WorldWideScience

Sample records for incident optical intensity

  1. New optical scheme for differential measurements of diffraction reflection intensity on X-radiation sliding incidence

    International Nuclear Information System (INIS)

    Golovin, A.L.; Mas', E.T.

    1989-01-01

    An X-ray optical scheme for differential measurements of X-ray diffraction under sliding incidence conditions is proposed and an attachment design realizng this scheme, using standard equipment, is described. The main feature of the scheme is the following: collimation according to the Bragg angle is carried out for the reflected beam rather than the incident one. Goniometers can be used from DRON, TRS, GS-5 and other spectrometers. The goniometer head carrying the sample is standard, it is a part of the DRON, TRS and DTS. The crystal analyzer is fixed on the attachment. The angular position of the crystal monochromator is controlled by an inductive sensor. The experimental differential curves of X-ray diffraction under conditions of sliding incidence, taken for a silicon crystal having the 111 orientation, are given as well

  2. Grazing Incidence Optics Technology

    Science.gov (United States)

    Ramsey, Brian; Smith, W. Scott; Gubarev, Mikhail; McCracken, Jeff

    2015-01-01

    This project is to demonstrate the capability to directly fabricate lightweight, high-resolution, grazing-incidence x-ray optics using a commercially available robotic polishing machine. Typical x-ray optics production at NASA Marshall Space Flight Center (MSFC) uses a replication process in which metal mirrors are electroformed on to figured and polished mandrels from which they are later removed. The attraction of this process is that multiple copies can be made from a single master. The drawback is that the replication process limits the angular resolution that can be attained. By directly fabricating each shell, errors inherent in the replication process are removed. The principal challenge now becomes how to support the mirror shell during all aspects of fabrication, including the necessary metrology to converge on the required mirror performance specifications. This program makes use of a Zeeko seven-axis computer-controlled polishing machine (see fig. 1) and supporting fabrication, metrology, and test equipment at MSFC. The overall development plan calls for proof-of-concept demonstration with relatively thick mirror shells (5-6 mm, fig. 2) which are straightforward to support and then a transition to much thinner shells (2-3 mm), which are an order of magnitude thinner than those used for Chandra. Both glass and metal substrates are being investigated. Currently, a thick glass shell is being figured. This has enabled experience to be gained with programming and operating the polishing machine without worrying about shell distortions or breakage. It has also allowed time for more complex support mechanisms for figuring/ polishing and metrology to be designed for the more challenging thinner shells. These are now in fabrication. Figure 1: Zeeko polishing machine.

  3. Grazing Incidence Neutron Optics

    Science.gov (United States)

    Gubarev, Mikhail V. (Inventor); Ramsey, Brian D. (Inventor); Engelhaupt, Darell E. (Inventor)

    2013-01-01

    Neutron optics based on the two-reflection geometries are capable of controlling beams of long wavelength neutrons with low angular divergence. The preferred mirror fabrication technique is a replication process with electroform nickel replication process being preferable. In the preliminary demonstration test an electroform nickel optics gave the neutron current density gain at the focal spot of the mirror at least 8 for neutron wavelengths in the range from 6 to 20.ANG.. The replication techniques can be also be used to fabricate neutron beam controlling guides.

  4. Plasma mirrors for ultrahigh-intensity optics

    International Nuclear Information System (INIS)

    Thaury, C.; Quere, F.; Levy, A.; Ceccotti, T.; Monot, P.; Bougeard, M.; Reau, F.; D'Oliveira, P.; Martin, PH.; Geindre, J.P.; Audebert, P.; Marjoribanks, R.; Marjoribanks, R.

    2007-01-01

    Specular reflection is one of the most fundamental processes of optics. At moderate light intensities generated by conventional light sources this process is well understood. But at those capable of being produced by modern ultrahigh-intensity lasers, many new and potentially useful phenomena arise. When a pulse from such a laser hits an optically polished surface, it generates a dense plasma that itself acts as a mirror, known as a plasma mirror (PM). PMs do not just reflect the remainder of the incident beam, but can act as active optical elements. Using a set of three consecutive PMs in different regimes, we significantly improve the temporal contrast of femtosecond pulses, and demonstrate that high-order harmonics of the laser frequency can be generated through two distinct mechanisms. A better understanding of these processes should aid the development of laser-driven atto-second sources for use in fields from materials science to molecular biology. (authors)

  5. Plasma mirrors for ultrahigh-intensity optics

    Energy Technology Data Exchange (ETDEWEB)

    Thaury, C; Quere, F; Levy, A; Ceccotti, T; Monot, P; Bougeard, M; Reau, F; D' Oliveira, P; Martin, PH [CEA, DSM, DRECAM, Serv Photons Atomes and Mol, F-91191 Gif Sur Yvette, (France); Geindre, J P; Audebert, P [Ecole Polytech, CNRS, Lab Utilisat Lasers Inst, F-91128 Palaiseau, (France); Marjoribanks, R [Univ Toronto, Dept Phys, Toronto, ON M5S 1A7, (Canada); Marjoribanks, R [Univ Toronto, Inst Opt Sci, Toronto, ON M5S 1A7, (Canada)

    2007-07-01

    Specular reflection is one of the most fundamental processes of optics. At moderate light intensities generated by conventional light sources this process is well understood. But at those capable of being produced by modern ultrahigh-intensity lasers, many new and potentially useful phenomena arise. When a pulse from such a laser hits an optically polished surface, it generates a dense plasma that itself acts as a mirror, known as a plasma mirror (PM). PMs do not just reflect the remainder of the incident beam, but can act as active optical elements. Using a set of three consecutive PMs in different regimes, we significantly improve the temporal contrast of femtosecond pulses, and demonstrate that high-order harmonics of the laser frequency can be generated through two distinct mechanisms. A better understanding of these processes should aid the development of laser-driven atto-second sources for use in fields from materials science to molecular biology. (authors)

  6. Optical design of grazing incidence toroidal grating monochromator

    International Nuclear Information System (INIS)

    Pouey, M.; Howells, M.R.; Takacs, P.Z.

    1982-01-01

    Design rules using geometrical optics and physical optics associated with the phase balancing method are discussed for stigmatic toroidal grazing incidence monochromators. To determine the optical performance of devices involving mirrirs and/or gratings, ray tracing programs using exact geometry are quite widely used. It is then desirable to have some way to infer the practical performance of an instrument from a spot diagram created by tracing a limited number of rays. We propose a first approach to this problem involving an estimation of the geometrical intensity distribution in the image plane and the corresponding line spread function. (orig.)

  7. Incidence of constipation in an intensive care unit

    OpenAIRE

    Guerra, Tatiana Lopes de Souza; Mendonça, Simone Sotero; Guimarães Marshall, Norma

    2013-01-01

    Objectives To evaluate the incidence of constipation in critical patients on enteral nutrition in a hospital intensive care unit and to correlate this incidence with the variables found for critical patients. Methods The present investigation was a retrospective analytical study conducted in the intensive care unit of Hospital Regional da Asa Norte (DF) via the analysis of medical records of patients admitted during the period from January to December 2011. Data on the incidence of constipati...

  8. The current status of grazing incidence optics

    International Nuclear Information System (INIS)

    Aschenbach, B.

    1983-01-01

    The developments in the area of grazing incidence optics with emphasis on telescopes for use in X-ray astronomy are reviewed. The performance of existing high-resolution telescopes is outlined and compared with those expected from future missions like ROSAT and AXAF. Starting from the basic principles of X-ray reflection and scattering, an attempt is made to highlight the current understanding of X-ray mirror physics using new theoretical ideas as well as experimental laboratory results. (author)

  9. Critical incidents connected to nurses’ leadership in Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Elaine Cantarella Lima

    Full Text Available ABSTRACT Objective: The goal of this study is to analyze nurses’ leadership in intensive care units at hospitals in the state of São Paulo, Brazil, in the face of positive and negative critical incidents. Method: Exploratory, descriptive study, conducted with 24 nurses by using the Critical Incident Technique as a methodological benchmark. Results: Results were grouped into 61 critical incidents distributed into categories. Researchers came to the conclusion that leadership-related situations interfere with IC nurses’ behaviors. Among these situations they found: difficulty in the communication process; conflicts in the daily exercise of nurses’ activities; people management; and the setting of high quality care targets. Final considerations: Researchers identified a mixed leadership model, leading them to the conclusion that nurses’ knowledge and practice of contemporary leadership theories/styles are crucial because they facilitate the communication process, focusing on behavioral aspects and beliefs, in addition to valuing flexibility. This positively impacts the organization’s results.

  10. The Incidence and Intensity of Formal Lifelong Learning

    DEFF Research Database (Denmark)

    Simonsen, Marianne; Skipper, Lars

    across genders. We consider both the incidence (take-up in a given year) and intensity (hours conditional on enrolment) of training. We find evidence of considerable lifelong learning with regards to enrolment in basic and vocational training regardless of gender, whereas post-secondary training...... hours in post-secondary training are strongly age dependent. Hours in basic training do decrease significantly with age but the effects are very small....

  11. Intensity-dependent nonlinear optical properties in a modulation-doped single quantum well

    International Nuclear Information System (INIS)

    Ungan, F.

    2011-01-01

    In the present work, the changes in the intersubband optical absorption coefficients and the refractive index in a modulation-doped quantum well have been investigated theoretically. Within the envelope function approach and the effective mass approximation, the electronic structure of the quantum well is calculated from the self-consistent numerical solution of the coupled Schroedinger-Poisson equations. The analytical expressions of optical properties are obtained by using the compact density-matrix approach. The numerical results GaAs/Al x Ga 1-x As are presented for typical modulation-doped quantum well system. The linear, third-order nonlinear and total absorption and refractive index changes depending on the doping concentration are investigated as a function of the incident optical intensity and structure parameters, such as quantum well width and stoichiometric ratio. The results show that the doping concentration, the structure parameters and the incident optical intensity have a great effect on the optical characteristics of these structures. - Highlights: → The doping concentration has a great effect on the optical characteristics of these structures. → The structure parameters have a great effect on the optical properties of these structures. → The total absorption coefficients reduced as the incident optical intensity increases. → The RICs reduced as the incident optical intensity increases.

  12. Incidence of constipation in an intensive care unit.

    Science.gov (United States)

    Guerra, Tatiana Lopes de Souza; Mendonça, Simone Sotero; Marshall, Norma Guimarães

    2013-01-01

    To evaluate the incidence of constipation in critical patients on enteral nutrition in a hospital intensive care unit and to correlate this incidence with the variables found for critical patients. The present investigation was a retrospective analytical study conducted in the intensive care unit of Hospital Regional da Asa Norte (DF) via the analysis of medical records of patients admitted during the period from January to December 2011. Data on the incidence of constipation and enteral nutritional support, gastrointestinal changes, stool frequency, ventilatory support, and outcomes were collected and analyzed. The initial sample consisted of 127 patients admitted to the unit during the period from January to December 2011. Eighty-four patients were excluded, and the final sample consisted of 43 patients. The incidence of constipation, defined as no bowel movement during the first 4 days of hospitalization, was 72% (n=31). The patients were divided into a control group and a constipated group. The group of constipated patients reached the caloric target, on average, at 6.5 days, and the control group reached the caloric target in 5.6 days (p=0.51). Constipation was not associated with the length of hospital stay, suspension of nutritional support, or outcome of hospitalization. There was an association between evacuation during hospitalization and a longer duration of hospitalization for a subgroup of patients who did not evacuate during the entire period (p=0.009). The incidence of constipation in the unit studied was 72%. Only the absence of evacuation during hospitalization was associated with longer hospital stays. Constipation was not associated with the length of hospital stay, suspension of nutritional support, or outcome of hospitalization.

  13. Active Full-Shell Grazing-Incidence Optics

    Science.gov (United States)

    Davis, Jacqueline M.; Elsner, Ronald F.; Ramsey, Brian D.; O'Dell, Stephen L.; Kolodziejczak, Jeffery; Weisskopf, Martin C.; Gubarev, Mikhail V.

    2016-01-01

    MSFC has a long history of developing full-shell grazing-incidence x-ray optics for both narrow (pointed) and wide field (surveying) applications. The concept presented in this paper shows the potential to use active optics to switch between narrow and wide-field geometries, while maintaining large effective area and high angular resolution. In addition, active optics has the potential to reduce errors due to mounting and manufacturing lightweight optics. The design presented corrects low spatial frequency error and has significantly fewer actuators than other concepts presented thus far in the field of active x-ray optics. Using a finite element model, influence functions are calculated using active components on a full-shell grazing-incidence optic. Next, the ability of the active optic to effect a change of optical prescription and to correct for errors due to manufacturing and mounting is modeled.

  14. Constipation in intensive care unit: incidence and risk factors.

    Science.gov (United States)

    Nassar, Antonio Paulo; da Silva, Fernanda Maria Queiroz; de Cleva, Roberto

    2009-12-01

    Although gastrointestinal motility disorders are common in critically ill patients, constipation and its implications have received very little attention. We aimed to determine the incidence of constipation to find risk factors and its implications in critically ill patients During a 6-month period, we enrolled all patients admitted to an intensive care unit from an universitary hospital who stayed 3 or more days. Patients submitted to bowel surgery were excluded. Constipation occurred in 69.9% of the patients. There was no difference between constipated and not constipated in terms of sex, age, Acute Physiology and Chronic Health Evaluation II, type of admission (surgical, clinical, or trauma), opiate use, antibiotic therapy, and mechanical ventilation. Early (constipation, a finding that persisted at multivariable analysis (P Constipation was not associated with greater intensive care unit or mortality, length of stay, or days free from mechanical ventilation. Constipation is very common among critically ill patients. Early enteral nutrition is associated with earlier return of bowel function.

  15. Optical Co-Incidence Gate | Srinivasulu | African Journal of Science ...

    African Journals Online (AJOL)

    The paper explains Optical co-incidence gate, realized using Unijunction transistors (UJT), Light emitting diodes (LED) and Photo-resistors (LDR), which works on 1.8Vdc instead of 3Vdc. The power dissipation of the designed gate is only 3 mW. This optical gate finds application in the field of Mechatronics, Instrumentation ...

  16. An Evaluation of Grazing-Incidence Optics for Neutron Imaging

    Science.gov (United States)

    Gubarev, M. V.

    2007-01-01

    The refractive index for most materials is slightly less than unity, which opens an opportunity to develop the grazing incidence neutron imaging optics. The ideal material for the optics would be natural nickel and its isotopes. Marshall Space Flight Center (MSFC) has active development program on the nickel replicated optics for use in x-ray astronomy. Brief status report on the program is presented. The results of the neutron focusing optic test carried by the MSFC team at National Institute of Standards and Technology (NIST) are also presented. Possible applications of the optics are briefly discussed.

  17. Critical incidents connected to nurses' leadership in Intensive Care Units.

    Science.gov (United States)

    Lima, Elaine Cantarella; Bernardes, Andrea; Baldo, Priscila Lapaz; Maziero, Vanessa Gomes; Camelo, Silvia Helena Henriques; Balsanelli, Alexandre Pazetto

    2017-01-01

    The goal of this study is to analyze nurses' leadership in intensive care units at hospitals in the state of São Paulo, Brazil, in the face of positive and negative critical incidents. Exploratory, descriptive study, conducted with 24 nurses by using the Critical Incident Technique as a methodological benchmark. Results were grouped into 61 critical incidents distributed into categories. Researchers came to the conclusion that leadership-related situations interfere with IC nurses' behaviors. Among these situations they found: difficulty in the communication process; conflicts in the daily exercise of nurses' activities; people management; and the setting of high quality care targets. Researchers identified a mixed leadership model, leading them to the conclusion that nurses' knowledge and practice of contemporary leadership theories/styles are crucial because they facilitate the communication process, focusing on behavioral aspects and beliefs, in addition to valuing flexibility. This positively impacts the organization's results. Analisar a liderança do enfermeiro em Centros de Terapia Intensiva de hospitais localizados no interior do estado de São Paulo, diante de incidentes críticos positivos e negativos. Estudo exploratório, descritivo, realizado com 24 enfermeiros, que utilizou a Técnica do Incidente Crítico como referencial metodológico. Os resultados foram agrupados em 61 incidentes críticos distribuídos em categorias. Identificou-se que situações relacionadas à liderança interferem no comportamento do enfermeiro de Terapia Intensiva, dentre elas: dificuldade no processo de comunicação, conflitos existentes no dia a dia do exercício profissional, gerenciamento de pessoas e estabelecimento de metas para o alcance da assistência qualificada. Encontrou-se um modelo misto de liderança, o que permite concluir que o conhecimento e a prática dos enfermeiros acerca de teorias/estilos contemporâneos de liderança tornam-se fundamentais, pois

  18. Active Micro structured Optical Arrays of Grazing Incidence Reflectors

    International Nuclear Information System (INIS)

    Willingale, R.; Feldman, Ch.; Michette, A.; Hart, D.; McFaul, Ch; Morrison, G.R.; Pfauntsch, S.; Powell, A.K.; Sahraei, Sh.; Shand, M.T.; Button, T.; Rodriguez-Sanmartin, D.; Zhang, D.; Dunare, C.; Parkes, W.; Stevenson, T.; Folkard, M.; Vojnovic, B.; Vojnovic, B.

    2011-01-01

    The UK Smart X-Ray Optics (SXO) programme is developing active/adaptive optics for terrestrial applications. One of the technologies proposed is micro structured optical arrays (MOAs), which focus X-rays using grazing incidence reflection through consecutive aligned arrays of microscopic channels. Although such arrays are similar in concept to poly capillary and microchannel plate optics, they can be bent and adjusted using piezoelectric actuators providing control over the focusing and inherent aberrations. Custom configurations can be designed, using ray tracing and finite element analysis, for applications from sub-keV to several-keV X-rays, and the channels of appropriate aspect ratios can be made using deep silicon etching. An exemplar application will be in the micro probing of biological cells and tissue samples using Ti Ka radiation (4.5?keV) in studies related to radiation-induced cancers. This paper discusses the optical design, modelling, and manufacture of such optics

  19. Aplanatic grazing incidence diffraction grating: a new optical element

    International Nuclear Information System (INIS)

    Hettrick, M.C.

    1986-01-01

    We present the theory of a grazing incidence reflection grating capable of imaging at submicron resolution. The optic is mechanically ruled on a spherical or cylindrical surface with varied groove spacings, delivering diffraction-limited response and a wide field of view at a selected wavelength. Geometrical aberrations are calculated on the basis of Fermat's principle, revealing significant improvements over a grazing incidence mirror. Aplanatic and quasi-aplanatic versions of the grating have applications in both imaging and scanning microscopes, microprobes, collimators, and telescopes. A 2-D crossed system of such gratings, similar to the grazing incidence mirror geometry of Kirkpatrick and Baez, could potentially provide spatial resolutions of --200 A

  20. Adjustable Grazing-Incidence X-Ray Optics

    Science.gov (United States)

    O'Dell, Stephen L.; Reid, Paul B.

    2015-01-01

    With its unique subarcsecond imaging performance, NASA's Chandra X-ray Observatory illustrates the importance of fine angular resolution for x-ray astronomy. Indeed, the future of x-ray astronomy relies upon x-ray telescopes with comparable angular resolution but larger aperture areas. Combined with the special requirements of nested grazing-incidence optics, mass, and envelope constraints of space-borne telescopes render such advances technologically and programmatically challenging. The goal of this technology research is to enable the cost-effective fabrication of large-area, lightweight grazing-incidence x-ray optics with subarcsecond resolution. Toward this end, the project is developing active x-ray optics using slumped-glass mirrors with thin-film piezoelectric arrays for correction of intrinsic or mount-induced distortions.

  1. Incidence and risk factors for thrombocytopenia in the intensive care ...

    African Journals Online (AJOL)

    the incidence, risk factors and transfusion requirements of thrombocytopenia in tertiary care ICUs in northern India. Objective. To study the incidence and ... [1] Thrombocytopenia has been found to predispose patients to increased ... any intracranial bleed or any bleed associated with a fall in haemoglobin by at least 2 g/dL.

  2. Intense laser effects on nonlinear optical absorption and optical rectification in single quantum wells under applied electric and magnetic field

    International Nuclear Information System (INIS)

    Duque, C.A.; Kasapoglu, E.; Sakiroglu, S.; Sari, H.; Soekmen, I.

    2011-01-01

    In this work the effects of intense laser on the electron-related nonlinear optical absorption and nonlinear optical rectification in GaAs-Ga 1-x Al x As quantum wells are studied under, applied electric and magnetic field. The electric field is applied along the growth direction of the quantum well whereas the magnetic field has been considered to be in-plane. The calculations were performed within the density matrix formalism with the use of the effective mass and parabolic band approximations. The intense laser effects are included through the Floquet method, by modifying the confining potential associated to the heterostructure. Results are presented for the nonlinear optical absorption, the nonlinear optical rectification and the resonant peak of these two optical processes. Several configurations of the dimensions of the quantum well, the applied electric and magnetic fields, and the incident intense laser radiation have been considered. The outcome of the calculation suggests that the nonlinear optical absorption and optical rectification are non-monotonic functions of the dimensions of the heterostructure and of the external perturbations considered in this work.

  3. Spiral intensity patterns in the internally pumped optical parametric oscillator

    DEFF Research Database (Denmark)

    Lodahl, Peter; Bache, Morten; Saffman, Mark

    2001-01-01

    We describe a nonlinear optical system that supports spiral pattern solutions in the field intensity. This new spatial structure is found to bifurcate above a secondary instability in the internally pumped optical parametric oscillator. The analytical predictions of threshold and spatial scale...

  4. Experimental Investigation of Integrated Optical Intensive Impulse Electric Field Sensors

    International Nuclear Information System (INIS)

    Bao, Sun; Fu-Shen, Chen

    2009-01-01

    We design and fabricate an integrated optical electric field sensor with segmented electrode for intensive impulse electric field measurement. The integrated optical sensor is based on a Mach–Zehnder interferometer with segmented electrodes. The output/input character of the sensing system is analysed and measured. The maximal detectable electric field range (−75 kV/m to 245 kV/m) is obtained by analysing the results. As a result, the integrated optics electric field sensing system is suitable for transient intensive electric field measurement investigation

  5. Incidence, progression and intensity of Bud Rot in Elaeis guineensis Jacq. in San Lorenzo, Ecuador

    Directory of Open Access Journals (Sweden)

    Fernando Rivas Figueroa

    2017-01-01

    Full Text Available BUD rot (BR is the most serious disease of oil palm in Latin America; in Equator has caused more than 150 million USD of losses. The aim of this work was to determine the incidence, progression and disease intensity of BR in E. guineensis. Incidence and disease progression was determined from data of oil palm enterprises: Palesema, PDA, Palpailón, Energy & Palma y Alespalma during 2006-2013. Disease intensity was determined at 2013. Incidence was 66.75 % and disease intensity was 46 %. Based on projections of accumulative incidence a polynomial equation was built that predicted 78.30 % of cumulative incidence for 2014, indicating exponential growth of BR from 2009 to 2013. Magnitude of damages based on incidence, disease progression and infection index indicated the occurrence of a lethal form of BR in San Lorenzo, province of Esmeraldas, Equator.

  6. Incidence of intravenous drug incompatibilities in intensive care units

    Czech Academy of Sciences Publication Activity Database

    Machotka, O.; Maňák, J.; Kuběna, Aleš Antonín; Vlček, J.

    2015-01-01

    Roč. 159, č. 4 (2015), s. 652-656 ISSN 1213-8118 Institutional support: RVO:67985556 Keywords : medical error * graph theory * graph coloring * drug administration * drug incompatibilities * applied combinatorics * decision theory * medical * medication safety * intensive care units Subject RIV: FN - Epidemiology, Contagious Diseases ; Clinical Immunology Impact factor: 0.924, year: 2015 http://library.utia.cas.cz/separaty/2014/E/kubena-0437509.pdf

  7. Exercise Intensity and Incidence of Metabolic Syndrome: The SUN Project.

    Science.gov (United States)

    Hidalgo-Santamaria, María; Fernandez-Montero, Alejandro; Martinez-Gonzalez, Miguel A; Moreno-Galarraga, Laura; Sanchez-Villegas, Almudena; Barrio-Lopez, María T; Bes-Rastrollo, Maira

    2017-04-01

    Emerging evidence suggests that vigorous physical activity may be associated with higher cardioprotective benefits than moderate physical activity. This study aimed to assess the long-term relationship between the intensity of leisure time physical activity (LTPA) and the risk of developing metabolic syndrome (MS) in a prospective cohort study. The Seguimiento Universidad de Navarra (SUN) Project comprises Spanish university graduates. Participants (n=10,145) initially free of MS were followed for a minimum of 6 years (2008-2014). Analysis was conducted in 2015. Physical activity was assessed though a validated questionnaire. The intensity of each physical activity was measured in METs. The intensity of LTPA was estimated by the ratio between total METs/week and total hours of LTPA/week, obtaining the mean METs/hour of LTPA. MS was defined according to the harmonizing definition. The association between the intensity of LTPA (METs/hour) and MS was assessed with logistic regression models adjusting for potential confounders. Among 10,145 participants initially free of any MS criteria, 412 new MS cases were observed. Vigorous LTPA was associated with a 37% relatively lower risk (AOR=0.63, 95% CI=0.44, 0.89) compared with light LTPA. For a given total energy expenditure, independent of the time spent on it, participants who performed vigorous LTPA exhibited a higher reduction in the risk of MS than those who performed light to moderate LTPA. Vigorous LTPA was significantly associated with lower risk of developing MS after a 6-year follow-up period. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Brief Report: Incidence of and Risk Factors for Autistic Disorder in Neonatal Intensive Care Unit Survivors.

    Science.gov (United States)

    Matsuishi, Toyojiro; Yamashita, Yushiro; Ohtani, Yasuyo; Ornitz, Edward; Kuriya, Norikazu; Murakami, Yoshihiko; Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Fumio

    1999-01-01

    Analysis of the incidence of autistic disorder (AD) among 5,271 children in a neonatal intensive care unit in Japan found that 18 children were later diagnosed with AD, an incidence more than twice as high as previously reported. Children with AD had a significantly higher history of the meconium aspiration syndrome than the controls. (Author/DB)

  9. Generation of equal-intensity coherent optical beams by binary geometrical phase on metasurface

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zheng-Han; Jiang, Shang-Chi; Xiong, Xiang; Peng, Ru-Wen, E-mail: rwpeng@nju.edu.cn, E-mail: muwang@nju.edu.cn; Wang, Mu, E-mail: rwpeng@nju.edu.cn, E-mail: muwang@nju.edu.cn [National Laboratory of Solid State Microstructures and School of Physics, and Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China)

    2016-06-27

    We report here the design and realization of a broadband, equal-intensity optical beam splitter with a dispersion-free binary geometric phase on a metasurface with unit cell consisting of two mirror-symmetric elements. We demonstrate experimentally that two identical beams can be efficiently generated with incidence of any polarization. The efficiency of the device reaches 80% at 1120 nm and keeps larger than 70% in the range of 1000–1400 nm. We suggest that this approach for generating identical, coherent beams have wide applications in diffraction optics and in entangled photon light source for quantum communication.

  10. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas

    2017-09-18

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  11. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2017-01-01

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  12. Grazing incidence optics; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

    Science.gov (United States)

    Osantowski, John F. (Editor); Van Speybroeck, Leon (Editor)

    1986-01-01

    Papers are presented on the diffraction-limited performance of grazing incidence optical systems; transverse ray aberrations of Wolter type 1 telescopes; hybrid X-ray telescope systems; surface characterization of grazing incidence optics in the extreme UV and X-ray regions; and the surface roughness properties of synchrotron radiation optics. Topics discussed include the simulation of free-abrasive grinding of grazing incidence mirrors with vertical-honing and flexible blades; mirrors for the Extreme Ultraviolet Explorer; the design and development of conical X-ray imaging mirrors; thermal loading considerations for synchrotron radiation mirrors; and grazing incidence optics for synchrotron radiation insertion-device beams. Consideration is given to the interpretation of glancing incidence scattering measurements; damage processes in short wavelength coated FEL optics; the replication of grain incidence optics; and the assembly and alignment of the Technology Mirror Assembly.

  13. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ˜95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ˜6.0%.

  14. Optical properties of a multibarrier structure under intense laser fields

    Science.gov (United States)

    Ospina, D. A.; Akimov, V.; Mora-Ramos, M. E.; Morales, A. L.; Tulupenko, V.; Duque, C. A.

    2015-11-01

    Using the diagonalization method and within the effective mass and parabolic band approximations, the energy spectrum and the wave functions are investigated in biased multibarrier structure taking into account the effects of nonresonant intense laser fields. We calculated the optical properties from the susceptibility using a nonperturbative formalism recently reported. We study the changes in the intersubband optical absorption coefficients and refraction index for several values of the dressing laser parameter and for some specific values of the electric field applied along the growth direction of the heterostructure. It is concluded from our study that the peaks in the optical absorption spectrum have redshifts or blueshifts as a function of the laser parameter and the electric field. These parameters could be suitable tools for tuning the electronic and optical properties of the multibarrier structure.

  15. Climate variability and increase in intensity and magnitude of dengue incidence in Singapore

    OpenAIRE

    Hii, Yien Ling; Rocklöv, Joacim; Ng, Nawi; Tang, Choon Siang; Pang, Fung Yin; Sauerborn, Rainer

    2009-01-01

    Introduction: Dengue is currently a major public health burden in Asia Pacific Region. This study aims to establish an association between dengue incidence, mean temperature and precipitation and further discuss how weather predictors influence the increase in intensity and magnitude of dengue in Singapore during the period 2000-2007. Materials and methods: Weekly dengue incidence data, daily mean temperature and precipitation and the midyear population data in Singapore during 2000-2007 were...

  16. Optical diagnostics of mercury jet for an intense proton target.

    Science.gov (United States)

    Park, H; Tsang, T; Kirk, H G; Ladeinde, F; Graves, V B; Spampinato, P T; Carroll, A J; Titus, P H; McDonald, K T

    2008-04-01

    An optical diagnostic system is designed and constructed for imaging a free mercury jet interacting with a high intensity proton beam in a pulsed high-field solenoid magnet. The optical imaging system employs a backilluminated, laser shadow photography technique. Object illumination and image capture are transmitted through radiation-hard multimode optical fibers and flexible coherent imaging fibers. A retroreflected illumination design allows the entire passive imaging system to fit inside the bore of the solenoid magnet. A sequence of synchronized short laser light pulses are used to freeze the transient events, and the images are recorded by several high speed charge coupled devices. Quantitative and qualitative data analysis using image processing based on probability approach is described. The characteristics of free mercury jet as a high power target for beam-jet interaction at various levels of the magnetic induction field is reported in this paper.

  17. Intensity modulated radiotherapy for sinonasal malignancies with a focus on optic pathway preservation

    Directory of Open Access Journals (Sweden)

    Chi Alexander

    2013-01-01

    Full Text Available Abstract Purpose To assess if intensity-modulated radiotherapy (IMRT can possibly lead to improved local control and lower incidence of vision impairment/blindness in comparison to non-IMRT techniques when treating sinonasal malignancies; what is the most optimal dose constraints for the optic pathway; and the impact of different IMRT strategies on optic pathway sparing in this setting. Methods and materials A literature search in the PubMed databases was conducted in July, 2012. Results Clinical studies on IMRT and 2D/3D (2 dimensional/3 dimensional RT for sinonasal malignancies suggest improved local control and lower incidence of severe vision impairment with IMRT in comparison to non-IMRT techniques. As observed in the non-IMRT studies, blindness due to disease progression may occur despite a lack of severe toxicity possibly due to the difficulty of controlling locally very advanced disease with a dose ≤ 70 Gy. Concurrent chemotherapy’s influence on the the risk of severe optic toxicity after radiotherapy is unclear. A maximum dose of ≤ 54 Gy with conventional fractionation to the optic pathway may decrease the risk of blindness. Increased magnitude of intensity modulation through increasing the number of segments, beams, and using a combination of coplanar and non-coplanar arrangements may help increase dose conformality and optic pathway sparing when IMRT is used. Conclusion IMRT optimized with appropriate strategies may be the treatment of choice for the most optimal local control and optic pathway sparing when treating sinonasal malignancy.

  18. Analysis of contributing factors associated to related patients safety incidents in Intensive Care Medicine.

    Science.gov (United States)

    Martín Delgado, M C; Merino de Cos, P; Sirgo Rodríguez, G; Álvarez Rodríguez, J; Gutiérrez Cía, I; Obón Azuara, B; Alonso Ovies, Á

    2015-01-01

    To explore contributing factors (CF) associated to related critical patients safety incidents. SYREC study pos hoc analysis. A total of 79 Intensive Care Departments were involved. The study sample consisted of 1.017 patients; 591 were affected by one or more incidents. The CF were categorized according to a proposed model by the National Patient Safety Agency from United Kingdom that was modified. Type, class and severity of the incidents was analyzed. A total 2,965 CF were reported (1,729 were associated to near miss and 1,236 to adverse events). The CF group more frequently reported were related patients factors. Individual factors were reported more frequently in near miss and task related CF in adverse events. CF were reported in all classes of incidents. The majority of CF were reported in the incidents classified such as less serious, even thought CF patients factors were associated to serious incidents. Individual factors were considered like avoidable and patients factors as unavoidable. The CF group more frequently reported were patient factors and was associated to more severe and unavoidable incidents. By contrast, individual factors were associated to less severe and avoidable incidents. In general, CF most frequently reported were associated to near miss. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  19. Incidence and risk factors associated with the development of pressure ulcers in an intensive care unit.

    Science.gov (United States)

    González-Méndez, María Isabel; Lima-Serrano, Marta; Martín-Castaño, Catalina; Alonso-Araujo, Inmaculada; Lima-Rodríguez, Joaquín Salvador

    2018-03-01

    To determinate the incidence, incidence rate and risk factors of pressure ulcers in critical care patients. Pressure ulcers represent one of the most frequent health problems in clinical practice. Specifically, critical patients who are hospitalised in intensive care units have a higher risk of developing a pressure ulcer, with an incidence that fluctuates between 3.3-39.3% according to previous studies. Prospective cohort study. Three hundred and thirty-five adult patients (over 18 years old) who were hospitalised in intensive care units for at least 24 hr were monitored for a maximum of 32 days. They were excluded if they had a pressure ulcers at admission. The survival rate for pressure ulcers, from stages I-IV, was calculated using the Kaplan-Meier method. A multivariate Cox regression model was adjusted to identify the main risk factors for pressure ulcers: demographic, clinical, prognostic and therapeutic variables. The incidence of pressure ulcers in critical patients was 8.1%, and the incidence rate was 11.72 pressure ulcers for 1,000 days of intensive care units stay; 40.6% of pressure ulcers were of stage I and 59.4% of stage II, mainly in the sacrum. According to the Cox model, the main risk factors for pressure ulcers were in-hospital complications, prognostic scoring system (SAPS III) and length of immobilisation. The incidence of pressure ulcers is lower than that shown in recent studies. Complications on the unit and the prognosis score were risk factors associated with pressure ulcers but, surprisingly, length of immobilisation was a protective factor. Survival analysis of pressure ulcer allows for identification of risk factors associated with this health problem in the intensive care units. Identifying these factors can help nurses establish interventions to prevent pressure ulcers in this healthcare scenario, given that pressure ulcers prevention is an indicator of nursing quality. © 2017 John Wiley & Sons Ltd.

  20. Light intensity dependent optical rotation in azobenzene polymers

    Science.gov (United States)

    Ivanov, M.; Ilieva, D.; Petrova, T.; Dragostinova, V.; Todorov, T.; Nikolova, L.

    2006-05-01

    We investigate the self-induced rotation of the azimuth of light polarization ellipse in azobenzene polymers. It is initiated by the photoreorientation and ordering of the azobenzenes on illumination with elliptically polarized light resulting in the appearance of an optical axis whose direction is gradually rotated along the depth of the film. A macroscopic chiral structure is created with a pitch depending on light ellipticity and the photobirefringence ▵n in the successive layers of the film. In this work we make use of the fact that at elevated temperatures ▵n is very sensitive to light intensity. In our acrylic amorphous azobenzene polymer at temperatures 50-65°C the saturated values of ▵n are much higher for low intensity of the exciting light than for higher intensity. In this temperature range the polarization azimuth of monochromatic blue light with different intensity is rotated to a different angle after passing through the polymer film. This effect can be used for passive elements rotating the polarization azimuth depending on light intensity and for the formation of light beams with a space-variant polarization state.

  1. [Incidence of multi-resistant bacteria in Intensive Care Units of Chilean hospitals].

    Science.gov (United States)

    Acuña, M Paz; Cifuentes, Marcela; Silva, Francisco; Rojas, Álvaro; Cerda, Jaime; Labarca, Jaime

    2017-12-01

    Incidence of multi-resistant bacteria is an indicator that permits better estimation of the magnitude of bacterial resistance in hospitals. To evaluate the incidence of relevant multi-drug resistant bacteria in intensive care units (ICUs) of Chile. Participating hospitals submitted information about the number of isolates from infected or colonized patients with 7 epidemiologically relevant multi-resistant bacteria in adult and pediatric ICUs between January 1, 2014 and October 31, 2015 and the number of bed days occupied in these units in the same period was requested. With these data incidence was calculated per 1,000 patient days for each unit. Information from 20 adults and 9 pediatric ICUs was reviewed. In adult ICUs the bacteria with the highest incidence were K. pneumoniae ESBL [4.72 × 1,000 patient day (1.21-13.89)] and oxacillin -resistant S. aureus [3.85 (0.71-12.66)]. In the pediatric units the incidence was lower, highlighting K. pneumoniae ESBL [2.71 (0-7.11)] and carbapenem -resistant P. aeruginosa [1.61 (0.31-9.25)]. Important differences between hospitals in the incidence of these bacteria were observed. Incidence of multi-resistant bacteria in adult ICU was significantly higher than in pediatric ICU for most of the studied bacterias.

  2. Acute respiratory distress syndrome: an audit of incidence and outcome in Scottish intensive care units.

    Science.gov (United States)

    Hughes, M; MacKirdy, F N; Ross, J; Norrie, J; Grant, I S

    2003-09-01

    This prospective audit of incidence and outcome of the acute respiratory distress syndrome was conducted as part of the national audit of intensive care practice in Scotland. All patients with acute respiratory distress syndrome in 23 adult intensive care units were identified using the diagnostic criteria defined by the American-European Consensus Conference. Daily data collection was continued until death or intensive care unit discharge. Three hundred and sixty-nine patients were diagnosed with acute respiratory distress syndrome over the 8-month study period. The frequency of acute respiratory distress syndrome in the intensive care unit population was 8.1%; the incidence in the Scottish population was estimated at 16.0 cases.100,000(-1).year(-1). Intensive care unit mortality for acute respiratory distress syndrome was 53.1%, with a hospital mortality of 60.9%. In our national unselected population of critically ill patients, the overall outcome is comparable with published series (Acute Physiology and Chronic Health Evaluation II standardised mortality ratio = 0.99). However, mortality from acute respiratory distress syndrome in Scotland is substantially higher than in recent other series suggesting an improvement in outcome in this condition.

  3. Optical intensity scintillation in the simulated atmospherical environment

    Science.gov (United States)

    Hajek, Lukas; Latal, Jan; Vanderka, Ales; Vitasek, Jan; Bojko, Marian; Bednarek, Lukas; Vasinek, Vladimir

    2016-09-01

    There are several parameters of the atmospheric environment which have an effect on the optical wireless connection. Effects like fog, snow or rain are ones of the effects which appears tendentiously and which are bound by season, geographic location, etc. One of the effects that appear with various intensity for the whole time is airflow. The airflow changes the local refractive index of the air and areas with lower or higher refractive index form. The light going through these areas refracts and due to the optical intensity scintillates on the detector of the receiver. The airflow forms on the basis of two effects in the atmosphere. The first is wind cut and flowing over barriers. The other is thermal flow when warm air rises to the higher layers of the atmosphere. The heart of this article is creation such an environment that will form airflow and the refractive index will scintillate. For the experiment, we used special laboratory box with high-speed ventilators and heating units to simulate atmospheric turbulence. We monitor the impact of ventilator arrangement and air temperature on the scintillation of the gas laser with wavelength 633 nm/15 mW. In the experiment, there is watched the difference in behavior between real measurement and flow simulation with the same peripheral conditions of the airflow in the area of 500 x 500 cm.

  4. Climate variability and increase in intensity and magnitude of dengue incidence in Singapore.

    Science.gov (United States)

    Hii, Yien Ling; Rocklöv, Joacim; Ng, Nawi; Tang, Choon Siang; Pang, Fung Yin; Sauerborn, Rainer

    2009-11-11

    Dengue is currently a major public health burden in Asia Pacific Region. This study aims to establish an association between dengue incidence, mean temperature and precipitation, and further discuss how weather predictors influence the increase in intensity and magnitude of dengue in Singapore during the period 2000-2007. Weekly dengue incidence data, daily mean temperature and precipitation and the midyear population data in Singapore during 2000-2007 were retrieved and analysed. We employed a time series Poisson regression model including time factors such as time trends, lagged terms of weather predictors, considered autocorrelation, and accounted for changes in population size by offsetting. The weekly mean temperature and cumulative precipitation were statistically significant related to the increases of dengue incidence in Singapore. Our findings showed that dengue incidence increased linearly at time lag of 5-16 and 5-20 weeks succeeding elevated temperature and precipitation, respectively. However, negative association occurred at lag week 17-20 with low weekly mean temperature as well as lag week 1-4 and 17-20 with low cumulative precipitation. As Singapore experienced higher weekly mean temperature and cumulative precipitation in the years 2004-2007, our results signified hazardous impacts of climate factors on the increase in intensity and magnitude of dengue cases. The ongoing global climate change might potentially increase the burden of dengue fever infection in near future.

  5. The Development of a Differential Deposition Technique for Figure Correction in Grazing Incidence Optics

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a physical-vapor-deposition coating technique to correct residual figure errors in grazing-incidence optics. The process involves...

  6. Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

    2006-11-14

    This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silica high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 μm) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.

  7. Pressure ulcer in intensive care unit: analysis of incidence and injuries installed

    Directory of Open Access Journals (Sweden)

    Maria do Livramento Neves Silva

    2013-11-01

    Full Text Available A longitudinal quantitative study carried out in the Intensive Care Unit of a public hospital in João Pessoa-PB, Brazil, from July to October 2012, which aimed to analyze the incidence of pressure ulcers and describe their characteristics. We monitored 36 patients who met the inclusion criteria. Data collection happened through physical examination and medical records. We verified that 22.2% of patients developed the injury, affecting equally men and women (50.0%, with predominance of Caucasians (62.5% and aged under 50 years (30.8%, which developed the injury in less than ten days (87.5%, in the sacral region (27.3% and classified in category II (63.6%. Despite investments in devices for prevention and treatment of pressure ulcers, these are still present in practice and with significant incidence. Therefore, we suggest investing in professional training, as well as develop and implement protocols for preventing this injury.

  8. Simulation calculation for the energy deposition profile and the transmission fraction of intense pulsed electron beam at various incident angles

    International Nuclear Information System (INIS)

    Yang Hailiang; Qiu Aici; Zhang Jiasheng; Huang Jianjun; Sun Jianfeng

    2002-01-01

    The incident angles have a heavy effect on the intense pulsed electron beam energy deposition profile, energy deposition fraction and beam current transmission fraction in material. The author presents electron beam energy deposition profile and energy deposition fraction versus electron energy (0.5-2.0 MeV), at various incident angles for three aluminum targets of various thickness via theoretical calculation. The intense pulsed electron beam current transmission fractions versus electron energy (0.4-1.4 MeV) at various incident angles for three thickness of carbon targets were also theoretically calculated. The calculation results indicate that the deposition energy in unit mass of material surface layer increase with the rise of electron beam incident angle, and electron beam with low incident angle (closer to normal incident angle) penetrates deeper into the target material. The electron beams deposit more energy in unit mass of material surface layer at 60 degree-70 degree incident angle

  9. Incidence and factors related to delirium in an intensive care unit.

    Science.gov (United States)

    Mori, Satomi; Takeda, Juliana Rumy Tsuchihashi; Carrara, Fernanda Souza Angotti; Cohrs, Cibelli Rizzo; Zanei, Suely Sueko Viski; Whitaker, Iveth Yamaguchi

    2016-01-01

    To identify the incidence of delirium, compare the demographic and clinical characteristics of patients with and without delirium, and verify factors related to delirium in critical care patients. Prospective cohort with a sample made up of patients hospitalized in the Intensive Care Unit (ICU) of a university hospital. Demographic, clinical variables and evaluation with the Confusion Assessment Method for Intensive Care Unit to identify delirium were processed to the univariate analysis and logistic regression to identify factors related to the occurrence of delirium. Of the total 149 patients in the sample, 69 (46.3%) presented delirium during ICU stay, whose mean age, severity of illness and length of ICU stay were statistically higher. The factors related to delirium were: age, midazolam, morphine and propofol. Results showed high incidence of ICU delirium associated with older age, use of sedatives and analgesics, emphasizing the need for relevant nursing care to prevent and identify early, patients presenting these characteristics. Identificar a incidência de delirium, comparar as características demográficas e clínicas dos pacientes com e sem delirium e verificar os fatores relacionados ao delirium em pacientes internados em Unidade de Terapia Intensiva (UTI). Coorte prospectiva, cuja amostra foi constituída de pacientes internados em UTI de um hospital universitário. Variáveis demográficas, clínicas e da avaliação com o Confusion Assessment Method for Intensive Care Unit para identificação de delirium foram processadas para análise univariada, e regressão logística para identificar fatores relacionados à ocorrência do delirium. Do total de 149 pacientes da amostra, 69 (46,3%) apresentaram delirium durante a internação na UTI, observando-se que a média da idade, o índice de gravidade e o tempo de permanência nas UTI foram estatisticamente maiores. Os fatores relacionados ao delirium foram: idade, midazolam, morfina e propofol. Os

  10. The Incidence And Risk Factors Nosocomial Pneumonia In A Neuromedical Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Devragudi TS

    2001-01-01

    Full Text Available This retrospective study examined the incidence and factors influencing the occurrence of nonsocomial pneumonia (NP in a neuromedical intensive care unit (NICU. Of the 57 patients admitted to the NICU over one year, 26% developed nosocomial pneumonia. It was observed that the infected patients were significantly older than the noninfected (43+15 vs 22+18 years; p<0.001, had a longer NICU stay (33+31 vs 18+18 days: p=0.05 and needed longer duration of mechanical ventilation (20+25 vs 9 + 12 days: P<0.05. Patients with neuromuscular diseases had a trend towards higher incidence of NP than those with encephalopathy and therapeutic interventions such as plasmapheresis, blood transfusion and inotropic therapy did not influence the incidence of nosocomial pneumonia. The NICU mortality was not significantly influenced by nosocomial pneumonia. Pseudomonas aerugenosa was the predominant organism responsible for pneumonia. Nine percent of the tracheobronchial isolates were resistant to the routinely-tested antibiotics. In conclusion, nosocornial pneumonia is a common complication in a NICU and while it increases the duration of NICU stay, mortality appears to be uninfluenced.

  11. X-ray microscopy using grazing-incidence reflections optics

    International Nuclear Information System (INIS)

    Price, R.H.

    1983-01-01

    The role of Kirkpatrick-Baez microscopes as the workhorse of the x-ray imaging devices is discussed. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics

  12. X-ray microscopy using grazing-incidence reflection optics

    International Nuclear Information System (INIS)

    Price, R.H.

    1981-01-01

    The Kirkpatrick-Baez microscopes are described along with their role as the workhorse of the x-ray imaging devices. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics

  13. Intensities of incident and transmitted ultraviolet-a rays through gafchromic films

    Directory of Open Access Journals (Sweden)

    Toshizo Katsuda

    2017-01-01

    Full Text Available Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission intensity. Gafchromic EBT3 films were suitable to be used in this study because non-UV protection layers are present on both sides of the film. The film is placed between UV-A ray light-emitting diodes and a probe of a UV meter. Gafchromic EBT3 films were irradiated by UV-A rays for up to 60 min. Data for analysis were obtained in the subsequent 60 min. Images from before and after UV-A irradiation were subtracted. When using 375 nm UV-A, the mean ± standard deviation (SD of the pixel values in the subtracted image was remarkably high (11,194.15 ± 586.63. However, the UV-A transmissivity remained constant throughout the 60 min irradiation period. The mean ± SD UV-A transmission intensity was 184.48 ± 0.50 μm/cm2. Our findings demonstrate that color density changes in Gafchromic EBT3 films do not affect their UV-A transmission. Therefore, Gafchromic films were irradiated by UV-A rays as a preexposure.

  14. Aplanatic telescopes based on Schwarzschild optical configuration: from grazing incidence Wolter-like x-ray optics to Cherenkov two-mirror normal incidence telescopes

    Science.gov (United States)

    Sironi, Giorgia

    2017-09-01

    At the beginning of XX century Karl Schwarzschild defined a method to design large-field aplanatic telescopes based on the use of two aspheric mirrors. The approach was then refined by Couder (1926) who, in order to correct for the astigmatic aberration, introduced a curvature of the focal plane. By the way, the realization of normal-incidence telescopes implementing the Schwarzschild aplanatic configuration has been historically limited by the lack of technological solutions to manufacture and test aspheric mirrors. On the other hand, the Schwarzschild solution was recovered for the realization of coma-free X-ray grazing incidence optics. Wolter-like grazing incidence systems are indeed free of spherical aberration, but still suffer from coma and higher order aberrations degrading the imaging capability for off-axis sources. The application of the Schwarzschild's solution to X-ray optics allowed Wolter to define an optical system that exactly obeys the Abbe sine condition, eliminating coma completely. Therefore these systems are named Wolter-Schwarzschild telescopes and have been used to implement wide-field X-ray telescopes like the ROSAT WFC and the SOHO X-ray telescope. Starting from this approach, a new class of X-ray optical system was proposed by Burrows, Burg and Giacconi assuming polynomials numerically optimized to get a flat field of view response and applied by Conconi to the wide field x-ray telescope (WFXT) design. The Schwarzschild-Couder solution has been recently re-discovered for the application to normal-incidence Cherenkov telescopes, thanks to the suggestion by Vassiliev and collaborators. The Italian Institute for Astrophysics (INAF) realized the first Cherenkov telescope based on the polynomial variation of the Schwarzschild configuration (the so-called ASTRI telescope). Its optical qualification was successfully completed in 2016, demonstrating the suitability of the Schwarzschild-like configuration for the Cherenkov astronomy requirements

  15. Experiment and application of soft x-ray grazing incidence optical scattering phenomena

    Science.gov (United States)

    Chen, Shuyan; Li, Cheng; Zhang, Yang; Su, Liping; Geng, Tao; Li, Kun

    2017-08-01

    For short wavelength imaging systems,surface scattering effects is one of important factors degrading imaging performance. Study of non-intuitive surface scatter effects resulting from practical optical fabrication tolerances is a necessary work for optical performance evaluation of high resolution short wavelength imaging systems. In this paper, Soft X-ray optical scattering distribution is measured by a soft X-ray reflectometer installed by my lab, for different sample mirrors、wavelength and grazing angle. Then aim at space solar telescope, combining these scattered light distributions, and surface scattering numerical model of grazing incidence imaging system, PSF and encircled energy of optical system of space solar telescope are computed. We can conclude that surface scattering severely degrade imaging performance of grazing incidence systems through analysis and computation.

  16. Differential Deposition for Surface Figure Corrections in Grazing Incidence X-Ray Optics

    Science.gov (United States)

    Ramsey, Brian D.; Kilaru, Kiranmayee; Atkins, Carolyn; Gubarev, Mikhail V.; Broadway, David M.

    2015-01-01

    Differential deposition corrects the low- and mid- spatial-frequency deviations in the axial figure of Wolter-type grazing incidence X-ray optics. Figure deviations is one of the major contributors to the achievable angular resolution. Minimizing figure errors can significantly improve the imaging quality of X-ray optics. Material of varying thickness is selectively deposited, using DC magnetron sputtering, along the length of optic to minimize figure deviations. Custom vacuum chambers are built that can incorporate full-shell and segmented Xray optics. Metrology data of preliminary corrections on a single meridian of full-shell x-ray optics show an improvement of mid-spatial frequencies from 6.7 to 1.8 arc secs HPD. Efforts are in progress to correct a full-shell and segmented optics and to verify angular-resolution improvement with X-ray testing.

  17. Incidence and preventability of adverse events requiring intensive care admission: a systematic review.

    Science.gov (United States)

    Vlayen, Annemie; Verelst, Sandra; Bekkering, Geertruida E; Schrooten, Ward; Hellings, Johan; Claes, Neree

    2012-04-01

    Adverse events are unintended patient injuries or complications that arise from health care management resulting in death, disability or prolonged hospital stay. Adverse events that require critical care are a considerable financial burden to the health care system, but also their global impact on patients and society is probably underestimated. The objectives of this systematic review were to synthesize the best available evidence regarding the estimates of the incidence and preventability of adverse events that necessitate intensive care admission, to determine the type and consequences [mortality, length of intensive care unit (ICU) stay and costs] of these adverse events. MEDLINE (from 1966 to present), EMBASE (from 1974 to present) and CENTRAL (version 1-2010) were searched for studies reporting on unplanned admissions on ICUs. Several other sources were searched for additional studies. Only quantitative studies that used chart review for the detection of adverse events requiring intensive care admission were considered for eligibility. For the purposes of this systematic review, ICUs were defined as specialized hospital facilities which provide continuous monitoring and intensive care for acutely ill patients. Studies that were published in the English, Dutch, German, French or Spanish language were eligible for inclusion. Two reviewers independently extracted data and assessed the methodological quality of the included studies. A total of 27 studies were reviewed. Meta-analysis of the data was not appropriate because of methodological and statistical heterogeneity between studies; therefore, results are presented in a descriptive way. The percentage of surgical and medical adverse events that required ICU admission ranged from 1.1% to 37.2%. ICU readmissions varied from 0% to 18.3%. Preventability of the adverse events varied from 17% to 76.5%. Preventable adverse events are further synthesized by type of event. Consequences of the adverse events included a

  18. Far-Infrared Magneto-Optical Studies in Germanium and Indium-Antimonide at High Intensities

    Science.gov (United States)

    Leung, Michael

    Observations of nonlinear magneto-optical phenomena occurring in p-type Germanium and n-type Indium Antimonide are reported. These include multi-photon ionization of impurity states, and a new observation, the magneto-photon ionization of impurity states, and a new observation, the magneto-photon drag effect. A novel source of far-infrared radiation has been used. This source uses a pulsed CO(,2) LASER to optically pump a super-radiant cell, generating light with intensities up to 100 KW/cm('2) and wavelengths from 66 (mu)m to 496 (mu)m in a pulse of 150 nanoseconds duration. The Germanium samples were doped with Gallium, which is a shallow acceptor with an ionization potential of 11 meV. At liquid Helium temperature virtually all charge carriers are bound to acceptor sites. However, the high intensity radiation unexpectedly ionizes the acceptors. This is demonstrated through measurements of photoconductivity, transmission and the photo-Hall Effect. This observation is unexpected because the photon energy is one-fourth the ionization potential. Rate equations describing sequential multiphoton excitations are in agreement with the experimental results. The intermediate states are postulated to be acceptor exciton band states. Studies of the photoexcited mobility at 496 (mu)m suggest that at non-saturating levels of photoexcitation, the primary scattering mechanism of hot holes in Germanium is by neutral impurities. A new magneto-optical effect, the magneto-photon drag effect, has been studied in both Germanium and Indium Antimonide. This is simply the absorption of momentum by free carriers, from an incident photon field. It has been found that the mechanism for this effect is different in the two materials. In Germanium, the effect occurs when carriers make optical transitions from the heavy hole band to the light hole band. Thus, the magneto-optical behavior depends heavily upon the band structure. On the other hand, a modified Drude model (independent electron

  19. Intensity-based fibre-optic sensing system using contrast modulation of subcarrier interference pattern

    Science.gov (United States)

    Adamovsky, G.; Sherer, T. N.; Maitland, D. J.

    1989-01-01

    A novel technique to compensate for unwanted intensity losses in a fiber-optic sensing system is described. The technique involves a continuous sinusoidal modulation of the light source intensity at radio frequencies and an intensity sensor placed in an unbalanced interferometer. The system shows high sensitivity and stability.

  20. Dispersion free full range spectral intensity optical coherence tomography

    DEFF Research Database (Denmark)

    Jensen, Mikkel; Israelsen, Niels Møller; Maria, Michael

    2017-01-01

    Optical coherence tomography (OCT) is a non-invasive imaging technique with many applications and widespread use in ophthalmology [1]. The axial resolution in OCT is inversely proportional to the bandwidth of the optical source used, but the improved axial resolution comes at the price of more...

  1. Incidence, characteristics, and survival following cardiopulmonary resuscitation in the quaternary neonatal intensive care unit.

    Science.gov (United States)

    Foglia, Elizabeth E; Langeveld, Robert; Heimall, Lauren; Deveney, Alyson; Ades, Anne; Jensen, Erik A; Nadkarni, Vinay M

    2017-01-01

    The contemporary characteristics and outcomes of cardiopulmonary resuscitation (CPR) in the neonatal intensive care unit (NICU) are poorly described. The objectives of this study were to determine the incidence, interventions, and outcomes of CPR in a quaternary referral NICU. Retrospective observational study of infants who received chest compressions for resuscitation in the Children's Hospital of Philadelphia NICU between April 1, 2011 and June 30, 2015. Patient, event, and survival characteristics were abstracted from the medical record and the hospital-wide resuscitation database. The primary outcome was survival to hospital discharge. Univariable and multivariable analyses were performed to identify patient and event factors associated with survival to discharge. There were 1.2 CPR events per 1000 patient days. CPR was performed in 113 of 5046 (2.2%) infants admitted to the NICU during the study period. The median duration of chest compressions was 2min (interquartile range 1, 6min). Adrenaline was administered in 34 (30%) CPR events. Of 113 infants with at least one CPR event, 69 (61%) survived to hospital discharge. Factors independently associated with decreased survival to hospital discharge were inotrope treatment prior to CPR (adjusted Odds Ratio [aOR] 0.14, 95% Confidence Interval [CI] 0.04, 0.54), and adrenaline administration during CPR (aOR 0.14, 95% CI 0.04, 0.50). Although it was not uncommon, the incidence of CPR was low (CPR and adrenaline administration during CPR were less likely to survive to hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Unplanned extubations in an intensive care unit: Findings from a critical incident technique.

    Science.gov (United States)

    Danielis, Matteo; Chiaruttini, Simona; Palese, Alvisa

    2018-05-15

    Patients on mechanical ventilation are at risk of experiencing a potentially life-threatening unplanned extubation in the intensive care unit, which can lead to arrhythmias, bronchial aspiration, difficulty in reintubation or even sudden cardiac arrest. Although incidence and outcomes of the phenomenon have been documented in several quantitative studies, no studies have investigated the antecedents as experienced by critical care nurses. To gain a greater understanding of the antecedents of unplanned extubations. A qualitative study design involving the critical-incident technique. A total of 10 registered nurses who reported one or more episodes of unplanned extubations were involved in an in-depth interview. According to the nurses' experience, episodes of unplanned extubations are determined by predisposing, precipitating and mediating factors. The predisposing factors have been recognised in the (a) weaning programme (expected/unexpected decreased sedation) and in the (b) patient factors (increased needs due to discomfort, restlessness and desire to communicate). The precipitating factors have been divided into (a) organisational (failures in multi-professional communication), (b) environmental (excessive environmental chaos and barriers preventing direct surveillance) and (c) nursing care factors (ensuring privacy by creating barriers, avoiding disturbing other patients and poor nurse-to-patient ratio). Among the mediating factors, which are affected by the precipitating factors, decreased surveillance and mechanical restraints' use have been identified. Identifying risk factors of unplanned extubation, specifically those that are modifiable, such as increasing interprofessional communication, reducing excessive environment chaos, implementing strategies aimed at overcoming barriers threatening direct surveillance and ensuring appropriate nurse-to-patient ratio, can prevent the occurrence of these events. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Effect of Gastric Acid Suppressant Prophylaxis on Incidence of Gastrointestinal Bleeding in Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Tahoora Abdollahi

    2016-11-01

    Full Text Available Background: Critically ill children admitted to pediatric intensive care unit (PICU are at increased risk of gastrointestinal bleeding due to stress related mucosal injury. Reducing gastric acid by acid suppressant medication is the accepted prophylaxis treatment, but there is not any definitive guideline for using prophylaxis in PICU patients. The present study aimed to assess the effect of Proton Pump Inhibitor (PPI and H2 Blocker (H2B prophylaxis on gastrointestinal bleeding in admitted patients of PICU, Mashhad- Iran.Materials and Methods: In this study, 100 patients admitted in PICU divided into two equal groups on the first day of admission. They received ranitidine or pantoprazole as prophylaxis of stress ulcer. Those patients who had history of gastrointestinal bleeding or coagulation disorder were excluded. 100 PICU patients who had not received prophylaxis during last 6 months retrospectively evaluated as control of the study. Data were collected as demographic characteristics, admission reason, definitive diagnosis, receiving corticosteroid and mechanical ventilation in each patient. Gastrointestinal bleeding (hematemesis, coffee ground aspirate, and melena and clinically significant gastrointestinal bleeding were daily monitored. Data analyzed through descriptive statistical tests, Chi-square, logistic regression, t-test and using SPSS-16 software.Results: Among 204 patients (control group=105 and case group=99, incidence of gastrointestinal bleeding (GB was 13.2% in which 6.9% of cases presented with clinically significant gastrointestinal bleeding (CSGB. Loss of consciousness and respiratory distress were the main reason of admission. There was no significant differences between the incidence of (GB and (CSGB in experimental and control groups (P>0.05 as well as ranitidine and pantoprazole prophylaxis (P>0.05. Significant risk factors of (GB were mechanical ventilation and loss of consciousness and corticosteroid therapy

  4. Incidence of acute kidney injury in the neonatal intensive care unit.

    Science.gov (United States)

    Youssef, Doaa; Abd-Elrahman, Hadeel; Shehab, Mohamed M; Abd-Elrheem, Mohamed

    2015-01-01

    The aim of this work is to study the incidence of acute kidney injury (AKI) in neonates admitted to the neonatal intensive care unit (NICU) over a six-month period from September 2011 to March 2012. This prospective study was performed on 250 neonates admitted to the NICU at the Children's Hospital, Faculty of Medicine, Zagazig University. All neonates were subjected to detailed history taking, including pre-natal, natal and post-natal history, with stress on symptoms suggestive of AKI. All neonates were examined thoroughly and the following investigations were performed: Blood urea nitrogen (BUN), serum creatinine, sodium, potassium, calcium, complete blood count, C-reactive protein, arterial blood gases, urine sodium and urine creatinine. AKI was diagnosed in 27 cases (10.8%), including 12 females and 15 males. 40.7% of the AKI cases were born after full-term pregnancy while 59.3% were pre-term babies. 29.6% of the AKI cases had oliguria, and there was male sex predominance, with a male-female ratio of 1.3:1. The cause of AKI was pre-renal in 96.3% and intrinsic renal in 3.7% of the cases. The predisposing factors for AKI were sepsis in 63% of the cases, respiratory distress syndrome in 55.6%, mechanical ventilation in 51.9%, peri-natal asphyxia in 18.5%, dehydration in 14.8%, surgical operation in 11.1%, congenital heart disease in 7.4%, sub-galeal hematoma in 3.7%, polycythemia in 3.7% and intra-ventricular hemorrhage in 3.7% of the cases. Our data suggest that pre-renal failure was the most common form of AKI in our patients. Early recognition of risk factors such as sepsis, peri-natal asphyxia or peri-operative problems and rapid effective treatment of contributing conditions will reduce the incidence of AKI in the neonatal period.

  5. Dynamics of atomic clusters in intense optical fields of ultrashort ...

    Indian Academy of Sciences (India)

    J. Chem. Sci. Vol. 124, No. 1, January 2012, pp. 75–81. c Indian Academy of Sciences. ... Consequently, exposure of atoms and molecules to such intense pulses inevitably leads to single and multiple ... Coulomb explosion, giving rise to ejection of fast Ar-ions. .... intense laser pulses of only a few femtoseconds dura-.

  6. Characteristic Analysis Light Intensity Sensor Based On Plastic Optical Fiber At Various Configuration

    Science.gov (United States)

    Arifin, A.; Lusiana; Yunus, Muhammad; Dewang, Syamsir

    2018-03-01

    This research discusses the light intensity sensor based on plastic optical fiber. This light intensity sensor is made of plastic optical fiber consisting of two types, namely which is cladding and without cladding. Plastic optical fiber used multi-mode step-index type made of polymethyl metacrylate (PMMA). The infrared LED emits light into the optical fiber of the plastic and is subsequently received by the phototransistor to be converted to an electric voltage. The sensor configuration is made with three models: straight configuration, U configuration and gamma configuration with cladding and without cladding. The measured light source uses a 30 Watt high power LED with a light intensity of 0 to 10 Klux. The measured light intensity will affect the propagation of light inside the optical fiber sensor. The greater the intensity of the measured light, the greater the output voltage that is read on the computer. The results showed that the best optical fiber sensor characteristics were obtained in U configuration. Sensors with U-configuration without cladding had the best sensitivity and resolution values of 0.0307 volts/Klux and 0.0326 Klux. The advantages of this measuring light intensity based on the plastic optical fiber instrument are simple, easy-to-make operational systems, low cost, high sensitivity and resolution.

  7. Fiber-optical sensor with intensity compensation model in college teaching of physics experiment

    Science.gov (United States)

    Su, Liping; Zhang, Yang; Li, Kun; Zhang, Yu

    2017-08-01

    Optical fiber sensor technology is one of the main contents of modern information technology, which has a very important position in modern science and technology. Fiber optic sensor experiment can improve students' enthusiasm and broaden their horizons in college physics experiment. In this paper the main structure and working principle of fiberoptical sensor with intensity compensation model are introduced. And thus fiber-optical sensor with intensity compensation model is applied to measure micro displacement of Young's modulus measurement experiment and metal linear expansion coefficient measurement experiment in the college physics experiment. Results indicate that the measurement accuracy of micro displacement is higher than that of the traditional methods using fiber-optical sensor with intensity compensation model. Meanwhile this measurement method makes the students understand on the optical fiber, sensor and nature of micro displacement measurement method and makes each experiment strengthen relationship and compatibility, which provides a new idea for the reform of experimental teaching.

  8. Finite-mode analysis by means of intensity information in fractional optical systems

    NARCIS (Netherlands)

    Alieva, T.; Bastiaans, M.J.

    2002-01-01

    It is shown how a coherent optical signal that contains only a finite number of Hermite-Gauss modes, can be reconstructed from the knowledge of its Radon-Wigner transform -- associated with the intensity distribution in a fractional Fourier transform optical system -- at only two transversal points.

  9. Incidence of acute kidney injury in the neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Doaa Youssef

    2015-01-01

    Full Text Available The aim of this work is to study the incidence of acute kidney injury (AKI in neonates admitted to the neonatal intensive care unit (NICU over a six-month period from September 2011 to March 2012. This prospective study was performed on 250 neonates admitted to the NICU at the Children′s Hospital, Faculty of Medicine, Zagazig University. All neonates were subjected to detailed history taking, including pre-natal, natal and post-natal history, with stress on symptoms suggestive of AKI. All neonates were examined thoroughly and the following investigations were performed: Blood urea nitrogen (BUN, serum creatinine, sodium, potassium, calcium, complete blood count, C-reactive protein, arterial blood gases, urine sodium and urine creatinine. AKI was diagnosed in 27 cases (10.8%, including 12 females and 15 males. 40.7% of the AKI cases were born after full-term pregnancy while 59.3% were pre-term babies. 29.6% of the AKI cases had oliguria, and there was male sex predominance, with a male-female ratio of 1.3:1. The cause of AKI was pre-renal in 96.3% and intrinsic renal in 3.7% of the cases. The predisposing factors for AKI were sepsis in 63% of the cases, respiratory distress syndrome in 55.6%, mechanical ventilation in 51.9%, peri-natal asphyxia in 18.5%, dehydration in 14.8%, surgical operation in 11.1%, congenital heart disease in 7.4%, sub-galeal hematoma in 3.7%, polycythemia in 3.7% and intra-ventricular hemorrhage in 3.7% of the cases. Our data suggest that pre-renal failure was the most common form of AKI in our patients. Early recognition of risk factors such as sepsis, peri-natal asphyxia or peri-operative problems and rapid effective treatment of contributing conditions will reduce the incidence of AKI in the neonatal period.

  10. Quantum reconstruction of an intense polarization squeezed optical state

    DEFF Research Database (Denmark)

    Marquardt, Ch.; Heersink, J.; Dong, R.

    2007-01-01

    We perform a reconstruction of the polarization sector of the density matrix of an intense polarization squeezed beam starting from a complete set of Stokes measurements. By using an appropriate quasidistribution, we map this onto the Poincare space, providing a full quantum mechanical characteri...

  11. Calculating computer-generated optical elements to produce arbitrary intensity distributions

    International Nuclear Information System (INIS)

    Findlay, S.; Nugent, K.A.; Scholten, R.E.

    2000-01-01

    Full text: We describe preliminary investigation into using a computer to generate optical elements (CGOEs) with phase-only variation, that will produce an arbitrary intensity distribution in a given image plane. An iterative calculation cycles between the CGOE and the image plane and modifies each according to the appropriate constraints. We extend this to the calculation of defined intensity distributions in two separated planes by modifying both phase and intensity at the CGOE

  12. A beam intensity monitor for the evaluation beamline for soft x-ray optical elements

    International Nuclear Information System (INIS)

    Imazono, Takashi; Moriya, Naoji; Harada, Yoshihisa; Sano, Kazuo; Koike, Masato

    2012-01-01

    Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam intensity monitor that has been equipped in BL-11 has observed the signal of the zero-th order light. For the purpose of more accurate evaluation of the performance of optical components, a new beam intensity monitor to measure the intensity of the first order light from the monochromator in BL-11 has been developed and installed in just front of RD. The strong positive correlation between the signal of the beam monitor and a detector equipped in the RD is shown. It is successful that the beam intensity of the first order light can be monitored in real time.

  13. Optical Intensity Modulation in an LiNbO3 Slab-Coupled Waveguide

    Directory of Open Access Journals (Sweden)

    Yalin Lu

    2008-01-01

    Full Text Available Optical intensity modulation has been demonstrated through switching the optical beam between the main core waveguide and a closely attached leaky slab waveguide by applying a low-voltage electrical field. Theory for simulating such an LiNbO3 slab-coupled waveguide structure was suggested, and the result indicates the possibility of making the spatial guiding mode large, circular and symmetric, which further allows the potential to significantly reduce the coupling losses with adjacent lasers and optical networks. Optical intensity modulation using electro-optic effect was experimentally demonstrated in a 5 cm long waveguide fabricated by using a procedure of soft proton exchange and then an overgrowth of thin LN film on top of a c-cut LiNbO3 wafer.

  14. Ultra-fine metal gate operated graphene optical intensity modulator

    Science.gov (United States)

    Kou, Rai; Hori, Yosuke; Tsuchizawa, Tai; Warabi, Kaori; Kobayashi, Yuzuki; Harada, Yuichi; Hibino, Hiroki; Yamamoto, Tsuyoshi; Nakajima, Hirochika; Yamada, Koji

    2016-12-01

    A graphene based top-gate optical modulator on a standard silicon photonic platform is proposed for the future optical telecommunication networks. On the basis of the device simulation, we proposed that an electro-absorption light modulation can be realized by an ultra-narrow metal top-gate electrode (width less than 400 nm) directly located on the top of a silicon wire waveguide. The designed structure also provides excellent features such as carrier doping and waveguide-planarization free fabrication processes. In terms of the fabrication, we established transferring of a CVD-grown mono-layer graphene sheet onto a CMOS compatible silicon photonic sample followed by a 25-nm thick ALD-grown Al2O3 deposition and Source-Gate-Drain electrodes formation. In addition, a pair of low-loss spot-size converter for the input and output area is integrated for the efficient light source coupling. The maximum modulation depth of over 30% (1.2 dB) is observed at a device length of 50 μm, and a metal width of 300 nm. The influence of the initial Fermi energy obtained by experiment on the modulation performance is discussed with simulation results.

  15. Post-Cataract Surgery Optic Neuropathy: Prevalence, Incidence, Temporal Relationship, and Fellow Eye Involvement.

    Science.gov (United States)

    Moradi, Ahmadreza; Kanagalingam, Sivashakthi; Diener-West, Marie; Miller, Neil R

    2017-03-01

    To reassess the prevalence and incidence of post-cataract surgery optic neuropathy (PCSON) in the modern era. Retrospective cohort study. Setting: Single-center tertiary care practice. All patients with a diagnosis of nonarteritic anterior ischemic optic neuropathy (NAION) seen in the Wilmer Eye Network system between January 1, 2010 and December 31, 2014 were included. Inclusion was based on the following: (1) a history of an acute unilateral decrease in vision, (2) a visual field defect consistent with NAION, (3) a relative afferent pupillary defect, (4) observed optic disc swelling, and (5) no other etiology being found. The prevalence and incidence of PCSON and the temporal association between surgery and onset of PCSON. The secondary outcome was the risk of PCSON in the fellow eye of patients with prior unilateral spontaneous NAION. One hundred eighty-eight patients had developed NAION during the study period. Of these, 18 (9.6%) had undergone cataract surgery (CS) during the year prior to developing NAION. There was no significant temporal pattern associated with the distribution of NAION cases (P = .28). The incidence of PCSON in patients who had noncomplex CS was 10.9 cases per 100 000 (95% CI, 1.3, 39.4). Our data indicate that both the prevalence and incidence of NAION after modern CS are comparable to those of the general population and that there is no significant temporal relationship between modern CS and the subsequent development of NAION in the operated eye. Thus, although this study has inherent biases owing to its retrospective nature, concern regarding an increased risk of PCSON in the fellow eye in patients who have experienced it or spontaneous NAION in 1 eye may be unwarranted. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Partially coherent X-ray wavefront propagation simulations including grazing-incidence focusing optics.

    Science.gov (United States)

    Canestrari, Niccolo; Chubar, Oleg; Reininger, Ruben

    2014-09-01

    X-ray beamlines in modern synchrotron radiation sources make extensive use of grazing-incidence reflective optics, in particular Kirkpatrick-Baez elliptical mirror systems. These systems can focus the incoming X-rays down to nanometer-scale spot sizes while maintaining relatively large acceptance apertures and high flux in the focused radiation spots. In low-emittance storage rings and in free-electron lasers such systems are used with partially or even nearly fully coherent X-ray beams and often target diffraction-limited resolution. Therefore, their accurate simulation and modeling has to be performed within the framework of wave optics. Here the implementation and benchmarking of a wave-optics method for the simulation of grazing-incidence mirrors based on the local stationary-phase approximation or, in other words, the local propagation of the radiation electric field along geometrical rays, is described. The proposed method is CPU-efficient and fully compatible with the numerical methods of Fourier optics. It has been implemented in the Synchrotron Radiation Workshop (SRW) computer code and extensively tested against the geometrical ray-tracing code SHADOW. The test simulations have been performed for cases without and with diffraction at mirror apertures, including cases where the grazing-incidence mirrors can be hardly approximated by ideal lenses. Good agreement between the SRW and SHADOW simulation results is observed in the cases without diffraction. The differences between the simulation results obtained by the two codes in diffraction-dominated cases for illumination with fully or partially coherent radiation are analyzed and interpreted. The application of the new method for the simulation of wavefront propagation through a high-resolution X-ray microspectroscopy beamline at the National Synchrotron Light Source II (Brookhaven National Laboratory, USA) is demonstrated.

  17. Optical nonclassicality test based on third-order intensity correlations

    Science.gov (United States)

    Rigovacca, L.; Kolthammer, W. S.; Di Franco, C.; Kim, M. S.

    2018-03-01

    We develop a nonclassicality criterion for the interference of three delayed, but otherwise identical, light fields in a three-mode Bell interferometer. We do so by comparing the prediction of quantum mechanics with those of a classical framework in which independent sources emit electric fields with random phases. In particular, we evaluate third-order correlations among output intensities as a function of the delays, and show how the presence of a correlation revival for small delays cannot be explained by the classical model of light. The observation of a revival is thus a nonclassicality signature, which can be achieved only by sources with a photon-number statistics that is highly sub-Poissonian. Our analysis provides strong evidence for the nonclassicality of the experiment discussed by Menssen et al. [Phys. Rev. Lett. 118, 153603 (2017), 10.1103/PhysRevLett.118.153603], and shows how a collective "triad" phase affects the interference of any three or more light fields, irrespective of their quantum or classical character.

  18. Persistent postoperative pain after cardiac surgery: a systematic review with meta-analysis regarding incidence and pain intensity.

    Science.gov (United States)

    Guimarães-Pereira, Luís; Reis, Pedro; Abelha, Fernando; Azevedo, Luís Filipe; Castro-Lopes, José Manuel

    2017-10-01

    Persistent postoperative pain (PPP) has been described as a complication of cardiac surgery (CS). We aimed to study PPP after CS (PPPCS) by conducting a systematic review of the literature regarding its incidence, intensity, location, and the presence of neuropathic pain, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. The review comprised 3 phases: a methodological assessment of 6 different databases identifying potential articles and screening for inclusion criteria by 2 independent reviewers; data extraction; and study quality assessment. Meta-analysis was used to estimate the pooled incidence rates using a random effects model. We have identified 442 potentially relevant studies through database searching. A total of 23 studies (involving 11,057 patients) met our inclusion criteria. Persistent postoperative pain affects 37% patients in the first 6 months after CS, and it remains present more than 2 years after CS in 17%. The reported incidence of PPP during the first 6 months after CS increased in recent years. Globally, approximately half of the patients with PPPCS reported moderate to severe pain. Chest is the main location of PPPCS followed by the leg; neuropathic pain is present in the majority of the patients. This is the first systematic review and meta-analysis to provide estimates regarding incidence and intensity of PPPCS, which elucidates its relevance. There is an urgent need for adequate treatment and follow-up in patients with PPPCS.

  19. Selective detection of Escherichia coli by imaging of the light intensity transmitted through an optical disk

    Science.gov (United States)

    Shiramizu, Hideyuki; Kuroda, Chiaki; Ohki, Yoshimichi; Shima, Takayuki; Wang, Xiaomin; Fujimaki, Makoto

    2018-03-01

    We have developed an optical disk system for imaging transmitted light from Escherichia coli dispersed on an optical disk. When E. coli was stained using Bismarck brown, the transmittance was found to decrease in images obtained at λ = 405 nm. The results indicate that transmittance imaging is suitable for finding the difference in light intensity between stained and unstained E. coli, whereas the reflectance images were scarcely changed by staining. Therefore, E. coli can be selectively discriminated from abiotic contaminants using transmittance imaging.

  20. Influences of optical-spectrum errors on excess relative intensity noise in a fiber-optic gyroscope

    Science.gov (United States)

    Zheng, Yue; Zhang, Chunxi; Li, Lijing

    2018-03-01

    The excess relative intensity noise (RIN) generated from broadband sources degrades the angular-random-walk performance of a fiber-optic gyroscope dramatically. Many methods have been proposed and managed to suppress the excess RIN. However, the properties of the excess RIN under the influences of different optical errors in the fiber-optic gyroscope have not been systematically investigated. Therefore, it is difficult for the existing RIN-suppression methods to achieve the optimal results in practice. In this work, the influences of different optical-spectrum errors on the power spectral density of the excess RIN are theoretically analyzed. In particular, the properties of the excess RIN affected by the raised-cosine-type ripples in the optical spectrum are elaborately investigated. Experimental measurements of the excess RIN corresponding to different optical-spectrum errors are in good agreement with our theoretical analysis, demonstrating its validity. This work provides a comprehensive understanding of the properties of the excess RIN under the influences of different optical-spectrum errors. Potentially, it can be utilized to optimize the configurations of the existing RIN-suppression methods by accurately evaluating the power spectral density of the excess RIN.

  1. Intensity stabilisation of optical pulse sequences for coherent control of laser-driven qubits

    Science.gov (United States)

    Thom, Joseph; Yuen, Ben; Wilpers, Guido; Riis, Erling; Sinclair, Alastair G.

    2018-05-01

    We demonstrate a system for intensity stabilisation of optical pulse sequences used in laser-driven quantum control of trapped ions. Intensity instability is minimised by active stabilisation of the power (over a dynamic range of > 104) and position of the focused beam at the ion. The fractional Allan deviations in power were found to be logic gates to be below 10^{-6} per gate.

  2. The role of surface topography in predicting scattering at grazing incidence from optical surfaces

    International Nuclear Information System (INIS)

    Rehn, V.; Jones, V.O.; Elson, J.M.; Bennett, J.M.

    1980-01-01

    Monochromator design and the design of optical experiments at XUV and X-ray wavelengths are frequently limited by scattering from optical components, yet theoretical treatments are few and untested experimentally. This is partly due to the failure of scattering models used in the visible and near UV when the wavelength becomes comparable to, or smaller than, the topographic features on the surface, and partly it is due to the difficulty in measuring the topography on the required size scale. We briefly review the theoretical problems and prospects for accurately predicting both the magnitude and angular distribution of scattering at grazing incidence from optical surfaces. Experimental methods for determining and representing the surface topography are also reviewed, together with their limitations and ranges of applicability. Finally, the first results of our experiments, conducted recently at the Stanford Synchrotron Radiation Laboratory on the angular distribution of scattering by surfaces of known topography are presented and discussed, along with their potential implications for the theory of scattering, and for XUV and X-ray optical components. (orig.)

  3. Incidence of enhancement of the optic nerve/sheath complex in fat-suppression orbit MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Kyu; Yoon, Kwon Ha; Choi, Choong Gon; Suh, Dae Chul [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-04-15

    To elucidate the incidence of Gd-DTPA enhancement of the optic nerve/sheath complex (ONC) in patients with various ophthalmopathies using fat-suppression MRI. Orbit MRI with fat-suppression technique (ChemSat) was performed in 58 patients with normal and various orbital lesions. The fat-suppression MR was done with and without Gd-DTPA injection in all cases. MR findings were reviewed retrospectively in a blind fashion with respect to presence or absence of contrast enhancement of the ONC. Contrast enhancement of the ONC was seen in 86% (6/7) of cavernous sinus lesions, 80% (8/10) of intraconal lesions excluding the ONC, 57% (16/28) of ONC lesions, 38% (3/8) of ocular lesions, and 2% (1/55) of normal orbits. The ONC enhancement was the most common in optic nerve/sheath tumors (10/10), and pseudotumors (6/6), cavernous sinus dural arteriovenous malformations (3/3) and cavernous sinus thrombosis (2/2), and less frequently seen in optic neuritis (3/14). Enhancement of the ONC may be seen in lesions of the cavernous sinus and orbit other than optic nerve/sheath lesion.

  4. Simple method based on intensity measurements for characterization of aberrations from micro-optical components.

    Science.gov (United States)

    Perrin, Stephane; Baranski, Maciej; Froehly, Luc; Albero, Jorge; Passilly, Nicolas; Gorecki, Christophe

    2015-11-01

    We report a simple method, based on intensity measurements, for the characterization of the wavefront and aberrations produced by micro-optical focusing elements. This method employs the setup presented earlier in [Opt. Express 22, 13202 (2014)] for measurements of the 3D point spread function, on which a basic phase-retrieval algorithm is applied. This combination allows for retrieval of the wavefront generated by the micro-optical element and, in addition, quantification of the optical aberrations through the wavefront decomposition with Zernike polynomials. The optical setup requires only an in-motion imaging system. The technique, adapted for the optimization of micro-optical component fabrication, is demonstrated by characterizing a planoconvex microlens.

  5. Symmetry consideration in zero loop-area Sagnac interferometry at oblique incidence for detecting magneto-optic Kerr effects.

    Science.gov (United States)

    Zhu, X D

    2017-08-01

    I present a detailed account of a zero loop-area Sagnac interferometer operated at oblique incidence for detecting magneto-optic Kerr effects arising from a magnetized sample. In particular, I describe the symmetry consideration and various optical arrangements available to such an interferometer that enables measurements of magneto-optic effects due to both in-plane and out-of-plane magnetization of the sample with optimizable signal-to-noise ratios.

  6. Harvest intensity and competition control impacts on loblolly pine fusiform rust incidence

    Science.gov (United States)

    Robert J. Eaton; Paula Spaine; Felipe G. Sanchez

    2006-01-01

    The Long Term Soil Productivity experiment tests the effects of soil compaction, surface organic matter removal, and understory control on net primary productivity. An unintended consequence of these treatments may be an effect on the incidence of fusiform rust [Cronartium quercuum (Berk.) Miy. ex Shirai f. sp. fusiforme Burdsall et Snow]. Loblolly pine (Pinus...

  7. Incidence of nonarteritic anterior ischemic optic neuropathy: increased risk among diabetic patients

    Science.gov (United States)

    Lee, Michael S; Grossman, Daniel; Arnold, Anthony C.; Sloan, Frank A

    2011-01-01

    Objective Previous studies have identified a higher prevalence of diabetes mellitus (DM) among patient cohorts with non-arteritic anterior ischemic optic neuropathy (NAION). We sought to determine the development of incident NAION among a group of newly diagnosed patients with DM and to estimate the incidence of NAION among the elderly. Design Medicare 5% database study. Participants 25,515 patients with DM and an equal number of age- and gender-matched non-diabetics. Methods Query of Medicare 5% claims files identified patients with new diagnosis of DM in 1994. A randomly selected control group was created using one-to-one propensity score matching. Patients with a diagnosis of giant cell arteritis, pre-existing DM, and age 95 years were excluded. Patients with DM and controls were followed for the development of NAION over the following 4,745 days. Main Outcome Measures Incidence of anterior ischemic optic neuropathy (AION) among patients with and without DM. Results Each group was 85% White, 11% Black, and 4% other race, aged 76.4 years, and 40% male with a mean followup time of 7.6 years. In the diabetes group, 188 individuals developed AION (0.7%) compared to 131 individuals (0.5%; p<0.01) in the control group. In unadjusted Cox regression analysis, having diabetes mellitus was associated with a 43% increased risk (Hazard ratio [HR]: 1.431; 95% confidence interval [CI]: 1.145,1.789) of developing AION. After adjusting for other covariates, the risk of developing AION among individuals with DM was reduced to 40% (HR: 1.397; 95% CI: 1.115,1.750). Male gender increased an individual's risk of developing AION by 32% (HR: 1.319; 95% CI: 1.052,1.654). No other covariate was statistically significantly associated with developing AION. The annual incidence of NAION was 82 per 100,000. Conclusions DM significantly increased the risk of the diagnosis NAION. The incidence of NAION among patients older than 67 years may be higher than previously reported. PMID:21439645

  8. Respiration rate detection based on intensity modulation using plastic optical fiber

    Science.gov (United States)

    Anwar, Zawawi Mohd; Ziran Nurul Sufia, Nor; Hadi, Manap

    2017-11-01

    This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  9. Excitation of random intense single-cycle light-pulse chains in optical fiber

    International Nuclear Information System (INIS)

    Ding, Y C; Zhang, F L; Gao, J B; Chen, Z Y; Lin, C Y; Yu, M Y

    2014-01-01

    Excitation of intense periodic single-cycle light pulses in a stochastic background arising from continuous wave stimulated Brillouin scattering (SBS) in a long optical fiber with weak optical feedback is found experimentally and modeled theoretically. Such intense light-pulse chains occur randomly and the optical feedback is a requirement for their excitation. The probability of these forms, among the large number of experimental output signals with identifiable waveforms, appearing is only about 3%, with the remainder exhibiting regular SBS characteristics. It is also found that pulses with low period numbers appear more frequently and the probability distribution for their occurrence in terms of the pulse power is roughly L-shaped, like that for rogue waves. The results from a three-wave-coupling model for SBS including feedback phase control agree well qualitatively with the observed phenomena. (paper)

  10. Respiration rate detection based on intensity modulation using plastic optical fiber

    Directory of Open Access Journals (Sweden)

    Mohd Anwar Zawawi

    2017-01-01

    Full Text Available This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  11. All-optical universal logic gates on nonlinear multimode interference coupler using tunable input intensity

    Science.gov (United States)

    Tajaldini, Mehdi; Jafri, Mohd Zubir Mat

    2015-04-01

    The theory of Nonlinear Modal Propagation Analysis Method (NMPA) have shown significant features of nonlinear multimode interference (MMI) coupler with compact dimension and when launched near the threshold of nonlinearity. Moreover, NMPA have the potential to allow studying the nonlinear MMI based the modal interference to explorer the phenomenon that what happen due to the natural of multimode region. Proposal of all-optical switch based NMPA has approved its capability to achieving the all-optical gates. All-optical gates have attracted increasing attention due to their practical utility in all-optical signal processing networks and systems. Nonlinear multimode interference devices could apply as universal all-optical gates due to significant features that NMPA introduce them. In this Paper, we present a novel Ultra-compact MMI coupler based on NMPA method in low intensity compared to last reports either as a novel design method and potential application for optical NAND, NOR as universal gates on single structure for Boolean logic signal processing devices and optimize their application via studding the contrast ratio between ON and OFF as a function of output width. We have applied NMPA for several applications so that the miniaturization in low nonlinear intensities is their main purpose.

  12. Third-order optical intensity correlation measurements of pseudo-thermal light

    International Nuclear Information System (INIS)

    Chen Xi-Hao; Wu Wei; Meng Shao-Ying; Li Ming-Fei

    2014-01-01

    Third-order Hanbrury Brown—Twiss and double-slit interference experiments with a pseudo-thermal light are performed by recording intensities in single, double and triple optical paths, respectively. The experimental results verifies the theoretical prediction that the indispensable condition for achieving a interference pattern or ghost image in Nth-order intensity correlation measurements is the synchronous detection of the same light field by each reference detector, no matter the intensities recorded in one, or two, or N optical paths. It is shown that, when the reference detectors are scanned in the opposite directions, the visibility and resolution of the third-order spatial correlation function of thermal light is much better than that scanned in the same direction, but it is no use for obtaining the Nth-order interference pattern or ghost image in the thermal Nth-order interference or ghost imaging. (general)

  13. Suppression of Helicobacter pylori infection during intensive care stay: related to stress ulcer bleeding incidence?

    NARCIS (Netherlands)

    van der Voort, P. H.; van der Hulst, R. W.; Zandstra, D. F.; Geraedts, A. A.; van der Ende, A.; Tytgat, G. N.

    2001-01-01

    PURPOSE: To assess the prevalence of active Helicobacter pylori infection in patients admitted to the intensive care unit, to determine the effect of selective gut decontamination on the persistence of this organism, and to explore the possible relationship between H. pylori infection and stress

  14. A novel optic bistable device with very low threshold intensity using photorefractive films

    Science.gov (United States)

    Wang, Sean X.; Sun, Yuankun; Trivedi, Sudhir B.; Li, Guifang

    1994-08-01

    Brimrose Corporation of America reports the successful completion of the SBIR Phase I research in low-threshold intensity optical bistable devices using photorefractive nonlinearity. A thin photorefractive film optical bistable device was proposed in the Phase I proposal. The feasibility of this device was theoretically investigated. The theoretical feasibility study formulates the materials requirements in such a kind of configuration for Phase II research. In addition, we have proposed and investigated another configuration of optical bistable devices that do not require advanced photorefractive materials, namely, the self-pumped phase conjugator. We have successfully demonstrated a low-threshold optical bistable operation in a KNSBN:CU crystal. To the best of our knowledge, the threshold of 650 mW/sq. cm is the lowest of its kind to be achieved so far.

  15. The impact of normal saline on the incidence of exposure keratopathy in patients hospitalized in intensive care units

    Directory of Open Access Journals (Sweden)

    Zohreh Davoodabady

    2018-01-01

    Full Text Available Background: Patients in the intensive care unit (ICU have impaired ocular protective mechanisms that lead to an increased risk of ocular surface diseases including exposure keratopathy (EK. This study was designed to evaluate the effect of normal saline (NS on the incidence and severity of EK in critically ill patients. Materials and Methods: This single-blind randomized controlled trial was conducted on 50 patients admitted to ICUs. The participants were selected through purposive sampling. One eye of each patient, randomly was allocated to intervention group (standard care with NS and the other eye to control group (standard care. In each patient, one eye (control group randomly received standard care and the other eye (intervention group received NS every 6 h in addition to standard care. The presence and severity of keratopathy was assessed daily until day 7 of hospitalization using fluorescein and an ophthalmoscope with cobalt blue filter. Chi-square test was used for statistical analysis in SPSS software. Results: Before the study ( first day there were no statistically significant differences in the incidence and severity of EK between groups. Although, the incidence and severity of EK after the study (7th day was higher in the intervention group compared to the control group, their differences were not statistically significant. Although, the incidence and severity of EK, from the 1st day until the 7th, increased within both groups, this increase was statistically significant only in the intervention (NS group. Conclusions: The use of NS as eye care in patients hospitalized in ICUs can increase the incidence and severity of EK and is not recommended.

  16. Effect of nocturnal sound reduction on the incidence of delirium in intensive care unit patients: An interrupted time series analysis.

    Science.gov (United States)

    van de Pol, Ineke; van Iterson, Mat; Maaskant, Jolanda

    2017-08-01

    Delirium in critically-ill patients is a common multifactorial disorder that is associated with various negative outcomes. It is assumed that sleep disturbances can result in an increased risk of delirium. This study hypothesized that implementing a protocol that reduces overall nocturnal sound levels improves quality of sleep and reduces the incidence of delirium in Intensive Care Unit (ICU) patients. This interrupted time series study was performed in an adult mixed medical and surgical 24-bed ICU. A pre-intervention group of 211 patients was compared with a post-intervention group of 210 patients after implementation of a nocturnal sound-reduction protocol. Primary outcome measures were incidence of delirium, measured by the Intensive Care Delirium Screening Checklist (ICDSC) and quality of sleep, measured by the Richards-Campbell Sleep Questionnaire (RCSQ). Secondary outcome measures were use of sleep-inducing medication, delirium treatment medication, and patient-perceived nocturnal noise. A significant difference in slope in the percentage of delirium was observed between the pre- and post-intervention periods (-3.7% per time period, p=0.02). Quality of sleep was unaffected (0.3 per time period, p=0.85). The post-intervention group used significantly less sleep-inducing medication (psound-reduction protocol. However, reported sleep quality did not improve. Copyright © 2017. Published by Elsevier Ltd.

  17. The incidence rate and mortality of malignant brain tumors after 10 years of intensive cell phone use in Taiwan.

    Science.gov (United States)

    Hsu, Min-Huei; Syed-Abdul, Shabbir; Scholl, Jeremiah; Jian, Wen-Shan; Lee, Peisan; Iqbal, Usman; Li, Yu-Chuan

    2013-11-01

    The issue of whether cell phone usage can contribute toward the development of brain tumors has recently been reignited with the International Agency for Research on Cancer classifying radiofrequency electromagnetic fields as 'possibly' carcinogenic to humans in a WHO report. To our knowledge, this is the largest study reporting on the incidence and mortality of malignant brain tumors after long-term use of the cell phone by more than 23 million users. A population-based study was carried out the numbers of cell phone users were collected from the official statistics provided by the National Communication Commission. According to National Cancer Registry, there were 4 incidences and 4 deaths due to malignant neoplasms in Taiwan during the period 2000-2009. The 10 years of observational data show that the intensive user rate of cell phones has had no significant effect on the incidence rate or on the mortality of malignant brain tumors in Taiwan. In conclusion, we do not detect any correlation between the morbidity/mortality of malignant brain tumors and cell phone use in Taiwan. We thus urge international agencies to publish only confirmatory reports with more applicable conclusions in public. This will help spare the public from unnecessary worries.

  18. Secondary scattering on the intensity dependence of the capture velocity in a magneto-optical trap

    International Nuclear Information System (INIS)

    Loos, M.R.; Massardo, S.B.; Zanon, R.A. de S; Oliveira, A.L. de

    2005-01-01

    In this work, we consider a three-dimensional model to simulate the capture velocity behavior in a sample of cold-trapped sodium atoms as a function of the trapping laser intensity. We expand on previous work [V. S. Bagnato, L. G. Marcassa, S. G. Miranda, S. R. Muniz, and A. L. de Oliveira, Phys. Rev. A 62, 013404 (2000)] by calculating the capture velocity over a broad range of light intensities considering the secondary scattering in a magneto-optical trap. Our calculations are in a good agreement with recent measured values [S. R. Muniz et al., Phys. Rev. A 65, 015402 (2001)

  19. Secondary scattering on the intensity dependence of the capture velocity in a magneto-optical trap

    Science.gov (United States)

    Loos, M. R.; Massardo, S. B.; de S. Zanon, R. A.; de Oliveira, A. L.

    2005-08-01

    In this work, we consider a three-dimensional model to simulate the capture velocity behavior in a sample of cold-trapped sodium atoms as a function of the trapping laser intensity. We expand on previous work [V. S. Bagnato, L. G. Marcassa, S. G. Miranda, S. R. Muniz, and A. L. de Oliveira, Phys. Rev. A 62, 013404 (2000)] by calculating the capture velocity over a broad range of light intensities considering the secondary scattering in a magneto-optical trap. Our calculations are in a good agreement with recent measured values [S. R. Muniz , Phys. Rev. A 65, 015402 (2001)].

  20. Effect of substrate material selection on polychromatic integral diffraction efficiency for multilayer diffractive optics in oblique incident situation

    Science.gov (United States)

    Zhang, Bo; Cui, Qingfeng; Piao, Mingxu

    2018-05-01

    The effect of substrate material selection for multilayer diffractive optical elements (MLDOEs) on polychromatic integral diffraction efficiency (PIDE) is studied in the oblique incident situation. A mathematical model of substrate material selection is proposed to obtain the high PIDE with large incident angle. The extended expression of the microstructure heights with consideration of incident angle is deduced to calculate the PIDE difference Δ η bar(λ) for different substrate material combinations. The smaller value of Δ η bar(λ) indicates the more optimal substrate material combination in a wide incident angle range. Based on the deduced mathematical model, different MLDOEs are analyzed in visible and infrared wavebands. The results show that the three-layer DOEs can be applied in larger incident angle situation than the double-layer DOEs in visible waveband. When the two substrate materials are the same, polycarbonate (PC) is more reasonable than poly(methyl methacrylate) (PMMA) as the middle filling optical material for the three-layer DOEs. In the infrared waveband, the PIDE decreases in the LWIR are obviously smaller than that in the MWIR for the same substrate material combination, and the PIDE cannot be calculated when the incident angle larger than critical angle. The analysis results can be used to guide the hybrid optical system design with MLDOEs.

  1. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    International Nuclear Information System (INIS)

    Fiorella, D.; Helms, C.A.; Speer, K.P.

    2000-01-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  2. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiorella, D.; Helms, C.A. [Dept. of Radiology, Duke Univ., Durham, NC (United States); Speer, K.P. [Dept. of Orthopedic Surgery, Duke Univ., Durham, NC (United States)

    2000-12-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  3. Limit on Excitation and Stabilization of Atoms in Intense Optical Laser Fields.

    Science.gov (United States)

    Zimmermann, H; Meise, S; Khujakulov, A; Magaña, A; Saenz, A; Eichmann, U

    2018-03-23

    Atomic excitation in strong optical laser fields has been found to take place even at intensities exceeding saturation. The concomitant acceleration of the atom in the focused laser field has been considered a strong link to, if not proof of, the existence of the so-called Kramers-Henneberger (KH) atom, a bound atomic system in an intense laser field. Recent findings have moved the importance of the KH atom from being purely of theoretical interest toward real world applications; for instance, in the context of laser filamentation. Considering this increasing importance, we explore the limits of strong-field excitation in optical fields, which are basically imposed by ionization through the spatial field envelope and the field propagation.

  4. Virtual-anode formation by an intense pulsed ion beam incident upon a magnetic barrier

    International Nuclear Information System (INIS)

    Robertson, S.; Wessel, F.

    1980-01-01

    An intense, pulsed, initially space-charge-neutral ion beam (100 kV, 1 kA, 600 nsec) has been propagated into a transversely oriented magnetic barrier. When the magnetic field is adjusted so that (rho/sub i/rho/sub e/)/sup 1/2/ very-much-less-than a < rho/sub i/, a virtual anode is formed whose potential oscillates at approx.ω/sub p/i about a value near the ion accelerating potential, where a is the transverse beam dimension, ω/sub tsp/i is the ion plasma frequency, and rho/sub e/ and rho/sub i/ are the electron and ion gyroradii. This behavior is similar to that predicted by Poukey and Rostoker for virtual cathodes

  5. Theoretical investigation of intensity-dependent optical nonlinearity in graphene-aided D-microfiber

    Science.gov (United States)

    Shah, Manoj Kumar; Lu, Rongguo; Zhang, Yali; Ye, Shengwei; Zhang, Shangjian; Liu, Yong

    2018-01-01

    We theoretically investigate the intensity-dependent optical nonlinearity in graphene-aided D-microfiber, by tuning the chemical potential of graphene and varying radial distance and radii of the D-microfiber. Utilizing an interplay between graphene and the enhanced evanescent field of a guided mode in the waveguide of interest, the net utility of nonlinear coefficient is harnessed up to a very high value of 106 W-1m-1. Importantly, which is ∼ two orders of magnitude larger than in PMMA-graphene-PMMA waveguide. The highly dispersive nature of the waveguide, D ∼ 103 ps/nm-km, and large nonlinear figure-of-merit, FOMNL ∼ 1.29, have raised the possibilities of utilizing slow light structures to operate devices at few watts power level with microscale length. These studies have opened one window towards the next-generation all fiber-optic graphene nonlinear optical devices.

  6. Single-intensity-recording optical encryption technique based on phase retrieval algorithm and QR code

    Science.gov (United States)

    Wang, Zhi-peng; Zhang, Shuai; Liu, Hong-zhao; Qin, Yi

    2014-12-01

    Based on phase retrieval algorithm and QR code, a new optical encryption technology that only needs to record one intensity distribution is proposed. In this encryption process, firstly, the QR code is generated from the information to be encrypted; and then the generated QR code is placed in the input plane of 4-f system to have a double random phase encryption. For only one intensity distribution in the output plane is recorded as the ciphertext, the encryption process is greatly simplified. In the decryption process, the corresponding QR code is retrieved using phase retrieval algorithm. A priori information about QR code is used as support constraint in the input plane, which helps solve the stagnation problem. The original information can be recovered without distortion by scanning the QR code. The encryption process can be implemented either optically or digitally, and the decryption process uses digital method. In addition, the security of the proposed optical encryption technology is analyzed. Theoretical analysis and computer simulations show that this optical encryption system is invulnerable to various attacks, and suitable for harsh transmission conditions.

  7. Optical fibres sensor based in the intensity switch of a linear laser with two Bragg gratings

    International Nuclear Information System (INIS)

    Basurto P, M.A.; Kuzin, E.A.; Archundia B, C.; Marroquin, E.; May A, M.; Cerecedo N, H.H.; Sanchez M, J.J.; Tentori S, D.; Marquez B, I.; Shliagin, M.; Miridonov, S.

    2000-01-01

    In this work we propose a new configuration for an optical fiber temperature sensor, based on a linear type Er-doped fiber laser. The laser cavity consists of an Er-doped fiber and two identical Bragg gratings at the fiber ends (working as reflectors). Temperature changes are detected by measuring, through one of the gratings, the intensity variations at the system's output. When the temperature of one of the Bragg gratings is modified, a wavelength shift of its spectral reflectivity is observed. Hence, the laser emission intensity of the system is modified. We present experimental results of the intensity switch observed when the temperature difference between the gratings detunes their spectral reflectance. Making use of this effect it is possible to develop limit comparators to bound the temperature range for the object under supervision. This limiting work can be performed with a high sensitivity using a very simple interrogation procedure. (Author)

  8. Incidence of Candida species colonization in neonatal intensive care unit at Riyadh Hospital, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Mohammed S. Alhussaini

    2016-10-01

    Full Text Available Background: Candida species are important hospital-acquired pathogens in infants admitted to the neonatal intensive care unit (NICU. This study was performed in the NICU of Saudi Arabian Hospital, Riyadh region, KSA to analyze patterns of neonatal Candida colonization as well as to determine the potential risk factors.Methods: Weekly surveillance fungal cultures of anal area, oral cavity, umbilicus and ear canal of neonates were performed from birth until their discharge from the hospital. Colonization was analyzed for timing, site, species, birth weight and gestational age. Potential environmental reservoirs and hands of health care workers (HCWs were also cultured monthly for fungi. Antifungal susceptibility of the identified isolates was also determined.Results: One hundred subjects have been recruited in this study. The overall colonization rate was 51%. Early colonization was found in 27 (27% neonates whereas 24 (24% neonates were lately colonized during their stay in NICU. Colonization was more in preterm neonates than in full and post term. Perianal area and oral cavity were the most frequent colonized sites. C. albicans was the main spp. (58.8% isolated from the neonates followed by C. tropicalis (17.6%, C. glabrata (15.6%, and C. krusei (2%. Of the 51 isolated Candida spp., 68.6% were sensitive to fluconazole, 80% to itraconazole and 64.7% to ketoconazole, while only 33% were sensitive to amphotericin B.Conclusion: Candida has emerged as a common cause of infections in infants admitted to NICU, and C. albicans is the most commonly isolated candidal species. Neonatal infections caused by non- albicans species occur at a later age during their stay in NICU.

  9. Diarréia nosocomial em unidade de terapia intensiva: incidência e fatores de risco Nosocomial diarrhea in the intensive care unit: incidence and risk factors

    Directory of Open Access Journals (Sweden)

    Sérvulo Luiz Borges

    2008-06-01

    Full Text Available RACIONAL: Diarréia nosocomial parece ser comum em unidades de terapia intensiva, embora sua epidemiologia seja pouco documentada em nosso meio. OBJETIVO: Determinar a incidência e fatores de risco de diarréia entre pacientes adultos internados em unidade de terapia intensiva. MÉTODOS: Foram incluídos prospectivamente 457 pacientes no período entre outubro de 2005 e outubro de 2006. Dados demográficos, clínicos e bioquímicos, bem como aspecto e número de evacuações eram registrados diariamente até a saída do paciente do setor. RESULTADOS: Diarréia ocorreu em 135 (29,5% pacientes, durando em média 5,4 dias. O tempo do seu início em relação à internação foi de 17,8 dias e casos similares de diarréia no mesmo período foram registrados em 113 (83,7% pacientes. A mortalidade hospitalar foi maior nos pacientes com diarréia do que naqueles sem esta intercorrência. Na análise multivariada através de modelo de regressão logística, apenas o número de antibióticos (OR 1,65; IC 95% = 1,39-1,95 e o número de dias de antibioticoterapia (OR 1,16; IC 95% = 1,12-1,20 associaram-se estatisticamente com a ocorrência de diarréia. Cada dia de acréscimo a mais da antibioticoterapia aumentou em 16% o risco de diarréia (IC 12% a 20%, enquanto a adição de um antibiótico a mais ao esquema antimicrobiano aumentou as chances de ocorrência de diarréia em 65% (IC 39% a 95%. CONCLUSÃO: A incidência de diarréia nosocomial na unidade de terapia intensiva é elevada (29,5%. Os principais fatores de risco para sua ocorrência foram número de antibióticos prescritos e duração da antibioticoterapia. Além das precauções entéricas, a prescrição judiciosa e limitada de antimicrobianos, provavelmente reduzirá a ocorrência de diarréia neste setor.BACKGROUND: Nosocomial diarrhea seems to be common at intensive care units, although its epidemiology be poorly documented in Brazil. AIM: To determine the incidence and risk factors of

  10. Adaptive grazing incidence optics for the next generation of x-ray observatories

    Science.gov (United States)

    Lillie, C.; Pearson, D.; Plinta, A.; Metro, B.; Lintz, E.; Shropshire, D.; Danner, R.

    2010-09-01

    Advances in X-ray astronomy require high spatial resolution and large collecting area. Unfortunately, X-ray telescopes with grazing incidence mirrors require hundreds of concentric mirror pairs to obtain the necessary collecting area, and these mirrors must be thin shells packed tightly together... They must also be light enough to be placed in orbit with existing launch vehicles, and able to be fabricated by the thousands for an affordable cost. The current state of the art in X-ray observatories is represented by NASA's Chandra X-ray observatory with 0.5 arc-second resolution, but only 400 cm2 of collecting area, and by ESA's XMM-Newton observatory with 4,300 cm2 of collecting area but only 15 arc-second resolution. The joint NASA/ESA/JAXA International X-ray Observatory (IXO), with {15,000 cm2 of collecting area and 5 arc-second resolution which is currently in the early study phase, is pushing the limits of passive mirror technology. The Generation-X mission is one of the Advanced Strategic Mission Concepts that NASA is considering for development in the post-2020 period. As currently conceived, Gen-X would be a follow-on to IXO with a collecting area >= 50 m2, a 60-m focal length and 0.1 arc-second spatial resolution. Gen-X would be launched in {2030 with a heavy lift Launch Vehicle to an L2 orbit. Active figure control will be necessary to meet the challenging requirements of the Gen-X optics. In this paper we present our adaptive grazing incidence mirror design and the results from laboratory tests of a prototype mirror.

  11. Multiple time scales in modeling the incidence of infections acquired in intensive care units

    Directory of Open Access Journals (Sweden)

    Martin Wolkewitz

    2016-09-01

    Full Text Available Abstract Background When patients are admitted to an intensive care unit (ICU their risk of getting an infection will be highly depend on the length of stay at-risk in the ICU. In addition, risk of infection is likely to vary over calendar time as a result of fluctuations in the prevalence of the pathogen on the ward. Hence risk of infection is expected to depend on two time scales (time in ICU and calendar time as well as competing events (discharge or death and their spatial location. The purpose of this paper is to develop and apply appropriate statistical models for the risk of ICU-acquired infection accounting for multiple time scales, competing risks and the spatial clustering of the data. Methods A multi-center data base from a Spanish surveillance network was used to study the occurrence of an infection due to Methicillin-resistant Staphylococcus aureus (MRSA. The analysis included 84,843 patient admissions between January 2006 and December 2011 from 81 ICUs. Stratified Cox models were used to study multiple time scales while accounting for spatial clustering of the data (patients within ICUs and for death or discharge as competing events for MRSA infection. Results Both time scales, time in ICU and calendar time, are highly associated with the MRSA hazard rate and cumulative risk. When using only one basic time scale, the interpretation and magnitude of several patient-individual risk factors differed. Risk factors concerning the severity of illness were more pronounced when using only calendar time. These differences disappeared when using both time scales simultaneously. Conclusions The time-dependent dynamics of infections is complex and should be studied with models allowing for multiple time scales. For patient individual risk-factors we recommend stratified Cox regression models for competing events with ICU time as the basic time scale and calendar time as a covariate. The inclusion of calendar time and stratification by ICU

  12. Perianal Dermatitis, Its Incidence, and Patterns of Topical Therapies in a Level IV Neonatal Intensive Care Unit.

    Science.gov (United States)

    Malik, Anuj; Witsberger, Emily; Cottrell, Lesley; Kiefer, Autumn; Yossuck, Panitan

    2018-04-01

     To define the incidence of perianal dermatitis (PD) and determine the usage pattern and cost efficacy of diaper products among neonates admitted to a level IV neonatal intensive care unit (NICU) including those with a diagnosis of neonatal abstinence syndrome (NAS).  A retrospective cohort study to evaluate neonates with PD based on number of orders for Aquaphor, Bagbalm, Desitin, Flanders, or Nystatin. Various demographic and clinical parameters were recorded. Usage patterns of these five products were analyzed, and their costs estimated. Subgroup analysis was performed among infants with NAS.  Of 1,241 admissions, 56.2% had at least one diaper product ordered during their NICU stay, while 52.6% had multiple products ordered. Only 23.0% of all neonates had appropriate documentation of PD. The most common product ordered first was Aquaphor (64.3%), followed by Desitin (19.2%). Note that 86% term NAS infants had PD compared with 28% term non-NAS infants. The estimated product cost was $14,139 over 2 years, averaging $20 per patient.  Over half of NICU neonates were exposed to one or more diaper products, usually without documented PD diagnosis. Term NAS infants had three times higher incidence of PD than term non-NAS infants. The cost of diaper product use was significant, and possibly underestimated due to lack of documentation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Incidence, microbiological profile of nosocomial infections, and their antibiotic resistance patterns in a high volume Cardiac Surgical Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Sahu

    2016-01-01

    Full Text Available Background: Nosocomial infections (NIs in the postoperative period not only increase morbidity and mortality, but also impose a significant economic burden on the health care infrastructure. This retrospective study was undertaken to (a evaluate the incidence, characteristics, risk factors and outcomes of NIs and (b identify common microorganisms responsible for infection and their antibiotic resistance profile in our Cardiac Surgical Intensive Care Unit (CSICU. Patients and Methods: After ethics committee approval, the CSICU records of all patients who underwent cardiovascular surgery between January 2013 and December 2014 were reviewed retrospectively. The incidence of NI, distribution of NI sites, types of microorganisms and their antibiotic resistance, length of CSICU stay, and patient-outcome were determined. Results: Three hundred and nineteen of 6864 patients (4.6% developed NI after cardiac surgery. Lower respiratory tract infections (LRTIs accounted for most of the infections (44.2% followed by surgical-site infection (SSI, 11.6%, bloodstream infection (BSI, 7.5%, urinary tract infection (UTI, 6.9% and infections from combined sources (29.8%. Acinetobacter, Klebsiella, Escherichia coli, and Staphylococcus were the most frequent pathogens isolated in patients with LRTI, BSI, UTI, and SSI, respectively. The Gram-negative bacteria isolated from different sources were found to be highly resistant to commonly used antibiotics. Conclusion: The incidence of NI and sepsis-related mortality, in our CSICU, was 4.6% and 1.9%, respectively. Lower respiratory tract was the most common site of infection and Gram-negative bacilli, the most common pathogens after cardiac surgery. Antibiotic resistance was maximum with Acinetobacter spp.

  14. Micromachined diffraction based optical microphones and intensity probes with electrostatic force feedback

    Science.gov (United States)

    Bicen, Baris

    Measuring acoustic pressure gradients is critical in many applications such as directional microphones for hearing aids and sound intensity probes. This measurement is especially challenging with decreasing microphone size, which reduces the sensitivity due to small spacing between the pressure ports. Novel, micromachined biomimetic microphone diaphragms are shown to provide high sensitivity to pressure gradients on one side of the diaphragm with low thermal mechanical noise. These structures have a dominant mode shape with see-saw like motion in the audio band, responding to pressure gradients as well as spurious higher order modes sensitive to pressure. In this dissertation, integration of a diffraction based optical detection method with these novel diaphragm structures to implement a low noise optical pressure gradient microphone is described and experimental characterization results are presented, showing 36 dBA noise level with 1mm port spacing, nearly an order of magnitude better than the current gradient microphones. The optical detection scheme also provides electrostatic actuation capability from both sides of the diaphragm separately which can be used for active force feedback. A 4-port electromechanical equivalent circuit model of this microphone with optical readout is developed to predict the overall response of the device to different acoustic and electrostatic excitations. The model includes the damping due to complex motion of air around the microphone diaphragm, and it calculates the detected optical signal on each side of the diaphragm as a combination of two separate dominant vibration modes. This equivalent circuit model is verified by experiments and used to predict the microphone response with different force feedback schemes. Single sided force feedback is used for active damping to improve the linearity and the frequency response of the microphone. Furthermore, it is shown that using two sided force feedback one can significantly suppress

  15. AN EVOLUTIONARY ALGORITHM FOR FAST INTENSITY BASED IMAGE MATCHING BETWEEN OPTICAL AND SAR SATELLITE IMAGERY

    Directory of Open Access Journals (Sweden)

    P. Fischer

    2018-04-01

    Full Text Available This paper presents a hybrid evolutionary algorithm for fast intensity based matching between satellite imagery from SAR and very high-resolution (VHR optical sensor systems. The precise and accurate co-registration of image time series and images of different sensors is a key task in multi-sensor image processing scenarios. The necessary preprocessing step of image matching and tie-point detection is divided into a search problem and a similarity measurement. Within this paper we evaluate the use of an evolutionary search strategy for establishing the spatial correspondence between satellite imagery of optical and radar sensors. The aim of the proposed algorithm is to decrease the computational costs during the search process by formulating the search as an optimization problem. Based upon the canonical evolutionary algorithm, the proposed algorithm is adapted for SAR/optical imagery intensity based matching. Extensions are drawn using techniques like hybridization (e.g. local search and others to lower the number of objective function calls and refine the result. The algorithm significantely decreases the computational costs whilst finding the optimal solution in a reliable way.

  16. Optical gain for the interband optical transition in InAsP/InP quantum well wire in the influence of laser field intensity

    Energy Technology Data Exchange (ETDEWEB)

    Saravanan, S. [Dept.of Physics, GTN Arts College, Dindigul-624 005. India (India); Peter, A. John, E-mail: a.john.peter@gmail.com [P.G & Research Dept.of Physics, Government Arts College, Melur-625 106. Madurai. India (India)

    2016-05-23

    Intense high frequency laser field induced electronic and optical properties of heavy hole exciton in the InAs{sub 0.8}P{sub 0.2}/InP quantum wire is studied taking into account the geometrical confinement effect. Laser field related exciton binding energies and the optical band gap in the InAs{sub 0.8}P{sub 0.2}/InP quantum well wire are investigated. The optical gain, for the interband optical transition, as a function of photon energy, in the InAs{sub 0.8}P{sub 0.2}/InP quantum wire, is obtained in the presence of intense laser field. The compact density matrix method is employed to obtain the optical gain. The obtained optical gain in group III-V narrow quantum wire can be applied for achieving the preferred telecommunication wavelength.

  17. Optical Spectroscopy Measurements of Shock Waves Driven by Intense Z-Pinch Radiation

    International Nuclear Information System (INIS)

    Asay, J.; Bernard, M.; Bailey, J.E.; Carlson, A.L.; Chandler, G.A.; Hall, C.A.; Hanson, D.; Johnston, R.; Lake, P.; Lawrence, J.

    1999-01-01

    Z-pinches created using the Z accelerator generate approximately220 TW, 1.7 MJ radiation pulses that heat large (approximately10 cm 3 ) hohlraums to 100-150 eV temperatures for times of order 10 nsec. We are performing experiments exploiting this intense radiation to drive shock waves for equation of state studies. The shock pressures are typically 1-10 Mbar with 10 nsec duration in 6-mm-diameter samples. In this paper we demonstrate the ability to perform optical spectroscopy measurements on shocked samples located in close proximity to the z-pinch. These experiments are particularly well suited to optical spectroscopy measurements because of the relatively large sample size and long duration. The optical emission is collected using fiber optics and recorded with a streaked spectrograph. Other diagnostics include VISAR and active shock breakout measurements of the shocked sample and a suite of diagnostics that characterize the radiation drive. Our near term goal is to use the spectral emission to obtain the temperature of the shocked material. Longer term objectives include the examination of deviations of the spectrum from blackbody, line emission from lower density regions, determination of kinetic processes in molecular systems, evaluation of phase transitions such as the onset of metalization in transparent materials, and characterization of the plasma formed when the shock exits the rear surface. An initial set of data illustrating both the potential and the challenge of these measurements is described

  18. System and method that suppresses intensity fluctuations for free space high-speed optical communication

    Science.gov (United States)

    Berman, Gennady P [Los Alamos, NM; Bishop, Alan R [Los Alamos, NM; Nguyen, Dinh C [Los Alamos, NM; Chernobrod, Boris M [Santa Fe, NM; Gorshkov, Vacheslav N [Kiev, UA

    2009-10-13

    A high-speed (Gbps), free space optical communication system is based on spectral encoding of radiation from a wide band light source, such as a laser. By using partially coherent laser beams in combination with a relatively slow photosensor, scintillations can be suppressed by orders of magnitude for distances of more than 10 km. To suppress the intensity fluctuations due to atmospheric turbulence, a source with partial transverse coherence in combination with slow response time photodetector is used. Information is encoded in the spectral domain of a wideband optical source by modulation of spectral amplitudes. A non-coherent light source with wide spectrum (an LED, for example) may be used for high-speed communication over short (less than about a mile) distances.

  19. Practical implementation of spectral-intensity dispersion-canceled optical coherence tomography with artifact suppression

    Science.gov (United States)

    Shirai, Tomohiro; Friberg, Ari T.

    2018-04-01

    Dispersion-canceled optical coherence tomography (OCT) based on spectral intensity interferometry was devised as a classical counterpart of quantum OCT to enhance the basic performance of conventional OCT. In this paper, we demonstrate experimentally that an alternative method of realizing this kind of OCT by means of two optical fiber couplers and a single spectrometer is a more practical and reliable option than the existing methods proposed previously. Furthermore, we develop a recipe for reducing multiple artifacts simultaneously on the basis of simple averaging and verify experimentally that it works successfully in the sense that all the artifacts are mitigated effectively and only the true signals carrying structural information about the sample survive.

  20. Optical Frequency Optimization of a High Intensity Laser Power Beaming System Utilizing VMJ Photovoltaic Cells

    Science.gov (United States)

    Raible, Daniel E.; Dinca, Dragos; Nayfeh, Taysir H.

    2012-01-01

    An effective form of wireless power transmission (WPT) has been developed to enable extended mission durations, increased coverage and added capabilities for both space and terrestrial applications that may benefit from optically delivered electrical energy. The high intensity laser power beaming (HILPB) system enables long range optical 'refueling" of electric platforms such as micro unmanned aerial vehicles (MUAV), airships, robotic exploration missions and spacecraft platforms. To further advance the HILPB technology, the focus of this investigation is to determine the optimal laser wavelength to be used with the HILPB receiver, which utilizes vertical multi-junction (VMJ) photovoltaic cells. Frequency optimization of the laser system is necessary in order to maximize the conversion efficiency at continuous high intensities, and thus increase the delivered power density of the HILPB system. Initial spectral characterizations of the device performed at the NASA Glenn Research Center (GRC) indicate the approximate range of peak optical-to-electrical conversion efficiencies, but these data sets represent transient conditions under lower levels of illumination. Extending these results to high levels of steady state illumination, with attention given to the compatibility of available commercial off-the-shelf semiconductor laser sources and atmospheric transmission constraints is the primary focus of this paper. Experimental hardware results utilizing high power continuous wave (CW) semiconductor lasers at four different operational frequencies near the indicated band gap of the photovoltaic VMJ cells are presented and discussed. In addition, the highest receiver power density achieved to date is demonstrated using a single photovoltaic VMJ cell, which provided an exceptionally high electrical output of 13.6 W/sq cm at an optical-to-electrical conversion efficiency of 24 percent. These results are very promising and scalable, as a potential 1.0 sq m HILPB receiver of

  1. Intense coherent longitudinal optical phonons in CuI thin films under exciton-excitation conditions

    International Nuclear Information System (INIS)

    Kojima, O.; Mizoguchi, K.; Nakayama, M..

    2005-01-01

    We have investigated the dynamical properties of the coherent longitudinal optical (LO) phonon in CuI thin films grown on a NaCl substrate by vacuum deposition. The intense coherent LO phonon in the CuI thin film is observed under the exciton-excitation conditions. Moreover, the pump-energy dependence of the amplitude of the coherent LO phonon shows peaks at the heavy-hole and light-hole exciton energies. The enhancement of the coherent LO phonon under the exciton-resonance condition is much larger than that in an ordinary semiconductor quantum well system such as a GaAs/AlAs one. These facts demonstrate that the intense coherent LO phonon is generated under the exciton-excitation condition in a material with a strong exciton-phonon interaction such as CuI

  2. Study of intense pulse irradiation effects on silicon targets considered as ground matter for optical detectors

    International Nuclear Information System (INIS)

    Muller, O.

    1994-12-01

    This study aim was centered on morphological and structural alterations induced by laser irradiation on silicon targets considered as ground matter for optical detectors. First we recalled the main high light intensity effects on the condensed matter. Then we presented the experimental aspects. The experimental studies were achieved on two sample types: SiO 2 /Si and Si. Two topics were studied: the defect chronology according to wavelength and pulse length, and the crystalline quality as well as the structure defects of irradiated zones by Raman spectroscopy. Finally, irradiation of Si targets by intense pulsed beams may lead to material fusion. This phenomenon is particularly easy when the material is absorbent, when the pulse is short and when the material is superficially oxidized. (MML). 204 refs., 93 figs., 21 tabs., 1 appendix

  3. Differential standard deviation of log-scale intensity based optical coherence tomography angiography.

    Science.gov (United States)

    Shi, Weisong; Gao, Wanrong; Chen, Chaoliang; Yang, Victor X D

    2017-12-01

    In this paper, a differential standard deviation of log-scale intensity (DSDLI) based optical coherence tomography angiography (OCTA) is presented for calculating microvascular images of human skin. The DSDLI algorithm calculates the variance in difference images of two consecutive log-scale intensity based structural images from the same position along depth direction to contrast blood flow. The en face microvascular images were then generated by calculating the standard deviation of the differential log-scale intensities within the specific depth range, resulting in an improvement in spatial resolution and SNR in microvascular images compared to speckle variance OCT and power intensity differential method. The performance of DSDLI was testified by both phantom and in vivo experiments. In in vivo experiments, a self-adaptive sub-pixel image registration algorithm was performed to remove the bulk motion noise, where 2D Fourier transform was utilized to generate new images with spatial interval equal to half of the distance between two pixels in both fast-scanning and depth directions. The SNRs of signals of flowing particles are improved by 7.3 dB and 6.8 dB on average in phantom and in vivo experiments, respectively, while the average spatial resolution of images of in vivo blood vessels is increased by 21%. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Incidence and Risk Factors for Intensive Care Unit–related Post-traumatic Stress Disorder in Veterans and Civilians

    Science.gov (United States)

    Jackson, James C.; Morandi, Alessandro; Girard, Timothy D.; Hughes, Christopher G.; Thompson, Jennifer L.; Kiehl, Amy L.; Elstad, Mark R.; Wasserstein, Mitzi L.; Goodman, Richard B.; Beckham, Jean C.; Chandrasekhar, Rameela; Dittus, Robert S.; Ely, E. Wesley; Pandharipande, Pratik P.

    2016-01-01

    Rationale: The incidence and risk factors of post-traumatic stress disorder (PTSD) related to the intensive care unit (ICU) experience have not been reported in a mixed veteran and civilian cohort. Objectives: To describe the incidence and risk factors for ICU-related PTSD in veterans and civilians. Methods: This is a prospective, observational, multicenter cohort enrolling adult survivors of critical illness after respiratory failure and/or shock from three Veterans Affairs and one civilian hospital. After classifying those with/without preexisting PTSD (i.e., PTSD before hospitalization), we then assessed all subjects for ICU-related PTSD at 3 and 12 months post hospitalization. Measurements and Main Results: Of 255 survivors, 181 and 160 subjects were assessed for ICU-related PTSD at 3- and 12-month follow-up, respectively. A high probability of ICU-related PTSD was found in up to 10% of patients at either follow-up time point, whether assessed by PTSD Checklist Event-Specific Version (score ≥ 50) or item mapping using the Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV). In the multivariable regression, preexisting PTSD was independently associated with ICU-related PTSD at both 3 and 12 months (P < 0.001), as was preexisting depression (P < 0.03), but veteran status was not a consistent independent risk factor for ICU-related PTSD (3-month P = 0.01, 12-month P = 0.48). Conclusions: This study found around 1 in 10 ICU survivors experienced ICU-related PTSD (i.e., PTSD anchored to their critical illness) in the year after hospitalization. Preexisting PTSD and depression were strongly associated with ICU-related PTSD. PMID:26735627

  5. Incidence of the acute renal failure in the intensive care unit at the General Hospital of Mexico: Risk factors and associated morbidity and mortality

    OpenAIRE

    Herrera-Méndez, J.; Sánchez-Velázquez, L.D.; González-Chávez, A.; Rodríguez-Terán, G.

    2015-01-01

    Background: The acute renal failure (ARF) contributes to a longer hospital stay, morbidity, mortality and use of resources in critical patients. The estimate of its incidence was difficult, mainly due to the lack of a generally accepted definition. Objective: To determine the incidence, risk factors and effects of the ARF in critical patients. Material and methods: Study of prospective cohort. Patients hospitalised in the Intensive Care Unit (ICU) were included. The population was di...

  6. Adjustable Grazing Incidence X-ray Optics with 0.5 Arc Second Resolution

    Science.gov (United States)

    Reid, Paul

    We seek to develop adjustable grazing incidence optics for x-ray astronomy. The goal of this development is thin, lightweight mirrors with angular resolution of 0.5 arc seconds, comparable to the Chandra X-ray Observatory. The new mirror design consists of thin segments of a Wolter-I grazing incidence mirror, with piezo-electric material deposited directly on the back surface of the mirror. Depositing a pattern of independently addressable electrodes on top of the piezoelectric material produces an array of independent piezo cells. Energizing a particular cell introduces a localized deformation in the mirror without the need for a reaction structure. By applying the appropriate voltage to the piezo cells, it is possible to correct mirror figure errors that result from mirror fabrication, gravity release, mounting, and thermal effects. Because the thin mirrors segments are lightweight, they can be densely nested to produce collecting area thirty times that of Chandra, on an affordably priced mission. This Supporting Technology program is a follow-on to an existing APRA program. In the existing program we demonstrated the first successful deposition of piezoelectric material on thermally formed glass substrates. We showed that the localized deformations produced by the piezo cells match finite element predictions, and the piezo cell adjustment range meets requirements necessary to achieve the desired figure correction. We have also shown through simulation that representative mirror figure errors can be corrected via modeled influence functions to achieve 0.5 arc sec imaging performance. This provides a firm foundation on which to develop further the technology. We will continue to optimize the deposition of thin piezoelectric films onto thermally formed glass and electroplated metal mirror segments to improve yield and manufacturability. We will deposit piezoelectric material onto conical mirror segments and demonstrate figure correction in agreement with prediction

  7. The influence of age, breed, rearing intensity and exercise on the incidence of spavin in Swedish dairy cattle: a clinical and morphological investigation

    International Nuclear Information System (INIS)

    Holmberg, T.; Reiland, S.

    1984-01-01

    The hocks of tied cows of a Swedish dairy herd of different breeds were radiographed. Osteoarthrosis of the arthrodial joints (spavin) was found in 37% of the animals. Changes were seen before the cows were 2 yr old, and they increased in severity with increasing age. Macroscopic and histologic examination revealed that there was osteoarthrosis also in many radiologically normal hocks. The frequency of spavin in tied dairy cows is higher than clinical signs indicate. Only cows with fusion of the arthrodial joints show the stiff hind leg movements considered typical of spavin. Differences in the incidence of spavin were found between the different breeds. Cows of the Swedish Friesian breed had the lowest (20%) and cows of the Jersey breed had the highest (50%) incidence of spavin. As regards the Jersey breed this was due to the high incidence (71%) found in cows raised on a high intensity feeding during the young stock period. Among the SJB [Swedish Jersey] cows raised on a normal intensity feeding the incidence of spavin was 25%. Such a relationship between high young stock feeding intensity and the incidence of spavin was not seen within the other breeds. The cows in another herd with loose housing had a lower frequency of spavin than the tied cows. Offspring of animals with spavin had a higher incidence of spavin than the offspring of animals without spavin. (author)

  8. The influence of age, breed, rearing intensity and exercise on the incidence of spavin in Swedish dairy cattle: a clinical and morphological investigation

    Energy Technology Data Exchange (ETDEWEB)

    Holmberg, T.; Reiland, S. [Sveriges Lantbruksuniversitet, Uppsala (Sweden)

    1984-07-01

    The hocks of tied cows of a Swedish dairy herd of different breeds were radiographed. Osteoarthrosis of the arthrodial joints (spavin) was found in 37% of the animals. Changes were seen before the cows were 2 yr old, and they increased in severity with increasing age. Macroscopic and histologic examination revealed that there was osteoarthrosis also in many radiologically normal hocks. The frequency of spavin in tied dairy cows is higher than clinical signs indicate. Only cows with fusion of the arthrodial joints show the stiff hind leg movements considered typical of spavin. Differences in the incidence of spavin were found between the different breeds. Cows of the Swedish Friesian breed had the lowest (20%) and cows of the Jersey breed had the highest (50%) incidence of spavin. As regards the Jersey breed this was due to the high incidence (71%) found in cows raised on a high intensity feeding during the young stock period. Among the SJB [Swedish Jersey] cows raised on a normal intensity feeding the incidence of spavin was 25%. Such a relationship between high young stock feeding intensity and the incidence of spavin was not seen within the other breeds. The cows in another herd with loose housing had a lower frequency of spavin than the tied cows. Offspring of animals with spavin had a higher incidence of spavin than the offspring of animals without spavin. (author)

  9. Temperature-dependent of Nonlinear Optical Conductance of Graphene-based Systems in High-intensity Terahertz Field

    Institute of Scientific and Technical Information of China (English)

    Jing Lv; Rui-yang Yuan; Hui Yan

    2014-01-01

    For multi-photon processed with the linear dispersion in the high-intensity terahertz(THz) field,we have systematically investigated the temperature-dependent nonlinear optical response of graphene-based systems, including single layer graphene, graphene superlattice and gapped graphene. In the intrinsic single layer graphene system, it demonstrates that, at low temperature, nonlinear optical conductivities of the thirdand fifth-order are respectively five and ten orders of magnitude larger than the universal conductivity with high-intensity and low frequency THz wave.In the graphene superlattice and gapped graphene systems, the optical responses enhanced because of the anisotropic massless and massive Dirac fermions.

  10. Temp erature-dep endent of Nonlinear Optical Conductance of Graphene-based Systems in High-intensity Terahertz Field

    Institute of Scientific and Technical Information of China (English)

    Jing Lv; Rui-yang Yuan; Hui Yan

    2014-01-01

    For multi-photon processed with the linear dispersion in the high-intensity terahertz (THz) field, we have systematically investigated the temperature-dependent nonlinear optical response of graphene-based systems, including single layer graphene, graphene superlattice and gapped graphene. In the intrinsic single layer graphene system, it demonstrates that, at low temperature, nonlinear optical conductivities of the third-and fifth-order are respectively five and ten orders of magnitude larger than the universal conductivity with high-intensity and low frequency THz wave.In the graphene superlattice and gapped graphene systems, the optical responses enhanced because of the anisotropic massless and massive Dirac fermions.

  11. Type IIA photosensitivity and formation of pores in optical fibers under intense ultraviolet irradiation

    International Nuclear Information System (INIS)

    Kukushkin, S. A.; Shlyagin, M. G.; Swart, P. L.; Chtcherbakov, A. A.; Osipov, A. V.

    2007-01-01

    Formation of the type IIA Bragg gratings in germanosilicate optical fibers is studied. We report the observation of such a type of gratings in the standard single-mode fiber (Corning SMF-28) under different experimental conditions. A mechanism for the type IIA photosensitivity in optical fibers is proposed which is based on nucleation and evolution of pores from vacancy-type defects in fiber areas where a high level of mechanical stress is induced under intense ultraviolet (UV) light. Evolution of fiber core temperature under influence of a single 20 ns light pulse from a KrF excimer laser was measured and compared with theoretical calculations. It was shown that transient thermoinduced stress in the fiber core can achieve a level sufficient for effective nucleation of pores. A theory describing formation of pores in optical fibers has been developed and was used to estimate the pore nucleation rate, concentration, and other parameters of pore evolution for different levels of UV fluence and fiber core stress

  12. Distribution measurement of radiation intensity with optical fiber at narrow space

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Chizuo [Nagoya Univ. (Japan). School of Engineering

    1998-07-01

    Recently, in the field or radiation measurement, optical fiber and scintillation fiber are also begun to use. In order to investigate a new application method of the optical fiber to radiation measurement, a lithium compound for neutron converter and a ZnS(Ag) scintillator are kneaded with epoxy type adhesives, and much few weight of them is coated at an end of optical fiber with 1 to 2 mm in diameter, which is further overcoated with black paint or an aluminum cap for its shielding light to produce a thermal neutron detector. The thermal neutron detector is found to be measurable to neutron flux distribution very rapidly and in high position resolution by moving with computer automatically. This method can be measured selctively aimed radiation such as thermal neutron, rapid neutron, {gamma}-ray, and so forth by means of changing the neutron converter. And, the developed fiber method could be widely used for measurement of neutron and {gamma}-ray intensity distribution at fine interval in the nuclear radiation facilities such as neighbors of accelerator facilities, medical radiation facilities. (G.K.)

  13. Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry

    Science.gov (United States)

    Dekker, Kurtis H.; Hazarika, Rubin; Silveira, Matheus A.; Jordan, Kevin J.

    2018-03-01

    Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large (⩾10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5–10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%–20% of the camera sensor’s range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes (∼15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.

  14. Synchronization trigger for HSFC in the optical diagnosis of intense electron beam cathodes

    International Nuclear Information System (INIS)

    Yang Jie; Shu Ting; Zhang Jun; Yang Jianhua; Liu Lie; Yin Yi; Luo Ling

    2010-01-01

    This paper presents an intense electron beam cathodes optical diagnosis platform, which consists of an accelerator using a water-dielectric helical pulse forming line (PFL) and a high speed framing camera (HSFC-PRO) with an minimum exposure of 3 ns. HSFC-PRO must work synchronously with the explosive process of the intense electron beam cathodes in order to obtain correct data. On one hand, the high voltage electrical pulse from the PFL is delayed by a water-dielectric helix line with a nearly 110ns electrical length. On the other hand, The synchronization trigger signal for the HSFC-PRO is obtained from the pre d elayed high voltage electrical pulse from the PFL. A TTL signal (5 V) with rising edge is required to trigger the HSFC. The rise time (10% to 90%) should be <20ns. As a result, the negative-edge attenuated electrical pulse with a about 25 ns rise time from the PFL can not trigger the HSFC immediately.Consequently, the polarity of the attenuated high voltage electrical pulse from the PFL is reversed by a pulse transformer. Then it is converted subsequently into a TTL signal (5 V) with rising edge via a monostable multivibrator , The rise time (10% to 90%) is <5 ns, which is suitable for HSFC absequently. This established optical diagnosis platform can supply an electrical pulse with its output voltage of 200-400 kV, risetime of ∼35ns and pulse width(FWHM) of ∼110ns. By means of delaying the electrical pulse, the synchronization trigger problem of the HSFC-PRO has been solved properly, with correlative time precision of about ns level, which sets a running start for the following intensive research of explosive emission cathodes. (authors)

  15. Effect of Intensive Education and Training of Nurses on Ventilator-associated Pneumonia and Central Line-associated Bloodstream Infection Incidence in Intensive Care Unit at a Tertiary Care Center in North India.

    Science.gov (United States)

    Sahni, Neeru; Biswal, Manisha; Gandhi, Komal; Kaur, Kulbeer; Saini, Vikas; Yaddanapudi, Lakshminarayana N

    2017-11-01

    The aim was to analyze the impact of education and training of nurses on the incidence of ventilator-associated pneumonia (VAP) and central line-associated bloodstream infection (CLABSI). A prospective observational study at a tertiary care hospital included adult patients with Intensive Care Unit stay >48 h. The study was done in three phases: in Phase 1, baseline VAP and CLABSI incidence was calculated; in Phase 2, education and training of nurses; and in Phase 3, data were recollected for the incidence of VAP and CLABSI. The baseline incidence of VAP in Phase 1 was 28.86/1000 ventilator days and that of CLABSI was 7.89/1000 central-line days. In Phase 3, the incidence of VAP increased to 35.06 and that of CLABSI decreased significantly, 1.73. Intensive education and training sessions with feedback from nurses over a period of 6 months led to significant reduction in the incidence of CLABSI; however, the incidence of VAP increased.

  16. Computer-Controlled Cylindrical Polishing Process for Development of Grazing Incidence Optics for Hard X-Ray Region

    Science.gov (United States)

    Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.

  17. Poisson-Spot Intensity Reduction with a Partially-Transparent Petal-Shaped Optical Mask

    Science.gov (United States)

    Shiri, Shahram; Wasylkiwskyj, Wasyl

    2013-01-01

    The presence of Poisson's spot, also known as the spot of Arago, formed along the optical axis in the geometrical shadow behind an obstruction, has been known since the 18th century. The presence of this spot can best be described as the consequence of constructive interference of light waves diffracted on the edge of the obstruction where its central position can··be determined by the symmetry of the object More recently, the elimination of this spot has received attention in the fields of particle physics, high-energy lasers, astronomy and lithography. In this paper, we introduce a novel, partially transparent petaled mask shape that suppresses the bright spot by up to 10 orders of magnitude in intensity, with powerful applications to many of the above fields. The optimization technique formulated in this design can identify mask shapes having partial transparency only near the petal tips.

  18. Optical intensity modulation direct detection versus heterodyne detection: A high-SNR capacity comparison

    KAUST Repository

    Chaaban, Anas

    2016-09-15

    An optical wireless communications system which employs either intensity-modulation and direct-detection (IM-DD) or heterodyne detection (HD) is considered. IM-DD has lower complexity and cost than HD, but on the other hand, has lower capacity. It is therefore interesting to investigate the capacity gap between the two systems. The main focus of this paper is to investigate this gap at high SNR. Bounds on this gap are established for two cases: between IM-DD and HD, and between IM-DD and an HD-PAM which is an HD system employing pulse-amplitude modulation (PAM). While the gap between IM-DD and HD increases as the signal-to-noise ratio (SNR) increases, the gap between IM-DD and an HD-PAM is upper bounded by a constant at high SNR. © 2015 IEEE.

  19. Manipulation of the polarization of intense laser beams via optical wave mixing in plasmas

    Science.gov (United States)

    Michel, Pierre; Divol, Laurent; Turnbull, David; Moody, John

    2014-10-01

    When intense laser beams overlap in plasmas, the refractive index modulation created by the beat wave via the ponderomotive force can lead to optical wave mixing phenomena reminiscent of those used in crystals and photorefractive materials. Using a vector analysis, we present a full analytical description of the modification of the polarization state of laser beams crossing at arbitrary angles in a plasma. We show that plasmas can be used to provide full control of the polarization state of a laser beam, and give simple analytical estimates and practical considerations for the design of novel photonics devices such as plasma polarizers and plasma waveplates. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.

  20. Optical intensity modulation direct detection versus heterodyne detection: A high-SNR capacity comparison

    KAUST Repository

    Chaaban, Anas; Alouini, Mohamed-Slim

    2016-01-01

    An optical wireless communications system which employs either intensity-modulation and direct-detection (IM-DD) or heterodyne detection (HD) is considered. IM-DD has lower complexity and cost than HD, but on the other hand, has lower capacity. It is therefore interesting to investigate the capacity gap between the two systems. The main focus of this paper is to investigate this gap at high SNR. Bounds on this gap are established for two cases: between IM-DD and HD, and between IM-DD and an HD-PAM which is an HD system employing pulse-amplitude modulation (PAM). While the gap between IM-DD and HD increases as the signal-to-noise ratio (SNR) increases, the gap between IM-DD and an HD-PAM is upper bounded by a constant at high SNR. © 2015 IEEE.

  1. Incidence and Severity of Prescribing Errors in Parenteral Nutrition for Pediatric Inpatients at a Neonatal and Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Theresa Hermanspann

    2017-06-01

    Full Text Available ObjectivesPediatric inpatients are particularly vulnerable to medication errors (MEs, especially in highly individualized preparations like parenteral nutrition (PN. Aside from prescribing via a computerized physician order entry system (CPOE, we evaluated the effect of cross-checking by a clinical pharmacist to prevent harm from PN order errors in a neonatal and pediatric intensive care unit (NICU/PICU.MethodsThe incidence of prescribing errors in PN in a tertiary level NICU/PICU was surveyed prospectively between March 2012 and July 2013 (n = 3,012 orders. A pharmacist cross-checked all PN orders prior to preparation. Errors were assigned to seven different error-type categories. Three independent experts from different academic tertiary level NICUs judged the severity of each error according to the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP Index (categories A–I.ResultsThe error rate was 3.9% for all 3,012 orders (118 prescribing errors in 111 orders. 77 (6.0%, 1,277 orders errors occurred in the category concentration range, all concerning a relative overdose of calcium gluconate for peripheral infusion. The majority of all events (60% were assigned to categories C and D (without major harmful consequences while 28% could not be assigned due to missing majority decision. Potential harmful consequences requiring interventions (category E could have occurred in 12% of assessments.ConclusionNext to systematic application of clinical guidelines and prescribing via CPOE, order review by a clinical pharmacist is still required to effectively reduce MEs and thus to prevent minor and major adverse drug events with the aim to enhance medication safety.

  2. Layered ACO-OFDM for intensity-modulated direct-detection optical wireless transmission.

    Science.gov (United States)

    Wang, Qi; Qian, Chen; Guo, Xuhan; Wang, Zhaocheng; Cunningham, David G; White, Ian H

    2015-05-04

    Layered asymmetrically clipped optical orthogonal frequency division multiplexing (ACO-OFDM) with high spectral efficiency is proposed in this paper for optical wireless transmission employing intensity modulation with direct detection. In contrast to the conventional ACO-OFDM, which only utilizes odd subcarriers for modulation, leading to an obvious spectral efficiency loss, in layered ACO-OFDM, the subcarriers are divided into different layers and modulated by different kinds of ACO-OFDM, which are combined for simultaneous transmission. In this way, more subcarriers are used for data transmission and the spectral efficiency is improved. An iterative receiver is also proposed for layered ACO-OFDM, where the negative clipping distortion of each layer is subtracted once it is detected so that the signals from different layers can be recovered. Theoretical analysis shows that the proposed scheme can improve the spectral efficiency by up to 2 times compared with conventional ACO-OFDM approaches with the same modulation order. Meanwhile, simulation results confirm a considerable signal-to-noise ratio gain over ACO-OFDM at the same spectral efficiency.

  3. Low Intensity Post Process Tuning of Optical Properties of Polymer-Plasmonic Nanoparticle Hybrids

    Science.gov (United States)

    Mahoney, Clare; Park, Kyoungweon; Vaia, Richard

    The ability to fabricate flat optics with graded refractive indices through patterned plasmonic properties is attractive for compact photonics devices. Because simultaneous self-assembly of different nanostructures within a singular film is challenging, recent efforts have shifted towards post processing methods. For example, lasers coupled to surface plasmon resonances (SPR) can induce reshaping, but often times require intense power densities that damage the matrix. Herein, we demonstrate a lower temperature approach to nanostructure reshaping based on photo-thermal triggered local redox chemistry. Xe-lamp is shown to provide volume-conserved reshaping of gold nanrods (AuNRs) dispersed within polyvinyl alcohol . Within seconds, the aspect ratio can be reduced from 5.5 to 1 (>500 nm shift in the LSPR) while maintaining particle dispersion and alignment. Using the irradiation profile and matrix thermal diffusivity, gradient resolutions of 3 nm LSPR shift per micron are seen both spatially and through thickness. Furthermore, the polarization sensitivity of the LSPR enables polarization control in reshaping. Such scalable and energy efficient plasmonic post processes will be crucial to optical-nanocomposites into future technologies. National Academy of Sciences, NRC.

  4. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    Science.gov (United States)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  5. Longitudinal relationship between traumatic brain injury and the risk of incident optic neuropathy: A 10-year follow-up nationally representative Taiwan survey.

    Science.gov (United States)

    Chen, Ying-Jen; Liang, Chang-Min; Tai, Ming-Cheng; Chang, Yun-Hsiang; Lin, Tzu-Yu; Chung, Chi-Hsiang; Lin, Fu-Huang; Tsao, Chang-Huei; Chien, Wu-Chien

    2017-10-17

    Accumulating evidences had shown that traumatic brain injury was associated with visual impairment or vision loss. However, there were a limited number of empirical studies regarding the longitudinal relationship between traumatic brain injury and incident optic neuropathy. We studied a cohort from the Taiwanese National Health Insurance data comprising 553918 participants with traumatic brain injury and optic neuropathy-free in the case group and 1107836 individuals without traumatic brain injury in the control group from 1st January 2000. After the index date until the end of 2010, Cox proportional hazards analysis was used to compare the risk of incident optic neuropathy. During the follow-up period, case group was more likely to develop incident optic neuropathy (0.24%) than the control group (0.11%). Multivariate Cox regression analysis demonstrated that the case group had a 3-fold increased risk of optic neuropathy (HR = 3.017, 95% CI = 2.767-3.289, p optic neuropathy. Our study provided evidence of the increased risk of incident optic neuropathy after traumatic brain injury during a 10-year follow-up period. Patients with traumatic brain injury required periodic and thorough eye examinations for incident optic neuropathy to prevent potentially irreversible vision loss.

  6. Quantum key distribution with an efficient countermeasure against correlated intensity fluctuations in optical pulses

    Science.gov (United States)

    Yoshino, Ken-ichiro; Fujiwara, Mikio; Nakata, Kensuke; Sumiya, Tatsuya; Sasaki, Toshihiko; Takeoka, Masahiro; Sasaki, Masahide; Tajima, Akio; Koashi, Masato; Tomita, Akihisa

    2018-03-01

    Quantum key distribution (QKD) allows two distant parties to share secret keys with the proven security even in the presence of an eavesdropper with unbounded computational power. Recently, GHz-clock decoy QKD systems have been realized by employing ultrafast optical communication devices. However, security loopholes of high-speed systems have not been fully explored yet. Here we point out a security loophole at the transmitter of the GHz-clock QKD, which is a common problem in high-speed QKD systems using practical band-width limited devices. We experimentally observe the inter-pulse intensity correlation and modulation pattern-dependent intensity deviation in a practical high-speed QKD system. Such correlation violates the assumption of most security theories. We also provide its countermeasure which does not require significant changes of hardware and can generate keys secure over 100 km fiber transmission. Our countermeasure is simple, effective and applicable to wide range of high-speed QKD systems, and thus paves the way to realize ultrafast and security-certified commercial QKD systems.

  7. On the Capacity Region of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2015-08-11

    The capacity of the intensity-modulation direct-detection free-space optical broadcast channel (OBC) is investigated. The Gaussian model with input-independent Gaussian noise is used, with both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans\\' approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian distributions or discrete distributions. While the discrete input distribution achieves higher rates than the truncated-Gaussian distribution, the latter allows expressing the achievable rate region in a closed form. At high signal-to-noise ratio (SNR), it is shown that the truncated-Gaussian distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows large. It also achieves the capacity region within a constant gap, which depends on the number of users. At low SNR, it is shown that on-off keying with time-division multiple-access (TDMA) is optimal, as it achieves any point on the boundary of the developed outer bound. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves a fairly good performance in terms of symmetric rate.

  8. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  9. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2016-01-12

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  10. Intense transient electric field sensor based on the electro-optic effect of LiNbO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qing, E-mail: yangqing@cqu.edu.cn; Sun, Shangpeng; Han, Rui; Sima, Wenxia; Liu, Tong [State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing, 400044 (China)

    2015-10-15

    Intense transient electric field measurements are widely applied in various research areas. An optical intense E-field sensor for time-domain measurements, based on the electro-optic effect of lithium niobate, has been studied in detail. Principles and key issues in the design of the sensor are presented. The sensor is insulated, small in size (65 mm × 15 mm × 15 mm), and suitable for high-intensity (<801 kV/m) electric field measurements over a wide frequency band (10 Hz–10 MHz). The input/output characteristics of the sensor were obtained and the sensor calibrated. Finally, an application using this sensor in testing laboratory lightning impulses and in measuring transient electric fields during switch-on of a disconnector confirmed that the sensor is expected to find widespread use in transient intense electric field measurement applications.

  11. Dependence of laser radiation intensity on the elastic deformation of a revolving optical disk with a reflective coating

    Science.gov (United States)

    Gladyshev, V. O.; Portnov, D. I.

    2016-12-01

    The physical mechanism of alteration of intensity of linearly polarized monochromatic electromagnetic radiation with λ = 630 nm in a revolving dielectric disk with a mirror coating is examined. The effect is induced by elastic deformation due to the revolution and by thermoelastic deformation of the optically transparent disk. These deformations result in birefringence, the polarization plane rotation, and a 30-40% change in the intensity of reflected radiation.

  12. The effects of intense laser field and applied electric and magnetic fields on optical properties of an asymmetric quantum well

    Energy Technology Data Exchange (ETDEWEB)

    Restrepo, R.L., E-mail: pfrire@eia.edu.co [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Escuela de Ingeniería de Antioquia-EIA, Envigado (Colombia); Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia-UdeA, Calle 70 No. 52-21, Medellín (Colombia); Ungan, F.; Kasapoglu, E. [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Mora-Ramos, M.E. [Facultad de Ciencias, Universidad Autonóma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Morales, A.L.; Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia-UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2015-01-15

    This paper presents the results of the theoretical study of the effects of non-resonant intense laser field and electric and magnetic fields on the optical properties (the linear and third-order nonlinear refractive index and absorption coefficients) in an asymmetric quantum well. The electric field and intense laser field are applied along the growth direction of the asymmetric quantum well and the magnetic field is oriented perpendicularly. To calculate the energy and the wave functions of the electron in the asymmetric quantum well, the effective mass approximation and the method of envelope wave function are used. The asymmetric quantum well is constructed by using different aluminium concentrations in both right and left barriers. The confinement in the quantum well is changed drastically by either the effect of electric and magnetic fields or by the application of intense laser field. The optical properties are calculated using the compact density matrix approach. The results show that the effect of the intense laser field competes with the effects of the electric and magnetic fields. Consequently, peak position shifts to lower photon energies due to the effect of the intense laser field and it shifts to higher photon energies by the effects of electric and magnetic fields. In general, it is found that the concentration of aluminum, electric and magnetic fields and intense laser field are external agents that modify the optical responses in the asymmetric quantum well.

  13. Poststroke delirium incidence and outcomes: validation of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU).

    Science.gov (United States)

    Mitasova, Adela; Kostalova, Milena; Bednarik, Josef; Michalcakova, Radka; Kasparek, Tomas; Balabanova, Petra; Dusek, Ladislav; Vohanka, Stanislav; Ely, E Wesley

    2012-02-01

    To describe the epidemiology and time spectrum of delirium using Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria and to validate a tool for delirium assessment in patients in the acute poststroke period. A prospective observational cohort study. The stroke unit of a university hospital. A consecutive series of 129 patients with stroke (with infarction or intracerebral hemorrhage, 57 women and 72 men; mean age, 72.5 yrs; age range, 35-93 yrs) admitted to the stroke unit of a university hospital were evaluated for delirium incidence. None. Criterion validity and overall accuracy of the Czech version of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) were determined using serial daily delirium assessments with CAM-ICU by a junior physician compared with delirium diagnosis by delirium experts using the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria that began the first day after stroke onset and continued for at least 7 days. Cox regression models using time-dependent covariate analysis adjusting for age, gender, prestroke dementia, National Institutes of Stroke Health Care at admission, first-day Sequential Organ Failure Assessment, and asphasia were used to understand the relationships between delirium and clinical outcomes. An episode of delirium based on reference Diagnostic and Statistical Manual assessment was detected in 55 patients with stroke (42.6%). In 37 of these (67.3%), delirium began within the first day and in all of them within 5 days of stroke onset. A total of 1003 paired CAM-ICU/Diagnostic and Statistical Manual of Mental Disorders daily assessments were completed. Compared with the reference standard for diagnosing delirium, the CAM-ICU demonstrated a sensitivity of 76% (95% confidence interval [CI] 55% to 91%), a specificity of 98% (95% CI 93% to 100%), an overall accuracy of 94% (95% CI 88% to 97%), and high interrater reliability (κ = 0.94; 95% CI 0

  14. Readmission to the Intensive Care Unit: Incidence, Risk Factors, Resource Use, and Outcomes. A Retrospective Cohort Study.

    Science.gov (United States)

    Ponzoni, Carolina R; Corrêa, Thiago D; Filho, Roberto R; Serpa Neto, Ary; Assunção, Murillo S C; Pardini, Andreia; Schettino, Guilherme P P

    2017-08-01

    Readmission to the intensive care unit (ICU) is associated with poor clinical outcomes, increased length of ICU and hospital stay, and higher costs. Nevertheless, knowledge of epidemiology of ICU readmissions, risk factors, and attributable outcomes is restricted to developed countries. To determine the effect of ICU readmissions on in-hospital mortality, determine incidence of ICU readmissions, identify predictors of ICU readmissions and hospital mortality, and compare resource use and outcomes between readmitted and nonreadmitted patients in a developing country. This retrospective single-center cohort study was conducted in a 40-bed, open medical-surgical ICU of a private, tertiary care hospital in São Paulo, Brazil. The Local Ethics Committee at Hospital Israelita Albert Einstein approved the study protocol, and the need for informed consent was waived. All consecutive adult (≥18 yr) patients admitted to the ICU between June 1, 2013 and July 1, 2015 were enrolled in this study. Comparisons were made between patients readmitted and not readmitted to the ICU. Logistic regression analyses were performed to identify predictors of ICU readmissions and hospital mortality. Out of 5,779 patients admitted to the ICU, 576 (10%) were readmitted to the ICU during the same hospitalization. Compared with nonreadmitted patients, patients readmitted to the ICU were more often men (349 of 576 patients [60.6%] vs. 2,919 of 5,203 patients [56.1%]; P = 0.042), showed a higher (median [interquartile range]) severity of illness (Simplified Acute Physiology III score) at index ICU admission (50 [41-61] vs. 42 [32-54], respectively, for readmitted and nonreadmitted patients; P Simplified Acute Physiology III score (P < 0.001), ICU admission from the ward (odds ratio [OR], 1.907; 95% confidence interval [CI], 1.463-2.487; P < 0.001), vasopressors need during index ICU stay (OR, 1.391; 95% CI, 1.130-1.713; P = 0.002), and length of ICU stay (P = 0.001) were

  15. Optical diffraction tomography microscopy with transport of intensity equation using a light-emitting diode array

    Science.gov (United States)

    Li, Jiaji; Chen, Qian; Zhang, Jialin; Zhang, Zhao; Zhang, Yan; Zuo, Chao

    2017-08-01

    Optical diffraction tomography (ODT) is an effective label-free technique for quantitatively refractive index imaging, which enables long-term monitoring of the internal three-dimensional (3D) structures and molecular composition of biological cells with minimal perturbation. However, existing optical tomographic methods generally rely on interferometric configuration for phase measurement and sophisticated mechanical systems for sample rotation or beam scanning. Thereby, the measurement is suspect to phase error coming from the coherent speckle, environmental vibrations, and mechanical error during data acquisition process. To overcome these limitations, we present a new ODT technique based on non-interferometric phase retrieval and programmable illumination emitting from a light-emitting diode (LED) array. The experimental system is built based on a traditional bright field microscope, with the light source replaced by a programmable LED array, which provides angle-variable quasi-monochromatic illumination with an angular coverage of ±37 degrees in both x and y directions (corresponding to an illumination numerical aperture of ∼0.6). Transport of intensity equation (TIE) is utilized to recover the phase at different illumination angles, and the refractive index distribution is reconstructed based on the ODT framework under first Rytov approximation. The missing-cone problem in ODT is addressed by using the iterative non-negative constraint algorithm, and the misalignment of the LED array is further numerically corrected to improve the accuracy of refractive index quantification. Experiments on polystyrene beads and thick biological specimens show that the proposed approach allows accurate refractive index reconstruction while greatly reduced the system complexity and environmental sensitivity compared to conventional interferometric ODT approaches.

  16. Incidence and Outcomes of Optical Zone Enlargement and Recentration After Previous Myopic LASIK by Topography-Guided Custom Ablation.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Carp, Glenn I; Stuart, Alastair J; Rowe, Elizabeth L; Nesbit, Andrew; Moore, Tara

    2018-02-01

    To report the incidence, visual and refractive outcomes, optical zone enlargement, and recentration using topography-guided CRS-Master TOSCA II software with the MEL 80 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) after primary myopic laser refractive surgery. Retrospective analysis of 73 eyes (40 patients) with complaints of night vision disturbances due to either a decentration or small optical zone following a primary myopic laser refractive surgery procedure using the MEL 80 laser. Multiple ATLAS topography scans were imported into the CRS-Master software for topography-guided ablation planning. The topography-guided re-treatment procedure was performed as either a LASIK flap lift, a new LASIK flap, a side cut only, or photorefractive keratectomy. Axial curvature maps were analyzed using a fixed grid and set of concentric circles superimposed to measure the topographic optical zone diameter and centration. Follow-up was 12 months. The incidence of use in the population of myopic treatments during the study period was 0.79% (73 of 9,249). The optical zone diameter was increased by 11% from a mean of 5.65 to 6.32 mm, with a maximum change of 2 mm in one case. Topographic decentration was reduced by 64% from a mean of 0.58 to 0.21 mm. There was a 44% reduction in spherical aberration, 53% reduction in coma, and 39% reduction in total higher order aberrations. A subjective improvement in night vision symptoms was reported by 93%. Regarding efficacy, 82% of eyes reached 20/20 and 100% reached 20/32 (preoperative CDVA was 20/20 or better in 90%). Regarding safety, no eyes lost two lines of CDVA and 27% gained one line. Regarding predictability, 71% of re-treatments were within ±0.50 diopters. Topography-guided ablation was effective in enlarging the optical zone, recentering the optical zone, and reducing higher order aberrations. Topography-guided custom ablation appears to be an effective method for re-treatment procedures of symptomatic patients after

  17. Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Erik A. [Los Alamos National Laboratory

    2012-06-07

    Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity

  18. Results after implementation of a protocol on the incidence of urinary tract infection in an intensive care unit.

    Science.gov (United States)

    Miranda, Anna Letícia; Oliveira, Ana Lúcia Lyrio de; Nacer, Daiana Terra; Aguiar, Cynthia Adalgisa Mesojedovas

    2016-09-09

    to compare the results of urinary tract infection incidence, by means of the rate of indwelling urethral catheter use, and to identify microorganisms in urine cultures and surveillance cultures before and after the implementation of a clinical protocol for intensive care unit patients . urinary tract infection is defined as a positive urine culture > 105 CFU/mL, notified by the hospital infection control service, six months before and after the implementation of the protocol. The sample consisted of 47 patients, 28 reported before and 19 after implementation. The protocol established in the institution is based on the Ministry of Health manual to prevent healthcare-related infections; the goal is patient safety and improving the quality of health services. a negative linear correlation was observed between the later months of implementation and the reduction of reported cases of urinary tract infection, using the Spearman rank order coefficient (p = 0.045), and a reduction in the number of urine culture microorganisms (p = 0.026) using the Fisher exact test. educational interventions with implementation protocols in health institutions favor the standardization of maintenance of the invasive devices, which may reduce colonization and subsequent infections. comparar os resultados da incidência de infecção do trato urinário, por meio da taxa de utilização do cateter vesical de demora e identificar os micro-organismos na urocultura e cultura de vigilância antes e após a implementação de um protocolo assistencial em pacientes internados em unidade de terapia intensiva. definiu-se infecção do trato urinário pacientes com urocultura positiva >105 UFC/mL, notificados pelo Serviço de Controle de Infecção Hospitalar, seis meses antes e após a implementação do protocolo. A amostra foi constituída por 47 pacientes, sendo 28 notificados antes e 19 após. O protocolo, criado na instituição, é baseado no manual do Ministério da Saúde na prevenção de

  19. Linear optical absorption spectra of mesoscopic structures in intense THz fields: Free-particle properties

    DEFF Research Database (Denmark)

    Johnsen, Kristinn; Jauho, Antti-Pekka

    1998-01-01

    We theoretically study the effect of THz radiation on the linear optical absorption spectra of semiconductor structures. A general theoretical framework, based on nonequilibrium Green functions, is formulated and applied to the calculation of linear optical absorption spectrum for several...

  20. A dynamic plasmonic manipulation technique assisted by phase modulation of an incident optical vortex beam

    International Nuclear Information System (INIS)

    Yuan, G H; Wang, Q; Tan, P S; Lin, J; Yuan, X-C

    2012-01-01

    A novel phase modulation method for dynamic manipulation of surface plasmon polaritons (SPPs) with a phase engineered optical vortex (OV) beam illuminating on nanoslits is experimentally demonstrated. Because of the unique helical phase carried by an OV beam, dynamic control of SPP multiple focusing and standing wave generation is realized by changing the OV beam’s topological charge constituent with the help of a liquid-crystal spatial light modulator. Measurement of SPP distributions with near-field scanning optical microscopy showed an excellent agreement with numerical predictions. The proposed phase modulation technique for manipulating SPPs features has seemingly dynamic and reconfigurable advantages, with profound potential for development of SPP coupling, routing, multiplexing and high-resolution imaging devices on plasmonic chips. (paper)

  1. Grazing Incidence Wavefront Sensing and Verification of X-Ray Optics Performance

    Science.gov (United States)

    Saha, Timo T.; Rohrbach, Scott; Zhang, William W.

    2011-01-01

    Evaluation of interferometrically measured mirror metrology data and characterization of a telescope wavefront can be powerful tools in understanding of image characteristics of an x-ray optical system. In the development of soft x-ray telescope for the International X-Ray Observatory (IXO), we have developed new approaches to support the telescope development process. Interferometrically measuring the optical components over all relevant spatial frequencies can be used to evaluate and predict the performance of an x-ray telescope. Typically, the mirrors are measured using a mount that minimizes the mount and gravity induced errors. In the assembly and mounting process the shape of the mirror segments can dramatically change. We have developed wavefront sensing techniques suitable for the x-ray optical components to aid us in the characterization and evaluation of these changes. Hartmann sensing of a telescope and its components is a simple method that can be used to evaluate low order mirror surface errors and alignment errors. Phase retrieval techniques can also be used to assess and estimate the low order axial errors of the primary and secondary mirror segments. In this paper we describe the mathematical foundation of our Hartmann and phase retrieval sensing techniques. We show how these techniques can be used in the evaluation and performance prediction process of x-ray telescopes.

  2. Optical Analysis of Grazing Incidence Ring Resonators for Free-Electron Lasers

    Science.gov (United States)

    Gabardi, David Richard

    1990-08-01

    The design of resonators for free-electron lasers (FELs) which are to operate in the soft x-ray/vacuum ultraviolet (XUV) region of the spectrum is complicated by the fact that, in this wavelength regime, normal incidence mirrors, which would otherwise be used for the construction of the resonators, generally have insufficient reflectivities for this purpose. However, the use of grazing incidence mirrors in XUV resonators offers the possibility of (1) providing sufficient reflectivity, (2) a lessening of the mirrors' thermal loads due to the projection of the laser beam onto an oblique surface, and (3) the preservation of the FEL's tunability. In this work, the behavior of resonators employing grazing incidence mirrors in ring type configurations is explored. In particular, two designs, each utilizing four off-axis conic mirrors and a number of flats, are examined. In order to specify the location, orientation, and surface parameters for the mirrors in these resonators, a design algorithm has been developed based upon the properties of Gaussian beam propagation. Two computer simulation methods are used to perform a vacuum stability analysis of the two resonator designs. The first method uses paraxial ray trace techniques with the resonators' thin lens analogues while the second uses the diffraction-based computer simulation code GLAD (General Laser Analysis and Design). The effects of mirror tilts and deviations in the mirror surface parameters are investigated for a number of resonators designed to propagate laser beams of various Rayleigh ranges. It will be shown that resonator stability decreases as the laser wavelength for which the resonator was designed is made smaller. In addition, resonator stability will also be seen to decrease as the amount of magnification the laser beam receives as it travels around the resonator is increased.

  3. Which aspects of safety culture predict incident reporting behavior in neonatal intensive care units? A multilevel analysis

    NARCIS (Netherlands)

    Snijders, Cathelijne; Kollen, Boudewijn J.; van Lingen, Richard A.; Fetter, Willem P. F.; Molendijk, Harry; Kok, J. H.; te Pas, E.; Pas, H.; van der Starre, C.; Bloemendaal, E.; Lopes Cardozo, R. H.; Molenaar, A. M.; Giezen, A.; van Lingen, R. A.; Maat, H. E.; Molendijk, A.; Snijders, C.; Lavrijssen, S.; Mulder, A. L. M.; de Kleine, M. J. K.; Koolen, A. M. P.; Schellekens, M.; Verlaan, W.; Vrancken, S.; Fetter, W. P. F.; Schotman, L.; van der Zwaan, A.; van der Tuijn, Y.; Tibboel, D.; van der Schaaf, T. W.; Klip, H.; Kollen, B. J.

    2009-01-01

    OBJECTIVES: Safety culture assessments are increasingly used to evaluate patient-safety programs. However, it is not clear which aspects of safety culture are most relevant in understanding incident reporting behavior, and ultimately improving patient safety. The objective of this study was to

  4. Mounting for Fabrication, Metrology, and Assembly of Full Shell Grazing Incidence Optics

    Science.gov (United States)

    Roche, Jacqueline M.; Gubarev, Mikhail V.; O'Dell, Stephen L.; Kolodziejczak, Jeffery; Weisskopf, Martin C.; Ramsey, Brian D.; Elsner, Ronald F.

    2014-01-01

    Future x-ray telescopes will likely require lightweight mirrors to attain the large collecting areas needed to accomplish the science objectives. Understanding and demonstrating processes now is critical to achieving sub-arcsecond performance in the future. Consequently, designs not only of the mirrors but of fixtures for supporting them during fabrication, metrology, handling, assembly, and testing must be adequately modeled and verified. To this end, MSFC is using finite-element modeling to study the effects of mounting on full-shell grazing-incidence mirrors, during all processes leading to flight mirror assemblies. Here we report initial results of this study.

  5. Incidence, outcome and risk factors for sepsis - a two year retrospective study at surgical intensive care unit of a teaching hospital in Pakistan

    International Nuclear Information System (INIS)

    Asghar, A.; Hashmi, M.; Rashid, S.; Khan, F.H.

    2016-01-01

    Background: Sepsis is amongst the leading causes of admission to the intensive care units and is associated with a high mortality. However, data from developing countries is scarse. Aim of conducting this study was to determine the incidence, outcome and risk factors for sepsis on admission to surgical intensive care unit (SICU) of a teaching hospital in Pakistan. Methods: Two year retrospective observational study included all consecutive adult admissions to the surgical intensive care unit (SICU) of a University Hospital, from January 2012 to December 2013. Results: Two hundred and twenty-nine patients met the inclusion criteria. Average age of the patients was 46.35±18.23 years (16-85), mean Acute Physiology and Chronic Health Evaluation II (APACHE II) score was 15.92±8.13 and males were 67.6 percentage. Median length of ICU stay was 4 [IQR 5]. 43 percentage patients fulfilled the criteria of sepsis at the time of admission to the SICU and incidence of severe sepsis/septic shock was 35 percentage. Abdominal sepsis was the most frequent source of infection (57.5 percentage). The overall intensive care unit mortality was 32.31 percentage but the mortality of sepsis-group was 51.15 percentage as compared to 17.7 percentage of the non-sepsis group. Stepwise logistic regression model showed that increasing age, female gender, non-operative admission, admission under general surgery and co-morbidities like ischaemic heart disease and chronic kidney disease were significant predictors of sepsis. Conclusion: The incidence of sepsis and severe sepsis/septic shock, on admission to SICU is high and mortality of the sepsis group is nearly three times the mortality of the non-sepsis group. (author)

  6. An intensive study on the optical, rheological, and electrokinetic properties of polyvinyl alcohol-capped nanogold

    Science.gov (United States)

    Behera, Manoranjan

    2015-05-01

    Low-temperature-assisted wet chemical synthesis of nanogold (NG) using gold hydroxide, a new precursor salt in the presence of a macroscopic ligand poly(vinyl alcohol) PVA in water in the form of nanofluid, is reported for the first time in this article. In the absorption spectra, the surface Plasmon resonance absorption band in the range of 520-545 nm signifies the formation of NG via a controlled Au3+ + 3e → Au reaction grafted in small assemblies with polymer. Absorption maximum increases nonlinearly with Au-contents up to 100 µM Au in Au-PVA charge-transfer complex. Marked enhancement in the peak intensity of some of the vibration bands of PVA polymer such as C-H stretching, C=O stretching, CH2 bending, and C-C in-plane bending in the presence of NG reveals an interfacial interaction between NG and oxidized PVA via C=O group. Execution of shear thinning behavior regardless of the Au-content strongly suggests that crosslinking exists between NG and PVA in Au-PVA rheo-optical nanofluids. Hydrodynamic diameter and polydispersity index draw a nonlinear path with the Au doping with 30.0 g/L PVA in water over a wide region of 5-100 μM Au covered in this study. Enhancement in the zetapotential of Au-PVA nanofluid over bare PVA in water is ascribed to buildup of nonbonding electrons of "-C=O" moieties from the oxidized PVA on the NG surface. Displaying of lattice fringes in the microscopic image of core-shell Au-PVA nanostructure confirms that crystalline nature of NG core with inter planar spacing 0.235 nm corresponds to Au (111) plane.

  7. Optical Coherence Tomography Minimum Intensity as an Objective Measure for the Detection of Hydroxychloroquine Toxicity.

    Science.gov (United States)

    Allahdina, Ali M; Stetson, Paul F; Vitale, Susan; Wong, Wai T; Chew, Emily Y; Ferris, Fredrick L; Sieving, Paul A; Cukras, Catherine

    2018-04-01

    As optical coherence tomography (OCT) minimum intensity (MI) analysis provides a quantitative assessment of changes in the outer nuclear layer (ONL), we evaluated the ability of OCT-MI analysis to detect hydroxychloroquine toxicity. Fifty-seven predominantly female participants (91.2% female; mean age, 55.7 ± 10.4 years; mean time on hydroxychloroquine, 15.0 ± 7.5 years) were enrolled in a case-control study and categorized into affected (i.e., with toxicity, n = 19) and unaffected (n = 38) groups using objective multifocal electroretinographic (mfERG) criteria. Spectral-domain OCT scans of the macula were analyzed and OCT-MI values quantitated for each subfield of the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. A two-sample U-test and a cross-validation approach were used to assess the sensitivity and specificity of toxicity detection according to OCT-MI criteria. The medians of the OCT-MI values in all nine of the ETDRS subfields were significantly elevated in the affected group relative to the unaffected group (P < 0.005 for all comparisons), with the largest difference found for the inner inferior subfield (P < 0.0001). The receiver operating characteristic analysis of median MI values of the inner inferior subfields showed high sensitivity and high specificity in the detection of toxicity with area under the curve = 0.99. Retinal changes secondary to hydroxychloroquine toxicity result in increased OCT reflectivity in the ONL that can be detected and quantitated using OCT-MI analysis. Analysis of OCT-MI values demonstrates high sensitivity and specificity for detecting the presence of hydroxychloroquine toxicity in this cohort and may contribute additionally to current screening practices.

  8. Pump-to-Signal Intensity Modulation Transfer in Saturated- Gain Fiber Optical Parametric Amplifiers

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke; Rottwitt, Karsten

    2011-01-01

    The pump-to-signal intensity modulation transfer in saturated degenerate FOPAs is numerically investigated over the whole gain bandwidth. The intensity modulation transfer decreases and the OSNR improves when the amplifier operates in the saturation regime....

  9. Statistical properties of intensity of partially polarised semiconductor laser light backscattered by a single-mode optical fibre

    International Nuclear Information System (INIS)

    Alekseev, A E; Potapov, V T; Gorshkov, B G

    2015-01-01

    We report the results of studying statistical properties of the intensity of partially polarised coherent light backscattered by a single mode optical fibre. An expression is derived for the deviation of the backscattered light intensity depending on the scattering region length, the degree of the light source coherence and the degree of scattered light polarisation. It is shown that the backscattered light in a fibre scattered-light interferometer is partially polarised with the polarisation degree P = 1/3 in the case of external perturbations of the interferometer fibre. (scattering of light)

  10. Incidence and evolution of subretinal precipitates in optic disc pit maculopathy.

    Science.gov (United States)

    Chatziralli, Irini; Theodossiadis, George; Brouzas, Dimitrios; Theodossiadis, Panagiotis

    2017-06-26

    To study the evolution of subretinal precipitates coexistent with optic disc pit (ODP) maculopathy from their appearance at baseline examination until their absorption after successful treatment. Participants in this retrospective, multicenter study were 42 patients with ODP maculopathy, in whom complete ocular examination was performed, including visual acuity (VA) measurement, slit-lamp examination, color or red-free fundus photography, and optical coherence tomography at baseline after surgical treatment. Out of 42 cases, 17 (40.5%) cases of ODP maculopathy, which were examined between 2002 and 2015, were found to have subretinal precipitates associated with multilayer fluid accumulation at baseline. Precipitates were located at the outer part of the photoreceptor layer and remained for 3-6 months after successful treatment and absorption of subretinal fluid. The mean VA was 0.99 ± 0.21 logMAR at baseline and improved to 0.54 ± 0.25 logMAR at the final examination. Macular precipitates in association with signs of disease chronicity, such as multilayer fluid accumulation, became evident at baseline examination. Precipitates' disappearance in 15 out of 17 cases coincided with the absorption of subretinal fluid. The relative low VA at baseline probably could be attributed to the chronicity of the disease.

  11. Pre-operative use of dexamethasone does not reduce incidence or intensity of bleaching-induced tooth sensitivity. A triple-blind, parallel-design, randomized clinical trial.

    Science.gov (United States)

    da Costa Poubel, Luiz Augusto; de Gouvea, Cresus Vinicius Deppes; Calazans, Fernanda Signorelli; Dip, Etyene Castro; Alves, Wesley Veltri; Marins, Stella Soares; Barcelos, Roberta; Barceleiro, Marcos Oliveira

    2018-04-25

    This study evaluated the effect of the administration of pre-operative dexamethasone on tooth sensitivity stemming from in-office bleaching. A triple-blind, parallel-design, randomized clinical trial was conducted on 70 volunteers who received dexamethasone or placebo capsules. The drugs were administered in a protocol of three daily 8-mg doses of the drug, starting 48 h before the in-office bleaching treatment. Two bleaching sessions with 37.5% hydrogen peroxide gel were performed with a 1-week interval. Tooth sensitivity (TS) was recorded on visual analog scales (VAS) and numeric rating scales (NRS) in different periods up to 48 h after bleaching. The color evaluations were also performed. The absolute risk of TS and its intensity were evaluated by using Fisher's exact test. Comparisons of the TS intensity (NRS and VAS data) were performed by using the Mann-Whitney U test and a two-way repeated measures ANOVA and Tukey's test, respectively. In both groups, a high risk of TS (Dexa 80% x Placebo 94%) was detected. No significant difference was observed in terms of TS intensity. A whitening of approximately 3 shade guide units of the VITA Classical was detected in both groups, which were statistically similar. It was concluded that the administration pre-operatively of dexamethasone, in the proposed protocol, does not reduce the incidence or intensity of bleaching-induced tooth sensitivity. The use of dexamethasone drug before in-office bleaching treatment does not reduce incidence or intensity of tooth sensitivity. NCT02956070.

  12. Soft X-ray images of the solar corona using normal incidence optics

    Science.gov (United States)

    Bruner, M. E.; Haisch, B. M.; Brown, W. A.; Acton, L. W.; Underwood, J. H.

    1988-01-01

    A solar coronal loop system has been photographed in soft X-rays using a normal incidence telescope based on multilayer mirror technology. The telescope consisted of a spherical objective mirror of 4 cm aperture and 1 m focal length, a film cassette, and a focal plane shutter. A metallized thin plastic film filter was used to exclude visible light. The objective mirror was covered with a multilayer coating consisting of alternating layers of tungsten and carbon whose combined thicknesses satisfied the Bragg diffraction condition for 44 A radiation. The image was recorded during a rocket flight on October 25, 1985 and was dominated by emission lines arising from the Si XII spectrum. The rocket also carried a high resolution soft X-ray spectrograph that confirmed the presence of Si XII line radiation in the source. This image represents the first successful use of multilayer technology for astrophysical observations.

  13. Amplification of the Signal Intensity of Fluorescence-Based Fiber-Optic Biosensors Using a Fabry-Perot Resonator Structure

    Directory of Open Access Journals (Sweden)

    Meng-Chang Hsieh

    2015-02-01

    Full Text Available Fluorescent biosensors have been widely used in biomedical applications. To amplify the intensity of fluorescence signals, this study developed a novel structure for an evanescent wave fiber-optic biosensor by using a Fabry-Perot resonator structure. An excitation light was coupled into the optical fiber through a laser-drilled hole on the proximal end of the resonator. After entering the resonator, the excitation light was reflected back and forth inside the resonator, thereby amplifying the intensity of the light in the fiber. Subsequently, the light was used to excite the fluorescent molecules in the reactive region of the sensor. The experimental results showed that the biosensor signal was amplified eight-fold when the resonator reflector was formed using a 92% reflective coating. Furthermore, in a simulation, the biosensor signal could be amplified 20-fold by using a 99% reflector.

  14. Spectrally and Energy Efficient OFDM (SEE-OFDM) for Intensity Modulated Optical Wireless Systems

    OpenAIRE

    Lam, Emily; Wilson, Sarah Kate; Elgala, Hany; Little, Thomas D. C.

    2015-01-01

    Spectrally and energy efficient orthogonal frequency division multiplexing (SEE-OFDM) is an optical OFDM technique based on combining multiple asymmetrically clipped optical OFDM (ACO-OFDM) signals into one OFDM signal. By summing different components together, SEE-OFDM can achieve the same spectral efficiency as DC-biased optical OFDM (DCO-OFDM) without an energy-inefficient DC-bias. This paper introduces multiple methods for decoding a SEE-OFDM symbol and shows that an iterative decoder wit...

  15. Cocaine-related admissions to an intensive care unit: a five-year study of incidence and outcomes.

    LENUS (Irish Health Repository)

    Galvin, S

    2010-02-01

    Cocaine misuse is increasing and it is evidently considered a relatively safe drug of abuse in Ireland. To address this perception, we reviewed the database of an 18-bed Dublin intensive care unit, covering all admissions from 2003 to 2007. We identified cocaine-related cases, measuring hospital mortality and long-term survival in early 2009. Cocaine-related admissions increased from around one annually in 2003-05 to 10 in 2007. Their median (IQR [range]) age was 25 (21-35 [17-47]) years and 78% were male. The median (IQR [range]) APACHE II score was 16 (11-27 [5-36]) and length of intensive care stay was 5 (3-9 [1-16]) days. Ten patients died during their hospital stay. A further five had died by the time of follow-up, a median of 24 months later. One was untraceable. Cocaine toxicity necessitating intensive care is increasingly common in Dublin. Hospital mortality in this series was 52%. These findings may help to inform public attitudes to cocaine.

  16. Incidence of carbapenem resistant nonfermenting gram negative bacilli from patients with respiratory infections in the intensive care units

    Directory of Open Access Journals (Sweden)

    Gladstone P

    2005-01-01

    Full Text Available Resistance to carbapenems is commonly seen in nonfermenting gram negative bacilli (NFGNB. We document herein the prevalence of carbapenem resistance in NFGNB isolated from patients with respiratory tract infections in the intensive care units (ICUs. A total of 460 NFGNB were isolated from 606 endotracheal aspirate specimens during January through December 2003, of which 56 (12.2% were found to be resistant to imipenem and meropenem. Of these, 24 (42.8% were Pseudomonas aeruginosa , 8 (14.2% were Acinetobacter spp. and 24 (42.8% were other NFGNB. Stringent protocols such as antibiotic policies and resistance surveillance programs are mandatory to curb these bacteria in ICU settings.

  17. Analysis of intensive aerosol optical properties measured at the Jungfraujoch station

    Energy Technology Data Exchange (ETDEWEB)

    Li, F.; Nyeki, S.; Baltensperger, U.; Weingartner, E.; Lugauer, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Characterisation of atmospheric aerosol optical properties at the Jungfraujoch has been conducted to deliver basic data for comparison with those from NOAA baseline atmospheric monitoring stations. (author) 2 figs., 2 refs.

  18. Aerodynamic Effects of High Turbulence Intensity on a Variable-Speed Power-Turbine Blade With Large Incidence and Reynolds Number Variations

    Science.gov (United States)

    Flegel, Ashlie B.; Giel, Paul W.; Welch, Gerard E.

    2014-01-01

    The effects of high inlet turbulence intensity on the aerodynamic performance of a variable speed power turbine blade are examined over large incidence and Reynolds number ranges. These results are compared to previous measurements made in a low turbulence environment. Both high and low turbulence studies were conducted in the NASA Glenn Research Center Transonic Turbine Blade Cascade Facility. The purpose of the low inlet turbulence study was to examine the transitional flow effects that are anticipated at cruise Reynolds numbers. The current study extends this to LPT-relevant turbulence levels while perhaps sacrificing transitional flow effects. Assessing the effects of turbulence at these large incidence and Reynolds number variations complements the existing database. Downstream total pressure and exit angle data were acquired for 10 incidence angles ranging from +15.8deg to -51.0deg. For each incidence angle, data were obtained at five flow conditions with the exit Reynolds number ranging from 2.12×10(exp 5) to 2.12×10(exp 6) and at a design exit Mach number of 0.72. In order to achieve the lowest Reynolds number, the exit Mach number was reduced to 0.35 due to facility constraints. The inlet turbulence intensity, Tu, was measured using a single-wire hotwire located 0.415 axial-chord upstream of the blade row. The inlet turbulence levels ranged from 8 to 15 percent for the current study. Tu measurements were also made farther upstream so that turbulence decay rates could be calculated as needed for computational inlet boundary conditions. Downstream flow field measurements were obtained using a pneumatic five-hole pitch/yaw probe located in a survey plane 7 percent axial chord aft of the blade trailing edge and covering three blade passages. Blade and endwall static pressures were acquired for each flow condition as well. The blade loading data show that the suction surface separation that was evident at many of the low Tu conditions has been eliminated. At

  19. An image-processing method to detect sub-optical features based on understanding noise in intensity measurements.

    Science.gov (United States)

    Bhatia, Tripta

    2018-02-01

    Accurate quantitative analysis of image data requires that we distinguish between fluorescence intensity (true signal) and the noise inherent to its measurements to the extent possible. We image multilamellar membrane tubes and beads that grow from defects in the fluid lamellar phase of the lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine dissolved in water and water-glycerol mixtures by using fluorescence confocal polarizing microscope. We quantify image noise and determine the noise statistics. Understanding the nature of image noise also helps in optimizing image processing to detect sub-optical features, which would otherwise remain hidden. We use an image-processing technique "optimum smoothening" to improve the signal-to-noise ratio of features of interest without smearing their structural details. A high SNR renders desired positional accuracy with which it is possible to resolve features of interest with width below optical resolution. Using optimum smoothening, the smallest and the largest core diameter detected is of width [Formula: see text] and [Formula: see text] nm, respectively, discussed in this paper. The image-processing and analysis techniques and the noise modeling discussed in this paper can be used for detailed morphological analysis of features down to sub-optical length scales that are obtained by any kind of fluorescence intensity imaging in the raster mode.

  20. Incidence and distribution of transplantable organs from donors after circulatory determination of death in U.S. intensive care units.

    Science.gov (United States)

    Halpern, Scott D; Hasz, Richard D; Abt, Peter L

    2013-04-01

    All U.S. acute care hospitals must maintain protocols for recovering organs from donors after circulatory determination of death (DCDD), but the numbers, types, and whereabouts of available organs are unknown. To assess the maximal potential supply and distribution of DCDD organs in U.S. intensive care units. We conducted a population-based cohort study among a randomly selected sample of 50 acute care hospitals in the highest-volume donor service area in the United States. We identified all potentially eligible donors dying within 90 minutes of the withdrawal of life-sustaining therapy from July 1, 2008 to June 30, 2009. Using prespecified criteria, potential donors were categorized as optimal, suboptimal, or ineligible to donate their lungs, kidneys, pancreas, or liver. If only optimal DCDD organs were used, the deceased donor supplies of these organs could increase by up to 22.7, 8.9, 7.4, and 3.3%, respectively. If optimal and suboptimal DCDD organs were used, the corresponding supply increases could be up to 50.0, 19.7, 18.5, and 10.9%. Three-quarters of DCDD organs could be recovered from the 17.2% of hospitals with the highest annual donor volumes-typically those with trauma centers and more than 20 intensive care unit beds. Universal identification and referral of DCDD could increase the supply of transplantable lungs by up to one-half, and would not increase any other organ supply by more than one-fifth. The marked clustering of DCDD among a small number of identifiable hospitals could guide targeted interventions to improve DCDD identification, referral, and management.

  1. Device-associated infections among neonatal intensive care unit patients: incidence and associated pathogens reported to the National Healthcare Safety Network, 2006-2008.

    Science.gov (United States)

    Hocevar, Susan N; Edwards, Jonathan R; Horan, Teresa C; Morrell, Gloria C; Iwamoto, Martha; Lessa, Fernanda C

    2012-12-01

    To describe rates and pathogen distribution of device-associated infections (DAIs) in neonatal intensive care unit (NICU) patients and compare differences in infection rates by hospital type (children's vs general hospitals). Neonates in NICUs participating in the National Healthcare Safety Network from 2006 through 2008. We analyzed central line-associated bloodstream infections (CLABSIs), umbilical catheter-associated bloodstream infections (UCABs), and ventilator-associated pneumonia (VAP) among 304 NICUs. Differences in pooled mean incidence rates were examined using Poisson regression; nonparametric tests for comparing medians and rate distributions were used. Pooled mean incidence rates by birth weight category (750 g or less, 751-1,000 g, 1,001-1,500 g, 1,501-2,500 g, and more than 2,500 g, respectively) were 3.94, 3.09, 2.25, 1.90, and 1.60 for CLABSI; 4.52, 2.77, 1.70, 0.91, and 0.92 for UCAB; and 2.36, 2.08, 1.28, 0.86, and 0.72 for VAP. When rates of infection between hospital types were compared, only pooled mean VAP rates were significantly lower in children's hospitals than in general hospitals among neonates weighing 1,000 g or less; no significant differences in medians or rate distributions were noted. Pathogen frequencies were coagulase-negative staphylococci (28%), Staphylococcus aureus (19%), and Candida species (13%) for bloodstream infections and Pseudomonas species (16%), S. aureus (15%), and Klebsiella species (14%) for VAP. Of 673 S. aureus isolates with susceptibility results, 33% were methicillin resistant. Neonates weighing 750 g or less had the highest DAI incidence. With the exception of VAP, pooled mean NICU incidence rates did not differ between children's and general hospitals. Pathogens associated with these infections can pose treatment challenges; continued efforts at prevention need to be applied to all NICU settings.

  2. Percutaneous dilatational tracheostomy without fiber optic bronchoscopy-Evaluation of 80 intensive care units cases

    NARCIS (Netherlands)

    J.A. Calvache (Jose Andrés); R.A. Molina García (Rodrigo); A.L. Trochez (Adolfo); J. Benitez (Javier); L.A. Flga (Lucía Arroyo)

    2013-01-01

    textabstractBackground: The development of percutaneous dilatational tracheostomy techniques (PDT) has facilitated the procedure in Intensive Care Units (ICU). Objective: To describe the early intra and post-operative complications in ICU patients requiring percutaneous dilatational tracheostomy

  3. Ultrasonic modulation of tissue optical properties in ex vivo porcine skin to improve transmitted transdermal laser intensity.

    Science.gov (United States)

    Whiteside, Paul J D; Qian, Chenxi; Golda, Nicholas; Hunt, Heather K

    2017-09-01

    Applications of light-based energy devices involving optical targets within the dermis frequently experience negative side-effects resultant from surface scattering and excess optical absorption by epidermal melanin. As a broadband optical absorber, melanin decreases the efficacy of light-based treatments throughout the ultraviolet, visible, and near-infrared spectra while also generating additional heat within the surface tissue that can lead to inflammation or tissue damage. Consequently, procedures may be performed using greater energy densities to ensure that the target receives a clinically relevant dose of light; however, such practices are limited, as doing so tends to exacerbate the detrimental complications resulting from melanin absorption of treatment light. The technique presented herein represents an alternative method of operation aimed at increasing epidermal energy fluence while mitigating excess absorption by unintended chromophores. The approach involves the application of continuously pulsed ultrasound to modulate the tissue's optical properties and thereby improve light transmission through the epidermis. To demonstrate the change in optical properties, pulsed light at a wavelength of 532 nm from a Q-switched Nd:YAG laser was transmitted into 4 mm thick samples of porcine skin, comprised of both epidermal and dermal tissue. The light was transmitted using an optical waveguide, which allowed for an ultrasonic transducer to be incorporated for simultaneous paraxial pulsation in parallel with laser operation. Light transmitted through the tissue was measured by a photodiode attached to an integrating sphere. Increasing the driving voltage of ultrasonic pulsation resulted in an increase in mean transmitted optical power of up to a factor of 1.742 ± 0.0526 times the control, wherein no ultrasound was applied, after which the optical power increase plateaued to an average amplification factor of 1.733 ± 0.549 times the control. The

  4. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    International Nuclear Information System (INIS)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-01-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band (<5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is -110 dB/Hz, with uncertainty ≤0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by ≤0.2 dB. [copyright] 2001 Optical Society of America

  5. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    Energy Technology Data Exchange (ETDEWEB)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-06-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band ({lt}5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is {minus}110 dB/Hz, with uncertainty {le}0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by {le}0.2 dB. {copyright} 2001 Optical Society of America

  6. Non-interferometric determination of optical anisotropy in highly-oriented fibres using transport intensity equation technique

    Science.gov (United States)

    Sokkar, T. Z. N.; El-Farahaty, K. A.; El-Bakary, M. A.; Raslan, M. I.; Omar, E. Z.; Hamza, A. A.

    2018-03-01

    The optical setup of the transport intensity equation (TIE) technique is developed to be valid for measuring the optical properties of the highly-oriented anisotropic fibres. This development is based on the microstructure models of the highly-oriented anisotropic fibres and the principle of anisotropy. We provide the setup of TIE technique with polarizer which is controlled via stepper motor. This developed technique is used to investigate the refractive indices in the parallel and perpendicular polarization directions of light for the highly-oriented poly (ethylene terephthalate) (PET) fibres and hence its birefringence. The obtained results through the developed TIE technique for PET fibre are compared with that determined experimentally using the Mach-Zehnder interferometer under the same conditions. The comparison shows a good agreement between the obtained results from the developed technique and that obtained from the Mach-Zehnder interferometer technique.

  7. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposure

    Czech Academy of Sciences Publication Activity Database

    Khorsand, A.R.; Sobierajski, R.; Louis, E.; Bruijn, S.; van Hattum, E.D.; van de Kruijs, R.W.E.; Jurek, M.; Klinger, D.; Pelka, J. B.; Juha, Libor; Burian, Tomáš; Chalupský, Jaromír; Cihelka, Jaroslav; Hájková, Věra; Vyšín, Luděk; Jastrow, U.; Stojanovic, N.; Toleikis, S.; Wabnitz, H.; Tiedtke, K.; Sokolowski-Tinten, K.; Shymanovich, U.; Krzywinski, J.; Hau-Riege, S.; London, R.; Gleeson, A.; Gullikson, E.M.; Bijkerk, F.

    2010-01-01

    Roč. 18, č. 2 (2010), 700-712 ISSN 1094-4087 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : laser damage * thermal effects * multilayers * optical design and fabrication * free-electron lasers Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.749, year: 2010

  8. A Self-Referenced Optical Intensity Sensor Network Using POFBGs for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Alberto Tapetado Moraleda

    2014-12-01

    Full Text Available This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG and polymer FBGs (POFBG is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown.

  9. A self-referenced optical intensity sensor network using POFBGs for biomedical applications.

    Science.gov (United States)

    Tapetado Moraleda, Alberto; Sánchez Montero, David; Webb, David J; Vázquez García, Carmen

    2014-12-12

    This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF)-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG) and polymer FBGs (POFBG) is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown.

  10. Incidence and Risk Factors for Delirium among Mechanically Ventilated Patients in an African Intensive Care Setting: An Observational Multicenter Study

    Directory of Open Access Journals (Sweden)

    Arthur Kwizera

    2015-01-01

    Full Text Available Aim. Delirium is common among mechanically ventilated patients in the intensive care unit (ICU. There are little data regarding delirium among mechanically ventilated patients in Africa. We sought to determine the burden of delirium and associated factors in Uganda. Methods. We conducted a multicenter prospective study among mechanically ventilated patients in Uganda. Eligible patients were screened daily for delirium using the confusional assessment method (CAM-ICU. Comparisons were made using t-test, chi-squares, and Fisher’s exact test. Predictors were assessed using logistic regression. The level of statistical significance was set at P<0.05. Results. Of 160 patients, 81 (51% had delirium. Median time to onset of delirium was 3.7 days. At bivariate analysis, history of mental illness, sedation, multiorgan dysfunction, neurosurgery, tachypnea, low mean arterial pressure, oliguria, fevers, metabolic acidosis, respiratory acidosis, anaemia, physical restraints, marital status, and endotracheal tube use were significant predictors. At multivariable analysis, having a history of mental illness, sedation, respiratory acidosis, higher PEEP, endotracheal tubes, and anaemia predicted delirium. Conclusion. The prevalence of delirium in a young African population is lower than expected considering the high mortality. A history of mental illness, anaemia, sedation, endotracheal tube use, and respiratory acidosis were factors associated with delirium.

  11. Aerodynamic Effects of Turbulence Intensity on a Variable-Speed Power-Turbine Blade with Large Incidence and Reynolds Number Variations

    Science.gov (United States)

    Flegel, Ashlie Brynn; Giel, Paul W.; Welch, Gerard E.

    2014-01-01

    The effects of inlet turbulence intensity on the aerodynamic performance of a variable speed power turbine blade are examined over large incidence and Reynolds number ranges. Both high and low turbulence studies were conducted in the NASA Glenn Research Center Transonic Turbine Blade Cascade Facility. The purpose of the low inlet turbulence study was to examine the transitional flow effects that are anticipated at cruise Reynolds numbers. The high turbulence study extends this to LPT-relevant turbulence levels while perhaps sacrificing transitional flow effects. Downstream total pressure and exit angle data were acquired for ten incidence angles ranging from +15.8 to 51.0. For each incidence angle, data were obtained at five flow conditions with the exit Reynolds number ranging from 2.12105 to 2.12106 and at a design exit Mach number of 0.72. In order to achieve the lowest Reynolds number, the exit Mach number was reduced to 0.35 due to facility constraints. The inlet turbulence intensity, Tu, was measured using a single-wire hotwire located 0.415 axial-chord upstream of the blade row. The inlet turbulence levels ranged from 0.25 - 0.4 for the low Tu tests and 8- 15 for the high Tu study. Tu measurements were also made farther upstream so that turbulence decay rates could be calculated as needed for computational inlet boundary conditions. Downstream flow field measurements were obtained using a pneumatic five-hole pitchyaw probe located in a survey plane 7 axial chord aft of the blade trailing edge and covering three blade passages. Blade and endwall static pressures were acquired for each flow condition as well. The blade loading data show that the suction surface separation that was evident at many of the low Tu conditions has been eliminated. At the extreme positive and negative incidence angles, the data show substantial differences in the exit flow field. These differences are attributable to both the higher inlet Tu directly and to the thinner inlet endwall

  12. Effects of high light intensities on the optical Kerr nonlinearity of semiconducting polymers

    International Nuclear Information System (INIS)

    Charra, Fabrice

    1990-01-01

    Experimental investigations, in the picosecond time scale, of the Kerr type optical nonlinearity (or pump and probe) are presented. The nonlinear molecules semiconducting polymers of the type poly-diacetylene. The degenerate case (pump and probe at the same frequency) has been studied by four wave mixing at 1064 nm, in the configuration of phase conjugation. It is shown that the response is dominated by high orders of nonlinearity. The results are analysed in terms of two photon resonance. The non-degenerate case is studied by two wave mixing or in the optical Kerr gate experiment. The optical Stark effect and the differential spectra of photoinduced species are analysed. Two photon excitations at 1064 nm and one photon excitations at 532 nm are compared. A consequence of the mechanism of the nonlinearity is the possibility of generating phase conjugate waves at double frequency. The theoretical analysis and the experimental demonstration of this process are presented. The experiment is only sensitive to nonlinearities of the fifth order or more and thus allows to clarify its origins and dynamics. Finally, quantum modelling and calculations of the nonlinear optical responses, developed for the interpretations of the above experiments, are presented. (author) [fr

  13. Transformation of Didactic Intensions by Teachers: The Case of Geometrical Optics in Grade 8.

    Science.gov (United States)

    Hirn, Colette; Viennot, Laurence

    2000-01-01

    Investigates the idea that teachers are not passive transmitters, and that some general trends can be found in the way they transform proposed strategies. Presents the case of elementary optics in grade 8 in France in which four sets of data--interviews before teaching, logbooks, assessment tasks, and video-recorded class observations--lead to…

  14. How diffusivity, thermocline and incident light intensity modulate the dynamics of deep chlorophyll maximum in Tyrrhenian Sea.

    Directory of Open Access Journals (Sweden)

    Davide Valenti

    Full Text Available During the last few years theoretical works have shed new light and proposed new hypotheses on the mechanisms which regulate the spatio-temporal behaviour of phytoplankton communities in marine pelagic ecosystems. Despite this, relevant physical and biological issues, such as effects of the time-dependent mixing in the upper layer, competition between groups, and dynamics of non-stationary deep chlorophyll maxima, are still open questions. In this work, we analyze the spatio-temporal behaviour of five phytoplankton populations in a real marine ecosystem by using a one-dimensional reaction-diffusion-taxis model. The study is performed, taking into account the seasonal variations of environmental variables, such as light intensity, thickness of upper mixed layer and profiles of vertical turbulent diffusivity, obtained starting from experimental findings. Theoretical distributions of phytoplankton cell concentration was converted in chlorophyll concentration, and compared with the experimental profiles measured in a site of the Tyrrhenian Sea at four different times (seasons of the year, during four different oceanographic cruises. As a result we find a good agreement between theoretical and experimental distributions of chlorophyll concentration. In particular, theoretical results reveal that the seasonal changes of environmental variables play a key role in the phytoplankton distribution and determine the properties of the deep chlorophyll maximum. This study could be extended to other marine ecosystems to predict future changes in the phytoplankton biomass due to global warming, in view of devising strategies to prevent the decline of the primary production and the consequent decrease of fish species.

  15. Low Group Delay Dispersion Optical Coating for Broad Bandwidth High Reflection at 45° Incidence, P Polarization of Femtosecond Pulses with 900 nm Center Wavelength

    Directory of Open Access Journals (Sweden)

    John C. Bellum

    2016-03-01

    Full Text Available We describe an optical coating design suitable for broad bandwidth high reflection (BBHR at 45° angle of incidence (AOI, P polarization (Ppol of femtosecond (fs laser pulses whose wavelengths range from 800 to 1000 nm. Our design process is guided by quarter-wave HR coating properties. The design must afford low group delay dispersion (GDD for reflected light over the broad, 200 nm bandwidth in order to minimize temporal broadening of the fs pulses due to dispersive alteration of relative phases between their frequency components. The design should also be favorable to high laser-induced damage threshold (LIDT. We base the coating on TiO2/SiO2 layer pairs produced by means of e-beam evaporation with ion-assisted deposition, and use OptiLayer Thin Film Software to explore designs starting with TiO2/SiO2 layers having thicknesses in a reverse chirped arrangement. This approach led to a design with R > 99% from 800 to 1000 nm and GDD < 20 fs2 from 843 to 949 nm (45° AOI, Ppol. The design’s GDD behaves in a smooth way, suitable for GDD compensation techniques, and its electric field intensities show promise for high LIDTs. Reflectivity and GDD measurements for the initial test coating indicate good performance of the BBHR design. Subsequent coating runs with improved process calibration produced two coatings whose HR bands satisfactorily meet the design goals. For the sake of completeness, we summarize our previously reported transmission spectra and LIDT test results with 800 ps, 8 ps and 675 fs pulses for these two coatings, and present a table of the LIDT results we have for all of our TiO2/SiO2 BBHR coatings, showing the trends with test laser pulse duration from the ns to sub-ps regimes.

  16. Incidence and Determinants of Health Care-Associated Blood Stream Infection at a Neonatal Intensive Care Unit in Ujjain, India: A Prospective Cohort Study

    Directory of Open Access Journals (Sweden)

    Mamta Dhaneria

    2018-01-01

    Full Text Available Very little is known about laboratory-confirmed blood stream infections (LCBIs in neonatal intensive care units (NICUs in resource-limited settings. The aim of this cohort study was to determine the incidence, risk factors, and causative agents of LCBIs in a level-2 NICU in India. The diagnosis of LCBIs was established using the Centre for Disease Control, USA criteria. A predesigned questionnaire containing risk factors associated with LCBIs was filled-in. A total of 150 neonates (43% preterm were included in the study. The overall incidence of LCBIs was 31%. The independent risk factors for LCBIs were: preterm neonates (relative risk (RR 2.23, duration of NICU stay more than 14 days (RR 1.75, chorioamnionitis in the mother (RR 3.18, premature rupture of membrane in mothers (RR 2.32, neonate born through meconium-stained amniotic fluid (RR 2.32, malpresentation (RR 3.05, endotracheal intubation (RR 3.41, umbilical catheterization (RR 4.18, and ventilator-associated pneumonia (RR 3.17. The initiation of minimal enteral nutrition was protective from LCBIs (RR 0.22. The predominant causative organisms were gram-negative pathogens (58%. The results of the present study can be used to design and implement antibiotic stewardship policy and introduce interventions to reduce LCBIs in resource-limited settings.

  17. Correlations in photon-numbers and integrated intensities in parametric processes involving three optical fields

    Czech Academy of Sciences Publication Activity Database

    Peřina, Jan; Křepelka, Jaromír; Peřina ml., Jan; Bondani, M.; Allevi, A.; Andreoni, A.

    2009-01-01

    Roč. 53, č. 3 (2009), 373-382 ISSN 1434-6060 R&D Projects: GA AV ČR KAN301370701; GA MŠk(CZ) 1M06002 Institutional research plan: CEZ:AV0Z10100522 Keywords : parametric process * three-mode state * sub-Poisson statistics * conditional measurement Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.420, year: 2009

  18. Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States); Dickerson, Bryan [Luna Innovations, Inc. (United States)

    2013-01-03

    The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica's optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and

  19. Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to High Temperature

    International Nuclear Information System (INIS)

    Blue, Thomas; Windl, Wolfgang; Dickerson, Bryan

    2013-01-01

    The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica'@@s optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and

  20. Ischemic Optic Neuropathy in Cardiac Surgery: Incidence and Risk Factors in the United States from the National Inpatient Sample 1998 to 2013.

    Science.gov (United States)

    Rubin, Daniel S; Matsumoto, Monica M; Moss, Heather E; Joslin, Charlotte E; Tung, Avery; Roth, Steven

    2017-05-01

    Ischemic optic neuropathy is the most common form of perioperative visual loss, with highest incidence in cardiac and spinal fusion surgery. To date, potential risk factors have been identified in cardiac surgery by only small, single-institution studies. To determine the preoperative risk factors for ischemic optic neuropathy, the authors used the National Inpatient Sample, a database of inpatient discharges for nonfederal hospitals in the United States. Adults aged 18 yr or older admitted for coronary artery bypass grafting, heart valve repair or replacement surgery, or left ventricular assist device insertion in National Inpatient Sample from 1998 to 2013 were included. Risk of ischemic optic neuropathy was evaluated by multivariable logistic regression. A total of 5,559,395 discharges met inclusion criteria with 794 (0.014%) cases of ischemic optic neuropathy. The average yearly incidence was 1.43 of 10,000 cardiac procedures, with no change during the study period (P = 0.57). Conditions increasing risk were carotid artery stenosis (odds ratio, 2.70), stroke (odds ratio, 3.43), diabetic retinopathy (odds ratio, 3.83), hypertensive retinopathy (odds ratio, 30.09), macular degeneration (odds ratio, 4.50), glaucoma (odds ratio, 2.68), and cataract (odds ratio, 5.62). Female sex (odds ratio, 0.59) and uncomplicated diabetes mellitus type 2 (odds ratio, 0.51) decreased risk. The incidence of ischemic optic neuropathy in cardiac surgery did not change during the study period. Development of ischemic optic neuropathy after cardiac surgery is associated with carotid artery stenosis, stroke, and degenerative eye conditions.

  1. Intensity-modulated polarizabilities and magic trapping of alkali-metal and divalent atoms in infrared optical lattices

    Science.gov (United States)

    Topcu, Turker; Derevianko, Andrei

    2014-05-01

    Long range interactions between neutral Rydberg atoms has emerged as a potential means for implementing quantum logical gates. These experiments utilize hyperfine manifold of ground state atoms to act as a qubit basis, while exploiting the Rydberg blockade mechanism to mediate conditional quantum logic. The necessity for overcoming several sources of decoherence makes magic wavelength trapping in optical lattices an indispensable tool for gate experiments. The common wisdom is that atoms in Rydberg states see trapping potentials that are essentially that of a free electron, and can only be trapped at laser intensity minima. We show that although the polarizability of a Rydberg state is always negative, the optical potential can be both attractive or repulsive at long wavelengths (up to ~104 nm). This opens up the possibility of magic trapping Rydberg states with ground state atoms in optical lattices, thereby eliminating the necessity to turn off trapping fields during gate operations. Because the wavelengths are near the CO2 laser band, the photon scattering and the ensuing motional heating is also reduced compared to conventional traps near low lying resonances, alleviating an important source of decoherence. This work was supported by the National Science Foundation (NSF) Grant No. PHY-1212482.

  2. Combined optical and electrical effects in ferroelectric crystal for high laser intensities

    Science.gov (United States)

    Kukhtarev, N. V.; Kukhtareva, T. V.; Stargell, G.; Wang, J. C.

    2009-08-01

    In this study, we have derived equations for the pyroelectric and photogalvanic contribution to the electrical charging of the photosensitive ferroelectric crystal. Standard photorefractive equations are supplemented by the equation of state for the polarization density following the Devonshire-Ginsburg-Landau (DGL) approach. The photogalvanic voltage and current is considered for a wide intensity range, which includes the CW and the pulsed photo-excitation with high intensities when the impurity is fully ionized and when the traditional linear-recombination approach is not valid. The crystal electrostatic accelerators, based on charging of ferroelectric crystals by pyroelectric and photogalvanic effects, are discussed in relation to the generation of the self-focused electron beam, X-rays, and neutrons.

  3. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas

    2018-02-19

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  4. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2018-01-01

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  5. Progress in Y-00 physical cipher for Giga bit/sec optical data communications (intensity modulation method)

    Science.gov (United States)

    Hirota, Osamu; Futami, Fumio

    2014-10-01

    To guarantee a security of Cloud Computing System is urgent problem. Although there are several threats in a security problem, the most serious problem is cyber attack against an optical fiber transmission among data centers. In such a network, an encryption scheme on Layer 1(physical layer) with an ultimately strong security, a small delay, and a very high speed should be employed, because a basic optical link is operated at 10 Gbit/sec/wavelength. We have developed a quantum noise randomied stream cipher so called Yuen- 2000 encryption scheme (Y-00) during a decade. This type of cipher is a completely new type random cipher in which ciphertext for a legitimate receiver and eavesdropper are different. This is a condition to break the Shannon limit in theory of cryptography. In addition, this scheme has a good balance on a security, a speed and a cost performance. To realize such an encryption, several modulation methods are candidates such as phase-modulation, intensity-modulation, quadrature amplitude modulation, and so on. Northwestern university group demonstrated a phase modulation system (α=η) in 2003. In 2005, we reported a demonstration of 1 Gbit/sec system based on intensity modulation scheme(ISK-Y00), and gave a design method for quadratic amplitude modulation (QAM-Y00) in 2005 and 2010. An intensity modulation scheme promises a real application to a secure fiber communication of current data centers. This paper presents a progress in quantum noise randomized stream cipher based on ISK-Y00, integrating our theoretical and experimental achievements in the past and recent 100 Gbit/sec(10Gbit/sec × 10 wavelengths) experiment.

  6. Neuromorphic optical sensor chip with color change-intensity change disambiguation

    Science.gov (United States)

    Fu, ZhenHong; Mao, Rui; Cartwright, Alexander N.; Titus, Albert H.

    2010-02-01

    In this paper, we describe the development of a novel, retina-like neuromorphic chip that has an array of two types of retina 'cells' arranged to mimic the fovea structure in certain animals. One of the two retina cell types performs irradiance detection and the other can perform color detection. Together, via the two parallel pathways the retina chip can perform color change intensity change disambiguation (CCICD). The irradiance detection cell has a wide-dynamic detection range that spans almost 3 orders of magnitude. The color detection cell has a buried double junction (BDJ) photodiode as the photoreceptor followed by two parallel logarithmic I-V convertors. The output from this is a color response which has at least a 50nm resolution for wavelengths from 400nm to 900nm. With these two cells, the array can perform color change -intensity change disambiguation (CCICD) to determine if a change in the output of the irradiance pathway is because of irradiance change, color change, or both. This biological retina-like neuromorphic sensor array is implemented in ON-SEMI 0.5μm technology, a standard CMOS fabrication process available at MOSIS.

  7. Simulations of Beam Optics and Bremsstrahlung for High Intensity and Brightness Channeling Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, J. [Sokendai, Tsukuba; Piot, P. [NIU, DeKalb; Sen, T. [Fermilab

    2018-04-12

    This paper presents X-ray spectra of channeling radiation expected at the FAST (Fermi Accelerator Science and Technology) facility in Fermilab. Our purpose is to produce high brightness quasi-monochromatic X-rays in an energy range from 40 keV to 110 keV. We will use a diamond crystal and low emittance electrons with an energy of around 43 MeV. The quality of emitted X-rays depends on parameters of the electron beam at the crystal. We present simulations of the beam optics for high brightness and high yield operations for a range of bunch charges. We estimate the X-ray spectra including bremsstrahlung background. We discuss how the electron beam distributions after the diamond crystal are affected by channeling. We discuss an X-ray detector system to avoid pile-up effects during high charge operations.

  8. Intense source of spin-polarized electrons using laser-induced optical pumping

    International Nuclear Information System (INIS)

    Gray, L.G.; Giberson, K.W.; Cheng, C.; Keiffer, R.S.; Dunning, F.B.; Walters, G.K.

    1983-01-01

    A source of spin-polarized electrons based on a laser-pumped flowing helium afterglow is described. He(2 3 S) atoms contained in the afterglow are optically pumped using circularly polarized 1.08-μm (2 3 S→2 3 P) radiation provided by a NaF (F 2+ )( color-center laser. Spin angular momentum conservation in subsequent chemi-ionization reactions with CO 2 produces polarized electrons that are extracted from the afterglow. At low currents, < or approx. =1 μA, polarizations of approx.70%--80% are achieved. At higher currents the polarization decreases, falling to approx.40% at 50 μA. The spin polarization can be simply reversed (P→-P) and the source is suitable for use in the majority of low-energy spin-dependent scattering experiments proposed to date

  9. Large-area, high-intensity PV arrays for systems using dish concentrating optics

    Energy Technology Data Exchange (ETDEWEB)

    Ward, J.S.; Duda, A.; Zweibel, K.; Coutts, T.J. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    In this paper, the authors report on efforts to fabricate monolithic interconnected modules (MIMs) using III-V semiconductors with bandgaps appropriate for the terrestrial solar spectrum. The small size of the component cells comprising the MIM allows for operation at extremely high flux densities and relaxes the requirement for a small spot size to be generated by the optics. This makes possible a PV option for the large dish concentrator systems that have been developed by the solar thermal community for use with Stirling engines. Additionally, the highly effective back-surface reflector integrated into the MIM design is an effective tool for thermal management of the array. Development of this technology would radically alter the projections for PV manufacturing capacity because of the potential for extremely high power generation per unit area of semiconductor material.

  10. A finite Hankel algorithm for intense optical beam propagation in saturable medium

    International Nuclear Information System (INIS)

    Bardin, C.; Babuel-Peyrissac, J.P.; Marinier, J.P.; Mattar, F.P.

    1985-01-01

    Many physical problems, especially light-propagation, that involve the Laplacian operator, are naturally connected with Fourier or Hankel transforms (in case of axial symmetry), which both remove the Laplacian term in the transformed space. Sometimes the analytical calculation can be handled at its end, giving a series or an integral representation of the solution. Otherwise, an analytical pre-treatment of the original equation may be done, leading to numerical computation techniques as opposed to self-adaptive stretching and rezoning techniques, which do not use Fourier or Hankel transforms. The authors present here some basic mathematical properties of infinite and finite Hankel transform, their connection with physics and their adaptation to numerical calculation. The finite Hankel transform is well-suited to numerical computation, because it deals with a finite interval, and the precision of the calculation can be easily controlled by the number of zeros of J 0 (x) to be taken. Moreover, they use a special quadrature formula which is well connected to integral conservation laws. The inconvenience of having to sum a series is reduced by the use of vectorized computers, and in the future will be still more reduced with parallel processors. A finite-Hankel code has been performed on CRAY-XMP in order to solve the propagation of a CW optical beam in a saturable absorber. For large diffractions or when a very small radial grid is required for the description of the optical field, this FHT algorithm has been found to perform better than a direct finite-difference code

  11. Incidence of pulmonary aspergillosis and correlation of conventional diagnostic methods with nested PCR and real-time PCR assay using BAL fluid in intensive care unit patients.

    Science.gov (United States)

    Zarrinfar, Hossein; Makimura, Koichi; Satoh, Kazuo; Khodadadi, Hossein; Mirhendi, Hossein

    2013-05-01

    Although the incidence of invasive aspergillosis in the intensive care unit (ICU) is scarce, it has emerged as major problems in critically ill patients. In this study, the incidence of pulmonary aspergillosis (PA) in ICU patients has evaluated and direct microscopy and culture has compared with nested polymerase chain reaction (PCR) and real-time PCR for detection of Aspergillus fumigatus and A. flavus in bronchoalveolar lavage (BAL) samples of the patients. Thirty BAL samples obtained from ICU patients during a 16-month period were subjected to direct examinations on 20% potassium hydroxide (KOH) and culture on two culture media. Nested PCR targeting internal transcribed spacer ribosomal DNA and TaqMan real-time PCR assay targeting β-tubulin gene were used for the detection of A. fumigatus and A. flavus. Of 30 patients, 60% were men and 40% were women. The diagnosis of invasive PA was probable in 1 (3%), possible in 11 (37%), and not IPA in 18 (60%). Nine samples were positive in nested PCR including seven samples by A. flavus and two by A. fumigatus specific primers. The lowest amount of DNA that TaqMan real-time PCR could detect was ≥40 copy numbers. Only one of the samples had a positive result of A. flavus real-time PCR with Ct value of 37.5. Although a significant number of specimens were positive in nested PCR, results of this study showed that establishment of a correlation between the conventional methods with nested PCR and real-time PCR needs more data confirmed by a prospective study with a larger sample group. © 2013 Wiley Periodicals, Inc.

  12. Graphics processing unit accelerated intensity-based optical coherence tomography angiography using differential frames with real-time motion correction.

    Science.gov (United States)

    Watanabe, Yuuki; Takahashi, Yuhei; Numazawa, Hiroshi

    2014-02-01

    We demonstrate intensity-based optical coherence tomography (OCT) angiography using the squared difference of two sequential frames with bulk-tissue-motion (BTM) correction. This motion correction was performed by minimization of the sum of the pixel values using axial- and lateral-pixel-shifted structural OCT images. We extract the BTM-corrected image from a total of 25 calculated OCT angiographic images. Image processing was accelerated by a graphics processing unit (GPU) with many stream processors to optimize the parallel processing procedure. The GPU processing rate was faster than that of a line scan camera (46.9 kHz). Our OCT system provides the means of displaying structural OCT images and BTM-corrected OCT angiographic images in real time.

  13. CROSS-CORRELATION BETWEEN X-RAY AND OPTICAL/NEAR-INFRARED BACKGROUND INTENSITY FLUCTUATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell-Wynne, Ketron; Cooray, Asantha [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Xue, Yongquan [CAS Key Laboratory for Researches in Galaxies and Cosmology, Center for Astrophysics, Department of Astronomy, University of Science and Technology of China, Chinese Academy of Sciences, Hefei, Anhui 230026 (China); Luo, Bin [School of Astronomy and Space Science, Nanjing University, Nanjing, 210093 (China); Brandt, William [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA, 16802 (United States); Koekemoer, Anton [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2016-12-01

    Angular power spectra of optical and infrared background anisotropies at wavelengths between 0.5 and 5 μ m are a useful probe of faint sources present during reionization, in addition to faint galaxies and diffuse signals at low redshift. The cross-correlation of these fluctuations with backgrounds at other wavelengths can be used to separate some of these signals. A previous study on the cross-correlation between X-ray and Spitzer fluctuations at 3.6 μ m and 4.5 μ m has been interpreted as evidence for direct collapse black holes present at z  > 12. Here we return to this cross-correlation and study its wavelength dependence from 0.5 to 4.5 μ m using Hubble and Spitzer data in combination with a subset of the 4 Ms Chandra observations in GOODS-S/ECDFS. Our study involves five Hubble bands at 0.6, 0.7, 0.85, 1.25, and 1.6 μ m, and two Spitzer -IRAC bands at 3.6 μ m and 4.5 μ m. We confirm the previously seen cross-correlation between 3.6 μ m (4.5 μ m) and X-rays with 3.7 σ (4.2 σ ) and 2.7 σ (3.7 σ ) detections in the soft [0.5–2] keV and hard [2–8] keV X-ray bands, respectively, at angular scales above 20 arcsec. The cross-correlation of X-rays with Hubble is largely anticorrelated, ranging between the levels of 1.4 σ –3.5 σ for all the Hubble and X-ray bands. This lack of correlation in the shorter optical/NIR bands implies the sources responsible for the cosmic infrared background at 3.6 and 4.5 μ m are at least partly dissimilar to those at 1.6 μ m and shorter.

  14. Photoacoustic detection and optical spectroscopy of high-intensity focused ultrasound-induced thermal lesions in biologic tissue

    Energy Technology Data Exchange (ETDEWEB)

    Alhamami, Mosa; Kolios, Michael C.; Tavakkoli, Jahan, E-mail: jtavakkoli@ryerson.ca [Department of Physics, Ryerson University, 350 Victoria Street, Toronto, Ontario M5B 2K3 (Canada)

    2014-05-15

    Purpose: The aims of this study are: (a) to investigate the capability of photoacoustic (PA) method in detecting high-intensity focused ultrasound (HIFU) treatments in muscle tissuesin vitro; and (b) to determine the optical properties of HIFU-treated and native tissues in order to assist in the interpretation of the observed contrast in PA detection of HIFU treatments. Methods: A single-element, spherically concaved HIFU transducer with a centre frequency of 1 MHz was utilized to create thermal lesions in chicken breast tissuesin vitro. To investigate the detectability of HIFU treatments photoacoustically, PA detection was performed at 720 and 845 nm on seven HIFU-treated tissue samples. Within each tissue sample, PA signals were acquired from 22 locations equally divided between two regions of interest within two volumes in tissue – a HIFU-treated volume and an untreated volume. Optical spectroscopy was then carried out on 10 HIFU-treated chicken breast specimens in the wavelength range of 500–900 nm, in 1-nm increments, using a spectrophotometer with an integrating sphere attachment. The authors’ optical spectroscopy raw data (total transmittance and diffuse reflectance) were used to obtain the optical absorption and reduced scattering coefficients of HIFU-induced thermal lesions and native tissues by employing the inverse adding-doubling method. The aforementioned interaction coefficients were subsequently used to calculate the effective attenuation coefficient and light penetration depth of HIFU-treated and native tissues in the wavelength range of 500–900 nm. Results: HIFU-treated tissues produced greater PA signals than native tissues at 720 and 845 nm. At 720 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.68 ± 0.25 (mean ± standard error of the mean). At 845 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.75

  15. Effects of high-intensity interval training on optic nerve head and macular perfusion using optical coherence tomography angiography in healthy adults.

    Science.gov (United States)

    Schmitz, Boris; Nelis, Pieter; Rolfes, Florian; Alnawaiseh, Maged; Klose, Andreas; Krüger, Michael; Eter, Nicole; Brand, Stefan-Martin; Alten, Florian

    2018-07-01

    High-intensity interval training (HIIT) has been identified to be efficient for increasing health-related fitness in general and in lifestyle-induced chronic diseases such as hypertension, obesity and metabolic syndrome. This study aimed to evaluate HIIT effects on optic nerve head (ONH) and macular perfusion in healthy adults using optical coherence tomography angiography (OCTA). Fifty-eight healthy participants (22.0 ± 2.02 years, 40 females (69.0%)) performed a 4-week HIIT with two exercise sessions/week: Group 1, 4 × 30 HIIT, running at maximal speed (all-out) for 4 × 30 s with 30 s active recovery, Group 2, 8 × 15 HIIT, running at maximal speed (all-out) for 8 × 15 s with 15 s active recovery. OCTA of the ONH and the macula was performed at baseline and follow-up to detect changes of the foveal avascular zone (FAZ). Flow density was evaluated in the superficial and deep plexus of the central macula, in the radial peripapillary capillary layer, the nerve head layer of the disc region and of the peripapillary region. The mean deep FAZ area and flow density of the superficial layer decreased by 14.00 ± 13.02% and 1.26 ± 3.20%, respectively, in response to overall HIIT (pre vs. post p HIIT may be performed to induce changes in ophthalmic measures such as FAZ and nerve head perfusion. OCTA imaging of the central retina and the ONH could represent a sensitive tool for the early detection of systemic vascular changes. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Influence of ionizing radiation on optical hardness of transparent dielectrics to action of huge intensity laser light

    International Nuclear Information System (INIS)

    Bedilov, M.R.; Khalilov, R.A.

    2006-01-01

    Full text: This paper presents results of researches of optical hardness of γ -irradiated with doze 10 4 - 10 9 rad alkali-silicate (K, GLS, LGS) and quartz (KU, KV, KSG) glasses against influence of radiation neodymium laser with intensity q = 0,1-1000 GWt/cm 2 . It is observed, that the laser produces damage of surface and volume of investigated glasses before and after γ-irradiation. This damage has threshold character and is always accompanied by a bright luminescence of plasma. Definition of threshold values of intensity superficial q s and volumetric q d laser produced damage was made by the complex method - fixing the moment of damage of transparent dielectric by simultaneous registration of the laser impulse which has passed through plasma of breakdown, mass-charge spectrum of ions of plasma and measuring the energy falling on the glass, and of penetrated and mirror-image radiations; and by optical microscopy. This method of research of influence γ-induced in transparent dielectric radiating defects on its optical stability against influence of laser radiation allows not only to define values q s and q d in the investigated interval of dozes, but also to investigate in details physical phenomena taking place in this process of interaction. On the basis of the received data quantitative characteristics of optical durability of the investigated glasses on wave length of λ1,06 microns depending on dozes of γ-irradiation and intensity of laser radiation are made. Doze dependences of charge and power spectra and quantitative characteristics of ions of plasma of breakdown were investigated at q≥ q s . In the investigated interval of dozes of γ- irradiation and intensity of laser radiation by a method of optical microscopy the morphology of occurring laser damage as surfaces, and volume of glass is also studied. It is found, that γ -induced defects in investigated glasses strongly effect on thresholds of damage q s and q d and on characteristics of ions

  17. Controlling optical properties of periodic gold nanoparticle arrays by changing the substrate, topologic shapes of nanoparticles, and polarization direction of incident light

    International Nuclear Information System (INIS)

    Ting, Li; Li, Yu; Zhi-Xin, Lu; Gang, Song; Kai, Zhang

    2011-01-01

    The effects of various parameters including thickness and dielectric constants of substrates, shapes of nanoparticles, and polarization direction of incident light, on the extinction spectra of periodic gold nanoparticle arrays are investigated by the full-vectorial three-dimensional (3D) finite difference time domain (FDTD) method. The calculated results show that the substrate affects the extinction spectra by coupling the fields co-excited by the substrate and gold nanoparticles. Extinction spectra are influenced by the shapes of the nanoparticles, but there are no obvious changes in extinction spectra for similar shapes. The polarization direction of incident light has a great influence on the extinction spectra. The implications of these results are discussed. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  18. Aerosol optical, microphysical and radiative forcing properties during variable intensity African dust events in the Iberian Peninsula

    Science.gov (United States)

    Fernández, A. J.; Molero, F.; Salvador, P.; Revuelta, A.; Becerril-Valle, M.; Gómez-Moreno, F. J.; Artíñano, B.; Pujadas, M.

    2017-11-01

    Aerosol measurements at two AERONET (AErosol RObotic NETwork) sites of the Iberian Peninsula: Madrid (40°.45N, 3.72W) and La Coruña (43°.36N, 8°.42W) have been analyzed for the period 2012-2015 to assess aerosol optical properties (intensive and extensive) throughout the atmospheric column and their radiative forcing (RF) and radiative forcing efficiency (RFeff) estimates at the Bottom and Top Of Atmosphere (BOA and TOA respectively). Specific conditions as dust-free and African dust have been considered for the study. Unprecedented, this work uses the quantification of the African dust aerosol at ground level which allows us to study such AERONET products at different intensity levels of African events: Low (L), High (H) and very high (VH). The statistical difference between dust-free and African dust conditions on the aforementioned parameters, quantified by means of the non-parametric Kolmogorov-Smirnov test, is quite clear in Madrid, however it is not in La Coruña. Scattering Angstrom Exponent (SAE) and Absorption Angstrom Exponent (AAE) were found to be 1.64 ± 0.29 and 1.14 ± 0.23 respectively in Madrid for dust-free conditions because typical aerosol sources are traffic emissions and residential heating, and black carbon is an important compound in this aerosol kind. On the other hand, SAE and AAE were 0.96 ± 0.60 and 1.44 ± 0.51 for African dust conditions in this location. RF (at shortwave radiation) seems to decrease as the African dust contribution at ground level is larger which indicates the cooling effect of African dust aerosol in Madrid. We have also proved the potential of a 2D-cluster analysis based on AAE and SAE to differentiate both situations in Madrid. Conversely, it is suggested that aerosols observed in La Coruña under dust-free conditions might come from different sources. Then, SAE and AAE are not good enough indicators to distinguish between dust-free and African dust conditions. Besides, as La Coruña is at a further distance

  19. A systematics of optical model compound nucleus formation cross sections for neutrons, proton, deuteron, 3He and alpha particle incidents

    International Nuclear Information System (INIS)

    Murata, Toru

    2000-01-01

    Simple formulae to reproduce the optical model compound nucleus formation cross sections for neutron, proton, deuteron, triton, 3 He and alpha particles are presented for target nuclei of light to medium weight mass region. (author)

  20. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  1. A comparison of optic nerve dosimetry in craniospinal radiotherapy planned and treated with conventional and intensity modulated techniques

    International Nuclear Information System (INIS)

    Rene, Nicholas J.; Brodeur, Marylene; Parker, William; Roberge, David; Freeman, Carolyn

    2010-01-01

    Background and purpose: Some CNS tumours present leptomeningeal dissemination. Craniospinal radiotherapy is complex and recurrences may occur at sites of target volume underdosage. IMRT, being highly conformal to the target, could theoretically underdose the optic nerves if they are not specifically targeted leading to optic nerve recurrences. We analyzed optic nerve dosimetry when they are not specifically targeted. Materials and methods: We designed 3D-conformal and tomotherapy plans for our last five patients treated to the craniospinal axis, not including the optic nerves in the target volume. We analyzed the dose delivered to the optic nerves, to the anterior and posterior half of the optic nerves, and to a theoretical optic nerve-PTV. Results: The dose delivered to the optic nerves was similar for both plans in all patients (V95% close to 100%) except one in whom tomotherapy considerably underdosed the anterior optic nerves. The dose to the optic nerve-PTV was lower with tomotherapy in all patients. Conclusion: Despite not intentionally targeting the optic nerves, the dose to the optic nerves with IMRT was similar to 3D-conformal plans in most cases but left no margin for setup error. In individual cases the anterior half of the optic nerves could be significantly underdosed.

  2. Analysis of the incidence of postintubation injuries in patients intubated in the prehospital or early hospital conditions of the hospital emergency department and the intensive care unit

    Directory of Open Access Journals (Sweden)

    Cierniak M

    2015-10-01

    Full Text Available Marcin Cierniak,1 Dariusz Timler,1 Renata Sobczak,1 Andrzej Wieczorek,2 Przemyslaw Sekalski,3 Natalia Borkowska,2 Tomasz Gaszynski1 1Department of Emergency Medicine and Disaster Medicine, Barlicki University Hospital, 2Department of Anesthesiology and Intensive Therapy, Medical University of Lodz, 3Department of Microelectronics and Computer Science, IT Centre, Lodz University of Technology, Lodz, Poland Background: Intubation is still one of the best methods to secure the airway. In the case of prehospital or early hospital conditions when factors such as urgency, stress, or inaccuracy of the undertaken activities are involved, the risk of causing complications, for instance, edema or postintubation injuries, increases, especially while dealing with a difficult intubation. The risk of improper inflation of the endotracheal tube cuff also increases, which is considered in this study.Objective: The aim of this study was to evaluate the prevalence of postintubation complications, such as postintubation injuries or edema, in a research sample, and to examine whether such complications occur more often, for example, while using a guidewire. In this study, we also evaluated the injuries associated with the inflation of the endotracheal tube cuff.Materials and methods: This study was performed on a group of 153 patients intubated in prehospital conditions. The tests were carried out in three clinical sites that received patients from prehospital care. Postintubation injuries were revealed and photographed using videolaryngoscope, such as the C-MAC and the McGrath series 5. The endotracheal tube cuff pressure was measured using a pressure gage manual (VBM Medizintechnik GmbH. The quantitative analyses of differences between incidence of variables were assessed using χ2 test for P<0.05. Analyses have been carried out using the Statistica software.Results: In the group of 153 patients, postintubation injuries occurred in 17% of cases. The dependency

  3. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  4. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    International Nuclear Information System (INIS)

    Ungan, F.; Restrepo, R.L.; Mora-Ramos, M.E.; Morales, A.L.; Duque, C.A.

    2014-01-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga 0.7 Al 0.3 As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga 0.7 Al 0.3 As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications

  5. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    Energy Technology Data Exchange (ETDEWEB)

    Ungan, F., E-mail: fungan@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Restrepo, R.L. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Escuela de Ingeniería de Antioquia AA 7516, Medellín (Colombia); Mora-Ramos, M.E. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Facultad de Ciencias, Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Morales, A.L.; Duque, C.A. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2014-02-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications.

  6. The intermediate polar GK Persei: An unstable relation of the X-ray and the optical intensities in a series of outbursts

    Science.gov (United States)

    Šimon, V.

    2015-03-01

    Context. GK Per is an intermediate polar that has been displaying dwarf nova outbursts since the middle of the twentieth century. Aims: I analyzed a series of such outbursts in the optical and X-ray bands. I pay attention to the relation of intensities of the optical and X-ray emissions, and its reproducibility in a series of these consecutive outbursts. Methods: This analysis uses the data from the BAT/Swift, ASM/RXTE, AAVSO, and AFOEV databases. It investigates the relation of the time evolution of the profiles of outbursts in the individual bands (hard X-ray, medium/hard X-ray, and optical). Results: This analysis shows that the X-ray intensity steeply rises only in the start of the optical outburst and steeply declines only when the optical outburst comes to its end. However, the 1.5-50 keV band intensity saturates and balances on a plateau during the outburst. (The longer the outburst, the longer its plateau.) The peak X-ray intensities of this series display a significantly narrower range than the optical ones (a factor of about two versus a factor of about eight). This implies a discrepancy between the mass flow through the disk and the production of the X-ray emission via bremsstrahlung at the polar caps of the white dwarf. This discrepancy is the largest in the time of the peak optical intensity when the whole disk (or at least its inner part) is in the hot state and the flow of matter through the disk is the greatest. This study shows that a series of outbursts constitutes more general properties of this discrepancy. I argue that the saturation of the X-ray luminosity in outburst cannot be caused by a dominant increase in X-ray absorption. In the interpretation, large structural changes of the accreting regions at the magnetic poles of the white dwarf occur during the outburst. A buried shock proposed by some authors for polars is also promising for explaining the X-ray light curves of outbursts of GK Per. This research made use of the BAT/Swift, ASM

  7. Measuring high-frequency responses of an electro-optic phase modulator based on dispersion induced phase modulation to intensity modulation conversion

    Science.gov (United States)

    Zhang, Shangjian; Wang, Heng; Wang, Yani; Zou, Xinhai; Zhang, Yali; Liu, Shuang; Liu, Yong

    2014-11-01

    We investigate the phase modulation to intensity modulation conversion in dispersive fibers for measuring frequency responses of electro-optic phase modulators, and demonstrate two typical measurements with cascade path and fold-back path. The measured results achieve an uncertainty of less than 2.8% within 20 GHz. Our measurements show stable and repeatable results because the optical carrier and its phase-modulated sidebands are affected by the same fiber impairments. The proposed method requires only dispersive fibers and works without any small-signal assumption, which is applicable for swept frequency measurement at different driving levels and operating wavelengths.

  8. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  9. Optical probe

    International Nuclear Information System (INIS)

    Denis, J.; Decaudin, J.M.

    1984-01-01

    The probe includes optical means of refractive index n, refracting an incident light beam from a medium with a refractive index n1>n and reflecting an incident light beam from a medium with a refractive index n2 [fr

  10. Extremely Intensive and Conservative Fault Capability Studies on Nuclear Facilities in Japan after the 2011 Tohoku Earthquake and Fukushima Daiichi Incident

    Science.gov (United States)

    Okumura, K.

    2013-12-01

    Rocks of the Japanese islands are mostly faulted since the Mesozoic Era. The opening of the Sea of Japan in Middle Miocene stretched most of the Japanese crust together with rifting systems. Modern compressional tectonic regime started in Pliocene and accelerated during Quaternary. The ubiquitous bedrock fault prior to the Quaternary had long been regarded as incapable for the future rupturing. This view on the bedrock fault, however, is in question after the March 11, 2011 Tohoku earthquake and tsunamis. There is no scientific reason for the Tohoku earthquake to let the geologists and seismologists worry about the capability of the long-deceased fault. Neither the unexpected April 11, 2011 extensional faulting event on shore in southern Fukushima prefecture has any scientific reason as well. There was no change and no new stress field, but the psychological situation of the scientists and the public welcomed the wrong belief in unexpected stress changes all over Japan, in the same manner that the March 11 M 9 was not expected. Finally, the capabilities of the bedrock faults, fractures, and joints came up to concern about seismic safety of nuclear facilities. After the incidents, the nuclear regulation authority of Japan began reevaluation of the seismic safety of all facilities in Japan. The primary issues of the reevaluation were conjunctive multi-fault mega-earthquakes and the capabilities of the bedrock faults, precisely reflecting the Tohoku events. The former does not require immediate abandonment of a facility. However, the latter now denies any chance of continued operation. It is because of the new (July 2013) safety guide gave top priority to the capability of the displacement under a facility for the evaluation on safe operation. The guide also requires utmost deterministic manner in very conservative ways. The regulators ordered the utility companies to thoroughly examine the capability for several sites, and started review of the studies in late 2012

  11. Testing of Sapphire Optical Fiber and Sensors in Intense Radiation Fields When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States)

    2017-12-15

    The primary objective of this project was to determine the optical attenuation and signal degradation of sapphire optical fibers & sensors (temperature & strain), in-situ, operating at temperatures up to 1500°C during reactor irradiation through experiments and modeling. The results will determine the feasibility of extending sapphire optical fiber-based instrumentation to extremely high temperature radiation environments. This research will pave the way for future testing of sapphire optical fibers and fiber-based sensors under conditions expected in advanced high temperature reactors.

  12. Relaxed damage threshold intensity conditions and nonlinear increase in the conversion efficiency of an optical parametric oscillator using a bi-directional pump geometry.

    Science.gov (United States)

    Norris, G; McConnell, G

    2010-03-01

    A novel bi-directional pump geometry that nonlinearly increases the nonlinear optical conversion efficiency of a synchronously pumped optical parametric oscillator (OPO) is reported. This bi-directional pumping method synchronizes the circulating signal pulse with two counter-propagating pump pulses within a linear OPO resonator. Through this pump scheme, an increase in nonlinear optical conversion efficiency of 22% was achieved at the signal wavelength, corresponding to a 95% overall increase in average power. Given an almost unchanged measured pulse duration of 260 fs under optimal performance conditions, this related to a signal wavelength peak power output of 18.8 kW, compared with 10 kW using the traditional single-pass geometry. In this study, a total effective peak intensity pump-field of 7.11 GW/cm(2) (corresponding to 3.55 GW/cm(2) from each pump beam) was applied to a 3 mm long periodically poled lithium niobate crystal, which had a damage threshold intensity of 4 GW/cm(2), without impairing crystal integrity. We therefore prove the application of this novel pump geometry provides opportunities for power-scaling of synchronously pumped OPO systems together with enhanced nonlinear conversion efficiency through relaxed damage threshold intensity conditions.

  13. Low-Intensity Pulsed Ultrasound Protects Retinal Ganglion Cell From Optic Nerve Injury Induced Apoptosis via Yes Associated Protein

    Directory of Open Access Journals (Sweden)

    Jia-Xing Zhou

    2018-06-01

    Full Text Available Background: Low-intensity pulsed ultrasound (LIPUS has been used in clinical studies. But little is known about its effects on the central nervous system (CNS, or its mechanism of action. Retinal ganglion cells (RGCs are CNS neuronal cells that can be utilized as a classic model system to evaluate outcomes of LIPUS protection from external trauma-induced retinal injury. In this study, we aim to: (1 determine the pulse energy and the capability of LIPUS in RGC viability, (2 ascertain the protective role of LIPUS in optic nerve (ON crush-induced retinal injury, and 3 explore the cellular mechanisms of RGC apoptosis prevention by LIPUS.Methods: An ON crush model was set up to induce RGC death. LIPUS was used to treat mice eyes daily, and the retina samples were dissected for immunostaining and Western blot. The expression of yes-associated protein (YAP and apoptosis-related proteins was detected by immunostaining and Western blot in vitro and in vivo. Apoptosis of RGCs was evaluated by TUNEL staining, the survival of RGCs and retained axons were labeled by Fluoro-gold and Tuj1 antibody, respectively. Rotenone was used to set up an in vitro cellular degenerative model and siYAP was used to interfering the expression of YAP to detect the LIPUS protective function.Results: LIPUS protected RGC from loss and apoptosis in vivo and in vitro. The ratio of cleaved/pro-caspase3 also decreased significantly under LIPUS treatment. As a cellular mechanical sensor, YAP expression increased and YAP translocated to nucleus in LIPUS stimulation group, however, phospho-YAP was found to be decreased. When YAP was inhibited, the LIPUS could not protect RGC from caspase3-dependent apoptosis.Conclusion: LIPUS prevented RGCs from apoptosis in an ON crush model and in vitro cellular degenerative model, which indicates a potential treatment for further traumatic ON injury. The mechanism of protection is dependent on YAP activation and correlated with caspase-3 signaling.

  14. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  15. Soft X-ray imaging of thick carbon-based materials using the normal incidence multilayer optics.

    Science.gov (United States)

    Artyukov, I A; Feschenko, R M; Vinogradov, A V; Bugayev, Ye A; Devizenko, O Y; Kondratenko, V V; Kasyanov, Yu S; Hatano, T; Yamamoto, M; Saveliev, S V

    2010-10-01

    The high transparency of carbon-containing materials in the spectral region of "carbon window" (lambda approximately 4.5-5nm) introduces new opportunities for various soft X-ray microscopy applications. The development of efficient multilayer coated X-ray optics operating at the wavelengths of about 4.5nm has stimulated a series of our imaging experiments to study thick biological and synthetic objects. Our experimental set-up consisted of a laser plasma X-ray source generated with the 2nd harmonics of Nd-glass laser, scandium-based thin-film filters, Co/C multilayer mirror and X-ray film UF-4. All soft X-ray images were produced with a single nanosecond exposure and demonstrated appropriate absorption contrast and detector-limited spatial resolution. A special attention was paid to the 3D imaging of thick low-density foam materials to be used in design of laser fusion targets.

  16. Hot slumping glass technology for the grazing incidence optics of future missions with particular reference to IXO

    Science.gov (United States)

    Ghigo, M.; Basso, S.; Bavdaz, M.; Conconi, P.; Citterio, O.; Civitani, M.; Friedrich, P.; Gallieni, D.; Guldimann, B.; Martelli, F.; Negri, R.; Pagano, G.; Pareschi, G.; Parodi, G.; Proserpio, L.; Salmaso, B.; Scaglione, F.; Spiga, D.; Tagliaferri, G.; Terzi, L.; Tintori, M.; Vongehr, M.; Wille, E.; Winter, A.; Zambra, A.

    2010-07-01

    The mirrors of the International X-ray Observatory (IXO) consist of a large number of high quality segments delivering a spatial resolution better than 5 arcsec. A study concerning the slumping of thin glass foils for the IXO mirrors is under development in Europe, funded by ESA and led by the Brera Observatory. We are investigating two approaches, the "Direct" and "Indirect" slumping technologies, being respectively based on the use of convex and concave moulds. In the first case during the thermal cycle the optical surface of the glass is in direct contact with the mould surface, while in the second case it is the rear side of the foil which touches the master. Both approaches present pros and cons and aim of this study is also to make an assessment of both processes and to perform a trade-off between the two. The thin plates are made of D263glass produced by Schott. Each plate is 0.4 mm thick, with a reflecting area of 200 mm x 200 mm; the mould are made of Fused Silica. After the thermal cycle the slumped MPs are characterized to define their optical quality and microroughness. The adopted integration process foresees the bonding of the slumped foils to a rigid backplane by means of reinforcing ribs. During the bonding process the plates are constrained to stay in close contact to the surface of the master (i.e. the same mould used for the hot slumping process) by the application of a vacuum pump suction. In this way spring-back deformations and low frequency errors still present on the foil profile after slumping can be corrected. In this paper we present the preliminary results concerning achieved during the first part of the project.

  17. Extension of geometrical-optics approximation to on-axis Gaussian beam scattering. II. By a spheroidal particle with end-on incidence.

    Science.gov (United States)

    Xu, Feng; Ren, Kuan Fang; Cai, Xiaoshu; Shen, Jianqi

    2006-07-10

    On the basis of our previous work on the extension of the geometrical-optics approximation to Gaussian beam scattering by a spherical particle, we present a further extension of the method to the scattering of a transparent or absorbing spheroidal particle with the same symmetric axis as the incident beam. As was done for the spherical particle, the phase shifts of the emerging rays due to focal lines, optical path, and total reflection are carefully considered. The angular position of the geometric rainbow of primary order is theoretically predicted. Compared with our results, the Möbius prediction of the rainbow angle has a discrepancy of less than 0.5 degrees for a spheroidal droplet of aspect radio kappa within 0.95 and 1.05 and less than 2 degrees for kappa within 0.89 and 1.11. The flux ratio index F, which qualitatively indicates the effect of a surface wave, is also studied and found to be dependent on the size, refractive index, and surface curvature of the particle.

  18. Study of intense pulse irradiation effects on silicon targets considered as ground matter for optical detectors; Etude des effets d`irradiations pulsees intenses sur des cibles de silicium considere en tant que materiau de base pour detecteurs optiques

    Energy Technology Data Exchange (ETDEWEB)

    Muller, O

    1994-12-01

    This study aim was centered on morphological and structural alterations induced by laser irradiation on silicon targets considered as ground matter for optical detectors. First we recalled the main high light intensity effects on the condensed matter. Then we presented the experimental aspects. The experimental studies were achieved on two sample types: SiO{sub 2}/Si and Si. Two topics were studied: the defect chronology according to wavelength and pulse length, and the crystalline quality as well as the structure defects of irradiated zones by Raman spectroscopy. Finally, irradiation of Si targets by intense pulsed beams may lead to material fusion. This phenomenon is particularly easy when the material is absorbent, when the pulse is short and when the material is superficially oxidized. (MML). 204 refs., 93 figs., 21 tabs., 1 appendix.

  19. Constellation-X to Generation-X: evolution of large collecting area moderate resolution grazing incidence x-ray telescopes to larger area high-resolution adjustable optics

    Science.gov (United States)

    Reid, Paul B.; Cameron, Robert A.; Cohen, Lester; Elvis, Martin; Gorenstein, Paul; Jerius, Diab; Petre, Robert; Podgorski, William A.; Schwartz, Daniel A.; Zhang, William W.

    2004-10-01

    Large collecting area x-ray telescopes are designed to study the early Universe, trace the evolution of black holes, stars and galaxies, study the chemical evolution of the Universe, and study matter in extreme environments. The Constellation-X mission (Con-X), planned for launch in 2016, will provide ~ 10^4 cm^2 collecting area with 15 arc-sec resolution, with a goal of 5 arc-sec. Future missions require larger collecting area and finer resolution. Generation-X (Gen-X), a NASA Visions Mission, will achieve 100 m^2 effective area at 1 keV and angular resolution of 0.1 arc-sec, half power diameter. We briefly describe the Con-X flowdown of imaging requirements to reflector figure error. To meet requirements beyond Con-X, Gen-X optics will be thinner and more accurately shaped than has ever been accomplished. To meet these challenging goals, we incorporate for the first time active figure control with grazing incidence optics. Piezoelectric material will be deposited in discrete cells directly on the back surface of the optical segments, with the strain directions oriented parallel to the surface. Differential strain between the two layers of the mirror causes localized bending in two directions, enabling local figure control. Adjusting figure on-orbit eases fabrication and metrology. The ability to make changes to mirror figure adds margin by mitigating risk due to launch-induced deformations and/or on-orbit degradation. We flowdown the Gen-X requirements to mirror figure and four telescope designs, and discuss various trades between the designs.

  20. Cholestasis sepsis at neonatology ward and neonatal Intensive Care Unit Cipto Mangunkusumo Hospital 2007 : incidence, mortality rate and associated risk factors

    Directory of Open Access Journals (Sweden)

    Kadim S. Bachtiar

    2008-06-01

    Full Text Available Cholestatic jaundice represents serious pathological condition. Septic-cholestasis is a kind of hepato-cellular cholestasis that occured during or after sepsis caused by biliary flow obstruction. This is a cohort study from February to June 2007 on neonatal sepsis patients at Neonatology ward Department of Child Health Faculty of Medicine University of Indonesia-Cipto Mangunkusumo General National Hospital. Aim of this study is to find out the incidence of intrahepatic cholestasis in neonatal sepsis, associated risk factors, and mortality rate in neonatal cholestasis-sepsis. From 138 neonatal sepsis patients, the incidence of intrahepatic cholestasis is 65.9%. None of the risk factors tested in this study showed statistically significant result. Mortality rate of neonatal cholestasis-sepsis is 52.8%. (Med J Indones 2008; 17: 107-13Keywords: cholestasis intrahepatic, neonatal sepsis, cholestasis sepsis, conjugated hyperbilirubinemia

  1. Severe metabolic or mixed acidemia on intensive care unit admission: incidence, prognosis and administration of buffer therapy. A prospective, multiple-center study.

    Science.gov (United States)

    Jung, Boris; Rimmele, Thomas; Le Goff, Charlotte; Chanques, Gérald; Corne, Philippe; Jonquet, Olivier; Muller, Laurent; Lefrant, Jean-Yves; Guervilly, Christophe; Papazian, Laurent; Allaouchiche, Bernard; Jaber, Samir

    2011-01-01

    In this study, we sought describe the incidence and outcomes of severe metabolic or mixed acidemia in critically ill patients as well as the use of sodium bicarbonate therapy to treat these illnesses. We conducted a prospective, observational, multiple-center study. Consecutive patients who presented with severe acidemia, defined herein as plasma pH below 7.20, were screened. The incidence, sodium bicarbonate prescription and outcomes of either metabolic or mixed severe acidemia were analyzed. Among 2, 550 critically ill patients, 200 (8%) presented with severe acidemia, and 155 (6% of the total admissions) met the inclusion criteria. Almost all patients needed mechanical ventilation and vasopressors during their ICU stay, and 20% of them required renal replacement therapy within the first 24 hours of their ICU stay. Severe metabolic or mixed acidemia was associated with a mortality rate of 57% in the ICU. Delay of acidemia recovery as opposed to initial pH value was associated with increased mortality in the ICU. The type of acidemia did not influence the decision to administer sodium bicarbonate. The incidence of severe metabolic or mixed acidemia in critically ill patients was 6% in the present study, and it was associated with a 57% mortality rate in the ICU. In contradistinction with the initial acid-base parameters, the rapidity of acidemia recovery was an independent risk factor for mortality. Sodium bicarbonate prescription was very heterogeneous between ICUs. Further studies assessing specific treatments may be of interest in this population.

  2. Severe metabolic or mixed acidemia on intensive care unit admission: incidence, prognosis and administration of buffer therapy. a prospective, multiple-center study

    Science.gov (United States)

    2011-01-01

    Introduction In this study, we sought describe the incidence and outcomes of severe metabolic or mixed acidemia in critically ill patients as well as the use of sodium bicarbonate therapy to treat these illnesses. Methods We conducted a prospective, observational, multiple-center study. Consecutive patients who presented with severe acidemia, defined herein as plasma pH below 7.20, were screened. The incidence, sodium bicarbonate prescription and outcomes of either metabolic or mixed severe acidemia were analyzed. Results Among 2, 550 critically ill patients, 200 (8%) presented with severe acidemia, and 155 (6% of the total admissions) met the inclusion criteria. Almost all patients needed mechanical ventilation and vasopressors during their ICU stay, and 20% of them required renal replacement therapy within the first 24 hours of their ICU stay. Severe metabolic or mixed acidemia was associated with a mortality rate of 57% in the ICU. Delay of acidemia recovery as opposed to initial pH value was associated with increased mortality in the ICU. The type of acidemia did not influence the decision to administer sodium bicarbonate. Conclusions The incidence of severe metabolic or mixed acidemia in critically ill patients was 6% in the present study, and it was associated with a 57% mortality rate in the ICU. In contradistinction with the initial acid-base parameters, the rapidity of acidemia recovery was an independent risk factor for mortality. Sodium bicarbonate prescription was very heterogeneous between ICUs. Further studies assessing specific treatments may be of interest in this population. PMID:21995879

  3. Incidence of Secondary Cancer Development After High-Dose Intensity-Modulated Radiotherapy and Image-Guided Brachytherapy for the Treatment of Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Housman, Douglas M.; Pei Xin; Alicikus, Zumre; Magsanoc, Juan Martin; Dauer, Lawrence T.; St Germain, Jean; Yamada, Yoshiya; Kollmeier, Marisa; Cox, Brett; Zhang Zhigang

    2012-01-01

    Purpose: To report the incidence and excess risk of second malignancy (SM) development compared with the general population after external beam radiotherapy (EBRT) and brachytherapy to treat prostate cancer. Methods and Materials: Between 1998 and 2001, 1,310 patients with localized prostate cancer were treated with EBRT (n = 897) or brachytherapy (n = 413). We compared the incidence of SMs in our patients with that of the general population extracted from the National Cancer Institute’s Surveillance, Epidemiology, and End Results data set combined with the 2000 census data. Results: The 10-year likelihood of SM development was 25% after EBRT and 15% after brachytherapy (p = .02). The corresponding 10-year likelihood for in-field SM development in these groups was 4.9% and 1.6% (p = .24). Multivariate analysis showed that EBRT vs. brachytherapy and older age were the only significant predictors for the development of all SMs (p = .037 and p = .030), with a trend for older patients to develop a SM. The increased incidence of SM for EBRT patients was explained by the greater incidence of skin cancer outside the radiation field compared with that after brachytherapy (10.6% and 3.3%, respectively, p = .004). For the EBRT group, the 5- and 10-year mortality rate was 1.96% and 5.1% from out-of field cancer, respectively; for in-field SM, the corresponding mortality rates were 0.1% and 0.7%. Among the brachytherapy group, the 5- and 10-year mortality rate related to out-of field SM was 0.8% and 2.7%, respectively. Our observed SM rates after prostate RT were not significantly different from the cancer incidence rates in the general population. Conclusions: Using modern sophisticated treatment techniques, we report low rates of in-field bladder and rectal SM risks after prostate cancer RT. Furthermore, the likelihood of mortality secondary to a SM was unusual. The greater rate of SM observed with EBRT vs. brachytherapy was related to a small, but significantly increased

  4. Radiative properties of optical board embedded with optical black holes

    International Nuclear Information System (INIS)

    Qiu, J.; Liu, L.H.; Hsu, P.-F.

    2011-01-01

    Unique radiative properties, such as wavelength-selective transmission or absorption, have been intensively studied. Historically, geometries for wavelength-selective of light absorption were developed based on metallic periodical structures, which were only applied in the case of TM wave incidence due to the excitation of surface plasmons. In this paper, we develop an alternative approach to selective wavelength of light absorption (both TE and TM waves), based on an optical board periodical embedded with optical black holes. Numerical work was carried out to study such structure's radiative properties within the wavelength range of 1-100 μm. The electromagnetic wave transmission through such a structure is predicted by solving Maxwell's equations using the finite-difference time-domain (FDTD) method. Spectral absorptance varies with the period of optical black holes. When the incidence wavelength is much larger than the inner core radius, most of the light energy will be transmitted through the inner core. Otherwise, the energy will be mainly absorbed. Numerical results of the radiative properties of the optical board with different incidence wavelengths are also obtained. The effect of the oblique incidence wave is investigated. This study helps us gain a better understanding of the radiative properties of an optical board embedded with optical black holes and develop an alternative approach to selective light absorption.

  5. Incidence and nature of medication errors in neonatal intensive care with strategies to improve safety - A review of the current literature

    NARCIS (Netherlands)

    Chedoe, Indra; Molendijk, Harry A.; Dittrich, Suzanne T. A. M.; Jansman, Frank G. A.; Harting, Johannes W.; Brouwers, Jacobus R. B. J.; Taxis, Katja

    2007-01-01

    Neonates are highly vulnerable to medication errors because of their extensive exposure to medications in the neonatal intensive care unit (NICU), the general lack of evidence on pharmacotherapeutic interventions in neonates and the lack of neonate-specific formulations. We searched PubMed and

  6. Síndrome d'abstinència en cures intensives pediàtriques: incidència i factors de risc: projecte de recerca

    OpenAIRE

    Margelí Voelp, Marta

    2017-01-01

    Critically ill paediatric patients frequently receive prolonged analgesia and sedation to provide pain relief and facilitate intensive care therapies. Although opioids and benzodiazepines have many established benefits, prolonged administration may induce drug tolerance and physiological dependency. Abrupt discontinuation or too rapid tapering of these medications in physically dependent infants may result in iatrogenic withdrawal syndrome (IWS). Despite the fact that IWS has b...

  7. Effect of low-intensity low-dose rate irradiation on the incidence and the development of spontaneous leukosis in AKR mice

    International Nuclear Information System (INIS)

    Burlakova, E.B.; Erokhin, V.N.

    2001-01-01

    Development of spontaneous leukosis in AKR mice is accelerated by irradiation with low doses of 1.2-2.4 cGy and low dose rate 0.06 cGy/day. The leukoses incidence rate increases. Deaths of the animals from leukosis occurs earlier, shortening the average and maximum life-spans of the animals. The dynamics of changes in the mass of organs of the immune systems (thymus and spleen) shows extrema. The moment of reaching the extremum correlates with the maximum rate of animals' deaths [ru

  8. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  9. Retinopathy of prematurity in infants born before 25 weeks gestation in a Korean single neonatal intensive care unit: incidence, natural history and risk factors.

    Science.gov (United States)

    Kong, Mingui; Shin, Dong Hoon; Kim, Sang Jin; Ham, Don Il; Kang, Se Woong; Chang, Yun Sil; Park, Won Soon

    2012-12-01

    As younger preterm infants are able to survive, more extremely preterm infants are at risk of developing retinopathy of prematurity (ROP). To investigate the incidence, progression and risk factors of ROP in extremely preterm infants in Korea, the medical records of infants born before 25 weeks gestation were retrospectively reviewed. The criteria for laser treatment agreed with type 1 ROP as defined by the Early Treatment for Retinopathy of Prematurity study. Of the 121 infants included in the analysis, 119 (98.4%) infants developed any stage ROP, including 78 infants (64.5%) with type 1 ROP. The mean postmenstrual age (PMA) at the onset of any ROP and type 1 ROP were 33.5 and 36.1 weeks, respectively. All but one infant developed type 1 ROP after 31 weeks PMA. Univariate analysis showed that duration of total parenteral nutrition and onset of any ROP (PMA) were associated with the development of type 1 ROP. In conclusion, this study shows high incidence of ROP in extremely preterm infants and suggests that, although current screening protocols are feasible for most preterm infants born before 25 weeks gestation, earlier screening before 31 weeks PMA may be necessary in infants with an unstable clinical course.

  10. The incidence of nosocomial infection in the Intensive Care Unit, Hospital Universiti Kebangsaan Malaysia: ICU-acquired nosocomial infection surveillance program 1998-1999.

    Science.gov (United States)

    Rozaidi, S W; Sukro, J; Dan, A

    2001-06-01

    CU-acquired nosocomial infection (NI) remains one of the major causes of ICU mortality. This study presents the incidence of ICU-acquired nosocomial infection in ICU HUKM for the years 1998 and 1999, as part of the ongoing ICU-acquired nosocomial infection surveillance program. The overall incidence was 23%. The main types of NI was lower respiratory tract infection (15.3%), primary bacteraemia (8.1%), ventilator associated pneumonia (5.4%), urinary tract infection (2.0%), skin infection (1.6%) central venous catheter sepsis (1.2%) and surgical skin infection (0.8%). The overall culture positive nosocomial infection rate was only 12.1%, majority from the lungs (12.6%), blood (7.3%), skin swabs (2.0%), and urine (1.6%). The main gram-negative organism cultured was Acinetobacter sp. (19%) and Staph. aureus (8.5%) was the gram-positive organism. The overall ICU mortality rate was 27.5% of which 60.9% of patients who died were attributed directly to sepsis.

  11. Experimental investigation of saturation effect on pump-to-signal intensity modulation transfer in single-pump phase-insensitive fiber optic parametric amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke

    2013-01-01

    We present an experimental characterization of how signal gain saturation affects the transfer of intensity modulation from the pump to the signal in single-pump, phase-insensitive fiber optic parametric amplifiers (FOPAs). In this work, we demonstrate experimentally for the first time, to our...... knowledge, how gain saturation of a FOPA reduces the noise contribution due to the transfer of pump power fluctuations to the signal. In a particular example, it is shown that the transferred noise is significantly reduced by a factor of 3, while the FOPA gain remains above 10 dB....

  12. Nonlinear optics

    International Nuclear Information System (INIS)

    Boyd, R.W.

    1992-01-01

    Nonlinear optics is the study of the interaction of intense laser light with matter. This book is a textbook on nonlinear optics at the level of a beginning graduate student. The intent of the book is to provide an introduction to the field of nonlinear optics that stresses fundamental concepts and that enables the student to go on to perform independent research in this field. This book covers the areas of nonlinear optics, quantum optics, quantum electronics, laser physics, electrooptics, and modern optics

  13. Image correction in magneto-optical microscopy

    DEFF Research Database (Denmark)

    Paturi, P.; Larsen, B.H.; Jacobsen, B.A.

    2003-01-01

    An image-processing procedure that assures correct determination of the magnetic field distribution of magneto-optical images is presented. The method remedies image faults resulting from sources that are proportional to the incident light intensity, such as different types of defects...

  14. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  15. A high-speed, reconfigurable, channel- and time-tagged photon arrival recording system for intensity-interferometry and quantum optics experiments

    Science.gov (United States)

    Girish, B. S.; Pandey, Deepak; Ramachandran, Hema

    2017-08-01

    We present a compact, inexpensive multichannel module, APODAS (Avalanche Photodiode Output Data Acquisition System), capable of detecting 0.8 billion photons per second and providing real-time recording on a computer hard-disk, of channel- and time-tagged information of the arrival of upto 0.4 billion photons per second. Built around a Virtex-5 Field Programmable Gate Array (FPGA) unit, APODAS offers a temporal resolution of 5 nanoseconds with zero deadtime in data acquisition, utilising an efficient scheme for time and channel tagging and employing Gigabit ethernet for the transfer of data. Analysis tools have been developed on a Linux platform for multi-fold coincidence studies and time-delayed intensity interferometry. As illustrative examples, the second-order intensity correlation function ( g 2) of light from two commonly used sources in quantum optics —a coherent laser source and a dilute atomic vapour emitting spontaneously, constituting a thermal source— are presented. With easy reconfigurability and with no restriction on the total record length, APODAS can be readily used for studies over various time scales. This is demonstrated by using APODAS to reveal Rabi oscillations on nanosecond time scales in the emission of ultracold atoms, on the one hand, and, on the other hand, to measure the second-order correlation function on the millisecond time scales from tailored light sources. The efficient and versatile performance of APODAS promises its utility in diverse fields, like quantum optics, quantum communication, nuclear physics, astrophysics and biology.

  16. Proton polarization in photo-excited aromatic molecule at room temperature enhanced by intense optical source and temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Sakaguchi, S., E-mail: sakaguchi@phys.kyushu-u.ac.jp [Department of Physics, Kyushu University, Fukuoka 812-8581 (Japan); Uesaka, T. [RIKEN Nishina Center, Saitama 351-0198 (Japan); Kawahara, T. [Department of Physics, Toho University, Chiba 274-8510 (Japan); Ogawa, T. [RIKEN Advanced Science Institute, Saitama 351-0198 (Japan); Tang, L. [Center for Nuclear Study, University of Tokyo, Tokyo 113-0001 (Japan); Teranishi, T. [Department of Physics, Kyushu University, Fukuoka 812-8581 (Japan); Urata, Y.; Wada, S. [RIKEN Advanced Science Institute, Saitama 351-0198 (Japan); Wakui, T. [Cyclotron and Radioisotope Center (CYRIC), Tohoku University, Miyagi 980-8578 (Japan)

    2013-12-15

    Highlights: • Proton polarization in p-terphenyl at room-temperature is enhanced by a factor of 3. • Intense laser and temperature control are critically important for high polarization. • Optimization of time structure of laser pulse is effective for further improvement. -- Abstract: Proton polarization at room temperature, produced in a p-terphenyl crystal by using electron population difference in a photo-excited triplet state of pentacene, was enhanced by utilizing an intense laser with an average power of 1.5 W. It was shown that keeping the sample temperature below 300 K is critically important to prevent the rise of the spin–lattice relaxation rate caused by the laser heating. It is also reported that the magnitude of proton polarization strongly depends on the time structure of the laser pulse such as its width and the time interval between them.

  17. Energy levels and far-infrared optical absorption of impurity doped semiconductor nanorings: Intense laser and electric fields effects

    Energy Technology Data Exchange (ETDEWEB)

    Barseghyan, M.G., E-mail: mbarsegh@ysu.am

    2016-11-10

    Highlights: • The electron-impurity interaction on energy levels in nanoring have been investigated. • The electron-impurity interaction on far-infrared absorption have been investigated. • The energy levels are more stable for higher values of electric field. - Abstract: The effects of electron-impurity interaction on energy levels and far-infrared absorption in semiconductor nanoring under the action of intense laser and lateral electric fields have been investigated. Numerical calculations are performed using exact diagonalization technique. It is found that the electron-impurity interaction and external fields change the energy spectrum dramatically, and also have significant influence on the absorption spectrum. Strong dependence on laser field intensity and electric field of lowest energy levels, also supported by the Coulomb interaction with impurity, is clearly revealed.

  18. The additional benefit of residual spraying and insecticide-treated curtains for dengue control over current best practice in Cuba: Evaluation of disease incidence in a cluster randomized trial in a low burden setting with intensive routine control.

    Science.gov (United States)

    Toledo, Maria Eugenia; Vanlerberghe, Veerle; Rosales, Julio Popa; Mirabal, Mayelin; Cabrera, Pedro; Fonseca, Viviana; Gómez Padrón, Tania; Pérez Menzies, Mirtha; Montada, Domingo; Van der Stuyft, Patrick

    2017-11-01

    Aedes control interventions are considered the cornerstone of dengue control programmes, but there is scarce evidence on their effect on disease. We set-up a cluster randomized controlled trial in Santiago de Cuba to evaluate the entomological and epidemiological effectiveness of periodical intra- and peri-domiciliary residual insecticide (deltamethrin) treatment (RIT) and long lasting insecticide treated curtains (ITC). Sixty three clusters (around 250 households each) were randomly allocated to two intervention (RIT and ITC) and one control arm. Routine Aedes control activities (entomological surveillance, source reduction, selective adulticiding, health education) were applied in the whole study area. The outcome measures were clinical dengue case incidence and immature Aedes infestation. Effectiveness of tools was evaluated using a generalized linear regression model with a negative binomial link function. Despite significant reduction in Aedes indices (Rate Ratio (RR) 0.54 (95%CI 0.32-0.89) in the first month after RIT, the effect faded out over time and dengue incidence was not reduced. Overall, in this setting there was no protective effect of RIT or ITC over routine in the 17months intervention period, with for house index RR of 1.16 (95%CI 0.96-1.40) and 1.25 (95%CI 1.03-1.50) and for dengue incidence RR of 1.43 (95%CI 1.08-1.90) and 0.96 (95%CI 0.72-1.28) respectively. The monthly dengue incidence rate (IR) at cluster level was best explained by epidemic periods (Incidence Rate Ratio (IRR) 5.50 (95%CI 4.14-7.31)), the IR in bordering houseblocks (IRR 1.03 (95%CI 1.02-1.04)) and the IR pre-intervention (IRR 1.02 (95%CI 1.00-1.04)). Adding RIT to an intensive routine Aedes control programme has a transient effect on the already moderate low entomological infestation levels, while ITC did not have any effect. For both interventions, we didn't evidence impact on disease incidence. Further studies are needed to evaluate impact in settings with high Aedes

  19. A series approximation model for optical light transport and output intensity field distribution in large aspect ratio cylindrical scintillation crystals

    Energy Technology Data Exchange (ETDEWEB)

    Tobias, Benjamin John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-09

    A series approximation has been derived for the transport of optical photons within a cylindrically symmetric light pipe and applied to the task of evaluating both the origin and angular distribution of light reaching the output plane. This analytic expression finds particular utility in first-pass photonic design applications since it may be evaluated at a very modest computational cost and is readily parameterized for relevant design constraints. It has been applied toward quantitative exploration of various scintillation crystal preparations and their impact on both quantum efficiency and noise, reproducing sensible dependencies and providing physical justification for certain gamma ray camera design choices.

  20. Incidence of hypochloremic metabolic alkalosis in dogs and cats with and without nasogastric tubes over a period of up to 36 hours in the intensive care unit.

    Science.gov (United States)

    Chih, Annie; Rudloff, Elke; Waldner, Cheryl; Linklater, Andrew K J

    2018-05-01

    To evaluate the incidence of hypochloremic metabolic alkalosis (HCMA) in dogs and cats in the ICU that had intermittent nasogastric tube (NGT) aspiration for up to 36 hours. Prospective cohort study (December 2013 to October 2014). Privately owned emergency and referral teaching hospital. Forty-nine client-owned dogs and 16 client-owned cats. Patients wherein NGT placement was recommended and client consent was obtained were included in the interventional group. Those with an NGT placed (NGT group) had the NGT aspirated every 4 hours. Patients for whom placement of a NGT was declined by the owner served as a reference group (NoNGT). Venous blood gas and electrolyte values were obtained every 12 hours. Thirty-five dogs and cats had an NGT placed. Thirty dogs and cats did not have an NGT placed. The serum venous blood gas and electrolyte changes were compared over time within the NGT group and between the NGT and NoNGT groups. No cases developed HCMA. In the NGT group, blood pH increased over time. There was no significant difference between the NGT and the NoNGT group in the average value of pH, HCO 3 - , base excess, chloride, or corrected chloride. Serum venous blood gas, chloride, and corrected chloride changes were not associated with the volumes of gastric fluid aspirated over time. In this small population of dogs and cats, intermittent NGT aspiration was not associated with the development of HCMA over a period of up to 36 hours after NGT placement. © Veterinary Emergency and Critical Care Society 2018.

  1. Combined effects of intense laser field, electric and magnetic fields on the nonlinear optical properties of the step-like quantum well

    Energy Technology Data Exchange (ETDEWEB)

    Kasapoglu, E., E-mail: ekasap@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia-UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mora-Ramos, M.E. [Facultad de Ciencias, Universidad Autónoma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Restrepo, R.L. [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia-UdeA, Calle 70 No. 52-21, Medellín (Colombia); Escuela de Ingeniería de Antioquia-EIA, Medellín (Colombia); Ungan, F.; Yesilgul, U.; Sari, H. [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Sökmen, I. [Department of Physics, Dokuz Eylül University, 35160 Buca, İzmir (Turkey)

    2015-03-15

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change for transition between two lower-lying electronic levels in the step-like GaAs/Ga{sub 1−x}Al{sub x}As quantum well under external electric and magnetic fields are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass and parabolic band approximations. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the well dimensions and the effects of external fields. By changing the intensities of the electric, magnetic and non-resonant intense laser fields together with the well dimensions, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • Augmentation of laser-field results in red shift in total AC spectra. • Magnetic field induces a blue-shift in the resonant peak. • Resonant peak position shifts to red with effect of electric field. • Resonant peak of total AC shifts to the higher photon energies with increasing well width.

  2. Combined effects of intense laser field, electric and magnetic fields on the nonlinear optical properties of the step-like quantum well

    International Nuclear Information System (INIS)

    Kasapoglu, E.; Duque, C.A.; Mora-Ramos, M.E.; Restrepo, R.L.; Ungan, F.; Yesilgul, U.; Sari, H.; Sökmen, I.

    2015-01-01

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change for transition between two lower-lying electronic levels in the step-like GaAs/Ga 1−x Al x As quantum well under external electric and magnetic fields are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass and parabolic band approximations. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the well dimensions and the effects of external fields. By changing the intensities of the electric, magnetic and non-resonant intense laser fields together with the well dimensions, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • Augmentation of laser-field results in red shift in total AC spectra. • Magnetic field induces a blue-shift in the resonant peak. • Resonant peak position shifts to red with effect of electric field. • Resonant peak of total AC shifts to the higher photon energies with increasing well width

  3. Using Multivariate Regression Model with Least Absolute Shrinkage and Selection Operator (LASSO) to Predict the Incidence of Xerostomia after Intensity-Modulated Radiotherapy for Head and Neck Cancer

    Science.gov (United States)

    Ting, Hui-Min; Chang, Liyun; Huang, Yu-Jie; Wu, Jia-Ming; Wang, Hung-Yu; Horng, Mong-Fong; Chang, Chun-Ming; Lan, Jen-Hong; Huang, Ya-Yu; Fang, Fu-Min; Leung, Stephen Wan

    2014-01-01

    Purpose The aim of this study was to develop a multivariate logistic regression model with least absolute shrinkage and selection operator (LASSO) to make valid predictions about the incidence of moderate-to-severe patient-rated xerostomia among head and neck cancer (HNC) patients treated with IMRT. Methods and Materials Quality of life questionnaire datasets from 206 patients with HNC were analyzed. The European Organization for Research and Treatment of Cancer QLQ-H&N35 and QLQ-C30 questionnaires were used as the endpoint evaluation. The primary endpoint (grade 3+ xerostomia) was defined as moderate-to-severe xerostomia at 3 (XER3m) and 12 months (XER12m) after the completion of IMRT. Normal tissue complication probability (NTCP) models were developed. The optimal and suboptimal numbers of prognostic factors for a multivariate logistic regression model were determined using the LASSO with bootstrapping technique. Statistical analysis was performed using the scaled Brier score, Nagelkerke R2, chi-squared test, Omnibus, Hosmer-Lemeshow test, and the AUC. Results Eight prognostic factors were selected by LASSO for the 3-month time point: Dmean-c, Dmean-i, age, financial status, T stage, AJCC stage, smoking, and education. Nine prognostic factors were selected for the 12-month time point: Dmean-i, education, Dmean-c, smoking, T stage, baseline xerostomia, alcohol abuse, family history, and node classification. In the selection of the suboptimal number of prognostic factors by LASSO, three suboptimal prognostic factors were fine-tuned by Hosmer-Lemeshow test and AUC, i.e., Dmean-c, Dmean-i, and age for the 3-month time point. Five suboptimal prognostic factors were also selected for the 12-month time point, i.e., Dmean-i, education, Dmean-c, smoking, and T stage. The overall performance for both time points of the NTCP model in terms of scaled Brier score, Omnibus, and Nagelkerke R2 was satisfactory and corresponded well with the expected values. Conclusions

  4. Incidence, Microbiological Profile and Risk Factors of Healthcare-Associated Infections in Intensive Care Units: A 10 Year Observation in a Provincial Hospital in Southern Poland

    Science.gov (United States)

    Kołpa, Małgorzata; Wałaszek, Marta; Gniadek, Agnieszka; Wolak, Zdzisław; Dobroś, Wiesław

    2018-01-01

    Healthcare-associated infections (HAIs) occurring in patients treated in an intensive care unit (ICU) are serious complications in the treatment process. Aetiological factors of these infections can have an impact on treatment effects, treatment duration and mortality. The aim of the study was to determine the prevalence and microbiological profile of HAIs in patients hospitalized in an ICU over a span of 10 years. The active surveillance method was used to detect HAIs in adult patients who spent over 48 h in a general ICU ward located in southern Poland between 2007 and 2016. The study was conducted in compliance with the methodology recommended by the Healthcare-associated Infections Surveillance Network (HAI-Net) of the European Centre for Disease Prevention and Control (ECDC). During the 10 years of the study, 1849 patients hospitalized in an ICU for a total of 17,599 days acquired 510 with overall HAIs rates of 27.6% and 29.0% infections per 1000 ICU days. Intubation-associated pneumonia (IAP) posed the greatest risk (15.2 per 1000 ventilator days), followed by CLA-BSI (8.0 per 1000 catheter days) and CA-UTI (3.0 per 1000 catheter days). The most common isolated microorganism was Acinetobacter baumannii (25%) followed by Coagulaase-negativ staphylococci (15%), Escherichia coli (9%), Pseudomonas aeruginosa (8%), Klebsiella pneumoniae (7%), Candida albicans (6%). Acinetobacter baumannii in 87% and were classified as extensive-drug resistant (XDR). In summary, in ICU patients pneumonia and bloodstream infections were the most frequently found. Acinetobacter baumannii strains were most often isolated from clinical materials taken from HAI patients and showed resistance to many groups of antibiotics. A trend of increasing resistance of Acinetobacter baumannii to carbapenems was observed. PMID:29324651

  5. DeVelopment of the high-intensity polarized H- source with proton charge exchange on sodium optically oriented atoms

    International Nuclear Information System (INIS)

    Zelenskij, A.N.; Kokhanovskij, S.A.

    1982-01-01

    The results of experimental study on the source of polarized H - ions at polarized electron capture by proton from optically oriented sodium atoms are presented. Circular-polarized dye laser radiation with lamp pumping is used for polarization of highly dense sodium vapors in the pulsed mode. A facility for polarization measurement in the ion source is described. Dependence of the counting rate of metastables for the right and left circular radiation polarization in respect to wave length is presented. The results of measuring the degree of polarization under change of sodium density are revealed. The measurements have disclosed that obtaining of high polarization degree at 20-30% charge exchange effectiveness is possible but large radiation power is required. Use of a dense charge exchange target provides high effectiveness of hte whole polarization process. Yield of polarized H - ions can approach 10 μA/1 mA of the initial proton current

  6. Theoretical study for aerial image intensity in resist in high numerical aperture projection optics and experimental verification with one-dimensional patterns

    Science.gov (United States)

    Shibuya, Masato; Takada, Akira; Nakashima, Toshiharu

    2016-04-01

    In optical lithography, high-performance exposure tools are indispensable to obtain not only fine patterns but also preciseness in pattern width. Since an accurate theoretical method is necessary to predict these values, some pioneer and valuable studies have been proposed. However, there might be some ambiguity or lack of consensus regarding the treatment of diffraction by object, incoming inclination factor onto image plane in scalar imaging theory, and paradoxical phenomenon of the inclined entrance plane wave onto image in vector imaging theory. We have reconsidered imaging theory in detail and also phenomenologically resolved the paradox. By comparing theoretical aerial image intensity with experimental pattern width for one-dimensional pattern, we have validated our theoretical consideration.

  7. Intense blue upconversion emission and intrinsic optical bistability in Tm3+/Yb3+/Zn2+ tridoped YVO4 phosphors

    Science.gov (United States)

    Yadav, Manglesh; Mondal, Manisha; Mukhopadhyay, Lakshmi; Rai, Vineet Kumar

    2018-04-01

    Tm3+/Yb3+/Zn2+:yttrium metavanadate (YVO4) phosphors prepared through chemical coprecipitation and the solid state reaction method have been structurally characterized by an x-ray diffraction (XRD) study. Photoluminescence study of the developed phosphors under ultraviolet (UV) and near infrared (NIR) excitation has been performed. The excitation spectrum of the tetragonal zircon type YVO4 phosphors corresponding to the emission at ˜476 nm exhibits a broad excitation peak in the 250-350 nm region, which is due to charge distribution in the {{{{VO}}}4}3- group. Under 980 nm CW diode laser excitation, enhancements of about ˜3000 times and ˜40 times have been observed for the blue band in the tridoped Tm3+Yb3+Zn2+:YVO4 phosphors compared to those of the Tm3+:YVO4 singly and Tm3+/Yb3+:YVO4 codoped phosphors, respectively. A downconversion (DC) emission study shows an enhancement of about ˜50 times for the blue band in the tridoped phosphors compared to that of the singly doped phosphors. Optical bistability (OB) behavior of the developed phosphors has been also investigated upon 980 nm excitation. The calculated Commission Internationale de l’Éclairage (CIE) color coordinates lie in the blue region with 96.5% color purity under 980 nm excitation, having a color temperature of ˜3400 K. Our observations show that the developed phosphors may be suitably used in dual mode luminescence spectroscopy, display devices, and UV LED chips.

  8. Cranial nerve threshold for thermal injury induced by MRI-guided high-intensity focused ultrasound (MRgHIFU): preliminary results on an optic nerve model.

    Science.gov (United States)

    Harnof, Sagi; Zibly, Zion; Cohen, Zvi; Shaw, Andrew; Schlaff, Cody; Kassel, Neal F

    2013-04-01

    Future clinical applications of magnetic resonance imaging-guided high-intensity focused ultrasound (MRgHIFU) are moving toward the management of different intracranial pathologies. We sought to validate the production, safety, and efficacy of thermal injury to cranial nerves generated by MRgHIFU. In this study, five female domestic pigs underwent a standard bifrontal craniectomy under general anesthesia. Treatment was then given using an MRgHIFU system to induce hyperthermic ablative sonication (6 to 10 s; 50 to 2000 J.) Histological analyses were done to confirm nerve damage; temperature measured on the optic nerve was approximately 53.4°C (range: 39°C to 70°C.) Histology demonstrated a clear definition between a necrotic, transitional zone, and normal tissue. MRgHIFU induces targeted thermal injury to nervous tissue within a specific threshold of 50°C to 60°C with the tissue near the sonication center yielding the greatest effect; adjacent tissue showed minimal changes. Additional studies utilizing this technology are required to further establish accurate threshold parameters for optic nerve thermo-ablation.

  9. Intense source of cold cesium atoms based on a two-dimensional magneto–optical trap with independent axial cooling and pushing

    International Nuclear Information System (INIS)

    Huang Jia-Qiang; Wu Chen-Fei; Wang Li-Jun; Yan Xue-Shu; Zhang Jian-Wei

    2016-01-01

    We report our studies on an intense source of cold cesium atoms based on a two-dimensional (2D) magneto–optical trap (MOT) with independent axial cooling and pushing. The new-designed source, proposed as 2D-HP MOT, uses hollow laser beams for axial cooling and a thin pushing laser beam to extract a cold atomic beam. With the independent pushing beam, the atomic flux can be substantially optimized. The total atomic flux maximum obtained in the 2D-HP MOT is 4.02 × 10 10 atoms/s, increased by 60 percent compared to the traditional 2D + MOT in our experiment. Moreover, with the pushing power 10 μW and detuning 0 Γ , the 2D-HP MOT can generate a rather intense atomic beam with the concomitant light shift suppressed by a factor of 20. The axial velocity distribution of the cold cesium beams centers at 6.8 m/s with an FMHW of about 2.8 m/s. The dependences of the atomic flux on the pushing power and detuning are studied in detail. The experimental results are in good agreement with the theoretical model. (paper)

  10. Microstructure-mediated Optical Effects in Southern African Snakes

    Directory of Open Access Journals (Sweden)

    Singh Ishan

    2017-01-01

    Full Text Available The scales of the African Viper Bitis arietans were tested for optical effects. Spectral intensity was recorded at incident angles over the visible spectrum for dark, pale, and ventral scale regions. The lowest spectral intensity recordings were associated with scales which have the greatest level of micro-structuring. Our results indicate that scale appearance in B. arietans is a product of microstructure-mediated optical effects. The optical effect may play a role in improving the ecological performance of the snake in its natural environment.

  11. The role of low light intensity: A step towards understanding the connection between light, optic/lens and photovoltaic behavior for Sb2S3 thin-film solar cells

    Science.gov (United States)

    Lojpur, Vesna; Mitrić, Miodrag; Validžić, Ivana Lj

    2018-05-01

    We report here an optic/lens system that we used so far, for cooling the surface of solar cells, the reduction of light intensity and the change of light distribution that reaches the surface of the solar cell. The objective was to improve photovoltaic characteristics under very low light illumination, as well as to understand the connection between light, optic/lens and photovoltaic behavior for Sb2S3 thin-film solar cells. It was found that for all so far designed thin-film solar cells made and based on the synthesized Sb2S3, optics/lens system causes an increase in open circuit voltage (VOC) and short circuit current (ISC) and thus the efficiencies of made solar devices. Values of energy gaps for the thin-films made devices were in the range from 1.4 to 2 eV. Improvements of the photovoltaic response of the designed devices are found to be better at the lower light intensity (5% sun), than at higher intensities of light. For the same intensity of light used optic/lens improves the efficiency of the devices, by changing the light distribution. Other processes that are related to the optics/lens system, leading to an increase in ISC and VOC and consequently to an increase in efficiencies of the designed devices, are investigated.

  12. Chemical and optical properties of atmospheric aerosols in Phimai, Thailand by intensive surface measurements and satellite data analysis

    Science.gov (United States)

    Tsuruta, H.; Thana, B.; Takamura, T.; Hashimoto, M.; Yabuki, M.; Oikawa, E.; Nakajima, T.

    2013-12-01

    Atmospheric aerosols were measured at the Observatory of Atmospheric Research, in Phimai, Thailand, a key station of SKYNET, during 2006-2008. In the surface measurement, mass concentrations and major chemical components in fine and coarse aerosols were analyzed, and the optical properties such as AOT and SSA were measured by skyradiometer. Analysis of MODIS and CALIPSO satellite data was made for wild fire activities and aerosol distribution, respectively. In this paper, the following topics are summarized. The surface wind pattern in dry season was divided into the three periods as follows; D1 (Oct.-Nov.) with northeasterly monsoon, D3 (middle March-April) with southerly wind, and D2 (Dec.-early March) with a transit stage between D1 and D3. Wet season in southwesterly monsoon was from May to September. The concentration ratio of BC/nss-SO4 showed that the dominant PM2.5 aerosols in D1 were due to long-range transport of air pollutants emitted from urban/industrial area of east Asia. In contrast, most of aerosols in D3 were derived from biomass burning in Indochina, because the activity of biomass burning was highest in the latter D2 and early D3 period, by the analysis of the fire database in MODIS and of BC/nss-SO4. The mass concentration in PM2.5 showed a clear seasonal variation with the maximum in D2. On the contrary, AOT showed the maximum in D3, and which could be attributed to an increase in the vertical thickness of high aerosol concentration in the boundary layer by the CALIOP data analysis. Dust particles in D1 were directly transported from east Asia, and re-suspension of soil dusts was dominant in D2 because the surface soil became dry. In D3, soil dusts were re-suspended with the thermal plume caused by biomass burning. In contrast, high dust particles measured in the wet season was due to long range transport of dust aerosols from western desert area by the CALIOP data analysis.

  13. Mapping rice extent map with crop intensity in south China through integration of optical and microwave images based on google earth engine

    Science.gov (United States)

    Zhang, X.; Wu, B.; Zhang, M.; Zeng, H.

    2017-12-01

    Rice is one of the main staple foods in East Asia and Southeast Asia, which has occupied more than half of the world's population with 11% of cultivated land. Study on rice can provide direct or indirect information on food security and water source management. Remote sensing has proven to be the most effective method to monitoring the cropland in large scale by using temporary and spectral information. There are two main kinds of satellite have been used to mapping rice including microwave and optical. Rice, as the main crop of paddy fields, the main feature different from other crops is flooding phenomenon at planning stage (Figure 1). Microwave satellites can penetrate through clouds and efficiency on monitoring flooding phenomenon. Meanwhile, the vegetation index based on optical satellite can well distinguish rice from other vegetation. Google Earth Engine is a cloud-based platform that makes it easy to access high-performance computing resources for processing very large geospatial datasets. Google has collected large number of remote sensing satellite data around the world, which providing researchers with the possibility of doing application by using multi-source remote sensing data in a large area. In this work, we map rice planting area in south China through integration of Landsat-8 OLI, Sentienl-2, and Sentinel-1 Synthetic Aperture Radar (SAR) images. The flowchart is shown in figure 2. First, a threshold method the VH polarized backscatter from SAR sensor and vegetation index including normalized difference vegetation index (NDVI) and enhanced vegetation index (EVI) from optical sensor were used the classify the rice extent map. The forest and water surface extent map provided by earth engine were used to mask forest and water. To overcome the problem of the "salt and pepper effect" by Pixel-based classification when the spatial resolution increased, we segment the optical image and use the pixel- based classification results to merge the object

  14. Light distribution analysis of optical fibre probe-based near-field optical tweezers using FDTD

    Energy Technology Data Exchange (ETDEWEB)

    Liu, B H; Yang, L J; Wang, Y [School of Mechanical and Electrical Engineering, Harbin Institute of Technology, Heilongjiang, Harbin, 150001 (China)], E-mail: richelaw@163.com

    2009-09-01

    Optical fibre probe-based near-field optical tweezers overcomes the diffraction limit of conventional optical tweezers, utilizing strong mechanical forces and torque associated with highly enhanced electric fields to trap and manipulate nano-scale particles. Near-field evanescent wave generated at optical fibre probe decays rapidly with the distance that results a significant reduced trapping volume, thus it is necessary to analyze the near-field distribution of optical fibre probe. The finite difference time domain (FDTD) method is applied to characterize the near-field distribution of optical fibre probe. In terms of the distribution patterns, depolarization and polarization, the near-field distributions in longitudinal sections and cross-sections of tapered metal-coated optical fibre probe are calculated. The calculation results reveal that the incident polarized wave becomes depolarized after exiting from the nano-scale aperture of probe. The near-field distribution of the probe is unsymmetrical, and the near-field distribution in the cross-section vertical to the incident polarized wave is different from that in the cross-section parallel to the incident polarized wave. Moreover, the polarization of incident wave has a great impact on the light intensity distribution.

  15. The impact of an education program on hand hygiene compliance and nosocomial infection incidence in an urban neonatal intensive care unit: an intervention study with before and after comparison.

    Science.gov (United States)

    Helder, Onno K; Brug, Johannes; Looman, Caspar W N; van Goudoever, Johannes B; Kornelisse, René F

    2010-10-01

    Nosocomial bloodstream infections are a major cause of morbidity and mortality in neonatal intensive care units. Appropriate hand hygiene is singled out as the most important measure in preventing these infections. However, hand hygiene compliance among healthcare professionals remains low despite the well-known effect on infection reduction. We studied the effectiveness of a hand hygiene education program on the incidence of nosocomial bloodstream infections. Observational study with two pretests and two posttest measurements and interrupted time series analysis. A 27 bed level IIID neonatal intensive care unit in a teaching hospital in the Netherlands. Healthcare professionals who had physical contact with very low birth weight (VLBW) infants. The study was conducted during a period of 4 years. Medical and nursing staff followed a problem-based education program on hand hygiene. Hand hygiene practices before and after the education program were compared by guided observations. The incidence of nosocomial infections in VLBW infants was compared. In addition, numbers of nosocomial bloodstream infections per day-at-risk in very low birth weight infants were analyzed by a segmented loglinear regression analysis. During 1201 observations hand hygiene compliance before patient contact increased from 65% to 88% (pinfections and the infection rate per 1000 patient days (relative risk reduction) before and after the education program on hand hygiene intervention decreased from 44.5% to 36.1% (18.9%, p=0.03) and from 17.3% to 13.5% (22.0%, p=0.03), respectively. At the baseline the nosocomial bloodstream infections per day-at-risk decreased by +0.07% (95% CI -1.41 to +1.60) per month and decreased with -1.25% (95% CI -4.67 to +2.44) after the intervention (p=0.51). The level of instant change was -14.8% (p=0.48). The results are consistent with relevant improvement of hand hygiene practices among healthcare professionals due to an education program. Improved hand hygiene

  16. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  17. Cavity Ring-Down Measurement of Aerosol Optical Properties During the Asian Dust Above Monterey Experiment and DOE Aerosol Intensive Operating Period

    Science.gov (United States)

    Ricci, K.; Strawa, A. W.; Provencal, R.; Castaneda, R.; Bucholtz, A.; Schmid, B.

    2004-01-01

    Large uncertainties in the effects of aerosols on climate require improved in-situ measurements of extinction coefficient and single-scattering albedo. This paper describes preliminary results from Cadenza, a new continuous wave cavity ring-down (CW-CRD) instrument designed to address these uncertainties. Cadenza measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. In the past year Cadenza was deployed in the Asian Dust Above Monterey (ADAM) and DOE Aerosol Intensive Operating Period (IOP) field projects. During these flights Cadenza produced measurements of aerosol extinction in the range from 0.2 to 300/Mm with an estimated precision of 0.1/Mm for 1550 nm light and 0.2/Mm for 675 nm light. Cadenza data from the ADAM and Aerosol IOP missions compared favorably with data from the other instruments aboard the CIRPAS Twin Otter aircraft and participating in those projects. We present comparisons between the Cadenza measurements and those from a TSI nephelometer, Particle Soot Absorption Photometer (PSAP), and the AATS 14 sun-photometer. Measurements of the optical properties of smoke and dust plumes sampled during these campaigns are presented and estimates of heating rates due to these plumes are made.

  18. Real-time incident detection using social media data.

    Science.gov (United States)

    2016-05-09

    The effectiveness of traditional incident detection is often limited by sparse sensor coverage, and reporting incidents to emergency response systems : is labor-intensive. This research project mines tweet texts to extract incident information on bot...

  19. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  20. Incidents analysis

    Energy Technology Data Exchange (ETDEWEB)

    Francois, P

    1997-12-31

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs.

  1. Comparison of intensity-modulated radiotherapy and volumetric-modulated arc therapy dose measurement for head and neck cancer using optical stimulated luminescence dosimeter

    International Nuclear Information System (INIS)

    Lai, Lu-Han; Chuang, Keh-Shih; Lin, Hsin-Hon; Liu, Yi-Chi; Kuo, Chiung-Wen; Lin, Jao-Perng

    2017-01-01

    The in-vivo dose distributions of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), a newly developed technique, for head and neck cancer have been investigated for several years. The present study used a head-and-neck RANDO phantom to simulate the clinical conditions of nasopharyngeal carcinoma and compare the radiation doses between VMAT and IMRT. Three types of planning target volume (PTV) profiles were targeted by reducing the PTV surface margin by 0, 3, and 5 mm. An optically stimulated luminescence dosimeter was used to measure the surface doses. The results revealed that VMAT provided on average 16.8–13.8% lower surface doses within the PTV target areas than IMRT. When the PTV margin was reduced by 0 mm, the surface doses for IMRT reached their maximum value, accounting for 75.1% of its prescribed dose (Dp); however, the Dp value of VMAT was only 61.1%. When the PTV margin was reduced by 3 or 5 mm, the surface doses decreased considerably. The observed surface doses were insufficient when the tumours invaded the body surface; however, VMAT exerted larger skin-sparing effects than IMRT when the tumours away from the skin. These results suggest that the skin doses for these two techniques are insufficient for surface tumours. Notably, VMAT can provide lower skin doses for deep tumours. - Highlights: • The surface doses of NPC patients are compared between VMAT and IMRT. • VMAT exerts lower skin dose than IMRT for deep tumours. • The surface tumour coverage is insufficient for VMAT and IMRT.

  2. The potential of high intensity focused ultrasound (HIFU) combine phase-sensitive optical coherence tomography (PhS-OCT) for diseases diagnosis, treatment and monitoring

    Science.gov (United States)

    Zhou, Kanheng; Wang, Yan; Feng, Kairui; Li, Chunhui; Huang, Zhihong

    2018-02-01

    HIFU is a truly noninvasive, acoustic therapeutic technique that utilizes high intensity acoustic field in the focus to kill the targeted tissue for disease treatment purpose. The mechanical properties of targeted tissue changes before and after treatment, and this change can be accurately detected by shear wave elastography. Hence, shear wave elastography is usually used for monitoring HIFU treatment asynchronously. To improve the low spatial resolution in ultrasound shear wave elastography, and to perform diseases diagnosis, treatment and monitoring in the same system, a new setup that combines HIFU and PhS-OCT system was proposed in this study. This proposed setup could do 1) HIFU treatment when the transducer works at high energy level, 2) ultrasound induced shear wave optical coherence elastography for HIFU treatment asynchronous monitoring when the transducer works at low energy level. Ex-vivo bovine liver tissue was treated at the same energy level for different time (0s, 1s, 5s, 9s) in this research. Elastography was performed on the lesion area of the sample after HIFU treatment, and the elastogram was reconstructed by the time of flight time method. The elastogram results clearly show the boundary of HIFU lesion area and surrounding normal tissue, even for 1s treatment time. And the average elasticity of the lesion grows linearly as the treatment time increases. Combined with OCT needle probe, the proposed method has a large potential not only to be used for superficial diseases treatment, but also to be used for high-precision-demanded diseases treatment, e.g. nervous disease treatment.

  3. Intensity Map of the Repeating Fast Radio Burst FRB 121102 Host Galaxy from Subaru/Kyoto 3DII AO-assisted Optical Integral-field Spectroscopy

    Science.gov (United States)

    Kokubo, Mitsuru; Mitsuda, Kazuma; Sugai, Hajime; Ozaki, Shinobu; Minowa, Yosuke; Hattori, Takashi; Hayano, Yutaka; Matsubayashi, Kazuya; Shimono, Atsushi; Sako, Shigeyuki; Doi, Mamoru

    2017-08-01

    We present the Hα intensity map of the host galaxy of the repeating fast radio burst FRB 121102 at a redshift of z = 0.193 obtained with the AO-assisted Kyoto 3DII optical integral-field unit mounted on the 8.2 m Subaru Telescope. We detected a compact Hα-emitting (I.e., star-forming) region in the galaxy, which has a much smaller angular size (GMOS z\\prime -band image (≃ 1\\buildrel{\\prime\\prime}\\over{.} 4 (4.6 kpc) at FWHM with ellipticity b/a=0.45). The spatial offset between the centroid of the Hα emission region and the position of the radio bursts is 0\\buildrel{\\prime\\prime}\\over{.} 08+/- 0\\buildrel{\\prime\\prime}\\over{.} 02 (0.26 ± 0.07 kpc), indicating that FRB 121102 is located within the star-forming region. This close spatial association of FRB 121102 with the star-forming region is consistent with expectations from young pulsar/magnetar models for FRB 121102, and it also suggests that the observed Hα emission region can make a major dispersion measure (DM) contribution to the host galaxy DM component of FRB 121102. Nevertheless, the largest possible value of the DM contribution from the Hα emission region inferred from our observations still requires a significant amount of ionized baryons in intergalactic medium (IGM; the so-called “missing” baryons) as the DM source of FRB 121102, and we obtain a 90% confidence level lower limit on the cosmic baryon density in the IGM in the low-redshift universe as {{{Ω }}}{IGM}> 0.012. Based on data collected at Subaru Telescope, which is operated by the National Astronomical Observatory of Japan.

  4. Incidência de insuficiência renal aguda na Unidade de Terapia Intensiva Neonatal de um hospital paulista Incidencia de insuficiencia renal crónica aguda en la Unidad de Cuidados Intensivos Neonatal de un hospital de Sao Paulo Incidence of acute renal failure in the Neonatal Intensive Care Unit of a hospital in São Paulo

    Directory of Open Access Journals (Sweden)

    Renato Ribeiro Nogueira Ferraz

    2009-01-01

    .OBJECTIVES: To describe the incidence of acute renal failure (ARF in the neonatal intensive care unit (NICU of a hospital in São Paulo and to verify the use of the "risk of renal failure, injury to the kidney, failure of kidney function, loss of kidney function and end-stage renal failure (RIFLE" classification for the allocation of the neonates. METHODS: Review of medical records of neonates from April 4 to April 25, 2008. RESULTS: Of the 19 admissions in the NICU, 10% were diagnosed as ARF according to the RIFLE classification. The neonates diagnosed with ARF were referred to the dialysis service. CONCLUSION: Although this study had a very small sample size, the findings indicate that ARF represents 10% of the primary diagnosis among our sample of neonates admitted to the NICU. Large and longer studies are necessary to evaluate the incidence of ARF in the NICU.

  5. Self-Induced Backaction Optical Pulling Force

    Science.gov (United States)

    Zhu, Tongtong; Cao, Yongyin; Wang, Lin; Nie, Zhongquan; Cao, Tun; Sun, Fangkui; Jiang, Zehui; Nieto-Vesperinas, Manuel; Liu, Yongmin; Qiu, Cheng-Wei; Ding, Weiqiang

    2018-03-01

    We achieve long-range and continuous optical pulling in a periodic photonic crystal background, which supports a unique Bloch mode with the self-collimation effect. Most interestingly, the pulling force reported here is mainly contributed by the intensity gradient force originating from the self-induced backaction of the object to the self-collimation mode. This force is sharply distinguished from the widely held conception of optical tractor beams based on the scattering force. Also, this pulling force is insensitive to the angle of incidence and can pull multiple objects simultaneously.

  6. Reflective optics

    CERN Document Server

    Korsch, Dietrich

    1991-01-01

    This is the first book dedicated exclusively to all-reflective imaging systems. It is a teaching tool as well as a practical design tool for anyone who specializes in optics, particularly for those interested in telescopes, infrared, and grazing-incidence systems. The first part of the book describes a unified geometric optical theory of all-reflective imaging systems (from near-normal to grazing incidence) developed from basic principles. The second part discusses correction methods and a multitude of closed-form solutions of well-corrected systems, supplemented with many conventional and unc

  7. Effect of intense high-frequency laser field on the linear and nonlinear intersubband optical absorption coefficients and refractive index changes in a parabolic quantum well under the applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Yesilgul, U., E-mail: uyesilgul@cumhuriyet.edu.tr [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Ungan, F. [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Sakiroglu, S. [Dokuz Eylül University, Physics Department, 35160 Buca, İzmir (Turkey); Mora-Ramos, M.E. [Facultad de Ciencias Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, C.P. 62209 Cuernavaca, Morelos (Mexico); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Kasapoglu, E.; Sarı, H. [Cumhuriyet University, Physics Department, 58140 Sivas (Turkey); Sökmen, I. [Dokuz Eylül University, Physics Department, 35160 Buca, İzmir (Turkey)

    2014-01-15

    The effects of the intense high-frequency laser field on the optical absorption coefficients and the refractive index changes in a GaAs/GaAlAs parabolic quantum well under the applied electric field have been investigated theoretically. The electron energy levels and the envelope wave functions of the parabolic quantum well are calculated within the effective mass approximation. Analytical expressions for optical properties are obtained using the compact density-matrix approach. The numerical results show that the intense high-frequency laser field has a large effect on the optical characteristics of these structures. Also we can observe that the refractive index and absorption coefficient changes are very sensitive to the electric field in large dimension wells. Thus, this result gives a new degree of freedom in the optoelectronic device applications. -- Highlights: • ILF has a large effect on the optical properties of parabolic quantum wells. • The total absorption coefficients increase as the ILF increases. • The RICs increase as the ILF increases.

  8. The effect of excitation intensity variation and silver nanoparticle codoping on nonlinear optical properties of mixed tellurite and zinc oxide glass doped with Nd2O3 studied through ultrafast z-scan spectroscopy

    Science.gov (United States)

    Moreira, L.; Falci, R. F.; Darabian, H.; Anjos, V.; Bell, M. J. V.; Kassab, L. R. P.; Bordon, C. D. S.; Doualan, J. L.; Camy, P.; Moncorgé, R.

    2018-05-01

    The research on Nd3+ doped new solid-state laser hosts with specific thermo-mechanical and optical properties is very active. Nd3+ doped tellurite glasses are suitable for these applications. They have high linear and nonlinear refraction index, wide transmittance range. The TeO2-ZnO (TZO) glass considered in the present work combines all those features and the nonlinear optical properties can be used for the development of Kerr-lens mode-locked sub picosecond lasers. Recently the laser performance of Nd3+ doped TZO glass and was reported and laser slope efficiency of 21% was observed. We investigate how the intensity variation and the silver nanoparticles codoping affects the nonlinear optical properties of Nd3+ doped TZO glasses. Intensity dependent nonlinear refraction indices coefficients at 750, 800 and 850 nm were observed. The nonlinear optical features were obtained through ultrafast single beam z-scan technique with excitations at 750, 800 and 850 nm and are up to two orders of magnitude higher than those reported in the literature.

  9. The effects of the intense laser field on the nonlinear optical properties of a cylindrical Ga{sub 1−x}Al{sub x}As/GaAs quantum dot under applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Kasapoglu, E., E-mail: ekasap@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mora-Ramos, M.E. [Centro de Investigación en Ciencias, Instituto de Ciencias Básicas y Aplicadas, Universidad Autóonoma del Estado de Morelos, Av. Universidad 1001, CP 62209 Cuernavaca, Morelos (Mexico); Sökmen, I. [Department of Physics, Dokuz Eylül University, 35160 Buca, İzmir (Turkey)

    2015-10-01

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change (the linear and third-order nonlinear) for transitions between different intersubbands in the Ga{sub 1−x}Al{sub x}As/GaAs cylindrical quantum dot under external electric field are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass approximation. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the electric and intense laser fields. By changing the intensities of the electric and laser fields, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • The effects of the non-resonant intense laser field and electric field on the nonlinear optical properties of cylindrical quantum dot are investigated. • The both total absorption coefficient and refractive index change are sensitive to dot dimensions and the effects of external fields. • By changing the external fields together with dot dimensions a blue or red shift can be obtained.

  10. Optical fibres sensor based in the intensity switch of a linear laser with two Bragg gratings; Sensor de fibra optica basado en el salto de intensidad de un laser lineal con dos rejillas de Bragg

    Energy Technology Data Exchange (ETDEWEB)

    Basurto P, M.A.; Kuzin, E.A.; Archundia B, C.; Marroquin, E.; May A, M.; Cerecedo N, H.H.; Sanchez M, J.J. [Departamento de Fotonica y Fisica Optica, Instituto Nacional de Astrofisica, Optica y Electronica (INAOE). Apartado Postal 51 y 216, 72000 Puebla (Mexico); Tentori S, D.; Marquez B, I.; Shliagin, M.; Miridonov, S. [Centro de Investigacion CESE (Mexico)

    2000-07-01

    In this work we propose a new configuration for an optical fiber temperature sensor, based on a linear type Er-doped fiber laser. The laser cavity consists of an Er-doped fiber and two identical Bragg gratings at the fiber ends (working as reflectors). Temperature changes are detected by measuring, through one of the gratings, the intensity variations atthe system's output. When the temperature of one of the Bragg gratings is modified, a wavelength shift of its spectral reflectivity is observed. Hence, the laser emission intensity of the system is modified. We present experimental results of the intensity switch observed when the temperature difference between the gratings detunes their spectral reflectance. Making use of this effect it is possible to develop limit comparators to bound the temperature range for the object under supervision. This limiting work can be performed with a high sensitivity using a very simple interrogation procedure. (Author)

  11. Grazing incidence beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.

    1985-01-01

    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  12. Radioinduced optic nerve neuropathy after treatment for nasopharynx cancer. About two cases and literature review

    International Nuclear Information System (INIS)

    Mnejja, W.; Siala, W.; Daoud, J.; Fki, J.; Ghorbel, M.; Frikha, M.

    2007-01-01

    The radioinduced neuropathy of the optic nerve is a rare and delayed complication. Its incidence is difficult to evaluate in the literature. It depends on the whole irradiation dose, fractionation and irradiated volume. Currently, it does not exist any efficient treatment, only the prevention play an important part on avoiding the high doses, and the broad irradiation volumes. The innovating techniques using conformal radiotherapy with or without modulated intensity could contribute to reduce this toxicity incidence. (N.C.)

  13. Distributed fluorescent optical fiber proximity sensor: Towards a proof of concept

    Science.gov (United States)

    Gălătuș, Ramona; Faragó, Paul; Miluski, Piotr; Valles, Juan-Antonio

    2018-06-01

    Fluorescent fibers are optical fibers which emit light as a response to an incident phenomenon, usually an incident light. Operation depends on the doping dyes, which determine specific fluorescence and optical characteristics useful in the development of optical sensors. In this work we propose a low-cost distributed proximity sensor implemented using a red fluorescent fiber, to provide a security option for a surface plasmon resonance system. Operation of the proposed sensor relies on having the incident illumination intensity varied by the presence or absence of an obstacle in the vicinity of the sensing element. This will influence the radiated fluorescence accordingly. The proposed setup for the implementation of the optical proximity sensor assumes having a high brightness LED deployed for axial fiber illumination and a blue LED for side illumination. Electronic processing then accounts for gain and digitization. Measurement results of the prototype validate the proposed concept.

  14. Pappus in optical space

    NARCIS (Netherlands)

    Koenderink, Jan J.; van Doorn, Andrea J.; Kappers, Astrid M L; Todd, James T.

    Optical space differs from physical space. The structure of optical space has generally been assumed to be metrical. In contradistinction, we do not assume any metric, but only incidence relations (i.e., we assume that optical points and lines exist and that two points define a unique line, and two

  15. Pappus in optical space

    NARCIS (Netherlands)

    Koenderink, J.J.; Doorn, A.J. van; Kappers, A.M.L.; Todd, J.T.

    2002-01-01

    Optical space differs from physical space. The structure of optical space has generallybeen assumed to be metrical. In contradistinction,we do not assume anymetric, but only incidence relations (i.e., we assume that optical points and lines exist and that two points define a unique line, and two

  16. Capillary optics for radiation focusing

    International Nuclear Information System (INIS)

    Peurrung, A.J.; Reeder, P.L.; Bliss, M.; Craig, R.A.; Lepel, E.A.; Stromswold, D.C.; Stoffels, J.; Sunberg, D.S.; Tenny, H.

    1996-11-01

    Capillary lens technology may ultimately bring benefits to neutron and x-ray-based science like conventional lenses with visible light. Although the technology is not yet 10 years old, these lenses have already had a significant impact in engineering, science, and medicine. Capillary lenses are advantageous when it is desirable to increase the radiation flux at a location without regard to its angular divergence. PNNL has worked to improve the technology in several ways. A single, optimally tapered capillary was manufactured, which allows intensity gains of a factor of 270 for an initially parallel, incident x-ray beam. Feasibility of constructing neutron lenses using 58 Ni (particularly effective at reflecting neutrons) has been explored. Three applications for capillary optics have been identified and studied: neutron telescope, Gandolphi x-ray diffractometry, and neutron radiotherapy. A brief guide is given for determining which potential applications are likely to be helped by capillary optics

  17. Computer generated holography with intensity-graded patterns

    Directory of Open Access Journals (Sweden)

    Rossella Conti

    2016-10-01

    Full Text Available Computer Generated Holography achieves patterned illumination at the sample plane through phase modulation of the laser beam at the objective back aperture. This is obtained by using liquid crystal-based spatial light modulators (LC-SLMs, which modulate the spatial phase of the incident laser beam. A variety of algorithms are employed to calculate the phase modulation masks addressed to the LC-SLM. These algorithms range from simple gratings-and-lenses to generate multiple diffraction-limited spots, to iterative Fourier-transform algorithms capable of generating arbitrary illumination shapes perfectly tailored on the base of the target contour. Applications for holographic light patterning include multi-trap optical tweezers, patterned voltage imaging and optical control of neuronal excitation using uncaging or optogenetics. These past implementations of computer generated holography used binary input profile to generate binary light distribution at the sample plane. Here we demonstrate that using graded input sources, enables generating intensity graded light patterns and extend the range of application of holographic light illumination. At first, we use intensity-graded holograms to compensate for LC-SLM position dependent diffraction efficiency or sample fluorescence inhomogeneity. Finally we show that intensity-graded holography can be used to equalize photo evoked currents from cells expressing different level of chanelrhodopsin2 (ChR2, one of the most commonly used optogenetics light gated channels, taking into account the non-linear dependence of channel opening on incident light.

  18. The effects of the electric and intense laser field on the binding energies of donor impurity states (1s and 2p±) and optical absorption between the related states in an asymmetric parabolic quantum well

    Science.gov (United States)

    Kasapoglu, E.; Sakiroglu, S.; Sökmen, I.; Restrepo, R. L.; Mora-Ramos, M. E.; Duque, C. A.

    2016-10-01

    We have calculated the effects of electric and intense laser fields on the binding energies of the ground and some excited states of conduction electrons coupled to shallow donor impurities as well as the total optical absorption coefficient for transitions between 1s and 2p± electron-impurity states in a asymmetric parabolic GaAs/Ga1-x AlxAs quantum well. The binding energies were obtained using the effective-mass approximation within a variational scheme. Total absorption coefficient (linear and nonlinear absorption coefficient) for the transitions between any two impurity states were calculated from first- and third-order dielectric susceptibilities derived within a perturbation expansion for the density matrix formalism. Our results show that the effects of the electric field, intense laser field, and the impurity location on the binding energy of 1s-impurity state are more pronounced compared with other impurity states. If the well center is changed to be Lc0), the effective well width decreases (increases), and thus we can obtain the red or blue shift in the resonant peak position of the absorption coefficient by changing the intensities of the electric and non-resonant intense laser field as well as dimensions of the well and impurity positions.

  19. 20040217 NATO Advanced Research Workshop on Quasi-Optical Control of Intense Microwave Transmission Nizhny Novgorod, Russia 17 - 20 Feb 2004 2004 novgorod20040217 20040220

    CERN Document Server

    Hirshfield, Jay L

    2005-01-01

    This volume assembles the texts of presentations given at the NATO-sponsored Advanced Research Workshop on Quasi-Optical Transmission of High-Power Microwaves, held in Nizhny Novgorod, Russia in February 2004. The presentations bridge a wide range of technical areas, but share common tools of analysis and design. Applications of quasi-optics extend to the use of high-power microwaves—including millimeter-waves— for radar and communications (especially deep space millimeter-wave systems, space debris detection radar, and radar for the detection of small targets moving over heavy clutter); particle accelerators (especially for a future high-acceleration-gradient electron-positron collider); plasma research (especially for controlled nuclear fusion and waste decontamination); and material processing (in particular, ceramic sintering with millimeter-waves, and the coating of metal surfaces with protective dielectric films.). Scientists and engineers working in any of these areas should benefit significantly f...

  20. Time-dependent scattering of incident light of various wavelengths in ferrofluids under external magnetic field

    Science.gov (United States)

    Jin, Jingyu; Song, Dongxing; Geng, Jiafeng; Jing, Dengwei

    2018-02-01

    Ferrofluids can exhibit the anisotropic thermodynamic properties under magnetic fields. The dynamic optical properties of ferrofluids in the presence of magnetic fields are of particular interest due to their potential application as various optical devices. Although time-dependent light scattering by ferrofluids have been extensively studied, the effect of wavelength of incident light have been rarely considered. Here, for the first time, we investigated both the time- and wavelength-dependent light scattering in water based ferrofluids containing Fe3O4 nanoparticles under an external magnetic field. The field-induced response behavior of the prepared ferrofluid samples was determined and verified first by thermal conductivity measurement and numerical simulation. Double-beam UV-Vis spectrophotometer was employed to record the temporal evolution of transmitted intensity of incident light of various wavelengths passing through the ferrofluid sample and propagating parallel to the applied field. As expected, the light intensity decreases to a certain value right after the field is turned on due to the thermal fluctuation induced disorder inside the flexible particle chains. Then the light intensity further decreases with time until the appearance of a minimum at time τ0 followed by an inversed increase before finally reaches equilibrium at a particular time. More importantly, the characteristic inversion time τ0 was found to follow a power law increase with the wavelength of incident light (τ0 ∼ λα, where α = 2.07). A quantitative explanation for the wavelength dependence of characteristic time was proposed based on the finite-difference time-domain (FDTD) method. The simulation results are in good agreement with our experimental observations. The time-dependent light scattering in ferrofluids under different incident wavelengths was rationalized by considering both the coarsening process of the particle chains and the occurrence of resonance within the

  1. Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Moinuddin, E-mail: moinuddin.hassan@fda.hhs.gov; Ilev, Ilko [Optical Therapeutics and Medical Nanophotonics Laboratory, Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993 (United States)

    2014-10-15

    Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

  2. The impact of an education program on hand hygiene compliance and nosocomial infection incidence in an urban neonatal intensive care unit: an intervention study with before and after comparison

    NARCIS (Netherlands)

    Helder, Onno K.; Brug, Johannes; Looman, Caspar W. N.; van Goudoever, Johannes B.; Kornelisse, René F.

    2010-01-01

    Nosocomial bloodstream infections are a major cause of morbidity and mortality in neonatal intensive care units. Appropriate hand hygiene is singled out as the most important measure in preventing these infections. However, hand hygiene compliance among healthcare professionals remains low despite

  3. 3-D dosimetric evaluation of 2.5 mm HD120 multileaf system for intensity modulated stereotactic radiosurgery using optical CT based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Wuu, C-S; Kessel, Jack; Xu, Y

    2009-01-01

    A Trilogy TX equipped with a 2.5 mm HD120 multileaf collimator system is available for the treatment of radiosurgery and IMRT. In this study, we evaluated the 3-D dosimetric impact of leaf width on an IMRT radiosurgery plan by comparing the target coverage and the dose gradient around the target, produced from both a 2.5 mm HD120 high-definition MLC system and a 5mm-leaf-width millennium 120 MLC system, using an optical CT based polymer gel dosimetry system. The 2.5 mm MLC improves target conformity and surrounding tissue sparing when compared to that of 5 mm MLC.

  4. Geometrical-optics approximation of forward scattering by coated particles.

    Science.gov (United States)

    Xu, Feng; Cai, Xiaoshu; Ren, Kuanfang

    2004-03-20

    By means of geometrical optics we present an approximation algorithm with which to accelerate the computation of scattering intensity distribution within a forward angular range (0 degrees-60 degrees) for coated particles illuminated by a collimated incident beam. Phases of emerging rays are exactly calculated to improve the approximation precision. This method proves effective for transparent and tiny absorbent particles with size parameters larger than 75 but fails to give good approximation results at scattering angles at which refractive rays are absent. When the absorption coefficient of a particle is greater than 0.01, the geometrical optics approximation is effective only for forward small angles, typically less than 10 degrees or so.

  5. Recruiting intensity

    OpenAIRE

    R. Jason Faberman

    2014-01-01

    To hire new workers, employers use a variety of recruiting methods in addition to posting a vacancy announcement. The intensity with which employers use these alternative methods can vary widely with a firm’s performance and with the business cycle. In fact, persistently low recruiting intensity helps to explain the sluggish pace of US job growth following the Great Recession.

  6. Highlights from 4STAR Sky-Scanning Retrievals of Aerosol Intensive Optical Properties from Multiple Field Campaigns with Detailed Comparisons of SSA Reported During SEAC4RS

    Science.gov (United States)

    Dunagan, Stephen E.

    2016-01-01

    The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument combines airborne sun tracking capabilities of the Ames Airborne Tracking Sun Photometer (AATS-14) with AERONET (Aerosol Robotic Network)-like sky-scanning capability and adds state-of-the-art fiber-coupled grating spectrometry to yield hyperspectral measurements of direct solar irradiance and angularly resolved sky radiance. The combination of sun-tracking and sky-scanning capability enables retrievals of wavelength-dependent aerosol optical depth (AOD), mode-resolved aerosol size distribution (SD), asphericity, and complex refractive index, and thus also the scattering phase function, asymmetry parameter, single-scattering albedo (SSA), and absorption aerosol optical thickness (AAOT). From 2012 to 2014 4STAR participated in four major field campaigns: the U.S. Dept. of Energy's TCAP (Two-Column Aerosol Project) I & II campaigns, and NASA's SEAC4RS (Studies of Emissions, Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys) and ARISE (Arctic Radiation - IceBridge Sea & Ice Experiment) campaigns. Establishing a strong performance record, 4STAR operated successfully on all flights conducted during each of these campaigns. Sky radiance spectra from scans in either constant azimuth (principal plane) or constant zenith angle (almucantar) were interspersed with direct beam measurements during level legs. During SEAC4RS and ARISE, 4STAR airborne measurements were augmented with flight-level albedo from the collocated Shortwave Spectral Flux Radiometer (SSFR) providing improved specification of below-aircraft radiative conditions for the retrieval. Calibrated radiances and retrieved products will be presented with particular emphasis on detailed comparisons of ambient SSA retrievals and measurements during SEAC4RS from 4STAR, AERONET, HSRL2 (High Spectral Resolution Lidar), and from in situ measurements.

  7. 4STAR Sky-Scanning Retrievals of Aerosol Intensive Optical Properties from Multiple Field Campaigns with Detailed Comparisons of SSA Reported During SEAC4RS

    Science.gov (United States)

    Flynn, Connor; Dahlgren, R. P.; Dunagan, S.; Johnson, R.; Kacenelenbogen, M.; LeBlanc, S.; Livingston, J.; Redemann, J.; Schmid, B.; Segal Rozenhaimer, M.; hide

    2015-01-01

    The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument combines airborne sun tracking capabilities of the Ames Airborne Tracking Sun Photometer (AATS-14) with AERONET-like sky-scanning capability and adds state-of-the-art fiber-coupled grating spectrometry to yield hyper spectral measurements of direct solar irradiance and angularly resolved sky radiance. The combination of sun-tracking and sky-scanning capability enables retrievals of wavelength-dependent aerosol optical depth (AOD), mode-resolved aerosol size distribution (SD), asphericity, and complex refractive index, and thus also the scattering phase function, asymmetry parameter, single-scattering albedo (SSA), and absorption aerosol optical thickness (AAOT).From 2012 to 2014 4STAR participated in four major field campaigns: the U.S. Dept. of Energy TCAP I II campaigns, and NASAs SEAC4RS and ARISE campaigns. Establishing a strong performance record, 4STAR operated successfully on all flights conducted during each of these campaigns. Sky radiance spectra from scans in either constant azimuth (principal plane) or constant zenith angle (almucantar) were interspersed with direct beam measurements during level legs. During SEAC4RS and ARISE, 4STAR airborne measurements were augmented with flight-level albedo from the collocated Shortwave Spectral Flux Radiometer (SSFR) providing improved specification of below-aircraft radiative conditions for the retrieval. Calibrated radiances and retrieved products will be presented with particular emphasis on detailed comparisons of ambient SSA retrievals and measurements during SEAC4RS from 4STAR, AERONET, HSRL2, and from in situ measurements.

  8. Optical bistability and limiting in polymer dispersed liquid crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yshino, K.; Tagawa, A.; Sadohara, Y.; Ozaki, M. (Osaka University, Osaka (Japan). Faculty of Engineering); Munezawa, T. (Ajinomoto Co. Inc., Tokyo (Japan)); Nomura, Y. (Takiron Co. Ltd., Osaka (Japan))

    1991-04-15

    The linear electro-optical effect of polymer dispersed liquid crystal (PDLC) and the nonlinear optical response of electrically feedbacked PDLC were studied. Electro-optical limiting and bistability were observed in PDLCs with negative and positive feedback, respectively. In the PDLC film with positive feedback gain, an optical hysteresis loop shifted toward a high intensity region with decreasing magnitude of the feedback gain. The switching between high and low transmission states in an optical bistable region was realized by controlling incident light, and the on-off switching by superimposing light pulse on incident light for an extremely short period (several hundreds {mu}s). As the light pulse was strong, the minimum pulse width required for switching was as short as 500 {mu}s or less. The on-off switching was also realized by shutting out the incident light for a period equivalent to the pulse width. Slower response times of the PDLC film required longer minimum pulse widths. 12 refs., 11 figs.

  9. Mach-Zehnder interferometer implementation for thermo-optical and Kerr effect study

    Science.gov (United States)

    Bundulis, Arturs; Nitiss, Edgars; Busenbergs, Janis; Rutkis, Martins

    2018-04-01

    In this paper, we propose the Mach-Zehnder interferometric method for third-order nonlinear optical and thermo-optical studies. Both effects manifest themselves as refractive index dependence on the incident light intensity and are widely employed for multiple opto-optical and thermo-optical applications. With the implemented method, we have measured the Kerr and thermo-optical coefficients of chloroform under CW, ns and ps laser irradiance. The application of lasers with different light wavelengths, pulse duration and energy allowed us to distinguish the processes responsible for refractive index changes in the investigated solution. Presented setup was also used for demonstration of opto-optical switching. Results from Mach-Zehnder experiment were compared to Z-scan data obtained in our previous studies. Based on this, a quality comparison of both methods was assessed and advantages and disadvantages of each method were analyzed.

  10. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  11. Method and apparatus of highly linear optical modulation

    Science.gov (United States)

    DeRose, Christopher; Watts, Michael R.

    2016-05-03

    In a new optical intensity modulator, a nonlinear change in refractive index is used to balance the nonlinearities in the optical transfer function in a way that leads to highly linear optical intensity modulation.

  12. Analysis of artificial opals by scanning near field optical microscopy

    Science.gov (United States)

    Barrio, J.; Lozano, G.; Lamela, J.; Lifante, G.; Dorado, L. A.; Depine, R. A.; Jaque, F.; Míguez, H.

    2011-04-01

    Herein we present a detailed analysis of the optical response of artificial opal films realized employing a near-field scanning optical microscope in collection and transmission modes. Near-field patterns measured at the rear surface when a plane wave impinges on the front face are presented with the finding that optical intensity maps present a clear correlation with the periodic arrangement of the outer surface. Calculations based on the vector Korringa-Kohn-Rostoker method reproduce the different profiles experimentally observed as well as the response to the polarization of the incident field. These observations constitute the first experimental confirmation of the collective lattice resonances that give rise to the optical response of these three dimensional periodic structures in the high-energy range.

  13. Sound intensity

    DEFF Research Database (Denmark)

    Crocker, Malcolm J.; Jacobsen, Finn

    1998-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  14. Sound Intensity

    DEFF Research Database (Denmark)

    Crocker, M.J.; Jacobsen, Finn

    1997-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  15. Quantum optics

    International Nuclear Information System (INIS)

    Flytzanis, C.

    1988-01-01

    The 1988 progress report of the Quantum Optics laboratory (Polytechnic School, France) is presented. The research program is focused on the behavior of dense and dilute materials submitted to short and high-intensity light radiation fields. Nonlinear optics techniques, with time and spatial resolution, are developed. An important research activity concerns the investigations on the interactions between the photon beams and the inhomogeneous or composite materials, as well as the artificial microstructures. In the processes involving molecular beams and surfaces, the research works on the photophysics of surfaces and the molecule-surface interactions, are included [fr

  16. Efficient optical trapping of CdTe quantum dots by femtosecond laser pulses

    KAUST Repository

    Chiang, Weiyi

    2014-12-11

    The development in optical trapping and manipulation has been showing rapid progress, most of it is in the small particle sizes in nanometer scales, substituting the conventional continuous-wave lasers with high-repetition-rate ultrashort laser pulse train and nonlinear optical effects. Here, we evaluate two-photon absorption in optical trapping of 2.7 nm-sized CdTe quantum dots (QDs) with high-repetition-rate femtosecond pulse train by probing laser intensity dependence of both Rayleigh scattering image and the two-photon-induced luminescence spectrum of the optically trapped QDs. The Rayleigh scattering imaging indicates that the two-photon absorption (TPA) process enhances trapping ability of the QDs. Similarly, a nonlinear increase of the two-photon-induced luminescence with the incident laser intensity fairly indicates the existence of the TPA process.

  17. pH-dependent optical properties of N-acetyl-L-cysteine-capped ZnSe(S) nanocrystals with intense/stable emissions

    Science.gov (United States)

    Soheyli, Ehsan; Sahraei, Reza; Nabiyouni, Gholamreza

    2017-03-01

    In the present study, a series of aqueous-based ZnSe(S) nanocrystals (NCs) was prepared at different solution pH ranging from 8 to 11.9, and using N-acetyl-L-cysteine (NAC) as capping agent. In addition to zinc blende structure, the X-ray diffraction studies demonstrated the quantum size regime of the ZnSe(S) NCs. To gain further insight toward the influence of the quantum confinement and pH values on optical properties of the as-prepared NCs, their UV-visible absorption and photoluminescence spectra were systematically analyzed. The absorption spectra experienced a red shift from 340 to 382 nm as the pH increased from 8.0 to 11.9, indicating the growth of the as-prepared ZnSe(S) NCs. The emission spectra also show the obvious red shift and the relative area of excitonic to trap emission, firstly increases from pH = 8.0 to 10.7, and then decreases by further increasing of the solution pH. The initial behavior might be due to the improved surface passivation of the trap dangling states by better deprotonation of thiol groups in NAC, whereas at pH >10.7, the faster growth rate of the ZnSe(s) NCs may lead to the formation of many defect sites. All of these phenomena were combined in the scheme which displays the effect of quantum confinement and solution pH on variation of the excitonic and trap-related emissions.

  18. pH-dependent optical properties of N-acetyl-L-cysteine-capped ZnSe(S) nanocrystals with intense/stable emissions

    Energy Technology Data Exchange (ETDEWEB)

    Soheyli, Ehsan [University of Arak, Department of Physics, Faculty of Science (Iran, Islamic Republic of); Sahraei, Reza, E-mail: r.sahraei@ilam.ac.ir [University of Ilam, Department of Chemistry, Faculty of Science (Iran, Islamic Republic of); Nabiyouni, Gholamreza [University of Arak, Department of Physics, Faculty of Science (Iran, Islamic Republic of)

    2017-03-15

    In the present study, a series of aqueous-based ZnSe(S) nanocrystals (NCs) was prepared at different solution pH ranging from 8 to 11.9, and using N-acetyl-L-cysteine (NAC) as capping agent. In addition to zinc blende structure, the X-ray diffraction studies demonstrated the quantum size regime of the ZnSe(S) NCs. To gain further insight toward the influence of the quantum confinement and pH values on optical properties of the as-prepared NCs, their UV-visible absorption and photoluminescence spectra were systematically analyzed. The absorption spectra experienced a red shift from ~340 to ~382 nm as the pH increased from 8.0 to 11.9, indicating the growth of the as-prepared ZnSe(S) NCs. The emission spectra also show the obvious red shift and the relative area of excitonic to trap emission, firstly increases from pH = 8.0 to 10.7, and then decreases by further increasing of the solution pH. The initial behavior might be due to the improved surface passivation of the trap dangling states by better deprotonation of thiol groups in NAC, whereas at pH >10.7, the faster growth rate of the ZnSe(s) NCs may lead to the formation of many defect sites. All of these phenomena were combined in the scheme which displays the effect of quantum confinement and solution pH on variation of the excitonic and trap-related emissions.

  19. Introduction to nonimaging optics

    CERN Document Server

    Chaves, Julio

    2015-01-01

    Introduction to Nonimaging Optics covers the theoretical foundations and design methods of nonimaging optics, as well as key concepts from related fields. This fully updated, revised, and expanded Second Edition: Features a new and intuitive introduction with a basic description of the advantages of nonimaging opticsAdds new chapters on wavefronts for a prescribed output (irradiance or intensity), infinitesimal étendue optics (generalization of the aplanatic optics), and Köhler optics and color mixingIncorporates new material on the simultaneous multiple surface (SMS) design method in 3-D, int

  20. Periodic reversal of magneto-optic Faraday rotation on uniaxial birefringence crystal with ultrathin magnetic films

    Directory of Open Access Journals (Sweden)

    C. W. Su

    2013-07-01

    Full Text Available An experimental approach of inclined incidence magneto-optic Faraday effect observed in the polar plane is applied. Three samples containing ferromagnetic cobalt ultrathin films on a semiconductor zinc oxide (0001 single crystal substrate with in-plane and out-of-plane anisotropy are evaluated. Through the fine adjustment of crossed polarizers in the magneto-optic effect measurement completely recorded the detail optical and magneto-optical responses from the birefringent crystal substrate and the magnetic film, especially for the signal induced from the substrate with uniaxial optical axis. The angle dependency of interference phenomena periodically from the optical and magneto-optical responses is attributed to the birefringence even in the absence of a magnetic field. The new type of observation finds that the transmission Faraday intensity in the oblique incidence includes a combination of polarization rotations, which results from optical compensation from the substrate and magneto-optical Faraday effects from the film. The samples grown at different rates and examined by this method exhibit magnetic structure discriminations. This result can be applied in the advanced polarized-light technologies to enhance the spatial resolution of magnetic surfaces with microstructural information under various magnetic field direction.

  1. Linear and nonlinear intraband optical properties of ZnO quantum dots embedded in SiO2 matrix

    Directory of Open Access Journals (Sweden)

    Deepti Maikhuri

    2012-03-01

    Full Text Available In this work we investigate some optical properties of semiconductor ZnO spherical quantum dot embedded in an amorphous SiO2 dielectric matrix. Using the framework of effective mass approximation, we have studied intraband S-P, and P-D transitions in a singly charged spherical ZnO quantum dot. The optical properties are investigated in terms of the linear and nonlinear photoabsorption coefficient, the change in refractive index, and the third order nonlinear susceptibility and oscillator strengths. Using the parabolic confinement potential of electron in the dot these parameters are studied with the variation of the dot size, and the energy and intensity of incident radiation. The photoionization cross sections are also obtained for the different dot radii from the initial ground state of the dot. It is found that dot size, confinement potential, and incident radiation intensity affects intraband optical properties of the dot significantly.

  2. Optical near-fields & nearfield optics

    OpenAIRE

    Meixner, Alfred J; Leiderer, Paul

    2014-01-01

    Optical methods provide exceedingly powerful tools in science and technology for measuring, analyzing and manipulating, from optical microscopy and spectroscopy to the characterization of ultrafast processes by femtosecond pulses and the modification of materials by intense laser radiation. However, when it comes to applications in the nanometer-regime, the conventional optical techniques suffer from the resolution limit – formulated by Ernst Abbe one and a half centuries ago – that light can...

  3. Investigations on magnetic field induced optical transparency in magnetic nanofluids

    Science.gov (United States)

    Mohapatra, Dillip Kumar; Philip, John

    2018-02-01

    We study the magnetic field induced optical transparency and its origin in magnetic nanoemulsion of droplets of average size ∼200 nm containing superparamagnetic iron oxide nanoparticles. Beyond a certain volume fraction (Φ > 0.0021) of magnetic nanoemulsion and a critical magnetic field (Hc1), the transmitted light intensity increases drastically and reaches a maximum at another critical magnetic field (Hc2), beyond which the transmitted light intensity decreases and reaches a plateau. Interestingly, the transmitted light intensity at Hc2 is found to increase linearly with Φ and the critical magnetic fields Hc1 and Hc2 follow power law decay with Φ (i.e. Hc ∼ Φ-x), with exponents 0.48 and 0.27, respectively. The light intensity recovers to its initial value when the magnetic field is switched off, indicating the perfect reversibility of the field induced transparency process. The observed straight line scattered patterns above Hc2, on a screen placed perpendicular to the incident beam, confirms the formation of rod like anisotropic nanostructures perpendicular to the direction of light propagation. The magneto-optical measurements in the emulsion confirm that the observed field induced transparency in magnetic emulsions for Φ > 0.0021 is due to the optical birefringence caused by the rod like nanostructures. The reduced birefringence is found to be proportional to the square of the applied magnetic field. This finding offers several possibilities in using magnetic nanofluids in tunable optical devices.

  4. Optical design of a LED searchlight system

    Science.gov (United States)

    Gong, Chen; Xu, Haiping; Liang, Jinhua; Liu, Yunfei; Yuan, Zengquan

    2018-01-01

    A 1200m visible searchlight system is designed based on photometry and application of geometric optics. To generate intensity distribution of this relatively powerful light beam we propose to use a high power LED and several refractive optical elements, which are composed of two plane-convex lenses and a conventional Fresnel lens. Two plane-convex lenses enable refraction of the side rays from the LED to the front direction which incident on the Fresnel lens. Fresnel lens, in its turn, concentrate the light flux and provide a nearly collimated beam to meet the requirement of forming a well-illuminated area across the road in the far field. Simulation data shows that this searchlight allow generating an appropriate illumination distribution for the long range requirements. A proof-of-concept prototype producing acceptable illuminance is developed.

  5. Combined holographic-mechanical optical tweezers: Construction, optimization, and calibration

    Science.gov (United States)

    Hanes, Richard D. L.; Jenkins, Matthew C.; Egelhaaf, Stefan U.

    2009-08-01

    A spatial light modulator (SLM) and a pair of galvanometer-mounted mirrors (GMM) were combined into an optical tweezers setup. This provides great flexibility as the SLM creates an array of traps, which can be moved smoothly and quickly with the GMM. To optimize performance, the effect of the incidence angle on the SLM with respect to phase and intensity response was investigated. Although it is common to use the SLM at an incidence angle of 45°, smaller angles give a full 2π phase shift and an output intensity which is less dependent on the magnitude of the phase shift. The traps were calibrated using an active oscillatory technique and a passive probability distribution method.

  6. Combined holographic-mechanical optical tweezers: Construction, optimization, and calibration

    International Nuclear Information System (INIS)

    Hanes, Richard D. L.; Jenkins, Matthew C.; Egelhaaf, Stefan U.

    2009-01-01

    A spatial light modulator (SLM) and a pair of galvanometer-mounted mirrors (GMM) were combined into an optical tweezers setup. This provides great flexibility as the SLM creates an array of traps, which can be moved smoothly and quickly with the GMM. To optimize performance, the effect of the incidence angle on the SLM with respect to phase and intensity response was investigated. Although it is common to use the SLM at an incidence angle of 45 deg., smaller angles give a full 2π phase shift and an output intensity which is less dependent on the magnitude of the phase shift. The traps were calibrated using an active oscillatory technique and a passive probability distribution method.

  7. Holographic Optical Data Storage

    Science.gov (United States)

    Timucin, Dogan A.; Downie, John D.; Norvig, Peter (Technical Monitor)

    2000-01-01

    Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising

  8. Linear and nonlinear optical absorption coefficients in GaAs/Ga1−xAlxAs concentric double quantum rings: Effects of hydrostatic pressure and aluminum concentration

    International Nuclear Information System (INIS)

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A.; Restrepo, R.L.; Duque, C.A.

    2013-01-01

    The linear and nonlinear intra-band optical absorption coefficients in GaAs/Ga 1−x Al x As two-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and aluminum concentration the energies of the ground (n=1,l=0) and the first excited state (n=2,l=1) have been found using the effective mass approximation and the transfer matrix formalism. The energies of these states and the corresponding threshold energy of the intra-band optical transitions are examined as a function of hydrostatic pressure and aluminum concentration for different sizes of the structure. We also investigated the dependencies of the linear, nonlinear, and total optical absorption coefficients as functions of the incident photon energy for different values of hydrostatic pressure, aluminum concentration, sizes of the structure, and incident optical intensity. Its is found that the effects of the hydrostatic pressure and the aluminum concentration lead to a shifting of the resonant peaks of the intra-band optical spectrum. - Highlights: ► Linear and nonlinear intra-band absorption in quantum rings. ► Threshold energy strongly depends on the hydrostatic pressure. ► Threshold energy strongly depends on the stoichiometry and sizes of structure. ► Optical absorption is affected by the incident optical intensity.

  9. [Medication errors in Spanish intensive care units].

    Science.gov (United States)

    Merino, P; Martín, M C; Alonso, A; Gutiérrez, I; Alvarez, J; Becerril, F

    2013-01-01

    To estimate the incidence of medication errors in Spanish intensive care units. Post hoc study of the SYREC trial. A longitudinal observational study carried out during 24 hours in patients admitted to the ICU. Spanish intensive care units. Patients admitted to the intensive care unit participating in the SYREC during the period of study. Risk, individual risk, and rate of medication errors. The final study sample consisted of 1017 patients from 79 intensive care units; 591 (58%) were affected by one or more incidents. Of these, 253 (43%) had at least one medication-related incident. The total number of incidents reported was 1424, of which 350 (25%) were medication errors. The risk of suffering at least one incident was 22% (IQR: 8-50%) while the individual risk was 21% (IQR: 8-42%). The medication error rate was 1.13 medication errors per 100 patient-days of stay. Most incidents occurred in the prescription (34%) and administration (28%) phases, 16% resulted in patient harm, and 82% were considered "totally avoidable". Medication errors are among the most frequent types of incidents in critically ill patients, and are more common in the prescription and administration stages. Although most such incidents have no clinical consequences, a significant percentage prove harmful for the patient, and a large proportion are avoidable. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  10. Intensive mobilities

    DEFF Research Database (Denmark)

    Vannini, Phillip; Bissell, David; Jensen, Ole B.

    with fieldwork conducted in Canada, Denmark and Australia to develop our understanding of the experiential politics of long distance workers. Rather than focusing on the extensive dimensions of mobilities that are implicated in patterns and trends, our paper turns to the intensive dimensions of this experience......This paper explores the intensities of long distance commuting journeys as a way of exploring how bodily sensibilities are being changed by the mobilities that they undertake. The context of this paper is that many people are travelling further to work than ever before owing to a variety of factors...... which relate to transport, housing and employment. Yet we argue that the experiential dimensions of long distance mobilities have not received the attention that they deserve within geographical research on mobilities. This paper combines ideas from mobilities research and contemporary social theory...

  11. Radioinduced optic nerve neuropathy after treatment for nasopharynx cancer. About two cases and literature review; Neuropathie radio-induite du nerf optique apres traitement pour cancer du nasopharynx. A propos de deux cas et revue de la litterature

    Energy Technology Data Exchange (ETDEWEB)

    Mnejja, W.; Siala, W.; Daoud, J. [Centre Hospitalier Universitaire Habib-Bourguiba, Service de Radiotherapie Carcinologique, Sfax (Tunisia); Fki, J. [Centre Hospitalier Universitaire Habib-Bourguiba, Service d' Ophtalmologie, Sfax (Tunisia); Ghorbel, M. [Centre Hospitalier Universitaire Habib-Bourguiba, Service d' ORL, Sfax (Tunisia); Frikha, M. [Centre Hospitalier Universitaire Habib-Bourguiba, Service de Carcinologie Medicale, Sfax (Tunisia)

    2007-11-15

    The radioinduced neuropathy of the optic nerve is a rare and delayed complication. Its incidence is difficult to evaluate in the literature. It depends on the whole irradiation dose, fractionation and irradiated volume. Currently, it does not exist any efficient treatment, only the prevention play an important part on avoiding the high doses, and the broad irradiation volumes. The innovating techniques using conformal radiotherapy with or without modulated intensity could contribute to reduce this toxicity incidence. (N.C.)

  12. SPS Machine Protection Incident in 2009

    CERN Document Server

    Wenninger, J

    2009-01-01

    During the 008 SPS run a single machine operation incident happened on June 27th when a high intensity CNGS beam was lost in a dipole of sextant 1 following a time system ‘freeze’. The vacuum chamber was punctured over a length of over 10 cm, and the vacuum in the affected sector rose to atmospheric pressure. The dipole was exchanged June 30th. This note describes the incident in detail and presents the measures taken to avoid a similar incident in the future.

  13. Incident Information Management Tool

    CERN Document Server

    Pejovic, Vladimir

    2015-01-01

    Flaws of\tcurrent incident information management at CMS and CERN\tare discussed. A new data\tmodel for future incident database is\tproposed and briefly described. Recently developed draft version of GIS-­‐based tool for incident tracking is presented.

  14. Optical materials

    International Nuclear Information System (INIS)

    Poker, D.B.; Ortiz, C.

    1989-01-01

    This book reports on: Diamond films, Synthesis of optical materials, Structure related optical properties, Radiation effects in optical materials, Characterization of optical materials, Deposition of optical thin films, and Optical fibers and waveguides

  15. Grazing incidence diffraction : A review

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, B [LTPCM, ENSEEG. St. Martin d` Heres. (France)

    1996-09-01

    Different Grazing Incidence Diffraction (GID) methods for the analysis of thin films and multilayer structures are reviewed in three sections: the reflectivity is developed in the first one, which includes the non-specular diffuse scattering. The second one is devoted to the extremely asymmetric Bragg diffraction and the third one to the in-plane Bragg diffraction. Analytical formulations of the scattered intensities are developed for each geometry, in the framework of the kinetical analysis as well as the dynamical theory. Experimental examples are given to illustrate the quantitative possibility of the GID techniques.

  16. Intense electron and ion beams

    CERN Document Server

    Molokovsky, Sergey Ivanovich

    2005-01-01

    Intense Ion and Electron Beams treats intense charged-particle beams used in vacuum tubes, particle beam technology and experimental installations such as free electron lasers and accelerators. It addresses, among other things, the physics and basic theory of intense charged-particle beams; computation and design of charged-particle guns and focusing systems; multiple-beam charged-particle systems; and experimental methods for investigating intense particle beams. The coverage is carefully balanced between the physics of intense charged-particle beams and the design of optical systems for their formation and focusing. It can be recommended to all scientists studying or applying vacuum electronics and charged-particle beam technology, including students, engineers and researchers.

  17. Optical phase conjugation

    CERN Document Server

    Fisher, Robert A

    1983-01-01

    This book appears at a time of intense activity in optical phase conjugation. We chose not to await the maturation of the field, but instead to provide this material in time to be useful in its development. We have tried very hard to elucidate and interrelate the various nonlinear phenomena which can be used for optical phase conjugation.

  18. Optical measurement of microroughness of pigment coatings on rough substrates

    Science.gov (United States)

    Elton, N. J.

    2009-02-01

    The optical determination of rms roughness at the sub-wavelength scale by measurement of specular intensity as a function of wavelength or angle of incidence is well known. The method is normally used for specimens that are macroscopically flat. However, important industrial materials such as coated paper and paint consist of microscopically rough pigment coatings on a macroscopically rough substrate. Numerical modelling is used to assess the applicability and limitations of optical measurement of microroughness for such materials. Experimental results are presented for a range of paints on substrates of various macroroughness. Model and data are in fair agreement and show that the presence of substrate macroroughness always leads to an underestimation of microroughness. Generally, optical measurements of microroughness are only comparable for substrates of similar macroroughness and a limiting value exists above which measurements may not be meaningful.

  19. Optical measurement of microroughness of pigment coatings on rough substrates

    International Nuclear Information System (INIS)

    Elton, N J

    2009-01-01

    The optical determination of rms roughness at the sub-wavelength scale by measurement of specular intensity as a function of wavelength or angle of incidence is well known. The method is normally used for specimens that are macroscopically flat. However, important industrial materials such as coated paper and paint consist of microscopically rough pigment coatings on a macroscopically rough substrate. Numerical modelling is used to assess the applicability and limitations of optical measurement of microroughness for such materials. Experimental results are presented for a range of paints on substrates of various macroroughness. Model and data are in fair agreement and show that the presence of substrate macroroughness always leads to an underestimation of microroughness. Generally, optical measurements of microroughness are only comparable for substrates of similar macroroughness and a limiting value exists above which measurements may not be meaningful

  20. High transmittance optical films based on quantum dot doped nanoscale polymer dispersed liquid crystals

    Science.gov (United States)

    Gandhi, Sahil Sandesh; Chien, Liang-Chy

    2016-04-01

    We propose a simple way to fabricate highly transparent nanoscale polymer dispersed liquid crystal (nano-PDLC) films between glass substrates and investigate their incident angle dependent optical transmittance properties with both collimated and Lambertian intensity distribution light sources. We also demonstrate that doping nano-PDLC films with 0.1% InP/ZnS core/shell quantum dots (QD) results in a higher optical transmittance. This work lays the foundation for such nanostructured composites to potentially serve as roll-to-roll coatable light extraction or brightness enhancement films in emissive display applications, superior to complex nanocorrugation techniques proposed in the past.

  1. Linear and nonlinear intersubband optical absorption in a disk-shaped quantum dot with a parabolic potential plus an inverse squared potential in a static magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Liu Guanghui [Department of Physics, College of Physics and Electronic Engineering, Guangzhou University, Guangzhou 510006 (China); Guo Kangxian, E-mail: axguo@sohu.com [Department of Physics, College of Physics and Electronic Engineering, Guangzhou University, Guangzhou 510006 (China); Wang Chao [Institute of Public Administration, Guangzhou University, Guangzhou 510006 (China)

    2012-06-15

    The linear and nonlinear optical absorption in a disk-shaped quantum dot (DSQD) with parabolic potential plus an inverse squared potential in the presence of a static magnetic field are theoretically investigated within the framework of the compact-density-matrix approach and iterative method. The energy levels and the wave functions of an electron in the DSQD are obtained by using the effective mass approximation. Numerical calculations are presented for typical GaAs/AlAs DSQD. It is found that the optical absorption coefficients are strongly affected not only by a static magnetic field, but also by the strength of external field, the confinement frequency and the incident optical intensity.

  2. Linear and nonlinear intersubband optical absorption in a disk-shaped quantum dot with a parabolic potential plus an inverse squared potential in a static magnetic field

    International Nuclear Information System (INIS)

    Liu Guanghui; Guo Kangxian; Wang Chao

    2012-01-01

    The linear and nonlinear optical absorption in a disk-shaped quantum dot (DSQD) with parabolic potential plus an inverse squared potential in the presence of a static magnetic field are theoretically investigated within the framework of the compact-density-matrix approach and iterative method. The energy levels and the wave functions of an electron in the DSQD are obtained by using the effective mass approximation. Numerical calculations are presented for typical GaAs/AlAs DSQD. It is found that the optical absorption coefficients are strongly affected not only by a static magnetic field, but also by the strength of external field, the confinement frequency and the incident optical intensity.

  3. Intense, ultrashort light and dense, hot matter

    Indian Academy of Sciences (India)

    This article presents an overview of the physics and applications of the interaction of high intensity laser light with matter. It traces the crucial advances that have occurred over the past few decades in laser technology and nonlinear optics and then discusses physical phenomena that occur in intense laser fields and their ...

  4. Linear and nonlinear optical absorption coefficients in GaAs/Ga{sub 1-x}Al{sub x}As concentric double quantum rings: Effects of hydrostatic pressure and aluminum concentration

    Energy Technology Data Exchange (ETDEWEB)

    Baghramyan, H.M. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Barseghyan, M.G., E-mail: mbarsegh@ysu.am [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Kirakosyan, A.A. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Restrepo, R.L. [Escuela de Ingenieria de Antioquia, AA 7516 Medellin (Colombia); Duque, C.A. [Instituto de Fisica, Universidad de Antioquia, AA 1226 Medellin (Colombia)

    2013-02-15

    The linear and nonlinear intra-band optical absorption coefficients in GaAs/Ga{sub 1-x}Al{sub x}As two-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and aluminum concentration the energies of the ground (n=1,l=0) and the first excited state (n=2,l=1) have been found using the effective mass approximation and the transfer matrix formalism. The energies of these states and the corresponding threshold energy of the intra-band optical transitions are examined as a function of hydrostatic pressure and aluminum concentration for different sizes of the structure. We also investigated the dependencies of the linear, nonlinear, and total optical absorption coefficients as functions of the incident photon energy for different values of hydrostatic pressure, aluminum concentration, sizes of the structure, and incident optical intensity. Its is found that the effects of the hydrostatic pressure and the aluminum concentration lead to a shifting of the resonant peaks of the intra-band optical spectrum. - Highlights: Black-Right-Pointing-Pointer Linear and nonlinear intra-band absorption in quantum rings. Black-Right-Pointing-Pointer Threshold energy strongly depends on the hydrostatic pressure. Black-Right-Pointing-Pointer Threshold energy strongly depends on the stoichiometry and sizes of structure. Black-Right-Pointing-Pointer Optical absorption is affected by the incident optical intensity.

  5. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  6. Phenomenological dirac optical potential for neutron cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Shin-ichi; Kitsuki, Hirohiko; Shigyo, Nobuhiro; Ishibashi, Kenji [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering

    1997-03-01

    Because of limitation on neutron-incident data, it is difficult to obtain global optical model potential for neutrons. In contrast, there are some global optical model potentials for proton in detail. It is interesting to convert the proton-incident global optical potentials into neutron-incident ones. In this study we introduce (N-Z)/A dependent symmetry potential terms into the global proton-incident optical potentials, and then obtain neutron-incident ones. The neutron potentials reproduce total cross sections in an acceptable degree. However, a comparison with potentials proposed by other authors brings about a confused situation in the sign of the symmetry terms. (author)

  7. Cancer incidence among waiters

    DEFF Research Database (Denmark)

    Reijula, Jere; Kjaerheim, Kristina; Lynge, Elsebeth

    2015-01-01

    AIMS: To study cancer risk patterns among waiters in the Nordic countries. METHODS: We identified a cohort of 16,134 male and 81,838 female waiters from Denmark, Finland, Iceland, Norway and Sweden. During the follow-up period from 1961 to 2005, we found that 19,388 incident cancer cases were...... diagnosed. Standardised incidence ratio (SIR) was defined as the observed number of cancer cases divided by the expected number, based on national age, time period and gender-specific cancer incidence rates in the general population. RESULTS: The SIR of all cancers in waiters, in the five countries combined...... INCIDENCE IN SOME CANCER SITES CAN LIKELY BE EXPLAINED BY HIGHER ALCOHOL CONSUMPTION, THE PREVALENCE OF SMOKING AND OCCUPATIONAL EXPOSURE TO TOBACCO SMOKE HOPEFULLY, THE INCIDENCE OF CANCER AMONG WAITERS WILL DECREASE IN THE FUTURE, DUE TO THE BANNING OF TOBACCO SMOKING IN RESTAURANTS AND BARS IN THE NORDIC...

  8. Increase of Prostate Cancer Incidence in Martinique

    Directory of Open Access Journals (Sweden)

    Dominique Belpomme

    2011-01-01

    Full Text Available Prostate cancer incidence is steadily increasing in many developed countries. Because insular populations present unique ethnic, geographical, and environmental characteristics, we analyzed the evolution of prostate cancer age-adjusted world standardized incidence rates in Martinique in comparison with that of metropolitan France. We also compared prostate cancer incidence rates, and lifestyle-related and socioeconomic markers such as life expectancy, dietary energy, and fat supply and consumption, with those in other Caribbean islands, France, UK, Sweden, and USA. The incidence rate of prostate cancer in Martinique is one of the highest reported worldwide; it is continuously growing since 1985 in an exponential mode, and despite a similar screening detection process and lifestyle-related behaviour, it is constantly at a higher level than in metropolitan France. However, Caribbean populations that are genetically close to that of Martinique have generally much lower incidence of prostate cancer. We found no correlation between prostate cancer incidence rates, life expectancy, and diet westernization. Since the Caribbean African descent-associated genetic susceptibility factor would have remained constant during the 1980–2005, we suggest that in Martinique some environmental change including the intensive use of carcinogenic organochlorine pesticides might have occurred as key determinant of the persisting highly growing incidence of prostate cancer.

  9. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  10. THz Induced Nonlinear Effects in Materials at Intensities above 26 GW/cm2

    Science.gov (United States)

    Woldegeorgis, A.; Kurihara, T.; Beleites, B.; Bossert, J.; Grosse, R.; Paulus, G. G.; Ronneberger, F.; Gopal, A.

    2018-04-01

    Nonlinear refractive index and absorption coefficient are measured for common semiconductor material such as silicon and organic molecule such as lactose in the terahertz (THz) spectral regime extending from 0.1 to 3 THz. Terahertz pulses with field strengths in excess of 4.4 MV/cm have been employed. Transmittance and the transmitted spectrum were measured with Z-scan and single shot noncollinear electro-optic pump-probe techniques. The THz-induced change in the refractive index (Δn) shows frequency-dependence and a maximum change of - 0.128 at 1.37 THz in lactose and up to + 0.169 at 0.15 THz in silicon was measured for a peak incident THz intensity of 26 GW/cm2. Furthermore, the refractive index variation shows a quadratic dependence on the incident THz field, implying the dominance of third-order nonlinearity.

  11. Nonimaging optics

    Science.gov (United States)

    Winston, Roland

    1991-03-01

    Various uses of nonimaging concentrators and advances in the field of nonimaging optics are discussed. A nonimaging concentrator acts as a type of funnel for light by collecting and intensifying radiation far better than a lens or mirror would. It thus has found useful applications in fields ranging from high-energy physics to solar energy. The history of the field of nonimaging optics is traced, beginning with the design of the first compound parabolic concentrators in the mid-1960s. It is noted that at present there are two known ways to design nonimaging concentrators: the edge-ray method and the geometric vector flux approach. The use of nonimaging optical devices in the design of nontracking solar concentrators is traced. It is noted that the upper limit of concentration turns out to be about 46,000 times the intensity of sunlight at the surface of the earth. Methods used to maximize this concentration are discussed. The development and use of a solar-pumped laser which would have applications in satellite communications are discussed.

  12. Diffractive nonimaging optics

    NARCIS (Netherlands)

    Jong, de T.M.

    2012-01-01

    Economic use of energy often depends on efficient management of light. Power generation from solar energy, for example, can involve optical systems that concentrate incident sunlight onto a small area and thereby reduce the required surface area of photovoltaic elements. Similarly, efficient

  13. Electromagnetic Launch Optical Telemetry Feasibility Study

    National Research Council Canada - National Science Library

    Snowden, P; Levinson, S. J

    2007-01-01

    .... At issue are the relative intensities of the optical noise received in the MCL catch tank from the muzzle flash versus the narrowband optical signal levels generated from tiny emitters onboard...

  14. Advances in thin film diffraction instrumentation by X-ray optics

    International Nuclear Information System (INIS)

    Haase, A.

    1996-01-01

    The structural characterisation of thin films requires a parallel X-ray beam of high intensity. Parallel beam geometry is commonly used in high resolution and single crystal experiments, but also in the field of X-ray diffraction for polycrystalline material (e.g. in phase, texture and stress analysis). For grazing incidence diffraction (GID), the use of small slits on the primary side and of long soller slits with a flat monochromator on the secondary side is standard. New optical elements have been introduced with polychromatic or monochromatic radiation. By means of different applications the results are compared with those of classical beam optics. X-ray fiber optics utilize total external reflection of X-rays on smooth surfaces. Effects of monochromatization are presented. In many fields of application, fiber optics may replace conventional collimators. The use of primary and secondary channel cut crystals can also produce a high parallel monochromatic X-ray beam. A parabolically bent graded multilayer produces a monochromatic parallel beam of high intensity. Compared with classical Bragg-Brentano (focussing) geometry, excellent results have been obtained, especially for samples with an irregular shape. In combination with a channel cut monochromator there is a substantial gain in intensity leading to an increase of the dynamic intensity range of rocking curves

  15. Advances in thin film diffraction instrumentation by X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Haase, A [Rich. Seifert and Co., Analytical X-ray Systems, Ahrensburg (Germany)

    1996-09-01

    The structural characterisation of thin films requires a parallel X-ray beam of high intensity. Parallel beam geometry is commonly used in high resolution and single crystal experiments, but also in the field of X-ray diffraction for polycrystalline material (e.g. in phase, texture and stress analysis). For grazing incidence diffraction (GID), the use of small slits on the primary side and of long soller slits with a flat monochromator on the secondary side is standard. New optical elements have been introduced with polychromatic or monochromatic radiation. By means of different applications the results are compared with those of classical beam optics. X-ray fiber optics utilize total external reflection of X-rays on smooth surfaces. Effects of monochromatization are presented. In many fields of application, fiber optics may replace conventional collimators. The use of primary and secondary channel cut crystals can also produce a high parallel monochromatic X-ray beam. A parabolically bent graded multilayer produces a monochromatic parallel beam of high intensity. Compared with classical Bragg-Brentano (focussing) geometry, excellent results have been obtained, especially for samples with an irregular shape. In combination with a channel cut monochromator there is a substantial gain in intensity leading to an increase of the dynamic intensity range of rocking curves.

  16. Imaging optical fields below metal films and metal-dielectric waveguides by a scanning microscope

    Science.gov (United States)

    Zhu, Liangfu; Wang, Yong; Zhang, Douguo; Wang, Ruxue; Qiu, Dong; Wang, Pei; Ming, Hai; Badugu, Ramachandram; Rosenfeld, Mary; Lakowicz, Joseph R.

    2017-09-01

    Laser scanning confocal fluorescence microscopy (LSCM) is now an important method for tissue and cell imaging when the samples are located on the surfaces of glass slides. In the past decade, there has been extensive development of nano-optical structures that display unique effects on incident and transmitted light, which will be used with novel configurations for medical and consumer products. For these applications, it is necessary to characterize the light distribution within short distances from the structures for efficient detection and elimination of bulky optical components. These devices will minimize or possibly eliminate the need for free-space light propagation outside of the device itself. We describe the use of the scanning function of a LSCM to obtain 3D images of the light intensities below the surface of nano-optical structures. More specifically, we image the spatial distributions inside the substrate of fluorescence emission coupled to waveguide modes after it leaks through thin metal films or dielectric-coated metal films. The observed spatial distribution were in general agreement with far-field calculations, but the scanning images also revealed light intensities at angles not observed with classical back focal plane imaging. Knowledge of the subsurface optical intensities will be crucial in the combination of nano-optical structures with rapidly evolving imaging detectors.

  17. Fiber optic hydrophone

    Science.gov (United States)

    Kuzmenko, Paul J.; Davis, Donald T.

    1994-01-01

    A miniature fiber optic hydrophone based on the principles of a Fabry-Perot interferometer. The hydrophone, in one embodiment, includes a body having a shaped flexible bladder at one end which defines a volume containing air or suitable gas, and including a membrane disposed adjacent a vent. An optic fiber extends into the body with one end terminating in spaced relation to the membrane. Acoustic waves in the water that impinge on the bladder cause the pressure of the volume therein to vary causing the membrane to deflect and modulate the reflectivity of the Fabry-Perot cavity formed by the membrane surface and the cleaved end of the optical fiber disposed adjacent to the membrane. When the light is transmitted down the optical fiber, the reflected signal is amplitude modulated by the incident acoustic wave. Another embodiment utilizes a fluid filled volume within which the fiber optic extends.

  18. System for testing optical fibers

    Science.gov (United States)

    Golob, John E. [Olathe, KS; Looney, Larry D. [Los Alamos, NM; Lyons, Peter B. [Los Alamos, NM; Nelson, Melvin A. [Santa Barbara, CA; Davies, Terence J. [Santa Barbara, CA

    1980-07-15

    A system for measuring a combination of optical transmission properties of fiber optic waveguides. A polarized light pulse probe is injected into one end of the optical fiber. Reflections from discontinuities within the fiber are unpolarized whereas reflections of the probe pulse incident to its injection remain polarized. The polarized reflections are prevented from reaching a light detector whereas reflections from the discontinuities reaches the detector.

  19. Police Incident Blotter (Archive)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Police Blotter Archive contains crime incident data after it has been validated and processed to meet Uniform Crime Reporting (UCR) standards, published on a...

  20. 2011 Japanese Nuclear Incident

    Science.gov (United States)

    EPA’s RadNet system monitored the environmental radiation levels in the United States and parts of the Pacific following the Japanese Nuclear Incident. Learn about EPA’s response and view historical laboratory data and news releases.

  1. Prediction of Safety Incidents

    Data.gov (United States)

    National Aeronautics and Space Administration — Safety incidents, including injuries, property damage and mission failures, cost NASA and contractors thousands of dollars in direct and indirect costs. This project...

  2. Marine Animal Incident Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Large whale stranding, death, ship strike and entanglement incidents are all recorded to monitor the health of each population and track anthropogenic factors that...

  3. Acute incidents during anaesthesia

    African Journals Online (AJOL)

    management of acute incidents and the prevention of ... High or total (complete) spinal blocks in obstetric .... Pain and opioid analgesics lead to delayed ... Step up postoperative care and use ... recognise suprasternal and supraclavicular.

  4. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, 4: ... ways to understand and measure the intensity of aerobic activity: relative intensity and absolute intensity. Relative Intensity ...

  5. Nonlinear atom optics and bright-gap-soliton generation in finite optical lattices

    International Nuclear Information System (INIS)

    Carusotto, Iacopo; Embriaco, Davide; La Rocca, Giuseppe C.

    2002-01-01

    We theoretically investigate the transmission dynamics of coherent matter wave pulses across finite optical lattices in both the linear and the nonlinear regimes. The shape and the intensity of the transmitted pulse are found to strongly depend on the parameters of the incident pulse, in particular its velocity and density: a clear physical picture of the main features observed in the numerical simulations is given in terms of the atomic band dispersion in the periodic potential of the optical lattice. Signatures of nonlinear effects due to the atom-atom interaction are discussed in detail, such as atom-optical limiting and atom-optical bistability. For positive scattering lengths, matter waves propagating close to the top of the valence band are shown to be subject to modulational instability. A scheme for the experimental generation of narrow bright gap solitons from a wide Bose-Einstein condensate is proposed: the modulational instability is seeded starting from the strongly modulated density profile of a standing matter wave and the solitonic nature of the generated pulses is checked from their shape and their collisional properties

  6. Plasmon-enhanced optically stimulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, E. J.; Baffa, O. [Universidade de Sao Paulo, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Departamento de Fisica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Ramos, A. P., E-mail: ederguidelli@gmail.com [Universidade de Sao Paulo, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Departamento de Quimica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil)

    2015-10-15

    Full text: Optically Stimulated Luminescence dosimeters (OSLD) have been largely used for personal, medical, and industrial radiation dosimetry. Developing highly sensitive and small-sized radiation detectors and dosimeters is essential for improving spatial resolution and consequently diagnosis quality and treatment efficacy in the case of applications in radiodiagnosis and radiation therapy, for instance. Conventional methods to improve the OSLD sensitivity consist of doping and co-doping the host materials with atoms of other elements, thereby increasing the amount of trapping and/or luminescent centers. Our group is researching on the use of the plasmon properties of noble metal nanoparticles to increase OSL intensity. Upon incidence of a light beam with appropriate resonant wavelengths, the oscillation of the free electrons at the nanoparticle surface originates the Localized Surface Plasmons (LSP) and the consequent plasmon resonance band. The interaction between the LSP and the surrounding luminescent material leads to new optical properties largely employed for enhancing several luminescent processes. Here we will show our results regarding the use of LSP to increase OSLD sensitivity. The interaction between the traps/luminescent centers and the plasmons depends on the distance between them, on the plasmon resonance band intensity and position, as well as on the surrounding medium. Therefore, the plasmon-enhanced luminescence is a promising tool to develop more sensitive and miniaturized OSLD. (Author)

  7. Plasmon-enhanced optically stimulated luminescence

    International Nuclear Information System (INIS)

    Guidelli, E. J.; Baffa, O.; Ramos, A. P.

    2015-10-01

    Full text: Optically Stimulated Luminescence dosimeters (OSLD) have been largely used for personal, medical, and industrial radiation dosimetry. Developing highly sensitive and small-sized radiation detectors and dosimeters is essential for improving spatial resolution and consequently diagnosis quality and treatment efficacy in the case of applications in radiodiagnosis and radiation therapy, for instance. Conventional methods to improve the OSLD sensitivity consist of doping and co-doping the host materials with atoms of other elements, thereby increasing the amount of trapping and/or luminescent centers. Our group is researching on the use of the plasmon properties of noble metal nanoparticles to increase OSL intensity. Upon incidence of a light beam with appropriate resonant wavelengths, the oscillation of the free electrons at the nanoparticle surface originates the Localized Surface Plasmons (LSP) and the consequent plasmon resonance band. The interaction between the LSP and the surrounding luminescent material leads to new optical properties largely employed for enhancing several luminescent processes. Here we will show our results regarding the use of LSP to increase OSLD sensitivity. The interaction between the traps/luminescent centers and the plasmons depends on the distance between them, on the plasmon resonance band intensity and position, as well as on the surrounding medium. Therefore, the plasmon-enhanced luminescence is a promising tool to develop more sensitive and miniaturized OSLD. (Author)

  8. Theoretical and Experimental Optical Evaluation and Comparison of Symmetric 2D CPC and V-Trough Collector for Photovoltaic Applications

    Directory of Open Access Journals (Sweden)

    Damasen Ikwaba Paul

    2015-01-01

    Full Text Available This paper presents theoretical and experimental optical evaluation and comparison of symmetric Compound Parabolic Concentrator (CPC and V-trough collector. For direct optical properties comparison, both concentrators were deliberately designed to have the same geometrical concentration ratio (1.96, aperture area, absorber area, and maximum concentrator length. The theoretical optical evaluation of the CPC and V-trough collector was carried out using a ray-trace technique while the experimental optical efficiency and solar energy flux distributions were analysed using an isolated cell PV module method. Results by simulation analysis showed that for the CPC, the highest optical efficiency was 95% achieved in the interval range of 0° to ±20° whereas the highest outdoor experimental optical efficiency was 94% in the interval range of 0° to ±20°. For the V-tough collector, the highest optical efficiency for simulation and outdoor experiments was about 96% and 93%, respectively, both in the interval range of 0° to ±5°. Simulation results also showed that the CPC and V-trough exhibit higher variation in non-illumination intensity distributions over the PV module surface for larger incidence angles than lower incidence angles. On the other hand, the maximum power output for the cells with concentrators varied depending on the location of the cell in the PV module.

  9. Raman spectroscopy an intensity approach

    CERN Document Server

    Guozhen, Wu

    2017-01-01

    This book summarizes the highlights of our work on the bond polarizability approach to the intensity analysis. The topics covered include surface enhanced Raman scattering, Raman excited virtual states and Raman optical activity (ROA). The first chapter briefly introduces the Raman effect in a succinct but clear way. Chapter 2 deals with the normal mode analysis. This is a basic tool for our work. Chapter 3 introduces our proposed algorithm for the Raman intensity analysis. Chapter 4 heavily introduces the physical picture of Raman virtual states. Chapter 5 offers details so that the readers can have a comprehensive idea of Raman virtual states. Chapter 6 demonstrates how this bond polarizability algorithm is extended to ROA intensity analysis. Chapters 7 and 8 offer details on ROA, showing many findings on ROA mechanism that were not known or neglected before. Chapter 9 introduces our proposed classical treatment on ROA which, as combined with the results from the bond polarizability analysis, leads to a com...

  10. Intense harmonic generation from various ablation media

    International Nuclear Information System (INIS)

    Ozaki, T.; Elouga, L.; Suzuki, M.; Kuroda, H.; Ganeev, R.A.

    2006-01-01

    Complete test of publication follows. High-order harmonic generation (HHG) is a unique source of coherent extreme ultraviolet (XUV) radiation, which can produce soft x-rays within the spectral 'water-window' (between 2.3 and 4.4 nm), and ultimately short pulses with attosecond duration. However, the intensity of present-day harmonics is still low, and serious applications will need an increase of the conversion efficiency. Instead of using gas media, one can also use ablation material, produced on solid targets using a low-intensity prepulse, as the nonlinear medium to generate high-order harmonics. Recently, we have successfully demonstrated the generation of up to the 63 rd harmonic (λ = 12.6 nm) of a Ti:sapphire laser radiation using boron ablation, and a strong enhancement in the intensity of the 13 th harmonic from indium ablation. These harmonics were generated with a modest laser (10 mJ, 150 fs) and with the pre-pulse to main pulse energy ratio constant. In this paper, we perform systematic investigations of ablation harmonics, using the 200 mJ, 30 fs Ti:sapphire beam line of the Canadian Advanced Laser Light Source (ALLS) facility. ALLS allows studying ablation harmonics over wider experimental parameters, and with independent control over the pre-pulse and main pulse energies. The 10 Hz, 200 mJ Ti:sapphire beam line of ALLS is divided into two beams. Each beam has its own energy control system, which allows independent control over the energy of each beam. One of the beams is used as a pre-pulse for creating ablation, which is focused onto the solid target without pulse compression, with pulse duration of 200 ps. The second beam is used as the main pulse for harmonic generation. The main pulse is delayed in time relative to the pre-pulse by propagating through an optical delay line, and then sent through a pulse compressor. The compressed pulse duration have typical pulse duration of 30 fs FWHM, which is then focused onto the ablation medium using MgF 2

  11. Figure and finish of grazing incidence mirrors

    International Nuclear Information System (INIS)

    Takacs, P.Z.; Church, E.L.

    1989-08-01

    Great improvement has been made in the past several years in the quality of optical components used in synchrotron radiation (SR) beamlines. Most of this progress has been the result of vastly improved metrology techniques and instrumentation permitting rapid and accurate measurement of the surface finish and figure on grazing incidence optics. A significant theoretical effort has linked the actual performance of components used as x-ray wavelengths to their topological properties as measured by surface profiling instruments. Next-generation advanced light sources will require optical components and systems to have sub-arc second surface figure tolerances. This paper will explore the consequences of these requirements in terms of manufacturing tolerances to see if the present manufacturing state-of-the-art is capable of producing the required surfaces. 15 refs., 14 figs., 2 tabs

  12. UltraForm Finisher Optical Mandrel Fabrication, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The requirements for cost effective manufacturing and metrology of normal incidence and grazing incidence X-Ray optical surfaces is instrumental for the success of...

  13. Recent Vegetation Fire Incidence in Russia

    OpenAIRE

    Hayasaka, Hiroshi

    2011-01-01

    MODIS hotspot data from NASA have now become a standard means of evaluating vegetation fires worldwide. Remote sensing is the most effective tool for large countries like Russia because it is hard to obtain exact, detailed forest fire data. Accumulated MODIS hotspot data of the nine years from 2002 to 2010 may allow us to assess recent changes in the vegetation fire incidence in Russia. This kind of analysis using various satellites is useful in estimating fire intensity and sever...

  14. Polaron effects on the linear and the nonlinear optical absorption coefficients and refractive index changes in cylindrical quantum dots with applied magnetic field

    International Nuclear Information System (INIS)

    Wu Qingjie; Guo Kangxian; Liu Guanghui; Wu Jinghe

    2013-01-01

    Polaron effects on the linear and the nonlinear optical absorption coefficients and refractive index changes in cylindrical quantum dots with the radial parabolic potential and the z-direction linear potential with applied magnetic field are theoretically investigated. The optical absorption coefficients and refractive index changes are presented by using the compact-density-matrix approach and iterative method. Numerical calculations are presented for GaAs/AlGaAs. It is found that taking into account the electron-LO-phonon interaction, not only are the linear, the nonlinear and the total optical absorption coefficients and refractive index changes enhanced, but also the total optical absorption coefficients are more sensitive to the incident optical intensity. It is also found that no matter whether the electron-LO-phonon interaction is considered or not, the absorption coefficients and refractive index changes above are strongly dependent on the radial frequency, the magnetic field and the linear potential coefficient.

  15. Hazmat Yearly Incident Summary Reports

    Data.gov (United States)

    Department of Transportation — Series of Incident data and summary statistics reports produced which provide statistical information on incidents by type, year, geographical location, and others....

  16. Radiation incidents in dentistry

    International Nuclear Information System (INIS)

    Lovelock, D.J.

    1996-01-01

    Most dental practitioners act as their own radiographer and radiologist, unlike their medical colleagues. Virtually all dental surgeons have a dental X-ray machine for intraoral radiography available to them and 40% of dental practices have equipment for dental panoramic tomography. Because of the low energy of X-ray equipment used in dentistry, radiation incidents tend to be less serious than those associated with other aspects of patient care. Details of 47 known incidents are given. The advent of the 1985 and 1988 Ionising Radiation Regulations has made dental surgeons more aware of the hazards of radiation. These regulations, and general health and safety legislation, have led to a few dental surgeons facing legal action. Because of the publicity associated with these court cases, it is expected that there will be a decrease in radiation incidents arising from the practice of dentistry. (author)

  17. X-ray grazing incidence study of inhomogeneous strain relaxation in Si/SiGe wires

    International Nuclear Information System (INIS)

    Hesse, A.; Zhuang, Y.; Holy, V.; Stangl, J.; Zerlauth, S.; Schaeffler, F.; Bauer, G.; Darowski, N.; Pietsch, U.

    2003-01-01

    The elastic strain relaxation in a series of dry-etched periodic multilayer Si/SiGe wire samples with different etching depths was investigated systematically by means of grazing incidence diffraction (GID). The samples were patterned by holographic lithography and reactive ion etching from a Si/SiGe superlattice grown by molecular beam epitaxy. Scanning electron microscopy and atomic force microscopy were employed to obtain information on the shape of the wires. The inhomogeneous strain distribution in the etched wires and in the non-etched part of the multilayers was derived by means of finite element calculations which were used as an input for simulations of the scattered X-ray intensities in depth dependent GID. The theoretical calculations for the scattered intensities are based on distorted-wave Born approximation. The unperturbed scattering potential was chosen with a reduced optical density corresponding to the ratio of wire width and wire period, in order to reflect the main interaction between the incident X-rays and the patterned samples. The calculations are in good agreement with the experimental data demonstrating the variation of strain relaxation with depth

  18. Optical and radar characterization of a short-lived auroral event at high latitude

    International Nuclear Information System (INIS)

    Vallance Jones, A.; Gattinger, R.L.; Shih, P.; Meriwether, J.W.; Wickwar, V.B.; Kelly, J.

    1987-01-01

    Observations of optical emission intensities and incoherent scatter radar returns in the magnetic zenith were compared in a study carried out at Sondre Stromfjord (Λ = 76.1 degree) in Greenland. The results were used to test the consistency of a theoretical model of ion chemistry and optical emissions in aurora and to explore the accuracy of relations between optical measurements and the average energy of the incident electrons. The incident primary electron spectrum and its temporal variation were inferred from zenith electron density profiles from the radar. The inferred primary energy spectrum at the peak intensity of the event approximated a Maxwellian distribution of characteristic energy 1.3 keV accelerated by an energy increment between 2 and 5 keV. Average energies inferred from the radar electron density profiles, from the N 2 + rotational temperature and the I(6300)/I(4278) ratio were in good agreement. The variation of the I(8446)/I(4278) ratio was studies and was found to be promising as an index of average incident electron energy. An empirical relation between this ratio and average energy was derived from the data. The observed values of I(4278) exceeded the theoretical values derived from the ionization rate profiles deduced from the radar data by a factor near 2.0. Observed electron density profiles and theoretical profiles calculated from optical data were in good agreement provided that the optically inferred ion production rates were reduced by the same factor of 2. This discrepancy is probably the cumulative result of small errors in instrument calibrations, viewing geometry, recombination coefficients and the excitation and ionization cross sections used in the model

  19. Fourth Order Nonlinear Intensity and the corresponding Refractive ...

    African Journals Online (AJOL)

    Nonlinear effects occur whenever the optical fields associated with one or more intense light such as from laser beams propagating in a crystal are large enough to produce polarization fields. This paper describes how the fourth order nonlinear intensity and the corresponding effective refractive index that is intensity ...

  20. Optical transition radiation interferometry for A0 photoinjector

    International Nuclear Information System (INIS)

    Kazakevich, G.; Novosibirsk, IYF; Edwards, H.; Fliller, R.; Lebedev, V.; Nagaitsev, S.; Santucci, J.; Thurman-Keup, R.; Fermilab; Piot, P.; Fermilab; Northern Illinois U.; Li, J.; Tikhoplav, R.; UCLA

    2007-01-01

    A charged particle passing through the boundary of two medias with different permittivity values generates Transition Radiation (TR), [1]. The TR is caused by a variation of the particle electric field with variation of the permittivity. The TR for relativistic particles has a wide spectrum with a significant portion in the optical range. The Optical Transition Radiation (OTR) is widely used for a beam profile monitoring and measurements of a beam size. Moreover, OTR can be used to characterize the energy, energy spread and transverse angles in the beam by employing the interference of the OTR from two thin films [2] inserted in the beam trajectory. This method has been applied in number of works [3-5] demonstrating high results and good coincidence in measurements and calculations. In this paper we present and discuss in details a simulation of the interference pattern in several experimental setups. We consider the main optical effects, for diagnostics for the beam properties at A0 Photoinjector and the ILC module test area (NML) in a wide range of electron beam energy. In this paper, we first derive the OTR intensity formula for a single film at 90 degrees to the beam, then for two films at normal incidence, and finally with films at 45 degree incidence to the beam. The last section illustrates application with beam parameters like those at the A0 Photoinjector (electron energy 15 MeV)

  1. New generation of optical fibres

    Energy Technology Data Exchange (ETDEWEB)

    Dianov, E M; Semjonov, S L; Bufetov, I A [Fiber Optics Research Center, Russian Academy of Sciences, Moscow (Russian Federation)

    2016-01-31

    The growing need for information in contemporary society is the motivating force behind the development of fibre optics in general and optical fibre communications in particular. Intensive research effort has been concentrated on designing new types of optical fibres and extending their application field. This paper reviews results of research on new types of optical fibres: bismuthdoped active fibres, multicore fibres and hollow-core fibres, which can be used as key components of systems that ensure further increase in optical information transfer rate. (invited paper)

  2. Intensive Care Unit Delirium

    Directory of Open Access Journals (Sweden)

    Yongsuk Kim

    2015-05-01

    Full Text Available Delirium is described as a manifestation of acute brain injury and recognized as one of the most common complications in intensive care unit (ICU patients. Although the causes of delirium vary widely among patients, delirium increases the risk of longer ICU and hospital length of stay, death, cost of care, and post-ICU cognitive impairment. Prevention and early detection are therefore crucial. However, the clinical approach toward delirium is not sufficiently aggressive, despite the condition’s high incidence and prevalence in the ICU setting. While the underlying pathophysiology of delirium is not fully understood, many risk factors have been suggested. As a way to improve delirium-related clinical outcome, high-risk patients can be identified. A valid and reliable bedside screening tool is also needed to detect the symptoms of delirium early. Delirium is commonly treated with medications, and haloperidol and atypical antipsychotics are commonly used as standard treatment options for ICU patients although their efficacy and safety have not been established. The approaches for the treatment of delirium should focus on identifying the underlying causes and reducing modifiable risk factors to promote early mobilization.

  3. Lightning incidents in Mongolia

    Directory of Open Access Journals (Sweden)

    Myagmar Doljinsuren

    2015-11-01

    Full Text Available This is one of the first studies that has been conducted in Mongolia on the distribution of lightning incidents. The study covers a 10-year period from 2004 to 2013. The country records a human death rate of 15.4 deaths per 10 million people per year, which is much higher than that of many countries with similar isokeraunic level. The reason may be the low-grown vegetation observed in most rural areas of Mongolia, a surface topography, typical to steppe climate. We suggest modifications to Gomes–Kadir equation for such countries, as it predicts a much lower annual death rate for Mongolia. The lightning incidents spread over the period from May to August with the peak of the number of incidents occurring in July. The worst lightning affected region in the country is the central part. Compared with impacts of other convective disasters such as squalls, thunderstorms and hail, lightning stands as the second highest in the number of incidents, human deaths and animal deaths. Economic losses due to lightning is only about 1% of the total losses due to the four extreme weather phenomena. However, unless precautionary measures are not promoted among the public, this figure of losses may significantly increase with time as the country is undergoing rapid industrialization at present.

  4. Incident users of antipsychotics

    DEFF Research Database (Denmark)

    Baandrup, Lone; Kruse, Marie

    2016-01-01

    PURPOSE: In Denmark, as well as in many other countries, consumption of antipsychotics is on the rise, partly due to increasing off-label use. The aim of this study was to analyze and quantify the extent of off-label use and polypharmacy in incident users of antipsychotic medication, and to examine...

  5. Novel method of optical image registration in wide wavelength range using matrix of piezoelectric crystals

    Science.gov (United States)

    Pigarev, Aleksey V.; Bazarov, Timur O.; Fedorov, Vladimir V.; Ryabushkin, Oleg A.

    2018-02-01

    Most modern systems of the optical image registration are based on the matrices of photosensitive semiconductor heterostructures. However, measurement of radiation intensities up to several MW/cm2 -level using such detectors is a great challenge because semiconductor elements have low optical damage threshold. Reflecting or absorbing filters that can be used for attenuation of radiation intensity, as a rule, distort beam profile. Furthermore, semiconductor based devices have relatively narrow measurement wavelength bandwidth. We introduce a novel matrix method of optical image registration. This approach doesn't require any attenuation when measuring high radiation intensities. A sensitive element is the matrix made of thin transparent piezoelectric crystals that absorb just a small part of incident optical power. Each crystal element has its own set of intrinsic (acoustic) vibration modes. These modes can be exited due to the inverse piezoelectric effect when the external electric field is applied to the crystal sample providing that the field frequency corresponds to one of the vibration mode frequencies. Such piezoelectric resonances (PR) can be observed by measuring the radiofrequency response spectrum of the crystal placed between the capacitor plates. PR frequencies strongly depend on the crystal temperature. Temperature calibration of PR frequencies is conducted in the uniform heating conditions. In the case a crystal matrix is exposed to the laser radiation the incident power can be obtained separately for each crystal element by measuring its PR frequency kinetics providing that the optical absorption coefficient is known. The operating wavelength range of such sensor is restricted by the transmission bandwidth of the applied crystals. A plane matrix constituting of LiNbO3 crystals was assembled in order to demonstrate the possibility of application of the proposed approach. The crystal elements were placed between two electrodes forming a capacitor which

  6. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... 45 David, Age 65 Harold, Age 67 Data & Statistics Facts About Physical Activity Data, Trends and Maps ... relative intensity and absolute intensity. Relative Intensity The level of effort required by a person to do ...

  7. Incident spectrum determination for time-of-flight neutron powder diffraction data analysis

    International Nuclear Information System (INIS)

    Hodges, J. P.

    1998-01-01

    Accurate characterization of the incident neutron spectrum is an important requirement for precise Rietveld analysis of time-of-flight powder neutron diffraction data. Without an accurate incident spectrum the calculated model for the measured relative intensities of individual Bragg reflections will possess systematic errors. We describe a method for obtaining an accurate numerical incident spectrum using data from a transmitted beam monitor

  8. Fibre-optic temperature sensor

    International Nuclear Information System (INIS)

    Zhao Jie; Liu Zhenyuan.

    1993-04-01

    This experiment is a kind of nonfunction fibre-optic temperature sensor. It utilizes high-sensitive bimetallic strip for element of measuring temperature. The changing of bimetallic strip alterates intensity of light through fibre-optic. This equipment is simple in structure, subtle in design, extensive in application, and so on. (author). 4 refs, 6 figs, 1 tab

  9. Incident laser modulation of a repaired damage site with a rim in fused silica rear subsurface

    Institute of Scientific and Technical Information of China (English)

    Li Li; Xiang Xia; Zu Xiao-Tao; Yuan Xiao-Dong; He Shao-Bo; Jiang Xiao-Dong; Zheng Wan-Guo

    2012-01-01

    Local CO2 laser treatment has proved to be an effective method to prevent the 351-nm laser-induced damage sitesin a fused silica surface from exponentially growing,which is responsible for limiting the lifetime of optics in high fluence laser systems.However,the CO2 laser induced ablation crater is often surrounded by a raised rim at the edge,which can also result in the intensification of transmitted ultraviolet light that may damage the downstream optics.In this work,the three-dimensional finite-difference time-domain method is developed to simulate the distribution of electrical field intensity in the vicinity of the CO2 laser mitigated damage site located in the exit subsurface of fused silica.The simulated results show that the repaired damage sites with raised rims cause more notable modulation to the incident laser than those without rims.Specifically,we present a theoretical model of using dimpled patterning to control the rim structure around the edge of repaired damage sites to avoid damage to downstream optics.The calculated results accord well with previous experimental results and the underlying physical mechanism is analysed in detail.

  10. Reflection and transmission of normally incident full-vector X waves on planar interfaces

    KAUST Repository

    Salem, Mohamed

    2011-12-23

    The reflection and transmission of full-vector X waves normally incident on planar half-spaces and slabs are studied. For this purpose, X waves are expanded in terms of weighted vector Bessel beams; this new decomposition and reconstruction method offers a more lucid and intuitive interpretation of the physical phenomena observed upon the reflection or transmission of X waves when compared to the conventional plane-wave decomposition technique. Using the Bessel beam expansion approach, we have characterized changes in the field shape and the intensity distribution of the transmitted and reflected full-vector X waves. We have also identified a novel longitudinal shift, which is observed when a full-vector X wave is transmitted through a dielectric slab under frustrated total reflection condition. The results of our studies presented here are valuable in understanding the behavior of full-vector X waves when they are utilized in practical applications in electromagnetics, optics, and photonics, such as trap and tweezer setups, optical lithography, and immaterial probing. © 2011 Optical Society of America.

  11. Incidents with hazardous radiation sources

    International Nuclear Information System (INIS)

    Schoenhacker, Stefan

    2016-01-01

    Incidents with hazardous radiation sources can occur in any country, even those without nuclear facilities. Preparedness for such incidents is supposed to fulfill globally agreed minimum standards. Incidents are categorized in incidents with licensed handling of radiation sources as for material testing, transport accidents of hazardous radiation sources, incidents with radionuclide batteries, incidents with satellites containing radioactive inventory, incidents wit not licensed handling of illegally acquired hazardous radiation sources. The emergency planning in Austria includes a differentiation according to the consequences: incidents with release of radioactive materials resulting in restricted contamination, incidents with release of radioactive materials resulting in local contamination, and incidents with the hazard of e@nhanced exposure due to the radiation source.

  12. Optical supercavitation in soft matter.

    Science.gov (United States)

    Conti, C; DelRe, E

    2010-09-10

    We investigate theoretically, numerically, and experimentally nonlinear optical waves in an absorbing out-of-equilibrium colloidal material at the gelification transition. At a sufficiently high optical intensity, absorption is frustrated and light propagates into the medium. The process is mediated by the formation of a matter-shock wave due to optically induced thermodiffusion and largely resembles the mechanism of hydrodynamical supercavitation, as it is accompanied by a dynamic phase-transition region between the beam and the absorbing material.

  13. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2005-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  14. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2000-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  15. Solitonic guides in photopolymerizable materials for optical devices

    Science.gov (United States)

    Dorkenoo, Kokou D.; Cregut, Olivier; Fort, Alain

    2003-11-01

    These last twenty years, advanced studies in integrated optics have demonstrated the capacity to elaborate optical circuits in planar substrates. Most of the optical integrated devices are realized on glass substrate and the guide areas are usually obtained by photolithography techniques. We present here a new approach based on the use of compounds photopolymerizable in the visible range. The conditions of self written channel creation by solitonic propagation inside the bulk of the photopolymerizable formulation are analyzed. Waveguides can be self-written in photopolymerizable materials1,2 due to the dependence of their refractive index on intensity and duration of the active light. This process results from the competition between the diffraction of the incident Gaussian beam and the photopolymerization which tends to increase the refractive index where light intensity is the highest. By controlling the difference between the refractive index values of the polymerized and non polymerized zones, the beam can be self-trapped along the propagation axis giving rise to a waveguide over distances as large as 10 cm without any broadening. Such permanent waveguides can be structured by inscription of gratings and doped with a dye in a plastic cell leading to the elaboration of a completely plastic laser.

  16. Optical readout method for solid-state dosemeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Eichner, F.N.; Stahl, K.A.; Miller, S.D.

    1986-07-01

    The readout of solid-state dosemeters is usually accomplished by heating to produce thermoluminescence. This technique has several disadvantages including stressing the dosemeter crystals, melting Teflon enclosures, and destroying the thin dosemeters designed for beta particle measurements. An optical readout method is being developed to avoid these difficulties. Standard dosemeters were irradiated to a dose of approximately 0.02 Sv with 137 Cs gamma rays. The dosemeters were then irradiated with light produced by a high-intensity xenon lamp. Various wavelength bands, from the ultraviolet through the visible and to the near-infrared, were used. The degree of trap emptying was found to be proportional to the total optical power incident. With the intensities used in the preliminary experiments, over 90% trap emptying was achieved. This new technique will prove useful for dosemeters that are encased in plastic for automatic processing. The details of this optical readout method, along with some possible applications in neutron and beta dosimetry are described. 7 refs., 3 figs

  17. Solid state optical microscope

    Science.gov (United States)

    Young, Ian T.

    1983-01-01

    A solid state optical microscope wherein wide-field and high-resolution images of an object are produced at a rapid rate by utilizing conventional optics with a charge-coupled photodiode array. A galvanometer scanning mirror, for scanning in one of two orthogonal directions is provided, while the charge-coupled photodiode array scans in the other orthogonal direction. Illumination light from the object is incident upon the photodiodes, creating packets of electrons (signals) which are representative of the illuminated object. The signals are then processed, stored in a memory, and finally displayed as a video signal.

  18. Optical properties of Amorphous Semiconductors Part- II: Theory and analysis of optical properties

    International Nuclear Information System (INIS)

    Hogarth, C. A.

    1997-01-01

    The atomic and band structural properties of solids have been studied. Reflectance is concerned in spectroscopic measurement of transmission and absorption, since the incident light intensity must be corrected for the loss of light by reflection and which does not penetrate beyond the surface of the material studied.The procedure for estimating E opt and n from the absorption edge of an amorphous semiconductor has been discussed. In high refractive index glasses there is a general correlation between n and the density of the glasses and in designing a particular glass for an optical purpose this can provide a useful guide to composition. The Gladstone-Dale refractivity and the Newton-Drude refractivity have been calculated for different value of b and these relations have been tested for telluride semiconducting glasses and give reasonable agreement in estimations of n directly from the density ρ. 33 refs., 10 figs

  19. Maximum Credible Incidents

    CERN Document Server

    Strait, J

    2009-01-01

    Following the incident in sector 34, considerable effort has been made to improve the systems for detecting similar faults and to improve the safety systems to limit the damage if a similar incident should occur. Nevertheless, even after the consolidation and repairs are completed, other faults may still occur in the superconducting magnet systems, which could result in damage to the LHC. Such faults include both direct failures of a particular component or system, or an incorrect response to a “normal” upset condition, for example a quench. I will review a range of faults which could be reasonably expected to occur in the superconducting magnet systems, and which could result in substantial damage and down-time to the LHC. I will evaluate the probability and the consequences of such faults, and suggest what mitigations, if any, are possible to protect against each.

  20. Contaminated Mexican steel incident

    International Nuclear Information System (INIS)

    1985-01-01

    This report documents the circumstances contributing to the inadvertent melting of cobalt 60 (Co-60) contaminated scrap metal in two Mexican steel foundries and the subsequent distribution of contaminated steel products into the United States. The report addresses mainly those actions taken by US Federal and state agencies to protect the US population from radiation risks associated with the incident. Mexico had much more serious radiation exposure and contamination problems to manage. The United States Government maintained a standing offer to provide technical and medical assistance to the Mexican Government. The report covers the tracing of the source to its origin, response actions to recover radioactive steel in the United States, and return of the contaminated materials to Mexico. The incident resulted in significant radiation exposures within Mexico, but no known significant exposure within the United States. Response to the incident required the combined efforts of the Nuclear Regulatory Commission (NRC), Department of Energy, Department of Transportation, Department of State, and US Customs Service (Department of Treasury) personnel at the Federal level and representatives of all 50 State Radiation Control Programs and, in some instances, local and county government personnel. The response also required a diplomatic interface with the Mexican Government and cooperation of numerous commercial establishments and members of the general public. The report describes the factual information associated with the event and may serve as information for subsequent recommendations and actions by the NRC. 8 figures

  1. Physical optics

    International Nuclear Information System (INIS)

    Kim Il Gon; Lee, Seong Su; Jang, Gi Wan

    2012-07-01

    This book indicates physical optics with properties and transmission of light, mathematical expression of wave like harmonic wave and cylindrical wave, electromagnetic theory and light, transmission of light with Fermat principle and Fresnel equation, geometrical optics I, geometrical optics II, optical instrument such as stops, glasses and camera, polarized light like double refraction by polarized light, interference, interference by multiple reflections, diffraction, solid optics, crystal optics such as Faraday rotation and Kerr effect and measurement of light. Each chapter has an exercise.

  2. Physical optics

    Energy Technology Data Exchange (ETDEWEB)

    Kim Il Gon; Lee, Seong Su; Jang, Gi Wan

    2012-07-15

    This book indicates physical optics with properties and transmission of light, mathematical expression of wave like harmonic wave and cylindrical wave, electromagnetic theory and light, transmission of light with Fermat principle and Fresnel equation, geometrical optics I, geometrical optics II, optical instrument such as stops, glasses and camera, polarized light like double refraction by polarized light, interference, interference by multiple reflections, diffraction, solid optics, crystal optics such as Faraday rotation and Kerr effect and measurement of light. Each chapter has an exercise.

  3. Quantum optics

    National Research Council Canada - National Science Library

    Agarwal, G. S

    2013-01-01

    .... Focusing on applications of quantum optics, the textbook covers recent developments such as engineering of quantum states, quantum optics on a chip, nano-mechanical mirrors, quantum entanglement...

  4. Switching waves dynamics in optical bistable cavity-free system at femtosecond laser pulse propagation in semiconductor under light diffraction

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Egorenkov, Vladimir A.; Loginova, Maria M.

    2018-02-01

    We consider a propagation of laser pulse in a semiconductor under the conditions of an occurrence of optical bistability, which appears due to a nonlinear absorption of the semiconductor. As a result, the domains of high concentration of free charged particles (electrons and ionized donors) occur if an intensity of the incident optical pulse is greater than certain intensity. As it is well-known, that an optical beam must undergo a diffraction on (or reflection from) the domains boundaries. Usually, the beam diffraction along a coordinate of the optical pulse propagation does not take into account by using the slowly varying envelope approximation for the laser pulse interaction with optical bistable element. Therefore, a reflection of the beam from the domains with abrupt boundary does not take into account under computer simulation of the laser pulse propagation. However, the optical beams, reflected from nonhomogeneities caused by the domains of high concentration of free-charged particles, can essentially influence on a formation of switching waves in a semiconductor. We illustrate this statement by computer simulation results provided on the base of nonlinear Schrödinger equation and a set of PDEs, which describe an evolution of the semiconductor characteristics (concentrations of free-charged particles and potential of an electric field strength), and taking into account the longitudinal and transverse diffraction effects.

  5. Plasmas produced by incident laser in solids

    International Nuclear Information System (INIS)

    Oliveira Campos, D. de; Boeckelmann, H.K.

    1984-01-01

    The experimental arrangement for plasma production by incident laser in solids and a system of diagnostics are presented. The system of diagnostics allows: verify the plasma generation and expansion through the ultrahigh-speed photography; obtain measurements of temperature and density by spectroscopy (using an optical analyser of multichannels) and obtain measurements of kinetic energy of ions through his fly time, using a 'Faraday cup'. A vacuum system with an adsorption pump for pre-vacuum and ionic pump was used to reduce pressure and avoid mechanical vibrations and system contaminations. (M.C.K.) [pt

  6. Increased Incidence of Critical Illness in Psoriasis.

    Science.gov (United States)

    Marrie, Ruth Ann; Bernstein, Charles N; Peschken, Christine A; Hitchon, Carol A; Chen, Hui; Garland, Allan

    Psoriasis is associated with an increased risk of comorbid disease. Despite the recognition of increased morbidity in psoriasis, the effects on health care utilisation remain incompletely understood. Little is known about the risk of intensive care unit (ICU) admission in persons with psoriasis. To compare the incidence of ICU admission and post-ICU mortality rates in a psoriasis population compared with a matched population without psoriasis. Using population-based administrative data from Manitoba, Canada, we identified 40 930 prevalent cases of psoriasis and an age-, sex-, and geographically matched cohort from the general population (n = 150 210). We compared the incidence of ICU admission between populations using incidence rates and Cox regression models adjusted for age, sex, socioeconomic status, and comorbidity and compared mortality after ICU admission. Among incident psoriasis cases (n = 30 150), the cumulative 10-year incidence of ICU admission was 5.6% (95% confidence interval [CI], 5.3%-5.8%), 21% higher than in the matched cohort (incidence rate ratio, 1.21; 95% CI, 1.15-1.27). In the prevalent psoriasis cohort, crude mortality in the ICU was 11.5% (95% CI, 9.9%-13.0%), 32% higher than observed in the matched population admitted to the ICU (8.7%; 95% CI, 8.3%-9.1%). Mortality rates after ICU admission remained elevated at all time points in the psoriasis cohort compared with the matched cohort. Psoriasis is associated with an increased risk for ICU admission and with an increased risk of mortality post-ICU admission.

  7. Medication incidents reported to an online incident reporting system.

    LENUS (Irish Health Repository)

    Alrwisan, Adel

    2011-01-15

    AIMS: Approximately 20% of deaths from adverse events are related to medication incidents, costing the NHS an additional £500 million annually. Less than 5% of adverse events are reported. This study aims to assess the reporting rate of medication incidents in NHS facilities in the north east of Scotland, and to describe the types and outcomes of reported incidents among different services. Furthermore, we wished to quantify the proportion of reported incidents according to the reporters\\' profession. METHODS: A retrospective description was made of medication incidents reported to an online reporting system (DATIX) over a 46-month-period (July 2005 to April 2009). Reports originated from acute and community hospitals, mental health, and primary care facilities. RESULTS: Over the study period there were 2,666 incidents reported with a mean monthly reporting rate of 78.2\\/month (SD±16.9). 6.1% of all incidents resulted in harm, with insulin being the most commonly implicated medication. Nearly three-quarters (74.2%, n=1,978) of total incidents originated from acute hospitals. Administration incidents were implicated in the majority of the reported medication incidents (59%), followed by prescribing (10.8%) and dispensing (9.9%), while the nondescript "other medication incidents" accounted for 20.3% of total incidents. The majority of reports were made by nursing and midwifery staff (80%), with medical and dental professionals reporting the lowest number of incidents (n=56, 2%). CONCLUSIONS: The majority of medication incidents in this study were reported by nursing and midwifery staff, and were due to administration incidents. There is a clear need to elucidate the reasons for the limited contribution of the medical and dental professionals to reporting medication incidents.

  8. Astronomical optics and elasticity theory

    CERN Document Server

    Lemaitre, Gerard Rene

    2008-01-01

    Astronomical Optics and Elasticity Theory provides a very thorough and comprehensive account of what is known in this field. After an extensive introduction to optics and elasticity, the book discusses variable curvature and multimode deformable mirrors, as well as, in depth, active optics, its theory and applications. Further, optical design utilizing the Schmidt concept and various types of Schmidt correctors, as well as the elasticity theory of thin plates and shells are elaborated upon. Several active optics methods are developed for obtaining aberration corrected diffraction gratings. Further, a weakly conical shell theory of elasticity is elaborated for the aspherization of grazing incidence telescope mirrors. The very didactic and fairly easy-to-read presentation of the topic will enable PhD students and young researchers to actively participate in challenging astronomical optics and instrumentation projects.

  9. Two mode optical fiber in space optics communication

    Science.gov (United States)

    Hampl, Martin

    2017-11-01

    In our contribution we propose to use of a two-mode optical fiber as a primary source in a transmitting optical head instead of the laser diode. The distribution of the optical intensity and the complex degree of the coherence on the output aperture of the lens that is irradiated by a step-index weakly guiding optical fiber is investigated. In our treatment we take into account weakly guided modes with polarization corrections to the propagation constant and unified theory of second order coherence and polarization of electromagnetic beams.

  10. Deuteron microscopic optical model potential

    International Nuclear Information System (INIS)

    Guo Hairui; Han Yinlu; Shen Qingbiao; Xu Yongli

    2010-01-01

    A deuteron microscopic optical model potential is obtained by the Green function method through nuclear-matter approximation and local-density approximation based on the effective Skyrme interaction. The microscopic optical model potential is used to calculate the deuteron reaction cross sections and the elastic scattering angular distributions for some target nuclei in the mass range 6≤A≤208 with incident deuteron energies up to 200 MeV. The calculated results are compared with the experimental data.

  11. Prevalence Incidence Mixture Models

    Science.gov (United States)

    The R package and webtool fits Prevalence Incidence Mixture models to left-censored and irregularly interval-censored time to event data that is commonly found in screening cohorts assembled from electronic health records. Absolute and relative risk can be estimated for simple random sampling, and stratified sampling (the two approaches of superpopulation and a finite population are supported for target populations). Non-parametric (absolute risks only), semi-parametric, weakly-parametric (using B-splines), and some fully parametric (such as the logistic-Weibull) models are supported.

  12. Optical and magneto-optical characterization of TbFeCo thin films in trilayer structures

    International Nuclear Information System (INIS)

    McGahan, W.A.; He, P.; Chen, L.; Bonafede, S.; Woollam, J.A.; Sequeda, F.; McDaniel, T.; Do, H.

    1991-01-01

    A series of TbFeCo films ranging in thickness from 100 to 800 A have been deposited in trilayer structures on silicon wafer substrates, with Si 3 N 4 being employed as the dielectric material. These films have been characterized both optically and magneto-optically by variable angle of incidence spectroscopic ellipsometry, normal angle of incidence reflectometry, and normal angle of incidence Kerr spectroscopy. From these measurements, the optical constants n and k have been determined for the TbFeCo films, as well as the magneto-optical constants Q1 and Q2. Results are presented that demonstrate the lack of dependence of these constants on the thickness of the TbFeCo film, and which can be used for calculating the expected optical and magneto-optical response of any multilayer structure containing similar TbFeCo films

  13. Compact, low-cost, and high-resolution interrogation unit for optical sensors

    International Nuclear Information System (INIS)

    Kiesel, Peter; Schmidt, Oliver; Mohta, Setu; Johnson, Noble; Malzer, Stefan

    2006-01-01

    Compact wavelength detectors that resolve wavelength changes in the subpicometer range over a broad spectral range are presented. A photodiode array or position sensor device is coated with a linear variable filter that converts the wavelength of the incident light into a spatial intensity distribution. The centroid of the spatial distribution is determined by a differential readout of the two elements of the photodiode array or the position sensor device. The device can interrogate any optical sensor that produces a wavelength shift in response to a stimulus. The potential of this device was tested by interrogating fiber-Bragg-grating sensors

  14. Microchip Flow Cytometer with Integrated Polymer Optical Elements for Measurement of Scattered Light

    DEFF Research Database (Denmark)

    Wang, Zhenyu; El-Ali, Jamil; Perch-Nielsen, Ivan Ryberg

    2004-01-01

    channels to form a complete microchip flow cytometer. All the optical elements, the microfluidic system, and the fiber-to-waveguide couplers were defined in one layer of polymer (SU-8, negative photoresist) by standard photolithography. With only one single mask procedure, all the fabrication and packaging...... processes can be finished in one day. Polystyrene beads were measured in the microchip flow cytometer, and three signals (forward scattering, large angle scattering and extinction) were measured simultaneously for each bead. The average intensities of the forward Scattered light and the incident light...

  15. Improving freight crash incident management.

    Science.gov (United States)

    2015-06-01

    The objective of this study was to determine the most effective way to mitigate the effect of freight : crash incidents on Louisiana freeways. Candidate incident management strategies were reviewed from : practice in other states and from those publi...

  16. Increasing incidence of pyogenic spondylodiscitis

    DEFF Research Database (Denmark)

    Kehrer, Michala; Pedersen, Court; Jensen, Thøger G

    2014-01-01

    Smaller studies indicate that the incidence of pyogenic spondylodiscitis is increasing, possible related to a growing elderly population. Data supporting this is sparse, and we therefore studied patient characteristics and changes in spondylodiscitis incidence 1995-2008.......Smaller studies indicate that the incidence of pyogenic spondylodiscitis is increasing, possible related to a growing elderly population. Data supporting this is sparse, and we therefore studied patient characteristics and changes in spondylodiscitis incidence 1995-2008....

  17. Dispersion measurement on chirped mirrors at arbitrary incidence angle and polarization state (Conference Presentation)

    Science.gov (United States)

    Kovacs, Mate; Somoskoi, Tamas; Seres, Imre; Borzsonyi, Adam; Sipos, Aron; Osvay, Károly

    2017-05-01

    The optical elements of femtosecond high peak power lasers have to fulfill more and more strict requirements in order to support pulses with high intensity and broad spectrum. In most cases chirped pulse amplification scheme is used to generate high peak power ultrashort laser pulses, where a very precise control of spectral intensity and spectral phase is required in reaching transform-limited temporal shape at the output. In the case of few cycle regime, the conventional bulk glass, prism-, grating- and their combination based compressors are not sufficient anymore, due to undesirable nonlinear effects in their material and proneness to optical damages. The chirped mirrors are also commonly used to complete the compression after a beam transport system just before the target. Moreover, the manufacturing technology requires quality checks right after production and over the lifetime of the mirror as well, since undesired deposition on the surface can lead alteration from the designed value over a large part of the aperture. For the high harmonic generation, polarization gating technology is used to generate single attosecond pulses [1]. In this case the pulse to be compressed has various polarization state falling to the chirped mirrors. For this reason, it is crucial to measure the dispersion of the mirrors for the different polarization states. In this presentation we demonstrate a simple technique to measure the dispersion of arbitrary mirror at angles of incidence from 0 to 55 degree, even for a 12" optics. A large aperture 4" mirror has been scanned over with micrometer accuracy and the dispersion property through the surface has been investigated with a stable interference fringes in that robust geometry. We used Spectrally Resolved Interferometry, which is based on a Michaelson interferometer and a combined visible and infrared spectrometer. Tungsten halogen lamp with 10 mW coupled optical power was used as a white-light source so with the selected

  18. Optical traps with geometric aberrations

    International Nuclear Information System (INIS)

    Roichman, Yael; Waldron, Alex; Gardel, Emily; Grier, David G.

    2006-01-01

    We assess the influence of geometric aberrations on the in-plane performance of optical traps by studying the dynamics of trapped colloidal spheres in deliberately distorted holographic optical tweezers. The lateral stiffness of the traps turns out to be insensitive to moderate amounts of coma, astigmatism, and spherical aberration. Moreover holographic aberration correction enables us to compensate inherent shortcomings in the optical train, thereby adaptively improving its performance. We also demonstrate the effects of geometric aberrations on the intensity profiles of optical vortices, whose readily measured deformations suggest a method for rapidly estimating and correcting geometric aberrations in holographic trapping systems

  19. Incident Management: Process into Practice

    Science.gov (United States)

    Isaac, Gayle; Moore, Brian

    2011-01-01

    Tornados, shootings, fires--these are emergencies that require fast action by school district personnel, but they are not the only incidents that require risk management. The authors have introduced the National Incident Management System (NIMS) and the Incident Command System (ICS) and assured that these systems can help educators plan for and…

  20. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    Energy Technology Data Exchange (ETDEWEB)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C. [Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy); Gupta, A. [Department of Chemistry, University of Alabama, Tuscaloosa, Alabama 35487 (United States); Carpene, E., E-mail: ettore.carpene@polimi.it [CNR-IFN, Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO{sub 2} single crystals as a benchmark.

  1. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    International Nuclear Information System (INIS)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C.; Gupta, A.; Carpene, E.

    2015-01-01

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO 2 single crystals as a benchmark

  2. Optical Computing

    OpenAIRE

    Woods, Damien; Naughton, Thomas J.

    2008-01-01

    We consider optical computers that encode data using images and compute by transforming such images. We give an overview of a number of such optical computing architectures, including descriptions of the type of hardware commonly used in optical computing, as well as some of the computational efficiencies of optical devices. We go on to discuss optical computing from the point of view of computational complexity theory, with the aim of putting some old, and some very recent, re...

  3. Film thickness determination by grazing incidence diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Battiston, G A; Gerbasi, R [CNR, Padua (Italy). Istituto di Chimica e Tecnologie Inorganiche e dei Materiali Avanzati

    1996-09-01

    Thin films deposited via MOCVD (Metal Organic Chemical Vapour Deposition) are layers in the thickness range of a few manometers to about ten micrometers. An understanding of the physics and chemistry of films is necessary for a better comprehension of the phenomena involved in the film deposition procedure and its optimisation. Together with the crystalline phase a parameter that must be determined is the thickness of the layer. In this work the authors present a method for the measurement of the film thickness. This procedure, based on diffraction intensity absorption of the X-rays, both incident and diffracted in passing through the layers, resulted quite simple, rapid and non-destructive.

  4. Film thickness determination by grazing incidence diffraction

    International Nuclear Information System (INIS)

    Battiston, G. A.; Gerbasi, R.

    1996-01-01

    Thin films deposited via MOCVD (Metal Organic Chemical Vapour Deposition) are layers in the thickness range of a few manometers to about ten micrometers. An understanding of the physics and chemistry of films is necessary for a better comprehension of the phenomena involved in the film deposition procedure and its optimisation. Together with the crystalline phase a parameter that must be determined is the thickness of the layer. In this work the authors present a method for the measurement of the film thickness. This procedure, based on diffraction intensity absorption of the X-rays, both incident and diffracted in passing through the layers, resulted quite simple, rapid and non-destructive

  5. Radiation produced by electrons incident on molecules

    International Nuclear Information System (INIS)

    Moehlman, G.R.

    1977-01-01

    The work described in this thesis deals with light intensity measurements of emission spectra (1850-9000 A) produced by a continuous or pulsed beam of monoenergetic electrons (0 - 2000 eV) incident on a variety of molecular gases like H 2 , D 2 , H 2 O, HCl, NH 3 and several hydrocarbons. The emission spectra are dominated by fluorescence from excited fragments produced via dissociative excitation, besides fluorescence from excited parent molecules themselves. The experimental results thus obtained are expressed in terms of emission cross sections and lifetimes

  6. Fluorescent optical position sensor

    Science.gov (United States)

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  7. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... using relative intensity, people pay attention to how physical activity affects their heart rate and breathing. The talk test is a simple way to measure relative intensity. ...

  8. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart Rate & Estimated Maximum Heart Rate Perceived Exertion ( ... a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived ...

  9. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Share Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, ... The table below lists examples of activities classified as moderate-intensity or vigorous-intensity based upon the ...

  10. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... for a breath. Absolute Intensity The amount of energy used by the body per minute of activity. ... or vigorous-intensity based upon the amount of energy used by the body while doing the activity. ...

  11. Iowa Intensive Archaeological Survey

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This shape file contains intensive level archaeological survey areas for the state of Iowa. All intensive Phase I surveys that are submitted to the State Historic...

  12. The Holy Grail of quantum optical communication

    International Nuclear Information System (INIS)

    García-Patrón, Raúl; Navarrete-Benlloch, Carlos; Lloyd, Seth; Shapiro, Jeffrey H.; Cerf, Nicolas J.

    2014-01-01

    Optical parametric amplifiers together with phase-shifters and beamsplitters have certainly been the most studied objects in the field of quantum optics. Despite such an intensive study, optical parametric amplifiers still keep secrets from us. We will show how they hold the answer to one of the oldest problems in quantum communication theory, namely the calculation of the optimal communication rate of optical channels

  13. Rainfed intensive crop systems

    DEFF Research Database (Denmark)

    Olesen, Jørgen E

    2014-01-01

    This chapter focuses on the importance of intensive cropping systems in contributing to the world supply of food and feed. The impact of climate change on intensive crop production systems is also discussed.......This chapter focuses on the importance of intensive cropping systems in contributing to the world supply of food and feed. The impact of climate change on intensive crop production systems is also discussed....

  14. Optically switchable photonic metasurfaces

    Energy Technology Data Exchange (ETDEWEB)

    Waters, R. F.; MacDonald, K. F. [Centre for Photonic Metamaterials and Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ (United Kingdom); Hobson, P. A. [QinetiQ Ltd., Cody Technology Park, Farnborough, Hampshire GU14 0LX (United Kingdom); Zheludev, N. I. [Centre for Photonic Metamaterials and Optoelectronics Research Centre, University of Southampton, Southampton SO17 1BJ (United Kingdom); Centre for Disruptive Photonic Technologies and The Photonics Institute, Nanyang Technological University, Singapore 637371 (Singapore)

    2015-08-24

    We experimentally demonstrate an optically switchable gallium-based metasurface, in which a reversible light-induced transition between solid and liquid phases occurring in a confined nanoscale surface layer of the metal drives significant changes in reflectivity and absorption. The metasurface architecture resonantly enhances the metal's “active plasmonic” phase-change nonlinearity by an order of magnitude, offering high contrast all-optical switching in the near-infrared range at low, μW μm{sup −2}, excitation intensities.

  15. Method and apparatus for bistable optical information storage for erasable optical disks

    Science.gov (United States)

    Land, Cecil E.; McKinney, Ira D.

    1990-01-01

    A method and an optical device for bistable storage of optical information, together with reading and erasure of the optical information, using a photoactivated shift in a field dependent phase transition between a metastable or a bias-stabilized ferroelectric (FE) phase and a stable antiferroelectric (AFE) phase in an lead lanthanum zirconate titanate (PLZT). An optical disk contains the PLZT. Writing and erasing of optical information can be accomplished by a light beam normal to the disk. Reading of optical information can be accomplished by a light beam at an incidence angle of 15 to 60 degrees to the normal of the disk.

  16. The structural and optical characterizations of tetraphenylporphyrin thin films

    Energy Technology Data Exchange (ETDEWEB)

    Makhlouf, M.M., E-mail: m_makhlof@hotmail.com [Physics Department, Faculty of Applied Medical Science at Turabah branch, Taif University, Turabah, 21995 (Saudi Arabia); Department of Physics, Faculty of Science at New Damietta, Damietta University, New Damietta 34517 (Egypt); El-Denglawey, A. [Physics Department, Faculty of Applied Medical Science at Turabah branch, Taif University, Turabah, 21995 (Saudi Arabia); Physics Department, Faculty of Science, South Valley University, Qena 83523 (Egypt); Zeyada, H.M. [Department of Physics, Faculty of Science at New Damietta, Damietta University, New Damietta 34517 (Egypt); El-Nahass, M.M. [Physics Department, Faculty of Education, Ain Shams University, Cairo (Egypt)

    2014-03-15

    X-rays diffraction and scanning electron microscope were used to investigate the structural properties of tetraphenylporphyrin, TPP, which is polycrystalline in a synthesized condition. It turns to amorphous structure upon thermal deposition. Annealing temperature ranging from 295 to 473 K does not influence the amorphous structure of films. The optical properties of TPP were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence in the wavelength range of 200–2200 nm. The absorption spectra were recorded in UV–visible region of spectra for the as-deposited and annealed samples show different absorption bands, namely four bands labeled as Q-band in visible region of spectra and a more intense band termed as the Soret band in near UV region of spectra. The Soret band shows its splitting (Davydov splitting). Two other bands labeled N and M appear in UV region. The film thickness has no influence on optical properties of films while annealing temperatures have a slight influence on optical properties of TPP films. The type of optical transition in as deposited and annealed conditions of films was found to be indirect allowed band-gap. Both fundamental and onset energy gap decreases upon annealing. -- Highlights: • Tetraphenylporphyrin (TPP) is polycrystalline in powder form, while the as-deposited and annealed TPP thin films have amorphous structure. • The absorption spectra of TPP in UV–visible region consists of Q-bands, Soret band and two other bands labeled N and M. • The optical parameters of TPP thin film were measured. • Thermal annealing influences optical properties of TPP thin films.

  17. The structural and optical characterizations of tetraphenylporphyrin thin films

    International Nuclear Information System (INIS)

    Makhlouf, M.M.; El-Denglawey, A.; Zeyada, H.M.; El-Nahass, M.M.

    2014-01-01

    X-rays diffraction and scanning electron microscope were used to investigate the structural properties of tetraphenylporphyrin, TPP, which is polycrystalline in a synthesized condition. It turns to amorphous structure upon thermal deposition. Annealing temperature ranging from 295 to 473 K does not influence the amorphous structure of films. The optical properties of TPP were investigated using spectrophotometric measurements of the transmittance and reflectance at normal incidence in the wavelength range of 200–2200 nm. The absorption spectra were recorded in UV–visible region of spectra for the as-deposited and annealed samples show different absorption bands, namely four bands labeled as Q-band in visible region of spectra and a more intense band termed as the Soret band in near UV region of spectra. The Soret band shows its splitting (Davydov splitting). Two other bands labeled N and M appear in UV region. The film thickness has no influence on optical properties of films while annealing temperatures have a slight influence on optical properties of TPP films. The type of optical transition in as deposited and annealed conditions of films was found to be indirect allowed band-gap. Both fundamental and onset energy gap decreases upon annealing. -- Highlights: • Tetraphenylporphyrin (TPP) is polycrystalline in powder form, while the as-deposited and annealed TPP thin films have amorphous structure. • The absorption spectra of TPP in UV–visible region consists of Q-bands, Soret band and two other bands labeled N and M. • The optical parameters of TPP thin film were measured. • Thermal annealing influences optical properties of TPP thin films

  18. Engineering Optics

    CERN Document Server

    Iizuka, Keigo

    2008-01-01

    Engineering Optics is a book for students who want to apply their knowledge of optics to engineering problems, as well as for engineering students who want to acquire the basic principles of optics. It covers such important topics as optical signal processing, holography, tomography, holographic radars, fiber optical communication, electro- and acousto-optic devices, and integrated optics (including optical bistability). As a basis for understanding these topics, the first few chapters give easy-to-follow explanations of diffraction theory, Fourier transforms, and geometrical optics. Practical examples, such as the video disk, the Fresnel zone plate, and many more, appear throughout the text, together with numerous solved exercises. There is an entirely new section in this updated edition on 3-D imaging.

  19. Optical forces through guided light deflections

    DEFF Research Database (Denmark)

    Palima, Darwin; Bañas, Andrew Rafael; Vizsnyiczai, Gaszton

    2013-01-01

    . In this work we look into the object shaping aspect and its potential for controlled optical manipulation. Using a simple bent waveguide as example, our numerical simulations show that the guided deflection of light efficiently converts incident light momentum into optical force with one order...

  20. Superhydrophobic surfaces: from fluid mechanics to optics

    NARCIS (Netherlands)

    Rathgen, H.

    2008-01-01

    In this thesis optical diraction was used to study the static and dynamic properties of microscopic liquid-gas interfaces that span between adjacent ridges of a superhydrophobic surface. An observed interference phenomenon at grazing incident angle led to the development of optical gratings with a

  1. Optical bistability controlling light with light

    CERN Document Server

    Gibbs, Hyatt

    1985-01-01

    Optical Bistability: Controlling Light with Light focuses on optical bistability in nonlinear optical systems. Emphasis is on passive (non-laser) systems that exhibit reversible bistability with input intensity as the hysteresis variable, along with the physics and the potential applications of such systems for nonlinear optical signal processing. This book consists of seven chapters and begins with a historical overview of optical bistability in lasers and passive systems. The next chapter describes steady-state theories of optical bistability, including the Bonifacio-Lugiato model, as we

  2. Extension of geometrical-optics approximation to on-axis Gaussian beam scattering. I. By a spherical particle.

    Science.gov (United States)

    Xu, Feng; Ren, Kuan Fang; Cai, Xiaoshu

    2006-07-10

    The geometrical-optics approximation of light scattering by a transparent or absorbing spherical particle is extended from plane wave to Gaussian beam incidence. The formulas for the calculation of the phase of each ray and the divergence factor are revised, and the interference of all the emerging rays is taken into account. The extended geometrical-optics approximation (EGOA) permits one to calculate the scattering diagram in all directions from 0 degrees to 180 degrees. The intensities of the scattered field calculated by the EGOA are compared with those calculated by the generalized Lorenz-Mie theory, and good agreement is found. The surface wave effect in Gaussian beam scattering is also qualitatively analyzed by introducing a flux ratio factor. The approach proposed is particularly important to the further extension of the geometrical-optics approximation to the scattering of large spheroidal particles.

  3. Solar cell angle of incidence corrections

    Science.gov (United States)

    Burger, Dale R.; Mueller, Robert L.

    1995-01-01

    Literature on solar array angle of incidence corrections was found to be sparse and contained no tabular data for support. This lack along with recent data on 27 GaAs/Ge 4 cm by 4 cm cells initiated the analysis presented in this paper. The literature cites seven possible contributors to angle of incidence effects: cosine, optical front surface, edge, shadowing, UV degradation, particulate soiling, and background color. Only the first three are covered in this paper due to lack of sufficient data. The cosine correction is commonly used but is not sufficient when the incident angle is large. Fresnel reflection calculations require knowledge of the index of refraction of the coverglass front surface. The absolute index of refraction for the coverglass front surface was not known nor was it measured due to lack of funds. However, a value for the index of refraction was obtained by examining how the prediction errors varied with different assumed indices and selecting the best fit to the set of measured values. Corrections using front surface Fresnel reflection along with the cosine correction give very good predictive results when compared to measured data, except there is a definite trend away from predicted values at the larger incident angles. This trend could be related to edge effects and is illustrated by a use of a box plot of the errors and by plotting the deviation of the mean against incidence angle. The trend is for larger deviations at larger incidence angles and there may be a fourth order effect involved in the trend. A chi-squared test was used to determine if the measurement errors were normally distributed. At 10 degrees the chi-squared test failed, probably due to the very small numbers involved or a bias from the measurement procedure. All other angles showed a good fit to the normal distribution with increasing goodness-of-fit as the angles increased which reinforces the very small numbers hypothesis. The contributed data only went to 65 degrees

  4. Investigation of a slot nanoantenna in optical frequency range

    Science.gov (United States)

    Dinesh kumar, V.; Asakawa, Kiyoshi

    2009-11-01

    Following the analogy of radio frequency slot antenna and its complementary dipole, we propose the implementation of a slot nanoantenna (SNA) in the optical frequency range. Using finite-difference time-domain (FDTD) method, we investigate the electromagnetic (EM) properties of a SNA formed in a thin gold film and compare the results with the properties of a gold dipole nanoantenna (DNA) of the same dimension as the slot. It is found that the response of the SNA is very similar to the DNA, like their counterparts in the radio frequency (RF) range. The SNA can enhance the near field intensity of incident field which strongly depends on its feedgap dimension. The resonance of the SNA is influenced by its slot length; for the increasing slot length, resonant frequency decreases whereas the sharpness of resonance increases. Besides, the resonance of the SNA is found sensitive to the thickness of metal film, when the latter is smaller than the skin depth. The effect of polarization of incident field on the EM response of the SNA was examined; the field enhancement is optimum when polarization is parallel to the feedgap. Finally, we calculate the radiation patterns of the DNA and SNA and compare them with those of the RF dipole antenna. The radiation pattern of the SNA is found to be independent of its slot length when excited at resonant frequency. To the best of our knowledge, this is the first study on a slot antenna in the optical frequency.

  5. Electron optics

    CERN Document Server

    Grivet, Pierre; Bertein, F; Castaing, R; Gauzit, M; Septier, Albert L

    1972-01-01

    Electron Optics, Second English Edition, Part I: Optics is a 10-chapter book that begins by elucidating the fundamental features and basic techniques of electron optics, as well as the distribution of potential and field in electrostatic lenses. This book then explains the field distribution in magnetic lenses; the optical properties of electrostatic and magnetic lenses; and the similarities and differences between glass optics and electron optics. Subsequent chapters focus on lens defects; some electrostatic lenses and triode guns; and magnetic lens models. The strong focusing lenses and pris

  6. Shape changing collisions of optical solitons, universal logic gates ...

    Indian Academy of Sciences (India)

    communication via optical fibers [1] and the observation of self trapping of optical beams ... From a theoretical point of view, in the context of intense optical pulse ...... play a pivotal role in the shape changing collision process. ...... [1] See for example, several articles in the Focus Issue on “Optical Solitons - Perspectives and.

  7. Analgesia, sedation, and memory of intensive care.

    Science.gov (United States)

    Capuzzo, M; Pinamonti, A; Cingolani, E; Grassi, L; Bianconi, M; Contu, P; Gritti, G; Alvisi, R

    2001-09-01

    The purpose of this article was to investigate the relationship between analgesia, sedation, and memory of intensive care. One hundred fifty-two adult, cooperative intensive care unit (ICU) patients were interviewed 6 months after hospital discharge about their memory of intensive care. The patient was considered to be cooperative when he/she was aware of self and environment at the interview. The patients were grouped as follows: A (45 patients) substantially no sedation, B (85) morphine, and C (22) morphine and other sedatives. The patients having no memory of intensive care were 38%, 34%, and 23% respectively, in the three groups. They were less ill, according to SAPS II (P memories was not different among the three groups. Females reported at least one emotional memory more frequently than males (odds ratio 4.17; 95% CI 10.97-1.59). The patients receiving sedatives in the ICU are not comparable with those receiving only opiates or nothing, due to the different clinical condition. The lack of memory of intensive care is present in one third of patients and is influenced more by length of stay in ICU than by the sedation received. Sedation does not influence the incidence of factual, sensation, and emotional memories of ICU admitted patients. Females have higher incidences of emotional memories than males. Copyright 2001 by W.B. Saunders Company

  8. Stochastic conditional intensity processes

    DEFF Research Database (Denmark)

    Bauwens, Luc; Hautsch, Nikolaus

    2006-01-01

    model allows for a wide range of (cross-)autocorrelation structures in multivariate point processes. The model is estimated by simulated maximum likelihood (SML) using the efficient importance sampling (EIS) technique. By modeling price intensities based on NYSE trading, we provide significant evidence......In this article, we introduce the so-called stochastic conditional intensity (SCI) model by extending Russell’s (1999) autoregressive conditional intensity (ACI) model by a latent common dynamic factor that jointly drives the individual intensity components. We show by simulations that the proposed...... for a joint latent factor and show that its inclusion allows for an improved and more parsimonious specification of the multivariate intensity process...

  9. Real time neutron reflectometry using neutron optical imaging

    International Nuclear Information System (INIS)

    Smith, Gregory S.; Majewski, Jaroslaw

    2001-01-01

    We will describe recent improvements to the SPEAR reflectometer at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos. One of the changes consists of wider convergent, incident-beam, collimation to take advantage of optical imaging for specular scattering. In addition, the instrument now views a partially coupled liquid hydrogen moderator as opposed to the decoupled moderator that was previous in-place. While the wavelength distribution is poorer, it matches the time (wavelength) resolution of the reflectometer more closely with the angular resolution. Since the integrated intensity of the partially coupled moderator is higher than the decoupled moderator, we show a similar gain in incident beam flux on the sample without loss of the ability to separate fringes. The increases in intensity from the moderator gain and the improved collimation combine to allow us to measure reflectivities with good statistics down to 10 -4 in a matter of minutes and reflectivities of 10 -6 in an hour. Examples of measurements showing the gain in data accumulation rates are presented. (author)

  10. Grazing incidence X-ray fluorescence analysis of buried interfaces in periodically structured crystalline silicon thin-film solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Eisenhauer, David; Preidel, Veit; Becker, Christiane [Young Investigator Group Nanostructured Silicon for Photovoltaic and Photonic Implementations (Nano-SIPPE), Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Berlin (Germany); Pollakowski, Beatrix; Beckhoff, Burkhard [Physikalisch-Technische Bundesanstalt, Berlin (Germany); Baumann, Jonas; Kanngiesser, Birgit [Institut fuer Optik und Atomare Physik, Technische Universitaet Berlin (Germany); Amkreutz, Daniel; Rech, Bernd [Institut Silizium Photovoltaik, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Berlin (Germany); Back, Franziska; Rudigier-Voigt, Eveline [SCHOTT AG, Mainz (Germany)

    2015-03-01

    We present grazing incidence X-ray fluorescence (GIXRF) experiments on 3D periodically textured interfaces of liquid phase crystallized silicon thin-film solar cells on glass. The influence of functional layers (SiO{sub x} or SiO{sub x}/SiC{sub x}) - placed between glass substrate and silicon during crystallization - on the final carbon and oxygen contaminations inside the silicon was analyzed. Baring of the buried structured silicon surface prior to GIXRF measurement was achieved by removal of the original nano-imprinted glass substrate by wet-chemical etching. A broad angle of incidence distribution was determined for the X-ray radiation impinging on this textured surface. Optical simulations were performed in order to estimate the incident radiation intensity on the structured surface profile considering total reflection and attenuation effects. The results indicate a much lower contamination level for SiO{sub x} compared to the SiO{sub x}/SiC{sub x} interlayers, and about 25% increased contamination when comparing structured with planar silicon layers, both correlating with the corresponding solar cell performances. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Circular Intensity Differential Scattering of chiral molecules

    Energy Technology Data Exchange (ETDEWEB)

    Bustamante, C.J.

    1980-12-01

    In this thesis a theory of the Circular Intensity Differential Scattering (CIDS) of chiral molecules as modelled by a helix oriented with respect to the direction of incidence of light is presented. It is shown that a necessary condition for the existence of CIDS is the presence of an asymmetric polarizability in the scatterer. The polarizability of the scatterer is assumed generally complex, so that both refractive and absorptive phenomena are taken into account.

  12. Childhood optic atrophy.

    Science.gov (United States)

    Mudgil, A V; Repka, M X

    2000-02-01

    To determine the causes, and relative incidence of the common causes, of optic nerve atrophy in children under 10 years old and to compare prevalent aetiologies with those given in previous studies. The Wilmer Information System database was searched to identify all children, diagnosed between 1987 and 1997 with optic atrophy, who were under 10 years old at diagnosis. The medical records of these children were reviewed retrospectively A total of 272 children were identified, Complications from premature birth were the most frequent aetiology of optic atrophy (n = 44, 16%); 68% of these premature infants having a history of intraventricular haemorrhage. Tumour was the second most common aetiology (n = 40, 15%). The most frequent tumour was pilocytic astrocytoma (50%), followed by craniopharyngioma (17%). Hydrocephalus, unrelated to tumour, was the third most common aetiology (n = 26, 10%). In 114 cases (42%), the cause of optic atrophy became manifest in the perinatal period and/or could be attributed to adverse events in utero. A cause was not determined in 4% of cases. In the last decade, prematurity and hydrocephalus appear to have become important causes of optic atrophy in childhood. This trend is probably the result of improved survival of infants with extremely low birth weight.

  13. Illusion induced overlapped optics.

    Science.gov (United States)

    Zang, XiaoFei; Shi, Cheng; Li, Zhou; Chen, Lin; Cai, Bin; Zhu, YiMing; Zhu, HaiBin

    2014-01-13

    The traditional transformation-based cloak seems like it can only hide objects by bending the incident electromagnetic waves around the hidden region. In this paper, we prove that invisible cloaks can be applied to realize the overlapped optics. No matter how many in-phase point sources are located in the hidden region, all of them can overlap each other (this can be considered as illusion effect), leading to the perfect optical interference effect. In addition, a singular parameter-independent cloak is also designed to obtain quasi-overlapped optics. Even more amazing of overlapped optics is that if N identical separated in-phase point sources covered with the illusion media, the total power outside the transformation region is N2I0 (not NI0) (I0 is the power of just one point source, and N is the number point sources), which seems violating the law of conservation of energy. A theoretical model based on interference effect is proposed to interpret the total power of these two kinds of overlapped optics effects. Our investigation may have wide applications in high power coherent laser beams, and multiple laser diodes, and so on.

  14. Studies of optical emission in the high intensity pumping regime of top-down ZnO nanostructures and thin films grown on c-sapphire substrates by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Divay, L.; Kostcheev, S.; McMurtry, S.; Lerondel, G. [Laboratoire de Nanotechnologie et d' Instrumentation Optique, ICD CNRS (FRE2848), Universite de Technologie de Troyes, Troyes (France); Rogers, D.J.; Teherani, F.H. [Nanovation SARL, Versailles, 91400 Orsay (France); Lusson, A. [GEMaC, CNRS - Universite de Versailles Saint-Quentin en Yvelines,Meudon (France)

    2008-07-01

    We report on the emission of Zinc Oxide (ZnO) thin films obtained by Pulsed Laser Deposition (PLD) under high intensity excitation. In order to clarify the origin of the emission bands, we compared results for high quality thin films (75 nm) before and after 'top-down' nanopatterning. A nanopattering technique was developed for this purpose. The technique combined Electron Beam Lithography (EBL) and lift-off techniques and Inductively Coupled Plasma Reactive Ion Etching (ICP RIE). The emission spectra of the two types of samples were found to have a difference in their fine structure that was attributed, in part, to the existence of guided emission in the thin films and exciton weak confinement effects in the nanostructures. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Applied optics

    International Nuclear Information System (INIS)

    Orszag, A.; Antonetti, A.

    1988-01-01

    The 1988 progress report, of the Applied Optics laboratory, of the (Polytechnic School, France), is presented. The optical fiber activities are focused on the development of an optical gyrometer, containing a resonance cavity. The following domains are included, in the research program: the infrared laser physics, the laser sources, the semiconductor physics, the multiple-photon ionization and the nonlinear optics. Investigations on the biomedical, the biological and biophysical domains are carried out. The published papers and the congress communications are listed [fr

  16. Cancer incidence among firefighters

    DEFF Research Database (Denmark)

    Pukkala, Eero; Martinsen, Jan Ivar; Weiderpass, Elisabete

    2014-01-01

    OBJECTIVES: Firefighters are potentially exposed to a wide range of known and suspected carcinogens through their work. The objectives of this study were to examine the patterns of cancer among Nordic firefighters, and to compare them with the results from previous studies. METHODS: Data for this......OBJECTIVES: Firefighters are potentially exposed to a wide range of known and suspected carcinogens through their work. The objectives of this study were to examine the patterns of cancer among Nordic firefighters, and to compare them with the results from previous studies. METHODS: Data...... for this study were drawn from a linkage between the census data for 15 million people from the five Nordic countries and their cancer registries for the period 1961-2005. SIR analyses were conducted with the cancer incidence rates for the entire national study populations used as reference rates. RESULTS......: A total of 16 422 male firefighters were included in the final cohort. A moderate excess risk was seen for all cancer sites combined, (SIR=1.06, 95% CI 1.02 to 1.11). There were statistically significant excesses in the age category of 30-49 years in prostate cancer (SIR=2.59, 95% CI 1.34 to 4...

  17. Precursor incident program at EDF

    International Nuclear Information System (INIS)

    Fourest, B.; Maliverney, B.; Rozenholc, M.; Piovesan, C.

    1998-01-01

    The precursor program was started by EDF in 1994, after an investigation of the US NRC's Accident Sequence Precursor Program. Since then, reported operational events identified as Safety Outstanding Events have been analyzed whenever possible using probabilistic methods based on PSAs. Analysis provides an estimate of the remaining protection against core damage at the time the incident occurred. Measuring the incidents' severity enables to detect incidents important regarding safety. Moreover, the most efficient feedback actions can be derived from the main accident sequences identified through the analysis. Therefore, incident probabilistic analysis provides a way to assess priorities in terms of treatment and resource allocation, and so, to implement countermeasures preventing further occurrence and development of the most significant incidents. As some incidents cannot be analyzed using this method, probabilistic analysis can only be one among the methods used to assess the nuclear power plants' safety level. Nevertheless, it provides an interesting complement to classical methods of deterministic studies. (author)

  18. Nested grazing incidence optics for x ray detection

    Science.gov (United States)

    Li, Lin-Sen; Qiang, Peng-Fei; Sheng, Li-Zhi; Liu, Yong-An; Liu, Zhe; Liu, Duo; Zhao, Bao-Sheng; Zhang, Chun-Min

    2017-09-01

    Not Available Project supported by the National Natural Science Foundation of China (Grant No. 61471357) and the State Key Laboratory of Geo-Information Engineering Foundation (Grant No. SKLGIE2014-M-2-1).

  19. Optimized systems for energy efficient optical tweezing

    Science.gov (United States)

    Kampmann, R.; Kleindienst, R.; Grewe, A.; Bürger, Elisabeth; Oeder, A.; Sinzinger, S.

    2013-03-01

    Compared to conventional optics like singlet lenses or even microscope objectives advanced optical designs help to develop properties specifically useful for efficient optical tweezers. We present an optical setup providing a customized intensity distribution optimized with respect to large trapping forces. The optical design concept combines a refractive double axicon with a reflective parabolic focusing mirror. The axicon arrangement creates an annular field distribution and thus clears space for additional integrated observation optics in the center of the system. Finally the beam is focused to the desired intensity distribution by a parabolic ring mirror. The compact realization of the system potentially opens new fields of applications for optical tweezers such as in production industries and micro-nano assembly.

  20. Patient Safety Incidents and Nursing Workload 1

    Science.gov (United States)

    Carlesi, Katya Cuadros; Padilha, Kátia Grillo; Toffoletto, Maria Cecília; Henriquez-Roldán, Carlos; Juan, Monica Andrea Canales

    2017-01-01

    ABSTRACT Objective: to identify the relationship between the workload of the nursing team and the occurrence of patient safety incidents linked to nursing care in a public hospital in Chile. Method: quantitative, analytical, cross-sectional research through review of medical records. The estimation of workload in Intensive Care Units (ICUs) was performed using the Therapeutic Interventions Scoring System (TISS-28) and for the other services, we used the nurse/patient and nursing assistant/patient ratios. Descriptive univariate and multivariate analysis were performed. For the multivariate analysis we used principal component analysis and Pearson correlation. Results: 879 post-discharge clinical records and the workload of 85 nurses and 157 nursing assistants were analyzed. The overall incident rate was 71.1%. It was found a high positive correlation between variables workload (r = 0.9611 to r = 0.9919) and rate of falls (r = 0.8770). The medication error rates, mechanical containment incidents and self-removal of invasive devices were not correlated with the workload. Conclusions: the workload was high in all units except the intermediate care unit. Only the rate of falls was associated with the workload. PMID:28403334

  1. Patient Safety Incidents and Nursing Workload

    Directory of Open Access Journals (Sweden)

    Katya Cuadros Carlesi

    Full Text Available ABSTRACT Objective: to identify the relationship between the workload of the nursing team and the occurrence of patient safety incidents linked to nursing care in a public hospital in Chile. Method: quantitative, analytical, cross-sectional research through review of medical records. The estimation of workload in Intensive Care Units (ICUs was performed using the Therapeutic Interventions Scoring System (TISS-28 and for the other services, we used the nurse/patient and nursing assistant/patient ratios. Descriptive univariate and multivariate analysis were performed. For the multivariate analysis we used principal component analysis and Pearson correlation. Results: 879 post-discharge clinical records and the workload of 85 nurses and 157 nursing assistants were analyzed. The overall incident rate was 71.1%. It was found a high positive correlation between variables workload (r = 0.9611 to r = 0.9919 and rate of falls (r = 0.8770. The medication error rates, mechanical containment incidents and self-removal of invasive devices were not correlated with the workload. Conclusions: the workload was high in all units except the intermediate care unit. Only the rate of falls was associated with the workload.

  2. Two 238Pu inhalation incidents

    International Nuclear Information System (INIS)

    Fleming, R.R.; Hall, R.M.

    1978-06-01

    Two employees inhaled significant amounts of 238 Pu in separate unrelated contamination incidents in 1977. Both acute exposure incidents are described and the urine, feces, and in-vivo chest count data for each employee. Case B ( 238 PuNO 3 ) received 24 DTPA treatments beginning the day of the incident while, for medical reasons, Case A ( 238 PuO 2 ) received no therapy

  3. Advanced optical system for scanning-spot photorefractive keratectomy (PRK)

    Science.gov (United States)

    Mrochen, Michael; Wullner, Christian; Semchishen, Vladimir A.; Seiler, Theo

    1999-06-01

    Purpose: The goal of this presentation is to discuss the use of the Light Shaping Beam Homogenizer in an optical system for scanning-spot PRK. Methods: The basic principle of the LSBH is the transformation of any incident intensity distribution by light scattering on an irregular microlens structure z = f(x,y). The relief of this microlens structure is determined by a defined statistical function, i.e. it is defined by the mean root-squared tilt σ of the surface relief. Therefore, the beam evolution after the LSBH and in the focal plane of an imaging lens was measured for various root-squared tilts. Beside this, an optical setup for scanning-spot PRK was assembled according to the theoretical and experimental results. Results: The divergence, homogeneity and the Gaussian radius of the intensity distribution in the treatment plane of the scanning-spot PRK laser system is mainly characterized by dependent on root-mean-square tilt σ of the LSBH, as it will be explained by the theoretical description of the LSBH. Conclusions: The LSBH represents a simple, low cost beam homogenizer with low energy losses, for scanning-spot excimer laser systems.

  4. Dysphonia in preterm children: assessing incidence and response to treatment.

    Science.gov (United States)

    Reynolds, Victoria; Meldrum, Suzanne; Simmer, Karen; Vijayasekaran, Shyan; French, Noel P

    2014-03-01

    Mild dysphonia in childhood is surprisingly common, yet moderate to severe dysphonia is rare. The latter has been associated with complex medical conditions and congenital abnormalities. Intubation injury has also been documented as a cause of childhood dysphonia. Children born very preterm may be intubated as part of the intensive care administered in the perinatal and neonatal periods, yet there are few studies investigating dysphonia in this population. This study will be the first to: use an objective acoustic voice assessment in a paediatric study, document the incidence of dysphonia in very preterm children at school age, and conduct a controlled trial of behavioural voice therapy in this population. This study will consist of three phases: assessment of voice quality and its impact on quality of life in up to 200 children born at less than 32 weeks' gestation: assessment of the nature and extent of laryngeal pathology in children with moderate to severe dysphonia; and a non-blinded, randomised controlled trial of behavioural voice therapy in children with moderate to severe dysphonia. This study will be the first to use clinical assessment to examine the voice quality of very preterm children, and to use fibre optic endoscopic evaluation of laryngeal function to determine the nature and extent of any laryngeal pathology in such children. Those participants with significant voice difficulties will be randomised to receive treatment immediately or after the eight week assessment. This study is registered on the Australian New Zealand Clinical Trials Registry (ACTRN12613001015730/ACTRN12613001012763). Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  5. Phase-Modulated Optical Communication Systems

    CERN Document Server

    Ho, Keang-Po

    2005-01-01

    Fiber-optic communication systems have revolutionized our telecommunication infrastructures – currently, almost all telephone land-line, cellular, and internet communications must travel via some form of optical fibers. In these transmission systems, neither the phase nor frequency of the optical signal carries information – only the intensity of the signal is used. To transmit more information in a single optical carrier, the phase of the optical carrier must be explored. As a result, there is renewed interest in phase-modulated optical communications, mainly in direct-detection DPSK signals for long-haul optical communication systems. When optical amplifiers are used to maintain certain signal level among the fiber link, the system is limited by amplifier noises and fiber nonlinearities. Phase-Modulated Optical Communication Systems surveys this newly popular area, covering the following topics: The transmitter and receiver for phase-modulated coherent lightwave systems Method for performance analysis o...

  6. Optics equations for aero-optical analysis

    Science.gov (United States)

    Sutton, George W.; Pond, John E.

    2011-05-01

    Aero-optical effects occur around moving air vehicles and impact passive imaging or active systems. The air flow around the vehicle is compressed, and often there is a turbulent shear and/or boundary layer both of which cause variations in the index of refraction. Examples of these are reconnaissance aircraft, the Stratospheric Observatory for Infrared Optics (SOFIA), and optically homing hypersonic interceptors. In other applications, a laser beam can be formed within the vehicle, and projected outward and focused on an object. These include the Airborne Laser Laboratory, Airborne Laser and the Airborne Tactical Laser. There are many compressible fluid mechanics computer programs that can predict the air density distribution of the surrounding flow field including density fluctuations in turbulent shear and/or boundary layers. It is necessary for the physical optics to be used to predict the properties of the ensuing image plane intensity distribution, whether passive or active. These include the time-averaged image blur circle and instantaneous realizations. (Ray tracing is a poor approximation that gives erroneous results for small aberrations.)

  7. Optical transitions in semiconductor nanospherical core/shell/shell heterostructure in the presence of radial electrostatic field

    Energy Technology Data Exchange (ETDEWEB)

    Baghdasaryan, D.A. [Russian-Armenian University, H. Emin 123, 0051 Yerevan (Armenia); Hayrapetyan, D.B., E-mail: dhayrap82@gmail.com [Russian-Armenian University, H. Emin 123, 0051 Yerevan (Armenia); Yerevan State University, A. Manoogian 1, 0025 Yerevan (Armenia); Harutyunyan, V.A. [Russian-Armenian University, H. Emin 123, 0051 Yerevan (Armenia)

    2017-04-01

    The electronic states and optical properties of spherical nanolayer in the presence of the electrostatic radial field in the strong size quantization regime have been considered. Both analytical and numerical methods have been applied to the problem of one-electron states in the system. According to the intensity of the external electrostatic field, three regimes have been distinguished: week, intermediate and strong. Perturbative approach have been applied to the case of week, WKB to the case of intermediate and variation approach to the case of strong field intensities. The analytical dependencies of the one electron energy and wave function on the electric field value and geometrical parameters of the nanolayer have been achieved. The comparison of the results obtained by the analytical method with the results of the numerical method have been made. The interband and intraband optical transitions caused by incident optical light polarized in z direction have been considered in this system. The selection rules for this transitions have been obtained. The dependence of the absorption coefficient on the energy of incident light for both cases of interband and intraband transitions for every regime of the electrostatic field value have been received. - Highlights: • The electron energy analytical dependencies on the electric field value have been achieved. • The selection rules for transitions between levels with different quantum numbers are revealed. • The interband and intraband absorption coefficients have been studied.

  8. Regeneration of Optic Nerve

    Directory of Open Access Journals (Sweden)

    Kwok-Fai So

    2011-05-01

    Full Text Available The optic nerve is part of the central nervous system (CNS and has a structure similar to other CNS tracts. The axons that form the optic nerve originate in the ganglion cell layer of the retina and extend through the optic tract. As a tissue, the optic nerve has the same organization as the white matter of the brain in regard to its glia. There are three types of glial cells: Oligodendrocytes, astrocytes, and microglia. Little structural and functional regeneration of the CNS takes place spontaneously following injury in adult mammals. In contrast, the ability of the mammalian peripheral nervous system (PNS to regenerate axons after injury is well documented. A number of factors are involved in the lack of CNS regeneration, including: (i the response of neuronal cell bodies against the damage; (ii myelin-mediated inhibition by oligodendrocytes; (iii glial scarring, by astrocytes; (iv macrophage infiltration; and (v insufficient trophic factor support. The fundamental difference in the regenerative capacity between CNS and PNS neuronal cell bodies has been the subject of intensive research. In the CNS the target normally conveys a retrograde trophic signal to the cell body. CNS neurons die because of trophic deprivation. Damage to the optic nerve disconnects the neuronal cell body from its target-derived trophic peptides, leading to the death of retinal ganglion cells. Furthermore, the axontomized neurons become less responsive to the peptide trophic signals they do receive. On the other hand, adult PNS neurons are intrinsically responsive to neurotrophic factors and do not lose trophic responsiveness after axotomy. In this talk different strategies to promote optic-nerve regeneration in adult mammals are reviewed. Much work is still needed to resolve many issues. This is a very important area of neuroregeneration and neuroprotection, as currently there is no cure after traumatic optic nerve injury or retinal disease such as glaucoma, which

  9. Fluidic optics

    Science.gov (United States)

    Whitesides, George M.; Tang, Sindy K. Y.

    2006-09-01

    Fluidic optics is a new class of optical system with real-time tunability and reconfigurability enabled by the introduction of fluidic components into the optical path. We describe the design, fabrication, operation of a number of fluidic optical systems, and focus on three devices, liquid-core/liquid-cladding (L2) waveguides, microfluidic dye lasers, and diffraction gratings based on flowing, crystalline lattices of bubbles, to demonstrate the integration of microfluidics and optics. We fabricate these devices in poly(dimethylsiloxane) (PDMS) with soft-lithographic techniques. They are simple to construct, and readily integrable with microanalytical or lab-on-a-chip systems.

  10. Optical fibres

    CERN Document Server

    Geisler, J; Boutruche, J P

    1986-01-01

    Optical Fibers covers numerous research works on the significant advances in optical fibers, with particular emphasis on their application.This text is composed of three parts encompassing 15 chapters. The first part deals with the manufacture of optical fibers and the materials used in their production. The second part describes optical-fiber connectors, terminals and branches. The third part is concerned with the major optoelectronic components encountered in optical-communication systems.This book will be of value to research scientists, engineers, and patent workers.

  11. Atom optics

    International Nuclear Information System (INIS)

    Balykin, V. I.; Jhe, W.

    1999-01-01

    Atom optics, in analogy to neutron and electron optics, deals with the realization of as a traditional elements, such as lenes, mirrors, beam splitters and atom interferometers, as well as a new 'dissipative' elements such as a slower and a cooler, which have no analogy in an another types of optics. Atom optics made the development of atom interferometer with high sensitivity for measurement of acceleration and rotational possible. The practical interest in atom optics lies in the opportunities to create atom microprobe with atom-size resolution and minimum damage of investigated objects. (Cho, G. S.)

  12. Optical interconnects

    CERN Document Server

    Chen, Ray T

    2006-01-01

    This book describes fully embedded board level optical interconnect in detail including the fabrication of the thin-film VCSEL array, its characterization, thermal management, the fabrication of optical interconnection layer, and the integration of devices on a flexible waveguide film. All the optical components are buried within electrical PCB layers in a fully embedded board level optical interconnect. Therefore, we can save foot prints on the top real estate of the PCB and relieve packaging difficulty reduced by separating fabrication processes. To realize fully embedded board level optical

  13. Nonlinear optics

    CERN Document Server

    Boyd, Robert W

    2013-01-01

    Nonlinear Optics is an advanced textbook for courses dealing with nonlinear optics, quantum electronics, laser physics, contemporary and quantum optics, and electrooptics. Its pedagogical emphasis is on fundamentals rather than particular, transitory applications. As a result, this textbook will have lasting appeal to a wide audience of electrical engineering, physics, and optics students, as well as those in related fields such as materials science and chemistry.Key Features* The origin of optical nonlinearities, including dependence on the polarization of light* A detailed treatment of the q

  14. Goiania incident case study

    International Nuclear Information System (INIS)

    Petterson, J.S.

    1988-06-01

    The reasons for wanting to document this case study and present the findings are simple. According to USDOE technical risk assessments (and our own initial work on the Hanford socioeconomic study), the likelihood of a major accident involving exposure to radioactive materials in the process of site characterization, construction, operation, and closure of a high-level waste repository is extremely remote. Most would agree, however, that there is a relatively high probability that a minor accident involving radiological contamination will occur sometime during the lifetime of the repository -- for example, during transport, at an MRS site or at the permanent site itself during repacking and deposition. Thus, one of the major concerns of the Yucca Mountain Socioeconomic Study is the potential impact of a relatively minor radiation-related accident. A large number of potential impact of a relatively minor radiation-related accident. A large number of potential accident scenarios have been under consideration (such as a transportation or other surface accident which results in a significant decline in tourism, the number of conventions, or the selection of Nevada as a retirement residence). The results of the work in Goiania make it clear, however, that such a significant shift in established social patterns and trends is not likely to occur as a direct outcome of a single nuclear-related accident (even, perhaps, a relatively major one), but rather, are likely to occur as a result of the enduring social interpretations of such an accident -- that is, as a result of the process of understanding, communicating, and socially sustaining a particular set of associations with respect to the initial incident

  15. What is refractive optical bistability

    International Nuclear Information System (INIS)

    Dzhehov, Tomislav

    1993-01-01

    The basic elements of the theory of refractive optical bistability, assuming mediums with linear absorption are given. Special attention is paid to bistable etalons of semiconductor materials an oxide glasses, since some of them are considered as promising components for optical bistability applications. The design optimization of such devices for minimum switching intensity is analyzed. Computer simulation of the transfer characteristic recording for two InSb etalons is presented. (author)

  16. Electro-optic polymeric reflection modulator based on plasmonic metamaterial

    Science.gov (United States)

    Abbas, A.; Swillam, M.

    2018-02-01

    A novel low power design for polymeric Electro-Optic reflection modulator is proposed based on the Extraordinary Reflection of light from multilayer structure consisting of a plasmonic metasurface with a periodic structure of sub wavelength circular apertures in a gold film above a thin layer of EO polymer and above another thin gold layer. The interference of the different reflected beams from different layer construct the modulated beam, The applied input driving voltage change the polymer refractive index which in turn determine whether the interference is constructive or destructive, so both phase and intensity modulation could be achieved. The resonant wavelength is tuned to the standard telecommunication wavelength 1.55μm, at this wavelength the reflection is minimum, while the absorption is maximum due to plasmonic resonance (PR) and the coupling between the incident light and the plasmonic metasurface.

  17. Optical Manipulation of a Magnon-Photon Hybrid System.

    Science.gov (United States)

    Braggio, C; Carugno, G; Guarise, M; Ortolan, A; Ruoso, G

    2017-03-10

    We demonstrate an all-optical method for manipulating the magnetization in a 1-mm yttrium-iron-garnet (YIG) sphere placed in a ∼0.17  T uniform magnetic field. A harmonic of the frequency comb delivered by a multi-GHz infrared laser source is tuned to the Larmor frequency of the YIG sphere to drive magnetization oscillations, which in turn give rise to a radiation field used to thoroughly investigate the phenomenon. The radiation damping issue that occurs at high frequency and in the presence of highly magnetizated materials has been overcome by exploiting the magnon-photon strong coupling regime in microwave cavities. Our findings demonstrate an effective technique for ultrafast control of the magnetization vector in optomagnetic materials via polarization rotation and intensity modulation of an incident laser beam. We eventually get a second-order susceptibility value of ∼10^{-7}  cm^{2}/MW for single crystal YIG.

  18. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ...

  19. AGS intensity upgrades

    International Nuclear Information System (INIS)

    Roser, T.

    1995-01-01

    After the successful completion of the AGS Booster and several upgrades of the AGS, a new intensity record of 6.3 x 10 13 protons per pulse accelerated to 24 GeV was achieved. The high intensity slow-extracted beam program at the AGS typically serves about five production targets and about eight experiments including three rare Kaon decay experiments. Further intensity upgrades are being discussed that could increase the average delivered beam intensity by up to a factor of four

  20. Conjugated Molecules for the Smart Filtering of Intense Radiations

    Directory of Open Access Journals (Sweden)

    Danilo Dini

    2003-04-01

    Full Text Available Abstract: The practical realization of smart optical filters, i.e. devices which change their optical transmission in a suitable way to keep a working state for a general light sensitive element , can involve the use of conjugated molecules whose light absorption properties are light- intensity dependent (nonlinear optical effect. The verification of optical limiting displayed by some particular conjugated molecules, e.g. phthalocyanines, is quite noteworthy and can be successfully exploited for the realization of such smart optical devices. In the present contribution the analysis of the relevant molecular feature of a phthalocyanine are analyzed with the aim of determining useful correlations between optical limiting performance and phthalocyanine chemical structure. In particular , the electronic nature of the substituent is considered as a key factor for the explanation of some observed optical limiting trends.

  1. A broadly tunable autocorrelator for ultra-short, ultra-high power infrared optical pulses

    Energy Technology Data Exchange (ETDEWEB)

    Szarmes, E.B.; Madey, J.M.J. [Duke Univ., Durham, NC (United States)

    1995-12-31

    We describe the design of a crossed-beam, optical autocorrelator that uses an uncoated, birefringent beamsplitter to split a linearly polarized incident pulse into two orthogonally polarized pulses, and a Type II, SHG crystal to generate the intensity autocorrelation function. The uncoated beamsplitter accommodates extremely broad tunability while precluding any temporal distortion of ultrashort optical pulses at the dielectric interface, and the specific design provides efficient operation between 1 {mu}m and 4 {mu}m. Furthermore, the use of Type II SHG completely eliminates any single-beam doubling, so the autocorrelator can be operated at very shallow crossed-beam angles without generating a background pedestal. The autocorrelator has been constructed and installed in the Mark III laboratory at Duke University as a broadband diagnostic for ongoing compression experiments on the chirped-pulse FEL.

  2. Optimization of plasma mirror reflectivity and optical quality using double laser pulses

    International Nuclear Information System (INIS)

    Scott, G G; Clarke, R J; Green, J S; Heathcote, R I; Neely, D; Bagnoud, V; Brabetz, C; Zielbauer, B; Powell, H W; McKenna, P; Arber, T D

    2015-01-01

    We measure a record 96 ±2.5% specularly reflected energy fraction from an interaction with a plasma mirror (PM) surface preionized by a controlled prepulse and find that the optical quality is dependent on the inter pulse time delay. Simulations show that the main pulse reflected energy is a strong function of plasma density scale length, which increases with the time delay and reaches a peak reflectivity for a scale length of 0.3 μm, which is achieved here for a pulse separation time of 3 ps. It is found that the incident laser quasi near field intensity distribution leads to nonuniformities in this plasma expansion and consequent critical surface position distribution. The PM optical quality is found to be governed by the resultant perturbations in the critical surface position, which become larger with inter pulse time delay. (paper)

  3. An automatic analyzer of solid state nuclear track detectors using an optic RAM as image sensor

    International Nuclear Information System (INIS)

    Staderini, E.M.; Castellano, A.

    1986-01-01

    An optic RAM is a conventional digital random access read/write dynamic memory device featuring a quartz windowed package and memory cells regularly ordered on the chip. Such a device is used as an image sensor because each cell retains data stored in it for a time depending on the intensity of the light incident on the cell itself. The authors have developed a system which uses an optic RAM to acquire and digitize images from electrochemically etched CR39 solid state nuclear track detectors (SSNTD) in the track count rate up to 5000 cm -2 . On the digital image so obtained, a microprocessor, with appropriate software, performs image analysis, filtering, tracks counting and evaluation. (orig.)

  4. Morphological and Optical Characterization of High Density Au/PAA Nanoarrays

    Directory of Open Access Journals (Sweden)

    Mohamed Shaban

    2016-01-01

    Full Text Available Hexagonal nanoarrays of Au nanorods and nanopillar were deposited on nanoporous anodic alumina (PAA membranes utilizing dc electrodeposition. The surface morphologies and optical properties were characterized by using field emission-scanning electron microscopy (FE-SEM and UV-Vis spectrophotometer, respectively. The optical reflectance spectra of the as-prepared, pore widened, and 2D-Au nanorods-coated PAA membranes were studied in detail. The effects of the angle of incident, pore widening time, and electrodeposition time on the characteristic peaks positions and intensities of the fabricated nanoarrays were addressed. As the angle of incident increased, the interference peaks and transverse surface resonance are shifted to longer wavelengths, but the longitudinal surface plasmon resonance is shifted to shorter wavelengths. Also, the reflected intensities are decreased linearly for the as-prepared sample and decreased exponentially for Au/PAA samples. Using the modified Kubelka-Munk radiative transfer model, the energy gap is increased from 2.83 to 3.06 eV and the refractive index is decreased from 1.84 to 1.36 for the as-prepared and 70 min pore widened PAA membranes, respectively. Based on the advantages of the fabrication approach and the enhanced and controlled properties, this generation of Au/PAA arrays can be used as efficient building blocks for nanoelectronics and nanophotonic devices.

  5. Progress in Ultrafast Intense Laser Science

    CERN Document Server

    Yamanouchi, Kaoru; Li, Ruxin; Chin, See Leang

    2009-01-01

    The PUILS series presents Progress in Ultrafast Intense Laser Science, a newly emerging interdisciplinary research field spanning atomic and molecular physics, molecular science, and optical science. PUILS has been stimulated by the recent development of ultrafast laser technologies. Each volume contains approximately 15 chapters, authored by researchers at the forefront. Each chapter opens with an overview of the topics to be discussed, so that researchers, who are not experts in the specific topics, as well as graduate students can grasp the importance and attractions of this sub-field of research, and these are followed by reports of cutting-edge discoveries. This fourth volume covers a broad range of topics from this interdisciplinary research field, focusing on strong field ionization of atoms; excitation, ionization and fragmentation of molecules; nonlinear intense optical phenomena and attosecond pulses; and laser - solid interactions and photoemission.

  6. Real time freeway incident detection.

    Science.gov (United States)

    2014-04-01

    The US Department of Transportation (US-DOT) estimates that over half of all congestion : events are caused by highway incidents rather than by rush-hour traffic in big cities. Real-time : incident detection on freeways is an important part of any mo...

  7. True incidence of vestibular schwannoma?

    DEFF Research Database (Denmark)

    Stangerup, Sven-Eric; Tos, Mirko; Thomsen, Jens

    2010-01-01

    The incidence of diagnosed sporadic unilateral vestibular schwannomas (VS) has increased, due primarily to more widespread access to magnetic resonance imaging.......The incidence of diagnosed sporadic unilateral vestibular schwannomas (VS) has increased, due primarily to more widespread access to magnetic resonance imaging....

  8. Optical observations geomagnetically conjugate to sprite-producing lightning discharges

    Directory of Open Access Journals (Sweden)

    R. A. Marshall

    2005-09-01

    Full Text Available Theoretical studies have predicted that large positive cloud-to-ground discharges can trigger a runaway avalanche process of relativistic electrons, forming a geomagnetically trapped electron beam. The beam may undergo pitch angle and energy scattering during its traverse of the Earth's magnetosphere, with a small percentage of electrons remaining in the loss cone and precipitating in the magnetically conjugate atmosphere. In particular, N2 1P and N2+1N optical emissions are expected to be observable. In July and August 2003, an attempt was made to detect these optical emissions, called "conjugate sprites", in correlation with sprite observations in Europe near . Sprite observations were made from the Observatoire du Pic du Midi (OMP in the French Pyrenées, and VLF receivers were installed in Europe to detect causative sferics and ionospheric disturbances associated with sprites. In the Southern Hemisphere conjugate region, the Wide-angle Array for Sprite Photometry (WASP was deployed at the South African Astronomical Observatory (SAAO, near Sutherland, South Africa, to observe optical emissions with a field-of-view magnetically conjugate to the Northern Hemisphere observing region. Observations at OMP revealed over 130 documented sprites, with WASP observations covering the conjugate region successfully for 30 of these events. However, no incidences of optical emissions in the conjugate hemisphere were found. Analysis of the conjugate optical data from SAAO, along with ELF energy measurements from Palmer Station, Antarctica, and charge-moment analysis, show that the lightning events during the course of this experiment likely had insufficient intensity to create a relativistic beam.

    Keywords. Ionosphere (Ionsophere-magnetosphere interactions; Ionospheric disturbances; Instruments and techniques

  9. Optical observations geomagnetically conjugate to sprite-producing lightning discharges

    Directory of Open Access Journals (Sweden)

    R. A. Marshall

    2005-09-01

    Full Text Available Theoretical studies have predicted that large positive cloud-to-ground discharges can trigger a runaway avalanche process of relativistic electrons, forming a geomagnetically trapped electron beam. The beam may undergo pitch angle and energy scattering during its traverse of the Earth's magnetosphere, with a small percentage of electrons remaining in the loss cone and precipitating in the magnetically conjugate atmosphere. In particular, N2 1P and N2+1N optical emissions are expected to be observable. In July and August 2003, an attempt was made to detect these optical emissions, called "conjugate sprites", in correlation with sprite observations in Europe near . Sprite observations were made from the Observatoire du Pic du Midi (OMP in the French Pyrenées, and VLF receivers were installed in Europe to detect causative sferics and ionospheric disturbances associated with sprites. In the Southern Hemisphere conjugate region, the Wide-angle Array for Sprite Photometry (WASP was deployed at the South African Astronomical Observatory (SAAO, near Sutherland, South Africa, to observe optical emissions with a field-of-view magnetically conjugate to the Northern Hemisphere observing region. Observations at OMP revealed over 130 documented sprites, with WASP observations covering the conjugate region successfully for 30 of these events. However, no incidences of optical emissions in the conjugate hemisphere were found. Analysis of the conjugate optical data from SAAO, along with ELF energy measurements from Palmer Station, Antarctica, and charge-moment analysis, show that the lightning events during the course of this experiment likely had insufficient intensity to create a relativistic beam. Keywords. Ionosphere (Ionsophere-magnetosphere interactions; Ionospheric disturbances; Instruments and techniques

  10. Applied optics and optical design

    CERN Document Server

    Conrady, Alexander Eugen

    1957-01-01

    ""For the optical engineer it is an indispensable work."" - Journal, Optical Society of America""As a practical guide this book has no rival."" - Transactions, Optical Society""A noteworthy contribution,"" - Nature (London)Part I covers all ordinary ray-tracing methods, together with the complete theory of primary aberrations and as much of higher aberration as is needed for the design of telescopes, low-power microscopes and simple optical systems. Chapters: Fundamental Equations, Spherical Aberration, Physical Aspect of Optical Images, Chromatic Aberration, Design of Achromatic Object-Glass

  11. Incidence of risk factors for hearing impairment in premature babies

    Directory of Open Access Journals (Sweden)

    Nikolić Mina

    2016-01-01

    Full Text Available According to the World Health Organization, the incidence of hearing impairment in newborn population is 1-3 per 1000 (WHO, 2012. Apart from that, many authors have found that the incidence of hearing impairment is twenty times higher, 2-4%, in neonatal intensive care unit (NICU. Thus, a congenital hearing loss is the most frequent sensory or motor deficit that could be diagnosed immediately upon birth. The objective of this study was to determine the incidence of risk factors for hearing impairment in the population of preterm babies. We were especially interested in the impact of gestational age at birth on the incidence of risk factors for hearing loss. A cohort of 150 preterm babies was enrolled in the study. They were hospitalized in the Institute for Neonatology in Belgrade during 2014 and 2015 and the data were obtained from their medical files. The results of this study indicate high incidence of risk factors for hearing impairment in this population of babies. Gestational age at birth had a strong, statistically significant, correlation with risk factor incidence in lower gestational age and vice versa. High incidence of risk factors and their interaction could account for twenty times higher occurrence of congenital and early acquired hearing loss in population of preterm babies compared to term neonates. These results imply the need for systematic audiological surveillance of prematurely born babies at least until 12 months of corrected age.

  12. Metabonomics and Intensive Care

    OpenAIRE

    Antcliffe, D; Gordon, AC

    2016-01-01

    This article is one of ten reviews selected from the Annual Update in Intensive Care and Emergency medicine 2016. Other selected articles can be found online at http://www.biomedcentral.com/collections/annualupdate2016. Further information about the Annual Update in Intensive Care and Emergency Medicine is available from http://www.springer.com/series/8901.

  13. Statistics of spatially integrated speckle intensity difference

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Yura, Harold

    2009-01-01

    We consider the statistics of the spatially integrated speckle intensity difference obtained from two separated finite collecting apertures. For fully developed speckle, closed-form analytic solutions for both the probability density function and the cumulative distribution function are derived...... here for both arbitrary values of the mean number of speckles contained within an aperture and the degree of coherence of the optical field. Additionally, closed-form expressions are obtained for the corresponding nth statistical moments....

  14. Mechanism of optical unidirectional transmission in subwavelength dual-metal gratings

    Science.gov (United States)

    Gao, H.; Zheng, Z. Y.; Hao, H. Y.; Dong, A. G.; Fan, Z. J.; Liu, D. H.

    2014-03-01

    The mechanism of optical unidirectional (OUD) transmission in parallel subwavelength dual-metal gratings was investigated. It was found that this kind of OUD phenomenon originates from the coupling of the surface plasmon polaritons (SPPs) between the front grating and a layer of metal film which replaces the rear grating. The higher the intensity of the coupled SPPs at the entrances of the rear grating, the higher the transmittance can be achieved. Basing on this property, an effective OUD example was achieved by exploring the intensity difference at the entrances of the rear gratings between the two incidences of opposite directions. In this kind of OUD, the positive transmittance can exceed 80 % and the difference between the transmittances of the two opposite directions can be as large as 63 %. The detailed design process was also presented.

  15. Transient photoconductivity and femtosecond nonlinear optical properties of a conjugated polymer-graphene oxide composite

    Energy Technology Data Exchange (ETDEWEB)

    Nalla, Venkatram; Ji Wei [Department of Physics, National University of Singapore, Singapore 117542 (Singapore); Polavarapu, Lakshminarayana; Manga, Kiran Kumar; Goh, Bee Min; Loh, Kian Ping; Xu Qinghua, E-mail: chmxqh@nus.edu.sg, E-mail: phyjiwei@nus.edu.sg [Department of Chemistry, National University of Singapore, Singapore 117543 (Singapore)

    2010-10-15

    A water soluble conjugated thiophene polymer, sodium salt of poly[2-(3-thienyl)ethoxy-4-butylsulfonate] (TPP), and graphene oxide (GO) composite film (GO-TPP) device was prepared. Transient photoconductivity measurements were carried out on the GO-TPP composite film using 150 ns laser pulses of 527 nm wavelength. Highly efficient photocurrent generation was observed from the GO-TPP film. The relationships of the film photoconductivity, photocurrent decay time and electron decay times with the incident light intensity were investigated. The photoconductive gain of the film was determined to be greater than 40% and to be independent of the light intensity. Furthermore, the femtosecond nonlinear optical properties of the GO-TPP film were measured using 800 nm femtosecond laser pulses and the composite film exhibited high nonlinear absorption and nonlinear refraction coefficients.

  16. Transient photoconductivity and femtosecond nonlinear optical properties of a conjugated polymer-graphene oxide composite

    International Nuclear Information System (INIS)

    Nalla, Venkatram; Ji Wei; Polavarapu, Lakshminarayana; Manga, Kiran Kumar; Goh, Bee Min; Loh, Kian Ping; Xu Qinghua

    2010-01-01

    A water soluble conjugated thiophene polymer, sodium salt of poly[2-(3-thienyl)ethoxy-4-butylsulfonate] (TPP), and graphene oxide (GO) composite film (GO-TPP) device was prepared. Transient photoconductivity measurements were carried out on the GO-TPP composite film using 150 ns laser pulses of 527 nm wavelength. Highly efficient photocurrent generation was observed from the GO-TPP film. The relationships of the film photoconductivity, photocurrent decay time and electron decay times with the incident light intensity were investigated. The photoconductive gain of the film was determined to be greater than 40% and to be independent of the light intensity. Furthermore, the femtosecond nonlinear optical properties of the GO-TPP film were measured using 800 nm femtosecond laser pulses and the composite film exhibited high nonlinear absorption and nonlinear refraction coefficients.

  17. The Incidence of Posttraumatic Stress Disorder After Floods: A Meta-Analysis.

    Science.gov (United States)

    Chen, Long; Liu, Aizhong

    2015-06-01

    This study analyzes the incidence of posttraumatic stress disorder (PTSD) among flood victims, between different flood intensities, and between different time points after a flood. A search of several electronic literature databases was conducted to collect data on the incidence of PTSD after a flood. Loney criteria for research quality were used to evaluate the quality of selected search results. The combined incidence of PTSD was estimated using the Freeman-Tukey double arcsine transformation method. Subgroup analyses were conducted on different trauma intensities and different time points after a flood. Sensitivity analysis was performed to evaluate the impact of research quality. Fourteen articles were included in this meta-analysis, including a total of 40 600 flood victims; 3862 victims were diagnosed with PTSD. The combined incidence of PTSD was 15.74%. The subgroup analyses showed that the incidence of PTSD in victims who experienced severe and moderate flood intensity was higher than that in victims who experienced mild flood intensity. The incidence of PTSD was lower at 6 or more months after a flood (11.45%) than within 6 months (16.01%) of a flood. In conclusion, the incidence of PTSD among floods of different trauma intensities was statistically significant.

  18. Stress ulcer prophylaxis in the intensive care unit

    DEFF Research Database (Denmark)

    Krag, Morten Brøgger; Perner, A; Wetterslev, J

    2013-01-01

    Stress ulcer prophylaxis (SUP) is regarded as standard of care in the intensive care unit (ICU). However, recent randomized, clinical trials (RCTs) and meta-analyses have questioned the rationale and level of evidence for this recommendation. The aim of the present systematic review was to evaluate...... incidence of gastrointestinal (GI) bleeding varies considerably. Data on the incidence and severity of GI bleeding in general ICUs in the developed world as of today are lacking. The best intervention for SUP is yet to be settled by balancing efficacy and harm. In essence, it is unresolved if intensive care...... patients benefit overall from SUP. The following clinically research questions are unanswered: (1) What is the incidence of GI bleeding, and which interventions are used for SUP in general ICUs today?; (2) Which criteria are used to prescribe SUP?; (3) What is the best SUP intervention?; (4) Do intensive...

  19. Microstructured Optical Fibres

    DEFF Research Database (Denmark)

    1999-01-01

    The present invention relates to a new class of optical waveguides, in which waveguiding along one or more core regions is obtained through the application of the Photonic Bandgap (PBG) effect. The invention further relates to optimised two-dimensional lattice structures capable of providing......, which are easy to manufacture. Finally, the present invention relates to a new fabrication technique, which allows easy manufacturing of preforms for photonic crystal fibers with large void filling fractions, as well as it allows a high flexibility in the design of the cladding and core structures....... complete PBGs, which reflects light incident from air or vacuum. Such structures may be used as cladding structures in optical fibres, where light is confined and thereby guided in a hollow core region. In addition, the present invention relates to designs for ultra low-loss PBG waveguiding structures...

  20. Catenary optics for achromatic generation of perfect optical angular momentum

    Science.gov (United States)

    Pu, Mingbo; Li, Xiong; Ma, Xiaoliang; Wang, Yanqin; Zhao, Zeyu; Wang, Changtao; Hu, Chenggang; Gao, Ping; Huang, Cheng; Ren, Haoran; Li, Xiangping; Qin, Fei; Yang, Jing; Gu, Min; Hong, Minghui; Luo, Xiangang

    2015-01-01

    The catenary is the curve that a free-hanging chain assumes under its own weight, and thought to be a “true mathematical and mechanical form” in architecture by Robert Hooke in the 1670s, with nevertheless no significant phenomena observed in optics. We show that the optical catenary can serve as a unique building block of metasurfaces to produce continuous and linear phase shift covering [0, 2π], a mission that is extremely difficult if not impossible for state-of-the-art technology. Via catenary arrays, planar optical devices are designed and experimentally characterized to generate various kinds of beams carrying orbital angular momentum (OAM). These devices can operate in an ultra-broadband spectrum because the anisotropic modes associated with the spin-orbit interaction are almost independent of the incident light frequency. By combining the optical and topological characteristics, our approach would allow the complete control of photons within a single nanometric layer. PMID:26601283