WorldWideScience

Sample records for incident positron beam

  1. A Southern African positron beam

    International Nuclear Information System (INIS)

    Britton, D.T.; Haerting, M.; Teemane, M.R.B.; Mills, S.; Nortier, F.M.; Van der Walt, T.N.

    1997-01-01

    The first stage of a state of the art positron beam, being constructed at the University of Cape Town, is currently being brought into operation. This is the first positron beam on the African continent, as well as being the first positron beam dedicated to solid and surface studies in the southern hemisphere. The project also contains a high proportion of local development, including the encapsulated 22 Na positron source developed by our collaboration. Novel features in the design include a purely magnetic in-line deflector, working in the solenoidal guiding field, to eliminate unmoderated positrons and block the direct line of sight to the source. A combined magnetic projector and single pole probe forming lens is being implemented in the second phase of construction to achieve a spot size of 10 μm without remoderation

  2. Depth profiling of aluminium metal using slow positron beam ...

    African Journals Online (AJOL)

    Slow positron beam Doppler-broadening technique was used to study depth profiling of aluminium metals sample. The variation of the line-shape parameters with incident positron energy was studied. Also, the depth profile of the S parameter was investigated. The positron implantation profile and backscattering fraction for ...

  3. Micrometer positron beam characterization at the Scanning Positron Microscope Interface

    Science.gov (United States)

    Mitteneder, J.; Dickmann, M.; Kögel, G.; Egger, W.; Sperr, P.; Dollinger, G.

    2017-01-01

    For the investigation of inhomogeneous defect distributions the Scanning Positron Microscope (SPM) of the Universität der Bundeswehr München provides a pulsed positron beam with a diameter of about 1 µm and a time resolution of 250 ps (FWHM). To increase the count-rate the SPM is currently transferred to the intense positron source NEPOMUC. To connect the SPM to the NEPOMUC source a special interface was build, which transforms the NEPOMUC beam to the requirements of the SPM. In this contribution we will give an overview of the SPM interface, and its performance. The beam is characterized at the finale stage of the interface, the positron elevator, where the potential energy of the beam is increased, without altering other beam parameters. From our measurements we are able to predict the performance of the SPM at NEPOMUC. In future position resolved measurements will be possible with an improved spatial resolution of about 0.3 µm and an event rate of about 3.7 kHz.

  4. Slow positron beam at the JINR, Dubna

    Directory of Open Access Journals (Sweden)

    Horodek Paweł

    2015-12-01

    Full Text Available The Low Energy Positron Toroidal Accumulator (LEPTA at the Joint Institute for Nuclear Research (JINR proposed for generation of positronium in flight has been adopted for positron annihilation spectroscopy (PAS. The positron injector generates continuous slow positron beam with positron energy range between 50 eV and 35 keV. The radioactive 22Na isotope is used. In distinction to popular tungsten foil, here the solid neon is used as moderator. It allows to obtain the beam intensity of about 105 e+/s width energy spectrum characterized by full width at half maximum (FWHM of 3.4 eV and a tail to lower energies of about 30 eV. The paper covers the characteristic of variable energy positron beam at the LEPTA facility: parameters, the rule of moderation, scheme of injector, and transportation of positrons into the sample chamber. Recent status of the project and its development in the field of PAS is discussed. As an example, the measurement of the positron diffusion length in pure iron is demonstrated.

  5. Experimentation with low-energy positron beams

    International Nuclear Information System (INIS)

    Mills, A.P. Jr.

    1983-01-01

    The capability of studying the interactions of positrons with surfaces has recently been exploited by using ultra-high-vacuum techniques. The result has been a new understanding of how positrons interact with surfaces and because of this we are now able to make much stronger fluxes of slow positrons. The higher beam strengths in turn are opening up new possibilities for experimentation on surfaces and solids and for studying the atomic physics of positronium and positron-molecule scattering at low energies. The lectures are intended to review some of the history of this subject and to outline the present state of our knowledge of experimentation with low-energy positron beams. (orig./TW)

  6. Polymeric membrane studied using slow positron beam

    International Nuclear Information System (INIS)

    Hung, W.-S.; Lo, C.-H.; Cheng, M.-L.; Chen Hongmin; Liu Guang; Chakka, Lakshmi; Nanda, D.; Tung, K.-L.; Huang, S.-H.; Lee, Kueir-Rarn; Lai, J.-Y.; Sun Yiming; Yu Changcheng; Zhang Renwu; Jean, Y.C.

    2008-01-01

    A radioisotope slow positron beam has been built at the Chung Yuan Christian University in Taiwan for the research and development in membrane science and technology. Doppler broadening energy spectra and positron annihilation lifetime have been measured as a function of positron energy up to 30 keV in a polyamide membrane prepared by the interfacial polymerization between triethylenetetraamine (TETA) and trimesoyl chloride (TMC) on modified porous polyacrylonitrile (PAN) asymmetric membrane. The multilayer structures and free-volume depth profile for this asymmetric membrane system are obtained. Positron annihilation spectroscopy coupled with a slow beam could provide new information about size selectivity of transporting molecules and guidance for molecular designs in polymeric membranes

  7. Production of slow-positron beams with an electron linac

    International Nuclear Information System (INIS)

    Howell, R.H.; Alvarez, R.A.; Stanek, M.

    1982-01-01

    Intense, pulsed beams of low-energy positrons have been produced by a high-energy beam from an electron linac. The production efficiency for low-energy positrons has been determined for electrons with 60 to 120 MeV energy, low-energy positron beams from a linac can be of much higher intensity than those beams currently derived from radioactive sources

  8. Positron beam production with a deuteron accelerator

    CERN Document Server

    Cassidy, D B; Shefer, R E; Klinkowstein, R; Hughey, B J

    2002-01-01

    A graphite target was bombarded with 1.5 MeV deuterons, producing the isotope sup 1 sup 3 N, which is a positron emitter. Using the activated material a slow positron beam with an intensity of 0.7 (0.14)x10 sup 5 s sup - sup 1 was produced. A (saturated) sup 1 sup 3 N yield of 63 (11) MBq/mu A was observed, with 1.5 MeV deuterons, which is consistent with previous calculations and experiments. Our results show that, with the method we outline, positron beams with an average intensity of up to 1x10 sup 8 s sup - sup 1 may be produced.

  9. Grazing incidence beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.

    1985-01-01

    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  10. Positron lifetime measurements and positron-annihilation induced auger electron spectroscpy using slow positron beams; Teisoku yodenshi bimu wo mochiita yodenshi jumyo sokutei oyobi yodenshi shometsu reiki oje denshi bunko

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, R. [Electrotechnical Lab., Tsukuba (Japan)

    1996-02-20

    Slow positron beam with less than several eV can be controlled freely such as accelerating, throttling the beam size, shortening the pulse or making pulse with short time width and so forth. These low positron beams are applied to various measurements like Doppler broadening measurement of annihilation {gamma} rays or lifetime measurement of positron, and secondary particle measurements using positron microscope, positron electron ray diffraction, flight time method and so forth. In particular, these recent years, high intensity slow positron beams were possible using accelerators like electron linac and its application is increasing. In this report, pulse shortening method for high intensity slow positron beam, and incidence energy variable positron lifetime measurement method using this slow pulsed beam and flight time type positron-annihilation-induced auger electron spectroscopy are outlined. In future, these measurements can be possible to carry out with high resolution and also with high counting rate if higher intensity monochromatic excellent positron beam than present one is produced. 31 refs., 5 figs.

  11. Generation of a high-brightness pulsed positron beam for the Munich scanning positron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Piochacz, Christian

    2009-11-20

    Within the present work the prerequisites for the operation of the Munich scanning positron microscope (SPM) at the high intense neutron induced positron source Munich (NEPOMUC) were established. This was accomplished in two steps: Firstly, a re-moderation device was installed at the positron beam facility NEPOMUC, which enhances the brightness of the positron beam for all connected experiments. The second step was the design, set up and initial operation of the SPM interface for the high efficient conversion of the continuous beam into a bunched beam. The in-pile positron source NEPOMUC creates a positron beam with a diameter of typically 7 mm, a kinetic energy of 1 keV and an energy spread of 50 eV. The NEPOMUC re-moderator generates from this beam a low energy positron beam (20 - 200 eV) with a diameter of less than 2 mm and an energy spread well below 2.5 eV. This was achieved with an excellent total efficiency of 6.55{+-}0.25 %. The re-moderator was not only the rst step to implement the SPM at NEPOMUc, it enables also the operation of the pulsed low energy positron beam system (PLEPS). Within the present work, at this spectrometer rst positron lifetime measurements were performed, which revealed the defect types of an ion irradiated uranium molybdenum alloy. Moreover, the instruments which were already connected to the positron beam facility bene ts considerably of the high brightness enhancement. In the new SPM interface an additional re-moderation stage enhances the brightness of the beam even more and will enable positron lifetime measurements at the SPM with a lateral resolution below 1 {mu}m. The efficiency of the re-moderation process in this second stage was 24.5{+-}4.5 %. In order to convert high efficiently the continuous positron beam into a pulsed beam with a repetition rate of 50 MHz and a pulse duration of less than 50 ps, a sub-harmonic pre-bucher was combined with two sine wave bunchers. Furthermore, the additional re-moderation stage of the

  12. Generation of a high-brightness pulsed positron beam for the Munich scanning positron microscope

    International Nuclear Information System (INIS)

    Piochacz, Christian

    2009-01-01

    Within the present work the prerequisites for the operation of the Munich scanning positron microscope (SPM) at the high intense neutron induced positron source Munich (NEPOMUC) were established. This was accomplished in two steps: Firstly, a re-moderation device was installed at the positron beam facility NEPOMUC, which enhances the brightness of the positron beam for all connected experiments. The second step was the design, set up and initial operation of the SPM interface for the high efficient conversion of the continuous beam into a bunched beam. The in-pile positron source NEPOMUC creates a positron beam with a diameter of typically 7 mm, a kinetic energy of 1 keV and an energy spread of 50 eV. The NEPOMUC re-moderator generates from this beam a low energy positron beam (20 - 200 eV) with a diameter of less than 2 mm and an energy spread well below 2.5 eV. This was achieved with an excellent total efficiency of 6.55±0.25 %. The re-moderator was not only the rst step to implement the SPM at NEPOMUc, it enables also the operation of the pulsed low energy positron beam system (PLEPS). Within the present work, at this spectrometer rst positron lifetime measurements were performed, which revealed the defect types of an ion irradiated uranium molybdenum alloy. Moreover, the instruments which were already connected to the positron beam facility bene ts considerably of the high brightness enhancement. In the new SPM interface an additional re-moderation stage enhances the brightness of the beam even more and will enable positron lifetime measurements at the SPM with a lateral resolution below 1 μm. The efficiency of the re-moderation process in this second stage was 24.5±4.5 %. In order to convert high efficiently the continuous positron beam into a pulsed beam with a repetition rate of 50 MHz and a pulse duration of less than 50 ps, a sub-harmonic pre-bucher was combined with two sine wave bunchers. Furthermore, the additional re-moderation stage of the SPM

  13. Intense positron beam and its application to surface science

    International Nuclear Information System (INIS)

    Ito, Y.; Hirose, M.; Kanazawa, I.; Sueoka, O.; Takamura, S.; Okada, S.

    1992-01-01

    Intense pulsed slow positron beam has been produced using the 100 MeV electron LINAC of JAERI · Tokai. In order to use the beam for surface studies such as positron diffraction and positron microscopy, it was transferred from the solenoid magnetic field to field free region and then was brightness-enhanced. The beam size was reduced from 10 mmφ (in the magnetic field) to 0.5 mmφ after two stages of re-moderation. Using the intense brightness-enhanced positron beam we have observed for the first time RHEPD (Reflection High-Energy Positron Diffraction) patterns. A design of re-emission positron microscopy is also described. (author)

  14. Development of pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Masaki; Kawasuso, Atsuo; Itoh, Hisayoshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Masuno, Shinichi [Mitsubishi Electric Engineering Company Limited, Tokyo (Japan); Hirano, Takeshi; Kondo, Masakazu [Mitsubishi Electric Corporation, Tokyo (Japan); Okada, Sohei [Japan Atomic Energy Research Inst., Kashiwa, Chiba (Japan)

    2003-03-01

    We have developed a high-energy pulsed positron beam apparatus employing an RF acceleration method in order to apply positron annihilation lifetime spectroscopy (PALS) studies to bulk materials at high-temperature and/or high-pressure conditions. This apparatus contains a slow positron pulsing system and a radio frequency (RF) acceleration cavity. Performance tests were carried out using electron and positron beams. Beam energy ({approx}1 MeV), s beam size ({phi} 0.5 mm) and a beam transmission are as good as expectations of machine design. In the time structures of accelerated beam, satellite pulses superposed on broad pulses were observed. In order to make PULS measurement using RF cavity, it is important to form a high quality beam with single fine pulses by refine of the bunching system and the RF source driven with high duty ratio. (author)

  15. Characterization of the surface layer of LB-films using a slow positron beam

    CERN Document Server

    Koshimizu, M; Ishigure, K; Iwai, T; Shibata, H; Ito, Y

    2000-01-01

    Langmuir-Blodgett films were studied using a variable energy slow-positron beam. We measured the energy spectra of positron annihilation radiation for Cd and Mg eicosano id films and obtained the V- and S-parameters as a function of the incident positron energy, E. In the V-E curves of Cd eicosano id films, there were dips at the positron energy whose mean implantation depth corresponding to the first and second Cd sup sup 2 sup sup + layers from the surface. These dips are interpreted as the result of inhibition of Ps formation by the Cd sup sup 2 sup sup + ions. The S-parameter was found to be sensitive to chemical composition of the film and also to possible structural change due to heat treatment. Our results suggest that positron beams provide valuable information about the microstructure of the Langmuir-Blodgett films.

  16. Status of positron beams for dark photons experiments

    Directory of Open Access Journals (Sweden)

    Valente Paolo

    2017-01-01

    Full Text Available High energy positron beams are an important tool for fixed-target experiments searching for new particles produced in the annihilation on atomic electrons of a target. The status of existing or planned infrastructures is reviewed.

  17. Construction of a pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  18. PEPPo: Using a Polarized Electron Beam to Produce Polarized Positrons

    Energy Technology Data Exchange (ETDEWEB)

    Adeyemi, Adeleke H. [Hampton Univ., Hampton, VA (United States); et al.

    2015-09-01

    Polarized positron beams have been identified as either an essential or a significant ingredient for the experimental program of both the present and next generation of lepton accelerators (JLab, Super KEK B, ILC, CLIC). An experiment demonstrating a new method for producing polarized positrons has been performed at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. The PEPPo (Polarized Electrons for Polarized Positrons) concept relies on the production of polarized e⁻/e⁺ pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. PEPPo demonstrated the effective transfer of spin-polarization of an 8.2 MeV/c polarized (P~85%) electron beam to positrons produced in varying thickness tungsten production targets, and collected and measured in the range of 3.1 to 6.2 MeV/c. In comparison to other methods this technique reveals a new pathway for producing either high-energy or thermal polarized positron beams using a relatively low polarized electron beam energy (~10MeV) .This presentation will describe the PEPPo concept, the motivations of the experiment and high positron polarization achieved.

  19. Testing of a nuclear-reactor-based positron beam

    International Nuclear Information System (INIS)

    Van Veen, A.; Labohm, F.; Schut, H.; De Roode, J.; Heijenga, T.; Mijnarends, P.E.

    1997-01-01

    This paper describes the testing of a positron beam which is primarily based on copper activation near the core of a nuclear reactor and extraction of the positrons through a beam guide tube. An out-of-core test with a 22 Na source and an in-core test with the reactor at reduced power have been performed. Both tests indicated a high reflectivity of moderated positrons at the tungsten surfaces of the moderation discs which enhanced the expected yield. Secondary electrons generated in the source materials during the in-core test caused electrical field distortions in the electrode system of the system by charging of the insulators. At 100 kW reactor power during one hour, positrons were observed with an intensity of 4.4x10 4 e + s -1 of which 90% was due to positrons created by pair formation and 10% by copper activation

  20. Improving depth resolutions in positron beam spectroscopy by concurrent ion-beam sputtering

    Science.gov (United States)

    John, Marco; Dalla, Ayham; Ibrahim, Alaa M.; Anwand, Wolfgang; Wagner, Andreas; Böttger, Roman; Krause-Rehberg, Reinhard

    2018-05-01

    The depth resolution of mono-energetic positron annihilation spectroscopy using a positron beam is shown to improve by concurrently removing the sample surface layer during positron beam spectroscopy. During ion-beam sputtering with argon ions, Doppler-broadening spectroscopy is performed with energies ranging from 3 keV to 5 keV allowing for high-resolution defect studies just below the sputtered surface. With this technique, significantly improved depth resolutions could be obtained even at larger depths when compared to standard positron beam experiments which suffer from extended positron implantation profiles at higher positron energies. Our results show that it is possible to investigate layered structures with a thickness of about 4 microns with significantly improved depth resolution. We demonstrated that a purposely generated ion-beam induced defect profile in a silicon sample could be resolved employing the new technique. A depth resolution of less than 100 nm could be reached.

  1. Recent progress in tailoring trap-based positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Natisin, M. R.; Hurst, N. C.; Danielson, J. R.; Surko, C. M. [Physics Department, University of California, San Diego La Jolla CA 92093-0319 (United States)

    2013-03-19

    Recent progress is described to implement two approaches to specially tailor trap-based positron beams. Experiments and simulations are presented to understand the limits on the energy spread and pulse duration of positron beams extracted from a Penning-Malmberg (PM) trap after the particles have been buffer-gas cooled (or heated) in the range of temperatures 1000 {>=} T {>=} 300 K. These simulations are also used to predict beam performance for cryogenically cooled positrons. Experiments and simulations are also presented to understand the properties of beams formed when plasmas are tailored in a PM trap in a 5 tesla magnetic field, then non-adiabatically extracted from the field using a specially designed high-permeability grid to create a new class of electrostatically guided beams.

  2. Plasma Wakefield Acceleration of an Intense Positron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Blue, B

    2004-04-21

    The Plasma Wakefield Accelerator (PWFA) is an advanced accelerator concept which possess a high acceleration gradient and a long interaction length for accelerating both electrons and positrons. Although electron beam-plasma interactions have been extensively studied in connection with the PWFA, very little work has been done with respect to positron beam-plasma interactions. This dissertation addresses three issues relating to a positron beam driven plasma wakefield accelerator. These issues are (a) the suitability of employing a positron drive bunch to excite a wake; (b) the transverse stability of the drive bunch; and (c) the acceleration of positrons by the plasma wake that is driven by a positron bunch. These three issues are explored first through computer simulations and then through experiments. First, a theory is developed on the impulse response of plasma to a short drive beam which is valid for small perturbations to the plasma density. This is followed up with several particle-in-cell (PIC) simulations which study the experimental parameter (bunch length, charge, radius, and plasma density) range. Next, the experimental setup is described with an emphasis on the equipment used to measure the longitudinal energy variations of the positron beam. Then, the transverse dynamics of a positron beam in a plasma are described. Special attention is given to the way focusing, defocusing, and a tilted beam would appear to be energy variations as viewed on our diagnostics. Finally, the energy dynamics imparted on a 730 {micro}m long, 40 {micro}m radius, 28.5 GeV positron beam with 1.2 x 10{sup 10} particles in a 1.4 meter long 0-2 x 10{sup 14} e{sup -}/cm{sup 3} plasma is described. First the energy loss was measured as a function of plasma density and the measurements are compared to theory. Then, an energy gain of 79 {+-} 15 MeV is shown. This is the first demonstration of energy gain of a positron beam in a plasma and it is in good agreement with the predictions

  3. Proposal for an intense slow positron beam facility at PSI

    International Nuclear Information System (INIS)

    Waeber, W.B.; Taqqu, D.; Zimmermann, U.; Solt, G.

    1990-05-01

    In the domain of condensed matter physics and materials sciences monoenergetic slow positrons in the form of highest intensity beams are demonstrated to be extreamly useful and considered to be highly needed. This conclusion has been reached and the scientific relevance of the positron probe has been highlighted at an international workshop in November 1989 at PSI, where the state of the art and the international situation on slow positron beams, the fields of application of intense beams and the technical possibilities at PSI for installing intense positron sources have been evaluated. The participants agreed that a high intensity beam as a large-scale user facility at PSI would serve fundamental and applied research. The analysis of responses given by numerous members of a widespread positron community has revealed a large research potential in the domain of solid-state physics, atomic physics and surface, thin-film and defect physics, for example. The excellent feature of slow positron beams to be a suitable probe also for lattice defects near surfaces or interfaces has attracted the interest not only of science but also of industry.In this report we propose the installation of an intense slow positron beam facility at PSI including various beam lines of different qualities and based on the Cyclotron production of β + emitting source material and on a highest efficiency moderation scheme which exceeds standard moderation efficiencies by two orders of magnitude. In its proposed form, the project is estimated to be realizable in the nineties and costs will amount to between 15 and 20 MSFr. (author) 10 figs., 6 tabs., 78 refs

  4. Variable-energy positron-beam studies of Ni implanted with He

    International Nuclear Information System (INIS)

    Lynn, K.G.; Chen, D.M.; Nielsen, B.; Pareja, R.; Myers, S.

    1986-01-01

    Variable-energy positron-beam studies have been made on well-annealed polycrystalline Ni samples implanted with 30-, 90-, and 180-keV 4 He ions. The positron-annihilation characteristics were measured with a solid-state Ge detector at a number of different incident-positron energies and after isochronal annealing at various temperatures. The Doppler broadening of the annihilation photons was found to be strongly influenced by the 4 He implantations. The data indicate that trapping of the positrons occurred predominantly at small He bubbles. The variation of the broadening with incident-positron energy was sensitive to the depth distribution of the traps. A diffusion model assuming a square concentration-defect profile was developed and analytically fitted to the parametrized momentum data. These fitted results were compared to Monte Carlo range calculations for 4 He in Ni, and fairly good agreement was found. This investigation demonstrates the capabilities of positron annihilation for nondestructive depth profiling in ion-implanted systems. In addition, it establishes parallels between the trapping behavior of positrons and that reported elsewhere for hydrogen, thereby augmenting the present level of understanding of the technologically important trapping of hydrogen by the bubbles

  5. Applications and advances of positron beam spectroscopy: appendix a

    Energy Technology Data Exchange (ETDEWEB)

    Howell, R. H., LLNL

    1997-11-05

    Over 50 scientists from DOE-DP, DOE-ER, the national laboratories, academia and industry attended a workshop held on November 5-7, 1997 at Lawrence Livermore National Laboratory jointly sponsored by the DOE-Division of Materials Science, The Materials Research Institute at LLNL and the University of California Presidents Office. Workshop participants were charged to address two questions: Is there a need for a national center for materials analysis using positron techniques and can the capabilities at Lawrence Livermore National Laboratory serve this need. To demonstrate the need for a national center the workshop participants discussed the technical advantages enabled by high positron currents and advanced measurement techniques, the role that these techniques will play in materials analysis and the demand for the data. There were general discussions lead by review talks on positron analysis techniques, and their applications to problems in semiconductors, polymers and composites, metals and engineering materials, surface analysis and advanced techniques. These were followed by focus sessions on positron analysis opportunities in these same areas. Livermore now leads the world in materials analysis capabilities by positrons due to developments in response to demands of science based stockpile stewardship. There was a detailed discussion of the LLNL capabilities and a tour of the facilities. The Livermore facilities now include the worlds highest current beam of keV positrons, a scanning pulsed positron microprobe under development capable of three dimensional maps of defect size and concentration, an MeV positron beam for defect analysis of large samples, and electron momentum spectroscopy by positrons. This document is a supplement to the written summary report. It contains a complete schedule, list of attendees and the vuegraphs for the presentations in the review and focus sessions.

  6. Spin-polarization of an electro-static positron beam

    International Nuclear Information System (INIS)

    Kawasuso, A.; Maekawa, M.

    2008-01-01

    We constructed an electro-static positron beam apparatus. We fabricated a simple spin-polarimeter composed of a permanent magnet with a surface magnetic field of 0.65 T and an iron pole piece. The longitudinal spin-polarization of the positron beam was determined to be 0.3 by analyzing the magnetic field dependence of the Doppler broadening of annihilation radiation from a fused silica specimen. The effect of spin rotation was examined using an iron poly-crystal and a simple E x B filter

  7. Defects introduced by Ar plasma exposure in GaAs probed by monoenergetic positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kawano, Takao; Wada, Kazumi; Nakanishi, Hideo

    1994-10-01

    Ar-plasma-induced defects in n-type GaAs were probed by a monoenergetic positron beam. The depth distribution of the defects was obtained from measurements of Doppler broadening profiles of the annihilation radiation as a function of incident positron energy. The damaged layer induced by the exposure was found to extend far beyond the stopping range of Ar ions, and the dominant defects were identified as interstitial-type defects. After 100degC annealing, such defects were annealed. Instead, vacancy-type defects were found to be the dominant defects in the subsurface region. (author).

  8. The positron beam at the stuttgart pelletron accelerator and its applications to β +γ positron lifetime measurements

    Science.gov (United States)

    Bauer, W.; Maier, K.; Major, J.; Schaefer, H.-E.; Seeger, A.; Carstanjen, H.-D.; Decker, W.; Diehl, J.; Stoll, H.

    1987-08-01

    A slow-positron source has been installed in the therminal of an electrostatic 6.5 MeV accelerator and provides a monoenergetic positron beam in the few-MeV range. It will be used to operate a “fast” positron lifetime spectrometer based on β + γ coincidences. The properties of the beam, the expected performance of the spectrometer, its advantages over conventional γγ lifetime measurements, a number of intended applications, as well as recent positron-electron scattering experiments and plans for positron channelling and channelling-radiation studies are outlined.

  9. Renormalization theory of beam-beam interaction in electron-positron colliders

    International Nuclear Information System (INIS)

    Chin, Y.H.

    1989-07-01

    This note is devoted to explaining the essence of the renormalization theory of beam-beam interaction for carrying out analytical calculations of equilibrium particle distributions in electron-positron colliding beam storage rings. Some new numerical examples are presented such as for betatron tune dependence of the rms beam size. The theory shows reasonably good agreements with the results of computer simulations. 5 refs., 6 figs

  10. Production and application of pulsed slow-positron beam using an electron LINAC

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Tetsuo; Suzuki, Ryoichi; Ohdaira, Toshiyuki; Mikado, Tomohisa [Electrotechnical Lab., Tsukuba, Ibaraki (Japan); Kobayashi, Yoshinori

    1997-03-01

    Slow-positron beam is quite useful for non-destructive material research. At the Electrotechnical Laboratory (ETL), an intense slow positron beam line by exploiting an electron linac has been constructed in order to carry out various experiments on material analysis. The beam line can generates pulsed positron beams of variable energy and of variable pulse period. Many experiments have been carried out so far with the beam line. In this paper, various capability of the intense pulsed positron beam is presented, based on the experience at the ETL, and the prospect for the future is discussed. (author)

  11. Positron beam lifetime spectroscopy of atomic scale defect distributions in bulk and microscopic volumes

    International Nuclear Information System (INIS)

    Howell, R.H.; Cowan, T.E.; Hartley, J.; Sterne, P.; Brown, B.

    1996-05-01

    We are developing a defect analysis capability based on two positron beam lifetime spectrometers: the first is based on a 3 MeV electrostatic accelerator and the second on our high current linac beam. The high energy beam lifetime spectrometer is operational and positron lifetime analysis is performed with a 3 MeV positron beam on thick samples. It is being used for bulk sample analysis and analysis of samples encapsulated in controlled environments for insitu measurements. A second, low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopies is under development at the LLNL high current positron source. This beam will enable defect specific, 3-D maps of defect concentration with sub-micron location resolution and when coupled with first principles calculations of defect specific positron lifetimes it will enable new levels of defect concentration mapping and defect identification

  12. TRISTAN, electron-positron colliding beam project

    International Nuclear Information System (INIS)

    1987-03-01

    In this report e + e - colliding beam program which is now referred to as TRISTAN Project will be described. A brief chronology and outline of TRISTAN Project is given in Chapter 1. Chapter 2 of this article gives a discussion of physics objectives at TRISTAN. Chapter 3 treats the overall description of the accelerators. Chapter 4 describes design of each of the accelerator systems. In Chapter 5, detector facilities are discussed in some detail. A description of accelerator tunnels, experimental areas, and utilities are given in Chapter 6. In the Appendix, the publications on the TRISTAN Project are listed. (author)

  13. Automatically controlled correlation spectrometer with a bounded positron beam

    International Nuclear Information System (INIS)

    Grone, R.

    1991-01-01

    The spectrometer consists of a frame which carries a fixed arm with collimating slits and a pair of scintillator units positioned against each other, and a movable arm which moves in the horizontal plane and also holds collimating slits and two scintillator units positioned against each other. In the centre of the frame is a shielding cover with a chamber housing a slidable positron source. The end of the cover is fitted with a replaceable diaphragm against which a sample holder is positioned. The chamber with a bounded positron beam can be employed to measure a sample at preselected sites and thus gain information concerning various parts of the sample surface and its inhomogeneity. (M.D.). 3 figs

  14. Study of ion beam induced depolymerization using positron annihilation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Puglisi, O. E-mail: opuglisi@dipchi.unict.it; Fragala, M.E.; Lynn, K.G.; Petkov, M.; Weber, M.; Somoza, A.; Dupasquier, A.; Quasso, F

    2001-04-01

    Ion beam induced depolymerization of polymers is a special class of ion beam induced chemical reaction which gives rise to catastrophic 'unzipping' of macromolecules with production of large amounts of the monomer, of the order of many hundreds monomer molecules per each macromolecule. The possible modification of the density at microscopic level prompted us to undertake a study of this effect utilizing positron annihilation techniques in Poly(methylmethacrylate) (PMMA) before and after bombardment with He{sup +} 300 keV ions at 200 deg. C. Preliminary results shown here indicate that before bombardment there is a reproducible dependence of nano-hole distribution on the sample history. Moreover at 200 deg. C we do not detect formation of new cavities as a consequence of the strong depolymerization that occurs under the ion beam. The possible correlation of these findings with transport properties of PMMA at temperature higher than the glass transition temperature will be discussed.

  15. Imaging instrument for positron emitting heavy ion beam injection

    Energy Technology Data Exchange (ETDEWEB)

    Llacer, J.; Chatterjee, A.; Jackson, H.C.; Lin, J.C.; Zunzunegui, M.V.

    1978-10-01

    The design and performance of an instrument for the imaging of coincidence annihilation gamma rays emitted from the end point of the trajectories of radioactive high-energy heavy ions is described. The positron-emitting heavy ions are the result of nuclear fragmentation of accelerated heavy ions used in cancer therapy or diagnostic medicine. The instrument constructed is capable of locating the ion beam trajectory end point within 1 mm for an injected activity of 200 nanoCi in a measurement time of 1 sec in some favorable conditions. Limited imaging in three dimensions is also demonstrated.

  16. Imaging instrument for positron emitting heavy ion beam injection

    International Nuclear Information System (INIS)

    Llacer, J.; Chatterjee, A.; Jackson, H.C.; Lin, J.C.; Zunzunegui, M.V.

    1978-10-01

    The design and performance of an instrument for the imaging of coincidence annihilation gamma rays emitted from the end point of the trajectories of radioactive high-energy heavy ions is described. The positron-emitting heavy ions are the result of nuclear fragmentation of accelerated heavy ions used in cancer therapy or diagnostic medicine. The instrument constructed is capable of locating the ion beam trajectory end point within 1 mm for an injected activity of 200 nanoCi in a measurement time of 1 sec in some favorable conditions. Limited imaging in three dimensions is also demonstrated

  17. Simulation of the magnetic mirror effect on a beam of positrons

    CERN Document Server

    Boursette, Delphine

    2014-01-01

    I simulated a beam of positrons at the entrance of a 5 Tesla magnet for the Aegis experiment. The goal was to show how many positrons are lost because of the magnetic mirror effect. To do my simulation, I used Comsol to create the magnetic field map and Geant4 to draw the trajectories of the positrons in this field map.

  18. Production of slow positron beam with small diameter using electron linac in Osaka University

    Energy Technology Data Exchange (ETDEWEB)

    Honda, Yoshihide; Sawada, Junichi; Yamada, Masaki; Maekawa, Masaki; Okuda, Shuichi; Yoshida, Yoichi; Isoyama, Goro; Tagawa, Seiichi [Osaka Univ., Ibaraki (Japan). Inst. of Scientific and Industrial Research; Yamamoto, Takayoshi

    1997-03-01

    A slow positron facility using an electron linac was designed and constructed. The specifications were mainly decided by numerical calculations. The slow positrons are transported along magnetic field line. The cross sectional size of slow positron beam is 1-2cm and the maximum conversion rate from electron to positron is about 1.5 x 10{sup -6}. This value is about 1/4 of ideal case in our system. Extraction of slow positron beam from magnetic field region was made and preliminary brightness enhancement experiment was also performed. (author)

  19. Relevance of slow positron beam research to astrophysical studies of positron interactions and annihilation in the interstellar medium

    International Nuclear Information System (INIS)

    Guessoum, N.; Jean, P.; Gillard, W.

    2006-01-01

    The processes undergone by positrons in the interstellar medium (ISM) from the moments of their birth to their annihilation are examined. Both the physics of the positron interactions with gases and solids (dust grains), and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation taking place, are reviewed. An explanation is given as to how all the relevant physical information are taken into account in order to calculate annihilation rates and spectra of the 511 keV emission for the various phases of the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. An attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of slow positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place and ultimately about the birth place and history of positrons in the Galaxy. The important complementarity between work done by the astrophysical and the solid-state positron communities is strongly emphasized and specific experimental work is suggested which could assist the modeling of the interaction and annihilation of positrons in the ISM

  20. Multi-GeV electron-positron beam generation from laser-electron scattering.

    Science.gov (United States)

    Vranic, Marija; Klimo, Ondrej; Korn, Georg; Weber, Stefan

    2018-03-16

    The new generation of laser facilities is expected to deliver short (10 fs-100 fs) laser pulses with 10-100 PW of peak power. This opens an opportunity to study matter at extreme intensities in the laboratory and provides access to new physics. Here we propose to scatter GeV-class electron beams from laser-plasma accelerators with a multi-PW laser at normal incidence. In this configuration, one can both create and accelerate electron-positron pairs. The new particles are generated in the laser focus and gain relativistic momentum in the direction of laser propagation. Short focal length is an advantage, as it allows the particles to be ejected from the focal region with a net energy gain in vacuum. Electron-positron beams obtained in this setup have a low divergence, are quasi-neutral and spatially separated from the initial electron beam. The pairs attain multi-GeV energies which are not limited by the maximum energy of the initial electron beam. We present an analytical model for the expected energy cutoff, supported by 2D and 3D particle-in-cell simulations. The experimental implications, such as the sensitivity to temporal synchronisation and laser duration is assessed to provide guidance for the future experiments.

  1. Automatic sup sup 1 sup sup 8 F positron source supply system for a monoenergetic positron beam

    CERN Document Server

    Saito, F; Itoh, Y; Goto, A; Fujiwara, I; Kurihara, T; Iwata, R; Nagashima, Y; Hyodo, T

    2000-01-01

    A system which supplies an intense sup sup 1 sup sup 8 F (half life 110 min) positron source produced by an AVF cyclotron through sup sup 1 sup sup 8 O(p,n) sup sup 1 sup sup 8 F reaction has been constructed. Produced sup sup 1 sup sup 8 F is transferred to a low background experiment hall through a capillary. It is electro-deposited on a graphite rod and used for a source of a slow positron beam. In the meantime the next batch of target sup sup 1 sup sup 8 O water is loaded and proton irradiation proceeds. This system makes it possible to perform continuous positron beam experiments using the 18 F positron source.

  2. Scattering of thermal photons by a 46 GeV positron beam at LEP

    International Nuclear Information System (INIS)

    Bini, C.; De Zorzi, G.; Diambrini-Palazzi, G.; Di Cosimo, G.; Di Domenico, A.; Gauzzi, P.; Zanello, D.

    1991-01-01

    The scattering of thermal photons present in the vacuum pipe of LEP against the high energy positron beam has been detected. The spectrum of the back-scattered photons is presented for a positron beam energy of 46.1 GeV. Measurements have been performed in the interaction region 1 with the LEP-5 experiment calorimeter. (orig.)

  3. Next generation of electron-positron colliding beam machines

    International Nuclear Information System (INIS)

    Richter, B.

    1979-03-01

    The contribution of electron-positron colliding beam experiments to high-energy physics in the 1970's has been prodigious. From the research done with the two highest-energy e + e - machines of the present generation of these devices, have come such things as the discovery and illumination of the properties of the psi family, charmed particles, a new heavy lepton, non-ambigious evidence for hadronic jets, etc. The rapid pace of new developments in physics from such machines comes about for two reasons. First, the electron-positron annihilation process at present energies is particularly simple and well understood, making the problem of determining the quantum numbers and properties of new particles particularly simple. Second, in electron-positron annihilation all final states are on a relatively equal footing, and small production cross sections are compensated for by a lack of confusing background. For example, the rate of production of charmed particles at the SPEAR storage ring at SLAC and the DORIS storage ring at DESY is 3 or 4 orders of magnitude less than the rate of production at FNAL and the SPS. Yet these particles were first found at the storage rings where the background cross sections are comparable to the signal cross section, and have not yet been observed directly by their hadronic decays at the proton machines where the background cross sections are 4 orders of magnitude larger than the signal cross sections. The machines PEP at SLAC and PETRA at DESY will soon be operating at 35 to 40 GeV cm to explore new regions of energy. Studies of electron-positron annihilation at much higher energies than presently planned have a great deal to teach, not only about particle structure and dynamics, but also about the nature of the weak interaction. Some of the physics which can be done with such machines is discussed with a view toward getting an idea of the minimum required energy for the new generation of colliding beam devices

  4. PREFACE 12th International Workshop on Slow Positron Beam Techniques

    Science.gov (United States)

    Buckman, Stephen; Sullivan, James; White, Ronald

    2011-01-01

    Preface These proceedings arose from the 12th International Workshop on Slow Positron Beam Techniques (SLOPOS12), which was held on Magnetic Island, North Queensland, Australia, between 1-6th August 2010. Meetings in the SLOPOS series are held (roughly) every three years and have now been held on (almost) all continents, indicating the truly international nature of the field. SLOPOS12 marked the second time that the Workshop had been held in the southern hemisphere, and the first time in Australia. SLOPOS12 attracted 122 delegates from 16 countries. Most encouraging was the attendance of 28 student delegates, and that about half of the overall delegates were early career researchers - a good sign for the future of our field. We also enjoyed the company of more than a dozen partners and families of delegates. In a slight departure from previous SLOPOS meetings, the International Advisory Committee approved a broader scope of scientific topics for inclusion in the program for the 2010 Workshop. This broader scope was intended to capture the applications of positrons in atomic, molecular and biomedical areas and was encapsulated in the byeline for SLOPOS-12: The 12th International Workshop on Slow Positron Beam Techniques for Solids, Surfaces, Atoms and Molecules. The scientific and social program for the meeting ran over 6 days with delegates gathering on Sunday August 1st and departing on August 6th. The scientific program included plenary, invited, contributed and student lectures, the latter being the subject of a student prize. In all there were 53 oral presentations during the week. There were also two poster sessions, with 63 posters exhibited, and a prize was awarded for the best poster by a student delegate. The standard of the student presentations, both oral and posters, was outstanding, so much so that the judging panel recommended an additional number of prizes be awarded. Topics that were the focus of invited presentations and contributed papers at

  5. Construction of the spin-polarized slow positron beam with the RI source

    Energy Technology Data Exchange (ETDEWEB)

    Nakajyo, Terunobu; Tashiro, Mutsumi; Kanazawa, Ikuzo [Tokyo Gakugei Univ., Koganei (Japan); Komori, Fumio; Murata, Yoshimasa; Ito, Yasuo

    1997-03-01

    The electrostatic slow-positron beam is constructed by using {sup 22}Na source. We design the electrostatic lens, the system of the detector, and the Wien filter for the experiment`s system of the spin-polarized slow positron beam. The reemitted spin-polarized slow-positron spectroscopy is proposed for studying magnetic thin films and magnetic multilayers. We calculated the depolarized positron fractions in the Fe thin film Fe(10nm)/Cu(substrate) and the multilayers Cu(1nm)/Fe(10nm)/Cu(substrate). (author)

  6. Effect of μe universality violation in muon pair production on colliding electron-positron beams

    International Nuclear Information System (INIS)

    Guliev, N.A.; Dzhafarov, I.G.; Mekhtiev, B.I.

    1981-01-01

    The muonic pair production in colliding electron-positron beams is treated assuming the electron and muon weak interaction constants to be different. General formulae for the differential and total cross sections applicable at arbitrary energies of the colliding beams are obtained taking simultaneously into account arbitrary polarizations of the incident particles and longitudinal polarization of the muon (μ - ). It is shown that study of some polarization characteristics of a given reaction allows to distinguish possible weak interaction μe universality breaking effects. The revealing effects are analysed in the framework of unified gauge SU(2)xU(1) models, of weak and electromagnetic interactions [ru

  7. The Intense Slow Positron Beam Facility at the NC State University PULSTAR Reactor

    International Nuclear Information System (INIS)

    Hawari, Ayman I.; Moxom, Jeremy; Hathaway, Alfred G.; Brown, Benjamin; Gidley, David W.; Vallery, Richard; Xu, Jun

    2009-01-01

    An intense slow positron beam is in its early stages of operation at the 1-MW open-pool PULSTAR research reactor at North Carolina State University. The positron beam line is installed in a beam port that has a 30-cmx30-cm cross sectional view of the core. The positrons are created in a tungsten converter/moderator by pair-production using gamma rays produced in the reactor core and by neutron capture reactions in cadmium cladding surrounding the tungsten. Upon moderation, slow (∼3 eV) positrons that are emitted from the moderator are electrostatically extracted, focused and magnetically guided until they exit the reactor biological shield with 1-keV energy, approximately 3-cm beam diameter and an intensity exceeding 6x10 8 positrons per second. A magnetic beam switch and transport system has been installed and tested that directs the beam into one of two spectrometers. The spectrometers are designed to implement state-of-the-art PALS and DBS techniques to perform positron and positronium annihilation studies of nanophases in matter.

  8. Calibration of an advanced photon source linac beam position monitor used for positron position measurement of a beam containing both positrons and electrons

    International Nuclear Information System (INIS)

    Sereno, Nicholas S.

    1998-01-01

    The Advanced Photon Source (APS) linac beam position monitors can be used to monitor the position of a beam containing both positrons and electrons. To accomplish this task, both the signal at the bunching frequency of 2856 MHz and the signal at 2x2856 MHz are acquired and processed for each stripline. The positron beam position is obtained by forming a linear combination of both 2856 and 5712 MHz signals for each stripline and then performing the standard difference over sum computation. The required linear combination of the 2856 and 5712 MHz signals depends on the electrical calibration of each stripline/cable combination. In this paper, the calibration constants for both 2856 MHz and 5712 MHz signals for each stripline are determined using a pure beam of electrons. The calibration constants are obtained by measuring the 2856 and 5712 MHz stripline signals at various electron beam currents and positions. Finally, the calibration constants measured using electrons are used to determine positron beam position for the mixed beam case

  9. Positron annihilation studies of mesoporous silica films using a slow positron beam

    International Nuclear Information System (INIS)

    He Chunqing; Muramatsu, Makoto; Ohdaira, Toshiyuki; Kinomura, Atsushi; Suzuki, Ryoichi; Ito, Kenji; Kabayashi, Yoshinori

    2006-01-01

    Positron annihilation lifetime spectra were measured for mesoporous silica films, which were synthesized using triblock copolymer (EO 106 PO 70 EO 106 ) as a structure-directing agent. Different positron lifetime spectra for the deposited and calcined films indicated the formation of meso-structure after calcination, which was confirmed by Fourier transform infrared (FTIR) spectra and field emission-scanning electron microscopy (FE-SEM) observation. Open porosity or pore interconnectivity of a silica film might be evaluated by a two-dimensional positron annihilation lifetime spectrum of an uncapped film. Pore sizes and their distributions in the silica films were found to be affected by thermal treatments

  10. Ion-irradiated polymer studied by a slow positron beam

    International Nuclear Information System (INIS)

    Kobayashi, Yoshinori; Kojima, Isao; Hishita, Shunichi; Suzuki, Takenori.

    1995-01-01

    Poly (aryl-ether-ether ketone) (PEEK) films were irradiated with 1MeV and 2MeV 0 + ions and the positron annihilation Doppler broadening was measured as a function of the positron energy. The annihilation lines recorded at relatively low positron energies were found to become broader with increasing the irradiation dose, suggesting that positronium (Ps) formation may be inhibited in the damaged regions. A correlation was observed between the Doppler broadening and spin densities determined by electron spin resonance (ESR). (author)

  11. Design of an efficient pulsing system for a slow-positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Nagayasu; Suzuki, Takenori [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Kanazawa, Ikuzo; Ito, Yasuo

    1996-07-01

    In this paper, a new design of a pulsed slow positron system for PALS measurement is reported. By using this new system, it will be possible to obtain a short-pulsed slow-positron beam with high efficiency ({>=}50%) and a relatively low minimum energy ({approx}200 eV). This system is also easy to construct on the laboratory scale. (J.P.N.)

  12. Dependence of simulated positron emitter yields in ion beam cancer therapy on modeling nuclear fragmentation

    DEFF Research Database (Denmark)

    Lühr, Armin; Priegnitz, Marlen; Fiedler, Fine

    2014-01-01

    In ion beam cancer therapy, range verification in patients using positron emission tomography (PET) requires the comparison of measured with simulated positron emitter yields. We found that (1) changes in modeling nuclear interactions strongly affected the positron emitter yields and that (2) Monte...... Carlo simulations with SHIELD-HIT10A reasonably matched the most abundant PET isotopes 11C and 15O. We observed an ion-energy (i.e., depth) dependence of the agreement between SHIELD-HIT10A and measurement. Improved modeling requires more accurate measurements of cross-section values....

  13. Imaging of water in living plant using neutron beam and positron emitting nuclides

    International Nuclear Information System (INIS)

    Nakanishi, Tomoko M.

    2001-01-01

    Analysis of biological activity in intact cells or tissues is essential to understand many life processes. Techniques for these in vivo measurements have not been well developed. We present here a nondestructive method to image water in living plants using a neutron beam as well as positron emitting nuclides. With high specificity to water, neutron beam technique images water movement in seeds or in roots imbedded in soil, as well as in wood and meristems during development. To know real-time water movement, positron emitting nuclides, 18 F or 15 O was produced by a cyclotron. We present how water uptake activity was shown using these these nuclides. (author)

  14. Development and applications of time-bunched and velocity-selected positron beams

    DEFF Research Database (Denmark)

    Merrison, J.P.; Charlton, M.; Aggerholm, P.

    2003-01-01

    We describe the development of an instrument for the production of low energy positron beams that are bunched in time, and the use of a velocity selection device. The bunching unit was constructed from forty seven separate elements, coupled in series in a capacitor chain to reduce the delay time...

  15. Analysis of defects near the surface and the interface of semiconductors by monoenergetic positron beam

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro

    1989-01-01

    A monoenergetic low-speed positron beam line is constructed and a study is made on defects near the surface and the interface of semiconductors by using the beam line. Sodium-22 is used as beam source. Ion implantation, though being an essential technique for semiconductor integrated circuit production, can introduce lattice defects, affecting the yield and reliability of the resultant semiconductor devices. Some observations are made on the dependence of the Doppler broadening on the depth, and the ΔS-E relationship in P + -ion implanted SiO 2 (43nm)-Si. These observations demonstrate that monoenergetic positron beam is useful to detect hole-type defects resulting from ion implantation over a very wide range of defect density. Another study is made for the detection of defects near an interface. Positrons are expected to drift when left in an electric field with a gradient. Observations made here show that positrons can be concentrated at any desired interface by introducing an electric field intensity gradient in the oxide. This process also serves for accurate measurement of the electronic structure at the interface, and the effect of ion implantation and radiations on the interface. (N.K.)

  16. Acceleration and Focusing of Electrons and Positrons Using a 30 GeV Drive Beam

    International Nuclear Information System (INIS)

    Hogan, Mark J

    2003-01-01

    A series of plasma wakefield acceleration (PWFA) experiments are being conducted with a 30 GeV drive beam from the Stanford Linear Accelerator Center (SLAC). These experiments continue to address the application of meter-scale plasmas to focus and accelerate electrons and positrons in the context of future applications to high-energy accelerators

  17. Interaction of positron beams with thin silver foils and surfaces

    International Nuclear Information System (INIS)

    Rysholt Poulsen, M.

    1994-01-01

    Experimental investigations of positron interactions with solid silver and the necessary platform to analyse the data have been presented. The main objective was to study Ps formation at a Ag(100) surface. The different ingredients of the scenario, including thermalization and diffusion of positrons and emission of Ps, were analysed and quantified in whatever way appropriate. The scattering and possible thermalization were described. The parametrization of Monte-Carlo simulated implantation profiles for semi-infinite materials were presented and the applicability of such profiles to thin foils assessed. The latter was done in conjunction with an analysis of experimental data on thermalization and diffusion in 1900 Aa Ag(100) foils. The necessity for MC simulated rather than parametrized implantation profiles was argued. The velocity of thermally desorbed Ps from a Ag(100) surface at ∼800 K appeared to obey and one-dimensional Maxwell Boltzmann distribution multiplied by a velocity dependent factor. More experimental investigations are needed before firm conclusions can be made on the nature of the emission process. The velocity distribution, though, was found to be near-thermal and indicative of the sample temperature. It has been shown that positrons can be converted into Ps atoms in the transmission geometry of a thin 1900 Aa Ag(100) foil with a high efficiency. Furthermore, 61% of the emitted Ps will have a mean velocity of v z =1.2x10 5 m/sec and 39% will have a maximum kinetic energy of 1.5 eV (v z =5.1x10 5 m/sec) at a foil temperature of 800 K, all velocities that are suitable for producing a 'dense' Ps gas target. (EG) 12 refs

  18. Application of activity pencil beam algorithm using measured distribution data of positron emitter nuclei for therapeutic SOBP proton beam

    International Nuclear Information System (INIS)

    Miyatake, Aya; Nishio, Teiji

    2013-01-01

    Purpose: Recently, much research on imaging the clinical proton-irradiated volume using positron emitter nuclei based on target nuclear fragment reaction has been carried out. The purpose of this study is to develop an activity pencil beam (APB) algorithm for a simulation system for proton-activated positron-emitting imaging in clinical proton therapy using spread-out Bragg peak (SOBP) beams.Methods: The target nuclei of activity distribution calculations are 12 C nuclei, 16 O nuclei, and 40 Ca nuclei, which are the main elements in a human body. Depth activity distributions with SOBP beam irradiations were obtained from the material information of ridge filter (RF) and depth activity distributions of compounds of the three target nuclei measured by BOLPs-RGp (beam ON-LINE PET system mounted on a rotating gantry port) with mono-energetic Bragg peak (MONO) beam irradiations. The calculated data of depth activity distributions with SOBP beam irradiations were sorted in terms of kind of nucleus, energy of proton beam, SOBP width, and thickness of fine degrader (FD), which were verified. The calculated depth activity distributions with SOBP beam irradiations were compared with the measured ones. APB kernels were made from the calculated depth activity distributions with SOBP beam irradiations to construct a simulation system using the APB algorithm for SOBP beams.Results: The depth activity distributions were prepared using the material information of RF and the measured depth activity distributions with MONO beam irradiations for clinical therapy using SOBP beams. With the SOBP width widening, the distal fall-offs of depth activity distributions and the difference from the depth dose distributions were large. The shapes of the calculated depth activity distributions nearly agreed with those of the measured ones upon comparison between the two. The APB kernels of SOBP beams were prepared by making use of the data on depth activity distributions with SOBP beam

  19. Positron annihilation and thermally stimulated current of electron beam irradiated polyetheretherketone

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Shigetaka; Shinyama, Katsuyoshi; Baba, Makoto [Hachinohe Inst. of Tech., Hachinohe, Aomori (Japan); Suzuki, Takenori

    1997-03-01

    Positron lifetime measurements were applied to electron beam irradiated poly(ether-ether-ketone). The lifetime, {tau}{sub 3}, of the ortho-positronium of unirradiated and 5 MGy irradiated specimen became rapidly longer above about 150degC. {tau}{sub 3} of 50 MGy and 100 MGy irradiated specimen was shorter than that of unirradiated one. Thermally stimulated current (TSC) decreased with increasing the dose before voltage application. In the case of voltage application, a TSC peak appeared and the peak value decreased with increased the dose. The correlation between the results of positron annihilation and TSC was investigated. (author)

  20. Defects in heavily phosphorus-doped Si epitaxial films probed by monoenergetic positron beams

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Suzuki, Ryoichi; Ohgaki, Hideaki; Mikado, Tomohisa.

    1994-01-01

    Vacancy-type defects in heavily phosphorus-doped Si epitaxial films were probed by monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured for the epitaxial films grown on the Si substrates by plasma chemical vapor deposition. For the as-deposited film, divacancy-phosphorus complexes were found with high concentration. After 600degC annealing, vacancy clusters were formed near the Si/Si interface, while no drastic change in the depth distribution of the divacancy-phosphorus complexes was observed. By 900degC annealing, the vacancy clusters were annealed out; however, the average number of phosphorus atoms coupled with divacancies increased. The relationship between the vacancy-type defects probed by the positron annihilation technique and the carrier concentration was confirmed. (author)

  1. Defects in heavily phosphorus-doped Si epitaxial films probed by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Suzuki, Ryoichi; Ohgaki, Hideaki; Mikado, Tomohisa

    1994-11-01

    Vacancy-type defects in heavily phosphorus-doped Si epitaxial films were probed by monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured for the epitaxial films grown on the Si substrates by plasma chemical vapor deposition. For the as-deposited film, divacancy-phosphorus complexes were found with high concentration. After 600degC annealing, vacancy clusters were formed near the Si/Si interface, while no drastic change in the depth distribution of the divacancy-phosphorus complexes was observed. By 900degC annealing, the vacancy clusters were annealed out; however, the average number of phosphorus atoms coupled with divacancies increased. The relationship between the vacancy-type defects probed by the positron annihilation technique and the carrier concentration was confirmed. (author).

  2. Simulation of a Positron Source for CEBAF

    International Nuclear Information System (INIS)

    S. Golge; A. Freyberger; C. Hyde-Wright

    2007-01-01

    A positron source for the 6 GeV (or the proposed 12 GeV upgrade) recirculating linacs at Jefferson Lab is presented. The proposed 100nA CW positron source has several unique characteristics; high incident beam power (100kW), 10 MeV incident electron beam energy, CW incident beam and CW production. Positron production with 10 MeV electrons has several advantages; the energy is below neutron threshold so the production target will not become activated during use and the absolute energy spread is bounded by the low incident energy. These advantages are offset by the large angular distribution of the outgoing positrons. Results of simulations of the positron production, capture, acceleration and injection into the recirculating linac are presented. Energy flow and thermal management of the production target present a challenge and are included in the simulations

  3. Status and Perspectives for a Slow Positron Beam Facility at the HH-NIPNE Bucharest

    Science.gov (United States)

    Straticiuc, Mihai; Craciun, Liviu Stefan; Constantinescu, Olimpiu; Ghita, Ionica Alina; Ionescu, Cristina; Racolta, Petru Mihai; Vasilescu, Angela; Braic, Viorel; Zoita, Catalin; Kiss, Adrian; Bojin, Dionezie

    2009-03-01

    The development of a positron annihilation spectroscopy laboratory at the HH-NIPNE Bucharest-to be used for material studies and applications was started in the last 10 years. In the framework of a national research project extended over the last 3 years, was designed a low energy positron accelerator, as a high-vacuum dedicated beam line with two options: a 25 mCi 22NaCl source and in line with the NIPNE-cyclotron or a new intense compact cyclotron. The construction of the beam line was planned as a sequence of modules: source- moderator system; magnetical filter for fast positrons in order to select the positrons energies in the range 0.8-1 keV; a modular system for focusing, transport and acceleration of monoenergetic positrons in the energy range 0.8-50 keV and a CDBS analysis chamber. The moderator proposed-is tungsten as a foil of about 3 μm prepared at the Optoelectronics Institute were put into a thermal treatment vacuum chamber and bombarded with electrons from a 100 W electron gun After the treatment, they were tested for changes of elemental composition of the surface and structure at the Polytechnic University. The structure tests were performed on a DRON 3 M diffractometer, with a Co tube (λKα = 1.7903 A)-the angular regions studied were around 34° (1 0 0) and 69° (2 0 0). In the present time, the trajectories of the positron are going to be simulated with dedicated software (an ion and electron optics simulator). For the coincidence measurements (CDBS) set-up we used a home-made 22NaCl source, by separation without carrier from a metallic Mg target irradiated with 12 MeV protons and separated by columnar cation exchange. A home- made biparametric system for CDBS measurements will be reported, also.

  4. Status and Perspectives for a Slow Positron Beam Facility at the HH—NIPNE Bucharest

    Science.gov (United States)

    Constantin, Florin; Craciun, Liviu Stefan; Constantinescu, Olimpiu; Ghita, Ionica Alina; Ionescu, Cristina; Racolta, Petru Mihai; Straticiuc, Mihai; Vasilescu, Angela; Braic, Viorel; Zoita, Catalin; Kiss, Adrian; Bojin, Dionezie

    2009-03-01

    The development of a positron annihilation spectroscopy laboratory at the HH-NIPNE Bucharest-to be used for material studies and applications was started in the last 10 years. In the framework of a national research project extended over the last 3 years, was designed a low energy positron accelerator, as a high-vacuum dedicated beam line with two options: a 25 mCi 22NaCl source and in line with the NIPNE-cyclotron or a new intense compact cyclotron. The construction of the beam line was planned as a sequence of modules: source- moderator system; magnetical filter for fast positrons in order to select the positrons energies in the range 0.8-1 keV; a modular system for focusing, transport and acceleration of monoenergetic positrons in the energy range 0.8-50 keV and a CDBS analysis chamber. The moderator proposed—is tungsten as a foil of about 3 μm prepared at the Optoelectronics Institute were put into a thermal treatment vacuum chamber and bombarded with electrons from a 100 W electron gun After the treatment, they were tested for changes of elemental composition of the surface and structure at the Polytechnic University. The structure tests were performed on a DRON 3 M diffractometer, with a Co tube (λKα = 1.7903 A)—the angular regions studied were around 34° (1 0 0) and 69° (2 0 0). In the present time, the trajectories of the positron are going to be simulated with dedicated software (an ion and electron optics simulator). For the coincidence measurements (CDBS) set-up we used a home-made 22NaCl source, by separation without carrier from a metallic Mg target irradiated with 12 MeV protons and separated by columnar cation exchange. A home- made biparametric system for CDBS measurements will be reported, also.

  5. Scaling laws for positron production in laser-electron beam collisions

    Science.gov (United States)

    Blackburn, Tom; Ilderton, Anton; Murphy, Christopher; Marklund, Mattias

    2017-10-01

    Showers of gamma rays and positrons are produced when a multi-GeV electron beam collides with a super-intense laser pulse. All-optical realisation of this geometry, where the electron beam is generated by laser-wakefield acceleration, is currently attracting much experimental interest as a probe of radiation reaction and QED effects. These interactions may be modelled theoretically in the framework of strong-field QED or numerically by large-scale PIC simulation. To complement these, we present analytical scaling laws for the electron beam energy loss, gamma ray spectrum, and the positron yield and energy that are valid in the radiation-reaction-dominated regime. These indicate that by employing the collision of a 2 GeV electron beam with a laser pulse of intensity 5 ×1021Wcm-2 , it is possible to produce 10,000 positrons in a single shot at currently available laser facilities. The authors acknowledge support from the Knut and Alice Wallenberg Foundation.

  6. Positron annihilation studies of defects in molecular beam epitaxy grown III-V layers

    International Nuclear Information System (INIS)

    Umlor, M.T.; Keeble, D.J.; Cooke, P.W.

    1994-01-01

    A summary of recent positron annihilation experiments on molecular beam epitaxy (MBE) grown III-V layers is Presented. Variable energy positron beam measurements on Al 0.32 Ga 0.68 As undoped and Si doped have been completed. Positron trapping at a open volume defect in Al 0.32 Ga 0.68 :Si for temperatures from 300 to 25 K in the dark was observed. The positron trap was lost after 1.3 eV illumination at 25K. These results indicate an open volume defect is associated with the local structure of the deep donor state of the DX center. Stability of MBE GaAs to thermal annealing war, investigated over the temperature range of 230 to 700 degrees C, Proximity wafer furnace anneals in flowing argon were used, Samples grown above 450 degrees C were shown to be stable but for sample below this temperature an anneal induced vacancy related defect was produced for anneals between 400 and 500 degrees C. The nature of the defect was shown to be different for material grown at 350 and 230 degrees C. Activation energies of 2.5 eV to 2.3 eV were obtained from isochronal anneal experiments for samples grown at 350 and 230 degrees C, respectively

  7. Intense γ-ray generation for a polarized positron beam in a linear collider

    Directory of Open Access Journals (Sweden)

    Y. Miyahara

    2001-12-01

    Full Text Available γ-ray generation by Compton backscattering in an optical lens series with periodic focal points is considered to produce a polarized positron beam for a linear collider. The lens series is composed of 20 unit cells with a length of 210 mm. Each lens has a hole to pass an electron beam with an energy of 5.8 GeV and the generated γ rays. It is shown by diffraction analysis that laser beam loss in the series is very small, and the beam size is periodically reduced to 26 μm. Electron beam size is reduced to 34 μm in a superconducting solenoid with a field of 15 T. To get a required γ-ray yield of 7×10^{15} γ/s, only one circularly polarized CO_{2} laser source with a power of 24 kW is needed.

  8. Electroweak interactions between intense neutrino beams and dense electron-positron magneto-plasmas

    CERN Document Server

    Tsintsadze, N L; Stenflo, L

    2003-01-01

    The electroweak coupling between intense neutrino beams and strongly degenerate relativistic dense electron-positron magneto-plasmas is considered. The intense neutrino bursts interact with the plasma due to the weak Fermi interaction force, and their dynamics is governed by a kinetic equation. Our objective here is to develop a kinetic equation for a degenerate neutrino gas and to use that equation to derive relativistic magnetohydrodynamic equations. The latter are useful for studying numerous collective processes when intense neutrino beams nonlinearly interact with degenerate, relativistic, dense electron-positron plasmas in strong magnetic fields. If the number densities of the plasma particles are of the order of 10 sup 3 sup 3 cm sup - sup 3 , the pair plasma becomes ultra-relativistic, which strongly affects the potential energy of the weak Fermi interaction. The new system of equations allows several neutrino-driven streaming instabilities involving new types of relativistic Alfven-like waves, The re...

  9. 4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy

    International Nuclear Information System (INIS)

    Parodi, Katia; Saito, Nami; Chaudhri, Naved; Richter, Christian; Durante, Marco; Enghardt, Wolfgang; Rietzel, Eike; Bert, Christoph

    2009-01-01

    Purpose: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable. In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. Methods: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. Results: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged β + -activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered

  10. Beam-on imaging of short-lived positron emitters during proton therapy

    Science.gov (United States)

    Buitenhuis, H. J. T.; Diblen, F.; Brzezinski, K. W.; Brandenburg, S.; Dendooven, P.

    2017-06-01

    In vivo dose delivery verification in proton therapy can be performed by positron emission tomography (PET) of the positron-emitting nuclei produced by the proton beam in the patient. A PET scanner installed in the treatment position of a proton therapy facility that takes data with the beam on will see very short-lived nuclides as well as longer-lived nuclides. The most important short-lived nuclide for proton therapy is 12N (Dendooven et al 2015 Phys. Med. Biol. 60 8923-47), which has a half-life of 11 ms. The results of a proof-of-principle experiment of beam-on PET imaging of short-lived 12N nuclei are presented. The Philips Digital Photon Counting Module TEK PET system was used, which is based on LYSO scintillators mounted on digital SiPM photosensors. A 90 MeV proton beam from the cyclotron at KVI-CART was used to investigate the energy and time spectra of PET coincidences during beam-on. Events coinciding with proton bunches, such as prompt gamma rays, were removed from the data via an anti-coincidence filter with the cyclotron RF. The resulting energy spectrum allowed good identification of the 511 keV PET counts during beam-on. A method was developed to subtract the long-lived background from the 12N image by introducing a beam-off period into the cyclotron beam time structure. We measured 2D images and 1D profiles of the 12N distribution. A range shift of 5 mm was measured as 6  ±  3 mm using the 12N profile. A larger, more efficient, PET system with a higher data throughput capability will allow beam-on 12N PET imaging of single spots in the distal layer of an irradiation with an increased signal-to-background ratio and thus better accuracy. A simulation shows that a large dual panel scanner, which images a single spot directly after it is delivered, can measure a 5 mm range shift with millimeter accuracy: 5.5  ±  1.1 mm for 1  ×  108 protons and 5.2  ±  0.5 mm for 5  ×  108 protons. This makes

  11. Point defects in MnSi and YBCO studied by Doppler Broadening Spectroscopy using a positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Markus

    2015-10-28

    The positron beam NEPOMUC was used in order to investigate MnSi and YBa{sub 2}Cu{sub 3}O{sub 7-δ} (YBCO) single crystals. The Doppler broadening of the annihilation radiation of electron-positron pairs was analyzed. Thus, the concentration of Mn vacancies in MnSi crystals was determined. In thin YBCO films, the Doppler broadening is correlated with the oxygen deficiency δ. Its spatial distribution and its high-temperature behavior were studied using positrons.

  12. Formation of oxygen-related defects enhanced by fluorine in BF{sub 2}{sup +}-implanted Si studied by a monoenergetic positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Moriya, Tsuyoshi; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kawano, Takao; Nagai, Ryo; Umeda, Kazunori

    1995-12-01

    Defects in 25-keV BF{sub 2}{sup +}- or As{sup +}-implanted Si specimens were probed by a monoenergetic positron beam. For the As{sup +}-implanted specimen, the depth profile of defects was obtained from measurements of Doppler broadening profiles as a function of incident positron energy. The major species of the defects was identified as divacancies. For ion-implanted specimens after annealing treatment, oxygen-related defects were found to be formed. For the BF{sub 2}{sup +}-implanted specimen before annealing treatment, such defects were formed in the subsurface region, where oxygen atoms were implanted by recoil from oxide films. This was attributed to enhanced formation of oxygen-related defects by the presence of F atoms. (author)

  13. Undulator-Based Production of Polarized Positrons, A Proposal for the 50-GeV Beam in the FFTB

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, G

    2004-03-25

    The full exploitation of the physics potential of future linear colliders such as the JLC, NLC, and TESLA will require the development of polarized positron beams. In the proposed scheme of Balakin and Mikhailichenko [1] a helical undulator is employed to generate photons of several MeV with circular polarization which are then converted in a relatively thin target to generate longitudinally polarized positrons. This experiment, E-166, proposes to test this scheme to determine whether such a technique can produce polarized positron beams of sufficient quality for use in future linear colliders. The experiment will install a meter-long, short-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) at SLAC. A low-emittance 50-GeV electron beam passing through this undulator will generate circularly polarized photons with energies up to 10 MeV. These polarized photons are then converted to polarized positrons via pair production in thin targets. Titanium and tungsten targets, which are both candidates for use in linear colliders, will be tested. The experiment will measure the flux and polarization of the undulator photons, and the spectrum and polarization of the positrons produced in the conversion target, and compare the measurement results to simulations. Thus the proposed experiment directly tests for the first time the validity of the simulation programs used for the physics of polarized pair production in finite matter, in particular the effects of multiple scattering on polarization. Successful comparison of the experimental results to the simulations will lead to greater confidence in the proposed designs of polarized positrons sources for the next generation of linear colliders. This experiment requests six-weeks of time in the FFTB beam line: three weeks for installation and setup and three weeks of beam for data taking. A 50-GeV beam with about twice the SLC emittance at a repetition rate of 30 Hz is required.

  14. Undulator-Based Production of Polarized Positrons, A Proposal for the 50-GeV Beam in the FFTB

    Energy Technology Data Exchange (ETDEWEB)

    G. Alexander; P. Anthony; V. Bharadwaj; Yu.K. Batygin; T. Behnke; S. Berridge; G.R. Bower; W. Bugg; R. Carr; E. Chudakov; J.E. Clendenin; F.J. Decker; Yu. Efremenko; T. Fieguth; K. Flottmann; M. Fukuda; V. Gharibyan; T. Handler; T. Hirose; R.H. Iverson; Yu. Kamyshkov; H. Kolanoski; T. Lohse; Chang-guo Lu; K.T. McDonald; N. Meyners; R. Michaels; A.A. Mikhailichenko; K. Monig; G. Moortgat-Pick; M. Olson; T. Omori; D. Onoprienko; N. Pavel; R. Pitthan; M. Purohit; L. Rinolfi; K.P. Schuler; J.C. Sheppard; S. Spanier; A. Stahl; Z.M. Szalata; J. Turner; D. Walz; A. Weidemann; J. Weisend

    2003-06-01

    The full exploitation of the physics potential of future linear colliders such as the JLC, NLC, and TESLA will require the development of polarized positron beams. In the proposed scheme of Balakin and Mikhailichenko [1] a helical undulator is employed to generate photons of several MeV with circular polarization which are then converted in a relatively thin target to generate longitudinally polarized positrons. This experiment, E-166, proposes to test this scheme to determine whether such a technique can produce polarized positron beams of sufficient quality for use in future linear colliders. The experiment will install a meter-long, short-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) at SLAC. A low-emittance 50-GeV electron beam passing through this undulator will generate circularly polarized photons with energies up to 10 MeV. These polarized photons are then converted to polarized positrons via pair production in thin targets. Titanium and tungsten targets, which are both candidates for use in linear colliders, will be tested. The experiment will measure the flux and polarization of the undulator photons, and the spectrum and polarization of the positrons produced in the conversion target, and compare the measurement results to simulations. Thus the proposed experiment directly tests for the first time the validity of the simulation programs used for the physics of polarized pair production in finite matter, in particular the effects of multiple scattering on polarization. Successful comparison of the experimental results to the simulations will lead to greater confidence in the proposed designs of polarized positrons sources for the next generation of linear colliders. This experiment requests six-weeks of time in the FFTB beam line: three weeks for installation and setup and three weeks of beam for data taking. A 50-GeV beam with about twice the SLC emittance at a repetition rate of 30 Hz is required.

  15. Experimental Observation of a Current-Driven Instability in a Neutral Electron-Positron Beam

    Science.gov (United States)

    Warwick, J.; Dzelzainis, T.; Dieckmann, M. E.; Schumaker, W.; Doria, D.; Romagnani, L.; Poder, K.; Cole, J. M.; Alejo, A.; Yeung, M.; Krushelnick, K.; Mangles, S. P. D.; Najmudin, Z.; Reville, B.; Samarin, G. M.; Symes, D. D.; Thomas, A. G. R.; Borghesi, M.; Sarri, G.

    2017-11-01

    We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (≥1 T ) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of ɛB≈10-3 is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.

  16. Experimental Observation of a Current-Driven Instability in a Neutral Electron-Positron Beam.

    Science.gov (United States)

    Warwick, J; Dzelzainis, T; Dieckmann, M E; Schumaker, W; Doria, D; Romagnani, L; Poder, K; Cole, J M; Alejo, A; Yeung, M; Krushelnick, K; Mangles, S P D; Najmudin, Z; Reville, B; Samarin, G M; Symes, D D; Thomas, A G R; Borghesi, M; Sarri, G

    2017-11-03

    We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (≥1  T) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of ε_{B}≈10^{-3} is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.

  17. Behavior of obliquely incident vector Bessel beams at planar interfaces

    KAUST Repository

    Salem, Mohamed

    2013-01-01

    We investigate the behavior of full-vector electromagnetic Bessel beams obliquely incident at an interface between two electrically different media. We employ a Fourier transform domain representation of Bessel beams to determine their behavior upon reflection and transmission. This transform, which is geometric in nature, consists of elliptical support curves with complex weighting associated with them. The behavior of the scattered field at an interface is highly complex, owing to its full-vector nature; nevertheless, this behavior has a straightforward representation in the transform domain geometry. The analysis shows that the reflected field forms a different vector Bessel beam, but in general, the transmitted field cannot be represented as a Bessel beam. Nevertheless, using this approach, we demonstrate a method to propagate a Bessel beam in the refractive medium by launching a non- Bessel beam at the interface. Several interesting phenomena related to the behavior of Bessel beams are illustrated, such as polarized reflection at Brewster\\'s angle incidence, and the Goos-Hänchen and Imbert-Federov shifts in the case of total reflection. © 2013 Optical Society of America.

  18. Magnetic focusing of an intense slow positron beam for enhanced depth-resolved analysis of thin films and interfaces

    CERN Document Server

    Falub, C V; Mijnarends, P E; Schut, H; Veen, A V

    2002-01-01

    The intense reactor-based slow positron beam (POSH) at the Delft research reactor has been coupled to a Two-Dimensional Angular Correlation of Annihilation Radiation (2D-ACAR) setup. The design is discussed with a new target chamber for the 2D-ACAR setup based on Monte Carlo simulations of the positron trajectories, beam energy distribution and beam transmission in an increasing magnetic field gradient. Numerical simulations and experiment show that when the slow positron beam with a FWHM of 11.6 mm travels in an increasing axial magnetic field created by a strong NdFeB permanent magnet, the intensity loss is negligible above approx 6 keV and a focusing factor of 5 in diameter is achieved. Monte Carlo simulations and Doppler broadening experiments in the target region show that in this configuration the 2D-ACAR setup can be used to perform depth sensitive studies of defects in thin films with a high resolution. The positron implantation energy can be varied from 0 to 25 keV before entering the non-uniform mag...

  19. Measurement of high-Q2 deep inelastic scattering cross sections with a longitudinally polarised positron beam at HERA

    NARCIS (Netherlands)

    Chekanov, S.; Kooijman, P.

    2006-01-01

    The cross sections for charged and neutral current deep inelastic scattering in e+p collisions with a longitudinally polarised positron beam have been measured using the ZEUS detector at HERA. The results, based on data corresponding to an integrated luminosity of 23.8 pb−1 at , are given for both

  20. Efficient accumulation of antiprotons and positrons, production of slow mono-energetic beams, and their applications

    CERN Document Server

    Yamazaki, Yasunori

    2004-01-01

    Recent progress of ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) project, particularly the antiproton trapping and slow antiproton production, is discussed. An RFQD (Radio Frequency Quadrupole Decelerator) installed in the ASACUSA beam line has an excellent deceleration efficiency of 25% providing 10-130keV antiprotons, which improves the final accumulation efficiency at least one and half orders of magnitude. The decelerated antiprotons are then injected in a large volume multiring trap, stored, and electron-cooled. About 1 million antiprotons are successfully accumulated per one AD shot and 10-500eV antiprotons are extracted as a mono-energetic beam. A UHV compatible positron accumulation is newly developed combining electron plasma and an ion cloud, which yields an accumulation rate as high as 400e **+s/mCi, two and a half orders of magnitude higher than other UHV compatible schemes. A new scheme to synthesize a spin-polarized antihydrogen beam is also discussed, which will play a vit...

  1. Thermal Stress Analyses for a Multislug Beam NLC Positron Target(LCC-0090)

    International Nuclear Information System (INIS)

    Stein, W.

    2003-01-01

    The power deposition of an incident multislug electron beam in a tungsten-rhenium target and the resultant thermal shock stresses in the material have been modeled with a transient, dynamic, structural response finite element code. The Next Linear Collider electron beam is assumed split into two parts, with each part impinging on a 4 radiation lengths thick target. Two targets are required to avoid excessive thermal stresses in the targets. Each of the two beam parts is assumed broken up into four slugs, each two microseconds apart. Energy deposition from each slug occurs over 265 nanoseconds and results in heating of the target and pressure pulses straining the material. The rapid power deposition of the electron beam and the resultant temperature profile in the target generates stress and pressure waves in the material that are considerably larger than those calculated by a static analysis. The 6.22 GeV electron beam has a spot radius size of 1.6 mm and results in a maximum temperature jump of 438 C. Stress pressure pulses are induced in the material from the rapid thermal expansion of the hotter material with peak effective stresses reaching 78 ksi (5.3 x 10 8 Pa) on the back side of the target, which is less than one half of the yield strength of the tungsten/rhenium alloy and below the material fatigue limit

  2. Thermal Stress Analyses for an NLC Positron Target with a 3 mm Spot Radius Beam

    International Nuclear Information System (INIS)

    Stein, W.; Sunwoo, A.; Sheppard, J. C.; Bharadwaj, V.; Schultz, D.

    2002-01-01

    The power deposition of an incident electron beam in a tungsten-rhenium target and the resultant thermal shock stresses in the material have been modeled with a transient, dynamic, structural response finite element code. The Next Linear Collider electron beam is assumed split into three parts, with each part impinging on a 4 radiation lengths thick target. Three targets are required to avoid excessive thermal stresses in the targets. Energy deposition from each beam pulse occurs over 265 nanoseconds and results in heating of the target and pressure pulses straining the material. The rapid power deposition of the electron beam and the resultant temperature profile in the target generates stress and pressure waves in the material that are considerably larger than those calculated by a static analysis. The 6.22 GeV electron beam has a spot radius size of 3 mm and results in a maximum temperature jump of 147 C. Stress pressure pulses are induced in the material from the rapid thermal expansion of the hotter material with peak effective stresses reaching 83 ksi (5.77 x 10 8 Pa) on the back side of the target, which is less than one half of the yield strength of the tungsten/rhenium alloy and below the material fatigue limit

  3. Positron beam and RBS studies of thermally grown oxide films on stainless steel grade 304

    Science.gov (United States)

    Horodek, P.; Siemek, K.; Kobets, A. G.; Kulik, M.; Meshkov, I. N.

    2015-04-01

    The formation of oxide films on surfaces of stainless steel 304 AISI annealed at 800 °C in vacuum, air and in flow N2 atmospheres was studied using variable energy positron beam technique (VEP) and Rutherford backscattering/nuclear reaction (RBS/NR) methods. In frame of these studies, Doppler broadening of annihilation line (DB) measurements were performed. For a sample heated in vacuum the oxide film ca. 8 nm is observed. For specimens oxidized in air and N2 the multi-layered oxide films of about a few hundred nanometers are recognized. The RBS/NR measurements have shown that the sample annealed in vacuum contains a lower quantity of oxygen while for samples heated in the air and N2 non-linear and rather linear time-dependency are observed, respectively. The thicknesses of total oxide films obtained from RBS/NR tests are in good agreement with the VEP results. Time evolution of the oxide growing was studied as well.

  4. Dependance of sputtering yield on incident angle for ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Hironori; Ooba, Hikaru; Masuhara, Kenichi

    1987-07-01

    The relationship between sputtering yeild (S/sub theta/) and the incident angle (theta) of an ion beam to some metals such as Fe, Ni, Zn and SUS304, was studied by Ion Micro Analyzer (IMA). It was confirmed that S/sub theta/ varied as a function of (costheta)/sup -f/. The value of f was differed with each sample, and ranged from 1.0 to 1.5 in this study. As theta increased, the surface roughness of the sputtered samples became greater, and the depth resolution of the depth profile became worse. It is necessary to pay attention to depth resolution, when various data concerning different incident angles are compared.

  5. Positron sources for electron-positron colliders application to the ILC and CLIC

    CERN Multimedia

    CERN. Geneva

    2008-01-01

    The increased demanding qualities for positron sources dedicated to e+e- colliders pushed on investigations oriented on new kinds of e+ sources. The different kinds of positron sources polarized and no polarized are considered. Their main features (intensity, emittance) are described and analysed. Comparison between the different sources is worked out. The characteristics of the positron beam available in the collision point are greatly depending on the capture device and on the positron accelerator. Different kinds of capture systems are considered and their qualities, compared. Intense positron sources which are necessary for the colliders require intense incident beams (electrons or photons). The large number of pairs created in the targets leads to important energy deposition and so, thermal heating, which associated to temperature gradients provoke mechanical stresses often destructive. Moreover, the important Coulomb collisions, can affect the atomic structure in crystal targets and the radiation resist...

  6. Characterization of ion-irradiated ODS Fe–Cr alloys by doppler broadening spectroscopy using a positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Parente, P.; Leguey, T. [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain); Castro, V. de, E-mail: vanessa.decastro@uc3m.es [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain); Gigl, T.; Reiner, M.; Hugenschmidt, C. [FRM II and Physics Department, Technische Universität München, 85747 Garching (Germany); Pareja, R. [Departamento de Física and IAAB, Universidad Carlos III de Madrid, 28911 Leganés (Spain)

    2015-09-15

    The damage profile of oxide dispersion strengthened steels after single-, or simultaneous triple-ion irradiation at different conditions has been characterized using a low energy positron beam in order to provide information on microstructural changes induced by irradiation. Doppler broadening and coincident Doppler broadening measurements of the positron annihilation line have been performed on different Fe–Cr–(W,Ti) alloys reinforced with Y{sub 2}O{sub 3}, to identify the nature and stability of irradiation-induced open-volume defects and their possible association with the oxide nanoparticles. It was found that irradiation induced vacancy clusters are associated with Cr atoms. The results are of highest interest for modeling the damage induced by 14 MeV neutrons in reduced activation Fe–Cr alloys relevant for fusion devices.

  7. Design of an intense positron source for linear colliders

    International Nuclear Information System (INIS)

    Ida, H.; Yamada, K.; Funahashi, Y.

    1994-01-01

    The Japan Linear Collider (JLC) requires an intense positron source of 8x10 11 particles per rf-pulse. A computer simulation reveals the possibility of such an intense positron source using 'conventional' technology. In order to relax the limitation of the incident electron energy density due to thermal stress in the converter target, the incident beam radius is enlarged within the range so as not to reduce the positron capture efficiency. A pre-damping ring and beam transport system to the pre-damping ring, which have a large transverse acceptance, play important roles for a high capture efficiency. A prototype positron source has been designed and installed at downstream of 1.54 GeV S-band linac in Accelerator Test Facility (ATF) in order to carry out experiments to develop the essential technology for JLC. The simulated results will be tested in experiments with the prototype positron source. (author)

  8. A Monte-Carlo simulation of the equilibrium beam polarization in ultra-high energy electron (positron) storage rings

    International Nuclear Information System (INIS)

    Duan, Zhe; Bai, Mei; Barber, Desmond P.; Qin, Qing

    2015-04-01

    With the recently emerging global interest in building a next generation of circular electron-positron colliders to study the properties of the Higgs boson, and other important topics in particle physics at ultra-high beam energies, it is also important to pursue the possibility of implementing polarized beams at this energy scale. It is therefore necessary to set up simulation tools to evaluate the beam polarization at these ultra-high beam energies. In this paper, a Monte-Carlo simulation of the equilibrium beam polarization based on the Polymorphic Tracking Code(PTC) (Schmidt et al., 2002) is described. The simulations are for a model storage ring with parameters similar to those of proposed circular colliders in this energy range, and they are compared with the suggestion (Derbenev et al., 1978) that there are different regimes for the spin dynamics underlying the polarization of a beam in the presence of synchrotron radiation at ultra-high beam energies. In particular, it has been suggested that the so-called ''correlated'' crossing of spin resonances during synchrotron oscillations at current energies, evolves into ''uncorrelated'' crossing of spin resonances at ultra-high energies.

  9. Use of specific features of electron and positron interactions with monocrystals for the control of high-energy particle beam parameters

    International Nuclear Information System (INIS)

    Bochek, G.L.; Vit'ko, V.I.; Grishaev, I.A.; Kovalenko, G.D.; Kulibaba, V.I.; Morokhovskij, V.L.; Shramenko, B.I.

    1977-01-01

    To study possibilities of using the effect of high energy positron and electron interactions with crystals in practice at the 2 GeV Kharkov lineac the effect of a light particle charge sign on the processes of bremsstrahlung, elastic scattering and revealing ''blocking effect'' in elastic scatterina has been investigated experimentally of 1 GeV electron (positron) beam is directed to a silicon crystal of 185 μkm thickness. Dependence of total bremsstrahlung flow on the angle between the beam direction and crystal axis has shown, that positron bremsstrahlung is minimum (positrons are channelling, but electron bremsstrahlung is maximum, when crystallographic axis direction coincides with particle direction. The process of positron annihilation in flight has been investigated in 300 μkm thick silicon monocrystal. Bremsstrahlung intensity for channeling positrons drops 4.4 times, and intensity of annihilation radiation - 1.6 times as compared to the case, when channeling regime is absent. Experimental data point out the possibility of using monocrystals for control of the parameters of high-energy particle control beams

  10. Characteristics of off-waist incident anomalous vortex beams in highly nonlocal media

    Directory of Open Access Journals (Sweden)

    Zhen-Feng Yang

    Full Text Available In this paper, we focus on the effect of the off-waist incident condition on the propagation characteristics of anomalous vortex beams (AVBs in nonlocal media. An expression is derived mathematically in order to describe the propagation dynamics of AVBs in nonlocal media under the off-waist incident condition. Typical propagation characteristics induced by the off-waist incident condition are illustrated numerically. It is found that the propagation characteristics under the off-waist incident condition are much different from those under the on-waist incident condition. Keywords: Off-waist incidence, Anomalous vortex beam, Nonlocal media

  11. Experiments and FLUKA simulations of $^{12}C$ and $^{16}O$ beams for therapy monitoring by means of in-beam Positron Emission Tomography

    CERN Document Server

    Sommerer,; Ferrari, A

    2007-01-01

    Since 1997 at the experimental C-12 ion therapy facility at Gesellschaft fuer Schwerionenforschung (GSI), Darmstadt, Germany, more than 350 patients have been treated. The therapy is monitored with a dedicated positron emission tomograph, fully integrated into the treatment site. The measured beta+-activity arises from inelastic nuclear interactions between the beam particles an the nuclei of the patients tissue. Because the monitoring is done during the irradiation the method is called in-beam PET. The underlying principle of this monitoring is a comparison between the measured activity and a simulated one. The simulations are presently done by the PETSIM code which is dedicated to C-12 beams. In future ion therapy centers like the Heidelberger Ionenstrahl Therapiezentrum (HIT), Heidelberg, Germany, besides C-12 also proton, $^3$He and O-16 beams will be used for treatment and the therapy will be monitored by means of in-beam PET. Because PETSIM is not extendable to other ions in an easy way, a code capable ...

  12. Injectable silver nanosensors: in vivo dosimetry for external beam radiotherapy using positron emission tomography

    DEFF Research Database (Denmark)

    Christensen, Anders Nymark; Rydhög, J. S.; Søndergaard, Rikke Vicki

    2016-01-01

    , which enables post treatment verification of the delivered dose using positron emission tomography imaging. The silver-nanosensor was investigated in a tissue equivalent thorax phantom using clinical settings and workflow for both standard fractionated radiotherapy (2 Gy) and stereotactic radiotherapy...

  13. Influence of laser beam incidence angle on laser lap welding quality of galvanized steels

    Science.gov (United States)

    Mei, Lifang; Yan, Dongbing; Chen, Genyu; Wang, Zhenhui; Chen, Shuixuan

    2017-11-01

    Based on the characteristics of laser welded structural parts of auto bodies, the influence of variation in laser beam incidence angle on the lap welding performance of galvanized auto-body sheets was studied. Lap welding tests were carried out on the galvanized sheets for auto-body application at different laser beam incidence angles by using the optimal welding parameters obtained through orthogonal experiment. The effects of incidence angle variation on seam appearance, cross-sectional shape, joint mechanical properties and microstructure of weldments were analyzed. In addition, the main factors influencing the value of incidence angle were investigated. According to the results, the weld seams had a good appearance as well as a fine, and uniform microstructure when the laser beam incidence angle was smaller than the critical incidence angle, and thus they could withstand great tensile and shear loads. Moreover, all tensile-shear specimens were fractured in the base material zone. When the laser beam incidence angle was larger than the critical incidence angle, defects like shrinkage and collapse tended to emerge, thereby resulting in the deteriorated weldability of specimens. Meanwhile, factors like the type and thickness of sheet, weld width as well as inter-sheet gap all had a certain effect on the value of laser beam incidence angle. When the sheet thickness was small and the weld width was narrow, the laser beam incidence angle could be increased appropriately. At the same time, small changes in the inter-sheet gap could greatly impact the value of incidence angle. When the inter-sheet gap was small, the laser beam incidence angle should not be too large.

  14. The effects of laser beam incident angle and intensity distribution on Fabry-Perot etalon spectrum

    Science.gov (United States)

    Shen, Fahua; Wang, Yingying; Shi, Wenjuan; Chen, Ying; Liu, Mengling; Guo, Wenxin

    2017-11-01

    Fabry-Perot(F-P) etalon has important applications in laser detection, lidar and laser communication systems. In practical applications, the spectrum of the F-P etalon is affected by various factors, such as incident angle, divergence angle, spectral width, intensity distribution of the incident beam, absorption loss, surface defects of the plate and so on. The effects of the incident angle and the beam intensity distribution on F-P etalon spectrum are mainly analyzed. For the first time, taking into account both the beam incident angle and divergence angle, the precise analytical expression of the F-P etalon transmission spectrum is derived. For the Gaussian light intensity distribution, the precise analytical expression of the F-P etalon transmission spectrum is derived. The simulation analysis is carried out and the results are as follows. When the beam divergence angle is not zero, the incident angle increases, on the one hand, the center of the etalon spectrum is moved to the high frequency, and the frequency shift is linear with the square of the incident angle. The slope decreases with the increase of the divergence angle. On the other hand, resulting in peak reduction, spectral line broadening, and with the divergence angle increases, the more obvious the phenomenon. Considering the distribution of Gaussian light intensity, the spectrum of the etalon will be improved with the increase concentration of beam energy. On the one hand, the peak value is increased, the spectral line is narrowed and with the incidence angle increases, the degree of improvement is more obvious. On the one hand, the center of the spectrum moves toward the low frequency, but the larger the incident angle, the smaller the movement amount. The error of frequency discrimination or frequency locking by using the F-P etalon spectrum increases rapidly with the increase of the beam incident angle and beam divergence angle, and the Gaussian light intensity distribution beam can effectively

  15. The beam intensity and positron monitoring system of the Daresbury Electron Synchrotron (NINA)

    International Nuclear Information System (INIS)

    Poole, D.E.; Ring, T.; Peters, D.G.; Allen, J.

    1976-01-01

    The beam sensing system of NINA has been redesigned and rebuilt to provide comprehensive monitoring of beam intensity and position. The reasons for the change are stated, and the requirements and performance specification for the new system are listed. The report falls under the following heads: the sensing head; the head electronics unit; the line receiver unit; performance of installed monitors; display system and computer interface. The performance of the new system is summarized. (U.K.)

  16. Lattice design and beam optics calculations for the new large-scale electron-positron collider FCC-ee

    CERN Document Server

    Haerer, Bastian; Prof. Dr. Schmidt, Ruediger; Dr. Holzer, Bernhard

    Following the recommendations of the European Strategy Group for High Energy Physics, CERN launched the Future Circular Collider Study (FCC) to investigate the feasibility of large-scale circular colliders for future high energy physics research. This thesis presents the considerations taken into account during the design process of the magnetic lattice in the arc sections of the electron-positron version FCC-ee. The machine is foreseen to operate at four different centre-of-mass energies in the range of 90 to 350 GeV. Different beam parameters need to be achieved for every energy, which requires a flexible lattice design in the arc sections. Therefore methods to tune the horizontal beam emittance without re-positioning machine components are implemented. In combination with damping and excitation wigglers a precise adjustment of the emittance can be achieved. A very first estimation of the vertical emittance arising from lattice imperfections is performed. Special emphasis is put on the optimisation of the ...

  17. Polarization Study for NLC Positron Source Using EGS4

    Energy Technology Data Exchange (ETDEWEB)

    Liu, James C

    2000-09-20

    SLAC is exploring a polarized positron source to study new physics for the NLC project. The positron source envisioned in this paper consists of a polarized electron source, a 50-MeV electron accelerator, a thin target less-than-or-equal-to 0.2 radiation length for positron production, and a capture system for high-energy, small angular divergence positrons. The EGS4 code was used to study the yield, energy spectra, emission-angle distribution, and the mean polarization of the positrons emanating from W-Re and Ti targets hit by longitudinally polarized electron and photon beams. To account for polarization within the EGS4 code a method devised by Flottmann was used, which takes into account polarization transfer for pair production, bremsstrahlung, and Compton interactions. A mean polarization of 0.85 for positrons with energies greater than 25 MeV was obtained. Most of the high-energy positrons were emitted within a forward angle of 20 degrees. The yield of positrons above 25 MeV per incident photon was 0.034, which was about 70 times higher than that obtained with an electron beam.

  18. Measurement of positron reemission from thin single-crystal W(100) films

    International Nuclear Information System (INIS)

    Chen, D.M.; Lynn, K.G.; Pareja, R.; Nielsen, B.

    1985-01-01

    Epitaxial thin single-crystal (100) tungsten films 1000, 2500, and 5000 A thick have been fabricated by high-vacuum electron-beam evaporation. These films were subsequently used as thin-film moderators for the study of the positron-transmission-reemission process with a variable-energy (0--80 keV) monoenergetic positron beam in an ultrahigh-vacuum system. The films were shown to be routinely cleanable by heating first in oxygen (10 -6 Torr) and then in vacuum (10 -9 Torr). Transmission and back reemission of slow positrons from these surfaces was observed. The positron work function, phi/sub +/ has been determined to be approx. =3.0 eV ( +- 0.3 eV). The transmission slow positrons were emitted in a narrow cone with a full width at half maximum of approx. =30 0 consistent with the angular distribution of back-reemission positrons. The reemitted yields as a function of incident positron energy were found to be very different between forward reemission and back reemission. The maximum forward-reemission yields were 18% for 1000-A-thick W film and 12% for 2500-A-thick W film at 5 and 10 keV optimum incident positron energies, respectively. These results show that one can use thin single-crystal tungsten films as positron moderators or remoderators

  19. High current pulsed positron microprobe

    International Nuclear Information System (INIS)

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-01-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10 10 e + s -l beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions

  20. Study of an instability of the PEP-II positron beam (Ohmi effect and multipactoring)

    International Nuclear Information System (INIS)

    Heifets, S.A.

    1995-11-01

    The paper is organized in the following way. First, Ohmi effect induced by direct flow of primary photoelectrons is studied for the PEP-II parameters. The production rate and kinematics take into account the antechamber of the LER. We discuss the effect of the secondary emission of electrons in the AL chamber, where the yield is larger than one. Resonance multipactoring is considered, and then the average density of the secondary electrons is estimated taking into account the space-charge effect and the interaction with the beam. We show that in the extreme case there is a self-consistent regime similar to the regime of the space-charge dominated cathode. Finally, the rate of ion production by accumulated electrons and the possibility of the ion induced pressure instability is discussed

  1. Recovering about 5 km of LHC Beam Vacuum System after Sector 3-4 Incident

    CERN Document Server

    Baglin, Vincent; Jenninger, Berthold; Jimenez, Jose; Mahner, Edgar; Schneider, Gerhard; Sinturel, Alexandre; Vidal, Alexis

    2010-01-01

    During the sec­tor 3-4 incident, the two apertures of the 3 km long cryogenic vacuum sectors of the CERN Large Hadron Collider (LHC) were brutally vented to helium. A systematic visual inspection of the beam pipe revealed the presence of soot, metallic debris and super insulation debris. After four month of cleaning, the beam vacuum system was recovered. This paper describes the tools and methodologies developed during this period, the achieved performances and discusses possible upgrades

  2. Positron emission tomography for the dose monitoring of intra-fractionally moving targets in ion beam therapy

    International Nuclear Information System (INIS)

    Stuetzer, Kristin

    2014-01-01

    Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumor conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumor volume to reach higher tumor control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumor entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumor sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion-compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two β + -activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the

  3. Positron emission tomography for the dose monitoring of intra-fractionally moving targets in ion beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stuetzer, Kristin

    2014-07-01

    Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumor conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumor volume to reach higher tumor control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumor entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumor sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion-compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two β{sup +}-activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the

  4. Positron annihilation near fractal surfaces

    International Nuclear Information System (INIS)

    Lung, C.W.; Deng, K.M.; Xiong, L.Y.

    1991-07-01

    A model for positron annihilation in the sub-surface region near a fractal surface is proposed. It is found that the power law relationship between the mean positron implantation depth and incident positron energy can be used to measure the fractal dimension of the fractal surface in materials. (author). 10 refs, 2 figs

  5. Study on low-energy positron polarimetry

    Indian Academy of Sciences (India)

    A polarised positron source has been proposed for the design of the international linear collider (ILC). In order to optimise the positron beam, a measurement of its degree of polarisation close to the positron creation point is desired. In this contribution, methods for determining the positron polarisation at low energies are ...

  6. Large-angle production of charged pions with incident pion beams on nuclear targets

    CERN Document Server

    Apollonio, M.; Bagulya, A.; Barr, G.; Blondel, A.; Bobisut, F.; Bogomilov, M.; Bonesini, M.; Booth, C.; Borghi, S.; Bunyatov, S.; Burguet-Castell, J.; Catanesi, M.G.; Cervera-Villanueva, A.; Chimenti, P.; Coney, L.; Di Capua, E.; Dore, U.; Dumarchez, J.; Edgecock, R.; Ellis, M.; Ferri, F.; Gastaldi, U.; Giani, S.; Giannini, G.; Gibin, D.; Gilardoni, S.; Gorbunov, P.; Gossling, C.; Gomez-Cadenas, J.J.; Grant, A.; Graulich, J.S.; Gregoire, G.; Grichine, V.; Grossheim, A.; Guglielmi, A.; Howlett, L.; Ivanchenko, A.; Ivanchenko, V.; Kayis-Topaksu, A.; Kirsanov, M.; Kolev, D.; Krasnoperov, A.; Martin-Albo, J.; Meurer, C.; Mezzetto, M.; Mills, G.B.; Morone, M.C.; Novella, P.; Orestano, D.; Palladino, V.; Panman, J.; Papadopoulos, I.; Pastore, F.; Piperov, S.; Polukhina, N.; Popov, B.; Prior, G.; Radicioni, E.; Schmitz, D.; Schroeter, R.; Skoro, G.; Sorel, M.; Tcherniaev, E.; Temnikov, P.; Tereschenko, V.; Tonazzo, A.; Tortora, L.; Tsenov, R.; Tsukerman, I.; Vidal-Sitjes, G.; Wiebusch, C.; Zucchelli, P.

    2009-01-01

    Measurements of the double-differential pi+/- production cross-section in the range of momentum 100 MeV/c <= p <= 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad using pi+/- beams incident on beryllium, aluminium, carbon, copper, tin, tantalum and lead targets are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN PS. The secondary pions were produced by beams in a momentum range from 3 GeV/c to 12.9 GeV/c hitting a solid target with a thickness of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using a small-radius cylindrical time projection chamber (TPC) placed inside a solenoidal magnet. Incident particles were identified by an elaborate system of beam detectors. Results are obtained for the double-differential cross-sections d2sigma/dpdtheta at six incident beam momenta. Data at 3 GeV/c, 5 GeV/c, 8 GeV/c, and 12 GeV/c are available for all targets while additional data at 8.9 GeV/...

  7. Microstructural study of He-implanted Fe-Cr alloys with the use of conventional lifetime technique and pulsed low energy positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Krsjak, Vladimir [Institute for Energy, Joint Research Centre of the European Commission, Petten (Netherlands); Slugen, Vladimir; Petriska, Martin; Sojak, Stanislav [Slovak University of Technology, FEI, Bratislava (Slovakia); Egger, Werner [Institut fuer Angewandte Physik und Messtechnik, Universitaet der Bundeswehr Muenchen, Neubiberg (Germany)

    2009-11-15

    Experimental simulation of the radiation damage using He+ implantation has been performed in research of Fe-Cr model alloys. Different chromium content in the studied materials enables investigations of the effect of this element on the microstructure of radiation treated materials. The damaged region was investigated with the positron lifetime techniques with focus on the size and distribution of the defects. Our measurements show that not only pulsed low energy positron beam spectroscopy (PLEPS) but also conventional lifetime spectroscopy can study the behaviour of vacancy type defects induced by implantation of charged particles. Our results show that initial microstructure of low Cr alloys with significant presence of vacancy type defects is less resistant to creation of defect agglomeration in comparison with higher Cr alloys. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Study on laser welding of austenitic stainless steel by varying incident angle of pulsed laser beam

    Science.gov (United States)

    Kumar, Nikhil; Mukherjee, Manidipto; Bandyopadhyay, Asish

    2017-09-01

    In the present work, AISI 304 stainless steel sheets are laser welded in butt joint configuration using a robotic control 600 W pulsed Nd:YAG laser system. The objective of the work is of twofold. Firstly, the study aims to find out the effect of incident angle on the weld pool geometry, microstructure and tensile property of the welded joints. Secondly, a set of experiments are conducted, according to response surface design, to investigate the effects of process parameters, namely, incident angle of laser beam, laser power and welding speed, on ultimate tensile strength by developing a second order polynomial equation. Study with three different incident angle of laser beam 89.7 deg, 85.5 deg and 83 deg has been presented in this work. It is observed that the weld pool geometry has been significantly altered with the deviation in incident angle. The weld pool shape at the top surface has been altered from semispherical or nearly spherical shape to tear drop shape with decrease in incident angle. Simultaneously, planer, fine columnar dendritic and coarse columnar dendritic structures have been observed at 89.7 deg, 85.5 deg and 83 deg incident angle respectively. Weld metals with 85.5 deg incident angle has higher fraction of carbide and δ-ferrite precipitation in the austenitic matrix compared to other weld conditions. Hence, weld metal of 85.5 deg incident angle achieved higher micro-hardness of ∼280 HV and tensile strength of 579.26 MPa followed by 89.7 deg and 83 deg incident angle welds. Furthermore, the predicted maximum value of ultimate tensile strength of 580.50 MPa has been achieved for 85.95 deg incident angle using the developed equation where other two optimum parameter settings have been obtained as laser power of 455.52 W and welding speed of 4.95 mm/s. This observation has been satisfactorily validated by three confirmatory tests.

  9. Feasibility studies of a polarized positron source based on the Bremsstrahlung of polarized electrons

    International Nuclear Information System (INIS)

    Dumas, J.

    2011-09-01

    The nuclear and high-energy physics communities have shown a growing interest in the availability of high current, highly-polarized positron beams. A sufficiently energetic polarized photon or lepton incident on a target may generate, via Bremsstrahlung and pair creation within a solid target foil, electron-positron pairs that should carry some fraction of the initial polarization. Recent advances in high current (> 1 mA) spin polarized electron sources at Jefferson Lab offer the perspective of creating polarized positrons from a low energy electron beam. This thesis discusses polarization transfer from electrons to positrons in the perspective of the design optimization of a polarized positron source. The PEPPo experiment, aiming at a measurement of the positron polarization from a low energy (< 10 MeV) highly spin polarized electron beam is discussed. A successful demonstration of this technique would provide an alternative scheme for the production of low energy polarized positrons and useful information for the optimization of the design of polarized positron sources in the sub-GeV energy range. (author)

  10. Low-energy positron interactions with atoms and molecules

    International Nuclear Information System (INIS)

    Surko, C M; Gribakin, G F; Buckman, S J

    2005-01-01

    This paper is a review of low-energy positron interactions with atoms and molecules. Processes of interest include elastic scattering, electronic and vibrational excitation, ionization, positronium formation and annihilation. An overview is presented of the currently available theoretical and experimental techniques to study these phenomena, including the use of trap-based positron beam sources to study collision processes with improved energy resolution. State-resolved measurements of electronic and vibrational excitation cross sections and measurement of annihilation rates in atoms and molecules as a function of incident positron energy are discussed. Where data are available, comparisons are made with analogous electron scattering cross sections. Resonance phenomena, common in electron scattering, appear to be less common in positron scattering. Possible exceptions include the sharp onsets of positron-impact electronic and vibrational excitation of selected molecules. Recent energy-resolved studies of positron annihilation in hydrocarbons containing more than a few carbon atoms provide direct evidence that vibrational Feshbach resonances underpin the anomalously large annihilation rates observed for many polyatomic species. We discuss open questions regarding this process in larger molecules, as well as positron annihilation in smaller molecules where the theoretical picture is less clear. (topical review)

  11. Beam test measurements on GaAs pixel detectors at various angles of incidence

    Energy Technology Data Exchange (ETDEWEB)

    Braunschweig, W.; Breibach, J.; Graessel, D.; Koenig, St.; Kubicki, Th.; Luebelsmeyer, K.; Rente, C.; Roeper, Ch.; Siedling, R.; Syben, O.; Tenbusch, F.; Toporowski, M.; Xiao, W.J

    1999-08-01

    A GaAs pixel detector constructed in Aachen has been tested in a 4 GeV electron beam at DESY. The experimental setup allowed tilting the detector with respect to the beam line with angles of incidence from 0 deg. to 45 deg. . The sensor-array consisted of 8 x 16 pixels with a size of 125 x 125{mu}m{sup 2} each. The detector was made of a 250{mu}m thick Freiberger SI-GaAs wafer. An improved contact was formed on the backside, allowing safe operation of the detector in the soft breakdown regime. A double metal technique allowed bonding the single pixels linearly to the readout-chip. Using the the fast PreMux128 preamplifier multiplexer chip ({tau}{sub p} = 40ns) a signal to noise ratio of 29 was obtained for a beam angle of incidence of 0 deg. increasing up to 38 for 45 deg. The spatial resolution obtained with an angle of incidence of 45 deg. was (9.0 {+-} 6.0){mu}m while the resolution of the untilted detector is equal to the digital one (36.1{mu}m). For these testbeam-measurements the detector was connected to the electronics via wire-bonds. For future experiments bump-bonding connections are required. The results of a process for the formation of bump-bond connections on GaAs pixeldetectors are shown.

  12. Measurement of high-Q{sup 2} charged current deep inelastic scattering cross sections with a longitudinally polarised positron beam at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Abramowicz, H. [Tel Aviv Univ. (Israel). Faculty of Exact Sciences, School of Physics; Max-Planck-Inst., Munich (Germany); Abt, I. [Max-Planck-Inst. fuer Physik, Muenchen (Germany); Adamczyk, L. [AGH-Univ. of Science and Technology, Cracow (PL). Faculty of Physics and Applied Computer Science] (and others)

    2010-08-15

    Measurements of the cross sections for charged current deep inelastic scattering in e{sup +}p collisions with a longitudinally polarised positron beam are presented. The measurements are based on a data sample with an integrated luminosity of 132 pb{sup -1} collected with the ZEUS detector at HERA at a centre-of-mass energy of 318 GeV. The total cross section is presented at positive and negative values of the longitudinal polarisation of the positron beams. The single-differential cross sections d{sigma}/dQ{sup 2}, d{sigma}/dx and d{sigma}/dy are presented for Q{sup 2}>200 GeV{sup 2}. The reduced cross-section {sigma} is presented in the kinematic range 200

  13. Measurement of high-Q{sup 2} neutral current deep inelastic e{sup +}p scattering cross sections with a longitudinally polarised positron beam at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Abramowicz, H. [Tel Aviv Univ. (Israel). School of Physics; Max Planck Institute for Physics, Munich (Germany); Abt, I. [Max Planck Institute for Physics, Munich (Germany); Adamczyk, L. [AGH-Univ. of Science and Technology, Krakow (Poland). Faculty of Physics and Applied Computer Science] [and others; Collaboration: ZEUS Collaboration

    2012-08-15

    Measurements of neutral current cross sections for deep inelastic scattering in e{sup +}p collisions at HERA with a longitudinally polarised positron beam are presented. The single-differential cross-sections d{sigma}/dQ{sup 2}, d{sigma}/dx and d{sigma}/dy and the reduced cross-section {sigma} were measured in the kinematic region Q{sup 2}>185 GeV{sup 2} and y<0.9, where Q{sup 2} is the four-momentum transfer squared, x the Bjorken scaling variable, and y the inelasticity of the interaction. The measurements were performed separately for positively and negatively polarised positron beams. The measurements are based on an integrated luminosity of 135.5 pb{sup -1} collected with the ZEUS detector in 2006 and 2007 at a centre-of-mass energy of 318 GeV. The structure functions F{sub 3} and F{sup {gamma}Z}{sub 3} were determined by combining the e{sup +}p results presented in this paper with previously published e{sup -}p neutral current results. The asymmetry parameter A{sup +} is used to demonstrate the parity violation predicted in electroweak interactions. The measurements are well described by the predictions of the Standard Model.

  14. Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams.

    Science.gov (United States)

    Kuess, Peter; Georg, Dietmar; Palmans, Hugo; Lechner, Wolfgang

    2016-08-01

    For commercially available linear accelerators (Linacs), the electron energies of flattening filter free (FFF) and flattened (FF) beams are either identical or the electron energy of the FFF beam is increased to match the percentage depth dose curve (PDD) of the FF beam (in reference geometry). This study focuses on the primary dose components of FFF beams for both kinds of settings, studied on the same Linac. The measurements were conducted on a VersaHD Linac (Elekta, Crawley, UK) for both FF and FFF beams with nominal energies of 6 and 10 MV. In the clinical setting of the VersaHD, the energy of FFFM (Matched) beams is set to match the PDDs of the FF beams. In contrast the incident electron beam of the FFFU beam was set to the same energy as for the FF beam. Half value layers (HVLs) and a dual parameter beam quality specifier (DPBQS) were determined. For the 6 MV FFFM beam, HVL and DPBQS values were very similar compared to those of the 6 MV FF beam, while for the 10 MV FFFM and FF beams, only %dd(10)x and HVL values were comparable (differences below 1.5%). This shows that matching the PDD at one depth does not guarantee other beam quality dependent parameters to be matched. For FFFU beams, all investigated beam quality specifiers were significantly different compared to those for FF beams of the same nominal accelerator potential. The DPBQS of the 6 MV FF and FFFM beams was equal within the measurement uncertainty and was comparable to published data of a machine with similar TPR20,10 and %dd(10)x. In contrast to that, the DPBQS's two parameters of the 10 MV FFFM beam were substantially higher compared to those for the 10 MV FF beam. PDD-matched FF and FFF beams of both nominal accelerator potentials were observed to have similar HVL values, indicating similarity of their primary dose components. Using the DPBQS revealed that the mean attenuation coefficient was found to be the same within the uncertainty of 0.8% for 6 MV FF and 6 MV FFFM beams, while for 10 MV

  15. Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams

    International Nuclear Information System (INIS)

    Kuess, Peter; Georg, Dietmar; Lechner, Wolfgang; Palmans, Hugo

    2016-01-01

    Purpose: For commercially available linear accelerators (Linacs), the electron energies of flattening filter free (FFF) and flattened (FF) beams are either identical or the electron energy of the FFF beam is increased to match the percentage depth dose curve (PDD) of the FF beam (in reference geometry). This study focuses on the primary dose components of FFF beams for both kinds of settings, studied on the same Linac. Methods: The measurements were conducted on a VersaHD Linac (Elekta, Crawley, UK) for both FF and FFF beams with nominal energies of 6 and 10 MV. In the clinical setting of the VersaHD, the energy of FFF M (Matched) beams is set to match the PDDs of the FF beams. In contrast the incident electron beam of the FFF U beam was set to the same energy as for the FF beam. Half value layers (HVLs) and a dual parameter beam quality specifier (DPBQS) were determined. Results: For the 6 MV FFF M beam, HVL and DPBQS values were very similar compared to those of the 6 MV FF beam, while for the 10 MV FFF M and FF beams, only %dd(10) x and HVL values were comparable (differences below 1.5%). This shows that matching the PDD at one depth does not guarantee other beam quality dependent parameters to be matched. For FFF U beams, all investigated beam quality specifiers were significantly different compared to those for FF beams of the same nominal accelerator potential. The DPBQS of the 6 MV FF and FFF M beams was equal within the measurement uncertainty and was comparable to published data of a machine with similar TPR 20,10 and %dd(10) x . In contrast to that, the DPBQS’s two parameters of the 10 MV FFF M beam were substantially higher compared to those for the 10 MV FF beam. Conclusions: PDD-matched FF and FFF beams of both nominal accelerator potentials were observed to have similar HVL values, indicating similarity of their primary dose components. Using the DPBQS revealed that the mean attenuation coefficient was found to be the same within the uncertainty of

  16. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.H.; Stoeffl, W.

    1998-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world's highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectra

  17. Construction report of the PF slow-positron source. 1

    International Nuclear Information System (INIS)

    Enomoto, Atsushi; Kurihara, Toshikazu; Kobayashi, Hitoshi

    1993-12-01

    The slow positron source utilizing the electron beam of the 2.5 GeV electron beam accelerator which is the synchrotron radiation injector is being constructed. The outline of the project and the present state of construction are reported. As of November, 1993, by injecting the electron beam of about 10 W to the targets for producing positrons, the slow positrons of 4 x 10 4 e + /s has been obtained in the laboratory. Finally, with the electron beam of 30 kW, it is aimed at to obtain the slow positron beam of 2 x 10 9 e + /s. In the slow positron source, the electron beam from the 2.5 GeV linear accelerator is used as the primary beam. This beam is led to the target with electromagnets. Radiation shields were strengthened, and the electrostatic lens system was attached to efficiently extract and send out slow positrons. The conveying system for slow positrons is explained. Primary electron beam, target and moderator for producing slow positrons, the change to continuous current of pulsed slow positron beam and the heightening of luminance of slow positron beam, and the experiment on the utilization of slow positron beam, and the control system for positron conveyance path are reported. (K.I.)

  18. Optimum solution of dual-ring double-scattering system for an incident beam with given phase space for proton beam spreading

    CERN Document Server

    Takada, Y

    2002-01-01

    A systematic method is given for deriving optimum scatterer parameters for the dual-ring double-scattering system for the incident proton beam with the given phase space parameters. This is accomplished by relating it to the known optimum solution for zero-emittance beam. Limitations on the phase space parameters of the beam incident on the first scatterer have been clarified to obtain such valid solutions. It is shown that the dual-ring double-scattering method can be applied to an incident beam with emittance as large as 100-200 pi mm mrad. The effect of the change of phase space parameters on the lateral distribution has been investigated. It was found that the larger the emittance of the beam, the more sensitive the fluence distribution is to the change of phase space parameters. The effect of the different emittances of the incident beam in x-theta, y-phi spaces is discussed. It is shown that lateral distribution is sensitive to the misalignment of the beam.

  19. Argon Beam Coagulator in Breast Surgery: Effect on the Incidence of Breast Seroma.

    Science.gov (United States)

    Lefemine, Valentina; Cornish, Julie A; Abou-Samra, Walid

    2011-12-01

    Although Argon Beam Coagulators (ABCs) are widely used in urological and gynecological procedures, there have been only two studies published so far on their use and benefits in breast surgery. This study compares the incidence of breast seroma following mastectomy upon the use of ABC versus standard monopolar diathermy. This is a retrospective cohort study, with data collected from January 2006 to August 2008 for all patients who underwent a simple mastectomy and axillary surgery. Outcomes included incidence of seroma, amount of drainage on day of discharge, and timing of seroma formation. Fifty-six patients were studied, with 30 undergoing simple mastectomy using ABC diathermy and 25 using simple diathermy. The incidence of postoperative breast seroma development was 30% (n = 9) in the former group and 36% (n = 9) in the latter. In the ABC group, a high postoperative drainage at discharge was predictive of developing a seroma; this was not observed in the monopolar group. The search for methods to reduce the incidence of seroma in breast surgery is ongoing worldwide. Despite a previous report, this study failed to show any significant difference between ABC and monopolar diathermy in the incidence of breast seroma formation following simple mastectomy and axillary surgery. ABC diathermy is more costly, and its use needs to be carefully considered in an era of a stretched National Health Service financial budget.

  20. Design analysis and performance evaluation of a two-dimensional camera for accelerated positron-emitter beam injection by computer simulation

    International Nuclear Information System (INIS)

    Llacer, J.; Chatterjee, A.; Batho, E.K.; Poskanzer, J.A.

    1982-05-01

    The characteristics and design of a high-accuracy and high-sensitivity 2-dimensional camera for the measurement of the end-point of the trajectory of accelerated heavy ion beams of positron emitter isotopes are described. Computer simulation methods have been used in order to insure that the design would meet the demanding criteria of ability to obtain the location of the centroid of a point source in the X-Y plane with errors smaller than 1 mm, with an activity of 100 nanoCi, in a counting time of 5 sec or less. A computer program which can be developed into a general purpose analysis tool for a large number of positron emitter camera configurations is described in its essential parts. The validation of basic simulation results with simple measurements is reported, and the use of the program to generate simulated images which include important second order effects due to detector material, geometry, septa, etc. is demonstrated. Comparison between simulated images and initial results with the completed instrument shows that the desired specifications have been met

  1. Vacancy-type defects in InxGa1−xN grown on GaN templates probed using monoenergetic positron beams

    International Nuclear Information System (INIS)

    Uedono, Akira; Watanabe, Tomohito; Kimura, Shogo; Zhang, Yang; Lozac'h, Mickael; Sang, Liwen; Sumiya, Masatomo; Ishibashi, Shoji; Oshima, Nagayasu; Suzuki, Ryoichi

    2013-01-01

    Native defects in In x Ga 1−x N layers grown by metalorganic chemical vapor deposition were studied using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and lifetime spectra of positrons for a 200-nm-thick In 0.13 Ga 0.87 N layer showed that vacancy-type defects were introduced by InN alloying, and the major species of such defects was identified as complexes between a cation vacancy and nitrogen vacancies. The presence of the defects correlated with lattice relaxation of the In 0.13 Ga 0.87 N layer and the increase in photon emissions from donor-acceptor-pair recombination. The species of native defects in In 0.06 Ga 0.94 N layers was the same but its concentration was decreased by decreasing the InN composition. With the layer thickness increased from 120 nm to 360 nm, a defect-rich region was introduced in the subsurface region (<160 nm), which can be associated with layer growth with the relaxation of compressive stress

  2. Frozen-in vacancies in PVD-Cu films with improved high-pressure reflowability studied using a slow positron beam

    International Nuclear Information System (INIS)

    Yabuuchi, A; Kubo, D; Mizuno, M; Araki, H; Onishi, T; Shirai, Y

    2009-01-01

    Recently, a new process has been proposed for fabricating a LSI interconnection; filling trenches and via holes with Cu using high-pressure annealing treatment. It is already known that a Cu film produced by physical vapor deposition (PVD) has a lower reflowability compared to a Cu film produced by electrochemical deposition (ECD). Additionally, it has also been recognized that the addition of Sb to the PVD-Cu film improves the reflowability. However, the factors responsible for the reflowability of Cu films have not yet been studied. In this work, we evaluated a PVD pure-Cu film and a PVD Cu-0.5at%Sb film by using a slow positron beam. Addition of Sb led to the introduction of lattice defects in the as-deposited film. These defects that were observed in the PVD-CuSb dilute alloy film were identified as frozen-in vacancies that were produced during deposition.

  3. Effects of recoil-implanted oxygen on depth profiles of defects and annealing processes in P{sup +}-implanted Si studied using monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Moriya, Tsuyoshi; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kitano, Tomohisa; Watanabe, Masahito; Kawano, Takao; Suzuki, Ryoichi; Ohdaira, Toshiyuki; Mikado, Tomohisa

    1996-04-01

    Effects of oxygen atoms recoiled from SiO{sub 2} films on depth profiles of defects and annealing processes in P{sup +}-implanted Si were studied using monoenergetic positron beams. For an epitaxial Si specimen, the depth profile of defects was found to be shifted toward the surface by recoil implantation of oxygen atoms. This was attributed to the formation of vacancy-oxygen complexes and a resultant decrease in the diffusion length of vacancy-type defects. The recoiled oxygen atoms stabilized amorphous regions introduced by P{sup +}-implantation, and the annealing of these regions was observed after rapid thermal annealing (RTA) at 700degC. For a Czochralski-grown Si specimen fabricated by through-oxide implantation, the recoiled oxygen atoms introduced interstitial-type defects upon RTA below the SiO{sub 2}/Si interface, and such defects were dissociated by annealing at 1000degC. (author)

  4. A new experiment to investigate the origin of optical activity using a low energy positron beam of controlled helicity. [molecular biology

    Science.gov (United States)

    Gidley, D. W.; Rich, A.; Van House, J. C.; Zitzewitz, P. W.

    1981-01-01

    Previous experiments undertaken in search of a correlation between the origin of optical activity in biological molecules and the helicity of beta particles emitted in nuclear beta decay have not provided any useful results. A description is presented of an experiment in which a low energy polarized positron beam of controlled helicity interacts with an optically active material to form positronium in vacuum. Advantages of the current study compared to the previous experiments are mainly related to a much greater sensitivity. Initially, it will be possible to detect a helicity-dependent asymmetry in triplet positronium formation of 1 part in 10,000. Improvements to better than 1 part in 100,000 should be attainable.

  5. The cryogenic source of slow monochromatic positrons

    International Nuclear Information System (INIS)

    Meshkov, I.N.; Pavlov, V.N.; Sidorin, A.O.; Yakovenko, S.L.

    2008-01-01

    The cryogenic source of slow monochromatic positrons based on the 22 Na isotope has been designed and constructed at JINR. Positrons emitted from radioactive source 22 Na have a very broad energy spectrum up to 0.5 MeV. To generate monochromatic beam of slow positrons the solid neon is used as a moderator. The solid neon allows forming slow positron beam of the energy of 1.2 eV at the spectrum width of 1 eV. The efficiency of moderation is 1 % of total positron flux

  6. Surface sealing using self-assembled monolayers and its effect on metal diffusion in porous low-k dielectrics studied using monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira, E-mail: uedono.akira.gb@u.tsukuba.ac.jp [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Armini, Silvia; Zhang, Yu [IMEC, Kapeldreef 75, B-3001 Heverlee, Leuven (Belgium); Kakizaki, Takeaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle, 06099 Halle (Germany); Anwand, Wolfgang; Wagner, Andreas [Institute for Radiation Physics, Helmholtz-Zentrum Dresden-Rossendorf, 01314 Dresden (Germany)

    2016-04-15

    Graphical abstract: - Highlights: • Pores with cubic pore side lengths of 1.1 and 3.1 nm coexisted in the low-k film. • For the sample without the SAM sealing process, metal atoms diffused from the top Cu/MnN layer into the OSG film and were trapped by the pores. Almost all pore interiors were covered by those metals. • For the sample damaged by a plasma etch treatment before the SAM sealing process, self-assembled molecules diffused into the OSG film, and they were preferentially trapped by larger pores. - Abstract: Surface sealing effects on the diffusion of metal atoms in porous organosilicate glass (OSG) films were studied by monoenergetic positron beams. For a Cu(5 nm)/MnN(3 nm)/OSG(130 nm) sample fabricated with pore stuffing, C{sub 4}F{sub 8} plasma etch, unstuffing, and a self-assembled monolayer (SAM) sealing process, it was found that pores with cubic pore side lengths of 1.1 and 3.1 nm coexisted in the OSG film. For the sample without the SAM sealing process, metal (Cu and Mn) atoms diffused from the top Cu/MnN layer into the OSG film and were trapped by the pores. As a result, almost all pore interiors were covered with those metals. For the sample damaged by an Ar/C{sub 4}F{sub 8} plasma etch treatment before the SAM sealing process, SAMs diffused into the OSG film, and they were preferentially trapped by larger pores. The cubic pore side length in these pores containing self-assembled molecules was estimated to be 0.7 nm. Through this work, we have demonstrated that monoenergetic positron beams are a powerful tool for characterizing capped porous films and the trapping of atoms and molecules by pores.

  7. Improved source and transport of monoenergetic MeV positrons

    Science.gov (United States)

    Selim, F. A.; Hunt, A. W.; Golovchenko, J. A.; Howell, R. H.; Haakenaasen, R.; Lynn, K. G.

    2000-08-01

    A new monoenergetic MeV positron beam source was designed and constructed at the Lawrence Livermore National Laboratory (LLNL) positron facility. The positron source provides a low emittance beam with high energy resolution for channeling, scattering, and in-flight annihilation experiments. New beam optics for extracting slow positrons from a moderator mounted in a Pelletron electrostatic accelerator is presented. A beam line was designed and constructed to energy analyze the output of the accelerator and to provide adjustable size and angular divergence beams to a target station. A post target large angle acceptance magnet separates positrons transmitted through the target from forward gamma ray emission.

  8. Atomic collisions involving pulsed positrons

    DEFF Research Database (Denmark)

    Merrison, J. P.; Bluhme, H.; Field, D.

    2000-01-01

    Conventional slow positron beams have been widely and profitably used to study atomic collisions and have been instrumental in understanding the dynamics of ionization. The next generation of positron atomic collision studies are possible with the use of charged particle traps. Not only can large...... instantaneous intensities be achieved with in-beam accumulation, but more importantly many orders of magnitude improvement in energy and spatial resolution can be achieved using positron cooling. Atomic collisions can be studied on a new energy scale with unprecedented precion and control. The use...

  9. Generation and application of slow positrons based on a electron LINAC

    CERN Document Server

    Kurihara, T

    2002-01-01

    History of slow positron in Institute of Materials Structure Science High Energy Accelerator Research Organization is explained. The principle of generation and application of intense positron beam is mentioned. Two sources of intense positron are radioactive decay of radioactive isotopes emitting positron and electron-positron pair creation. The radioactive decay method uses sup 5 sup 8 Co, sup 6 sup 4 Cu, sup 1 sup 1 C, sup 1 sup 3 N, sup 1 sup 5 O and sup 1 sup 8 F. The electron-positron pair creation method uses nuclear reactor or electron linear accelerator (LINAC). The positron experimental facility in this organization consists of electron LINAC, slow positron beam source, positron transport and experimental station. The outline of this facility is started. The intense slow positron beam is applied to research positronium work function, electron structure of surface. New method such as combination of positron lifetime measurement and slow positron beam or Auger electron spectroscopy by positron annihil...

  10. Development of highly polished, grazing incidence mirrors for synchrotron radiation beam lines at SSRL

    International Nuclear Information System (INIS)

    Tirsell, K.G.; Berglin, E.J.; Fuchs, B.A.; Holdener, F.R.; Humpal, H.H.; Karpenko, V.P.; Kulkarni, S.; Fantone, S.D.

    1987-08-01

    New platinum-coated grazing incidence mirrors with low surface roughnesses have been developed to focus bending magnet radiation from the SSRL/SLAC SPEAR storage ring on the entrance slits of two Beam Line VIII grating monochromators. The first mirror in the toroidal grating monochromator (TGM) branch is a cooled SiC cylinder capable of absorbing synchrotron radiation power levels of up to 260 watts without excessive distortion. This mirror deflects the beam vertically through a 12/degree/ angle and focuses it sagitally on the TGM entrance slit plane. The second TGM optical element is a fused-silica spherical mirror with a large radius of curvature that deflects the beam vertically through an additional 12/degree/ and focuses it tangentially with 3/1 demagnification. The first mirror in our spherical grating branch is a 5/degree/-vertically deflecting, cooled SiC toroid designed to focus tangentially on the monochromator entrance slits and sagitally in the exit slits. A 4/degree/-deflecting fused silica mirror is used after the exit sites in each beam line to refocus on to the sample. For this application a thin cylinder is bent to approximate an ellipsoid. The mirrors are now installed at SSRL and performance measurements are planned. Qualitatively the focus of the TGM optics at the entrance slit plane appears very good. In this paper we discuss considerations leading to the choice of SiC for each of the two first mirrors. We present highlights of the development of these mirrors with some emphasis on SiC polishing techniques. In addition, the specialized metrology developed to produce the more difficult figure of the toroid will be described. Measured surface roughness and figure results will be presented. 19 refs., 11 figs

  11. Development of highly polished, grazing incidence mirrors for synchrotron radiation beam lines at SSRL

    Energy Technology Data Exchange (ETDEWEB)

    Tirsell, K.G.; Berglin, E.J.; Fuchs, B.A.; Holdener, F.R.; Humpal, H.H.; Karpenko, V.P.; Kulkarni, S.; Fantone, S.D.

    1987-08-01

    New platinum-coated grazing incidence mirrors with low surface roughnesses have been developed to focus bending magnet radiation from the SSRL/SLAC SPEAR storage ring on the entrance slits of two Beam Line VIII grating monochromators. The first mirror in the toroidal grating monochromator (TGM) branch is a cooled SiC cylinder capable of absorbing synchrotron radiation power levels of up to 260 watts without excessive distortion. This mirror deflects the beam vertically through a 12/degree/ angle and focuses it sagitally on the TGM entrance slit plane. The second TGM optical element is a fused-silica spherical mirror with a large radius of curvature that deflects the beam vertically through an additional 12/degree/ and focuses it tangentially with 3/1 demagnification. The first mirror in our spherical grating branch is a 5/degree/-vertically deflecting, cooled SiC toroid designed to focus tangentially on the monochromator entrance slits and sagitally in the exit slits. A 4/degree/-deflecting fused silica mirror is used after the exit sites in each beam line to refocus on to the sample. For this application a thin cylinder is bent to approximate an ellipsoid. The mirrors are now installed at SSRL and performance measurements are planned. Qualitatively the focus of the TGM optics at the entrance slit plane appears very good. In this paper we discuss considerations leading to the choice of SiC for each of the two first mirrors. We present highlights of the development of these mirrors with some emphasis on SiC polishing techniques. In addition, the specialized metrology developed to produce the more difficult figure of the toroid will be described. Measured surface roughness and figure results will be presented. 19 refs., 11 figs.

  12. Second crossover energy of insulating materials using stationary electron beam under normal incidence

    Energy Technology Data Exchange (ETDEWEB)

    Rau, E.I. [Institute of Microelectronics Technology of Russian Academy of Science, 142432 Chernogolovka, Moscow District (Russian Federation)], E-mail: rau@phys.msu.ru; Fakhfakh, S. [LaMaCop, Faculte des Sciences, Route Soukra km 3, BP 802, CP 3018 Sfax (Tunisia); Andrianov, M.V.; Evstafeva, E.N. [Institute of Microelectronics Technology of Russian Academy of Science, 142432 Chernogolovka, Moscow District (Russian Federation); Jbara, O. [UTAP/LASSI, EA 3802, Faculte des Sciences, BP 1039, 51687 Reims Cedex 2 (France)], E-mail: omar.jbara@univ-reims.fr; Rondot, S.; Mouze, D. [UTAP/LASSI, EA 3802, Faculte des Sciences, BP 1039, 51687 Reims Cedex 2 (France)

    2008-03-15

    The purpose of this paper is to give some aspects of charging effects on dielectric materials submitted to continuous electron beam irradiation in a scanning electron microscope (SEM). When the dielectric is irradiated continuously, the so-called total yield approach (TYA) used to predict the sign of the charge appeared on electron irradiated insulators fails because the charge accumulated in the dielectric interferes with the electrons emission processes. Based on previous experimental and theoretical works found in the literature, an analysis of the evolution of the electron yield curves {sigma} = f(E{sub 0}) of insulators during irradiation is given. The aim of this work is firstly to determine experimentally the second crossover energy E{sub 2C} under continuous electron irradiation (charging conditions) and secondly to demonstrate that the charge balance occurs at this beam energy and not at E{sub 2} the energy deduced from non-charging conditions (pulse primary electron beam experiments) as commonly asserted. It is however possible to apply the TYA by substituting the critical energy E{sub 2} for E{sub 2C}. The experimental procedure is based on simultaneous time dependent measurements of surface potential, leakage current and displacement current. The study underlines the difference between the landing energy of primary electrons E{sub L} at the steady state and the second crossover energy, E{sub 2C}, for charged samples. Some preliminary results are also obtained concerning the influence of the incident beam density on the energy E{sub 2C}. The samples used for this study are PMMA, polycrystalline silicone dioxide (p-SiO{sub 2}), polycrystalline alumina (p-Al{sub 2}O{sub 3}) and soda lime glass (SLG)

  13. Second crossover energy of insulating materials using stationary electron beam under normal incidence

    International Nuclear Information System (INIS)

    Rau, E.I.; Fakhfakh, S.; Andrianov, M.V.; Evstafeva, E.N.; Jbara, O.; Rondot, S.; Mouze, D.

    2008-01-01

    The purpose of this paper is to give some aspects of charging effects on dielectric materials submitted to continuous electron beam irradiation in a scanning electron microscope (SEM). When the dielectric is irradiated continuously, the so-called total yield approach (TYA) used to predict the sign of the charge appeared on electron irradiated insulators fails because the charge accumulated in the dielectric interferes with the electrons emission processes. Based on previous experimental and theoretical works found in the literature, an analysis of the evolution of the electron yield curves σ = f(E 0 ) of insulators during irradiation is given. The aim of this work is firstly to determine experimentally the second crossover energy E 2C under continuous electron irradiation (charging conditions) and secondly to demonstrate that the charge balance occurs at this beam energy and not at E 2 the energy deduced from non-charging conditions (pulse primary electron beam experiments) as commonly asserted. It is however possible to apply the TYA by substituting the critical energy E 2 for E 2C . The experimental procedure is based on simultaneous time dependent measurements of surface potential, leakage current and displacement current. The study underlines the difference between the landing energy of primary electrons E L at the steady state and the second crossover energy, E 2C , for charged samples. Some preliminary results are also obtained concerning the influence of the incident beam density on the energy E 2C . The samples used for this study are PMMA, polycrystalline silicone dioxide (p-SiO 2 ), polycrystalline alumina (p-Al 2 O 3 ) and soda lime glass (SLG)

  14. Radiation emission and its influence on the motion of multi-GeV electrons and positrons incident on a single diamond crystal

    CERN Document Server

    Kirsebom, K; Uggerhøj, Erik; Elsener, K; Ballestrero, S; Sona, P; Connell, S H; Sellschop, J P Friedel; Vilakazi, Z Z

    2001-01-01

    A few years ago the CERN NA-43 collaboration installed an upgraded detector system which allows a detailed analysis of the particle motion before, during and after penetration of a crystal. Also, essentially perfect diamond crystals were produced by the collaborators from Schonland Research Centre. These facts have led to new and very detailed investigations of QED-processes in strong crystalline fields. Along axial directions the radiation emission is enhanced by more than two orders of magnitude. For incidence on a 0.7 mm thick diamond crystal of well-aligned 149 GeV electrons, 35% give rise to a high energy photon peak at approximately=120 GeV. For 243 GeV electrons and approximately=200 GeV photons, this number decreases to 25%-which may be an indication of quantum suppression. Different measurements of the photon multiplicities show that in most cases positrons and electrons emit equal number of photons. The dramatic radiation emission leads to a strong reduction in transverse energy and all electrons in...

  15. KEK-IMSS Slow Positron Facility

    Science.gov (United States)

    Hyodo, T.; Wada, K.; Yagishita, A.; Kosuge, T.; Saito, Y.; Kurihara, T.; Kikuchi, T.; Shirakawa, A.; Sanami, T.; Ikeda, M.; Ohsawa, S.; Kakihara, K.; Shidara, T.

    2011-12-01

    The Slow Positron Facility at the Institute of Material Structure Science (IMSS) of High Energy Accelerator Research Organization (KEK) is a user dedicated facility with an energy tunable (0.1 - 35 keV) slow positron beam produced by a dedicated 55MeV linac. The present beam line branches have been used for the positronium time-of-flight (Ps-TOF) measurements, the transmission positron microscope (TPM) and the photo-detachment of Ps negative ions (Ps-). During the year 2010, a reflection high-energy positron diffraction (RHEPD) measurement station is going to be installed. The slow positron generator (converter/ moderator) system will be modified to get a higher slow positron intensity, and a new user-friendly beam line power-supply control and vacuum monitoring system is being developed. Another plan for this year is the transfer of a 22Na-based slow positron beam from RIKEN. This machine will be used for the continuous slow positron beam applications and for the orientation training of those who are interested in beginning researches with a slow positron beam.

  16. Compensation of errors due to incident beam drift in a 3 DOF measurement system for linear guide motion.

    Science.gov (United States)

    Hu, Pengcheng; Mao, Shuai; Tan, Jiu-Bin

    2015-11-02

    A measurement system with three degrees of freedom (3 DOF) that compensates for errors caused by incident beam drift is proposed. The system's measurement model (i.e. its mathematical foundation) is analyzed, and a measurement module (i.e. the designed orientation measurement unit) is developed and adopted to measure simultaneously straightness errors and the incident beam direction; thus, the errors due to incident beam drift can be compensated. The experimental results show that the proposed system has a deviation of 1 μm in the range of 200 mm for distance measurements, and a deviation of 1.3 μm in the range of 2 mm for straightness error measurements.

  17. Dynamic grazing incidence fast atom diffraction during molecular beam epitaxial growth of GaAs

    International Nuclear Information System (INIS)

    Atkinson, P.; Eddrief, M.; Etgens, V. H.; Khemliche, H.; Debiossac, M.; Mulier, M.; Lalmi, B.; Roncin, P.; Momeni, A.

    2014-01-01

    A Grazing Incidence Fast Atom Diffraction (GIFAD) system has been mounted on a commercial molecular beam epitaxy chamber and used to monitor GaAs growth in real-time. In contrast to the conventionally used Reflection High Energy Electron Diffraction, all the GIFAD diffraction orders oscillate in phase, with the change in intensity related to diffuse scattering at step edges. We show that the scattered intensity integrated over the Laue circle is a robust method to monitor the periodic change in surface roughness during layer-by-layer growth, with oscillation phase and amplitude independent of incidence angle and crystal orientation. When there is a change in surface reconstruction at the start of growth, GIFAD intensity oscillations show that there is a corresponding delay in the onset of layer-by-layer growth. In addition, changes in the relative intensity of different diffraction orders have been observed during growth showing that GIFAD has the potential to provide insight into the preferential adatom attachment sites on the surface reconstruction during growth.

  18. Measurement of e+p neutral current deep inelastic scattering with a longitudinally polarised positron beam and X-ray radiation damage for silicon sensors

    International Nuclear Information System (INIS)

    Januschek, Friederike

    2011-01-01

    The cross sections for Neutral Current e + p Deep Inelastic Scattering (NC DIS) with longitudinally polarised positron beams were measured at a centre-of-mass energy √(s)=318 GeV using the ZEUS detector at HERA. Single-differential cross sections as a function of the virtuality of the exchanged boson, Q 2 , of the inelasticity, y, and of the Bjorken scaling variable, x, and reduced cross sections (as a function of x and Q 2 ) were measured in the phase space region defined as Q 2 >185 GeV 2 , y 2 >0.004. The results, based on data corresponding to an integrated luminosity of 135.5 pb -1 , are given for zero polarisation for the whole sample, as well as for both positive and negative values of the longitudinal polarisation of the positron beam. The measured cross sections are compared to the predictions of the Standard Model. The proton structure function xF 3 is measured and the interference term xF γZ 3 is extracted as a function of x at Q 2 =1500 GeV 2 by extrapolating the measurements done at different Q 2 values. The presented measurements of the polarised e + p NC DIS cross sections, the xF 3 structure function and the xF γZ 3 interference term exceed the precision of previous ZEUS measurements. The uncertainties of the Parton Density Functions (PDFs) for the gluon and the u-valence quark are expected to be reduced at high-x values when the presented results are included in the PDF fits of the proton. A study is presented to further reduce PDF uncertainties for the gluon at very high x (above 10 -1 ) through the inclusion of DIS dijet cross sections in a ZEUS-JETS-like PDF fit. An irradiation facility to study the X-ray-induced radiation damage of silicon sensors for the European XFEL was set up at HASYLAB. Nine gate-controlled diodes were irradiated with doses from 1 kGy to 1 GGy in several irradiation steps and the surface current I surf and the flatband voltage V fb were measured after each irradiation. It was found that both, I surf and V fb , strongly

  19. Malfunctions of Implantable Cardiac Devices in Patients Receiving Proton Beam Therapy: Incidence and Predictors

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Daniel R., E-mail: dgomez@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Poenisch, Falk [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Pinnix, Chelsea C. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Sheu, Tommy [Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Chang, Joe Y. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Memon, Nada [Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mohan, Radhe [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rozner, Marc A. [Department of Anesthesiology and Perioperative Medicine, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Dougherty, Anne H. [Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2013-11-01

    Purpose: Photon therapy has been reported to induce resets of implanted cardiac devices, but the clinical sequelae of treating patients with such devices with proton beam therapy (PBT) are not well known. We reviewed the incidence of device malfunctions among patients undergoing PBT. Methods and Materials: From March 2009 through July 2012, 42 patients with implanted cardiac implantable electronic devices (CIED; 28 pacemakers and 14 cardioverter-defibrillators) underwent 42 courses of PBT for thoracic (23, 55%), prostate (15, 36%), liver (3, 7%), or base of skull (1, 2%) tumors at a single institution. The median prescribed dose was 74 Gy (relative biological effectiveness; range 46.8-87.5 Gy), and the median distance from the treatment field to the CIED was 10 cm (range 0.8-40 cm). Maximum proton and neutron doses were estimated for each treatment course. All CIEDs were checked before radiation delivery and monitored throughout treatment. Results: Median estimated peak proton and neutron doses to the CIED in all patients were 0.8 Gy (range 0.13-21 Gy) and 346 Sv (range 11-1100 mSv). Six CIED malfunctions occurred in 5 patients (2 pacemakers and 3 defibrillators). Five of these malfunctions were CIED resets, and 1 patient with a defibrillator (in a patient with a liver tumor) had an elective replacement indicator after therapy that was not influenced by radiation. The mean distance from the proton beam to the CIED among devices that reset was 7.0 cm (range 0.9-8 cm), and the mean maximum neutron dose was 655 mSv (range 330-1100 mSv). All resets occurred in patients receiving thoracic PBT and were corrected without clinical incident. The generator for the defibrillator with the elective replacement indicator message was replaced uneventfully after treatment. Conclusions: The incidence of CIED resets was about 20% among patients receiving PBT to the thorax. We recommend that PBT be avoided in pacing-dependent patients and that patients with any type of CIED receiving

  20. Malfunctions of Implantable Cardiac Devices in Patients Receiving Proton Beam Therapy: Incidence and Predictors

    International Nuclear Information System (INIS)

    Gomez, Daniel R.; Poenisch, Falk; Pinnix, Chelsea C.; Sheu, Tommy; Chang, Joe Y.; Memon, Nada; Mohan, Radhe; Rozner, Marc A.; Dougherty, Anne H.

    2013-01-01

    Purpose: Photon therapy has been reported to induce resets of implanted cardiac devices, but the clinical sequelae of treating patients with such devices with proton beam therapy (PBT) are not well known. We reviewed the incidence of device malfunctions among patients undergoing PBT. Methods and Materials: From March 2009 through July 2012, 42 patients with implanted cardiac implantable electronic devices (CIED; 28 pacemakers and 14 cardioverter-defibrillators) underwent 42 courses of PBT for thoracic (23, 55%), prostate (15, 36%), liver (3, 7%), or base of skull (1, 2%) tumors at a single institution. The median prescribed dose was 74 Gy (relative biological effectiveness; range 46.8-87.5 Gy), and the median distance from the treatment field to the CIED was 10 cm (range 0.8-40 cm). Maximum proton and neutron doses were estimated for each treatment course. All CIEDs were checked before radiation delivery and monitored throughout treatment. Results: Median estimated peak proton and neutron doses to the CIED in all patients were 0.8 Gy (range 0.13-21 Gy) and 346 Sv (range 11-1100 mSv). Six CIED malfunctions occurred in 5 patients (2 pacemakers and 3 defibrillators). Five of these malfunctions were CIED resets, and 1 patient with a defibrillator (in a patient with a liver tumor) had an elective replacement indicator after therapy that was not influenced by radiation. The mean distance from the proton beam to the CIED among devices that reset was 7.0 cm (range 0.9-8 cm), and the mean maximum neutron dose was 655 mSv (range 330-1100 mSv). All resets occurred in patients receiving thoracic PBT and were corrected without clinical incident. The generator for the defibrillator with the elective replacement indicator message was replaced uneventfully after treatment. Conclusions: The incidence of CIED resets was about 20% among patients receiving PBT to the thorax. We recommend that PBT be avoided in pacing-dependent patients and that patients with any type of CIED receiving

  1. Toward a European Network of Positron Laboratories

    Directory of Open Access Journals (Sweden)

    Karwasz Grzegorz P.

    2015-12-01

    Full Text Available Some applications of controlled-energy positron beams in material studies are discussed. In porous organic polysilicates, measurements of 3γ annihilation by Doppler broadening (DB method at the Trento University allowed to trace pore closing and filling by water vapor. In silicon coimplanted by He+ and H+, DB data combined with positron lifetime measurements at the München pulsed positron beam allowed to explain Si blistering. Presently measured samples of W for applications in thermonuclear reactors, irradiated by W+ and electrons, show vast changes of positron lifetimes, indicating complex dynamics of defects.

  2. Depolarization in the ILC Linac-To-Ring Positron beamline

    Energy Technology Data Exchange (ETDEWEB)

    Kovalenko, Valentyn; Ushakov, Andriy [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Moortgat-Pick, Gudrid [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Riemann, Sabine [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2012-02-15

    To achieve the physics goals of future Linear Colliders, it is important that electron and positron beams are polarized. The positron source planned for the International Linear Collider (ILC) is based on a helical undulator system and can deliver a polarised beam with vertical stroke Pe{sup +} vertical stroke {>=} 60%. To ensure that no significant polarization is lost during the transport of the electron and positron beams from the source to the interaction region, spin tracking has to be included in all transport elements which can contribute to a loss of polarization. These are the positron source, the damping ring, the spin rotators, the main linac and the beam delivery system. In particular, the dynamics of the polarized positron beam is required to be investigated. The results of positron spin tracking and depolarization study at the Positron-Linac-To-Ring (PLTR) beamline are presented. (orig.)

  3. Generation of monoenergetic positrons

    International Nuclear Information System (INIS)

    Hulett, L.D. Jr.; Dale, J.M.; Miller, P.D. Jr.; Moak, C.D.; Pendyala, S.; Triftshaeuser, W.; Howell, R.H.; Alvarez, R.A.

    1983-01-01

    Many experiments have been performed in the generation and application of monoenergetic positron beams using annealed tungsten moderators and fast sources of 58 Co, 22 Na, 11 C, and LINAC bremstrahlung. This paper will compare the degrees of success from our various approaches. Moderators made from both single crystal and polycrystal tungsten have been tried. Efforts to grow thin films of tungsten to be used as transmission moderators and brightness enhancement devices are in progress

  4. Multiple scattering of a zero-order Bessel beam with arbitrary incidence by an aggregate of uniaxial anisotropic spheres

    International Nuclear Information System (INIS)

    Li, Z.J.; Wu, Z.S.; Qu, T.; Shang, Q.C.; Bai, L.

    2016-01-01

    Based on the generalized multiparticle Mie theory, multiple scattering of an aggregate of uniaxial anisotropic spheres illuminated by a zero-order Bessel beam (ZOBB) with arbitrary propagation direction is investigated. The particle size and configuration are arbitrary. The arbitrary incident Bessel beam is expanded in terms of spherical vector wave functions (SVWFs). Utilizing the vector addition theorem of SVWFs, interactive and total scattering coefficients are derived through the continuous boundary conditions on which the interaction of the particles is considered. The accuracy of the theory and codes are verified by comparing results with those obtained for arbitrary plane wave incidence by CST simulation, and for ZOBB incidence by a numerical method. The effects of angle of incidence, pseudo-polarization angle, half-conical angle, beam center position, and permittivity tensor elements on the radar cross sections (RCSs) of several types of collective uniaxial anisotropic spheres, such as a linear chain, a 4×4×4 cube-shaped array, and other periodical structures consisting of massive spheres, are numerically analyzed. Selected results on the properties of typical particles such as TiO 2 , SiO 2 , or other particle lattices are calculated. This investigation could provide an effective test for further research on the scattering characteristics of an aggregate of anisotropic spheres by a high-order Bessel vortex beam. The results have important application in optical tweezers and particle manipulation. - Highlights: • Scattering of Bessel beam by an aggregate of uniaxial anisotropic spheres is studied. • The zero-order Bessel beam propagates and polarizes along arbitrary direction. • The accuracy of expansion coefficients, the scattering theory and codes is verified. • Effects of various parameters on scattering properties are numerically discussed. • Scattering properties of several type of periodical array are numerically analyzed.

  5. Design of a transmission electron positron microscope

    International Nuclear Information System (INIS)

    Doyama, Masao; Inoue, M.; Kogure, Y.; Hayashi, Y.; Yoshii, T.; Kurihara, T.; Tsuno, K.

    2003-01-01

    This paper reports the plans and design of positron-electron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan. A used electron microscope is altered. The kinetic energies of positrons produced by accelerators or by nuclear decays are not a unique value but show a spread over in a wide range. Positron beam is guided to a transmission electron microscope (JEM100SX). Positrons are moderated by a tungsten foil, are accelerated and are focused on a nickel sheet. The monochromatic focused beam is injected into an electron microscope. The focusing and aberration of positrons are the same as electrons in a magnetic system which are used in commercial electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (author)

  6. Prototyping of the ILC Baseline Positron Target

    Energy Technology Data Exchange (ETDEWEB)

    Gronberg, J; Brooksby, C; Piggott, T; Abbott, R; Javedani, J; Cook, E

    2012-02-29

    The ILC positron system uses novel helical undulators to create a powerful photon beam from the main electron beam. This beam is passed through a titanium target to convert it into electron-positron pairs. The target is constructed as a 1 m diameter wheel spinning at 2000 RPM to smear the 1 ms ILC pulse train over 10 cm. A pulsed flux concentrating magnet is used to increase the positron capture efficiency. It is cooled to liquid nitrogen temperatures to maximize the flatness of the magnetic field over the 1 ms ILC pulse train. We report on prototyping effort on this system.

  7. Wideband converter of a charge of particle beam incident on a Faraday cylinder into a number of pulses

    International Nuclear Information System (INIS)

    Shchagin, A.V.; Lysenko, V.F.

    1985-01-01

    An electric circuit of a beam positive charge-pulse converter during beam incidence on a Faraday cylinder (conversion of Faraday cylinder current into F frequency, where F=10 10 J, where J - is the Faraday cylinder current) is described. Conversion ratio is 10 10 pulses/KP (10 10 Hz/A). Input current change limits are 10 -10 -10 -4 A. Conversion error is |ΔF| -3 F +0.1 Hz). ''Dead'' time is absent. Input resistance of the converter is close to zero

  8. Measurement of e{sup +}p neutral current deep inelastic scattering with a longitudinally polarised positron beam and X-ray radiation damage for silicon sensors

    Energy Technology Data Exchange (ETDEWEB)

    Januschek, Friederike

    2012-05-15

    The cross sections for Neutral Current e{sup +}p Deep Inelastic Scattering (NC DIS) with longitudinally polarised positron beams were measured at a centre-of-mass energy {radical}(s)=318 GeV using the ZEUS detector at HERA. Single-differential cross sections as a function of the virtuality of the exchanged boson, Q{sup 2}, of the inelasticity, y, and of the Bjorken scaling variable, x, and reduced cross sections (as a function of x and Q{sup 2}) were measured in the phase space region defined as Q{sup 2}>185 GeV{sup 2}, y<0.9 and y(1-x){sup 2}>0.004. The results, based on data corresponding to an integrated luminosity of 135.5 pb{sup -1}, are given for zero polarisation for the whole sample, as well as for both positive and negative values of the longitudinal polarisation of the positron beam. The measured cross sections are compared to the predictions of the Standard Model. The proton structure function xF{sub 3} is measured and the interference term xF{sup {gamma}}{sup Z}{sub 3} is extracted as a function of x at Q{sup 2}=1500 GeV{sup 2} by extrapolating the measurements done at different Q{sup 2} values. The presented measurements of the polarised e{sup +}p NC DIS cross sections, the xF{sub 3} structure function and the xF{sup {gamma}}{sup Z}{sub 3} interference term exceed the precision of previous ZEUS measurements. The uncertainties of the Parton Density Functions (PDFs) for the gluon and the u-valence quark are expected to be reduced at high-x values when the presented results are included in the PDF fits of the proton. A study is presented to further reduce PDF uncertainties for the gluon at very high x (above 10{sup -1}) through the inclusion of DIS dijet cross sections in a ZEUS-JETS-like PDF fit. An irradiation facility to study the X-ray-induced radiation damage of silicon sensors for the European XFEL was set up at HASYLAB. Nine gate-controlled diodes were irradiated with doses from 1 kGy to 1 GGy in several irradiation steps and the surface current I

  9. Vacancy behavior in Cu(In{sub 1−x}Ga{sub x})Se{sub 2} layers grown by a three-stage coevaporation process probed by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Islam, Muhammad M.; Sakurai, Takeaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Hugenschmidt, Christoph [Physics Department E21 and Heinz Maier-Leibnitz Zentrum (MLZ), Technische Universität München, 85748 Garching (Germany); Egger, Werner [Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik, 85577 Neubiberg (Germany); Scheer, Roland; Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle, 06099 Halle (Germany); Akimoto, Katsuhiro [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan)

    2016-03-31

    Vacancy-type defects in Cu(In{sub 1−x}Ga{sub x})Se{sub 2} (x ≅ 0.45 and 1) grown by a three-stage coevaporation process were probed using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and positron lifetime spectra showed that two different defect species coexist in the Cu(In{sub 1−x}Ga{sub x})Se{sub 2} layers, and these were identified as mono/divacancy-type defects and vacancy clusters, respectively. The vacancy clusters were mainly introduced during the third growth stage, and were located in the subsurface region. The concentration of the defects affected the short-circuit current density and the conversion efficiency of the solar cells. The defect concentration and their depth distributions varied depending on Se beam equivalent pressure, growth time, and post-growth annealing time. The behavior of the vacancy-type defects is discussed also with respect to results obtained using an electron probe micro-analyzer. - Highlights: • We applied positron annihilation to characterize Cu(In{sub 1−x}Ga{sub x})Se{sub 2}. • Defect species were identified as mono/divacancy-type defects and vacancy clusters. • The conversion efficiency increased with a decreasing vacancy concentration.

  10. QCD and electroweak analysis and first measurement of neutral and charged current cross section with the polarised positron beam at HERA 2

    International Nuclear Information System (INIS)

    Portheault, B.

    2005-03-01

    In 2003-2004 the HERA collider delivered e + p collisions with a longitudinally polarised positron beam. We prescribe the measurement of inclusive Neutral and Charged Current DIS (deep inelastic scattering) cross section using the H1 detector. The total Charged Current cross section for Q 2 > 400 GeV 2 , y -1 and a Left-handed (P = -0,40) sample of 21,7 pb -1 yielding σcc (P = +0,33) = 34,67 pb ± 1,94 pb (stat) ± 1,66 pb (sys) C.20) σcc(P = -0,40) = 13,80 pb ± 1,04 pb (stat) ± 0,94 pb (sys). C.21) This result is consistent with the proportionality of the cross section with respect to the polarisation, in good agreement with the Standard Model expectations. The second part of this work is devoted to QCD analysis of the proton structure. The H1 data alone are used to extract flavor separated parton densities. This analysis is further used as a basis to extract various electroweak parameters, such as the W boson mass and the quarks couplings to the Z. Then a global QCD analysis of DIS and Drell Yan data is realized, focusing on the strange sea asymmetry which is found to be small: ∫ 0 1 x(s - s-bar)dx = (1,8 ± 3,8) x 10 -4 . The impact of new E866 data on high x partons densities is discussed and the extraction of the strong coupling is realized αs = 0,1197 ± (+0,0005 - 0,0007)(mod) ±0,006 (th). (author)

  11. PLEPS: Pulsed low energy positron system

    Directory of Open Access Journals (Sweden)

    Werner Egger

    2015-08-01

    Full Text Available PLEPS, operated by the Universität der Bundeswehr München, located at NEPOMUC, is a unique tool for depth profiling of defects with positron annihilation lifetime spectroscopy using a pulsed positron beam of variable energy.

  12. NEPOMUC: Neutron induced positron source Munich

    Directory of Open Access Journals (Sweden)

    Christoph Hugenschmidt

    2015-08-01

    Full Text Available NEPOMUC, operated by the Technische Universität München and the Universität der Bundeswehr München, provides a high-intensity low-energy positron beam for applications in solid state and surface physics as well as for fundamental research in nuclear and atomic physics. The intensity amounts to > 109 moderated positrons per second at a beam energy of E = 1 keV.

  13. A transmission positron microscope and a scanning positron microscope being built at KEK, Japan

    International Nuclear Information System (INIS)

    Doyama, M.; Inoue, M.; Kogure, Y.; Kurihara, T.; Yagishita, A.; Shidara, T.; Nakahara, K.; Hayashi, Y.; Yoshiie, T.

    2001-01-01

    This paper reports the plans of positron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan improving used electron microscopes. The kinetic energies of positron produced by accelerators or by nuclear decays have not a unique value but show a spread over in a wide range. Positron beam will be guided near electron microscopes, a transmission electron microscope (JEM100S) and a scanning electron microscope (JSM25S). Positrons are slowed down by a tungsten foil, accelerated and focused on a nickel sheet. The monochromatic focused beam will be injected into an electron microscope. The focusing of positrons and electrons is achieved by magnetic system of the electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (orig.)

  14. Beam test of CSES silicon strip detector module

    Science.gov (United States)

    Zhang, Da-Li; Lu, Hong; Wang, Huan-Yu; Li, Xin-Qiao; Xu, Yan-Bing; An, Zheng-Hua; Yu, Xiao-xia; Wang, Hui; Shi, Feng; Wang, Ping; Zhao, Xiao-Yun

    2017-05-01

    The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. A low-noise analog ASIC VA140 was used in this study for DSSD signal readout. A beam test on the DSSD module was performed at the Beijing Test Beam Facility of the Beijing Electron Positron Collider (BEPC) using a 400-800 MeV/c proton beam. The pedestal analysis results, RMSE noise, gain correction, and intensity distribution of incident particles of the DSSD module are presented. Supported by the XXX Civil Space Programme

  15. A positron accumulator for antihydrogen synthesis

    CERN Document Server

    Jørgensen, L V; Fine, K S; Watson, T L; Van der Werf, D P; Charlton, M

    2001-01-01

    A positron accumulator based on the modified Penning-Malmberg design of Surko and co-workers at UCSD has been constructed and undergone testing in preparation for the ATHENA experiment now under way at CERN. This experiment aims to produce and characterize atomic anti- hydrogen. The positron accumulator utilises nitrogen buffer gas to cool and trap a continuous beam of positrons emanating from a /sup 22 /Na radioactive source. A solid neon moderator slows the positrons from the source down to epithermal energies of a few eV before being injected into the trap. It is estimated that around 10/sup 7/ positrons can be trapped and cooled to ambient temperature within a couple of minutes in this scheme using a 6 mCi source. Preliminary tests have so far demonstrated trapping of approximately 3*10/sup 6/ positrons and an efficiency of the Ne moderator of nearly 1%. (8 refs).

  16. Positron annihilation induced Auger electron spectroscopy

    Science.gov (United States)

    Weiss, Alex; Koymen, A. R.; Mehl, David; Jensen, K. O.; Lei, Chun; Lee, K. H.

    1990-01-01

    Recently, Weiss et al. have demonstrated that it is possible to excite Auger transitions by annihilating core electrons using a low energy (less than 30eV) beam of positrons. This mechanism makes possible a new electron spectroscopy, Positron annihilation induced Auger Electron Spectroscopy (PAES). The probability of exciting an Auger transition is proportional to the overlap of the positron wavefunction with atomic core levels. Since the Auger electron energy provides a signature of the atomic species making the transition, PAES makes it possible to determine the overlap of the positron wavefunction with a particular element. PAES may therefore provide a means of detecting positron-atom complexes. Measurements of PAES intensities from clean and adsorbate covered Cu surfaces are presented which indicate that approx. 5 percent of positrons injected into CU at 25eV produce core annihilations that result in Auger transitions.

  17. A code to determine the energy distribution, the incident energy and the flux of a beam of light ions into a stack of foils

    International Nuclear Information System (INIS)

    Sonzogni, A.A.; Romo, A.S.M.A.; Frosch, W.R.; Nassiff, S.J.

    1992-01-01

    The stacked-foil technique is one of the most used methods to obtain excitation functions of nuclear reactions using light ions as projectiles. The purpose of this program is the calculation of the energy of the beam in the stack, as well as to obtain the incident energy and the flux of the beam by using monitor excitation functions. (orig.)

  18. Role of vibrational dynamics in resonant positron annihilation on molecules.

    Science.gov (United States)

    Jones, A C L; Danielson, J R; Natisin, M R; Surko, C M

    2013-05-31

    Vibrational Feshbach resonances are dominant features of positron annihilation for incident positron energies in the range of the molecular vibrations. Studies in relatively small molecules are described that elucidate the role of intramolecular vibrational energy redistribution into near-resonant multimode states, and the subsequent coupling of these modes to the positron continuum, in suppressing or enhancing these resonances. The implications for annihilation in other molecular species, and the necessary ingredients of a more complete theory of resonant positron annihilation, are discussed.

  19. Study of a positron generation

    International Nuclear Information System (INIS)

    Nakahara, Kazuo; Enomoto, A.; Ikeda, M.; Ohsawa, S.; Kamitani, T.; Hosoyama, K.; Takei, H.; Emoto, T.; Tani, S.

    1998-03-01

    In the Power Reactor and Nuclear Fuel Development Corporation (PNC), the following are examined as part of an application technology using a high power electron linac: monochromatic gamma ray sources, free electron lasers, and intense positron sources. This report presents the study of an intense positron source, which has been developed jointly by High Energy Accelerator Research Organization (KEK) and PNC. In this report, we describe following items for an adaptive estimate of a superconducting magnet in order to efficiently converge a positron beam. (1) The cryostat which included the superconducting magnet is manufactured. (2) An excitement test of the superconducting magnet is carried out with a magnetic substance such as the electromagnet yoke. (author)

  20. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities

    International Nuclear Information System (INIS)

    Fondevila, Damian; Arbiser, Silvio; Sansogne, Rosana; Brunetto, Monica; Dosoretz, Bernardo

    2008-01-01

    Primary barrier determinations for the shielding of medical radiation therapy facilities are generally made assuming normal beam incidence on the barrier, since this is geometrically the most unfavorable condition for that shielding barrier whenever the occupation line is allowed to run along the barrier. However, when the occupation line (for example, the wall of an adjacent building) runs perpendicular to the barrier (especially roof barrier), then two opposing factors come in to play: increasing obliquity angle with respect to the barrier increases the attenuation, while the distance to the calculation point decreases, hence, increasing the dose. As a result, there exists an angle (α max ) for which the equivalent dose results in a maximum, constituting the most unfavorable geometric condition for that shielding barrier. Based on the usual NCRP Report No. 151 model, this article presents a simple formula for obtaining α max , which is a function of the thickness of the barrier (t E ) and the equilibrium tenth-value layer (TVL e ) of the shielding material for the nominal energy of the beam. It can be seen that α max increases for increasing TVL e (hence, beam energy) and decreases for increasing t E , with a range of variation that goes from 13 to 40 deg for concrete barriers thicknesses in the range of 50-300 cm and most commercially available teletherapy machines. This parameter has not been calculated in the existing literature for radiotherapy facilities design and has practical applications, as in calculating the required unoccupied roof shielding for the protection of a nearby building located in the plane of the primary beam rotation

  1. Peculiarities of the Self-Action of Inclined Wave Beams Incident on a Discrete System of Optical Fibers

    Science.gov (United States)

    Litvak, A. G.; Mironov, V. A.; Skobelev, S. A.; Smirnov, L. A.

    2018-01-01

    Based on a discrete nonlinear Schrödinger equation (DNSE), we studied analytically and numerically the peculiarities of the self-action of one-dimensional quasi-optic wave beams injected into a spatially inhomogeneous medium consisting of a set of equidistant mutually coupled optical fibers. A variational approach allowing the prediction of the global evolution of localized fields with the initially plane phase front was developed. The self-consistent equations are obtained for the main parameters of such beams (the position of the center of mass, the effective width, and linear and quadratic phase-front corrections) in the aberrationless approximation. The case of radiation incident on a periodic system of nonlinear optical fibers at an angle to the axis oriented along them is analyzed in detail. It is shown that for the radiation power exceeding a critical value, the self-focusing of the wave field is observed, which is accompanied by the shift of the intensity maximum followed by the concentration of the main part of radiation only in one of the structural elements of the array under study. In this case, the beams propagate along paths considerably different from linear and the direction of their propagation changes compared to the initial direction. Asymptotic expressions are found that allow us to estimate the self-focusing length and to determine quite accurately the final position of a point with the maximum field amplitude after radiation trapping a channel. The results of the qualitative study of the possible self-channeling regimes for wave beams in a system of weakly coupled optical fibers in the aberrationless approximation are compared with the results of direct numerical simulations within the DNSE framework.

  2. Low energy positron scattering from helium

    International Nuclear Information System (INIS)

    Sullivan, J.P.; Jones, A.; Caradonna, P.; Makochekanwa, C.; Buckman, S.J.

    2008-01-01

    A new experiment has been developed for high resolution studies of positron scattering from atoms and molecules. Based on the Surko trap technology, a pulsed positron beam has been used to obtain preliminary measurements of low energy, differential elastic scattering cross sections from helium. The operation of the beamline is described and preliminary absolute cross section values for scattering energies of 5, 10 and 15 eV are presented and compared with contemporary theoretical calculations

  3. Development of Texas intense positron source

    International Nuclear Information System (INIS)

    Koeymen, A.R.; Uenlue, K.; Jacobsen, F.M.; Goektepeli, S.; Wehring, B.W.

    1999-01-01

    The Texas Intense Positron Source (TIPS) is a reactor-based low-energy positron beam facility utilizing some novel techniques in positron beam production. This facility will be located at the University of Texas (UT) at Austin Nuclear Engineering Teaching Laboratory (NETL) and is being developed by UT Austin and UT Arlington researchers. TIPS will use a large area (total area of 900-1800 cm 2 ) 64 Cu source to supply fast β + particles for subsequent moderation to form an intense monoenergetic positron beam in the energy range of 0-50 keV with an expected intensity of 10 8 e + /s. Natural copper will be neutron activated near the core of the NETL 1 MW TRIGA Mark II research reactor to produce the 64 Cu isotope. The activated source will be transported to the moderator/remoderator assembly, outside the biological shield of the reactor. This assembly combines the primary moderation and posterior remoderation of the fast β + particles into one stage using solid Kr to produce a low-energy positron source of a few eV with a diameter of 8 mm. The low-energy positron beam is then extracted by an electrostatic modified SOA gun and after further acceleration to 5 keV, the beam is focused onto the object slit of a 90 deg. bending magnet. After further focusing and another 90 deg. bend, the beam enters the main accelerator/decelerator that transports the beam onto the target for experimentation. The components of TIPS have been manufactured and are currently being optimized. In this communication we present some of the details of the TIPS facility and furthermore briefly discuss its intended applications

  4. Diagnosis of secondary caries in esthetic restorations: influence of the incidence vertical angle of the X-ray beam.

    Science.gov (United States)

    Moreira, Patrícia Lima; Messora, Michel Reis; Pereira, Stela Márcia; Almeida, Solange Maria de; Cruz, Adriana Dibo da

    2011-01-01

    The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (A(z)), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (A(z)=0.66, Filtek-Z250>A(z)=0.56, TPH-Spectrum) compared to 0º (A(z)=0.55, Charisma>A(z)=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.

  5. Optimal design and fabrication method for antireflection coatings for P-polarized 193 nm laser beam at large angles of incidence (68°-74°).

    Science.gov (United States)

    Jin, Jingcheng; Jin, Chunshui; Li, Chun; Deng, Wenyuan; Chang, Yanhe

    2013-09-01

    Most of the optical axes in modern systems are bent for optomechanical considerations. Antireflection (AR) coatings for polarized light at oblique incidence are widely used in optical surfaces like prisms or multiform lenses to suppress undesirable reflections. The optimal design and fabrication method for AR coatings with large-angle range (68°-74°) for a P-polarized 193 nm laser beam is discussed in detail. Experimental results showed that after coating, the reflection loss of a P-polarized laser beam at large angles of incidence on the optical surfaces is reduced dramatically, which could greatly improve the output efficiency of the optical components in the deep ultraviolet vacuum range.

  6. Effect of radiation damage on luminescence of erbium-implanted SiO sub 2 /Si studied by slow positron beam

    CERN Document Server

    Kawasuso, A; Hirata, K; Sekiguchi, T; Kobayashi, Y; Okada, S

    2000-01-01

    The effect of damage on 1.54 mu m luminescence for 30 keV-Er-implanted SiO sub 2 films has been studied by positron annihilation and cathodoluminescence. It was found that S-parameter in the films decreased after implantation, indicating the suppression of positronium formation. The luminescence appeared with the recovery of the S-parameter after 600 deg. C annealing. The intensity reached a maximum at 900 deg. C annealing whereas the S-parameter did not change significantly. It seems that most damages recover at 600 deg. C and thereafter Er ions transform to an optically active state at 900 deg. C.

  7. Experimental Study of a Positron\\\\ Source Using Channeling

    CERN Multimedia

    Gavrykov, V; Kulibaba, V; Baier, V; Beloborodov, K; Bojenok, A; Bukin, A; Burdin, S; Dimova, T; Druzhinin, V; Dubrovin, M; Seredniakov, S; Shary, V; Strakhovenko, V; Keppler, P; Major, J; Bogdanov, A V; Potylitsin, A; Vnoukov, I; Artru, X; Lautesse, P; Poizat, J-C; Remillieux, J

    2002-01-01

    Many simulations have predicted that the yield of positrons, resulting from the interaction of fast electrons in a solid target, increases if the target is a crystal oriented with a major axis parallel to the electron beam. Tests made at Orsay and Tokyo confirmed these expectations. The experiment WA 103 concerns the determination of the main characteristics (emittance, energy spread) of a crystal positron source which could replace advantageously the conventional positron converters foreseen in some linear collider projects. The main element of the set-up is a magnetic spectrometer, using a drift chamber, where the positron trajectories are reconstructed (see Figure 1) A first run has been operated in july 2000 and the first results showed, as expected, a significant enhancement in photon and positron generation along the $$ axis of the tungsten crystal. Indications about a significant increase in the number of soft photons and positrons were also gathered : this point is of importance for the positron colle...

  8. Positron annihilation in germanium in thermal equilibrium at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Moriya, Tsuyoshi; Komuro, Naoyuki; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kawano, Takao; Ikari, Atsushi

    1996-09-01

    Annihilation characteristics of positrons in Ge in thermal equilibrium at high temperature were studied using a monoenergetic positron beam. Precise measurements of Doppler broadening profiles of annihilation radiation were performed in the temperature range between 300 K and 1211 K. The line shape parameters of Doppler broadening profiles were found to be almost constant at 300-600 K. The changes in these parameters were observed to start above 600 K. This was attributed to both the decrease in the fraction of positrons annihilating with core electrons and the lowering of the crystal symmetry around the region detected by positron-electron pairs. This suggests that behaviors of positrons are dominated by some form of positron-lattice coupling in Ge at high temperatures. The temperature dependence of the diffusion length of positrons was also discussed. (author)

  9. Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

    International Nuclear Information System (INIS)

    Donovan, E. M.; James, H.; Bonora, M.; Yarnold, J. R.; Evans, P. M.

    2012-01-01

    Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that

  10. Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Donovan, E. M.; James, H.; Bonora, M.; Yarnold, J. R.; Evans, P. M. [Joint Department of Physics, Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Sutton SM2 5PT (United Kingdom); Physics Department, Ipswich Hospital NHS Foundation Trust, Ipswich IP4 5PD (United Kingdom); Department of Academic Radiotherapy, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton SM2 5PT, United Kingdom and School of Radiotherapy, University of Milan, Milan 20122 (Italy); Department of Academic Radiotherapy, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton SM2 5PT (United Kingdom); Centre for Vision Speech and Signal Processing, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2012-10-15

    Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that

  11. Monte Carlo transport of electrons and positrons through thin foils

    International Nuclear Information System (INIS)

    Legarda, F.; Idoeta, R.

    2000-01-01

    In the different measurements made with electrons traversing matter it becomes useful the knowledge of its transmission through that medium, their paths and their angular distribution through matter so as to process and get information about the traversed medium and to improve and innovate the techniques that employ electrons, as medical applications or materials irradiation. This work presents a simulation of the transport of beams of electrons and positrons through thin foils using an analog Monte Carlo code that simulates in a detailed way every electron movement or interaction in matter. As those particles penetrate thin absorbers it has been assumed that they interact with matter only through elastic scattering, with negligible energy loss. This type of interaction has been described quite precisely because its angular form influences very much the angular distribution of electrons and positrons in matter. With this code it has been calculated the number of particles, with energies between 100 and 3000 keV, that are transmitted through different media of various thicknesses as well as its angular distribution, showing a good agreement with experimental data. The discrepancies are less than 5% for thicknesses lower than about 30% of the corresponding range in the tested material. As elastic scattering is very anisotropic, angular distributions resemble a collimated incident beam for very thin foils becoming slowly more isotropic when absorber thickness is increased. (author)

  12. On the Possibility of Accelerating Positron on an Electron Wake at SABER

    International Nuclear Information System (INIS)

    Ischebeck, R.; Joshi, C.; Katsouleas, T.C.; Muggli, P.; Wang, X.

    2008-01-01

    A new approach for positron acceleration in non-linear plasma wakefields driven by electron beams is presented. Positrons can be produced by colliding an electron beam with a thin foil target embedded in the plasma. Integration of positron production and acceleration in one stage is realized by a single relativistic, intense electron beam. Simulations with the parameters of the proposed SABER facility [1] at SLAC suggest that this concept could be tested there

  13. Transmission positron microscopes

    International Nuclear Information System (INIS)

    Doyama, Masao; Kogure, Yoshiaki; Inoue, Miyoshi; Kurihara, Toshikazu; Yoshiie, Toshimasa; Oshima, Ryuichiro; Matsuya, Miyuki

    2006-01-01

    Immediate and near-future plans for transmission positron microscopes being built at KEK, Tsukuba, Japan, are described. The characteristic feature of this project is remolding a commercial electron microscope to a positron microscope. A point source of electrons kept at a negative high voltage is changed to a point source of positrons kept at a high positive voltage. Positional resolution of transmission microscopes should be theoretically the same as electron microscopes. Positron microscopes utilizing trapping of positrons have always positional ambiguity due to the diffusion of positrons

  14. Development of an undulator-based polarized positron source for ...

    Indian Academy of Sciences (India)

    at KEK [1a], Compton backscattering is used [2], the E166 experiment uses a helical undulator to produce polarized photons. An undulator-based positron source for the ILC has been proposed in [3,4]. The proposed scheme for an ILC positron source is illustrated in figure 1. In this scheme, a 150 GeV electron beam passes.

  15. Theory, development, and applications of the scanning positron microbeam and positron reemission microscope

    International Nuclear Information System (INIS)

    Brandes, G.R.

    1990-01-01

    The theory, design, development, and applications of two new imaging instruments, the scanning positron microbeam (SPM) and positron reemission microscope (PRM), are discussed. The SPM consists of a sectored lens which focuses and rasters the positrons from the beam across the sample. The results of rastering the 10μm x 50μm beam across a test grid demonstrate the SPM's ability to scan a 500μm diameter region and to resolve features with ∼ 5μm resolution. The SPM was used to examine the location of defects in a Si-on-SiO 2 sample. Possible applications to three dimensional defect spectroscopy and the observation of small samples are considered. In the PRM, the positrons from the brightness-enhanced beam are focused at 5keV to an 8/Am diameter spot (FWHM) onto a thin metal single crystal. An image of the opposing side of the film is formed by accelerating and focusing the reemitted thermalized positrons with a cathode lens objective and a projector lens. The final image (real) is a record of the thermal positron emission intensity versus position. Images of surface and subsurface defect structures, taken at magnifications up to 4400x and with a resolution up to 80nm, are presented and discussed. The ultimate resolution capabilities and possible applications of the PRM are examined. The implantation and diffusion process of positrons was studied with the PRM by examining the positron emission profile of 3-9keV positrons implanted into a 2200 angstrom thick Ni single crystal

  16. Molecular-beam epitaxy growth and structural characterization of semiconductor-ferromagnet heterostructures by grazing incidence X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Satapathy, D.K.

    2005-12-19

    The present work is devoted to the growth of the ferromagnetic metal MnAs on the semiconductor GaAs by molecular-beam epitaxy (MBE). The MnAs thin films are deposited on GaAs by molecular-beam epitaxy (MBE). Grazing incidence diffraction (GID) and reflection high-energy electron diffraction (RHEED) are used in situ to investigate the nucleation, evolution of strain, morphology and interfacial structure during the MBE growth. Four stages of the nucleation process during growth of MnAs on GaAs(001) are revealed by RHEED azimuthal scans. GID shows that further growth of MnAs films proceed via the formation of relaxed islands at a nominal thickness of 2.5 ML which increase in size and finally coalesce to form a continuous film. Early on, an ordered array of misfit dislocations forms at the interface releasing the misfit strain even before complete coalescence occurs. The fascinating complex nucleation process of MnAs on GaAs(0 0 1) contains elements of both Volmer-Weber and Stranski-Krastanov growth. A nonuniform strain amounting to 0.66%, along the [1 -1 0] direction and 0.54%, along the [1 1 0] direction is demonstrated from x-ray line profile analysis. A high correlation between the defects is found along the GaAs[1 1 0] direction. An extremely periodic array of misfit dislocations with a period of 4.95{+-}0.05 nm is formed at the interface along the [1 1 0] direction which releases the 7.5% of misfit. The inhomogeneous strain due to the periodic dislocations is confined at the interface within a layer of 1.6 nm thickness. The misfit along the [1 -1 0] direction is released by the formation of a coincidence site lattice. (orig.)

  17. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  18. beta sup + -gamma coincidence positron lifetime spectrometer with positron energy selection by electromagnetic lens

    CERN Document Server

    Chalermkarnnon, P; Araki, H; Shirai, Y; Shishido, I

    2002-01-01

    A beta sup + -gamma coincidence positron lifetime spectrometer equipped with two electromagnetic lenses was constructed. The electromagnetic lens was used to have energy-selected positron beam. It accomplished a time resolution of 385 ps (FWHM) for the total system with a Pilot U plastic scintillator. By using a silicon avalanche diode instead of Pilot U plastic scintillator to initiate start timing signals, the time resolution was improved to 345 ps (FWHM). With this method, in-situ positron lifetime measurements at high temperatures or under high stresses can be attained easily. (author)

  19. Electron-Positron Accumulator (EPA)

    CERN Multimedia

    Photographic Service

    1986-01-01

    After acceleration in the low-current linac LIL-W, the electrons and positrons are accumulated in EPA to obtain a sufficient intensity and a suitable time-structure, before being passed on to the PS for further acceleration to 3.5 GeV. Electrons circulate from right to left, positrons in the other direction. Dipole bending magnets are red, focusing quadrupoles blue, sextupoles for chromaticity-control orange. The vertical tube at the left of the picture belongs to an optical transport system carrying the synchrotron radiation to detectors for beam size measurement. Construction of EPA was completed in spring 1986. LIL-W and EPA were conceived for an energy of 600 MeV, but operation was limited to 500 MeV.

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  1. An Undulator based Polarized Positron Source for CLIC

    CERN Document Server

    Liu, Wanming; Rinolfi, Louis; Sheppard, John

    2010-01-01

    A viable positron source scheme is proposed that uses circularly polarized gamma rays generated from the main 250 GeV electron beam. The beam passes through a helical superconducting undulator with a magnetic field of ~ 1 Tesla and a period of 1.15 cm. The gamma-rays produced in the undulator in the energy range between ~ 3 MeV – 100 MeV will be directed to a titanium target and produce polarized positrons. The positrons are then captured, accelerated and transported to a Pre-Damping Ring (PDR). Detailed parameter studies of this scheme including positron yield, and undulator parameter dependence are presented. Effects on the 250 GeV CLIC main beam, including emittance growth and energy loss from the beam passing through the undulator are also discussed

  2. Fragmentation and direct transfer reactions for 40Ar incident beam on 27Al target at 1760 MeV

    International Nuclear Information System (INIS)

    Cisse, Ousmane

    1985-01-01

    Peripheral collision studies performed with 40 Ar projectiles at 44 MeV/A and 27 Al target show that both fragmentation and transfer reactions can be discerned in this type of interaction. The experimental observation of fragments with masses charges and velocities close to those of the incident beam are the signature of transfer reactions and a detailed analysis of the energy spectra of such fragments has been carried out and interpreted in terms of a direct diffraction transfer model. On the other hand, for large mass transfer reactions, abrasion is the suitable mechanism. Inclusive fragment measurement together with the appropriate residual nuclei-fragment coincidence results then provides experimental data in good agreement with the theoretical predictions obtained from a participant spectator model. These investigations also indicate that the separation energies of the participant from the spectator nucleus, at least within the framework of the above model, can be interpreted in terms of a friction force which becomes more efficient as the projectile energy decreases. (author) [fr

  3. 3D numerical thermal stress analysis of the high power target for the SLC Positron Source

    International Nuclear Information System (INIS)

    Reuter, E.M.; Hodgson, J.A.

    1991-05-01

    The volumetrically nonuniform power deposition of the incident 33 GeV electron beam in the SLC Positron Source Target is hypothesized to be the most likely cause target failure. The resultant pulsed temperature distributions are known to generate complicated stress fields with no known closed-form analytical solution. 3D finite element analyses of these temperature distributions and associated thermal stress fields in the new High Power Target are described here. Operational guidelines based on the results of these analyses combined with assumptions made about the fatigue characteristics of the exotic target material are proposed. 6 refs., 4 figs

  4. Using of slow positrons in various investigations - state of the art and perspectives

    CERN Document Server

    Belyaev, V N

    2000-01-01

    Slow positrons have become a unique probe in research of electronic structure of matter, in data acquisition on Fermi surface in metals and alloys, in studying of formation processes of structural and radiation defects in metals, semiconductors, polymers and nanocrystalline structures. First positron microscopes, PAES-spectrometers, positron ionization mass spectrometers and positron tomographs have been already created. In this paper results obtained by positron annihilation method in different research fields and possibilities of future progress in obtaining of high-intensity, high-brightness slow positron beams of variable energy are briefly discussed.

  5. Defects in Czochralski-grown silicon crystals investigated by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Ikari, Atsushi; Kawakami, Kazuto; Haga, Hiroyo [Nippon Steel Corp., Sagamihara, Kanagawa (Japan). Electronics Research Labs.; Uedono, Akira; Wei, Long; Kawano, Takao; Tanigawa, Shoichiro

    1994-10-01

    Positron lifetime and Doppler broadening experiments were performed on Czochralski-grown silicon crystals. A monoenergetic positron beam was also used to measure the diffusion length of positrons in the wafer. From the measurements, it was observed that the value of diffusion length of positrons decreased at the region where microdefects were formed during the crystal growth process. It was also found that the line shape parameter S decreased and the lifetime of positrons increased at the region. These results can be attributed to the annihilation of positrons trapped by vacancy oxygen complexes which are formed in association with the microdefects. (author).

  6. Positron scattering from vinyl acetate

    International Nuclear Information System (INIS)

    Chiari, L; Brunger, M J; Zecca, A; Blanco, F; García, G

    2014-01-01

    Using a Beer–Lambert attenuation approach, we report measured total cross sections (TCSs) for positron scattering from vinyl acetate (C 4 H 6 O 2 ) in the incident positron energy range 0.15–50 eV. In addition, we also report an independent atom model with screening corrected additivity rule computation results for the TCSs, differential and integral elastic cross sections, the positronium formation cross section and inelastic integral cross sections. The energy range of these calculations is 1–1000 eV. While there is a reasonable qualitative correspondence between measurement and calculation for the TCSs, in terms of the energy dependence of those cross sections, the theory was found to be a factor of ∼2 larger in magnitude at the lower energies, even after the measured data were corrected for the forward angle scattering effect. (paper)

  7. Development of a Positron Source for JLab at the IAC

    Energy Technology Data Exchange (ETDEWEB)

    Forest, Tony [Idaho State Univ., Pocatello, ID (United States)

    2013-10-12

    We report on the research performed towards the development of a positron sour for Jefferson Lab's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, VA. The first year of work was used to benchmark the predictions of our current simulation with positron production efficiency measurements at the IAC. The second year used the benchmarked simulation to design a beam line configuration which optimized positron production efficiency while minimizing radioactive waste as well as design and construct a positron converter target. The final year quantified the performance of the positron source. This joint research and development project brought together the experiences of both electron accelerator facilities. Our intention is to use the project as a spring board towards developing a program of accelerator based research and education which will train students to meet the needs of both facilities as well as provide a pool of trained scientists.

  8. A multiwire secondary emission profile monitor for small emittance beams

    International Nuclear Information System (INIS)

    Chehab, R.; Bonnard, J.; Humbert, G.; Leblond, B.; Saury, J.L.

    1985-01-01

    A secondary emission monitor using two multiwire grids separated by a positively biased collector has been constructed and tested with a 1 GeV electron beam at the Orsay Linac. The monitor installed just before the electron-positron converter has 8 gold-plated-tungsten wires of 0.1 mm diameter equally spaced 0.2 mm apart in each plane. Each wire is connected with an integrator using a low-bias current operational amplifier. The wire planes and the collector are moved into the beam by a stepping motor : that allows beam-position verification. We measured narrow profiles for 1 Amp peak current pulses of 30 nanoseconds width. Profiles are displayed on a scope and allow emittance determination by the three gradient method. Such a monitor is very useful to control the electron beam position and dimensions on the converter, because the positron source dimensions are rather bigger than those of the incident beam and the geometrical acceptance of the positron Linac is limited

  9. Long range heliostat target using array of normal incidence pyranometers to evaluate a beam of solar radiation

    Science.gov (United States)

    Ghanbari, Cheryl M; Ho, Clifford K; Kolb, Gregory J

    2014-03-04

    Various technologies described herein pertain to evaluating a beam reflected by a heliostat. A portable target that has an array of sensors mounted thereupon is configured to capture the beam reflected by the heliostat. The sensors in the array output measured values indicative of a characteristic of the beam reflected by the heliostat. Moreover, a computing device can generate and output data corresponding to the beam reflected by the heliostat based on the measured values indicative of the characteristic of the beam received from the sensors in the array.

  10. Feasibility and conceptual design of a C.W. positron source at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Golge, Serkan [Old Dominion Univ., Norfolk, VA (United States)

    2010-08-01

    A feasibility study of a CW positron source for the 12 GeV upgrade at Jefferson Lab (JLAB) is provided. The proposed ≥ 100 nA Continuous Wave (CW) positron source at JLAB has several unique and challenging characteristics: high current incident electron beam at 126 MeV with a high beam power (up to a MW); CW e- beam and CW e+ production. The multiple scattering is a dominant process when creating e+ in a target, which results a large phase space area of the emitted positrons. An admittance study was done at CEBAF to find the maximum phase space area, which is tolerated in the machine. The measured geometrical transverse admittance (A) were Ax =10 and Ay = 5 mm∙mrad at the injector. Energy spread measurement was also done at the ARC1. The fractional spread limit in the ARC1 was measured as δ = 3×10-3 at 653 MeV. By using the optimized results and the CEBAF parameters, three positron injector configurations are proposed; Combined Function Magnet, Two-Dipole and Microtron Dipole configurations. With the assumptions made, by using 126 MeV Ⓧ10 mA e- beam impinging on a 2 mm W target with a 100 μm spot size, we can get up to 3 μA useful e+ current at the North Linac connection. One of the biggest challenges is the target design, which the deposited power is about 60 kW. ILC designs project power deposition up to 13 kW, which would allow the creation of a e+ beam of up to 650 nA otherwise. The results of analytic and monte carlo simulations of the positron production, capture and acceleration are presented. For the target design, a review is presented of solutions for the high power production target. Portions of this dissertation work have been published in two conference proceedings.

  11. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  12. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  13. Local vacancies in optical modulation polymers studied by positron annihilation lifetime measurements

    International Nuclear Information System (INIS)

    Shimazu, Akira

    2009-01-01

    The ability of a slow positron beam to prove vacancies at the surface and in bulk regions of optical modulation polymers was demonstrated. A slow positron beam system was found to be a powerful tool to study the change in the microstructure driven by photopolymerization of novel optical modulation polymers. (author)

  14. Observation of diffraction effects in positron channeling

    International Nuclear Information System (INIS)

    Palathingal, J.C.; Peng, J.P.; Lynn, K.G.; Wu, X.Y.; Schultz, P.J.

    1994-01-01

    An experimental investigation of positron channeling was made with a high-angular resolution apparatus, employing positrons of kinetic energy 1 MeV, derived from the Brookhaven National Laboratory Dynamitron. The pattern of transmission through a Si (100) single crystal of thickness 0.245 μm was investigated for a number of major planes. The authors have observed for the first time, in excellent detail, the fine structure of the channeling pattern expected to arise from the particle diffraction effects, theoretically explainable in terms of the quantum-mechanical many-beam calculations

  15. High energy positron imaging

    International Nuclear Information System (INIS)

    Chen Shengzu

    2003-01-01

    The technique of High Energy Positron Imaging (HEPI) is the new development and extension of Positron Emission Tomography (PET). It consists of High Energy Collimation Imaging (HECI), Dual Head Coincidence Detection Imaging (DHCDI) and Positron Emission Tomography (PET). We describe the history of the development and the basic principle of the imaging methods of HEPI in details in this paper. Finally, the new technique of the imaging fusion, which combined the anatomical image and the functional image together are also introduced briefly

  16. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  17. Positrons and positronium

    International Nuclear Information System (INIS)

    Jean, Y.C.; Lambrecht, R.M.

    1988-01-01

    This bibliography includes articles, proceedings, abstracts, reports and patents published between 1930 and 1984 on the subject of positrons, positron annihilation and positronium. The subject covers experimental and theoretical results in the areas of physics and chemistry of low and intermediate energy (< 0.6 MeV) positrons and positronium. The topics of interest are: fundamental properties, interactions with matter, nuclear technology, the history and philosophy of antimatter, the theory of the universe, and the applications of positrons in the chemical, physical, and biomedical sciences

  18. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  19. Formation of a high intensity low energy positron string

    International Nuclear Information System (INIS)

    Donets, E.D.; Donets, E.E.; Syresin, E.M.; Itahashi, T.; Dubinov, A.E.

    2004-01-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5x10 9 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production

  20. Influence of Polarization of the Incident Beam on Integrated Intensities in X-Ray Energy-Dispersive Diffractometry

    DEFF Research Database (Denmark)

    Olsen, J. Staun; Buras, B.; Jensen, T.

    1978-01-01

    Polarization measurements of the primary X-ray beam produced by thick copper and tungsten anodes are reported and formulas derived for integrated intensities of Bragg reflections in energy-dispersive diffractometry with the polarization of the primary beam taken into account. It was found...

  1. Evaluation by dental cone-beam computed tomography of the incidence and sites of branches of the inferior dental canal that supply mandibular third molars.

    Science.gov (United States)

    Ogawa, A; Fukuta, Y; Nakasato, H; Nakasato, S

    2016-12-01

    Our aim was to assess the incidence and anatomical site of branches of the inferior dental canal that supply mandibular third molars using dental cone-beam computed tomography (CT). We evaluated the incidence and diameter of branches of the inferior dental canal using 272 cone-beam CT mandibular scans from 172 patients referred for imaging before the extraction of impacted mandibular third molars. We found three typical branching patterns from the inferior dental canal in the third molar region: the retromolar canal (in the retromolar triangle), the dental canal (that courses directly beneath the socket of the third molar), and the accessory canal (that courses through the socket and leads from the inferior dental canal to a bony ridge). The incidences of retromolar, dental, and accessory canals were 75 (28%), 223 (82%), and 21 (8%), respectively, with mean diameters of 0.9 (0.4), 0.7 (0.5), and 1.1 (0.4) mm, respectively. Operative injury to the neurovascular contents within the branches of the inferior dental canal can lead to excessive bleeding and postoperative paraesthesia, so identification of its branches on preoperative cone-beam CT images may prove useful during extraction of impacted mandibular third molars or when harvesting bone blocks from the region of mandibular third molars. We also describe two cases of branches detected on panoramic and cone-beam CT images that prompted this research. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  3. Positron annihilation microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Canter, K.F. [Brandeis Univ., Waltham, MA (United States)

    1997-03-01

    Advances in positron annihilation microprobe development are reviewed. The present resolution achievable is 3 {mu}m. The ultimate resolution is expected to be 0.1 {mu}m which will enable the positron microprobe to be a valuable tool in the development of 0.1 {mu}m scale electronic devices in the future. (author)

  4. SPM: Scanning positron microscope

    Directory of Open Access Journals (Sweden)

    Marcel Dickmann

    2015-08-01

    Full Text Available The Munich scanning positron microscope, operated by the Universität der Bundeswehr München and the Technische Universität München, located at NEPOMUC, permits positron lifetime measurements with a lateral resolution in the µm range and within an energy range of 1 – 20 keV.

  5. Positrons in ionic crystals

    International Nuclear Information System (INIS)

    Pareja, R.

    1988-01-01

    Positron annihilation experiments in ionic crystals are reviewed and their results are arranged. A discussion about the positron states in these materials is made in the light of these results and the different proposed models. The positronium in alkali halides is specially considered. (Author)

  6. Incident neutron spectra on the first wall and their application to energetic ion diagnostics in beam-injected deuterium-tritium tokamak plasmas

    Science.gov (United States)

    Sugiyama, S.; Matsuura, H.; Uchiyama, D.

    2017-09-01

    A diagnostic method for small non-Maxwellian tails in fuel-ion velocity distribution functions is proposed; this method uses the anisotropy of neutron emissions, and it is based on the numerical analysis of the incident fast neutron spectrum on the first wall of a fusion device. Neutron energy spectra are investigated for each incident position along the first wall and each angle of incidence assuming an ITER-like deuterium-tritium plasma; it is heated by tangential-neutral-beam injection. Evaluating the incident neutron spectra at all wall positions and angles of incidence enables the selective measurement of non-Gaussian components in the neutron emission spectrum for energetic ion diagnostics; in addition, the optimal detector position and orientation can be determined. At the optimal detector position and orientation, the ratio of non-Gaussian components to the Gaussian peak can be two orders of magnitude greater than the ratio in the neutron emission spectrum. This result can improve the accuracy of energetic ion diagnostics in plasmas when small, anisotropic non-Maxwellian tails are formed in fuel ion velocity distribution functions. We focus on the non-Gaussian components greater than 14 MeV, where the effect of the background noise (i.e., slowing-down neutrons by scattering throughout the machine structure) can be ignored.

  7. Positron astrophysics and areas of relation to low-energy positron physics

    International Nuclear Information System (INIS)

    Guessoum, N.

    2014-01-01

    I briefly review our general knowledge of positron astrophysics, focusing mostly on the theoretical and modelling aspects. The experimental/observational aspects of the topic have recently been reviewed elsewhere [E. Churazov et al., Mon. Nat. R. Astron. Soc. 411, 1727 (2011); N. Prantazos et al., Rev. Mod. Phys. 83, 1001 (2011)]. In particular, I highlight the interactions and cross sections of the reactions that the positrons undergo in various cosmic media. Indeed, these must be of high interest to both the positron astrophysics community and the low-energy positron physics community in trying to find common areas of potential collaboration for the future or areas of research that will help the astrophysics community make further progress on the problem. The processes undergone by positrons from the moments of their birth to their annihilation (in the interstellar medium or other locations) are thus examined. The physics of the positron interactions with gases and solids (dust grains) and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation take place, are briefly reviewed. An explanation is given about how all the relevant physical information is taken into account in order to calculate annihilation rates and spectra of the 511 keV emission in the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. In particular, an attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of low-energy positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place

  8. Quantum resonances in reflection of relativistic electrons and positrons

    International Nuclear Information System (INIS)

    Eykhorn, Yu.L.; Korotchenko, K.B.; Pivovarov, Yu.L.; Takabayashi, Y.

    2015-01-01

    Calculations based on the use of realistic potential of the system of crystallographic planes confirm earlier results on existence of resonances in reflection of relativistic electrons and positrons by the crystal surface, if the crystallographic planes are parallel to the surface.The physical reason of predicted phenomena, similar to the band structure of transverse energy levels, is connected with the Bloch form of the wave functions of electrons (positrons) near the crystallographic planes, which appears both in the case of planar channeling of relativistic electrons (positrons) and in reflection by a crystal surface. Calculations show that positions of maxima in reflection of relativistic electrons and positrons by crystal surface specifically depend on the angle of incidence with respect to the crystal surface and relativistic factor of electrons/positrons. These maxima form the Darwin tables similar to that in ultra-cold neutron diffraction

  9. DHCAL with Minimal Absorber: Measurements with Positrons

    CERN Document Server

    Freund, B; Repond, J.; Schlereth, J.; Xia, L.; Dotti, A.; Grefe, C.; Ivantchenko, V.; Antequera, J.Berenguer; Calvo Alamillo, E.; Fouz, M.C.; Marin, J.; Puerta-Pelayo, J.; Verdugo, A.; Brianne, E.; Ebrahimi, A.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.; Hermberg, B.; Irles, A.; Krivan, F.; Krüger, K.; Kvasnicka, J.; Lu, S.; Lutz, B.; Morgunov, V.; Provenza, A.; Reinecke, M.; Sefkow, F.; Schuwalow, S.; Tran, H.L.; Garutti, E.; Laurien, S.; Matysek, M.; Ramilli, M.; Schroeder, S.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kovalcuk, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; van Doren, B.; Wilson, G.W.; Kawagoe, K.; Hirai, H.; Sudo, Y.; Suehara, T.; Sumida, H.; Takada, S.; Tomita, T.; Yoshioka, T.; Bilokin, S.; Bonis, J.; Cornebise, P.; Pöschl, R.; Richard, F.; Thiebault, A.; Zerwas, D.; Hostachy, J.Y.; Morin, L.; Besson, D.; Chadeeva, M.; Danilov, M.; Markin, O.; Popova, E.; Gabriel, M.; Goecke, P.; Kiesling, C.; Kolk, N.van der; Simon, F.; Szalay, M.; Corriveau, F.; Blazey, G.C.; Dyshkant, A.; Francis, K.; Zutshi, V.; Kotera, K.; Ono, H.; Takeshita, T.; Ieki, S.; Kamiya, Y.; Ootani, W.; Shibata, N.; Jeans, D.; Komamiya, S.; Nakanishi, H.

    2016-01-01

    In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

  10. DHCAL with minimal absorber: measurements with positrons

    International Nuclear Information System (INIS)

    Freund, B.; Neubüser, C.; Repond, J.; Schlereth, J.; Xia, L.; Dotti, A.; Grefe, C.; Ivantchenko, V.; Antequera, J. Berenguer; Alamillo, E. Calvo; Fouz, M.-C.; Marin, J.; Puerta-Pelayo, J.; Verdugo, A.; Brianne, E.; Ebrahimi, A.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.

    2016-01-01

    In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.

  11. Combined phenomena of beam-beam and beam-electron cloud interactionsin circular e^{+}e^{-} colliders

    Directory of Open Access Journals (Sweden)

    Kazuhito Ohmi

    2002-10-01

    Full Text Available An electron cloud causes various effects in high intensity positron storage rings. The positron beam and the electron cloud can be considered a typical two-stream system with a certain plasma frequency. Beam-beam interaction is another important effect for high luminosity circular colliders. Colliding two beams can be considered as a two-stream system with another plasma frequency. We study the combined phenomena of the beam-electron cloud and beam-beam interactions from a viewpoint of two complex two-stream effects with two plasma frequencies.

  12. Single-beam integrating sphere spectrophotometer for reflectance and transmittance measurements versus angle of incidence in the solar wavelength range on diffuse and specular samples

    Science.gov (United States)

    Nostell, Per; Roos, Arne; Rönnow, Daniel

    1999-05-01

    A multipurpose instrument for the measurement of reflectance and transmittance versus angle of incidence for both specular and diffuse samples in the solar wavelength range has been constructed and evaluated. The instrument operates in the single-beam mode and uses a common light source for three experimental setups. Two integrating spheres, 20 cm in diameter, are used for diffuse transmittance and reflectance measurements. The transmittance sphere can be turned around an axis through the sample to vary the angle of incidence. The reflectance sphere uses a center mounted sample and a special feature is the position of the detector, which is mounted on the sample holder at the center of the sphere. This way the detector always sees the same part of the sphere wall and no light can reach the detector directly from the sample. The third setup is an absolute instrument for specular samples. It uses a small averaging sphere as a detector. The detector is mounted on an arm which rotates around the center of the sample, and it can thus pick up both the reflected and transmitted beams including all multiply reflected components. The averaging sphere detector is insensitive to small side shifts of the detected beams and no multiple reflections between detector and optical system occur. In this report a number of calibration procedures are presented for the three experimental setups and models for the calculation of correct transmittance and reflectance values from measured data are presented. It is shown that for integrating sphere measurements, the geometry of the sphere and the diffusivity of the sample as well as the sphere wall reflectance and port losses are important factors that influence the result. For the center mounted configuration these factors are particularly important and special emphasis is given to the evaluation of the reflectance sphere model. All three instrument setups are calibrated using certified reference materials and nonscattering mirrors and

  13. Conceptual design of a high-intensity positron source for the Advanced Neutron Source

    International Nuclear Information System (INIS)

    Hulett, L.D.; Eberle, C.C.

    1994-12-01

    The Advanced Neutron Source (ANS) is a planned new basic and applied research facility based on a powerful steady-state research reactor that provides neutrons for measurements and experiments in the fields of materials science and engineering, biology, chemistry, materials analysis, and nuclear science. The useful neutron flux will be at least five times more than is available in the world's best existing reactor facility. Construction of the ANS provides a unique opportunity to build a positron spectroscopy facility (PSF) with very-high-intensity beams based on the radioactive decay of a positron-generating isotope. The estimated maximum beam current is 1000 to 5000 times higher than that available at the world's best existing positron research facility. Such an improvement in beam capability, coupled with complementary detectors, will reduce experiment durations from months to less than one hour while simultaneously improving output resolution. This facility will remove the existing barriers to the routine use of positron-based analytical techniques and will be a giant step toward realization of the full potential of the application of positron spectroscopy to materials science. The ANS PSF is based on a batch cycle process using 64 Cu isotope as the positron emitter and represents the status of the design at the end of last year. Recent work not included in this report, has led to a proposal for placing the laboratory space for the positron experiments outside the ANS containment; however, the design of the positron source is not changed by that relocation. Hydraulic and pneumatic flight tubes transport the source material between the reactor and the positron source where the beam is generated and conditioned. The beam is then transported through a beam pipe to one of several available detectors. The design presented here includes all systems necessary to support the positron source, but the beam pipe and detectors have not been addressed yet

  14. Incidence of primary hypothyroidism in patients exposed to therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland

    Directory of Open Access Journals (Sweden)

    B A Laway

    2012-01-01

    Full Text Available Introduction: Hypothyroidism is a known consequence of external-beam radiotherapy to the neck encompassing a part or whole of the thyroid gland. In this non-randomized prospective study, we have tried to evaluate the response of the thyroid gland to radiation by assessing thyroid function before irradiation and at regular intervals after irradiation. Aims and Objectives: The aim of this study were to assess in the cancer patients, who were exposed to the therapeutic external beam radiation, where radiation portals include a part or whole of the thyroid gland: the incidence of primary hypothyroidism, the time required to become hypothyroid, any relation between the total dose for the development of hypothyroidism, and whether there are any patient or treatment-related factors that are predictive for the development of hypothyroidism, including the use of concurrent chemotherapy. Materials and Methods: This non-randomized, prospective study was conducted for a period of 2 years in which thyroid function was assessed in 59 patients (cases of head and neck cancer, breast cancer, lymphoma patients and other malignancies, who had received radiotherapy to the neck region. 59 euthyroid healthy patients (controls were also taken, who had not received the neck irradiation. These patients/controls were assessed periodically for 2 years. Results: The incidence of hypothyroidism after external beam radiation therapy (EBRT to neck where radiation portals include part or whole of the thyroid gland was 16.94%, seven cases had subclinical hypothyroidism (11.86% and three cases had clinical hypothyroidism (5.08%. Mean time for development of hypothyroidism was 4.5 months. There was no effect of age, gender, primary tumor site, radiation dose and chemotherapy, whether neoadjuvant or concurrent with the development of hypothyroidism. Conclusion: In summary, we found that thyroid dysfunction is a prevalent, yet easily treatable source of morbidity in patients

  15. Use of External Beam Radiotherapy Is Associated With Reduced Incidence of Second Primary Head and Neck Cancer: A SEER Database Analysis

    International Nuclear Information System (INIS)

    Rusthoven, Kyle; Chen Changhu; Raben, David; Kavanagh, Brian

    2008-01-01

    Purpose: Patients with head and neck cancer have a significant risk of developing a second primary cancer of the head and neck. We hypothesized that treatment with external beam radiotherapy (RT) might reduce this risk, because RT can eradicate occult foci of second head and neck cancer (HNCA). Methods and Materials: The data of patients with Surveillance, Epidemiology, and End Results Historic Stage A localized squamous cell carcinoma of the oral cavity, larynx, and pharynx were queried using the Surveillance, Epidemiology, and End Results database. For patients treated with or without RT, the incidence of second HNCA was determined and compared using the log-rank method. Cox proportional hazards analysis was performed for each site, evaluating the influence of covariates on the risk of second HNCA. Results: Between 1973 and 1997, 27,985 patients were entered with localized HNCA. Of these patients, 44% had received RT and 56% had not. The 15-year incidence of second HNCA was 7.7% with RT vs. 10.5% without RT (hazard ratio 0.71, p <0.0001). The effect of RT was more profound in patients diagnosed between 1988 and 1997 (hazard ratio 0.53, p <0.0001) and those with pharynx primaries (hazard ratio 0.47, p <0.0001). On multivariate analysis, RT was associated with a reduced risk of second HNCA for pharynx (p <0.0001) and larynx (p = 0.04) tumors. For oral cavity primaries, RT was associated with an increased risk of second HNCA in patients treated before 1988 (p <0.001), but had no influence on patients treated between 1988 and 1997 (p = 0.91). Conclusion: For localized HNCA, RT is associated with a reduced incidence of second HNCA. These observations are consistent with the eradication of microscopic foci of second HNCA with external beam RT

  16. Observations of discrete energy loss effects in spectra of positrons reflected from solid surfaces

    International Nuclear Information System (INIS)

    Dale, J.M.; Hulett, L.D.; Pendyala, S.

    1980-01-01

    Surfaces of tungsten and silicon have been bombarded with monoenergetic beams of positrons and electrons. Spectra of reflected particles show energy loss tails with discrete peaks at kinetic energies about 15 eV lower than that of the elastic peaks. In the higher energy loss range for tungsten, positron spectra show fine structure that is not apparent in the electron spectra. This suggests that the positrons are losing energy through mechanisms different from that of the electrons

  17. L3: Decay of Z0 to positron-electron pair

    CERN Multimedia

    1991-01-01

    This track is an example of real data collected from the L3 detector on the Large Electron-Positron (LEP) collider at CERN, which ran between 1989 and 2000. An electron-positron pair is captured within the L3 detector, which originated from the decay of a Z0, that was in turn produced through the annihilation of an electron and positron within the LEP beams.

  18. Polarized positron sources for the future linear colliders

    International Nuclear Information System (INIS)

    Chaikovska, I.

    2012-01-01

    This thesis introduces the polarized positron source as one of the key element of the future Linear Collider (LC). In this context, the different schemes of the polarized positron source are described highlighting the main issues in this technology. In particular, the main focus is on the Compton based positron source adopted by the CLIC as a preferred option for the future positron source upgrade. In this case, the circularly polarized high energy gamma rays resulting from Compton scattering are directed to a production target where an electromagnetic cascade gives rise to the production of positrons by e + -e - pair conversion. To increase the efficiency of the gamma ray production stage, a multiple collision point line integrated in energy recovery linac is proposed. The simulations of the positron production, capture and primary acceleration allow to estimate the positron production efficiency and provide a simple parametrization of the Compton based polarized positron source in the view of the future LC requirements. The storage ring based Compton source option, so-called Compton ring, is also described. The main constraint of this scheme is given by the beam dynamics resulting in the large energy spread and increased bunch length affecting the gamma ray production rate. An original theoretical contribution is shown to calculate the energy spread induced by Compton scattering. Moreover, an experiment to test the gamma ray production by Compton scattering using a state-of-art laser system developed at LAL has been conducted in the framework of the 'Mighty Laser' project at the ATF, KEK. The experimental layout as well as the main results obtained are discussed in details. The studies carried out in this thesis show that the polarized positron source based on Compton scattering is a promising candidate for the future LC polarized positron source. (author)

  19. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  20. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  1. 50 years of positrons

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This year marks the 50th anniversary of one of the major landmarks of modern physics - the discovery of the positron, the antimatter counterpart of the electron. This provided the first evidence for antimatter, and it was also unprecedented for the existence of a new particle to have been predicted by theory. The positron and the concepts behind it were to radically change our picture of Nature. It led to the rapid advancement or our understanding, culminating some fifteen years later with the formulation of quantum electrodynamics as we now know it. (orig./HSI).

  2. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  3. Characterization of ion beam sputtered deposited W/Si multilayers by grazing incidence x-ray diffraction and x-ray reflectivity technique

    Science.gov (United States)

    Dhawan, Rajnish; Rai, Sanjay

    2016-05-01

    W/Si multilayers four samples have been deposited on silicon substrate using ion beam sputtering system. Thickness of tungsten (W) varies from around 10 Å to 40 Å while the silicon (Si) thickness remains constant at around 30 Å in multilayers [W-Si]x4. The samples have been characterized by grazing incidence X-ray diffraction (GIXRD) and X-ray reflectivity technique (XRR). GIXRD study shows the crystalline behaviour of W/Si multilayer by varying W thickness and it is found that above 20 Å the W film transform from amorphous to crystalline phase and X-ray reflectivity data shows that the roughnesses of W increases on increasing the W thicknesses in W/Si multilayers.

  4. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  5. Study of Hadronic Jets Produced by Charged Pion and Proton Beams Incident on Hydrogen and Aluminum Targets

    Energy Technology Data Exchange (ETDEWEB)

    Yung, Kar Woo [California Inst. of Technology (CalTech), Pasadena, CA (United States)

    1979-09-19

    High transverse momentum ($P_T$) particles are thought to reflect the underlying parton (quark or gluon) mechanisms of hadron interactions. A particularly simple model by Feynman, Field and Fox (or FFF>, involves hard scattering of a pair of partons via gluon exchange (Quantum Chromodynamics or GCD) with subsequent fragmentation or the partons into hadrons. We present results from an experiment (E260 at Fermilab) on the production of Jets (groups of particles) and single charged particles, at both low and high $P_T$, in 200 Gev interactions. The experiment used a calorimeter triggered multiparticle spectrometer. Results are presented on the comparisons of cross sections and associated charged particle distributions for pion and proton beams and aluminium and hydrogen targets.

  6. Development of positron annihilation spectroscopy to test accelerated weathering of protective polymer coatings

    CERN Document Server

    Zhang, R; Chen, H M; Mallon, P; Sandreczki, T C; Richardson, J R; Jean, Y C; Nielsen, B; Suzuki, R; Ohdaira, T

    2000-01-01

    A variable mono-energetic positron beam with a computer-controlled system has recently been constructed at the University of Missouri-Kansas City for weathering studies of polymeric coatings. The beam is designed to measure the S-parameter from Doppler-broadening energy spectra and the sub-nanometer defect properties from positron annihilation lifetimes (PAL). Significant variations of S-parameter and ortho-positronium intensity in coatings, as obtained from the newly built beam and from the Electrotechnical Laboratory's beam, respectively, are observed as a function of depth and exposure time due to the Xe-light irradiation. A high sensitivity of positron annihilation signal response to the early stage of degradation is observed. Development of positron annihilation spectroscopy to test accelerated weathering of polymeric coatings is discussed.

  7. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  8. Solvated Positron Chemistry. II

    DEFF Research Database (Denmark)

    Mogensen, O. E.

    1979-01-01

    The reaction of the hydrated positron, eaq+ with Cl−, Br−, and I− ions in aqueous solutions was studied by means of positron The measured angular correlation curves for [Cl−, e+], [Br−, e+, and [I−, e+] bound states were in good agreement with th Because of this agreement and the fact that the ca......The reaction of the hydrated positron, eaq+ with Cl−, Br−, and I− ions in aqueous solutions was studied by means of positron The measured angular correlation curves for [Cl−, e+], [Br−, e+, and [I−, e+] bound states were in good agreement with th Because of this agreement and the fact...... reactive. The rate constants were 3.9 × 1010 M−1 s−1, 4.4 × 1010 M−1 s−1, and 6.3 × 1010 M−1 s−1 for Cl−, Br−, and I−, respectively, at low (less, approximate 0.03 M) X− concentrations. A 25% decrease in the rate constant caused by the addition of 1 M ethanol to the I− solutions was i The influence...

  9. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  10. The Theory of Positrons

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 12. The Theory of Positrons. Richard P Feynman. Classics Volume 2 Issue 12 December 1997 pp 107-107. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/12/0107-0107. Author Affiliations.

  11. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  12. Positron annihilation processes update

    Science.gov (United States)

    Guessoum, Nidhal; Skibo, Jeffrey G.; Ramaty, Reuven

    1997-01-01

    The present knowledge concerning the positron annihilation processes is reviewed, with emphasis on the data of the cross sections of the various processes of interest in astrophysical applications. Recent results are presented including results on reaction rates and line widths, the validity of which is verified.

  13. A numerical study of the characteristics of the LEALE photon beam

    International Nuclear Information System (INIS)

    Lucherini, V.; De Sanctis, E.; Di Giacomo, P.

    1978-01-01

    At the LEALE laboratory a monochromatic photon beam with energy in the range 80/300 MeV is available. Photons are produced by positron annihilation on a liquid hydrogen target. The characteristics of the beam are calculated for various conditions (positron energy, photon collimator, target thickness), taking into account the effects contributing to the beam spreading (energy loss and multiple scattering of protons in the annihilation target, energy distribution and angular divergence of the positron beam). (author)

  14. Experimental studies on the photoelectron instability in the Beijing Electron Positron Collider

    Directory of Open Access Journals (Sweden)

    Z. Y. Guo

    2002-12-01

    Full Text Available A vertical coupled-bunch instability was observed for a positron beam at the Beijing Electron Positron Collider (BEPC. The experimental results show that the instability has similar characteristics as that observed in the Photon Factory of KEK several years ago. The instability at BEPC can be explained by the effect of an electron cloud which is produced in the beam chamber by synchrotron light hitting the wall.

  15. Positron annihilation in boron nitride

    Directory of Open Access Journals (Sweden)

    N.Amrane

    2006-01-01

    Full Text Available Electron and positron charge densities are calculated as a function of position in the unit cell for boron nitride. Wave functions are derived from pseudopotential band structure calculations and the independent particle approximation (IPM, respectively, for electrons and positrons. It is observed that the positron density is maximum in the open interstices and is excluded not only from ion cores but also to a considerable degree from valence bonds. Electron-positron momentum densities are calculated for (001,110 planes. The results are used in order to analyse the positron effects in BN.

  16. Simulation of tail distributions in electron-positron circular colliders

    Energy Technology Data Exchange (ETDEWEB)

    Irwin, J.

    1992-02-01

    In addition to the Gaussian shaped core region, particle bunches in electron-positron circular colliders have a rarefied halo region of importance in determining beam lifetimes and backgrounds in particle detectors. A method is described which allows simulation of halo particle distributions.

  17. Can positrons be guided by insulating capillaries?

    International Nuclear Information System (INIS)

    DuBois, R.D.; Toekesi, K.

    2011-01-01

    Complete text of publication follows. Investigations of guiding of few hundred eV antiparticles by macroscopic insulating capillaries have been described. Using subfemtoamp positron and electron beams, we demonstrated that a portion of the entering beams were transmitted and emerged in the direction of the capillary. We also demonstrated that the transmitted intensities decreased as the capillary tilt angle was increased (see Fig. 1). Both of these are indications of guiding. However, a comparison with transmitted photon data implies that the positron transmission may result from geometric factors associated with our diffuse beams and tapered capillary used in these studies. For electrons, the comparison indicates differences which could imply that even very low intensity beams can be guided. Measurements of the transmitted intensity as a function of charge entering the capillary were inconclusive as no major increases in the transmitted intensity were observed. 2D static simulations imply that our beam intensities, although extremely small with respect to previous guiding experiments, were capable of supplying sufficient charge for guiding to occur. Although not definitive, our study implies that sub-femtoamp beam intensities are sufficient to form charge patches and produce guiding. This may have been observed for electrons with the question remaining open for positrons. That guiding was not clearly seen may have been due to the capillary geometry used or it may indicate that although sufficient charge is being supplied, the surface and bulk resistivities of glass permit this charge to dissipate faster than it is formed. This aspect was not taken into consideration in our simulations but a crude estimate of the discharge rate implies that beam intensities on the order of pA, rather than fA as used here, may be required for guiding to occur in the capillaries used here. Additional studies are required to definitively answer the question as to whether antiparticles

  18. Positron emission tomography in epilepsy

    International Nuclear Information System (INIS)

    Hosokawa, Shinichi; Kato, Motohiro; Otsuka, Makoto; Kuwabara, Yasuo; Ichiya, Yuichi; Goto, Ikuo

    1989-01-01

    Positron emission tomography (PET) was performed with the 18 F-fluoro-deoxy-glucose method on 29 patients with epilepsy (generalized epilepsy, 4; partial epilepsy, 24; undetermined type, 1). The subjects were restricted to patients with epilepsy without focal abnormality on X-CT. All the patients with generalized epilepsy showed a normal pattern on PET. Fourteen out of the 24 patients with partial epilepsy and the 1 with epilepsy of undermined type showed focal hypometabolism on PET. The hypometabolic zone was localized in areas including the temporal cortex in 11 patients, frontal in 2 and thalamus in 1. The location of hypometabolic zone and that of interictal paroxysmal activity on EEG were well correlated in most patients. The patients with poorly-controlled seizure showed a higher incidence of PET abnormality (12 out of 13) than those with well-controlled seizures (2 out of 11). The incidence of abnormality on PET and MRI and the location of both abnormality were not necessarily coincident. These results indicated that the PET examination in epilepsy provides valuable information about the location of epileptic focus, and that the findings on PET in patients with partial epilepsy may be one of the good indicators about the intractability of partial epilepsy, and that PET and MRI provide complementary information in the diagnosis of epilepsy. (author)

  19. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  20. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  1. Efficient Cryosolid Positron Moderators

    Science.gov (United States)

    2012-08-01

    A.P. Mills Jr., K.G. Lynn, C.M. Surko, and D.M. Schrader for their patient explanations and helpful conversations. Any remaining misconceptions are... Chemistry and Physics, (Kluwer, Dordrecht, Netherlands, 2001). 3. Y.C. Jean, P.E. Mallon, and D.M. Schrader, eds., Principles and Applications of...Positron & Positronium Chemistry , (World Scientific Publishing, Singapore, 2003). 4. R.L. Forward and J. Davis, Mirror Matter, (iUniverse.com, Inc

  2. Positron emission mammography imaging

    OpenAIRE

    Moses, William W.

    2003-01-01

    This paper examines current trends in Positron Emission Mammography (PEM) instrumentation and the performance tradeoffs inherent in them. The most common geometry is a pair of parallel planes of detector modules. They subtend a larger solid angle around the breast than conventional PET cameras, and so have both higher efficiency and lower cost. Extensions to this geometry include encircling the breast, measuring the depth of interaction (DOI), and dual-modality imaging (PEM and x-ray mammogra...

  3. Development and applications of the positron microscope

    International Nuclear Information System (INIS)

    1991-01-01

    Progress on the positron microscope during the past year has been steady, and we currently project that initial microscope images can be collected during mid to late summer of 1992. Work during the year has mainly been divided among four areas of effort: hardware construction; power supply and control system development; radioactive source fabrication; and planning of initial experimental projects. Details of progress in these areas will be given below. An initial optical design of the microscope was completed during 1990, but during the past year, significant improvements have been made to this design, and several limiting cases of microscope performance have been evaluated. The results of these evaluations have been extremely encouraging, giving us strong indications that the optical performance of the microscope will be better than originally anticipated. In particular, we should be able to explore ultimate performance capabilities of positron microscopy using our currently planned optical system, with improvements only in the image detector system, and the positron-source/moderator configuration. We should be able to study imaging reemission microscopy with resolutions approaching 10 Angstrom and be able to produce beam spots for rastered microscope work with diameters below the 1000 Angstrom diffusion limit. Because of these exciting new possibilities, we have decided to upgrade several microscope subsystems to levels consistent with ultimate performance earlier in our construction schedule than we had previously intended. In particular, alignment facilities in the optical system, vibration isolation, and power supply and control system flexibility have all been upgraded in their design over the past year

  4. Incidence of Maxillary Sinus Disease Before Sinus Floor Elevation Surgery as Identified by Cone-Beam Computed Tomography: A Literature Review.

    Science.gov (United States)

    Costa, Fabio; Emanuelli, Enzo; Robiony, Massimo

    2018-04-01

    The purpose of this study is to review the literature to assess the incidence of maxillary sinus disease before sinus floor elevation surgery (SFE) as identified by cone-beam computerized tomography (CBCT). Only studies in which CBCT was performed in patients for dental implant placement in the past 10 years were considered. Eleven studies were identified. A total of 1792 patients were collected. All the studies reviewed reported on thickening of the sinus mucosa as a criterion for sinus disease with different threshold values. All studies reported mucosal thickening (MT) ranging between 25.5% and 93.1%. The mean incidence of MT was 54.99%. Two studies examined the correlation of MT with clinical symptoms. Three studies reported evaluation of the ostiomeatal complex (OMC). There is a high probability of detecting a certain degree of MT in patients referred for SFE. There is no consensus regarding the threshold values beyond which MT is considered pathological. Independently from the threshold values or the type of MT, the studies lack correlation with clinical data regarding patients' sinusitis-related history or symptoms. CBCT with a large field of view to evaluate the OMC is appropriate in patients scheduled for SFE. Future studies should include a systematic correlation with clinical symptoms and the possible presence of OMC obstruction. A clinical assessment that includes nasal endoscopy is indicated when MT and obstruction of the OMC are identified. Surgical correction of OMC obstruction seems to be appropriate to increase the success rate and to avoid possible complication after SFE.

  5. Positron annihilation Doppler broadening measurement for bulk amorphous alloy by using high energy positron generated from LCS gamma-ray at NEW SUBARU

    Science.gov (United States)

    Hori, F.; Ueno, Y.; Ishii, K.; Ishiyama, T.; Iwase, A.; Miyamoto, S.; Terasawa, T.

    2016-01-01

    A simple positron annihilation measurement apparatus via pair creation has been developed using high energetic gamma beam generated by laser Compton scattering (LCS) of 1 GeV electrons circulated in a storage ring and laser light with the power more than 1 W at the New SUBARU synchrotron radiation facility, University of Hyogo. This MeV ordered energy changeable positron apparatus is useful to study defects in bulk materials. In this study, the average energy of 8MeV positron was selected by the wavelength of laser light and circulated electron energy in photon factory. As a demonstrate of non-destruction positron measurement by this apparatus, positron annihilation Doppler broadening measurement has performed for bulk size of amorphous and crystal structured Zr based alloys. The larger Doppler broadening S parameter for amorphous alloy than that for crystallized one has been successfully measured.

  6. Recent improvements in the SLC positron system performance

    Energy Technology Data Exchange (ETDEWEB)

    Krejcik, P.; Corbett, J.; Ecklund, S.; Emma, P.; Fieguth, T.; Helm, R.; Kulikov, A.; Limberg, T.; Moshammer, H.; Ross, M.; Siemann, R.; Spence, W.; Woodley, M.

    1992-03-01

    The positron system is very specific to the SLC in that the positrons are accelerated in the same linac as the electrons that produce them and the electrons with which they collide. Some of the difficulties in tuning this system to peak performance are thus unlikely to be encountered in future linear colliders, but many of the lessons learned in beam matching are useful for future machines. The design and commissioning of this system has been previously reported so we only briefly describe the major subsystems before detailing the tuning and diagnostics involved in optimizing the performance of the overall system.

  7. Positron annihilation study on defects in ion-implanted Si

    International Nuclear Information System (INIS)

    Akahane, T.; Fujinami, M.; Sawada, T.

    2003-01-01

    Two-detector coincidence measurements of the Doppler broadened annihilation spectra with a variable energy positron beam are carried out for the study of the annealing behavior of Si implanted with As, P, Cu and H ions. In P-implanted Si, growth of the defect complexes are observed in coincidence Doppler broadening spectra up to 400degC. In Cu-implanted Si, the formation of defect-Cu complexes is indicated. In H-implanted Si, the passivation effect of hydrogen on positron traps are observed in the low temperature region up to 400degC. (author)

  8. Applications of positron depth profiling

    International Nuclear Information System (INIS)

    Hakvoort, R.A.

    1993-01-01

    In this thesis some contributions of the positron-depth profiling technique to materials science have been described. Following studies are carried out: Positron-annihilation measurements on neon-implanted steel; Void creation in silicon by helium implantation; Density of vacancy-type defects present in amorphous silicon prepared by ion implantation; Measurements of other types of amorphous silicon; Epitaxial cobalt disilicide prepared by cobalt outdiffusion. Positron-annihilation experiments on low-pressure CVD silicon-nitride films. (orig./MM)

  9. Nonlinear positron acoustic solitary waves

    International Nuclear Information System (INIS)

    Tribeche, Mouloud; Aoutou, Kamel; Younsi, Smain; Amour, Rabia

    2009-01-01

    The problem of nonlinear positron acoustic solitary waves involving the dynamics of mobile cold positrons is addressed. A theoretical work is presented to show their existence and possible realization in a simple four-component plasma model. The results should be useful for the understanding of the localized structures that may occur in space and laboratory plasmas as new sources of cold positrons are now well developed.

  10. Applications of positron depth profiling

    Energy Technology Data Exchange (ETDEWEB)

    Hakvoort, R.A.

    1993-12-23

    In this thesis some contributions of the positron-depth profiling technique to materials science have been described. Following studies are carried out: Positron-annihilation measurements on neon-implanted steel; Void creation in silicon by helium implantation; Density of vacancy-type defects present in amorphous silicon prepared by ion implantation; Measurements of other types of amorphous silicon; Epitaxial cobalt disilicide prepared by cobalt outdiffusion. Positron-annihilation experiments on low-pressure CVD silicon-nitride films. (orig./MM).

  11. Digitized detection of gamma-ray signals concentrated in narrow time windows for transient positron annihilation lifetime spectroscopy.

    Science.gov (United States)

    Kinomura, A; Suzuki, R; Oshima, N; O'Rourke, B E; Nishijima, T; Ogawa, H

    2014-12-01

    A pulsed slow-positron beam generated by an electron linear accelerator was directly used for positron annihilation lifetime spectroscopy without any positron storage devices. A waveform digitizer was introduced to simultaneously capture multiple gamma-ray signals originating from positron annihilation events during a single accelerator pulse. The positron pulse was chopped and bunched with the chopper signals also sent to the waveform digitizer. Time differences between the annihilation gamma-ray and chopper peaks were calculated and accumulated as lifetime spectra in a computer. The developed technique indicated that positron annihilation lifetime spectroscopy can be performed in a 20 μs time window at a pulse repetition rate synchronous with the linear accelerator. Lifetime spectra of a Kapton sheet and a thermally grown SiO2 layer on Si were successfully measured. Synchronization of positron lifetime measurements with pulsed ion irradiation was demonstrated by this technique.

  12. The effects of low-energy scattering on positron implantation

    Energy Technology Data Exchange (ETDEWEB)

    Ritley, K.A. (Dept. of Physics and Materials Research Laboratory, Univ. of Illinois, Urbana, IL (United States)); Lynn, K.G.; Ghosh, V.; Welch, D.O. (Brookhaven National Lab., Upton, NY (United States))

    1992-01-01

    Existing Monte Carlo models are capable of simulating the behavior of positrons incident at keV energies, then following the energy loss process to arbitrary final kinetic energies of from 20 eV to 100 eV. This work describes a Monte Carlo simulation of the final stages of positron thermalization in Al, from 25 eV to thermal energies, via the mechanisms of conduction-electron and longitudinal acoustic phonon scattering. The latter stages of thermalization can have important effects on the stopping profiles and mean depth. A novel way to obtain information about positron energy loss by considering the time-evolution of a point-concentration (delta-function distribution) of positrons is described. The effects of a positive positron work function are examined for the first time in the context of a positron Monte Carlo calculation. Finally, some issues relating to the agreement of Monte Carlo calculations with experimental data are discussed. 6 figs., 16 refs.

  13. The effects of low-energy scattering on positron implantation

    Energy Technology Data Exchange (ETDEWEB)

    Ritley, K.A. [Dept. of Physics and Materials Research Laboratory, Univ. of Illinois, Urbana, IL (United States); Lynn, K.G.; Ghosh, V.; Welch, D.O. [Brookhaven National Lab., Upton, NY (United States)

    1992-12-31

    Existing Monte Carlo models are capable of simulating the behavior of positrons incident at keV energies, then following the energy loss process to arbitrary final kinetic energies of from 20 eV to 100 eV. This work describes a Monte Carlo simulation of the final stages of positron thermalization in Al, from 25 eV to thermal energies, via the mechanisms of conduction-electron and longitudinal acoustic phonon scattering. The latter stages of thermalization can have important effects on the stopping profiles and mean depth. A novel way to obtain information about positron energy loss by considering the time-evolution of a point-concentration (delta-function distribution) of positrons is described. The effects of a positive positron work function are examined for the first time in the context of a positron Monte Carlo calculation. Finally, some issues relating to the agreement of Monte Carlo calculations with experimental data are discussed. 6 figs., 16 refs.

  14. Reduction of the divergence angle of an incident beam to enhance the demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system of several tens of keV

    Science.gov (United States)

    Ishii, Yasuyuki; Kojima, Takuji

    2018-04-01

    The demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system that produces ion beams with energies in the order of 10 keV was enhanced in this study so that a hydrogen ion beam with a diameter of 115 nm could be produced. The reduction of the divergence angle of the incident beam into the two-stage acceleration lens is the effective method for enhancing the demagnification factor. The divergence angle has been gradually reduced by firstly introducing the preacceleration electrodes to control the divergence angle, namely divergence-angle-control electrodes, and secondly replacing an anode with a modified anode that possesses a Pierce electrode, both of which were in an ion source directly connected to the lens. In this study, the divergence angle of less than 3.6 × 10-4 rad that was previously used to produce a 160-nm hydrogen ion beam with the energy of 46 keV by the above procedure was numerically determined using an ion beam extraction simulation code. The determined minimum divergence angle of the incident ion beam was calculated to be 2.0 × 10-4 rad, which was about half of the previously obtained divergence angle; this was used to experimentally form a hydrogen beam with a diameter of 115 ± 10 nm and the energy of 47 keV. The demagnification factor was estimated to be 1,739 using the newly formed hydrogen beam, which was similar to the simulation result.

  15. Progress toward magnetic confinement of a positron-electron plasma: nearly 100% positron injection efficiency into a dipole trap

    Science.gov (United States)

    Stoneking, Matthew

    2017-10-01

    The hydrogen atom provides the simplest system and in some cases the most precise one for comparing theory and experiment in atomics physics. The field of plasma physics lacks an experimental counterpart, but there are efforts underway to produce a magnetically confined positron-electron plasma that promises to represent the simplest plasma system. The mass symmetry of positron-electron plasma makes it particularly tractable from a theoretical standpoint and many theory papers have been published predicting modified wave and stability properties in these systems. Our approach is to utilize techniques from the non-neutral plasma community to trap and accumulate electrons and positrons prior to mixing in a magnetic trap with good confinement properties. Ultimately we aim to use a levitated superconducting dipole configuration fueled by positrons from a reactor-based positron source and buffer-gas trap. To date we have conducted experiments to characterize and optimize the positron beam and test strategies for injecting positrons into the field of a supported permanent magnet by use of ExB drifts and tailored static and dynamic potentials applied to boundary electrodes and to the magnet itself. Nearly 100% injection efficiency has been achieved under certain conditions and some fraction of the injected positrons are confined for as long as 400 ms. These results are promising for the next step in the project which is to use an inductively energized high Tc superconducting coil to produce the dipole field, initially in a supported configuration, but ultimately levitated using feedback stabilization. Work performed with the support of the German Research Foundation (DFG), JSPS KAKENHI, NIFS Collaboration Research Program, and the UCSD Foundation.

  16. Positron lifetimes in deformed copper

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Doyama, Masao

    1976-01-01

    Positron lifetime measurements were performed for Cu samples with different densities of lattice defects. The lifetime spectra were successfully resolved into two components with the help of the well established analysis program. Obtained results were quite consistent with those expected from the trapping model. The positron trapping mechanism from free to trapped states and the initial condition of the model were especially checked. Deduced values obtained for tau sub(c) (lifetime of free positrons) and tau sub(t) (lifetime of trapped positrons) were 122+-5 psec and 176+-5 psec, respectively. (auth.)

  17. First on-line positron experiments en route to pair-plasma creation

    Energy Technology Data Exchange (ETDEWEB)

    Stanja, Juliane; Hergenhahn, Uwe; Stenson, Eve V. [Max-Planck-Institut fuer Plasmaphysik (Germany); Niemann, Holger; Sunn Pedersen, Thomas [Max-Planck-Institut fuer Plasmaphysik (Germany); Ernst-Moritz-Arndt Universitaet Greifswald (Germany); Saitoh, Haruhiko [Max-Planck-Institut fuer Plasmaphysik (Germany); The University of Tokyo (Japan); Stoneking, Matthew R. [Lawrence University (United States); Hugenschmidt, Christoph; Piochacz, Christian [Technische Universitaet Muenchen (Germany); Schweikhard, Lutz [Ernst-Moritz-Arndt Universitaet Greifswald (Germany)

    2016-07-01

    Electron-positron plasmas are predicted to show a fundamentally different behavior from traditional ion-electron plasmas, because of the equal masses of the two species. Using up to 10{sup 9} positrons per second provided by the NEPOMUC (Neutron-Induced Positron Source Munich) facility, the APEX/PAX team aims to create the first such plasma confined in a toroidal magnetic trap. Positron beam parameters as well as efficient injection and confinement schemes for both species in toroidal geometries are fundamental to the project. In this contribution we present results from first on-line positron experiments. Besides characterizing the NEPOMUC beam we conducted positron injection experiments into a dipole magnetic field configuration. Using static electric fields, a 5-eV positron beam was transported across magnetic field lines into the confinement region. With this method, up to 38% of the incoming particles reach the confinement region and make at least a 180 revolution around the magnet. Under dedicated experimental conditions confinement on the order of 1 ms was realized.

  18. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  19. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  20. Quantum positron acoustic waves

    Energy Technology Data Exchange (ETDEWEB)

    Metref, Hassina; Tribeche, Mouloud [Plasma Physics Group (PPG), Theoretical Physics Laboratory (TPL), Faculty of Physics, University of Bab-Ezzouar, USTHB, B.P. 32, El Alia, Algiers 16111 (Algeria)

    2014-12-15

    Nonlinear quantum positron-acoustic (QPA) waves are investigated for the first time, within the theoretical framework of the quantum hydrodynamic model. In the small but finite amplitude limit, both deformed Korteweg-de Vries and generalized Korteweg-de Vries equations governing, respectively, the dynamics of QPA solitary waves and double-layers are derived. Moreover, a full finite amplitude analysis is undertaken, and a numerical integration of the obtained highly nonlinear equations is carried out. The results complement our previously published results on this problem.

  1. Use of Radioactive Ion Beams for Biomedical Research 2. in-vivo dosimetry using positron emitting rare earth isotopes with the rotating prototype PET scanner at the Geneva Cantonal Hospital

    CERN Multimedia

    2002-01-01

    % IS331 \\\\ \\\\ The use of radioactive metal ions (such as $^{90}$Y, $^{153}$Sm or $^{186}$Re) in cancer therapy has made some progress, but has been hampered by factors that could be addressed at CERN with a greater likelihood of success than at any other installation in the world. The present proposal seeks to use the unique advantage of CERN ISOLDE to get round these problems together with the PET scanners at the Cantonal Hospital Geneva (PET~=~positron emission tomography). Radioisotope production by spallation at ISOLDE makes available a complete range of isotopes having as complete a diversity of types and energy of radiation, of half-life, and of ionic properties as one would wish. Among these isotopes several positron-emitters having clinical relevance are available.\\\\ \\\\Some free rare earth chelatas are used presently in palliation of painful bone metastases. Curative effects are not able for the moment with this kind of radiopharmaceuticals. More and better data on the biokinetics and bio-distribution...

  2. Positron emission tomography in a national research centre

    International Nuclear Information System (INIS)

    Weinreich, R.

    1989-01-01

    The example of the Paul Scherrer Institute shows that positron emission tomography can be implanted successfully as spin-off into an appropriate environment. The adaption to the existing irradiation facilities of the technique of production of the short-lived positron emitters is complex. However, the basic necessities of a tomography programme can be covered. Moreover, the relatively high energy of the institute's injector cyclotron allows additional production of rare-used longer-lived positron emitters. The scanner exceeded the guaranteed specifications. With respect to the somewhat lower availability of beam time compared to a usual baby cyclotron, the research programme must not be very patient-intense. A strong participation of the pharmaceutical industry has directed research priorities into the pharmacological area. (orig.) [de

  3. Cyclotrons and positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs

  4. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  5. Elastic scattering of positrons off rare-gas atoms

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, S.; Talukdar, B. (Department of Physics, Visva-Bharati University, Santiniketan-731 235 (India)); Mandal, P. (Department of Mathematics, Visva-Bharati University, Santiniketan-731 235 (India))

    1995-01-01

    A simple potential model proposed for the elastic scattering of positrons off rare-gas atoms is used to compute low-energy phase shifts and differential scattering cross sections [sigma]([theta]) for positrons incident on [sub 10]Ne, [sub 18]Ar, and [sub 36]Kr at energies 20, 3.4, and 6.67 eV, respectively. The calculated results for [sigma]([theta]) are in good agreement with currently available experimental values and are as reliable as the numbers obtained from much more elaborate calculations. It is pointed out that an important virtue of the present model is its simplicity.

  6. Positron Production in Multiphoton Light-by-Light Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Koffas, Thomas

    2003-07-28

    We present the results of an experimental study on e{sup +}e{sup -} pair production during the collision of a low emittance 46.6 GeV electron beam with terawatt laser pulses from a Nd:glass laser at 527 nm wavelength and with linear polarization. The experiment was conducted at the Final Focus Test Beam facility in the Stanford Linear Accelerator Center. Results with a 49.1 GeV electron beam are also included. A signal of 106 {+-} 14 positrons for the 46.6 GeV electron beam case and of 22 {+-} 10 positrons for the 49.1 GcV case above background, has been detected. We interpret the positrons as the products of a two-step process during which laser photons are backscattered to high energy gamma photons that absorb in their turn several laser photons in order to produce a e{sup +}e{sup -} pair. The data compare well with the existing theoretical models. This is the first observation in the laboratory of inelastic Light-by-Light scattering with only real photons. Alternatively, the data are interpreted as a manifestation of the spontaneous breakdown of the vacuum under the influence of an intense external alternating electric field.

  7. ILC beam energy measurement by means of laser Compton backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Muchnoi, N. [Budker Inst. for Nuclear Physics, Novosibirsk (Russian Federation); Schreiber, H.J.; Viti, M. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2008-10-15

    A novel, non-invasive method of measuring the beam energy at the International Linear Collider is proposed. Laser light collides head-on with beam particles and either the energy of the Compton scattered electrons near the kinematic end-point is measured or the positions of the Compton backscattered {gamma}-rays, the edge electrons and the unscattered beam particles are recorded. A compact layout for the Compton spectrometer is suggested. It consists of a bending magnet and position sensitive detectors operating in a large radiation environment. Several options for high spatial resolution detectors are discussed. Simulation studies support the use of an infrared or green laser and quartz fiber detectors to monitor the backscattered photons and edge electrons. Employing a cavity monitor, the beam particle position downstream of the magnet can be recorded with submicrometer precision. Such a scheme provides a feasible and promising method to access the incident beam energy with precisions of 10{sup -4} or better on a bunch-to-bunch basis while the electron and positron beams are in collision. (orig.)

  8. A comparison of simple and realistic eye models for calculation of fluence to dose conversion coefficients in a broad parallel beam incident of protons

    International Nuclear Information System (INIS)

    Sakhaee, Mahmoud; Vejdani-Noghreiyan, Alireza; Ebrahimi-Khankook, Atiyeh

    2015-01-01

    Radiation induced cataract has been demonstrated among people who are exposed to ionizing radiation. To evaluate the deterministic effects of ionizing radiation on the eye lens, several papers dealing with the eye lens dose have been published. ICRP Publication 103 states that the lens of the eye may be more radiosensitive than previously considered. Detailed investigation of the response of the lens showed that there are strong differences in sensitivity to ionizing radiation exposure with respect to cataract induction among the tissues of the lens of the eye. This motivated several groups to look deeper into issue of the dose to a sensitive cell population within the lens, especially for radiations with low energy penetrability that have steep dose gradients inside the lens. Two sophisticated mathematical models of the eye including the inner structure have been designed for the accurate dose estimation in recent years. This study focuses on the calculations of the absorbed doses of different parts of the eye using the stylized models located in UF-ORNL phantom and comparison with the data calculated with the reference computational phantom in a broad parallel beam incident of protons with energies between 20 MeV and 10 GeV. The obtained results indicate that the total lens absorbed doses of reference phantom has good compliance with those of the more sensitive regions of stylized models. However, total eye absorbed dose of these models greatly differ with each other for lower energies. - Highlights: • The validation of reference data for the eye was studied for proton exposures. • Two real mathematical models of the eye were imported into the UF-ORNL phantom. • Fluence to dose conversion coefficients were calculated for different eye sections. • Obtained Results were compared with that of assessed by ICRP adult male phantom

  9. Four-dimensional positron age-momentum correlation

    Science.gov (United States)

    Ackermann, Ulrich; Löwe, Benjamin; Dickmann, Marcel; Mitteneder, Johannes; Sperr, Peter; Egger, Werner; Reiner, Markus; Dollinger, Günther

    2016-11-01

    We have performed first four-dimensional age-momentum correlation (4D-AMOC) measurements at a pulsed high intensity positron micro beam and determined the absolute value of the three-dimensional momentum of the electrons annihilating with the positrons in coincidence with the positron age in the sample material. We operated two position sensitive detectors in coincidence to measure the annihilation radiation: a pixelated HPGe-detector and a microchannel plate image intensifier with a CeBr3 scintillator pixel array. The transversal momentum resolution of the 4D-AMOC setup was measured to be about 17 × 10-3 {m}0c (FWHM) and was circa 3.5 times larger than the longitudinal momentum resolution. The total time resolution was 540 ps (FWHM). We measured two samples: a gold foil and a carbon tape at a positron implantation energy of 2 keV. For each sample discrete electron momentum states and their respective positron lifetimes were extracted.

  10. Electron and positron atomic elastic scattering cross sections

    International Nuclear Information System (INIS)

    Stepanek, Jiri

    2003-01-01

    A method was developed to calculate the total and differential elastic-scattering cross sections for incident electrons and positrons in the energy range from 0.01 eV to 1 MeV for atoms of Z=1-100. For electrons, hydrogen, helium, nitrogen, oxygen, krypton, and xenon, and for positrons, helium, neon, and argon atoms were considered for comparison with experimental data. First, the variationally optimized atomic static potentials were calculated for each atom by solving the Dirac equations for bound electron states. Second, the Dirac equations for a free electron or positron are solved for an atom using the previously calculated static potential accomplished (in the case of electrons) by 'adjusted' Hara's exchange potential for a free-state particle. Additional to the exchange effects, the charge cloud polarization effects are considered applying the correlation-polarization potential of O'Connell and Lane (with correction of Padial and Norcross) for incident electrons, and of Jain for incident positrons. The total, cutoff and differential elastic-scattering cross sections are calculated for incident electrons and positrons with the help of the relativistic partial wave analysis. The solid state effects for scattering in solids are described by means of a muffin-tin model, i.e. the potentials of neighboring atoms are superpositioned in such a way that the resulting potential and its derivative are zero in the middle distance between the atoms. The potential of isolated atom is calculated up to the radius at which the long-range polarization potential becomes a value of -10 -8

  11. Beam-beam deflections as an interaction point diagnostic for the SLC

    International Nuclear Information System (INIS)

    Bambade, P.; Erickson, R.

    1986-05-01

    A technique is described for non-destructive measurement and monitoring of the steering offset of the electron and positron beams at the interaction point of the SLC, based on using stripline beam-position monitors to measure the centroid of one beam as it is deflected by the opposing beam. This technique is also expected to provide diagnostic information related to the spot size of the micron-size beams

  12. On Positronium Formation in Crystalline and Amorphous Ice at Low Positron Energy

    DEFF Research Database (Denmark)

    Mogensen, O. E.

    1986-01-01

    The positronium (Ps) yield for ice, measured by Eldrup et al. using a low-energy positron beam, is discussed in terms of the spur model of Ps formation. The pronounced maxima in the Ps yield for crystalline ice at positron energies below 65 eV are well explained by effects due to energy conservat...... conservation in the spur processes. Parts of the amorphous ice results are well explained by the spur but not by the Ore model. Important processes influencing the Ps formation are not included in the Ore model.......The positronium (Ps) yield for ice, measured by Eldrup et al. using a low-energy positron beam, is discussed in terms of the spur model of Ps formation. The pronounced maxima in the Ps yield for crystalline ice at positron energies below 65 eV are well explained by effects due to energy...

  13. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  14. Positron Emission Mammography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Moses, W.W. E-mail: wwmoses@lbl.gov

    2004-06-01

    This paper examines current trends in Positron Emission Mammography (PEM) instrumentation and the performance tradeoffs inherent in them. The most common geometry is a pair of parallel planes of detector modules. They subtend a larger solid angle around the breast than conventional PET cameras, and so have both higher efficiency and lower cost. Extensions to this geometry include encircling the breast, measuring the depth of interaction (DOI), and dual-modality imaging (PEM and X-ray mammography, as well as PEM and X-ray guided biopsy). The ultimate utility of PEM may not be decided by instrument performance, but by biological and medical factors, such as the patient to patient variation in radiotracer uptake or the as yet undetermined role of PEM in breast cancer diagnosis and treatment.

  15. Positron emission mammography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Moses, William W.

    2003-10-02

    This paper examines current trends in Positron Emission Mammography (PEM) instrumentation and the performance tradeoffs inherent in them. The most common geometry is a pair of parallel planes of detector modules. They subtend a larger solid angle around the breast than conventional PET cameras, and so have both higher efficiency and lower cost. Extensions to this geometry include encircling the breast, measuring the depth of interaction (DOI), and dual-modality imaging (PEM and x-ray mammography, as well as PEM and x-ray guided biopsy). The ultimate utility of PEM may not be decided by instrument performance, but by biological and medical factors, such as the patient to patient variation in radiotracer uptake or the as yet undetermined role of PEM in breast cancer diagnosis and treatment.

  16. Positrons as imaging agents and probes in nanotechnology

    International Nuclear Information System (INIS)

    Smith, Suzanne V

    2009-01-01

    Positron emission tomography (PET) tracks a positron emitting radiopharmaceutical injected into the body and generates a 3-dimensional image of its location. Introduced in the early 70s, it has now developed into a powerful medical diagnostic tool for routine clinical use as well as in drug development. Unrivalled as a highly sensitive, specific and non-invasive imaging tool, PET unfortunately lacks the resolution of Computer Tomography (CT) and Magnetic Resonance Imaging (MRI). As the resolution of PET depends significantly on the energy of the positron incorporated in the radiopharmaceutical and its interaction with its surrounding tissue, there is growing interest in expanding our understanding of how positrons interact at the atomic and molecular level. A better understanding of these interactions will contribute to improving the resolution of PET and assist in the design of better imaging agents. Positrons are also used in Positron Annihilation Lifetime Spectroscopy (PALS) to determine electron density and or presence and incidence of micro- and mesopores (0.1 to 10 nm) in materials. The control of porosity in engineered materials is crucial for applications such as controlled release or air and water resistant films. Equally important to the design of nano and microtechnologies, is our understanding of the microenvironments within these pores and on surfaces. Hence as radiopharmaceuticals are designed to track disease, nuclear probes (radioactive molecules) are synthesized to investigate the chemical properties within these pores. This article will give a brief overview of the present role of positrons in imaging as well as explore its potential to contribute in the engineering of new materials to the marketplace.

  17. A test beam upgrade based on the BEPC-LINAC

    International Nuclear Information System (INIS)

    Li Jiacai; Wu Yuanming; Cui Xiangzong; Zhang Liangsheng; Zhou Baoqing; Liu Zhengquan; Zhang Shaoping; Sun Changchun; Zhang Zhuxiang; Zhang Caidi; Zheng Linsheng; Liu Shixing; Shen Ji; Yin Zejie; Zhang Yongming; Chen Ziyu

    2004-01-01

    A total of three beam lines, E1, E2 and E3 have based on the LINAC of BEPC. The E1 beam is to be used for intense slow-positron facility. The E2 is a primary positron or electron beam with an energy of 1.3-1.5 GeV. The E3 is a secondary electron or pion test beam with a momentum can be adjustable continuously. The position accuracy of a detected particle is 0.2-0.4 mm with an event rate of 3 - 4 Hz. This beam has been successfully used for some detectors beam test. (author)

  18. Fundamentals of positron emission tomography

    International Nuclear Information System (INIS)

    Ostertag, H.

    1989-01-01

    Positron emission tomography is a modern radionuclide method of measuring physiological quantities or metabolic parameters in vivo. The methods is based on: (1) Radioactive labelling with positron emitters; (2) the coincidence technique for the measurement of the annihilation radiation following positron decay; (3) analysis of the data measured using biological models. The basic aspects and problems of the method are discussed. The main fields of future research are the synthesis of new labelled compounds and the development of mathematical models of the biological processes to be investigated. (orig.) [de

  19. Development of Electron-positron Screened Pseudopotential ...

    African Journals Online (AJOL)

    In the jellium model, for electron-positron annihilation to take place, the positron must overcome the screened potential of the valence electrons. In this paper, we develop electron-positron screened pseudopotential to explain positron annihilation rate in metals. The results obtained show that there is a trend in the variation ...

  20. Detectors for high resolution dynamic positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1985-01-01

    Tomography is the technique of producing a photographic image of an opaque specimen by transmitting a beam of x-rays or gamma rays through the specimen onto an adjacent photographic film. The image results from variations in thickness, density, and chemical composition, of the specimen. This technique is used to study the metabolism of the human brain. This article examines the design of equipment used for high resolution dynamic positron emission tomography. 27 references, 5 figures, 3 tables

  1. Positron lifetime study of electron-irradiated epoxy resins

    International Nuclear Information System (INIS)

    Suevegh, K.; Vertes, A.; Wojnarovits, L.; Foeldiak, G.; Liszkai, L.; Kajcsos, Zs.

    1990-01-01

    Two bisphenol-A type epoxy resins were irradiated by electron beam and studied afterwards by positron lifetime spectroscopy. An interesting result is that despite of the considerable amount of free-radicals, no inhibition of positronium formation was observed in the two epoxies. Nevertheless, several serious differences were detected between the studied polymers. The results suggest that the radiation-resistant properties of epoxies depend strongly on the amount of the curing agent. (author) 8 refs.; 2 figs

  2. Electron fluence to dose equivalent conversion factors calculated with EGS3 for electrons and positrons with energies from 100 keV to 20 GeV

    International Nuclear Information System (INIS)

    Rogers, D.W.O.

    1983-01-01

    At NRC the general purpose Monte-Carlo electron-photon transport code EGS3 is being applied to a variety of radiation dosimetry problems. To test its accuracy at low energies a detailed set of depth-dose curves for electrons and photons has been generated and compared to previous calculations. It was found that by changing the default step-size algorithm in EGS3, significant changes were obtained for incident electron beam cases. It was found that restricting the step-size to a 4% energy loss was appropriate below incident electron beam energies of 10 MeV. With this change, the calculated depth-dose curves were found to be in reasonable agreement with other calculations right down to incident electron energies of 100 keV although small (less than or equal to 10%) but persistent discrepancies with the NBS code ETRAN were obtained. EGS3 predicts higher initial dose and shorter range than ETRAN. These discrepancies are typical of a wide range of energies as is the better agreement with the results of Nahum. Data is presented for the electron fluence to maximal dose equivalent in a 30 cm thick slab of ICRU 4-element tissue irradiated by broad parallel beams of electrons incident normal to the surface. On their own, these values only give an indication of the dose equivalent expected from a spectrum of electrons since one needs to fold the spectrum maximal dose equivalent value. Calculations have also been done for incident positron beams. Despite the large statistical uncertainties, maximal dose equivalent although their values are 5 to 10% lower in a band around 10 MeV

  3. Brilliant positron sources for CLIC and other collider projects

    CERN Document Server

    Rinolfi, Louis; Dadoun, Olivier; Kamitani, Takuya; Strakhovenko, Vladimir; Variola, Alessandro

    2013-01-01

    The CLIC (Compact Linear Collider), as future linear collider, requires an intense positron source. A brief history is given up to the present baseline configuration which assumes unpolarized beams. A conventional scheme, with a single tungsten target as source of e-e+ pairs, has been studied several years ago. But, in order to reduce the beam energy deposition on the e+ target converter, a double-target system has been studied and proposed as baseline for CLIC. With this ‘‘hybrid target’’, the positron production scheme is based on the channeling process. A 5 GeV electron beam impinges on a thin crystal tungsten target aligned along its axis, enhancing the photon production by channeling radiation. A large number of photons are sent to a thick amorphous tungsten target, generating large number of e-e+ pairs, while the charged particles are bent away, reducing the deposited energy and the PEDD (Peak Energy Deposition Density). The targets parameters are optimized for the positron production. Polarize...

  4. Positron annihilation in superconductive metals

    Energy Technology Data Exchange (ETDEWEB)

    Dekhtjar, I.J.

    1969-03-10

    A correlation is shown between the parameters of superconductive metals and those of positron annihilation. Particular attention is paid to the density states obtained from the electron specific heat.

  5. Parkinson disease and positron tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1984-10-01

    Physiopathologic investigations of Parkinson disease and parkinsonian syndrome using positron tomography are briefly reviewed: study of cerebral blood flow and metabolism; effects of L-DOPA; study of dopaminergic receptors and of 18 F-Fluoro-L-DOPA incorporation [fr

  6. Deconvolution of Positrons' Lifetime spectra

    International Nuclear Information System (INIS)

    Calderin Hidalgo, L.; Ortega Villafuerte, Y.

    1996-01-01

    In this paper, we explain the iterative method previously develop for the deconvolution of Doppler broadening spectra using the mathematical optimization theory. Also, we start the adaptation and application of this method to the deconvolution of positrons' lifetime annihilation spectra

  7. Positron diffusion in noble gases

    International Nuclear Information System (INIS)

    Stromswold, D.C.; Lee, Y.K.

    1975-01-01

    Positron diffusion in helium, neon, and argon has been observed and the lifetimes of free positrons in these gases have been calculated on the basis of assumed theoretical behavior. The results are summarized for various gas pressures at room temperature. Reported lifetimes are comparable to the extrapolated values of 1.4 μsec in He and 0.2 μsec in Ar obtained at one atmosphere by Falk. (7 figures, 2 tables) (U.S.)

  8. Electron--positron storage ring PETRA: plans and status

    International Nuclear Information System (INIS)

    Voss, G.A.

    1977-01-01

    Construction of the Electron-Positron Storage Ring PETRA was authorized October 20, 1975. At present most of the civil engineering work is completed and ring installation work is under way. All major components are on order and series production of bending magnets, quadrupoles, vacuum chambers and rf-resonators has started. Start-up of the machine is planned with a fourfold symmetry configuration with four active beam-beam interaction points. Five experimental facilities have been recommended for the first round of experiments scheduled to begin mid 79

  9. Study of a positron source generated by photons from ultrarelativistic channeled particles

    International Nuclear Information System (INIS)

    Chehab, R.; Couchot, F.; Nyaiesh, A.R.; Richard, F.; Artru, X.

    1989-03-01

    Radiation by channeled electrons in Germanium and Silicon crystals along the axis is studied as a very promising photon source of small angular divergence for positron generation in amorphous targets. Radiation rates for different crystal lengths - from some tenths of mm to 10 mm - and two electron incident energies, 5 and 20 GeV, are considered and a comparison between the two crystals is presented. Thermic behaviour of the crystal under incidence of bunches of 10 10 electrons is also examined. The corresponding positron yields for tungsten amorphous converters - of 0.5 and 1 X o thickness - are calculated considering the case of a Germanium photon generator. Assuming a large acceptance optical matching system as the adiabatic device of the SLC, accepted positrons are evaluated and positron yields larger than 1 e + /e - are obtained

  10. Single Bunch Electron Cloud Effects in the NLC Beam Delivery System(LCC-0126)

    Energy Technology Data Exchange (ETDEWEB)

    Chen, D

    2003-12-08

    A positron beam passing through a linear collider beam delivery beam line is finely focused to desired specifications during collimation and especially in Final Focusing (FFS). Undesired additional focusing is generated by beam-electron cloud interactions, which typically leads to beam size increases at high cloud densities. This paper examines the severity of the electron cloud effects and assesses the critical cloud density.

  11. Uniformity of the soft-x-ray emissions from gold foils irradiated by OMEGA laser beams determined by a two-mirror normal-incidence microscope with multilayer coatings

    International Nuclear Information System (INIS)

    Seely, John F.; Boehly, Thomas; Pien, Gregory; Bradley, David

    1998-01-01

    A two-mirror normal-incidence microscope with multilayer coatings was used to image the soft-x-ray emissions from planar foils irradiated by OMEGA laser beams. The bandpass of the multilayer coatings was centered at a wavelength of 48.3 Angstrom (257-eV energy) and was 0.5 Angstrom wide. Five overlapping OMEGA beams, without beam smoothing, were typically incident on the gold foils. The total energy was 1500 J, and the focused intensity was 6x10 13 Wcm -2 . The 5.8x magnified images were recorded by a gated framing camera at various times during the 3-ns laser pulse. A pinhole camera imaged the x-ray emission in the energy range of >2 keV. On a spatial scale of 10 μm, it was found that the soft-x-ray images at 257 eV were quite uniform and featureless. In contrast, the hard-x-ray images in the energy range of >2 kev were highly nonuniform with numerous features of size 150 μm. copyright 1998 Optical Society of America

  12. Method for photon activation positron annihilation analysis

    Science.gov (United States)

    Akers, Douglas W.

    2006-06-06

    A non-destructive testing method comprises providing a specimen having at least one positron emitter therein; determining a threshold energy for activating the positron emitter; and determining whether a half-life of the positron emitter is less than a selected half-life. If the half-life of the positron emitter is greater than or equal to the selected half-life, then activating the positron emitter by bombarding the specimen with photons having energies greater than the threshold energy and detecting gamma rays produced by annihilation of positrons in the specimen. If the half-life of the positron emitter is less then the selected half-life, then alternately activating the positron emitter by bombarding the specimen with photons having energies greater then the threshold energy and detecting gamma rays produced by positron annihilation within the specimen.

  13. Resonance scattering of a dielectric sphere illuminated by electromagnetic Bessel non-diffracting (vortex) beams with arbitrary incidence and selective polarizations

    Energy Technology Data Exchange (ETDEWEB)

    Mitri, F.G., E-mail: F.G.Mitri@ieee.org [Chevron, Area 52 Technology–ETC, 5 Bisbee Ct., Santa Fe, NM 87508 (United States); Li, R.X., E-mail: rxli@mail.xidian.edu.cn [School of Physics and Optoelectronic Engineering, Xidian University, Xi’an 710071 (China); Collaborative Innovation Center of Information Sensing and Understanding, Xidian University, Xi’an 710071 (China); Guo, L.X. [School of Physics and Optoelectronic Engineering, Xidian University, Xi’an 710071 (China); Collaborative Innovation Center of Information Sensing and Understanding, Xidian University, Xi’an 710071 (China); Ding, C.Y. [School of Physics and Optoelectronic Engineering, Xidian University, Xi’an 710071 (China)

    2015-10-15

    A complete description of vector Bessel (vortex) beams in the context of the generalized Lorenz–Mie theory (GLMT) for the electromagnetic (EM) resonance scattering by a dielectric sphere is presented, using the method of separation of variables and the subtraction of a non-resonant background (corresponding to a perfectly conducting sphere of the same size) from the standard Mie scattering coefficients. Unlike the conventional results of standard optical radiation, the resonance scattering of a dielectric sphere in air in the field of EM Bessel beams is examined and demonstrated with particular emphasis on the EM field’s polarization and beam order (or topological charge). Linear, circular, radial, azimuthal polarizations as well as unpolarized Bessel vortex beams are considered. The conditions required for the resonance scattering are analyzed, stemming from the vectorial description of the EM field using the angular spectrum decomposition, the derivation of the beam-shape coefficients (BSCs) using the integral localized approximation (ILA) and Neumann–Graf’s addition theorem, and the determination of the scattering coefficients of the sphere using Debye series. In contrast with the standard scattering theory, the resonance method presented here allows the quantitative description of the scattering using Debye series by separating diffraction effects from the external and internal reflections from the sphere. Furthermore, the analysis is extended to include rainbow formation in Bessel beams and the derivation of a generalized formula for the deviation angle of high-order rainbows. Potential applications for this analysis include Bessel beam-based laser imaging spectroscopy, atom cooling and quantum optics, electromagnetic instrumentation and profilometry, optical tweezers and tractor beams, to name a few emerging areas of research.

  14. Revealing Fundamental Interactions: the Role of Polarized Positrons and Electrons at the Linear Collider

    Energy Technology Data Exchange (ETDEWEB)

    Moortgat-Pick, G.; /CERN /Durham U., IPPP; Abe, T.; Alexander, G.; Ananthanarayan, B.; Babich, A.A.; Bharadwaj, V.; Barber, D.; Bartl, A.; Brachmann, A.; Chen, S.; Clarke,; Clendenin, J.E.; Dainton, J.; Desch, K.; Diehl, M.; Dobos, B.; Dorland, T.; Eberl, H.; Ellis, John R.; Flottman, K.; Frass, H.; /CERN /Durham U., IPPP /Colorado U. /Tel-Aviv

    2005-07-06

    The proposed International Linear Collider (ILC) is well-suited for discovering physics beyond the Standard Model and for precisely unraveling the structure of the underlying physics. The physics return can be maximized by the use of polarized beams. This report shows the paramount role of polarized beams and summarizes the benefits obtained from polarizing the positron beam, as well as the electron beam. The physics case for this option is illustrated explicitly by analyzing reference reactions in different physics scenarios. The results show that positron polarization, combined with the clean experimental environment provided by the linear collider, allows to improve strongly the potential of searches for new particles and the identification of their dynamics, which opens the road to resolve shortcomings of the Standard Model. The report also presents an overview of possible designs for polarizing both beams at the ILC, as well as for measuring their polarization.

  15. The Role of polarized positrons and electrons in revealing fundamental interactions at the linear collider

    Energy Technology Data Exchange (ETDEWEB)

    Moortgat-Pick, G.; /CERN /Durham U., IPPP; Abe, T.; Alexander, G.; Ananthanarayan, B.; Babich, A.A.; Bharadwaj, V.; Barber, D.; Bartl, A.; Brachmann, A.; Chen, S.; Clarke,; Clendenin, J.E.; Dainton, J.; Desch, K.; Diehl, M.; Dobos, B.; Dorland, T.; Eberl, H.; Ellis, John R.; Flottman, K.; Frass, H.; /CERN /Durham U., IPPP /Colorado U. /Tel-Aviv

    2005-07-01

    The proposed International Linear Collider (ILC) is well-suited for discovering physics beyond the Standard Model and for precisely unraveling the structure of the underlying physics. The physics return can be maximized by the use of polarized beams. This report shows the paramount role of polarized beams and summarizes the benefits obtained from polarizing the positron beam, as well as the electron beam. The physics case for this option is illustrated explicitly by analyzing reference reactions in different physics scenarios. The results show that positron polarization, combined with the clean experimental environment provided by the linear collider, allows to improve strongly the potential of searches for new particles and the identification of their dynamics, which opens the road to resolve shortcomings of the Standard Model. The report also presents an overview of possible designs for polarizing both beams at the ILC, as well as for measuring their polarization.

  16. Proceedings of the specialist meeting on positron annihilation study for science and engineering 2011

    International Nuclear Information System (INIS)

    Shirai, Yasuharu; Yoshiie, Toshimasa

    2012-01-01

    The utilization of positron beams in the field of materials science and engineering has increased remarkably in these years. It is meaningful for researches working in this field to gather together to promote and exchange views and information between them. For this purpose, the Specialist Research Meeting on Positron Beam Techniques for Science and Engineering was held on December 2nd and 3rd, 2011 at the Research Reactor Institute, Kyoto University. 66 participants jointed the Meeting and 28 papers were presented. This volume contains the summary and selected transparencies presented in the meeting. (J.P.N.)

  17. Low-energy positron and electron diffraction and positron-stimulated secondary electron emission from Cu(100)

    International Nuclear Information System (INIS)

    Weiss, A.H.

    1983-01-01

    The results of two series of experiments are reported. In the first, an electrostatically guided beam of low-energy (40-400 eV) positrons, delta/sub p/ was used to study low-energy positron diffraction (LEPD) from a Cu(100) surface under ultrahigh-vacuum conditions. Low-energy electron diffraction (LEED) data were obtained from the same sample in the same apparatus. Comparison of LEPD and LEED intensity versus energy data with model calculations made using computer programs developed by C.B. Duke and collaborators indicated that: LEPD data is adequately modeled using potentials with no exchange-correlation term. The inelastic mean free path, lambda/sub ee/, is shorter for positrons than for electrons at low (< approx.80 eV). LEED is better than LEPD at making a determination of the first-layer spacing of Cu(100) for the particular data set reported. In the second set of experiments, the same apparatus and sample were used to compare positron- and electron-stimulated secondary-electron emission (PSSEE and ESSEE). The results were found to be consistent with existing models of secondary-electron production for metals. The energy distributions of secondary-electrons had broad low-energy (<10 eV) peaks for both positron and electron stimulation. But the PSEE distribution showed no elastic peak. Measurements of secondary-electron angular distributions, found to be cosine-like in both the PSSEE and ESSEE case, were used to obtain total secondary yield ratios, delta, at four beam energies ranging from 40-400 eV. The secondary yield ratio for primary positrons and the yield for primary electrons, delta/sub e/, were similar at these energies. For 400-eV primary particles the secondary yields were found to be delta/sub p/ = 0.94 +/- 0.12 and delta/sub e/ = 0.94 +/- 0./12, giving a ratio of unity for positron-stimulated secondary yield to electron-stimulated secondary yield

  18. Electromagnetic cascade in high-energy electron, positron, and photon interactions with intense laser pulses

    Science.gov (United States)

    Bulanov, S. S.; Schroeder, C. B.; Esarey, E.; Leemans, W. P.

    2013-06-01

    The interaction of high-energy electrons, positrons, and photons with intense laser pulses is studied in head-on collision geometry. It is shown that electrons and/or positrons undergo a cascade-type process involving multiple emissions of photons. These photons can consequently convert into electron-positron pairs. As a result charged particles quickly lose their energy developing an exponentially decaying energy distribution, which suppresses the emission of high-energy photons, thus reducing the number of electron-positron pairs being generated. Therefore, this type of interaction suppresses the development of the electromagnetic avalanche-type discharge, i.e., the exponential growth of the number of electrons, positrons, and photons does not occur in the course of interaction. The suppression will occur when three-dimensional effects can be neglected in the transverse particle orbits, i.e., for sufficiently broad laser pulses with intensities that are not too extreme. The final distributions of electrons, positrons, and photons are calculated for the case of a high-energy e-beam interacting with a counterstreaming, short intense laser pulse. The energy loss of the e-beam, which requires a self-consistent quantum description, plays an important role in this process, as well as provides a clear experimental observable for the transition from the classical to quantum regime of interaction.

  19. Positron annihilation and transmission electron microscopy study of the evolution of microstructure in cold-rolled and nitrided FeNiTi foils

    NARCIS (Netherlands)

    Chechenin, N.G.; Veen, A. van; Escobar Galindo, R.; Schut, H.; Chezan, A.R.; Bronsveld, P.M.; Hosson, J.Th.M. de; Boerma, D.O.

    2001-01-01

    Positron beam analysis (PBA) and transmission electron microscopy (TEM) were applied to study structural transformations in cold-rolled Fe0.94Ni0.04Ti0.02 foils, which were subjected to different thermal treatments in an atmosphere of a gas mixture of NH3 + H2 (nitriding). Positrons proved to be

  20. Systematics of spontaneous positron lines

    International Nuclear Information System (INIS)

    Mueller, U.; Reus, T. de; Reinhardt, J.; Mueller, B.; Greiner, W.

    1985-08-01

    Dynamical and spontaneous positron emission are investigated for heavy-ion collisions with long time delay using a semiclassical description. Numerical results and analytical expressions for the characteristic quantities of the resulting spontaneous positron line, i.e., its position, width, and cross section, are compared. The expected behaviour of the line position and cross section and its visibility against the spectrum of dynamically created positrons is discussed in dependence of the united charge Zsub(u) of projectile and target nucleus in a range of systems from Zsub(u)=180 up to Zsub(u)=188. The results are confronted with presently available experimental data, and possible implications on further experiments are worked out. (orig.)

  1. Positron emitter labeled enzyme inhibitors

    International Nuclear Information System (INIS)

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-01-01

    This invention involves a new strategy for imagining and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography

  2. A study of energy correction for the electron beam data in the BGO ECAL of the DAMPE

    CERN Document Server

    Li, Zhiying; Wei, Yifeng; Wang, Chi; Zhang, Yunlong; Wen, Sicheng; Wang, Xiaolian; Xu, Zizong; Huang, Guangshun

    2015-01-01

    The DArk Matter Particle Explorer (DAMPE) is an orbital experiment aiming at searching for dark matter indirectly by measuring the spectra of photons, electrons and positrons originating from deep space. The BGO electromagnetic calorimeter is one of the key sub-detectors of the DAMPE, which is designed for high energy measurement with a large dynamic range from 5 GeV to 10 TeV. In this paper, some methods for energy correction are discussed and tried, in order to reconstruct the primary energy of the incident electrons. Different methods are chosen for the appropriate energy ranges. The results of Geant4 simulation and beam test data (at CERN) are presented.

  3. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  4. Positron spectra from internal pair conversion observed in 238U + 181Ta collisions

    CERN Document Server

    Heinz, S.; Heine, F.; Joeres, O.; Kienle, P.; Konig, I.; Konig, W.; Kozhuharov, C.; Leinberger, U.; Rhein, M.; Schroter, A.; Tsertos, Haralabos

    2000-01-01

    We present new results from measurements and simulations of positron spectra, originating from 238U + 181Ta collisions at beam energies close to the Coulomb barrier. The measurements were performed using an improved experimental setup at the double-Orange spectrometer of GSI. Particular emphasis is put on the signature of positrons from Internal-Pair-Conversion (IPC) processes in the measured e+ energy spectra, following the de-excitation of electromagnetic transitions in the moving Ta-like nucleus. It is shown by Monte Carlo simulations that, for the chosen current sweeping procedure used in the present experiments, positron emission from discrete IPC transitions can lead to rather narrow line structures in the measured energy spectra. The measured positron spectra do not show evidence for line structures within the statistical accuracy achieved, although expected from the intensities of the observed $\\gamma$ transitions (E$_{\\gamma}~1250-1600$ keV) and theoretical conversion coefficients. This is due to the...

  5. Studies of positron induced luminescence from polymers

    International Nuclear Information System (INIS)

    Xu, J.; Hulett, L.D. Jr.; Lewis, T.A.; Tolk, N.H.

    1994-01-01

    Light emission from polymers (anthracene dissolved in polystryrene) induced by low-energy positrons and electrons has been studied. Results indicate a clear difference between optical emissions under positron and electron bombardment. The positron-induced luminescence spectrum is believed to be generated by both collisional and annihilation processes

  6. Positron Spectroscopy of Hydrothermally Grown Actinide Oxides

    Science.gov (United States)

    2014-03-27

    POSITRON SPECTROSCOPY OF HYDROTHERMALLY GROWN ACTINIDE OXIDES THESIS Edward C. Schneider...United States Government. AFIT-ENP-14-M-33 POSITRON SPECTROSCOPY OF HYDROTHERMALLY GROWN ACTINIDE OXIDES THESIS...33 POSITRON SPECTROSCOPY OF HYDROTHERMALLY GROWN ACTINIDE OXIDES Edward C. Schneider, BS Captain, USAF Approved

  7. Study on low-energy positron polarimetry

    Indian Academy of Sciences (India)

    degree of polarisation close to the positron creation point is desired. In this contribution, methods for ... The spin is transferred to the pair-produced electrons and positrons. The positrons are captured right behind .... to be separated from Mott scattering and annihilation in flight processes. Analysing only final-state electrons ...

  8. Development and Testing of the Positron Identification By Coincident Annihilation Photons (PICAP) System

    Science.gov (United States)

    Tran, D.; Connell, J. J.; Lopate, C.; Bickford, B.

    2014-12-01

    Moderate energy positrons (~few to 10 MeV) have seldom been observed in the Heliosphere, due primarily to there not having been dedicated instruments for such measurements. Their detection would have implications in the study of Solar energetic particle events and the transport and modulation of the Solar wind and Galactic cosmic rays. The Positron Identification by Coincident Annihilation Photons (PICAP) system is designed specifically to measure these moderate energy positrons by simultaneously detecting the two 511-keV γ-ray photons that result from a positron stopping in the instrument and the subsequent electron-positron annihilation. This method is also expected to effectively discriminate positrons from protons by measuring the amount of energy deposited in the detectors (dE/dx versus residual energy). PICAP offers a low-mass, low-power option for measuring positrons, electrons, and ions in space. Following Monte Carlo modeling, a PICAP laboratory prototype, adaptable to a space-flight design, was designed, built, and tested. This instrument is comprised of (Si) solid-state detectors, plastic scintillation detectors, and high-Z BGO crystal scintillator suitable for detecting the 511-keV γ rays. The prototype underwent preliminary laboratory testing and calibration using radioactive sources for the purpose of establishing functionality. It has since been exposed to beams of energetic protons (up to ~200 MeV) at Massachusetts General Hospital's Francis H. Burr Proton Beam Therapy Center and positrons and electrons (up to ~10 MeV) at Idaho State University's Idaho Accelerator Center. The goal is to validate modeling and determine the performance of the instrument concept. We will present a summary of modeling calculations and analysis of data taken at the accelerator tests. This work is 95% supported by NASA Grant NNX10AC10G.

  9. WORKSHOP: Electron-positron mystery

    International Nuclear Information System (INIS)

    Bokemeyer, H.; Mueller, B.

    1989-01-01

    The tightly correlated electron-positron pairs seen in experiments at the GSI Darmstadt heavy ion Laboratory and elsewhere have yet to be explained. New particle or new effect? The question was highlighted at a recent Moriond workshop held at Les Arcs in the French Alps in January

  10. Study of Coherent Tune Shift Caused by Electron Cloud in Positron Storage Rings

    Energy Technology Data Exchange (ETDEWEB)

    Heifets, Samuel A

    2001-12-06

    We discuss the transverse betatron tune shift of the coherent dipole motion of a beam interacting with an electron cloud. A positron beam which passes through a frozen charge distribution experiences an electric field, which shifts its tune in the positive direction. The electrons in the actual cloud are not frozen, but move during the bunch passage. Thus, the electron distribution varies due to the interaction with the beam and it is ''soft''. We study the dipole tune shift of the beam interacting with such a ''soft'' charge distribution.

  11. Study of coherent tune shift caused by electron cloud in positron storage rings

    CERN Document Server

    Ohmi, K; Zimmermann, Frank

    2001-01-01

    We discuss the transverse betatron tune shift of the coherent dipole motion of a beam interacting with an electron cloud. A positron beam which passes through a frozen charge distribution experiences an electric field, which shifts its tune in the positive direction. The electrons in the actual cloud are not frozen, but move during the bunch passage. Thus, the electron distribution varies due to the interaction with the beam and it is "soft". We study the dipole tune shift of the beam interacting with such a "soft" charge distribution.

  12. Studies of Positron Generation from Ultraintense Laser-Matter Interactions

    Science.gov (United States)

    Williams, Gerald Jackson

    Laser-produced pair jets possess unique characteristics that offer great potential for their use in laboratory-astrophysics experiments to study energetic phenomenon such as relativistic shock accelerations. High-flux, high-energy positron sources may also be used to study relativistic pair plasmas and useful as novel diagnostic tools for high energy density conditions. Copious amounts of positrons are produced with MeV energies from directly irradiating targets with ultraintense lasers where relativistic electrons, accelerated by the laser field, drive positron-electron pair production. Alternatively, laser wakefield accelerated electrons can produce pairs by the same mechanisms inside a secondary converter target. This dissertation describes a series of novel experiments that investigate the characteristics and scaling of pair production from ultraintense lasers, which are designed to establish a robust platform for laboratory-based relativistic pair plasmas. Results include a simple power-law scaling to estimate the effective positron yield for elemental targets for any Maxwellian electron source, typical of direct laser-target interactions. To facilitate these measurements, a solenoid electromagnetic coil was constructed to focus emitted particles, increasing the effective collection angle of the detector and enabling the investigation of pair production from thin targets and low-Z materials. Laser wakefield electron sources were also explored as a compact, high repetition rate platform for the production of high energy pairs with potential applications to the creation of charge-neutral relativistic pair plasmas. Plasma accelerators can produce low-divergence electron beams with energies approaching a GeV at Hz frequencies. It was found that, even for high-energy positrons, energy loss and scattering mechanisms in the target create a fundamental limit to the divergence and energy spectrum of the emitted positrons. The potential future application of laser

  13. Investigation of focusing of relativistic electron and positron bunches moving in cold plasma. Final report

    International Nuclear Information System (INIS)

    Amatuni, A.Ts.; Elbakian, S.S.; Khachatryan, A.G.; Sekhpossian, E.V.

    1995-03-01

    This document is the final report on a project to study focusing effects of relativistic beams of electrons and positrons interacting with a cold plasma. The authors consider three different models for the overdense cold plasma - electron bunch interaction. They look at coulomb effects, wakefield effects, bunch parameters, and the effects of trains of pulses on focusing properties

  14. Design of a Polarised Positron Source Based on Laser Compton Scattering

    CERN Document Server

    Araki, S; Honda, Y; Kurihara, Y; Kuriki, M; Okugi, T; Omori, T; Taniguchi, T; Terunuma, N; Urakawa, J; Artru, X; Chevallier, M; Strakhovenko, V M; Bulyak, E; Gladkikh, P; Mönig, K; Chehab, R; Variola, A; Zomer, F; Guiducci, S; Raimondi, Pantaleo; Zimmermann, Frank; Sakaue, K; Hirose, T; Washio, M; Sasao, N; Yokoyama, H; Fukuda, M; Hirano, K; Takano, M; Takahashi, T; Sato, H; Tsunemi, A; Gao, J; Soskov, V

    2005-01-01

    We describe a scheme for producing polarised positrons at the ILC from polarised X-rays created by Compton scattering of a few-GeV electron beam off a CO2 or YAG laser. This scheme is very energy effective using high finesse laser cavities in conjunction with an electron storage ring.

  15. Positron annihilation in transparent ceramics

    International Nuclear Information System (INIS)

    Husband, P; Selim, F A; Bartošová, I; Slugeň, V

    2016-01-01

    Transparent ceramics are emerging as excellent candidates for many photonic applications including laser, scintillation and illumination. However achieving perfect transparency is essential in these applications and requires high technology processing and complete understanding for the ceramic microstructure and its effect on the optical properties. Positron annihilation spectroscopy (PAS) is the perfect tool to study porosity and defects. It has been applied to investigate many ceramic structures; and transparent ceramics field may be greatly advanced by applying PAS. In this work positron lifetime (PLT) measurements were carried out in parallel with optical studies on yttrium aluminum garnet transparent ceramics in order to gain an understanding for their structure at the atomic level and its effect on the transparency and light scattering. The study confirmed that PAS can provide useful information on their microstructure and guide the technology of manufacturing and advancing transparent ceramics. (paper)

  16. PEBS - Positron Electron Balloon Spectrometer

    CERN Document Server

    von Doetinchem, P.; Kirn, T.; Yearwood, G.Roper; Schael, S.

    2007-01-01

    The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was needed to design a detector which could increase the existing data by more than a factor of 100. Using silicon photomultipliers for the readout of a scintillating fiber tracker and of an imaging electromagnetic calorimeter, the PEBS detector features a large geometrical acceptance of 2500 cm^2 sr for positrons, a total weight of 1500 kg and a power consumption of 600 W. The experiment is intended to measure cosmic ray particle spectra for a period of up to 20 days at an altitude of 40 km circulating the North or South Pole. A full Geant 4 simulation of the detector concept has been developed and key elements have been verified in a testbeam in October 2006 at CERN.

  17. Positron-atom dispersion relations

    International Nuclear Information System (INIS)

    Dumbrajs, O.; Martinis, M.

    1983-01-01

    The singularity structure of the forward positron-atom scattering amplitude is studied within the framework of perturbation theory with the use of the Landau rules. The unphysical and anomalous regions in the positron-atom forward dispersion relations are discussed. It is shown that the unphysical region starts at E 0 = -Vertical BarE(Ps)Vertical Bar+Vertical BarE 1 Vertical Bar and the anomalous region at E/sub a/ = -(√2Vertical BarE(Ps)Vertical Bar - √Vertical BarE 1 Vertical Bar ) 2 , where E(Ps) and E 1 are correspondingly the positronium and the atomic-electron binding energies. The anomalous region is on the physical sheet if Vertical BarE(Ps)Vertical Bar/2>Vertical BarE 1 Vertical Bar

  18. Positrons in biomolecular systems. II

    International Nuclear Information System (INIS)

    Glass, J.C.; Graf, G.; Costabal, H.; Ewert, D.H.; English, L.

    1982-01-01

    Pickoff-annihilation parameters, as related to the free volume model, are shown to be indicators of structural fluctuations in membranes and membrane bound proteins. Nitrous oxide anesthetic induces lateral rigidity in a membrane, and an anesthetic mechanism is suggested. Conformational changes of (Na + ,K + )ATPase in natural membrane are observed with ATP and Mg-ion binding. New positron applications to active transport and photosynthetic systems are suggested. (Auth.)

  19. Research of the internal electron-positron pair production

    International Nuclear Information System (INIS)

    Fenyes, Tibor

    1985-01-01

    The phenomenon of internal electron-positron pair production by excited nuclei is briefly reviewed. The advantages of this phenomenon in nuclear structure investigations are pointed. The new Si(Li)-Si(Li) electron spectrometer with superconducting magnetic transporter (SMS) built at ATOMKI, Hungary, was tested for detection of internal electron-positron pair production events. Proton beam of a Van de Graaff accelerator of 5 MV was used to excite the target nuclei of sup(27)Al, sup(42)Ca and sup(19)F. The internal pair production coefficients were measured and compared with the data of literature. The detection efficiency of SMS is calculated to be (37+-7)%. The test proved that the SMS is suitable for nuclear structure investigations producing electron-positron pairs. The SMS of ATOMKI is recently the top instrument all over the world in this field: its detection efficiency, energy resolution and applicability for multipolarity identification are much better than these properties of other detectors. (D.Gy.)

  20. Production of muon pairs in the continuum region by 39.5 GeV/c π+-, K+-, p and anti p beams incident on a copper target

    International Nuclear Information System (INIS)

    Corden, M.J.; Dowell, J.D.; Eastwood, D.; Garvey, J.; Homer, R.J.; Jobes, M.; Kenyon, I.R.; McMahon, T.J.; Vallance, R.J.; Watkins, P.M.; Wilson, J.A.; Gago, J.; Jung, M.; Sonderegger, P.; Treille, D.; Woodworth, P.L.; Eckardt, V.; Fent, J.; Pretzl, K.; Seyboth, P.; Seyerlein, J.; Perrin, D.; Sumorok, K.C.T.O.

    1978-01-01

    General features of the inclusive hadroproduction of muon pairs of mass greater than 1.5 GeV/c 2 are shown. For incident π - , the data extend up to M = 5.7 GeV/c 2 (i.e. M 2 /s approximately 0.4). The scaling cross section M 3 dsigma/dM for π - N reaction is much flatter than that for pN reactions and exceeds the latter by two to three orders of magnitude at large M 2 /s. (Auth.)

  1. Evidence for evanescent waves at interfaces in a high-index prism/liquid-crystal-Au-NPs/glass/air structure and effects of relative concentration of gold nanoparticles, wavelength, polarization, and incident angle of the laser beam

    Science.gov (United States)

    Tiwari, Kunal; Singh, Ankit; Sharma, Suresh

    2011-10-01

    Incorporation of relatively small concentrations of gold nanoparticles (Au NPs) in a polymer-dispersed liquid crystal (PDLC) is known to lower the operating threshold voltage and increase optical transmission through the device.ootnotetextA. Hinojosa and S. C. Sharma, Applied Physics Letters, 97, 081114 (2010) In order to understand whether there is an interplay between the localized surface plasmon resonance at Au-NPs-dielectric interfaces and the electro-optical properties of PDLC devices, we have investigated propagation of light through a high-index prism/liquid-crystal-Au-NPs/glass/air structure by using Kretschmann geometry as functions of concentration of Au NPs in the liquid crystal, and the wavelength, polarization, and angle of incidence of the laser beam. We will discuss to what extent the results of these experiments support an interplay between the localized surface plasmon resonance at NPs/dielectric interfaces and optical propagation through the above-described structure.

  2. Focusing an antimatter beam with matter

    CERN Document Server

    CERN. Geneva

    2000-01-01

    An experiment at the Stanford Linear Accelerator Center has recently focused positron beams by means of a plasma lens. This is the first time this process has been observed. The process started with a positron beam from the SLAC PEP-II positron source. This was sent through a damping ring and then accelerated to 28.5 GeV in the SLAC linac with a bunch intensity of 1-2*10/sup 10/. The beam was delivered to the Final Focus Test Beam Facility (FFTB) at a rate of 1 or 10 Hz. At the focal point of the FFTB transport, a special plasma chamber contains a 3 mm diameter pulsed gas nozzle through which either hydrogen or nitrogen gas is "puffed" into the ultrahigh vacuum system at plenum gas pressures up to 75 atm with a discharge time of 800 mu s. The gas is pumped off by a Roots-type pump. On either side of the central chamber are differential pumping sections semi- isolated from each other by thin titanium windows with small (2-5 mm diameter) apertures for the positron beams to pass through. These sections are evacu...

  3. Positron annihilation in the interstellar medium

    Science.gov (United States)

    Guessoum, Nidhal; Ramaty, Reuven; Lingenfelter, Richard E.

    1991-01-01

    Positronium formation and annihilation are studied in a model for the interstellar medium consisting of cold cloud cores, warm partially ionized cloud envelopes, and hot intercloud gas. The gamma-ray spectra resulting from positron annihilation in these components of the interstellar medium are calculated. The spectra from the individual components are then combined, using two limiting assumptions for the propagation of the positrons, namely, that the positrons propagate freely throughout the interstellar medium, and that the positrons are excluded from the cold cloud cores. In the first case, the bulk of the positrons annihilate in the cloud cores and the annihilation line exhibits broad wings resulting from the annihilation of positronium formed by charge exchange in flight. In the second case, the positrons annihilate mainly in the warm envelopes, and the line wings are suppressed.

  4. Multi-GeV electron-positron pair generation from laser-electron scattering

    Science.gov (United States)

    Vranic, Marija; Klimo, Ondrej; Korn, Georg; Weber, Stefan

    2017-10-01

    Positron generation in the laboratory is of great importance, both for fundamental science and potential applications. For laboratory astrophysics, it is particularly important to produce neutral electron-positron plasma, with properties that allow studying their collective behavior. Electron-positron pairs can be generated by first emitting an energetic photon, that later decays into a pair in an intense background field (Breit-Wheeler process). Recently, several experiments demonstrated that high-frequency radiation can be generated in laser-electron beam scattering. Here we propose a new scattering configuration that can both generate electron-positron pairs, and later accelerate them to multi-GeV energies. This configuration allows obtaining an e+e- flow with a higher energy than that of the initial electron beam. We develop an analytical model that predicts the energy cutoff. We discuss the number of pairs expected, the acceleration and the overall quality of the beam. We also study the role of pulse duration and spatiotemporal synchronization for the overall number of pairs. The work is supported by OSIRIS QED-PIC simulations, and these ideas can be tested with a new generation laser system at ELI Beamlines that will provide 10 PW peak power in a 150 fs pulse duration.

  5. The potential application of silver and positron emission tomography for in vivo dosimetry during radiotherapy

    DEFF Research Database (Denmark)

    Hansen, Anders T; Hansen, Søren B; Petersen, Jørgen B

    2007-01-01

    The possible use of silver as a material for in vivo dosimetry in radiotherapy was investigated. The investigation was carried out using a positron emission tomography (PET) scanner, two clinical accelerators and a phantom with silver implants. The phantom was irradiated several times to doses...... between 6 and 45 Gy. The resulting activity of positron-emitting isotopes produced in the silver by photonuclear processes was measured. It was found that the two therapeutic beams with energies of 15 MV and 18 MV would produce approximately 8344 and 7013 atoms of the radioactive isotope (106)Ag per Gy...

  6. Construction and use of an intense positron source at new linac facilities in Germany. Conceptual report

    International Nuclear Information System (INIS)

    Brauer, G.

    2000-07-01

    In this conceptual report the idea to establish an European positron source for applied research (''EPOS'') based on new LINAC facilities in Germany (ELBE/Rossendorf or TTF-DESY/Hamburg) is considered. The report contains not only the outline of obvious applications in atomic physics, materials science and surface physics, but also several new methodical developments which are only possible with an intense positron beam. This opportunity will also allow the use and further development of imaging techniques being of special interest for industrial applications. (orig.)

  7. Total and ionization cross-sections of N2 and CO by positron impact ...

    Indian Academy of Sciences (India)

    Total and ionization cross-sections of N2 and CO different for different projectiles so that the total (complete) cross-sections QT exhibit a large difference at low energies for the e. − against e. + projectiles. The absorption potential Vabs(r, Ei) used presently to account for all inelastic channels with incident positrons was ...

  8. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  9. Solvated Positron Chemistry. The Reaction of Hydrated Positrons with Chloride Ions

    DEFF Research Database (Denmark)

    Mogensen, O. E.; Shantarovich, V. P.

    1974-01-01

    The reaction of hydrated positrons (caq+ with cloride ions in aqueous solutions has been studied by means of positron annihilation angular correlation measurements. A rate constant of k = (2.5 ± 0.5) × 1010 M−1 s−1 was found. Probably the reacting positrons annihilated from an e+ Cl− bound state...... resulting in an angular correlation curve 8% narrower than for the hydrated positron. Carbontetrachloride in benzene seems to give similar, but smaller effect....

  10. Energy transparency and symmetries in the beam-beam interaction

    Directory of Open Access Journals (Sweden)

    S. Krishnagopal

    2000-02-01

    Full Text Available We have modified the beam-beam simulation code CBI to handle asymmetric beams and used it to look at energy transparency and symmetries in the beam-beam interaction. We find that even a small violation of energy transparency, or of the symmetry between the two beams, changes the character of the collective (coherent motion; in particular, period-n oscillations are no longer seen. We speculate that the one-time observation of these oscillations at LEP, and the more ubiquitous observation of the flip-flop instability in colliders around the world, may be a consequence of breaking the symmetry between the electron and positron beams. We also apply this code to the asymmetric collider PEP-II, and find that for the nominal parameters of PEP-II, in particular, the nominal tune-shift parameter of ξ_{0}=0.03, there are no collective beam-beam issues. Collective quadrupole motion sets in only at ξ_{0}=0.06 and above, consistent with earlier observations for symmetric beams.

  11. Mode coupling and multiquantum vibrational excitations in Feshbach-resonant positron annihilation in molecules

    Science.gov (United States)

    Gribakin, G. F.; Stanton, J. F.; Danielson, J. R.; Natisin, M. R.; Surko, C. M.

    2017-12-01

    The dominant mechanism of low-energy positron annihilation in polyatomic molecules is through positron capture in vibrational Feshbach resonances (VFR). In this paper, we investigate theoretically the effect of anharmonic terms in the vibrational Hamiltonian on positron annihilation rates. Such interactions enable positron capture in VFRs associated with multiquantum vibrational excitations, leading to enhanced annihilation. Mode coupling can also lead to faster depopulation of VFRs, thereby reducing their contribution to the annihilation rates. To analyze this complex picture, we use coupled-cluster methods to calculate the anharmonic vibrational spectra and dipole transition amplitudes for chloroform, chloroform-d1, 1,1-dichloroethylene, and methanol, and use these data to compute positron resonant annihilation rates for these molecules. Theoretical predictions are compared with the annihilation rates measured as a function of incident positron energy. The results demonstrate the importance of mode coupling in both enhancement and suppression of the VFR. There is also experimental evidence for the direct excitation of multimode VFR. Their contribution is analyzed using a statistical approach, with an outlook towards more accurate treatment of this phenomenon.

  12. Survey of beam-beam limitations

    International Nuclear Information System (INIS)

    Courant, E.; Cornacchia, M.; Donald, M.M.R.; Evans, L.R.; Tazzari, S.; Wilson, E.J.N.

    1979-01-01

    The effect of beam-beam interaction is known to limit the luminosity of electron-positron storage rings and will, no doubt, limit the proton-antiproton collision scheme for the SPS. While theorists are struggling to explain this phenomenon it is more instructive to list their failures than their rather limited successes, in the hope that experiments may emerge which will direct their endeavors. The search for a description of a nonlinear system as it approaches the limit in which ordered motion breaks down, is the nub of the problem. It has engaged many fine mathematical intellects for decades and will no doubt continue to do so long after ISABELLE, the p antip and LEP are past achievements. Empirical scaling laws are emerging which relate electron machines to each other but their extrapolation to proton machines remain a very speculative exercise. Experimental data on proton limits is confined to one machine, the ISR, which does not normally suffer the beam-beam effect and where it must be artificially induced or simulated. This machine is also very different in important ways from the p antip collider. The gloomy picture which has emerged recently is that the fixed limits which were conventionally assumed for proton and electron machines can only be said to be valid for the machines which engendered them - the best guess that could be made at the time. They are very difficult to extrapolate to other sets of parameters

  13. Beam chopper development at LAMPF

    International Nuclear Information System (INIS)

    Hutson, R.L.; Cooke, D.W.; Heffner, R.H.; Schillaci, M.E.; Dodds, S.A.; Gist, G.A.

    1986-01-01

    In order to reduce pileup limitations on μSR data rates, a fast chopper for surface muon beams was built and tested at LAMPF. The system allowed one muon at a time to be stopped in a μSR sample in the following way: A surface beam from the LAMPF Stopped Muon Channel was focused through a crossed-field beam separator and onto a chopper slit. With the separator E and B fields adjusted properly, the beam could pass through the slit. The beam to the μSR sample was turned on or off (chopped) rapidly by switching the high voltage applied to the separator plates on or off within approximately 500 ns; with the E field off, the B field deflected the beam, dumping it near the slit. We demonstrated that, with improved electronics, we will be able to stop a single muon in a μSR sample as frequently as once every 20 μs and that data rates for the system can be a factor of five higher than is attainable with unchopped beams. The observed positron contamination of the beam was less than five percent, and the ratio of the muon rate with beam on to the rate with beam off was 1540

  14. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: a Monte Carlo study.

    Science.gov (United States)

    Manohar, Nivedh; Jones, Bernard L; Cho, Sang Hyun

    2014-10-01

    To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the investigated range of 81-100 ke

  15. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study

    Science.gov (United States)

    Manohar, Nivedh; Jones, Bernard L.; Cho, Sang Hyun

    2014-01-01

    Purpose: To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). Methods: A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Results: Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the

  16. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering...... is calculated from the NMF solution. The method is tested on a [18F]-Altanserin tracer ligand data set consisting of 5 healthy subjects. The results from using K-means clustering and NMF are compared to a sampled arterial TAC. The comparison is done by calculating the correlation with the arterial sampled TAC....

  17. Positron tomography. Methodology and applications

    International Nuclear Information System (INIS)

    Kellershohn, C.; Comar, D.

    1979-01-01

    Whereas single photon tomography provides a new and rewarding dimension to conventional nuclear medicine, positron tomography makes a new original approach possible of the analysis in vivo of fundamental biological and physiological processes. The main object of both is the sectional representation of the distribution of a radioactive indicator injected into the body system; compared with conventional detectors (gamma cameras and scintigraphic systems) they provide much greater accuracy in localization. The characteristics of these two methods can be presented schematically by comparing their respective advantages and drawbacks [fr

  18. Positron emission tomography takes lead

    International Nuclear Information System (INIS)

    Simms, R.

    1989-01-01

    Positron emission tomography (PET)'s ability to detect functional abnormalities before they manifest anatomically is examined and some of its most common applications are outlined. It is emphasised that when PET facility and Australian Nuclear Science and Technology Organization's national cyclotron are established at the Royal Prince Alfred Hospital, the availability of short-lived tracers such as oxygen 15, nitrogen 13 and fluorine 18 would improve the specificity of tests(e.g. for brain tumors or cardiac viability) further. Construction of the cyclotron will start shortly and is due to be completed and operating by the end of 1991

  19. Beam Profile Measurement in MTA Beam Line for High Pressure RF Cavity Beam Test

    International Nuclear Information System (INIS)

    Jana, M.R.; Bross, A.; Chung, M.; Greer, S.; Johnstone, C.; Kobilarcik, T.; Koizumi, G.; Leonova, M.; Moretti, A.; Popovic, M.; Schwartz, T.

    2012-01-01

    Recent High Pressure RF (HPRF) cavity experiment at MuCool Test Area (MTA) has used 400 MeV Linac proton beam to study the beam loading effect. When the energetic proton beam passes through the cavity, it ionizes the inside gas and produces the electrons. These electrons consume RF power inside the cavity. Number of electrons produced per cm inside the cavity (at 950 psi Hydrogen gas) per incident proton is ∼ 1200. The measurement of beam position and profile are necessary. MTA is flammable gas (Hydrogen) hazard zone so we have developed a passive beam diagnostic instrument using Chromox-6 scintillation screen and CCD camera. This paper presents quantitative information about beam position and beam profile. Neutral density filter was used to avoid saturation of CCD camera. Image data is filtered and fitted with Gaussian function to compute the beam size. The beam profile obtained from scintillation screen shall be compared with multi-wire beam profile.

  20. Ultrarelativistic electron beam spatial size estimation from angular distribution emission in thin crystals

    Energy Technology Data Exchange (ETDEWEB)

    Goponov, Yu.A.; Sidnin, M.A. [Belgorod National Research University, Belgorod (Russian Federation); Sumitani, K.; Takabayashi, Y. [SAGA Light Source, 8-7 Yayoigaoka, Tosu, Saga 841-0005 (Japan); Vnukov, I.E., E-mail: vnukov@bsu.edu.ru [Belgorod National Research University, Belgorod (Russian Federation)

    2016-02-01

    The use of ultrarelativistic electron (positron) emission in thin crystals to estimate particle beam spatial sizes for projected electron–positron colliders is proposed. The existing position-sensitive X-ray range detectors restrict the minimum value of the measured beam size to a level of approximately 10 μm, which is far greater than the planned sizes of collider beams. We propose to estimate the electron (positron) beam divergence over the diffracted transition radiation from angular distribution measurements. The spatial size can be obtained from the calculated beam emittance or the experimental emittance, which is measured during the earlier stage of acceleration using optical transition or optical diffraction radiation. The problem of crystal destruction under the influence of a high-intensity electron beam is discussed. The use of surface parametric X-ray radiation, where the problem of crystal destruction is almost absent, to measure the electron beam parameters is also discussed.

  1. Ultrarelativistic electron beam spatial size estimation from angular distribution emission in thin crystals

    Science.gov (United States)

    Goponov, Yu. A.; Sidnin, M. A.; Sumitani, K.; Takabayashi, Y.; Vnukov, I. E.

    2016-02-01

    The use of ultrarelativistic electron (positron) emission in thin crystals to estimate particle beam spatial sizes for projected electron-positron colliders is proposed. The existing position-sensitive X-ray range detectors restrict the minimum value of the measured beam size to a level of approximately 10 μm, which is far greater than the planned sizes of collider beams. We propose to estimate the electron (positron) beam divergence over the diffracted transition radiation from angular distribution measurements. The spatial size can be obtained from the calculated beam emittance or the experimental emittance, which is measured during the earlier stage of acceleration using optical transition or optical diffraction radiation. The problem of crystal destruction under the influence of a high-intensity electron beam is discussed. The use of surface parametric X-ray radiation, where the problem of crystal destruction is almost absent, to measure the electron beam parameters is also discussed.

  2. The annihilation of positrons in the cold phase of the interstellar medium revisited

    Science.gov (United States)

    Wallyn, P.; Durouchoux, PH.; Chapuis, C.; Leventhal, M.

    1994-01-01

    The positron cross sections in H and H2 media are reevaluated, taking into account new experimental results. Using a Monte Carlo simulation, we find a positronium fraction before thermalization of 0.90 for H2, in good agreement with the previous experimental result given by Brown et al. (1986). For H we obtain an upper limit of 0.98. We study the behavior of the charge exchange annihilation in a cold phase (molecular cloud). We calculate a formula for the slowing-down time t, before annihilation lasting Delta t, via charge exchange, of a positron beam with a given energy for different medium densities and initial energies. An upper limit of 0.7 MeV for the initial energy of the positrons, annihilating in the molecular cloud G0.86 - 0.08 near the gamma ray source positronium and gives new time constraints on their possible observation.

  3. Photon collider beam simulation with CAIN

    Indian Academy of Sciences (India)

    the laser pulse and the beam–beam interaction, is presented in figure 1. Energy flow obtained from the simulation was scaled to the average beam power. After the. Compton scattering, most of the incident electron beam power is transfered to the photon beam. However, the high-energy photons are very well-collimated ...

  4. ALICE Transition Radiation Detector (TRD), test beam.

    CERN Multimedia

    2003-01-01

    Electrons and positrons can be discriminated from other charged particles using the emission of transition radiation - X-rays emitted when the particles cross many layers of thin materials. To develop such a Transition Radiation Detector(TRD) for ALICE many detector prototypes were tested in mixed beams of pions and electrons, as in the example shown here.

  5. Positron Emission Mammotomography with Dual Planar Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mark Smith; Raymond Raylman; Stanislaw Majewski

    2003-06-29

    Positron emission mammography (PEM) is usually performed with two stationary planar detectors above and below a compressed breast. There is image blurring normal to the detectors due to the limited angular range of the lines of response. Positron emission mammotomography (PEM-T) with dual planar detectors rotating about the breast can obtain complete angular sampling and has the potential to improve activity estimation.

  6. Positrons trapped in polyethylene: Electric field effect

    International Nuclear Information System (INIS)

    Bertolaccini, M.; Bisi, A.; Gambarini, G.; Zappa, L.

    1978-01-01

    The intensity of the iot 2 -component of positrons annihilated in polyethylene is found to increase with increasing electric field, while the formation probability of the positron state responsible for this component remains independent of the field. (orig.) 891 HPOE [de

  7. Nondestructive examination using neutron activated positron annihilation

    Science.gov (United States)

    Akers, Douglas W.; Denison, Arthur B.

    2001-01-01

    A method is provided for performing nondestructive examination of a metal specimen using neutron activated positron annihilation wherein the positron emitter source is formed within the metal specimen. The method permits in situ nondestructive examination and has the advantage of being capable of performing bulk analysis to determine embrittlement, fatigue and dislocation within a metal specimen.

  8. Summary test results of the particle-beam diagnostics for the Advanced Photon Source (APS) subsystems

    International Nuclear Information System (INIS)

    Lumpkin, A.; Wang, X.; Sellyey, W.; Patterson, D.; Kahana, E.

    1994-01-01

    During the first half of 1994, a number of the diagnostic systems for measurement of the charged-particle beam parameters throughout the subsystems of the Advanced Photon Source (APS) have been installed and tested. The particle beams eventually will involve 450-MeV to 7-GeV positrons and with different pulse formats. The first test and commissionin results for beam profiles, beam position monitors, loss rate monitors, current monitors, and synchrotron radiation photon monitors hve been obtained using 200- to 350-MeV electron beams injected into the subsystems. Data presented are principally from the transport lines and the positron accumulator ring

  9. Applications for positron emission mammography.

    Science.gov (United States)

    Weinberg, Irving N

    2006-01-01

    High resolution positron emission mammography (PEM) can address the current clinical needs of breast cancer patients and the requirements for future translational work. Combining the quantitative capabilities of positron emission tomography (PET) with millimeter resolution, PEM can image the earliest in situ forms of breast cancer as well as putative cancer precursor lesions (e.g., atypical ductal hyperplasia) whose behavior is important for prevention studies. The importance of the ability to detect intraductal cancer cannot be overemphasized, for several reasons: at least one-third of new cancers are detected at this intraductal stage, intervention at this stage represents the best opportunity for complete cure, and a significant number of invasive cancers contain an intraductal component. Without knowledge of the extent of the intraductal component, surgeons are unable to completely excise cancers about a third of the time, leading to unnecessary re-excisions or radiation therapy. Current investigations aimed at specifying best practices in radiotherapy of DCIS patients are stymied by the lack of objective quantitative methods of rapidly assessing response. Other future applications of PEM are suggested, including an information technology project built on PEM that promises to individualize therapy and facilitate surveillance of high risk populations. The high overall accuracy of PEM (i.e., both specificity and sensitivity) is an unusual and welcome development in the history of breast imaging. With this high accuracy, and continued technical innovation to reduce radiation dose, PEM may someday replace X-ray mammography as a first line approach to breast cancer detection.

  10. Positronic complexes with unnatural parity

    International Nuclear Information System (INIS)

    Bromley, M. W. J.; Mitroy, J.; Varga, K.

    2007-01-01

    The structure of the unnatural parity states of PsH, LiPs, NaPs, and KPs are investigated with the configuration interaction and stochastic variational methods. The binding energies (in hartree) are found to be 8.17x10 -4 , 4.42x10 -4 , 15.14x10 -4 , and 21.80x10 -4 , respectively. These states are constructed by first coupling the two electrons into a configuration which is predominantly 3 P e , and then adding a p-wave positron. All the active particles are in states in which the relative angular momentum between any pair of particles is at least L=1. The LiPs state is Borromean since there are no three-body bound subsystems (of the correct symmetry) of the (Li + , e - , e - , e + ) particles that make up the system. The dominant decay mode of these states will be radiative decay into a configuration that autoionizes or undergoes positron annihilation

  11. Characterization of vacancy type defects in Electronic Materials by Positron Lifetime and Age-Momentum Correlation Spectroscopy

    Science.gov (United States)

    Suzuki, Ryoichi; Ohdaira, Toshiyuki

    2002-03-01

    Positron annihilation spectroscopy is known to be sensitive to vacancy type defects. At the National Institute of Advanced Industrial Science and Technology (AIST) Japan, the authors have developed a measurement system which enables us to perform depth-selective positron annihilation lifetime spectroscopy (PALS) and positron age-momentum correlation (AMOC) spectroscopy with an intense slow positron beam. PALS gives us information on the size of vacancies whereas AMOC gives us information on not only vacancy sizes but also impurities or chemical environments. Using this system, we have carried out defect characterization experiments on various electronic materials, e.g. ion implanted Si, SiO2/Si, MOS, CVD or SOD (spin-on-dielectric) grown low dielectric insulator films, etc.

  12. GPDs and DVCS with Positrons

    Energy Technology Data Exchange (ETDEWEB)

    Matthias Burkardt

    2009-09-01

    The beam charge asymmetry helps to isolate the real part of the deeply virtual Compton scattering (DVCS) amplitude. It is discussed what information can be gained both from the real and imaginary part of the DVCS amplitude.

  13. Controlling Second Harmonic Efficiency of Laser Beam Interactions

    Science.gov (United States)

    Barnes, Norman P. (Inventor); Walsh, Brian M. (Inventor); Reichle, Donald J. (Inventor)

    2011-01-01

    A method is provided for controlling second harmonic efficiency of laser beam interactions. A laser system generates two laser beams (e.g., a laser beam with two polarizations) for incidence on a nonlinear crystal having a preferred direction of propagation. Prior to incidence on the crystal, the beams are optically processed based on the crystal's beam separation characteristics to thereby control a position in the crystal along the preferred direction of propagation at which the beams interact.

  14. Beam scrubbing of beam pipes during the first commissioning of SuperKEKB

    Science.gov (United States)

    Suetsugu, Y.; Shibata, K.; Ishibashi, T.; Kanazawa, K.; Shirai, M.; Terui, S.; Hisamatsu, H.

    2018-02-01

    The first (Phase-1) commissioning of SuperKEKB-an electron-positron collider with asymmetric energies located at KEK, in Tsukuba, Japan-started in February 2016, after more than five years of upgrading work on KEKB, and successfully ended in June of the same year. This paper describes one major task of Phase-1 commissioning: beam scrubbing the surface of the beam pipes, to prepare them for a sufficiently long beam lifetime and low background noise in the next commissioning, when a new particle detector will be installed. The pressure rises per unit beam current (dP/dI [Pa A-1]) were continuously monitored, and the coefficient of photon-stimulated desorption (PSD), η [molecules photon-1], was evaluated in the arc sections. The value of η decreased steadily with the beam dose, as expected. For arc sections in the positron ring, where most of the beam pipes were newly fabricated, the decrease in η against the photon dose (D) was similar to that previously reported; that is: η ∝ D-0.5 ∼ 0.8. At high storage beam currents, the evolution of η was affected by gas desorption resulting from the multipacting of electrons-that is, the electron cloud effect (ECE), which is a phenomenon particular to high-intensity positron rings. For the arc sections in the electron ring, η also decreased smoothly with the photon dose D, approximately as ∝ D-0.8. Given that most of these beam pipes were reused from KEKB, the value of η was much lower than that of the positron ring, and also lower than that of the electron ring of KEKB from the early stages of D. This implies that the surface of the reused beam pipes remembered the conditions in the KEKB, which is a known memory effect. The results obtained for η are compared with those obtained in various other accelerators.

  15. Characterizing free volumes and layer structures in polymeric membranes using slow positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Jean, Y C; Chen Hongmin; Awad, Somia; Zhang Sui; Chen Hangzheng; Lau, Cher Hon; Wang Huan; Li Fuyun; Chung, Tai-Shung; Lee, L James; Huang, James

    2011-01-01

    Positron annihilation spectroscopy coupled with a newly built slow positron beam at National University of Singapore has been used to study the free volume, pore, and depth profile (0 - 10 μm) in cellulose acetate polymeric membrane at the bottom and top sides of membranes for ionic separation in water purification applications. The S and R parameters from Doppler broadening energy of annihilation radiation representing free volumes (0.1-1 nm size) and pores (>1 nm-μm) as a function of depth have been analyzed into multilayers, i.e. skin dense, transition, and porous layers, respectively. The top side of membrane has large free volumes and pores and the bottom side has a skin dense layer, which plays a key role in membrane performance. Positron annihilation lifetime results provide additional information about free-volume size and distribution at the atomic and molecular scale in polymeric membrane systems. Doppler broadening energy and lifetime spectroscopies coupled with a variable mono-energy slow positron beam are sensitive and novel techniques for characterization of polymeric membrane in separation applications.

  16. Vacancy profile in reverse osmosis membranes studied by positron annihilation lifetime measurements and molecular dynamics simulations

    International Nuclear Information System (INIS)

    Shimazu, A; Shintani, T; Hirose, M; Goto, H; Suzuki, R; Kobayashi, Y

    2013-01-01

    The positron annihilation technique using a slow positron beam can be used for the study of the vacancy profiles in typical reverse osmosis (RO) membranes. In this study, the vacancy profile in the polyamide membrane that exhibits a high permselectivity between ions and water was studied using the positron annihilation technique and molecular dynamics simulations. Ortho-positronium (o-Ps) lifetimes in the surface region of the membranes were evaluated by using a slow positron beam. The diffusion behavior of Na + and water in the polyamides was simulated by molecular dynamics (MD) methods using the TSUBAME2 supercomputer at the Tokyo Institute of Technology and discussed with the vacancy profile probed by the o-Ps. The results suggested that the large hydration size of Na + compared to the vacancy size in the polyamides contributes to the increased diffusivity selectivity of water/Na + that is related to the NaCl desalination performance of the membrane. Both the hydration size of the ions and the vacancy size appeared to be significant parameters to discuss the diffusivity selectivity of water/ions in typical polyamide membranes.

  17. Design of kicker magnet and power supply unit for synchrotron beam injection

    International Nuclear Information System (INIS)

    Wang, Ju.

    1991-03-01

    To inject beams from the positron accumulator ring (PAR) into the synchrotron, a pulsed kicker magnet is used. The specifications of this kicker magnet and the power supply unit are listed and discussed in this report

  18. Positron emission tomography and migraine

    International Nuclear Information System (INIS)

    Chabriat, H.

    1992-01-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT 2 serotonin receptors can be studied in migraine patients with PET

  19. Positron emission tomography basic sciences

    CERN Document Server

    Townsend, D W; Valk, P E; Maisey, M N

    2003-01-01

    Essential for students, science and medical graduates who want to understand the basic science of Positron Emission Tomography (PET), this book describes the physics, chemistry, technology and overview of the clinical uses behind the science of PET and the imaging techniques it uses. In recent years, PET has moved from high-end research imaging tool used by the highly specialized to an essential component of clinical evaluation in the clinic, especially in cancer management. Previously being the realm of scientists, this book explains PET instrumentation, radiochemistry, PET data acquisition and image formation, integration of structural and functional images, radiation dosimetry and protection, and applications in dedicated areas such as drug development, oncology, and gene expression imaging. The technologist, the science, engineering or chemistry graduate seeking further detailed information about PET, or the medical advanced trainee wishing to gain insight into the basic science of PET will find this book...

  20. Scintillators for positron emission tomography

    International Nuclear Information System (INIS)

    Moses, W.W.; Derenzo, S.E.

    1995-09-01

    Like most applications that utilize scintillators for gamma detection, Positron Emission Tomography (PET) desires materials with high light output, short decay time, and excellent stopping power that are also inexpensive, mechanically rugged, and chemically inert. Realizing that this ''ultimate'' scintillator may not exist, this paper evaluates the relative importance of these qualities and describes their impact on the imaging performance of PET. The most important PET scintillator quality is the ability to absorb 511 keV photons in a small volume, which affects the spatial resolution of the camera. The dominant factor is a short attenuation length (≤ 1.5 cm is required), although a high photoelectric fraction is also important (> 30% is desired). The next most important quality is a short decay time, which affects both the dead time and the coincidence timing resolution. Detection rates for single 511 keV photons can be extremely high, so decay times ≤ 500 ns are essential to avoid dead time losses. In addition, positron annihilations are identified by time coincidence so ≤5 ns fwhm coincidence pair timing resolution is required to identify events with narrow coincidence windows, reducing contamination due to accidental coincidences. Current trends in PET cameras are toward septaless, ''fully-3D'' cameras, which have significantly higher count rates than conventional 2-D cameras and so place higher demands on scintillator decay time. Light output affects energy resolution, and thus the ability of the camera to identify and reject events where the initial 511 keV photon has undergone Compton scatter in the patient. The scatter to true event fraction is much higher in fully-3D cameras than in 2-D cameras, so future PET cameras would benefit from scintillators with a 511 keV energy resolution < 10--12% fwhm

  1. The Intense Slow Positron Source concept: A theoretical perspective on a proposed INEL Facility

    International Nuclear Information System (INIS)

    Makowitz, H.; Abrashoff, J.D.; Landman, W.H.; Albano, R.K.; Tajima, T.

    1992-01-01

    An analysis has been performed of the INEL Intense Slow Positron Source (ISPS) concept. The results of the theoretical study are encouraging. A full-scale device with a monoenergetic 5 KeV positron beam of ≥10 12 e + /s on a ≤0.03-cmdiameter target appears feasible and can be obtained within the existing infrastructure of INEL reactor facilities. A 30.0-cm-diameter, large area source dish, moderated at first with thin crystalline W films and later by solid Ne, is proposed as the initial device in order to explore problems with a facility scale system. A demonstration scale beam at ≥10 10 slow e + /s is proposed using a 58 Co source plated on a 6-cm-diameter source dish insert, placed in a 30- cm adapter

  2. Positron emission tomography studies of brain receptors

    International Nuclear Information System (INIS)

    Maziere, B.; Maziere, M.

    1991-01-01

    Probing the regional distribution and affinity of receptors in the brain, in vivo, in human and non human primates has become possible with the use of selective ligands labelled with positron emitting radionuclides and positron emission tomography (PET). After describing the techniques used in positron emission tomography to characterize a ligand receptor binding and discussing the choice of the label and the limitations and complexities of the in vivo approach, the results obtained in the PET studies of various neurotransmission systems: dopaminergic, opiate, benzodiazepine, serotonin and cholinergic systems are reviewed

  3. Positron imaging system for plant study

    International Nuclear Information System (INIS)

    Uchida, Hiroshi; Omura, Tomohide; Yamashita, Takaji

    2000-01-01

    The positron imaging system, which we have developed, is composed of two planar detectors which detect gamma-rays. These are placed on either side of a plant onto which tracers labeled with positron emitting nuclides have been fed. A pair of gamma rays produced by the annihilation of the positrons and electrons is measured simultaneously from both directions, to identify the tracer position. This measurement method enables dynamic movements of substances within the plant to be obtained as a two-dimensional image, without contact. (author)

  4. Multimode vibrational couplings in resonant positron annihilation.

    Science.gov (United States)

    d'A Sanchez, Sergio; Lima, Marco A P; Varella, Márcio T do N

    2011-09-02

    The mechanisms for multimode vibrational couplings in resonant positron annihilation are not well understood. We show that these resonances can arise from positron-induced distortions of the potential energy surface (target response to the positron field). Though these distortions can transfer energy into single- and multiquantum vibrations, they have so far been disregarded as a pathway to resonant annihilation. We also compare the existing annihilation theories and show that the currently accepted model can be cast as a special case of the Feshbach annihilation theory.

  5. Porous silicon investigated by positron annihilation

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1989-01-01

    The effect of the anodic conversion in silicon single crystals is investigated by positron lifetime measurements. Anodization at constant current induces changes in the positron lifetime spectrum of monocrystalline silicon samples. It is found that theses changes are primarily dependent on the silicon resistivity. The annihilation parameter behaviour of anodized samples, treated at high temperature under reducing conditions, is also investigated. The results reveal that positron annihilation can be a useful technique to characterize porous silicon formed by anodizing as well as to investigate its thermal behaviour. (author)

  6. Positron Emission Tomography - Computed Tomography (PET/CT)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Positron Emission Tomography - Computed Tomography (PET/CT) Positron emission tomography (PET) ... Emission Tomography – Computed Tomography (PET/CT)? What is Positron Emission Tomography – Computed Tomography (PET/CT) Scanning? Positron emission tomography, ...

  7. Radiation doses at an electron and positron Linac and storage ring

    International Nuclear Information System (INIS)

    Esposito, A.; Pelliccioni, M.; Rindi, A.

    1978-01-01

    The INFN National Laboratory of Frascati (Italy) makes use of a higher energy Linac for different physics experiments and for freeding an electron-positron storage ring (ADONE). For radiation protection purposes a series of gamma dose measurements has been performed during the running of the accelerators along the Linac beam lines and the concrete tunnel that covers the Linac as well as along the storage ring. (author)

  8. Vacuum R and D for CESR (Cornell Electron-positron Storage Ring) upgrade

    International Nuclear Information System (INIS)

    Rao, V.P.

    1995-01-01

    The Cornell Electron-positron Storage Ring has been operating successfully for a number of years now. It has been quite productive for both high energy physics research and the use of the synchrotron radiation (CHESS-Cornell High Energy Synchrotron Source) for studies of biological and physical materials/devices. Vacuum to a great extent restricts the beam current and various steps have been undertaken to improve every aspect of it. 5 refs., 12 figs., 2 tabs., 1 ill

  9. Positron annihilation in gaseous nitrided cold-rolled FeNiTi films

    NARCIS (Netherlands)

    Chechenin, NG; van Veen, A; Galindo, RE; Schut, H; Chezan, A; Boerma, DO; Triftshauser, W; Kogel, G; Sperr, P

    2001-01-01

    Positron beam analysis (PBA) was performed on cold-rolled Fe0.94Ni0.04Ti0.02 foils, which were subjected to different thermal treatments in an atmosphere of a gas mixture of NH3+H-2 (nitriding). The nitriding of the samples in the alpha -region (alphaN) of Lehrer diagram for the Fe-N system produced

  10. Observation of Electron Cloud Instabilities and Emittance Dilution at the Cornell Electron-Positron Storage Ring Test Accelerator

    International Nuclear Information System (INIS)

    Holtzapple, R.L.; Campbell, R.C.; McArdle, K.E.; Miller, M.I.; Totten, M.M.; Tucker, S.L.; Billing, M.G.; Dugan, G.F.; Ramirez, G.A.; Sonnad, K.G.; Williams, H.A.; Flanagan, J.; Palmer, M.A.

    2016-01-01

    Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnotics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains; 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this paper we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions

  11. Observation of Electron Cloud Instabilities and Emittance Dilution at the Cornell Electron-Positron Storage Ring Test Accelerator

    Science.gov (United States)

    Holtzapple, R. L.; Billing, M. G.; Campbell, R. C.; Dugan, G. F.; Flanagan, J.; McArdle, K. E.; Miller, M. I.; Palmer, M. A.; Ramirez, G. A.; Sonnad, K. G.; Totten, M. M.; Tucker, S. L.; Williams, H. A.

    2016-04-01

    Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnotics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains; 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this paper we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions.

  12. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  13. Radiopharmaceutical chemistry for positron emission tomography

    NARCIS (Netherlands)

    Elsinga, PH

    Radiopharmaceutical chemistry includes the selection, preparation, and preclinical evaluation of radiolabeled compounds. This paper describes selection criteria for candidates for positron emission tomography (PET) investigations. Practical aspects of nucleophilic and electrophilic

  14. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  15. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Derenzo, Stephen

    2003-01-01

    The goal of this project is to construct a functioning compact positron tomography, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  16. New Possibilities of Positron-Emission Tomography

    Science.gov (United States)

    Volobuev, A. N.

    2018-01-01

    The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

  17. Ionization and positron emission in giant quasiatoms

    International Nuclear Information System (INIS)

    Soff, G.; Reinhardt, J.; Reus, T. de; Wietschorke, K.H.; Schaefer, A.; Mueller, B.; Greiner, W.; Mueller, U.; Schlueter, P.

    1985-07-01

    Electron excitation processes in superheavy quasiatoms are treated within a relativistic framework. Theoretical results on K-hole production rates as well as delta-electron and positron spectra are compared with experimental data. It is demonstrated that the study of heavy ion collisions with nuclear time delay promises a signature for the spontaneous positron formation in overcritical systems. Corresponding experimental results are confronted with our theoretical hypothesis. Recent speculations on the origin of the observed peak structures in positron spectra are critically reviewed. Atomic excitations are also employed to obtain information on the course of a nuclear reaction. Using a semiclassical picture we calculate the emission of delta-electrons and positrons in deep-inelastic nuclear reactions. Furthermore some consequences of conversion processes in giant systems are investigated. (orig.)

  18. Characterization of lacunar defects by positrons annihilation

    CERN Document Server

    Barthe, M F; Blondiaux, G

    2003-01-01

    Among the nondestructive methods for the study of matter, the positrons annihilation method allows to sound the electronic structure of materials by measuring the annihilation characteristics. These characteristics depend on the electronic density as seen by the positon, and on the electron momentums distribution which annihilate with the positon. The positon is sensible to the coulombian potential variations inside a material and sounds preferentially the regions away from nuclei which represent potential wells. The lacunar-type defects (lack of nuclei) represent deep potential wells which can trap the positon up to temperatures close to the melting. This article describes the principles of this method and its application to the characterization of lacunar defects: 1 - positrons: matter probes (annihilation of electron-positon pairs, annihilation characteristics, positrons sources); 2 - positrons interactions in solids (implantation profiles, annihilation states, diffusion and trapping, positon lifetime spec...

  19. Elastic scattering of slow positrons by helium

    International Nuclear Information System (INIS)

    Amusia, M.Ya.; Cherepkov, N.A.; Chernysheva, L.V.; Shapiro, S.G.

    1976-01-01

    The s-, p-, d- and f-wave phaseshifts for elastic scattering of slow positrons by He are calculated using a simplified version of the random phase approximation with exchange, with virtual positronium formation effect taken into account. (author)

  20. Positron lifetime experiments in indium selenide

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1988-01-01

    Positron lifetime experiments have been performed on as-grown samples which had been isochronally annealed up to 820 K and plastically deformed and these experiments yield a constant lifetime of 282 ± 2 ps which is attributed to bulk positron states in InSe. Electron-irradiated samples exhibit a two-component spectrum, revealing the presence of positron traps which anneal out at about 330 K. The nature of the native shallow donors in InSe is discussed in the light of the results, which support the idea that native donor centres are probably interstitial In atoms rather than Se vacancies. Positron trapping observed in the electron-irradiated samples is attributed to defects related to In vacancies. (author)

  1. Review of linear collider beam-beam interaction

    Energy Technology Data Exchange (ETDEWEB)

    Chen, P.

    1989-01-01

    Three major effects from the interaction of e/sup +/e/sup /minus// beams---disruption, beamstrahlung, and electron-positron pair creation---are reviewed. For the disruption effects we discuss the luminosity enhancement factor, the maximum and rms disruption angles, and the ''kink instability''. All the results are obtained from computer simulations. Scaling laws for the numerical results and theoretical explanations of the computer acquired phenomena are offered wherever possible. For the beamstrahlung effects we concentrate only on the final electron energy spectrum resulting from multiple photon radiation process, and the deflection angle associated with low energy particles. For the effects from electron-positron pair creation, both coherent and incoherent processes of beamstrahlung pair creation are discussed. In addition to the estimation on total number of such pairs, we also look into the energy spectrum and the deflection angle. 17 refs., 23 figs., 1 tab.

  2. Clinical utility of positron emission mammography

    OpenAIRE

    Glass, Shannon B.; Shah, Zeeshan A.

    2013-01-01

    Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomography–computed tomography and can be performed on patients to stage a newly diagnosed malignancy. Revie...

  3. Positron annihilation at grain boundaries in metals

    Czech Academy of Sciences Publication Activity Database

    Kuriplach, J.; Melikhova, O.; Hou, M.; Van Petegem, S.; Zhurkin, E.; Šob, Mojmír

    2007-01-01

    Roč. 4, č. 10 (2007), s. 3461-3464 ISSN 1862-6351. [International Conference on Positron Annihilation /14./. Hamilton, Ontario, 23.07.2006-28.07.2006] R&D Projects: GA AV ČR IAA1041302; GA MŠk OC 147 Institutional research plan: CEZ:AV0Z20410507 Keywords : positron annihilation * grain boundaries * electronic structure Subject RIV: BM - Solid Matter Physics ; Magnetism

  4. Positron astronomy with SPI/INTEGRAL

    International Nuclear Information System (INIS)

    Weidenspointner, G.; Diehl, R.; Strong, A.; Weidenspointner, G.; Skinner, G.K.; Skinner, G.K.; Jean, P.; Knoedlseder, J.; Von Ballmoos, P.; Cordier, B.; Schanne, S.; Winkler, C.

    2008-01-01

    We provide an overview of positron astronomy results that have been obtained using the INTEGRAL spectrometer SPI, and discuss their implications for the still mysterious origin of positrons in our Galaxy. It has long been known that the 511 keV positron annihilation emission is strongest from the central region of our Galaxy. Recently, it has been discovered with the SPI spectrometer that the weaker 511 keV line emission from the inner Galactic disk appears to be asymmetric, with the emission to the west of the Galactic center being about twice as strong than that to the east. This distribution of positron annihilation resembles that of low mass X-ray binaries as observed with the INTEGRAL imager IBIS at hard X-ray energies, suggesting that these systems could provide a significant portion of the positrons in our Galaxy. In addition, the spectrometer SPI has permitted unprecedented spectroscopy of annihilation radiation from the bulge and disk regions of the Galaxy, which commences to yield important insights into the conditions of the medium in which the positrons annihilate. (authors)

  5. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Lecomte, R.; Bentourkia, M.; Benard, F.

    2002-01-01

    Positron Emission Tomography is a sophisticated molecular imaging technique, using a special scanner, that displays the functional status of tissues in the body at the cellular level (their metabolism). It is a diagnostic scan that provides the physician with information not available with traditional anatomic studies such as CT or MRI. PET can detect changes in cell function (disease) long before they are evident as physical (anatomic) changes seen on CT or MRI. In this way PET can add important information about many diseases allowing the physician to make a diagnosis often much earlier than with anatomic imaging techniques such as CT or MRI alone. In addition, in cases where an abnormality is noted on CT or MRI, PET can help differentiate benign changes from changes due to disease. PET scanning also typically images the entire body, unlike CT/MRI which is usually broken up into specific limited body section scans. All cells use glucose as an energy source but cancer cells use much more since they are growing much faster and out of control. This is the basis of imaging with F-18 FDG glucose, the radiotracer agent use in a PET oncology study. The abnormal, accelerated glucose used by cancer cells is detected by the PET scanner that processes the emissions from the F-18 FDG glucose by abnormally high levels of metabolism (tumor)

  6. Positron in nuclear medicine imaging

    International Nuclear Information System (INIS)

    Basu, S.

    2012-01-01

    The last two decades have witnessed a rapid expansion of clinical indications of positron emission tomography (PET) based imaging in assessing a wide range of disorders influencing their clinical management. This is primarily based upon a large dataset of evidence that has been generated over the years. The impact has been most remarkable in the field of cancer, where it takes a pivotal role in the decision making (at initial diagnosis, early response assessment and following completion of therapeutic intervention) of a number of important malignancies. The concept of PET based personalized cancer medicine is an evolving and attractive proposition that has gained significant momentum in recent years. The non-oncological applications of PET and PET/CT are in (A) Cardiovascular Diseases (e.g. Myocardial Viability, Flow reserve with PET Perfusion Imaging and atherosclerosis imaging); (B) Neuropsychiatric disorders (e.g. Dementia, Epileptic Focus detection, Parkinson's Disease, Hyperkinetic Movement Disorders and Psychiatric diseases); (C) Infection and Inflammatory Disorders (e.g. Pyrexia of Unknown origin, complicated Diabetic Foot, Periprosthetic Infection, Tuberculosis, Sarcoidosis, Vasculitic disorders etc). Apart from these, there are certain novel clinical applications where it is undergoing critical evaluation in various large and small scale studies across several centres across the world. The modality represents a classical example of a successful translational research of recent times with a revolutionary and far-reaching impact in the field of medicine. (author)

  7. High energy resolution and first time-dependent positron annihilation induced Auger electron spectroscopty

    International Nuclear Information System (INIS)

    Mayer, Jakob

    2010-01-01

    It was the aim of this thesis to improve the existing positron annihilation induced Auger spectrometer at the highly intense positron source NEPOMUC (NEutron induced POsitron source MUniCh) in several ways: Firstly, the measurement time for a single spectrum should be reduced from typically 12 h to roughly 1 h or even less. Secondly, the energy resolution, which amounted to ΔE/E∼10%, should be increased by at least one order of magnitude in order to make high resolution positron annihilation induced Auger spectroscopy (PAES)-measurements of Auger transitions possible and thus deliver more information about the nature of the Auger process. In order to achieve these objectives, the PAES spectrometer was equipped with a new electron energy analyzer. For its ideal operation all other components of the Auger analysis chamber had to be adapted. Particularly the sample manipulation and the positron beam guidance had to be renewed. Simulations with SIMION registered ensured the optimal positron lens parameters. After the adjustment of the new analyzer and its components, first measurements illustrated the improved performance of the PAES setup: Firstly, the measurement time for short overview measurements was reduced from 3 h to 420 s. The measurement time for more detailed Auger spectra was shortened from 12 h to 80 min. Secondly, even with the reduced measurement time, the signal to noise ratio was also enhanced by one order of magnitude. Finally, the energy resolution was improved to ΔE/E 2,3 VV-transition with PAES. Thus, within this thesis two objectives were achieved: Firstly, the PAES spectrometer was renewed and improved by at least one order of magnitude with respect to the signal to noise ratio, the measurement time and the energy resolution. Secondly, several measurements have been carried out, demonstrating the high performance of the spectrometer. Amongst them are first dynamic PAES measurements and a high resolution measurement of the CuM 2,3 VV

  8. Quantum primary rainbows in transmission of positrons through very short carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Ćosić, M., E-mail: mcosic@vinca.rs; Petrović, S.; Nešković, N.

    2016-04-15

    This paper is devoted to a quantum mechanical consideration of the transmission of positrons of a kinetic energy of 1 MeV through very short (11, 9) single-wall chiral carbon nanotubes. The nanotube lengths are between 50 and 320 nm. The transmission process is determined by the rainbow effects. The interaction potential of a positron and the nanotube is deduced from the Molire’s interaction potential of the positron and a nanotube atom using the continuum approximation. We solve numerically the time-dependent Schrödinger equation, and calculate the spatial and angular distributions of transmitted positrons. The initial positron beam is assumed to be an ensemble of non-interacting Gaussian wave packets. We generate the spatial and angular distributions using the computer simulation method. The examination is focused on the spatial and angular primary rainbows. It begins with an analysis of the corresponding classical rainbows, and continues with a detailed investigation of the amplitudes and phases of the wave functions of transmitted positrons. These analyses enable one to identify the principal and supernumerary primary rainbows appearing in the spatial and angular distributions. They also result in a detailed explanation of the way of their generation, which includes the effects of wrinkling of each wave packet during its deflection from the nanotube wall, and of its concentration just before a virtual barrier lying close to the corresponding classical rainbow. The wrinkling of the wave packets occurs due to their internal focusing. In addition, the wave packets wrinkle in a mutually coordinated way. This explanation may induce new theoretical and experimental investigations of quantum rainbows occurring in various atomic collision processes.

  9. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  10. The energy stabilization for the SLC scavenger beam

    International Nuclear Information System (INIS)

    Hsu, Ian; Browne, M.; Himel, T.; Humphrey, R.; Jobe, K.; Ross, M.; Pellegrin, J.L.; Seeman, J.

    1990-08-01

    The energy of the SLC scavenger beam which is used to produce positrons must be carefully maintained so that the beam can be transported through the collimators in the dispersive region of the extraction line which leads from the Linac to the positron target. A feedforward control loop has been developed to compensate the energy fluctuations due to the beam intensity fluctuations. The loop detects the beam intensities in the damping rings and then calculates how much energy needs to be compensated due to beam loading effects. The energy is corrected by adjusting the acceleration phases of two sets of klystrons right before the extraction. Because there is feedback loop using the same controls, their interaction needs to be carefully treated. This paper presents an overview of the feedforward algorithms. 3 figs

  11. Head-tail instability caused by electron cloud in positron storage rings

    CERN Document Server

    Ohmi, K

    2000-01-01

    In positron or proton storage rings with many closely spaced bunches, a large number of electrons can be generated in the vacuum chamber due to photoemission or secondary emission. The density of this `electron cloud' increases along a bunch train, until the growth saturates under the influence of its own space charge field. In this report, we discuss the possibility of a single-bunch two-stream instability driven by the electron cloud, where any initial head-tail perturbation of the bunch is amplified by the coherent motion of cloud electrons near the beam. Depending on the strength of the beam-electron interaction, the chromaticity and the synchrotron oscillation frequency, this instability either resembles a linac beam break up, or a head-tail instability. We present computer simulations of beam break up and head-tail instabilities for the Low Energy Ring of the KEK B factory, and compare the simulation results with analytical estimates.

  12. Total yield and spectra of positrons produced by channeling radiation from 0.1 ÷ 1.6 GeV electrons

    Science.gov (United States)

    Abdrashitov, S. V.; Bogdanov, O. V.; Dabagov, S. B.; Pivovarov, Yu. L.; Tukhfatullin, T. A.

    2017-07-01

    The hybrid scheme of positron source involving channeling radiation from 0.1 ÷ 1.6 GeV 〈1 0 0〉 channeled electrons in a crystalline W target (radiator) and subsequent electron-positron pair production in a downstream thick amorphous W target (converter) is investigated by means of computer simulation using the BCM-1 code. Computer simulation is carried out taking into account positron energy loss in a thick converter. Total yield of positrons as a function of the thickness of the converter as well as the energy spectrum of positrons for the chosen converter thickness are obtained. According to the calculations, the total yield of positrons produced by channeling radiation from 0.1 ÷ 1.6 GeV electrons in a 10 μm W crystal equals 0.5 ÷ 160 positrons per 103 incident electrons, respectively, with the maximum of positron energy spectrum in the energy range 1 ÷ 3 MeV. Calculations are performed within the framework of the planned experimental program at SPARC_LAB LNF.

  13. Transverse beam shape measurements of intense proton beams using optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Scarpine, Victor E.; /Fermilab

    2012-03-01

    A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.

  14. Solvated Positron Chemistry. Competitive Positron Reactions with Halide Ions in Water

    DEFF Research Database (Denmark)

    Christensen, Palle; Pedersen, Niels Jørgen; Andersen, J. R.

    1979-01-01

    It is shown by means of the angular correlation technique that the binding of positrons to halides is strongly influenced by solvation effects. For aqueous solutions we find increasing values for the binding energies between the halide and the positron with increasing mass of the halide...

  15. Application of a generalisation of the Kohn variational method to the calculation of cross sections for low-energy positron-hydrogen-molecule scattering

    International Nuclear Information System (INIS)

    Armour, E.A.G.

    1984-01-01

    The phaseshift corresponding to the lowest partial wave and the associated approximation to the total cross section are calculated for low-energy positron-hydrogen-molecule scattering using a generalisation of the Kohn variational method. The trial wavefunction is expressed in terms of confocal elliptical coordinates. Except at incident positron energies below about 2 eV, reasonable agreement with experiment is obtained below the positronium formation threshold at 8.63 eV. (author)

  16. Coherent beam-beam effects

    International Nuclear Information System (INIS)

    Chao, A.W.

    1992-01-01

    There are two physical pictures that describe the beam-beam interaction in a storage ring collider: The weak-strong and the strong-strong pictures. Both pictures play a role in determining the beam-beam behavior. This review addresses only the strong-strong picture. The corresponding beam dynamical effects are referred to as the coherent beam-beam effects. Some basic knowledge of the weak-strong picture is assumed. To be specific, two beams of opposite charges are considered. (orig.)

  17. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  18. Clinical application of positron CT

    International Nuclear Information System (INIS)

    Takashima, Tsuneo; Yamaura, Akira; Shishido, Fumio; Tateno, Yukio.

    1981-01-01

    A newley designed positron CT has been applied for neurosurgical patients. The radiopharmaceuticals administered are 13 N-ammonia, 11 C-CO, and 18 F-fluorodeoxyglucose, which are produced and synthesized in the institute using the cyclotron. 13 N-ammonia and 18 F-fluorodeoxyglucose are administered by intravenous injection but 11 C-CO is administered by inhaling. 13 N-ammonia acts as a diffusible tracer and is readily metabolized to glutamine in the brain tissue, but the extraction fraction of the glutamine is so slow that the 13 N-ammonia imaging reflects the distribution of the crebral perfusion. 11 C-CO is combined with the hemoglobin and undiffusible in behavior. This makes the 11 C-CO images conduct the cerebral blood pooling distribution. 18 F-fluorodeoxyglucose is an analogous substance of glucose and is transported within the brain tissue competitively. Then, fluorodeoxyglucose is metabolized to fluorodeoxyglucose-6-phosphate but no further. This characteristic property of fluorodeoxyglucose let 18 F-fluorodeoxyglucose images convey the local cerebral metabolic rate of glucose. In normal volunteer subjects, the distribution of 13 N-ammonia and 18 F-fluorodeoxyglucose appeared in a similar fashion, and was in accordance with the brain tissue. Both tracers were accumulated in particularly high concentrations in the gray matter and the basal ganglia. 11 C-CO activity was prominently accumulated in various dural sinuses and the vascular areas. In stroke patients, old lesions showed a lack of perfusion but fresh lesions showed hyperperfusion surrounded by a decreased perfused area. 18 F-fluorodeoxyglucose activity was decreased in the lesion in spite of the hyperperfusion. (J.P.N.)

  19. Positron research in neuropsychiatric disorders

    International Nuclear Information System (INIS)

    Namura, Ikuro; Inoue, Osamu; Yamasaki, Toshiro.

    1984-01-01

    The principal findings revealed by our 18 F-fluoro-2-deoxyglucose ( 18 FDG) and 15 O-oxygen study were reviewed in the former part of this paper. (1) The effect of surgical severing of fiber connections on the terminal gray matter was clearly demonstrated in the following examples. A patient with the injured left optic radiation showed a markedly decreased 18 FDG uptake in the ipsilateral primary visual cortex. The extent of the decrease was larger in the secondary visual cortex (--60%). The patient with bilateral frontal leukotomy (lobotomy) showed about 30% decrease of oxygen accumulation not only in the frontal cortex but in the anterior half of the temporal cortex. (2) The effect of electrical stimulation of the left median nerve can be detected as an increased 18 FDG accumulation in the corresponding sensory and motor areas in the right precentral and postcentral cortices. The slight to moderate increase in the right striatal region was though to be related to the muscle movement caused by the stimulation. (3) The neuro-degenerative disorders such as Huntington's chorea and Parkinsonism could be diagnosed by demonstrating the decrease of 18 FDG in the degenerating focus or the increase in the secondarily affected area. An example was provided by a case of Huntington's chorea patient who showed a markedly decreased 18 FDG uptake in the striatal region in spite that 13 N-ammonia visualized this area. (4) Dementia gives another field where the 18 FDG and 15 O 2 studies are demonstrated to be quite useful. (5) The 18 FDG studies on the intrinsic psychoses are also reviewed. But consistent results seemed to be very difficult in this area by using labeled sugars and oxygens which are nonspecific gray matter imagers. Therefore, new tracers and new techniques in positron emission tomography are briefly described in the latter part of this paper. (author)

  20. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2011-11-01

    Full Text Available zones capable of introducing a phase shift of zero or p on the alternately out of phase rings of the TEMp0 beams into a unified phase and then focusing the rectified beam to generate a high resolution beam which has a Gaussian beam intensity distribution...

  1. Simulating Terrestrial Gamma Ray Flashes due to cosmic ray shower electrons and positrons

    Science.gov (United States)

    Connell, Paul

    2017-04-01

    The University of Valencia has developed a software simulator LEPTRACK to simulate the relativistic runaway electron avalanches, RREA, that are presumed to be the cause of Terrestrial Gamma Ray Flashes and their powerful accompanying Ionization/Excitation Flashes. We show here results of LEPTRACK simulations of RREA by the interaction of MeV energy electrons/positrons and photons in cosmic ray showers traversing plausible electric field geometries expected in storm clouds. The input beams of MeV shower products were created using the CORSIKA software package from the Karlsruhe Institute of Technology. We present images, videos and plots showing the different Ionization, Excitation and gamma-ray photon density fields produced, along with their time and spatial profile evolution, which depend critically on where the line of shower particles intercept the electric field geometry. We also show a new effect of incoming positrons in the shower, which make up a significant fraction of shower products, in particular their apparent "orbiting" within a high altitude negative induced shielding charge layer, which has been conjectured to produce a signature microwave emission, as well as a short range 511 keV annihilation line. The interesting question posed is if this conjectured positron emission can be observed and correlated with TGF orbital observations to show if a TGF originates in the macro E-fields of storm clouds or the micro E-fields of lightning leaders where this positron "orbiting" is not likely to occur.

  2. Energy-resolved positron annihilation for molecules

    International Nuclear Information System (INIS)

    Barnes, L.D.; Gilbert, S.J.; Surko, C.M.

    2003-01-01

    This paper presents an experimental study designed to address the long-standing question regarding the origin of very large positron annihilation rates observed for many molecules. We report a study of the annihilation, resolved as a function of positron energy (ΔE∼25 meV, full width at half maximum) for positron energies from 50 meV to several eV. Annihilation measurements are presented for a range of hydrocarbon molecules, including a detailed study of alkanes, C n H 2n+2 , for n=1-9 and 12. Data for other molecules are also presented: C 2 H 2 , C 2 H 4 ; CD 4 ; isopentane; partially fluorinated and fluorinated methane (CH x F 4-x ); 1-fluorohexane (C 6 H 13 F) and 1-fluorononane (C 9 H 19 F). A key feature of the results is very large enhancements in the annihilation rates at positron energies corresponding to the excitation of molecular vibrations in larger alkane molecules. These enhancements are believed to be responsible for the large annihilation rates observed for Maxwellian distributions of positrons in molecular gases. In alkane molecules larger than ethane (C 2 H 6 ), the position of these peaks is shifted downward by an amount ∼20 meV per carbon. The results presented here are generally consistent with a physical picture recently considered in detail by Gribakin [Phys. Rev. A 61, 022720 (2000)]. In this model, the incoming positron excites a vibrational Feshbach resonance and is temporarily trapped on the molecule, greatly enhancing the probability of annihilation. The applicability of this model and the resulting enhancement in annihilation rate relies on the existence of positron-molecule bound states. In accord with this reasoning, the experimental results presented here provide the most direct evidence to date that positrons bind to neutral molecules. The shift in the position of the resonances is interpreted as a measure of the binding energy of the positron to the molecule. Other features of the results are also discussed, including large

  3. Positron emission tomography evaluation of sedative properties of antihistamines.

    Science.gov (United States)

    Yanai, Kazuhiko; Zhang, Dongying; Tashiro, Manabu; Yoshikawa, Takeo; Naganuma, Fumito; Harada, Ryuichi; Nakamura, Tadaho; Shibuya, Katsuhiko; Okamura, Nobuyuki

    2011-07-01

    H(1) antihistamines are often used in the medication for allergic diseases, coughs and colds, and insomnia, with or without prescription, even though their sedative properties are a potentially dangerous unwanted side effect that is not properly recognized. These sedative properties have been evaluated using the incidence of subjective sleepiness, objective cognitive and psychomotor functions, and positron emission tomography (PET) measurement of H(1) receptor occupancy. This article reviews the current updated literature on the sedative properties of antihistamines examined by PET measurement of H(1) receptor occupancy. The use of PET to examine antihistamine penetration in the human brain in relation to psychometric and other functional measures of CNS effects is a major breakthrough and provides a new standard by which the functional CNS effects of antihistamines can be related directly to H(1) receptor occupancy. Therapy with antihistamines can be better guided by considering histamine H(1) receptor occupancy from the view of their sedative properties.

  4. Observations and open questions in beam-beam interactions

    International Nuclear Information System (INIS)

    Sen, Tanaji

    2010-01-01

    The first of the hadron colliders, ISR, started operation in 1970. In the following years, the hadron colliders to follow were the SPS (started 1980), the Tevatron (started 1987 first as a fixed target machine), RHIC (started 2000) and most recently the LHC, which started in 2008. HERA was a hybrid that collided electrons and protons. All of these accelerators had or have their performance limited by the effects of the beam-beam interactions. That has also been true for the electron-positron colliders such as LEP, CESR, KEKB and PEPII. In this article I will discuss how the beam-beam limitations arose in some of these machines. The discussion will be focused on common themes that span the different colliders. I will mostly discuss the hadron colliders but sometimes discuss the lepton colliders where relevant. Only a handful of common accelerator physics topics are chosen here, the list is not meant to be exhaustive. A comparative review of beam-beam performance in the ISR, SPS and Tevatron (ca 1989) can be found in reference. Table 1 shows the relevant parameters of colliders (excluding the LHC), which have accelerated protons.

  5. On LCAO positron wavefunctions in crystals

    International Nuclear Information System (INIS)

    Obermayr, W; Sznajder, M

    2006-01-01

    In this work we deal with the construction of delocalized positron wavefunctions in crystalline solids within the linear combination of atomic orbitals (LCAO) scheme. The present method leads to an accurate wavefunction of a positron, both in the core and in the interstitial region of a crystal. Furthermore, its representation by a superposition of atomic orbitals is simple enough for the application to calculations of expectation values, like e.g. of accurate electron-positron annihilation rates (high momentum components). The representation of the positron wavefunction can be optimized with respect to the two points of view: firstly, the number of orbitals in the LCAO representation can be minimized (e.g. within the localized spherical orbitals (LSO) method) or, secondly, the orbitals can be chosen to be well-localized around their atoms and vanishing near all others: this leads to the computational advantage, that three- or multicenter integrals arising during numerical calculations can be replaced by oneand two-center integrals which are treated using standard numerical techniques in spherical polar or elliptic coordinates. The transformation from the first into the second representation can be performed via a 'fuzzy' cellular partitioning of the crystal volume via an analytically continuous shape-function. Finally we demonstrate our method in the case of a positron in lithium

  6. Positron Annihilation in the Undergraduate Laboratory

    Science.gov (United States)

    Engbrecht, Jason

    2017-04-01

    While there are a variety of undergraduate laboratory experiments in the literature, they tend to focus on specific positron experiments and use specialized equipment that limit their flexibility. Here we present a positron spectroscopy experimental apparatus designed for the undergraduate lab. Rather than specialized pulse processing the apparatus utilizes a PC oscilloscope as its primary data acquisition utility with pulse processing happening in software instead of hardware. This allows the apparatus to explore a variety of physical phenomena with the positron annihilation including material science, 2 and 3 gamma annihilation properties, polarimetry via Compton scattering, QED tests, and local hidden variable theories. The supporting software is flexible and allows students to pursue these experiments through exploration rather than simply supporting data acquisition. St. Olaf College.

  7. Positron Spectroscopy of Nanodiamonds after Hydrogen Sorption

    Directory of Open Access Journals (Sweden)

    Lyudmila Nikitina

    2018-01-01

    Full Text Available The structure and defects of nanodiamonds influence the hydrogen sorption capacity. Positronium can be used as a sensor for detecting places with the most efficient capture of hydrogen atoms. Hydrogenation of carbon materials was performed from gas atmosphere. The concentration of hydrogen absorbed by the sample depends on the temperature and pressure. The concentration 1.2 wt % is achieved at the temperature of 243 K and the pressure of 0.6 MPa. The hydrogen saturation of nanodiamonds changes the positron lifetime. Increase of sorption cycle numbers effects the positron lifetime, as well as the parameters of the Doppler broadening of annihilation line. The electron-positron annihilation being a sensitive method, it allows detecting the electron density fluctuation of the carbon material after hydrogen saturation.

  8. Cross section measurements for production of positron emitters for PET imaging in carbon therapy

    Science.gov (United States)

    Salvador, S.; Colin, J.; Cussol, D.; Divay, C.; Fontbonne, J.-M.; Labalme, M.

    2017-04-01

    In light ion beam therapy, positron (β+) emitters are produced by the tissue nuclei through nuclear interactions with the beam ions. They can be used for the verification of the delivered dose using positron emission tomography by comparing the spatial distribution of the β+ emitters activity to a computer simulation taking into account the patient morphology and the treatment plan. However, the accuracy of the simulation greatly depends on the method used to generate the nuclear interactions producing these emitters. In the case of Monte Carlo (MC) simulations, the nuclear interaction models still lack the required accuracy due to insufficient experimental cross section data. This is particularly true for carbon therapy where literature data on fragmentation cross sections of a carbon beam with targets of medical interest are very scarce. Therefore, we performed at GANIL in July 2016 measurements on β+ emitter production cross sections with a carbon beam at 25, 50, and 95 MeV/nucleon on thin targets (C, N, O, and PMMA). We extracted the production cross section of C,1110, 13N, and O,1514 that are essential to constrain or develop MC nuclear fragmentation models.

  9. Beam-beam and impedance

    CERN Document Server

    White, S.

    2014-07-17

    As two counter-rotating beams interact they can give rise to coherent dipole modes. Under the influence of impedance these coherent beam-beam modes can couple to higher order head-tail modes and lead to strong instabilities. A fully self-consistent approach including beam-beam and impedance was used to characterize this new coupled mode instability and study possible cures such as a transverse damper and high chromaticity.

  10. Nuclear physics with radioactive beams

    International Nuclear Information System (INIS)

    Bimbot, R.

    1994-01-01

    Radioactive beams can be produced through two different and complementary ways:i. the production at rest of radioactive nuclei, followed by their acceleration using conventional techniques.This method is the best for producing low energy radioactive beams. ii. the fragmentation of high energy heavy ion beams ( over 30 MeV/u), followed by the selection and purification of a given secondary beam using magnetic spectrometers. This technique leads to high energy radioactive beams. Both methods have now been used in several laboratories in the world. Examples of the corresponding experimental equipment will be presented, and especially Lise 3, Sissi, and the spiral project at GANIL. Radioactive beams have used for several purposes in nuclear physics: i. they constitute the fastest technique ever used for transferring exotic nuclei from the production point to a well shielded place where detectors can be operated for studying their properties in good conditions. At the same time, they can be identified using solid state detectors and the time-of-flight/energy-loss technique. Illustrations of the results obtained in this domain (mass and half-life measurements, recent identification of the isotope sup 1 sup 0 sup 0 Sn) is given. ii. they are used to induce nuclear reactions which may bring new information on nuclear structure. For example, the measurement of total reaction cross-sections for many radioactive projectiles revealed the existence of halo nuclei such as sup 1 sup 1 Li and sup 1 sup 1 Be. Beams of these isotopes have been extensively used to precise their structure.iii. in the domain of nuclear astrophysics, radioactive beams are used to measure, through direct or indirect methods, the cross sections for reactions of crucial interest in nucleosynthesis. Finally, radioactive beams of light positron emitters, such as sup 1 sup 9 Ne have considerable interest for medical purposes and especially in the growing field of heavy-ion radiotherapy. 8 figs., 24 refs

  11. Features and applications of positron emission tomography

    International Nuclear Information System (INIS)

    Fan Mingwu

    1997-01-01

    Positron emission tomography, the so-called world's smartest camera, is based on a NaI or BGO detector and imaging of positron-emitting radioisotopes which are introduced as a tracer into the regional tissue or organ of interest. With the aid of a computer visual images of a series of these distributions can be built into a picture of the functional status of the tissue or organ being imaged. This highly accurate imaging technique is already widely used for clinical diagnostics heart disease, brain disorder, tumors and so on

  12. Recent considerations of the GSI positron peaks

    International Nuclear Information System (INIS)

    Soff, G.; Reinhardt, J.; Reus, J. de; Ionescu, D.; Schramm, S.; Mueller, B.; Greiner, W.

    1987-08-01

    In this report we examine various attempts to explain the GSI positron peaks. After the presentation of recent experimental data we briefly sketch theoretical investigations concerning the new particle hypothesis. The failure of standard models employing a linear coupling led to more exotic scenarios for particle production. One exciting recent idea is outlined. After that we treat the possible formation of a resonance in ordinary Bhabha scattering which could represent a time-reversed channel to the observations in heavy-ion collisions. Finally we discuss the poly-positronium model and a purely atomic physics model to interprete the GSI positron events. (orig./HSI)

  13. Heuristic theory of positron-helium scattering.

    Science.gov (United States)

    Drachman, R. J.

    1971-01-01

    An error in a previous modified adiabatic approximation (Drachman, 1966), due to a lack of generality in the form of the short-range correlation part of the wave function for L greater than zero, is corrected heuristically by allowing the monopole suppression parameter to depend on L. An L-dependent local potential is constructed to fit the well-known positron-hydrogen s, p, and d wave phase shifts below the rearrangement threshold. The same form of potential yields a positron-helium cross-section in agreement with a recent experimental measurement near threshold.

  14. Positron emission tomography imaging of gene expression

    International Nuclear Information System (INIS)

    Tang Ganghua

    2001-01-01

    The merging of molecular biology and nuclear medicine is developed into molecular nuclear medicine. Positron emission tomography (PET) of gene expression in molecular nuclear medicine has become an attractive area. Positron emission tomography imaging gene expression includes the antisense PET imaging and the reporter gene PET imaging. It is likely that the antisense PET imaging will lag behind the reporter gene PET imaging because of the numerous issues that have not yet to be resolved with this approach. The reporter gene PET imaging has wide application into animal experimental research and human applications of this approach will likely be reported soon

  15. Positron trapping at dislocations in metals

    International Nuclear Information System (INIS)

    Bergersen, B.; McMullen, T.

    1977-01-01

    The trapping rate of positrons at dislocations in metals, and its temperature dependence, are calculated. Two different trapping processes, with the excess energy absorbed in either electron-hole pair formation or by phonon creation, are considered and the former is found to be the most important. An extension of the theory to include depletion of the positron density around the dislocations in a diffusion approximation is included. The trapping is found to be transition limited if the temperature is low or the trap potential shallow. At room temperature diffusion is important for deep traps. (author)

  16. Clinical utility of positron emission mammography.

    Science.gov (United States)

    Glass, Shannon B; Shah, Zeeshan A

    2013-07-01

    Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomography-computed tomography and can be performed on patients to stage a newly diagnosed malignancy. Review of mammograms together with magnetic resonance or PEM images improves detection of disease.

  17. Apparatus for photon activation positron annihilation analysis

    Science.gov (United States)

    Akers, Douglas W [Idaho Falls, ID

    2007-06-12

    Non-destructive testing apparatus according to one embodiment of the invention comprises a photon source. The photon source produces photons having predetermined energies and directs the photons toward a specimen being tested. The photons from the photon source result in the creation of positrons within the specimen being tested. A detector positioned adjacent the specimen being tested detects gamma rays produced by annihilation of positrons with electrons. A data processing system operatively associated with the detector produces output data indicative of a lattice characteristic of the specimen being tested.

  18. Evaluation of Timepix silicon detector for the detection of 18F positrons

    Science.gov (United States)

    Wang, Q.; Tous, J.; Liu, Z.; Ziegler, S.; Shi, K.

    2014-05-01

    Timepix is an evolving energy and position sensitive pixel detector. It consists of a silicon detector (sensitive layer 300 μm thick) bump-bonded to the Timepix readout chip developed by the Medipix2 collaboration. This study aims to test the feasibility of using the acquired energy and position signals from Timepix for positron imaging. The signals of the commonly used fluorine-18 PET (positron emission tomography) tracer [18F]FDG were measured using Timepix operated both in single particle counting (Medipix) and in time over threshold (TOT) modes. The spatial resolution (SR) was measured using the absorber edge method (AEM) and was calculated from the over-sampled line spread function. The track of a positron in the Timepix detector was characterized as a cluster and the energy weighted centroid of each cluster was considered as readout for the position of the positron incidence. The measurement results were compared with theoretical predictions using Monte-Carlo simulations. In addition, imaging of a tissue slice of a mouse heart was analysed with reference to standard phosphor plate imaging. Our results show that the SR was improved from 177.1±4.1 μm (centroid without energy weighting) to 155.5±3.1 μm μm (centroid with energy weighting). About 12% enhancement of SR was achieved with energy information in TOT mode. The sensitivity of Timepix was 0.35 cps/Bq based on the measurements. The measuring background and the ratio between detected positrons and gamma rays were also evaluated and were found to be consistent with theoretical predictions. A small enhancement of image quality was also achieved by applying energy information to the data of the measured tissue sample. Our results show that the inclusion of energy information could slightly enhance the positron measurement compared to without energy information and the Timepix provides a high SR and sensitivity for positron detection. Thus, Timepix is a potentially effective tool for 2D positron imaging.

  19. Measurement of positron annihilation lifetimes for positron burst by multi-detector array

    Science.gov (United States)

    Wang, B. Y.; Kuang, P.; Liu, F. Y.; Han, Z. J.; Cao, X. Z.; Zhang, P.

    2018-03-01

    It is currently impossible to exploit the timing information in a gamma-ray pulse generated within nanoseconds when a high-intensity positron burst annihilation event occurs in a target using conventional single-detector methods. A state-of-the-art solution to the problem is proposed in this paper. In this approach, a multi-detector array composed of many independent detection cells mounted spherically around the target is designed to detect the time distribution of the annihilated gamma rays generated following, in particular, a positron burst emitting huge amounts of positrons in a short pulse duration, even less than a few nano- or picoseconds.

  20. Solvated Positron Chemistry - Positron Reactions with Pseudo-Halide Ions in Water

    DEFF Research Database (Denmark)

    Mogensen, O. E.; Pedersen, Niels Jørgen; Andersen, Jan Rud

    1982-01-01

    The hydrated positron e+aq reactions with SCN−, OCN−, CN−, S2− were studied by means of the angular correlation technique. The positron forms bound states with SCN−, CN−, and S2− but not with OCN−. Apparently, the e+aq reaction with SH− results in a positron bound state with S2−. It was difficult...... to determine the shapes of the bound-state angular correlation curves. Only in the SCN− case could a very rough estimate of the rate constant be obtained. Estimates of the binding energies relative to those of the corresponding halide ion states could be determined for SCN− and S2−....

  1. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  2. Thermal Shock Structural Analyses of a Positron Target

    International Nuclear Information System (INIS)

    2002-01-01

    In the positron source of the Stanford Linear Collider (SLC), the electron beam collides with a tungsten-rhenium target. As the beam passes into the material, thermal energy is created that heats the material to several hundred degrees centigrade on a time scale of nanoseconds. The heating of the material results in thermal stresses that may be large enough to cause material failure. The analyses calculate the thermal shock pressure and stress pulses as they move throughout the material due to the rapid energy deposition. Failure of the target occurred after three years of operation with an elevated power deposition toward the end of the three years. The calculations were made with the LLNL coupled heat transfer and dynamic solid mechanics analysis codes, TOPAZ3D and DYNA3D, and the thermal energy deposition was calculated with the SLAC Electron Gamma Shower (EGS) code simulating the electron-induced cascade. Material fatigue strength, experimentally measured properties for the non-irradiated and irradiated material, as well as the calculated stress state are evaluated in assessing the cause for the target failure

  3. Electron-positron-photon cascades in the strong laser field

    Science.gov (United States)

    Legkov, Maxim; Fedotov, Alexander

    2012-06-01

    At nearest future several ambitious projects (such as ELI and HiPER) may provide laser filed intensity up to 10^23--10^24 W/cm^2. In such strong fields quantum effects are essential. The most important among them is production of QED cascades. In this paper external field intensity is considered as ultra-relativistic but subcritical. Using a model of two colliding counter-propagating laser beams it was shown that the number of particles during the process is growing exponentially in time. This leads to vast formation of electron-positron-photon plasma. According to numerical simulations, this plasma quickly absorbs an essential part of the energy of the laser field thus leading to its depletion. Numerical simulation has been also performed for a case of high-energetic particle and laser beam collision. Probability rates of direct and recombination processes have been theoretically studied. Under some conditions, recombination may come into play and suppress cascade development. Using approximation of radiation in forward direction, system of kinetic equations, which describes plasma evaluation, was constructed. According to qualitative estimations based on kinetic equations, it was shown that recombination processes can be neglected for optical frequencies range of external field.

  4. Electron-positron pair production by electromagnetic pulses

    International Nuclear Information System (INIS)

    Bulanov, S. S.; Narozhny, N. B.; Mur, V. D.; Popov, V. S.

    2006-01-01

    Electron-positron pair production in vacuum by a single focused laser pulse and by two counter-propagating colliding focused pulses is analyzed. A focused laser pulse is described using a realistic three-dimensional model based on an exact solution of Maxwell's equations. In particular, this model reproduces an important property of focused beams, namely, the existence of two types of waves with a transverse electric or magnetic vector (e-or h-polarized wave, respectively). The dependence of the number of produced pairs on the radiation intensity and focusing parameter is studied. It has been shown that the number of pairs produced in the field of a single e-polarized pulse is many orders of magnitude larger than that for an h-polarized pulse. The pulse-intensity dependence of the number of pairs produced by a single pulse is so sharp that the total energy of pairs produced by the e-polarized pulse with intensity near the intensity I S 4.65 x 10 29 W/cm 2 characteristic of QED is comparable with the energy of the pulse itself. This circumstance imposes a natural physical bound on the maximum attainable intensity of a laser pulse. For the case of two colliding circularly polarized pulses, it is shown that pair production becomes experimentally observable when the intensity of each beam is I ∼ 10 26 W/cm 2 , which is one to two orders of magnitude lower than that for a single pulse

  5. Mechanical design and development of a high power target system for the SLC Positron Source

    International Nuclear Information System (INIS)

    Reuter, E.; Mansour, D.; Porter, T.; Sax, W.; Szumillo, A.

    1991-12-01

    In order to bring the SLC Positron Source luminosity up to design specifications, the previous (stationary) positron target had to be replaced with a version which could reliably dissipate the higher power levels and cyclic pulsed thermal stresses of the high intensity 33GeV electron beam. In addition to this basic requirement, the new target system had to meet SLAC's specifications for Ultra High Vacuum, be remotely controllable, ''radiation hard,'' and designed in such a way that it could be removed and replaced quickly and easily with minimum personnel exposure to radiation. It was also desirable to integrate the target and collection components into a compact, easily manufacturable, and easily maintainable module. This paper briefly summarize the mechanical design and development of the new modular target system, its associated controls and software, alignment, and the quick removal system. Operational experience gained with the new system over the first running cycle is also summarized

  6. Design of a polarimeter for slow e sup + beams

    CERN Document Server

    Kumita, T; Hamatsu, R; Hirose, M; Hirose, T; Irako, M; Kawasaki, N; Yang, J

    2000-01-01

    A polarimeter which utilizes ortho-positronium quenching in a magnetic field is used to measure polarization of slow positron beams. This polarimeter is employed for a polarization measurement at an e sup + beam system where the beam is provided from the beta sup + decay of sup 2 sup 7 Si produced via the sup 2 sup 7 Al(p,n) sup 2 sup 7 Si reaction caused by proton irradiation. The beam polarization is determined to be 38.4+-4.0(statistical)+-8.7(systematic)%.

  7. Positron Transport and Annihilation in the Galactic Bulge

    Directory of Open Access Journals (Sweden)

    Fiona Helen Panther

    2018-03-01

    Full Text Available The annihilation of positrons in the Milky Way Galaxy has been observed for ∼50 years; however, the production sites of these positrons remains hard to identify. The observed morphology of positron annihilation gamma-rays provides information on the annihilation sites of these Galactic positrons. It is understood that the positrons responsible for the annihilation signal originate at MeV energies. The majority of sources of MeV positrons occupy the star-forming thin disk of the Milky Way. If positrons propagate far from their sources, we must develop accurate models of positron propagation through all interstellar medium (ISM phases in order to reveal the currently uncertain origin of these Galactic positrons. On the other hand, if positrons annihilate close to their sources, an alternative source of MeV positrons with a distribution that matches the annihilation morphology must be identified. In this work, I discuss the various models that have been developed to understand the origin of the 511 keV line from the direction of the Galactic bulge, and the propagation of positrons in the ISM.

  8. Direct evidence for positron annihilation from shallow traps

    DEFF Research Database (Denmark)

    Linderoth, Søren; Hidalgo, C.

    1987-01-01

    For deformed Ag the temperature dependence of the positron lifetime parameters is followed between 12 and 300 K. Clear direct evidence for positron trapping and annihilation at shallow traps, with a positron binding energy of 9±2 meV and annihilation characteristics very similar to those...

  9. E-line: A new crystal collimator beam line for source size measurements at CHESS

    International Nuclear Information System (INIS)

    White, Jeffrey A.; Revesz, Peter; Finkelstein, Ken

    2007-01-01

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring

  10. Probing space–time structure of new physics with polarized beams ...

    Indian Academy of Sciences (India)

    Abstract. At the international linear collider large beam polarization of both the elec- tron and positron beams will enhance the signature of physics due to interactions that are beyond the standard model. Here we review our recently obtained results on a general model-independent method of determining for an arbitary ...

  11. Positron Scattering from Molecules: An Experimental Cross Section Compilation for Positron Transport Studies and Benchmarking Theory

    Science.gov (United States)

    Brunger, M. J.; Buckman, S. J.; Ratnavelu, K.

    2017-06-01

    We present a compilation of recommended positron-molecule cross sections for a range of scattering processes including elastic scattering, vibrational excitation, discrete electronic-state excitation, positronium formation, ionization, and also for the grand total cross section. Where possible, in particular for possible application in positron transport simulations for a given molecule, we try and list data for energies in the range 0.1-1000 eV although in practice the actual energy is highly target-molecule and scattering process specific. Aside from being relevant to positron transport studies, through, for example, Monte Carlo simulations, the present compilation should also be germane for benchmarking the validity and accuracy of positron-molecule scattering calculations and, just as importantly, to allow a comparison with corresponding electron scattering results. That latter comparison can shed real light on the projectile-target interactions that underpin the scattering dynamics.

  12. In-beam PET at high-energy photon beams: a feasibility study

    Science.gov (United States)

    Müller, H.; Enghardt, W.

    2006-04-01

    For radiation therapy with carbon ion beams, either for the stable isotope 12C or for the radioactive one 11C, it has been demonstrated that the β+-activity distribution created or deposited, respectively, within the irradiated volume can be visualized by means of positron emission tomography (PET). The PET images provide valuable information for quality assurance and precision improvement of ion therapy. Dedicated PET scanners have been integrated into treatment sites at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany, to make PET imaging feasible during therapeutic irradiation (in-beam PET). A similar technique may be worthwhile for radiotherapy with high-energy bremsstrahlung. In addition to monitoring the dose delivery process which in-beam PET has been primarily developed for, it may be expected that radiation response of tissue can be detected by means of in-beam PET. We investigate the applicability of PET for treatment control in the case of using bremsstrahlung spectra produced by 15-50 MeV electrons. Target volume activation due to (γ, n) reactions at energies above 20 MeV yields moderate β+-activity levels, which can be employed for imaging. The radiation from positrons produced by pair production is not presently usable because the detectors are overloaded due to the low duty factor of medical electron linear accelerators. However, the degradation of images caused by positron motion between creation and annihilation seems to be tolerable.

  13. Beam cooling

    OpenAIRE

    Danared, H

    2006-01-01

    Beam cooling is the technique of reducing the momentum spread and increasing the phase-space density of stored particle beams. This paper gives an introduction to beam cooling and Liouville’s theorem, and then it describes the three methods of active beam cooling that have been proven to work so far, namely electron cooling, stochastic cooling, and laser cooling. Ionization cooling is also mentioned briefly.

  14. Molecular beams

    International Nuclear Information System (INIS)

    Pendelbury, J.M.; Smith, K.F.

    1987-01-01

    Studies with directed collision-free beams of particles continue to play an important role in the development of modern physics and chemistry. The deflections suffered by such beams as they pass through electric and magnetic fields or laser radiation provide some of the most direct information about the individual constituents of the beam; the scattering observed when two beams intersect yields important data about the intermolecular forces responsible for the scattering. (author)

  15. Stability of a positron lifetime measurement system, and investigation the types and concentrations of defects induced by10 MeV electron irradiation on n- and p-types Si

    Directory of Open Access Journals (Sweden)

    E Tayebfard

    2015-07-01

    Full Text Available Positron annihilation lifetime spectroscopy method with valuation of non-destructive investigation of material, provides information about electron density, defect concentration, type of defects and atoms around the defects. The stability of the system was tested with a source. The time resolution of the whole system has been derived about 365 ps at FWHM. Then n- and p-type silicon samples were irradiated with a 10 MeV electron beam with dosage of 3, 12, and 30 kGy. Three components were fitted to the lifetime spectra using the PAScual program. The first component is related to the positron annihilation in the positron source which was obtained 186 ps. The second component is related to the positron annihilation lifetime in the sample bulk which was obtained 218 ps. The last lifetime component which is related to the positron annihilation in defect was small and sample dependent

  16. A positron annihilation study of hydrated DNA

    DEFF Research Database (Denmark)

    Warman, J. M.; Eldrup, Morten Mostgaard

    1986-01-01

    Positron annihilation measurements are reported for hydrated DNA as a function of water content and as a function of temperature (20 to -180.degree. C) for samples containing 10 and 50% wt of water. The ortho-positronium mean lifetime and its intensity show distinct variations with the degree of ...

  17. Tomography of positrons with SPECT systems

    International Nuclear Information System (INIS)

    Isoardi, Roberto A.

    1999-01-01

    The tomography for emissions of positrons (PET) demonstrate the clinical uses to provide information in the area of neurology, cardiology and principally, in oncology. This chapter describes the principles of the functioning and instrumentation, clinical applications and the state of the art

  18. Is positron emission tomography useful in stroke?

    NARCIS (Netherlands)

    DeReuck, J; Leys, D; DeKeyser, J

    Positron emission tomography (PET) has been widely used in the study of stroke and related cerebrovascular diseases. It has shown the various stages leading to cerebral infarction and defined the significance of the ischaemic penumbra. PET scan can predict the clinical outcome of patients with acute

  19. Positron emission tomography in malignant haematological disease

    NARCIS (Netherlands)

    Schot, Bartholomeus Wilhelmus

    2007-01-01

    Positron emission tomography (PET) is a diagnostic technique with a promising role especially in the haemato-oncology. Although its use in the management ; of malignant lymphoma seems to be established already, much about the true potential and drawbacks of FDG-PET in this disease are still unknown.

  20. The Story of Large Electron Positron Collider

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 7; Issue 11. The Story of Large Electron Positron Collider - Experiments done at LEP. S N Ganguli. General Article Volume 7 Issue 11 November 2002 pp 18-34. Fulltext. Click here to view fulltext PDF. Permanent link:

  1. The Story of Large Electron Positron Collider

    Indian Academy of Sciences (India)

    The Story of Large Electron Positron Collider. 2. Experiments done at LEP. S N Ganguli is at the Tata. Institute of Fundamental. Research, Mumbai. He is ...... team of engineers and technicians of CERN. The preci- sion measurements at LEP left no one in doubt that the understanding of physics through the standard model is.

  2. The Story of Large Electron Positron Collider

    Indian Academy of Sciences (India)

    vertex. This is followed by a general tracking detec- tor to measure momentum of charged particles from the curvature of the tracks in a magnetic field. Electrons, positrons and photons are then detected via their en- ergy deposits iIi electromagnetic calorimeter (like crys- tals, lead-glass, lead-scintillators, etc.); these detectors.

  3. Progress Towards a Practical Multicell Positron Trap

    Science.gov (United States)

    Danielson, J. R.

    2013-10-01

    The physics and technology of positron confinement is central to a range of applications at the forefront of antimatter science. Progress in this area has been driven by the development of a suite of novel non-neutral plasma techniques whereby up to 4 ×109 positrons have now been trapped and stored. However the next generation of experiments will require orders of magnitude more positrons. This talk describes techniques to increase storage capacity to >=1012 using a novel multi-cell trap architecture. Plasmas will be stored in separate Penning-Malmberg traps (``cells'') arranged in parallel off the magnetic axis to maximize use of the magnetic field volume while minimizing the required confinement voltages. Experiments with electrons in a test structure will be described to explore the basic physics and technology of the multicell concept and to set the design of a 21-cell trap for 1012 positrons. Over 50% of a trapped plasma has been injected into an off-axis cell, and hour-long confinement of 2 ×108 particles has been achieved using rotating electric fields. Experiments are under way to identify the limits of the injection process and demonstrate confinement >1010 particles in a single off-axis cell using kilovolt confinement potentials. In collaboration with N. C. Hurst, C. J. Baker, and C. M. Surko. This work is supported by U.S. DTRA and the U.S. DOE/NSF plasma partnership.

  4. Principles and applications of positron & positronium chemistry

    National Research Council Canada - National Science Library

    Jean, Y. C; Mallon, P. E; Schrader, D. M

    2003-01-01

    ... Chemistry," offered at the University of Missouri-Kansas City (UMKC). Instructors were those scientists most active in positronium chemistry, P. Coleman, J. Duplatre, H. Stoll, D.M. Schrader, R.M. Nieminen, and Y.C. Jean who served as the official instructor at UMKC. During the positron summer school, the idea of publishing a graduate-level te...

  5. Positron emission tomography of the lung

    International Nuclear Information System (INIS)

    Wollmer, P.

    1984-01-01

    Positron emission tomography enables the distribution of positron emitting isotopes to be imaged in a transverse plane through the body and the regional concentration of the isotope to be measured quantitatively. This thesis reports some applications of positron emission tomography to studies of pulmonary pathophysiology. Measurements in lung phantoms showed that regional lung density could be measured from a transmission tomogram obtained with an external source of positron emitting isotope. The regional, fractional blood volume was measured after labelling the blood with carbon-11-monoxide. Regional extravascular lung density (lung tissue and interstitial water per unit thoracic volume) was obtained by subtracting fractional blood volume from lung density. Measurements in normal subjects revealed large regional variations in lung density and fractional blood volume in the supine posture. Extravascular lung density showed a more uniform distribution. The technique has been used to study patients with chronic interstitial pulmonary oedema, pulmonary sarcoidosis and fibrosis, pulmonary arterial hypertension and patients with intracardiac, left-to-right shunt. Tomographic measurements of pulmonary tissue concentration of radionuclides are difficult, since corrections for the blood content and the inflation of the lung must be applied. A simultaneous measurement of lung density and fractional blood volume allows such corrections to be made and the extravascular tracer concentration to be calculated. This has been applied to measurements of the tissue penetration of carbon-11-labelled erythromycin in patients with lobar pneumonia. (author)

  6. Study on low-energy positron polarimetry

    Indian Academy of Sciences (India)

    2Physics Department, Tel Aviv University, Tel Aviv 69978, Israel. 3Physics Department ... pends on the orientation of the electron/positron spin in a magnetic field have been successfully demonstrated at the ... The cross-section for Bhabha scattering may be written in the center-of-mass system as dσ. dΩ. ∼. (1 + cos θ)2.

  7. Positron emission tomography : measurement of transgene expression

    NARCIS (Netherlands)

    de Vries, EFJ; Vaalburg, W

    Noninvasive and repetitive imaging of transgene expression can play a pivotal role in the development of gene therapy strategies, as it offers investigators a means to determine the effectiveness of their gene transfection protocols. In the last decade, imaging of transgene expression using positron

  8. Positron Interactions with Atoms and Ions

    Science.gov (United States)

    Bhatia, Anand K.

    2012-01-01

    Dirac, in 1928, combining the ideas of quantum mechanics and the ideas of relativity invented the well-known relativistic wave equation. In his formulation, he predicted an antiparticle of the electron of spin n-bar/2. He thought that this particle must be a proton. Dirac published his interpretation in a paper 'A theory of electrons and protons.' It was shown later by the mathematician Hermann Weyl that the Dirac theory was completely symmetric between negative and positive particles and the positive particle must have the same mass as that of the electron. In his J. Robert Oppenheimer Memorial Prize Acceptance Speech, Dirac notes that 'Blackett was really the first person to obtain hard evidence for the existence of a positron but he was afraid to publish it. He wanted confirmation, he was really over cautious.' Positron, produced by the collision of cosmic rays in a cloud chamber, was detected experimentally by Anderson in 1932. His paper was published in Physical Review in 1933. The concept of the positron and its detection were the important discoveries of the 20th century. I have tried to discuss various processes involving interactions of positrons with atoms and ions. This includes scattering, bound states and resonances. It has not been possible to include the enormous work which has been carried out during the last 40 or 50 years in theory and measurements.

  9. Positron annihilation spectroscopy in condensed matter

    International Nuclear Information System (INIS)

    Brauer, G.

    1982-09-01

    The topic of positron annihilation spectroscopy (PAS) is the investigation of all aspects connected with the annihilation of slow positrons. This work deals with the application of PAS to different problems of materials science. The first chapter is an introduction to fundamental aspects of positron annihilation, as far as they are important to the different experimental techniques of PAS. Chapter 2 is concerned with the information obtainable by PAS. The three main experimental techniques of PAS (2γ-angular correlation, positron lifetime and Doppler broadening) are explained and problems in the application of these methods are discussed. Chapter 3 contains experimental results. According to the different fields of application it was subgrouped into: 1. Investigations of crystalline solids. Detection of structural defects in Cu, estimation of defect concentrations, study of the sintering of Cu powders as well as lattice defects in V 3 Si. 2. Chemical investigations. Structure of mixed solvents, selective solvation of mixed solvents by electrolytes as well as the micellization of sodium dodecylsulphate in aqueous solutions. 3. Investigations of glasses. Influence of heat treatment and production technology on the preorder of X-amorphous silica glass as well as preliminary measurements of pyrocerams. 4. Investigations of metallic glasses. Demonstration of the influence of production technology on parameters measurable by PAS. Chapter 4 contains a summary as well as an outlook of further applications of PAS to surface physics, medicine, biology and astrophysics. (author)

  10. Positron Annihilation Study of Defects in Succinonitrile

    DEFF Research Database (Denmark)

    Eldrup, Morten Mostgaard; Pedersen, Niels Jørgen; Sherwood, J. N.

    1979-01-01

    Positron lifetime and angular correlation measurements have been made on the plastic crystal succinonitrile. They confirm the phase transition at 234 ± 1 K. In the plastic phase the average orthopositronium lifetime increases with temperature and saturates at the highest temperatures. This is int...

  11. PAES: Positron annihilation induced Auger electron spectrometer

    Directory of Open Access Journals (Sweden)

    Christoph Hugenschmidt

    2015-08-01

    Full Text Available Positron annihilation induced Auger electron spectroscopy (PAES is a newly developed application for surface studies with high elemental selectivity and exceptional surface sensitivity. The instrument is operated by the Technische Universität München and is located at NEPOMUC.

  12. A positron annihilation study of hydrated DNA

    DEFF Research Database (Denmark)

    Warman, J. M.; Eldrup, Morten Mostgaard

    1986-01-01

    Positron annihilation measurements are reported for hydrated DNA as a function of water content and as a function of temperature (20 to -180.degree. C) for samples containing 10 and 50% wt of water. The ortho-positronium mean lifetime and its intensity show distinct variations with the degree...

  13. Nonlinear interaction of colliding beams in particle storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, J C; Month, M

    1979-01-01

    When two beams of high energy particles moving in opposite directions are brought into collision, a large amount of energy is available for the production of new particles. However to obtain a sufficiently high event rate for rare processes, such as the production of the intermediate vector boson (Z/sub 0/ and W/sup + -/), large beam currents are also required. Under this circumstance, the high charge density of one beam results in a classical electromagnetic interaction on the particles in the other beam. This very nonlinear space charge force, caled the beam-beam force, limits the total circulating charge and, thereby, the ultimate performance of the colliding ring system. The basic nature of the beam-beam force is discussed, indicating how it is quite different in the case of continuous beams, which cross each other at an angle as compared to the case of bunched beams which collide head-on. Some experimental observations on the beam-beam interaction in proton-proton and electron-positron beams are then reviewed and interpreted. An important aspect of the beam-beam problem in storage rings is to determine at what point in the analysis of the particle dynamics is it relevant to bring in the concepts of stochasticity, slow diffusion, and resonance overlap. These ideas are briefly discussed.

  14. Funnel cone for focusing intense ion beams on a target

    International Nuclear Information System (INIS)

    Bieniosek, F.M.; Henestroza, E.; Ni, P.

    2009-01-01

    We describe a funnel cone for concentrating an ion beam on a target. The cone utilizes the reflection characteristic of ion beams on solid walls to focus the incident beam andincrease beam intensity on target. The cone has been modeled with the TRIM code. A prototype has been tested and installed for use in the 350-keV K+ NDCX target chamber.

  15. Study of conditions and effect factors for positron-emitting radiopharmaceuticals production

    International Nuclear Information System (INIS)

    Wang Mingfang; Tang Ganghua; Huang Zuhan; Gan Manquan; Luo Lei

    2002-01-01

    Objective: To probe the conditions and effect factors of the positron-emitting radionuclides production and the radiopharmaceuticals synthesis. Methods: The 18 F-F - and 13 N-NOx - were produced by 18 O(p,n) 18 F and 16 O(p, α) 13 N nuclear reaction in PET trace Cyclotron, respectively. The 2-deoxy-2-[ 18 F]-fluoro-D-glucose ( 18 F-FDG) was synthesized by direct nucleophilic exchange on 4-(4-methylpiperidinyl) pyridinium resin. The 13 N-NOx - in target water was reduced by Devard's alloy to prepare 13 N-ammonia. At the same time, the effect of the abundance and purity of target water, the irradiation time, and the proton beam current on the productions of positron-emitting radionuclides and the radiopharmaceuticals was studied. Results: While the resistivity of water was less than 10 MΩ·cm, the yields of 18 F-FDG and 13 N - ammonia were less than 9.5% and 38.2%, respectively. The yield of 18 F-FDG was more than 20% by using high abundance of 18 O-water above 50%. When proton beam current was from 5μA to 35μA, the yields of 18 F-F - and 13 N-Nox - were increased with the increment of the proton beam current. During irradiation, the yield of 13 N-Nox - was increased at a rate of 1.2 GBq/min within 20 min, but yield of 13 N-NOx - was only 0.1 GBq/min after 30 min. Furthermore, the yield of 18 F-F - was increased at a rate of 1.1 GBq/min within 60 min, and was less than 0.68 GBq/min after 120 min. Conclusions: The purity of target water and the proton beam current were main factors for the production of the positron-emitting radionuclides and the synthesis of radiopharmaceuticals. When the resistivity of target water was above 15 MΩ·cm and the irradiation time was one half-life of positron-emitting nuclides, the higher yields of 18 F-F - and 13 N-NOx - were obtained by using 25 μA-35 μA proton beam current bombarding the 18 O-water and 16 O-water, respectively, also, the higher yields of the radiopharmaceutical were given

  16. Thick-target-method study of Mα β x-ray production cross sections of Pb and Bi impacted by positrons up to 9 keV

    Science.gov (United States)

    Wu, Y.; Liang, Y.; Xu, M. X.; Yuan, Y.; Chang, C. H.; Qian, Z. C.; Wang, B. Y.; Kuang, P.; Zhang, P.

    2018-03-01

    Atomic M -shell x-ray production cross sections induced by positrons near the threshold energy have been presented in this paper. In the experiment, online monitoring technology, which utilizes a high-purity germanium detector to record the annihilation photons emitted from the pure thick target impacted by positrons, was developed to obtain the accurate number of the incident positrons. The effects of the multiple scattering of incident positrons, from the bremsstrahlung and annihilation photons and other secondary particles on the experimental characteristic x-ray yield, were eliminated by Monte Carlo simulation in combination with theoretical integral calculation. The Tikhonov regularization method was adopted to handle the ill-posed inverse problem involved in the thick-target method, i.e., x-ray production cross sections by the corrected characteristic x-ray yield. Experimental results of Mα β x-ray production cross sections for Pb and Bi impacted by 6-9-keV positrons were compared with the corresponding values predicted by the distorted-wave Born approximation (DWBA). Good agreement was found between the two. Moreover, we have presented the experimental results on the ratios of the Mα β x-ray production cross sections by electron impact in the literature to that by 6-9-keV positron impact in this work. They were also in accordance with the theoretical ratios calculated by the predictions of DWBA theory.

  17. Commissioning the beam diagnostics for the PEP-II B Factory

    International Nuclear Information System (INIS)

    Fisher, A.S.; Alzofon, D.; Collins, B.

    1998-06-01

    PEP-II is a 2.2-km-circumference collider with a 2.1-A, 3.1-GeV positron ring (the Low-Energy Ring) 1 m above a 1-A, 9-GeV electron ring (the High-Energy Ring); both rings are designed for a maximum current of 3 A. The authors describe the beam diagnostics and present measurements from HER commissioning. The beam profile is measured using near-UV synchrotron light extracted by grazing-incidence mirrors that must withstand up to 200 W/cm. Normally 1,658 of the 3,492 buckets will be filled, and the charge must be equal within 2%. To measure the charge in each bucket, the sum signal from a set of 4 pickup buttons is digitized and averaged over 256 samples per bucket in every 60-Hz interval. The sum is them normalized to the ring current, measured by a DC current transformer. The 300 beam-position monitors per ring are multiplexed to share 171 processor modules, which use DPSs for recording positions over 1,024 turns and for calibration. For both diagnostics and machine protection, 100 photomultipliers with fused-silica Cherenkov radiators measure beam losses and can trigger a beam abort in case of high loss. For the ring tunes, signals from a set of 4 pickup buttons are combined into horizontal, vertical, and sum signals. Two signals are selected and downconverted into the range of a 10-MHz, 2-channel, programmable, DSP-based spectrum analyzer, connected over ethernet to the control room

  18. Adiabatic matching section for plasma accelerated beams

    Directory of Open Access Journals (Sweden)

    Klaus Floettmann

    2014-05-01

    Full Text Available An adiabatic matching section is discussed as option to control the divergence and emittance growth of a beam exiting a plasma channel. Based on a general analytical solution of a focusing channel with varying focusing strength, a focusing profile is proposed which allows for a fast expansion of the beam size while keeping the emittance growth minimal. The solution is also applicable to other cases, e.g., the matching of a positron source to the downstream accelerating section, which are, however, not discussed in this contribution.

  19. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  20. Study of radiation damage in metals by positron annihilation

    International Nuclear Information System (INIS)

    Gauster, W.B.

    1977-01-01

    Positron annihilation is a sensitive technique for probing defects in metals and it has recently been shown to be a valuable tool for the study of radiation damage. After an introduction to the three basic experimental methods (angular correlation, Doppler broadening, and lifetime measurements), the interaction of positrons with lattice defects is reviewed. Results for the annealing of damage after low temperature irradiation are used to show that positron annihilation has provided new information on annealing kinetics. The role of positron techniques in characterizing complex defect structures resulting from high-temperature neutron irradiation is reviewed and the possible utility of positron annihilation as a nondestructive monitor of property changes is pointed out

  1. Ultrarelativistic electron and positron radiation in planar channeling

    International Nuclear Information System (INIS)

    Kalashnikov, N.P.; Olchack, A.S.

    1980-01-01

    The coherent electromagnetic radiation from channeling electrons and positrons is given by similar expression. However for the channeling positrons the close collisions are suppressed due to the fact that the positron wave function is exponentially small near the atoms of the crystal lattice. It follows that the coherent bremsstrahlung decreases for the channeling positrons. We have investigated the ultrarelativistic channeling electron and positron radiations, connected with the electromagnetic transitions from the continuum spectrum states to the quasi-bound spectrum states and between the different quasi-bound spectrum states. The radiation probabilities are calculated by using the model continuum planar potential. It is shown that the radiation from the channeling electrons is several orders of magnitude larger than the positron radiation, while the electron and positron radiation have similar characteristics such as frequency limitation and angular distribution of the radiation. (orig.)

  2. Theory of positrons in solids and on solid surfaces

    International Nuclear Information System (INIS)

    Puska, M.J.; Nieminen, R.M.

    1994-01-01

    Various experimental methods based on positron annihilation have evolved into important tools for researching the structure and properties of condensed matter. In particular, positron techniques are useful for the investigation of defects in solids and for the investigation of solid surfaces. Experimental methods need a comprehensive theory for a deep, quantitative understanding of the results. In the case of positron annihilation, the relevant theory includes models needed to describe the positron states as well as the different interaction processes in matter. In this review the present status of the theory of positrons in solids and on solid surfaces is given. The review consists of three main parts describing (a) the interaction processes, (b) the theory and methods for calculating positron states, and (c) selected recent results of positron studies of condensed matter

  3. Positron simulations of defects in tungsten containing hydrogen and helium

    International Nuclear Information System (INIS)

    Troev, T.; Popov, E.; Staikov, P.; Nankov, N.; Yoshiie, T.

    2009-01-01

    An understanding of the behavior of defects containing hydrogen or helium in tungsten is an important issue. Here the properties of defects in tungsten containing hydrogen or helium atoms have been investigated by model positron lifetime quantum-mechanical simulations. The electron and positron wave functions have been obtained in the local density approximation to the two-component density-functional theory. The calculated values of the positron lifetime correlate with the magnitude of the electron density. The vacancy-clusters without hydrogen or helium are active positron traps. The lattice relaxation of atoms around vacancy reduces the effective vacancy volume and decrease the positron lifetime at a vacancy. The hydrogen and helium atoms are trapped in tungsten by lattice vacancies and nano-voids. It was established that positron lifetime depends on the density of gas atoms inside the nano-void. Hydrogen and helium presence in the larger nano-voids considerably decrease the positron lifetime.

  4. Probing Positron Cooling in Noble Gases via Annihilation γ Spectra.

    Science.gov (United States)

    Green, D G

    2017-11-17

    γ spectra for positron annihilation in noble-gas atoms are calculated using many-body theory for positron momenta up to the positronium-formation threshold. These data are used, together with time-evolving positron-momentum distributions determined in the preceding Letter [Phys. Rev. Lett. 119, 203403 (2017)PRLTAO0031-9007], to calculate the time-varying γ spectra produced during positron cooling in noble gases. The γ spectra and their S[over ¯] and W[over ¯] shape parameters are shown to be sensitive probes of the time evolution of the positron momentum distribution and thus provide a means of studying positron cooling that is complementary to positron lifetime spectroscopy.

  5. Beam diagnostics

    International Nuclear Information System (INIS)

    Bogaty, J.; Clifft, B.E.; Zinkann, G.P.; Pardo, R.C.

    1995-01-01

    The ECR-PII injector beam line is operated at a fixed ion velocity. The platform high voltage is chosen so that all ions have a velocity of 0.0085c at the PII entrance. If a previous tune configuration for the linac is to be used, the beam arrival time must be matched to the previous tune as well. A nondestructive beam-phase pickup detector was developed and installed at the entrance to the PII linac. This device provides continuous phase and beam current information and allows quick optimization of the beam injected into PII. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum interface where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam-induced radiofrequency signals are summed against an offset frequency generated by our master oscillator. The resulting kilohertz difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop which stabilizes phase readings if beam is unstable. The other channel uses a linear full wave active rectifier circuit which converts kilohertz sine wave signal amplitude to a D.C. voltage representing beam current. A prototype set of electronics is now in use with the detector and we began to use the system in operation to set the arrival beam phase. A permanent version of the electronics system for the phase detector is now under construction. Additional nondestructive beam intensity and phase monitors at the open-quotes Boosterclose quotes and open-quotes ATLASclose quotes linac sections are planned as well as on some of the high-energy beam lines. Such a monitor will be particularly useful for FMA experiments where the primary beam hits one of the electric deflector plates

  6. Relativistic Shear Flow between Electron-Ion and Electron-Positron Plasmas and Astrophysical Applications

    Science.gov (United States)

    Liang, Edison; Fu, Wen; Böttcher, Markus

    2017-10-01

    We present particle-in-cell simulation results of relativistic shear boundary layers between electron-ion and electron-positron plasmas and discuss their potential applications to astrophysics. Specifically, we find that in the case of a fast electron-positron spine surrounded by a slow-moving or stationary electron-ion sheath, lepton acceleration proceeds in a highly anisotropic manner due to electromagnetic fields created at the shear interface. While the highest-energy leptons still produce a beaming pattern (as seen in the quasi-stationary frame of the sheath) of order 1/Γ, where Γ is the bulk Lorentz factor of the spine, for lower-energy particles, the beaming is much less pronounced. This is in stark contrast to the case of pure electron-ion shear layers, in which anisotropic particle acceleration leads to significantly narrower beaming patterns than 1/Γ for the highest-energy particles. In either case, shear-layer acceleration is expected to produce strongly angle-dependent lepton (hence, emanating radiation) spectra, with a significantly harder spectrum in the forward direction than viewed from larger off-axis angles, much beyond the regular Doppler boosting effect from a co-moving isotropic lepton distribution. This may solve the problem of the need for high (and apparently arbitrarily chosen) minimum Lorentz factors of radiating electrons, often plaguing current blazar and GRB jet modeling efforts.

  7. Relativistic Shear Flow between Electron–Ion and Electron–Positron Plasmas and Astrophysical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Edison; Fu, Wen [Rice University, Houston, TX 77005 (United States); Böttcher, Markus [North-West University, Potchefstroom, 2520 (South Africa)

    2017-10-01

    We present particle-in-cell simulation results of relativistic shear boundary layers between electron–ion and electron–positron plasmas and discuss their potential applications to astrophysics. Specifically, we find that in the case of a fast electron–positron spine surrounded by a slow-moving or stationary electron–ion sheath, lepton acceleration proceeds in a highly anisotropic manner due to electromagnetic fields created at the shear interface. While the highest-energy leptons still produce a beaming pattern (as seen in the quasi-stationary frame of the sheath) of order 1/Γ, where Γ is the bulk Lorentz factor of the spine, for lower-energy particles, the beaming is much less pronounced. This is in stark contrast to the case of pure electron–ion shear layers, in which anisotropic particle acceleration leads to significantly narrower beaming patterns than 1/Γ for the highest-energy particles. In either case, shear-layer acceleration is expected to produce strongly angle-dependent lepton (hence, emanating radiation) spectra, with a significantly harder spectrum in the forward direction than viewed from larger off-axis angles, much beyond the regular Doppler boosting effect from a co-moving isotropic lepton distribution. This may solve the problem of the need for high (and apparently arbitrarily chosen) minimum Lorentz factors of radiating electrons, often plaguing current blazar and GRB jet modeling efforts.

  8. Properties of the electron cloud in a high-energy positron and electron storage ring

    Directory of Open Access Journals (Sweden)

    K. C. Harkay

    2003-03-01

    Full Text Available Low-energy, background electrons are ubiquitous in high-energy particle accelerators. Under certain conditions, interactions between this electron cloud and the high-energy beam can give rise to numerous effects that can seriously degrade the accelerator performance. These effects range from vacuum degradation to collective beam instabilities and emittance blowup. Although electron-cloud effects were first observed two decades ago in a few proton storage rings, they have in recent years been widely observed and intensely studied in positron and proton rings. Electron-cloud diagnostics developed at the Advanced Photon Source enabled for the first time detailed, direct characterization of the electron-cloud properties in a positron and electron storage ring. From in situ measurements of the electron flux and energy distribution at the vacuum chamber wall, electron-cloud production mechanisms and details of the beam-cloud interaction can be inferred. A significant longitudinal variation of the electron cloud is also observed, due primarily to geometrical details of the vacuum chamber. Such experimental data can be used to provide realistic limits on key input parameters in modeling efforts, leading ultimately to greater confidence in predicting electron-cloud effects in future accelerators.

  9. Properties of the electron cloud in a high-energy positron and electron storage ring

    International Nuclear Information System (INIS)

    Harkay, K.C.; Rosenberg, R.A.

    2003-01-01

    Low-energy, background electrons are ubiquitous in high-energy particle accelerators. Under certain conditions, interactions between this electron cloud and the high-energy beam can give rise to numerous effects that can seriously degrade the accelerator performance. These effects range from vacuum degradation to collective beam instabilities and emittance blowup. Although electron-cloud effects were first observed two decades ago in a few proton storage rings, they have in recent years been widely observed and intensely studied in positron and proton rings. Electron-cloud diagnostics developed at the Advanced Photon Source enabled for the first time detailed, direct characterization of the electron-cloud properties in a positron and electron storage ring. From in situ measurements of the electron flux and energy distribution at the vacuum chamber wall, electron-cloud production mechanisms and details of the beam-cloud interaction can be inferred. A significant longitudinal variation of the electron cloud is also observed, due primarily to geometrical details of the vacuum chamber. Such experimental data can be used to provide realistic limits on key input parameters in modeling efforts, leading ultimately to greater confidence in predicting electron-cloud effects in future accelerators.

  10. Low energy positron interactions with uracil—Total scattering, positronium formation, and differential elastic scattering cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, E. K.; Boadle, R. A.; Machacek, J. R.; Makochekanwa, C.; Sullivan, J. P. [ARC Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra 0200 (Australia); Chiari, L. [ARC Centre for Antimatter-Matter Studies, Flinders University, GPO Box 2100, Adelaide, 5001 SA (Australia); Buckman, S. J., E-mail: Stephen.buckman@anu.edu.au [ARC Centre for Antimatter-Matter Studies, Research School of Physics and Engineering, The Australian National University, Canberra 0200 (Australia); Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur (Malaysia); Brunger, M. J. [ARC Centre for Antimatter-Matter Studies, Flinders University, GPO Box 2100, Adelaide, 5001 SA (Australia); Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur (Malaysia); Garcia, G. [Instituto de Fısica Fundamental, Consejo Superior de Investigationes Cientıficas (CSIC), Serrano 113-bis, E-28006 Madrid (Spain); Blanco, F. [Departamento de Fısica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Ingolfsson, O. [Department of Chemistry, Science Institute, University of Iceland, Reykjavík 107 (Iceland)

    2014-07-21

    Measurements of the grand total and total positronium formation cross sections for positron scattering from uracil have been performed for energies between 1 and 180 eV, using a trap-based beam apparatus. Angular, quasi-elastic differential cross section measurements at 1, 3, 5, 10, and 20 eV are also presented and discussed. These measurements are compared to existing experimental results and theoretical calculations, including our own calculations using a variant of the independent atom approach.

  11. Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET Imaging Using GEANT4 Toolkit

    Directory of Open Access Journals (Sweden)

    Mohsen Mashayekhi

    2015-05-01

    Application of a magnetic field perpendicular to the positron diffusion plane prevented the scattering of positrons, and consequently, improved the intrinsic spatial resolution of PET imaging, caused by positron range effects.

  12. Clinical applications with the HIDAC positron camera

    Science.gov (United States)

    Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.

    1988-06-01

    A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation

  13. Proceedings of the 3rd workshop on ion-beam-applied biology

    International Nuclear Information System (INIS)

    Matsuhashi, Shinpei; Suzui, Nobuo; Ishioka, Noriko S.

    2005-09-01

    In order to encourage research on biological application using ion beam at TIARA, we have had the workshop on ion beam applied biology at JAERI Takasaki every year since 2002. The 3rd workshop titled 'Future development of plant research using the positron imaging method - Understanding the plant functions through visualization images-' is held this year. The main topics of this workshop are introduction of the latest studies on the assimilation and transportation of nutrients by plant using positron imaging method. Further, related technologies of the positron imaging and prospect of positron imaging for is discussed. We hope this workshop popularizes positron imaging technology for plants, accelerates cooperation between industries, universities and governmental institutes and contributes future projects of understanding of the physiological functions of plants using the positron imaging method. This workshop was held on September 29th 2004, hosted by JAERI Takasaki and cooperated by The Japan Radioisotope Association, Japanese Society of Soil Science and Plant Nutrition. The Japanese Society of Plant Physiologists, Atomic Energy Society of Japan, The Japanese Society of Nuclear and Radiochemical Science and The Ion Beam Breeding Society. There were 85 participants from not only universities and laboratories but also private company developing the environment conservation technology, so on. Highly qualified presentations were given on biological studies with ion beam, on analysis of plant functions using the positron imaging method and on supporting technology for the positron imaging monitoring. Progress in the elucidation of plant functions is expected to develop the technologies for production of safe provisions and conservation of environment with plant. The 14 of the presented papers are indexed individually. (J.P.N.)

  14. Expectations for prospective applications of new beam technology to atomic energy research

    International Nuclear Information System (INIS)

    Tomimasu, Takio; Yamazaki, Tetsuo; Tanaka, Ryuichi; Tanigawa, Shoichiro; Konashi, Kenji; Mizumoti, Motoharu.

    1991-01-01

    Recently, the new beam technology based on high energy electron beam, for example free electron laser, low speed positrons and so on, has developed remarkably. Moreover, also in the field of ion beams, toward the utilization of further high level, the plans of using micro-beams, heightening energy, increasing electric current and so on are in progress. In near future, it is expected that the advanced application of such new beam technology expands more and more in the fields of materials, physical properties, isotope separation, biology, medical science, medical treatment and so on. In this report, placing emphasis on the examples of application, the development and application of new beam technology are described. Takasaki ion accelerators for advanced radiation application in Japan Atomic Energy Research Institute, the generation of low speed positrons and the utilization for physical property studies, the annihilation treatment of long life radioactive nuclides, and the generation of free electron laser and its application are reported. (K.I.)

  15. Tomography by positrons: methodology and applications

    International Nuclear Information System (INIS)

    Kellershohn, C.; Comar, D.

    1979-01-01

    Whereas gamma tomography (single photon) provides a new and fruitful dimension to conventional nuclear medicine, tomography by positrons makes possible a novel approach to the in-vivo analysis of fundamental and biological processes. The main object of both is the cross sectional representation of the distribution of a radioactive marker injected into the organism and in comparison with conventional detectors (gamma cameras and scintigraphs) they afford a much improved accuracy in position finding. The characteristics of these two methods may be represented diagrammatically by comparing their respective advantages and drawbacks. The method of fabricating positron emitting radioelements, the preparation of the radopharmeutics and the detection appliances are then examined in turn. To conclude, the medical uses: anatomical autoradiographs, as well as physiological, metabolic and pharmacological autoradiographs are described [fr

  16. Positron annihilation characterization of nanostructured ferritic alloys

    International Nuclear Information System (INIS)

    Alinger, M.J.; Glade, S.C.; Wirth, B.D.; Odette, G.R.; Toyama, T.; Nagai, Y.; Hasegawa, M.

    2009-01-01

    Nanostructured ferritic alloys (NFAs) were produced by mechanically alloying Fe-14Cr-3W-0.4Ti and 0.25Y 2 O 3 (wt%) powders followed by hot isostatic pressing consolidation at 850, 1000 and 1150 deg. C. Positron annihilation lifetime and orbital momentum spectroscopy measurements are in qualitative agreement with small angle neutron scattering, transmission electron microscopy and atom probe tomography observations, indicating that up to 50% of the annihilations occur at high densities of Y-Ti-O enriched nm-scale features (NFs). Some annihilations may also occur in small cavities. In Y-free control alloys, that do not contain NFs, positrons primarily annihilate in the Fe-Cr matrix and at features such as dislocations, while a small fraction annihilate in large cavities or Ar bubbles.

  17. Cold Positrons from Decaying Dark Matter

    Energy Technology Data Exchange (ETDEWEB)

    Boubekeur, Lotfi [Universitate de Valencia (Spain); Dodelson, Scott [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Vives, Oscar [Universitate de Valencia (Spain)

    2012-11-01

    Many models of dark matter contain more than one new particle beyond those in the Standard Model. Often heavier particles decay into the lightest dark matter particle as the Universe evolves. Here we explore the possibilities that arise if one of the products in a (Heavy Particle) $\\rightarrow$ (Dark Matter) decay is a positron, and the lifetime is shorter than the age of the Universe. The positrons cool down by scattering off the cosmic microwave background and eventually annihilate when they fall into Galactic potential wells. The resulting 511 keV flux not only places constraints on this class of models but might even be consistent with that observed by the INTEGRAL satellite.

  18. Positron scattering and annihilation from hydrogenlike ions

    International Nuclear Information System (INIS)

    Novikov, S.A.; Bromley, M.W.J.; Mitroy, J.

    2004-01-01

    The Kohn variational method is used with a configuration-interaction-type wave function to determine the J=0 and J=1 phase shifts and annihilation parameter Z eff for positron-hydrogenic ion scattering. The phase shifts are within 1-2% of the best previous calculations. The values of Z eff are small and do not exceed unity for any of the momenta considered. At thermal energies Z eff is minute with a value of order 10 -50 occurring for He + at k=0.05a 0 -1 . In addition to the variational calculations, analytic expressions for the phase shift and annihilation parameters within the Coulomb wave Born approximation are derived and used to help elucidate the dynamics of positron collisions with positive ions

  19. Image reconstruction methods in positron tomography

    International Nuclear Information System (INIS)

    Townsend, D.W.; Defrise, M.

    1993-01-01

    In the two decades since the introduction of the X-ray scanner into radiology, medical imaging techniques have become widely established as essential tools in the diagnosis of disease. As a consequence of recent technological and mathematical advances, the non-invasive, three-dimensional imaging of internal organs such as the brain and the heart is now possible, not only for anatomical investigations using X-ray but also for studies which explore the functional status of the body using positron-emitting radioisotopes. This report reviews the historical and physical basis of medical imaging techniques using positron-emitting radioisotopes. Mathematical methods which enable three-dimensional distributions of radioisotopes to be reconstructed from projection data (sinograms) acquired by detectors suitably positioned around the patient are discussed. The extension of conventional two-dimensional tomographic reconstruction algorithms to fully three-dimensional reconstruction is described in detail. (orig.)

  20. Positron emission tomography in movement disorders

    International Nuclear Information System (INIS)

    Martin, W.R.W.

    1985-01-01

    Positron emission tomography provides a method for the quantitation of regional function within the living human brain. Studies of cerebral metabolism and blood flow in patients with Huntington's disease, Parkinson's disease and focal dystonia have revealed functional abnormalities within substructures of the basal ganglia. Recent developments permit assessment of both pre-synaptic and post-synaptic function ion dopaminergic pathways. These techniques are now being applied to studies of movement disorders in human subjects

  1. Cosmic-ray Positrons from Millisecond Pulsars

    Science.gov (United States)

    Venter, C.; Kopp, A.; Harding, A. K.; Gonthier, P. L.; Büsching, I.

    2015-07-01

    Observations by the Fermi Large Area Telescope of γ-ray millisecond pulsar (MSP) light curves imply copious pair production in their magnetospheres, and not exclusively in those of younger pulsars. Such pair cascades may be a primary source of Galactic electrons and positrons, contributing to the observed enhancement in positron flux above ∼10 GeV. Fermi has also uncovered many new MSPs, impacting Galactic stellar population models. We investigate the contribution of Galactic MSPs to the flux of terrestrial cosmic-ray electrons and positrons. Our population synthesis code predicts the source properties of present-day MSPs. We simulate their pair spectra invoking an offset-dipole magnetic field. We also consider positrons and electrons that have been further accelerated to energies of several TeV by strong intrabinary shocks in black widow (BW) and redback (RB) systems. Since MSPs are not surrounded by pulsar wind nebulae or supernova shells, we assume that the pairs freely escape and undergo losses only in the intergalactic medium. We compute the transported pair spectra at Earth, following their diffusion and energy loss through the Galaxy. The predicted particle flux increases for non-zero offsets of the magnetic polar caps. Pair cascades from the magnetospheres of MSPs are only modest contributors around a few tens of GeV to the lepton fluxes measured by the Alpha Magnetic Spectrometer, PAMELA, and Fermi, after which this component cuts off. The contribution by BWs and RBs may, however, reach levels of a few tens of percent at tens of TeV, depending on model parameters.

  2. COSMIC-RAY POSITRONS FROM MILLISECOND PULSARS

    Energy Technology Data Exchange (ETDEWEB)

    Venter, C.; Kopp, A.; Büsching, I. [Centre for Space Research, North-West University, Potchefstroom Campus, Private Bag X6001, Potchefstroom 2520 (South Africa); Harding, A. K. [Astrophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Gonthier, P. L. [Hope College, Department of Physics, Holland, MI (United States)

    2015-07-10

    Observations by the Fermi Large Area Telescope of γ-ray millisecond pulsar (MSP) light curves imply copious pair production in their magnetospheres, and not exclusively in those of younger pulsars. Such pair cascades may be a primary source of Galactic electrons and positrons, contributing to the observed enhancement in positron flux above ∼10 GeV. Fermi has also uncovered many new MSPs, impacting Galactic stellar population models. We investigate the contribution of Galactic MSPs to the flux of terrestrial cosmic-ray electrons and positrons. Our population synthesis code predicts the source properties of present-day MSPs. We simulate their pair spectra invoking an offset-dipole magnetic field. We also consider positrons and electrons that have been further accelerated to energies of several TeV by strong intrabinary shocks in black widow (BW) and redback (RB) systems. Since MSPs are not surrounded by pulsar wind nebulae or supernova shells, we assume that the pairs freely escape and undergo losses only in the intergalactic medium. We compute the transported pair spectra at Earth, following their diffusion and energy loss through the Galaxy. The predicted particle flux increases for non-zero offsets of the magnetic polar caps. Pair cascades from the magnetospheres of MSPs are only modest contributors around a few tens of GeV to the lepton fluxes measured by the Alpha Magnetic Spectrometer, PAMELA, and Fermi, after which this component cuts off. The contribution by BWs and RBs may, however, reach levels of a few tens of percent at tens of TeV, depending on model parameters.

  3. Positron studies of defected metals, metallic surfaces

    International Nuclear Information System (INIS)

    Bansil, A.

    1991-01-01

    Specific problems proposed under this project included the treatment of electronic structure and momentum density in various disordered and defected systems. Since 1987, when the new high-temperature superconductors were discovered, the project focused extensively on questions concerning the electronic structure and Fermiology of high-T c superconductors, in particular, (i) momentum density and positron experiments, (ii) angle-resolved photoemission intensities, (iii) effects of disorder and substitutions in the high-T c 's

  4. Elliptical beams.

    Science.gov (United States)

    Bandres, Miguel A; Gutiérrez-Vega, Julio C

    2008-12-08

    A very general beam solution of the paraxial wave equation in elliptic cylindrical coordinates is presented. We call such a field an elliptic beam (EB). The complex amplitude of the EB is described by either the generalized Ince functions or the Whittaker-Hill functions and is characterized by four parameters that are complex in the most general situation. The propagation through complex ABCD optical systems and the conditions for square integrability are studied in detail. Special cases of the EB are the standard, elegant, and generalized Ince-Gauss beams, Mathieu-Gauss beams, among others.

  5. Advances in positron and electron scattering*

    Science.gov (United States)

    Limão-Vieira, Paulo; García, Gustavo; Krishnakumar, E.; Petrović, Zoran; Sullivan, James; Tanuma, Hajime

    2016-10-01

    The topical issue on Advances in Positron and Electron Scattering" combines contributions from POSMOL 2015 together with others devoted to celebrate the unprecedented scientific careers of our loyal colleagues and trusted friends Steve Buckman (Australian National University, Australia) and Michael Allan (University of Fribourg, Switzerland) on the occasion of their retirements. POSMOL 2015, the XVIII International Workshop on Low-Energy Positron and Positronium Physics and the XIX International Symposium on Electron-Molecule Collisions and Swarms, was held at Universidade NOVA de Lisboa, Lisboa, Portugal, from 17-20 July 2015. The international workshop and symposium allowed to achieve a very privileged forum of sharing and developing our scientific expertise on current aspects of positron, positronium and antiproton interactions with electrons, atoms, molecules and solid surfaces, and related topics, as well as electron interactions with molecules in both gaseous and condensed phases. Particular topics include studies of electron interactions with biomolecules, electron induced surface chemistry and the study of plasma processes. Recent developments in the study of swarms are also fully addressed.

  6. Dark matter "transporting" mechanism explaining positron excesses

    Science.gov (United States)

    Kim, Doojin; Park, Jong-Chul; Shin, Seodong

    2018-04-01

    We propose a novel mechanism to explain the positron excesses, which are observed by satellite-based telescopes including PAMELA and AMS-02, in dark matter (DM) scenarios. The novelty behind the proposal is that it makes direct use of DM around the Galactic Center where DM populates most densely, allowing us to avoid tensions from cosmological and astrophysical measurements. The key ingredients of this mechanism include DM annihilation into unstable states with a very long laboratory-frame life time and their "retarded" decay near the Earth to electron-positron pair(s) possibly with other (in)visible particles. We argue that this sort of explanation is not in conflict with relevant constraints from big bang nucleosynthesis and cosmic microwave background. Regarding the resultant positron spectrum, we provide a generalized source term in the associated diffusion equation, which can be readily applicable to any type of two-"stage" DM scenarios wherein production of Standard Model particles occurs at completely different places from those of DM annihilation. We then conduct a data analysis with the recent AMS-02 data to validate our proposal.

  7. Positron annihilation in gamma-ray bursts

    Science.gov (United States)

    Harding, Alice K.

    1990-01-01

    Emission features appear at energies of 350 to 450 keV in the spectra of a number of gamma ray burst sources. These features were interpreted as electron-positron annihilation lines, redshifted by the gravitational field near the surface of a neutron star. Evidence that gamma ray bursts originate at neutron stars with magnetic field strengths of approx. 10(exp 12) Gauss came from recent observations of cyclotron scattering harmonics in the spectra of two bursts. Positrons could be produced in gamma ray burst sources either by photon-photon pair production or by one-photon pair production in a strong magnetic field. The annihilation of positrons is affected by the presence of a strong neutron star magnetic field in several ways. The relaxation of transverse momentum conservation causes an intrinsic broadening of the two-photon annihilation line and there is a decrease in the annihilation cross section below the free-space value. An additional channel for one-photon annihilation also becomes possible in high magnetic fields. The physics of pair production and annihilation near strongly magnetized neutron stars will be reviewed. Results from a self-consistent model for non-thermal synchrotron radiation and pair annihilation are beginning to identify the conditions required to produce observable annihilation features from strongly magnetized plasmas.

  8. Positron Cooling and Annihilation in Noble Gases.

    Science.gov (United States)

    Green, D G

    2017-11-17

    Positron cooling and annihilation in room temperature noble gases is simulated using accurate scattering and annihilation cross sections calculated with many-body theory, enabling the first simultaneous probing of the energy dependence of the scattering and annihilation cross sections. A strikingly small fraction of positrons is shown to survive to thermalization: ∼0.1 in He, ∼0 in Ne, ∼0.15 in Ar, ∼0.05 in Kr, and ∼0.01 in Xe. For Xe, the time-varying annihilation rate Z[over ¯]_{eff}(τ) is shown to be highly sensitive to the depletion of the momentum distribution due to annihilation, conclusively explaining the long-standing discrepancy between gas-cell and trap-based measurements. Overall, the use of the accurate atomic data gives Z[over ¯]_{eff}(τ) in close agreement with experiment for all noble gases except Ne, the experiment for which is proffered to have suffered from incomplete knowledge of the fraction of positrons surviving to thermalization and/or the presence of impurities.

  9. Positron emitting radionuclides for South Africa

    International Nuclear Information System (INIS)

    Wynchbank, S.; Van der Walt, T.N.; Sharpey-Shafer, J.

    2004-01-01

    Full text: In South Africa there are currently two projects underway to supply and utilise positron emitting radionuclides for imaging in clinical nuclear medicine facilities. The advantages and applications of such radio nuclides are numerous and well known. However the premier initial application will be to employ 1BF, at first in the compound fluorine-18 fluorodeoxyglucose ( 18 F)-FDG, for patients with cancers and neoplasms. The two projects are sited at iThemba LABS, where production of a generator supplying 66 Ga and the provision of ( 18 F]-FDG, are in an advanced state of planning; the former already fully financed by the Innovation Fund of the National Research Foundation. The two positron emitting radionuclides, 18 F and 68 Ge, will be produced using a cyclotron induced reaction on 1802 and Ga, respectively, at iThemba LABS. The 68 Ge/ 68 Ga generator consists of an anion exchanger loaded with 68 Ge, which decays to 68 Ga. The resulting radiopharmaceuticals, ( 18 F]-FDG and 68 Ga citrate, will be produced by the Radionuclide Production Group of iThemba LABS, using well described methods. However the structures and processes to be used in the generator to provide 68 Ga are novel and will be explained. Initially provision of the CBF]-FDG will be to selected clinical medicine facilities in the Western Cape and Gauteng. It should be noted that the logistical problems of providing this radiopharmaceutical (which are much complicated by its short half life of 109.7 min) to Gauteng, were shown to be surmountable in the 1970s, by a regular delivery of 18 F between Gauteng and Cape Town, after the advent of a commercial service using jet aircraft. The obvious requirement that there should be appropriate nuclear medicine facilities to image patients, at the sites to which the positron emitting radiopharmaceuticals will be supplied, has been addressed. Proposed solutions will be outlined, in terms of a dedicated positron emission tomography (PET) camera and a gamma

  10. Positron lifetime measurements on electron irradiated amorphous alloys

    International Nuclear Information System (INIS)

    Moser, P.; Hautojaervi, P.; Chamberod, A.; Yli-Kauppila, J.; Van Zurk, R.

    1981-08-01

    Great advance in understanding the nature of point defects in crystalline metals has been achieved by employing positron annihilation technique. Positrons detect vacancy-type defects and the lifetime value of trapped positrons gives information on the size of submicroscopic vacancy aglomerates and microvoids. In this paper it is shown that low-temperature electron irradiations can result in a considerable increase in the positron lifetimes in various amorphous alloys because of the formation of vacancy-like defects which, in addition of the pre-existing holes, are able to trap positrons. Studied amorphous alloys were Fe 80 B 20 , Pd 80 Si 20 , Cu 50 Ti 50 , and Fe 40 Ni 40 P 14 B 6 . Electron irradiations were performed with 3 MeV electrons at 20 K to doses around 10 19 e - /cm 2 . After annealing positron lifetime spectra were measured at 77 K

  11. Positron annihilation in the nuclear outflows of the Milky Way

    Science.gov (United States)

    Panther, Fiona H.; Crocker, Roland M.; Birnboim, Yuval; Seitenzahl, Ivo R.; Ruiter, Ashley J.

    2018-02-01

    Observations of soft gamma rays emanating from the Milky Way from SPI/INTEGRAL reveal the annihilation of ˜2 × 1043 positrons every second in the Galactic bulge. The origin of these positrons, which annihilate to produce a prominent emission line centred at 511 keV, has remained mysterious since their discovery almost 50 yr ago. A plausible origin for the positrons is in association with the intense star formation ongoing in the Galactic centre. Moreover, there is strong evidence for a nuclear outflow in the Milky Way. We find that advective transport and subsequent annihilation of positrons in such an outflow cannot simultaneously replicate the observed morphology of positron annihilation in the Galactic bulge and satisfy the requirement that 90 per cent of positrons annihilate once the outflow has cooled to 104 K.

  12. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2012-07-01

    Full Text Available positions of p zeros of intensity distributions on the Gaussian beam, resulting to a generation of TEMp0 beams where there are minimum losses. The LGBs are well-known family of exact orthogonal solutions of free-space paraxial wave equation in cylindrical...

  13. The effect of laser beam size in a zig-zag collimator on transverse ...

    Indian Academy of Sciences (India)

    The effect of size of a cooling laser beam in a zig-zag atomic beam collimator on transverse cooling of a krypton atomic beam is investigated. The simulation results show that discreteness in the interaction between the cooling laser beam and atomic beam, arising due to finite size and incidence angle of the cooling laser ...

  14. Positrons, Positronium, Positron and Positronium Complexes in Crystal. Features of Their Properties in Phonon Atmosphere

    Directory of Open Access Journals (Sweden)

    Eugene P. Prokopev

    2012-10-01

    Full Text Available The article, Basing on the example of ionic crystals shows that polarization of crystal framework by oppositely charged polarons (positronium atom (ps invokes the change of positronium binding energy and leads to the renormalization of electron and positron effective masses as well. Such interaction of electron and positronium atom of positron with optical phonons leads to additional repelling interaction, besides coulomb attractive. Furthermore, the existence of positronium atom with major and minor radius is possible in the atmosphere of crystal phonons.

  15. Beam diagnostics

    CERN Document Server

    Raich, U

    2008-01-01

    Most beam measurements are based on the electro-magnetic interaction of fields induced by the beam with their environment. Beam current transformers as well as beam position monitors are based on this principle. The signals induced in the sensors must be amplified and shaped before they are converted into numerical values. These values are further treated numerically in order to extract meaningful machine parameter measurements. The lecture introduces the architecture of an instrument and shows where in the treatment chain digital signal analysis can be introduced. Then the use of digital signal processing is presented using tune measurements, orbit and trajectory measurements as well as beam loss detection and longitudinal phase space tomography as examples. The hardware as well as the treatment algorithms and their implementation on Digital Signal Processors (DSPs) or in Field Programmable Gate Arrays (FPGAs) are presented.

  16. Positron Annihilation Spectroscopy study of minerals commonly found in shale

    Science.gov (United States)

    Alsleben, Helge; Ameena, Fnu; Bufkin, James; Chun, Joah; Quarles, C. A.

    2018-01-01

    Positron Annihilation Lifetime and Doppler Broadening spectroscopies are used to investigate twenty-three different rock-forming minerals that are commonly found in shale. Doppler Broadening provides information about the positron and positronium (Ps) trapping sites for comparison among the various minerals. Correlations of positron lifetime and Doppler Broadening are observed for different groups of minerals. Finally, Ps formation, or lack thereof, in the various minerals has been determined.

  17. Positron production using a 1.7 MV pelletron accelerator

    Science.gov (United States)

    Alcantara, K. F.; Crivelli, P.; Santos, A. C. F.

    2013-04-01

    We report the foremost phase of a fourth generation positron source, being constructed at the Federal University of Rio de Janeiro. Positron yields are reported by making use of the 19F(p,αe+e-)16O reaction, where the fluorine target is in the form of a CaF2 pellet. Positron production has been observed by detecting 511 keV annihilation gamma rays emerging from the irradiated CaF2 target.

  18. Investigation of highly activated materials by conventional positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Sabelova, V.; Petriska, M.; Slugen, V.; Krsjak, V.

    2013-01-01

    Positron annihilation process is helpful tool for material microstructure study. Many useful methods for detecting vacancies and their clusters in various alloys use its principle. Experimental procedure of positron source preparation (radioactive 22 Na) for these methods is difficult task. The unusual small sample dimensions of studied irradiated Eurofer 97 alloy form difficult conditions for its manufacturing. The unique sodium positron source proper preparation is confirmed by positron annihilation lifetime spectroscopy (PALS) and coincidence Doppler broadening spectroscopy (CDBS) in Paul Scherrer Institute in Switzerland. (authors)

  19. Absorbed dose in polymers during a positron annihilation experiment

    International Nuclear Information System (INIS)

    Suzuki, T.; Namito, Y.; Oki, Y.; Numajiri, M.; Miura, T.; Hirayama, H.; Kondo, K.; Ito, Y.

    1994-01-01

    A positron annihilation lifetime (PAL) technique has been recognized as being a useful method to study the characteristics of polymers. However, radiation effects due to positrons used as a probe have been raised as being a problem, since positrons emitted from 22 Na have sufficient energy to induce radiation damage in polymers. In this study, the radiation dose induced by positrons emitted from 22 Na was estimated for such polymers like polyethylenes and polypropylenes using the EGS4 code. The radiation damage during PAL measurements is also discussed. It has been shown that the calculated dose is consistent with that estimated from an empirical equation of the mass-attenuation coefficient. (author)

  20. Positron lifetime study of neutron-irradiated molybdenum

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Kumakura, Hiroaki; Doyama, Masao; Shiraishi, Kensuke.

    1978-01-01

    Annealing behavior of fast-neutron-irradiated molybdenum was studied by means of positron lifetime technique. It was found that Stage III annealing can be mainly identified as the vacancy migration process from the detailed analyses of data. The void growth after successive high temperature annealings was clearly detected through the changes of positron lifetime parameters. An attempt to analyse the size distribution of voids from positron lifetime spectra was presented, and discussions on the evaluation of void concentration from positron data are also given. (author)