector is given. It is shown that the distance between pinhole and detector has a larger impact on the registered spectra (intensity and total number of photons) than the distance between plasma and pinhole. Based on the results of the simulations, the expected optimal positions of the individual components (pinholes, detectors) were defined for the PHA W7-X diagnostic system. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  11. Determination of semi-reducing layer and applied stress through spectra emitted by an X-ray tube

    International Nuclear Information System (INIS)

    Santos, Josilene C.; Gonzalez, Alejandro H.L.; Terini, Ricardo A.; Costa, Paulo R.

    2016-01-01

    This work describes a method for assessment of half value layer (HVL) and peak tube voltage (kVp) by means of experimental x-ray spectra measured using a CdTe detector. The work also evaluated spectrometry parameters such as dead time and count rate, and x-ray tube characteristics that can affect the assessment of these quantities. Two sets of x-ray spectra were measured: A) using Cu filters with different thicknesses and fixed tube current, and B) keeping a fixed Cu filtration and different tube current and, so, ranging the count rates. The spectrometer was energy calibrated using standard radioactive sources. kVp value was estimated by means of experimental measured x-ray spectra, using linear regression in order to search the end point of each spectrum. HVL was estimated after the correction of the measured spectra, using an analytical method implemented using Matlab® software. For comparison, HVL was also determined using a 30 cm 3 ion chamber and high purity Al filters. (author)

  12. CALCULATION OF MAGNETIC-X-RAY DICHROISM IN 4D AND 5D ABSORPTION-SPECTRA OF ACTINIDES

    NARCIS (Netherlands)

    OGASAWARA, H; KOTANI, A; THOLE, BT

    1991-01-01

    We present atomic calculations of the magnetic dichroism in 4d and 5d x-ray-absorption (XAS) spectra of trivalent actinide ions. The calculations are carried out for both linearly and circularly polarized light at zero temperature. Large magnetic dichroism is predicted for 5d XAS with

  13. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography

    Directory of Open Access Journals (Sweden)

    Lucas Paixão

    2015-12-01

    Full Text Available Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

  14. Monte Carlo derivation of filtered tungsten anode X-ray spectra for dose computation in digital mammography*

    Science.gov (United States)

    Paixão, Lucas; Oliveira, Bruno Beraldo; Viloria, Carolina; de Oliveira, Marcio Alves; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro

    2015-01-01

    Objective Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography. PMID:26811553

  15. Ion trap measurement of U64+ x-ray transition spectra

    International Nuclear Information System (INIS)

    Del Grande, N.K.; Beiersdorfer, P.; Henderson, J.R.; Osterheld, A.L.; Scofield, J.H.; Swenson, J.K.

    1990-09-01

    Highly-charged uranium ions with a dominant nickel-like component (U 64+ ) were produced using the Electron Beam Ion Trap (EBIT) with an electron bombardment energy of 7.4 keV. A comparison of the measured n=4 to n=3 x-ray transition spectra with calculations for U 64+ gave excellent qualitative agreement. The low-energy region of the 4-3 spectrum for the Ni-like ions was characterized by a strong electric quadrupole 4s-3d transition, about as large as the leading dipole 4f-3d transition, which tagged the abundance of U 64+ ions. High resolution spectroscopy was used to measure 4f-3d transition energies for ten charge states: U 60+ -U 69+ excited by 6.4-8.9 keV electrons. The ionization balance for 8.9 keV electron excitation was mostly from five charge states: U 64+ -U 68+ in qualitative agreement with a separate analysis of extracted ions. 16 refs., 4 figs., 3 tabs

  16. Simulation of X-ray absorption spectra with orthogonality constrained density functional theory.

    Science.gov (United States)

    Derricotte, Wallace D; Evangelista, Francesco A

    2015-06-14

    Orthogonality constrained density functional theory (OCDFT) [F. A. Evangelista, P. Shushkov and J. C. Tully, J. Phys. Chem. A, 2013, 117, 7378] is a variational time-independent approach for the computation of electronic excited states. In this work we extend OCDFT to compute core-excited states and generalize the original formalism to determine multiple excited states. Benchmark computations on a set of 13 small molecules and 40 excited states show that unshifted OCDFT/B3LYP excitation energies have a mean absolute error of 1.0 eV. Contrary to time-dependent DFT, OCDFT excitation energies for first- and second-row elements are computed with near-uniform accuracy. OCDFT core excitation energies are insensitive to the choice of the functional and the amount of Hartree-Fock exchange. We show that OCDFT is a powerful tool for the assignment of X-ray absorption spectra of large molecules by simulating the gas-phase near-edge spectrum of adenine and thymine.

  17. Madelung's potentials structure of X-ray emission spectra, and reactivity of alkali metal metavanadates

    Energy Technology Data Exchange (ETDEWEB)

    Kirsanov, V.V.; Fotiev, A.A.; Tskhaj, V.A.; Cherkashenko, V.M. (AN SSSR, Sverdlovsk. Inst. Khimii)

    1983-07-01

    Madelung constants of ionic sublattices, describing the dependence of Madelung potentials on ionic charges in crystallographically non-equivalent V, O and M positions, were calculated for metavanadates MVO/sub 3/ (M=Li, Na, K, Rb, Cs). Semiempirical interpretation of the fine structure and shifts of intensity maximums of X-ray VKsub(..beta..''..beta..sup(5))- and VLsub(..cap alpha..)-emission spectra and X-ray spectral assessment of the degree of chemical bond ionicity in metavanadate oxy-vanadium sublattice are given. The reactivity of these compounds during their interaction with vanadium pentoxide and the activity of different ions in this process were considered.

  18. MATLAB programs for smoothing X-ray spectra; Programy w jezyku MATLAB do wygladzania widm promieniowania X

    Energy Technology Data Exchange (ETDEWEB)

    Antoniak, W.

    1997-12-31

    Two MATLAB 4.0 programs for smoothing X-ray spectra: wekskl.m - using polynomial regression splines and wekfft.m - using the fast Fourier transform are presented. The wekskl.m accomplishes smoothing for optimal distances between the knots, whereas the wekff.m uses an optimal spectral window width. The smoothed spectra are available in the form of vectors and are presented in a graphical form as well. (author). 9 refs, 12 figs.

  19. Nanometer-scale local probing of X-ray absorption spectra of Co/Pt multilayer film

    Science.gov (United States)

    Quach, Duy-Truong; Pham, Duc-Thang; Handoko, Djati; Shim, Je-Ho; Eon Kim, Dong; Lee, Kyung-Min; Jeong, Jong-Ryul; Kim, Namdong; Shin, Hyun-Joon; Kim, Dong-Hyun

    2018-03-01

    We report our local X-ray absorption spectra (XAS) measurement mapping for a Co/Pt multilayer using scanning transmission microscopy with 25-nm spatial resolution and 0.1-eV spectral resolution. We have systematically analyzed the two-dimensional XAS intensity variation over the corresponding magnetic domain patterns, revealing a XAS profile across the magnetic domain wall as well as the simultaneous high-throughput measurement of local XAS spectra.

  20. Ab Initio Calculations of X-ray Spectra : Atomic Multiplet and Molecular Orbital Effects in a Multiconfigurational SCF Approach to the L-Edge Spectra of Transition Metal Complexes

    NARCIS (Netherlands)

    Josefsson, Ida; Kunnus, Kristjan; Schreck, Simon; Foehlisch, Alexander; de Groot, Frank; Wernet, Philippe; Odelius, Michael

    2012-01-01

    A new ab initio approach to the calculation of X-ray spectra is demonstrated. It combines a high-level quantum chemical description of the chemical interactions and local atomic multiplet effects. We show here calculated L-edge X-ray absorption (XA) and resonant inelastic X-ray scattering spectra

  1. ROSAT Energy Spectra of Low-Mass X-Ray Binaries

    Science.gov (United States)

    Schulz, N. S.

    1999-01-01

    The 0.1-2.4 keV bandpass of the ROSAT Position Sensitive Proportional Counter (PSPC) offers an opportunity to study the very soft X-ray continuum of bright low-mass X-ray binaries (LMXBs). In 46 pointed observations, 23 LMXBs were observed with count rates between 0.4 and 165.4 counts s-1. The survey identified a total of 29 different luminosity levels, which are compared with observations and identified spectral states from other missions. The atoll source 4U 1705-44 was observed near Eddington luminosities in an unusually high intensity state. Spectral analysis provided a measure of the interstellar column density for all 49 observations. The sensitivity of spectral fits depends strongly on column density. Fits to highly absorbed spectra are merely insensitive toward any particular spectral model. Sources with column densities well below 1022 cm-2 are best fitted by power laws, while the blackbody model gives clearly worse fits to the data. Most single-component fits from sources with low column densities, however, are not acceptable at all. The inclusion of a blackbody component in eight sources can improve the fits significantly. The obtained emission radii of less than 5 km suggest emission from the neutron star surface. In 10 sources acceptable fits can only be achieved by including soft-line components. With a spectral resolution of the PSPC of 320-450 eV, between 0.6 and 1.2 keV unresolved broad-line features were detected around 0.65, 0.85, and 1.0 keV. The line fluxes range within 10-11 and 10-12 ergs cm-2 s-1, with equivalent widths between 24 and 210 eV. In LMC X-2, 2S 0918-549, and 4U 1254-690, line emission is indicated for the first time. The soft emission observed in 4U 0614+091 compares with recent ASCA results, with a new feature indicated at 1.31 keV. The deduced line fluxes in 4U 1820-30 and Cyg X-2 showed variability of a factor of 2 within timescales of 1-2 days. Average fluxes of line components in 4U 1820-30 varied by the same factor over a

  2. Development of glancing-incidence and glancing-take-off X-ray fluorescence apparatus for surface and thin-film analyses

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Wagatsuma, Kazuaki; Yamada, Takashi; Utaka, Tadashi

    1997-01-01

    We have studied X-ray fluorescence analysis under glancing incidence and glancing take-off conditions. Recently, we have developed a third apparatus for detecting glancing-incidence and take-off X-ray fluorescence, which makes it possible to measure the incident-angle dependence, the take-off-angle dependence. X-ray reflectivity, and X-ray diffraction. Primarily, we have measured the take-off angular dependence of X-ray fluorescence using this apparatus. Glancing take-off X-ray fluorescence has some advantages in comparison with glancing-incidence X-ray fluorescence. The surface density and the absolute angles were determined by analysing the take-off angle dependence of the fluorescent X-rays emitted from identical atoms with the aid of the reciprocity theorem. (Author)

  3. Extended analysis of satellite structures in particle induced X-ray emission spectra using molecular orbital calculations

    Science.gov (United States)

    Uda, U.

    Methods for estimating intensity distributions of X-ray satellite spectra induced by accelerated ions with energies of a few McVlamu are reviewed, where the orbitals responsible for X-ray emission are written in the molecular frame, not in the atomic frame. The ionization cross section is written here in the frame of the direct Coulomb interaction and the shake process. The following two factors are taken into account: (1) changes in the number of orbital electrons due to molecular orbital formation and (2) deviation of the number of electric charges on the projectile ion from the nuclear charge Z. Here the semiclassical approximation (SCA) has been used to calculate the Coulomb interaction between the projectile ion and the orbital electrons. In order to estimate the intensity of X-rays emitted from multiply ionized states changes in the fluorescence yield from the yield of isolated atoms caused by resonant orbital rearrangement (ROR), were also taken into account. Furthermore the energy loss of the projectile ions and absorption of emitted X-rays in the material were taken into account. The agreement between the calculated and the observed X-ray satellite intensities is satisfactory when we use all the correction terms mentioned above.

  4. Survey on th incidence of homeless pulmonary tuberculosis infection rate through chest x-ray examination

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Young; Shin, Sung Rae [Dept. of Nursing, Sahmyook University, Seoul (Korea, Republic of); Ryu, Young Hwan [Dept. of Radiology, Seoul Medical Center, Seoul (Korea, Republic of); Lim, Hwan Yeal [Dept. of Medical Business Administration, U1 University, Yeongdong (Korea, Republic of)

    2017-02-15

    This study, Seoul City shelter, you are trying to seek medical cooperation and cure rate increase proposal Yu fndings’s current situation and tuberculosis of homeless tuberculosis. Inspector, and has a total 591 people is targeted to implement an interview after acquiring utilization agreement in studies conducted chest X-ray photography. Of the interview questions, three or more protons, it is determined that the TB symptomatic conducted sputum examination, chest X-ray examination confrms the physician radiology, when sputum examination primarily chromatic fndings the double implemented and conducted by requesting the ship inspection also said inspection sputum acid-fast bacteria if it is true one, respectively. confrmed case result of checking whether there is a difference due to risk factors (Jb) at the chi square black, it was found that there is no statistically significant difference at 95% confidence level. (χ{sup 2}=0.276, p>0.05), suspected case (Ac, Ae) results of examining whether there is a difference due to risk factors in chi square black, that there is a statistically significant difference at 99% confidence level is I found (χ{sup 2}=9.414, p<0.01). The nature of the homeless tuberculosis screening and directed to the distance homeless specifc location are likely to evaluate the actual incidence low and aggressive or management needs, the rationale is allowed insufficient reality is. Through this research, future, for tuberculosis high risk tuberculosis patient, such as homeless to expand the tuberculosis screening of infectious tuberculosis patients in private medical institutions, and one-stop service that chest X-ray examination and sputum examination is carried out at the same time introduced immediately to prevent the inspection and examination, cure, and should establish a foundation that can be up to post administration.

  5. Survey on th incidence of homeless pulmonary tuberculosis infection rate through chest x-ray examination

    International Nuclear Information System (INIS)

    Kim, Mi Young; Shin, Sung Rae; Ryu, Young Hwan; Lim, Hwan Yeal

    2017-01-01

    This study, Seoul City shelter, you are trying to seek medical cooperation and cure rate increase proposal Yu fndings’s current situation and tuberculosis of homeless tuberculosis. Inspector, and has a total 591 people is targeted to implement an interview after acquiring utilization agreement in studies conducted chest X-ray photography. Of the interview questions, three or more protons, it is determined that the TB symptomatic conducted sputum examination, chest X-ray examination confrms the physician radiology, when sputum examination primarily chromatic fndings the double implemented and conducted by requesting the ship inspection also said inspection sputum acid-fast bacteria if it is true one, respectively. confrmed case result of checking whether there is a difference due to risk factors (Jb) at the chi square black, it was found that there is no statistically significant difference at 95% confidence level. (χ 2 =0.276, p>0.05), suspected case (Ac, Ae) results of examining whether there is a difference due to risk factors in chi square black, that there is a statistically significant difference at 99% confidence level is I found (χ 2 =9.414, p<0.01). The nature of the homeless tuberculosis screening and directed to the distance homeless specifc location are likely to evaluate the actual incidence low and aggressive or management needs, the rationale is allowed insufficient reality is. Through this research, future, for tuberculosis high risk tuberculosis patient, such as homeless to expand the tuberculosis screening of infectious tuberculosis patients in private medical institutions, and one-stop service that chest X-ray examination and sputum examination is carried out at the same time introduced immediately to prevent the inspection and examination, cure, and should establish a foundation that can be up to post administration

  6. Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis.

    Science.gov (United States)

    Acciavatti, Raymond J; Maidment, Andrew D A

    2011-11-01

    In digital breast tomosynthesis (DBT), a volumetric reconstruction of the breast is generated from a limited range of x-ray projections. One trade-off of DBT is resolution loss in the projections due to non-normal (i.e., oblique) x-ray incidence. Although degradation in image quality due to oblique incidence has been studied using empirical data and Monte Carlo simulations, a theoretical treatment has been lacking. The purpose of this work is to extend Swank's calculations of the transfer functions of turbid granular phosphors to oblique incidence. The model is ultimately used as a tool for optimizing the design of DBT detectors. A quantum-limited system and 20 keV x-rays are considered. Under these assumptions, the modulation transfer function (MTF) and noise power spectra (NPS) are derived using the diffusion approximation to the Boltzmann equation to model optical scatter within the phosphor. This approach is applicable to a nonstructured scintillator such as gadolinium oxysulfide doped with terbium (Gd(2)O(2)S:Tb), which is commonly used in breast imaging and which can reasonably approximate other detector materials. The detective quantum efficiency (DQE) is then determined from the Nishikawa formulation, where it is written as the product of the x-ray quantum detection efficiency, the Swank factor, and the Lubberts fraction. Transfer functions are calculated for both front- and back-screen configurations, which differ by positioning the photocathode at the exit or entrance point of the x-ray beam, respectively. In the front-screen configuration, MTF and DQE are found to have considerable angular dependence, while NPS is shown to vary minimally with projection angle. As expected, the high frequency MTF and DQE are degraded substantially at large angles. By contrast, all transfer functions for the back-screen configuration have the advantage of significantly less angular dependence. Using these models, we investigated the possibility for optimizing the design of

  7. Theoretically predicted soft x-ray emission and absorption spectra of graphitic-structured BC2N

    Science.gov (United States)

    Muramatsu, Yasuji

    Theoretical B K, C K and N K x-ray emission/absorption spectra of three possible graphitic-structured BC2N clusters are predicted based on the B2p-, C2p-, and N2p- density-of-states (DOS) calculated by discrete variational (DV)-X[alpha] molecular orbital calculations. Several prominent differences in DOS spectral features among BC2Ns, h-BN, and graphite are confirmed from comparison of calculated B2p-, C2p-, and N2p-DOS spectra. These variations in the spectra allow BC2N structures to be positively identified by high-resolution x-ray emission/absorption spectroscopy in the B K, C K, and N K regions.

  8. Correlation between Soft X-ray Absorption and Emission Spectra of the Nitrogen Atoms within Imidazolium-Based Ionic Liquids.

    Science.gov (United States)

    Horikawa, Yuka; Tokushima, Takashi; Takahashi, Osamu; Hoke, Hiroshi; Takamuku, Toshiyuki

    2016-08-04

    Soft X-ray absorption spectroscopy (XAS) has been performed on the N K-edge of two imidazolium-based ionic liquids (ILs), 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)amide ([C2mim][TFSA]) and 1-ethyl-3-methylimidazolium bromide ([C2mim][Br]), to clarify the electronic structures of the ILs. Soft X-ray emission spectroscopy (XES) has also been applied to the ILs by excitation at various X-ray energies according to the XAS spectra. It was possible to fully associate the XAS peaks with the XES peaks. Additionally, both XAS and XES spectra of the ILs were well reproduced by the theoretical spectra for a single-molecule model on [C2mim](+) and [TFSA](-) using density functional theory. The assignments for the XAS and XES peaks of the ILs were accomplished from both experimental and theoretical approaches. The theoretical XAS and XES spectra of [C2mim](+) and [TFSA](-) did not significantly depend on the conformations of the ions. The reproducibility of the theoretical spectra for the single-molecule model suggested that the interactions between the cations and anions are very weak in the ILs, thus scarcely influencing the electronic structures of the nitrogen atoms.

  9. PROBING WOLF–RAYET WINDS: CHANDRA/HETG X-RAY SPECTRA OF WR 6

    Energy Technology Data Exchange (ETDEWEB)

    Huenemoerder, David P.; Schulz, N. S. [Massachusetts Institute of Technology, Kavli Institute for Astrophysics and Space Research, 70 Vassar St., Cambridge, MA 02139 (United States); Gayley, K. G. [Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242 (United States); Hamann, W.-R.; Oskinova, L.; Shenar, T. [Institut für Physik und Astronomie, Universität Potsdam, Karl-Liebknecht-Str. 24/25, D-14476 Potsdam (Germany); Ignace, R. [Department of Physics and Astronomy, East Tennessee State University, Johnson City, TN 37614 (United States); Nichols, J. S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., MS 34, Cambridge, MA 02138 (United States); Pollock, A. M. T., E-mail: dph@space.mit.edu, E-mail: ken.gayley@gmail.com, E-mail: wrh@astro.physik.uni-potsdam.de, E-mail: lida@astro.physik.uni-potsdam.de, E-mail: shtomer@astro.physik.uni-potsdam.de, E-mail: ignace@mail.etsu.edu, E-mail: jnichols@cfa.harvard.edu [European Space Agency, ESAC, Apartado 78, E-28691 Villanueva de la Cañada (Spain)

    2015-12-10

    With a deep Chandra/HETGS exposure of WR 6, we have resolved emission lines whose profiles show that the X-rays originate from a uniformly expanding spherical wind of high X-ray-continuum optical depth. The presence of strong helium-like forbidden lines places the source of X-ray emission at tens to hundreds of stellar radii from the photosphere. Variability was present in X-rays and simultaneous optical photometry, but neither were correlated with the known period of the system or with each other. An enhanced abundance of sodium revealed nuclear-processed material, a quantity related to the evolutionary state of the star. The characterization of the extent and nature of the hot plasma in WR 6 will help to pave the way to a more fundamental theoretical understanding of the winds and evolution of massive stars.

  10. Sub-keV, subnanosecond measurements of x-ray spectra from laser-produced plasmas

    International Nuclear Information System (INIS)

    Kornblum, H.N.; Koppel, L.N.; Slivinsky, V.W.; Glaros, S.S.; Ahlstrom, H.G.; Larsen, J.T.

    1977-01-01

    As part of the effort to extend our x-ray diagnostic capabilities, we have made x-ray spectral measurements of laser-produced plasmas for photon energies down to 100 eV with a time response of 0.5 nsec. Fast, windowless x-ray diodes were used in conjunction with critical angle reflecting mirrors and thin filters for energy definition for two channels, 300 to 600 eV and 800 to 1300 eV. A third channel, using only an x-ray diode and filter, provided spectral information in the 100 to 300 eV region. Results from exploding pusher targets will be presented and compared with those of other diagnostic techniques and Lasnex calculations. Future expansion and modifications of the present system will be discussed

  11. Emission Line Spectra in the Soft X-ray Region 20 - 75 Angstroms

    Science.gov (United States)

    Lepson, J. K.; Beiersdorfer, P.; Chen, H.; Behar, E.; Kahn, S. M.

    2002-01-01

    As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EDIT-II, emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region were studied. Observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 Angstrom are presented to illustrate our work.

  12. Variations in cerium X-ray spectra and enhanced K-edge angiography

    International Nuclear Information System (INIS)

    Sato, Eiichi; Tanaka, Etsuro; Mori, Hidezo

    2005-01-01

    A cerium-target X-ray tube is useful in performing cone-beam K-edge angiography because K-series characteristic X-rays from the cerium target are absorbed effectively by iodine-based contrast media. The X-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode X-ray tube. The tube is a 1.0-mm-focus diode with a cerium target and a 0.5-mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively. Cerium Kα rays were selected out using a barium sulfate filter, and the X-ray intensities without filtering and with a barium sulfate filter were 209 and 16.8 μGy/s, respectively, at 1.0 m from the source with a tube voltage of 60 kV and a current of 0.40 mA. Angiography was performed with an X-ray film using the filter and iodine-based microspheres 15 μm in diameter. In the angiography of nonliving animals, we observed fine blood vessels approximately 100 μm in diameter with high contrasts. (author)

  13. New Spectral Model for Constraining Torus Covering Factors from Broadband X-Ray Spectra of Active Galactic Nuclei

    Science.gov (United States)

    Baloković, M.; Brightman, M.; Harrison, F. A.; Comastri, A.; Ricci, C.; Buchner, J.; Gandhi, P.; Farrah, D.; Stern, D.

    2018-02-01

    The basic unified model of active galactic nuclei (AGNs) invokes an anisotropic obscuring structure, usually referred to as a torus, to explain AGN obscuration as an angle-dependent effect. We present a new grid of X-ray spectral templates based on radiative transfer calculations in neutral gas in an approximately toroidal geometry, appropriate for CCD-resolution X-ray spectra (FWHM ≥ 130 eV). Fitting the templates to broadband X-ray spectra of AGNs provides constraints on two important geometrical parameters of the gas distribution around the supermassive black hole: the average column density and the covering factor. Compared to the currently available spectral templates, our model is more flexible, and capable of providing constraints on the main torus parameters in a wider range of AGNs. We demonstrate the application of this model using hard X-ray spectra from NuSTAR (3–79 keV) for four AGNs covering a variety of classifications: 3C 390.3, NGC 2110, IC 5063, and NGC 7582. This small set of examples was chosen to illustrate the range of possible torus configurations, from disk-like to sphere-like geometries with column densities below, as well as above, the Compton-thick threshold. This diversity of torus properties challenges the simple assumption of a standard geometrically and optically thick toroidal structure commonly invoked in the basic form of the unified model of AGNs. Finding broad consistency between our constraints and those from infrared modeling, we discuss how the approach from the X-ray band complements similar measurements of AGN structures at other wavelengths.

  14. Optimization of x-ray spectra in digital mammography through Monte Carlo simulations.

    Science.gov (United States)

    Cunha, D M; Tomal, A; Poletti, M E

    2012-04-07

    In this work, a Monte Carlo code was used to investigate the performance of different x-ray spectra in digital mammography, through a figure of merit (FOM), defined as FOM = CNR²/(¯)D(g), with CNR being the contrast-to-noise ratio in image and [Formula: see text] being the average glandular dose. The FOM was studied for breasts with different thicknesses t (2 cm ≤ t ≤ 8 cm) and glandular contents (25%, 50% and 75% glandularity). The anode/filter combinations evaluated were those traditionally employed in mammography (Mo/Mo, Mo/Rh, Rh/Rh), and a W anode combined with Al or K-edge filters (Zr, Mo, Rh, Pd, Ag, Cd, Sn), for tube potentials between 22 and 34 kVp. Results show that the W anode combined with K-edge filters provides higher values of FOM for all breast thicknesses investigated. Nevertheless, the most suitable filter and tube potential depend on the breast thickness, and for t ≥ 6 cm, they also depend on breast glandularity. Particularly for thick and dense breasts, a W anode combined with K-edge filters can greatly improve the digital technique, with the values of FOM up to 200% greater than that obtained with the anode/filter combinations and tube potentials traditionally employed in mammography. For breasts with t < 4 cm, a general good performance was obtained with the W anode combined with 60 μm of the Mo filter at 24-25 kVp, while 60 μm of the Pd filter provided a general good performance at 24-26 kVp for t = 4 cm, and at 28-30 and 29-31 kVp for t = 6 and 8 cm, respectively.

  15. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  16. Adjustable Grazing Incidence X-ray Optics with 0.5 Arc Second Resolution

    Science.gov (United States)

    Reid, Paul

    We seek to develop adjustable grazing incidence optics for x-ray astronomy. The goal of this development is thin, lightweight mirrors with angular resolution of 0.5 arc seconds, comparable to the Chandra X-ray Observatory. The new mirror design consists of thin segments of a Wolter-I grazing incidence mirror, with piezo-electric material deposited directly on the back surface of the mirror. Depositing a pattern of independently addressable electrodes on top of the piezoelectric material produces an array of independent piezo cells. Energizing a particular cell introduces a localized deformation in the mirror without the need for a reaction structure. By applying the appropriate voltage to the piezo cells, it is possible to correct mirror figure errors that result from mirror fabrication, gravity release, mounting, and thermal effects. Because the thin mirrors segments are lightweight, they can be densely nested to produce collecting area thirty times that of Chandra, on an affordably priced mission. This Supporting Technology program is a follow-on to an existing APRA program. In the existing program we demonstrated the first successful deposition of piezoelectric material on thermally formed glass substrates. We showed that the localized deformations produced by the piezo cells match finite element predictions, and the piezo cell adjustment range meets requirements necessary to achieve the desired figure correction. We have also shown through simulation that representative mirror figure errors can be corrected via modeled influence functions to achieve 0.5 arc sec imaging performance. This provides a firm foundation on which to develop further the technology. We will continue to optimize the deposition of thin piezoelectric films onto thermally formed glass and electroplated metal mirror segments to improve yield and manufacturability. We will deposit piezoelectric material onto conical mirror segments and demonstrate figure correction in agreement with prediction

  17. Comparison of simulated and measured spectra from an X-ray tube for the energies between 20 and 35 keV

    International Nuclear Information System (INIS)

    Yücel, M.; Emirhan, E.; Bayrak, A.; Ozben, C.S.; Yücel, E. Barlas

    2015-01-01

    Design and production of a simple and low cost X-ray imaging system that can be used for light industrial applications was targeted in the Nuclear Physics Laboratory of Istanbul Technical University. In this study, production, transmission and detection of X-rays were simulated for the proposed imaging device. OX/70-P dental tube was used and X-ray spectra simulated by Geant4 were validated by comparison with X-ray spectra measured between 20 and 35 keV. Relative detection efficiency of the detector was also determined to confirm the physics processes used in the simulations. Various time optimization tools were performed to reduce the simulation time

  18. X-ray spectra from magnetar candidates - III. Fitting SGR/AXP soft X-ray emission with non-relativistic Monte Carlo models

    NARCIS (Netherlands)

    Zane, S.; Rea, N.; Turolla, R.; Nobili, L.

    2009-01-01

    Within the magnetar scenario, the ‘twisted magnetosphere’ model appears very promising in explaining the persistent X-ray emission from soft gamma repeaters (SGRs) and anomalous X-ray pulsars (AXPs). In the first two papers of the series, we have presented a 3D Monte Carlo code for solving radiation

  19. Analysis of kiwi fruit (Accented deliciosa) by energy dispersive X-ray fluorescence spectra

    International Nuclear Information System (INIS)

    Oliveira, Ana Claudia S.; Oliveira, Marcia L. de; Silva, Lucia C.A.S.; Arthur, Valter; Almeida, Eduardo

    2011-01-01

    The search for a healthy life has led consumers to eat fruits and vegetables in place of manufactured products, however, the demand for minimally processed products has evolved rapidly. The kiwi has at least eight nutrients beneficial to health: calcium, magnesium, manganese, phosphorus, iron, potassium, sodium and has also high vitamin C, which has wide acceptance in consumer markets. Energy dispersive spectroscopy X-ray (EDX) is the analytical technique used for elemental analysis or chemical characterization of a sample. It is a variant of fluorescence spectroscopy X-ray based on the sample through an investigation of interactions between electromagnetic radiation and matter, analyzing X-rays emitted by matter in response to being struck by charged particles. The aim of this study were to determine potassium, calcium, iron and bromine (K, Ca, Fe and Br, respectively) present in kiwifruit using the technique of fluorescence X-ray energy dispersive (EDXRF). Kiwifruit were peeled, washed and cut into slices and freeze-dried. After drying the sample was held digestion and subsequent reading of the same equipment in the X-ray fluorescence energy dispersive (EDXRF). The results indicated that the contents of potassium, calcium, iron and bromine are present in kiwifruit as expected when compared to Brazilian Table of Food Composition. (author)

  20. Monte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectors

    Energy Technology Data Exchange (ETDEWEB)

    Moralles, M. [Centro do Reator de Pesquisas, Instituto de Pesquisas Energeticas e Nucleares, Caixa Postal 11049, CEP 05422-970, Sao Paulo SP (Brazil)], E-mail: moralles@ipen.br; Bonifacio, D.A.B. [Centro do Reator de Pesquisas, Instituto de Pesquisas Energeticas e Nucleares, Caixa Postal 11049, CEP 05422-970, Sao Paulo SP (Brazil); Bottaro, M.; Pereira, M.A.G. [Instituto de Eletrotecnica e Energia, Universidade de Sao Paulo, Av. Prof. Luciano Gualberto, 1289, CEP 05508-010, Sao Paulo SP (Brazil)

    2007-09-21

    Spectra of calibration sources and X-ray beams were measured with a cadmium telluride (CdTe) detector. The response function of the detector was simulated using the GEANT4 Monte Carlo toolkit. Trapping of charge carriers were taken into account using the Hecht equation in the active zone of the CdTe crystal associated with a continuous function to produce drop of charge collection efficiency near the metallic contacts and borders. The rise time discrimination is approximated by a cut in the depth of the interaction relative to cathode and corrections that depend on the pulse amplitude. The least-squares method with truncation was employed to unfold X-ray spectra typically used in medical diagnostics and the results were compared with reference data.

  1. Monte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectors

    Science.gov (United States)

    Moralles, M.; Bonifácio, D. A. B.; Bottaro, M.; Pereira, M. A. G.

    2007-09-01

    Spectra of calibration sources and X-ray beams were measured with a cadmium telluride (CdTe) detector. The response function of the detector was simulated using the GEANT4 Monte Carlo toolkit. Trapping of charge carriers were taken into account using the Hecht equation in the active zone of the CdTe crystal associated with a continuous function to produce drop of charge collection efficiency near the metallic contacts and borders. The rise time discrimination is approximated by a cut in the depth of the interaction relative to cathode and corrections that depend on the pulse amplitude. The least-squares method with truncation was employed to unfold X-ray spectra typically used in medical diagnostics and the results were compared with reference data.

  2. Package for Interactive Analysis of Line Emission (Analysis of UV-X-Ray High-Resolution Emission Spectra)

    Science.gov (United States)

    Hunter, Paul (Technical Monitor); Kashyap, Vinay

    2004-01-01

    The Package for Interactive Analysis of Line Emission (PINTofALE) is a suite of IDL routines designed to carry out spectroscopic analysis of high-resolution X-ray spectra. The current version is 1.5, and will shortly be upgraded to v2. A detailed description of the package, together with detailed documentation, example walk-throughs, science threads, and downloadable tar files, are available on-line.

  3. Extracting ion emission lines from femtosecond-laser plasma x-ray spectra heavily contaminated by spikes

    International Nuclear Information System (INIS)

    Gasilov, S. V.; Faenov, A. Ya.; Pikuz, T. A.; Villoresi, P.; Poletto, L.; Stagira, S.; Calegari, F.; Vozzi, C.; Nisoli, M.

    2007-01-01

    Nowadays charged-coupled device (CCD) detectors are widely used for the registration of multicharged ions x-ray spectra. These spectra are generated in a plasma during interaction of ultrashort, ultraintense laser pulses with solid targets. Strong parasitic radiation from the plasma affects CCD detectors and contaminates resulting spectra, so that spectral features can be completely covered by noise even during measurements with a very short accumulation time. In this work we propose a ''mean to median'' (M2M) algorithm for noise suppression in femtosecond laser plasma x-ray spectra. Series of spectra is necessary for the identification of corrupted data points by the developed method. The algorithm was tested with model spectra which reflect main features of experimental data. In practice we used it for extracting information about spectral lines of Ne-like Fe ions and He-like Al ions which allowed us to calculate plasma parameters. It is demonstrated that M2M method is able to clean spectra with more than 10% of corrupted pixels. Fluctuations in intensity of spectral lines induced by laser instability do not affect validity of the proposed method

  4. Starburst Galaxies: Hard X-ray spectra and contribution to the diffuse background

    Science.gov (United States)

    Gruber, Duane E.

    1993-01-01

    During the period of this grant two main tasks were performed: a determination of a selection criterion for starburst galaxies most likely to emit X-rays, and performance of a pilot study of the X-ray emission from nine such systems. Starburst galaxies may be expected to emit flat-spectrum X-ray at energies above 10 keV resulting from the various remnants of the short-lived massive stars which characterize the starburst. The investigation to determine the optimum sample resulted in a change from an X-ray selected (HEAO-2) sample to infrared selection based on the IRAS catalogue. A much broader sample thereby available for study, and selection could be limited to only the nearest objects and still obtain a reasonably large sample. A sample of 99 of the brightest infrared starburst galaxies was settled on for the X-ray survey. For a set of practical size, this was then reduced to a subset of 53, based on luminosity and nearness. X-ray emission from these objects was individually measured from the UCSD HEAO-1 all-sky survey in four energy bands between 13 keV to 160 keV. This data base consists of about 20 optical disk volumes. Net significance for the result was roughly two sigma, and a very hard spectral shape is indicated for the net spectrum of the surveyed galaxies. With the possibility of detection of the class, it was then felt worthwhile to examine fluxes from these sources in other archival data. This was performed with the HEAO-1 A2 data and the HEAO-2 (EINSTEIN) main archive and slew survey. Positive results were also obtained for the sample, but again at weak significance. With three independent measures of weak X-ray fluxes from nearby starburst galaxies, we wrote a letter to the Astrophysical Journal (enclosed) discussing these results and their likely significance, in particular, for the contribution to the cosmic diffuse x-ray background, perhaps as much as 25 percent.

  5. On the origin of power-law X-ray spectra of active galactic nuclei

    Science.gov (United States)

    Schlosman, I.; Shaham, J.; Shaviv, G.

    1984-01-01

    In the present analytical model for a power law X-ray continuum production in active galactic nuclei, the dissipation of turbulent energy flux above the accretion disk forms an optically thin transition layer with an inverted temperature gradient. The emitted thermal radiation has a power law spectrum in the 0.1-100 keV range, with a photon energy spectral index gamma of about 0.4-1.0. Thermal X-ray contribution from the layer is 5-10 percent of the total disk luminosity. The gamma value of 0.75 is suggested as a 'natural' power law index for Seyfert galaxies and QSOs.

  6. Studies of momentum transfer and X-ray spectra in a laser-produced plasma

    International Nuclear Information System (INIS)

    Leroy, Pierre

    Studies of momentum transfer from a ballistic pendulum appear to give satisfactory results for absorbed laser energies in excess of 200 mJ i.e. for fluxes in the 3.10 10 to 3.10 12 W.cm -2 range. A hard X-ray component attributed to fast electrons was revealed by an X-ray spectrometer with a PM system of greater sensitivity than PIN diodes. The laser energy is however too weak to enable studies to be conducted as a function of laser flux or measurements to be performed on targets of low Z [fr

  7. Fast spectral fitting of hard X-ray bremsstrahlung from truncated power-law electron spectra

    Czech Academy of Sciences Publication Activity Database

    Brown, J. C.; Kašparová, Jana; Massone, A.M.; Piana, M.

    2008-01-01

    Roč. 486, č. 3 (2008), s. 1023-1029 ISSN 0004-6361 R&D Projects: GA ČR GP205/06/P135 Institutional research plan: CEZ:AV0Z10030501 Keywords : sun flares * X-rays * gamma rays Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.153, year: 2008

  8. Determination of Al concentration in Al doped ZnO using Auger spectra excited by Mo X-rays

    International Nuclear Information System (INIS)

    Toth, J.; Koever, L.; Cserny, I.; Varga, D.

    2006-01-01

    Complete text of publication follows. A good conductor with excellent transparency is of crucial importance for the window layer of CIGS solar cells. Al doped ZnO is a good candidate for this purpose, its conductivity depends on the concentration and chemical state of the Al dopant atoms. It was demonstrated that the non-conventional XPS using Mo X-rays for excitation is a very sensitive tool for the detection of Al, P, Si [1, 2, 3]. The present paper compares the experimental ratios for Zn/Al photoinduced peak intensity ratios obtained using both Al and Mo X-ray excitations. The Mo excited Zn/Al intensity ratios can be determined with higher selectivity and sensitivity than the Zn/Al intensity ratios excited by Al X-rays. The experiments were performed with a hemispherical deflector electron spectrometer [4]. The chemical state of the Al was identified to be close to that in Al 2 O 3 . The atomic concentrations were determined using a calibration curve based on ZnO/Al samples with known composition of Al. The energy dependent efficiency of the electron spectrometer was determined comparing REELS spectra of Cu specimen to standard spectra measured by K. Goto (Nagoya Institute of Technology, Japan). For evaluation of the Al atomic concentrations from the measured photoelectron intensities the photoionisation cross-sections of Band et al [5] and the IMFP data of S. Tanuma et al [6] and C.J. Powell and A. Jablonski [7] were used. (author)

  9. Comparative Analysis and Variability of the Jovian X-Ray Spectra Detected by the Chandra and XMM-Newton Observatories

    Energy Technology Data Exchange (ETDEWEB)

    Hui, Yawei [ORNL; Schultz, David Robert [ORNL; Kharchenko, Vasili A [ORNL; Bhardwaj, Anil [Vikram Sarabhai Space Center, Trivandrum, India; Branduardi-Raymont, Graziella [University College, London; Stancil, Phillip C. [University of Georgia, Athens, GA; Cravens, Thomas E. E. [University of Kansas; Lisse, Carey M. [Johns Hopkins University; Dalgarno, A. [Harvard-Smithsonian Center for Astrophysics

    2010-01-01

    Expanding upon recent work, a more comprehensive spectral model based on charge exchange induced X-ray emission by ions precipitating into the Jovian atmosphere is used to provide new understanding of the polar auroras. In conjunction with the Xspec spectral fitting software, the model is applied to analyze observations from both Chandra and XMM-Newton by systematically varying the initial precipitating ion parameters to obtain the best fit model for the observed spectra. In addition to the oxygen and sulfur ions considered previously, carbon is included to discriminate between solar wind and Jovian magnetospheric ion origins, enabled by the use of extensive databases of both atomic collision cross sections and radiative transitions. On the basis of fits to all the Chandra observations, we find that carbon contributes negligibly to the observed polar X-ray emission suggesting that the highly accelerated precipitating ions are of magnetospheric origin. Most of the XMM-Newton fits also favor this conclusion with one exception that implies a possible carbon contribution. Comparison among all the spectra from these two observatories in light of the inferred initial energies and relative abundances of precipitating ions from the modeling show that they are significantly variable in time (observation date) and space (north and south polar X-ray auroras).

  10. Low energy X-ray spectra measured with a mercuric iodide energy dispersive spectrometer in a scanning electron microscope

    Science.gov (United States)

    Iwanczyk, J. S.; Dabrowski, A. J.; Huth, G. C.; Bradley, J. G.; Conley, J. M.

    1986-01-01

    A mercuric iodide energy dispersive X-ray spectrometer, with Peltier cooling provided for the detector and input field effect transistor, has been developed and tested in a scanning electron microscope. X-ray spectra were obtained with the 15 keV electron beam. An energy resolution of 225 eV (FWHM) for Mn-K(alpha) at 5.9 keV and 195 eV (FWHM) for the Mg-K line at 1.25 keV has been measured. Overall system noise level was 175 eV (FWHM). The detector system characterization with a carbon target demonstrated good energy sensitivity at low energies and lack of significant spectral artifacts at higher energies.

  11. X-ray spectra and electronic structure of the Ca3Ga2Ge3О12 compound

    Science.gov (United States)

    Shcherba, I. D.; Kostyk, L. V.; Noga, H.; Bekenov, L. V.; Uskokovich, D.; Jatsyk, B. M.

    2017-09-01

    The band structure of Ca3Ga2Ge3О12 with the garnet structure has been determined for the first time by X-ray emission and photoelectron spectroscopy. It has been established that the bottom of the valence band is formed by Ge d states, which are not dominant in the chemical bonding. Strong hybridization of oxygen 2s states with 4p states of Ga and Ge revealed by the presence of an extra structure in the X-ray emission spectra has been found. The middle of the valence band has been demonstrated to be occupied by d states of Ga, while Ga and Ge 4рstates with a considerable admixture of oxygen 2p states form the top of the valence band.

  12. Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Slit-Jaw Imaging System

    Science.gov (United States)

    Wilkerson, P.; Champey, P. R.; Winebarger, A. R.; Kobayashi, K.; Savage, S. L.

    2017-12-01

    The Marshall Grazing Incidence X-ray Spectrometer is a NASA sounding rocket payload providing a 0.6 - 2.5 nm spectrum with unprecedented spatial and spectral resolution. The instrument is comprised of a novel optical design, featuring a Wolter1 grazing incidence telescope, which produces a focused solar image on a slit plate, an identical pair of stigmatic optics, a planar diffraction grating and a low-noise detector. When MaGIXS flies on a suborbital launch in 2019, a slit-jaw camera system will reimage the focal plane of the telescope providing a reference for pointing the telescope on the solar disk and aligning the data to supporting observations from satellites and other rockets. The telescope focuses the X-ray and EUV image of the sun onto a plate covered with a phosphor coating that absorbs EUV photons, which then fluoresces in visible light. This 10-week REU project was aimed at optimizing an off-axis mounted camera with 600-line resolution NTSC video for extremely low light imaging of the slit plate. Radiometric calculations indicate an intensity of less than 1 lux at the slit jaw plane, which set the requirement for camera sensitivity. We selected a Watec 910DB EIA charge-coupled device (CCD) monochrome camera, which has a manufacturer quoted sensitivity of 0.0001 lux at F1.2. A high magnification and low distortion lens was then identified to image the slit jaw plane from a distance of approximately 10 cm. With the selected CCD camera, tests show that at extreme low-light levels, we achieve a higher resolution than expected, with only a moderate drop in frame rate. Based on sounding rocket flight heritage, the launch vehicle attitude control system is known to stabilize the instrument pointing such that jitter does not degrade video quality for context imaging. Future steps towards implementation of the imaging system will include ruggedizing the flight camera housing and mounting the selected camera and lens combination to the instrument structure.

  13. Mass attenuation coefficient (μ/ρ), effective atomic number (Zeff) and measurement of x-ray energy spectra using based calcium phosphate biomaterials: a comparative study

    International Nuclear Information System (INIS)

    Fernandes Z, M. A.; Da Silva, T. A.; Nogueira, M. S.; Goncalves Z, E.

    2015-10-01

    In dentistry, alveolar bone regeneration procedures using based calcium phosphate biomaterials have been shown effective. However,there are not reports in the literature of studies the interaction of low energy radiation in these biomaterials used as attenuator and not being then allowed a comparison between the theoretical values and experimental.The objective of this study was to determine the interaction of radiation parameters of four dental biomaterials - BioOss, Cerasorb M Dental, Straumann Boneceramic and Osteogen for diagnostic radiology qualities. As a material and methods, the composition of the biomaterials was determined by the analytical techniques. The samples with 0.181 cm to 0,297 cm thickness were experimentally used as attenuators for the measurement of the transmitted X-rays spectra in X-ray equipment with 50 to 90 kV range by spectrometric system comprising the Cd Te detector. After this procedure, the mass attenuation coefficient, the effective atomic number were determined and compared between all the specimens analyzed, using the program WinXCOM in the range of 10 to 200 keV. In all strains examined observed that the energy spectrum of x-rays transmitted through the BioOss has the mean energy slightly smaller than the others biomaterials for close thickness. The μ/ρ and Z eff of the biomaterials showed its dependence on photon energy and atomic number of the elements of the material analyzed. It is concluded according to the methodology employed in this study that the measurements of x-ray spectrum, μ/ρ and Z eff using biomaterials as attenuators confirmed that the thickness, density, composition of the samples, the incident photon energy are factors that determine the characteristics of radiation in a tissue or equivalent material. (Author)

  14. Correction of diagnostic x-ray spectra measured with CdTe and CdZnTe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, M. [Osaka Univ., Suita (Japan). Medical School; Kanamori, H.; Toragaito, T.; Taniguchi, A.

    1996-07-01

    We modified the formula of stripping procedure presented by E. Di. Castor et al. We added the Compton scattering and separated K{sub {alpha}} radiation of Cd and Te (23 and 27keV, respectively). Using the new stripping procedure diagnostic x-ray spectra (object 4mm-Al) of tube voltage 50kV to 100kV for CdTe and CdZnTe detectors are corrected with comparison of those spectra for the Ge detector. The corrected spectra for CdTe and CdZnTe detectors coincide with those for Ge detector at lower tube voltage than 70kV. But the corrected spectra at higher tube voltage than 70kV do not coincide with those for Ge detector. The reason is incomplete correction for full energy peak efficiencies of real CdTe and CdZnTe detectors. (J.P.N.)

  15. Autonomous Modelling of X-ray Spectra Using Robust Global Optimization Methods

    Science.gov (United States)

    Rogers, Adam; Safi-Harb, Samar; Fiege, Jason

    2015-08-01

    The standard approach to model fitting in X-ray astronomy is by means of local optimization methods. However, these local optimizers suffer from a number of problems, such as a tendency for the fit parameters to become trapped in local minima, and can require an involved process of detailed user intervention to guide them through the optimization process. In this work we introduce a general GUI-driven global optimization method for fitting models to X-ray data, written in MATLAB, which searches for optimal models with minimal user interaction. We directly interface with the commonly used XSPEC libraries to access the full complement of pre-existing spectral models that describe a wide range of physics appropriate for modelling astrophysical sources, including supernova remnants and compact objects. Our algorithm is powered by the Ferret genetic algorithm and Locust particle swarm optimizer from the Qubist Global Optimization Toolbox, which are robust at finding families of solutions and identifying degeneracies. This technique will be particularly instrumental for multi-parameter models and high-fidelity data. In this presentation, we provide details of the code and use our techniques to analyze X-ray data obtained from a variety of astrophysical sources.

  16. On the determination of stress profiles in expanded austenite by grazing incidence X-ray diffraction and successive layer removal

    DEFF Research Database (Denmark)

    Fernandes, Frederico Augusto Pires; Christiansen, Thomas L.; Winther, Grethe

    2015-01-01

    Surface layers of expanded austenite resulting from nitriding typically exhibit large gradients in residual stress and composition. Evaluation of residual-stress profiles is explored by means of grazing incidence X-ray diffraction (GI-XRD), probing shallow depths, combined with successive layer...

  17. Multiple scattering in grazing-incidence X-ray diffraction : Impact on lattice-constant determination in thin films

    NARCIS (Netherlands)

    Resel, Roland; Bainschab, Markus; Pichler, Alexander; Dingemans, T.J.; Simbrunner, Clemens; Stangl, Julian; Salzmann, Ingo

    2016-01-01

    Dynamical scattering effects are observed in grazing-incidence X-ray diffraction experiments using an organic thin film of 2,2′:6′,2′′-ternaphthalene grown on oxidized silicon as substrate. Here, a splitting of all Bragg peaks in the out-of-plane direction (z-direction) has been observed, the

  18. Grazing incidence reflectivity and total electron yield effects in soft x-ray absorption spectroscopy

    NARCIS (Netherlands)

    Alders, D; Hibma, T; Sawatzky, G.A; Cheung, K.C.; van Dorssen, G.E.; Roper, M.D.; Padmore, H.A.; van der Laan, G.; Vogel, J; Sacchi, M.

    1997-01-01

    We report on a study of grazing incidence absorption and reflection spectra of NiO in the region of the Ni 2p edge. The aim is to evaluate the distortion of the near edge spectrum by the critical angle behavior of individual components within the spectrum. This can be used to improve the separation

  19. Numerical controlled diamond fly cutting machine for grazing incidence X-ray reflection mirrors

    International Nuclear Information System (INIS)

    Uchida, Fumihiko; Moriyama, Shigeo; Seya, Eiiti

    1992-01-01

    Synchrotron radiation has reached the stage of practical use, and the application to the wide fields that support future advanced technologies such as spectroscopy, the structural analysis of matters, semiconductor lithography and medical light source is expected. For the optical system of the equipment utilizing synchrotron radiation, the total reflection mirrors of oblique incidence are used for collimating and collecting X-ray. In order to restrain their optical aberration, nonspherical shape is required, and as the manufacturing method with high precision for nonspherical mirrors, a numerically controlled diamond cutting machine was developed. As for the cutting of soft metals with diamond tools, the high precision machining of any form can be done by numerical control, the machining time can be reduced as compared with grinding, and the cooling effect is large in metals. The construction of the cutting machine, the principle of machining, the control system, the method of calculating numerical control data, the investigation of machinable forms and the result of evaluation are reported. (K.I.)

  20. Applications of a glazing incidence X-ray fluorescence analysis to forensic samples

    International Nuclear Information System (INIS)

    Ninomiya, Toshio; Nomura, Shigeaki; Taniguchi, Kazuo; Ikeda, Shigero.

    1995-01-01

    A glazing incidence X-ray fluorescence analysis (GIXF) has been applied to forensic samples: a counterfeit 100-dollar bill, fragments of polyvinyl tapes, a trace of semen, illegal drugs, fingerprints and fake V.S.O.P brandy. Strontium could not be detected on the magnet-respondent letter of the counterfeit bill and Br was detected on the magnet-nonrespondent part of the counterfeit bill, while such phenomena could not be noticed on a true bill. Fragments of black vinyl tapes related to a sexual assault case could be discriminated from each other. Zinc as a characteristic ingredient could be detected in a trace of semen. Bromine was detected in each of what is called a pure methamphetamine crystal and K, Ca, Fe, Zn etc. were detected in heroin powders. Lead was sharply detected in gunshot residues attached to a finger after gunfiring. Sulfur as a contaminant was abundant in fake V.S.O.P brandy, while no S was detected in genuine V.S.O.P brandy. (author)

  1. Applications of a glazing incidence X-ray fluorescence analysis to forensic samples

    Energy Technology Data Exchange (ETDEWEB)

    Ninomiya, Toshio [Hyogo Prefecture, Kobe (Japan). Forensic Science Lab.; Nomura, Shigeaki; Taniguchi, Kazuo; Ikeda, Shigero

    1995-06-01

    A glazing incidence X-ray fluorescence analysis (GIXF) has been applied to forensic samples: a counterfeit 100-dollar bill, fragments of polyvinyl tapes, a trace of semen, illegal drugs, fingerprints and fake V.S.O.P brandy. Strontium could not be detected on the magnet-respondent letter of the counterfeit bill and Br was detected on the magnet-nonrespondent part of the counterfeit bill, while such phenomena could not be noticed on a true bill. Fragments of black vinyl tapes related to a sexual assault case could be discriminated from each other. Zinc as a characteristic ingredient could be detected in a trace of semen. Bromine was detected in each of what is called a pure methamphetamine crystal and K, Ca, Fe, Zn etc. were detected in heroin powders. Lead was sharply detected in gunshot residues attached to a finger after gunfiring. Sulfur as a contaminant was abundant in fake V.S.O.P brandy, while no S was detected in genuine V.S.O.P brandy. (author).

  2. Analysis of crystalline phases in airborne particulates by grazing incidence X-ray diffractometry.

    Science.gov (United States)

    Ozaki, Kana; Hanatani, Toshikazu; Nakamura, Toshihiro

    2005-07-01

    Amounts of crystalline phases of airborne particulates collected on a silicon wafer (10 x 10 mm) using a high-volume air sampler were analyzed by grazing incidence X-ray diffractometry (GIXD). Airborne particulates were classified into five size ranges (1.09-10.5 microm) with a cascade impactor attached on the sampling ports of the high-volume air sampler. GIXD was used throughout this analysis to obtain better sensitivity for small amounts of airborne particulates on the silicon wafer. Calibration standards on the silicon wafer for the diffractometric determination were prepared by the suspension droplet method of the crystalline standards dispersed in cyclohexane. Analytical lines were (020) for gypsum, (101) for quartz, (104) for calcite, (200) for halite, and (110) for sal ammoniac. The sample and the calibrating standards were heated at 350 degrees C for 2 h to avoid mutual interference with gypsum (041 and 221) when calcite and halite were determined. The GIXD method enables us to determine 0.23-13.2 microg of gypsum, quartz, calcite, halite and sal ammoniac in 0.110-0.233 mg of airborne particulates on the silicon wafer.

  3. Response of the 'patient dose calibrator' chamber for incident positions and sizes of X-ray fields

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Abrantes, Marcos Eugenio S.; Ferreira, Flavia C. Bastos; Lacerda, Marco A. de Souza; Alonso, Thessa C.; Silva, Teogenes A. da; Oliveira, Paulo Marcio C.

    2009-01-01

    The evaluation of patient doses is an important tool for optimizing radiodiagnostic medical procedures with conventional X-ray equipment and for improving the quality of the radiographic image. The Patient Dose Calibrator (PDC) chamber is a dosimetric instrument that is used in the evaluation of the air kerma-area product (P KA ) quantity aiming the reduction of patient doses. The objective this work was to study the P KA variation caused by different field incident positions and sizes of the X-ray beam on the PDC chamber. Results showed that the PDC chamber has repeatability lower than 0.6%, beam position dependence of 3% and linearity response within ± 6%; these characteristics are to be taken into account during evaluation of the radiological protection conditions of conventional x-ray equipment. (author)

  4. Grazing Incidence angle X-ray Diffraction of implanted stainless steel: comparison between simulated data and experimental data

    International Nuclear Information System (INIS)

    Dudognon, J.; Vayer, M.; Pineau, A.; Erre, R.

    2006-01-01

    Austenitic stainless steel was implanted with specific elements using specific conditions. The goal of this studies was to compare the predicted structural modifications within the implanted layer with the experimental ones observed by Grazing Incidence angle X-ray Diffraction (GIXD).During ion implantation implanted austenite steel layer undergoes modifications such as austenite lattice expansion, ferrite apparition and structure destruction. The X-ray diffraction austenite peak shape was predicted using the concentration depth profile of implanted element, the information depth profile of diffracted intensity and a linear relationship between implanted element concentration and lattice parameter. Experimental and predicted austenite X-ray diffraction peaks are in good accordance as long as the implanted layer contents mainly austenite. Whatever the nature of implanted element, ferrite appears above a given threshold of incoming energy amount. Moreover, the structure of the implanted layer is destroyed above a given amount of incoming energy

  5. Indirect measure of X-rays spectra using TLDs; Medicion indirecta de espectros de rayos X utilizando TLDs

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, X5016LEA Cordoba (Argentina)

    2011-10-15

    A methodology of indirect measure of X-rays spectra, emitted by conventional tubes, was developed recently and its feasibility verified in the first place by Monte Carlo simulations. For that case is intended to measure, by means of plastic scintillators, attenuation curves of dispersed beams previously. In this work were carried out measurements of attenuation curves with thermoluminescent dosimeters (TLD) to verify the kindness of the indirect measure method. The attenuation curve was also measured using an ionization chamber brand Capintec (model 192) with the purpose of making a comparison. The results of the attenuation curve measured with both dosimeters present a good resolution inside the statistical fluctuations and the spectral reconstruction using diverse parametric functions is carried out in a quick and simple way with excellent resolutions in the functional form. For this reconstruction method are of fundamental importance the following properties of the used dosimeter: in the first place the repetition of the measures, property that could check; in second place the precision of the measured data and lastly the dosimeter response, this is, the increase of the thermoluminescent signal before an increase of the photons flow of X-rays. This parameter is the gradient of the curve thermoluminescent signal versus the dose imparted to the dosimeter. The measures were realized with a generator of X-rays brand Kevex provided of a conventional tube with tungsten anti cathode that polarizes with high tension to a maximum value of 50 kV and current of 0.5 ma. (Author)

  6. X-Ray Emitting GHz-Peaked Spectrum Galaxies: Testing a Dynamical-Radiative Model with Broad-Band Spectra

    Energy Technology Data Exchange (ETDEWEB)

    Ostorero, L.; /Turin U. /INFN, Turin; Moderski, R.; /Warsaw, Copernicus Astron. Ctr. /KIPAC, Menlo Park; Stawarz, L.; /KIPAC, Menlo Park /Jagiellonian U., Astron. Observ.; Diaferio, A.; /Turin U. /INFN, Turin; Kowalska, I.; /Warsaw U. Observ.; Cheung, C.C.; /NASA, Goddard /Naval Research Lab, Wash., D.C.; Kataoka, J.; /Waseda U., RISE; Begelman, M.C.; /JILA, Boulder; Wagner, S.J.; /Heidelberg Observ.

    2010-06-07

    In a dynamical-radiative model we recently developed to describe the physics of compact, GHz-Peaked-Spectrum (GPS) sources, the relativistic jets propagate across the inner, kpc-sized region of the host galaxy, while the electron population of the expanding lobes evolves and emits synchrotron and inverse-Compton (IC) radiation. Interstellar-medium gas clouds engulfed by the expanding lobes, and photoionized by the active nucleus, are responsible for the radio spectral turnover through free-free absorption (FFA) of the synchrotron photons. The model provides a description of the evolution of the GPS spectral energy distribution (SED) with the source expansion, predicting significant and complex high-energy emission, from the X-ray to the {gamma}-ray frequency domain. Here, we test this model with the broad-band SEDs of a sample of eleven X-ray emitting GPS galaxies with Compact-Symmetric-Object (CSO) morphology, and show that: (i) the shape of the radio continuum at frequencies lower than the spectral turnover is indeed well accounted for by the FFA mechanism; (ii) the observed X-ray spectra can be interpreted as non-thermal radiation produced via IC scattering of the local radiation fields off the lobe particles, providing a viable alternative to the thermal, accretion-disk dominated scenario. We also show that the relation between the hydrogen column densities derived from the X-ray (N{sub H}) and radio (N{sub HI}) data of the sources is suggestive of a positive correlation, which, if confirmed by future observations, would provide further support to our scenario of high-energy emitting lobes.

  7. X-ray Emitting GHz-Peaked Spectrum Galaxies: Testing a Dynamical-Radiative Model with Broad-Band Spectra

    International Nuclear Information System (INIS)

    Ostorero, L.; Moderski, R.; Stawarz, L.; Diaferio, A.; Kowalska, I.; Cheung, C.C.; Kataoka, J.; Begelman, M.C.; Wagner, S.J.

    2010-01-01

    In a dynamical-radiative model we recently developed to describe the physics of compact, GHz-Peaked-Spectrum (GPS) sources, the relativistic jets propagate across the inner, kpc-sized region of the host galaxy, while the electron population of the expanding lobes evolves and emits synchrotron and inverse-Compton (IC) radiation. Interstellar-medium gas clouds engulfed by the expanding lobes, and photoionized by the active nucleus, are responsible for the radio spectral turnover through free-free absorption (FFA) of the synchrotron photons. The model provides a description of the evolution of the GPS spectral energy distribution (SED) with the source expansion, predicting significant and complex high-energy emission, from the X-ray to the γ-ray frequency domain. Here, we test this model with the broad-band SEDs of a sample of eleven X-ray emitting GPS galaxies with Compact-Symmetric-Object (CSO) morphology, and show that: (i) the shape of the radio continuum at frequencies lower than the spectral turnover is indeed well accounted for by the FFA mechanism; (ii) the observed X-ray spectra can be interpreted as non-thermal radiation produced via IC scattering of the local radiation fields off the lobe particles, providing a viable alternative to the thermal, accretion-disk dominated scenario. We also show that the relation between the hydrogen column densities derived from the X-ray (N H ) and radio (N HI ) data of the sources is suggestive of a positive correlation, which, if confirmed by future observations, would provide further support to our scenario of high-energy emitting lobes.

  8. Interpretation of x-ray absorption spectra in compounds with configurational disorder

    International Nuclear Information System (INIS)

    Kuzmin, A.; Dalba, G.; Fornasini, P.; Rocca, F.; Sipr, O.

    2005-01-01

    Full text: X-ray absorption spectroscopy (EXAFS and XANES) provides with unique information on electronic, atomic and dynamic structure of materials. Standard EXAFS and XANES analysis is based on relatively simple structural models as Gaussian / normal distribution. However, there are many compounds as glasses and nanocrystalline materials in which atoms of the same type occupy structural sites with different local environments. Therefore, special approach is required to access properly the case of configurational disorder. In this work we present recent developments for such problem

  9. X-Ray Absorption Spectra of Water from First Principles Calculations

    International Nuclear Information System (INIS)

    Prendergast, David; Galli, Giulia

    2006-01-01

    We present a series of ab initio calculations of the x-ray absorption cross section (XAS) of ice and liquid water at ambient conditions. Our results show that all available experimental data and theoretical results are consistent with the standard model of the liquid as comprising molecules with approximately four hydrogen bonds. Our simulations of ice XAS including the lowest lying excitonic state are in excellent agreement with experiment and those of a quasitetrahedral model of water are in reasonable agreement with recent measurements. Hence we propose that the standard, quasitetrahedral model of water, although approximate, represents a reasonably accurate description of the local structure of the liquid

  10. Processing and quantification of x-ray energy dispersive spectra in the Analytical Electron Microscope

    International Nuclear Information System (INIS)

    Zaluzec, N.J.

    1988-08-01

    Spectral processing in x-ray energy dispersive spectroscopy deals with the extraction of characteristic signals from experimental data. In this text, the four basic procedures for this methodology are reviewed and their limitations outlined. Quantification, on the other hand, deals with the interpretation of the information obtained from spectral processing. Here the limitations are for the most part instrumental in nature. The prospects of higher voltage operation does not, in theory, present any new problems and may in fact prove to be more desirable assuming that electron damage effects do not preclude analysis. 28 refs., 6 figs

  11. Pulsator-like Spectra from Ultraluminous X-Ray Sources and the Search for More Ultraluminous Pulsars

    Energy Technology Data Exchange (ETDEWEB)

    Pintore, F.; Mereghetti, S. [INAF-IASF Milano, via E. Bassini 15, I-20133 Milano (Italy); Zampieri, L. [INAF-Osservatorio Astronomico di Padova, Vicolo dell’Osservatorio 5, I-35122 Padova (Italy); Stella, L.; Israel, G. L. [INAF—Osservatorio astronomico di Roma, Via Frascati 44, I-00078, Monteporzio Catone (Italy); Wolter, A. [INAF, Osservatorio Astronomico di Brera, via Brera 28, I-20121 Milano (Italy)

    2017-02-10

    Ultraluminous X-ray sources (ULXs) are a population of extragalactic objects whose luminosity exceeds the Eddington limit for a 10 M {sub ⊙} black hole (BH). Their properties have been widely interpreted in terms of accreting stellar-mass or intermediate-mass BHs. However at least three neutron stars (NSs) have been recently identified in ULXs through the discovery of periodic pulsations. Motivated by these findings we studied the spectral properties of a sample of bright ULXs using a simple continuum model which was extensively used to fit the X-ray spectra of accreting magnetic NSs in the Galaxy. We found that such a model, consisting of a power-law with a high-energy exponential cut-off, fits most of the ULX spectra analyzed here very well, at a level comparable to that of models involving an accreting BH. On these grounds alone we suggest that other non-pulsating ULXs may host NSs. We also found that above 2 keV the spectrum of known pulsating ULXs is harder than that of the majority of the other ULXs of the sample, with only IC 342 X-1 and Ho IX X-1 displaying spectra of comparable hardness. We thus suggest that these two ULXs may host an accreting NS and encourage searches for periodic pulsations in the flux.

  12. X-ray Reflected Spectra from Accretion Disk Models. III. A Complete Grid of Ionized Reflection Calculations

    Science.gov (United States)

    Garcia, J.; Dauser, T.; Reynolds, C. S.; Kallman, T. R.; McClintock, J. E.; Wilms, J.; Ekmann, W.

    2013-01-01

    We present a new and complete library of synthetic spectra for modeling the component of emission that is reflected from an illuminated accretion disk. The spectra were computed using an updated version of our code xillver that incorporates new routines and a richer atomic data base. We offer in the form of a table model an extensive grid of reflection models that cover a wide range of parameters. Each individual model is characterized by the photon index Gamma of the illuminating radiation, the ionization parameter zeta at the surface of the disk (i.e., the ratio of the X-ray flux to the gas density), and the iron abundance A(sub Fe) relative to the solar value. The ranges of the parameters covered are: 1.2 total of 720 reflection spectra are provided in a single FITS file suitable for the analysis of X-ray observations via the atable model in xspec. Detailed comparisons with previous reflection models illustrate the improvements incorporated in this version of xillver.

  13. Structure of the X-ray photoelectron spectra of fluorides and oxides of lanthanides connected with the dynamic effect

    International Nuclear Information System (INIS)

    Teterin, Yu.A.; Teterin, A.Yu.; Lebedev, A.M.; Utkin, I.O.; Nikitin, A.S.

    1998-01-01

    Impact of dynamic effect on the fine structure of the X-ray electron spectra of the lanthanide oxides and fluorides is considered. Significant complication of the Ln4p-electrons occurs due to interaction of configurations of the basic single-hole and additional two-hole finite states of the 4p 5 4d 10 4f n ↔ 4p 6 4d 8 4f n+1 type. Impact of the atoms nature of the nearest surrounding of the lanthanides ions on the parameters of such fine structure is evaluated [ru

  14. Study of unfolding methods for X-ray spectra obtained with CDTE detectors in the mammography energy range

    Energy Technology Data Exchange (ETDEWEB)

    Querol, A.; Gallardo, S.; Rodenas, J.; Verdu, G.; Barrachina, T. [Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Cami de Vera, s/n 46022 Valencia (Spain)

    2010-07-01

    Quality control parameters for an X-ray tube strongly depend on the accurate knowledge of the primary spectrum, but it is difficult to obtain it experimentally by direct measurements. Indirect spectrometry techniques such as Compton scattering can be used in X-ray spectrum assessment avoiding the pile-up effect in detectors. However, an unfolding method is required for this kind of measurements. In previous works, a methodology to assess primary X-ray spectra in the diagnostic energy range by means of the Compton scattering technique has been analysed. This methodology included a Monte Carlo simulation model, using the MCNP5 code, of the actual experimental set-up providing a Pulse Height Distribution (PHD) for a given primary spectrum. It reproduced the interaction of photons and electrons with the Compton spectrometer and with a High Purity Germanium detector. In this work, a CdTe detector is proposed instead of the HP Germanium. CdTe detector does not require a liquid nitrogen cooling system, but its resolution is poor for the same energy range and its efficiency comes down for energies greater than 55 keV being 70% at 90 keV. In despite of these disadvantages, CdTe detector has been considered due to its low cost and easy handling and portability. The model can provide a PHD and a Response Matrix, for different X-ray spectra, taken from the IPEM 78 catalogue. The primary spectrum can be estimated applying the MTSVD (Modified Truncated Singular Value Decomposition) and the Tikhonov unfolding method. Both unfolding methods cause some loss of information on the reconstructed primary spectra. In this paper, a comparison of the ability to obtain primary spectra using both MTSVD and Tikhonov unfolding methods has been done. As well a sensitivity analysis in order to test the proposed unfolding methods when they are applied to PHDs obtained with the MCNP model has been developed. A variation on parameters such as target materials and voltages over the mammography

  15. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-07-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1-20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40-120 kVp and 0.5-1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.

  16. Revisiting the total ion yield x-ray absorption spectra of liquid water microjets

    Energy Technology Data Exchange (ETDEWEB)

    Saykally, Richard J; Cappa, Chris D.; Smith, Jared D.; Wilson, Kevin R.; Saykally, Richard J.

    2008-02-16

    Measurements of the total ion yield (TIY) x-ray absorption spectrum (XAS) of liquid water by Wilson et al. (2002 J. Phys.: Condens. Matter 14 L221 and 2001 J. Phys. Chem. B 105 3346) have been revisited in light of new experimental and theoretical efforts by our group. Previously, the TIY spectrum was interpreted as a distinct measure of the electronic structure of the liquid water surface. However, our new results indicate that the previously obtained spectrum may have suffered from as yet unidentified experimental artifacts. Although computational results indicate that the liquid water surface should exhibit a TIY-XAS that is fundamentally distinguishable from the bulk liquid XAS, the new experimental results suggest that the observable TIY-XAS is actually nearly identical in appearance to the total electron yield (TEY-)XAS, which is a bulk probe. This surprising similarity between the observed TIY-XAS and TEY-XAS likely results from large contributions from x-ray induced electron stimulated desorption of ions, and does not necessarily indicate that the electronic structure of the bulk liquid and liquid surface are identical.

  17. A microbeam grazing-incidence approach to L-shell x-ray fluorescence measurements of lead concentration in bone and soft tissue phantoms.

    Science.gov (United States)

    Gherase, Mihai Raul; Al-Hamdani, Summer

    2018-02-06

    L-shell x-ray fluorescence (LXRF) is a non-invasive approach to lead (Pb) concentration measurements in the human bone. The first studies were published in the early 1980s. In the same period the K-shell x-ray fluorescence (KXRF) method using a Cd-109 radionuclide source was developed and later improved and refined. Lower sensitivity and calibration difficulties associated with the LXRF method led the KXRF to be the most adopted method for in vivo human bone Pb studies. In the present study a microbeam-based grazing-incidence approach to Pb LXRF measurements was investigated. The microbeam produced by an integrated x-ray tube and polycapillary x-ray lens (PXL) unit was used to excite cylindrical plaster-of-Paris (poP) bone phantoms doped with Pb in seven concentrations: 0, 8, 16, 26, 34, 59, and 74 µg/g. Two 1 mm- and 3 mm-thick cylindrical shell soft tissue phantoms were made out of polyoxymethylene (POM) plastic. Three bone-soft tissue phantom sets corresponding to the 0, 1, and 3 mm POM thickness values resulted. Each phantom was placed between the microbeam and the detector; its position was controlled using a positioning stage. Small steps (0.1-0.5 mm) and short 30 s x-ray spectra acquisitions were used to find the optimal phantom position according to the maximum observed Sr Kα peak height. At the optimal geometry, five 180 s x-ray spectra were acquired for each phantom set. Calibration lines were obtained using the fitted peak heights of the two observed Pb Lα and Pb Lβ peaks. The lowest detection limit (DL) values were (2.9±0.2), (4.9±0.3), and (23±3) µg/g, respectively. The order of magnitude of the absorbed radiation dose in the POM plastic for the 180 s irradiation was estimated to be <1 mGy. The results are superior to a relatively recently-published LXRF phantom study and show promise for future designs of in vivo LXRF measurements. Creative Commons Attribution license.

  18. Smoothing X-ray spectra with regression splines and fast Fourier transform; Wygladzanie widm promieniowania X metodami regresyjnych funkcji sklejanych i szybkiej transformaty Fouriera

    Energy Technology Data Exchange (ETDEWEB)

    Antoniak, W.; Urbanski, P. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    Regression splines and fast Fourier transform (FFT) methods were used for smoothing the X-ray spectra obtained from the proportional counters. The programs for computation and optimization of the smoothed spectra were written in MATLAB languages. It was shown, that application of the smoothed spectra in the multivariate calibration can result in a considerable reduction of measurement errors. (author). 8 refs, 9 figs.

  19. X-ray spectra of Hercules X-1. 1: Iron line fluorescence from a subrelativistic shell

    Science.gov (United States)

    Pravdo, S. H.; Becker, R. H.; Boldt, E. A.; Holt, S. S.; Serlemitsos, P. J.; Swank, J. H.

    1977-01-01

    The X-ray spectrum of Hercules X-1 was observed in the energy range 2-24 keV from August 29 to September 3, 1975. A broad iron line feature is observed in the normal high state spectrum. The line equivalent width is given along with its full-width-half-maximum energy. Iron line fluorescence from an opaque, cool shell of material at the Alfven surface provides the necessary luminosity in this feature. The line energy width can be due to Doppler broadening if the shell is forced to corotate with the pulsar at a radius 800 million cm. Implications of this model regarding physical conditions near Her X-1 are discussed.

  20. A hydrodynamical model of Kepler's supernova remnant constrained by x-ray spectra

    International Nuclear Information System (INIS)

    Ballet, J.; Arnaud, M.; Rothinfluo, R.; Chieze, J.P.; Magne, B.

    1988-01-01

    The remnant of the historical supernova observed by Kepler in 1604 was recently observed in x-rays by the EXOSAT satellite up to 10 keV. A strong Fe K emission line around 6.5 keV is readily apparent in the spectrum. From an analysis of the light curve of the SN, reconstructed from historical descriptions, a previous study proposed to classify it as type I. Standard models of SN I based on carbon deflagration of white dwarf predict the synthesis of about 0.5 M circle of iron in the ejecta. Observing the iron line is a crucial check for such models. It has been argued that the light curve of Sn II-L is very similar to that of SN I and that the original observations are compatible with either type. In view of this uncertainty the authors have run a hydrodynamics-ionization code for both SN II and SN I remnants

  1. Soft x-ray absorption and emission spectra and the electronic structure of some exotic materials

    International Nuclear Information System (INIS)

    Ederer, D.L.; Canfield, L.R.; Callcott, T.A.; Tsang, K.L.; Zhang, C.H.; Arakawa, E.T.

    1988-01-01

    The technique of soft x-ray fluorescence spectroscopy (SXE) is complimentary to that of photoemission spectroscopy (PES). SXE probes the local partial density of states (PDOS), selects dipole allowed symmetries, and is not necessarily surface sensitive. PES on the other hand, averages over the DOS and can be used to measure the dispersion of the energy bands. PES is also very surface sensitive. We present measurements on the high T/sub c/ superconductors, the quasicrystalline phase of AlMn, and the LiAl intermetallic alloy. These measurements provide insight for theoretical modeling. In the case of the high T/sub c/ compound and the intermetallic compound the measurements are in good agreement with the theory. However, for the quasicrystals the measurements provide new insights to challenge theory. 13 refs., 3 figs

  2. L23 soft-x-ray emission and absorption spectra of Na

    International Nuclear Information System (INIS)

    Callcott, T.A.; Arakawa, E.T.; Ederer, D.L.

    1978-01-01

    The L 23 soft-x-ray emission (SXE) and soft-x-ray absorption (SXA) edges have been measured. The SXE edges were measured at temperatures between 85 and 380 K, and analyzed to obtain edge positions and widths. The widths increased from GAMMA/sub SXE/ = 100 meV at 85 K to 150 meV at 320 K and to 180 meV above the melting point at 380 K. Both SXE and SXA edges were measured at 100 K with the same spectrometer, and the data were analyzed to obtain values of the edge widths (GAMMA/sub SXE/ = 100 meV and GAMMA/sub SXA/ = 64 meV), of the many-body peaking parameter (α/sub SXE/ = 0.15 and α/sub SXA/ = 0.24), of the gap between the edges (E/sub g/ = 74 meV), and of the excess width of the emission edge [(ΔGAMMA) 2 = GAMMA 2 /sub SXE/ - GAMMA 2 /sub SXA/ = 5900 (meV) 2 ]. The values of E/sub g/ and (ΔGAMMA) 2 were used in the partial-lattice-relaxation theory of Almbladh to obtain a value of the core-hole lifetime broadening (GAMMA/sub 2p/ = 10 meV). We conclude that structure in the transition density of states, many-body effects, and lattice relaxation all have important effects on the edge structure, and suggest that rounding of the SXE edge by partial relaxation accounts for the smaller peaking parameter obtained from the SXE data as compared to the SXA data

  3. An algorithm for removing charging effects from X-ray photoelectron spectra of nanoscaled non-conductive materials

    Energy Technology Data Exchange (ETDEWEB)

    Gulyaev, R.V., E-mail: gulyaev@catalysis.ru [Boreskov Institute of Catalysis SB RAS, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Novosibirsk 630090 (Russian Federation); Koscheev, S.V. [Boreskov Institute of Catalysis SB RAS, Novosibirsk 630090 (Russian Federation); Malykhin, S.E. [Boreskov Institute of Catalysis SB RAS, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Novosibirsk 630090 (Russian Federation)

    2015-07-15

    Graphical abstract: - Highlights: • Algorithm for restoration of XP-spectra distorted by surface charging was developed. • Pd3d spectra of Pd/SnO{sub 2}, Pd/CeO{sub 2}–SnO{sub 2} catalysts were successfully restored. • Algorithm performance is comparable with “hardware” charging neutralization technique. - Abstract: Inhomogeneous surface charging could lead to a distortion of X-ray photoelectron (XP) spectra, which complicates the spectra analysis and sometimes results in an incorrect interpretation of elements chemical states of the sample. The charging effects might be especially strong in the case of XPS application for the characterization of heterogeneous catalysts, which are usually based on the dielectric or semiconductor materials with complex morphology. In this paper, we propose an algorithm to restore XP spectra when distortion is caused by inhomogeneous and/or non-constant surface charging effects. A photoelectron line of a reference element can be used to eliminate the distortions from experimental spectra of other elements by an iterative deconvolution procedure. The successful application of the algorithm for the restoration of a Pd3d line shape using a reference Sn3d{sub 5/2} line was demonstrated for the Pd/SnO{sub 2} and Pd/CeO{sub 2}–SnO{sub 2} catalysts.

  4. Calculation of X-ray photoelectron spectra with the use of the normalized elimination of the small component method

    International Nuclear Information System (INIS)

    Klooster, Rob; Broer, Ria; Filatov, Michael

    2012-01-01

    Graphical abstract: A newly developed method for the calculation of X-ray photoelectron spectra (XPS) is applied to study the 4p and 5p XPS of ytterbium phosphide YbP. The results of the calculations suggest an alternative interpretation of the satellite peaks in the 4p XPS of YbP. Highlights: ► A new method based on NESC for calculating XPS spectra has been developed. ►Results for U 5+ show excellent agreement compared to fully relativistic methods. ►Large systems can be treated at the computational cost of non-relativistic methods. ►Calculations on YbP show the effects of the crystal environment on the spectra. ►Alternative interpretation of the satellite peaks in the 4p XPS of YbP. - Abstract: A method for the calculation of X-ray photoelectron spectra (XPS) based on the use of the normalized elimination of the small component (NESC) formalism combined with the restricted active space state interaction (RASSI) approach with atomic mean field integrals (AMFI) is developed. Benchmark calculations carried out for the 4f XPS of U 5+ show that the NESC/RASSI/AMFI method is capable of reproducing the results of the full 4-component relativistic calculations with excellent accuracy. The NESC/RASSI/AMFI method is applied to study the 4p and 5p XPS of ytterbium phosphide YbP. The results of the calculations suggest an alternative interpretation of the satellite peaks in the 4p XPS of YbP.

  5. Element sensitive reconstruction of nanostructured surfaces with finite elements and grazing incidence soft X-ray fluorescence.

    Science.gov (United States)

    Soltwisch, Victor; Hönicke, Philipp; Kayser, Yves; Eilbracht, Janis; Probst, Jürgen; Scholze, Frank; Beckhoff, Burkhard

    2018-03-29

    The geometry of a Si3N4 lamellar grating was investigated experimentally with reference-free grazing-incidence X-ray fluorescence analysis. While simple layered systems are usually treated with the matrix formalism to determine the X-ray standing-wave field, this approach fails for laterally structured surfaces. Maxwell solvers based on finite elements are often used to model electrical field strengths for any 2D or 3D structures in the optical spectral range. We show that this approach can also be applied in the field of X-rays. The electrical field distribution obtained with the Maxwell solver can subsequently be used to calculate the fluorescence intensities in full analogy to the X-ray standing-wave field obtained by the matrix formalism. Only the effective 1D integration for the layer system has to be replaced by a 2D integration of the finite elements, taking into account the local excitation conditions. We will show that this approach is capable of reconstructing the geometric line shape of a structured surface with high elemental sensitivity. This combination of GIXRF and finite-element simulations paves the way for a versatile characterization of nanoscale-structured surfaces.

  6. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra

    OpenAIRE

    Takegami, Kazuki ; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi ; Maehata, Itsumi ; Kanazawa, Yuki ; Okazaki, Tohru ; Hashizume, Takuya ; Kobayashi, Ikuo 

    2016-01-01

    Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1–20 cm), and a CdTe X...

  7. Empirical relationship between x-ray photoemission spectra and electrical conductivity in a colossal magnetoresistive manganite La_{1-x}Sr_{x}MnO_{3}

    OpenAIRE

    Hishida, T.; Ohbayashi, K.; Kobata, M.; Ikenaga, E.; Sugiyama, T.; Kobayashi, K.; Okawa, M.; Saitoh, T.

    2013-01-01

    By using laboratory x-ray photoemission spectroscopy (XPS) and hard x-ray photoemission spectroscopy (HX-PES) at a synchrotron facility, we report an empirical semi-quantitative relationship between the valence/core-level x-ray photoemission spectral weight and electrical conductivity in La_{1-x}Sr_{x}MnO_{3} as a function of x. In the Mn 2p_{3/2} HX-PES spectra, we observed the shoulder structure due to the Mn^{3+} well-screened state. However, the intensity at x=0.8 was too small to explain...

  8. 1SXPS: A DEEP SWIFT X-RAY TELESCOPE POINT SOURCE CATALOG WITH LIGHT CURVES AND SPECTRA

    International Nuclear Information System (INIS)

    Evans, P. A.; Osborne, J. P.; Beardmore, A. P.; Page, K. L.; Willingale, R.; Mountford, C. J.; Pagani, C.; Burrows, D. N.; Kennea, J. A.; Perri, M.; Tagliaferri, G.; Gehrels, N.

    2014-01-01

    We present the 1SXPS (Swift-XRT point source) catalog of 151,524 X-ray point sources detected by the Swift-XRT in 8 yr of operation. The catalog covers 1905 deg 2 distributed approximately uniformly on the sky. We analyze the data in two ways. First we consider all observations individually, for which we have a typical sensitivity of ∼3 × 10 –13  erg cm –2  s –1 (0.3-10 keV). Then we co-add all data covering the same location on the sky: these images have a typical sensitivity of ∼9 × 10 –14  erg cm –2  s –1 (0.3-10 keV). Our sky coverage is nearly 2.5 times that of 3XMM-DR4, although the catalog is a factor of ∼1.5 less sensitive. The median position error is 5.''5 (90% confidence), including systematics. Our source detection method improves on that used in previous X-ray Telescope (XRT) catalogs and we report >68, 000 new X-ray sources. The goals and observing strategy of the Swift satellite allow us to probe source variability on multiple timescales, and we find ∼30, 000 variable objects in our catalog. For every source we give positions, fluxes, time series (in four energy bands and two hardness ratios), estimates of the spectral properties, spectra and spectral fits for the brightest sources, and variability probabilities in multiple energy bands and timescales

  9. Local moments and electronic correlations in Fe-based Heusler alloys: Kα x-ray emission spectra measurements

    Energy Technology Data Exchange (ETDEWEB)

    Svyazhin, Artem, E-mail: svyazhin@imp.uran.ru [M.N. Mikheev Institute of Metal Physics, Russian Academy of Sciences – Ural Division, 620990 Yekaterinburg (Russian Federation); Kurmaev, Ernst; Shreder, Elena; Shamin, Sergey [M.N. Mikheev Institute of Metal Physics, Russian Academy of Sciences – Ural Division, 620990 Yekaterinburg (Russian Federation); Sahle, Christoph J. [ESRF – The European Synchrotron, CS40220, 38043 Grenoble Cedex 9 (France)

    2016-09-15

    Heusler alloys are a property-rich class of materials, intensively investigated today from both theoretical and real-world application points of view. In this paper, we attempt to shed light on the role of electronic correlations in the Fe{sub 2}MeAl group (where Me represents all 3d elements from Ti to Ni) of Heusler alloys. For this purpose, we have investigated the local moments of iron by means of the x-ray emission spectroscopy technique. To obtain numerical values of local moments, the Kα-FWHM method has been employed for the first time. In every compound of the group, the presence of a local moment on the Fe atom was detected. As has been revealed, the values of these moments are temperature-independent, pointing to an insufficiency of a pure itinerant approach to magnetism in these alloys. We also comprehensively compare the usage of Kβ main lines and Kα spectra as tools for the probing of local moments and point out the significant advantages of the latter. - Highlights: • Local spin moments of iron in Fe{sub 2}MeAl (Me = Ti … Ni) Heusler alloys were investigated by means of x-ray emission spectroscopy. • Independence of the local moments from temperature confirms their localized nature. • A local moment value of iron in Fe{sub 2}MeAl raises with the atomic number of element Me. • The applicability of the Kα x-ray emission line for extracting local moment values of 3d elements was established.

  10. Local moments and electronic correlations in Fe-based Heusler alloys: Kα x-ray emission spectra measurements

    International Nuclear Information System (INIS)

    Svyazhin, Artem; Kurmaev, Ernst; Shreder, Elena; Shamin, Sergey; Sahle, Christoph J.

    2016-01-01

    Heusler alloys are a property-rich class of materials, intensively investigated today from both theoretical and real-world application points of view. In this paper, we attempt to shed light on the role of electronic correlations in the Fe 2 MeAl group (where Me represents all 3d elements from Ti to Ni) of Heusler alloys. For this purpose, we have investigated the local moments of iron by means of the x-ray emission spectroscopy technique. To obtain numerical values of local moments, the Kα-FWHM method has been employed for the first time. In every compound of the group, the presence of a local moment on the Fe atom was detected. As has been revealed, the values of these moments are temperature-independent, pointing to an insufficiency of a pure itinerant approach to magnetism in these alloys. We also comprehensively compare the usage of Kβ main lines and Kα spectra as tools for the probing of local moments and point out the significant advantages of the latter. - Highlights: • Local spin moments of iron in Fe 2 MeAl (Me = Ti … Ni) Heusler alloys were investigated by means of x-ray emission spectroscopy. • Independence of the local moments from temperature confirms their localized nature. • A local moment value of iron in Fe 2 MeAl raises with the atomic number of element Me. • The applicability of the Kα x-ray emission line for extracting local moment values of 3d elements was established.

  11. Grazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces

    International Nuclear Information System (INIS)

    Meirer, F.; Streli, C.; Wobrauschek, P.; Zoeger, N.; Pepponi, G.

    2009-01-01

    In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence (GI) setup to compare the performance of both geometries. Furthermore, the investigations were accomplished to gain a better understanding of the so called self-absorption effect, which was observed and investigated in previous studies using a GI geometry. It was suggested that a normal incidence-grazing-exit geometry would not suffer from self-absorption effects in x-ray absorption fine structure (XAFS) analysis due to the minimized path length of the incident beam through the sample. The results proved this assumption and in turn confirmed the occurrence of the self-absorption effect for GI geometry. Due to its lower sensitivity it is difficult to apply the GE geometry to XAFS analysis of trace amounts (few nanograms) of samples but the technique is well suited for the analysis of small amounts of concentrated samples

  12. Development of grazing incidence multilayer mirrors for hard X-ray focusing telescopes

    DEFF Research Database (Denmark)

    Mao, Peter H.; Harrison, Fiona A.; Platonov, Yuriy Y.

    1997-01-01

    We are developing depth-graded, multilayer-coated mirrors for astrophysical hard X-ray focusing telescopes. In this paper, we discuss the primary technical challenges associated with the multilayer coatings, and report on progress to date. We have sputtered constant d-spacing and depth-graded W/S...

  13. Medium-sized grazing incidence high-energy X-ray telescopes employing continuously graded multilayers

    DEFF Research Database (Denmark)

    Joensen, K. D.; Christensen, Finn Erland; Schnopper, H. W.

    1993-01-01

    The authors present a concept of continuously graded multilayer structures for medium-sized X-ray telescopes which is based on several material combinations. They show that the theoretical reflectivity characteristics of these structures make them very advantageous when applied to high energy X-r...

  14. Standing-wave effects in grazing-incidence x-ray diffraction from polycrystalline multilayers

    Czech Academy of Sciences Publication Activity Database

    Krčmář, J.; Holý, V.; Horák, L.; Metzger, T. H.; Sobota, Jaroslav

    2008-01-01

    Roč. 103, č. 3 (2008), 033504:1-7 ISSN 0021-8979 Institutional research plan: CEZ:AV0Z20650511 Keywords : acoustic wave interference * carbon * crystallites * interface structure * nickel * optical multilayers * superlattices * X-ray diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.201, year: 2008

  15. Quantitative determination of the lateral density and intermolecular correlation between proteins anchored on the membrane surfaces using grazing incidence small-angle X-ray scattering and grazing incidence X-ray fluorescence.

    Science.gov (United States)

    Abuillan, Wasim; Vorobiev, Alexei; Hartel, Andreas; Jones, Nicola G; Engstler, Markus; Tanaka, Motomu

    2012-11-28

    As a physical model of the surface of cells coated with densely packed, non-crystalline proteins coupled to lipid anchors, we functionalized the surface of phospholipid membranes by coupling of neutravidin to biotinylated lipid anchors. After the characterization of fine structures perpendicular to the plane of membrane using specular X-ray reflectivity, the same membrane was characterized by grazing incidence small angle X-ray scattering (GISAXS). Within the framework of distorted wave Born approximation and two-dimensional Percus-Yevick function, we can analyze the form and structure factors of the non-crystalline, membrane-anchored proteins for the first time. As a new experimental technique to quantify the surface density of proteins on the membrane surface, we utilized grazing incidence X-ray fluorescence (GIXF). Here, the mean intermolecular distance between proteins from the sulfur peak intensities can be calculated by applying Abelé's matrix formalism. The characteristic correlation distance between non-crystalline neutravidin obtained by the GISAXS analysis agrees well with the intermolecular distance calculated by GIXF, suggesting a large potential of the combination of GISAXS and GIXF in probing the lateral density and correlation of non-crystalline proteins displayed on the membrane surface.

  16. Quantum-classical calculations of X-ray photoelectron spectra of polymers—Polymethyl methacrylate revisited

    Science.gov (United States)

    Löytynoja, T.; Harczuk, I.; Jänkälä, K.; Vahtras, O.; Ågren, H.

    2017-03-01

    In this work, we apply quantum mechanics/molecular mechanics (QM/MM) approach to predict core-electron binding energies and chemical shifts of polymers, obtainable via X-ray photoelectron spectroscopy (XPS), using polymethyl methacrylate as a demonstration example. The results indicate that standard parametrizations of the quantum part (basis sets, level of correlation) and the molecular mechanics parts (decomposed charges, polarizabilities, and capping technique) are sufficient for the QM/MM model to be predictive for XPS of polymers. It is found that the polymer environment produces contributions to the XPS binding energies that are close to monotonous with the number of monomer units, totally amounting to approximately an eV decrease in binding energies. In most of the cases, the order of the shifts is maintained, and even the relative size of the differential shifts is largely preserved. The coupling of the internal core-hole relaxation to the polymer environment is found to be weak in each case, amounting only to one or two tenths of an eV. The main polymeric effect is actually well estimated already at the frozen orbital level of theory, which in turn implies a substantial computational simplification. These conclusions are best represented by the cases where the ionized monomer and its immediate surrounding are treated quantum mechanically. If the QM region includes only a single monomer, a couple of anomalies are spotted, which are referred to the QM/MM interface itself and to the neglect of a possible charge transfer.

  17. Quantum-classical calculations of X-ray photoelectron spectra of polymers-Polymethyl methacrylate revisited.

    Science.gov (United States)

    Löytynoja, T; Harczuk, I; Jänkälä, K; Vahtras, O; Ågren, H

    2017-03-28

    In this work, we apply quantum mechanics/molecular mechanics (QM/MM) approach to predict core-electron binding energies and chemical shifts of polymers, obtainable via X-ray photoelectron spectroscopy(XPS), using polymethyl methacrylate as a demonstration example. The results indicate that standard parametrizations of the quantum part (basis sets, level of correlation) and the molecular mechanics parts (decomposed charges, polarizabilities, and capping technique) are sufficient for the QM/MM model to be predictive for XPS of polymers. It is found that the polymer environment produces contributions to the XPS binding energies that are close to monotonous with the number of monomer units, totally amounting to approximately an eV decrease in binding energies. In most of the cases, the order of the shifts is maintained, and even the relative size of the differential shifts is largely preserved. The coupling of the internal core-hole relaxation to the polymer environment is found to be weak in each case, amounting only to one or two tenths of an eV. The main polymeric effect is actually well estimated already at the frozen orbital level of theory, which in turn implies a substantial computational simplification. These conclusions are best represented by the cases where the ionized monomer and its immediate surrounding are treated quantum mechanically. If the QM region includes only a single monomer, a couple of anomalies are spotted, which are referred to the QM/MM interface itself and to the neglect of a possible charge transfer.

  18. Spatially resolved x-ray laser spectra and demonstration of gain in nickel-like systems

    Energy Technology Data Exchange (ETDEWEB)

    Whelan, D.A.; Keane, C.J.; MacGowan, B.J.; Matthews, D.L.; Trebes, J.E.; Eckart, M.J.

    1987-09-25

    A recent series of experiments have provided spatially resolved near field images of several candidate x-ray lasing transition in neon-like, nickel-like, and hydrogen-like ions from laser-produced plasmas. From these time-gated, spatially, and spectrally resolved measurements the source size for the J = 0 - 1 and the J = 2 - 1 transitions in Ne-like selenium have been determined. Source regions as small as 50 ..mu..m have been observed on transitions with gain-length products >9. In addition, we have obtained the first experimental evidence for the amplification of spontaneous emission in the nickel-like ions of europium and ytterbium. Gains of order 1 cm/sup -1/ and gain-length products of up to 3.8 are observed on the J = 0 - 1, 4d-4p transitions in Eu + 35 at 65.26 and 71.00 A. Analogous transitions in Yb = +42 have been identified and some evidence for ASE has been observed. 7 refs., 11 figs.

  19. XMM-Newton Survey of Local O VII Absorption Lines in the Spectra of Galactic X-Ray Sources

    Science.gov (United States)

    Luo, Yang; Fang, Taotao; Ma, Renyi

    2018-04-01

    The detection of highly ionized metal absorption lines in the X-ray spectra of the Galactic X-ray binaries (XRBs) implies the distribution of hot gas along the sightline toward the background sources. However, the origin of this hot gas is still unclear: it can arise in the hot interstellar medium (ISM), or is intrinsic to the XRBs. In this paper, we present an XMM-Newton survey of the O VII absorption lines in the spectra of Galactic XRBs. A total of 33 XRBs were selected, with 29 low-mass XRBs and 4 high-mass XRBs. At a more than 3σ threshold, O VII absorption line was detected in 16 targets, among which 4 were newly discovered in this work. The average line equivalent width is centered around ∼20 mÅ. Additionally, we do not find strong correlations between the O VII EWs and the Galactic neutral absorption N H, the Galactic coordinates, or the distance of background targets. Such non-correlation may suggest contamination of the circumstellar material, or a lack of constraints on the line Doppler-b parameter. We also find that regardless of the direction of the XRBs, the O VII absorption lines are always detected when the flux of the background XRBs reaches a certain level, suggesting a uniform distribution of this hot gas. We estimate a ratio of 0.004–0.4 between the hot and neutral phases of the ISM. This is the second paper in the series following Fang et al. (2015), in which we focused on the local O VII absorption lines detected in the background AGN spectra. Detailed modeling of the hot ISM distribution will be investigated in a future paper.

  20. ULX spectra revisited: Are accreting, highly magnetized neutron stars the engines of ultraluminous X-ray sources?

    Science.gov (United States)

    Koliopanos, F.; Vasilopoulos, G.; Bachetti, M.; Godet, O.; Webb, N.; Barret, D.

    2017-10-01

    In light of recent discoveries of pulsating ULXs and recently introduced models placing neutron stars as the central engines of ULXs, we revisit the spectra of seventeen ULXs, in search of indications that favor this hypothesis. To this end we examined the spectra from XMM-Newton observations of all seventeen sources in our sample. For six sources, these were complimented with spectra from public NuSTAR observations. We demonstrate that the notable ({>}6 keV) spectral curvature observed in most ULXs, is most likely due to thermal emission, with T{>} 1keV. More importantly, we find that a double thermal model (comprised of a 'cool' and 'hot' thermal component) - often associated with emission from neutron star X-ray binaries - describes all ULX spectra in our list. We propose that the dual thermal spectrum is the result of accretion onto highly magnetized NSs, as predicted in recent theoretical models (Mushtukov et al. 2017). We further argue that this finding offers an additional and compelling argument in favor of neutron stars as prime candidates for powering ULXs, as has been recently suggested (King & Lasota 2016; King et al. 2017). In my talk I will discuss the implications of our interpretation along with its merits and shortcomings.

  1. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager.

    Science.gov (United States)

    Nagayama, T; Mancini, R C; Mayes, D; Tommasini, R; Florido, R

    2015-11-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ∼6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ∼10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

  2. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

    Science.gov (United States)

    Nagayama, T.; Mancini, R. C.; Mayes, D.; Tommasini, R.; Florido, R.

    2015-11-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ˜6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ˜10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

  3. Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

    International Nuclear Information System (INIS)

    Nagayama, T.; Mancini, R. C.; Mayes, D.; Tommasini, R.; Florido, R.

    2015-01-01

    Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. Here, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ∼6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ∼10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. It is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application

  4. Interface characterization of B4C-based multilayers by X-ray grazing-incidence reflectivity and diffuse scattering.

    Science.gov (United States)

    Jiang, Hui; Wang, Zhanshan; Zhu, Jingtao

    2013-05-01

    B4C-based multilayers have important applications for soft to hard X-rays. In this paper, X-ray grazing-incidence reflectivity and diffuse scattering, combining various analysis methods, were used to characterize the structure of B4C-based multilayers including layer thickness, density, interfacial roughness, interdiffusion, correlation length, etc. Quantitative results for W/B4C, Mo/B4C and La/B4C multilayers were compared. W/B4C multilayers show the sharpest interfaces and most stable structures. The roughness replications of La/B4C and Mo/B4C multilayers are not strong, and oxidations and structure expansions are found in the aging process. This work provides guidance for future fabrication and characterization of B4C-based multilayers.

  5. Novel micro-reactor flow cell for investigation of model catalysts using in situ grazing-incidence X-ray scattering

    DEFF Research Database (Denmark)

    Kehres, Jan; Pedersen, Thomas; Masini, Federico

    2016-01-01

    -incidence small-angle X-ray scattering (GISAXS) in transmission through 10 µm-thick entrance and exit windows by using micro-focused beams. An additional thinning of the Pyrex glass reactor lid allows simultaneous acquisition of the grazing-incidence wide-angle X-ray scattering (GIWAXS). In situ experiments......The design, fabrication and performance of a novel and highly sensitive micro-reactor device for performing in situ grazing-incidence X-ray scattering experiments of model catalyst systems is presented. The design of the reaction chamber, etched in silicon on insulator (SIO), permits grazing...

  6. On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

    Science.gov (United States)

    Champey, Patrick; Winebarger, Amy; Kobayashi, Ken; Savage, Sabrina; Cirtain, Jonathan; Cheimets, Peter; Hertz, Edward; Golub, Leon; Ramsey, Brian; McCracken, Jeff

    2016-01-01

    The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

  7. Soft X-Ray Spectra from High Current Nitrogen Z-Pinch Discharge

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Vrbová, M.; Nevrkla, M.; Jančárek, A.

    2016-01-01

    Roč. 3, č. 1 (2016), s. 48 ISSN 2336-2626. [SPPT 2016 - 27th Symposium on Plasma Physics and Technology/27./. Prague, 20.06.2016-23.06.2016] Institutional support: RVO:61389021 Keywords : Capillary discharge * recombination pumping * pinch dynamics * evolution of spectra emission * computer modelling Subject RIV: BH - Optics, Masers, Lasers www.plasmaconference.cz

  8. Energy-dependent dead-time correction in digital pulse processors applied to silicon drift detector's X-ray spectra.

    Science.gov (United States)

    Barros, Suelen F; Vanin, Vito R; Malafronte, Alexandre A; Maidana, Nora L; Martins, Marcos N

    2018-03-01

    Dead-time effects in X-ray spectra taken with a digital pulse processor and a silicon drift detector were investigated when the number of events at the low-energy end of the spectrum was more than half of the total, at counting rates up to 56 kHz. It was found that dead-time losses in the spectra are energy dependent and an analytical correction for this effect, which takes into account pulse pile-up, is proposed. This and the usual models have been applied to experimental measurements, evaluating the dead-time fraction either from the calculations or using the value given by the detector acquisition system. The energy-dependent dead-time model proposed fits accurately the experimental energy spectra in the range of counting rates explored in this work. A selection chart of the simplest mathematical model able to correct the pulse-height distribution according to counting rate and energy spectrum characteristics is included.

  9. Conformation and orientation effects in the x-ray photoelectron spectra of organic polymers

    International Nuclear Information System (INIS)

    Beamson, G.

    2001-01-01

    Conformation and orientation effects in the XPS spectra of organic polymers are small but can be observed with modem high performance equipment. This paper discusses some of the experimental factors that should be considered when attempting to detect such effects, and describes several recent studies which illustrate the subtle phenomena that can now be observed. Conformation effects, revealed by melting semicrystalline polymer samples in the analysis chamber of an XPS spectrometer, are reported for the valence band and C 1s spectra of nylon 12 and poly(ethylene adipate), and for the valence band spectrum of poly(ethylene succinate). For nylon 12 the changes in the C 2s region of the valence band spectrum are interpreted in terms of disordering of the planar zig-zag conformation of the (CH 2 ) 11 segments of the polymer chain. Pendant group surface orientation effects, detected by angle resolved XPS (with emission angles as low as 5 deg. relative to the sample surface), are reported for poly(2-chloroethyl methacrylate) (PCEMA), poly(lauryl methacrylate) (PLMA) and poly(2-hydroxyethyl methacrylate) (PHEMA). For PCEMA and PLMA the uppermost surfaces are enriched with -CH 2 CH 2 Cl and -(CH 2 ) 11 CH 3 pendant groups respectively, whereas for PHEMA the data suggest relatively few -CH 2 CH 2 OH pendant groups at the surface. The C 1s and Cl 2p spectra of PCEMA reveal surface core level binding energy shifts of - +0.2 eV, and the Cl L 23 M 23 M 23 spectrum a surface Auger kinetic energy shift of ∼ -0.6. The C 1s spectra of PLMA and PHEMA also reveal surface core level shifts and for PLMA this is interpreted in terms of a disordered and open arrangement of the -(CH 2 ) 11 CH 3 pendant groups at the polymer surface. (author)

  10. Evaluation of transmitted spectra of megavoltage X rays through concrete using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Cordeiro, Thaiana de Paula Vieira; Silva, Ademir Xavier da

    2010-01-01

    With the improvement of technology in radiotherapic centers, medical linear accelerators are largely replacing Cobalt-60 teletherapy units. In most of the cases, the same room that, before, was used to place a 60 Co teletherapy unit is reused to install, in replacement, a linear accelerator. When the room physical space can not be changed, high - density concrete is employed to provide shielding against the primary, scatter and leakage radiation. This work presents a study based on Monte Carlo simulations of transmission of some clinical photon spectra (of 10, 15 and 25 MV accelerators) through concrete of two different densities. Concrete walls of thickness 1.0, 1.5 and 2.0 m were irradiated with 30 cm x 30 cm primary beam spectra. The results show that the thickness of the barrier decreases up to approximately 35%, when barite (high - density concrete) is used instead of ordinary concrete. The average energies of primary and transmitted beam spectra were also calculated. (author)

  11. Accounting for nanometer-thick adventitious carbon contamination in X-ray absorption spectra of carbon-based materials.

    Science.gov (United States)

    Mangolini, Filippo; McClimon, J Brandon; Rose, Franck; Carpick, Robert W

    2014-12-16

    Near-edge X-ray absorption fine structure (NEXAFS) spectroscopy is a powerful technique for characterizing the composition and bonding state of nanoscale materials and the top few nanometers of bulk and thin film specimens. When coupled with imaging methods like photoemission electron microscopy, it enables chemical imaging of materials with nanometer-scale lateral spatial resolution. However, analysis of NEXAFS spectra is often performed under the assumption of structural and compositional homogeneity within the nanometer-scale depth probed by this technique. This assumption can introduce large errors when analyzing the vast majority of solid surfaces due to the presence of complex surface and near-surface structures such as oxides and contamination layers. An analytical methodology is presented for removing the contribution of these nanoscale overlayers from NEXAFS spectra of two-layered systems to provide a corrected photoabsorption spectrum of the substrate. This method relies on the subtraction of the NEXAFS spectrum of the overlayer adsorbed on a reference surface from the spectrum of the two-layer system under investigation, where the thickness of the overlayer is independently determined by X-ray photoelectron spectroscopy (XPS). This approach is applied to NEXAFS data acquired for one of the most challenging cases: air-exposed hard carbon-based materials with adventitious carbon contamination from ambient exposure. The contribution of the adventitious carbon was removed from the as-acquired spectra of ultrananocrystalline diamond (UNCD) and hydrogenated amorphous carbon (a-C:H) to determine the intrinsic photoabsorption NEXAFS spectra of these materials. The method alters the calculated fraction of sp(2)-hybridized carbon from 5 to 20% and reveals that the adventitious contamination can be described as a layer containing carbon and oxygen ([O]/[C] = 0.11 ± 0.02) with a thickness of 0.6 ± 0.2 nm and a fraction of sp(2)-bonded carbon of 0.19 ± 0.03. This

  12. Use of X-Ray Absorption Spectra as a ``Fingerprint'' of the Local Environment in Complex Chalcogenides

    Science.gov (United States)

    Branci, C.; Womes, M.; Lippens, P. E.; Olivier-Fourcade, J.; Jumas, J. C.

    2000-03-01

    The local environment of tin, titanium, iron, and sulfur in spinel compounds Cu2FeSn3S8 and Cu2FeTi3S8 was studied by X-ray absorption spectroscopy (XAS) at the titanium, iron, sulfur K edges, and the tin LI-edge. As detailed calculations of the electronic structure of these compounds are difficult to carry out due to the large number of atoms contained in the unit cell, the XAS spectra of the spinels are compared to those of relatively simple binary sulfides like SnS2, TiS2, and FeS. Indeed, the metal environments in these binary compounds are very similar to those in the spinels, and they can be considered good model compounds allowing the interpretation of electronic transitions observed in the spectra of quaternary phases. In the latter, the bottom of the conduction band is mainly formed by Sn 5s-S 3p, Sn 5p-S 3p antibonding states for the tin-based compounds and by Ti 3dt2g-S 3p, Ti 3deg-S 3p antibonding states for the titanium-based compounds. It it shown that the local environment of iron atoms remains unchanged when substituting tin with titanium atoms, according to a topotactic substitution.

  13. Anomalous grazing incidence small-angle x-ray scattering studies of Pt nanoparticles formed by cluster deposition

    International Nuclear Information System (INIS)

    Lee, B.; Seifert, S.; Riley, S.J.; Tikhonov, G.Y.; Tomczyk, N.A.; Vajda, S.; Winans, R.E.

    2005-01-01

    The size evolution of platinum nanoparticles formed on a SiO2/Si(111) substrate as a function of the level of surface coverage with deposited clusters has been investigated. The anisotropic shapes of sub-nanometer-size nanoparticles are changed to isotropic on the amorphous substrate as their sizes increased. Using anomalous grazing incidence small-angle x-ray scattering (AGISAXS), the scattering from nanoparticles on the surface of a substrate is well separated from that of surface roughness and fluorescence. We show that AGISAXS is a very effective method to subtract the background and can provide unbiased information about particle sizes of less than 1 nm.

  14. Grazing incidence X-ray fluorescence analysis of buried interfaces in periodically structured crystalline silicon thin-film solar cells

    International Nuclear Information System (INIS)

    Eisenhauer, David; Preidel, Veit; Becker, Christiane; Pollakowski, Beatrix; Beckhoff, Burkhard; Baumann, Jonas; Kanngiesser, Birgit; Amkreutz, Daniel; Rech, Bernd; Back, Franziska; Rudigier-Voigt, Eveline

    2015-01-01

    We present grazing incidence X-ray fluorescence (GIXRF) experiments on 3D periodically textured interfaces of liquid phase crystallized silicon thin-film solar cells on glass. The influence of functional layers (SiO x or SiO x /SiC x ) - placed between glass substrate and silicon during crystallization - on the final carbon and oxygen contaminations inside the silicon was analyzed. Baring of the buried structured silicon surface prior to GIXRF measurement was achieved by removal of the original nano-imprinted glass substrate by wet-chemical etching. A broad angle of incidence distribution was determined for the X-ray radiation impinging on this textured surface. Optical simulations were performed in order to estimate the incident radiation intensity on the structured surface profile considering total reflection and attenuation effects. The results indicate a much lower contamination level for SiO x compared to the SiO x /SiC x interlayers, and about 25% increased contamination when comparing structured with planar silicon layers, both correlating with the corresponding solar cell performances. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Measured and Monte Carlo simulated surface dose reduction for superficial X-rays incident on tissue with underlying air or bone.

    Science.gov (United States)

    Baines, John; Zawlodzka, Sylwia; Markwell, Tim; Chan, Millicent

    2018-02-01

    Measurement of surface dose reduction effects for superficial x-rays incident on tissue with underlying air or bone and comparison with Monte Carlo simulations of such effects. Further to investigate the correlation between surface dose reduction and changes in Compton backscatter spectra with tissue-bone separation. An Advanced Markus chamber with entrance window facing downstream on the surface of a solid water phantom was used to investigate changes in surface dose with an underlying air or bone interface located at various depths below the surface. Chamber readings were obtained for interface depths ranging from 1 to 100 mm using the 50 kV, 100 kV and 150 kV beams of an Xstrahl 150 x-ray unit, with field diameters (ϕ) = 2.5 cm and 5 cm. For each beam quality and field size the dose correction factor, DCF(t), namely the ratio of measured dose (t) to dose (t = 100 mm) was determined. Monte Carlo simulations of DCF(t) for air and bone interfaces in tissue are used to validate corresponding measured data. For a given beam and field size, the difference between simulated spectra with an air or bone interface at t = 3 mm was used to determine the Compton backscatter from bone at the surface. For air, DCF(t tube potentials corresponding factors, ϕ = 2.5 cm, for air(bone) are 0.94(0.96) and 0.92(0.99). Calculated DCF(t) based on Monte Carlo simulations are consistent with experimental observations to within 2%. Monte Carlo simulations of x-ray spectra demonstrate the presence of Compton backscatter from underlying bone in tissue. With bone at 3 mm depth calculated backscatter spectra at the tissue surface suggest that surface dose is influenced by the proximity of bone and that this effect depends on beam quality. This work demonstrates the feasibility of using an Advanced Markus chamber with entrance window facing downstream to investigate surface dose reduction with underlying air or bone in tissue. As the field size decreases and beam quality increases surface

  16. Aplanatic telescopes based on Schwarzschild optical configuration: from grazing incidence Wolter-like x-ray optics to Cherenkov two-mirror normal incidence telescopes

    Science.gov (United States)

    Sironi, Giorgia

    2017-09-01

    At the beginning of XX century Karl Schwarzschild defined a method to design large-field aplanatic telescopes based on the use of two aspheric mirrors. The approach was then refined by Couder (1926) who, in order to correct for the astigmatic aberration, introduced a curvature of the focal plane. By the way, the realization of normal-incidence telescopes implementing the Schwarzschild aplanatic configuration has been historically limited by the lack of technological solutions to manufacture and test aspheric mirrors. On the other hand, the Schwarzschild solution was recovered for the realization of coma-free X-ray grazing incidence optics. Wolter-like grazing incidence systems are indeed free of spherical aberration, but still suffer from coma and higher order aberrations degrading the imaging capability for off-axis sources. The application of the Schwarzschild's solution to X-ray optics allowed Wolter to define an optical system that exactly obeys the Abbe sine condition, eliminating coma completely. Therefore these systems are named Wolter-Schwarzschild telescopes and have been used to implement wide-field X-ray telescopes like the ROSAT WFC and the SOHO X-ray telescope. Starting from this approach, a new class of X-ray optical system was proposed by Burrows, Burg and Giacconi assuming polynomials numerically optimized to get a flat field of view response and applied by Conconi to the wide field x-ray telescope (WFXT) design. The Schwarzschild-Couder solution has been recently re-discovered for the application to normal-incidence Cherenkov telescopes, thanks to the suggestion by Vassiliev and collaborators. The Italian Institute for Astrophysics (INAF) realized the first Cherenkov telescope based on the polynomial variation of the Schwarzschild configuration (the so-called ASTRI telescope). Its optical qualification was successfully completed in 2016, demonstrating the suitability of the Schwarzschild-like configuration for the Cherenkov astronomy requirements

  17. On the importance of the magnetic dipole term T.sub.z./sub. in analyzing X-ray magnetic circular dichroism spectra of clusters

    Czech Academy of Sciences Publication Activity Database

    Šipr, Ondřej; Minár, J.; Ebert, H.

    2009-01-01

    Roč. 87, č. 6 (2009), 67007/1-67007/6 ISSN 0295-5075 R&D Projects: GA ČR GA202/08/0106 Institutional research plan: CEZ:AV0Z10100521 Keywords : x-ray absorption spectra * magnetic moments * nanostructures Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.893, year: 2009

  18. Glancing-incidence X-ray diffraction of Ag nanoparticles in gold lustre decoration of Italian Renaissance pottery

    International Nuclear Information System (INIS)

    Bontempi, E.; Colombi, P.; Depero, L.E.; Cartechini, L.; Presciutti, F.; Brunetti, B.G.; Sgamellotti, A.

    2006-01-01

    Lustre is known as one of the most significant decorative techniques of Medieval and Renaissance pottery in the Mediterranean basin, characterized by brilliant gold and red metallic reflections and iridescence effects. Previous studies by various techniques (SEM-EDS and TEM, UV-VIS, XRF, RBS and EXAFS) demonstrated that lustre consists of a heterogeneous metal-glass composite film, formed by Cu and Ag nanoparticles dispersed within the outer layer of a tin-opacified lead glaze. In the present work the investigation of an original gold lustre sample from Deruta has been carried out by means of glancing-incidence X-ray diffraction techniques (GIXRD). The study was aimed at providing information on structure and depth distribution of Ag nanoparticles. Exploiting the capability of controlling X-ray penetration in the glaze by changing the incidence angle, we used GIXRD measurements to estimate non-destructively thickness and depth of silver particles present in the first layers of the glaze. (orig.)

  19. Advanced laser-backlit grazing-incidence x-ray imaging systems for inertial confinement fusion research. II. Tolerance analysis

    International Nuclear Information System (INIS)

    Bennett, Guy R.; Folta, James A.

    2001-01-01

    Two example ultrahigh-spatial resolution laser-backlit grazing-incidence x-ray microscope designs for inertial confinement fusion (ICF) research have been described [Appl. Opt. 40, 4570 (2001)]. Here details of fabrication, assembly, and optical surface errors that are characteristic of present state-of-the-art superpolished multilayer-coated spherical mirrors are given. They indicate that good image qualities can be expected; in particular, <0.5-μm spatial resolution at very high x-ray energies (up to 25 keV) appears to be feasible. Existing ICF imaging diagnostics approach ∼2 μm spatial at low (<2 keV) energy. The improvement in resolution compared with that of other grazing-incidence devices is attributed to a fortuitous residual on-axis aberration dependence on short wavelengths; recent advances in mirror fabrication, including a new thin-film deposition technique to correct figure errors precisely in one dimension; and novel design. For even higher resolution, a means of creating precise aspherical mirrors of spheric-quality microroughness may be possible by use of the same deposition technique

  20. Measurement of characteristic to total spectrum ratio of tungsten X-ray spectra for the validation of the modified Tbc model

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, A. H.; Costa, P. R. [University of Sao Paulo, Institute of Physics, Laboratory of Radiation Dosimetry and Medical Physics, Matao Street, alley R, 187, 66318 Sao Paulo (Brazil); Tomal, A., E-mail: ahlopezg@usp.br [Universidade Federal de Goias, Physics Institute, Campus Samambaia, 131 Goiania, Goias (Brazil)

    2014-08-15

    Primary X-ray spectra were measured in the range of 80 to 150 kV in order to validate a computer program based on a semiempirical model for X-ray spectra evaluation(tbc and mod). The ratio between the characteristic lines and total spectrum was considered for comparing the simulated results and experimental data. The raw spectra measured by the Cd Te detector were corrected by the detector efficiency, Compton effects and characteristic Cd and Te X-rays escape peaks, using a software specifically developed. The software Origin 8.5.1 was used to calculate the spectra and characteristic peaks areas. The obtained result shows that the experimental spectra have higher effective energy than the simulated spectra computed with tbc and mod software. The behavior of the ratio between the characteristic lines and total spectrum for simulated data presents discrepancy with the experimental result. Computed results are in good agreement with theoretical data published by Green, for spectra obtained with 3.04 mm of additional aluminum filtration. The difference of characteristic to total spectrum ratio between experimental and simulated data increases with the tube voltage. (Author)

  1. Measurement of characteristic to total spectrum ratio of tungsten X-ray spectra for the validation of the modified Tbc model

    International Nuclear Information System (INIS)

    Lopez G, A. H.; Costa, P. R.; Tomal, A.

    2014-08-01

    Primary X-ray spectra were measured in the range of 80 to 150 kV in order to validate a computer program based on a semiempirical model for X-ray spectra evaluation(tbc and mod). The ratio between the characteristic lines and total spectrum was considered for comparing the simulated results and experimental data. The raw spectra measured by the Cd Te detector were corrected by the detector efficiency, Compton effects and characteristic Cd and Te X-rays escape peaks, using a software specifically developed. The software Origin 8.5.1 was used to calculate the spectra and characteristic peaks areas. The obtained result shows that the experimental spectra have higher effective energy than the simulated spectra computed with tbc and mod software. The behavior of the ratio between the characteristic lines and total spectrum for simulated data presents discrepancy with the experimental result. Computed results are in good agreement with theoretical data published by Green, for spectra obtained with 3.04 mm of additional aluminum filtration. The difference of characteristic to total spectrum ratio between experimental and simulated data increases with the tube voltage. (Author)

  2. X-ray photoelectron spectra and electronic structure of quasi-one-dimensional SbSeI crystals

    Directory of Open Access Journals (Sweden)

    J.Grigas

    2007-01-01

    Full Text Available The paper presents the X-ray photoelectron spectra (XPS of the valence band (VB and of the principal core levels from the (110 and (001 crystal surfaces for the quasi-one-dimensional high permittivity SbSeI single crystal isostructural to ferroelectric SbSI. The XPS were measured with monochromatized Al Ka radiation in the energy range of 0-1400 eV at room temperature. The VB is located from 1.6 to 20 eV below the Fermi level. Experimental energies of the VB and core levels are compared with the results of theoretical ab initio calculations of the molecular model of the SbSeI crystal. The electronic structure of the VB is revealed. Shifts in the core-level binding energies of surface atoms relative to bulk ones, which show a dependency on surface crystallography, have been observed. The chemical shifts of the core levels (CL in the SbSeI crystal for the Sb, I and Se states are obtained.

  3. Application of an expectation maximization method to the reconstruction of X-ray-tube spectra from transmission data

    Energy Technology Data Exchange (ETDEWEB)

    Endrizzi, M., E-mail: m.endrizzi@ucl.ac.uk [Dipartimento di Fisica, Università di Siena, Via Roma 56, 53100 Siena (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Delogu, P. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Dipartimento di Fisica “E. Fermi”, Università di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Oliva, P. [Dipartimento di Chimica e Farmacia, Università di Sassari, via Vienna 2, 07100 Sassari (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Cagliari, s.p. per Monserrato-Sestu Km 0.700, 09042 Monserrato (Italy)

    2014-12-01

    An expectation maximization method is applied to the reconstruction of X-ray tube spectra from transmission measurements in the energy range 7–40 keV. A semiconductor single-photon counting detector, ionization chambers and a scintillator-based detector are used for the experimental measurement of the transmission. The number of iterations required to reach an approximate solution is estimated on the basis of the measurement error, according to the discrepancy principle. The effectiveness of the stopping rule is studied on simulated data and validated with experiments. The quality of the reconstruction depends on the information available on the source itself and the possibility to add this knowledge to the solution process is investigated. The method can produce good approximations provided that the amount of noise in the data can be estimated. - Highlights: • An expectation maximization method was used together with the discrepancy principle. • The discrepancy principle is a suitable criterion for stopping the iteration. • The method can be applied to a variety of detectors/experimental conditions. • The minimum information required is the amount of noise that affects the data. • Improved results are achieved by inserting more information when available.

  4. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  5. X-ray absorption and infrared spectra of water and ice: A first-principles electronic structure study

    Science.gov (United States)

    Chen, Wei

    Water is of essential importance for chemistry and biology, yet the physics concerning many of its distinctive properties is not well known. In this thesis we present a theoretical study of the x-ray absorption (XA) and infrared (IR) spectra of water in liquid and solid phase. Our theoretical tools are the density functional theory (DFT), Car-Parrinello (CP) molecular dynamics (MD), and the so-called GW method. Since a systematic review of these ab initio methods is not the task of this thesis, we only briefly recall the main concepts of these methods as needed in the course of our exposition. The focus is, instead, an investigation of what is the important physics necessary for a better description of these excitation processes, in particular, core electron excitations (in XA) that reveal the local electronic structure, and vibrational excitations (in IR) associated to the molecular dynamics. The most interesting question we are trying to answer is: as we include better approximations and more complete physical descriptions of these processes, how do the aforementioned spectra reflect the underlying hydrogen-bonding network of water? The first part of this thesis consists of the first four chapters, which focus on the study of core level excitation of water and ice. The x-ray absorption spectra of water and ice are calculated with a many-body approach for electron-hole excitations. The experimental features, even the small effects of a temperature change in the liquid, are reproduced with quantitative detail using molecular configurations generated by ab initio molecular dynamics. We find that the spectral shape is controlled by two major modifications of the short range order that mark the transition from ice to water. One is associated to dynamic breaking of the hydrogen bonds which leads to a strong enhancement of the pre-edge intensity in the liquid. The other is due to densification, which follows the partial collapse of the hydrogen bond network and is

  6. Understanding Breaks in Flare X-Ray Spectra: Evaluation of a Cospatial Collisional Return-current Model

    Science.gov (United States)

    Alaoui, Meriem; Holman, Gordon D.

    2017-12-01

    Hard X-ray (HXR) spectral breaks are explained in terms of a one-dimensional model with a cospatial return current. We study 19 flares observed by the Ramaty High Energy Solar Spectroscopic Imager with strong spectral breaks at energies around a few deka-keV, which cannot be explained by isotropic albedo or non-uniform ionization alone. We identify these breaks at the HXR peak time, but we obtain 8 s cadence spectra of the entire impulsive phase. Electrons with an initially power-law distribution and a sharp low-energy cutoff lose energy through return-current losses until they reach the thick target, where they lose their remaining energy through collisions. Our main results are as follows. (1) The return-current collisional thick-target model provides acceptable fits for spectra with strong breaks. (2) Limits on the plasma resistivity are derived from the fitted potential drop and deduced electron-beam flux density, assuming the return current is a drift current in the ambient plasma. These resistivities are typically 2–3 orders of magnitude higher than the Spitzer resistivity at the fitted temperature, and provide a test for the adequacy of classical resistivity and the stability of the return current. (3) Using the upper limit of the low-energy cutoff, the return current is always stable to the generation of ion-acoustic and electrostatic ion-cyclotron instabilities when the electron temperature is nine times lower than the ion temperature. (4) In most cases, the return current is most likely primarily carried by runaway electrons from the tail of the thermal distribution rather than by the bulk drifting thermal electrons. For these cases, anomalous resistivity is not required.

  7. Formation and evaluation of convex-curved crystals of lithium fluoride for use in analyzing x-ray spectra

    International Nuclear Information System (INIS)

    Sellick, B.O.

    1976-01-01

    Lithium fluoride as received from the vendor in boule form is 38 x 38 x 13 mm thick. This block is cleaved to wafers of the desired thickness, x-ray-evaluated for ''d'' spacing and greatest intensity, bent to the required radius, and then acid-etched to remove foreign material. The diffraction and dispersion characteristics of a wafer are analyzed using well-collimated tungsten x rays that strike the crystal and are diffracted onto no-screen x-ray film. If the crystal is satisfactory, it is mounted in a spectrogoniometer and rotated through an x-ray beam while a detector is set at the optimized angle for the diffracted x rays. The average intensity across the length of the crystal is recorded by multichannel scaling. Any imperfections appear as peaks or dips compared to the average intensity. The crystal next goes to a 10-channel, filter-fluorescer x-ray unit that compares zero-order intensity to diffracted Kα and Kβ intensity. Counts for 100-s intervals are taken in groups of three and averaged. Correction factors for instrument geometry, air, pinhole diameter at zero order, Kα-Kβ, barometric pressure, temperature, etc., are added to the efficiency calculations to obtain the crystal efficiency (epsilon) vs keV data. The crystal is mounted in the spectrograph or spectrometer and calibrated to either the detector or film plane by using direct radiation with proper x-ray filters or absorbers. The crystal is then ready for use

  8. First-principles calculations of K-shell X-ray absorption spectra for warm dense nitrogen

    International Nuclear Information System (INIS)

    Li, Zi; Zhang, Shen; Kang, Wei; Wang, Cong; Zhang, Ping

    2016-01-01

    X-ray absorption spectrum is a powerful tool for atomic structure detection on warm dense matter. Here, we perform first-principles molecular dynamics and X-ray absorption spectrum calculations on warm dense nitrogen along a Hugoniot curve. From the molecular dynamics trajectory, the detailed atomic structures are examined for each thermodynamical condition. The K-shell X-ray absorption spectrum is calculated, and its changes with temperature and pressure along the Hugoniot curve are discussed. The warm dense nitrogen systems may contain isolated nitrogen atoms, N 2 molecules, and nitrogen clusters, which show quite different contributions to the total X-ray spectrum due to their different electron density of states. The changes of X-ray spectrum along the Hugoniot curve are caused by the different nitrogen structures induced by the temperature and the pressure. Some clear signatures on X-ray spectrum for different thermodynamical conditions are pointed out, which may provide useful data for future X-ray experiments.

  9. ULX spectra revisited: Accreting, highly magnetized neutron stars as the engines of ultraluminous X-ray sources

    Science.gov (United States)

    Koliopanos, Filippos; Vasilopoulos, Georgios; Godet, Olivier; Bachetti, Matteo; Webb, Natalie A.; Barret, Didier

    2017-12-01

    Aims: In light of recent discoveries of pulsating ultraluminous X-ray sources (ULXs) and recently introduced theoretical schemes that propose neutron stars (NSs) as the central engines of ULXs, we revisit the spectra of eighteen well known ULXs, in search of indications that favour this newly emerging hypothesis. Methods: We examine the spectra from high-quality XMM-Newton and NuSTAR observations. We use a combination of elementary black body and multicolour disk black body (MCD) models, to diagnose the predictions of classic and novel theoretical models of accretion onto NSs. We re-interpret the well established spectral characteristics of ULXs in terms of accretion onto lowly or highly magnetised NSs, and explore the resulting parameter space for consistency. Results: We confirm the previously noted presence of the low-energy (≲6 keV) spectral rollover and argue that it could be interpreted as due to thermal emission. The spectra are well described by a double thermal model consisting of a "hot" (≳1 keV) and a "cool" (≲0.7 keV) multicolour black body (MCB). Under the assumption that the "cool" MCD emission originates in a disk truncated at the neutron star magnetosphere, we find that all ULXs in our sample are consistent with accretion onto a highly magnetised (B ≳ 1012 G) neutron star. We note a strong correlation between the strength of the magnetic field, the temperature of the "hot" thermal component and the total unabsorbed luminosity. Examination of the NuSTAR data supports this interpretation and also confirms the presence of a weak, high-energy (≳15 keV) tail, most likely the result of modification of the MCB emission by inverse Compton scattering. We also note that the apparent high-energy tail, may simply be the result of mismodelling of MCB emission with an atypical temperature (T) versus radius (r) gradient, using a standard MCD model with a fixed gradient of T r-0.75. Conclusions: We have offered a new and robust physical interpretation for

  10. Effects of growth conditions on the GaAs/AlAs superlattices by grazing incidence X-ray reflectivity.

    Science.gov (United States)

    Ren, Lingling; Gao, Huifang; Yuan, Aili

    2013-02-01

    The effects of growth conditions on the structural properties of the GaAs/AlAs superlattices were investigated by grazing incidence X-ray reflectivity (GIXRR), transmission electron microscopy (TEM), Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS). The GaAs/AlAs superlattices were prepared by molecular beam epitaxy (MBE) at different growth temperatures (500 degrees C, 600 degrees C and 660 degrees C) and growth rates (1.0 microm/h and 0.7 microm/h for GaAs). And the thicknesses, surface/interface roughnesses and densities of the GaAs/AlAs superlattices were obtained by GIXRR by fitting the whole spectral reflectance curves based on the Parratt recurrence formula. The homogeneity of samples was also studied at different growth conditions. The results indicate that the superlattices grown at a high temperature and large growth rate ratio (rate of AlAs to that of GaAs) possess better structure and more homogeneity.

  11. Diagnosis of secondary caries in esthetic restorations: influence of the incidence vertical angle of the X-ray beam.

    Science.gov (United States)

    Moreira, Patrícia Lima; Messora, Michel Reis; Pereira, Stela Márcia; Almeida, Solange Maria de; Cruz, Adriana Dibo da

    2011-01-01

    The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (A(z)), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (A(z)=0.66, Filtek-Z250>A(z)=0.56, TPH-Spectrum) compared to 0º (A(z)=0.55, Charisma>A(z)=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.

  12. Stress measurements by multi-reflection grazing-incidence X-ray diffraction method (MGIXD) using different radiation wavelengths and different incident angles

    International Nuclear Information System (INIS)

    Marciszko, Marianna; Baczmański, Andrzej; Braham, Chedly; Wróbel, Mirosław; Wroński, Sebastian; Cios, Grzegorz

    2017-01-01

    The presented study introduces the development of the multi-reflection grazing-incidence X-ray diffraction method (MGIXD) for residual stress determination. The proposed new methodology is aimed at obtaining more reliable experimental data and increasing the depth of non-destructive stress determination below the sample surface. To verify proposed method measurements were performed on a classical X-ray diffractometer (Cu Kα radiation) and using synchrotron radiation (three different wavelengths: λ = 1.2527 Å, λ = 1.5419 Å and λ = 1.7512 Å). The Al2017 alloy subjected to three different surface treatments was investigated in this study. The obtained results showed that the proposed development of MGIXD method, in which not only different incident angles but also different wavelengths of X-ray are used, can be successfully applied for residual stress determination, especially when stress gradients are present in the sample.

  13. JGIXA - A software package for the calculation and fitting of grazing incidence X-ray fluorescence and X-ray reflectivity data for the characterization of nanometer-layers and ultra-shallow-implants

    Science.gov (United States)

    Ingerle, D.; Pepponi, G.; Meirer, F.; Wobrauschek, P.; Streli, C.

    2016-04-01

    Grazing incidence XRF (GIXRF) is a very surface sensitive, nondestructive analytical tool making use of the phenomenon of total external reflection of X-rays on smooth polished surfaces. In recent years the method experienced a revival, being a powerful tool for process analysis and control in the fabrication of semiconductor based devices. Due to the downscaling of the process size for semiconductor devices, junction depths as well as layer thicknesses are reduced to a few nanometers, i.e. the length scale where GIXRF is highly sensitive. GIXRF measures the X-ray fluorescence induced by an X-ray beam incident under varying grazing angles and results in angle dependent intensity curves. These curves are correlated to the layer thickness, depth distribution and mass density of the elements in the sample. But the evaluation of these measurements is ambiguous with regard to the exact distribution function for the implants as well as for the thickness and density of nanometer-thin layers. In order to overcome this ambiguity, GIXRF can be combined with X-ray reflectometry (XRR). This is straightforward, as both techniques use similar measurement procedures and the same fundamental physical principles can be used for a combined data evaluation strategy. Such a combined analysis removes ambiguities in the determined physical properties of the studied sample and, being a correlative spectroscopic method, also significantly reduces experimental uncertainties of the individual techniques. In this paper we report our approach to a correlative data analysis, based on a concurrent calculation and fitting of simultaneously recorded GIXRF and XRR data. Based on this approach we developed JGIXA (Java Grazing Incidence X-ray Analysis), a multi-platform software package equipped with a user-friendly graphic user interface (GUI) and offering various optimization algorithms. Software and data evaluation approach were benchmarked by characterizing metal and metal oxide layers on

  14. Charge exchange recombination in X-ray spectra of He-like argon measured at the tokamak TEXTOR

    Energy Technology Data Exchange (ETDEWEB)

    Schlummer, Tobias

    2014-06-16

    Charge exchange recombination between ions and atomic hydrogen is an important atomic process in magnetically confined fusion plasmas. Besides radiative cooling of the plasma edge, charge exchange causes modifications of the ionization balance and the population densities of excited ion states. The central goal of this work is to investigate the influence of charge exchange on X-ray spectra measured at the tokamak TEXTOR. A new 2D X-ray spectrometer developed for future use at the stellarator W7-X was recently installed at TEXTOR. The spectrometer is optimized for measuring the K{sub α}-spectrum of He-like argon (1s2l - 1s{sup 2}) at wavelengths close to 4 Aa. K{sub α}-spectroscopy on He-like impurity ions is an established diagnostic for electron and ion temperature measurements in fusion plasmas. Still, up to now the observed intensity ratios of the K{sub α}-lines and their associated satellites are not fully understood. They show significant deviations from the predictions made by basic corona models. In the past charge exchange with the neutral particle background and radial impurity transport have been discussed as likely explanations. Yet a detailed description of the experimental spectra still has not been achieved. To reconstruct the 2D K{sub α}-spectra measured at TEXTOR the radial argon ion distribution is modeled using an impurity transport code. The model accounts for charge exchange and transport on basis of given radial profiles of the neutral particle density n{sub 0}(r) and the diffusion coefficient D {sub perpendicular} {sub to} (r). The theoretical spectrum is then constructed based on the processes relevant for line emission. Within an iterative procedure n{sub 0}(r) and D {sub perpendicular} {sub to} (r) are varied until consistency between the theoretical and the experimental spectra is achieved. It is shown that the 2D K{sub α}-spectra allow a clear distinction of charge exchange and transport effects, ensuring unique solutions for n

  15. Imaging Grating SpectroPhotometer (I-GRASP) for Solar Soft X-Ray Spectra and Images from a Cube Sat Mission

    Science.gov (United States)

    Didkovsky, Leonid V.; Wieman, Seth; Woods, Thomas N.; Jones, Andrew; Chao, Weilun

    2016-05-01

    We describe the Soft X-ray Imaging Grating SpectroPhotometer (I-GRASP), a novel spectrophotometer with four times narrower transmission grating period (about 50 nm) compared to the MIT-designed 200 nm gratings successfully used for the SOHO/SEM, the SDO/EVE/ESP, and the Solar Aspect Monitor (SAM) onboard the EVE sounding rocket suite of instruments. The new grating is based on technology developed at the Lawrence Berkeley National Laboratory (LBNL) and provides four to five time greater diffraction dispersion than the 200 nm period gratings. Such new technology will provide detection of both 0.1 nm - resolved solar spectra in about 1.0 to 7.0 nm spectral range and a soft X-ray pin-hole solar image from the I-GRASP instrument that is appropriately sized for a CubeSat platform. The solar observations of this soft X-ray range do not currently have spectral resolution, so I-GRASP concurrent spectral and imaging X-ray observations will be important for:Improvements in modeling of coronal dynamics and heating by comparing measured and modeled spectra through identifying changes in abundances from different active regions- Resolving some differences in certain iron spectral line intensity ratios observed with SAM, identifying key emission lines, and comparing to those modeled with the CHIANTI atomic database- Studying SXR spectral variability for different solar activity periods including solar flares and the 27-day solar rotation- Studying of the Earth’s ionosphere, thermosphere and mesosphere responses using as input the detailed soft X-ray spectra from I-GRASP- Improving solar soft X-ray reference spectra for accurate calculations of absolute solar irradiance from the SDO/EVE/ESP, SDO/EVE/SAM, TIMED/SEE/XPS, and SORCE/XPS channels that have broadband measurements of the 1-7 nm band- Providing validation for the soft X-Ray observations from the MinXSS CubeSat X123 spectrometer (0.04 to 2.5 nm) with the I-GRASP spectral observations from 1.0 to 7.0 nm- Comparing I

  16. Comparison of theoretically predicted and observed Solar Maximum Mission X-ray spectra for the 1980 April 13 and May 9 flares

    International Nuclear Information System (INIS)

    Smith, D.F.; Orwig, L.E.

    1982-01-01

    A method for predicting the hard X-ray spectrum in the 10--100 keV range for compact flares during their initial rise is developed on the basis of a thermal model. Observations of the flares of 1980 April 13, 4:05 U.T., and 1980 May 9, 7:12 U.T. are given and their combined spectra from the Hard X-ray Burst Spectrometer and Hard X-ray Imaging Spectrometer on the Solar Maximum Mission are deduced. Constraints on the cross sectional area of the supposed emitting arch are obtained from data from the Hard X-ray Imaging Spectrometer. A power-law spectrum is predicted for the rise of the flare of April 13 for initial arch densities less than 10 10 cm -3 and also for the flare of May 9 for initial arch densities less than 5.4 x 10 10 cm -3 . In both cases power-law spectra are observed. Limitations and implications of these results are discussed

  17. Nondestructive quantitative synchrotron grazing incidence x-ray scattering analysis of cylindrical nanostructures in supported thin films

    International Nuclear Information System (INIS)

    Yoon, J.; Yang, S. Y.; Lee, B.; Joo, W.; Heo, K.; Kim, J. K.; Ree, M.; X-Ray Science Division; Pohang Univ. of Science and Technology

    2007-01-01

    Nondestructive nanostructural analysis is indispensable in the development of nanomaterials and nanofabrication processes for use in nanotechnology applications. This paper demonstrates a quantitative, nondestructive analysis of nanostructured thin films supported on substrates and their templated nanopores by using grazing incidence X-ray scattering and data analysis with a derived scattering theory. The analysis disclosed that vertically oriented nanodomain cylinders had formed in 20-100 nm thick films supported on substrates, which consisted of a mixture of poly(styrene-b-methyl methacrylate) (PS-b-PMMA) and PMMA homopolymer, and that the PMMA nanodomain cylinders were selectively etched out by ultraviolet light exposure and a subsequent rinse with acetic acid, resulting in a well ordered nanostructure consisting of hexagonally packed cylindrical nanopores

  18. Computer-Controlled Cylindrical Polishing Process for Development of Grazing Incidence Optics for Hard X-Ray Region

    Science.gov (United States)

    Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.

  19. Depth profile characterization of electrodeposited multi-thin-film structures by low angle of incidence X-ray diffractometry

    International Nuclear Information System (INIS)

    Nauer, M.; Ernst, K.; Kautek, W.; Neumann-Spallart, M.

    2005-01-01

    Typical structures of heterojunction photovoltaic cells were prepared by sequential electrodeposition of II-VI semiconductor thin films on a transparent conductor, SnO 2 on glass. The structures comprised a wide bandgap window, ZnSe or ZnTe, a medium bandgap light absorber, CdTe, and an ohmic back contact. It is demonstrated that low incidence angle X-ray diffraction (LIXD) can be successfully used as a process monitoring tool, featuring non-destructive depth profiling and phase characterization of such thin film structures. LIXD results are compared to Secondary Ion Mass Spectroscopy (SIMS) and Scanning Electron Microscopy (SEM) data. Both, SIMS and SEM, corroborate the LIXD results as to layer sequence and presence/absence of intermixing

  20. Structure of a monolayer of molecular rotors on aqueous subphase from grazing-incidence X-ray diffraction.

    Science.gov (United States)

    Kaleta, Jiří; Wen, Jin; Magnera, Thomas F; Dron, Paul I; Zhu, Chenhui; Michl, Josef

    2018-03-23

    In situ grazing-incidence X-ray scattering shows that a monolayer of artificial rod-shaped dipolar molecular rotors produced on the surface of an aqueous subphase in a Langmuir trough has a structure conducive to a 2D ferroelectric phase. The axes of the rotors stand an average of 0.83 nm apart in a triangular grid, perpendicular to the surface within experimental error. They carry 2,3-dichlorophenylene rotators near rod centers, between two decks of interlocked triptycenes installed axially on the rotor axle. The analysis is based first on simultaneous fitting of observed Bragg rods and second on fitting the reflectivity curve with only three adjustable parameters and the calculated rotor electron density, which also revealed the presence of about seven molecules of water near each rotator. Dependent on preparation conditions, a minor and variable amount of a different crystal phase may also be present in the monolayer.

  1. Utilization of the statistics techniques for the analysis of the XPS (X-ray photoelectron spectroscopy) and Auger electronic spectra's deconvolutions

    International Nuclear Information System (INIS)

    Puentes, M.B.

    1987-01-01

    For the analysis of the XPS (X-ray photoelectron spectroscopy) and Auger spectra, it is important to performe the peaks' separation and estimate its intensity. For this purpose, a methodology was implemented, including: a spectrum's filter; b) substraction of the base line (or inelastic background); c) deconvolution (separation of the distribution that integrates the spectrum) and d) error of calculation of the mean estimation, comprising adjustment quality tests. A software (FORTRAN IV plus) that permits to use the methodology proposed from the experimental spectra was implemented. The quality of the methodology was tested with simulated spectra. (Author) [es

  2. Tungsten anode spectral model using interpolating cubic splines: unfiltered x-ray spectra from 20 kV to 640 kV.

    Science.gov (United States)

    Hernandez, Andrew M; Boone, John M

    2014-04-01

    Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R(2)) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, "Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector," Phys. Med. Biol. 24, 505-517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9 keV at 20 kV and 169 keV at 640 k

  3. Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Andrew M. [Biomedical Engineering Graduate Group, University of California Davis, Sacramento, California 95817 (United States); Boone, John M., E-mail: john.boone@ucdmc.ucdavis.edu [Departments of Radiology and Biomedical Engineering, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, California 95817 (United States)

    2014-04-15

    Purpose: Monte Carlo methods were used to generate lightly filtered high resolution x-ray spectra spanning from 20 kV to 640 kV. Methods: X-ray spectra were simulated for a conventional tungsten anode. The Monte Carlo N-Particle eXtended radiation transport code (MCNPX 2.6.0) was used to produce 35 spectra over the tube potential range from 20 kV to 640 kV, and cubic spline interpolation procedures were used to create piecewise polynomials characterizing the photon fluence per energy bin as a function of x-ray tube potential. Using these basis spectra and the cubic spline interpolation, 621 spectra were generated at 1 kV intervals from 20 to 640 kV. The tungsten anode spectral model using interpolating cubic splines (TASMICS) produces minimally filtered (0.8 mm Be) x-ray spectra with 1 keV energy resolution. The TASMICS spectra were compared mathematically with other, previously reported spectra. Results: Using pairedt-test analyses, no statistically significant difference (i.e., p > 0.05) was observed between compared spectra over energy bins above 1% of peak bremsstrahlung fluence. For all energy bins, the correlation of determination (R{sup 2}) demonstrated good correlation for all spectral comparisons. The mean overall difference (MOD) and mean absolute difference (MAD) were computed over energy bins (above 1% of peak bremsstrahlung fluence) and over all the kV permutations compared. MOD and MAD comparisons with previously reported spectra were 2.7% and 9.7%, respectively (TASMIP), 0.1% and 12.0%, respectively [R. Birch and M. Marshall, “Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector,” Phys. Med. Biol. 24, 505–517 (1979)], 0.4% and 8.1%, respectively (Poludniowski), and 0.4% and 8.1%, respectively (AAPM TG 195). The effective energy of TASMICS spectra with 2.5 mm of added Al filtration ranged from 17 keV (at 20 kV) to 138 keV (at 640 kV); with 0.2 mm of added Cu filtration the effective energy was 9

  4. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  5. Modified LCAO interpolation method. Calculation of density of states and x-ray emission spectra of non-stopichiometric titanium and vanadium carbides

    International Nuclear Information System (INIS)

    Ivashchenko, V.I.

    1990-01-01

    A modified variant of LCAO-interpolation scheme for the calculation of electronic spectra of transition metal compounds with NaCl-type structure has been suggested. By the method of coherent potential in combination with LCAO-interpolation scheme partial densities of states and X-ray K β 5 - and L 111 -spectra of metal in TiC x (x=1.0; 0.9; 0.8; 0.7) and VC x (x=1.0; 0.88; 0.8; 0.73) have been calculated. The influence of carbon vacancies on electronic spectrum and shape of X-ray emission bands of titanium and vanadium carbides has been studied. The data obtained are compared with calculation results of other authors and experimental characteristics

  6. Measurements of Soft-X-Ray Spectra in Ecr-Heated Tokamak Plasmas and a Comparison with Fokker-Planck Simulations

    NARCIS (Netherlands)

    Da Cruz, D. F.; Peeters, A.G.; Donne, A. J. H.; Cardozo, N. J. L.; Westerhof, E.

    1993-01-01

    Soft x-ray spectra have been measured in the RTP tokamak both during the ohmic phase for densities 2 X 10(19) less-than-or-equal-to n(e)(0) less-than-or-equal-to 7 X 10(19) m-3, and during the ECRH phase at a density n(e)(0) = 2 X 10(19) m-3 for several power levels. Large deformations of the soft

  7. Spectra of molecular changes induced in DNA of Drosophila spermatozoa by 1-ethyl-1-nitrosourea and X-rays

    International Nuclear Information System (INIS)

    Batzer, M.A.; Fossett, N.G.; Lee, W.R.; Louisiana State Univ., Baton Rouge; Tedeschi, B.; Tucker, A.; Kilroy, G.; Arbour, P.

    1988-01-01

    Mutations induced in Drosophila spermatozoa at the alcohol dehydrogenase Adh locus by 1-ethyl-1-nitrosourea (ENU) were compared to X-ray-induced mutations using genetic tests for complementation, southern blotting, western blotting and northern blotting. 8 of 10 ENU-induced mutations complemented all known adjacent loci and were presumed to be intragenic. In contrast, 8 of 30 X-ray-induced mutations were intragenic. The interpretation of these results is that in spermatozoa X-rays induce primarily deletions that either produce deficiencies of the Adh locus or nonsense mutations within the locus, whereas ENU induces primarily missense mutations. This forward mutation assay based on loss of enzymatic activity efficiently recovered a broad spectrum of mutations ranging from missense to intragenic deletions and multi-locus deficiencies. Only 3 of these 40 mutations produced a polypeptide detectable as an electrophoretic variant. 37 refs.; 6 figs.; 2 tabs

  8. Damage thresholds for blaze diffraction gratings and grazing incidence optics at an X-ray free-electron laser.

    Science.gov (United States)

    Krzywinski, Jacek; Conley, Raymond; Moeller, Stefan; Gwalt, Grzegorz; Siewert, Frank; Waberski, Christoph; Zeschke, Thomas; Cocco, Daniele

    2018-01-01

    The Linac Coherent Light Source is upgrading its machine to high repetition rate and to extended ranges. Novel coatings, with limited surface oxidation, which are able to work at the carbon edge, are required. In addition, high-resolution soft X-ray monochromators become necessary. One of the big challenges is to design the mirror geometry and the grating profile to have high reflectivity (or efficiency) and at the same time survive the high peak energy of the free-electron laser pulses. For these reasons the experimental damage threshold, at 900 eV, of two platinum-coated gratings with different blazed angles has been investigated. The gratings were tested at 1° grazing incidence. To validate a model for which the damage threshold on the blaze grating can be estimated by calculating the damage threshold of a mirror with an angle of incidence identical to the angle of incidence on the grating plus the blaze angle, tests on Pt-coated substrates have also been performed. The results confirmed the prediction. Uncoated silicon, platinum and SiB 3 (both deposited on a silicon substrate) were also investigated. In general, the measured damage threshold at grazing incidence is higher than that calculated under the assumption that there is no energy transport from the volume where the photons are absorbed. However, it was found that, for the case of the SiB 3 coating, the grazing incidence condition did not increase the damage threshold, indicating that the energy transport away from the extinction volume is negligible.

  9. Experimental and theoretical correlations between vanadium K-edge X-ray absorption and Kβ emission spectra.

    Science.gov (United States)

    Rees, Julian A; Wandzilak, Aleksandra; Maganas, Dimitrios; Wurster, Nicole I C; Hugenbruch, Stefan; Kowalska, Joanna K; Pollock, Christopher J; Lima, Frederico A; Finkelstein, Kenneth D; DeBeer, Serena

    2016-09-01

    A series of vanadium compounds was studied by K-edge X-ray absorption (XAS) and K[Formula: see text] X-ray emission spectroscopies (XES). Qualitative trends within the datasets, as well as comparisons between the XAS and XES data, illustrate the information content of both methods. The complementary nature of the chemical insight highlights the success of this dual-technique approach in characterizing both the structural and electronic properties of vanadium sites. In particular, and in contrast to XAS or extended X-ray absorption fine structure (EXAFS), we demonstrate that valence-to-core XES is capable of differentiating between ligating atoms with the same identity but different bonding character. Finally, density functional theory (DFT) and time-dependent DFT calculations enable a more detailed, quantitative interpretation of the data. We also establish correction factors for the computational protocols through calibration to experiment. These hard X-ray methods can probe vanadium ions in any oxidation or spin state, and can readily be applied to sample environments ranging from solid-phase catalysts to biological samples in frozen solution. Thus, the combined XAS and XES approach, coupled with DFT calculations, provides a robust tool for the study of vanadium atoms in bioinorganic chemistry.

  10. STRONG MAGNETIC-X-RAY DICHROISM IN 2P ABSORPTION-SPECTRA OF 3D TRANSITION-METAL IONS

    NARCIS (Netherlands)

    VANDERLAAN, G; THOLE, BT

    1991-01-01

    From atomic calculations in crystal-field symmetry we find a very strong circular and linear dichroism in the 2p x-ray absorption edges of magnetically ordered 3d transition-metal ions. The spectral shape changes drastically with the character of the ground state, which is determined by the presence

  11. Oxygen x-ray emission and absorption spectra as a probe of the electronic structure of strongly correlated oxides

    Czech Academy of Sciences Publication Activity Database

    Kurmaev, E.Z.; Wilks, R.G.; Moewes, A.; Finkelstein, L.D.; Shamin, S.N.; Kuneš, Jan

    2008-01-01

    Roč. 77, č. 16 (2008), 165127/1-165127/5 ISSN 1098-0121 Institutional research plan: CEZ:AV0Z10100521 Keywords : transition metal oxides * x-ray spectroscopy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.322, year: 2008

  12. P3HT/PCBM polymer thin films studied by synchrotron-based grazing incidence X-ray diffraction

    International Nuclear Information System (INIS)

    Yang Yingguo; Zhengguan Haojie; Ji Gengwu; Feng Shanglei; Li Xiaolong; Gao Xingyu

    2014-01-01

    Background: The microstructures of P3HT (poly(3-hexyl-thiophene)) in P3HT/PCBM ([6, 6]-phenyl C61-butyric acid methyl ester) thin films play a key role in governing the performance of organic solar cells (OSCs) based on these films. Purpose: We aim to study the self-organization of P3HT in the P3HT/PCBM thin films annealed at different temperatures. Methods: Using different incidence angles, information about the microstructures of P3HT at different depths in these films was obtained by synchrotron based grazing incidence X-ray diffraction (GIXRD). Results: It is shown that the crystalline structure of P3HT has been substantially improved by thermal annealing. One dimensional GIXRD clearly indicates that P3HT edge-on structures in the inner layers have been improved with their number increased in comparison with those at the surface and the interface layers. In addition, thermal annealing also helps the formation of P3HT face-on structures in the films, as evidenced by 2 dimensional GIXRD. Conclusion: The improved structures in these films lead to more charge transport channels formed to improve the carrier mobility, which in turn helps the improvement of OSCs. Thus, the present GIXRD results will improve the understanding of annealing effects at different depths of the P3HT/PCBM thin films for enhanced OSCs devices. (authors)

  13. Nitrogen K-edge X-ray absorption near edge structure (XANES) spectra of purine-containing nucleotides in aqueous solution

    International Nuclear Information System (INIS)

    Shimada, Hiroyuki; Fukao, Taishi; Minami, Hirotake; Ukai, Masatoshi; Fujii, Kentaro; Yokoya, Akinari; Fukuda, Yoshihiro; Saitoh, Yuji

    2014-01-01

    The N K-edge X-ray absorption near edge structure (XANES) spectra of the purine-containing nucleotide, guanosine 5 ′ -monophosphate (GMP), in aqueous solution are measured under various pH conditions. The spectra show characteristic peaks, which originate from resonant excitations of N 1s electrons to π* orbitals inside the guanine moiety of GMP. The relative intensities of these peaks depend on the pH values of the solution. The pH dependence is explained by the core-level shift of N atoms at specific sites caused by protonation and deprotonation. The experimental spectra are compared with theoretical spectra calculated by using density functional theory for GMP and the other purine-containing nucleotides, adenosine 5 ′ -monophosphate, and adenosine 5 ′ -triphosphate. The N K-edge XANES spectra for all of these nucleotides are classified by the numbers of N atoms with particular chemical bonding characteristics in the purine moiety

  14. Traditional x-ray imaging

    International Nuclear Information System (INIS)

    Hay, G.A.

    1982-01-01

    Methods of imaging x-rays, with particular reference to medicine, are reviewed. The history and nature of x-rays, their production and spectra, contrast, shapes and fine structure, image transducers, including fluorescent screens, radiography, fluoroscopy, and image intensifiers, image detection, perception and enhancement and clinical applications are considered. (U.K.)

  15. Rapid and non-destructive analysis of metallic dental restorations using X-ray fluorescence spectra and light-element sampling tools

    Science.gov (United States)

    Furuhashi, K.; Uo, M.; Kitagawa, Y.; Watari, F.

    2012-12-01

    IntroductionRecently, allergic diseases caused by dental metals have been increasing. Therefore, rapid and accurate analytical methods for the metal restorations in the oral cavities of patients are required. The purpose of this study was to develop a non-destructive extraction method for dental alloys, along with a subsequent, rapid and accurate elemental analysis. Materials and methodSamples were obtained by polishing the surfaces of metal restorations using a dental rotating tool with disposable buffs and polishing pastes. As materials for the analysis, three dental alloys were used. To compare the sampling and analysis efficiencies, two buffs and seven pastes were used. After polishing the surface of a metal restoration, the buff was analyzed using X-ray scanning analytical microscopy (XSAM). ResultsThe efficiency of the analysis was judged based on the sampling rate achieved and the absence of disturbing elements in the background in fluorescence X-ray spectra. The best results were obtained for the combination of TexMet as a buff with diamond as a paste. This combination produced a good collection efficiency and a plain background in the fluorescence X-ray spectra, resulting in a high precision of the analysis.

  16. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  17. The fluctuating population of Sm 4f configurations in topological Kondo insulator SmB6 explored with high-resolution X-ray absorption and emission spectra.

    Science.gov (United States)

    Lee, Jenn-Min; Haw, Shu-Chih; Chen, Shi-Wei; Chen, Shin-Ann; Ishii, Hirofumi; Tsuei, Ku-Ding; Hiraoka, Nozomu; Liao, Yen-Fa; Lu, Kueih-Tzu; Chen, Jin-Ming

    2017-09-12

    High-resolution partial-fluorescence-yield X-ray absorption and resonant X-ray emission spectra were used to characterize the temperature dependence of Sm 4f configurations and orbital/charge degree of freedom in SmB 6 . The variation of Sm 4f configurations responds well to the formed Kondo gap, below 140 K, and an in-gap state, below 40 K. The topological in-gap state is correlated with the fluctuating population of Sm 4f configurations that arises via carrier transfer between 3d 9 4f 6 and 3d 9 4f 5 states; both states are partially delocalized, and the mediating 5d orbital plays the role of a transfer path. Complementary results shown in this work thus manifest the importance of configuration fluctuations and orbital delocalization in the topological surface state of SmB 6 .

  18. Reconstruction of energetic electron spectra in the upper atmosphere: balloon observations of auroral X-rays coordinated with measurements from the EISCAT radar

    International Nuclear Information System (INIS)

    Olafsson, K.J.

    1990-08-01

    Energetic electron precipitation in the auroral zone has been studied using coordinated auroral X-ray measurements from balloons, altitude profiles of the ionospheric electron density measured by the EISCAT radar above the balloons, and cosmic noise absorption data from the Scandinavian riometer network. The data were obtained during the Coordinated EISCAT and Balloon Observations (CEBO) campaign in August 1984. The energy spectral variations of both the X-ray fluxes and the primary precipitating electrons were examined for two precipitation events in the morning sector. As far as reasonably can be concluded from observations of magnetic activity in the auroral zone, and from the temporal development of the energy spectra, the two precipitation events can be interpreted in the frame of present models of energetic electron precipitation on the mordning side of the auroral zone. 96 refs., 70 figs., 11 tabs

  19. Mass attenuation coefficient (μ/ρ), effective atomic number (Z{sub eff}) and measurement of x-ray energy spectra using based calcium phosphate biomaterials: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes Z, M. A.; Da Silva, T. A.; Nogueira, M. S. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, Belo Horizonte 31270-901, Minas Gerais (Brazil); Goncalves Z, E., E-mail: madelon@cdtn.br [Pontifice Catholic University of Minas Gerais, Av. Dom Jose Gaspar 500, Belo Horizonte 30535-901, Minas Gerais (Brazil)

    2015-10-15

    In dentistry, alveolar bone regeneration procedures using based calcium phosphate biomaterials have been shown effective. However,there are not reports in the literature of studies the interaction of low energy radiation in these biomaterials used as attenuator and not being then allowed a comparison between the theoretical values and experimental.The objective of this study was to determine the interaction of radiation parameters of four dental biomaterials - BioOss, Cerasorb M Dental, Straumann Boneceramic and Osteogen for diagnostic radiology qualities. As a material and methods, the composition of the biomaterials was determined by the analytical techniques. The samples with 0.181 cm to 0,297 cm thickness were experimentally used as attenuators for the measurement of the transmitted X-rays spectra in X-ray equipment with 50 to 90 kV range by spectrometric system comprising the Cd Te detector. After this procedure, the mass attenuation coefficient, the effective atomic number were determined and compared between all the specimens analyzed, using the program WinXCOM in the range of 10 to 200 keV. In all strains examined observed that the energy spectrum of x-rays transmitted through the BioOss has the mean energy slightly smaller than the others biomaterials for close thickness. The μ/ρ and Z{sub eff} of the biomaterials showed its dependence on photon energy and atomic number of the elements of the material analyzed. It is concluded according to the methodology employed in this study that the measurements of x-ray spectrum, μ/ρ and Z{sub eff} using biomaterials as attenuators confirmed that the thickness, density, composition of the samples, the incident photon energy are factors that determine the characteristics of radiation in a tissue or equivalent material. (Author)

  20. The influence of mammographic X-ray spectra on absorbed energy distribution in breast: Monte Carlo simulation studies

    International Nuclear Information System (INIS)

    Delis, H.; Spyrou, G.; Tzanakos, G.; Panayiotakis, G.

    2005-01-01

    A mathematical model, based on Monte Carlo simulation, is proposed for deriving absorbed energy and dose distribution in mammography utilizing a mathematical water-like phantom. The model was validated for its accuracy against experimental and published data. The main factor discriminating absorbed energy distribution characteristics among different mammographic techniques was considered the X-ray spectrum. The absorbed energy distribution inside the phantom was investigated via percentage depth dose and isodose curves. The influence of the factors affecting X-ray spectrum (tube voltage, anode material, filter material and thickness) on absorbed energy distribution was examined. The hardness of the beam, due to increase of tube voltage or filtration, was found to be the major factor affecting absorbed energy distribution inside the phantom. In general, Mo and W anode systems demonstrated superior dosimetric characteristics against those of W-Mo or Rh. The model presented can be used for estimating absolute and relative breast dose values and their spatial distributions

  1. The influence of mammographic X-ray spectra on absorbed energy distribution in breast: Monte Carlo simulation studies

    Energy Technology Data Exchange (ETDEWEB)

    Delis, H.; Spyrou, G.; Tzanakos, G.; Panayiotakis, G. E-mail: panayiot@upatras.gr

    2005-02-01

    A mathematical model, based on Monte Carlo simulation, is proposed for deriving absorbed energy and dose distribution in mammography utilizing a mathematical water-like phantom. The model was validated for its accuracy against experimental and published data. The main factor discriminating absorbed energy distribution characteristics among different mammographic techniques was considered the X-ray spectrum. The absorbed energy distribution inside the phantom was investigated via percentage depth dose and isodose curves. The influence of the factors affecting X-ray spectrum (tube voltage, anode material, filter material and thickness) on absorbed energy distribution was examined. The hardness of the beam, due to increase of tube voltage or filtration, was found to be the major factor affecting absorbed energy distribution inside the phantom. In general, Mo and W anode systems demonstrated superior dosimetric characteristics against those of W-Mo or Rh. The model presented can be used for estimating absolute and relative breast dose values and their spatial distributions.

  2. Electronic states in Li/sub c/Mg/sub l-c/ alloys: soft x-ray emission spectra

    International Nuclear Information System (INIS)

    Stocks, G.M.; Tagle, J.A.; Callcott, T.A.; Arakawa, E.T.

    1980-01-01

    A first principles theory is developed for Li-Mg alloy systems which avoids the use of pseudo-potentials and, more importantly, low-order perturbation theory and which can be checked quantitatively against detailed probes of the electronic structure such as soft x-ray spectroscopy. These calculations can then be used as a base against which the psuedo-potential methods can, in the future, be checked

  3. Measurement of UO2 surface oxidation using grazing-incidence x-ray diffraction: Implications for nuclear forensics

    Science.gov (United States)

    Tracy, Cameron L.; Chen, Chien-Hung; Park, Sulgiye; Davisson, M. Lee; Ewing, Rodney C.

    2018-04-01

    Nuclear forensics involves determination of the origin and history of interdicted nuclear materials based on the detection of signatures associated with their production and trafficking. The surface oxidation undergone by UO2 when exposed to air is a potential signature of its atmospheric exposure during handling and transport. To assess the sensitivity of this oxidation to atmospheric parameters, surface sensitive grazing-incidence x-ray diffraction (GIXRD) measurements were performed on UO2 samples exposed to air of varying relative humidity (34%, 56%, and 95% RH) and temperature (room temperature, 50 °C, and 100 °C). Near-surface unit cell contraction was observed following exposure, indicating oxidation of the surface and accompanying reduction of the uranium cation ionic radii. The extent of unit cell contraction provides a measure of the extent of oxidation, allowing for comparison of the effects of various exposure conditions. No clear influence of relative humidity on the extent of oxidation was observed, with samples exhibiting similar degrees of unit cell contraction at all relative humidities investigated. In contrast, the thickness of the oxidized layers increased substantially with increasing temperature, such that differences on the order of 10 °C yielded readily observable crystallographic signatures of the exposure conditions.

  4. Investigation of surface and sub-surface damage in high quality synthetic diamonds by X-ray reflectivity and grazing incidence in-plane diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Bussone, Genziana; Lafford, Tamzin A.; Masiello, Fabio; Carbone, Gerardina; Schuelli, Tobias U.; Rommeveaux, Amparo Vivo; Haertwig, Juergen [European Synchrotron Radiation Facility, 6, Rue Jules Horowitz, BP 220, 38043 Grenoble Cedex 9 (France); Gibaud, Alain [Laboratoire PEC, Universite du Maine le Mans, Avenue Olivier Messiaen, 72 085 Le Mans (France); Connell, Simon H. [University of Johannesburg, cnr Kingsway Ave and University Rd, Auckland Park, 2006, Johannesburg (South Africa); Wormington, Matthew [Jordan Valley Semiconductors Inc., 8601 Cross Park Drive, Suite 200, Austin, TX 78754-4578 (United States)

    2011-11-15

    High quality single-crystal synthetic diamond is the most suitable material for selected X-ray optical applications in the latest generation X-ray light sources. Excellent heat handling properties, as well as low absorption, coupled with high perfection in the crystal bulk and very good surface quality, are crucial for such applications. In recent years, some progress has been made in the fields of surface treatments and growth techniques. Conventional scaife polishing is largely ineffective on the diamond (111) surface. To overcome this disadvantage, one possibility is to use the Hot Metal polishing technique. An investigation of surface and sub-surface damage of Hot Metal polished and cleaved surfaces, has been carried out using depth-sensitive non-destructive X-ray techniques. The near surface crystalline quality was studied as a function of depth using in-plane grazing incidence X-ray diffraction. Additionally, X-ray reflectivity was used to investigate the density, thickness and roughness of near-surface layers. The measurements enable us to estimate the thickness of the affected sub-surface layer. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Response of x-ray intensifying screens to scattered and primary radiation

    NARCIS (Netherlands)

    Koedooder, K.; Venema, H. W.

    1984-01-01

    The energy dependence of the luminance ratio due to scattered and primary radiation has been determined for four types of X-ray intensifying screens. A water phantom of 30 cm X 30 cm X 20 cm was used as the scattering medium. Ten narrow band X-ray spectra were used as incident radiation: the mean

  6. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  7. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  8. Analysis of the additional filtration effects in X-ray beams from the calculation of average energy for photon in X-ray spectra; Analise dos efeitos da filtracao adicional em feixes de raios X a partir dos calculos de energia media por foton em espectros de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, Rodrigo F.; Potiens, Maria da Penha A., E-mail: rodrigoifusp@yahoo.com.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-12-15

    The objective of this work was to analyze the behavior of X-ray spectra by calculating the average energy in each spectrum generated for different additional filtrations inserted in the X-ray beam. It was used an X-ray system present in the Laboratory of Instruments Calibration of the Instituto de Pesquisas Energeticas e Nucleares (IPEN) for the generation of X-ray beams, a spectrometry system with a solid state detector (semiconductor) to the data acquisition and aluminum and copper filters, with different thicknesses to be inserted in the output of the X-ray tube. The average energy per photon was calculated integrating the curve of each spectrum and dividing the value by the total number of counts. This calculation enabled to verify that the use of filtration in the X-ray equipment contributes significantly in the average energy of the X-ray beam. Thus, the same dose received by a patient or recorded by a detector has distinct average energies due to the use of filtrations with different materials and thicknesses, which allows the manipulation of X-ray beam through additional filtration. (author)

  9. A Restricted Open Configuration Interaction with Singles Method To Calculate Valence-to-Core Resonant X-ray Emission Spectra: A Case Study.

    Science.gov (United States)

    Maganas, Dimitrios; DeBeer, Serena; Neese, Frank

    2017-10-02

    In this work, a new protocol for the calculation of valence-to-core resonant X-ray emission (VtC RXES) spectra is introduced. The approach is based on the previously developed restricted open configuration interaction with singles (ROCIS) method and its parametrized version, based on a ground-state Kohn-Sham determinant (DFT/ROCIS) method. The ROCIS approach has the following features: (1) In the first step approximation, many-particle eigenstates are calculated in which the total spin is retained as a good quantum number. (2) The ground state with total spin S and excited states with spin S' = S, S ± 1, are obtained. (3) These states have a qualitatively correct multiplet structure. (4) Quasi-degenerate perturbation theory is used to treat the spin-orbit coupling operator variationally at the many-particle level. (5) Transition moments are obtained between the relativistic many-particle states. The method has shown great potential in the field of X-ray spectroscopy, in particular in the field of transition-metal L-edge, which cannot be described correctly with particle-hole theories. In this work, the method is extended to the calculation of resonant VtC RXES [alternatively referred to as 1s-VtC resonant inelastic X-ray scattering (RIXS)] spectra. The complete Kramers-Dirac-Heisenerg equation is taken into account. Thus, state interference effects are treated naturally within this protocol. As a first application of this protocol, a computational study on the previously reported VtC RXES plane on a molecular managanese(V) complex is performed. Starting from conventional X-ray absorption spectra (XAS), we present a systematic study that involves calculations and electronic structure analysis of both the XAS and non-resonant and resonant VtC XES spectra. The very good agreement between theory and experiment, observed in all cases, allows us to unravel the complicated intensity mechanism of these spectroscopic techniques as a synergic function of state polarization

  10. Reconstruction of energetic electron spectra in the upper atmosphere: balloon observations of auroral X-rays coordinated with measurements from the Eiscat radar

    International Nuclear Information System (INIS)

    Olafsson, K.J.

    1990-01-01

    Energetic electron precipitation in the auroral zone has been studied using coordinated auroral X-ray measurements from balloons, altitude profiles of the ionospheric electron density measured by the EISCAT radar above the balloons, and cosmic noise absorption data from the Scandinavian riometer network. The data were obtained during the coordinated EISCAT and balloon observation campaign in August 1984. A method by which an estimate of the energy spectrum of precipitating energetic electrons can be obtained from balloon measurements of bremsstrahlung X-rays is described. The energy spectral variation of both the X-ray fluxes and the primary precipitating electrons were examined for two precipitation events in the morning sector. As far as reasonably can be concluded from observations of magnetic activity in the auroral zone, and from the temporal development of the energy spectra, the two precipitation events can be interpreted in the frame of present models of energetic electron precipitation on the morning side of the auroral zone. 96 refs

  11. Measurement of high-dynamic range x-ray Thomson scattering spectra for the characterization of nano-plasmas at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, M. J., E-mail: macdonm@umich.edu [University of Michigan, Ann Arbor, Michigan 48109 (United States); SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Gorkhover, T. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Technische Universität, 10623 Berlin (Germany); Bachmann, B.; Hau-Riege, S. P.; Pardini, T.; Döppner, T. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Bucher, M. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Argonne National Lab, Lemont, Illinois 60439 (United States); Carron, S. [California Lutheran University, Thousand Oaks, California 91360 (United States); Coffee, R. N.; Fletcher, L. B.; Gamboa, E. J.; Glenzer, S. H.; Göde, S.; Krzywinski, J.; O’Grady, C. P.; Osipov, T.; Swiggers, M. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Ferguson, K. R. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Stanford University, Stanford, California 94305 (United States); Kraus, D. [University of California, Berkeley, California 94720 (United States); and others

    2016-11-15

    Atomic clusters can serve as ideal model systems for exploring ultrafast (∼100 fs) laser-driven ionization dynamics of dense matter on the nanometer scale. Resonant absorption of optical laser pulses enables heating to temperatures on the order of 1 keV at near solid density conditions. To date, direct probing of transient states of such nano-plasmas was limited to coherent x-ray imaging. Here we present the first measurement of spectrally resolved incoherent x-ray scattering from clusters, enabling measurements of transient temperature, densities, and ionization. Single shot x-ray Thomson scattering signals were recorded at 120 Hz using a crystal spectrometer in combination with a single-photon counting and energy-dispersive pnCCD. A precise pump laser collimation scheme enabled recording near background-free scattering spectra from Ar clusters with an unprecedented dynamic range of more than 3 orders of magnitude. Such measurements are important for understanding collective effects in laser-matter interactions on femtosecond time scales, opening new routes for the development of schemes for their ultrafast control.

  12. Non-linearity issues and multiple ionization satellites in the PIXE portion of spectra from the Mars alpha particle X-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, John L., E-mail: icampbel@uoguelph.ca; Heirwegh, Christopher M.; Ganly, Brianna

    2016-09-15

    Spectra from the laboratory and flight versions of the Curiosity rover’s alpha particle X-ray spectrometer were fitted with an in-house version of GUPIX, revealing departures from linear behavior of the energy-channel relationships in the low X-ray energy region where alpha particle PIXE is the dominant excitation mechanism. The apparent energy shifts for the lightest elements present were attributed in part to multiple ionization satellites and in part to issues within the detector and/or the pulse processing chain. No specific issue was identified, but the second of these options was considered to be the more probable. Approximate corrections were derived and then applied within the GUAPX code which is designed specifically for quantitative evaluation of APXS spectra. The quality of fit was significantly improved. The peak areas of the light elements Na, Mg, Al and Si were changed by only a few percent in most spectra. The changes for elements with higher atomic number were generally smaller, with a few exceptions. Overall, the percentage peak area changes are much smaller than the overall uncertainties in derived concentrations, which are largely attributable to the effects of rock heterogeneity. The magnitude of the satellite contributions suggests the need to incorporate these routinely in accelerator-based PIXE using helium beams.

  13. Electronic Raman scattering with excitation between localized states observed in the zinc M{sub 2,3} soft x-ray spectra of ZnS

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, L.; Callcott, T.A.; Jia, J.J. [Univ. of Tennessee, Knoxville, TN (United States)] [and others

    1997-04-01

    Zn M{sub 2,3} soft x-ray fluorescence (SXF) spectra of ZnS and ZnS{sub .5}Se{sub .5} excited near threshold show strong inelastic scattering effects that can be explained using a simple model and an inelastic scattering theory based on second order perturbation theory. This scattering is often called electronic resonance Raman scattering. Tulkki and Aberg have developed this theory in detail for atomic systems, but their treatment can be applied to solid systems by utilizing electronic states characteristic of solids rather than of atomic systems.

  14. Absorption spectra measurements of the x-ray radiation heated SiO2 aerogel plasma in 'dog-bone' targets irradiated by high power laser pulses

    Science.gov (United States)

    Zhang, Y.; Dong, Q.-L.; Wang, S.-J.; Li, Y.-T.; Zhang, J.; Wei, H.-G.; Shi, J.-R.; Zhao, G.; Zhang, J.-Y.; Wen, T.-S.; Zhang, W.-H.; Hu, X.; Liu, S.-Y.; Ding, Y.-K.; Zhang, L.; Tang, Y.-J.; Zhang, B.-H.; Zheng, Z.-J.; Nishimura, H.; Fujioka, S.; Takabe, H.

    2008-05-01

    We studied the opacity effect of the SiO2 aerogel plasma heated by x-ray radiation produced by high power laser pulses irradiating the inner surface of golden 'dog-bone' targets. The PET crystal spectrometer was used to measure the absorption spectra of the plasmas in the range from 6.4 Å to 7.4 Å, among which the line emissions involving the K shell of Si ions from He-like to neutral atom were located. The experimental results were analyzed with Detailed-Level-Accounting method. As the plasma temperature increased, the characteristic lines of highly ionized ions gradually dominated the absorption spectrum.

  15. Impact of Lipid Oxidization on Vertical Structures and Electrostatics of Phospholipid Monolayers Revealed by Combination of Specular X-ray Reflectivity and Grazing-Incidence X-ray Fluorescence.

    Science.gov (United States)

    Korytowski, Agatha; Abuillan, Wasim; Makky, Ali; Konovalov, Oleg; Tanaka, Motomu

    2015-07-30

    The influence of phospholipid oxidization of floating monolayers on the structure perpendicular to the global plane and on the density profiles of ions near the lipid monolayer has been investigated by a combination of grazing incidence X-ray fluorescence (GIXF) and specular X-ray reflectivity (XRR). Systematic variation of the composition of the floating monolayers unravels changes in the thickness, roughness and electron density of the lipid monolayers as a function of molar fraction of oxidized phospholipids. Simultaneous GIXF measurements enable one to qualitatively determine the element-specific density profiles of monovalent (K(+) or Cs(+)) and divalent ions (Ca(2+)) in the vicinity of the interface in the presence and absence of two types of oxidized phospholipids (PazePC and PoxnoPC) with high spatial accuracy (±5 Å). We found the condensation of Ca(2+) near carboxylated PazePC was more pronounced compared to PoxnoPC with an aldehyde group. In contrast, the condensation of monovalent ions could hardly be detected even for pure oxidized phospholipid monolayers. Moreover, pure phospholipid monolayers exhibited almost no ion specific condensation near the interface. The quantitative studies with well-defined floating monolayers revealed how the elevation of lipid oxidization level alters the structures and functions of cell membranes.

  16. Resonant inelastic X-ray scattering spectra at the Ir L-edge in Na{sub 2}IrO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, Jun-ichi, E-mail: junichi.igarashi.kiryu@vc.ibaraki.ac.jp [Faculty of Science, Ibaraki University, Mito, Ibaraki 310-8512 (Japan); Nagao, Tatsuya, E-mail: nagao@gunma-u.ac.jp [Faculty of Engineering, Gunma University, Kiryu, Gunma 376-8515 (Japan)

    2016-10-15

    Highlights: • A theoretical framework of resonant inelastic X-ray scattering (RIXS) on the basis of the itinerant electron scheme has been developed. • The RIXS theory is applied to iridate Na{sub 2}IrO{sub 3}. • The origins of the multi-peak structure of the excitation spectra found in the RIXS experiment have been assigned to the magnetic and excitonic excitations. - Abstract: We analyze resonant X-ray scattering (RIXS) spectra in Na{sub 2}IrO{sub 3} on the basis of the itinerant electron picture. Employing a multi-orbital tight-binding model on a honeycomb lattice, we find that the zigzag magnetic order is the most stable with sizable energy gap in the one-electron band within the Hartree–Fock approximation. We derive the RIXS spectra, which are connected to the generalized density–density correlation function. We calculate the spectra as a function of excitation energy ω, within the random phase approximation. The spectra consist of the peaks with ω < 20 meV, and of the peaks with 0.4 < ω < 0.8 eV. The former peaks are composed of four bound states in the density–density correlation function, and may be identified as the magnetic excitations, while the latter peaks are composed of 16 bound states below the energy continuum of individual electron–hole pair excitations, and may be identified as the excitonic excitations. The calculated spectra agree qualitatively with the recent RIXS experiment.

  17. Vibrational, X-ray absorption, and Mössbauer spectra of sulfate minerals from the weathered massive sulfide deposit at Iron Mountain, California

    Science.gov (United States)

    Majzlan, Juraj; Alpers, Charles N.; Bender Koch, Christian; McCleskey, R. Blaine; Myneni, Satish B.C.; Neil, John M.

    2014-01-01

    The Iron Mountain Mine Superfund site in California is a prime example of an acid mine drainage (AMD) system with well developed assemblages of sulfate minerals typical for such settings. Here we present and discuss the vibrational (infrared), X-ray absorption, and Mössbauer spectra of a number of these phases, augmented by spectra of a few synthetic sulfates related to the AMD phases. The minerals and related phases studied in this work are (in order of increasing Fe2O3/FeO): szomolnokite, rozenite, siderotil, halotrichite, römerite, voltaite, copiapite, monoclinic Fe2(SO4)3, Fe2(SO4)3·5H2O, kornelite, coquimbite, Fe(SO4)(OH), jarosite and rhomboclase. Fourier transform infrared spectra in the region 750–4000 cm−1 are presented for all studied phases. Position of the FTIR bands is discussed in terms of the vibrations of sulfate ions, hydroxyl groups, and water molecules. Sulfur K-edge X-ray absorption near-edge structure (XANES) spectra were collected for selected samples. The feature of greatest interest is a series of weak pre-edge peaks whose position is determined by the number of bridging oxygen atoms between Fe3+ octahedra and sulfate tetrahedra. Mössbauer spectra of selected samples were obtained at room temperature and 80 K for ferric minerals jarosite and rhomboclase and mixed ferric–ferrous minerals römerite, voltaite, and copiapite. Values of Fe2+/[Fe2+ + Fe3+] determined by Mössbauer spectroscopy agree well with those determined by wet chemical analysis. The data presented here can be used as standards in spectroscopic work where spectra of well-characterized compounds are required to identify complex mixtures of minerals and related phases.

  18. Molecular-beam epitaxy growth and structural characterization of semiconductor-ferromagnet heterostructures by grazing incidence X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Satapathy, D.K.

    2005-12-19

    The present work is devoted to the growth of the ferromagnetic metal MnAs on the semiconductor GaAs by molecular-beam epitaxy (MBE). The MnAs thin films are deposited on GaAs by molecular-beam epitaxy (MBE). Grazing incidence diffraction (GID) and reflection high-energy electron diffraction (RHEED) are used in situ to investigate the nucleation, evolution of strain, morphology and interfacial structure during the MBE growth. Four stages of the nucleation process during growth of MnAs on GaAs(001) are revealed by RHEED azimuthal scans. GID shows that further growth of MnAs films proceed via the formation of relaxed islands at a nominal thickness of 2.5 ML which increase in size and finally coalesce to form a continuous film. Early on, an ordered array of misfit dislocations forms at the interface releasing the misfit strain even before complete coalescence occurs. The fascinating complex nucleation process of MnAs on GaAs(0 0 1) contains elements of both Volmer-Weber and Stranski-Krastanov growth. A nonuniform strain amounting to 0.66%, along the [1 -1 0] direction and 0.54%, along the [1 1 0] direction is demonstrated from x-ray line profile analysis. A high correlation between the defects is found along the GaAs[1 1 0] direction. An extremely periodic array of misfit dislocations with a period of 4.95{+-}0.05 nm is formed at the interface along the [1 1 0] direction which releases the 7.5% of misfit. The inhomogeneous strain due to the periodic dislocations is confined at the interface within a layer of 1.6 nm thickness. The misfit along the [1 -1 0] direction is released by the formation of a coincidence site lattice. (orig.)

  19. Microwave imaging of a solar limb flare - Comparison of spectra and spatial geometry with hard X-rays

    Science.gov (United States)

    Schmahl, E. J.; Kundu, M. R.; Dennis, B. R.

    1985-01-01

    A solar limb flare was mapped using the Very Large Array (VLA) together with hard X-ray (HXR) spectral and spatial observations of the Solar Maximum Mission satellite. Microwave flux records from 2.8 to 19.6 GHz were instrumental in determining the burst spectrum, which has a maximum at 10 GHz. The flux spectrum and area of the burst sources were used to determine the number of electrons producing gyrosynchrotron emission, magnetic field strength, and the energy distribution of gyrosynchrotron-emitting electrons. Applying the thick target model to the HXR spectrum, the number of high energy electrons responsible for the X-ray bursts was found to be 10 to the 36th, and the electron energy distribution was approximately E exp -5, significantly different from the parameters derived from the microwave observations. The HXR imaging observations exhibit some similiarities in size and structure o the first two burst sources mapped with the VLA. However, during the initial burst, the HXR source was single and lower in the corona than the double 6 cm source. The observations are explained in terms of a single loop with an isotropic high-energy electron distribution which produced the microwaves, and a larger beamed component which produced the HXR at the feet of the loop.

  20. Effects of chemical combination on x-ray Kα and Kβ1,3 emission spectra of Co

    International Nuclear Information System (INIS)

    Baydas, E; Oez, E

    2010-01-01

    Chemical shift, differences of full width at half maximum (ΔFWHM) and full width at half maximum (FWHM) of Kα and Kβ 1,3 x-ray emission lines were measured for the following Co compounds: Co, CoO, Co 2 O 3 , CoSO 4 .7H 2 O, Co(NO 3 ) 2 .6H 2 O, CoCr 2 O 4 , Co(ClO 4 ) 2 .6H 2 O, Co(C 2 H 3 O 2 ), CoCl 2 .6H 2 O, CoCl 2 , CoF 2 , CoF 2 .4H 2 O and CoF 3 . The measurements were performed with wavelength-dispersive x-ray fluorescence spectrometry (WDXRF). It was found that the calculated results for Co compounds are strongly correlated with the oxidation state. At the same time, chemical shift for F compounds is generally more than that for Cl compounds. Larger chemical shifts and FWHM were also found for Kβ 1,3 lines than Kα ones. It should be noted that the magnitude of chemical shifts increases with the increasing number of ligand atoms.

  1. X-ray diagnostic in gas discharge

    International Nuclear Information System (INIS)

    Chen Suhe; Wang Dalun; Cui Gaoxian; Wang Mei; Fu Yibei; Zhang Xinwei; Zhang Wushou

    1995-01-01

    X rays were observed when the anomalous phenomenon in the metal loaded with deuterium studied by the gas-discharge method. Therefore the X-ray energy spectra were measured by the absorption method, the specific X-ray approach and the NaI scintillation counter, while X-ray intensity was estimated by using 7 Li thermoluminescent foils. The X-ray average energy measured by the absorption method is 27.6 +- 2.1 keV, which is fitted within the error extent to 26.0 +-2.4 keV monoenergetic X rays measured by the NaI scintillation counter

  2. Comparison of x-ray absorption spectra between water and ice: New ice data with low pre-edge absorption cross-section

    Energy Technology Data Exchange (ETDEWEB)

    Sellberg, Jonas A.; Nilsson, Anders [Department of Physics, AlbaNova University Center, Stockholm University, S-106 91 Stockholm (Sweden); SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Kaya, Sarp [SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Segtnan, Vegard H. [SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Nofima AS, N-1430 Ås (Norway); Chen, Chen [SUNCAT Center for Interface Science and Catalysis, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Chemistry, Stanford University, Stanford, California 94305 (United States); Tyliszczak, Tolek [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Ogasawara, Hirohito; Nordlund, Dennis [Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, P.O. Box 20450, Stanford, California 94309 (United States); Pettersson, Lars G. M. [Department of Physics, AlbaNova University Center, Stockholm University, S-106 91 Stockholm (Sweden)

    2014-07-21

    The effect of crystal growth conditions on the O K-edge x-ray absorption spectra of ice is investigated through detailed analysis of the spectral features. The amount of ice defects is found to be minimized on hydrophobic surfaces, such as BaF{sub 2}(111), with low concentration of nucleation centers. This is manifested through a reduction of the absorption cross-section at 535 eV, which is associated with distorted hydrogen bonds. Furthermore, a connection is made between the observed increase in spectral intensity between 544 and 548 eV and high-symmetry points in the electronic band structure, suggesting a more extended hydrogen-bond network as compared to ices prepared differently. The spectral differences for various ice preparations are compared to the temperature dependence of spectra of liquid water upon supercooling. A double-peak feature in the absorption cross-section between 540 and 543 eV is identified as a characteristic of the crystalline phase. The connection to the interpretation of the liquid phase O K-edge x-ray absorption spectrum is extensively discussed.

  3. AN INTEGRATED MODEL FOR THE PRODUCTION OF X-RAY TIME LAGS AND QUIESCENT SPECTRA FROM HOMOGENEOUS AND INHOMOGENEOUS BLACK HOLE ACCRETION CORONAE

    Energy Technology Data Exchange (ETDEWEB)

    Kroon, John J.; Becker, Peter A., E-mail: jkroon@gmu.edu, E-mail: pbecker@gmu.edu [Department of Physics and Astronomy, George Mason University, Fairfax, VA 22030-4444 (United States)

    2016-04-20

    Many accreting black holes manifest time lags during outbursts, in which the hard Fourier component typically lags behind the soft component. Despite decades of observations of this phenomenon, the underlying physical explanation for the time lags has remained elusive, although there are suggestions that Compton reverberation plays an important role. However, the lack of analytical solutions has hindered the interpretation of the available data. In this paper, we investigate the generation of X-ray time lags in Compton scattering coronae using a new mathematical approach based on analysis of the Fourier-transformed transport equation. By solving this equation, we obtain the Fourier transform of the radiation Green’s function, which allows us to calculate the exact dependence of the time lags on the Fourier frequency, for both homogeneous and inhomogeneous coronal clouds. We use the new formalism to explore a variety of injection scenarios, including both monochromatic and broadband (bremsstrahlung) seed photon injection. We show that our model can successfully reproduce both the observed time lags and the time-averaged (quiescent) X-ray spectra for Cyg X-1 and GX 339-04, using a single set of coronal parameters for each source. The time lags are the result of impulsive bremsstrahlung injection occurring near the outer edge of the corona, while the time-averaged spectra are the result of continual distributed injection of soft photons throughout the cloud.

  4. Characterizing high energy spectra of NIF ignition Hohlraums using a differentially filtered high energy multipinhole x-ray imager.

    Science.gov (United States)

    Park, Hye-Sook; Dewald, E D; Glenzer, S; Kalantar, D H; Kilkenny, J D; MacGowan, B J; Maddox, B R; Milovich, J L; Prasad, R R; Remington, B A; Robey, H F; Thomas, C A

    2010-10-01

    Understanding hot electron distributions generated inside Hohlraums is important to the national ignition campaign for controlling implosion symmetry and sources of preheat. While direct imaging of hot electrons is difficult, their spatial distribution and spectrum can be deduced by detecting high energy x-rays generated as they interact with target materials. We used an array of 18 pinholes with four independent filter combinations to image entire Hohlraums with a magnification of 0.87× during the Hohlraum energetics campaign on NIF. Comparing our results with Hohlraum simulations indicates that the characteristic 10-40 keV hot electrons are mainly generated from backscattered laser-plasma interactions rather than from Hohlraum hydrodynamics.

  5. X-ray spectra, chemical bonding, and electron structure of ScM2Si2 (M = Fe, Co, Ni)

    International Nuclear Information System (INIS)

    Shcherba, I.D.; Kotur, B.Ya.

    1990-01-01

    In a study of the interaction of the components in the ternary systems Sc-M-Si (where M is a 3d transition metal) it was established that there are compounds of the empirical formula ScM 2 Si 2 (M = Fe, Co, Ni). They crystallize in two structural types, HfFe 2 Si 2 (the compound ScFe 2 Si 2 ) and CeGa 2 Al 2 (ScCo 2 Si 2 and ScNi 2 Si 2 ) (ref. 1), leading to different coordination environment of the atoms in the structures of the compounds. With the aim of investigating the electron structure and the type ofin these compounds, they authors made a systematic x-ray spectral investigation with simultaneous analysis of the crystal structures of ScM 2 Si 2

  6. Detection of short range order in SiO{sub 2} thin-films by grazing-incidence wide and small-angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Kohki, E-mail: nagata.koki@iri-tokyo.jp [Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064 (Japan); School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Ogura, Atsushi [School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Hirosawa, Ichiro [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Suwa, Tomoyuki; Teramoto, Akinobu; Ohmi, Tadahiro [New Industry Creation Hatchery Center, Tohoku University, 6-6-10 Aramakiazaaoba, Aoba-ku, Sendai, Miyagi 980-8579 (Japan)

    2016-04-21

    The effects of the fabrication process conditions on the microstructure of silicon dioxide thin films of <10 nm thickness are presented. The microstructure was investigated using grazing-incidence wide and small-angle X-ray scattering methods with synchrotron radiation. The combination of a high brilliance light source and grazing incident configuration enabled the observation of very weak diffuse X-ray scattering from SiO{sub 2} thin films. The results revealed different microstructures, which were dependent on oxidizing species or temperature. The micro-level properties differed from bulk properties reported in the previous literature. It was indicated that these differences originate from inner stress. The detailed structure in an amorphous thin film was not revealed owing to detection difficulties.

  7. Crystalline self-assembly of organic molecules with metal ions at the air-aqueous solution interface. A grazing incidence X-ray scattering study

    DEFF Research Database (Denmark)

    Weissbuch, I.; Buller, R.; Kjær, K.

    2002-01-01

    The advent of intense X-rays from synchrotron sources made possible to probe, at the molecular level, the structural aspects of self-assemblies generated at interfaces. Here we present the two-dimensional (2-D) packing arrangements of two-, three- and multi-component organo-metallic self-assembli......The advent of intense X-rays from synchrotron sources made possible to probe, at the molecular level, the structural aspects of self-assemblies generated at interfaces. Here we present the two-dimensional (2-D) packing arrangements of two-, three- and multi-component organo-metallic self......-assemblies formed via interfacial reaction at the air-aqueous solution interface, as determined by grazing incidence X-ray diffraction (GIRD) and X-ray specular reflectivity techniques. GIXD yields structural information on the crystalline part of the Langmuir film, including the ions and counterions lateral order...... of metal ions bound to the polar head groups of amphipilic molecules; use of bolaamphiphiles to generate oriented thin films with metal ions arranged in periodic layers; delineation of differences in the lateral organization of metal ions at interfaces as induced by racemates and enantiomerically pure...

  8. Characterization of surface Ag nanoparticles in nanocomposite a-C:Ag coatings by grazing incidence X-ray diffraction at sub-critical angles of incidence

    Energy Technology Data Exchange (ETDEWEB)

    Manninen, N.K.; Oliveira, J.C.; Cavaleiro, A. [University of Coimbra, SEG-CEMUC, Mechanical Engineering Department, Coimbra (Portugal); Carvalho, S. [University of Minho, GRF-CFUM, Physics Department, Guimaraes (Portugal)

    2016-03-15

    Silver diffusion within nanocomposite films and/or toward the film surface is often observed during annealing of the silver-based nanocomposite films. In order to control and/or minimize this process, it is crucial to characterize the aggregated silver nanoparticles on the films surface. In this paper grazing incidence X-ray diffraction (GIXRD) with both sub-critical and supra-critical angles of incidence is used to characterize the Ag nanoparticles distribution, shape and structure both inside the matrix and on the nanocomposite film surface. The nanocomposite carbon coating containing Ag nanoparticles (a-C:Ag) was deposited by dc magnetron sputtering. The coatings were analyzed by GIXRD using fixed incident angles both below and above the critical angle for total reflection. By using sub-critical angles it was possible to eliminate diffraction from the bulk material allowing to estimate the size distribution of the nanoparticles sitting on the surface. The results obtained by GIXRD analysis were checked through comparison with the observations made by both TEM and SEM analysis. The proposed methodology can be used to characterized nanoparticles deposition on a surface and/or island formation during film growth as long an adequate substrate with high critical angle for total reflection is used. (orig.)

  9. X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Raman, S.; Sparks, C.J. Jr.

    1978-01-01

    An experimental set-up for x-ray fluorescence analysis with synchrotron radiation was built and installed at the Stanford Synchrotron Radiation Project. X-ray spectra were taken from numerous and varied samples in order to assess the potential of synchrotron radiation as an excitation source for multielement x-ray fluorescence analysis. For many applications, the synchrotron radiation technique is shown to be superior to other x-ray fluorescence methods, especially those employing electrons and protons as excitation sources

  10. A combined optical and X-ray study of unobscured type 1 active galactic nuclei - I. Optical spectra and spectral energy distribution modelling

    Science.gov (United States)

    Jin, Chichuan; Ward, Martin; Done, Chris; Gelbord, Jonathan

    2012-03-01

    We present modelling and interpretation of the continuum and emission lines for a sample of 51 unobscured type 1 active galactic nuclei (AGNs). All of these AGNs have high-quality spectra from both XMM-Newton and the Sloan Digital Sky Survey. We extend the wavelength coverage where possible by adding simultaneous ultraviolet data from the OM onboard XMM-Newton. Our sample is selected based on low reddening in the optical and low gas columns implied by their X-ray spectra, except for one case, the broad absorption line quasar PG 1004+130. They also lack clear signatures for the presence of a warm absorber. Therefore, the observed characteristics of this sample are likely to be directly related to the intrinsic properties of the central engine.

  11. Study of X-Ray and $\\gamma$-Ray Spectra from Antiprotonic Atoms at the Slowly Extracted Antiproton Beam of LEAR

    CERN Multimedia

    2002-01-01

    This experiment will study the X-ray spectra of antiprotonic atoms and the $\\gamma$ spectra of residual nuclei after the antiproton absorption. We intend to begin with measurements on selected isotopically pure targets. Strong interaction effects, the antiproton absorption and the atomic cascade are analysed through the measurement of energies, lineshapes, relative and absolute intensities of all observable lines. The experiments are continued to determine st in resolved fine structure levels and in different isotopes of the same element. Coincidence techniques may be applied. All components of the experimental set-up are already existing from previous experiments and we could begin the measurements with any slowly extracted beam of low energy at LEAR.

  12. Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R., E-mail: mgherase@csufresno.edu; Vargas, Andres Felipe

    2017-03-15

    Size measurements of an X-ray beam produced by an integrated polycapillary X-ray lens (PXL) and X-ray tube system were performed by means of a scanning X-ray fluorescence (SXRF) method using three different metallic wires. The beam size was obtained by fitting the SXRF data with the analytical convolution between a Gaussian and a constant functions. For each chemical element in the wire an effective energy was calculated based on the incident X-ray spectrum and its photoelectric cross section. The proposed method can be used to measure the effective X-ray beam size in XRF microscopy studies.

  13. Portable X-ray reflectometer using a low power polychromatic X-ray tube

    International Nuclear Information System (INIS)

    Ohnishi, Tsunemasa; Imashuku, Susumu; Yuge, Koretaka; Kawai, Jun; Shimura, Naomi

    2014-01-01

    We developed a portable X-ray reflectometer which measures energy dispersive X-ray reflectivity using a polychromatic X-rays from a low power (a few watts) X-ray tube and a silicon drift detector. A thin Cu film on silicon substrate using the portable reflectometer was measured. A fringe pattern was shifted due to the change of the X-ray incident angle. The measured peak position of the fringe pattern was satisfactorily agreed with the calculation. (author)

  14. Influence of Polarization of the Incident Beam on Integrated Intensities in X-Ray Energy-Dispersive Diffractometry

    DEFF Research Database (Denmark)

    Olsen, J. Staun; Buras, B.; Jensen, T.

    1978-01-01

    Polarization measurements of the primary X-ray beam produced by thick copper and tungsten anodes are reported and formulas derived for integrated intensities of Bragg reflections in energy-dispersive diffractometry with the polarization of the primary beam taken into account. It was found...

  15. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  16. X ray irradiation of a galaxy by an embedded active nucleus

    International Nuclear Information System (INIS)

    Voit, G.M.

    1990-01-01

    The nuclei of active galaxies radiate a significant fraction of their prodigious luminosities in the x-ray band. These energetic photons penetrate the surrounding galaxy, altering the nature of the matter they encounter. This thesis examines the interactions of X-rays with the three major constituents of a galaxy: stars, gas, and grains. X-rays incident upon a star will heat its outer layers, driving a mass outflow from the stellar surface if the X-ray flux is sufficiently high, but the total mass released from a cluster of X-ray irradiated stars is probably insufficient to fuel the active nucleus. X-rays absorbed in weakly ionized molecular clouds create energetic photo-electrons that directly excite line-emitting transitions of H2 and He. An algorithm given here calculates the excitation yields due to X-ray photoelectrons 100 to 10,000 eV in energy over a range of fractional ionizations. When X-rays irradiate dust grains, the temperatures of the smallest grains fluctuate wildly, heating dramatically during X-ray absorption and cooling rapidly thereafter. IR spectra of X-ray irradiated dust will always turn over shortward of 3 microns, because of evaporative cooling, and will display none of the emission features that come from 3 to 5 A particles, for they will be completely evaporated after just a few X-ray heating events

  17. A theoretical study on the pH dependence of X-ray emission spectra for aqueous acetic acid

    Science.gov (United States)

    Nishida, Naohiro; Tokushima, Takashi; Takahashi, Osamu

    2016-04-01

    We performed theoretical calculations to reproduce the site-selective XES spectra for aqueous acetic acid at the oxygen K-edge. The shape of the experimental XES spectra obtained from aqueous acetic acid drastically changed when the pH value was high. Structure sampling of an aqueous acetic acid cluster model was performed by the ab initio molecular dynamics trajectory. Relative XES peak intensities for the core⿿hole excited state dynamics simulations were calculated using density functional theory. We found that the theoretical XES spectra reproduced well the experimental spectra and that these calculations gave us electronic and molecular structure information about aqueous acetic acid.

  18. On the determination of the spin of the black hole in Cyg X-1 from X-ray reflection spectra

    Science.gov (United States)

    Fabian, A. C.; Wilkins, D. R.; Miller, J. M.; Reis, R. C.; Reynolds, C. S.; Cackett, E. M.; Nowak, M. A.; Pooley, G. G.; Pottschmidt, K.; Sanders, J. S.; Ross, R. R.; Wilms, J.

    2012-07-01

    The spin of Cygnus X-1 is measured by fitting reflection models to Suzaku data covering the energy band 0.9-400 keV. The inner radius of the accretion disc is found to lie within 2 gravitational radii (rg=GM/c2), and a value of ? is obtained for the dimensionless black hole spin. This agrees with recent measurements using the continuum fitting method by Gou et al. and of the broad iron line by Duro et al. The disc inclination is measured at ?, which is consistent with the recent optical measurement of the binary system inclination by Orosz et al. of 27°± 0?8. We pay special attention to the emissivity profile caused by irradiation of the inner disc by the hard power-law source. The X-ray observations and simulations show that the index q of that profile deviates from the commonly used, Newtonian, value of 3 within 3rg, steepening considerably within 2rg, as expected in the strong gravity regime.

  19. Simultaneous structural enhancement of powder diffraction spectra obtained by X-ray, neutron and synchrotron diffraction studies

    International Nuclear Information System (INIS)

    Maichle, J.K.

    1988-01-01

    The novel method for the enhancement of structural data is explained, and is applied for the first time for a simultaneous analysis and evaluation of neutron and synchrotron diffraction data obtained for the superconductor BaPb 0.75 Bi 0.25 O 3 . This substance can be specified in the measured temperature range between 2 K and 310 K to belong to the monoclinic space group I 2/m, and thus is determined to be in a distorted perovskite cell ahead of (a≅b≅√2 a 0 ; c≅2a 0 ). The oxygen octaeders are for the most part tilted around the (x.1/4.1/4)-axis. The simultaneous evaluation of several X-ray diffraction data sets of the high-T c superconductor YBa 2 Cu 3 O 7±z confirms the orthorhombic symmetry with space group P mmm, YBa 2 Cu 3 O 7±z likewise is in a distorted perovskite cell ahead of (a≅b≅a 0 ; c≅3a 0 ). At low temperatures, however, a saddle-shaped distortion of the oxygen group, hitherto believed to be plane, is found in the plane (x.y.0.37). (orig.) [de

  20. On the Determination of the Spin of the Black Hole in Cyg X-1 from X-Ray Reflection Spectra

    Science.gov (United States)

    Fabian, A. C.; Wilkins, D.; Miller, J. M.; Reis, R. C.; Reynolds, C. S.; Cackett, E. M.; Nowak, M. A.; Pooley, G.; Pottschmidt, K.; Sanders, J. S.; hide

    2012-01-01

    The spin of Cygnus X-I is measured by fitting reflection models to Suzaku data covering the energy band 0.9-400 keY. The inner radius of the accretion disc is found to lie within 2 gravitational radii (rg = GM/c(exp 2)) and a value for the dimensionless black hole spin is obtained of 0.97(sup .0.14) (sup -0.02). This agrees with recent measurements using the continuum fitting method by Gou et al. and of the broad iron line by Duro et al. The disc inclination is measured at 23.7(sup +6.7) (sup -5.4) deg. which is consistent with the recent optical measurement of the binary system inclination by Orosz et al of 27+/- 0.8 deg. We pay special attention to the emissivity profile caused by irradiation of the inner disc by the hard power-law source. 1be X-ray observations and simulations show that the index q of that profile deviates from the commonly used, Newtonian, value of 3 within 3r(sub g), steepening considerably within 2r(sub g). as expected in the strong gravity regime.

  1. Experimental study of the X-ray spectra optimization for computed radiography mammography systems; Investigacao experimental da otimizacao do espectro de raios X em sistemas de mamografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Tomal, Alessandra, E-mail: atomal@ifi.unicamp.br [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin; Cunha, Diego M. [Universidade Federal de Uberlandia (UFU), Uberlandia, MG (Brazil). Instituto de Fisica; Nogueira, Maria S. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Gaspar, Fabio [Vigilancia Sanitaria, Campinas, SP (Brazil); Poletti, Martin E. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Departamento de Fisica

    2013-12-15

    Digital mammography is replacing screen-film mammography due to several advantages of digital receptors. The use of Computed Radiography (CR) mammography systems has been considered an alternative to achieve digital images with a low cost. Besides, the optimization of the X-ray spectrum, characterized by the anode/filter combination and tube potential, is an important step in order to improve the image quality with the lower dose to the breast. In this work, we investigated the optimal X-ray spectra using a figure of merit for two mammography equipment: Senographe DMR (General Electric Medical Systems) and Mammomat 3000 Nova (Siemens), both using an image plate Kodak EHR-M2 (Kodak DirectView). A PMMA phantom, simulating breast with thicknesses of 5 cm, was used. The anode/filter combinations evaluated were: Mo/Mo, Mo/Rh, Rh/Rh and Rh/Al for the Senographe system, and Mo/Mo, Mo/Rh, W/Rh for the Mammomat system, for all the intervals of tube potential range from 24 to 35 kVp. Results demonstrate that the higher values of FOM were achieved with the Rh/Rh at 29 kVp and Rh/Al at 26 kVp for the Senographe system, and for the W/Rh at 28 kVp in the Mammomat one. The reduction in the dose associated with the optimum spectra was 13 and 26% for the Senographe and Mammomat systems, respectively. Finally, our results suggest that anode/filter combinations of more energetic spectra than the standard Mo/Mo combination are recommended for thicker breast, in order to reduce the breast dose levels. (author)

  2. Cosmic x ray physics

    Science.gov (United States)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1991-01-01

    The annual progress report on Cosmic X Ray Physics for the period 1 Jan. to 31 Dec. 1990 is presented. Topics studied include: soft x ray background, new sounding rocket payload: x ray calorimeter, and theoretical studies.

  3. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  4. Chest x-ray

    Science.gov (United States)

    Chest radiography; Serial chest x-ray; X-ray - chest ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  5. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  6. Quantitative determination of lateral concentration and depth profile of histidine-tagged recombinant proteins probed by grazing incidence X-ray fluorescence.

    Science.gov (United States)

    Körner, Alexander; Abuillan, Wasim; Deichmann, Christina; Rossetti, Fernanda F; Köhler, Almut; Konovalov, Oleg V; Wedlich, Doris; Tanaka, Motomu

    2013-05-02

    We have demonstrated that the complementary combination of grazing incidence X-ray fluorescence (GIXF) with specular X-ray reflectivity (XRR) can be used to quantitatively determine the density profiles of Ni(2)(+) ions complexed with chelator headgroups as well as S atoms in recombinant proteins anchored to lipid monolayers at the air/water interface. First, we prepared phospholipid monolayers incorporating chelator lipid anchors at different molar fractions at the air/water interface. The fine-structures perpendicular to the global plane of monolayers were characterized by XRR in the presence of Ni(2)(+) ions, yielding the thickness, roughness, and electron density of the stratified lipid monolayers. X-ray fluorescence intensities from Ni Kα core levels recorded at the incidence angles below and above the critical angle of total reflection allow for the determination of the position and lateral density of Ni(2)(+) ions associated with chelator headgroups with a high spatial accuracy (±5 Å). The coupling of histidine-tagged Xenopus cadherin 11 (Xcad-11) can also be identified by changes in the fines-structures using XRR. Although fluorescence intensities from S Kα level were much weaker than Ni Kα signals, we could detect the location of S atoms in recombinant Xcad-11 proteins.

  7. Pair Natural Orbital Restricted Open-Shell Configuration Interaction (PNO-ROCIS) Approach for Calculating X-ray Absorption Spectra of Large Chemical Systems.

    Science.gov (United States)

    Maganas, Dimitrios; DeBeer, Serena; Neese, Frank

    2018-02-08

    In this work, the efficiency of first-principles calculations of X-ray absorption spectra of large chemical systems is drastically improved. The approach is based on the previously developed restricted open-shell configuration interaction singles (ROCIS) method and its parametrized version, based on a density functional theory (DFT) ground-state determinant ROCIS/DFT. The combination of the ROCIS or DFT/ROCIS methods with the well-known machinery of the pair natural orbitals (PNOs) leads to the new PNO-ROCIS and PNO-ROCIS/DFT variants. The PNO-ROCIS method can deliver calculated metal K-, L-, and M-edge XAS spectra orders of magnitude faster than ROCIS while maintaining an accuracy with calculated spectral parameters better than 1% relative to the original ROCIS method (referred to as canonical ROCIS). The method is of a black box character, as it does not require any user adjustments, while it scales quadratically with the system size. It is shown that for large systems, the size of the virtual molecular orbital (MO) space is reduced by more than 90% with respect to the canonical ROCIS method. This allows one to compute the X-ray absorption spectra of a variety of large "real-life" chemical systems featuring hundreds of atoms using a first-principles wave-function-based approach. Examples chosen from the fields of bioinorganic and solid-state chemistry include the Co K-edge XAS spectrum of aquacobalamin [H 2 OCbl] + , the Fe L-edge XAS spectrum of deoxymyoglobin (DMb), the Ti L-edge XAS spectrum of rutile TiO 2 , and the Fe M-edge spectrum of α-Fe 2 O 3 hematite. In the largest calculations presented here, molecules with more than 700 atoms and cluster models with more than 50 metal centers were employed. In all the studied cases, very good to excellent agreement with experiment is obtained. It will be shown that the PNO-ROCIS method provides an unprecedented performance of wave-function-based methods in the field of computational X-ray spectroscopy.

  8. X-ray spectra of B- and Be-like chromium in the 13-15-A region

    Science.gov (United States)

    Burkhalter, P. G.; Charatis, G.; Rockett, P. D.; Newman, D.

    1984-04-01

    Improved spectroscopic techniques have yielded high-resolution L-series spectra for Cr. A focused-laser beam was used to generate the plasma source emission. The spectra, collected in two separate spectrograph settings, were identified with the aid of theoretical atomic-structure calculations as 2p-3d transitions in B- and Be-like Cr XX and XXI. Distinct spectral lines were classified by using isoelectronic sequence plots.

  9. X-rays as a probe of the Universe

    Indian Academy of Sciences (India)

    Table of contents. X-rays as a probe of the Universe · Probing the Universe ….. Flux = sT4 umax = 1011 T (in Kelvin) · History of x-ray astronomy · X-ray Production · X-ray spectra · Celestial sphere as seen by UHURU (1970) · Slide 8 · X-rays from accreting binary systems · Slide 10 · Neutron stars: Black Hole: · Primary X-ray ...

  10. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  11. Inner-shell X-ray line spectra of highly ionized titanium, chromium, iron and nickel and their application to laboratory plasmas

    International Nuclear Information System (INIS)

    Lemen, J.R.; Phillips, K.J.H.; Doschek, G.A.; Cowan, R.D.

    1986-06-01

    The intensities of X-ray lines due to inner-shell 1s-2p transitions in 0 I-, N I-, and C I-like ions of Ti XV-XVII, Cr XVII-XIX, Fe XIX-XXI, and Ni XXI-XXIII, seen in tokamak plasmas are calculated. The lines are assumed to be formed by dielectronic recombination and inner-shell excitation. The dielectronic rates were calculated using a suite of computer programs developed by one of the authors. The inner-shell contribution was estimated by van Regemorter's formula. The present calculations were applied to the problem of radial ion diffusion in tokamaks. Spectra were calculated by integrating along various lines-of-sight to simulate what might be observed by an actual spectrometer viewing a tokamak plasma. A method for determining the diffusion coefficient from tokamak observations is discussed. (author)

  12. Assignment of Pre-Edge Features in the Ru K-Edge X-Ray Absorption Spectra of Organometallic Ruthenium Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Getty, K.; Delgado-Jaime, M.U.; Kennepohl, P.

    2009-05-18

    The nature of the lowest energy bound-state transition in the Ru K-edge X-ray absorption spectra for a series of Grubbs-type ruthenium complexes was investigated. The pre-edge feature was unambiguously assigned as resulting from formally electric dipole forbidden Ru 4d {l_arrow} 1s transitions. The intensities of these transitions are extremely sensitive to the ligand environment and the symmetry of the metal centre. In centrosymmetric complexes the pre-edge is very weak since it is limited by the weak electric quadrupole intensity mechanism. By contrast, upon breaking centrosymmetry, Ru 5p-4d mixing allows for introduction of electric dipole allowed character resulting in a dramatic increase in the pre-edge intensity. The information content of this approach is explored as it relates to complexes of importance in olefin metathesis and its relevance as a tool for the study of reactive intermediates.

  13. X-ray Spectral Measurements of the JMAR High-Power Laser-plasma Source

    Science.gov (United States)

    Whitlock, Robert R.; Dozier, Charles M.; Newman, Daniel A.; Turcu, I. C. Edmond; Gaeta, Celestino J.; Cassidy, Kelly L.; Powers, Michael F.; Kleindolph, Thomas; Morris, James H.; Forber, Richard A.

    2002-10-01

    X-ray spectra of Cu plasmas at the focus of a four-beam, solid-state diode-pumped laser have been recorded. This laser-plasma X-ray source is being developed for JMAR's lithography systems aimed at high- performance semiconductor integrated circuits. The unique simultaneous overlay of the four sub-nanosecond laser beams at 300 Hertz produces a bright, point-plasma X-ray source. PIN diode measurements of the X-ray output indicate that the conversion efficiency (ratio of X-ray emission energy into 2π steradians to incident laser energy) was approximately 9 percent with average X-ray power yields of greater than 10 Watts. Spectra were recorded on calibrated Kodak DEF film in a curved-crystal spectrograph. A KAP crystal (2d = 26.6 Angstroms) was used to disperse the 900 eV to 3000 eV spectral energies onto the film. Preliminary examination of the films indicated the existence of Cu and Cu XX ionization states. Additional spectra as a function of laser input power were also recorded to investigate potential changes in X-ray yields. These films are currently being analyzed. The analysis of the spectra provide absolute line and continuum intensities, and total X-ray output in the measured spectral range.

  14. Study of molecule-metal interfaces by means of the normal incidence X-ray standing wave technique

    International Nuclear Information System (INIS)

    Mercurio, Giuseppe

    2012-01-01

    Functional surfaces based on monolayers of organic molecules are currently subject of an intense research effort due to their applications in molecular electronics, sensing and catalysis. Because of the strong dependence of organic based devices on the local properties of the molecule-metal interface, a direct investigation of the interface chemistry is of paramount importance. In this context, the bonding distance, measured by means of the normal incidence X-ray standing wave technique (NIXSW), provides a direct access to the molecule-metal interactions. At the same time, NIXSW adsorption heights are used to benchmark different density functional theory (DFT) schemes and determine the ones with predictive power for similar systems. This work investigates the geometric and chemical properties of different molecule/metal interfaces, relevant to molecular electronics and functional surfaces applications, primarily by means of the NIXSW technique. All NIXSW data are analyzed with the newly developed open source program Torricelli, which is thoroughly documented in the thesis. In order to elucidate the role played by the substrate within molecule/metal interfaces, the prototype organic molecule 3,4,9,10-perylene-tetracarboxylic-dianhydride (PTCDA) is explored on the Ag(110) surface. The molecule results more distorted and at smaller bonding distances on the more reactive Ag(110) surface, in comparison with the Ag(100), the Ag(111) and Au(111) substrates. This conclusion follows from the detailed molecular adsorption geometry obtained from the differential analysis of nonequivalent carbon and oxygen species (including a careful error analysis). Subsequently, the chemisorptive PTCDA/Ag(110) interaction is tuned by the co-deposition of an external alkali metal, namely K. As a consequence, the functional groups of PTCDA unbind from the surface, which, in turn, undergoes major reconstruction. In fact, the resulting nanopatterned surface consists of alternated up and down

  15. Interpretation of polarized Cu K x-ray absorption near-edge-structure spectra of CuO

    Czech Academy of Sciences Publication Activity Database

    Šipr, Ondřej; Šimůnek, Antonín

    2001-01-01

    Roč. 13, - (2001), s. 8519-8525 ISSN 0953-8984 Institutional research plan: CEZ:AV0Z1010914 Keywords : polarized Cu K-edge spectra * CuO * band-structure calculations Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.611, year: 2001

  16. Grazing incidence diffraction and X-ray reflectivity studies of the interactions of inorganic mercury salts with membrane lipids in Langmuir monolayers at the air/water interface.

    Science.gov (United States)

    Broniatowski, Marcin; Flasiński, Michał; Dynarowicz-Łatka, Patrycja; Majewski, Jarosław

    2010-07-29

    The interactions of mercury ions with the membrane phospholipids are considered to be of great importance regarding the toxicity of this metal in living organisms. To obtain deeper insight into this problem, we performed systematic studies applying the Langmuir technique complemented with synchrotron X-ray scattering methods (grazing incidence X-ray diffraction (GIXD) and X-ray reflectivity (XR)). We focused our attention on the interactions of inorganic mercury salts dissolved in the aqueous subphase with lipid monolayers, formed by selected membrane phospholipids, namely, dipalmitoylphosphatidylglicerol (DPPG), dipalmitoylphosphatidylcholine (DPPC), 1-octadecyl 2-sn-phosphatidylcholine (lyso-PC), and sphingomyelin (SM). Two different inorganic mercury salts, one of a hydracid, HgCl(2), and the other of an oxacid, Hg(NO(3))(2), have been investigated. Our results proved that the elastic properties of phospholipid monolayers are a key factor regarding the interactions with mercury ions. Significant differences in mercury ions complexation are observed with double-chain phospholipids (such as DPPG and DPPC) forming fluid layers of low compressibility and phospholipids forming more compressible films (like SM and lyso-PC). Namely, important changes in the monolayer characteristic were observed only for the latter kind of lipids. This is an important finding taking into account the accumulation of mercury in the central nervous system and its neurotoxic effects. SM is one of the most abundant lipids in neurons shells and therefore can be considered as a target lipid complexing mercury ions.

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  18. EX56a study of extended X-ray emission around isolated galaxies EX56b identification and spectra of bright X-ray sources at high galactic latitude

    Science.gov (United States)

    Schwartz, Daniel A.

    1987-01-01

    The EXOSAT observations confirmed the identification and extended nature of PKS 2345-35. It gave a good 2 to 10 keV X-ray spectrum and a detailed spatial profile indicating asymmetry of the structure. In the high galactic latitidue investigation, the BL Lac object identified with the HEAO-1 source 1430+423 was detected, and the first X-ray spectrum was obtained. Several simulataneous observations of H0323+022 were obtained over a broad range of electromagnetic spectrum. Studies of luminous active galactic nuclei have given significant information on the spectrum of the quasar PKS 0558-504. In a study of Southern sky cataclysmic variables, the EXOSAT was used to determine the X-ray spectrum and search for periodicities in two objects. Studies of complete identifications have revealed that X-ray sources in two high galactic latitude fields are stars, and therefore are to be excluded from the Piccinotti extragalactic sample. Only one Piccinotti source remains to be identified.

  19. Element-specific gap in the p states for ternary semiconductors CuGaSe.sub.2./sub. and ZnGeAs.sub.2./sub. via alignment of x-ray emission and x-ray absorption spectra

    Czech Academy of Sciences Publication Activity Database

    Drahokoupil, Jiří; Šipr, Ondřej; Šimůnek, Antonín

    2008-01-01

    Roč. 20, č. 15 (2008), 155206/1-155206/6 ISSN 0953-8984 R&D Projects: GA AV ČR IAA100100514 Institutional research plan: CEZ:AV0Z10100521 Keywords : x-ray spectroscopy * energy gap * scissor operator Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.900, year: 2008

  20. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  1. A customizable software for fast reduction and analysis of large X-ray scattering data sets: applications of the new DPDAK package to small-angle X-ray scattering and grazing-incidence small-angle X-ray scattering.

    Science.gov (United States)

    Benecke, Gunthard; Wagermaier, Wolfgang; Li, Chenghao; Schwartzkopf, Matthias; Flucke, Gero; Hoerth, Rebecca; Zizak, Ivo; Burghammer, Manfred; Metwalli, Ezzeldin; Müller-Buschbaum, Peter; Trebbin, Martin; Förster, Stephan; Paris, Oskar; Roth, Stephan V; Fratzl, Peter

    2014-10-01

    X-ray scattering experiments at synchrotron sources are characterized by large and constantly increasing amounts of data. The great number of files generated during a synchrotron experiment is often a limiting factor in the analysis of the data, since appropriate software is rarely available to perform fast and tailored data processing. Furthermore, it is often necessary to perform online data reduction and analysis during the experiment in order to interactively optimize experimental design. This article presents an open-source software package developed to process large amounts of data from synchrotron scattering experiments. These data reduction processes involve calibration and correction of raw data, one- or two-dimensional integration, as well as fitting and further analysis of the data, including the extraction of certain parameters. The software, DPDAK (directly programmable data analysis kit), is based on a plug-in structure and allows individual extension in accordance with the requirements of the user. The article demonstrates the use of DPDAK for on- and offline analysis of scanning small-angle X-ray scattering (SAXS) data on biological samples and microfluidic systems, as well as for a comprehensive analysis of grazing-incidence SAXS data. In addition to a comparison with existing software packages, the structure of DPDAK and the possibilities and limitations are discussed.

  2. Comparison of various molecular forms of bovine trypsin: Correlation of infrared spectra with X-ray crystal structures

    Energy Technology Data Exchange (ETDEWEB)

    Prestrelski, S.J. (Mount Sinai School of Medicine of the City Univ. of New York (USA)); Byler, D.M. (U.S. Department of Agriculture, Philadelphia, PA (USA)); Liebman, M.N. (AMOCO Technology Corporation, Naperville, IL (USA))

    1991-01-01

    Fourier-transform infrared spectroscopy is a valuable method for the study of protein conformation in solution primarily because of the sensitivity to conformation of the amide I band (1700-1620 cm{sup {minus}1}) which arises from the backbone C{double bond}O stretching vibration. Combined with resolution-enhancement techniques such as derivative spectroscopy and self-deconvolution, plus the application of iterative curve-fitting techniques, this method provides a wealth of information concerning protein secondary structure. Further extraction of conformational information from the amide I band is dependent upon discerning the correlations between specific conformation types and component bands in the amide I region. In this paper the authors report spectra-structure correlations derived from conformational perturbations in bovine trypsin which arise from autolytic processing, zymogen activation, and active-site inhibition. IR spectra were collected for the single-chain ({beta}-trypsin) and once-cleaved, double-chain ({alpha}-trypsin) forms as well as at various times during the course of autolysis and also for zymogen, trypsinogen, and {beta}-trypsin inhibited with diisopropyl fluorophosphate. Spectral differences among the various molecular forms were interpreted in light of previous biochemical studies of autolysis and the known three-dimensional structures of the zymogen, the active enzyme, and the DIP-inhibited form. The spectroscopic results from these proteins in D{sub 2}O imply that certain loop structures may absorb in the region of 1655 cm{sup {minus}1}. They estimate that this approach to data analysis and interpretation is sensitive to changes of 0.01 unit or less in the relative integrated intensities of component bands in spectra whose peaks are well resolved.

  3. Friction behaviour of TiAlN films around cubic/hexagonal transition: A 2D grazing incidence X-ray diffraction and electron energy loss spectroscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Pinot, Y. [Université de Haute Alsace, Laboratoire Physique et Mécanique Textiles (EA 4365), F-68093 Mulhouse (France); Pac, M.-J., E-mail: marie-jose.pac@uha.fr [Université de Haute Alsace, Laboratoire Physique et Mécanique Textiles (EA 4365), F-68093 Mulhouse (France); Henry, P. [Université de Haute Alsace, Laboratoire Physique et Mécanique Textiles (EA 4365), F-68093 Mulhouse (France); Rousselot, C. [Université de Franche-Comté, FEMTO-ST (UMR CNRS 6174), F-25211 Montbéliard (France); Odarchenko, Ya.I.; Ivanov, D.A. [Université de Haute Alsace, Institut de Science des Matériaux de Mulhouse (UMR 7361 CNRS), F-68093 Mulhouse (France); Ulhaq-Bouillet, C.; Ersen, O. [Université de Strasbourg, Institut de Physique et Chimie des Matériaux de Strasbourg (UMR CNRS 7504), F-67087 Strasbourg (France); Tuilier, M.-H. [Université de Haute Alsace, Laboratoire Physique et Mécanique Textiles (EA 4365), F-68093 Mulhouse (France)

    2015-02-27

    The properties at different scales of Ti{sub 1−x}Al{sub x}N films deposited by reactive magnetron sputtering from TiAl sintered (S) targets produced by powder metallurgy are compared with those of a set of films previously deposited in the same conditions from mosaic targets (M) made of pure Ti and Al metals. For compositions close to the hcp/fcc transition (around x = 0.6), the friction behaviour, growth directions and organization of crystallized domains are found to be sensitive to the type of target used. The resistance to crack creation is higher for Ti{sub 0.54}Al{sub 0.46}N (S) and Ti{sub 0.38}Al{sub 0.62}N (S) than for Ti{sub 0.50}Al{sub 0.50}N (M) and Ti{sub 0.32}Al{sub 0.68}N (M). From the measurement of mechanical properties, toughness, and wear volumes and from the observation of wear tracks, it is found that films prepared from sintered targets exhibit a better wear resistance. Grazing incidence X-ray diffraction and electron energy loss spectroscopy in Transmission Electronic Microscopy are used to investigate the long- and short-range orders within the films. The morphology of Ti{sub 0.54}Al{sub 0.46}N (S) film can be considered as an array of crystalline domains having reciprocal-space vectors 111 and 200 directed along the meridian but with random in-plane orientation. Ti{sub 0.38}Al{sub 0.62}N (S) Al-rich film presents a random orientation of the crystalline domains whereas Ti{sub 0.32}Al{sub 0.68}N (M) deposited from composite targets exhibits a well-oriented fibrillar structure. The N K-edge Electron Energy Loss Near Edge Spectra are discussed with previous results of Extended X-ray Absorption Fine Structure Spectroscopy, which has evidenced different values of Al–N and Ti–N bond lengths, either octahedral (cubic-like) or tetrahedral (hexagonal-like) within Ti{sub 0.50}Al{sub 0.50}N (M) and Ti{sub 0.32}Al{sub 0.68}N (M) films. For similar compositions, films deposited from sintered alloys contain more nitrogen atoms in octahedral cubic

  4. Spectroscopic Studies of X-Ray Binary Pulsars

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    X-ray spectra of black hole binaries and active galactic nuclei show a non- thermal power law spectra extended over wide energy range toward hard X-rays to γ-rays. In contrast to these X-ray sources, XBPs fundamentally show a power law spectra with photon indices 1–2 with high-energy turnover at relatively low energies.

  5. Parallel of semi-empirical results simulated by MCNP of X-ray spectra with a semiconductor; Paralelo de resultado semi- empiricos simulados por MCNPX de espectros de raios-X com um semicondutor

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L.R.; Vivolo, V.; Potiens, M.P.A., E-mail: dossantos.lucasrodrigues@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Navarro, M.V.T.; Santos, W.S. [Universidade Federal de Uberlandia (INFIS/UFU), MG (Brazil). Instituto de Fisica

    2016-07-01

    The aim of this study was to use the MCNPX radiation transport code to simulate X-ray spectra generated by a constant voltage system in a CdTe semiconductor detector. As part of the validation process, we obtained a series of experimental spectra. Comparatively, in all cases there is a good correlation between the two spectra. There were no statistically significant differences between the experimental results with the simulated. (author)

  6. Arrangement for X-ray shield

    International Nuclear Information System (INIS)

    1980-01-01

    X-ray screen unit consisting of a light transmissive carrier onto which scintillation material is deposited, which is able to generate light under the influence of incident X-ray irradiation, characterised in that the X-ray screen comprises a number of sectors, wherein the surface with respect to the incident X-radiation is maintained at an acute angle. (G.C.)

  7. Isolated elliptically polarized attosecond soft X-ray with high-brilliance using polarization gating of harmonics from relativistic plasmas at oblique incidence.

    Science.gov (United States)

    Chen, Zi-Yu; Li, Xiao-Ya; Li, Bo-Yuan; Chen, Min; Liu, Feng

    2018-02-19

    The production of intense isolated attosecond pulse is a major goal in ultrafast research. Recent advances in high harmonic generation from relativistic plasma mirrors under oblique incidence interactions gave rise to photon-rich attosecond pulses with circular or elliptical polarization. However, to achieve an isolated elliptical attosecond pulse via polarization gating using currently available long driving pulses remains a challenge, because polarization gating of high harmonics from relativistic plasmas is assumed only possible at normal or near-normal incidence. Here we numerically demonstrate a scheme around this problem. We show that via control of plasma dynamics by managing laser polarization, it is possible to gate an intense single attosecond pulse with high ellipticity extending to the soft X-ray regime at oblique incidence. This approach thus paves the way towards a powerful tool enabling high-time-resolution probe of dynamics of chiral systems and magnetic materials with current laser technology.

  8. Correlations Between Variations in Solar EUV and Soft X-Ray Irradiance and Photoelectron Energy Spectra Observed on Mars and Earth

    Science.gov (United States)

    Peterson, W. K.; Brain, D. A.; Mitchell, D. L.; Bailey, S. M.; Chamberlin, P. C.

    2013-01-01

    Solar extreme ultraviolet (EUV; 10-120 nm) and soft X-ray (XUV; 0-10 nm) radiation are major heat sources for the Mars thermosphere as well as the primary source of ionization that creates the ionosphere. In investigations of Mars thermospheric chemistry and dynamics, solar irradiance models are used to account for variations in this radiation. Because of limited proxies, irradiance models do a poor job of tracking the significant variations in irradiance intensity in the EUV and XUV ranges over solar rotation time scales when the Mars-Sun-Earth angle is large. Recent results from Earth observations show that variations in photoelectron energy spectra are useful monitors of EUV and XUV irradiance variability. Here we investigate photoelectron energy spectra observed by the Mars Global Surveyor (MGS) Electron Reflectometer (ER) and the FAST satellite during the interval in 2005 when Earth, Mars, and the Sun were aligned. The Earth photoelectron data in selected bands correlate well with calculations based on 1 nm resolution observations above 27 nm supplemented by broadband observations and a solar model in the 0-27 nm range. At Mars, we find that instrumental and orbital limitations to the identifications of photoelectron energy spectra in MGS/ER data preclude their use as a monitor of solar EUV and XUV variability. However, observations with higher temporal and energy resolution obtained at lower altitudes on Mars might allow the separation of the solar wind and ionospheric components of electron energy spectra so that they could be used as reliable monitors of variations in solar EUV and XUV irradiance than the time shifted, Earth-based, F(10.7) index currently used.

  9. Discrimination and quantification of contamination and implanted solar wind in Genesis collector shards using grazing incidence synchrotron x-ray techniques: Initial results

    International Nuclear Information System (INIS)

    Kitts, K.; Sutton, S.; Eng, P.; Ghose, S.; Burnett, D.

    2006-01-01

    Grazing incidence X-ray fluorescence is a non-destructive technique that can differentiate the embedded solar wind component from surface contamination and collector background in the Genesis shards. Initial solar Fe abundance in D30554 is 8 x 10 12 /cm 2 . Accurate knowledge of the composition of the Sun provides a baseline, which allows an understanding of how the solar system has evolved over time and how solar processes and solar wind mechanics behave. Unfortunately, the errors in photospheric abundances are too large for many planetary science problems and this hampers our understanding of these different processes. Analyses of solar wind implanted in meteorites or lunar soils have provided more precise data but alteration processes on these bodies may complicate such information. In response to this need for pristine solar wind samples, NASA developed and launched the Genesis Probe. Unfortunately, the probe smashed into the Utah desert shattering the 300 collector plates into 15,000+ pieces all of which are now coated in a both a fine terrestrial dust and Si and Ge powder from the disrupted collectors themselves. The solar wind penetration depth is 100-200 nm and the superposed contamination layers are typically 40-50 nm. Stringent cleaning regimes have the potential of removing the solar wind itself. The best solution is to have sufficient spatial resolution to separately analyze the surface contamination and penetrated solar wind. To that end, three Genesis collector array shards and their appropriate flight spares were characterized via grazing incidence x-ray fluorescence and x-ray reflectivity. The goals were (1) to evaluate the various cleaning methods used to eliminate contamination, (2) to identify the collector substrates most suited for this technique, (3) to determine whether the solar wind signature could be deconvolved from the collector background signature, and (4) to measure the relative abundances of Ca to Ge in the embedded solar wind.

  10. X-ray tube

    International Nuclear Information System (INIS)

    Mayo, B.J.

    1980-01-01

    An x-ray tube in which the x-ray origin is scanned on a circle around the patient, comprises a ring-shaped anode, an electron beam travelling along a circular path being deflected onto the anode at the desired positions. The electron beam path may be in a plane parallel to the anode and perhaps at the same radius. It may be in the same plane as a transmission target/anode and at a greater radius. The anode should extend over at least 180 0 although it may extend to 360 0 . Electrostatic means may be provided to constrain the beam to the circular path and further electrostatic means deflect it to the anode of the beam and ensure it is focused at the point of incidence. Collimators provide a planar fan-shaped beam and the anode may be shaped to attenuate side lobes of the radiation. Electrode collects electrons not deflected. The focal regions may be adjacent or otherwise. Coils may provide periodic focusing to overcome space charge dispersion and dynamic adjustment of the focusing before deflection ensures focusing at target incidence. Focusing may be absent near the deflection region, and current in the coil section near the focal region should be zero. (author)

  11. Characterisation of corrosion deposits induced by carbon dioxide on mild steel using grazing incidence x-ray and synchrotron radiation diffraction

    International Nuclear Information System (INIS)

    Sembiring, S.; O'Connor, B; Li, D.; Buckley, C.; Van Riessen, A.; De Marco, R.

    1999-01-01

    Full text: Grazing incidence diffraction, using x-rays (GIXRD) and synchrotron radiation (GISRD), is being applied for near-surface characterisation of corrosion deposits formed on the internal surfaces of mild steel pipelines which are used to deliver natural gas from offshore deposits in Western Australia. These techniques are being employed to construct phase composition depth-profiles of corrosion product phases. The GIXRD data are being measured with CuKα radiation using a Siemens D5000 x-ray diffractometer, fitted with a primary beam slit system for incidence angle control and also with a diffracted beam monochromator; and the GISRD data have been acquired with the BIGDIFF instrument on the ANBF beamline in Tsukuba, Japan. The mild steel test samples are prepared with a laboratory reactor in which the corrosion conditions are simulated in a controlled manner. Results obtained to date have shown that two phases are readily observed in addition to the a-Fe phase from the mild steel substrate: (1) FeCO 3 (siderite) induced by CO 2 dissolved in the water flowing through the pipeline, and (2) CaCO 3 (calcite) deposited on the mild steel surface by reaction between the CO 2 and calcium ions which are also present in the water flowing through the pipeline. Supporting measurements from SEM imaging and associated EDS analysis will also be presented

  12. Investigating Polymer–Metal Interfaces by Grazing Incidence Small-Angle X-Ray Scattering from Gradients to Real-Time Studies

    Directory of Open Access Journals (Sweden)

    Matthias Schwartzkopf

    2016-12-01

    Full Text Available Tailoring the polymer–metal interface is crucial for advanced material design. Vacuum deposition methods for metal layer coating are widely used in industry and research. They allow for installing a variety of nanostructures, often making use of the selective interaction of the metal atoms with the underlying polymer thin film. The polymer thin film may eventually be nanostructured, too, in order to create a hierarchy in length scales. Grazing incidence X-ray scattering is an advanced method to characterize and investigate polymer–metal interfaces. Being non-destructive and yielding statistically relevant results, it allows for deducing the detailed polymer–metal interaction. We review the use of grazing incidence X-ray scattering to elucidate the polymer–metal interface, making use of the modern synchrotron radiation facilities, allowing for very local studies via in situ (so-called “stop-sputter” experiments as well as studies observing the nanostructured metal nanoparticle layer growth in real time.

  13. Determination of half value layer and applied voltage from emitted spectra by an X-ray tube; Determinacao da camada semirredutora e da tensao aplicada a partir de espectros emitidos por um tubo de raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Josilene C.; Gonzales, Alejandro H.L.; Terini, Ricardo A.; Costa, Paulo R., E-mail: josilene@usp.br [Universidade de Sao Paulo (USP), SP (Brazil). Instituto de Fisica

    2016-07-01

    This work describes a method for assessment of half value layer (HVL) and peak tube voltage (kVp) applied in an X-ray tube by means of experimental X-ray spectra measured using a CdTe detector. It was assessed some parameters that can affect the evaluation of these quantities such as dead time, count rate and tube current (mA). For this study, two sets of X-ray spectra were measured: Set A), spectra measurements using Cu filters with different thicknesses (1.8 - 5.4 mm) and fixed tube current; Set B), spectra measurements keeping a fixed Cu filtration and varying tube current (0.5 - 3.0 mA). The experimental setup for the Set A spectra measurements allowed the assessment of the HVL and kVp for different count rates and dead time in the detection system, while the Set B setup allowed to assess the dependence of these quantities with the tube current. The spectrometer was energy calibrated using standard X/γ rays radioactive sources. The tube voltage values were estimated by means of experimental measured X-ray spectra, using linear regression in order to search the end point of each spectrum. The spectra correction was performed using the stripping procedure developed for the Matlab® software and the HVL values were derived from these corrected spectra. For comparison, HVL was also determined using a 30 cm{sup 3} ion chamber and high purity Al filters. The results show that it is possible to determine the kVp with accuracy and reproducibility using spectra with dead time of up to 10%. In spite of this, the values obtained showed a deviation of up to 7 kV, for spectra measured using the same nominal tube voltage different tube current values, indicating dependence between these two parameters. (author)

  14. Microfocussing of synchrotron X-rays using X-ray refractive lens ...

    Indian Academy of Sciences (India)

    2014-07-02

    Jul 2, 2014 ... ring (black) is fixed from polyimide side and (g) finally the metal substrate is etched to prepare the X-ray mask. standardized for the present X-ray lithography beamline. X-ray exposures are carried out in 3–10 keV region selected using two X-ray mirrors kept at grazing incidence angles. The total power ...

  15. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  16. Core-level spectra and binding energies of transition metal nitrides by non-destructive x-ray photoelectron spectroscopy through capping layers

    Science.gov (United States)

    Greczynski, G.; Primetzhofer, D.; Lu, J.; Hultman, L.

    2017-02-01

    We present the first measurements of x-ray photoelectron spectroscopy (XPS) core level binding energies (BE:s) for the widely-applicable group IVb-VIb polycrystalline transition metal nitrides (TMN's) TiN, VN, CrN, ZrN, NbN, MoN, HfN, TaN, and WN as well as AlN and SiN, which are common components in the TMN-based alloy systems. Nitride thin film samples were grown at 400 °C by reactive dc magnetron sputtering from elemental targets in Ar/N2 atmosphere. For XPS measurements, layers are either (i) Ar+ ion-etched to remove surface oxides resulting from the air exposure during sample transfer from the growth chamber into the XPS system, or (ii) in situ capped with a few nm thick Cr or W overlayers in the deposition system prior to air-exposure and loading into the XPS instrument. Film elemental composition and phase content is thoroughly characterized with time-of-flight elastic recoil detection analysis (ToF-E ERDA), Rutherford backscattering spectrometry (RBS), and x-ray diffraction. High energy resolution core level XPS spectra acquired with monochromatic Al Kα radiation on the ISO-calibrated instrument reveal that even mild etching conditions result in the formation of a nitrogen-deficient surface layer that substantially affects the extracted binding energy values. These spectra-modifying effects of Ar+ ion bombardment increase with increasing the metal atom mass due to an increasing nitrogen-to-metal sputter yield ratio. The superior quality of the XPS spectra obtained in a non-destructive way from capped TMN films is evident from that numerous metal peaks, including Ti 2p, V 2p, Zr 3d, and Hf 4f, exhibit pronounced satellite features, in agreement with previously published spectra from layers grown and analyzed in situ. In addition, the N/metal concentration ratios are found to be 25-90% higher than those obtained from the corresponding ion-etched surfaces, and in most cases agree very well with the RBS and ToF-E ERDA values. The N 1 s BE:s extracted from

  17. Core-level spectra and binding energies of transition metal nitrides by non-destructive x-ray photoelectron spectroscopy through capping layers

    Energy Technology Data Exchange (ETDEWEB)

    Greczynski, G., E-mail: grzgr@ifm.liu.se [Thin Film Physics Division, Department of Physics (IFM), Linköping University, SE-581 83 Linköping (Sweden); Primetzhofer, D. [Department of Physics and Astronomy, The Ångström Laboratory, Uppsala University, P.O. Box 516, SE-751 20 Uppsala (Sweden); Lu, J.; Hultman, L. [Thin Film Physics Division, Department of Physics (IFM), Linköping University, SE-581 83 Linköping (Sweden)

    2017-02-28

    Highlights: • First non-destructive measurements of XPS core level binding energies for group IVb-VIb transition metal nitrides are presented. • All films are grown under the same conditions and analyzed in the same instrument, providing a useful reference for future XPS studies. • Extracted core level BE values are more reliable than those obtained from sputter-cleaned N-deficient surfaces. • Comparison to Ar+-etched surfaces reveals that even mild etching conditions result in the formation of a nitrogen-deficient surface layer. • The N/metal concentration ratios from capped samples are found to be 25-90% higher than those from the corresponding ion-etched surfaces. - Abstract: We present the first measurements of x-ray photoelectron spectroscopy (XPS) core level binding energies (BE:s) for the widely-applicable group IVb-VIb polycrystalline transition metal nitrides (TMN’s) TiN, VN, CrN, ZrN, NbN, MoN, HfN, TaN, and WN as well as AlN and SiN, which are common components in the TMN-based alloy systems. Nitride thin film samples were grown at 400 °C by reactive dc magnetron sputtering from elemental targets in Ar/N{sub 2} atmosphere. For XPS measurements, layers are either (i) Ar{sup +} ion-etched to remove surface oxides resulting from the air exposure during sample transfer from the growth chamber into the XPS system, or (ii) in situ capped with a few nm thick Cr or W overlayers in the deposition system prior to air-exposure and loading into the XPS instrument. Film elemental composition and phase content is thoroughly characterized with time-of-flight elastic recoil detection analysis (ToF-E ERDA), Rutherford backscattering spectrometry (RBS), and x-ray diffraction. High energy resolution core level XPS spectra acquired with monochromatic Al Kα radiation on the ISO-calibrated instrument reveal that even mild etching conditions result in the formation of a nitrogen-deficient surface layer that substantially affects the extracted binding energy

  18. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  19. High resolution X ray spectroscopy

    International Nuclear Information System (INIS)

    Bartiromo, R.

    1987-01-01

    This paper is devoted to a detailed discussion of the physical processes which are responsible for the emission spectra of H-like and He-like ion of high Z impurities in low density plasmas. The application of high resolution X-ray spectroscopy to the diagnostic of tokamak plasmas is also discussed and examples of the results obtained are presented

  20. X ray imaging microscope for cancer research

    Science.gov (United States)

    Hoover, Richard B.; Shealy, David L.; Brinkley, B. R.; Baker, Phillip C.; Barbee, Troy W., Jr.; Walker, Arthur B. C., Jr.

    1991-01-01

    The NASA technology employed during the Stanford MSFC LLNL Rocket X Ray Spectroheliograph flight established that doubly reflecting, normal incidence multilayer optics can be designed, fabricated, and used for high resolution x ray imaging of the Sun. Technology developed as part of the MSFC X Ray Microscope program, showed that high quality, high resolution multilayer x ray imaging microscopes are feasible. Using technology developed at Stanford University and at the DOE Lawrence Livermore National Laboratory (LLNL), Troy W. Barbee, Jr. has fabricated multilayer coatings with near theoretical reflectivities and perfect bandpass matching for a new rocket borne solar observatory, the Multi-Spectral Solar Telescope Array (MSSTA). Advanced Flow Polishing has provided multilayer mirror substrates with sub-angstrom (rms) smoothnesss for the astronomical x ray telescopes and x ray microscopes. The combination of these important technological advancements has paved the way for the development of a Water Window Imaging X Ray Microscope for cancer research.

  1. Determination of semi-reducing layer and applied stress through spectra emitted by an X-ray tube; Determinacao da camada semirredutora e da tensao aplicada atraves de espectros emitidos por um tubo de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Josilene C.; Gonzalez, Alejandro H.L.; Terini, Ricardo A.; Costa, Paulo R. [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-07-01

    This work describes a method for assessment of half value layer (HVL) and peak tube voltage (kVp) by means of experimental x-ray spectra measured using a CdTe detector. The work also evaluated spectrometry parameters such as dead time and count rate, and x-ray tube characteristics that can affect the assessment of these quantities. Two sets of x-ray spectra were measured: A) using Cu filters with different thicknesses and fixed tube current, and B) keeping a fixed Cu filtration and different tube current and, so, ranging the count rates. The spectrometer was energy calibrated using standard radioactive sources. kVp value was estimated by means of experimental measured x-ray spectra, using linear regression in order to search the end point of each spectrum. HVL was estimated after the correction of the measured spectra, using an analytical method implemented using Matlab® software. For comparison, HVL was also determined using a 30 cm{sup 3} ion chamber and high purity Al filters. (author)

  2. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  3. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  4. Dental x-rays

    Science.gov (United States)

    X-ray - teeth; Radiograph - dental; Bitewings; Periapical film; Panoramic film; Digital image ... dentist's office. There are many types of dental x-rays. Some of them are: Bitewing. Shows the crown ...

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  6. X-ray (image)

    Science.gov (United States)

    X-rays are a form of ionizing radiation that can penetrate the body to form an image on ... will be shades of gray depending on density. X-rays can provide information about obstructions, tumors, and other ...

  7. A versatile three/four crystal X-ray diffractometer for X-ray optical elements: Performance and applications

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Jacobsen, E.

    1987-01-01

    A versatile X-ray diffractometer for the study of X-ray optical elements such as grazing incidence mirrors, crystals and X-ray gratings has been built and put into operation at the Danish Space Research Institute. The diffractrometer is built on a 1.5 m long granite bench with the X-ray source...

  8. Classification of X-ray spectra from laser produced plasmas of atoms from Tm to Pt in the range 6-9A

    International Nuclear Information System (INIS)

    Mandelbaum, P.; Klapisch, M.; Bar-Shalom, A.; Schwob, J.L.; Zigler, A.

    1983-01-01

    X-ray spectra of highly ionized tungsten and neighbouring atoms (Tm, Yb, Hf, Ta, W, Re and Pt) has been observed from laser produced plasmas in the lambda = 6-9A range. Beside the prominent lines of the Ni I-like ions, lines belonging to Co I (3d 9 -3d 8 4p), Cu I (3d 10 4s-3d 9 4s4p, 3d 10 4p-3d 9 4p 2 ) and Zn I-like ions (3d 10 4s 2 -3d 9 4s 2 4p, 3d 10 4s4p-3d 9 4s4p 2 ) have been identified. Classification was based on isoelectronic sequence analysis and on comparison with ab-initio relativistic calculations. A collisional-radiative model of the Cu I-like ions in the plasma is used to show that the contribution of the 3d 10 4d-3d 9 4p4d and 3d 10 4f-3d 9 4f4p transition arrays to the 3d-4p spectrum is small. The importance of configuration interaction is pointed out. Computations agree with measurements within experimental uncertainty. (Auth.)

  9. How calibration and reference spectra affect the accuracy of absolute soft X-ray solar irradiance measured by the SDO/EVE/ESP during high solar activity

    Science.gov (United States)

    Didkovsky, Leonid; Wieman, Seth; Woods, Thomas

    2016-10-01

    The Extreme ultraviolet Spectrophotometer (ESP), one of the channels of SDO's Extreme ultraviolet Variability Experiment (EVE), measures solar irradiance in several EUV and soft x-ray (SXR) bands isolated using thin-film filters and a transmission diffraction grating, and includes a quad-diode detector positioned at the grating zeroth-order to observe in a wavelength band from about 0.1 to 7.0 nm. The quad diode signal also includes some contribution from shorter wavelength in the grating's first-order and the ratio of zeroth-order to first-order signal depends on both source geometry, and spectral distribution. For example, radiometric calibration of the ESP zeroth-order at the NIST SURF BL-2 with a near-parallel beam provides a different zeroth-to-first-order ratio than modeled for solar observations. The relative influence of "uncalibrated" first-order irradiance during solar observations is a function of the solar spectral irradiance and the locations of large Active Regions or solar flares. We discuss how the "uncalibrated" first-order "solar" component and the use of variable solar reference spectra affect determination of absolute SXR irradiance which currently may be significantly overestimated during high solar activity.

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  11. Resonant X-ray emission spectroscopy in Dy compounds

    International Nuclear Information System (INIS)

    Tanaka, Satoshi; Okada, Kozo; Kotani, Akio.

    1994-01-01

    The excitation spectrum of the L 3 -M 5 X-ray emission of Dy compounds in the pre-edge region of Dy L 3 X-ray absorption near edge structure (L 3 -XANES) is theoretically investigated based upon the coherent second order optical formula with multiplet coupling effects. The spectral broadening of the excitation spectrum is determined by the M 5 core hole lifetime, being free from the L 3 core hole lifetime. The fine pre-edge structure of the L 3 edge due to the 2p→4f quadrupole transition can be seen in the excitation spectrum, while this structure is invisible in the conventional XANES, in agreement with the recent experimental results. We clarify the conditions for the excitation spectrum to be regarded as the absorption spectrum with a smaller width. The resonant X-ray emission spectra for various incident photon energies around the L 3 edge are also calculated. (author)

  12. A deep X-ray view of the bare AGN Ark120. IV. XMM-Newton and NuSTAR spectra dominated by two temperature (warm, hot) Comptonization processes

    DEFF Research Database (Denmark)

    Porquet, D.; Reeves, J. N.; Matt, G.

    2018-01-01

    an extensive campaign observing Ark 120 in X-rays with XMM-Newton (4 × 120 ks, 2014 March 18–24), and NuSTAR (65.5 ks, 2014 March 22).Results. During this very deep X-ray campaign, the source was caught in a high-flux state similar to the earlier 2003 XMM-Newton observation, and about twice as bright...... as the lower-flux observation in 2013. The spectral analysis confirms the “softer when brighter” behavior of Ark 120. The four XMM-Newton/pn spectra are characterized by the presence of a prominent soft X-ray excess and a significant Fe Kα complex. The continuum is very similar above about 3 keV, while...

  13. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  14. Depth dependence of the structural phase transition of SrTiO3 studied with β-NMR and grazing incidence x-ray diffraction

    Science.gov (United States)

    Salman, Z.; Smadella, M.; Macfarlane, W. A.; Patterson, B. D.; Willmott, P. R.; Chow, K. H.; Hossain, M. D.; Saadaoui, H.; Wang, D.; Kiefl, R. F.

    2011-06-01

    We present an investigation of the near-surface tetragonal phase transition in SrTiO3, using the complementary techniques of beta-detected nuclear magnetic resonance and grazing-incidence X-ray diffraction. The results show a clear depth dependence of the phase transition on scales of a few microns. The measurements support a model in which there are tetragonal domains forming in the sample at temperatures much higher than the bulk phase transition temperature. Moreover, we find that these domains tend to form at higher temperatures preferentially near the free surface of the crystal. The details of the tetragonal domain formation and their depth/lateral dependencies are discussed.

  15. Phase and Texture of Solution-Processed Copper Phthalocyanine Thin Films Investigated by Two-Dimensional Grazing Incidence X-Ray Diffraction

    Directory of Open Access Journals (Sweden)

    Lulu Deng

    2011-07-01

    Full Text Available The phase and texture of a newly developed solution-processed copper phthalocyanine (CuPc thin film have been investigated by two-dimensional grazing incidence X-ray diffraction. The results show that it has β phase crystalline structure, with crystallinity greater than 80%. The average size of the crystallites is found to be about 24 nm. There are two different arrangements of crystallites, with one dominating the diffraction pattern. Both of them have preferred orientation along the thin film normal. Based on the similarities to the vacuum deposited CuPc thin films, the new solution processing method is verified to offer a good alternative to vacuum process, for the fabrication of low cost small molecule based organic photovoltaics.

  16. Some simple ideas on x-ray reflection and grazing-incidence diffraction from thin surfactant films

    DEFF Research Database (Denmark)

    Kjær, K.

    1994-01-01

    For Langmuir films of long linear amphiphilic molecules at the air-water interface, grazing-incidence diffraction data resolved in terms of both the horizontal and vertical components of the scattering angle can be evaluated to a fair level of detail by means of a slide rule. Specular reflection...

  17. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  18. Depth profiling study of in situ CdCl{sub 2} treated CdTe/CdS heterostructure with glancing angle incidence X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Vamsi Krishna, K.; Dutta, V

    2004-03-01

    CdTe thin films have been deposited using spray pyrolysis technique without and with in situ CdCl{sub 2} treatment. Scanning electron microscopy studies show enhanced grain growth in the presence of CdCl{sub 2}. Glancing angle incidence X-ray diffraction is used for the micro structural study of polycrystalline CdS/CdTe heterostructure at different depths by changing the incident angle. Spraying of CdCl{sub 2} on CdS prior to CdTe deposition promotes S diffusion throughout CdTe film and also Te diffusion into CdS. Whereas spraying of CdCl{sub 2} in between CdTe deposition prevents S diffusion partially and Te diffusion completely. There is an associated change in the microstress of the CdTe film at different layers. The films without CdCl{sub 2} treatment show compressive microstress varying from -98 to -158 MPa with increasing incident angle. CdCl{sub 2} spray during CdTe deposition shows compressive microstress, which varies from -98 MPa at the interface to -19 MPa near the surface and CdCl{sub 2} spray prior to CdTe deposition leads to a mildly tensile stress, from +40 to +20 MPa, which is very close to the standard shear stress of {approx}10 MPa for CdTe.

  19. X-ray holography

    CERN Document Server

    Faigel, G; Belakhovsky, M; Marchesini, S; Bortel, G

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples.

  20. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  1. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  2. Analysis of InGaN nanodots grown by droplet heteroepitaxy using grazing incidence small-angle X-ray scattering and electron microscopy

    Science.gov (United States)

    Woodward, J. M.; Nikiforov, A. Yu.; Ludwig, K. F.; Moustakas, T. D.

    2017-08-01

    We present a detailed structural investigation of self-assembled indium gallium nitride nanodots grown on c-plane aluminum nitride templates by the droplet heteroepitaxy technique in a plasma-assisted molecular beam epitaxy reactor. Various growth parameters, including the total coverage of the metal species, relative and total metal effusion fluxes, and nitridation temperature were investigated. Analyses of in situ reflection high-energy electron diffraction patterns and comparison with simulations showed that the resulting crystal structure was a mixture of wurtzite and twinned zinc blende phases, with the zinc blende phase increasingly dominant for lower metal coverages and lower nitridation temperatures, and the wurtzite phase increasingly dominant for higher nitridation temperature. Studies by field emission scanning electron microscopy and atomic force microscopy revealed that the nanodots exhibit trimodal size distributions, with the dot morphologies of the intermediate size mode often resembling aggregations of distinct clusters. Nanodots grown at higher nitridation temperatures had larger inter-dot spacings, with hexagonal in-plane ordering observable at a sufficiently high temperature. Using grazing incidence small angle X-ray scattering, we determined the nanodots to be approximately truncated cone shaped, and extracted the mean radius, height, and inter-dot distance for each distribution. Microstructural investigations of the nanodots by cross-sectional transmission electron microscopy indicated that the majority of the dots were formed in dislocation-free regions, and confirmed that the intermediate size dots were approximately truncated cone shaped and consisted of both zinc blende and wurtzite regions. Mapping of the elemental distributions by energy dispersive X-ray spectroscopy in scanning transmission electron microscopy mode indicated highly nonuniform indium distributions within both small and intermediate size dots which are potentially

  3. Strain, size and composition of InAs quantum sticks, embedded in InP, determined via X-ray anomalous diffraction and diffraction anomalous fine structure in grazing incidence

    International Nuclear Information System (INIS)

    Letoublon, A.; Favre-Nicolin, V.; Renevier, H.; Proietti, M.G.; Monat, C.; Gendry, M.; Marty, O.; Priester, C.

    2005-01-01

    We report on the study of strain, size and composition of small-size encapsulated semiconductor nanostructures. We show that the partial structure factor of As atoms in InAs stick-like nanostructures (quantum sticks), embedded in InP, can be directly extracted from grazing incidence anomalous X-ray diffraction maps at the As K-edge. We have recovered the average height and strain of the islands and determined their composition. The average height of the quantum sticks (QSs), as deduced from the width of the structure factor profile is 2.54 nm. The InAs out of plane deformation, relative to InP, is equal to 6.1%. Fixed-Q anomalous diffraction spectra, measured at the As K-edge, in grazing incidence provide clear evidence of pure InAs QSs. This is confirmed by the analysis of the diffraction anomalous fine structure (DAFS) that also gives a direct way to recover the strain accomodation inside the quantum sticks. Finite difference method calculations reproduce well the diffraction data. Chemical mixing at interfaces is at most 1 ML. This paper shows that ultimate application of anomalous diffraction and DAFS together with reciprocal space maps is a powerful method to sudy the structural properties of nanostructures

  4. Contribution to time resolved X-ray fluence and differential spectra measurement method improvement in 5-200 KeV range. Application to pulsed emission sources

    International Nuclear Information System (INIS)

    Vie, M.

    1983-09-01

    Two types of sensors have been developed to measure locally the time-resolved fluence and differential energetic spectrum of pulsed X-ray in the energy range 5 to 200 keV. Rise time of these sensors is very short (10 ns) in order to permit time-resolved measurements. Fluence sensors have been developed by putting filters in front of detector in order to make sensor response independent of X-ray energy and proportional to X-ray fluence. The energetic differential spectrum was calculated by way of a method similar to the ROSS method but using filters separated within a pair defining adjacent spectral width. A detailed analysis of uncertainties affecting calculated fluence and spectrum has been done [fr

  5. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  6. Chest X-Ray

    Medline Plus

    Full Text Available ... loose, comfortable clothing. You may be asked to change into a gown. You may have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  8. Resonant inelastic x-ray scattering studies of elementary excitations

    NARCIS (Netherlands)

    Ament, Lucas Johannes Peter (Luuk)

    2010-01-01

    Resonant Inelastic X-ray Scattering (RIXS) is an X-ray in, X-ray out technique that enables one to study the dispersion of excitations in solids. In this thesis, we investigated how various elementary excitations of transition metal oxides show up in RIXS spectra.

  9. Combining MinXSS and RHESSI X-ray Spectra for a Comprehensive View of the Temperature Distribution in Solar Flares

    Science.gov (United States)

    Caspi, A.; McTiernan, J. M.; Mason, J. P.; Moore, C. S.; Shih, A. Y.; Warren, H.; Woods, T. N.

    2016-12-01

    Solar flares explosively release large amounts of magnetic energy, a significant fraction of which goes into transient heating of coronal plasma to temperatures up to tens of MK. Decades of observations have shown that flares are multi-thermal, exhibiting broad temperature distributions or "differential emission measures" (DEMs). Recent studies suggest that the hottest parts of the DEM evolve differently from, and are heated by a different physical mechanism than, the DEM bulk. For example, the peak temperature of the hot, likely in-situ-heated plasma observed by RHESSI correlates significantly differently with flare intensity (GOES class) than does the cooler, likely chromospherically evaporated plasma observed by GOES XRS and/or Yohkoh BCS. These studies, however, used discrete (iso-/bi-) thermal approximations, in part because temperature determinations by the ratio of 2-channel GOES photometer data or selected BCS lines necessitated such methods. Consequently, the exact DEM profile, its evolution, and how these correlate with other flare parameters, remain poorly known. The MinXSS CubeSat deployed from the ISS in May 2016, and since June has observed (at least) 7 M-class and over 40 C-class flares. MinXSS's X123 spectrometer measures solar soft X-rays (SXRs) from 0.5 to 30 keV with 0.15 keV FWHM resolution; this energy range entirely covers both GOES XRS passbands, and overlaps with and extends the RHESSI observing range with 5x better resolution. It includes the thermal continuum emission from plasmas with temperatures down to 2 MK, as well as a number of mid- and high-temperature spectral lines from various low- and high-FIP ion species, providing critical temperature diagnostics for studying flare DEMs with far greater fidelity than is possible with GOES, or using RHESSI alone. We present spectral analyses of several flares observed simultaneously by MinXSS and RHESSI. We compare and contrast the observations of each instrument separately, and present the

  10. Numerical method for inverting 1s2p resonant inelastic x-ray scattering spectra: Interpretation of hidden electronic excitations in CuO

    Czech Academy of Sciences Publication Activity Database

    Dräger, G.; Machek, Pavel

    2009-01-01

    Roč. 79, č. 3 (2009), 033103/1-033103/4 ISSN 1098-0121 Institutional research plan: CEZ:AV0Z10100521 Keywords : copper compounds * Fredholm integral equations * numerical analysis * oscillator strengths * strongly correlated electron systems * XANES * X-ray scattering Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.475, year: 2009

  11. X-ray generator

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1976-01-01

    An apparatus and a method are described for producing coherent secondary x-rays that are controlled as to direction by illuminating a mixture of high z and low z gases with an intense burst of primary x-rays. The primary x-rays are produced with a laser activated plasma, and these x-rays strip off the electrons of the high z atoms in the lasing medium, while the low z atoms retain their electrons. The neutral atoms transfer electrons to highly excited states of the highly stripped high z ions giving an inverted population which produces the desired coherent x-rays. In one embodiment, a laser, light beam provides a laser spark that produces the intense burst of coherent x-rays that illuminates the mixture of high z and low z gases, whereby the high z atoms are stripped while the low z ones are not, giving the desired mixture of highly ionized and neutral atoms. Means for magnetically confining and stabilizing the plasma are disclosed for controlling the direction of the x-rays

  12. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  13. X-ray stars observed in LAMOST spectral survey

    Science.gov (United States)

    Lu, Hong-peng; Zhang, Li-yun; Han, Xianming L.; Shi, Jianrong

    2018-05-01

    X-ray stars have been studied since the beginning of X-ray astronomy. Investigating and studying the chromospheric activity from X-ray stellar optical spectra is highly significant in providing insights into stellar magnetic activity. The big data of LAMOST survey provides an opportunity for researching stellar optical spectroscopic properties of X-ray stars. We inferred the physical properties of X-ray stellar sources from the analysis of LAMOST spectra. First, we cross-matched the X-ray stellar catalogue (12254 X-ray stars) from ARXA with LAMOST data release 3 (DR3), and obtained 984 good spectra from 713 X-ray sources. We then visually inspected and assigned spectral type to each spectrum and calculated the equivalent width (EW) of Hα line using the Hammer spectral typing facility. Based on the EW of Hα line, we found 203 spectra of 145 X-ray sources with Hα emission above the continuum. For these spectra we also measured the EWs of Hβ, Hγ, Hδ and Ca ii IRT lines of these spectra. After removing novae, planetary nebulae and OB-type stars, we found there are 127 X-ray late-type stars with Hα line emission. By using our spectra and results from the literature, we found 53 X-ray stars showing Hα variability; these objects are Classical T Tauri stars (CTTs), cataclysmic variables (CVs) or chromospheric activity stars. We also found 18 X-ray stars showing obvious emissions in the Ca ii IRT lines. Of the 18 X-ray stars, 16 are CTTs and 2 are CVs. Finally, we discussed the relationships between the EW of Hα line and X-ray flux.

  14. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  15. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  17. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small ... limitations of Panoramic X-ray? What is Panoramic X-ray? Panoramic radiography , also called panoramic x-ray , is ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  19. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  20. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  1. X-Ray Exam: Hip

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: ... darker. An X-ray technician takes the X-rays. An X-ray technician in the radiology department of a ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  3. Lumbosacral spine x-ray

    Science.gov (United States)

    X-ray - lumbosacral spine; X-ray - lower spine ... The test is done in a hospital x-ray department or your health care provider's office by an x-ray technician. You will be asked to lie on the x-ray table ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  5. X-ray metrology for ULSI structures

    International Nuclear Information System (INIS)

    Bowen, D. K.; Matney, K. M.; Wormington, M.

    1998-01-01

    Non-destructive X-ray metrological methods are discussed for application to both process development and process control of ULSI structures. X-ray methods can (a) detect the unacceptable levels of internal defects generated by RTA processes in large wafers, (b) accurately measure the thickness and roughness of layers between 1 and 1000 nm thick and (c) can monitor parameters such as crystallographic texture and the roughness of buried interfaces. In this paper we review transmission X-ray topography, thin film texture measurement, grazing-incidence X-ray reflectivity and high-resolution X-ray diffraction. We discuss in particular their suitability as on-line sensors for process control

  6. Packing stress reduction in polymer-lipid monolayers at the air-water interface: An X-ray grazing-incidence diffraction and reflectivity study

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, T.L.; Majewski, J.; Howes, P.B.; Kjaer, K.; Nahmen, A. von; Lee, K.Y.C.; Ocko, B.; Israelachvili, J.N.; Smith, G.S.

    1999-08-25

    Using synchrotron grazing-incidence X-ray diffraction (GIXD) and reflectivity (XR), the authors have determined the in-plane and out-of-plane structure of phospholipid monolayers at the air-water interface as a function of hydrophilic lipid headgroup size. Di-stearoyl-phosphatidyl-ethanolamine (DSPE) lipid monolayers were systematically modified by chemically grafting hydrophilic poly(ethylene glycol) (PEG) chains of MW = 90 g/mol (2 ethylene oxide, EO, units), MW = 350 g/mol (8 EO units), and MW = 750 g/mol (17 EO units) to the lipid headgroups. The monolayers were studied in the solid phase at a surface pressure of 42 mN/m. At these high lipid packing densities, the PEG chains are submerged in the water subphase. The increased packing stresses from these bulky polymer headgroups distort the unit cell and the in-plane packing modes of the monolayers, leading to large out-of-plane alterations and staggering of the lipid molecules. Surprisingly, a change in the molecular packing of the monolayer toward higher packing densities (lower area per molecule) was observed on increasing the PEG MW to 750 g/mol (17 EO units). This rearrangement of the monolayer structure may be due to a conformational change in the PEG chains.

  7. Structure of ultrathin films of Co on Cu(111) from normal-incidence x-ray standing wave and medium-energy ion scattering measurements

    International Nuclear Information System (INIS)

    Butterfield, M.T.; Crapper, M.D.; Noakes, T.C.Q.; Bailey, P.; Jackson, G.J.; Woodruff, D.P.

    2000-01-01

    Applications of the techniques of normal-incidence x-ray standing wave (NIXSW) and medium-energy ion scattering (MEIS) to the elucidation of the structure of an ultrathin metallic film, Co on Cu(111), are reported. NIXSW and MEIS are shown to yield valuable and complementary information on the structure of such systems, yielding both the local stacking sequence and the global site distribution. For the thinnest films of nominally two layers, the first layer is of entirely fcc registry with respect to the substrate, but in the outermost layer there is significant occupation of hcp local sites. For films up to 8 monolayers (ML) thick, the interlayer spacing of the Co layers is 0.058±0.006 Aa smaller than the Cu substrate (111) layer spacing. With increasing coverage, the coherent fraction of the (1(bar sign)11) NIXSW decreases rapidly, indicating that the film does not grow in a fcc continuation beyond two layers. For films in this thickness range, hcp-type stacking dominates fcc twinning by a ratio of 2:1. The variation of the (1(bar sign)11) NIXSW coherent fraction with thickness shows that the twinning occurs close to the Co/Cu interface. For thicker films of around 20 ML deposited at room temperature, medium-energy ion scattering measurements reveal a largely disordered structure. Upon annealing to 300 deg. C the 20-ML films order into a hcp structure

  8. Three-Dimensional Morphology Control Yielding Enhanced Hole Mobility in Air-Processed Organic Photovoltaics: Demonstration with Grazing-Incidence Wide-Angle X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Levi M. J. [School of Polymers; Bhattacharya, Mithun [School of Polymers; Wu, Qi [School of Polymers; Youm, Sang Gil [Department of Chemistry, Louisiana State University, 232 Choppin Hall, Baton Rouge, Louisiana 70803, United States; Nesterov, Evgueni E. [Department of Chemistry, Louisiana State University, 232 Choppin Hall, Baton Rouge, Louisiana 70803, United States; Morgan, Sarah E. [School of Polymers

    2017-06-28

    Polymer organic photovoltaic (OPV) device performance is defined by the three-dimensional morphology of the phase-separated domains in the active layer. Here, we determine the evolution of morphology through different stages of tailored solvent vapor and thermal annealing techniques in air-processed poly(3-hexylthiophene-2,5-diyl)/phenyl-C61-butyric acid methyl ester-based OPV blends. A comparative evaluation of the effect of solvent type used for vapor annealing was performed using grazing-incidence wide-angle X-ray scattering, atomic force microscopy, and UV–vis spectroscopy to probe the active-layer morphology. A nonhalogenated orthogonal solvent was found to impart controlled morphological features within the exciton diffusion length scales, enhanced absorbance, greater crystallinity, increased paracrystalline disorder, and improved charge-carrier mobility. Low-boiling, fast-diffusing isopropanol allowed the greatest control over the nanoscale structure of the solvents evaluated and yielded a cocontinuous morphology with narrowed domains and enhanced paths for the charge carrier to reach the anode.

  9. In situ electrochemical impedance spectroscopy/synchrotron radiation grazing incidence X-ray diffraction-A powerful new technique for the characterization of electrochemical surfaces and interfaces

    International Nuclear Information System (INIS)

    De Marco, Roland; Jiang, Z.-T.; Martizano, Jay; Lowe, Alex; Pejcic, Bobby; Riessen, Arie van

    2006-01-01

    A marriage of electrochemical impedance spectroscopy (EIS) and in situ synchrotron radiation grazing incidence X-ray diffraction (SR-GIXRD) has provided a powerful new technique for the elucidation of the mechanistic chemistry of electrochemical systems. In this study, EIS/SR-GIXRD has been used to investigate the influence of metal ion buffer calibration ligands, along with natural organic ligands in seawater, on the behaviour of the iron chalcogenide glass ion-selective electrode (ISE). The SR-GIXRD data demonstrated that citrate - a previously reported poor iron calibration ligand for the analysis of seawater - induced an instantaneous and total dissolution of crystalline GeSe and Sb 2 Se 3 in the modified surface layer (MSL) of the ISE, while natural organic ligands in seawater and a mixture of ligands in a mimetic seawater ligand system protected the MSL's crystalline inclusions of GeSe and Sb 2 Se 3 from oxidative attack. Expectedly, the EIS data showed that citrate induced a loss in the medium frequency time constant for the MSL of the ISE, while seawater's natural organic ligands and the mimetic ligand system preserved the medium frequency EIS response characteristics of the ISE's MSL. The new EIS/SR-GIXRD technique has provided insights into the suitability of iron calibration ligands for the analysis of iron in seawater

  10. Three-Dimensional Morphology Control Yielding Enhanced Hole Mobility in Air-Processed Organic Photovoltaics: Demonstration with Grazing-Incidence Wide-Angle X-ray Scattering.

    Science.gov (United States)

    Moore, Levi M J; Bhattacharya, Mithun; Wu, Qi; Youm, Sang Gil; Nesterov, Evgueni E; Morgan, Sarah E

    2017-07-12

    Polymer organic photovoltaic (OPV) device performance is defined by the three-dimensional morphology of the phase-separated domains in the active layer. Here, we determine the evolution of morphology through different stages of tailored solvent vapor and thermal annealing techniques in air-processed poly(3-hexylthiophene-2,5-diyl)/phenyl-C 61 -butyric acid methyl ester-based OPV blends. A comparative evaluation of the effect of solvent type used for vapor annealing was performed using grazing-incidence wide-angle X-ray scattering, atomic force microscopy, and UV-vis spectroscopy to probe the active-layer morphology. A nonhalogenated orthogonal solvent was found to impart controlled morphological features within the exciton diffusion length scales, enhanced absorbance, greater crystallinity, increased paracrystalline disorder, and improved charge-carrier mobility. Low-boiling, fast-diffusing isopropanol allowed the greatest control over the nanoscale structure of the solvents evaluated and yielded a cocontinuous morphology with narrowed domains and enhanced paths for the charge carrier to reach the anode.

  11. In-situ grazing incidence X-ray diffraction measurements of relaxation in Fe/MgO/Fe epitaxial magnetic tunnel junctions during annealing

    Energy Technology Data Exchange (ETDEWEB)

    Eastwood, D.S. [Department of Physics, Durham University, South Road, Durham DH1 3LE (United Kingdom); Ali, M.; Hickey, B.J. [Department of Physics and Astronomy, University of Leeds, Leeds LS2 1JT (United Kingdom); Tanner, B.K., E-mail: b.k.tanner@dur.ac.uk [Department of Physics, Durham University, South Road, Durham DH1 3LE (United Kingdom)

    2013-12-15

    The relaxation of Fe/MgO/Fe tunnel junctions grown epitaxially on (001) MgO substrates has been measured by in-situ grazing incidence in-plane X-ray diffraction during the thermal annealing cycle. We find that the Fe layers are fully relaxed and that there are no irreversible changes during annealing. The MgO tunnel barrier is initially strained towards the Fe but on annealing, relaxes and expands towards the bulk MgO value. The strain dispersion is reduced in the MgO by about 40% above 480 K post-annealing. There is no significant change in the “twist” mosaic. Our results indicate that the final annealing stage of device fabrication, crucial to attainment of high TMR, induces substantial strain relaxation at the MgO barrier/lower Fe electrode interface. - Highlights: • Lattice relaxation of Fe/MgO/Fe epitaxial magnetic tunnel junctions measured. • In-plane lattice parameter of Fe equal to bulk value; totally relaxed. • MgO barrier initially strained towards the Fe but relaxes on annealing. • Reduction in strain dispersion in the MgO barrier by 40% above about 470 K. • No change in the in-plane “twist” mosaic throughout the annealing cycle.

  12. Structural analysis on a block copolymer thin film by in-situ neutron and x-ray grazing-incidence scattering techniques

    International Nuclear Information System (INIS)

    Torikai, Naoya; Yamada, Norifumi L.; Kawaguchi, Daisuke

    2011-01-01

    Structural change of a phase-separated block copolymer thin film with polystyrene (PS) and poly(2-vinylpyridine)(P2VP) in contact with different solvents was observed by in-situ neutron reflectometry using a conventional cell for a solid/liquid interface, and time evolution of phase-separated structure after a temperature jump to 200degC was observed for diblock and triblock copolymer thin films of PS and P2VP by grazing-incidence small-angle X-ray scattering (GISAXS). When PS-P2VP diblock copolymer thin film was contacted with methanol and water, the structural change was induced by penetration of small amount of the solvent into the film, and the original structure was almost recovered after drying it. Also, the diblock copolymer thin film was easily dissolved into toluene, and the original structure was never recovered after the solvent contact. After the temperature jump the lateral correlation spots were evolved with a time in the GISAXS pattern similarly for either block copolymer thin film with spherical structure, though their as-spun states were different. (author)

  13. Crystal structure analysis in solution-processed uniaxially oriented polycrystalline thin film of non-peripheral octahexyl phthalocyanine by grazing incidence wide-angle x-ray scattering techniques

    Science.gov (United States)

    Ohmori, Masashi; Uno, Takashi; Nakatani, Mitsuhiro; Nakano, Chika; Fujii, Akihiko; Ozaki, Masanori

    2016-10-01

    Uniaxially oriented thin films of metal-free non-peripherally octahexyl-substituted phthalocyanine (C6PcH2), which exhibits high carrier mobility, have been fabricated by the bar-coating technique, which is a simple solution process. The molecular orientation and molecular steps in the thin film were observed by the polarized spectroscopy and the atomic force microscopy, respectively. The three-dimensional molecular packing structure in the thin film was investigated by the grazing incidence wide-angle X-ray scattering technique with an in-plane sample rotation. The crystal orientation was clarified, and the three-dimensional molecular packing structure of the thin film was found to match the single crystal structure. Moreover, the X-ray diffraction patterns of the oriented thin films were simulated by using the lattice parameters of C6PcH2 single crystal to reproduce the observed X-ray diffraction patterns.

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... Radiology and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  15. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight February is American Heart Month Recently posted: Carotid Intima-Media Thickness Test ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... Abdominal Ultrasound Video: Pelvic Ultrasound Medical Imaging Costs Radiology and You Take our survey Sponsored by Image/ ... Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript ... Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You ...

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... and use a very small dose of ionizing radiation to produce pictures of the inside of the ... x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: Carotid Intima-Media Thickness ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: How to Obtain and ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  6. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: Video: The Basketball Game: ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  7. X-Ray Lasers

    Science.gov (United States)

    Eder, David C.

    1998-05-01

    We provide an overview of the status of x-ray laser development worldwide with particular attention given to activities at LLNL. Since the demonstration of x-ray lasing 14 years ago there has been major progress in achieving shorter wavelengths, higher energies per pulse, higher efficiency, shorter pulse durations, etc. Original x-ray lasers used large kJ class lasers to achieve lasing in mid-Z materials with electron collisional pumping in the highly stripped ion being the most successful process for populating the upper-laser state. The two most common electron configurations for these collisional x-ray lasers are Ne-like and Ni-like ions. Through the use of prepulses and short picosecond driving pulses, transient collisional x-ray lasing schemes have been demonstrated using lasers with only a few Joules per pulse. An interesting aspect of these lasers is the time lag in reaching ionization equilibrium helps in obtaining high gain coefficients. A different approach to x-ray lasing is also being studied where lasing occurs in a singly ionized ion following innershell photoionization. The major requirement of the driving laser in this case is an ultrashort pulse duration (rise time to achieve lasing prior to collisional ionization of outershell electrons. In the area of applications, most of the work has been for single pulse experiments such as plasma and biological imaging. However, many of the new x-ray lasers achieve high average power by having a reasonable repetition rate of order 10 Hz and we briefly discuss relevant applications for these x-ray lasers. This work performed under the auspices of US DOE by LLNL under Contract No. W-7405-Eng-48.

  8. X-Ray Optics

    Science.gov (United States)

    1990-01-01

    samples. Another exciting application of microbeam of x-rays is in that of high pressure x-ray diffraction from small samples. Along this line, Yan...will be presented by Jonathan in February at the Physics and Chemistry of Semiconductor Interfaces conference and in March at the American Physical...VUV9 conference this summer. Jeff has also worked on developing software that makes use of the scattering factor tables for both microvax and IBM PC

  9. Dipole and quadrupole contributions to polarized Cu K x-ray absorption near-edge structure spectra of CuO

    Czech Academy of Sciences Publication Activity Database

    Bocharov, S.; Kirchner, T.; Dräger, G.; Šipr, Ondřej; Šimůnek, Antonín

    2001-01-01

    Roč. 63, - (2001), s. 045104-1-045104-10 ISSN 0163-1829 R&D Projects: GA ČR GA202/99/0404; GA ČR GA203/99/0067 Institutional research plan: CEZ:AV0Z1010914 Keywords : high-Tc superconductots * polarized Cu K x-ray absorption * CuO Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.070, year: 2001

  10. Soft X-ray spectroscopy of nanoparticles by velocity map imaging

    Science.gov (United States)

    Kostko, O.; Xu, B.; Jacobs, M. I.; Ahmed, M.

    2017-07-01

    Velocity map imaging (VMI), a technique traditionally used to study chemical dynamics in the gas phase, is applied here to study X-ray photoemission from aerosol nanoparticles. Soft X-rays from the Advanced Light Source synchrotron, probe a beam of nanoparticles, and the resulting photoelectrons are velocity mapped to obtain their kinetic energy distributions. A new design of the VMI spectrometer is described. The spectrometer is benchmarked by measuring vacuum ultraviolet photoemission from gas phase xenon and squalene nanoparticles followed by measurements using soft X-rays. It is demonstrated that the photoelectron distribution from X-ray irradiated squalene nanoparticles is dominated by secondary electrons. By scanning the photon energies and measuring the intensities of these secondary electrons, a near edge X-ray absorption fine structure (NEXAFS) spectrum is obtained. The NEXAFS technique is used to obtain spectra of aqueous nanoparticles at the oxygen K edge. By varying the position of the aqueous nanoparticle beam relative to the incident X-ray beam, evidence is presented such that the VMI technique allows for NEXAFS spectroscopy of water in different physical states. Finally, we discuss the possibility of applying VMI methods to probe liquids and solids via X-ray spectroscopy.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  17. Theoretical concepts of X-ray nanoscale analysis theory and applications

    CERN Document Server

    Benediktovitch, Andrei; Ulyanenkov, Alexander

    2013-01-01

    This book provides a concise survey of modern theoretical concepts of X-ray materials analysis. The principle features of the book are: basics of X-ray scattering, interaction between X-rays and matter and new theoretical concepts of X-ray scattering. The various X-ray techniques are considered in detail: high-resolution X-ray diffraction, X-ray reflectivity, grazing-incidence small-angle X-ray scattering and X-ray residual stress analysis. All the theoretical methods presented use the unified physical approach. This makes the book especially useful for readers learning and performing data ana

  18. Uniformity of the soft-x-ray emissions from gold foils irradiated by OMEGA laser beams determined by a two-mirror normal-incidence microscope with multilayer coatings

    International Nuclear Information System (INIS)

    Seely, John F.; Boehly, Thomas; Pien, Gregory; Bradley, David

    1998-01-01

    A two-mirror normal-incidence microscope with multilayer coatings was used to image the soft-x-ray emissions from planar foils irradiated by OMEGA laser beams. The bandpass of the multilayer coatings was centered at a wavelength of 48.3 Angstrom (257-eV energy) and was 0.5 Angstrom wide. Five overlapping OMEGA beams, without beam smoothing, were typically incident on the gold foils. The total energy was 1500 J, and the focused intensity was 6x10 13 Wcm -2 . The 5.8x magnified images were recorded by a gated framing camera at various times during the 3-ns laser pulse. A pinhole camera imaged the x-ray emission in the energy range of >2 keV. On a spatial scale of 10 μm, it was found that the soft-x-ray images at 257 eV were quite uniform and featureless. In contrast, the hard-x-ray images in the energy range of >2 kev were highly nonuniform with numerous features of size 150 μm. copyright 1998 Optical Society of America

  19. Constellation-X to Generation-X: evolution of large collecting area moderate resolution grazing incidence x-ray telescopes to larger area high-resolution adjustable optics

    Science.gov (United States)

    Reid, Paul B.; Cameron, Robert A.; Cohen, Lester; Elvis, Martin; Gorenstein, Paul; Jerius, Diab; Petre, Robert; Podgorski, William A.; Schwartz, Daniel A.; Zhang, William W.

    2004-10-01

    Large collecting area x-ray telescopes are designed to study the early Universe, trace the evolution of black holes, stars and galaxies, study the chemical evolution of the Universe, and study matter in extreme environments. The Constellation-X mission (Con-X), planned for launch in 2016, will provide ~ 10^4 cm^2 collecting area with 15 arc-sec resolution, with a goal of 5 arc-sec. Future missions require larger collecting area and finer resolution. Generation-X (Gen-X), a NASA Visions Mission, will achieve 100 m^2 effective area at 1 keV and angular resolution of 0.1 arc-sec, half power diameter. We briefly describe the Con-X flowdown of imaging requirements to reflector figure error. To meet requirements beyond Con-X, Gen-X optics will be thinner and more accurately shaped than has ever been accomplished. To meet these challenging goals, we incorporate for the first time active figure control with grazing incidence optics. Piezoelectric material will be deposited in discrete cells directly on the back surface of the optical segments, with the strain directions oriented parallel to the surface. Differential strain between the two layers of the mirror causes localized bending in two directions, enabling local figure control. Adjusting figure on-orbit eases fabrication and metrology. The ability to make changes to mirror figure adds margin by mitigating risk due to launch-induced deformations and/or on-orbit degradation. We flowdown the Gen-X requirements to mirror figure and four telescope designs, and discuss various trades between the designs.

  20. Design and performance of the 2-ID-B scanning x-ray microscope

    Science.gov (United States)

    McNulty, Ian; Frigo, Sean P.; Retsch, Cornelia C.; Wang, Yuxin; Feng, Yipeng; Qian, Yonglin; Trakhtenberg, Emil M.; Tieman, Brian; Cha, B.-C.; Goetze, K.; Mooney, Timothy M.; Haddad, Waleed S.

    1998-11-01

    We have constructed a high resolution scanning x-ray microscopy at the 2-ID-B beamline at the Advanced Photon Source for 1-4 keV x-ray imaging and microspectroscopy experiments. The microscope uses a Fresnel zone plate to focus coherent x-ray undulator radiation to a 150 nm focal spot on a sample. The spectral flux in the focus is 108 ph/s/0.1 percent BW. X- ray photons transmitted by the sample are detected by an avalanche photodiode as the sample is scanned to form an absorption image. The sample stage has both coarse and fine translation axes for raster scanning and a rotation axis for microtomography experiments. The incident x- ray beam energy can also be scanned and a rotation axis for microtomography experiments. The incident x-ray beam energy can also be scanned via the 2-ID-B monochromator while the sample is kept in focus to record spatially resolved absorption spectra. We have measured the performance of the instrument with various test objects. THe microscope hardware, software, and performance are discussed in this paper.

  1. Reconstruction of X-rays spectra of clinical linear accelerators using the generalized simulated annealing method; Reconstrucao de espectros de raios-X de aceleradores lineares clinicos usando o metodo de recozimento simulado generalizado

    Energy Technology Data Exchange (ETDEWEB)

    Manrique, John Peter O.; Costa, Alessandro M., E-mail: johnp067@usp.br, E-mail: amcosta@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil)

    2016-07-01

    The spectral distribution of megavoltage X-rays used in radiotherapy departments is a fundamental quantity from which, in principle, all relevant information required for radiotherapy treatments can be determined. To calculate the dose delivered to the patient who make radiation therapy, are used treatment planning systems (TPS), which make use of convolution and superposition algorithms and which requires prior knowledge of the photon fluence spectrum to perform the calculation of three-dimensional doses and thus ensure better accuracy in the tumor control probabilities preserving the normal tissue complication probabilities low. In this work we have obtained the photon fluence spectrum of X-ray of the SIEMENS ONCOR linear accelerator of 6 MV, using an character-inverse method to the reconstruction of the spectra of photons from transmission curves measured for different thicknesses of aluminum; the method used for reconstruction of the spectra is a stochastic technique known as generalized simulated annealing (GSA), based on the work of quasi-equilibrium statistic of Tsallis. For the validation of the reconstructed spectra we calculated the curve of percentage depth dose (PDD) for energy of 6 MV, using Monte Carlo simulation with Penelope code, and from the PDD then calculate the beam quality index TPR{sub 20/10}. (author)

  2. Electronic structure, X-ray spectra and magnetic properties of nonstoichiometric LiCoO sub 2 sub - subdelta and Na sub x CoO sub 2 oxides

    CERN Document Server

    Galakhov, V R; Karelina, V V; Kellerman, D G; Gorshkov, V S; Nojmann, M

    2002-01-01

    One studied magnetic susceptibility, X-ray photoelectron and X-ray emission spectra of LiCoO sub 2 sub - subdelta and Na sub x CoO sub 2 nonstoichiometric oxides. One analyzed structures of LiCoO sub 2 valent band. Ob the basis of O K alpha-spectra of emission measuring one determined hole concentration in LiNiO sub 2 and LiCoO sub 2 oxygen 2p-band. Measurements of Co 2p- and Co 3s-photoelectron spectra have shown that Co sup 3 sup + ions are in S = 0 low-spin state. In LiCoO sub 2 sub - subdelta reduced oxides oxygen deficit causes formation of cobalt bivalent ions. Deficit of alkali metal in Na sub x CoO sub 2 results in hole formation in oxygen 2p-band not varying d sup 6 electron configuration of ground state of cobalt ions

  3. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  4. Toward Adaptive X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Tim W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peer; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffrey J.; hide

    2011-01-01

    Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

  5. Spectroscopic Studies of X-Ray Binary Pulsars

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    ... those X-ray sources. A merit of investigating soft excess feature using XBP spectra is that it allows us to search pulse modulation of the soft component. Anomalous X-ray pulsars (AXPs) are also known to have a two component spectra, a steep power law and blackbody emission model (e.g., Mereghetti & Stella 1995).

  6. Characterization of Metalloproteins and Biomaterials by X-ray Absorption Spectroscopy and X-ray Diffraction

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl

    by estimation of the water content by thermogravimetric analysis. Bone tissue from dogs treated with strontiummalonate was studied using XAS. A new approach for analysing the X-ray absorption spectra resulted in a compositional model, from which the relative distribution of strontium in the different bone......-ray crystallography and X-ray absorption spectroscopy (XAS) applied to studying different hexameric insulin conformations. (iii) The structures of polymorphs of strontium ranelate and the distribution of strontium in bone tissue. A procedure for fast identification and verification of protein powders using XRPD...... and R6) were solved by single crystal X-ray diffraction (XRD) to 1.40 Å, 1.30 Å and 1.80 Å resolution, respectively. The zinc coordination in each conformation was studied by XAS including both extended X-ray absorption fine structure (EXAFS) spectroscopy and X-ray absorption near edge structure (XANES...

  7. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  8. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  9. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  10. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  11. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  12. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  13. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  14. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  15. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  16. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  17. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  18. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  19. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  20. A compact soft x-ray (0.1–1.2 keV) calibration bench for radiometric measurements using an original versatile Rowland circle grazing incidence monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr

    2017-05-21

    This paper describes an original Rowland circle grazing incidence spectrometer used as a monochromator for a soft x-ray Manson source in order to calibrate both the source and detectors over the 0.1–1.2 keV spectral range. The originality of the instrument lies on a patented vacuum manipulator which allows the simultaneous boarding of two detectors, one (reference) for measuring the monochromatic radiation and the second to be calibrated. In order to achieve this, the vacuum manipulator is able to interchange, in vacuum, one detector with the other in front of the exit slit of the monochromatizing stage. One purpose of this apparatus was to completely eliminate the intrinsic bremsstrahlung emission of the x-ray diode source and isolate each characteristic line for quantitative detector calibrations. Obtained spectral resolution (Δλ/λ<10{sup −2}) and spectral purity (>98%) fully meet this objective. Initially dimensioned to perform calibration of bulky x-ray cameras unfolded on the Laser MégaJoule Facility, other kinds of detector can be obviously calibrated using this instrument. A brief presentation of the first calibration of an x-ray CCD through its quantum efficiency (QE) measurement is included in this paper as example. Comparison with theoretical model for QE and previous measurements at higher energy are finally presented and discussed.

  1. X-ray binaries, part 1

    International Nuclear Information System (INIS)

    Hammerschlag-Hensberge, G.C.M.J.

    1977-01-01

    Optical observations of X-ray binaries and their interpretation are described. A number of early-type stars which are identified as companions of X-ray sources are photometrically and spectroscopically observed. The spectra were obtained with the coude spectrograph attached to the 1.5 m telescope of the European Southern Observatory, La Silla, Chile. Registrations of the spectra were made with the Faul-Coradi microphotometer of the Observatory at Utrecht. To study radial velocity variations, the positions of the spectral lines were measured with the Grant comparator of the University of Groningen

  2. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  3. X-ray spectroscopy and X-ray crystallography of metalloenzymes at XFELs

    International Nuclear Information System (INIS)

    Yano, Junko

    2016-01-01

    The ultra-bright femtosecond X-ray pulses provided by X-ray Free Electron Lasers (XFELs) open capabilities for studying the structure and dynamics of a wide variety of biological and inorganic systems beyond what is possible at synchrotron sources. Although the structure and chemistry at the catalytic sites have been studied intensively in both biological and inorganic systems, a full understanding of the atomic-scale chemistry requires new approaches beyond the steady state X-ray crystallography and X-ray spectroscopy at cryogenic temperatures. Following the dynamic changes in the geometric and electronic structure at ambient conditions, while overcoming X-ray damage to the redox active catalytic center, is key for deriving reaction mechanisms. Such studies become possible by using the intense and ultra-short femtosecond X-ray pulses from an XFEL, where sample is probed before it is damaged. We have developed methodology for simultaneously collecting crystallography data and X-ray emission spectra, using an energy dispersive spectrometer at ambient conditions. In addition, we have developed a way to collect metal L-edge data of dilute samples using soft X-rays at XFELs. The advantages and challenges of these methods will be described in this review. (author)

  4. X-ray Optics Development at MSFC

    Science.gov (United States)

    Sharma, Dharma P.

    2017-01-01

    Development of high resolution focusing telescopes has led to a tremendous leap in sensitivity, revolutionizing observational X-ray astronomy. High sensitivity and high spatial resolution X-ray observations have been possible due to use of grazing incidence optics (paraboloid/hyperboloid) coupled with high spatial resolution and high efficiency detectors/imagers. The best X-ray telescope flown so far is mounted onboard Chandra observatory launched on July 23,1999. The telescope has a spatial resolution of 0.5 arc seconds with compatible imaging instruments in the energy range of 0.1 to 10 keV. The Chandra observatory has been responsible for a large number of discoveries and has provided X-ray insights on a large number of celestial objects including stars, supernova remnants, pulsars, magnetars, black holes, active galactic nuclei, galaxies, clusters and our own solar system.

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  6. Diagnostic X-ray spectrometry using a commercial CdZnTe detector

    International Nuclear Information System (INIS)

    Becker, P.H.B.

    1998-01-01

    X ray spectrometry using Ge or Si detectors is an established tool to measure characterization parameters of X-ray beams. This work describes how a commercial CdZnTe was used to perform diagnostic X-ray spectrometry. Spectra were measured for two X-ray machines and compared with similar data found in the literature with an agreement of 2% rms

  7. Generation of x-ray pulses with rapid rise times to pump inner-shell photo-ionized x-ray lasing in carbon at 45 angstrom

    International Nuclear Information System (INIS)

    Moon, S.J.; Eder, D.C.

    1995-01-01

    An investigation of the rapid rise time of x-ray emission from targets heated by an ultrashort-pulse high-intensity optical laser was conducted for use as a pump for inner-shell photo-ionized x-ray lasing. Results of x-ray rise times from instantaneously heated Au rod targets show little benefit for using optical pulse widths less than 30 fs. Gain calculations for inner-shell photo-ionized lasing show that large gains can be obtained for pulse widths between 30 and 100 fs. Calculated spectra, using the hydrodynamic/atomic kinetics code LASNEX, from a 1 J, 65 fs FWHM pulse optical laser incident on a structured Au target gave a gain of 1 1.5 cm -1 in C at 45 angstrom

  8. Experimental versus ab initio x-ray absorption of iron-doped zirconia: Trends in O K -edge spectra as a function of iron doping

    Science.gov (United States)

    Douma, D. H.; Ciprian, R.; Lamperti, A.; Lupo, P.; Cianci, E.; Sangalli, D.; Casoli, F.; Nasi, L.; Albertini, F.; Torelli, P.; Debernardi, A.

    2014-11-01

    We present an experimental study of x-ray absorption near edge structure (XANES) at L2 ,3,M2 ,3, and K edges of, respectively, Fe, Zr, and O in iron-doped zirconia (ZrO2:Fe ) for different Fe dopant concentrations x (from x ˜6 % to x ˜25 % at.) and make the comparison with ab initio simulations at the O K -edge. The x-ray magnetic circular dichroism (XMCD) measurements show no evidence of ferromagnetic (FM) order for all the analyzed samples in agreement with our ab initio simulations, which show an antiferromagnetic (AFM) order. We found that substituting Zr with Fe atoms leads to a radical change in the O K -edge XANES spectrum, especially in the pre-edge region where a pre-edge peak appears. This pre-edge peak is ascribed to dipole transitions from O 1 s to O 2 p states that are hybridized with the unoccupied Fe 3 d states. Both theoretical and experimental results reveal that the intensity of the pre-edge peak increases with Fe concentration, suggesting the increase of unoccupied Fe 3 d states. The increase of Fe concentration increases oxygen vacancies as required for charge neutrality and consequently improves AFM ordering. According to our first-principles calculations, the effect of one Fe atom is mostly localized in the first oxygen shell and vanishes as one moves far from it. Thus the increase of the O K -pre-edge peak with increasing Fe concentration is due to the increase of percentage of oxygen atoms that are near neighbors to Fe atoms.

  9. The properties of cross-correlation and spectra of the low-mass X-ray binary 4U 1608-52

    International Nuclear Information System (INIS)

    Lei, Ya-Juan; Yuan, Hai-Long; Dong, Yi-Qiao; Zhang, Hao-Tong; Zhang, Cheng-Min; Zhao, Yong-Heng; Zhang, Shu; Qu, Jin-Lu; Wang, Ya-Nan; Li, Zhi-Bing

    2014-01-01

    With RXTE data, we analyzed the cross-correlation function between the soft and hard X-rays of the transient atoll source 4U 1608-52. We found anti-correlations in three outbursts occurred in 1998, 2002, and 2010, and we found significant time lags of several hundreds of seconds in the latter two outbursts. Our results show no correlation between the soft and hard X-rays in the extreme island state and a dominated positive correlation in the lower banana state. Anti-correlations are presented at the upper banana state for the outburst of 2010 and at the island and the lower left banana states for the other two outbursts. So far for atoll sources, the cross-correlation has been studied statistically only for 4U 1735-44, where anti-correlations showed up in the upper banana state. Here our investigation on 4U 1608-52 provides a similar result in its 2010 outburst. In addition, we notice that the luminosities in the upper banana of the 1998 and 2002 outbursts are about 1.5 times that of the 2010 outburst whose luminosity in the upper banana is close to that of 4U 1735-44. The results suggest that the states in the color-color diagram of a source could be correlated with the luminosity of the source. A further spectral analysis during the 2010 outburst is also shown, which suggests that the disk can be a little truncated in the upper banana. The feature on the upper banana is similar to the previous results of the flaring branch in Z sources.

  10. Large Charge-Transfer Energy in LiFePO4 Revealed by Full-Multiplet Calculation for the Fe L3 -edge Soft X-ray Emission Spectra.

    Science.gov (United States)

    Asakura, Daisuke; Nanba, Yusuke; Makinose, Yuki; Matsuda, Hirofumi; Glans, Per-Anders; Guo, Jinghua; Hosono, Eiji

    2018-01-31

    We analyzed the Fe 3d electronic structure in LiFePO 4 /FePO 4 (LFP/FP) nanowire with a high cyclability by using soft X-ray emission spectroscopy (XES) combined with configuration-interaction full-multiplet (CIFM) calculation. The ex situ Fe L 2,3 -edge resonant XES (RXES) spectra for LFP and FP are ascribed to oxidation states of Fe 2+ and Fe 3+ , respectively. CIFM calculations for Fe 2+ and Fe 3+ states reproduced the Fe L 3 RXES spectra for LFP and FP, respectively. In the calculations for both states, the charge-transfer energy was considerably larger than those for typical iron oxides, indicating very little electron transfer from the O 2p to Fe 3d orbitals and a weak hybridization on the Fe-O bond during the charge-discharge reactions. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A new type of crystal spectrometer for cosmic X-ray studies

    International Nuclear Information System (INIS)

    Berthelsdorf, R.F.; Mitchell, R.J.; Culhane, J.L.

    1976-01-01

    A crystal spectrometer using a crystal panel curved in two dimensions and a position sensitive proportional counter is described. The instrument uses conical focussing to minimize detector size, and the crystal panel is bent to simultaneously present a range of Bragg angles to incoming X-rays, resulting in a one-to-one correspondence between the energy of a reflected X-ray and its point of incidence on the proportional counter. The advantages of such an instrument are high sensitivity, mechanical simplicity, and the capability of measuring spectra of rapidly varying sources. (Auth.)

  12. X-ray imaging with amorphous selenium: Pulse height measurements of avalanche gain fluctuations

    International Nuclear Information System (INIS)

    Lui, Brian J. M.; Hunt, D. C.; Reznik, A.; Tanioka, K.; Rowlands, J. A.

    2006-01-01

    Avalanche multiplication in amorphous selenium (a-Se) can provide a large, adjustable gain for active matrix flat panel imagers (AMFPI), enabling quantum noise limited x-ray imaging during both radiography and fluoroscopy. In the case of direct conversion AMFPI, the multiplication factor for each x ray is a function of its depth of interaction, and the resulting variations in gain can reduce the detective quantum efficiency (DQE) of the system. An experimental method was developed to measure gain fluctuations by analyzing images of individual x rays that were obtained using a video camera with an a-Se target operated in avalanche mode. Pulse height spectra (PHS) of the charge produced per x ray were recorded for monoenergetic 30.9, 49.4, and 73.8 keV x-ray sources. The rapid initial decay and long tail of each PHS can be explained by a model in which positive charge dominates the initiation of avalanche. The Swank information factor quantifies the effect of gain fluctuation on DQE and was calculated from the PHS. The information factor was found to be 0.5 for a 25 μm a-Se layer with a maximum gain of ∼300. Changing the energy of the incident x ray influenced the range of the primary photoelectron and noticeably affected the tail of the experimental PHS, but did not significantly change the avalanche Swank factor

  13. Pulsating X-ray sources

    International Nuclear Information System (INIS)

    Trumper, J.

    1986-01-01

    The discovery of pulsating X-ray sources in close binary systems was one of the major achievements of the Uhuru satellite. Today one knows about two dozens of these sources with pulsational periods between 69 ms and 835 s. In most cases the X-ray source orbits an early-type star of high mass having a rather large optical luminosity. There are a few exceptions: GX1+4 is associated with a late-type (M6) giant, 4U1616-67 has a comparison of very low mass (≤ 0.1 M/sub sub solar/), and Her X-1 is a borderline case, since its counterpart HZ Her is an A-F star of -- 2/sub sub solar/. It is clear that the X-ray sources in these systems are rotating magnetized neutron stars accreting from their normal companion, probably in most cases via Roche lobe overflow which leads to the formation of an accretion disk. In some cases (e.g. Vela X-1) the accretion proceeds via a stellar wind. Pulsations occur because in the immediate vicinity of the neutron star the matter is funneled by the strong magnetic field onto the polar caps where a hot and very luminous plasma is formed. Typical luminosities are huge, namely of the order of 10/sup 37/ erg/s which are radiated at effective temperatures of -- 10/sup 8/ K. Much has been learned about these systems and about neutron stars from studies of pulse arrival times and source spectra. The author briefly summarizes some of the major results and discusses some very recent results obtained with EXOSAT

  14. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  15. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  16. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  17. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  18. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  19. XMM-Newton X-Ray Observation of Jupiter

    Science.gov (United States)

    Waite, J. Hunter

    2005-01-01

    Soft X-ray emission has been observed from the disk of both Jupiter and Saturn as well as from the auroral regions of these planets. The low-latitude disk emission as observed by ROSAT, the Chandra X-Ray Observatory, and XMM-Newton appears to be uniformly distributed across the disk and to be correlated with solar activity. These characteristics suggest that the disk x-rays are produced by: (1) the elastic scattering of solar X-rays by atmospheric neutrals and (2) the absorption of solar X-rays in the carbon K-shell followed by fluorescent emission. The carbon atoms are found in methane molecules located below the homopause. In this paper we present the results of calculations of the scattering albedo for soft x-rays. We also show the calculated x-ray intensity for a range of atmospheric abundances for Jupiter and Saturn and for a number of solar irradiance spectra. The model calculations are compared with recent x-ray observations of Jupiter and Saturn. We conclude that the emission of soft x-rays from the disks of Jupiter and Saturn can be largely explained by the scattering and fluorescence of soft x-rays. We suggest that measured x-ray intensities from the disk regions of Jupiter

  20. X-ray diffraction imaging of material microstructures

    KAUST Repository

    Varga, Laszlo

    2016-10-20

    Various examples are provided for x-ray imaging of the microstructure of materials. In one example, a system for non-destructive material testing includes an x-ray source configured to generate a beam spot on a test item; a grid detector configured to receive x- rays diffracted from the test object; and a computing device configured to determine a microstructure image based at least in part upon a diffraction pattern of the x-rays diffracted from the test object. In another example, a method for determining a microstructure of a material includes illuminating a beam spot on the material with a beam of incident x-rays; detecting, with a grid detector, x-rays diffracted from the material; and determining, by a computing device, a microstructure image based at least in part upon a diffraction pattern of the x-rays diffracted from the material.

  1. A Test Facility For Astronomical X-Ray Optics

    DEFF Research Database (Denmark)

    Lewis, R. A.; Bordas, J.; Christensen, Finn Erland

    1989-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earths atmosphere. These devices require a large collection aperture and the imaging of an x-ray source which is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions, however the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron Radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area whilst still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes is described below. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  2. Producing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Jung, R.G.; Applebaum, D.C.; Fairand, B.P.; Gallagher, W.J.

    1977-01-01

    A method of producing x-rays by directing radiant energy from a laser onto a target is described. Conversion efficiency of at least about 3 percent is obtained by providing the radiant energy in a low-power precursor pulse of approximately uniform effective intensity focused onto the surface of the target for about 1 to 30 nanoseconds so as to generate an expanding unconfined coronal plasma having less than normal solid density throughout and comprising a low-density (underdense) region wherein the plasma frequency is less than the laser radiation frequency and a higher-density (overdense) region wherein the plasma frequency is greater than the laser radiation frequency and, about 1 to 30 nanoseconds after the precursor pulse strikes the target, a higher-power main pulse focused onto the plasma for about 10 -3 to 30 nanoseconds and having such power density and total energy that the radiant energy is absorbed in the underdense region and conducted into the overdense region to heat it and thus to produce x-rays therefrom with the plasma remaining substantially below normal solid density and thus facilitating the substantial emission of x-rays in the form of spectral lines arising from nonequilibrium ionization states

  3. Synthesis, spectra and X-ray crystallography of dipyridin-2-ylmethanone oxime and its CuX2(oxime)2 complexes: Thermal, Hirshfeld surface and DFT analysis

    Science.gov (United States)

    Warad, Ismail; Abdoh, Muneer; Al Ali, Anas; Shivalingegowda, Naveen; Kumara, Karthik; Zarrouk, Abdelkader; Lokanath, Neartur Krishnappagowda

    2018-02-01

    Dipyridin-2-ylmethanone oxime (C11H9N3O), was prepared using di-2-pyridyl ketone. The oxime ligand and its neutral CuX2 (oxime)2 (X = Cl or Br) complexes have been identified with the aid of several spectroscopic techniques such as: IR, EI-MS, EA, UV-visible, TG, 1H-NMR and finally the structure of the free oxime ligand was confirmed by X-ray diffraction studies. The oxime crystallizes in the monoclinic space group P21/c, with cell parameters a = 8.8811 (8) Å, b = 10.6362 (8) Å, c = 11.2050 (8) Å, β = 109.085 (4) º, V = 1000.26 (14) Å3 and Z = 4. The molecular conformation is stabilized by a strong intramolecular Osbnd H⋯N hydrogen bonding between the hydroxyl group of the oxime moiety and the nitrogen of the pyridine ring. Since the oxime structure was solved by XRD, the ligand structure parameters like bond length and angles were compared to the DFT computed one, the UV-visible to TD-SCF and Hirshfeld surface to MEP analysis.

  4. Cation profiling of passive films on stainless steel formed in sulphuric and acetic acid by deconvolution of angle-resolved X-ray photoelectron spectra

    Energy Technology Data Exchange (ETDEWEB)

    Högström, Jonas, E-mail: jhogstrom@gmail.com; Fredriksson, Wendy, E-mail: wendy.fredriksson@kemi.uu.se; Edstrom, Kristina, E-mail: kristina.edstrom@kemi.uu.se; Björefors, Fredrik, E-mail: fredrik.bjorefors@kemi.uu.se; Nyholm, Leif, E-mail: leif.nyholm@kemi.uu.se; Olsson, Claes-Olof A., E-mail: drclabbe@kth.se

    2013-11-01

    An approach for determining depth gradients of metal-ion concentrations in passive films on stainless steel using angle-resolved X-ray photoelectron spectroscopy (ARXPS) is described. The iterative method, which is based on analyses of the oxidised metal peaks, provides increased precision and hence allows faster ARXPS measurements to be carried out. The method was used to determine the concentration depth profiles for molybdenum, iron and chromium in passive films on 316L/EN 1.4432 stainless steel samples oxidised in 0.5 M H{sub 2}SO{sub 4} and acetic acid diluted with 0.02 M Na{sub 2}B{sub 4}O{sub 7} · 10H{sub 2}O and 1 M H{sub 2}O, respectively. The molybdenum concentration in the film is pin-pointed to the oxide/metal interface and the films also contained an iron-ion-enriched surface layer and a chromium-ion-dominated middle layer. Although films of similar composition and thickness (i.e., about 2 nm) were formed in the two electrolytes, the corrosion currents were found to be three orders of magnitude larger in the acetic acid solution. The differences in the layer composition, found for the two electrolytes as well as different oxidation conditions, can be explained based on the oxidation potentials of the metals and the dissolution rates of the different metal ions.

  5. Signature of the hydrogen-bonded environment of liquid water in X-ray emission spectra from first-principles calculations

    Science.gov (United States)

    Shen, Huaze; Chen, Mohan; Sun, Zhaoru; Xu, Limei; Wang, Enge; Wu, Xifan

    2018-02-01

    Based on ab initio molecular dynamics simulations and density functional theory, we performed a systematic theoretical study to elucidate the correlation between the H-bonded environment and Xray emission spectra of liquid water. The spectra generated from excited water molecules embedded in an intact H-bonded environment yield broader spectral peaks and a larger spectral range than the spectra generated from water molecules in a broken H-bonded environment. Such differences are caused by the local electronic structures on the excited water molecules within the core-hole lifetime that evolve differently through the rearrangement of neighboring water molecules in different H-bonded environments.

  6. X-ray spectra of He-like ions of Ga and Ge, excited in the low-inductance spark plasma

    International Nuclear Information System (INIS)

    Aglitsky, E.V.; Antsiferov, P.S.; Panin, A.M.

    1984-01-01

    The spectra of Ga XXX and Ge XXXI ions in the interval 1.2-1.4 A excited in the low-inductance vacuum spark plasma have been obtained for the first time. The resonance line 1s 2 -1s2p of Ga XXX and Ge XXXI and a group of satellites, corresponding to transitions in Ga XXIX and Ge XXX can be seen distinctly in the spectra. The spectra were obtained by an electronic-optical image-intensifier tube for one discharge. (orig.)

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x- ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... shades of gray and air appears black. Until recently, x-ray images were maintained on large film ... assist you in finding the most comfortable position possible that still ensures x-ray image quality. top ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  15. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... image on photographic film or a special detector. Different parts of the body absorb the x-rays ... process is repeated. Two or three images (from different angles) will typically be taken. An x-ray ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...