WorldWideScience

Sample records for incident optical intensity

  1. Grazing Incidence Optics Technology

    Science.gov (United States)

    Ramsey, Brian; Smith, W. Scott; Gubarev, Mikhail; McCracken, Jeff

    2015-01-01

    This project is to demonstrate the capability to directly fabricate lightweight, high-resolution, grazing-incidence x-ray optics using a commercially available robotic polishing machine. Typical x-ray optics production at NASA Marshall Space Flight Center (MSFC) uses a replication process in which metal mirrors are electroformed on to figured and polished mandrels from which they are later removed. The attraction of this process is that multiple copies can be made from a single master. The drawback is that the replication process limits the angular resolution that can be attained. By directly fabricating each shell, errors inherent in the replication process are removed. The principal challenge now becomes how to support the mirror shell during all aspects of fabrication, including the necessary metrology to converge on the required mirror performance specifications. This program makes use of a Zeeko seven-axis computer-controlled polishing machine (see fig. 1) and supporting fabrication, metrology, and test equipment at MSFC. The overall development plan calls for proof-of-concept demonstration with relatively thick mirror shells (5-6 mm, fig. 2) which are straightforward to support and then a transition to much thinner shells (2-3 mm), which are an order of magnitude thinner than those used for Chandra. Both glass and metal substrates are being investigated. Currently, a thick glass shell is being figured. This has enabled experience to be gained with programming and operating the polishing machine without worrying about shell distortions or breakage. It has also allowed time for more complex support mechanisms for figuring/ polishing and metrology to be designed for the more challenging thinner shells. These are now in fabrication. Figure 1: Zeeko polishing machine.

  2. Grazing Incidence Neutron Optics

    Science.gov (United States)

    Gubarev, Mikhail V. (Inventor); Ramsey, Brian D. (Inventor); Engelhaupt, Darell E. (Inventor)

    2013-01-01

    Neutron optics based on the two-reflection geometries are capable of controlling beams of long wavelength neutrons with low angular divergence. The preferred mirror fabrication technique is a replication process with electroform nickel replication process being preferable. In the preliminary demonstration test an electroform nickel optics gave the neutron current density gain at the focal spot of the mirror at least 8 for neutron wavelengths in the range from 6 to 20.ANG.. The replication techniques can be also be used to fabricate neutron beam controlling guides.

  3. Sensemaking in Military Critical Incidents: The Impact of Moral Intensity

    NARCIS (Netherlands)

    de Graaff, Miriam; Giebels, Ellen; Meijer, Dominique J.W.; Verweij, Desiree E.M.

    2016-01-01

    This study explores the relationship between moral intensity and the use of different sensemaking strategies in military critical incidents. First, narratives of military personnel were used to select prototypical high/low moral intensity critical incidents. In a follow-up, a scenario study was

  4. The current status of grazing incidence optics

    International Nuclear Information System (INIS)

    Aschenbach, B.

    1983-01-01

    The developments in the area of grazing incidence optics with emphasis on telescopes for use in X-ray astronomy are reviewed. The performance of existing high-resolution telescopes is outlined and compared with those expected from future missions like ROSAT and AXAF. Starting from the basic principles of X-ray reflection and scattering, an attempt is made to highlight the current understanding of X-ray mirror physics using new theoretical ideas as well as experimental laboratory results. (author)

  5. Pediatric safety incidents from an intensive care reporting system.

    Science.gov (United States)

    Skapik, Julia Lynn; Pronovost, Peter J; Miller, Marlene R; Thompson, David A; Wu, Albert W

    2009-06-01

    Adverse events impose a great burden on patients and the health care system, but not enough is known about how to address incidents involving pediatric patients. This study examined the demographic factors, types of events, contributing system factors, and harm associated with incidents that occur in pediatric intensive care units. Cross-sectional analysis of 2 years of data on all pediatric safety incidents and near misses reported to the voluntary provider-recorded Intensive Care Unit Safety Reporting System in regards to harm and contributing factors. In 464 incidents reported from 23 intensive care units to the Intensive Care Unit Safety Reporting System, patients were physically injured in one third of incidents and harmed in some way in two thirds of incidents. Medication errors were the most common incident type, but were associated with less harm than other event types. Line, tube, and airway events comprised one third of incidents and were associated with more harm than other types. Patient contributing factors were a strong predictor of harm; training and education factors were also commonly cited. In multivariate analysis, patient factors were the strongest predictor of harm adjusting for age, sex, and race. Pediatric patients are commonly harmed in intensive care units. There are several potential ways to improve safety including protocols for high-risk procedures involving lines and tubes, improved monitoring, and staffing, training and communication initiatives. Providers may be able to identify patients at increased risk for harm and intervene to protect patient safety.

  6. Specialty-based, voluntary incident reporting in neonatal intensive care: description of 4846 incident reports

    NARCIS (Netherlands)

    Snijders, C.; van Lingen, R. A.; Klip, H.; Fetter, W. P. F.; van der Schaaf, T. W.; Molendijk, H. A.; Kok, J. H.; te Pas, E.; Pas, H.; van der Starre, C.; Bloemendaal, E.; Lopes Cardozo, R. H.; Molenaar, A. M.; Giezen, A.; Maat, H. E.; Molendijk, A.; Lavrijssen, S.; Mulder, A. L. M.; de Kleine, M. J. K.; Koolen, A. M. P.; Schellekens, M.; Verlaan, W.; Vrancken, S.; Schotman, L.; van der Zwaan, A.; van der Tuijn, Y.; Tibboel, D.; Kollen, B. J.

    2009-01-01

    OBJECTIVES: To examine the characteristics of incidents reported after introduction of a voluntary, non-punitive incident reporting system for neonatal intensive care units (NICUs) in the Netherlands; and to investigate which types of reported incident pose the highest risk to patients in the NICU.

  7. The Incidence and Intensity of Formal Lifelong Learning

    DEFF Research Database (Denmark)

    Simonsen, Marianne; Skipper, Lars

    We exploit a rich high quality register-based employer-employee panel data set to investigate the incidence and intensity of government co-sponsored training for the Danish adult population. We focus specifically on training over the working life cycle and find that the levels of participation va...

  8. Intensity-dependent nonlinear optical properties in a modulation-doped single quantum well

    International Nuclear Information System (INIS)

    Ungan, F.

    2011-01-01

    In the present work, the changes in the intersubband optical absorption coefficients and the refractive index in a modulation-doped quantum well have been investigated theoretically. Within the envelope function approach and the effective mass approximation, the electronic structure of the quantum well is calculated from the self-consistent numerical solution of the coupled Schroedinger-Poisson equations. The analytical expressions of optical properties are obtained by using the compact density-matrix approach. The numerical results GaAs/Al x Ga 1-x As are presented for typical modulation-doped quantum well system. The linear, third-order nonlinear and total absorption and refractive index changes depending on the doping concentration are investigated as a function of the incident optical intensity and structure parameters, such as quantum well width and stoichiometric ratio. The results show that the doping concentration, the structure parameters and the incident optical intensity have a great effect on the optical characteristics of these structures. - Highlights: → The doping concentration has a great effect on the optical characteristics of these structures. → The structure parameters have a great effect on the optical properties of these structures. → The total absorption coefficients reduced as the incident optical intensity increases. → The RICs reduced as the incident optical intensity increases.

  9. Optical mapping at increased illumination intensities

    Science.gov (United States)

    Kanaporis, Giedrius; Martišienė, Irma; Jurevičius, Jonas; Vosyliūtė, Rūta; Navalinskas, Antanas; Treinys, Rimantas; Matiukas, Arvydas; Pertsov, Arkady M.

    2012-09-01

    Voltage-sensitive fluorescent dyes have become a major tool in cardiac and neuro-electrophysiology. Achieving high signal-to-noise ratios requires increased illumination intensities, which may cause photobleaching and phototoxicity. The optimal range of illumination intensities varies for different dyes and must be evaluated individually. We evaluate two dyes: di-4-ANBDQBS (excitation 660 nm) and di-4-ANEPPS (excitation 532 nm) in the guinea pig heart. The light intensity varies from 0.1 to 5 mW/mm2, with the upper limit at 5 to 10 times above values reported in the literature. The duration of illumination was 60 s, which in guinea pigs corresponds to 300 beats at a normal heart rate. Within the identified duration and intensity range, neither dye shows significant photobleaching or detectable phototoxic effects. However, light absorption at higher intensities causes noticeable tissue heating, which affects the electrophysiological parameters. The most pronounced effect is a shortening of the action potential duration, which, in the case of 532-nm excitation, can reach ˜30%. At 660-nm excitation, the effect is ˜10%. These findings may have important implications for the design of optical mapping protocols in biomedical applications.

  10. Critical incidents connected to nurses’ leadership in Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Elaine Cantarella Lima

    Full Text Available ABSTRACT Objective: The goal of this study is to analyze nurses’ leadership in intensive care units at hospitals in the state of São Paulo, Brazil, in the face of positive and negative critical incidents. Method: Exploratory, descriptive study, conducted with 24 nurses by using the Critical Incident Technique as a methodological benchmark. Results: Results were grouped into 61 critical incidents distributed into categories. Researchers came to the conclusion that leadership-related situations interfere with IC nurses’ behaviors. Among these situations they found: difficulty in the communication process; conflicts in the daily exercise of nurses’ activities; people management; and the setting of high quality care targets. Final considerations: Researchers identified a mixed leadership model, leading them to the conclusion that nurses’ knowledge and practice of contemporary leadership theories/styles are crucial because they facilitate the communication process, focusing on behavioral aspects and beliefs, in addition to valuing flexibility. This positively impacts the organization’s results.

  11. Active Full-Shell Grazing-Incidence Optics

    Science.gov (United States)

    Davis, Jacqueline M.; Elsner, Ronald F.; Ramsey, Brian D.; O'Dell, Stephen L.; Kolodziejczak, Jeffery; Weisskopf, Martin C.; Gubarev, Mikhail V.

    2016-01-01

    MSFC has a long history of developing full-shell grazing-incidence x-ray optics for both narrow (pointed) and wide field (surveying) applications. The concept presented in this paper shows the potential to use active optics to switch between narrow and wide-field geometries, while maintaining large effective area and high angular resolution. In addition, active optics has the potential to reduce errors due to mounting and manufacturing lightweight optics. The design presented corrects low spatial frequency error and has significantly fewer actuators than other concepts presented thus far in the field of active x-ray optics. Using a finite element model, influence functions are calculated using active components on a full-shell grazing-incidence optic. Next, the ability of the active optic to effect a change of optical prescription and to correct for errors due to manufacturing and mounting is modeled.

  12. Optical Co-Incidence Gate | Srinivasulu | African Journal of Science ...

    African Journals Online (AJOL)

    The paper explains Optical co-incidence gate, realized using Unijunction transistors (UJT), Light emitting diodes (LED) and Photo-resistors (LDR), which works on 1.8Vdc instead of 3Vdc. The power dissipation of the designed gate is only 3 mW. This optical gate finds application in the field of Mechatronics, Instrumentation ...

  13. Mutual optical intensity propagation through non-ideal mirrors.

    Science.gov (United States)

    Meng, Xiangyu; Shi, Xianbo; Wang, Yong; Reininger, Ruben; Assoufid, Lahsen; Tai, Renzhong

    2017-09-01

    The mutual optical intensity (MOI) model is extended to include the propagation of partially coherent radiation through non-ideal mirrors. The propagation of the MOI from the incident to the exit plane of the mirror is realised by local ray tracing. The effects of figure errors can be expressed as phase shifts obtained by either the phase projection approach or the direct path length method. Using the MOI model, the effects of figure errors are studied for diffraction-limited cases using elliptical cylinder mirrors. Figure errors with low spatial frequencies can vary the intensity distribution, redistribute the local coherence function and distort the wavefront, but have no effect on the global degree of coherence. The MOI model is benchmarked against HYBRID and the multi-electron Synchrotron Radiation Workshop (SRW) code. The results show that the MOI model gives accurate results under different coherence conditions of the beam. Other than intensity profiles, the MOI model can also provide the wavefront and the local coherence function at any location along the beamline. The capability of tuning the trade-off between accuracy and efficiency makes the MOI model an ideal tool for beamline design and optimization.

  14. Critical incidents connected to nurses' leadership in Intensive Care Units.

    Science.gov (United States)

    Lima, Elaine Cantarella; Bernardes, Andrea; Baldo, Priscila Lapaz; Maziero, Vanessa Gomes; Camelo, Silvia Helena Henriques; Balsanelli, Alexandre Pazetto

    2017-01-01

    The goal of this study is to analyze nurses' leadership in intensive care units at hospitals in the state of São Paulo, Brazil, in the face of positive and negative critical incidents. Exploratory, descriptive study, conducted with 24 nurses by using the Critical Incident Technique as a methodological benchmark. Results were grouped into 61 critical incidents distributed into categories. Researchers came to the conclusion that leadership-related situations interfere with IC nurses' behaviors. Among these situations they found: difficulty in the communication process; conflicts in the daily exercise of nurses' activities; people management; and the setting of high quality care targets. Researchers identified a mixed leadership model, leading them to the conclusion that nurses' knowledge and practice of contemporary leadership theories/styles are crucial because they facilitate the communication process, focusing on behavioral aspects and beliefs, in addition to valuing flexibility. This positively impacts the organization's results. Analisar a liderança do enfermeiro em Centros de Terapia Intensiva de hospitais localizados no interior do estado de São Paulo, diante de incidentes críticos positivos e negativos. Estudo exploratório, descritivo, realizado com 24 enfermeiros, que utilizou a Técnica do Incidente Crítico como referencial metodológico. Os resultados foram agrupados em 61 incidentes críticos distribuídos em categorias. Identificou-se que situações relacionadas à liderança interferem no comportamento do enfermeiro de Terapia Intensiva, dentre elas: dificuldade no processo de comunicação, conflitos existentes no dia a dia do exercício profissional, gerenciamento de pessoas e estabelecimento de metas para o alcance da assistência qualificada. Encontrou-se um modelo misto de liderança, o que permite concluir que o conhecimento e a prática dos enfermeiros acerca de teorias/estilos contemporâneos de liderança tornam-se fundamentais, pois

  15. Adjustable Grazing-Incidence X-Ray Optics

    Science.gov (United States)

    O'Dell, Stephen L.; Reid, Paul B.

    2015-01-01

    With its unique subarcsecond imaging performance, NASA's Chandra X-ray Observatory illustrates the importance of fine angular resolution for x-ray astronomy. Indeed, the future of x-ray astronomy relies upon x-ray telescopes with comparable angular resolution but larger aperture areas. Combined with the special requirements of nested grazing-incidence optics, mass, and envelope constraints of space-borne telescopes render such advances technologically and programmatically challenging. The goal of this technology research is to enable the cost-effective fabrication of large-area, lightweight grazing-incidence x-ray optics with subarcsecond resolution. Toward this end, the project is developing active x-ray optics using slumped-glass mirrors with thin-film piezoelectric arrays for correction of intrinsic or mount-induced distortions.

  16. Spiral intensity patterns in the internally pumped optical parametric oscillator

    DEFF Research Database (Denmark)

    Lodahl, Peter; Bache, Morten; Saffman, Mark

    2001-01-01

    We describe a nonlinear optical system that supports spiral pattern solutions in the field intensity. This new spatial structure is found to bifurcate above a secondary instability in the internally pumped optical parametric oscillator. The analytical predictions of threshold and spatial scale...

  17. Transverse beam shape measurements of intense proton beams using optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Scarpine, Victor E.; /Fermilab

    2012-03-01

    A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.

  18. Experimental Investigation of Integrated Optical Intensive Impulse Electric Field Sensors

    International Nuclear Information System (INIS)

    Bao, Sun; Fu-Shen, Chen

    2009-01-01

    We design and fabricate an integrated optical electric field sensor with segmented electrode for intensive impulse electric field measurement. The integrated optical sensor is based on a Mach–Zehnder interferometer with segmented electrodes. The output/input character of the sensing system is analysed and measured. The maximal detectable electric field range (−75 kV/m to 245 kV/m) is obtained by analysing the results. As a result, the integrated optics electric field sensing system is suitable for transient intensive electric field measurement investigation

  19. Controlling normal incident optical waves with an integrated resonator.

    Science.gov (United States)

    Qiu, Ciyuan; Xu, Qianfan

    2011-12-19

    We show a diffraction-based coupling scheme that allows a micro-resonator to directly manipulate a free-space optical beam at normal incidence. We demonstrate a high-Q micro-gear resonator with a 1.57-um radius whose vertical transmission and reflection change 40% over a wavelength range of only 0.3 nm. Without the need to be attached to a waveguide, a dense 2D array of such resonators can be integrated on a chip for spatial light modulation and parallel bio-sensing.

  20. Incidence, progression and intensity of Bud Rot in Elaeis guineensis Jacq. in San Lorenzo, Ecuador

    Directory of Open Access Journals (Sweden)

    Fernando Rivas Figueroa

    2017-01-01

    Full Text Available BUD rot (BR is the most serious disease of oil palm in Latin America; in Equator has caused more than 150 million USD of losses. The aim of this work was to determine the incidence, progression and disease intensity of BR in E. guineensis. Incidence and disease progression was determined from data of oil palm enterprises: Palesema, PDA, Palpailón, Energy & Palma y Alespalma during 2006-2013. Disease intensity was determined at 2013. Incidence was 66.75 % and disease intensity was 46 %. Based on projections of accumulative incidence a polynomial equation was built that predicted 78.30 % of cumulative incidence for 2014, indicating exponential growth of BR from 2009 to 2013. Magnitude of damages based on incidence, disease progression and infection index indicated the occurrence of a lethal form of BR in San Lorenzo, province of Esmeraldas, Equator.

  1. Development of Grazing Incidence Optics for Neutron Imaging and Scattering

    Science.gov (United States)

    Gubarev, M. V.; Khaykovich, B.; Liu, D.; Ramsey, B. D.; Zavlin, V. E.; Kilaru, K.; Romaine, S.; Rosati, R. E.; Bruni, R.; Moncton, D. E.

    2012-01-01

    Because of their wave nature, thermal and cold neutrons can be reflected from smooth surfaces at grazing incidence angles, be reflected by multilayer coatings or be refracted at boundaries of different materials. The optical properties of materials are characterized by their refractive indices which are slightly less than unity for most elements and their isotopes in the case of cold and thermal neutrons as well as for x-rays. The motivation for the optics use for neutrons as well as for x-rays is to increase the signal rate and, by virtue of the optic's angular resolution, to improve the signal-to-noise level by reducing the background so the efficiency of the existing neutron sources use can be significantly enhanced. Both refractive and reflective optical techniques developed for x-ray applications can be applied to focus neutron beams. Typically neutron sources have lower brilliance compared to conventional x-ray sources so in order to increase the beam throughput the neutron optics has to be capable of capturing large solid angles. Because of this, the replicated optics techniques developed for x-ray astronomy applications would be a perfect match for neutron applications, so the electroformed nickel optics under development at the Marshall Space Flight Center (MSFC) can be applied to focus neutron beams. In this technique, nickel mirror shells are electroformed onto a figured and superpolished nickel-plated aluminum cylindrical mandrel from which they are later released by differential thermal contraction. Cylindrical mirrors with different diameters, but the same focal length, can be nested together to increase the system throughput. The throughput can be increased further with the use of the multilayer coatings deposited on the reflectivr surface of the mirror shells. While the electroformed nickel replication technique needs to be adopted for neutron focusing, the technology to coat the inside of cylindrical mirrors with neutron multilayers has to be

  2. Incidence of intravenous drug incompatibilities in intensive care units

    Czech Academy of Sciences Publication Activity Database

    Machotka, O.; Maňák, J.; Kuběna, Aleš Antonín; Vlček, J.

    2015-01-01

    Roč. 159, č. 4 (2015), s. 652-656 ISSN 1213-8118 Institutional support: RVO:67985556 Keywords : medical error * graph theory * graph coloring * drug administration * drug incompatibilities * applied combinatorics * decision theory * medical * medication safety * intensive care units Subject RIV: FN - Epidemiology, Contagious Diseases ; Clinical Immunology Impact factor: 0.924, year: 2015 http://library.utia.cas.cz/separaty/2014/E/kubena-0437509.pdf

  3. Exercise Intensity and Incidence of Metabolic Syndrome: The SUN Project.

    Science.gov (United States)

    Hidalgo-Santamaria, María; Fernandez-Montero, Alejandro; Martinez-Gonzalez, Miguel A; Moreno-Galarraga, Laura; Sanchez-Villegas, Almudena; Barrio-Lopez, María T; Bes-Rastrollo, Maira

    2017-04-01

    Emerging evidence suggests that vigorous physical activity may be associated with higher cardioprotective benefits than moderate physical activity. This study aimed to assess the long-term relationship between the intensity of leisure time physical activity (LTPA) and the risk of developing metabolic syndrome (MS) in a prospective cohort study. The Seguimiento Universidad de Navarra (SUN) Project comprises Spanish university graduates. Participants (n=10,145) initially free of MS were followed for a minimum of 6 years (2008-2014). Analysis was conducted in 2015. Physical activity was assessed though a validated questionnaire. The intensity of each physical activity was measured in METs. The intensity of LTPA was estimated by the ratio between total METs/week and total hours of LTPA/week, obtaining the mean METs/hour of LTPA. MS was defined according to the harmonizing definition. The association between the intensity of LTPA (METs/hour) and MS was assessed with logistic regression models adjusting for potential confounders. Among 10,145 participants initially free of any MS criteria, 412 new MS cases were observed. Vigorous LTPA was associated with a 37% relatively lower risk (AOR=0.63, 95% CI=0.44, 0.89) compared with light LTPA. For a given total energy expenditure, independent of the time spent on it, participants who performed vigorous LTPA exhibited a higher reduction in the risk of MS than those who performed light to moderate LTPA. Vigorous LTPA was significantly associated with lower risk of developing MS after a 6-year follow-up period. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  4. Low-SNR Capacity of MIMO Optical Intensity Channels

    KAUST Repository

    Chaaban, Anas

    2017-09-18

    The capacity of the multiple-input multiple-output (MIMO) optical intensity channel is studied, under both average and peak intensity constraints. We focus on low SNR, which can be modeled as the scenario where both constraints proportionally vanish, or where the peak constraint is held constant while the average constraint vanishes. A capacity upper bound is derived, and is shown to be tight at low SNR under both scenarios. The capacity achieving input distribution at low SNR is shown to be a maximally-correlated vector-binary input distribution. Consequently, the low-SNR capacity of the channel is characterized. As a byproduct, it is shown that for a channel with peak intensity constraints only, or with peak intensity constraints and individual (per aperture) average intensity constraints, a simple scheme composed of coded on-off keying, spatial repetition, and maximum-ratio combining is optimal at low SNR.

  5. Brief Report: Incidence of and Risk Factors for Autistic Disorder in Neonatal Intensive Care Unit Survivors.

    Science.gov (United States)

    Matsuishi, Toyojiro; Yamashita, Yushiro; Ohtani, Yasuyo; Ornitz, Edward; Kuriya, Norikazu; Murakami, Yoshihiko; Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Fumio

    1999-01-01

    Analysis of the incidence of autistic disorder (AD) among 5,271 children in a neonatal intensive care unit in Japan found that 18 children were later diagnosed with AD, an incidence more than twice as high as previously reported. Children with AD had a significantly higher history of the meconium aspiration syndrome than the controls. (Author/DB)

  6. Grazing incidence optics; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

    Science.gov (United States)

    Osantowski, John F. (Editor); Van Speybroeck, Leon (Editor)

    1986-01-01

    Papers are presented on the diffraction-limited performance of grazing incidence optical systems; transverse ray aberrations of Wolter type 1 telescopes; hybrid X-ray telescope systems; surface characterization of grazing incidence optics in the extreme UV and X-ray regions; and the surface roughness properties of synchrotron radiation optics. Topics discussed include the simulation of free-abrasive grinding of grazing incidence mirrors with vertical-honing and flexible blades; mirrors for the Extreme Ultraviolet Explorer; the design and development of conical X-ray imaging mirrors; thermal loading considerations for synchrotron radiation mirrors; and grazing incidence optics for synchrotron radiation insertion-device beams. Consideration is given to the interpretation of glancing incidence scattering measurements; damage processes in short wavelength coated FEL optics; the replication of grain incidence optics; and the assembly and alignment of the Technology Mirror Assembly.

  7. The effects of laser beam incident angle and intensity distribution on Fabry-Perot etalon spectrum

    Science.gov (United States)

    Shen, Fahua; Wang, Yingying; Shi, Wenjuan; Chen, Ying; Liu, Mengling; Guo, Wenxin

    2017-11-01

    Fabry-Perot(F-P) etalon has important applications in laser detection, lidar and laser communication systems. In practical applications, the spectrum of the F-P etalon is affected by various factors, such as incident angle, divergence angle, spectral width, intensity distribution of the incident beam, absorption loss, surface defects of the plate and so on. The effects of the incident angle and the beam intensity distribution on F-P etalon spectrum are mainly analyzed. For the first time, taking into account both the beam incident angle and divergence angle, the precise analytical expression of the F-P etalon transmission spectrum is derived. For the Gaussian light intensity distribution, the precise analytical expression of the F-P etalon transmission spectrum is derived. The simulation analysis is carried out and the results are as follows. When the beam divergence angle is not zero, the incident angle increases, on the one hand, the center of the etalon spectrum is moved to the high frequency, and the frequency shift is linear with the square of the incident angle. The slope decreases with the increase of the divergence angle. On the other hand, resulting in peak reduction, spectral line broadening, and with the divergence angle increases, the more obvious the phenomenon. Considering the distribution of Gaussian light intensity, the spectrum of the etalon will be improved with the increase concentration of beam energy. On the one hand, the peak value is increased, the spectral line is narrowed and with the incidence angle increases, the degree of improvement is more obvious. On the one hand, the center of the spectrum moves toward the low frequency, but the larger the incident angle, the smaller the movement amount. The error of frequency discrimination or frequency locking by using the F-P etalon spectrum increases rapidly with the increase of the beam incident angle and beam divergence angle, and the Gaussian light intensity distribution beam can effectively

  8. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source.

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ∼95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ∼6.0%.

  9. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ˜95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ˜6.0%.

  10. Time domain referencing in intensity modulation fiber optic sensing systems

    Science.gov (United States)

    Adamovsky, G.

    1986-01-01

    Intensity modulation sensors are classified depending on the way in which the reference and signal channels are separated: in space, wavelength (frequency), or time domains. To implement the time domain referencing different types of fiber optic (FO) loops have been used. A pulse of short duration sent into the loop results in a series of pulses of different amplitudes. The information about the measured parameter is retrieved from the relative amplitudes of pulses in the same train.

  11. Optical diagnostics of mercury jet for an intense proton target.

    Science.gov (United States)

    Park, H; Tsang, T; Kirk, H G; Ladeinde, F; Graves, V B; Spampinato, P T; Carroll, A J; Titus, P H; McDonald, K T

    2008-04-01

    An optical diagnostic system is designed and constructed for imaging a free mercury jet interacting with a high intensity proton beam in a pulsed high-field solenoid magnet. The optical imaging system employs a backilluminated, laser shadow photography technique. Object illumination and image capture are transmitted through radiation-hard multimode optical fibers and flexible coherent imaging fibers. A retroreflected illumination design allows the entire passive imaging system to fit inside the bore of the solenoid magnet. A sequence of synchronized short laser light pulses are used to freeze the transient events, and the images are recorded by several high speed charge coupled devices. Quantitative and qualitative data analysis using image processing based on probability approach is described. The characteristics of free mercury jet as a high power target for beam-jet interaction at various levels of the magnetic induction field is reported in this paper.

  12. Intensity modulated radiotherapy for sinonasal malignancies with a focus on optic pathway preservation

    Directory of Open Access Journals (Sweden)

    Chi Alexander

    2013-01-01

    Full Text Available Abstract Purpose To assess if intensity-modulated radiotherapy (IMRT can possibly lead to improved local control and lower incidence of vision impairment/blindness in comparison to non-IMRT techniques when treating sinonasal malignancies; what is the most optimal dose constraints for the optic pathway; and the impact of different IMRT strategies on optic pathway sparing in this setting. Methods and materials A literature search in the PubMed databases was conducted in July, 2012. Results Clinical studies on IMRT and 2D/3D (2 dimensional/3 dimensional RT for sinonasal malignancies suggest improved local control and lower incidence of severe vision impairment with IMRT in comparison to non-IMRT techniques. As observed in the non-IMRT studies, blindness due to disease progression may occur despite a lack of severe toxicity possibly due to the difficulty of controlling locally very advanced disease with a dose ≤ 70 Gy. Concurrent chemotherapy’s influence on the the risk of severe optic toxicity after radiotherapy is unclear. A maximum dose of ≤ 54 Gy with conventional fractionation to the optic pathway may decrease the risk of blindness. Increased magnitude of intensity modulation through increasing the number of segments, beams, and using a combination of coplanar and non-coplanar arrangements may help increase dose conformality and optic pathway sparing when IMRT is used. Conclusion IMRT optimized with appropriate strategies may be the treatment of choice for the most optimal local control and optic pathway sparing when treating sinonasal malignancy.

  13. Angle of arrival detection through artificial neural network analysis of optical fiber intensity patterns

    Science.gov (United States)

    Thomas, Scott

    1990-12-01

    The optical sensors of United States Air Force reconnaissance vehicles, such as satellites, are subject to temporary or permanent blinding from hostile (or threat) laser radiation. By detecting and determining the angle of arrival (AOA) of the hostile radiation, the reconnaissance vehicle may be able to protect its optical sensors by taking evasive maneuvers or by shutting down the optical sensor (such as closing a shutter) until the threat has passed. In addition, the vehicle can relay information to its ground terminal allowing the intelligence community to determine the source of the hostile laser radiation. This thesis demonstrated that an intensity pattern out of a short piece of optical fiber could be used to determine the angle of arrival (AOA), to within 0.1 deg, of the incident laser energy on the front of the optical fiber. The optical fiber was a one-inch-long, 3mm-diameter, multimode, step-index, plastic fiber. The optical fiber was mounted to the front end of a charge injection device (CID) camera. The CID camera's angle with respect to the incident laser energy, a uniform amplitude plan wave, would be varied by a computer controlled rotational stage. The output of the CID camera was captured by Spiricon software. Captured outputs representing various AOAs were processed to provide template or test feature vectors. The processing method used a fast Fourier transform routine to create a 24 component low frequency feature vector. Two classification methodologies were used: a Eucledian distance method and a radial basis function neural network.

  14. The incidence of intensive care unit-acquired weakness syndromes: A systematic review.

    Science.gov (United States)

    Appleton, Richard Td; Kinsella, John; Quasim, Tara

    2015-05-01

    We conducted a literature review of the intensive care unit-acquired weakness syndromes (critical illness polyneuropathy, critical illness myopathy and critical illness neuromyopathy) with the primary objective of determining their incidence as a combined group. Studies were identified through MEDLINE, Embase, Cochrane Database and article reference list searches and were included if they evaluated the incidence of one or more of these conditions in an adult intensive care unit population. The incidence of an intensive care unit-acquired weakness syndrome in the included studies was 40% (1080/2686 patients, 95% confidence interval 38-42%). The intensive care unit populations included were heterogeneous though largely included patients receiving mechanical ventilation for seven or more days. Additional prespecified outcomes identified that the incidence of intensive care unit-acquired weakness varied with the diagnostic technique used, being lower with clinical (413/1276, 32%, 95% CI 30-35%) compared to electrophysiological techniques (749/1591, 47%, 95% CI 45-50%). Approximately a quarter of patients were not able to comply with clinical evaluation and this may be responsible for potential underreporting of this condition.

  15. Light intensity dependent optical rotation in azobenzene polymers

    Science.gov (United States)

    Ivanov, M.; Ilieva, D.; Petrova, T.; Dragostinova, V.; Todorov, T.; Nikolova, L.

    2006-05-01

    We investigate the self-induced rotation of the azimuth of light polarization ellipse in azobenzene polymers. It is initiated by the photoreorientation and ordering of the azobenzenes on illumination with elliptically polarized light resulting in the appearance of an optical axis whose direction is gradually rotated along the depth of the film. A macroscopic chiral structure is created with a pitch depending on light ellipticity and the photobirefringence ▵n in the successive layers of the film. In this work we make use of the fact that at elevated temperatures ▵n is very sensitive to light intensity. In our acrylic amorphous azobenzene polymer at temperatures 50-65°C the saturated values of ▵n are much higher for low intensity of the exciting light than for higher intensity. In this temperature range the polarization azimuth of monochromatic blue light with different intensity is rotated to a different angle after passing through the polymer film. This effect can be used for passive elements rotating the polarization azimuth depending on light intensity and for the formation of light beams with a space-variant polarization state.

  16. Fast Acting Optical Forces From Far Detuned, High Intensity Light

    Science.gov (United States)

    Corder, Christopher; Arnold, Brian; Hua, Xiang; Metcalf, Harold

    2015-05-01

    We are exploring fast acting, strong optical forces from standing wave light fields with high intensity and large detuning δ >> γ , where γ is the transition linewidth. We observe these fast acting forces on a time scale of a few times the excited state lifetime τ ≡ 1 / γ thus an atom may experience at most one or two spontaneous emission events. The dipole force is typically considered when the Rabi frequency Ω transverse velocity distribution of a beam of 23S He after a chosen interaction time with a perpendicular standing wave detuned from the 23S -->33P transition near 389 nm. The distribution shows velocity resonance effects that persist over a large range of Ω. We also simulate the experiment numerically using the Optical Bloch Equations and the results are consistent with our measurements. Supported by ONR and Dept. of Education GAANN

  17. Analysis of contributing factors associated to related patients safety incidents in Intensive Care Medicine.

    Science.gov (United States)

    Martín Delgado, M C; Merino de Cos, P; Sirgo Rodríguez, G; Álvarez Rodríguez, J; Gutiérrez Cía, I; Obón Azuara, B; Alonso Ovies, Á

    2015-01-01

    To explore contributing factors (CF) associated to related critical patients safety incidents. SYREC study pos hoc analysis. A total of 79 Intensive Care Departments were involved. The study sample consisted of 1.017 patients; 591 were affected by one or more incidents. The CF were categorized according to a proposed model by the National Patient Safety Agency from United Kingdom that was modified. Type, class and severity of the incidents was analyzed. A total 2,965 CF were reported (1,729 were associated to near miss and 1,236 to adverse events). The CF group more frequently reported were related patients factors. Individual factors were reported more frequently in near miss and task related CF in adverse events. CF were reported in all classes of incidents. The majority of CF were reported in the incidents classified such as less serious, even thought CF patients factors were associated to serious incidents. Individual factors were considered like avoidable and patients factors as unavoidable. The CF group more frequently reported were patient factors and was associated to more severe and unavoidable incidents. By contrast, individual factors were associated to less severe and avoidable incidents. In general, CF most frequently reported were associated to near miss. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  18. Incidence and aetiology of renal phosphate loss in patients with hypophosphatemia in the intensive care unit.

    NARCIS (Netherlands)

    Bech, A.P.; Blans, M.; Telting, D.; Boer, H. de

    2013-01-01

    BACKGROUND: Hypophosphatemia is a common finding in patients in the intensive care unit (ICU). Its cause is often poorly understood. PURPOSE: The aim of this study was to understand the incidence of renal phosphate loss in ICU-related hypophosphatemia, and to examine the role of phosphaturic

  19. [Incidence of multi-resistant bacteria in Intensive Care Units of Chilean hospitals].

    Science.gov (United States)

    Acuña, M Paz; Cifuentes, Marcela; Silva, Francisco; Rojas, Álvaro; Cerda, Jaime; Labarca, Jaime

    2017-12-01

    Incidence of multi-resistant bacteria is an indicator that permits better estimation of the magnitude of bacterial resistance in hospitals. To evaluate the incidence of relevant multi-drug resistant bacteria in intensive care units (ICUs) of Chile. Participating hospitals submitted information about the number of isolates from infected or colonized patients with 7 epidemiologically relevant multi-resistant bacteria in adult and pediatric ICUs between January 1, 2014 and October 31, 2015 and the number of bed days occupied in these units in the same period was requested. With these data incidence was calculated per 1,000 patient days for each unit. Information from 20 adults and 9 pediatric ICUs was reviewed. In adult ICUs the bacteria with the highest incidence were K. pneumoniae ESBL [4.72 × 1,000 patient day (1.21-13.89)] and oxacillin -resistant S. aureus [3.85 (0.71-12.66)]. In the pediatric units the incidence was lower, highlighting K. pneumoniae ESBL [2.71 (0-7.11)] and carbapenem -resistant P. aeruginosa [1.61 (0.31-9.25)]. Important differences between hospitals in the incidence of these bacteria were observed. Incidence of multi-resistant bacteria in adult ICU was significantly higher than in pediatric ICU for most of the studied bacterias.

  20. The Development of a Differential Deposition Technique for Figure Correction in Grazing Incidence Optics

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a physical-vapor-deposition coating technique to correct residual figure errors in grazing-incidence optics. The process involves...

  1. Near-surface electron acceleration during intense laser-solid interaction in the grazing incidence regime

    Science.gov (United States)

    Serebryakov, D. A.; Nerush, E. N.; Kostyukov, I. Yu.

    2017-12-01

    When a relativistically intense p-polarized laser pulse is grazingly incident onto a planar solid-state target, a slightly superluminal field structure is formed near the target surface due to the incident and reflected waves superposition. This field structure can both extract the electrons from the target and accelerate them. It is theoretically shown that the acceleration is possible and stable for a wide range of electron initial conditions. Particle-in-cell simulations confirm that this mechanism can actually take place for realistic parameters. As a result, the electron bunches with a charge of tens of nC and GeV-level energy can be produced using a laser intensity 1021-1022 W/cm2. It is also shown that the presence of a preplasma can improve acceleration, which becomes possible because of more efficient electron injection into the accelerating field structure.

  2. Factors influencing the incidence of sinusitis in nasopharyngeal carcinoma patients after intensity-modulated radiation therapy.

    Science.gov (United States)

    Su, Yan-xia; Liu, Lan-ping; Li, Lei; Li, Xu; Cao, Xiu-juan; Dong, Wei; Yang, Xin-hua; Xu, Jin; Yu, Shui; Hao, Jun-fang

    2014-12-01

    The aim of the study was to investigate the incidence of sinusitis in nasopharyngeal carcinoma (NPC) patients before and after intensity-modulated radiation therapy (IMRT) and to analyze factors associated with the incidence of sinusitis following IMRT. We retrospectively analyzed 283 NPC patients who received IMRT in our hospital from March 2009 to May 2011. The diagnostic criteria for sinusitis are based on computed tomography (CT) or magnetic resonance imaging (MRI) findings. CT or MRI scans were performed before and after IMRT to evaluate the incidence of sinusitis. Factors influencing the incidence of sinusitis were analyzed by log-rank univariate and logistic multivariate analyses. Among the 283 NPC patients, 128 (45.2 %) suffered from sinusitis before radiotherapy. The incidence rates of sinusitis in patients with T1, T2, T3, and T4 NPC before radiotherapy were 22.6, 37.5, 46.8, and 61.3 %, respectively (χ 2 = 14.548, p = 0.002). Among the 155 NPC patients without sinusitis before radiotherapy, the incidence rates of sinusitis at the end of radiotherapy and at 1, 3, 6, 9, 12, and 18 months after radiotherapy were 32.9, 43.2, 61.3, 68.4, 73.5, 69.7, and 61.3 %, respectively (χ 2 = 86.461, p < 0.001). Univariate analysis showed that T stage, invasion of the nasal cavity, nasal irrigation, and radiation dose to the nasopharynx were associated with the incidence of sinusitis in NPC patients after IMRT (p = 0.003, 0.006, 0.002, and 0.020). Multivariate analysis showed that T stage, invasion of the nasal cavity, and nasal irrigation were influential factors for the incidence of sinusitis in NPC patients after IMRT (p = 0.002, 0.002, and 0.000). There was a higher incidence of sinusitis with higher T stage among NPC patients before radiotherapy, and the incidence of sinusitis in NPC patients after IMRT was high (45.2 %). The incidence of sinusitis increased rapidly within the first 3 months after IMRT, and the number of sinusitis cases peaked at 6-9 months after

  3. Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

    2006-11-14

    This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silica high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 μm) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.

  4. An Evaluation of Grazing-Incidence Optics for Neutron Imaging

    Science.gov (United States)

    Gubarev, M. V.; Ramsey, B. D.; Engelhaupt, D. E.; Burgess, J.; Mildner, D. F. R.

    2007-01-01

    The focusing capabilities of neutron imaging optic based on the Wolter-1 geometry have been successfully demonstrated with a beam of long wavelength neutrons with low angular divergence.. A test mirror was fabricated using an electroformed nickel replication process at Marshall Space Flight Center. The neutron current density gain at the focal spot of the mirror is found to be at least 8 for neutron wavelengths in the range from 6 to 20 A. Possible applications of the optics are briefly discussed.

  5. Trends in prostate cancer incidence and mortality: an analysis of mortality change by screening intensity.

    Science.gov (United States)

    Coldman, Andrew J; Phillips, Norman; Pickles, Thomas A

    2003-01-07

    The rate of death from prostate cancer has recently declined in many areas of the world. Over the past 15 years prostate-specific antigen (PSA) screening has increased in popularity, which has resulted in increases in the incidence of prostate cancer. Over the same period there have been changes in the management of the disease and, in particular, the use of androgen ablation. We set out to examine the relation between changes in prostate cancer incidence (a surrogate for PSA screening) and subsequent changes in mortality in regions using common treatment recommendations. We used data from prostate cancer cases and deaths reported to the British Columbia Cancer Registry during 1985-1999 to examine trends in incidence and mortality in 88 small health areas (SHAs) among men aged 50-74 years. We conducted 2 analyses. In the first we classified the SHAs by intensity of PSA screening (low, medium or high) according to their ranked age-standardized incidence rate of prostate cancer in 1990-1994 and examined subsequent trends in prostate cancer mortality. In the second analysis we examined the SHA-specific relative change in prostate cancer incidence between 1985-1989 and 1990-1994 and correlated it with the relative change in mortality for cases diagnosed after 1990. Between 1985-1989 and 1990-1994 the incidence of prostate cancer increased by 53.2% and 14.6% among men aged 50-74 and those 75 and over respectively. Between 1985-1989 and 1995-1999 prostate cancer mortality declined by 17.6% and 7.9% in the 2 age groups respectively. Among men aged 50-74 years SHAs with low, middle and high levels of screening had respective increases in prostate cancer incidence of 5.4%, 53.6% and 70.5% between 1985-1989 and 1990-1994. Corresponding decreases in mortality between 1985-1989 and 1995-1999 were 28.9%, 18.0% and 13.5%. Mortality declines were greatest in SHAs with low screening levels (p = 0.032). Before 1990 prostate cancer mortality was similar in the 3 screening groups (p

  6. [Incidence of unplanned extubations in a neonatal intensive care unit. A before and after study].

    Science.gov (United States)

    Utrera Torres, M I; Moral Pumarega, M T; García Lara, N R; Melgar Bonís, A; Frías García, M E; Pallás Alonso, C R

    2014-05-01

    Unplanned extubations (UE) of mechanically ventilated newborns involves an undesirable increase in morbidity and mortality. A 2-stage study compared the frequency of UE in a Neonatal Intensive Care Unit before and after the implementation of a program of preventive measures to decrease UE. A before and after prospective study included all mechanically ventilated newborns participating in the 2 stage study from May-December 2011 and June-December 2012. In stage 1, the rate of UE per 100 intubated patient days was calculated and the characteristics of unplanned extubated newborns, circumstances of UE occurrence and need for re-intubation were studied. Consequently, a program of preventive measures for UE was designed and implemented, with the same variables being analysed in stage 2. No differences were found in patient characteristics during the two stages. Stage 1, incidence of UE was 5/100 intubated patient days; Stage 2, 4.5 UE/100 intubated patient days (P=.657). In both stages, most UE occurred during patient handling with re-intubation incidence at 77.4% and 67.7%, respectively. The combined rate of both stages during summer months of July, August and September was 6.2 UE/100 intubation days, in contrast with the remaining months of both stages: UE incidence rate, 3.4 UE/100 intubation days (p=.043). The implementation of a preventive measures program did not significantly reduce the incidence of UE. The summer period showed the highest incidence of UE. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  7. X-ray microscopy using grazing-incidence reflection optics

    International Nuclear Information System (INIS)

    Price, R.H.

    1981-01-01

    The Kirkpatrick-Baez microscopes are described along with their role as the workhorse of the x-ray imaging devices. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics

  8. Incidence and factors related to delirium in an intensive care unit.

    Science.gov (United States)

    Mori, Satomi; Takeda, Juliana Rumy Tsuchihashi; Carrara, Fernanda Souza Angotti; Cohrs, Cibelli Rizzo; Zanei, Suely Sueko Viski; Whitaker, Iveth Yamaguchi

    2016-01-01

    To identify the incidence of delirium, compare the demographic and clinical characteristics of patients with and without delirium, and verify factors related to delirium in critical care patients. Prospective cohort with a sample made up of patients hospitalized in the Intensive Care Unit (ICU) of a university hospital. Demographic, clinical variables and evaluation with the Confusion Assessment Method for Intensive Care Unit to identify delirium were processed to the univariate analysis and logistic regression to identify factors related to the occurrence of delirium. Of the total 149 patients in the sample, 69 (46.3%) presented delirium during ICU stay, whose mean age, severity of illness and length of ICU stay were statistically higher. The factors related to delirium were: age, midazolam, morphine and propofol. Results showed high incidence of ICU delirium associated with older age, use of sedatives and analgesics, emphasizing the need for relevant nursing care to prevent and identify early, patients presenting these characteristics. Identificar a incidência de delirium, comparar as características demográficas e clínicas dos pacientes com e sem delirium e verificar os fatores relacionados ao delirium em pacientes internados em Unidade de Terapia Intensiva (UTI). Coorte prospectiva, cuja amostra foi constituída de pacientes internados em UTI de um hospital universitário. Variáveis demográficas, clínicas e da avaliação com o Confusion Assessment Method for Intensive Care Unit para identificação de delirium foram processadas para análise univariada, e regressão logística para identificar fatores relacionados à ocorrência do delirium. Do total de 149 pacientes da amostra, 69 (46,3%) apresentaram delirium durante a internação na UTI, observando-se que a média da idade, o índice de gravidade e o tempo de permanência nas UTI foram estatisticamente maiores. Os fatores relacionados ao delirium foram: idade, midazolam, morfina e propofol. Os

  9. The Incidence And Risk Factors Nosocomial Pneumonia In A Neuromedical Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Devragudi TS

    2001-01-01

    Full Text Available This retrospective study examined the incidence and factors influencing the occurrence of nonsocomial pneumonia (NP in a neuromedical intensive care unit (NICU. Of the 57 patients admitted to the NICU over one year, 26% developed nosocomial pneumonia. It was observed that the infected patients were significantly older than the noninfected (43+15 vs 22+18 years; p<0.001, had a longer NICU stay (33+31 vs 18+18 days: p=0.05 and needed longer duration of mechanical ventilation (20+25 vs 9 + 12 days: P<0.05. Patients with neuromuscular diseases had a trend towards higher incidence of NP than those with encephalopathy and therapeutic interventions such as plasmapheresis, blood transfusion and inotropic therapy did not influence the incidence of nosocomial pneumonia. The NICU mortality was not significantly influenced by nosocomial pneumonia. Pseudomonas aerugenosa was the predominant organism responsible for pneumonia. Nine percent of the tracheobronchial isolates were resistant to the routinely-tested antibiotics. In conclusion, nosocornial pneumonia is a common complication in a NICU and while it increases the duration of NICU stay, mortality appears to be uninfluenced.

  10. Differential Deposition for Surface Figure Corrections in Grazing Incidence X-Ray Optics

    Science.gov (United States)

    Ramsey, Brian D.; Kilaru, Kiranmayee; Atkins, Carolyn; Gubarev, Mikhail V.; Broadway, David M.

    2015-01-01

    Differential deposition corrects the low- and mid- spatial-frequency deviations in the axial figure of Wolter-type grazing incidence X-ray optics. Figure deviations is one of the major contributors to the achievable angular resolution. Minimizing figure errors can significantly improve the imaging quality of X-ray optics. Material of varying thickness is selectively deposited, using DC magnetron sputtering, along the length of optic to minimize figure deviations. Custom vacuum chambers are built that can incorporate full-shell and segmented Xray optics. Metrology data of preliminary corrections on a single meridian of full-shell x-ray optics show an improvement of mid-spatial frequencies from 6.7 to 1.8 arc secs HPD. Efforts are in progress to correct a full-shell and segmented optics and to verify angular-resolution improvement with X-ray testing.

  11. Aplanatic telescopes based on Schwarzschild optical configuration: from grazing incidence Wolter-like x-ray optics to Cherenkov two-mirror normal incidence telescopes

    Science.gov (United States)

    Sironi, Giorgia

    2017-09-01

    At the beginning of XX century Karl Schwarzschild defined a method to design large-field aplanatic telescopes based on the use of two aspheric mirrors. The approach was then refined by Couder (1926) who, in order to correct for the astigmatic aberration, introduced a curvature of the focal plane. By the way, the realization of normal-incidence telescopes implementing the Schwarzschild aplanatic configuration has been historically limited by the lack of technological solutions to manufacture and test aspheric mirrors. On the other hand, the Schwarzschild solution was recovered for the realization of coma-free X-ray grazing incidence optics. Wolter-like grazing incidence systems are indeed free of spherical aberration, but still suffer from coma and higher order aberrations degrading the imaging capability for off-axis sources. The application of the Schwarzschild's solution to X-ray optics allowed Wolter to define an optical system that exactly obeys the Abbe sine condition, eliminating coma completely. Therefore these systems are named Wolter-Schwarzschild telescopes and have been used to implement wide-field X-ray telescopes like the ROSAT WFC and the SOHO X-ray telescope. Starting from this approach, a new class of X-ray optical system was proposed by Burrows, Burg and Giacconi assuming polynomials numerically optimized to get a flat field of view response and applied by Conconi to the wide field x-ray telescope (WFXT) design. The Schwarzschild-Couder solution has been recently re-discovered for the application to normal-incidence Cherenkov telescopes, thanks to the suggestion by Vassiliev and collaborators. The Italian Institute for Astrophysics (INAF) realized the first Cherenkov telescope based on the polynomial variation of the Schwarzschild configuration (the so-called ASTRI telescope). Its optical qualification was successfully completed in 2016, demonstrating the suitability of the Schwarzschild-like configuration for the Cherenkov astronomy requirements

  12. Micropositioning in MAXIMUM: Photoemission microscopy with normal incident optics (abstract)

    International Nuclear Information System (INIS)

    Ng, W.; Wallace, J.P.; Ray-Chandhuri, A.K.; Capasso, C.; Cerrina, F.

    1992-01-01

    We discuss the two critical micropositioning systems implemented on the latest version of MAXIMUM at the Wisconsin Synchrotron Radiation Center. MAXIMUM is an undulator-based x-ray photoelectron microscope. The microscope utilizes a set of multilayer-coated normal incident Schwarzchild objective to produce a submicron focus spot. The sample is rastered across the spot and photoelectrons emitted from the sample are collected to form an image. The Schwarschild objective is mounted such that it is vibrationally isolated from the vacuum chamber. The two mirrors are mounted on a three axis flexural pivot stage actuated by inchworm motors. This system allows in situ fine alignment of the objective and it is totally decoupled from any vacuum forces. The inchworm motors will also act as clamps when the objective is aligned. The sample scanning is done by a flexural hinge stage actuated by an in-house design PZT stack. The stage has a range of 100 μmx100 μmx5 μm with a resolution of 100 A. The system is totally UHV compatible. A laser interferometer is used for sample position feedback. This work was supported by NSF, DOE

  13. Grazing-incidence optical magnetic recording with super-resolution.

    Science.gov (United States)

    Scheunert, Gunther; Cohen, Sidney R; Kullock, René; McCarron, Ryan; Rechev, Katya; Kaplan-Ashiri, Ifat; Bitton, Ora; Dawson, Paul; Hecht, Bert; Oron, Dan

    2017-01-01

    Heat-assisted magnetic recording (HAMR) is often considered the next major step in the storage industry: it is predicted to increase the storage capacity, the read/write speed and the data lifetime of future hard disk drives. However, despite more than a decade of development work, the reliability is still a prime concern. Featuring an inherently fragile surface-plasmon resonator as a highly localized heat source, as part of a near-field transducer (NFT), the current industry concepts still fail to deliver drives with sufficient lifetime. This study presents a method to aid conventional NFT-designs by additional grazing-incidence laser illumination, which may open an alternative route to high-durability HAMR. Magnetic switching is demonstrated on consumer-grade CoCrPt perpendicular magnetic recording media using a green and a near-infrared diode laser. Sub-500 nm magnetic features are written in the absence of a NFT in a moderate bias field of only μ 0 H = 0.3 T with individual laser pulses of 40 mW power and 50 ns duration with a laser spot size of 3 μm (short axis) at the sample surface - six times larger than the magnetic features. Herein, the presence of a nanoscopic object, i.e., the tip of an atomic force microscope in the focus of the laser at the sample surface, has no impact on the recorded magnetic features - thus suggesting full compatibility with NFT-HAMR.

  14. Intensities of incident and transmitted ultraviolet-a rays through gafchromic films

    Directory of Open Access Journals (Sweden)

    Toshizo Katsuda

    2017-01-01

    Full Text Available Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission intensity. Gafchromic EBT3 films were suitable to be used in this study because non-UV protection layers are present on both sides of the film. The film is placed between UV-A ray light-emitting diodes and a probe of a UV meter. Gafchromic EBT3 films were irradiated by UV-A rays for up to 60 min. Data for analysis were obtained in the subsequent 60 min. Images from before and after UV-A irradiation were subtracted. When using 375 nm UV-A, the mean ± standard deviation (SD of the pixel values in the subtracted image was remarkably high (11,194.15 ± 586.63. However, the UV-A transmissivity remained constant throughout the 60 min irradiation period. The mean ± SD UV-A transmission intensity was 184.48 ± 0.50 μm/cm2. Our findings demonstrate that color density changes in Gafchromic EBT3 films do not affect their UV-A transmission. Therefore, Gafchromic films were irradiated by UV-A rays as a preexposure.

  15. Grazing-incidence optical magnetic recording with super-resolution

    Directory of Open Access Journals (Sweden)

    Gunther Scheunert

    2017-01-01

    Full Text Available Heat-assisted magnetic recording (HAMR is often considered the next major step in the storage industry: it is predicted to increase the storage capacity, the read/write speed and the data lifetime of future hard disk drives. However, despite more than a decade of development work, the reliability is still a prime concern. Featuring an inherently fragile surface-plasmon resonator as a highly localized heat source, as part of a near-field transducer (NFT, the current industry concepts still fail to deliver drives with sufficient lifetime. This study presents a method to aid conventional NFT-designs by additional grazing-incidence laser illumination, which may open an alternative route to high-durability HAMR. Magnetic switching is demonstrated on consumer-grade CoCrPt perpendicular magnetic recording media using a green and a near-infrared diode laser. Sub-500 nm magnetic features are written in the absence of a NFT in a moderate bias field of only μ0H = 0.3 T with individual laser pulses of 40 mW power and 50 ns duration with a laser spot size of 3 μm (short axis at the sample surface – six times larger than the magnetic features. Herein, the presence of a nanoscopic object, i.e., the tip of an atomic force microscope in the focus of the laser at the sample surface, has no impact on the recorded magnetic features – thus suggesting full compatibility with NFT-HAMR.

  16. Intensity-based fibre-optic sensing system using contrast modulation of subcarrier interference pattern

    Science.gov (United States)

    Adamovsky, G.; Sherer, T. N.; Maitland, D. J.

    1989-01-01

    A novel technique to compensate for unwanted intensity losses in a fiber-optic sensing system is described. The technique involves a continuous sinusoidal modulation of the light source intensity at radio frequencies and an intensity sensor placed in an unbalanced interferometer. The system shows high sensitivity and stability.

  17. Equi-intensity distribution of optical reflectance in a fibrous turbid medium.

    Science.gov (United States)

    Shuaib, Ali; Yao, Gang

    2010-02-10

    Light propagation in a fibrous anisotropic scattering medium is quite different from that in an isotropic medium. Both the anisotropic diffuse equation (ADE) and the continuous time random walk (CTRW) theory predict that the equi-intensity profiles of the surface reflectance have an elliptical shape in a fibrous turbid medium. In this study, we simulated the spatially resolved surface reflectance in a fibrous sample using a Monte Carlo model. A parametric equation was used to quantitatively characterize the geometric profiles of the reflectance patterns. The results indicated that the equi-intensity profiles of surface reflectance had elliptical shapes only when evaluated at distances far away from the incident point. The length ratio of the two orthogonal axes of the ellipse was not affected by the sample optical properties when the ratio of reduced scattering coefficients along the two axes is the same. But the relationship between the aforementioned two ratios was different from the predication of ADE theory. Only for fibers of small sizes did the fitted axes ratios approach the values predicted from the ADE theory.

  18. Incidence and preventability of adverse events requiring intensive care admission: a systematic review.

    Science.gov (United States)

    Vlayen, Annemie; Verelst, Sandra; Bekkering, Geertruida E; Schrooten, Ward; Hellings, Johan; Claes, Neree

    2012-04-01

    Adverse events are unintended patient injuries or complications that arise from health care management resulting in death, disability or prolonged hospital stay. Adverse events that require critical care are a considerable financial burden to the health care system, but also their global impact on patients and society is probably underestimated. The objectives of this systematic review were to synthesize the best available evidence regarding the estimates of the incidence and preventability of adverse events that necessitate intensive care admission, to determine the type and consequences [mortality, length of intensive care unit (ICU) stay and costs] of these adverse events. MEDLINE (from 1966 to present), EMBASE (from 1974 to present) and CENTRAL (version 1-2010) were searched for studies reporting on unplanned admissions on ICUs. Several other sources were searched for additional studies. Only quantitative studies that used chart review for the detection of adverse events requiring intensive care admission were considered for eligibility. For the purposes of this systematic review, ICUs were defined as specialized hospital facilities which provide continuous monitoring and intensive care for acutely ill patients. Studies that were published in the English, Dutch, German, French or Spanish language were eligible for inclusion. Two reviewers independently extracted data and assessed the methodological quality of the included studies. A total of 27 studies were reviewed. Meta-analysis of the data was not appropriate because of methodological and statistical heterogeneity between studies; therefore, results are presented in a descriptive way. The percentage of surgical and medical adverse events that required ICU admission ranged from 1.1% to 37.2%. ICU readmissions varied from 0% to 18.3%. Preventability of the adverse events varied from 17% to 76.5%. Preventable adverse events are further synthesized by type of event. Consequences of the adverse events included a

  19. Incidence of drug interactions in intensive care units in tertiary care settings: Classification, facts and measures.

    Science.gov (United States)

    Hasnain, Hina; Ali, Huma; Zafar, Farya; Sial, Ali Akbar; Alam, Shazia; Beg, Anwar Ejaz; Bushra, Rabia; Rizvi, Mehwish; Khan, Maqsood Ahmed; Shareef, Huma; Naqvi, Ghazala R; Tariq, Anum

    2018-03-01

    Drug-drug interactions (DDIs) are extremely significant concern, particularly in sensitive population including pediatric and geriatric. Propensity for the development of DDIs is high in patients admitted at intensive care units (ICU). This study was conducted to evaluate the DDIs incidence, facts and measures in ICU. From a total of 150 cases studied for ICU patients, with the mean age of 56.37±12.45 years, 55.33% were male and the rest were female 44.66%. The demographic information like age, gender and main diagnosis details of study participants that were extracted from the patients' clinical record. A statistically significant association between the drug interaction and the number of drugs prescribed per prescription was observed (pICU attributed high risk of adverse reactions due to use of multiple interventions to treat severity of disease condition. Such studies may be used to develop an effective tool for the diagnosis and management of DDIs.

  20. Incidence of and Risk Factors for Mastoiditis after Intensity Modulated Radiotherapy in Nasopharyngeal Carcinoma.

    Directory of Open Access Journals (Sweden)

    Ji-Jin Yao

    Full Text Available To report the incidence of and risk factors for mastoiditis after intensity-modulated radiotherapy (IMRT in nasopharyngeal carcinoma (NPC.Retrospective analysis of pretreatment and follow-up magnetic resonance imaging (MRI data for 451 patients with NPC treated with IMRT at a single institution. The diagnosis of mastoiditis was based on MRI; otomastoid opacification was rated as Grade 0 (none, 1 (mild, 2 (moderate or 3 (severe by radiologists blinded to clinical outcome. This study mainly focused on severe mastoiditis; patients were divided into three groups: the G0M (Grade 0 mastoiditis before treatment group, G1-2M (Grade 1 to 2 mastoiditis before treatment group and G3M (Grade 3 mastoiditis before treatment group. The software SAS9.3 program was used to analyze the data.For the entire cohort, the incidence of Grade 3 mastoiditis was 20% before treatment and 31%, 19% and 17% at 3, 12 and 24 months after radiotherapy, respectively. In the G0M group, the incidence of severe mastoiditis was 0% before treatment and 23%, 15% and 13% at 3, 12 and 24 months after radiotherapy, respectively. Multivariate analysis revealed T category (OR=0.68, 95% CI = 0.469 to 0.984, time (OR=0.668, 95% CI = 0.59 to 0.757 and chemotherapy (OR=0.598, 95% CI = 0.343 to 0.934 were independent factors associated with severe mastoiditis in the G0M group after treatment.Mastoiditis, as diagnosed by MRI, occurs as a progressive process that regresses and resolves over time in patients with NPC treated using IMRT.

  1. Correlation and squeezing for optical transistor and intensity for router applications in Pr3+:YSO.

    Science.gov (United States)

    Khan, Ghulam Abbas; Li, Changbiao; Raza, Faizan; Ahmed, Noor; Mahesar, Abdul Rasheed; Ahmed, Irfan; Zhang, Yanpeng

    2017-06-14

    We realized an optical transistor and router utilizing multi-order fluorescence and spontaneous parametric four-wave mixing. Specifically, the optical routing action was derived from the results of splitting in the intensity signal due to a dressing effect, whereas the transistor as a switch and amplifier was realized by a switching correlation and squeezing via a nonlinear phase. A substantial enhancement of the optical contrast was observed for switching applications using correlation and squeezing contrary to the intensity signal. Moreover, the controlling parameters were also configured to devise a control mechanism for the optical transistor and router.

  2. Incidence of anaerobic bacteria in patients with suspected pneumonia in surgical Intensive Care Unit.

    Science.gov (United States)

    Clavier, T; Gouin, P; Frebourg, N; Rey, N; Royon, V; Bergis, A; Hobeika, S; Dureuil, B; Veber, B

    2014-10-01

    Few studies have investigated the incidence of pulmonary anaerobes in a specific population in surgical Intensive Care Unit (ICU). The objective of this work was to determine the incidence of anaerobes in surgical ICU patients with suspected pneumonia. This was a prospective observational, single-center study. Analysis was based on data collected over 30 months from the surgical ICU of a tertiary care hospital (Rouen University Hospital), including data on risk factors for anaerobes in the lungs. Patients with suspected pneumonia (community-acquired or nosocomial) were included. Bacteriological sampling was performed by protected distal bronchial sampling (PDBS) with minilavage under bronchoscopy. Aerobic and anaerobic cultures were performed for each sample. Clinicians were only aware of aerobic results. Univariate and multivariate statistical analysis compared groups with and without anaerobes. A total of 134 samples were obtained from 117 patients. Surgery was performed on 74 patients (63.2%), within 24 hours of admission. Fifty-four patients (46.2%) had a chest trauma and 20 patients (17.1%) were admitted for a digestive pathology. Average age was 53.6±20.9 years and sex ratio was 5.9 (100 men/17 women). Average SAPS II was 41.6±15.1, median length of ICU stay was 23 days (25th percentile=13, 75th percentile=33), and median duration of mechanical ventilation was 21 days (25th percentile=11, 75th percentile=28). Mortality rate in ICU was 14.5%. After sampling, diagnosis of pneumonia was confirmed in 70 cases (52.2%). Anaerobe cultures were positive in 11 samples taken from 11 different patients (overall incidence 8.2%). Aerobic bacteria were also involved in 9 patients (81.8%). In univariate analysis, enteral feeding (P=0.02) and absence of catecholamines at time of sampling (P=0.003) were significantly associated with the presence of anaerobes in PDBS. Enteral nutrition was also found to be a risk factor in multivariate analysis (OR=11.8, 95% CI [1.36 to 102

  3. Fiber-optical sensor with intensity compensation model in college teaching of physics experiment

    Science.gov (United States)

    Su, Liping; Zhang, Yang; Li, Kun; Zhang, Yu

    2017-08-01

    Optical fiber sensor technology is one of the main contents of modern information technology, which has a very important position in modern science and technology. Fiber optic sensor experiment can improve students' enthusiasm and broaden their horizons in college physics experiment. In this paper the main structure and working principle of fiberoptical sensor with intensity compensation model are introduced. And thus fiber-optical sensor with intensity compensation model is applied to measure micro displacement of Young's modulus measurement experiment and metal linear expansion coefficient measurement experiment in the college physics experiment. Results indicate that the measurement accuracy of micro displacement is higher than that of the traditional methods using fiber-optical sensor with intensity compensation model. Meanwhile this measurement method makes the students understand on the optical fiber, sensor and nature of micro displacement measurement method and makes each experiment strengthen relationship and compatibility, which provides a new idea for the reform of experimental teaching.

  4. Weakness acquired in the intensive care unit. Incidence, risk factors and their association with inspiratory weakness. Observational cohort study.

    Science.gov (United States)

    Ballve, Ladislao Pablo Diaz; Dargains, Nahuel; Inchaustegui, José García Urrutia; Bratos, Antonella; Percaz, Maria de Los Milagros; Ardariz, Cesar Bueno; Cagide, Sabrina; Balestrieri, Carolina; Gamarra, Claudio; Paz, Dario; Rotela, Eliana; Muller, Sebastian; Bustos, Fernando; Castro, Ricard Aranda; Settembrino, Esteban

    2017-01-01

    This paper sought to determine the accumulated incidence and analyze the risk factors associated with the development of weakness acquired in the intensive care unit and its relationship to inspiratory weakness. We conducted a prospective cohort study at a single center, multipurpose medical-surgical intensive care unit. We included adult patients who required mechanical ventilation ≥ 24 hours between July 2014 and January 2016. No interventions were performed. Demographic data, clinical diagnoses, the factors related to the development of intensive care unit -acquired weakness, and maximal inspiratory pressure were recorded. Of the 111 patients included, 66 developed intensive care unit -acquired weakness, with a cumulative incidence of 40.5% over 18 months. The group with intensive care unit-acquired weakness were older (55.9 ± 17.6 versus 45.8 ± 16.7), required more mechanical ventilation (7 [4 - 10] days versus 4 [2 - 7.3] days), and spent more time in the intensive care unit (15.5 [9.2 - 22.8] days versus 9 [6 - 14] days). More patients presented with delirium (68% versus 39%), hyperglycemia > 3 days (84% versus 59%), and positive balance > 3 days (73.3% versus 37%). All comparisons were significant at p 5 days as independent predictors of intensive care unit-acquired weakness. Low maximal inspiratory pressure was associated with intensive care unit-acquired weakness (p intensive care unit-acquired weakness. The intensive care unit acquired weakness is a condition with a high incidence in our environment. The development of intensive care unit-acquired weakness was associated with age, delirium, hyperglycemia, and mechanical ventilation > 5 days. The maximum inspiratory pressure value of ≥ 36cmH2O was associated with a high diagnostic value to exclude the presence of intensive care unit -acquired weakness.

  5. Effect of Gastric Acid Suppressant Prophylaxis on Incidence of Gastrointestinal Bleeding in Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Tahoora Abdollahi

    2016-11-01

    Full Text Available Background: Critically ill children admitted to pediatric intensive care unit (PICU are at increased risk of gastrointestinal bleeding due to stress related mucosal injury. Reducing gastric acid by acid suppressant medication is the accepted prophylaxis treatment, but there is not any definitive guideline for using prophylaxis in PICU patients. The present study aimed to assess the effect of Proton Pump Inhibitor (PPI and H2 Blocker (H2B prophylaxis on gastrointestinal bleeding in admitted patients of PICU, Mashhad- Iran.Materials and Methods: In this study, 100 patients admitted in PICU divided into two equal groups on the first day of admission. They received ranitidine or pantoprazole as prophylaxis of stress ulcer. Those patients who had history of gastrointestinal bleeding or coagulation disorder were excluded. 100 PICU patients who had not received prophylaxis during last 6 months retrospectively evaluated as control of the study. Data were collected as demographic characteristics, admission reason, definitive diagnosis, receiving corticosteroid and mechanical ventilation in each patient. Gastrointestinal bleeding (hematemesis, coffee ground aspirate, and melena and clinically significant gastrointestinal bleeding were daily monitored. Data analyzed through descriptive statistical tests, Chi-square, logistic regression, t-test and using SPSS-16 software.Results: Among 204 patients (control group=105 and case group=99, incidence of gastrointestinal bleeding (GB was 13.2% in which 6.9% of cases presented with clinically significant gastrointestinal bleeding (CSGB. Loss of consciousness and respiratory distress were the main reason of admission. There was no significant differences between the incidence of (GB and (CSGB in experimental and control groups (P>0.05 as well as ranitidine and pantoprazole prophylaxis (P>0.05. Significant risk factors of (GB were mechanical ventilation and loss of consciousness and corticosteroid therapy

  6. Incidence, characteristics, and survival following cardiopulmonary resuscitation in the quaternary neonatal intensive care unit.

    Science.gov (United States)

    Foglia, Elizabeth E; Langeveld, Robert; Heimall, Lauren; Deveney, Alyson; Ades, Anne; Jensen, Erik A; Nadkarni, Vinay M

    2017-01-01

    The contemporary characteristics and outcomes of cardiopulmonary resuscitation (CPR) in the neonatal intensive care unit (NICU) are poorly described. The objectives of this study were to determine the incidence, interventions, and outcomes of CPR in a quaternary referral NICU. Retrospective observational study of infants who received chest compressions for resuscitation in the Children's Hospital of Philadelphia NICU between April 1, 2011 and June 30, 2015. Patient, event, and survival characteristics were abstracted from the medical record and the hospital-wide resuscitation database. The primary outcome was survival to hospital discharge. Univariable and multivariable analyses were performed to identify patient and event factors associated with survival to discharge. There were 1.2 CPR events per 1000 patient days. CPR was performed in 113 of 5046 (2.2%) infants admitted to the NICU during the study period. The median duration of chest compressions was 2min (interquartile range 1, 6min). Adrenaline was administered in 34 (30%) CPR events. Of 113 infants with at least one CPR event, 69 (61%) survived to hospital discharge. Factors independently associated with decreased survival to hospital discharge were inotrope treatment prior to CPR (adjusted Odds Ratio [aOR] 0.14, 95% Confidence Interval [CI] 0.04, 0.54), and adrenaline administration during CPR (aOR 0.14, 95% CI 0.04, 0.50). Although it was not uncommon, the incidence of CPR was low (CPR and adrenaline administration during CPR were less likely to survive to hospital discharge. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Incidence of acute kidney injury in the neonatal intensive care unit.

    Science.gov (United States)

    Youssef, Doaa; Abd-Elrahman, Hadeel; Shehab, Mohamed M; Abd-Elrheem, Mohamed

    2015-01-01

    The aim of this work is to study the incidence of acute kidney injury (AKI) in neonates admitted to the neonatal intensive care unit (NICU) over a six-month period from September 2011 to March 2012. This prospective study was performed on 250 neonates admitted to the NICU at the Children's Hospital, Faculty of Medicine, Zagazig University. All neonates were subjected to detailed history taking, including pre-natal, natal and post-natal history, with stress on symptoms suggestive of AKI. All neonates were examined thoroughly and the following investigations were performed: Blood urea nitrogen (BUN), serum creatinine, sodium, potassium, calcium, complete blood count, C-reactive protein, arterial blood gases, urine sodium and urine creatinine. AKI was diagnosed in 27 cases (10.8%), including 12 females and 15 males. 40.7% of the AKI cases were born after full-term pregnancy while 59.3% were pre-term babies. 29.6% of the AKI cases had oliguria, and there was male sex predominance, with a male-female ratio of 1.3:1. The cause of AKI was pre-renal in 96.3% and intrinsic renal in 3.7% of the cases. The predisposing factors for AKI were sepsis in 63% of the cases, respiratory distress syndrome in 55.6%, mechanical ventilation in 51.9%, peri-natal asphyxia in 18.5%, dehydration in 14.8%, surgical operation in 11.1%, congenital heart disease in 7.4%, sub-galeal hematoma in 3.7%, polycythemia in 3.7% and intra-ventricular hemorrhage in 3.7% of the cases. Our data suggest that pre-renal failure was the most common form of AKI in our patients. Early recognition of risk factors such as sepsis, peri-natal asphyxia or peri-operative problems and rapid effective treatment of contributing conditions will reduce the incidence of AKI in the neonatal period.

  8. Dynamics of atomic clusters in intense optical fields of ultrashort ...

    Indian Academy of Sciences (India)

    This alternation, or charge flip- ping, results in a net cycle averaged force on the ions at the poles. Electron-ion collisions within the spheri- cal plasma also contribute to the charge flipping such that, after one optical cycle, the net charge at the 'top' of the sphere is not the same as that at the 'bottom'. Moreover, on the average ...

  9. Weighted Local Intensity Fusion Method for Variational Optical Flow Estimation

    NARCIS (Netherlands)

    Tu, Z.; Poppe, R.W.; Veltkamp, R.C.

    2016-01-01

    Estimating a dense motion field of successive video frames is a fundamental problem in image processing. The multi-scale variational optical flow method is a critical technique that addresses this issue. Despite the considerable progress over the past decades, there are still some challenges such as

  10. Intensity-carrying modes in Raman and Raman optical activity spectroscopy.

    Science.gov (United States)

    Luber, Sandra; Reiher, Markus

    2009-08-24

    We describe a quantum-chemical approach for the determination of modes with maximum Raman and Raman optical activity (ROA) intensity by maximizing the intensities with respect to the Raman and Raman optical activity intensity, respectively, which is shown to lead to eigenvalue equations. The intensity-carrying modes are in general hypothetical modes and do not directly correspond to a certain normal mode in the spectrum. However, they provide information about those molecular distortions leading to intense bands in the spectrum. Modes with maximum Raman intensity are presented for propane-1,3-dione, propane-1,3-dionate, and Lambda-tris(propane-1,3-dionato)cobalt(III). Moreover, the mode with highest ROA intensity is examined for this chiral cobalt complex and also for the (chiral) amino acid L-tryptophan. The Raman and ROA high-intensity modes are an optimal starting guess for intensity-tracking calculations, in which selectively normal modes with high Raman or ROA intensity are converged. We present the first Raman and ROA intensity-tracking calculations. These reveal a high potential for large molecules, for which the selective calculation of normal modes with high intensity is desirable in view of the large computational effort required for the calculation of Raman and ROA polarizability property tensors.

  11. Incidence and aetiology of renal phosphate loss in patients with hypophosphatemia in the intensive care unit.

    Science.gov (United States)

    Bech, Anneke; Blans, Michiel; Telting, Darryl; de Boer, Hans

    2013-10-01

    Hypophosphatemia is a common finding in patients in the intensive care unit (ICU). Its cause is often poorly understood. The aim of this study was to understand the incidence of renal phosphate loss in ICU-related hypophosphatemia, and to examine the role of phosphaturic hormones in its etiology. Plasma phosphate levels were measured on day 1, 3, 5 and 7 in 290 consecutive patients admitted to the ICU. Renal phosphate handling and phosphaturic hormones were studied in a subset of patients with phosphate levels Renal phosphate loss was defined as a TmP/gfr patients. This mainly occurred within the first 3 days of stay and in patients with serum creatinine levels Renal phosphate loss was present in 80% of patients who developed hypophosphatemia, and was not related to serum levels of parathyroid hormone (PTH), PTH-related protein (PTH-rp), fibroblast growth factor 23 (FGF-23), or calcitonin. Hypophosphatemia in the ICU is commonly associated with renal phosphate loss. It mainly occurs within the first 3 days of admission, in particular in patients with preserved renal function. Renal phosphate loss is not explained by elevated PTH, PTH-rp, FGF-23 or calcitonin levels.

  12. Precision 3-D microscopy with intensity modulated fibre optic scanners

    Science.gov (United States)

    Olmos, P.

    2016-01-01

    Optical 3-D imagers constitute a family of precision and useful instruments, easily available on the market in a wide variety of configurations and performances. However, besides their cost they usually provide an image of the object (i.e. a more or less faithful representation of the reality) instead of a truly object's reconstruction. Depending on the detailed working principles of the equipment, this reconstruction may become a challenging task. Here a very simple yet reliable device is described; it is able to form images of opaque objects by illuminating them with an optical fibre and collecting the reflected light with another fibre. Its 3-D capability comes from the spatial filtering imposed by the fibres together with their movement (scanning) along the three directions: transversal (surface) and vertical. This unsophisticated approach allows one to model accurately the entire optical process and to perform the desired reconstruction, finding that information about the surface which is of interest: its profile and its reflectance, ultimately related to the type of material.

  13. Plasma q -plate for generation and manipulation of intense optical vortices

    Science.gov (United States)

    Qu, Kenan; Jia, Qing; Fisch, Nathaniel J.

    2017-11-01

    An optical vortex is a light wave with a twisting wavefront around its propagation axis and null intensity in the beam center. Its unique spatial structure of field lends itself to a broad range of applications, including optical communication, quantum information, superresolution microscopy, and multidimensional manipulation of particles. However, accessible intensity of optical vortices have been limited to material ionization threshold. This limitation might be removed by using the plasma medium. Here we propose the design of suitably magnetized plasmas which, functioning as a q -plate, leads to a direct conversion from a high-intensity Gaussian beam into a twisted beam. A circularly polarized laser beam in the plasma accumulates an azimuthal-angle-dependent phase shift and hence forms a twisting wavefront. Our three-dimensional particle-in-cell simulations demonstrate extremely high-power conversion efficiency. The plasma q -plate can work in a large range of frequencies spanning from terahertz to the optical domain.

  14. Suppression of phase-induced intensity noise in fibre optic delay line signal processors using an optical phase modulation technique.

    Science.gov (United States)

    Chan, Erwin H W

    2010-10-11

    A technique that can suppress the dominant phase-induced intensity noise in fibre optic delay line signal processors is presented. It is based on phase modulation of the optical carrier to distribute the phase noise at the information band into a high frequency band which can be filtered out. This technique is suitable for suppressing the phase noise in various delay line structures and for integrating in the conventional fibre optic links. It can also suppress the coherent interference effect at the same time. A model for predicting the amount of phase noise reduction in various delay line structures using the optical phase modulation technique is presented for the first time and is experimentally verified. Experimental results demonstrate the technique can achieve a large phase noise reduction in various fibre optic delay line signal processors.

  15. Optical Intensity Modulation in an LiNbO3 Slab-Coupled Waveguide

    Directory of Open Access Journals (Sweden)

    Yalin Lu

    2008-01-01

    Full Text Available Optical intensity modulation has been demonstrated through switching the optical beam between the main core waveguide and a closely attached leaky slab waveguide by applying a low-voltage electrical field. Theory for simulating such an LiNbO3 slab-coupled waveguide structure was suggested, and the result indicates the possibility of making the spatial guiding mode large, circular and symmetric, which further allows the potential to significantly reduce the coupling losses with adjacent lasers and optical networks. Optical intensity modulation using electro-optic effect was experimentally demonstrated in a 5 cm long waveguide fabricated by using a procedure of soft proton exchange and then an overgrowth of thin LN film on top of a c-cut LiNbO3 wafer.

  16. Risk factors for the incidence of delirium in cerebrovascular patients in a Neurosurgery Intensive Care Unit: A prospective study.

    Science.gov (United States)

    Wang, Jun; Ji, Yuanyuan; Wang, Ning; Chen, Wenjin; Bao, Yuehong; Qin, Qinpu; Xiao, Qian; Li, Shulan

    2018-01-01

    To explore the incidence of delirium in cerebrovascular patients admitted in our Neurosurgery Intensive Care Unit and analyse the risk factors leading to delirium. Delirium is one of the most common mental disorders in general hospitals, but the incidence of different kinds of diseases and studies varies. Cerebrovascular patients in our Neurosurgery Intensive Care Unit are high-risk groups for delirium; identifying risk factors for delirium and taking early interventions are crucial for patient prognosis. A prospective study. A convenience sampling method was used to collect data from 128 patients in the Neurosurgery Intensive Care Unit of Xuanwu Hospital, Capital Medical University, Beijing, China, between May 2016-January 2017. Researchers used Confusion Assessment Method for the Intensive Care Unit (Chinese version) to assess each patient's delirium statement twice a day at regular times. We also collected other independent data variables and followed up the short-term clinical outcomes daily. On the basis of Confusion Assessment Method for the Intensive Care Unit evaluation, patients were divided into a delirium group and a nondelirium group. The prevalence of delirium among the 128 patients was 42.2%. Multivariate analysis showed that severity of illness, fever, the use of physical restraints and sleep deprivation were independent predictors of delirium in cerebrovascular patients in the Neurosurgery Intensive Care Unit. Cerebrovascular patients in the Neurosurgery Intensive Care Unit with a critical condition, fever or use of physical restraints or experiencing sleep deprivation were more prone to delirium. Cerebrovascular patients in the Neurosurgery Intensive Care Unit showed a high incidence of delirium. There are many risk factors leading to delirium, some of which are independent predictors of intensive care delirium. Patients with delirium will suffer various adverse effects upon their short-term clinical outcomes. Therefore, nurses should pay close

  17. Incidence of acute kidney injury in the neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Doaa Youssef

    2015-01-01

    Full Text Available The aim of this work is to study the incidence of acute kidney injury (AKI in neonates admitted to the neonatal intensive care unit (NICU over a six-month period from September 2011 to March 2012. This prospective study was performed on 250 neonates admitted to the NICU at the Children′s Hospital, Faculty of Medicine, Zagazig University. All neonates were subjected to detailed history taking, including pre-natal, natal and post-natal history, with stress on symptoms suggestive of AKI. All neonates were examined thoroughly and the following investigations were performed: Blood urea nitrogen (BUN, serum creatinine, sodium, potassium, calcium, complete blood count, C-reactive protein, arterial blood gases, urine sodium and urine creatinine. AKI was diagnosed in 27 cases (10.8%, including 12 females and 15 males. 40.7% of the AKI cases were born after full-term pregnancy while 59.3% were pre-term babies. 29.6% of the AKI cases had oliguria, and there was male sex predominance, with a male-female ratio of 1.3:1. The cause of AKI was pre-renal in 96.3% and intrinsic renal in 3.7% of the cases. The predisposing factors for AKI were sepsis in 63% of the cases, respiratory distress syndrome in 55.6%, mechanical ventilation in 51.9%, peri-natal asphyxia in 18.5%, dehydration in 14.8%, surgical operation in 11.1%, congenital heart disease in 7.4%, sub-galeal hematoma in 3.7%, polycythemia in 3.7% and intra-ventricular hemorrhage in 3.7% of the cases. Our data suggest that pre-renal failure was the most common form of AKI in our patients. Early recognition of risk factors such as sepsis, peri-natal asphyxia or peri-operative problems and rapid effective treatment of contributing conditions will reduce the incidence of AKI in the neonatal period.

  18. Optical generation of intense ultrashort magnetic pulses at the nanoscale

    Science.gov (United States)

    Tsiatmas, Anagnostis; Atmatzakis, Evangelos; Papasimakis, Nikitas; Fedotov, Vassili; Luk'yanchuk, Boris; Zheludev, Nikolay I.; García de Abajo, F. Javier

    2013-11-01

    Generating, controlling and sensing strong magnetic fields at ever shorter time and length scales is important for both fundamental solid-state physics and technological applications such as magnetic data recording. Here, we propose a scheme for producing strong ultrashort magnetic pulses localized at the nanoscale. We show that a bimetallic nanoring illuminated by femtosecond laser pulses responds with transient thermoelectric currents of picosecond duration, which in turn induce Tesla-scale magnetic fields in the ring cavity. Our method provides a practical way of generating intense nanoscale magnetic fields with great potential for materials characterization, terahertz radiation generation and data storage applications.

  19. Partially coherent X-ray wavefront propagation simulations including grazing-incidence focusing optics.

    Science.gov (United States)

    Canestrari, Niccolo; Chubar, Oleg; Reininger, Ruben

    2014-09-01

    X-ray beamlines in modern synchrotron radiation sources make extensive use of grazing-incidence reflective optics, in particular Kirkpatrick-Baez elliptical mirror systems. These systems can focus the incoming X-rays down to nanometer-scale spot sizes while maintaining relatively large acceptance apertures and high flux in the focused radiation spots. In low-emittance storage rings and in free-electron lasers such systems are used with partially or even nearly fully coherent X-ray beams and often target diffraction-limited resolution. Therefore, their accurate simulation and modeling has to be performed within the framework of wave optics. Here the implementation and benchmarking of a wave-optics method for the simulation of grazing-incidence mirrors based on the local stationary-phase approximation or, in other words, the local propagation of the radiation electric field along geometrical rays, is described. The proposed method is CPU-efficient and fully compatible with the numerical methods of Fourier optics. It has been implemented in the Synchrotron Radiation Workshop (SRW) computer code and extensively tested against the geometrical ray-tracing code SHADOW. The test simulations have been performed for cases without and with diffraction at mirror apertures, including cases where the grazing-incidence mirrors can be hardly approximated by ideal lenses. Good agreement between the SRW and SHADOW simulation results is observed in the cases without diffraction. The differences between the simulation results obtained by the two codes in diffraction-dominated cases for illumination with fully or partially coherent radiation are analyzed and interpreted. The application of the new method for the simulation of wavefront propagation through a high-resolution X-ray microspectroscopy beamline at the National Synchrotron Light Source II (Brookhaven National Laboratory, USA) is demonstrated.

  20. Peculiarities of the Self-Action of Inclined Wave Beams Incident on a Discrete System of Optical Fibers

    Science.gov (United States)

    Litvak, A. G.; Mironov, V. A.; Skobelev, S. A.; Smirnov, L. A.

    2018-01-01

    Based on a discrete nonlinear Schrödinger equation (DNSE), we studied analytically and numerically the peculiarities of the self-action of one-dimensional quasi-optic wave beams injected into a spatially inhomogeneous medium consisting of a set of equidistant mutually coupled optical fibers. A variational approach allowing the prediction of the global evolution of localized fields with the initially plane phase front was developed. The self-consistent equations are obtained for the main parameters of such beams (the position of the center of mass, the effective width, and linear and quadratic phase-front corrections) in the aberrationless approximation. The case of radiation incident on a periodic system of nonlinear optical fibers at an angle to the axis oriented along them is analyzed in detail. It is shown that for the radiation power exceeding a critical value, the self-focusing of the wave field is observed, which is accompanied by the shift of the intensity maximum followed by the concentration of the main part of radiation only in one of the structural elements of the array under study. In this case, the beams propagate along paths considerably different from linear and the direction of their propagation changes compared to the initial direction. Asymptotic expressions are found that allow us to estimate the self-focusing length and to determine quite accurately the final position of a point with the maximum field amplitude after radiation trapping a channel. The results of the qualitative study of the possible self-channeling regimes for wave beams in a system of weakly coupled optical fibers in the aberrationless approximation are compared with the results of direct numerical simulations within the DNSE framework.

  1. Influences of optical-spectrum errors on excess relative intensity noise in a fiber-optic gyroscope

    Science.gov (United States)

    Zheng, Yue; Zhang, Chunxi; Li, Lijing

    2018-03-01

    The excess relative intensity noise (RIN) generated from broadband sources degrades the angular-random-walk performance of a fiber-optic gyroscope dramatically. Many methods have been proposed and managed to suppress the excess RIN. However, the properties of the excess RIN under the influences of different optical errors in the fiber-optic gyroscope have not been systematically investigated. Therefore, it is difficult for the existing RIN-suppression methods to achieve the optimal results in practice. In this work, the influences of different optical-spectrum errors on the power spectral density of the excess RIN are theoretically analyzed. In particular, the properties of the excess RIN affected by the raised-cosine-type ripples in the optical spectrum are elaborately investigated. Experimental measurements of the excess RIN corresponding to different optical-spectrum errors are in good agreement with our theoretical analysis, demonstrating its validity. This work provides a comprehensive understanding of the properties of the excess RIN under the influences of different optical-spectrum errors. Potentially, it can be utilized to optimize the configurations of the existing RIN-suppression methods by accurately evaluating the power spectral density of the excess RIN.

  2. Selective detection of Escherichia coli by imaging of the light intensity transmitted through an optical disk

    Science.gov (United States)

    Shiramizu, Hideyuki; Kuroda, Chiaki; Ohki, Yoshimichi; Shima, Takayuki; Wang, Xiaomin; Fujimaki, Makoto

    2018-03-01

    We have developed an optical disk system for imaging transmitted light from Escherichia coli dispersed on an optical disk. When E. coli was stained using Bismarck brown, the transmittance was found to decrease in images obtained at λ = 405 nm. The results indicate that transmittance imaging is suitable for finding the difference in light intensity between stained and unstained E. coli, whereas the reflectance images were scarcely changed by staining. Therefore, E. coli can be selectively discriminated from abiotic contaminants using transmittance imaging.

  3. Incidence of MRI intensity changes in the knee meniscus. Comparing asymptomatic and symptomatic knees without meniscal lesion

    International Nuclear Information System (INIS)

    Nozaki, Hiroyuki; Iso, Yoshinori; Furufu, Teruo; Suguro, Toru

    2004-01-01

    MRI has become the most frequently used imaging technique in diagnosing knee joint diseases. However, a number of factors may change the intensity of the meniscus on MR images, even in normal knees. The question remains when and to what degree the change in intensity appears with age, how aging is related to MR image grades, and how the development of symptoms is related to a change in intensity. To answer these questions, the present study investigated MR images of the menisci of asymptomatic volunteers and patients with knee diseases other than meniscal lesions to determine intrameniscal intensity changes. 163 knees in 133 subjects who underwent MRI for the knee joint (s) were examined. The coronal and the sagittal planes were imaged with T1 weighted imaging and GE slice thickness of 5 mm. MR images were classified as Grade 0 to 4. In knees of patients under 40 years of age, a change in intensity was only rarely observed in the menisci of normal knees, though it was frequently observed in those of symptomatic knees. By contrast, in the knees of patients 40 years or older, a change in intensity was frequently observed in the menisci of both normal and symptomatic knees. MRI is useful because of its convenience, low invasiveness, and high diagnostic ability. However, MR images of the meniscus should be read carefully, because the incidence of changes in intensity increases with aging or inflammation, and in symptomatic knees, the intensity change is occasionally exaggerated resulting in incorrect diagnosis. (author)

  4. Heart rate-based training intensity and its impact on injury incidence among elite-level professional soccer players.

    Science.gov (United States)

    Owen, Adam L; Forsyth, Jacky J; Wong, Del P; Dellal, Alexandre; Connelly, Sean P; Chamari, Karim

    2015-06-01

    Elite-level professional soccer players are suggested to have increased physical, technical, tactical, and psychological capabilities when compared with their subelite counterparts. Ensuring these players remain at the elite level generally involves training many different bodily systems to a high intensity or level within a short duration. This study aimed to examine whether an increase in training volume at high-intensity levels was related to injury incidence, or increased the odds of sustaining an injury. Training intensity was monitored through time spent in high-intensity (T-HI) and very high-intensity (T-VHI) zones of 85-injuries were recorded over 2 consecutive seasons. Twenty-three, elite professional male soccer players (mean ± SD age, 25.6 ± 4.6 years; stature, 181.8 ± 6.8 cm; and body mass, 79.3 ± 8.1 kg) were studied throughout the 2-years span of the investigation. The results showed a mean total injury incidence of 18.8 (95% confidence interval [CI], 14.7-22.9) injuries per 1,000 hours of exposure. Significant correlations were found between training volume at T-HI and injury incidence (r = 0.57, p = 0.005). Further analysis revealed how players achieving more time in the T-VHI zone during training increased the odds of sustaining a match injury (odds ratio = 1.87; 95% CI, 1.12-3.12, p = 0.02) but did not increase the odds of sustaining a training injury. Reducing the number of competitive match injuries among elite-level professional players may be possible if greater focus is placed on the training intensity and volume over a period of time ensuring the potential reduction of fatigue or overuse injuries. In addition, it is important to understand the optimal training load at which adaptation occurs without raising the risk of injury.

  5. Symmetry consideration in zero loop-area Sagnac interferometry at oblique incidence for detecting magneto-optic Kerr effects.

    Science.gov (United States)

    Zhu, X D

    2017-08-01

    I present a detailed account of a zero loop-area Sagnac interferometer operated at oblique incidence for detecting magneto-optic Kerr effects arising from a magnetized sample. In particular, I describe the symmetry consideration and various optical arrangements available to such an interferometer that enables measurements of magneto-optic effects due to both in-plane and out-of-plane magnetization of the sample with optimizable signal-to-noise ratios.

  6. Persistent postoperative pain after cardiac surgery: a systematic review with meta-analysis regarding incidence and pain intensity.

    Science.gov (United States)

    Guimarães-Pereira, Luís; Reis, Pedro; Abelha, Fernando; Azevedo, Luís Filipe; Castro-Lopes, José Manuel

    2017-10-01

    Persistent postoperative pain (PPP) has been described as a complication of cardiac surgery (CS). We aimed to study PPP after CS (PPPCS) by conducting a systematic review of the literature regarding its incidence, intensity, location, and the presence of neuropathic pain, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. The review comprised 3 phases: a methodological assessment of 6 different databases identifying potential articles and screening for inclusion criteria by 2 independent reviewers; data extraction; and study quality assessment. Meta-analysis was used to estimate the pooled incidence rates using a random effects model. We have identified 442 potentially relevant studies through database searching. A total of 23 studies (involving 11,057 patients) met our inclusion criteria. Persistent postoperative pain affects 37% patients in the first 6 months after CS, and it remains present more than 2 years after CS in 17%. The reported incidence of PPP during the first 6 months after CS increased in recent years. Globally, approximately half of the patients with PPPCS reported moderate to severe pain. Chest is the main location of PPPCS followed by the leg; neuropathic pain is present in the majority of the patients. This is the first systematic review and meta-analysis to provide estimates regarding incidence and intensity of PPPCS, which elucidates its relevance. There is an urgent need for adequate treatment and follow-up in patients with PPPCS.

  7. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposures

    NARCIS (Netherlands)

    Khorsand, A.R.; Sobierajski, R.; Louis, Eric; Bruijn, S.; Gleeson, A.; van de Kruijs, Robbert Wilhelmus Elisabeth; Gullikson, E.M.; Bijkerk, Frederik

    2010-01-01

    We investigated single shot damage of Mo/Si multilayer coatings exposed to the intense fs XUV radiation at the Free-electron LASer facility in Hamburg - FLASH. The interaction process was studied in situ by XUV reflectometry, time resolved optical microscopy, and “post-mortem” by

  8. Excitation of random intense single-cycle light-pulse chains in optical fiber

    International Nuclear Information System (INIS)

    Ding, Y C; Zhang, F L; Gao, J B; Chen, Z Y; Lin, C Y; Yu, M Y

    2014-01-01

    Excitation of intense periodic single-cycle light pulses in a stochastic background arising from continuous wave stimulated Brillouin scattering (SBS) in a long optical fiber with weak optical feedback is found experimentally and modeled theoretically. Such intense light-pulse chains occur randomly and the optical feedback is a requirement for their excitation. The probability of these forms, among the large number of experimental output signals with identifiable waveforms, appearing is only about 3%, with the remainder exhibiting regular SBS characteristics. It is also found that pulses with low period numbers appear more frequently and the probability distribution for their occurrence in terms of the pulse power is roughly L-shaped, like that for rogue waves. The results from a three-wave-coupling model for SBS including feedback phase control agree well qualitatively with the observed phenomena. (paper)

  9. Respiration rate detection based on intensity modulation using plastic optical fiber

    Directory of Open Access Journals (Sweden)

    Mohd Anwar Zawawi

    2017-01-01

    Full Text Available This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  10. Respiration rate detection based on intensity modulation using plastic optical fiber

    Science.gov (United States)

    Anwar, Zawawi Mohd; Ziran Nurul Sufia, Nor; Hadi, Manap

    2017-11-01

    This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  11. Optimization of Grazing Incidence Optics for Wide-Field X-Ray Survey Imaging

    Science.gov (United States)

    Roming, P. W. A.; Burrows, D. N.; Garmire, G. P.; Roush, W. B.

    1999-12-01

    Optimization of wide-field X-ray optics could greatly enhance X-ray surveys. Discussions of optimizing wide-field X-ray optics, with field-of-views less-than 1.1 degree-squared, have been made previously in the literature. However, very little has been published about the optimizing of wide-field X-ray optics with larger fields-of-view. We have been working on the design of a wide-field (3.1 degree-squared field-of-view), short focal length (190.5 cm), grazing incidence mirror shell set, with a desired rms image spot size of 15 arcsec. The baseline design incorporates Wolter I type mirror shells with polynomial perturbations applied to the grazing incidence surface. By optimizing the polynomial, the rms image spot size can be minimized for a large range of grazing angles. The overall minimization technique is to efficiently optimize the polynomial coefficients that directly influence the angular resolution, without stepping through the entire multidimensional coefficient space. The multidimensional minimization techniques that have been investigated include: the downhill simplex method; the coupling of genetic algorithms with full and fractional, including Plackett-Burman, factorial designs; and the coupling of genetic algorithms with Box-Behnken and central composite response surface designs. We have also examined the use of neural networks, coupled with genetic algorithms, as a method of multidimensional minimization. Investigations of backpropagation, probabilistic (PNN), general regression (GRNN), and group method of data handling (GMDH) neural networks have been made. We report our findings to date. This research is funded by NASA grant #NAG5-5093.

  12. Incidence and Risk Factors of Retinopathy of Prematurity in Two Neonatal Intensive Care Units in North and South China

    Science.gov (United States)

    Chen, Yi; Xun, Deng; Wang, Ya-Cong; Wang, Bin; Geng, Shao-Hui; Chen, Hui; Li, Yan-Tao; Li, Xiao-Xin

    2015-01-01

    Background: To investigate the incidence and risk factors of retinopathy of prematurity (ROP) in two Neonatal Intensive Care Units in North and South of China, respectively. Methods: We studied data concerning 472 infants with gestational age (GA) ≤34 weeks or birth weight (BW) ≤2000 g who were admitted to the Zhujiang Hospital of Southern Medical University and the Fourth Hospital of Shijiazhuang between January 1, 2011 and December 31, 2011. Clinical information about perinatal neonates was collected and was confirmed by reviewing medical charts. The incidence and severity of ROP were assessed in the screened population. Main outcome measures are the incidence and severity of ROP. The relationship of clinical risk factors and the development of ROP were analyzed. Results: The overall incidence of ROP was 12.7%, and the overall incidence of type 1 ROP was 2.3%; 9.4% of infants in Zhujiang Hospital had ROP compared to 15.0% infants in the Fourth Hospital of Shijiazhuang developed ROP, and the difference is statistically significant. ROP was significantly associated with GA (odds ratio [OR]: 0.77 [0.62–0.95], P = 0.015), BW (OR: 0.998 [0.996–0.999], P = 0.008), maternal supplemental oxygen administration before and during delivery (OR: 4.27 [1.21–15.10], P = 0.024) and preeclampsia (OR: 6.07 [1.73–21.36] P = 0.005). The risk factors for ROP are different in two hospitals. In Zhujiang Hospital, BW is the independent risk factors for ROP while GA, BW and preeclampsia in the Fourth Hospital in Shijiazhuang Conclusions: Retinopathy of prematurity incidence is different based on area. Incidence of ROP is still high in China. More efforts need to prevent ROP. PMID:25836612

  13. Incidence and long-term outcomes of adult patients with diabetic ketoacidosis admitted to intensive care: A retrospective cohort study.

    Science.gov (United States)

    Ramaesh, Aksha

    2016-08-01

    Diabetic ketoacidosis is a life-threatening but avoidable complication of diabetes mellitus often managed in intensive care units. The risk of emergency hospital readmission in patients surviving an intensive care unit episode of diabetic ketoacidosis is unknown. We aimed to report the cumulative incidence of emergency hospital readmission and costs in all patients surviving an intensive care unit episode of diabetic ketoacidosis in Scotland. We used a national six-year cohort of survivors of first diabetic ketoacidosis admissions to Scottish intensive care units (1 January 2005-31 December 2010) identified in the Scottish Intensive Care Society Audit Group registry linked to acute hospital and death records (follow-up censored 31 December 2010). Diabetic ketoacidosis-related emergency readmissions were identified using International Classification of Disease-10 codes. During the study period, 386 patients were admitted to intensive care units in Scotland with diabetic ketoacidosis (admission rate 1.5/100,000 Scottish population). Median age was 44 (IQR 29-56); 51% male; 55% required no organ support on admission. Mortality after intensive care unit admission was 8% at 30 days, 18% at one year, and 35% at five years. A total of 349 patients survived their first intensive care unit diabetic ketoacidosis admission [mean (SD) age 42.5 (18.1) years; 50.4% women; 46.1% required ≥1 organ support]. Following hospital discharge, cumulative incidence of 90-day, one-year, and five-year diabetic ketoacidosis readmission (all-cause readmission) was 13.8% (31.8%), 29.7% (58.9%) and 46.4% (82.6%). Diabetic ketoacidosis in patients requiring intensive care unit admission is associated with high risk of long-term mortality and high hospital costs. An understanding of the precipitating causes of diabetic ketoacidosis in patients admitted to intensive care units may allow patients who are at high risk to be targeted, potentially reducing future morbidity and the substantial burden

  14. Incidence of infection for preterm twins cared for in cobedding in the neonatal intensive-care unit.

    Science.gov (United States)

    LaMar, Kim; Dowling, Donna A

    2006-01-01

    To describe the incidence of infection in a group of cobedded preterm twin infants and compare it to the incidence of infection in a cohort of preterm twin infants cared for in the same institution prior to the onset of cobedding. Retrospective descriptive design. Tertiary, referral neonatal intensive-care unit in the Midwest. Preterm twin infants between 23 and 35 weeks gestational age. Data from 1997 to 2001 (cobedding) compared to data from 1992 to 1996 (no cobedding). Infection as evidenced by positive blood, cerebrospinal fluid, or urine culture or radiographic evidence of pneumonia or necrotizing enterocolitis. Independent samples t test found the cobedded and non-cobedded infants to be homogenous in demographic data. A 2-way analysis of variance demonstrated no significant effects for cobedded infants on number of sepsis evaluations or number of positive blood cultures. There was a statistically significant difference for number of positive blood cultures at discharge reflecting the increased number of positive blood cultures in the non-cobedded infants. Finally, there were no statistically significant differences found between cobedded and non-cobedded for the presence of pneumonia or necrotizing enterocolitis. Cobedding of preterm twins cared for in the intensive-care nursery was not associated with an increased incidence of infection. Prospective studies are needed on cobedding before a change in practice is implemented.

  15. Incidence and outcome from adult cardiac arrest occurring in the intensive care unit: a systematic review of the literature.

    Science.gov (United States)

    Efendijev, Ilmar; Nurmi, Jouni; Castrén, Maaret; Skrifvars, Markus B

    2014-04-01

    Significant amount of data on the incidence and outcome of out-of-hospital and in-hospital cardiac arrest have been published. Cardiac arrest occurring in the intensive care unit has received less attention. To evaluate and summarize current knowledge of intensive care unit cardiac arrest including quality of data, and results focusing on incidence and patient outcome. We conducted a literature search of the PubMed, CINAHL and Cochrane databases with the following search terms (medical subheadings): heart arrest AND intensive care unit OR critical care OR critical care nursing OR monitored bed OR monitored ward OR monitored patient. We included articles published from the 1st of January 1990 till 31st of December 2012. After exclusion of all duplicates and irrelevant articles we evaluated quality of studies using a predefined quality assessment score and summarized outcome data. The initial search yielded 794 articles of which 780 were excluded. Three papers were added after a manual search of the eligible studies' references. One paper was identified manually from the literature published after our initial search was completed, thus the final sample consisted of 18 papers. Of the studies included thirteen were retrospective, two based on prospective registries and three were focused prospective studies. All except two studies were from a single institution. Six studies reported the incidence of intensive care unit cardiac arrest, which varied from 5.6 to 78.1 cardiac arrests per 1000 intensive care unit admissions. The most frequently reported initial cardiac arrest rhythms were non-shockable. Patient outcome was variable with survival to hospital discharge being in the range of 0-79% and long-term survival ranging from 1 to 69%. Nine studies reported neurological status of survivors, which was mostly favorable, either no neurological sequelae or cerebral performance score mostly of 1-2. Studies focusing on post cardiac surgery patients reported the best long

  16. Temperature-Insensitive Fibre-Optic Acceleration Sensor Based on Intensity-Referenced Fibre Bragg Gratings

    International Nuclear Information System (INIS)

    Li-Qun, Sun; Bo, Dong; Yong-Xin, Wang; LALLY, Evan; An-Bo, Wang

    2008-01-01

    A temperature-insensitive acceleration sensor using two fibre Bragg gratings (FBGs), based on reflection spectrum intensity modulation and optical power detection, is proposed and demonstrated. A cantilever beam is used to generate acceleration-induced axial strain along two sensing gratings, which are glued on the two opposite surfaces of the beam. Because the two gratings operate within the linear spectral range of a light source, formed by a thermally-tunable extrinsic Fabry-Perot optical filter, the intensity difference of the two reflections from the gratings is proportional to the acceleration applied. This eliminates the need for sophisticated wavelength interrogation of the gratings, and it also endows the sensor with immunity to temperature variation. Compared with a commercial micromachined accelerometer, the sensor is proven to be capable of accurately detecting acceleration

  17. The impact of normal saline on the incidence of exposure keratopathy in patients hospitalized in intensive care units

    Directory of Open Access Journals (Sweden)

    Zohreh Davoodabady

    2018-01-01

    Full Text Available Background: Patients in the intensive care unit (ICU have impaired ocular protective mechanisms that lead to an increased risk of ocular surface diseases including exposure keratopathy (EK. This study was designed to evaluate the effect of normal saline (NS on the incidence and severity of EK in critically ill patients. Materials and Methods: This single-blind randomized controlled trial was conducted on 50 patients admitted to ICUs. The participants were selected through purposive sampling. One eye of each patient, randomly was allocated to intervention group (standard care with NS and the other eye to control group (standard care. In each patient, one eye (control group randomly received standard care and the other eye (intervention group received NS every 6 h in addition to standard care. The presence and severity of keratopathy was assessed daily until day 7 of hospitalization using fluorescein and an ophthalmoscope with cobalt blue filter. Chi-square test was used for statistical analysis in SPSS software. Results: Before the study ( first day there were no statistically significant differences in the incidence and severity of EK between groups. Although, the incidence and severity of EK after the study (7th day was higher in the intervention group compared to the control group, their differences were not statistically significant. Although, the incidence and severity of EK, from the 1st day until the 7th, increased within both groups, this increase was statistically significant only in the intervention (NS group. Conclusions: The use of NS as eye care in patients hospitalized in ICUs can increase the incidence and severity of EK and is not recommended.

  18. Changes in the Incidence of Candidiasis in Neonatal Intensive Care Units

    Science.gov (United States)

    Aliaga, Sofia; Clark, Reese H.; Laughon, Matthew; Walsh, Thomas J.; Hope, William W.; Benjamin, Daniel K.; Kaufman, David; Arrieta, Antonio; Benjamin, Daniel K.

    2014-01-01

    OBJECTIVE: Neonatal invasive candidiasis is associated with significant morbidity and mortality. We describe the association between invasive candidiasis and changes in use of antifungal prophylaxis, empirical antifungal therapy, and broad-spectrum antibacterial antibiotics over time. METHODS: We examined data from 709 325 infants at 322 NICUs managed by the Pediatrix Medical Group from 1997 to 2010. We determined the cumulative incidence of invasive candidiasis and use of antifungal prophylaxis, broad-spectrum antibacterial antibiotics, and empirical antifungal therapy by year. RESULTS: We identified 2063 (0.3%) infants with 2101 episodes of invasive candidiasis. Over the study period, the annual incidence of invasive candidiasis decreased from 3.6 episodes per 1000 patients to 1.4 episodes per 1000 patients among all infants, from 24.2 to 11.6 episodes per 1000 patients among infants with a birth weight of 750–999 g, and from 82.7 to 23.8 episodes per 1000 patients among infants with a birth weight candidiasis in the NICU decreased over the 14-year study period. Increased use of fluconazole prophylaxis and empirical antifungal therapy, along with decreased use of broad-spectrum antibacterial antibiotics, may have contributed to this observation. PMID:24446441

  19. INCIDENCE OF INFECTION ASSOCIATED TO CENTRAL VENOUS CATHETERS IN A NEONATAL INTENSIVE CARE UNIT

    Directory of Open Access Journals (Sweden)

    Adriana Teixeira Reis

    2011-07-01

    Full Text Available Trata-se de um estudo transversal e retrospectivo que objetivou  identificar o tipo de cateter venoso central (CVC mais utilizado na Unidade de Terapia Intensiva Neonatal (UTIN de um hospital público universitário do estado do Rio de Janeiro, estratificado por peso de nascimento e apresentar as densidades de incidência de infecção associadas aos dispositivos.  Os dados foram coletados através de análise documental nos meses de junho e julho de 2008, referentes ao período de julho a dezembro de 2007, totalizando um registro de 712 cateteres-dia. Foi verificado o cateter central de inserção periférica (CCIP/PICC como o dispositivo mais utilizado na unidade, seguido do cateter venoso umbilical e da dissecção venosa. A densidade de incidência das infecções primárias da corrente sanguínea foi cerca de oito vezes maior nos recém-nascidos com peso ≤ 1.500g, sendo o cateter umbilical o dispositivo mais associado a essas infecções.

  20. Single-intensity-recording optical encryption technique based on phase retrieval algorithm and QR code

    Science.gov (United States)

    Wang, Zhi-peng; Zhang, Shuai; Liu, Hong-zhao; Qin, Yi

    2014-12-01

    Based on phase retrieval algorithm and QR code, a new optical encryption technology that only needs to record one intensity distribution is proposed. In this encryption process, firstly, the QR code is generated from the information to be encrypted; and then the generated QR code is placed in the input plane of 4-f system to have a double random phase encryption. For only one intensity distribution in the output plane is recorded as the ciphertext, the encryption process is greatly simplified. In the decryption process, the corresponding QR code is retrieved using phase retrieval algorithm. A priori information about QR code is used as support constraint in the input plane, which helps solve the stagnation problem. The original information can be recovered without distortion by scanning the QR code. The encryption process can be implemented either optically or digitally, and the decryption process uses digital method. In addition, the security of the proposed optical encryption technology is analyzed. Theoretical analysis and computer simulations show that this optical encryption system is invulnerable to various attacks, and suitable for harsh transmission conditions.

  1. Coupled thermal-optic effects and electrical modulation mechanism of birefringence crystal with Gaussian laser incidence

    International Nuclear Information System (INIS)

    Zhou Ji; He Zhi-Hong; Ma Yu; Dong Shi-Kui

    2015-01-01

    We study the Gaussian laser transmission in lithium niobate crystal (LiNbO 3 ) by using the finite element method to solve the electromagnetic field’s frequency domain equation and energy equation. The heat generated is identified by calculating the transmission loss of the electromagnetic wave in the birefringence crystal, and the calculated value of the heat generated is substituted into the energy equation. The electromagnetic wave’s energy losses induced by its multiple refractions and reflections along with the resulting physical property changes of the lithium niobate crystal are considered. Influences of ambient temperature and heat transfer coefficient on refraction and walk-off angles of O-ray and E-ray in the cases of different incident powers and crystal thicknesses are analyzed. The E-ray electrical modulation instances, in which the polarized light waveform is adjusted to the rated condition via an applied electrical field in the cases of different ambient temperatures and heat transfer coefficients, are provided to conclude that there is a correlation between ambient temperature and applied electrical field intensity and a correlation between surface heat transfer coefficient and applied electrical field intensity. The applicable electrical modulation ranges without crystal breakdown are proposed. The study shows that the electrical field-adjustable heat transfer coefficient range becomes narrow as the incident power decreases and wide as the crystal thickness increases. In addition, it is pointed out that controlling the ambient temperature is easier than controlling the heat transfer coefficient. The results of the present study can be used as a quantitative theoretical basis for removing the adverse effects induced by thermal deposition due to linear laser absorption in the crystal, such as depolarization or wave front distortion, and indicate the feasibility of adjusting the refractive index in the window area by changing the heat transfer

  2. Development and Application of Integrated Optical Sensors for Intense E-Field Measurement

    Directory of Open Access Journals (Sweden)

    Zhanqing Yu

    2012-08-01

    Full Text Available The measurement of intense E-fields is a fundamental need in various research areas. Integrated optical E-field sensors (IOESs have important advantages and are potentially suitable for intense E-field detection. This paper comprehensively reviews the development and applications of several types of IOESs over the last 30 years, including the Mach-Zehnder interferometer (MZI, coupler interferometer (CI and common path interferometer (CPI. The features of the different types of IOESs are compared, showing that the MZI has higher sensitivity, the CI has a controllable optical bias, and the CPI has better temperature stability. More specifically, the improvement work of applying IOESs to intense E-field measurement is illustrated. Finally, typical uses of IOESs in the measurement of intense E-fields are demonstrated, including application areas such as E-fields with different frequency ranges in high-voltage engineering, simulated nuclear electromagnetic pulse in high-power electromagnetic pulses, and ion-accelerating field in high-energy physics.

  3. Effect of nocturnal sound reduction on the incidence of delirium in intensive care unit patients: An interrupted time series analysis.

    Science.gov (United States)

    van de Pol, Ineke; van Iterson, Mat; Maaskant, Jolanda

    2017-08-01

    Delirium in critically-ill patients is a common multifactorial disorder that is associated with various negative outcomes. It is assumed that sleep disturbances can result in an increased risk of delirium. This study hypothesized that implementing a protocol that reduces overall nocturnal sound levels improves quality of sleep and reduces the incidence of delirium in Intensive Care Unit (ICU) patients. This interrupted time series study was performed in an adult mixed medical and surgical 24-bed ICU. A pre-intervention group of 211 patients was compared with a post-intervention group of 210 patients after implementation of a nocturnal sound-reduction protocol. Primary outcome measures were incidence of delirium, measured by the Intensive Care Delirium Screening Checklist (ICDSC) and quality of sleep, measured by the Richards-Campbell Sleep Questionnaire (RCSQ). Secondary outcome measures were use of sleep-inducing medication, delirium treatment medication, and patient-perceived nocturnal noise. A significant difference in slope in the percentage of delirium was observed between the pre- and post-intervention periods (-3.7% per time period, p=0.02). Quality of sleep was unaffected (0.3 per time period, p=0.85). The post-intervention group used significantly less sleep-inducing medication (psound-reduction protocol. However, reported sleep quality did not improve. Copyright © 2017. Published by Elsevier Ltd.

  4. The incidence rate and mortality of malignant brain tumors after 10 years of intensive cell phone use in Taiwan.

    Science.gov (United States)

    Hsu, Min-Huei; Syed-Abdul, Shabbir; Scholl, Jeremiah; Jian, Wen-Shan; Lee, Peisan; Iqbal, Usman; Li, Yu-Chuan

    2013-11-01

    The issue of whether cell phone usage can contribute toward the development of brain tumors has recently been reignited with the International Agency for Research on Cancer classifying radiofrequency electromagnetic fields as 'possibly' carcinogenic to humans in a WHO report. To our knowledge, this is the largest study reporting on the incidence and mortality of malignant brain tumors after long-term use of the cell phone by more than 23 million users. A population-based study was carried out the numbers of cell phone users were collected from the official statistics provided by the National Communication Commission. According to National Cancer Registry, there were 4 incidences and 4 deaths due to malignant neoplasms in Taiwan during the period 2000-2009. The 10 years of observational data show that the intensive user rate of cell phones has had no significant effect on the incidence rate or on the mortality of malignant brain tumors in Taiwan. In conclusion, we do not detect any correlation between the morbidity/mortality of malignant brain tumors and cell phone use in Taiwan. We thus urge international agencies to publish only confirmatory reports with more applicable conclusions in public. This will help spare the public from unnecessary worries.

  5. Worrisome trends in incidence and mortality of candidemia in intensive care units (Paris area, 2002-2010).

    Science.gov (United States)

    Lortholary, Olivier; Renaudat, Charlotte; Sitbon, Karine; Madec, Yoann; Denoeud-Ndam, Lise; Wolff, Michel; Fontanet, Arnaud; Bretagne, Stéphane; Dromer, Françoise

    2014-09-01

    To analyze trends in incidence and mortality of candidemia in intensive care units (ICUs) vs. non-ICU hospitalized patients and to determine risk factors for infection by specific species and for death. Active hospital-based surveillance program of incident episodes of candidemia due to common species in 24 tertiary care hospitals in the Paris area, France between October 2002 and September 2010. Among 2,507 adult cases included, 2,571 Candida isolates were collected and species were C. albicans (56 %), C. glabrata (18.6 %), C. parapsilosis (11.5 %), C. tropicalis (9.3 %), C. krusei (2.9 %), and C. kefyr (1.8 %). Candidemia occurred in ICU in 1,206 patients (48.1 %). When comparing ICU vs. non-ICU patients, the former had significantly more frequent surgery during the past 30 days, were more often preexposed to fluconazole and treated with echinocandin, and were less frequently infected with C. parapsilosis. Risk factors and age remained unchanged during the study period. A significant increased incidence in the overall population and ICU was found. The odds of being infected with a given species in ICU was influenced by risk factors and preexposure to fluconazole and caspofungin. Echinocandins initial therapy increased over time in ICU (4.6 % first year of study, to 48.5 % last year of study, p candidemia and death in ICU patients in the Paris area.

  6. Disposable diapers decrease the incidence of neonatal infections compared to cloth diapers in a level II neonatal intensive care unit.

    Science.gov (United States)

    Babu, M Chowdary; Tandur, Baswaraj; Sharma, Deepak; Murki, Srinivas

    2015-08-01

    To study whether disposable diapers decrease the incidence of neonatal infections compared with cloth diapers in a level II neonatal intensive care unit (NICU). All neonates admitted to the NICU and having duration of stay >48 h were enrolled. Those babies with signs and symptoms of infection were screened with septic screen and/or blood culture. The primary outcome of the study was incidence of probable sepsis. Of 253 babies enrolled in the study period, probable sepsis was present in 101 (39.9%) infants in the total study group and was higher in cloth diaper group as compared with disposable diaper group (p = 0.01). For an average NICU stay of 6 days, cloth diapers would cost Rs. 241 vs. Rs. 162 for disposable diaper for any infant. Usage of disposable diapers decrease the incidence of probable sepsis in babies admitted to NICU. It is also cost effective to use disposable diapers in the NICU. © The Author [2015]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Incidence of moisture-associated skin damage in an intensive care unit.

    Science.gov (United States)

    Valls-Matarín, J; Del Cotillo-Fuente, M; Ribal-Prior, R; Pujol-Vila, M; Sandalinas-Mulero, I

    To determine the incidence of moisture-associated skin damage (MASD) in the nappy area, identify predisposing factors and know the preventive measures and nursing records. Descriptive longitudinal study (June 2014-April 2015) in a general ICU. Patients whose stay >48hours and without skin lesions were included. The skin was assessed daily until the appearance of MASD, discharge or a maximum of 14 days. Demographics, stay, MASD type, incontinence, number and consistency of stools, obesity, Braden scale and prevention were recorded. 145 patients (66.2% male) were studied, median age was 69 (P 25 =56.5, P 75 =76) and median length of stay was five days (P 25 =3, P 75 =11.25), 29.9% were obese. Incontinence-associated dermatitis (IAD) was detected in 26.2% and intertriginous dermatitis (ITD) in 15.9%. MASD was recorded in 23.8%. The variables causing IAD to develop were faecal incontinence, number of stools, liquid stools, and stay. Those for ITD were obesity and score on the Braden scale. Multivariate analysis selected faecal incontinence (OR=5.4, CI95%: 1.1-26) and the number of stools (OR=1.1, CI95%:1.0-1.2) as independent variables for developing IAD and obesity (OR=2.8, CI95%:1.0-8.2) and Braden (OR=0.8, CI95%:0.7-1.0) for developing ITD. Prevention to 23.8% of obese and 42.9% of incontinent was performed. There is a high incidence in MASD. Faecal incontinence and higher number of stools are the risk factors for developing IAD. Obesity and a lower score on the Braden scale may affect susceptibility to ITD. Recording of MASD and its prevention in patients at risk is insufficient. Copyright © 2016 Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC). Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    International Nuclear Information System (INIS)

    Fiorella, D.; Helms, C.A.; Speer, K.P.

    2000-01-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  9. Increased T2 signal intensity in the distal clavicle: incidence and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiorella, D.; Helms, C.A. [Dept. of Radiology, Duke Univ., Durham, NC (United States); Speer, K.P. [Dept. of Orthopedic Surgery, Duke Univ., Durham, NC (United States)

    2000-12-01

    Objective. The objectives of the current study were (1) to quantify the incidence of increased T2 signal in the distal clavicle and (2) to assess the clinical significance of this finding in patients with chronic acromioclavicular (AC) joint pain.Design and patients. Eight patients (five male and three female, 15-41 years of age) with disabling shoulder pain localized to the AC joint and marked increased T2 signal in the distal clavicle are presented. These eight patients underwent MR examination over a 25 month period (August 1996 to September 1998). The dictated reports of all shoulder MR examinations conducted over this same time period were reviewed retrospectively for the presence of signal abnormality in the distal cla-vicle. Clinical data and, in five patients, findings at shoulder arthroscopy or open surgery, were correlated with the results of MR imaging. One patient underwent arthroscopy on both shoulders.Results. The selected eight patients each presented clinically with disabling shoulder pain localized to the AC joint. One patient is presented twice, as both shoulders were symptomatic (n=9). Plain film examination (9/9) failed to indicate a structural cause of shoulder pain in any of the patients. MR examination demonstrated abnormally increased T2 signal in the distal clavicle in all nine cases and no other cause for AC joint pain. Three patients responded to a course of conservative therapy. Six experienced refractory pain despite conservative therapy. Resection of the distal clavicle was performed in five of the six cases. All patients who underwent resection of the distal clavicle experienced complete resolution of AC joint pain. A retrospective review of the dictated reports for all shoulder MR imaging examinations performed at out institution over a 25 month period (August 1996 to September 1998; n=761) demonstrated a 12.5% incidence of abnormally increased T2 signal in the distal clav-icle.Conclusions. Increased T2 signal in the distal clavicle

  10. Optical gain for the interband optical transition in InAsP/InP quantum well wire in the influence of laser field intensity

    Energy Technology Data Exchange (ETDEWEB)

    Saravanan, S. [Dept.of Physics, GTN Arts College, Dindigul-624 005. India (India); Peter, A. John, E-mail: a.john.peter@gmail.com [P.G & Research Dept.of Physics, Government Arts College, Melur-625 106. Madurai. India (India)

    2016-05-23

    Intense high frequency laser field induced electronic and optical properties of heavy hole exciton in the InAs{sub 0.8}P{sub 0.2}/InP quantum wire is studied taking into account the geometrical confinement effect. Laser field related exciton binding energies and the optical band gap in the InAs{sub 0.8}P{sub 0.2}/InP quantum well wire are investigated. The optical gain, for the interband optical transition, as a function of photon energy, in the InAs{sub 0.8}P{sub 0.2}/InP quantum wire, is obtained in the presence of intense laser field. The compact density matrix method is employed to obtain the optical gain. The obtained optical gain in group III-V narrow quantum wire can be applied for achieving the preferred telecommunication wavelength.

  11. AN EVOLUTIONARY ALGORITHM FOR FAST INTENSITY BASED IMAGE MATCHING BETWEEN OPTICAL AND SAR SATELLITE IMAGERY

    Directory of Open Access Journals (Sweden)

    P. Fischer

    2018-04-01

    Full Text Available This paper presents a hybrid evolutionary algorithm for fast intensity based matching between satellite imagery from SAR and very high-resolution (VHR optical sensor systems. The precise and accurate co-registration of image time series and images of different sensors is a key task in multi-sensor image processing scenarios. The necessary preprocessing step of image matching and tie-point detection is divided into a search problem and a similarity measurement. Within this paper we evaluate the use of an evolutionary search strategy for establishing the spatial correspondence between satellite imagery of optical and radar sensors. The aim of the proposed algorithm is to decrease the computational costs during the search process by formulating the search as an optimization problem. Based upon the canonical evolutionary algorithm, the proposed algorithm is adapted for SAR/optical imagery intensity based matching. Extensions are drawn using techniques like hybridization (e.g. local search and others to lower the number of objective function calls and refine the result. The algorithm significantely decreases the computational costs whilst finding the optimal solution in a reliable way.

  12. Incidence of Candida species colonization in neonatal intensive care unit at Riyadh Hospital, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Mohammed S. Alhussaini

    2016-10-01

    Full Text Available Background: Candida species are important hospital-acquired pathogens in infants admitted to the neonatal intensive care unit (NICU. This study was performed in the NICU of Saudi Arabian Hospital, Riyadh region, KSA to analyze patterns of neonatal Candida colonization as well as to determine the potential risk factors.Methods: Weekly surveillance fungal cultures of anal area, oral cavity, umbilicus and ear canal of neonates were performed from birth until their discharge from the hospital. Colonization was analyzed for timing, site, species, birth weight and gestational age. Potential environmental reservoirs and hands of health care workers (HCWs were also cultured monthly for fungi. Antifungal susceptibility of the identified isolates was also determined.Results: One hundred subjects have been recruited in this study. The overall colonization rate was 51%. Early colonization was found in 27 (27% neonates whereas 24 (24% neonates were lately colonized during their stay in NICU. Colonization was more in preterm neonates than in full and post term. Perianal area and oral cavity were the most frequent colonized sites. C. albicans was the main spp. (58.8% isolated from the neonates followed by C. tropicalis (17.6%, C. glabrata (15.6%, and C. krusei (2%. Of the 51 isolated Candida spp., 68.6% were sensitive to fluconazole, 80% to itraconazole and 64.7% to ketoconazole, while only 33% were sensitive to amphotericin B.Conclusion: Candida has emerged as a common cause of infections in infants admitted to NICU, and C. albicans is the most commonly isolated candidal species. Neonatal infections caused by non- albicans species occur at a later age during their stay in NICU.

  13. System and method that suppresses intensity fluctuations for free space high-speed optical communication

    Science.gov (United States)

    Berman, Gennady P [Los Alamos, NM; Bishop, Alan R [Los Alamos, NM; Nguyen, Dinh C [Los Alamos, NM; Chernobrod, Boris M [Santa Fe, NM; Gorshkov, Vacheslav N [Kiev, UA

    2009-10-13

    A high-speed (Gbps), free space optical communication system is based on spectral encoding of radiation from a wide band light source, such as a laser. By using partially coherent laser beams in combination with a relatively slow photosensor, scintillations can be suppressed by orders of magnitude for distances of more than 10 km. To suppress the intensity fluctuations due to atmospheric turbulence, a source with partial transverse coherence in combination with slow response time photodetector is used. Information is encoded in the spectral domain of a wideband optical source by modulation of spectral amplitudes. A non-coherent light source with wide spectrum (an LED, for example) may be used for high-speed communication over short (less than about a mile) distances.

  14. Automatic Suppression of Intense Monochromatic Light in Electro-Optical Sensors

    Science.gov (United States)

    Ritt, Gunnar; Eberle, Bernd

    2012-01-01

    Electro-optical imaging sensors are widely distributed and used for many different tasks. Due to technical improvements, their pixel size has been steadily decreasing, resulting in a reduced saturation capacity. As a consequence, this progress makes them susceptible to intense point light sources. Developments in laser technology have led to very compact and powerful laser sources of any wavelength in the visible and near infrared spectral region, offered as laser pointers. The manifold of wavelengths makes it difficult to encounter sensor saturation over the complete operating waveband by conventional measures like absorption or interference filters. We present a concept for electro-optical sensors to suppress overexposure in the visible spectral region. The key element of the concept is a spatial light modulator in combination with wavelength multiplexing. This approach allows spectral filtering within a localized area in the field of view of the sensor. The system offers the possibility of automatic reduction of overexposure by monochromatic laser radiation. PMID:23202039

  15. Diarréia nosocomial em unidade de terapia intensiva: incidência e fatores de risco Nosocomial diarrhea in the intensive care unit: incidence and risk factors

    Directory of Open Access Journals (Sweden)

    Sérvulo Luiz Borges

    2008-06-01

    Full Text Available RACIONAL: Diarréia nosocomial parece ser comum em unidades de terapia intensiva, embora sua epidemiologia seja pouco documentada em nosso meio. OBJETIVO: Determinar a incidência e fatores de risco de diarréia entre pacientes adultos internados em unidade de terapia intensiva. MÉTODOS: Foram incluídos prospectivamente 457 pacientes no período entre outubro de 2005 e outubro de 2006. Dados demográficos, clínicos e bioquímicos, bem como aspecto e número de evacuações eram registrados diariamente até a saída do paciente do setor. RESULTADOS: Diarréia ocorreu em 135 (29,5% pacientes, durando em média 5,4 dias. O tempo do seu início em relação à internação foi de 17,8 dias e casos similares de diarréia no mesmo período foram registrados em 113 (83,7% pacientes. A mortalidade hospitalar foi maior nos pacientes com diarréia do que naqueles sem esta intercorrência. Na análise multivariada através de modelo de regressão logística, apenas o número de antibióticos (OR 1,65; IC 95% = 1,39-1,95 e o número de dias de antibioticoterapia (OR 1,16; IC 95% = 1,12-1,20 associaram-se estatisticamente com a ocorrência de diarréia. Cada dia de acréscimo a mais da antibioticoterapia aumentou em 16% o risco de diarréia (IC 12% a 20%, enquanto a adição de um antibiótico a mais ao esquema antimicrobiano aumentou as chances de ocorrência de diarréia em 65% (IC 39% a 95%. CONCLUSÃO: A incidência de diarréia nosocomial na unidade de terapia intensiva é elevada (29,5%. Os principais fatores de risco para sua ocorrência foram número de antibióticos prescritos e duração da antibioticoterapia. Além das precauções entéricas, a prescrição judiciosa e limitada de antimicrobianos, provavelmente reduzirá a ocorrência de diarréia neste setor.BACKGROUND: Nosocomial diarrhea seems to be common at intensive care units, although its epidemiology be poorly documented in Brazil. AIM: To determine the incidence and risk factors of

  16. Optical Frequency Optimization of a High Intensity Laser Power Beaming System Utilizing VMJ Photovoltaic Cells

    Science.gov (United States)

    Raible, Daniel E.; Dinca, Dragos; Nayfeh, Taysir H.

    2012-01-01

    An effective form of wireless power transmission (WPT) has been developed to enable extended mission durations, increased coverage and added capabilities for both space and terrestrial applications that may benefit from optically delivered electrical energy. The high intensity laser power beaming (HILPB) system enables long range optical 'refueling" of electric platforms such as micro unmanned aerial vehicles (MUAV), airships, robotic exploration missions and spacecraft platforms. To further advance the HILPB technology, the focus of this investigation is to determine the optimal laser wavelength to be used with the HILPB receiver, which utilizes vertical multi-junction (VMJ) photovoltaic cells. Frequency optimization of the laser system is necessary in order to maximize the conversion efficiency at continuous high intensities, and thus increase the delivered power density of the HILPB system. Initial spectral characterizations of the device performed at the NASA Glenn Research Center (GRC) indicate the approximate range of peak optical-to-electrical conversion efficiencies, but these data sets represent transient conditions under lower levels of illumination. Extending these results to high levels of steady state illumination, with attention given to the compatibility of available commercial off-the-shelf semiconductor laser sources and atmospheric transmission constraints is the primary focus of this paper. Experimental hardware results utilizing high power continuous wave (CW) semiconductor lasers at four different operational frequencies near the indicated band gap of the photovoltaic VMJ cells are presented and discussed. In addition, the highest receiver power density achieved to date is demonstrated using a single photovoltaic VMJ cell, which provided an exceptionally high electrical output of 13.6 W/sq cm at an optical-to-electrical conversion efficiency of 24 percent. These results are very promising and scalable, as a potential 1.0 sq m HILPB receiver of

  17. Localisation of intense sound produced by an optical pulsating discharge in the air

    Science.gov (United States)

    Grachev, G. N.; Miroshnichenko, I. B.; Smirnov, A. L.; Statsenko, P. A.; Tishchenko, V. N.; Berezutskii, A. G.

    2017-11-01

    It is shown that the localisation radius and the spectrum of intense sound produced by an optical pulsating discharge in the air depend on the power and repetition rate of the repetitively pulsed laser radiation, which is associated with a manifestation of the wave merging mechanism and sound absorption in the air. The experiment makes use of a CO2 laser with a power of ˜1.5 kW and a repetition rate of microsecond pulses of ˜50 kHz.

  18. Multiple time scales in modeling the incidence of infections acquired in intensive care units

    Directory of Open Access Journals (Sweden)

    Martin Wolkewitz

    2016-09-01

    Full Text Available Abstract Background When patients are admitted to an intensive care unit (ICU their risk of getting an infection will be highly depend on the length of stay at-risk in the ICU. In addition, risk of infection is likely to vary over calendar time as a result of fluctuations in the prevalence of the pathogen on the ward. Hence risk of infection is expected to depend on two time scales (time in ICU and calendar time as well as competing events (discharge or death and their spatial location. The purpose of this paper is to develop and apply appropriate statistical models for the risk of ICU-acquired infection accounting for multiple time scales, competing risks and the spatial clustering of the data. Methods A multi-center data base from a Spanish surveillance network was used to study the occurrence of an infection due to Methicillin-resistant Staphylococcus aureus (MRSA. The analysis included 84,843 patient admissions between January 2006 and December 2011 from 81 ICUs. Stratified Cox models were used to study multiple time scales while accounting for spatial clustering of the data (patients within ICUs and for death or discharge as competing events for MRSA infection. Results Both time scales, time in ICU and calendar time, are highly associated with the MRSA hazard rate and cumulative risk. When using only one basic time scale, the interpretation and magnitude of several patient-individual risk factors differed. Risk factors concerning the severity of illness were more pronounced when using only calendar time. These differences disappeared when using both time scales simultaneously. Conclusions The time-dependent dynamics of infections is complex and should be studied with models allowing for multiple time scales. For patient individual risk-factors we recommend stratified Cox regression models for competing events with ICU time as the basic time scale and calendar time as a covariate. The inclusion of calendar time and stratification by ICU

  19. Development of the theragnostic optical system for a high-intensity laser therapy (HILT).

    Science.gov (United States)

    Lee, Sangkwan; Kim, Tae-Hoon; Youn, Jong-In

    2014-09-01

    Recently, high-intensity laser therapy (HILT) has been introduced for muscle disorders, but its efficacy has not been confirmed due to the absence of quantitative assessments and treatment feedback data in real-time. In this clinical study, a theragnostic optical system comprised of a high-intensity laser and a non-invasive optical monitoring system was developed to assess spasticity. To avoid interference between the two different light sources, the therapeutic wavelength for HILT was selected at 808 nm, one of the isosbestic points. The monitoring system based on a near-infrared spectroscopy (NIRS) was utilized for measuring hemoglobin concentrations according to a modified Beer-Lambert's law. The transitory HILT effect was evaluated from patients experiencing spasticity after stroke. Our results showed the proportionate relationship between manual muscle testing grades and the HILT effect on hemiplegic patients. The developed system proved to be useful for the simultaneous assessment and treatment of spasticity, and it holds promise for real-time monitoring of hemoglobin concentrations during laser therapy.

  20. Adjustable Grazing Incidence X-ray Optics with 0.5 Arc Second Resolution

    Science.gov (United States)

    Reid, Paul

    We seek to develop adjustable grazing incidence optics for x-ray astronomy. The goal of this development is thin, lightweight mirrors with angular resolution of 0.5 arc seconds, comparable to the Chandra X-ray Observatory. The new mirror design consists of thin segments of a Wolter-I grazing incidence mirror, with piezo-electric material deposited directly on the back surface of the mirror. Depositing a pattern of independently addressable electrodes on top of the piezoelectric material produces an array of independent piezo cells. Energizing a particular cell introduces a localized deformation in the mirror without the need for a reaction structure. By applying the appropriate voltage to the piezo cells, it is possible to correct mirror figure errors that result from mirror fabrication, gravity release, mounting, and thermal effects. Because the thin mirrors segments are lightweight, they can be densely nested to produce collecting area thirty times that of Chandra, on an affordably priced mission. This Supporting Technology program is a follow-on to an existing APRA program. In the existing program we demonstrated the first successful deposition of piezoelectric material on thermally formed glass substrates. We showed that the localized deformations produced by the piezo cells match finite element predictions, and the piezo cell adjustment range meets requirements necessary to achieve the desired figure correction. We have also shown through simulation that representative mirror figure errors can be corrected via modeled influence functions to achieve 0.5 arc sec imaging performance. This provides a firm foundation on which to develop further the technology. We will continue to optimize the deposition of thin piezoelectric films onto thermally formed glass and electroplated metal mirror segments to improve yield and manufacturability. We will deposit piezoelectric material onto conical mirror segments and demonstrate figure correction in agreement with prediction

  1. Heavy-Tailed Fluctuations in the Spiking Output Intensity of Semiconductor Lasers with Optical Feedback.

    Directory of Open Access Journals (Sweden)

    Boon Leong Lan

    Full Text Available Although heavy-tailed fluctuations are ubiquitous in complex systems, a good understanding of the mechanisms that generate them is still lacking. Optical complex systems are ideal candidates for investigating heavy-tailed fluctuations, as they allow recording large datasets under controllable experimental conditions. A dynamical regime that has attracted a lot of attention over the years is the so-called low-frequency fluctuations (LFFs of semiconductor lasers with optical feedback. In this regime, the laser output intensity is characterized by abrupt and apparently random dropouts. The statistical analysis of the inter-dropout-intervals (IDIs has provided many useful insights into the underlying dynamics. However, the presence of large temporal fluctuations in the IDI sequence has not yet been investigated. Here, by applying fluctuation analysis we show that the experimental distribution of IDI fluctuations is heavy-tailed, and specifically, is well-modeled by a non-Gaussian stable distribution. We find a good qualitative agreement with simulations of the Lang-Kobayashi model. Moreover, we uncover a transition from a less-heavy-tailed state at low pump current to a more-heavy-tailed state at higher pump current. Our results indicate that fluctuation analysis can be a useful tool for investigating the output signals of complex optical systems; it can be used for detecting underlying regime shifts, for model validation and parameter estimation.

  2. Type IIA photosensitivity and formation of pores in optical fibers under intense ultraviolet irradiation

    International Nuclear Information System (INIS)

    Kukushkin, S. A.; Shlyagin, M. G.; Swart, P. L.; Chtcherbakov, A. A.; Osipov, A. V.

    2007-01-01

    Formation of the type IIA Bragg gratings in germanosilicate optical fibers is studied. We report the observation of such a type of gratings in the standard single-mode fiber (Corning SMF-28) under different experimental conditions. A mechanism for the type IIA photosensitivity in optical fibers is proposed which is based on nucleation and evolution of pores from vacancy-type defects in fiber areas where a high level of mechanical stress is induced under intense ultraviolet (UV) light. Evolution of fiber core temperature under influence of a single 20 ns light pulse from a KrF excimer laser was measured and compared with theoretical calculations. It was shown that transient thermoinduced stress in the fiber core can achieve a level sufficient for effective nucleation of pores. A theory describing formation of pores in optical fibers has been developed and was used to estimate the pore nucleation rate, concentration, and other parameters of pore evolution for different levels of UV fluence and fiber core stress

  3. Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry

    Science.gov (United States)

    Dekker, Kurtis H.; Hazarika, Rubin; Silveira, Matheus A.; Jordan, Kevin J.

    2018-03-01

    Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large (⩾10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5–10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%–20% of the camera sensor’s range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes (∼15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.

  4. Wavelength reused bidirectional transmission of adaptively modulated optical OFDM signals in WDM-PONs incorporating SOA and RSOA intensity modulators.

    Science.gov (United States)

    Wei, J L; Hugues-Salas, E; Giddings, R P; Jin, X Q; Zheng, X; Mansoor, S; Tang, J M

    2010-05-10

    Detailed numerical investigations are undertaken of wavelength reused bidirectional transmission of adaptively modulated optical OFDM (AMOOFDM) signals over a single SMF in a colorless WDM-PON incorporating a semiconductor optical amplifier (SOA) intensity modulator and a reflective SOA (RSOA) intensity modulator in the optical line termination and optical network unit, respectively. A comprehensive theoretical model describing the performance of such network scenarios is, for the first time, developed, taking into account dynamic optical characteristics of SOA and RSOA intensity modulators as well as the effects of Rayleigh backscattering (RB) and residual downstream signal-induced crosstalk. The developed model is rigorously verified experimentally in RSOA-based real-time end-to-end OOFDM systems at 7.5 Gb/s. It is shown that the RB noise and crosstalk effects are dominant factors limiting the maximum achievable downstream and upstream transmission performance. Under optimum SOA and RSOA operating conditions as well as practical downstream and upstream optical launch powers, 10 Gb/s downstream and 6 Gb/s upstream over 40 km SMF transmissions of conventional double sideband AMOOFDM signals are feasible without utilizing in-line optical amplification and chromatic dispersion compensation. In particular, the aforementioned transmission performance can be improved to 23 Gb/s downstream and 8 Gb/s upstream over 40 km SMFs when single sideband subcarrier modulation is adopted in the downstream systems. (c) 2010 Optical Society of America.

  5. Transrectal high-intensity focused ultrasound (HIFU) treatment of localized prostate cancer: Review of technical incidents and morbidity after 5 years of use

    OpenAIRE

    RIPERT, Thomas; AZEMAR, Marie Dominique; MENARD, Johann; BAYOUD, Younes; MESSAOUDI, Rabah; DUVAL, François; STAERMAN, Frédéric

    2010-01-01

    Abstract OBJECTIVE To report on technical incidents, and early and late complications, occurring on high-intensity focused ultrasound (HIFU) treatment of patients with localized prostate cancer. PATIENTS AND METHODS We performed a retrospective review of patients who were treated by Ablatherm? in our centre. We recorded all technical incidents, treatment discontinuations, and early (< 1 month) and late complications. RESULTS A total of 74 HIFU procedures were perfor...

  6. Incidence of severe sepsis and septic shock in German intensive care units: the prospective, multicentre INSEP study.

    Science.gov (United States)

    2016-12-01

    To estimate the incidence density, point prevalence and outcome of severe sepsis and septic shock in German intensive care units (ICUs). In a prospective, multicentre, longitudinal observational study, all patients already on the ICU at 0:00 on 4 November 2013 and all patients admitted to a participating ICU between 0:00 on 4 November 2013 and 2359 hours on 1 December 2013 were included. The patients were followed up for the occurrence of severe sepsis or septic shock (SEPSIS-1 definitions) during their ICU stay. A total of 11,883 patients from 133 ICUs at 95 German hospitals were included in the study, of whom 1503 (12.6 %) were diagnosed with severe sepsis or septic shock. In 860 cases (57.2 %) the infections were of nosocomial origin. The point prevalence was 17.9 % (95 % CI 16.3-19.7).The calculated incidence rate of severe sepsis or septic shock was 11.64 (95 % CI 10.51-12.86) per 1000 ICU days. ICU mortality in patients with severe sepsis/septic shock was 34.3 %, compared with 6 % in those without sepsis. Total hospital mortality of patients with severe sepsis or septic shock was 40.4 %. Classification of the septic shock patients using the new SEPSIS-3 definitions showed higher ICU and hospital mortality (44.3 and 50.9 %). Severe sepsis and septic shock continue to be a frequent syndrome associated with high hospital mortality. Nosocomial infections play a major role in the development of sepsis. This study presents a pragmatic, affordable and feasible method for the surveillance of sepsis epidemiology. Implementation of the new SEPSIS-3 definitions may have a major effect on future epidemiological data.

  7. Incidence and Outcomes of Central Nervous System Hemophagocytic Lymphohistiocytosis Relapse after Reduced-Intensity Conditioning Hematopoietic Stem Cell Transplantation.

    Science.gov (United States)

    Lounder, Dana T; Khandelwal, Pooja; Chandra, Sharat; Jordan, Michael B; Kumar, Ashish R; Grimley, Michael S; Davies, Stella M; Bleesing, Jack J; Marsh, Rebecca A

    2017-05-01

    Hemophagocytic lymphohistiocytosis (HLH) is an immune regulatory disorder that commonly presents with central nervous system (CNS) involvement. The only cure for genetic HLH is hematopoietic stem cell transplantation (HSCT), typically treated with reduced-intensity conditioning (RIC) regimens. We sought to estimate the incidence of CNS relapse after RIC HSCT, determine risk factors, and evaluate outcomes. We performed a retrospective chart review of 94 consecutive children and young adults with primary HLH who received RIC HSCT. CNS relapse within 1 year after transplantation was diagnosed by review of clinical symptoms, cerebral spinal fluid (CSF), and radiologic findings. Four (4.25%) patients developed symptoms of possible CNS HLH after HSCT and 3 patients were diagnosed. Eight patients underwent screening lumbar puncture because of history of active CNS disease at the onset of the conditioning regimen and 4 had evidence of continued disease. The overall incidence of CNS relapse and continued CNS disease after RIC HSCT was 8%. All patients with CNS disease after HSCT responded to CNS-directed therapy. Whole blood donor chimerism at the time of CNS relapse was low at 1% to 34%, but it remained high at 88% to 100% for patients with continued CNS disease. Overall survival for patients with CNS relapse was 50%, compared with 75% for patients without CNS disease (P = .079). Our data suggest that a low level of donor chimerism or active CNS disease at the time of transplantation increase the risk of CNS HLH after HSCT. Surveillance CSF evaluation after allogeneic RIC HSCT should be considered in patients with risk factors and CNS-directed treatment should be initiated if appropriate. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Incidence and Risk Factors for Intensive Care Unit–related Post-traumatic Stress Disorder in Veterans and Civilians

    Science.gov (United States)

    Jackson, James C.; Morandi, Alessandro; Girard, Timothy D.; Hughes, Christopher G.; Thompson, Jennifer L.; Kiehl, Amy L.; Elstad, Mark R.; Wasserstein, Mitzi L.; Goodman, Richard B.; Beckham, Jean C.; Chandrasekhar, Rameela; Dittus, Robert S.; Ely, E. Wesley; Pandharipande, Pratik P.

    2016-01-01

    Rationale: The incidence and risk factors of post-traumatic stress disorder (PTSD) related to the intensive care unit (ICU) experience have not been reported in a mixed veteran and civilian cohort. Objectives: To describe the incidence and risk factors for ICU-related PTSD in veterans and civilians. Methods: This is a prospective, observational, multicenter cohort enrolling adult survivors of critical illness after respiratory failure and/or shock from three Veterans Affairs and one civilian hospital. After classifying those with/without preexisting PTSD (i.e., PTSD before hospitalization), we then assessed all subjects for ICU-related PTSD at 3 and 12 months post hospitalization. Measurements and Main Results: Of 255 survivors, 181 and 160 subjects were assessed for ICU-related PTSD at 3- and 12-month follow-up, respectively. A high probability of ICU-related PTSD was found in up to 10% of patients at either follow-up time point, whether assessed by PTSD Checklist Event-Specific Version (score ≥ 50) or item mapping using the Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV). In the multivariable regression, preexisting PTSD was independently associated with ICU-related PTSD at both 3 and 12 months (P < 0.001), as was preexisting depression (P < 0.03), but veteran status was not a consistent independent risk factor for ICU-related PTSD (3-month P = 0.01, 12-month P = 0.48). Conclusions: This study found around 1 in 10 ICU survivors experienced ICU-related PTSD (i.e., PTSD anchored to their critical illness) in the year after hospitalization. Preexisting PTSD and depression were strongly associated with ICU-related PTSD. PMID:26735627

  9. Computer-Controlled Cylindrical Polishing Process for Development of Grazing Incidence Optics for Hard X-Ray Region

    Science.gov (United States)

    Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.

  10. Optical intensity modulation direct detection versus heterodyne detection: A high-SNR capacity comparison

    KAUST Repository

    Chaaban, Anas

    2016-09-15

    An optical wireless communications system which employs either intensity-modulation and direct-detection (IM-DD) or heterodyne detection (HD) is considered. IM-DD has lower complexity and cost than HD, but on the other hand, has lower capacity. It is therefore interesting to investigate the capacity gap between the two systems. The main focus of this paper is to investigate this gap at high SNR. Bounds on this gap are established for two cases: between IM-DD and HD, and between IM-DD and an HD-PAM which is an HD system employing pulse-amplitude modulation (PAM). While the gap between IM-DD and HD increases as the signal-to-noise ratio (SNR) increases, the gap between IM-DD and an HD-PAM is upper bounded by a constant at high SNR. © 2015 IEEE.

  11. Poisson-Spot Intensity Reduction with a Partially-Transparent Petal-Shaped Optical Mask

    Science.gov (United States)

    Shiri, Shahram; Wasylkiwskyj, Wasyl

    2013-01-01

    The presence of Poisson's spot, also known as the spot of Arago, formed along the optical axis in the geometrical shadow behind an obstruction, has been known since the 18th century. The presence of this spot can best be described as the consequence of constructive interference of light waves diffracted on the edge of the obstruction where its central position can··be determined by the symmetry of the object More recently, the elimination of this spot has received attention in the fields of particle physics, high-energy lasers, astronomy and lithography. In this paper, we introduce a novel, partially transparent petaled mask shape that suppresses the bright spot by up to 10 orders of magnitude in intensity, with powerful applications to many of the above fields. The optimization technique formulated in this design can identify mask shapes having partial transparency only near the petal tips.

  12. Results after implementation of a protocol on the incidence of urinary tract infection in an intensive care unit 1

    Science.gov (United States)

    Miranda, Anna Letícia; de Oliveira, Ana Lúcia Lyrio; Nacer, Daiana Terra; Aguiar, Cynthia Adalgisa Mesojedovas

    2016-01-01

    ABSTRACT Objective: to compare the results of urinary tract infection incidence, by means of the rate of indwelling urethral catheter use, and to identify microorganisms in urine cultures and surveillance cultures before and after the implementation of a clinical protocol for intensive care unit patients . Method: urinary tract infection is defined as a positive urine culture > 105 CFU/mL, notified by the hospital infection control service, six months before and after the implementation of the protocol. The sample consisted of 47 patients, 28 reported before and 19 after implementation. The protocol established in the institution is based on the Ministry of Health manual to prevent healthcare-related infections; the goal is patient safety and improving the quality of health services. Results: a negative linear correlation was observed between the later months of implementation and the reduction of reported cases of urinary tract infection, using the Spearman rank order coefficient (p = 0.045), and a reduction in the number of urine culture microorganisms (p = 0.026) using the Fisher exact test. Conclusion: educational interventions with implementation protocols in health institutions favor the standardization of maintenance of the invasive devices, which may reduce colonization and subsequent infections. PMID:27627125

  13. Effect of angular intensity distribution of radiation on a conoscopic pattern of crystal

    Science.gov (United States)

    Pikoul, O. Y.; Kovalenko, L. L.

    2016-08-01

    Angular intensity distribution of radiation in incident converging beam effects on the appearance of a conoscopic pattern of optical crystal. The peculiarities of a «Maltese cross» formation in the conoscopic patterns of optical crystals are considered.

  14. Layered ACO-OFDM for intensity-modulated direct-detection optical wireless transmission.

    Science.gov (United States)

    Wang, Qi; Qian, Chen; Guo, Xuhan; Wang, Zhaocheng; Cunningham, David G; White, Ian H

    2015-05-04

    Layered asymmetrically clipped optical orthogonal frequency division multiplexing (ACO-OFDM) with high spectral efficiency is proposed in this paper for optical wireless transmission employing intensity modulation with direct detection. In contrast to the conventional ACO-OFDM, which only utilizes odd subcarriers for modulation, leading to an obvious spectral efficiency loss, in layered ACO-OFDM, the subcarriers are divided into different layers and modulated by different kinds of ACO-OFDM, which are combined for simultaneous transmission. In this way, more subcarriers are used for data transmission and the spectral efficiency is improved. An iterative receiver is also proposed for layered ACO-OFDM, where the negative clipping distortion of each layer is subtracted once it is detected so that the signals from different layers can be recovered. Theoretical analysis shows that the proposed scheme can improve the spectral efficiency by up to 2 times compared with conventional ACO-OFDM approaches with the same modulation order. Meanwhile, simulation results confirm a considerable signal-to-noise ratio gain over ACO-OFDM at the same spectral efficiency.

  15. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    Science.gov (United States)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  16. Diversity-optimal power loading for intensity modulated MIMO optical wireless communications.

    Science.gov (United States)

    Zhang, Yan-Yu; Yu, Hong-Yi; Zhang, Jian-Kang; Zhu, Yi-Jun

    2016-04-18

    In this paper, we consider the design of space code for an intensity modulated direct detection multi-input-multi-output optical wireless communication (IM/DD MIMO-OWC) system, in which channel coefficients are independent and non-identically log-normal distributed, with variances and means known at the transmitter and channel state information available at the receiver. Utilizing the existing space code design criterion for IM/DD MIMO-OWC with a maximum likelihood (ML) detector, we design a diversity-optimal space code (DOSC) that maximizes both large-scale diversity and small-scale diversity gains and prove that the spatial repetition code (RC) with a diversity-optimized power allocation is diversity-optimal among all the high dimensional nonnegative space code schemes under a commonly used optical power constraint. In addition, we show that one of significant advantages of the DOSC is to allow low-complexity ML detection. Simulation results indicate that in high signal-to-noise ratio (SNR) regimes, our proposed DOSC significantly outperforms RC, which is the best space code currently available for such system.

  17. Quantum key distribution with an efficient countermeasure against correlated intensity fluctuations in optical pulses

    Science.gov (United States)

    Yoshino, Ken-ichiro; Fujiwara, Mikio; Nakata, Kensuke; Sumiya, Tatsuya; Sasaki, Toshihiko; Takeoka, Masahiro; Sasaki, Masahide; Tajima, Akio; Koashi, Masato; Tomita, Akihisa

    2018-03-01

    Quantum key distribution (QKD) allows two distant parties to share secret keys with the proven security even in the presence of an eavesdropper with unbounded computational power. Recently, GHz-clock decoy QKD systems have been realized by employing ultrafast optical communication devices. However, security loopholes of high-speed systems have not been fully explored yet. Here we point out a security loophole at the transmitter of the GHz-clock QKD, which is a common problem in high-speed QKD systems using practical band-width limited devices. We experimentally observe the inter-pulse intensity correlation and modulation pattern-dependent intensity deviation in a practical high-speed QKD system. Such correlation violates the assumption of most security theories. We also provide its countermeasure which does not require significant changes of hardware and can generate keys secure over 100 km fiber transmission. Our countermeasure is simple, effective and applicable to wide range of high-speed QKD systems, and thus paves the way to realize ultrafast and security-certified commercial QKD systems.

  18. On the Capacity Region of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2015-08-11

    The capacity of the intensity-modulation direct-detection free-space optical broadcast channel (OBC) is investigated. The Gaussian model with input-independent Gaussian noise is used, with both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans\\' approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian distributions or discrete distributions. While the discrete input distribution achieves higher rates than the truncated-Gaussian distribution, the latter allows expressing the achievable rate region in a closed form. At high signal-to-noise ratio (SNR), it is shown that the truncated-Gaussian distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows large. It also achieves the capacity region within a constant gap, which depends on the number of users. At low SNR, it is shown that on-off keying with time-division multiple-access (TDMA) is optimal, as it achieves any point on the boundary of the developed outer bound. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves a fairly good performance in terms of symmetric rate.

  19. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2016-01-12

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  20. Intense transient electric field sensor based on the electro-optic effect of LiNbO3

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2015-10-01

    Full Text Available Intense transient electric field measurements are widely applied in various research areas. An optical intense E-field sensor for time-domain measurements, based on the electro-optic effect of lithium niobate, has been studied in detail. Principles and key issues in the design of the sensor are presented. The sensor is insulated, small in size (65 mm × 15 mm × 15 mm, and suitable for high-intensity (<801 kV/m electric field measurements over a wide frequency band (10 Hz–10 MHz. The input/output characteristics of the sensor were obtained and the sensor calibrated. Finally, an application using this sensor in testing laboratory lightning impulses and in measuring transient electric fields during switch-on of a disconnector confirmed that the sensor is expected to find widespread use in transient intense electric field measurement applications.

  1. Incidence and Severity of Prescribing Errors in Parenteral Nutrition for Pediatric Inpatients at a Neonatal and Pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Theresa Hermanspann

    2017-06-01

    Full Text Available ObjectivesPediatric inpatients are particularly vulnerable to medication errors (MEs, especially in highly individualized preparations like parenteral nutrition (PN. Aside from prescribing via a computerized physician order entry system (CPOE, we evaluated the effect of cross-checking by a clinical pharmacist to prevent harm from PN order errors in a neonatal and pediatric intensive care unit (NICU/PICU.MethodsThe incidence of prescribing errors in PN in a tertiary level NICU/PICU was surveyed prospectively between March 2012 and July 2013 (n = 3,012 orders. A pharmacist cross-checked all PN orders prior to preparation. Errors were assigned to seven different error-type categories. Three independent experts from different academic tertiary level NICUs judged the severity of each error according to the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP Index (categories A–I.ResultsThe error rate was 3.9% for all 3,012 orders (118 prescribing errors in 111 orders. 77 (6.0%, 1,277 orders errors occurred in the category concentration range, all concerning a relative overdose of calcium gluconate for peripheral infusion. The majority of all events (60% were assigned to categories C and D (without major harmful consequences while 28% could not be assigned due to missing majority decision. Potential harmful consequences requiring interventions (category E could have occurred in 12% of assessments.ConclusionNext to systematic application of clinical guidelines and prescribing via CPOE, order review by a clinical pharmacist is still required to effectively reduce MEs and thus to prevent minor and major adverse drug events with the aim to enhance medication safety.

  2. Optical diffraction tomography microscopy with transport of intensity equation using a light-emitting diode array

    Science.gov (United States)

    Li, Jiaji; Chen, Qian; Zhang, Jialin; Zhang, Zhao; Zhang, Yan; Zuo, Chao

    2017-08-01

    Optical diffraction tomography (ODT) is an effective label-free technique for quantitatively refractive index imaging, which enables long-term monitoring of the internal three-dimensional (3D) structures and molecular composition of biological cells with minimal perturbation. However, existing optical tomographic methods generally rely on interferometric configuration for phase measurement and sophisticated mechanical systems for sample rotation or beam scanning. Thereby, the measurement is suspect to phase error coming from the coherent speckle, environmental vibrations, and mechanical error during data acquisition process. To overcome these limitations, we present a new ODT technique based on non-interferometric phase retrieval and programmable illumination emitting from a light-emitting diode (LED) array. The experimental system is built based on a traditional bright field microscope, with the light source replaced by a programmable LED array, which provides angle-variable quasi-monochromatic illumination with an angular coverage of ±37 degrees in both x and y directions (corresponding to an illumination numerical aperture of ∼0.6). Transport of intensity equation (TIE) is utilized to recover the phase at different illumination angles, and the refractive index distribution is reconstructed based on the ODT framework under first Rytov approximation. The missing-cone problem in ODT is addressed by using the iterative non-negative constraint algorithm, and the misalignment of the LED array is further numerically corrected to improve the accuracy of refractive index quantification. Experiments on polystyrene beads and thick biological specimens show that the proposed approach allows accurate refractive index reconstruction while greatly reduced the system complexity and environmental sensitivity compared to conventional interferometric ODT approaches.

  3. Incidence and Outcomes of Optical Zone Enlargement and Recentration After Previous Myopic LASIK by Topography-Guided Custom Ablation.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Carp, Glenn I; Stuart, Alastair J; Rowe, Elizabeth L; Nesbit, Andrew; Moore, Tara

    2018-02-01

    To report the incidence, visual and refractive outcomes, optical zone enlargement, and recentration using topography-guided CRS-Master TOSCA II software with the MEL 80 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) after primary myopic laser refractive surgery. Retrospective analysis of 73 eyes (40 patients) with complaints of night vision disturbances due to either a decentration or small optical zone following a primary myopic laser refractive surgery procedure using the MEL 80 laser. Multiple ATLAS topography scans were imported into the CRS-Master software for topography-guided ablation planning. The topography-guided re-treatment procedure was performed as either a LASIK flap lift, a new LASIK flap, a side cut only, or photorefractive keratectomy. Axial curvature maps were analyzed using a fixed grid and set of concentric circles superimposed to measure the topographic optical zone diameter and centration. Follow-up was 12 months. The incidence of use in the population of myopic treatments during the study period was 0.79% (73 of 9,249). The optical zone diameter was increased by 11% from a mean of 5.65 to 6.32 mm, with a maximum change of 2 mm in one case. Topographic decentration was reduced by 64% from a mean of 0.58 to 0.21 mm. There was a 44% reduction in spherical aberration, 53% reduction in coma, and 39% reduction in total higher order aberrations. A subjective improvement in night vision symptoms was reported by 93%. Regarding efficacy, 82% of eyes reached 20/20 and 100% reached 20/32 (preoperative CDVA was 20/20 or better in 90%). Regarding safety, no eyes lost two lines of CDVA and 27% gained one line. Regarding predictability, 71% of re-treatments were within ±0.50 diopters. Topography-guided ablation was effective in enlarging the optical zone, recentering the optical zone, and reducing higher order aberrations. Topography-guided custom ablation appears to be an effective method for re-treatment procedures of symptomatic patients after

  4. The impact of relative intensity noise on the signal in multiple reference optical coherence tomography

    Science.gov (United States)

    Neuhaus, Kai; Subhash, Hrebesh; Alexandrov, Sergey; Dsouza, Roshan; Hogan, Josh; Wilson, Carol; Leahy, Martin; Slepneva, Svetlana; Huyet, Guillaume

    2016-03-01

    Multiple reference optical coherence tomography (MR-OCT) applies a unique low-cost solution to enhance the scanning depth of standard time domain OCT by inserting an partial mirror into the reference arm of the interferometric system. This novel approach achieves multiple reflections for different layers and depths of an sample with minimal effort of engineering and provides an excellent platform for low-cost OCT systems based on well understood production methods for micro-mechanical systems such as CD/DVD pick-up systems. The direct integration of a superluminescent light-emitting diode (SLED) is a preferable solution to reduce the form- factor of an MR-OCT system. Such direct integration exposes the light source to environmental conditions that can increase fluctuations in heat dissipation and vibrations and affect the noise characteristics of the output spectrum. This work describes the impact of relative intensity noise (RIN) on the quality of the interference signal of MR-OCT related to a variety of environmental conditions, such as temperature.

  5. Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Erik A. [Los Alamos National Laboratory

    2012-06-07

    Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity

  6. Dependence of optical properties of monoclinic MnWO{sub 4} on the electric field of incident light

    Energy Technology Data Exchange (ETDEWEB)

    Cai Lugang [School of Physics and Nuclear Energy Engineering, Key Laboratory of Micro-nano Measurement-Manipulation and Physics (Ministry of Education), Beihang University, Beijing 100191 (China); Liu Famin, E-mail: fmliu@buaa.edu.cn [School of Physics and Nuclear Energy Engineering, Key Laboratory of Micro-nano Measurement-Manipulation and Physics (Ministry of Education), Beihang University, Beijing 100191 (China); Zhang Dian; Zhong Wenwu [School of Physics and Nuclear Energy Engineering, Key Laboratory of Micro-nano Measurement-Manipulation and Physics (Ministry of Education), Beihang University, Beijing 100191 (China)

    2012-09-01

    Considering the electric field of incident light along four particular directions [100], [110], [011], and [010], the optical properties of monoclinic MnWO{sub 4} were investigated by the first-principle methods. The calculated electronic structures show that the O 2p states and Mn 3d states dominate the top of the valence bands, while the W 5d and Mn 3d states play a key role in the bottom of the conduction bands. The dielectric function and other optical properties, including absorption coefficient, reflectivity spectra, and energy-loss spectra, were calculated and analyzed. The results predicted the maximum static dielectric function when the electric field of incident light was along the [100] direction; meanwhile the absorption edge was calculated to be consistent with the energy band gap and the values and positions of peaks in absorption coefficient are related with the electric field of light. Otherwise, it is found that the appearance of peaks in the energy-loss spectra is also dependent on the electric field and simultaneously corresponds to the edge of absorption spectra and the peaks' position of reflectivity spectra.

  7. Investigation on the influence of intensity scintillation and beam wander in space optical uplink DWDM communication system

    Science.gov (United States)

    Li, Mi; Chen, Mengji; Zhang, Xuping; Cong, Hengji; Song, Yuejiang; Lu, Yuangang

    2016-04-01

    Dense wavelength division multiplexing (DWDM) has been widely applied in ground optical communication. However, the technology of DWDM is still not mature enough in the space optical communication system. In order to further advance the use of DWDM into space optical communication, the probability density function (PDF) and the bit-error rate (BER) performance of DWDM is investigated in uplink communications under the influence of atmospheric turbulence, consisting of intensity scintillation and beam wander caused by atmospheric turbulence. Numerical results show that the atmospheric turbulence has a great impact on BER and PDF, and wavelength, divergence angel, and other relevant parameters should be carefully considered in this DWDM system. This work can be conducive for improving DWDM design of space optical uplink communication systems.

  8. A new optical method for measuring surface temperature at large incident probe angles

    Science.gov (United States)

    Lee, A. S.; Norris, P. M.

    1997-02-01

    A novel thermoreflectance technique has been developed for noncontact temperature measurements using laser light incident at large angles on solid materials and devices. The method involves measuring the differential reflectance from a polarization modulated laser beam. The polarization differential reflectance technique is demonstrated on single-crystal Si wafers and on a polycrystalline carbon thin film over a temperature range of 20-60 °C. The method is shown to be an extremely sensitive temperature probe for near grazing angle measurements, which could be useful for monitoring the surface temperature of closely stacked silicon wafers used in batch processing in the microelectronics industry.

  9. Mounting for Fabrication, Metrology, and Assembly of Full Shell Grazing Incidence Optics

    Science.gov (United States)

    Roche, Jacqueline M.; Gubarev, Mikhail V.; O'Dell, Stephen L.; Kolodziejczak, Jeffery; Weisskopf, Martin C.; Ramsey, Brian D.; Elsner, Ronald F.

    2014-01-01

    Future x-ray telescopes will likely require lightweight mirrors to attain the large collecting areas needed to accomplish the science objectives. Understanding and demonstrating processes now is critical to achieving sub-arcsecond performance in the future. Consequently, designs not only of the mirrors but of fixtures for supporting them during fabrication, metrology, handling, assembly, and testing must be adequately modeled and verified. To this end, MSFC is using finite-element modeling to study the effects of mounting on full-shell grazing-incidence mirrors, during all processes leading to flight mirror assemblies. Here we report initial results of this study.

  10. AXAF optical technology analysis. [effects of alignment figure errors on the performance of grazing incidence telescopes

    Science.gov (United States)

    Korsch, D.

    1979-01-01

    A grazing incidence telescope with six nested subsystems is investigated through the effects of misalignment and surface deformations on it's image quality. The axial rms-spot size serves as measure for the image quality. The surface deformations are simulated by ellipsoidal and sinusoidal deviation elements. Each type of defect is analyzed in the single two-element system. The full nested system is then analyzed in the presence of all possible defects on all twelve elements, whereby the magnitude of the defects is randomized within a given upper limit.

  11. Results after implementation of a protocol on the incidence of urinary tract infection in an intensive care unit.

    Science.gov (United States)

    Miranda, Anna Letícia; Oliveira, Ana Lúcia Lyrio de; Nacer, Daiana Terra; Aguiar, Cynthia Adalgisa Mesojedovas

    2016-09-09

    to compare the results of urinary tract infection incidence, by means of the rate of indwelling urethral catheter use, and to identify microorganisms in urine cultures and surveillance cultures before and after the implementation of a clinical protocol for intensive care unit patients . urinary tract infection is defined as a positive urine culture > 105 CFU/mL, notified by the hospital infection control service, six months before and after the implementation of the protocol. The sample consisted of 47 patients, 28 reported before and 19 after implementation. The protocol established in the institution is based on the Ministry of Health manual to prevent healthcare-related infections; the goal is patient safety and improving the quality of health services. a negative linear correlation was observed between the later months of implementation and the reduction of reported cases of urinary tract infection, using the Spearman rank order coefficient (p = 0.045), and a reduction in the number of urine culture microorganisms (p = 0.026) using the Fisher exact test. educational interventions with implementation protocols in health institutions favor the standardization of maintenance of the invasive devices, which may reduce colonization and subsequent infections. comparar os resultados da incidência de infecção do trato urinário, por meio da taxa de utilização do cateter vesical de demora e identificar os micro-organismos na urocultura e cultura de vigilância antes e após a implementação de um protocolo assistencial em pacientes internados em unidade de terapia intensiva. definiu-se infecção do trato urinário pacientes com urocultura positiva >105 UFC/mL, notificados pelo Serviço de Controle de Infecção Hospitalar, seis meses antes e após a implementação do protocolo. A amostra foi constituída por 47 pacientes, sendo 28 notificados antes e 19 após. O protocolo, criado na instituição, é baseado no manual do Ministério da Saúde na prevenção de

  12. Analysis and compensation for the effect of the catheter position on image intensities in intravascular optical coherence tomography

    DEFF Research Database (Denmark)

    Liu, Shengnan; Eggermont, Jeroen; Wolterbeek, Ron

    2016-01-01

    Intravascular optical coherence tomography (IVOCT) is an imaging technique that is used to analyze the underlying cause of cardiovascular disease. Because a catheter is used during imaging, the intensities can be affected by the catheter position. This work aims to analyze the effect...... of the catheter position on IVOCT image intensities and to propose a compensation method to minimize this effect in order to improve the visualization and the automatic analysis of IVOCT images. The effect of catheter position is modeled with respect to the distance between the catheter and the arterial wall...

  13. Pump-to-Signal Intensity Modulation Transfer in Saturated- Gain Fiber Optical Parametric Amplifiers

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke; Rottwitt, Karsten

    2011-01-01

    The pump-to-signal intensity modulation transfer in saturated degenerate FOPAs is numerically investigated over the whole gain bandwidth. The intensity modulation transfer decreases and the OSNR improves when the amplifier operates in the saturation regime....

  14. Amplification of the Signal Intensity of Fluorescence-Based Fiber-Optic Biosensors Using a Fabry-Perot Resonator Structure

    Directory of Open Access Journals (Sweden)

    Meng-Chang Hsieh

    2015-02-01

    Full Text Available Fluorescent biosensors have been widely used in biomedical applications. To amplify the intensity of fluorescence signals, this study developed a novel structure for an evanescent wave fiber-optic biosensor by using a Fabry-Perot resonator structure. An excitation light was coupled into the optical fiber through a laser-drilled hole on the proximal end of the resonator. After entering the resonator, the excitation light was reflected back and forth inside the resonator, thereby amplifying the intensity of the light in the fiber. Subsequently, the light was used to excite the fluorescent molecules in the reactive region of the sensor. The experimental results showed that the biosensor signal was amplified eight-fold when the resonator reflector was formed using a 92% reflective coating. Furthermore, in a simulation, the biosensor signal could be amplified 20-fold by using a 99% reflector.

  15. Spectrally and Energy Efficient OFDM (SEE-OFDM) for Intensity Modulated Optical Wireless Systems

    OpenAIRE

    Lam, Emily; Wilson, Sarah Kate; Elgala, Hany; Little, Thomas D. C.

    2015-01-01

    Spectrally and energy efficient orthogonal frequency division multiplexing (SEE-OFDM) is an optical OFDM technique based on combining multiple asymmetrically clipped optical OFDM (ACO-OFDM) signals into one OFDM signal. By summing different components together, SEE-OFDM can achieve the same spectral efficiency as DC-biased optical OFDM (DCO-OFDM) without an energy-inefficient DC-bias. This paper introduces multiple methods for decoding a SEE-OFDM symbol and shows that an iterative decoder wit...

  16. The relationship among pressure ulcer risk factors, incidence and nursing documentation in hospital-acquired pressure ulcer patients in intensive care units.

    Science.gov (United States)

    Li, Dan

    2016-08-01

    To explore the quality/comprehensiveness of nursing documentation of pressure ulcers and to investigate the relationship between the nursing documentation and the incidence of pressure ulcers in four intensive care units. Pressure ulcer prevention requires consistent assessments and documentation to decrease pressure ulcer incidence. Currently, most research is focused on devices to prevent pressure ulcers. Studies have rarely considered the relationship among pressure ulcer risk factors, incidence and nursing documentation. Thus, a study to investigate this relationship is needed to fill this information gap. A retrospective, comparative, descriptive, correlational study. A convenience sample of 196 intensive care units patients at the selected medical centre comprised the study sample. All medical records of patients admitted to intensive care units between the time periods of September 1, 2011 through September 30, 2012 were audited. Data used in the analysis included 98 pressure ulcer patients and 98 non-pressure ulcer patients. The quality and comprehensiveness of pressure ulcer documentation were measured by the modified European Pressure Ulcer Advisory Panel Pressure Ulcers Assessment Instrument and the Comprehensiveness in Nursing Documentation instrument. The correlations between quality/comprehensiveness of pressure ulcer documentation and incidence of pressure ulcers were not statistically significant. Patients with pressure ulcers had longer length of stay than patients without pressure ulcers stay. There were no statistically significant differences in quality/comprehensiveness scores of pressure ulcer documentation between dayshift and nightshift. This study revealed a lack of quality/comprehensiveness in nursing documentation of pressure ulcers. This study demonstrates that staff nurses often perform poorly on documenting pressure ulcer appearance, staging and treatment. Moreover, nursing documentation of pressure ulcers does not provide a complete

  17. INCIDENCE, OUTCOME AND RISK FACTORS FOR SEPSIS--A TWO YEAR RETROSPECTIVE STUDY AT SURGICAL INTENSIVE CARE UNIT OF A TEACHING HOSPITAL IN PAKISTAN.

    Science.gov (United States)

    Asghar, All; Hashmi, Madiha; Rashid, Saima; Khan, Fazal Hameed

    2016-01-01

    Sepsis is amongst the leading causes of admission to the intensive care units and is associated with a high mortality. However, data from developing countries is scares. Aim of conducting this study was to determine the incidence, outcome and risk factors for sepsis on admission to surgical intensive care unit (SICU) of a teaching hospital in Pakistan. Two year retrospective observational study included all consecutive adult admissions to the surgical intensive care unit (SICU) of a University Hospital, from January 2012 to December 2013. Two hundred and twenty-nine patients met the inclusion criteria. Average age of the patients was 46.35 ± 18.23 years (16-85), mean Acute Physiology and Chronic Health Evaluation II (APACHE II) score was 15.92 ± 8.13 and males were 67.6%. Median length of ICU stay was 4 [IQR 5]. 43% patients fulfilled the criteria of sepsis at the time of admission to the SICU and incidence of severe sepsis/septic shock was 35%. Abdominal sepsis was the most frequent source of infection (57.5%). The overall intensive care unit mortality was 32.31% but the mortality of sepsis-group was 51.15% as compared to 17.7% of the non- sepsis group. Stepwise logistic regression model showed that increasing age, female gender, non-operative admission, admission under general surgery and co-morbidities like ischaemic heart disease and chronic kidney disease were significant predictors of sepsis. The incidence of sepsis and severe sepsis/septic shock, on admission to SICU is high and mortality of the sepsis group is nearly three times the mortality of the non-sepsis group.

  18. Incidence, outcome and risk factors for sepsis - a two year retrospective study at surgical intensive care unit of a teaching hospital in Pakistan

    International Nuclear Information System (INIS)

    Asghar, A.; Hashmi, M.; Rashid, S.; Khan, F.H.

    2016-01-01

    Background: Sepsis is amongst the leading causes of admission to the intensive care units and is associated with a high mortality. However, data from developing countries is scarse. Aim of conducting this study was to determine the incidence, outcome and risk factors for sepsis on admission to surgical intensive care unit (SICU) of a teaching hospital in Pakistan. Methods: Two year retrospective observational study included all consecutive adult admissions to the surgical intensive care unit (SICU) of a University Hospital, from January 2012 to December 2013. Results: Two hundred and twenty-nine patients met the inclusion criteria. Average age of the patients was 46.35±18.23 years (16-85), mean Acute Physiology and Chronic Health Evaluation II (APACHE II) score was 15.92±8.13 and males were 67.6 percentage. Median length of ICU stay was 4 [IQR 5]. 43 percentage patients fulfilled the criteria of sepsis at the time of admission to the SICU and incidence of severe sepsis/septic shock was 35 percentage. Abdominal sepsis was the most frequent source of infection (57.5 percentage). The overall intensive care unit mortality was 32.31 percentage but the mortality of sepsis-group was 51.15 percentage as compared to 17.7 percentage of the non-sepsis group. Stepwise logistic regression model showed that increasing age, female gender, non-operative admission, admission under general surgery and co-morbidities like ischaemic heart disease and chronic kidney disease were significant predictors of sepsis. Conclusion: The incidence of sepsis and severe sepsis/septic shock, on admission to SICU is high and mortality of the sepsis group is nearly three times the mortality of the non-sepsis group. (author)

  19. Incidence and predictors of readmission to the cardiac surgery intensive care unit: A retrospective cohort study in Greece

    Directory of Open Access Journals (Sweden)

    Konstantinos Giakoumidakis

    2014-01-01

    Conclusions: One intraoperative and three preoperative variables are associated strongly with higher probability for ICU readmission. Shorter CPB duration could contribute to lower ICU readmission incidence. In addition, the early identification of high risk patients for readmission in the cardiac surgery ICU could encourage both the more efficient healthcare planning and resources allocation.

  20. Which aspects of safety culture predict incident reporting behavior in neonatal intensive care units? A multilevel analysis

    NARCIS (Netherlands)

    Snijders, Cathelijne; Kollen, Boudewijn J.; van Lingen, Richard A.; Fetter, Willem P. F.; Molendijk, Harry; Kok, J. H.; te Pas, E.; Pas, H.; van der Starre, C.; Bloemendaal, E.; Lopes Cardozo, R. H.; Molenaar, A. M.; Giezen, A.; van Lingen, R. A.; Maat, H. E.; Molendijk, A.; Snijders, C.; Lavrijssen, S.; Mulder, A. L. M.; de Kleine, M. J. K.; Koolen, A. M. P.; Schellekens, M.; Verlaan, W.; Vrancken, S.; Fetter, W. P. F.; Schotman, L.; van der Zwaan, A.; van der Tuijn, Y.; Tibboel, D.; van der Schaaf, T. W.; Klip, H.; Kollen, B. J.

    2009-01-01

    OBJECTIVES: Safety culture assessments are increasingly used to evaluate patient-safety programs. However, it is not clear which aspects of safety culture are most relevant in understanding incident reporting behavior, and ultimately improving patient safety. The objective of this study was to

  1. Incidence and prognostic factor of ethambutol-related optic neuropathy: 10-year experience in southern Taiwan

    Directory of Open Access Journals (Sweden)

    Shih-Chou Chen

    2015-07-01

    Full Text Available To investigate the incidence and prognostic factors of ethambutol-related optic neuropathy (EON in one medical center of southern Taiwan, a retrospective chart review study with 4803 newly diagnosed tuberculosis cases from January 2002 to July 2011 at one medical center hospital in southern Taiwan were reviewed. Of these patients, 1004 had ophthalmic records. Sixty-two cases (1.29% experienced visual impairment and were diagnosed as EON with mean visual acuity of 0.86 ± 0.69 by logMAR. Sixteen of the 62 patients had a follow-up time > 6 months. Of these, eight patients (50% showed visual improvement (an increase in visual acuity of ≥ 2 Snellen lines after ethambutol was discontinued. Another eight patients (50% showed no visual improvement. We analyzed multiple factors between the patients with and without visual improvement by logistic regression, including body weight, daily dose of ethambutol, duration of ethambutol use, cumulative dose of ethambutol, renal function, underlying disease of diabetes mellitus, hypertension, and initial visual acuity showed no statistically significant difference. In conclusion, the incidence of EON was 1.29%. Half of the patients showed visual improvement after discontinuation of ethambutol, and no obvious prognostic factors were found to facilitate the vision recovery. Ethambutol should be discontinued as soon as EON is suspected.

  2. Linear optical absorption spectra of mesoscopic structures in intense THz fields: Free-particle properties

    DEFF Research Database (Denmark)

    Johnsen, Kristinn; Jauho, Antti-Pekka

    1998-01-01

    We theoretically study the effect of THz radiation on the linear optical absorption spectra of semiconductor structures. A general theoretical framework, based on nonequilibrium Green functions, is formulated and applied to the calculation of linear optical absorption spectrum for several...... stable steps appear in the absorption spectrum when conditions for dynamical localization are met. [S0163-1829(95)03412-2]....

  3. Influence of Polarization of the Incident Beam on Integrated Intensities in X-Ray Energy-Dispersive Diffractometry

    DEFF Research Database (Denmark)

    Olsen, J. Staun; Buras, B.; Jensen, T.

    1978-01-01

    Polarization measurements of the primary X-ray beam produced by thick copper and tungsten anodes are reported and formulas derived for integrated intensities of Bragg reflections in energy-dispersive diffractometry with the polarization of the primary beam taken into account. It was found...

  4. Risk of Incident Diabetes With Intensive-Dose Compared With Moderate-Dose Statin Therapy A Meta-analysis

    NARCIS (Netherlands)

    Preiss, David; Seshasai, Sreenivasa Rao Kondapally; Welsh, Paul; Murphy, Sabina A.; Ho, Jennifer E.; Waters, David D.; Demicco, David A.; Barter, Philip; Cannon, Christopher P.; Sabatine, Marc S.; Braunwald, Eugene; Kastelein, John J. P.; de Lemos, James A.; Blazing, Michael A.; Pedersen, Terje R.; Tikkanen, Matti J.; Sattar, Naveed; Ray, Kausik K.

    2011-01-01

    Context A recent meta-analysis demonstrated that statin therapy is associated with excess risk of developing diabetes mellitus. Objective To investigate whether intensive-dose statin therapy is associated with increased risk of new-onset diabetes compared with moderate-dose statin therapy. Data

  5. Analysis of intensive aerosol optical properties measured at the Jungfraujoch station

    Energy Technology Data Exchange (ETDEWEB)

    Li, F.; Nyeki, S.; Baltensperger, U.; Weingartner, E.; Lugauer, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Characterisation of atmospheric aerosol optical properties at the Jungfraujoch has been conducted to deliver basic data for comparison with those from NOAA baseline atmospheric monitoring stations. (author) 2 figs., 2 refs.

  6. An image-processing method to detect sub-optical features based on understanding noise in intensity measurements.

    Science.gov (United States)

    Bhatia, Tripta

    2018-02-01

    Accurate quantitative analysis of image data requires that we distinguish between fluorescence intensity (true signal) and the noise inherent to its measurements to the extent possible. We image multilamellar membrane tubes and beads that grow from defects in the fluid lamellar phase of the lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine dissolved in water and water-glycerol mixtures by using fluorescence confocal polarizing microscope. We quantify image noise and determine the noise statistics. Understanding the nature of image noise also helps in optimizing image processing to detect sub-optical features, which would otherwise remain hidden. We use an image-processing technique "optimum smoothening" to improve the signal-to-noise ratio of features of interest without smearing their structural details. A high SNR renders desired positional accuracy with which it is possible to resolve features of interest with width below optical resolution. Using optimum smoothening, the smallest and the largest core diameter detected is of width [Formula: see text] and [Formula: see text] nm, respectively, discussed in this paper. The image-processing and analysis techniques and the noise modeling discussed in this paper can be used for detailed morphological analysis of features down to sub-optical length scales that are obtained by any kind of fluorescence intensity imaging in the raster mode.

  7. Cocaine-related admissions to an intensive care unit: a five-year study of incidence and outcomes.

    LENUS (Irish Health Repository)

    Galvin, S

    2010-02-01

    Cocaine misuse is increasing and it is evidently considered a relatively safe drug of abuse in Ireland. To address this perception, we reviewed the database of an 18-bed Dublin intensive care unit, covering all admissions from 2003 to 2007. We identified cocaine-related cases, measuring hospital mortality and long-term survival in early 2009. Cocaine-related admissions increased from around one annually in 2003-05 to 10 in 2007. Their median (IQR [range]) age was 25 (21-35 [17-47]) years and 78% were male. The median (IQR [range]) APACHE II score was 16 (11-27 [5-36]) and length of intensive care stay was 5 (3-9 [1-16]) days. Ten patients died during their hospital stay. A further five had died by the time of follow-up, a median of 24 months later. One was untraceable. Cocaine toxicity necessitating intensive care is increasingly common in Dublin. Hospital mortality in this series was 52%. These findings may help to inform public attitudes to cocaine.

  8. Percutaneous dilatational tracheostomy without fiber optic bronchoscopy-Evaluation of 80 intensive care units cases

    NARCIS (Netherlands)

    J.A. Calvache (Jose Andrés); R.A. Molina García (Rodrigo); A.L. Trochez (Adolfo); J. Benitez (Javier); L.A. Flga (Lucía Arroyo)

    2013-01-01

    textabstractBackground: The development of percutaneous dilatational tracheostomy techniques (PDT) has facilitated the procedure in Intensive Care Units (ICU). Objective: To describe the early intra and post-operative complications in ICU patients requiring percutaneous dilatational tracheostomy

  9. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    Energy Technology Data Exchange (ETDEWEB)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-06-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band ({lt}5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is {minus}110 dB/Hz, with uncertainty {le}0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by {le}0.2 dB. {copyright} 2001 Optical Society of America

  10. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    International Nuclear Information System (INIS)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-01-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band (<5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is -110 dB/Hz, with uncertainty ≤0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by ≤0.2 dB. [copyright] 2001 Optical Society of America

  11. Non-interferometric determination of optical anisotropy in highly-oriented fibres using transport intensity equation technique

    Science.gov (United States)

    Sokkar, T. Z. N.; El-Farahaty, K. A.; El-Bakary, M. A.; Raslan, M. I.; Omar, E. Z.; Hamza, A. A.

    2018-03-01

    The optical setup of the transport intensity equation (TIE) technique is developed to be valid for measuring the optical properties of the highly-oriented anisotropic fibres. This development is based on the microstructure models of the highly-oriented anisotropic fibres and the principle of anisotropy. We provide the setup of TIE technique with polarizer which is controlled via stepper motor. This developed technique is used to investigate the refractive indices in the parallel and perpendicular polarization directions of light for the highly-oriented poly (ethylene terephthalate) (PET) fibres and hence its birefringence. The obtained results through the developed TIE technique for PET fibre are compared with that determined experimentally using the Mach-Zehnder interferometer under the same conditions. The comparison shows a good agreement between the obtained results from the developed technique and that obtained from the Mach-Zehnder interferometer technique.

  12. Incidence of carbapenem resistant nonfermenting gram negative bacilli from patients with respiratory infections in the intensive care units

    Directory of Open Access Journals (Sweden)

    Gladstone P

    2005-01-01

    Full Text Available Resistance to carbapenems is commonly seen in nonfermenting gram negative bacilli (NFGNB. We document herein the prevalence of carbapenem resistance in NFGNB isolated from patients with respiratory tract infections in the intensive care units (ICUs. A total of 460 NFGNB were isolated from 606 endotracheal aspirate specimens during January through December 2003, of which 56 (12.2% were found to be resistant to imipenem and meropenem. Of these, 24 (42.8% were Pseudomonas aeruginosa , 8 (14.2% were Acinetobacter spp. and 24 (42.8% were other NFGNB. Stringent protocols such as antibiotic policies and resistance surveillance programs are mandatory to curb these bacteria in ICU settings.

  13. A Self-Referenced Optical Intensity Sensor Network Using POFBGs for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Alberto Tapetado Moraleda

    2014-12-01

    Full Text Available This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG and polymer FBGs (POFBG is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown.

  14. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposure

    Czech Academy of Sciences Publication Activity Database

    Khorsand, A.R.; Sobierajski, R.; Louis, E.; Bruijn, S.; van Hattum, E.D.; van de Kruijs, R.W.E.; Jurek, M.; Klinger, D.; Pelka, J. B.; Juha, Libor; Burian, Tomáš; Chalupský, Jaromír; Cihelka, Jaroslav; Hájková, Věra; Vyšín, Luděk; Jastrow, U.; Stojanovic, N.; Toleikis, S.; Wabnitz, H.; Tiedtke, K.; Sokolowski-Tinten, K.; Shymanovich, U.; Krzywinski, J.; Hau-Riege, S.; London, R.; Gleeson, A.; Gullikson, E.M.; Bijkerk, F.

    2010-01-01

    Roč. 18, č. 2 (2010), 700-712 ISSN 1094-4087 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : laser damage * thermal effects * multilayers * optical design and fabrication * free-electron lasers Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.749, year: 2010

  15. A self-referenced optical intensity sensor network using POFBGs for biomedical applications.

    Science.gov (United States)

    Tapetado Moraleda, Alberto; Sánchez Montero, David; Webb, David J; Vázquez García, Carmen

    2014-12-12

    This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF)-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG) and polymer FBGs (POFBG) is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown.

  16. Descriptive study of current therapeutic practices, clinical reproductive findings and incidence of pregnancy loss in intensively managed thoroughbred mares.

    Science.gov (United States)

    Rose, B V; Firth, M; Morris, B; Roach, J M; Wathes, D C; Verheyen, K L P; de Mestre, A M

    2018-01-01

    Therapeutic practices in equine reproductive medicine have dramatically evolved over the last 20 years but current usage is not described. The aims of this study were to provide a description of medication use and clinical findings of reproductive examinations alongside measures of reproductive efficiency in thoroughbreds. A prospective cohort study was conducted in the 2013 and 2014 breeding seasons. Mare and stallion details, information on veterinary interventions and findings of reproductive ultrasound scans were collected using questionnaires and entered into a custom-designed Microsoft Access database. Descriptive summary statistics were derived directly from the database and using Microsoft Excel. Information was collected from 2246 pregnancies in 1754 mares from 29 stud farms. Ovulatory induction agents were used in 91.8% of cases, oestrus induction agents in 38.4% and covering therapies in 62.7%. Intrauterine antimicrobials were used in 49.6% of mares. Single pregnancies accounted for 83.9% of pregnancies, twins for 15.3% and triplets for 0.7%. The overall incidence of pregnancy loss between days 15-42 was 6.4% (95% CI 5.4%, 7.4%) and 1.6% (95% CI 1.1%, 2.1%) between days 43-65. A further 1.3% of pregnancies were lost by October and 4.5% by birth (including stillbirths). Eighty-three percent of all pregnancies resulted in a live foal. In conclusion, there has been a considerable increase in the use of reproductive therapeutics over the last 12 years. Nonetheless, incidence of pregnancy loss and live foal percentages remain essentially unchanged. Risk factor studies are required to determine if the substantial increase in therapeutic usage is conferring positive benefits. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Incidence of and risk factors for infection or colonization of vancomycin-resistant enterococci in patients in the intensive care unit.

    Directory of Open Access Journals (Sweden)

    Sung-Ching Pan

    Full Text Available The prevalence of vancomycin-resistant enterococci (VRE colonization or infection in the hospital setting has increased globally. Many previous studies had analysed the risk factors for acquiring VRE, based on cross-sectional studies or prevalent cases. However, the actual incidence of and risk factors for VRE remain unclear. The present study was conducted in order to clarify the incidence of and risk factors for VRE in the intensive care unit (ICU. From 1(st April 2008 to 31(st March 2009, all patients admitted to a surgical ICU (SICU were put on active surveillance for VRE. The surveillance cultures, obtained by rectal swab, were taken on admission, weekly while staying in the SICU, and on discharge from the SICU. A total of 871 patients were screened. Among them, 34 were found to carry VRE before their admission to the SICU, and 47 acquired VRE during their stay in the SICU, five of whom developed VRE infections. The incidence of newly acquired VRE during ICU stay was 21.9 per 1000 patient-days (95% confidence interval [CI], 16.4-29.1. Using multivariate analysis by logistic regression, we found that the length of ICU stay was an independent risk factor for new acquisition of VRE. In contrast, patients with prior exposure to first-generation cephalosporin were significantly less likely to acquire VRE. Strategies to reduce the duration of ICU stay and prudent usage of broad-spectrum antibiotics are the keys to controlling VRE transmission.

  18. Trends in the incidence rate of device-associated infections in intensive care units after the establishment of the Korean Nosocomial Infections Surveillance System.

    Science.gov (United States)

    Choi, J Y; Kwak, Y G; Yoo, H; Lee, S-O; Kim, H B; Han, S H; Choi, H J; Kim, Y K; Kim, S R; Kim, T H; Lee, H; Chun, H K; Kim, J-S; Eun, B W; Kim, D W; Koo, H-S; Bae, G-R; Lee, K

    2015-09-01

    The effectiveness of continuous nationwide surveillance on healthcare-associated infections should be investigated in each country. To assess the rate of device-associated infections (DAIs) in intensive care units (ICUs) since the establishment of the Korean Nosocomial Infections Surveillance System (KONIS). Nationwide data were obtained on the incidence rate of DAI in ICUs reported to KONIS by all participating hospitals. The three major DAIs were studied: ventilator-associated pneumonia (VAP), central line-associated bloodstream infection (CABSI), and catheter-associated urinary tract infection (CAUTI). The pooled and year-wise incidence rates (cases per 1000 device-days) of these DAIs were determined for the period 2006 and 2012. In addition, data from institutions that had participated in KONIS for at least three consecutive years were analysed separately. The number of ICUs participating in KONIS gradually increased from 76 in 2006 to 162 in 2012. Between 2006 and 2012, the incidence rate per 1000 device-days for VAP decreased significantly from 3.48 to 1.64 (F = 11, P Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Probing intensity limits of LHC-Type bunches in CERN SPS with nominal optics

    CERN Document Server

    Adrian, G; Andujar, O; Argyropoulos, T; Axensalva, J; Baldy, J; Bartosik, H; Cettour Cave, S; Chapuis, F; Comblin, JF; Cornelis, K; Cotte, D; Cunnington, K; Damerau, H; Delrieux, M; Duran-Lopez, JL; Esteban Mueller, J; Findlay, A; Fleuret, J; Follin, F; Freyermuth, P; Genoud, H; Gilardoni, S; Guerrero, A; Hancock, S; Hanke, K; Hans, O; Hazelaar, R; Höfle, W; Jensen, L; Kuczerowski, J; Le Borgne, Y; Maillet, R; Manglunki, D; Massot, S; Matli, E; Métral, G; Métral, E; Mikulec, B; Nonglaton, JM; Ovalle, E; Papaphilippou, Y; Pereira, L; Peters, F; Rey, A; Ridewood, J; Rumolo, G; Salvant, B; Sanchez Alvarez, JL; Shaposhnikova, E; Steerenberg, R; Steinhagen, R; Tan, J; Vandorpe, B; Veyrunes, E

    2011-01-01

    Some of the upgrade scenarios of the high-luminosity LHC require large intensity per bunch from the injector chain. Single bunch beams with intensities of up to 3.5 to 4e11 p/b and nominal emittances were successfully produced in the PS Complex and delivered to the SPS in 2010. This contribution presents results of studies with this new intense beam in the SPS to probe single bunch intensity limitations with nominal gamma transition. In particular, the vertical Transverse Mode Coupling Instability (TMCI) threshold with low chromaticity was observed at 1.6e11 p/b for single nominal LHC bunches in the SPS. With increased vertical chromaticity, larger intensities could be injected, stored along the flat bottom and accelerated up to 450 GeV/c. However, significant losses and/or transverse emittance blow up were then observed. Longitudinal and transverse optimization efforts in the PSB, PS and SPS were put in place to minimize this beam degradation and succeeded to obtain single 2.5e11 p/b LHC type bunches with sa...

  20. Low Group Delay Dispersion Optical Coating for Broad Bandwidth High Reflection at 45° Incidence, P Polarization of Femtosecond Pulses with 900 nm Center Wavelength

    Directory of Open Access Journals (Sweden)

    John C. Bellum

    2016-03-01

    Full Text Available We describe an optical coating design suitable for broad bandwidth high reflection (BBHR at 45° angle of incidence (AOI, P polarization (Ppol of femtosecond (fs laser pulses whose wavelengths range from 800 to 1000 nm. Our design process is guided by quarter-wave HR coating properties. The design must afford low group delay dispersion (GDD for reflected light over the broad, 200 nm bandwidth in order to minimize temporal broadening of the fs pulses due to dispersive alteration of relative phases between their frequency components. The design should also be favorable to high laser-induced damage threshold (LIDT. We base the coating on TiO2/SiO2 layer pairs produced by means of e-beam evaporation with ion-assisted deposition, and use OptiLayer Thin Film Software to explore designs starting with TiO2/SiO2 layers having thicknesses in a reverse chirped arrangement. This approach led to a design with R > 99% from 800 to 1000 nm and GDD < 20 fs2 from 843 to 949 nm (45° AOI, Ppol. The design’s GDD behaves in a smooth way, suitable for GDD compensation techniques, and its electric field intensities show promise for high LIDTs. Reflectivity and GDD measurements for the initial test coating indicate good performance of the BBHR design. Subsequent coating runs with improved process calibration produced two coatings whose HR bands satisfactorily meet the design goals. For the sake of completeness, we summarize our previously reported transmission spectra and LIDT test results with 800 ps, 8 ps and 675 fs pulses for these two coatings, and present a table of the LIDT results we have for all of our TiO2/SiO2 BBHR coatings, showing the trends with test laser pulse duration from the ns to sub-ps regimes.

  1. Surface optical vortices

    Science.gov (United States)

    Lembessis, V. E.; Babiker, M.; Andrews, D. L.

    2009-01-01

    It is shown how the total internal reflection of orbital-angular-momentum-endowed light can lead to the generation of evanescent light possessing rotational properties in which the intensity distribution is firmly localized in the vicinity of the surface. The characteristics of these surface optical vortices depend on the form of the incident light and on the dielectric mismatch of the two media. The interference of surface optical vortices is shown to give rise to interesting phenomena, including pattern rotation akin to a surface optical Ferris wheel. Applications are envisaged to be in atom lithography, optical surface tweezers, and spanners.

  2. Correlations in photon-numbers and integrated intensities in parametric processes involving three optical fields

    Czech Academy of Sciences Publication Activity Database

    Peřina, Jan; Křepelka, Jaromír; Peřina ml., Jan; Bondani, M.; Allevi, A.; Andreoni, A.

    2009-01-01

    Roč. 53, č. 3 (2009), 373-382 ISSN 1434-6060 R&D Projects: GA AV ČR KAN301370701; GA MŠk(CZ) 1M06002 Institutional research plan: CEZ:AV0Z10100522 Keywords : parametric process * three-mode state * sub-Poisson statistics * conditional measurement Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.420, year: 2009

  3. A review of biomass burning emissions part III: intensive optical properties of biomass burning particles

    Directory of Open Access Journals (Sweden)

    J. S. Reid

    2005-01-01

    Full Text Available Because of its wide coverage over much of the globe, biomass burning has been widely studied in the context of direct radiative forcing. Such study is warranted as smoke particles scatter and at times absorb solar radiation efficiently. Further, as much of what is known about smoke transport and impacts is based on remote sensing measurements, the optical properties of smoke particles have far reaching effects into numerous aspects of biomass burning studies. Global estimates of direct forcing have been widely varying, ranging from near zero to −1 W m-2. A significant part of this difference can be traced to varying assumptions on the optical properties of smoke. This manuscript is the third part of four examining biomass-burning emissions. Here we review and discuss the literature concerning measurement and modeling of optical properties of biomass-burning particles. These include available data from published sensitivity studies, field campaigns, and inversions from the Aerosol Robotic Network (AERONET of Sun photometer sites. As a whole, optical properties reported in the literature are varied, reflecting both the dynamic nature of fires, variations in smoke aging processes and differences in measurement technique. We find that forward modeling or ''internal closure'' studies ultimately are of little help in resolving outstanding measurement issues due to the high degree of degeneracy in solutions when using ''reasonable'' input parameters. This is particularly notable with respect to index of refraction and the treatment of black carbon. Consequently, previous claims of column closure may in fact be more ambiguous. Differences between in situ and retrieved ωo values have implications for estimates of mass scattering and mass absorption efficiencies. In this manuscript we review and discuss this community dataset. Strengths and lapses are pointed out, future research topics are prioritized, and best estimates and uncertainties of key

  4. Surface optical vortices

    OpenAIRE

    Lembessis, V. E.; Babiker, M.; Andrews, D L.

    2009-01-01

    It is shown how the total internal reflection of orbital-angular-momentum-endowed light can lead to the generation of evanescent light possessing rotational properties in which the intensity distribution is firmly localized in the vicinity of the surface. The characteristics of these surface optical vortices depend on the form of the incident light and on the dielectric mismatch of the two media. The interference of surface optical vortices is shown to give rise to interesting phenomena, incl...

  5. Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States); Dickerson, Bryan [Luna Innovations, Inc. (United States)

    2013-01-03

    The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica's optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and

  6. Testing of Performance of Optical Fibers Under Irradiation in Intense Radiation Fields, When Subjected to High Temperature

    International Nuclear Information System (INIS)

    Blue, Thomas; Windl, Wolfgang; Dickerson, Bryan

    2013-01-01

    The primary objective of this project is to measure and model the performance of optical fibers in intense radiation fields when subjected to very high temperatures. This research will pave the way for fiber optic and optically based sensors under conditions expected in future high-temperature gas-cooled reactors. Sensor life and signal-to-noise ratios are susceptible to attenuation of the light signal due to scattering and absorbance in the fibers. This project will provide an experimental and theoretical study of the darkening of optical fibers in high-radiation and high-temperature environments. Although optical fibers have been studied for moderate radiation fluence and flux levels, the results of irradiation at very high temperatures have not been published for extended in-core exposures. Several previous multi-scale modeling efforts have studied irradiation effects on the mechanical properties of materials. However, model-based prediction of irradiation-induced changes in silica'@@s optical transport properties has only recently started to receive attention due to possible applications as optical transmission components in fusion reactors. Nearly all damage-modeling studies have been performed in the molecular-dynamics domain, limited to very short times and small systems. Extended-time modeling, however, is crucial to predicting the long-term effects of irradiation at high temperatures, since the experimental testing may not encompass the displacement rate that the fibers will encounter if they are deployed in the VHTR. The project team will pursue such extended-time modeling, including the effects of the ambient and recrystallization. The process will be based on kinetic MC modeling using the concept of amorphous material consisting of building blocks of defect-pairs or clusters, which has been successfully applied to kinetic modeling in amorphized and recrystallized silicon. Using this procedure, the team will model compensation for rate effects, and

  7. Genetic fitness and selection intensity in a population affected with high-incidence spinocerebellar ataxia type 1.

    Science.gov (United States)

    Platonov, Fedor A; Tyryshkin, Kathrin; Tikhonov, Dmitriy G; Neustroyeva, Tatyana S; Sivtseva, Tatyana M; Yakovleva, Natalya V; Nikolaev, Valerian P; Sidorova, Oksana G; Kononova, Sardana K; Goldfarb, Lev G; Renwick, Neil M

    2016-07-01

    Spinocerebellar ataxia type 1 (SCA1) is the major and likely the only type of autosomal dominant cerebellar ataxia in the Sakha (Yakut) people of Eastern Siberia. The prevalence rate of SCA1 has doubled over the past 21 years peaking at 46 cases per 100,000 rural population. The age at death correlates closely with the number of CAG triplet repeats in the mutant ATXN1 gene (r = -0.81); most patients with low-medium (39-55) repeat numbers survived until the end of reproductive age. The number of CAG repeats expands in meiosis, particularly in paternal transmissions; the average total increase in intergenerational transmissions in our cohort was estimated at 1.6 CAG repeats. The fertility rates of heterozygous carriers of 39-55 CAG repeats in women were no different from those of the general Sakha population. Overall, the survival of mutation carriers through reproductive age, unaltered fertility rates, low childhood mortality in SCA1-affected families, and intergenerational transmission of increasing numbers of CAG repeats in the ATXN1 gene indicate that SCA1 in the Sakha population will be maintained at high prevalence levels. The low (0.19) Crow's index of total selection intensity in our SCA1 cohort implies that this mutation is unlikely to be eliminated through natural selection alone.

  8. Incidence and Risk Factors for Delirium among Mechanically Ventilated Patients in an African Intensive Care Setting: An Observational Multicenter Study

    Directory of Open Access Journals (Sweden)

    Arthur Kwizera

    2015-01-01

    Full Text Available Aim. Delirium is common among mechanically ventilated patients in the intensive care unit (ICU. There are little data regarding delirium among mechanically ventilated patients in Africa. We sought to determine the burden of delirium and associated factors in Uganda. Methods. We conducted a multicenter prospective study among mechanically ventilated patients in Uganda. Eligible patients were screened daily for delirium using the confusional assessment method (CAM-ICU. Comparisons were made using t-test, chi-squares, and Fisher’s exact test. Predictors were assessed using logistic regression. The level of statistical significance was set at P<0.05. Results. Of 160 patients, 81 (51% had delirium. Median time to onset of delirium was 3.7 days. At bivariate analysis, history of mental illness, sedation, multiorgan dysfunction, neurosurgery, tachypnea, low mean arterial pressure, oliguria, fevers, metabolic acidosis, respiratory acidosis, anaemia, physical restraints, marital status, and endotracheal tube use were significant predictors. At multivariable analysis, having a history of mental illness, sedation, respiratory acidosis, higher PEEP, endotracheal tubes, and anaemia predicted delirium. Conclusion. The prevalence of delirium in a young African population is lower than expected considering the high mortality. A history of mental illness, anaemia, sedation, endotracheal tube use, and respiratory acidosis were factors associated with delirium.

  9. Intensity-modulated polarizabilities and magic trapping of alkali-metal and divalent atoms in infrared optical lattices

    Science.gov (United States)

    Topcu, Turker; Derevianko, Andrei

    2014-05-01

    Long range interactions between neutral Rydberg atoms has emerged as a potential means for implementing quantum logical gates. These experiments utilize hyperfine manifold of ground state atoms to act as a qubit basis, while exploiting the Rydberg blockade mechanism to mediate conditional quantum logic. The necessity for overcoming several sources of decoherence makes magic wavelength trapping in optical lattices an indispensable tool for gate experiments. The common wisdom is that atoms in Rydberg states see trapping potentials that are essentially that of a free electron, and can only be trapped at laser intensity minima. We show that although the polarizability of a Rydberg state is always negative, the optical potential can be both attractive or repulsive at long wavelengths (up to ~104 nm). This opens up the possibility of magic trapping Rydberg states with ground state atoms in optical lattices, thereby eliminating the necessity to turn off trapping fields during gate operations. Because the wavelengths are near the CO2 laser band, the photon scattering and the ensuing motional heating is also reduced compared to conventional traps near low lying resonances, alleviating an important source of decoherence. This work was supported by the National Science Foundation (NSF) Grant No. PHY-1212482.

  10. Progress in Y-00 physical cipher for Giga bit/sec optical data communications (intensity modulation method)

    Science.gov (United States)

    Hirota, Osamu; Futami, Fumio

    2014-10-01

    To guarantee a security of Cloud Computing System is urgent problem. Although there are several threats in a security problem, the most serious problem is cyber attack against an optical fiber transmission among data centers. In such a network, an encryption scheme on Layer 1(physical layer) with an ultimately strong security, a small delay, and a very high speed should be employed, because a basic optical link is operated at 10 Gbit/sec/wavelength. We have developed a quantum noise randomied stream cipher so called Yuen- 2000 encryption scheme (Y-00) during a decade. This type of cipher is a completely new type random cipher in which ciphertext for a legitimate receiver and eavesdropper are different. This is a condition to break the Shannon limit in theory of cryptography. In addition, this scheme has a good balance on a security, a speed and a cost performance. To realize such an encryption, several modulation methods are candidates such as phase-modulation, intensity-modulation, quadrature amplitude modulation, and so on. Northwestern university group demonstrated a phase modulation system (α=η) in 2003. In 2005, we reported a demonstration of 1 Gbit/sec system based on intensity modulation scheme(ISK-Y00), and gave a design method for quadratic amplitude modulation (QAM-Y00) in 2005 and 2010. An intensity modulation scheme promises a real application to a secure fiber communication of current data centers. This paper presents a progress in quantum noise randomized stream cipher based on ISK-Y00, integrating our theoretical and experimental achievements in the past and recent 100 Gbit/sec(10Gbit/sec × 10 wavelengths) experiment.

  11. On the statistical relationship between cloud optical and microphysical characteristics and rainfall intensity for convective storms over the Mediterranean

    Directory of Open Access Journals (Sweden)

    E. Cattani

    2009-12-01

    Full Text Available The relationship between the multi-spectral cloud field characterization from the Advanced Very High Resolution Radiometer (AVHRR and the rainfall intensities from the Advanced Microwave Sounding Unit-module B (AMSU-B data were studied for a convective storm event, which occurred during the first 15 days of June 2007 over the Mediterranean. The cloud products exploited in this analysis, cloud mask, type, optical thickness, and effective radius, are obtained from the NOAA-NESDIS operational processing system Clouds from the AVHRR-Extended algorithm (CLAVR-x, whereas the rain intensity values are retrieved from the AMSU-B brightness temperatures via a fast algorithm, using opaque frequencies (centred at 183 GHz to correct for the presence of water vapour affecting the retrieval results. The algorithm is conceived to discriminate between convective and stratiform rain using a suitable set of thresholds; the retrieval is subsequently carried out separately for the two types.

    A test for the discrimination of precipitating from non-precipitating areas was based on the comparison between the precipitation information and the retrieved cloud parameters. The test produced a cloud optical thickness threshold value, beyond which the precipitation initiates, and an effective radius range for the identification of the precipitating clouds. The results stemming from the application of the test to the June 2007 case study are very encouraging, although still preliminary and restricted to the analyzed Mediterranean storms. In particular, the test shows high potential for delineating non-precipitating areas (more than 90% of successful cases for every considered cloud type and to identify precipitating ice clouds related to convective rain (confirmed by 82% of hits. On the other hand, the relative inability to address the stratiform cloud systems is proved by the fact that the majority of the missed cases, for each cloud types, is characterized by light

  12. Combined optical and electrical effects in ferroelectric crystal for high laser intensities

    Science.gov (United States)

    Kukhtarev, N. V.; Kukhtareva, T. V.; Stargell, G.; Wang, J. C.

    2009-08-01

    In this study, we have derived equations for the pyroelectric and photogalvanic contribution to the electrical charging of the photosensitive ferroelectric crystal. Standard photorefractive equations are supplemented by the equation of state for the polarization density following the Devonshire-Ginsburg-Landau (DGL) approach. The photogalvanic voltage and current is considered for a wide intensity range, which includes the CW and the pulsed photo-excitation with high intensities when the impurity is fully ionized and when the traditional linear-recombination approach is not valid. The crystal electrostatic accelerators, based on charging of ferroelectric crystals by pyroelectric and photogalvanic effects, are discussed in relation to the generation of the self-focused electron beam, X-rays, and neutrons.

  13. Wavenumber Processing Techniques to Determine Structural Intensity and Its Divergence from Optical Measurements without Leakage Effects

    Directory of Open Access Journals (Sweden)

    Jean-Claude Pascal

    2002-01-01

    Full Text Available The technique of processing data in the wavenumber domain based on the Spatial Fourier Transform (SFT, is a powerful tool to compute higher-order partial derivatives occurred in the expressions of the structural intensity and its divergence. However, performing directly the SFT usually results in great distortions if a discontinuity occurs in spatial periodicity (leakage effect. The worst thing is that the divergence of a free plate cannot correctly be estimated by existing wavenumber processing such as the STF and zero padding method. In this paper, a new algorithm -- mirror processing, is developed. By the use of vibrating velocity measured from the technique of laser scanning vibrometry, the structural intensity, its divergence and the force distribution are evaluated by different techniques of wavenumber processing. It is shown that the distortions caused by leakage effects can be removed by using advanced algorithms.

  14. Capacity Bounds and High-SNR Capacity of MIMO Intensity-Modulation Optical Channels

    KAUST Repository

    Chaaban, Anas

    2018-02-19

    The capacity of the intensity modulation direct detection multiple-input multiple-output channel is studied. Therein, the nonnegativity constraint of the transmit signal limits the applicability of classical schemes, including precoding. Thus, new ways are required for deriving capacity bounds for this channel. To this end, capacity lower bounds are developed in this paper by deriving the achievable rates of two precodingfree schemes: Channel inversion and QR decomposition. The achievable rate of a DC-offset SVD-based scheme is also derived as a benchmark. Then, capacity upper bounds are derived and compared against the lower bounds. As a result, the capacity at high signal-to-noise ratio (SNR) is characterized for the case where the number of transmit apertures is not larger than the number of receive apertures, and is shown to be achievable by the QR decomposition scheme. This is shown for a channel with average intensity or peak intensity constraints. Under both constraints, the high-SNR capacity is approximated within a small gap. Extensions to a channel with more transmit apertures than receive apertures are discussed, and capacity bounds for this case are derived.

  15. Asymmetry of magneto-optical Kerr effect loops of Co nano-columns grown by oblique incident angle deposition

    International Nuclear Information System (INIS)

    Tang, F.; Liu, D.-L.; Ye, D.-X.; Lu, T.-M.; Wang, G.-C.

    2004-01-01

    Magneto-optical Kerr effect (MOKE) in the longitudinal mode was used to measure the in-plane magnetic anisotropy of about 300nm thick Co nano-column films that were grown by e-beam evaporation at different oblique incident angles (0-85 o ) on native SiO 2 substrates at room temperature. The symmetry of MOKE loops measured at azimuthal angles that are 180 o apart is obviously broken for Co nano-column films grown at high deposition angles >70 o . The plot of coercivity H c of loops versus azimuthal angle shows that H c values for azimuthal angles between -90 o and 90 o are much larger than the values for azimuthal angles between 90 o and 270 o . The asymmetry of coercivity is due to MOKE measurement that combines both longitudinal and polar Kerr effects. This combination is caused by the oblique magnetic anisotropy associated with the tilted Co nano-columns. A method is introduced to separate the longitudinal and polar Kerr effects. The longitudinal Kerr effect is obtained by adding hysteresis loops measured at azimuthal angles 180 o apart while the polar Kerr effect is obtained by subtracting these two loops. By comparing these two orthogonal magnetization components represented by longitudinal and polar Kerr effects, we show that magnetization rotation exists in the magnetic reversal process even at azimuthal angle φ=0 o that is the closest in-plane direction to the easy axis. After separating these two Kerr effects, the two-fold symmetry of coervicity associated with tilted nano-columns measured by longitudinal Kerr effect is restored

  16. The Combination of SAT and SBT Protocols May Help Reduce the Incidence of Ventilator-Associated Pneumonia in the Burn Intensive Care Unit.

    Science.gov (United States)

    Lee, Yann-Leei Larry; Sims, Kaci D; Butts, Charles C; Frotan, M Amin; Kahn, Steven; Brevard, Sidney B; Simmons, Jon D

    There are few published reports on the unique nature of burn patients using a paired spontaneous awakening and spontaneous breathing protocol. A combined protocol was implemented in our burn intensive care unit (ICU) on January 1, 2012. This study evaluates the impact of this protocol on patient outcomes in a burn ICU. We performed a retrospective review of our burn registry over 4 years, including all patients placed on mechanical ventilation. In the latter 2 years, patients meeting criteria underwent daily spontaneous awakening trial; if successful, spontaneous breathing trial was performed. Patient data included age, burn size, percent full-thickness burn, tracheostomy, and inhalation injury. Outcome measures included ventilator days, ICU and hospital lengths of stay, pneumonia, and disposition. Data were analyzed using Graphpad Prism and IBM SPSS software, with statistical significance defined as P < .05. There were 171 admissions in the preprotocol period and 136 after protocol implementation. Protocol patients had greater percent full-thickness burns, but did not differ in other characteristics. The protocol group had significantly shorter ICU length of stay, fewer ventilator days, and lower pneumonia incidence. Hospital length of stay, disposition, and mortality were not significantly different. Among patients with inhalation injuries, the protocol group exhibited fewer ventilator and ICU days. Protocol implementation in a burn ICU was accompanied by decreased ventilator days and a reduced incidence of pneumonia. A combined spontaneous awakening and breathing protocol is safe and may improve clinical practice in the burn ICU.

  17. Incidence and Determinants of Health Care-Associated Blood Stream Infection at a Neonatal Intensive Care Unit in Ujjain, India: A Prospective Cohort Study

    Directory of Open Access Journals (Sweden)

    Mamta Dhaneria

    2018-01-01

    Full Text Available Very little is known about laboratory-confirmed blood stream infections (LCBIs in neonatal intensive care units (NICUs in resource-limited settings. The aim of this cohort study was to determine the incidence, risk factors, and causative agents of LCBIs in a level-2 NICU in India. The diagnosis of LCBIs was established using the Centre for Disease Control, USA criteria. A predesigned questionnaire containing risk factors associated with LCBIs was filled-in. A total of 150 neonates (43% preterm were included in the study. The overall incidence of LCBIs was 31%. The independent risk factors for LCBIs were: preterm neonates (relative risk (RR 2.23, duration of NICU stay more than 14 days (RR 1.75, chorioamnionitis in the mother (RR 3.18, premature rupture of membrane in mothers (RR 2.32, neonate born through meconium-stained amniotic fluid (RR 2.32, malpresentation (RR 3.05, endotracheal intubation (RR 3.41, umbilical catheterization (RR 4.18, and ventilator-associated pneumonia (RR 3.17. The initiation of minimal enteral nutrition was protective from LCBIs (RR 0.22. The predominant causative organisms were gram-negative pathogens (58%. The results of the present study can be used to design and implement antibiotic stewardship policy and introduce interventions to reduce LCBIs in resource-limited settings.

  18. Predicting Antimicrobial Resistance Prevalence and Incidence from Indicators of Antimicrobial Use: What Is the Most Accurate Indicator for Surveillance in Intensive Care Units?

    Directory of Open Access Journals (Sweden)

    Élise Fortin

    Full Text Available The optimal way to measure antimicrobial use in hospital populations, as a complement to surveillance of resistance is still unclear. Using respiratory isolates and antimicrobial prescriptions of nine intensive care units (ICUs, this study aimed to identify the indicator of antimicrobial use that predicted prevalence and incidence rates of resistance with the best accuracy.Retrospective cohort study including all patients admitted to three neonatal (NICU, two pediatric (PICU and four adult ICUs between April 2006 and March 2010. Ten different resistance/antimicrobial use combinations were studied. After adjustment for ICU type, indicators of antimicrobial use were successively tested in regression models, to predict resistance prevalence and incidence rates, per 4-week time period, per ICU. Binomial regression and Poisson regression were used to model prevalence and incidence rates, respectively. Multiplicative and additive models were tested, as well as no time lag and a one 4-week-period time lag. For each model, the mean absolute error (MAE in prediction of resistance was computed. The most accurate indicator was compared to other indicators using t-tests.Results for all indicators were equivalent, except for 1/20 scenarios studied. In this scenario, where prevalence of carbapenem-resistant Pseudomonas sp. was predicted with carbapenem use, recommended daily doses per 100 admissions were less accurate than courses per 100 patient-days (p = 0.0006.A single best indicator to predict antimicrobial resistance might not exist. Feasibility considerations such as ease of computation or potential external comparisons could be decisive in the choice of an indicator for surveillance of healthcare antimicrobial use.

  19. Excitation of Nuclei and Atoms Trapping in Optical Fields of High Intensity

    Science.gov (United States)

    2006-11-01

    produces the error signal, is fed to this solenoid . Therefore, the laser frequency is not modulated and the laser line is not broadened. The frequency... laser intensity I~1016W/cm2 to a few MeV at I~1019W/cm2, different nuclear processes can be initiated in the plasma and surrounding media: fusion ...makes use of excited nuclei as an amplifying medium. The most likely medium for gamma-ray lasers is an ensemble of metastable nuclear isomers

  20. All-optical intensity modulation based on graphene-coated microfibre waveguides

    Science.gov (United States)

    Wang, Ruiduo; Li, Diao; Jiang, Man; Wu, Hao; Xu, Xiang; Ren, Zhaoyu

    2018-03-01

    We investigate graphene-covered microfibre (GCM) waveguides, and analyse the microfibres' evanescent field distributions in different diameters and lengths by numerically simulation. According to the simulation results, we designed a graphene-based all-optical modulator using 980 nm and Amplified Spontaneous Emission (ASE) lasers, employing the microfibre's evanescent field induced light-graphene interaction. We studied the modulation effect that is influenced by the microfibre's diameter, number of graphene layers, and effective graphene length. Compared to a single graphene layer of shorter length, the double graphene layer with longer length presents stronger absorption and higher modulation depth. Using a 2- μm diameter microfibre covered by ∼0.3 cm double graphene sheets, we achieved a modulation depth of 8.45 dB. This modulator features ease of fabrication, low cost, and a controllable modulation depth.

  1. Intense source of spin-polarized electrons using laser-induced optical pumping

    International Nuclear Information System (INIS)

    Gray, L.G.; Giberson, K.W.; Cheng, C.; Keiffer, R.S.; Dunning, F.B.; Walters, G.K.

    1983-01-01

    A source of spin-polarized electrons based on a laser-pumped flowing helium afterglow is described. He(2 3 S) atoms contained in the afterglow are optically pumped using circularly polarized 1.08-μm (2 3 S→2 3 P) radiation provided by a NaF (F 2+ )( color-center laser. Spin angular momentum conservation in subsequent chemi-ionization reactions with CO 2 produces polarized electrons that are extracted from the afterglow. At low currents, < or approx. =1 μA, polarizations of approx.70%--80% are achieved. At higher currents the polarization decreases, falling to approx.40% at 50 μA. The spin polarization can be simply reversed (P→-P) and the source is suitable for use in the majority of low-energy spin-dependent scattering experiments proposed to date

  2. New optical scheme of the intensity control for a remote gas analyzer

    Science.gov (United States)

    Shabrov, Denis V.; Gorobets, Vadim A.; Puchkouski, Ilya N.; Kuntsevich, Boris F.

    2017-10-01

    The new scheme of the reference channel of a remote gas analyzer has been offered and realized. The use of additional reflective elements with the low reflection factor allows to receive full interception of laser radiation and to provide a linear operating mode of a photodetector even for the strongest laser lines. At the measurement of a concentration of air pollutions on a differential method the weak dependence of reflection factors for used reflecting plates from wavelength can be easy to take into account by adding corresponding factors in the formula for calculations of air pollution concentrations. The application of the new optical scheme of the reference channel for the gas analyzer and the addition new correcting temperature constants in the calculations has allowed carrying out correct measurements of air pollutants with the high accuracy.

  3. High-power optics lasers and applications

    CERN Document Server

    Apollonov, Victor V

    2015-01-01

    This book covers the basics, realization and materials for high power laser systems and high power radiation interaction with  matter. The physical and technical fundamentals of high intensity laser optics and adaptive optics and the related physical processes in high intensity laser systems are explained. A main question discussed is: What is power optics? In what way is it different from ordinary optics widely used in cameras, motion-picture projectors, i.e., for everyday use? An undesirable consequence of the thermal deformation of optical elements and surfaces was discovered during studies of the interaction with powerful incident laser radiation. The requirements to the fabrication, performance and quality of optical elements employed within systems for most practical applications are also covered. The high-power laser performance is generally governed by the following: (i) the absorption of incident optical radiation (governed primarily by various absorption mechanisms), (ii) followed by a temperature ...

  4. Graphics processing unit accelerated intensity-based optical coherence tomography angiography using differential frames with real-time motion correction.

    Science.gov (United States)

    Watanabe, Yuuki; Takahashi, Yuhei; Numazawa, Hiroshi

    2014-02-01

    We demonstrate intensity-based optical coherence tomography (OCT) angiography using the squared difference of two sequential frames with bulk-tissue-motion (BTM) correction. This motion correction was performed by minimization of the sum of the pixel values using axial- and lateral-pixel-shifted structural OCT images. We extract the BTM-corrected image from a total of 25 calculated OCT angiographic images. Image processing was accelerated by a graphics processing unit (GPU) with many stream processors to optimize the parallel processing procedure. The GPU processing rate was faster than that of a line scan camera (46.9 kHz). Our OCT system provides the means of displaying structural OCT images and BTM-corrected OCT angiographic images in real time.

  5. CROSS-CORRELATION BETWEEN X-RAY AND OPTICAL/NEAR-INFRARED BACKGROUND INTENSITY FLUCTUATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell-Wynne, Ketron; Cooray, Asantha [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Xue, Yongquan [CAS Key Laboratory for Researches in Galaxies and Cosmology, Center for Astrophysics, Department of Astronomy, University of Science and Technology of China, Chinese Academy of Sciences, Hefei, Anhui 230026 (China); Luo, Bin [School of Astronomy and Space Science, Nanjing University, Nanjing, 210093 (China); Brandt, William [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA, 16802 (United States); Koekemoer, Anton [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2016-12-01

    Angular power spectra of optical and infrared background anisotropies at wavelengths between 0.5 and 5 μ m are a useful probe of faint sources present during reionization, in addition to faint galaxies and diffuse signals at low redshift. The cross-correlation of these fluctuations with backgrounds at other wavelengths can be used to separate some of these signals. A previous study on the cross-correlation between X-ray and Spitzer fluctuations at 3.6 μ m and 4.5 μ m has been interpreted as evidence for direct collapse black holes present at z  > 12. Here we return to this cross-correlation and study its wavelength dependence from 0.5 to 4.5 μ m using Hubble and Spitzer data in combination with a subset of the 4 Ms Chandra observations in GOODS-S/ECDFS. Our study involves five Hubble bands at 0.6, 0.7, 0.85, 1.25, and 1.6 μ m, and two Spitzer -IRAC bands at 3.6 μ m and 4.5 μ m. We confirm the previously seen cross-correlation between 3.6 μ m (4.5 μ m) and X-rays with 3.7 σ (4.2 σ ) and 2.7 σ (3.7 σ ) detections in the soft [0.5–2] keV and hard [2–8] keV X-ray bands, respectively, at angular scales above 20 arcsec. The cross-correlation of X-rays with Hubble is largely anticorrelated, ranging between the levels of 1.4 σ –3.5 σ for all the Hubble and X-ray bands. This lack of correlation in the shorter optical/NIR bands implies the sources responsible for the cosmic infrared background at 3.6 and 4.5 μ m are at least partly dissimilar to those at 1.6 μ m and shorter.

  6. Pre-resonance enhancement of exceptional intensity in Aggregation-Induced Raman Optical Activity (AIROA) spectra of lutein derivatives

    Science.gov (United States)

    Zajac, G.; Lasota, J.; Dudek, M.; Kaczor, A.; Baranska, M.

    2017-02-01

    Recently reported new phenomenon of Aggregation-Induced Raman Optical Activity is demonstrated here for the first time in the pre-resonance conditions for lutein diacetate and 3‧-epi-lutein supramolecular self-assembles. We demonstrate that minor alterations in the lutein structure (e.g. acetylation of hydroxyl groups or different configuration at one of the chiral center) can lead to definitely different spectral profiles and optical properties due to formation of aggregates of different structure and type. Lutein forms only H-aggregates, lutein diacetate only J-aggregates, while 3‧-epi-lutein can occur in both forms simultaneously. Variety of aggregates' structures is so large that not only the type of aggregation is different, but also their chirality. It is remarkable that even in the pre-resonance conditions, aggregation of lutein derivatives can lead to the intense ROA signal, and moreover, 3‧-epi-lutein demonstrated the highest resonance ROA CID ratio that has ever been reported.

  7. Characterization of the phase modulation property of a free-space electro-optic modulator by interframe intensity correlation matrix.

    Science.gov (United States)

    Yue, Huimin; Song, Lei; Hu, Zexiong; Liu, Hongxiang; Liu, Yong; Liu, Yongzhi; Peng, Zengshou

    2012-07-01

    Characterization of a phase modulator or phase shifter has always been an integral part of phase-modulating or phase-adjusting applications. We propose a simplified approach to characterize a phase modulator by investigating the performance of phase shifts from grabbed interferograms using the phase extraction method. After reviewing some phase analysis techniques, the interframe intensity correlation (IIC) matrix method is introduced to the investigation. The proposed strategy is illustrated by the measurement of a free-space electro-optic modulator (EOM). Placing the modulator in one arm of a Michelson interferometer, the global phase shifts are estimated by the IIC method from the phase-stepped interferograms. Experimental results demonstrate the tested EOM has a phase modulation response of at least 2π  rad with a π/20  rad modulation precision for λ=1064  nm. In addition, our method is applicable to various types of phase modulator or phase shifter calibration, e.g., electro-optic phase modulator, spatial light modulator, or piezoelectric transducer (PZT).

  8. Investigation of optical and radiative properties of aerosols during an intense dust storm: A regional climate modeling approach

    Science.gov (United States)

    Bran, Sherin Hassan; Jose, Subin; Srivastava, Rohit

    2018-03-01

    The dynamical and optical properties of aerosols during an intense dust storm event over the Arabian Sea have been studied using Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) and space borne instruments such as MODIS, MISR, CALIPSO and CERES during the period 17 to 24 March, 2012. The model captures the spatio-temporal and vertical variations of meteorological and optical parameters, however an overestimation in simulated aerosol optical parameters are observed when compared to satellite retrievals. The correlation coefficients (R) between simulated and observed AOD from MODIS and MISR are found to be 0.54 and 0.32 respectively. Model simulated AOD on dusty days (20 and 21 March 2012) increased by 2-3 times compared to non-dusty days (17 and 24 March 2012) and the single scattering albedo (SSA) and the asymmetry parameter increased from 0.96 to 0.99 and from 0.56 to 0.66, respectively. The R between simulated shortwave (SW) radiation at top of the atmosphere (TOA) and TOA SW radiation obtained from CERES is found to be 0.43, however the model simulated SW radiation at the TOA showed an underestimation with respect to CERES. The shortwave aerosol radiative forcing (SWARF) during the event over surface and TOA are ∼ -19.3 and ∼ -14.2 Wm-2 respectively, which is about 2-5 times higher when compared to the respective forcing values during non-dust days. Estimated net radiative forcing was in the range of -13 to -21 Wm-2 at TOA and -12 to -20 Wm-2 at the surface. The heating rate during event days within the lower atmosphere near 850 hPa is found to 0.32 - 0.4 K day-1 and 0.18 - 0.22 K day-1 on dusty and non-dusty days, respectively. Results of this study may be useful for a better modeling of atmospheric aerosols and its optical and radiative properties over oceanic region.

  9. Influence of ionizing radiation on optical hardness of transparent dielectrics to action of huge intensity laser light

    International Nuclear Information System (INIS)

    Bedilov, M.R.; Khalilov, R.A.

    2006-01-01

    Full text: This paper presents results of researches of optical hardness of γ -irradiated with doze 10 4 - 10 9 rad alkali-silicate (K, GLS, LGS) and quartz (KU, KV, KSG) glasses against influence of radiation neodymium laser with intensity q = 0,1-1000 GWt/cm 2 . It is observed, that the laser produces damage of surface and volume of investigated glasses before and after γ-irradiation. This damage has threshold character and is always accompanied by a bright luminescence of plasma. Definition of threshold values of intensity superficial q s and volumetric q d laser produced damage was made by the complex method - fixing the moment of damage of transparent dielectric by simultaneous registration of the laser impulse which has passed through plasma of breakdown, mass-charge spectrum of ions of plasma and measuring the energy falling on the glass, and of penetrated and mirror-image radiations; and by optical microscopy. This method of research of influence γ-induced in transparent dielectric radiating defects on its optical stability against influence of laser radiation allows not only to define values q s and q d in the investigated interval of dozes, but also to investigate in details physical phenomena taking place in this process of interaction. On the basis of the received data quantitative characteristics of optical durability of the investigated glasses on wave length of λ1,06 microns depending on dozes of γ-irradiation and intensity of laser radiation are made. Doze dependences of charge and power spectra and quantitative characteristics of ions of plasma of breakdown were investigated at q≥ q s . In the investigated interval of dozes of γ- irradiation and intensity of laser radiation by a method of optical microscopy the morphology of occurring laser damage as surfaces, and volume of glass is also studied. It is found, that γ -induced defects in investigated glasses strongly effect on thresholds of damage q s and q d and on characteristics of ions

  10. Nosocomial infections in the intensive care unit: Incidence, risk factors, outcome and associated pathogens in a public tertiary teaching hospital of Eastern India.

    Science.gov (United States)

    Dasgupta, Sugata; Das, Soumi; Chawan, Neeraj S; Hazra, Avijit

    2015-01-01

    The increased morbidity and mortality associated with nosocomial infections in the intensive care unit (ICU) is a matter of serious concern today. To determine the incidence of nosocomial infections acquired in the ICU, their risk factors, the causative pathogens and the outcome in a tertiary care teaching hospital. This was a prospective observational study conducted in a 12 bedded combined medical and surgical ICU of a medical college hospital. The study group comprised 242 patients admitted for more than 48 h in the ICU. Data were collected regarding severity of the illness, primary reason for ICU admission, presence of risk factors, presence of infection, infecting agent, length of ICU and hospital stay, and survival status and logistic regression analysis was done. The nosocomial infection rate was 11.98% (95% confidence interval 7.89-16.07%). Pneumonia was the most frequently detected infection (62.07%), followed by urinary tract infections and central venous catheter associated bloodstream infections. Prior antimicrobial therapy, urinary catheterization and length of ICU stay were found to be statistically significant risk factors associated with nosocomial infection. Nosocomial infection resulted in a statistically significant increase in length of ICU and hospital stay, but not in mortality. Nosocomial infections increase morbidity of hospitalized patients. These findings can be utilized for planning nosocomial infection surveillance program in our setting.

  11. Optimization of the Laser Hardening Process by Adapting the Intensity Distribution to Generate a Top-hat Temperature Distribution Using Freeform Optics

    Directory of Open Access Journals (Sweden)

    Fritz Klocke

    2017-06-01

    Full Text Available Laser hardening is a surface hardening process which enables high quality results due to the controllability of the energy input. The hardened area is determined by the heat distribution caused by the intensity profile of the laser beam. However, commonly used top-hat laser beams do not provide an ideal temperature profile. Therefore, in this paper the beam profile, and thus the temperature profile, is optimized using freeform optics. The intensity distribution is modified to generate a top-hat temperature profile on the surface. The results of laser hardening with the optimized distribution are thereupon compared with results using a top-hat intensity distribution.

  12. Aerosol optical, microphysical and radiative forcing properties during variable intensity African dust events in the Iberian Peninsula

    Science.gov (United States)

    Fernández, A. J.; Molero, F.; Salvador, P.; Revuelta, A.; Becerril-Valle, M.; Gómez-Moreno, F. J.; Artíñano, B.; Pujadas, M.

    2017-11-01

    Aerosol measurements at two AERONET (AErosol RObotic NETwork) sites of the Iberian Peninsula: Madrid (40°.45N, 3.72W) and La Coruña (43°.36N, 8°.42W) have been analyzed for the period 2012-2015 to assess aerosol optical properties (intensive and extensive) throughout the atmospheric column and their radiative forcing (RF) and radiative forcing efficiency (RFeff) estimates at the Bottom and Top Of Atmosphere (BOA and TOA respectively). Specific conditions as dust-free and African dust have been considered for the study. Unprecedented, this work uses the quantification of the African dust aerosol at ground level which allows us to study such AERONET products at different intensity levels of African events: Low (L), High (H) and very high (VH). The statistical difference between dust-free and African dust conditions on the aforementioned parameters, quantified by means of the non-parametric Kolmogorov-Smirnov test, is quite clear in Madrid, however it is not in La Coruña. Scattering Angstrom Exponent (SAE) and Absorption Angstrom Exponent (AAE) were found to be 1.64 ± 0.29 and 1.14 ± 0.23 respectively in Madrid for dust-free conditions because typical aerosol sources are traffic emissions and residential heating, and black carbon is an important compound in this aerosol kind. On the other hand, SAE and AAE were 0.96 ± 0.60 and 1.44 ± 0.51 for African dust conditions in this location. RF (at shortwave radiation) seems to decrease as the African dust contribution at ground level is larger which indicates the cooling effect of African dust aerosol in Madrid. We have also proved the potential of a 2D-cluster analysis based on AAE and SAE to differentiate both situations in Madrid. Conversely, it is suggested that aerosols observed in La Coruña under dust-free conditions might come from different sources. Then, SAE and AAE are not good enough indicators to distinguish between dust-free and African dust conditions. Besides, as La Coruña is at a further distance

  13. Experimental investigation of saturation effect on pump-to-signal intensity modulation transfer in single-pump phase-insensitive fiber optic parametric amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke

    2013-01-01

    We present an experimental characterization of how signal gain saturation affects the transfer of intensity modulation from the pump to the signal in single-pump, phase-insensitive fiber optic parametric amplifiers (FOPAs). In this work, we demonstrate experimentally for the first time, to our...

  14. A systematics of optical model compound nucleus formation cross sections for neutrons, proton, deuteron, 3He and alpha particle incidents

    International Nuclear Information System (INIS)

    Murata, Toru

    2000-01-01

    Simple formulae to reproduce the optical model compound nucleus formation cross sections for neutron, proton, deuteron, triton, 3 He and alpha particles are presented for target nuclei of light to medium weight mass region. (author)

  15. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  16. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  17. Incidence, morbidity, and mortality of contrast-induced acute kidney injury in a surgical intensive care unit: a prospective cohort study.

    Science.gov (United States)

    Valette, Xavier; Parienti, Jean-Jacques; Plaud, Benoit; Lehoux, Philippe; Samba, Désiré; Hanouz, Jean-Luc

    2012-06-01

    Data on contrast-induced acute kidney injury (CI-AKI) in intensive care unit (ICU) are scarce and controversial. The objectives of the study were to evaluate the incidence and characteristics of CI-AKI in a surgical ICU. We conducted a 13-month prospective observational study. Three definitions were compared to characterize CI-AKI: Barrett and Parfrey criteria; Risk of renal dysfunction, Injury to the kidney, Failure of kidney function, Loss of kidney function and End stage renal disease (RIFLE) classification; and Acute Kidney Injury Network (AKIN) criteria. Patients hospitalized in surgical ICU who had received an injection of contrast medium, who were not on renal replacement therapy, who had stable serum creatinine before injection, and no other etiology for new acute kidney injury were included. One hundred one patients were included. The frequency of CI-AKI was 17%, 19%, and 19% according to Barrett and Parfrey criteria; RIFLE classification; and AKIN criteria, respectively. Diabetes mellitus, creatinine clearance less than 60 mL/min, and concomitant aminoglycoside administration were associated with CI-AKI. Statistically significant associations were found between CI-AKI and renal replacement therapy with all 3 definitions and between CI-AKI and mortality when AKIN criteria were used. These results show that CI-AKI is not inconsequential in critically ill patients. In the present study, AKIN criteria appear to be most relevant to define CI-AKI. Further studies are required to explore CI-AKI prevention in ICU. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  19. Damage thresholds for blaze diffraction gratings and grazing incidence optics at an X-ray free-electron laser.

    Science.gov (United States)

    Krzywinski, Jacek; Conley, Raymond; Moeller, Stefan; Gwalt, Grzegorz; Siewert, Frank; Waberski, Christoph; Zeschke, Thomas; Cocco, Daniele

    2018-01-01

    The Linac Coherent Light Source is upgrading its machine to high repetition rate and to extended ranges. Novel coatings, with limited surface oxidation, which are able to work at the carbon edge, are required. In addition, high-resolution soft X-ray monochromators become necessary. One of the big challenges is to design the mirror geometry and the grating profile to have high reflectivity (or efficiency) and at the same time survive the high peak energy of the free-electron laser pulses. For these reasons the experimental damage threshold, at 900 eV, of two platinum-coated gratings with different blazed angles has been investigated. The gratings were tested at 1° grazing incidence. To validate a model for which the damage threshold on the blaze grating can be estimated by calculating the damage threshold of a mirror with an angle of incidence identical to the angle of incidence on the grating plus the blaze angle, tests on Pt-coated substrates have also been performed. The results confirmed the prediction. Uncoated silicon, platinum and SiB 3 (both deposited on a silicon substrate) were also investigated. In general, the measured damage threshold at grazing incidence is higher than that calculated under the assumption that there is no energy transport from the volume where the photons are absorbed. However, it was found that, for the case of the SiB 3 coating, the grazing incidence condition did not increase the damage threshold, indicating that the energy transport away from the extinction volume is negligible.

  20. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    International Nuclear Information System (INIS)

    Ungan, F.; Restrepo, R.L.; Mora-Ramos, M.E.; Morales, A.L.; Duque, C.A.

    2014-01-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga 0.7 Al 0.3 As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga 0.7 Al 0.3 As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications

  1. Finite-Difference Time-Domain Integration of Ultrafast Dynamics in Optical Resonators

    National Research Council Canada - National Science Library

    Basinger, Scott

    1993-01-01

    .... The resonator is a Fabry-Perot cavity that has a nonlinear absorbing material in the center. When an optical field of the resonant frequency is incident upon the cavity, the field intensity increases inside the cavity...

  2. Measuring high-frequency responses of an electro-optic phase modulator based on dispersion induced phase modulation to intensity modulation conversion

    Science.gov (United States)

    Zhang, Shangjian; Wang, Heng; Wang, Yani; Zou, Xinhai; Zhang, Yali; Liu, Shuang; Liu, Yong

    2014-11-01

    We investigate the phase modulation to intensity modulation conversion in dispersive fibers for measuring frequency responses of electro-optic phase modulators, and demonstrate two typical measurements with cascade path and fold-back path. The measured results achieve an uncertainty of less than 2.8% within 20 GHz. Our measurements show stable and repeatable results because the optical carrier and its phase-modulated sidebands are affected by the same fiber impairments. The proposed method requires only dispersive fibers and works without any small-signal assumption, which is applicable for swept frequency measurement at different driving levels and operating wavelengths.

  3. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  4. Testing of Sapphire Optical Fiber and Sensors in Intense Radiation Fields When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States)

    2017-12-15

    The primary objective of this project was to determine the optical attenuation and signal degradation of sapphire optical fibers & sensors (temperature & strain), in-situ, operating at temperatures up to 1500°C during reactor irradiation through experiments and modeling. The results will determine the feasibility of extending sapphire optical fiber-based instrumentation to extremely high temperature radiation environments. This research will pave the way for future testing of sapphire optical fibers and fiber-based sensors under conditions expected in advanced high temperature reactors.

  5. Relaxed damage threshold intensity conditions and nonlinear increase in the conversion efficiency of an optical parametric oscillator using a bi-directional pump geometry.

    Science.gov (United States)

    Norris, G; McConnell, G

    2010-03-01

    A novel bi-directional pump geometry that nonlinearly increases the nonlinear optical conversion efficiency of a synchronously pumped optical parametric oscillator (OPO) is reported. This bi-directional pumping method synchronizes the circulating signal pulse with two counter-propagating pump pulses within a linear OPO resonator. Through this pump scheme, an increase in nonlinear optical conversion efficiency of 22% was achieved at the signal wavelength, corresponding to a 95% overall increase in average power. Given an almost unchanged measured pulse duration of 260 fs under optimal performance conditions, this related to a signal wavelength peak power output of 18.8 kW, compared with 10 kW using the traditional single-pass geometry. In this study, a total effective peak intensity pump-field of 7.11 GW/cm(2) (corresponding to 3.55 GW/cm(2) from each pump beam) was applied to a 3 mm long periodically poled lithium niobate crystal, which had a damage threshold intensity of 4 GW/cm(2), without impairing crystal integrity. We therefore prove the application of this novel pump geometry provides opportunities for power-scaling of synchronously pumped OPO systems together with enhanced nonlinear conversion efficiency through relaxed damage threshold intensity conditions.

  6. Inspection of 56Fe γ-Ray angular distributions as a function of incident neutron energy using optical model approaches

    Directory of Open Access Journals (Sweden)

    Vanhoy J.R.

    2017-01-01

    Full Text Available Neutron inelastic scattering cross sections measured directly through (n,n or deduced from γ-ray production cross sections following inelastic neutron scattering (n,n′γ are a focus of basic and applied research at the University of Kentucky Accelerator Laboratory (www.pa.uky.edu/accelerator. For nuclear data applications, angle-integrated cross sections are desired over a wide range of fast neutron energies. Several days of experimental beam time are required for a data set at each incident neutron energy, which limits the number of angular distributions that can be measured in a reasonable amount of time. Approximations can be employed to generate cross sections with a higher energy resolution, since at 125o, the a2P2 term of the Legendre expansion is identically zero and the a4P4 is assumed to be very small. Provided this assumption is true, a single measurement at 125o would produce the γ-ray production cross section. This project tests these assumptions and energy dependences using the codes CINDY/SCAT and TALYS/ECIS06/SCAT. It is found that care must be taken when interpreting γ-ray excitation functions as cross sections when the incident neutron energy is < 1000 keV above threshold or before the onset of feeding.

  7. Inspection of 56Fe γ-Ray angular distributions as a function of incident neutron energy using optical model approaches

    Science.gov (United States)

    Vanhoy, J. R.; Ramirez, A. P.; Alcorn-Dominguez, D. K.; Hicks, S. F.; Peters, E. E.; McEllistrem, M. T.; Mukhopadhyay, S.; Yates, S. W.

    2017-09-01

    Neutron inelastic scattering cross sections measured directly through (n,n) or deduced from γ-ray production cross sections following inelastic neutron scattering (n,n'γ) are a focus of basic and applied research at the University of Kentucky Accelerator Laboratory (www.pa.uky.edu/accelerator). For nuclear data applications, angle-integrated cross sections are desired over a wide range of fast neutron energies. Several days of experimental beam time are required for a data set at each incident neutron energy, which limits the number of angular distributions that can be measured in a reasonable amount of time. Approximations can be employed to generate cross sections with a higher energy resolution, since at 125o, the a2P2 term of the Legendre expansion is identically zero and the a4P4 is assumed to be very small. Provided this assumption is true, a single measurement at 125o would produce the γ-ray production cross section. This project tests these assumptions and energy dependences using the codes CINDY/SCAT and TALYS/ECIS06/SCAT. It is found that care must be taken when interpreting γ-ray excitation functions as cross sections when the incident neutron energy is < 1000 keV above threshold or before the onset of feeding.

  8. Analysis of mesoporous thin films by X-ray reflectivity, optical reflectivity and grazing incidence small angle X-ray scattering

    International Nuclear Information System (INIS)

    Gibaud, A.; Dourdain, S.; Vignaud, G.

    2006-01-01

    It is well-established that X-ray reflectivity (XR) is an invaluable tool to investigate the structure of thin films. Indeed, this technique provides under correct analysis, the electron density profile of thin films in the direction perpendicular to the substrate. For thin films that exhibit lateral ordering at the nanometer scale, grazing incidence small angle X-ray scattering (GISAXS) ideally complements the XR technique to measure the scattering in off-specular directions. As typical examples, XR and GISAXS data of mesoporous silica thin films and porous materials are presented. The analysis of the XR curve allows to determine the porosity of the film. We also show that the combination of X-ray and visible optical reflection provides information about the index of refraction of thin films. Finally we report how capillary condensation of water can be monitored by XR and GISAXS

  9. Effect of low dose of intrathecal pethidine on the incidence and intensity of shivering during cesarean section under spinal anesthesia: a randomized, placebo-controlled, double-blind clinical trial.

    Science.gov (United States)

    Shami, Shoaleh; Nasseri, Karim; Shirmohammadi, Mousa; Sarshivi, Farzad; Ghadami, Negin; Ghaderi, Ebrahim; Pouladi, Mokhtar; Barzanji, Arvin

    2016-01-01

    Shivering is among the unpleasant and potentially harmful side effects of spinal anesthesia. The aim of this randomized double-blind clinical trial was to compare the antishivering effect of two different doses of intrathecal pethidine on the incidence and intensity of shivering and other side effects in patients who underwent cesarean section. In this study, 150 parturient females scheduled for nonemergent cesarean section were randomly allocated to three groups. Spinal anesthesia was performed with 0.5% hyperbaric bupivacaine (12.5 mg), plus 0.5 mL of 0.9% saline in the standard group (S group), and the same dose of bupivacaine with 5 mg (P5 group) or 10 mg of pethidine (P10 group). Demographic and surgical data, incidence and intensity of shivering (primary outcome), hemodynamic indices, forehead and core temperatures, maximum sensory level, Apgar scores, and adverse events were evaluated by a blinded observer. There were no significant differences between the three study groups regarding the demographic and surgical data, hemodynamic indices, core temperatures, and maximum sensory level ( P >0.05). The incidence and intensity of shivering were significantly less in the P5 and P10 groups ( P shivering during cesarean section, without having major side effects.

  10. Hot slumping glass technology for the grazing incidence optics of future missions with particular reference to IXO

    Science.gov (United States)

    Ghigo, M.; Basso, S.; Bavdaz, M.; Conconi, P.; Citterio, O.; Civitani, M.; Friedrich, P.; Gallieni, D.; Guldimann, B.; Martelli, F.; Negri, R.; Pagano, G.; Pareschi, G.; Parodi, G.; Proserpio, L.; Salmaso, B.; Scaglione, F.; Spiga, D.; Tagliaferri, G.; Terzi, L.; Tintori, M.; Vongehr, M.; Wille, E.; Winter, A.; Zambra, A.

    2010-07-01

    The mirrors of the International X-ray Observatory (IXO) consist of a large number of high quality segments delivering a spatial resolution better than 5 arcsec. A study concerning the slumping of thin glass foils for the IXO mirrors is under development in Europe, funded by ESA and led by the Brera Observatory. We are investigating two approaches, the "Direct" and "Indirect" slumping technologies, being respectively based on the use of convex and concave moulds. In the first case during the thermal cycle the optical surface of the glass is in direct contact with the mould surface, while in the second case it is the rear side of the foil which touches the master. Both approaches present pros and cons and aim of this study is also to make an assessment of both processes and to perform a trade-off between the two. The thin plates are made of D263glass produced by Schott. Each plate is 0.4 mm thick, with a reflecting area of 200 mm x 200 mm; the mould are made of Fused Silica. After the thermal cycle the slumped MPs are characterized to define their optical quality and microroughness. The adopted integration process foresees the bonding of the slumped foils to a rigid backplane by means of reinforcing ribs. During the bonding process the plates are constrained to stay in close contact to the surface of the master (i.e. the same mould used for the hot slumping process) by the application of a vacuum pump suction. In this way spring-back deformations and low frequency errors still present on the foil profile after slumping can be corrected. In this paper we present the preliminary results concerning achieved during the first part of the project.

  11. Young drivers who obtained their licence after an intensive driving course report more incidents than drivers with a traditional driver education.

    NARCIS (Netherlands)

    Craen, S. de & Vlakveld, W.P.

    2013-01-01

    This paper studies the effectiveness of intensive driving courses; both in driving test success and safe driving after passing the driving test. The so-called intensive driving course (IDC) consists of a limited number of consecutive days in which the learner driver takes driving lessons all day

  12. Study of intense pulse irradiation effects on silicon targets considered as ground matter for optical detectors; Etude des effets d`irradiations pulsees intenses sur des cibles de silicium considere en tant que materiau de base pour detecteurs optiques

    Energy Technology Data Exchange (ETDEWEB)

    Muller, O.

    1994-12-01

    This study aim was centered on morphological and structural alterations induced by laser irradiation on silicon targets considered as ground matter for optical detectors. First we recalled the main high light intensity effects on the condensed matter. Then we presented the experimental aspects. The experimental studies were achieved on two sample types: SiO{sub 2}/Si and Si. Two topics were studied: the defect chronology according to wavelength and pulse length, and the crystalline quality as well as the structure defects of irradiated zones by Raman spectroscopy. Finally, irradiation of Si targets by intense pulsed beams may lead to material fusion. This phenomenon is particularly easy when the material is absorbent, when the pulse is short and when the material is superficially oxidized. (MML). 204 refs., 93 figs., 21 tabs., 1 appendix.

  13. Extremely Intensive and Conservative Fault Capability Studies on Nuclear Facilities in Japan after the 2011 Tohoku Earthquake and Fukushima Daiichi Incident

    Science.gov (United States)

    Okumura, K.

    2013-12-01

    Rocks of the Japanese islands are mostly faulted since the Mesozoic Era. The opening of the Sea of Japan in Middle Miocene stretched most of the Japanese crust together with rifting systems. Modern compressional tectonic regime started in Pliocene and accelerated during Quaternary. The ubiquitous bedrock fault prior to the Quaternary had long been regarded as incapable for the future rupturing. This view on the bedrock fault, however, is in question after the March 11, 2011 Tohoku earthquake and tsunamis. There is no scientific reason for the Tohoku earthquake to let the geologists and seismologists worry about the capability of the long-deceased fault. Neither the unexpected April 11, 2011 extensional faulting event on shore in southern Fukushima prefecture has any scientific reason as well. There was no change and no new stress field, but the psychological situation of the scientists and the public welcomed the wrong belief in unexpected stress changes all over Japan, in the same manner that the March 11 M 9 was not expected. Finally, the capabilities of the bedrock faults, fractures, and joints came up to concern about seismic safety of nuclear facilities. After the incidents, the nuclear regulation authority of Japan began reevaluation of the seismic safety of all facilities in Japan. The primary issues of the reevaluation were conjunctive multi-fault mega-earthquakes and the capabilities of the bedrock faults, precisely reflecting the Tohoku events. The former does not require immediate abandonment of a facility. However, the latter now denies any chance of continued operation. It is because of the new (July 2013) safety guide gave top priority to the capability of the displacement under a facility for the evaluation on safe operation. The guide also requires utmost deterministic manner in very conservative ways. The regulators ordered the utility companies to thoroughly examine the capability for several sites, and started review of the studies in late 2012

  14. Radiative properties of optical board embedded with optical black holes

    International Nuclear Information System (INIS)

    Qiu, J.; Liu, L.H.; Hsu, P.-F.

    2011-01-01

    Unique radiative properties, such as wavelength-selective transmission or absorption, have been intensively studied. Historically, geometries for wavelength-selective of light absorption were developed based on metallic periodical structures, which were only applied in the case of TM wave incidence due to the excitation of surface plasmons. In this paper, we develop an alternative approach to selective wavelength of light absorption (both TE and TM waves), based on an optical board periodical embedded with optical black holes. Numerical work was carried out to study such structure's radiative properties within the wavelength range of 1-100 μm. The electromagnetic wave transmission through such a structure is predicted by solving Maxwell's equations using the finite-difference time-domain (FDTD) method. Spectral absorptance varies with the period of optical black holes. When the incidence wavelength is much larger than the inner core radius, most of the light energy will be transmitted through the inner core. Otherwise, the energy will be mainly absorbed. Numerical results of the radiative properties of the optical board with different incidence wavelengths are also obtained. The effect of the oblique incidence wave is investigated. This study helps us gain a better understanding of the radiative properties of an optical board embedded with optical black holes and develop an alternative approach to selective light absorption.

  15. Constellation-X to Generation-X: evolution of large collecting area moderate resolution grazing incidence x-ray telescopes to larger area high-resolution adjustable optics

    Science.gov (United States)

    Reid, Paul B.; Cameron, Robert A.; Cohen, Lester; Elvis, Martin; Gorenstein, Paul; Jerius, Diab; Petre, Robert; Podgorski, William A.; Schwartz, Daniel A.; Zhang, William W.

    2004-10-01

    Large collecting area x-ray telescopes are designed to study the early Universe, trace the evolution of black holes, stars and galaxies, study the chemical evolution of the Universe, and study matter in extreme environments. The Constellation-X mission (Con-X), planned for launch in 2016, will provide ~ 10^4 cm^2 collecting area with 15 arc-sec resolution, with a goal of 5 arc-sec. Future missions require larger collecting area and finer resolution. Generation-X (Gen-X), a NASA Visions Mission, will achieve 100 m^2 effective area at 1 keV and angular resolution of 0.1 arc-sec, half power diameter. We briefly describe the Con-X flowdown of imaging requirements to reflector figure error. To meet requirements beyond Con-X, Gen-X optics will be thinner and more accurately shaped than has ever been accomplished. To meet these challenging goals, we incorporate for the first time active figure control with grazing incidence optics. Piezoelectric material will be deposited in discrete cells directly on the back surface of the optical segments, with the strain directions oriented parallel to the surface. Differential strain between the two layers of the mirror causes localized bending in two directions, enabling local figure control. Adjusting figure on-orbit eases fabrication and metrology. The ability to make changes to mirror figure adds margin by mitigating risk due to launch-induced deformations and/or on-orbit degradation. We flowdown the Gen-X requirements to mirror figure and four telescope designs, and discuss various trades between the designs.

  16. Image correction in magneto-optical microscopy

    DEFF Research Database (Denmark)

    Paturi, P.; Larsen, B.H.; Jacobsen, B.A.

    2003-01-01

    An image-processing procedure that assures correct determination of the magnetic field distribution of magneto-optical images is presented. The method remedies image faults resulting from sources that are proportional to the incident light intensity, such as different types of defects...

  17. Incidência e fatores associados ao desmame simples, difícil e prolongado em uma unidade de terapia intensiva = Incidence and associated factors to simple, difficult and prolonged weaning in an intensive care unit

    Directory of Open Access Journals (Sweden)

    Fontela, Paula Caitano

    2016-01-01

    Full Text Available Introdução: A classificação do desmame ventilatório é uma ferramenta útil e importante dentro das unidades de terapia intensiva (UTI com o intuito de conhecer a realidade do serviço. Objetivo: Determinar a incidência e os fatores associados ao desmame simples, difícil e prolongado em pacientes internados em uma UTI geral adulto. Materiais e Métodos: Estudo de corte prospectivo realizado em um Hospital de Grande Porte no interior do Estado do Rio Grande do Sul - Brasil, entre janeiro e abril de 2014. Foram incluídos 25 pacientes submetidos à ventilação mecânica invasiva (VM em tempo superior a 24 horas e que realizaram o teste de respiração espontânea. Resultados: A incidência de desmame simples, difícil e prolongado foi de 52% (n=13, 32% (n=8 e 16% (n=4, respectivamente. Os dias de internação na UTI (p=0,039, dias de VM (p=0,002 e dias de desmame da VM (p<0,001 foram superiores no grupo desmame prolongado. A incidência de pneumonia associada à VM (PAV (p=0,016, realização de traqueostomia (p=0,045, VM prolongada (p=0,011 e VM controlada prolongada (p=0,028 foi maior no grupo desmame prolongado. Houve uma tendência de maior mortalidade na UTI no grupo desmame prolongado, no entanto, sem diferença estatisticamente significativa (p=0,066. Conclusão: O desmame prolongado está associado ao aumento nos dias de internação na UTI, dias de VM e dias de desmame da VM, assim como na incidência de PAV, realização de traqueostomia, VM prolongada e VM controlada prolongada. Esses resultados nos mostram que nenhum esforço deve ser poupado em relação ao desmame, devendo esse ser otimizado a fim de evitar ou pelo menos reduzir complicações e intervenções

  18. Cholestasis sepsis at neonatology ward and neonatal Intensive Care Unit Cipto Mangunkusumo Hospital 2007 : incidence, mortality rate and associated risk factors

    Directory of Open Access Journals (Sweden)

    Kadim S. Bachtiar

    2008-06-01

    Full Text Available Cholestatic jaundice represents serious pathological condition. Septic-cholestasis is a kind of hepato-cellular cholestasis that occured during or after sepsis caused by biliary flow obstruction. This is a cohort study from February to June 2007 on neonatal sepsis patients at Neonatology ward Department of Child Health Faculty of Medicine University of Indonesia-Cipto Mangunkusumo General National Hospital. Aim of this study is to find out the incidence of intrahepatic cholestasis in neonatal sepsis, associated risk factors, and mortality rate in neonatal cholestasis-sepsis. From 138 neonatal sepsis patients, the incidence of intrahepatic cholestasis is 65.9%. None of the risk factors tested in this study showed statistically significant result. Mortality rate of neonatal cholestasis-sepsis is 52.8%. (Med J Indones 2008; 17: 107-13Keywords: cholestasis intrahepatic, neonatal sepsis, cholestasis sepsis, conjugated hyperbilirubinemia

  19. Measurement of signal intensity depth profiles in rat brains with cardiac arrest maintaining primary temperature by wide-field optical coherence tomography.

    Science.gov (United States)

    Sato, Manabu; Nomura, Daisuke; Tsunenari, Takashi; Nishidate, Izumi

    2010-09-10

    We have already reported that after an injection for euthanasia, the signal intensity of optical coherence tomography (OCT) images are 2.7 times increased before cardiac arrest (CA) using OCT and rat brains without temperature control to show the potential of OCT to monitor tissue viability in brains [Appl. Opt.48, 4354 (2009)APOPAI0003-693510.1364/AO.48.004354]. In this paper, we similarly measured maintaining the primary temperature of rat brains. It was confirmed that when maintaining the primary temperature, the time courses of the ratios of signal intensity (RSIs) were almost the same as those without temperature control. RSIs after CA varied from 1.6 to 4.5 and depended on positions measured in tissues. These results mean that the OCT technique has clinical potential for applications to monitor or diagnose a focal degraded area, such as cerebral infarctions due to focal ischemia in brains.

  20. Relationship between peri-strut low intensity areas and vascular healing response after everolimus-eluting bioresorbable scaffold implantation: An optical coherence tomography study.

    Science.gov (United States)

    Sato, Takao; Jose, John; El-Mawardy, Mohamed; Sulimov, Dmitriy S; Tölg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-04-01

    Peri-strut low intensity areas (PLIA) surrounding metallic coronary stent struts on optical coherence tomography (OCT) images have been histologically related to delayed healing and inflammation, and have been associated with neointimal proliferation. The relationship between PLIA and vascular healing response after bioresorbable scaffold (BRS) implantation remains unclear. This study includes 38 consecutive patients (50 scaffolds) evaluated using OCT 12 months after BRS implantation. Mean and percent neointimal area were quantified. A PLIA was defined as a peri-strut region with an homogenous lower intensity appearance than the surrounding tissue on OCT images without significant signal attenuation. Cross sections were scored as follows: score 0, no PLIA; score 1, BRS implantation appears to be significantly associated with neointimal formation. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  1. Incidence of ventilator-associated pneumonia in an intensive care unit Incidência de pneumonia associada à ventilação mecânica em uma Unidade de Terapia Intensiva

    Directory of Open Access Journals (Sweden)

    Tatiana Gaffuri da Silva

    2017-10-01

    Full Text Available Objetivo: Identificar a incidência de pneumonia associada à ventilação mecânica (PAV em usuários hospitalizados em uma unidade de terapia intensiva. Método: Trata-se de um estudo transversal, documental e retrospectivo. Os dados foram coletados através de busca nas fichas do Serviço de Controle de Infecções Relacionadas à Assistência à Saúde no período de agosto de 2014 a março de 2015 após aprovação no Comitê de Ética em Pesquisa da UFFS com CAEE 45124915100005564. Tabulados no programa Excel e analisados através de estatística descritiva e analítica, com o auxílio do software SPSS 20.0. Resultados: Evidenciaram incidência de 29% de Pneumonia Associada à Ventilação Mecânica, com destaque para o Staphylococcuss no aspirado traqueal e mortalidade de 44%. Conclusão: Revelou índices compatíveis com dados de outros estudos e com o preconizado pela ANVISA. No entanto, sugestiona capacitação aos profissionais envolvidos no cuidado. Descritores: UTI, Enfermagem, Pneumonia Associada a Ventilação Mecânica.

  2. Severe metabolic or mixed acidemia on intensive care unit admission: incidence, prognosis and administration of buffer therapy. A prospective, multiple-center study.

    Science.gov (United States)

    Jung, Boris; Rimmele, Thomas; Le Goff, Charlotte; Chanques, Gérald; Corne, Philippe; Jonquet, Olivier; Muller, Laurent; Lefrant, Jean-Yves; Guervilly, Christophe; Papazian, Laurent; Allaouchiche, Bernard; Jaber, Samir

    2011-01-01

    In this study, we sought describe the incidence and outcomes of severe metabolic or mixed acidemia in critically ill patients as well as the use of sodium bicarbonate therapy to treat these illnesses. We conducted a prospective, observational, multiple-center study. Consecutive patients who presented with severe acidemia, defined herein as plasma pH below 7.20, were screened. The incidence, sodium bicarbonate prescription and outcomes of either metabolic or mixed severe acidemia were analyzed. Among 2, 550 critically ill patients, 200 (8%) presented with severe acidemia, and 155 (6% of the total admissions) met the inclusion criteria. Almost all patients needed mechanical ventilation and vasopressors during their ICU stay, and 20% of them required renal replacement therapy within the first 24 hours of their ICU stay. Severe metabolic or mixed acidemia was associated with a mortality rate of 57% in the ICU. Delay of acidemia recovery as opposed to initial pH value was associated with increased mortality in the ICU. The type of acidemia did not influence the decision to administer sodium bicarbonate. The incidence of severe metabolic or mixed acidemia in critically ill patients was 6% in the present study, and it was associated with a 57% mortality rate in the ICU. In contradistinction with the initial acid-base parameters, the rapidity of acidemia recovery was an independent risk factor for mortality. Sodium bicarbonate prescription was very heterogeneous between ICUs. Further studies assessing specific treatments may be of interest in this population.

  3. Severe metabolic or mixed acidemia on intensive care unit admission: incidence, prognosis and administration of buffer therapy. a prospective, multiple-center study

    Science.gov (United States)

    2011-01-01

    Introduction In this study, we sought describe the incidence and outcomes of severe metabolic or mixed acidemia in critically ill patients as well as the use of sodium bicarbonate therapy to treat these illnesses. Methods We conducted a prospective, observational, multiple-center study. Consecutive patients who presented with severe acidemia, defined herein as plasma pH below 7.20, were screened. The incidence, sodium bicarbonate prescription and outcomes of either metabolic or mixed severe acidemia were analyzed. Results Among 2, 550 critically ill patients, 200 (8%) presented with severe acidemia, and 155 (6% of the total admissions) met the inclusion criteria. Almost all patients needed mechanical ventilation and vasopressors during their ICU stay, and 20% of them required renal replacement therapy within the first 24 hours of their ICU stay. Severe metabolic or mixed acidemia was associated with a mortality rate of 57% in the ICU. Delay of acidemia recovery as opposed to initial pH value was associated with increased mortality in the ICU. The type of acidemia did not influence the decision to administer sodium bicarbonate. Conclusions The incidence of severe metabolic or mixed acidemia in critically ill patients was 6% in the present study, and it was associated with a 57% mortality rate in the ICU. In contradistinction with the initial acid-base parameters, the rapidity of acidemia recovery was an independent risk factor for mortality. Sodium bicarbonate prescription was very heterogeneous between ICUs. Further studies assessing specific treatments may be of interest in this population. PMID:21995879

  4. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  5. Intense Far-Infrared Free-Electron Laser-Pulses with a Length of 6 Optical Cycles

    NARCIS (Netherlands)

    Knippels, G.M.H.; R F X A M Mols,; van der Meer, A. F. G.; Oepts, D.; van Amersfoort, P. W.

    1995-01-01

    Second-order optical autocorrelation measurements are reported for a far-infrared free-electron laser. Second-harmonic generation in an 840-mu m-long CdTe crystal is used to provide the nonlinear autocorrelation signal. At wavelengths of 10.4 and 24.5 mu m, FWHM pulse durations of 220 and 500 fs,

  6. Incidence of Secondary Cancer Development After High-Dose Intensity-Modulated Radiotherapy and Image-Guided Brachytherapy for the Treatment of Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Housman, Douglas M.; Pei Xin; Alicikus, Zumre; Magsanoc, Juan Martin; Dauer, Lawrence T.; St Germain, Jean; Yamada, Yoshiya; Kollmeier, Marisa; Cox, Brett; Zhang Zhigang

    2012-01-01

    Purpose: To report the incidence and excess risk of second malignancy (SM) development compared with the general population after external beam radiotherapy (EBRT) and brachytherapy to treat prostate cancer. Methods and Materials: Between 1998 and 2001, 1,310 patients with localized prostate cancer were treated with EBRT (n = 897) or brachytherapy (n = 413). We compared the incidence of SMs in our patients with that of the general population extracted from the National Cancer Institute’s Surveillance, Epidemiology, and End Results data set combined with the 2000 census data. Results: The 10-year likelihood of SM development was 25% after EBRT and 15% after brachytherapy (p = .02). The corresponding 10-year likelihood for in-field SM development in these groups was 4.9% and 1.6% (p = .24). Multivariate analysis showed that EBRT vs. brachytherapy and older age were the only significant predictors for the development of all SMs (p = .037 and p = .030), with a trend for older patients to develop a SM. The increased incidence of SM for EBRT patients was explained by the greater incidence of skin cancer outside the radiation field compared with that after brachytherapy (10.6% and 3.3%, respectively, p = .004). For the EBRT group, the 5- and 10-year mortality rate was 1.96% and 5.1% from out-of field cancer, respectively; for in-field SM, the corresponding mortality rates were 0.1% and 0.7%. Among the brachytherapy group, the 5- and 10-year mortality rate related to out-of field SM was 0.8% and 2.7%, respectively. Our observed SM rates after prostate RT were not significantly different from the cancer incidence rates in the general population. Conclusions: Using modern sophisticated treatment techniques, we report low rates of in-field bladder and rectal SM risks after prostate cancer RT. Furthermore, the likelihood of mortality secondary to a SM was unusual. The greater rate of SM observed with EBRT vs. brachytherapy was related to a small, but significantly increased

  7. Incidence and nature of medication errors in neonatal intensive care with strategies to improve safety - A review of the current literature

    NARCIS (Netherlands)

    Chedoe, Indra; Molendijk, Harry A.; Dittrich, Suzanne T. A. M.; Jansman, Frank G. A.; Harting, Johannes W.; Brouwers, Jacobus R. B. J.; Taxis, Katja

    2007-01-01

    Neonates are highly vulnerable to medication errors because of their extensive exposure to medications in the neonatal intensive care unit (NICU), the general lack of evidence on pharmacotherapeutic interventions in neonates and the lack of neonate-specific formulations. We searched PubMed and

  8. Characterization of the Performance of Sapphire Optical Fiber in Intense Radiation Fields, when Subjected to Very High Temperatures

    Science.gov (United States)

    Petrie, Christian M.

    The U.S. Department of Energy is interested in extending optically-based instrumentation from non-extreme environments to extremely high temperature radiation environments for the purposes of developing in-pile instrumentation. The development of in-pile instrumentation would help support the ultimate goal of understanding the behavior and predicting the performance of nuclear fuel systems at a microstructural level. Single crystal sapphire optical fibers are a promising candidate for in-pile instrumentation due to the high melting temperature and radiation hardness of sapphire. In order to extend sapphire fiber-based optical instrumentation to high temperature radiation environments, the ability of sapphire fibers to adequately transmit light in such an environment must first be demonstrated. Broadband optical transmission measurements of sapphire optical fibers were made in-situ as the sapphire fibers were heated and/or irradiated. The damage processes in sapphire fibers were also modeled from the primary knock-on event from energetic neutrons to the resulting damage cascade in order to predict the formation of stable defects that ultimately determine the resulting change in optical properties. Sapphire optical fibers were shown to withstand temperatures as high as 1300 °C with minimal increases in optical attenuation. A broad absorption band was observed to grow over time without reaching a dynamic equilibrium when the sapphire fiber was heated at temperatures of 1400 °C and above. The growth of this absorption band limits the use of sapphire optical fibers, at least in air, to temperatures of 1300 °C and below. Irradiation of sapphire fibers with gamma rays caused saturation of a defect center located below 500 nm, and extending as far as ~1000 nm, with little effect on the transmission at 1300 and 1550 nm. Increasing temperature during gamma irradiation generally reduced the added attenuation. Reactor irradiation of sapphire fibers caused an initial rapid

  9. Vavilov-Cherenkov radiation as a cause of transition radiation anomalous intensity in case of electron grazing incidence on the silver surface

    International Nuclear Information System (INIS)

    Zrelov, V.P.; Ruzicka, J.

    1979-01-01

    On the basis of the Vavilov-Cherenkov effect the anomaly in the transition radiation (TR) spectrum is explained which has been first observed by Boersch for grazing particle incidence on the silver surface. The contribution of the Vavilov-Cherenkov radiation to the angle distribution of photons of the TR is estimated. Special attention is drawn to a possibility of the nonthreshold character of Vavilov-Cherenkov radiation in such a medium as silver, and to a necessity of creating a complete theory of Vavilov-Cherenkov radiation for absorbing media

  10. Effect of low-intensity low-dose rate irradiation on the incidence and the development of spontaneous leukosis in AKR mice

    International Nuclear Information System (INIS)

    Burlakova, E.B.; Erokhin, V.N.

    2001-01-01

    Development of spontaneous leukosis in AKR mice is accelerated by irradiation with low doses of 1.2-2.4 cGy and low dose rate 0.06 cGy/day. The leukoses incidence rate increases. Deaths of the animals from leukosis occurs earlier, shortening the average and maximum life-spans of the animals. The dynamics of changes in the mass of organs of the immune systems (thymus and spleen) shows extrema. The moment of reaching the extremum correlates with the maximum rate of animals' deaths [ru

  11. Clinical Characteristics and Prognosis of Peri-strut Low-intensity Area Detected by Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    De-Wei Wu

    2015-01-01

    Conclusions: PLIA detected by OCT was positively correlated with higher serum lipid level, history of cerebrovascular disease and initial presentation of ACS, and negatively correlated with stent implantation time. Patients with PLIA were more likely to have UA than those with high-intensity while no significant difference was found in MACEs.

  12. A high-speed, reconfigurable, channel- and time-tagged photon arrival recording system for intensity-interferometry and quantum optics experiments

    Science.gov (United States)

    Girish, B. S.; Pandey, Deepak; Ramachandran, Hema

    2017-08-01

    We present a compact, inexpensive multichannel module, APODAS (Avalanche Photodiode Output Data Acquisition System), capable of detecting 0.8 billion photons per second and providing real-time recording on a computer hard-disk, of channel- and time-tagged information of the arrival of upto 0.4 billion photons per second. Built around a Virtex-5 Field Programmable Gate Array (FPGA) unit, APODAS offers a temporal resolution of 5 nanoseconds with zero deadtime in data acquisition, utilising an efficient scheme for time and channel tagging and employing Gigabit ethernet for the transfer of data. Analysis tools have been developed on a Linux platform for multi-fold coincidence studies and time-delayed intensity interferometry. As illustrative examples, the second-order intensity correlation function ( g 2) of light from two commonly used sources in quantum optics —a coherent laser source and a dilute atomic vapour emitting spontaneously, constituting a thermal source— are presented. With easy reconfigurability and with no restriction on the total record length, APODAS can be readily used for studies over various time scales. This is demonstrated by using APODAS to reveal Rabi oscillations on nanosecond time scales in the emission of ultracold atoms, on the one hand, and, on the other hand, to measure the second-order correlation function on the millisecond time scales from tailored light sources. The efficient and versatile performance of APODAS promises its utility in diverse fields, like quantum optics, quantum communication, nuclear physics, astrophysics and biology.

  13. The incidence of nosocomial infection in the Intensive Care Unit, Hospital Universiti Kebangsaan Malaysia: ICU-acquired nosocomial infection surveillance program 1998-1999.

    Science.gov (United States)

    Rozaidi, S W; Sukro, J; Dan, A

    2001-06-01

    CU-acquired nosocomial infection (NI) remains one of the major causes of ICU mortality. This study presents the incidence of ICU-acquired nosocomial infection in ICU HUKM for the years 1998 and 1999, as part of the ongoing ICU-acquired nosocomial infection surveillance program. The overall incidence was 23%. The main types of NI was lower respiratory tract infection (15.3%), primary bacteraemia (8.1%), ventilator associated pneumonia (5.4%), urinary tract infection (2.0%), skin infection (1.6%) central venous catheter sepsis (1.2%) and surgical skin infection (0.8%). The overall culture positive nosocomial infection rate was only 12.1%, majority from the lungs (12.6%), blood (7.3%), skin swabs (2.0%), and urine (1.6%). The main gram-negative organism cultured was Acinetobacter sp. (19%) and Staph. aureus (8.5%) was the gram-positive organism. The overall ICU mortality rate was 27.5% of which 60.9% of patients who died were attributed directly to sepsis.

  14. Generation of a chirp-free optical pulse train with tunable pulse width based on a polarization modulator and an intensity modulator.

    Science.gov (United States)

    Pan, Shilong; Yao, Jianping

    2009-07-15

    A simple method for the generation of a chirp-free optical pulse train with tunable pulse width using a polarization modulator (PolM) and a zero-chirp intensity modulator (IM) is proposed and demonstrated. In the proposed system, a light wave with its polarization direction oriented at an angle of 45 degrees with respect to the principal axis of the PolM is polarization modulated by a sinusoidal drive signal. An optical polarizer is connected after the PolM to convert the polarization-modulated signals to a pulse train with the main peaks having a narrow pulse width. Then, the main peaks are selected by the IM, leading to the generation of a short optical pulse train with a repetition rate that is identical to or twice the frequency of the sinusoidal drive signal, depending on the dc bias of the IM. The pulse width of the generated pulse is easily tuned by adjusting the phase modulation index of the PolM. An experiment is carried out, and a pulse train with a duty cycle as small as 8.16% is generated.

  15. Silicon coupled-resonator optical-waveguide-based biosensors using light-scattering pattern recognition with pixelized mode-field-intensity distributions.

    Science.gov (United States)

    Wang, Jiawei; Yao, Zhanshi; Lei, Ting; Poon, Andrew W

    2014-12-18

    Chip-scale, optical microcavity-based biosensors typically employ an ultra-high-quality microcavity and require a precision wavelength-tunable laser for exciting the cavity resonance. For point-of-care applications, however, such a system based on measurements in the spectral domain is prone to equipment noise and not portable. An alternative microcavity-based biosensor that enables a high sensitivity in an equipment-noise-tolerant and potentially portable system is desirable. Here, we demonstrate the proof-of-concept of such a biosensor using a coupled-resonator optical-waveguide (CROW) on a silicon-on-insulator chip. The sensing scheme is based on measurements in the spatial domain, and only requires exciting the CROW at a fixed wavelength and imaging the out-of-plane elastic light-scattering intensity patterns of the CROW. Based on correlating the light-scattering intensity pattern at a probe wavelength with the light-scattering intensity patterns at the CROW eigenstates, we devise a pattern-recognition algorithm that enables the extraction of a refractive index change, Δn, applied upon the CROW upper-cladding from a calibrated set of correlation coefficients. Our experiments using an 8-microring CROW covered by NaCl solutions of different concentrations reveal a Δn of ~1.5 × 10(-4) refractive index unit (RIU) and a sensitivity of ~752 RIU(-1), with a noise-equivalent detection limit of ~6 × 10(-6) RIU.

  16. Focal construct geometry for high intensity energy dispersive x-ray diffraction based on x-ray capillary optics

    Energy Technology Data Exchange (ETDEWEB)

    Li, Fangzuo; Liu, Zhiguo; Sun, Tianxi, E-mail: stx@bnu.edu.cn; Jiang, Bowen; Zhu, Yu [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2016-03-14

    We presented a focal construct geometry (FCG) method for high intensity energy dispersive X-ray diffraction by utilizing a home-made ellipsoidal single-bounce capillary (ESBC) and a polycapillary parallel X-ray lens (PPXRL). The ESBC was employed to focus the X-rays from a conventional laboratory source into a small focal spot and to produce an annular X-ray beam in the far-field. Additionally, diffracted polychromatic X-rays were confocally collected by the PPXRL attached to a stationary energy-resolved detector. Our FCG method based on ESBC and PPXRL had achieved relatively high intensity diffraction peaks and effectively narrowed the diffraction peak width which was helpful in improving the potential d-spacing resolution for material phase analysis.

  17. A series approximation model for optical light transport and output intensity field distribution in large aspect ratio cylindrical scintillation crystals

    Energy Technology Data Exchange (ETDEWEB)

    Tobias, Benjamin John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-09

    A series approximation has been derived for the transport of optical photons within a cylindrically symmetric light pipe and applied to the task of evaluating both the origin and angular distribution of light reaching the output plane. This analytic expression finds particular utility in first-pass photonic design applications since it may be evaluated at a very modest computational cost and is readily parameterized for relevant design constraints. It has been applied toward quantitative exploration of various scintillation crystal preparations and their impact on both quantum efficiency and noise, reproducing sensible dependencies and providing physical justification for certain gamma ray camera design choices.

  18. Combined effects of intense laser field, electric and magnetic fields on the nonlinear optical properties of the step-like quantum well

    Energy Technology Data Exchange (ETDEWEB)

    Kasapoglu, E., E-mail: ekasap@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia-UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mora-Ramos, M.E. [Facultad de Ciencias, Universidad Autónoma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Restrepo, R.L. [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia-UdeA, Calle 70 No. 52-21, Medellín (Colombia); Escuela de Ingeniería de Antioquia-EIA, Medellín (Colombia); Ungan, F.; Yesilgul, U.; Sari, H. [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Sökmen, I. [Department of Physics, Dokuz Eylül University, 35160 Buca, İzmir (Turkey)

    2015-03-15

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change for transition between two lower-lying electronic levels in the step-like GaAs/Ga{sub 1−x}Al{sub x}As quantum well under external electric and magnetic fields are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass and parabolic band approximations. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the well dimensions and the effects of external fields. By changing the intensities of the electric, magnetic and non-resonant intense laser fields together with the well dimensions, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • Augmentation of laser-field results in red shift in total AC spectra. • Magnetic field induces a blue-shift in the resonant peak. • Resonant peak position shifts to red with effect of electric field. • Resonant peak of total AC shifts to the higher photon energies with increasing well width.

  19. Combined effects of intense laser field, electric and magnetic fields on the nonlinear optical properties of the step-like quantum well

    International Nuclear Information System (INIS)

    Kasapoglu, E.; Duque, C.A.; Mora-Ramos, M.E.; Restrepo, R.L.; Ungan, F.; Yesilgul, U.; Sari, H.; Sökmen, I.

    2015-01-01

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change for transition between two lower-lying electronic levels in the step-like GaAs/Ga 1−x Al x As quantum well under external electric and magnetic fields are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass and parabolic band approximations. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the well dimensions and the effects of external fields. By changing the intensities of the electric, magnetic and non-resonant intense laser fields together with the well dimensions, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • Augmentation of laser-field results in red shift in total AC spectra. • Magnetic field induces a blue-shift in the resonant peak. • Resonant peak position shifts to red with effect of electric field. • Resonant peak of total AC shifts to the higher photon energies with increasing well width

  20. A prospective, longitudinal study to assess use of continuous and reactive low-pressure mattresses to reduce pressure ulcer incidence in a pediatric intensive care unit.

    Science.gov (United States)

    García-Molina, Pablo; Balaguer-López, Evelin; Torra I Bou, Joan Enric; Alvarez-Ordiales, Adan; Quesada-Ramos, Cristina; Verdú-Soriano, José

    2012-07-01

    Pressure between bony prominences and sleep surfaces, as well as pressure from the use of medical devices, put children admitted to pediatric intensive care units (PICUs) at risk of developing pressure ulcers (PUs). To assess the effect of two pediatric-specific, continuous and reactive low-pressure mattresses on the incidence of PUs, an observational, descriptive, prospective, longitudinal (2009-2011) study was conducted among PICU patients. The two pediatric mattresses - one for children weighing between 500 g and 6 Kg and another for children weighing more than 6 Kg - were provided to patients at risk for PUs (Braden-Q ≤16, Neonatal Skin Risk Assessment Scale [NSRAS] ≤13, or per nurse assessment of clinical need). Between 2009 and 2011, 30 children (13 [43.3%] girls and 17 [56.7%] boys), ages 0 to 10 years, at risk of developing PUs (NSRAS risk: n = 14 [13.2 ± 3.03] and Braden-Q risk: n = 10 [10.4 ± 2.4]) were placed on the study mattresses for a median of 4 (range 1 to 25) days. Primary reasons for PICU admission included disorders of the respiratory system (40%), infectious and parasitic diseases (23.3%), and illnesses of the musculoskeletal system and connective tissue (10%). All other PU prevention strategies (eg, repositioning, specialty devices) used as part of standard care protocols also were implemented. Of the 30 participants, only one (3.3%) (confidence interval [CI] 95% = 0.08 -17.2%) developed a nondevice-related PU. No adverse events occurred. A 2008 incidence study in the same PICU, before use of these special surfaces, found a cumulative incidence of 20% nondevice-related PUs. The observed incidence rate of nonmedical device-related PUs in this high-risk population placed on these mattresses is encouraging and warrants future research.

  1. The additional benefit of residual spraying and insecticide-treated curtains for dengue control over current best practice in Cuba: Evaluation of disease incidence in a cluster randomized trial in a low burden setting with intensive routine control.

    Science.gov (United States)

    Toledo, Maria Eugenia; Vanlerberghe, Veerle; Rosales, Julio Popa; Mirabal, Mayelin; Cabrera, Pedro; Fonseca, Viviana; Gómez Padrón, Tania; Pérez Menzies, Mirtha; Montada, Domingo; Van der Stuyft, Patrick

    2017-11-01

    Aedes control interventions are considered the cornerstone of dengue control programmes, but there is scarce evidence on their effect on disease. We set-up a cluster randomized controlled trial in Santiago de Cuba to evaluate the entomological and epidemiological effectiveness of periodical intra- and peri-domiciliary residual insecticide (deltamethrin) treatment (RIT) and long lasting insecticide treated curtains (ITC). Sixty three clusters (around 250 households each) were randomly allocated to two intervention (RIT and ITC) and one control arm. Routine Aedes control activities (entomological surveillance, source reduction, selective adulticiding, health education) were applied in the whole study area. The outcome measures were clinical dengue case incidence and immature Aedes infestation. Effectiveness of tools was evaluated using a generalized linear regression model with a negative binomial link function. Despite significant reduction in Aedes indices (Rate Ratio (RR) 0.54 (95%CI 0.32-0.89) in the first month after RIT, the effect faded out over time and dengue incidence was not reduced. Overall, in this setting there was no protective effect of RIT or ITC over routine in the 17months intervention period, with for house index RR of 1.16 (95%CI 0.96-1.40) and 1.25 (95%CI 1.03-1.50) and for dengue incidence RR of 1.43 (95%CI 1.08-1.90) and 0.96 (95%CI 0.72-1.28) respectively. The monthly dengue incidence rate (IR) at cluster level was best explained by epidemic periods (Incidence Rate Ratio (IRR) 5.50 (95%CI 4.14-7.31)), the IR in bordering houseblocks (IRR 1.03 (95%CI 1.02-1.04)) and the IR pre-intervention (IRR 1.02 (95%CI 1.00-1.04)). Adding RIT to an intensive routine Aedes control programme has a transient effect on the already moderate low entomological infestation levels, while ITC did not have any effect. For both interventions, we didn't evidence impact on disease incidence. Further studies are needed to evaluate impact in settings with high Aedes

  2. Optical intensities of Pr3+ ions in transparent oxyfluoride glass and glass-ceramic. Applications of the standard and modified Judd-Ofelt theories

    International Nuclear Information System (INIS)

    Genova, R.T.; Martin, I.R.; Rodriguez-Mendoza, U.R.; Lahoz, F.; Lozano-Gorrin, A.D.; Nunez, P.; Gonzalez-Platas, J.; Lavin, V.

    2004-01-01

    The optical characterisation of Pr 3+ ions in transparent SiO 2 -Al 2 O 3 -CdF 2 -PbF 2 -YF 3 based glass and glass-ceramic have been performed. From absorption and emission spectra the oscillator strengths of the 4f 2 -4f 2 electronic transitions have been obtained. The intensity parameters have been calculated using both the Judd-Ofelt theory and the modified theory developed by Kornienko, Kaminskii and Dunina. A comparison of the experimental oscillator strengths, the spontaneous emission probabilities and the lifetimes of the 3 P 0 level and those calculated using the above theoretical procedures has been performed for both samples. The root mean square deviation found using the standard Judd-Ofelt theory is larger than the value obtained with the modified treatment

  3. Microstructure-mediated Optical Effects in Southern African Snakes

    Directory of Open Access Journals (Sweden)

    Singh Ishan

    2017-01-01

    Full Text Available The scales of the African Viper Bitis arietans were tested for optical effects. Spectral intensity was recorded at incident angles over the visible spectrum for dark, pale, and ventral scale regions. The lowest spectral intensity recordings were associated with scales which have the greatest level of micro-structuring. Our results indicate that scale appearance in B. arietans is a product of microstructure-mediated optical effects. The optical effect may play a role in improving the ecological performance of the snake in its natural environment.

  4. Microstructure-mediated Optical Effects in Southern African Snakes

    Science.gov (United States)

    Singh, Ishan; Alexander, Graham

    2017-03-01

    The scales of the African Viper Bitis arietans were tested for optical effects. Spectral intensity was recorded at incident angles over the visible spectrum for dark, pale, and ventral scale regions. The lowest spectral intensity recordings were associated with scales which have the greatest level of micro-structuring. Our results indicate that scale appearance in B. arietans is a product of microstructure-mediated optical effects. The optical effect may play a role in improving the ecological performance of the snake in its natural environment.

  5. Intense blue upconversion emission and intrinsic optical bistability in Tm3+/Yb3+/Zn2+ tridoped YVO4 phosphors

    Science.gov (United States)

    Yadav, Manglesh; Mondal, Manisha; Mukhopadhyay, Lakshmi; Rai, Vineet Kumar

    2018-04-01

    Tm3+/Yb3+/Zn2+:yttrium metavanadate (YVO4) phosphors prepared through chemical coprecipitation and the solid state reaction method have been structurally characterized by an x-ray diffraction (XRD) study. Photoluminescence study of the developed phosphors under ultraviolet (UV) and near infrared (NIR) excitation has been performed. The excitation spectrum of the tetragonal zircon type YVO4 phosphors corresponding to the emission at ∼476 nm exhibits a broad excitation peak in the 250–350 nm region, which is due to charge distribution in the {{{{VO}}}4}3- group. Under 980 nm CW diode laser excitation, enhancements of about ∼3000 times and ∼40 times have been observed for the blue band in the tridoped Tm3+Yb3+Zn2+:YVO4 phosphors compared to those of the Tm3+:YVO4 singly and Tm3+/Yb3+:YVO4 codoped phosphors, respectively. A downconversion (DC) emission study shows an enhancement of about ∼50 times for the blue band in the tridoped phosphors compared to that of the singly doped phosphors. Optical bistability (OB) behavior of the developed phosphors has been also investigated upon 980 nm excitation. The calculated Commission Internationale de l’Éclairage (CIE) color coordinates lie in the blue region with 96.5% color purity under 980 nm excitation, having a color temperature of ∼3400 K. Our observations show that the developed phosphors may be suitably used in dual mode luminescence spectroscopy, display devices, and UV LED chips.

  6. Using Multivariate Regression Model with Least Absolute Shrinkage and Selection Operator (LASSO) to Predict the Incidence of Xerostomia after Intensity-Modulated Radiotherapy for Head and Neck Cancer

    Science.gov (United States)

    Ting, Hui-Min; Chang, Liyun; Huang, Yu-Jie; Wu, Jia-Ming; Wang, Hung-Yu; Horng, Mong-Fong; Chang, Chun-Ming; Lan, Jen-Hong; Huang, Ya-Yu; Fang, Fu-Min; Leung, Stephen Wan

    2014-01-01

    Purpose The aim of this study was to develop a multivariate logistic regression model with least absolute shrinkage and selection operator (LASSO) to make valid predictions about the incidence of moderate-to-severe patient-rated xerostomia among head and neck cancer (HNC) patients treated with IMRT. Methods and Materials Quality of life questionnaire datasets from 206 patients with HNC were analyzed. The European Organization for Research and Treatment of Cancer QLQ-H&N35 and QLQ-C30 questionnaires were used as the endpoint evaluation. The primary endpoint (grade 3+ xerostomia) was defined as moderate-to-severe xerostomia at 3 (XER3m) and 12 months (XER12m) after the completion of IMRT. Normal tissue complication probability (NTCP) models were developed. The optimal and suboptimal numbers of prognostic factors for a multivariate logistic regression model were determined using the LASSO with bootstrapping technique. Statistical analysis was performed using the scaled Brier score, Nagelkerke R2, chi-squared test, Omnibus, Hosmer-Lemeshow test, and the AUC. Results Eight prognostic factors were selected by LASSO for the 3-month time point: Dmean-c, Dmean-i, age, financial status, T stage, AJCC stage, smoking, and education. Nine prognostic factors were selected for the 12-month time point: Dmean-i, education, Dmean-c, smoking, T stage, baseline xerostomia, alcohol abuse, family history, and node classification. In the selection of the suboptimal number of prognostic factors by LASSO, three suboptimal prognostic factors were fine-tuned by Hosmer-Lemeshow test and AUC, i.e., Dmean-c, Dmean-i, and age for the 3-month time point. Five suboptimal prognostic factors were also selected for the 12-month time point, i.e., Dmean-i, education, Dmean-c, smoking, and T stage. The overall performance for both time points of the NTCP model in terms of scaled Brier score, Omnibus, and Nagelkerke R2 was satisfactory and corresponded well with the expected values. Conclusions

  7. Time-delayed intensity-interferometry of the emission from ultracold atoms in a steady-state magneto-optical trap

    Science.gov (United States)

    Muhammed Shafi, K.; Pandey, Deepak; Suryabrahmam, Buti; Girish, B. S.; Ramachandran, Hema

    2016-01-01

    Time-delayed intensity-interferometry (TDII) measurements of the fluorescent emission from an ultracold ensemble of thermal 87Rb atoms in a steady-state magneto-optical trap are presented, which reveal the underlying coherent and incoherent dynamics of the atoms. Measurements carried out with a 5 ns time resolution yielded a second-order intensity correlation function with the theoretically predicted value of 2 at zero delay. In addition coherent Rabi oscillations were seen for up to five full periods—much longer than the spontaneous emission lifetime of the excited state of Rb. The oscillations were damped out by ˜150 ns, and thereafter an exponential decay observed, from which the mean velocity of atoms and thus, the temperature of the ensemble was estimated. The values so obtained compare well with those determined by standard techniques. It is seen that TDII permits a quantitative study of the coherent and incoherent processes, even in a large ensemble of independent atomic emitters in random thermal motion. This measurement of second-order correlation powerful technique can reveal hidden periodicities such as coherent Rabi oscillations that are not directly seen in the emission from a large collection of atoms. In addition it can also reveal information about the mean velocity of the thermal ensemble of emitters, even though the Doppler broadening of emission due to the motion of atoms is smaller than the natural linewidth and is not directly measureable.

  8. In vivo rat brain measurements of changes in signal intensity depth profiles as a function of temperature using wide-field optical coherence tomography.

    Science.gov (United States)

    Sato, Manabu; Nomura, Daisuke; Tsunenari, Takashi; Nishidate, Izumi

    2010-10-20

    In our previous study, we used optical coherence tomography (OCT) and reported an increase in signal intensity of depth profiles between euthanasia injection and cardiac arrest (CA), demonstrating the potential as a tool for monitoring/diagnosing brain tissue viability [Appl. Opt.48, 4354 (2009)]. Here, for the first time to our knowledge, we measured three-dimensional (3D) OCT images through a thinned skull changing temperatures in the rat brain. The measurements were made at 10 min intervals for 210 min to evaluate correlations of temperature with heart rate and ratios of signal intensity (RSI). The 3D image area was 4 mm × 4 mm × 2.8 mm. When the temperature was decreased from 28°C to 18°C to reduce tissue viability, the heart rate was found to decrease with an increase in RSI. Negative correlation coefficients (CCs) between temperatures and RSIs, and between heart rate and RSIs, were obtained. This indicates that OCT signals increase with reductions of viability caused by decreases in heart rates and temperatures in tissues. These observations correspond to estimations obtained by multiwavelength diffuse reflectance spectroscopy [Appl. Opt.47, 4164 (2008)]. CCs and stationary RSIs would depend upon measured positions in tissues. Without injections for euthanasia, a similar rapid increase in RSI has also been measured before CA.

  9. Investigation of optical properties of an overdense magnetized plasma lens in the interaction with high-intensity Gaussian laser pulses

    Science.gov (United States)

    Ghorbanalilu, M.; Shokri, B.

    2018-03-01

    Self-focusing of a high-intensity circularly polarized Gaussian laser pulse by an overdense magnetized thin plasma lens is numerically investigated. The quasi-static axial magnetic field can be produced by inverse Faraday effect (IFE) mechanism in laser-plasma interaction. It has been shown that the inclusion of self-transparency, ponderomotive force, and magnetic field effects significantly affect the self-focusing properties. When the strength of the magnetic field increases, the self-focusing property is enhanced for the right and is weakened for the left-handed circularly polarized laser pulse. The ponderomotive force repels electrons from the axis and drives electron cavitation and as a result further lowers the plasma frequency. When the influence of the ponderomotive force is taken into account, self-focusing for both polarizations is strongly affected. The clear difference between the effects of the right- and left-handed circularly polarized pulses may lead us to use them for different experimental applications.

  10. The role of low light intensity: A step towards understanding the connection between light, optic/lens and photovoltaic behavior for Sb2S3 thin-film solar cells

    Science.gov (United States)

    Lojpur, Vesna; Mitrić, Miodrag; Validžić, Ivana Lj

    2018-05-01

    We report here an optic/lens system that we used so far, for cooling the surface of solar cells, the reduction of light intensity and the change of light distribution that reaches the surface of the solar cell. The objective was to improve photovoltaic characteristics under very low light illumination, as well as to understand the connection between light, optic/lens and photovoltaic behavior for Sb2S3 thin-film solar cells. It was found that for all so far designed thin-film solar cells made and based on the synthesized Sb2S3, optics/lens system causes an increase in open circuit voltage (VOC) and short circuit current (ISC) and thus the efficiencies of made solar devices. Values of energy gaps for the thin-films made devices were in the range from 1.4 to 2 eV. Improvements of the photovoltaic response of the designed devices are found to be better at the lower light intensity (5% sun), than at higher intensities of light. For the same intensity of light used optic/lens improves the efficiency of the devices, by changing the light distribution. Other processes that are related to the optics/lens system, leading to an increase in ISC and VOC and consequently to an increase in efficiencies of the designed devices, are investigated.

  11. Mapping rice extent map with crop intensity in south China through integration of optical and microwave images based on google earth engine

    Science.gov (United States)

    Zhang, X.; Wu, B.; Zhang, M.; Zeng, H.

    2017-12-01

    Rice is one of the main staple foods in East Asia and Southeast Asia, which has occupied more than half of the world's population with 11% of cultivated land. Study on rice can provide direct or indirect information on food security and water source management. Remote sensing has proven to be the most effective method to monitoring the cropland in large scale by using temporary and spectral information. There are two main kinds of satellite have been used to mapping rice including microwave and optical. Rice, as the main crop of paddy fields, the main feature different from other crops is flooding phenomenon at planning stage (Figure 1). Microwave satellites can penetrate through clouds and efficiency on monitoring flooding phenomenon. Meanwhile, the vegetation index based on optical satellite can well distinguish rice from other vegetation. Google Earth Engine is a cloud-based platform that makes it easy to access high-performance computing resources for processing very large geospatial datasets. Google has collected large number of remote sensing satellite data around the world, which providing researchers with the possibility of doing application by using multi-source remote sensing data in a large area. In this work, we map rice planting area in south China through integration of Landsat-8 OLI, Sentienl-2, and Sentinel-1 Synthetic Aperture Radar (SAR) images. The flowchart is shown in figure 2. First, a threshold method the VH polarized backscatter from SAR sensor and vegetation index including normalized difference vegetation index (NDVI) and enhanced vegetation index (EVI) from optical sensor were used the classify the rice extent map. The forest and water surface extent map provided by earth engine were used to mask forest and water. To overcome the problem of the "salt and pepper effect" by Pixel-based classification when the spatial resolution increased, we segment the optical image and use the pixel- based classification results to merge the object

  12. A Comparison of Aerosol Optical Property Measurements Made During the DOE Aerosol Intensive Operating Period and Their Effects on Regional Climate

    Science.gov (United States)

    Strawa, Anthony W.; Hallar, A. G.; Arnott, W. P.; Covert, D.; Elleman, R.; Ogren, J.; Schmid, B.; Luu, A.

    2004-01-01

    The amount of radiant energy an aerosol absorbs has profound effects on climate and air quality. It is ironic that aerosol absorption coefficient is one of the most difficult to measure aerosol properties. One of the main purposes of the DOE Aerosol Intensive Operating Period (IOP) flown in May, 2003 was to assess our ability to measure absorption coefficient in situ. This paper compares measurements of aerosol optical properties made during the IOP. Measurements of aerosol absorption coefficient were made by Particle Soot Absorption Photometer (PSAP) aboard the CIRPAS Twin-Otter (U. Washington) and on the DOE Cessna 172 (NOAA-C,MDL). Aerosol absorption coefficient was also measured by a photoacoustic instrument (DRI) that was operated on an aircraft for the first time during the IOP. A new cavity ring-down (CRD) instrument, called Cadenza (NASA-AkC), measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. Absorption coefficient is obtained from the difference of measured extinction and scattering within the instrument. Measurements of absorption coefficient from all of these instruments during appropriate periods are compared. During the IOP, several significant aerosol layers were sampled aloft. These layers are identified in the remote (AATS-14) as well as in situ measurements. Extinction profiles measured by Cadenza are compared to those derived from the Ames Airborne Tracking Sunphotometer (AATS-14, NASA-ARC). The regional radiative impact of these layers is assessed by using the measured aerosol optical properties in a radiative transfer model.

  13. Optical temperature sensing of Er3+/Yb3+ doped LaGdO3 based on fluorescence intensity ratio and lifetime thermometry

    Science.gov (United States)

    Siaï, A.; Haro-González, P.; Horchani Naifer, K.; Férid, M.

    2018-02-01

    The investigation of the fluorescence intensity ratio and the lifetime thermometry techniques for two rare earth perovskites-type oxide (LaGdO3:Er3+ and LaGdO3:Er3+/Yb3+) has been carried out. We have demonstrated that the intensity ratio of thermally coupled levels of erbium (2H11/2 and 4S3/2) is temperature dependant in the range from 283 to 393 K. The sensitivity parameter was found to reach a maximum value of 31 × 10-4 K-1 and 34 × 10-4 K-1 at 393 K and the temperature resolution to be equivalent to 1.61 and 3.1 K, for Er3+ and Er3+/Yb3+ doped oxide, respectively. By studying the temperature dependence of the normalized lifetimes in the range from 293 to 348 K, we proved that the sensitivity of the green emission (4S3/2) is higher than the red one (4F9/2) for both samples, and that it increases from 144 × 10-4 K-1 for LaGdO3:Er3+ to 179 × 10-4 K-1 for LaGdO3:Er3+/Yb3+. The thermal coefficients were quite large in comparison to those calculated for different luminescent materials and reported in literature. The repeatability of measurements was tested by performing heating and cooling cycles for both methods and the results show that these optical techniques have a good repeatability performance. Hence, the LaGdO3: Er3+, Yb3+ oxide has a precise and a satisfying sensitivity associated to a good thermal and chemical stability, suggesting that it can be a potential candidate in temperature sensing.

  14. Grazing Incidence X-Ray Fluorescence of periodic structures – a comparison between X-ray Standing Waves and Geometrical Optics calculations.

    OpenAIRE

    Reinhardt Falk; Nowak Stanislaw H.; Beckhoff Burkhard; Dousse Jean-Claude; Schoengen Max

    2014-01-01

    Grazing incidence X-ray fluorescence spectra of nano-scaled periodic line structures were recorded at the four crystal monochromator beamline in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II. For different tilt angles between the lines and the plane of incidence of the monochromatic synchrotron radiation, spectral features are observed which can be understood and explained with calculations of the emerging X-ray standing wave (XSW) ...

  15. In-line silica capillary tube all-silica fiber-optic Fabry-Perot interferometric sensor for detecting high intensity focused ultrasound fields.

    Science.gov (United States)

    Wang, D H; Wang, S J; Jia, P G

    2012-06-01

    Aiming at detecting high intensity focused ultrasound (HIFU) fields, this letter reports on a novel in-line silica capillary tube all-silica fiber-optic Fabry-Perot (ILSCT-ASFP) interferometric sensor fabricated by splicing a commercially available silica capillary tube to two single-mode fibers. The experimental results show that such a novel ILSCT-ASFP interferometric sensor with a cavity length of ∼60.76 μm has an excellent fringe visibility of up to ∼20 dB, and the fringe visibility is still good when the cavity length extends up to ∼1031.07 μm. The measured wavelength-temperature sensitivity of 0.000858 nm/°C shows that the wavelength drift of the fabricated ILSCT-ASFP interferometric sensor towards temperature is extremely low. Meanwhile, the measurement of HIFU fields by this novel sensor is demonstrated, and the experimental results indicate that the signal-to-noise ratio of the sensing system for sensing a 0.93 MHz HIFU field with a pressure of 2.69 MPa in the focus area can reach 42.8 dB. The corresponding noise equivalent pressure is 0.0194 MPa, and the calculated acoustic sensitivity is 65.4 mV/MPa over a 2.5 MHz measurement bandwidth.

  16. Comparison of intensity-modulated radiotherapy and volumetric-modulated arc therapy dose measurement for head and neck cancer using optical stimulated luminescence dosimeter

    Science.gov (United States)

    Lai, Lu-Han; Chuang, Keh-Shih; Lin, Hsin-Hon; Liu, Yi-Chi; Kuo, Chiung-Wen; Lin, Jao-Perng

    2017-11-01

    The in-vivo dose distributions of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), a newly developed technique, for head and neck cancer have been investigated for several years. The present study used a head-and-neck RANDO phantom to simulate the clinical conditions of nasopharyngeal carcinoma and compare the radiation doses between VMAT and IMRT. Three types of planning target volume (PTV) profiles were targeted by reducing the PTV surface margin by 0, 3, and 5 mm. An optically stimulated luminescence dosimeter was used to measure the surface doses. The results revealed that VMAT provided on average 16.8-13.8% lower surface doses within the PTV target areas than IMRT. When the PTV margin was reduced by 0 mm, the surface doses for IMRT reached their maximum value, accounting for 75.1% of its prescribed dose (Dp); however, the Dp value of VMAT was only 61.1%. When the PTV margin was reduced by 3 or 5 mm, the surface doses decreased considerably. The observed surface doses were insufficient when the tumours invaded the body surface; however, VMAT exerted larger skin-sparing effects than IMRT when the tumours away from the skin. These results suggest that the skin doses for these two techniques are insufficient for surface tumours. Notably, VMAT can provide lower skin doses for deep tumours.

  17. Incidence and outcome of contrast-associated acute kidney injury assessed with Risk, Injury, Failure, Loss, and End-stage kidney disease (RIFLE) criteria in critically ill patients of medical and surgical intensive care units: a retrospective study.

    Science.gov (United States)

    Kim, Myoung Hwa; Koh, Shin Ok; Kim, Eun Jung; Cho, Jin Sun; Na, Sung-Won

    2015-01-01

    Contrast medium used for radiologic tests can decrease renal function. However there have been few studies on contrast-associated acute kidney injury in intensive care unit (ICU) patients. The objective of this study was to evaluate the incidence, characteristics, and outcome of contrast-associated acute kidney injury (CA-AKI) patients using the Risk, Injury, Failure, Loss, and End-stage kidney disease (RIFLE) criteria in critically ill patients in the ICU. We conducted a retrospective study of adult patients who underwent contrast-enhanced radiologic tests from January 2011 to December 2012 in a 30-bed medical ICU and a 24-bed surgical ICU. The study included 335 patients, and the incidence of CA-AKI was 15.5%. The serum creatinine and estimated glomerular filtration rate values in the CA-AKI patients did not recover even at discharge from the hospital compared with the values prior to the contrast use. Among 52 CA-AKI patients, 55.8% (n = 29) had pre-existing kidney injury and 44.2% (n = 23) did not. The CA-AKI patients were divided into risk (31%), injury (31%), and failure (38%) by the RIFLE classification. The percentage of patients in whom AKI progressed to a more severe form (failure, loss, end-stage kidney disease) increased from 38% to 45% during the hospital stay, and the recovery rate of AKI was 17% at the time of hospital discharge. Because the Acute Physiology and Chronic Health Evaluation (APACHE) II score was the only significant variable inducing CA-AKI, higher APACHE II scores were associated with a higher risk of CA-AKI. The ICU and hospital mortality of patients with CA-AKI was significantly higher than in patients without CA-AKI. CA-AKI is associated with increases in hospital mortality, and can be predicted by the APACHE score. NCT01807195 on March. 06. 2013.

  18. Imaging and steering an optical wireless nanoantenna link.

    Science.gov (United States)

    Dregely, Daniel; Lindfors, Klas; Lippitz, Markus; Engheta, Nader; Totzeck, Michael; Giessen, Harald

    2014-07-04

    Optical nanoantennas tailor the transmission and reception of optical signals. Owing to their capacity to control the direction and angular distribution of optical radiation over a broad spectral range, nanoantennas are promising components for optical communication in nanocircuits. Here we measure wireless optical power transfer between plasmonic nanoantennas in the far-field and demonstrate changeable signal routing to different nanoscopic receivers via beamsteering. We image the radiation pattern of single-optical nanoantennas using a photoluminescence technique, which allows mapping of the unperturbed intensity distribution around plasmonic structures. We quantify the distance dependence of the power transmission between transmitter and receiver by deterministically positioning nanoscopic fluorescent receivers around the transmitting nanoantenna. By adjusting the wavefront of the optical field incident on the transmitter, we achieve directional control of the transmitted radiation over a broad range of 29°. This enables wireless power transfer from one transmitter to different receivers.

  19. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  20. GnRH agonist trigger with intensive luteal phase support vs. human chorionic gonadotropin trigger in high responders: an observational study reporting pregnancy outcomes and incidence of ovarian hyperstimulation syndrome.

    Science.gov (United States)

    Christopoulos, Georgios; Vlismas, Antonios; Carby, Anna; Lavery, Stuart; Trew, Geoffrey

    2016-09-01

    A retrospective, cohort study of high-risk patients undergoing IVF treatment was performed to assess if there is a difference in clinical pregnancy rate, live birth rate and the incidence of ovarian hyperstimulation syndrome, when a GnRH agonist (GnRHa) trigger with intensive luteal support is compared to human chorionic gonadotropin (hCG) with standard luteal support. The control group consisted of 382 high-risk patients having a GnRH antagonist protocol with 194 receiving an hCG trigger. All patients had ≥18 follicles ≥11mm or serum oestradiol >18,000pmol/l on the day of trigger. Patients had a single or double embryo transfer at cleavage or blastocyst stage. Logistic regression was used to adjust for differences between the groups. An intention-to-treat analysis of all cycles was performed. No statistically significant differences were observed in terms of positive pregnancy test, clinical pregnancy rate and live birth rate. Only one patient (0.3%) was hospitalized with severe OHSS in the GnRHa group, compared to 26 patients (13%) in the hCG group. In conclusion, GnRHa trigger is associated with similar pregnancy rates with hCG trigger and a significant reduction in hospitalization for severe OHSS after an intention to treat analysis was performed.

  1. Incidence, risk factors, clinico-microbiological profile, change in ventilator settings needed and outcome of 135 ventilator associated pneumonia cases in pediatric intensive care unit (PICU of a tertiary care centre in Eastern India

    Directory of Open Access Journals (Sweden)

    Manonita Manjhi

    2018-02-01

    Full Text Available Introduction: Ventilator associated pneumonia (VAP is the second most common nosocomial infection diagnosed in mechanically ventilated patients with incidence of 20-36%, mainly caused by Gram-negative organisms in our country. Decrease in PaO2/FIO2 (arterial oxygen tension/fractional inspired oxygen is an early marker of VAP. Impaired consciousness, re-intubation and continuous sedation are the most important risk factors of VAP. We aimed to study the incidence, risk factors, clinico-microbiological profile, change in ventilator settings needed and outcome of VAP in the pediatric intensive care unit (PICU of a tertiary care centre in Eastern India.Methods: This retrospective, observational study was conducted from January 2015 to June 2017, including 300 patients. We diagnosed VAP using Centre for Disease Control and Prevention (CDC criteria and analysed the data using the Statistical Package for Social Sciences (SPSS® version 20.0.Results: Incidence of VAP was 45%, with higher incidence in infants with prolonged ventilation, use of continuous sedation and H2 blockers, re-intubation, presence of genetic syndromes and impaired consciousness. Gram-negative organisms (94% (P. aeruginosa [45.93%], K. pneumoniae [25.18%], E. coli [14.81%], Acinetobacter spp. [8.14%] outnumbered Gram-positive organisms (6% (S. aureus [2.96%], Enterococcus spp. [2.22%] and S. pneumoniae [0.7%]. Resistance to common antibiotics was found in many cases. Multivariate analysis identified nasogastric tube feeding (adjusted odds ratio [OR] = 1.88; 95% CI = 0.8-2.3, use of H2-blockers (adjusted OR = 2.04; 95% CI = 0.51-4.5, use of continuous sedation (adjusted OR = 2.779; 95% CI = 0.7-4.9, re-intubation (adjusted OR = 4.861; 95% CI = 1.6-17.8 and duration of ventilation > 1 week (adjusted OR = 5; 95% CI = 0.7-6.3 as the risk factors for VAP. Purulent tracheal secretions (p < 0.0001, positive tracheal aspirate culture (p < 0.0001 and a suggestive chest radiograph (p < 0

  2. The potential of high intensity focused ultrasound (HIFU) combine phase-sensitive optical coherence tomography (PhS-OCT) for diseases diagnosis, treatment and monitoring

    Science.gov (United States)

    Zhou, Kanheng; Wang, Yan; Feng, Kairui; Li, Chunhui; Huang, Zhihong

    2018-02-01

    HIFU is a truly noninvasive, acoustic therapeutic technique that utilizes high intensity acoustic field in the focus to kill the targeted tissue for disease treatment purpose. The mechanical properties of targeted tissue changes before and after treatment, and this change can be accurately detected by shear wave elastography. Hence, shear wave elastography is usually used for monitoring HIFU treatment asynchronously. To improve the low spatial resolution in ultrasound shear wave elastography, and to perform diseases diagnosis, treatment and monitoring in the same system, a new setup that combines HIFU and PhS-OCT system was proposed in this study. This proposed setup could do 1) HIFU treatment when the transducer works at high energy level, 2) ultrasound induced shear wave optical coherence elastography for HIFU treatment asynchronous monitoring when the transducer works at low energy level. Ex-vivo bovine liver tissue was treated at the same energy level for different time (0s, 1s, 5s, 9s) in this research. Elastography was performed on the lesion area of the sample after HIFU treatment, and the elastogram was reconstructed by the time of flight time method. The elastogram results clearly show the boundary of HIFU lesion area and surrounding normal tissue, even for 1s treatment time. And the average elasticity of the lesion grows linearly as the treatment time increases. Combined with OCT needle probe, the proposed method has a large potential not only to be used for superficial diseases treatment, but also to be used for high-precision-demanded diseases treatment, e.g. nervous disease treatment.

  3. Optimization of electro-optic phase shifters for integrated optical phased arrays

    Science.gov (United States)

    Macik, Dwayne D.; Bravo, Tyler E.; Pentecost, Seeley M.; Espinal, Francisco A.; Madsen, Christi K.

    2017-05-01

    A low-loss, high-speed optical phased array (OPA) has been designed and fabricated. Two different platforms have been utilized in combination to leverage electro-optic (EO) tuning. A lithium niobate (LiNbO3) optical phased array was fabricated and used in conjunction with a silicon nitride (Si3N4) 8x8 waveguide array that condenses the output pitch and utilizes the TriplexTM waveguide technology. This OPA allows for the non-mechanical beam steering (NMBS) of 1550 nm light on an edge coupled optic platform and takes advantage of the high electro-optic coefficient and high speed capability of LiNbO3 for electro-optic phase tuning. This coupled OPA has an overall insertion loss of 3.5 dB which is advantageous to silicon-on-insulator OPAs that have shown overall insertion losses of 14 dB. To characterize and tune this device, a 3 lens imaging system was employed to produce both near- and far- field intensity patterns of the output of the OPA on a static image plane. At the image plane, a high resolution infrared camera was used to observe the resulting intensity pattern. The control software for tuning the OPA reads the intensity incident at a specified position on the detector array, and has a PWM interface to drive the electro-optic phase controls. Beam steering was accomplished using an iterative tuning algorithm.

  4. Self-Induced Backaction Optical Pulling Force

    Science.gov (United States)

    Zhu, Tongtong; Cao, Yongyin; Wang, Lin; Nie, Zhongquan; Cao, Tun; Sun, Fangkui; Jiang, Zehui; Nieto-Vesperinas, Manuel; Liu, Yongmin; Qiu, Cheng-Wei; Ding, Weiqiang

    2018-03-01

    We achieve long-range and continuous optical pulling in a periodic photonic crystal background, which supports a unique Bloch mode with the self-collimation effect. Most interestingly, the pulling force reported here is mainly contributed by the intensity gradient force originating from the self-induced backaction of the object to the self-collimation mode. This force is sharply distinguished from the widely held conception of optical tractor beams based on the scattering force. Also, this pulling force is insensitive to the angle of incidence and can pull multiple objects simultaneously.

  5. Reflective optics

    CERN Document Server

    Korsch, Dietrich

    1991-01-01

    This is the first book dedicated exclusively to all-reflective imaging systems. It is a teaching tool as well as a practical design tool for anyone who specializes in optics, particularly for those interested in telescopes, infrared, and grazing-incidence systems. The first part of the book describes a unified geometric optical theory of all-reflective imaging systems (from near-normal to grazing incidence) developed from basic principles. The second part discusses correction methods and a multitude of closed-form solutions of well-corrected systems, supplemented with many conventional and unc

  6. Near-Field Optical Microscopy of Fractal Structures

    DEFF Research Database (Denmark)

    Coello, Victor; Bozhevolnyi, Sergey I.

    1999-01-01

    Using a photon scanning tunnelling microscope combined with a shear-force feedback system, we image both topographical and near-field optical images (at the wavelengths of 633 and 594 nm) of silver colloid fractals. Near-field optical imaging is calibrated with a standing evanescent wave pattern....... Near-field optical images exhibit spatially localized (within 150-250 nm) intensity enhancement (by up to 20 times) in the form of round bright spots, whose positions and brightness are found to be sensitive to the light wavelength, polarization and angle of incidence. The observed phenomenon...

  7. A particle-in-cell plus Monte Carlo study of plasma-induced damage of normal incidence collector optics used in extreme ultraviolet lithography

    NARCIS (Netherlands)

    Wieggers, R. C.; W. J. Goedheer,; M.R. Akdim,; F. Bijkerk,; Zegeling, P. A.

    2008-01-01

    We present a kinetic simulation of the plasma formed by photoionization in the intense flux of an extreme ultraviolet lithography (EUVL) light source. The model is based on the particle-in-cell plus Monte Carlo approach. The photoelectric effect and ionization by electron collisions are included.

  8. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  9. The effects of the intense laser field on the nonlinear optical properties of a cylindrical Ga{sub 1−x}Al{sub x}As/GaAs quantum dot under applied electric field

    Energy Technology Data Exchange (ETDEWEB)

    Kasapoglu, E., E-mail: ekasap@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Duque, C.A. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mora-Ramos, M.E. [Centro de Investigación en Ciencias, Instituto de Ciencias Básicas y Aplicadas, Universidad Autóonoma del Estado de Morelos, Av. Universidad 1001, CP 62209 Cuernavaca, Morelos (Mexico); Sökmen, I. [Department of Physics, Dokuz Eylül University, 35160 Buca, İzmir (Turkey)

    2015-10-01

    In the present work, the effects of the intense laser field on total optical absorption coefficient (the linear and third-order nonlinear) and total refractive index change (the linear and third-order nonlinear) for transitions between different intersubbands in the Ga{sub 1−x}Al{sub x}As/GaAs cylindrical quantum dot under external electric field are investigated. The calculations were performed within the compact density-matrix formalism with the use of the effective mass approximation. The obtained results show that both total absorption coefficient and refractive index change are sensitive to the electric and intense laser fields. By changing the intensities of the electric and laser fields, we can obtain the blue or red shift, without the need for the growth of many different samples. - Highlights: • The effects of the non-resonant intense laser field and electric field on the nonlinear optical properties of cylindrical quantum dot are investigated. • The both total absorption coefficient and refractive index change are sensitive to dot dimensions and the effects of external fields. • By changing the external fields together with dot dimensions a blue or red shift can be obtained.

  10. Incidência de insuficiência renal aguda na Unidade de Terapia Intensiva Neonatal de um hospital paulista Incidencia de insuficiencia renal crónica aguda en la Unidad de Cuidados Intensivos Neonatal de un hospital de Sao Paulo Incidence of acute renal failure in the Neonatal Intensive Care Unit of a hospital in São Paulo

    Directory of Open Access Journals (Sweden)

    Renato Ribeiro Nogueira Ferraz

    2009-01-01

    .OBJECTIVES: To describe the incidence of acute renal failure (ARF in the neonatal intensive care unit (NICU of a hospital in São Paulo and to verify the use of the "risk of renal failure, injury to the kidney, failure of kidney function, loss of kidney function and end-stage renal failure (RIFLE" classification for the allocation of the neonates. METHODS: Review of medical records of neonates from April 4 to April 25, 2008. RESULTS: Of the 19 admissions in the NICU, 10% were diagnosed as ARF according to the RIFLE classification. The neonates diagnosed with ARF were referred to the dialysis service. CONCLUSION: Although this study had a very small sample size, the findings indicate that ARF represents 10% of the primary diagnosis among our sample of neonates admitted to the NICU. Large and longer studies are necessary to evaluate the incidence of ARF in the NICU.

  11. Optical fibres sensor based in the intensity switch of a linear laser with two Bragg gratings; Sensor de fibra optica basado en el salto de intensidad de un laser lineal con dos rejillas de Bragg

    Energy Technology Data Exchange (ETDEWEB)

    Basurto P, M.A.; Kuzin, E.A.; Archundia B, C.; Marroquin, E.; May A, M.; Cerecedo N, H.H.; Sanchez M, J.J. [Departamento de Fotonica y Fisica Optica, Instituto Nacional de Astrofisica, Optica y Electronica (INAOE). Apartado Postal 51 y 216, 72000 Puebla (Mexico); Tentori S, D.; Marquez B, I.; Shliagin, M.; Miridonov, S. [Centro de Investigacion CESE (Mexico)

    2000-07-01

    In this work we propose a new configuration for an optical fiber temperature sensor, based on a linear type Er-doped fiber laser. The laser cavity consists of an Er-doped fiber and two identical Bragg gratings at the fiber ends (working as reflectors). Temperature changes are detected by measuring, through one of the gratings, the intensity variations atthe system's output. When the temperature of one of the Bragg gratings is modified, a wavelength shift of its spectral reflectivity is observed. Hence, the laser emission intensity of the system is modified. We present experimental results of the intensity switch observed when the temperature difference between the gratings detunes their spectral reflectance. Making use of this effect it is possible to develop limit comparators to bound the temperature range for the object under supervision. This limiting work can be performed with a high sensitivity using a very simple interrogation procedure. (Author)

  12. Optical Computing With Nonlinear Optics

    Science.gov (United States)

    Khitrova, Galina; Gibbs, Hyatt; Peyghambarian, Nasser

    1987-01-01

    Nonlinear optics is becoming a new thrust in the field of optical computing and signal processing.14 Optical nonlinearity makes the device's transmission intensity dependent, so one can obtain the thresholding needed for logic decisionmaking. Thresholding is essential to digital optical computing, neural nets, and associative memories. GaAs etalons exhibit many of the characteristics desirable for the nonlinear devices including high speed (picosecond) and diode-laser compatability. However, demonstrations of the use of nonlinear decisionmaking for optical computing have used ZnS or ZnSe interference filters. They are slow (millisecond), but they can be used with the visible 514.5-nm output of an argon laser. We have used such filters to demonstrate all-optical logic operations, one-bit addition by symbolic substitution, and recognition of a three-spot pattern in an arbitrary 2 x 8 array of input beams. The application to associative memories is under study.

  13. Grazing incidence beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.

    1985-01-01

    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  14. Computer generated holography with intensity-graded patterns

    Directory of Open Access Journals (Sweden)

    Rossella Conti

    2016-10-01

    Full Text Available Computer Generated Holography achieves patterned illumination at the sample plane through phase modulation of the laser beam at the objective back aperture. This is obtained by using liquid crystal-based spatial light modulators (LC-SLMs, which modulate the spatial phase of the incident laser beam. A variety of algorithms are employed to calculate the phase modulation masks addressed to the LC-SLM. These algorithms range from simple gratings-and-lenses to generate multiple diffraction-limited spots, to iterative Fourier-transform algorithms capable of generating arbitrary illumination shapes perfectly tailored on the base of the target contour. Applications for holographic light patterning include multi-trap optical tweezers, patterned voltage imaging and optical control of neuronal excitation using uncaging or optogenetics. These past implementations of computer generated holography used binary input profile to generate binary light distribution at the sample plane. Here we demonstrate that using graded input sources, enables generating intensity graded light patterns and extend the range of application of holographic light illumination. At first, we use intensity-graded holograms to compensate for LC-SLM position dependent diffraction efficiency or sample fluorescence inhomogeneity. Finally we show that intensity-graded holography can be used to equalize photo evoked currents from cells expressing different level of chanelrhodopsin2 (ChR2, one of the most commonly used optogenetics light gated channels, taking into account the non-linear dependence of channel opening on incident light.

  15. 20040217 NATO Advanced Research Workshop on Quasi-Optical Control of Intense Microwave Transmission Nizhny Novgorod, Russia 17 - 20 Feb 2004 2004 novgorod20040217 20040220

    CERN Document Server

    Hirshfield, Jay L

    2005-01-01

    This volume assembles the texts of presentations given at the NATO-sponsored Advanced Research Workshop on Quasi-Optical Transmission of High-Power Microwaves, held in Nizhny Novgorod, Russia in February 2004. The presentations bridge a wide range of technical areas, but share common tools of analysis and design. Applications of quasi-optics extend to the use of high-power microwaves—including millimeter-waves— for radar and communications (especially deep space millimeter-wave systems, space debris detection radar, and radar for the detection of small targets moving over heavy clutter); particle accelerators (especially for a future high-acceleration-gradient electron-positron collider); plasma research (especially for controlled nuclear fusion and waste decontamination); and material processing (in particular, ceramic sintering with millimeter-waves, and the coating of metal surfaces with protective dielectric films.). Scientists and engineers working in any of these areas should benefit significantly f...

  16. Corneal injuries: incidence and risk factors in the Intensive Care Unit Lesiones en la córnea: incidencia y factores de riesgo en Unidad de Terapia Intensiva Lesões na córnea: incidência e fatores de risco em Unidade de Terapia Intensiva

    Directory of Open Access Journals (Sweden)

    Andreza Werli-Alvarenga

    2011-10-01

    Full Text Available Patients hospitalized in the Intensive Care Unit (ICU may present risk for corneal injury due to sedation or coma. This study aimed to estimate the incidence of corneal injuries; to identify the risk factors and to propose a risk prediction model for the development of corneal injury, in adult patients, in an intensive care unit of a public hospital. This is a one year, prospective cohort study with 254 patients. The data were analyzed using descriptive statistics, univariate and logistic regression. Of the 254 patients, 59.4% had corneal injuries and the mean time to onset was 8.9 days. The independent variables that predispose to risk for punctate type corneal injury were: duration of hospitalization, other ventilatory support device, presence of edema and blinking less than five times a minute. The Glasgow Coma Scale and exposure of the ocular globe were the variables related to corneal ulcer type corneal injury. The injury frequencies were punctate type (55.1% and corneal ulcers (11.8%. Risk prediction models for the development of punctate and corneal ulcer type corneal injury were established.Pacientes internados en Unidad de Terapia Intensiva (UTI pueden presentar riesgo de lesión en la córnea debido a la sedación o al coma. Este estudio tuvo por objetivo estimar la incidencia de las lesiones en la córnea; identificar los factores de riesgo y proponer un modelo de predicción de riesgo para el desarrollo de lesión en la córnea, en pacientes adultos, en Unidad de Terapia Intensiva, de un hospital público. Estudio de cohorte prospectivo de un año con 254 pacientes. Los datos fueron analizados por estadística descriptiva, univariada y de regresión logística. De los 254 pacientes, 59,4% tuvieron lesión en la córnea y el tiempo promedio para su aparición fue de 8,9 días. Las variables independientes que predisponen al riesgo de lesión en la córnea tipo punteada fueron: tiempo de internación, otro dispositivo de asistencia

  17. Influence of noise amplification on generation of regular short pulse trains in optical fibre pumped by intensity-modulated CW radiation.

    Science.gov (United States)

    Kobtsev, Sergey M; Smirnov, Sergey V

    2008-05-12

    For the first time the influence of noise amplification on decay of modulated continuous-wave pumping into a pulse series in an optical fiber is considered. Dependence of noise-to-signal ratio in pulse train at fibre exit on initial modulation depth obtained both analytically and by means of numerical simulations. The minimum modulation frequency is estimated which leads to a regular pulse train formation from CW pumping.

  18. Optical particle trapping and dynamic manipulation using spatial light modulation

    DEFF Research Database (Denmark)

    Eriksen, René Lynge

    This thesis deals with the spatial phase-control of light and its application for optical trapping and manipulation of micron-scale objects. Utilizing the radiation pressure, light exerts on dielectric micron-scale particles, functionality of optical tweezers can be obtained. Multiple intensity...... spots acting as tweezers beams are generated using phase-only spatial light modulation of an incident laser beam together with a generalized phase contrast (GPC) filter. The GPC method acts as a common-path interferometer, which converts encoded phase information into an appropriate intensity pattern...... suitable for optical trapping. A phaseonly spatial light modulator (SLM) is used for the phase encoding of the laser beam. The SLM is controlled directly from a standard computer where phase information is represented as gray-scale image information. Experimentally, both linear and angular movements...

  19. Time-dependent scattering of incident light of various wavelengths in ferrofluids under external magnetic field

    Science.gov (United States)

    Jin, Jingyu; Song, Dongxing; Geng, Jiafeng; Jing, Dengwei

    2018-02-01

    Ferrofluids can exhibit the anisotropic thermodynamic properties under magnetic fields. The dynamic optical properties of ferrofluids in the presence of magnetic fields are of particular interest due to their potential application as various optical devices. Although time-dependent light scattering by ferrofluids have been extensively studied, the effect of wavelength of incident light have been rarely considered. Here, for the first time, we investigated both the time- and wavelength-dependent light scattering in water based ferrofluids containing Fe3O4 nanoparticles under an external magnetic field. The field-induced response behavior of the prepared ferrofluid samples was determined and verified first by thermal conductivity measurement and numerical simulation. Double-beam UV-Vis spectrophotometer was employed to record the temporal evolution of transmitted intensity of incident light of various wavelengths passing through the ferrofluid sample and propagating parallel to the applied field. As expected, the light intensity decreases to a certain value right after the field is turned on due to the thermal fluctuation induced disorder inside the flexible particle chains. Then the light intensity further decreases with time until the appearance of a minimum at time τ0 followed by an inversed increase before finally reaches equilibrium at a particular time. More importantly, the characteristic inversion time τ0 was found to follow a power law increase with the wavelength of incident light (τ0 ∼ λα, where α = 2.07). A quantitative explanation for the wavelength dependence of characteristic time was proposed based on the finite-difference time-domain (FDTD) method. The simulation results are in good agreement with our experimental observations. The time-dependent light scattering in ferrofluids under different incident wavelengths was rationalized by considering both the coarsening process of the particle chains and the occurrence of resonance within the

  20. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  1. Method and apparatus of highly linear optical modulation

    Science.gov (United States)

    DeRose, Christopher; Watts, Michael R.

    2016-05-03

    In a new optical intensity modulator, a nonlinear change in refractive index is used to balance the nonlinearities in the optical transfer function in a way that leads to highly linear optical intensity modulation.

  2. The impact of an education program on hand hygiene compliance and nosocomial infection incidence in an urban neonatal intensive care unit: an intervention study with before and after comparison

    NARCIS (Netherlands)

    Helder, Onno K.; Brug, Johannes; Looman, Caspar W. N.; van Goudoever, Johannes B.; Kornelisse, René F.

    2010-01-01

    Nosocomial bloodstream infections are a major cause of morbidity and mortality in neonatal intensive care units. Appropriate hand hygiene is singled out as the most important measure in preventing these infections. However, hand hygiene compliance among healthcare professionals remains low despite

  3. Quality difference of neointima following the implantation of bioresorbable scaffold and metallic stent in patients with ST elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coherence tomography in TROFI II trial.

    Science.gov (United States)

    Sotomi, Yohei; Onuma, Yoshinobu; Liu, Shengnan; Asano, Taku; Eggermont, Jeroen; Katagiri, Yuki; Cavalcante, Rafael; de Winter, Robbert J; Wykrzykowska, Joanna J; Brugaletta, Salvatore; Räber, Lorenz; Sabaté, Manel; Windecker, Stephan; Dijkstra, Jouke; Serruys, Patrick W

    2018-02-27

    We aimed to assess possible difference of the neointimal quality after everolimus-eluting bioresorbable scaffold (BVS) implantation in comparison with cobalt chromium everolimus-eluting scaffold (CoCr-EES) by optical frequency domain imaging (OFDI). This study is a post-hoc analysis of TROFI II trial assessing neointimal quality 6-month after the implantation of BVS(N=82) and CoCr-EES(N=87) in STEMI patients. Neointimal light property analysis by OFDI full-automatically computed light attenuation, backscatter and light intensity for superficial and deep neointima. High light attenuation/backscatter and high light intensity are reportedly associated with lipidic change and tissue maturation, respectively. Superficial and deep neointima in BVS presented lower light attenuation than CoCr-EES (superficial:0.77±0.15 vs. 1.27±0.55mm-1, p<0.001; deep:0.88±0.20 vs. 1.17±0.27mm-1, p<0.001). Superficial neointima in BVS showed comparable backscatter to that of CoCr-EES (4.81±0.52 vs. 4.94±0.61, p=0.141), while deep neointima in BVS showed lower backscatter than that of CoCr-EES (4.60±0.62 vs. 4.97±0.62, p<0.001). Light intensity of superficial neointima was comparable between both arms (139±13 vs. 144±30, p=0.236), whereas light intensity of deep neointima in BVS was lower than CoCr-EES (129±14 vs. 138±21, p<0.001). The present OFDI comparison suggested that tissue maturation was comparable but lipidic change of neointima was less prominent after the BVS implantation than CoCr-EES.

  4. Methods for globally treating silica optics to reduce optical damage

    Science.gov (United States)

    Miller, Philip Edward; Suratwala, Tayyab Ishaq; Bude, Jeffrey Devin; Shen, Nan; Steele, William Augustus; Laurence, Ted Alfred; Feit, Michael Dennis; Wong, Lana Louie

    2012-11-20

    A method for preventing damage caused by high intensity light sources to optical components includes annealing the optical component for a predetermined period. Another method includes etching the optical component in an etchant including fluoride and bi-fluoride ions. The method also includes ultrasonically agitating the etching solution during the process followed by rinsing of the optical component in a rinse bath.

  5. Highlights from 4STAR Sky-Scanning Retrievals of Aerosol Intensive Optical Properties from Multiple Field Campaigns with Detailed Comparisons of SSA Reported During SEAC4RS

    Science.gov (United States)

    Flynn, C. J.; Dahlgren, R. P.; Dunagan, S. E.; Johnson, R. R.; Kacenelenbogen, M. S.; LeBlanc, S. E.; Livingston, J. M.; Redemann, J.; Schmid, B.; Segal-Rosenhaimer, M.; Shinozuka, Y.; Zhang, Q.; Schmidt, S.; Holben, B. N.; Sinyuk, A.; Hair, J. W.; Anderson, B. E.; Ziemba, L. D.

    2015-12-01

    The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument combines airborne sun tracking capabilities of the Ames Airborne Tracking Sun Photometer (AATS-14) with AERONET-like sky-scanning capability and adds state-of-the-art fiber-coupled grating spectrometry to yield hyperspectral measurements of direct solar irradiance and angularly resolved sky radiance. The combination of sun-tracking and sky-scanning capability enables retrievals of wavelength-dependent aerosol optical depth (AOD), mode-resolved aerosol size distribution (SD), asphericity, and complex refractive index, and thus also the scattering phase function, asymmetry parameter, single-scattering albedo (SSA), and absorption aerosol optical thickness (AAOT). From 2012 to 2014 4STAR participated in four major field campaigns: the U.S. Dept. of Energy's TCAP I & II campaigns, and NASA's SEAC4RS and ARISE campaigns. Establishing a strong performance record, 4STAR operated successfully on all flights conducted during each of these campaigns. Sky radiance spectra from scans in either constant azimuth (principal plane) or constant zenith angle (almucantar) were interspersed with direct beam measurements during level legs. During SEAC4RS and ARISE, 4STAR airborne measurements were augmented with flight-level albedo from the collocated Shortwave Spectral Flux Radiometer (SSFR) providing improved specification of below-aircraft radiative conditions for the retrieval. Calibrated radiances and retrieved products will be presented with particular emphasis on detailed comparisons of ambient SSA retrievals and measurements during SEAC4RS from 4STAR, AERONET, HSRL2, and from in situ measurements.

  6. Quantum optics

    International Nuclear Information System (INIS)

    Flytzanis, C.

    1988-01-01

    The 1988 progress report of the Quantum Optics laboratory (Polytechnic School, France) is presented. The research program is focused on the behavior of dense and dilute materials submitted to short and high-intensity light radiation fields. Nonlinear optics techniques, with time and spatial resolution, are developed. An important research activity concerns the investigations on the interactions between the photon beams and the inhomogeneous or composite materials, as well as the artificial microstructures. In the processes involving molecular beams and surfaces, the research works on the photophysics of surfaces and the molecule-surface interactions, are included [fr

  7. Introduction to nonimaging optics

    CERN Document Server

    Chaves, Julio

    2015-01-01

    Introduction to Nonimaging Optics covers the theoretical foundations and design methods of nonimaging optics, as well as key concepts from related fields. This fully updated, revised, and expanded Second Edition: Features a new and intuitive introduction with a basic description of the advantages of nonimaging opticsAdds new chapters on wavefronts for a prescribed output (irradiance or intensity), infinitesimal étendue optics (generalization of the aplanatic optics), and Köhler optics and color mixingIncorporates new material on the simultaneous multiple surface (SMS) design method in 3-D, int

  8. EUV optics in photoionization experiments

    Science.gov (United States)

    Bartnik, Andrzej; Wachulak, Przemysław; Fiedorowicz, Henryk; Fok, Tomasz; Jarocki, Roman; Kostecki, Jerzy; Szczurek, Anna; Szczurek, Mirosław; Pina, Ladislav; Sveda, Libor

    2013-05-01

    In this work photoionized plasmas were created by irradiation of He, Ne and Ar gases with a focused EUV beam from one of two laser-plasma sources employing Nd:YAG laser systems of different parameters. First of them was a 10-Hz laser-plasma EUV source, based on a double-stream gas-puff target, irradiated with the 3-ns/0.8J laser pulse. EUV radiation in this case was focused using a gold-plated grazing incidence ellipsoidal collector in the wavelength range λ = 9÷70 nm. The most intense emission was in the relatively narrow spectral region centred at λ = 11 +/- 1 nm. The second source was based on a 10 ns/10 J/10 Hz laser system. In this case EUV radiation was focused using a gold-plated grazing incidence multifoil collector or a Mo-coated ellipsoidal collector. The most intense emission in this case was in the 5 ÷ 15 nm spectral region. Radiation fluence ranged from 60 mJ/cm2 to 400 mJ/cm2. Different gases were injected into the interaction region, perpendicularly to an optical axis of the irradiation system, using an auxiliary gas puff valve. Irradiation of the gases resulted in ionization and excitation of atoms and ions. Spectra in EUV range were measured using a grazing incidence, flat-field spectrometer (McPherson Model 251), equipped with a 450 lines/mm toroidal grating. In all cases the most intense emission lines were assigned to singly charged ions. The other emission lines belong to atoms or doubly charged ions. The spectra were excited in low density gases of the order of 1 ÷ 10% atmospheric density.

  9. Efficient optical trapping of CdTe quantum dots by femtosecond laser pulses

    KAUST Repository

    Chiang, Weiyi

    2014-12-11

    The development in optical trapping and manipulation has been showing rapid progress, most of it is in the small particle sizes in nanometer scales, substituting the conventional continuous-wave lasers with high-repetition-rate ultrashort laser pulse train and nonlinear optical effects. Here, we evaluate two-photon absorption in optical trapping of 2.7 nm-sized CdTe quantum dots (QDs) with high-repetition-rate femtosecond pulse train by probing laser intensity dependence of both Rayleigh scattering image and the two-photon-induced luminescence spectrum of the optically trapped QDs. The Rayleigh scattering imaging indicates that the two-photon absorption (TPA) process enhances trapping ability of the QDs. Similarly, a nonlinear increase of the two-photon-induced luminescence with the incident laser intensity fairly indicates the existence of the TPA process.

  10. Investigations on magnetic field induced optical transparency in magnetic nanofluids

    Science.gov (United States)

    Mohapatra, Dillip Kumar; Philip, John

    2018-02-01

    We study the magnetic field induced optical transparency and its origin in magnetic nanoemulsion of droplets of average size ∼200 nm containing superparamagnetic iron oxide nanoparticles. Beyond a certain volume fraction (Φ > 0.0021) of magnetic nanoemulsion and a critical magnetic field (Hc1), the transmitted light intensity increases drastically and reaches a maximum at another critical magnetic field (Hc2), beyond which the transmitted light intensity decreases and reaches a plateau. Interestingly, the transmitted light intensity at Hc2 is found to increase linearly with Φ and the critical magnetic fields Hc1 and Hc2 follow power law decay with Φ (i.e. Hc ∼ Φ-x), with exponents 0.48 and 0.27, respectively. The light intensity recovers to its initial value when the magnetic field is switched off, indicating the perfect reversibility of the field induced transparency process. The observed straight line scattered patterns above Hc2, on a screen placed perpendicular to the incident beam, confirms the formation of rod like anisotropic nanostructures perpendicular to the direction of light propagation. The magneto-optical measurements in the emulsion confirm that the observed field induced transparency in magnetic emulsions for Φ > 0.0021 is due to the optical birefringence caused by the rod like nanostructures. The reduced birefringence is found to be proportional to the square of the applied magnetic field. This finding offers several possibilities in using magnetic nanofluids in tunable optical devices.

  11. Linear and nonlinear intraband optical properties of ZnO quantum dots embedded in SiO2 matrix

    Directory of Open Access Journals (Sweden)

    Deepti Maikhuri

    2012-03-01

    Full Text Available In this work we investigate some optical properties of semiconductor ZnO spherical quantum dot embedded in an amorphous SiO2 dielectric matrix. Using the framework of effective mass approximation, we have studied intraband S-P, and P-D transitions in a singly charged spherical ZnO quantum dot. The optical properties are investigated in terms of the linear and nonlinear photoabsorption coefficient, the change in refractive index, and the third order nonlinear susceptibility and oscillator strengths. Using the parabolic confinement potential of electron in the dot these parameters are studied with the variation of the dot size, and the energy and intensity of incident radiation. The photoionization cross sections are also obtained for the different dot radii from the initial ground state of the dot. It is found that dot size, confinement potential, and incident radiation intensity affects intraband optical properties of the dot significantly.

  12. pH-dependent optical properties of N-acetyl-L-cysteine-capped ZnSe(S) nanocrystals with intense/stable emissions

    Energy Technology Data Exchange (ETDEWEB)

    Soheyli, Ehsan [University of Arak, Department of Physics, Faculty of Science (Iran, Islamic Republic of); Sahraei, Reza, E-mail: r.sahraei@ilam.ac.ir [University of Ilam, Department of Chemistry, Faculty of Science (Iran, Islamic Republic of); Nabiyouni, Gholamreza [University of Arak, Department of Physics, Faculty of Science (Iran, Islamic Republic of)

    2017-03-15

    In the present study, a series of aqueous-based ZnSe(S) nanocrystals (NCs) was prepared at different solution pH ranging from 8 to 11.9, and using N-acetyl-L-cysteine (NAC) as capping agent. In addition to zinc blende structure, the X-ray diffraction studies demonstrated the quantum size regime of the ZnSe(S) NCs. To gain further insight toward the influence of the quantum confinement and pH values on optical properties of the as-prepared NCs, their UV-visible absorption and photoluminescence spectra were systematically analyzed. The absorption spectra experienced a red shift from ~340 to ~382 nm as the pH increased from 8.0 to 11.9, indicating the growth of the as-prepared ZnSe(S) NCs. The emission spectra also show the obvious red shift and the relative area of excitonic to trap emission, firstly increases from pH = 8.0 to 10.7, and then decreases by further increasing of the solution pH. The initial behavior might be due to the improved surface passivation of the trap dangling states by better deprotonation of thiol groups in NAC, whereas at pH >10.7, the faster growth rate of the ZnSe(s) NCs may lead to the formation of many defect sites. All of these phenomena were combined in the scheme which displays the effect of quantum confinement and solution pH on variation of the excitonic and trap-related emissions.

  13. Sound intensity

    DEFF Research Database (Denmark)

    Crocker, Malcolm J.; Jacobsen, Finn

    1998-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  14. Sound Intensity

    DEFF Research Database (Denmark)

    Crocker, M.J.; Jacobsen, Finn

    1997-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  15. Optical design of a LED searchlight system

    Science.gov (United States)

    Gong, Chen; Xu, Haiping; Liang, Jinhua; Liu, Yunfei; Yuan, Zengquan

    2018-01-01

    A 1200m visible searchlight system is designed based on photometry and application of geometric optics. To generate intensity distribution of this relatively powerful light beam we propose to use a high power LED and several refractive optical elements, which are composed of two plane-convex lenses and a conventional Fresnel lens. Two plane-convex lenses enable refraction of the side rays from the LED to the front direction which incident on the Fresnel lens. Fresnel lens, in its turn, concentrate the light flux and provide a nearly collimated beam to meet the requirement of forming a well-illuminated area across the road in the far field. Simulation data shows that this searchlight allow generating an appropriate illumination distribution for the long range requirements. A proof-of-concept prototype producing acceptable illuminance is developed.

  16. Holographic Optical Data Storage

    Science.gov (United States)

    Timucin, Dogan A.; Downie, John D.; Norvig, Peter (Technical Monitor)

    2000-01-01

    Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising

  17. In situ sound absorption measurement: investigations on oblique incidence

    NARCIS (Netherlands)

    Kuipers, E.R.; Wijnant, Ysbrand H.; de Boer, Andries; Klemenz, M.

    2012-01-01

    A novel method for the measurement of sound absorption has been developed. By assuming that, in a single point, the sound field consists of an incident- and a reflected plane wave, the locally incident- and reflected intensities can be determined. To this purpose, the active intensity and the sum of

  18. Third order nonlinear optics in Ag nanocubes: local and nonlocal optical responses as a function of excitation wavelength and particle size.

    Science.gov (United States)

    García Ramírez, E V; Sabinas Hernández, S A; Ramírez Martínez, D; Díaz, G; Reyes Esqueda, J A

    2017-12-11

    Colloidal silver nanocubes in solution were analyzed by the Z-scan technique in the resonant and non-resonant regimes. Three different systems with particle sizes of 56, 99 and 215 nm, and concentrations of 0.378, 0.831 and 0.715 mg/mL, respectively, were obtained by the polyol method. Nonlinear excitation of the samples was performed with laser pulses of 26 ps, at a repetition rate of 10 Hz, and using three different wavelenghts (355, 532 and 1064 nm), exciting only the electronic part of the optical nonlinearity, and avoiding induced thermal loading of the samples. Whenever observable, samples showed saturable absorption for all wavelengths, which was dependent, in general, on concentration and incident intensity. For samples featuring sizes of 55 and 99 nm, saturable absorption could be observed for wavelengths close to their dipolar surface plasmon resonances; while, for samples with sizes of 99 and 215 nm, saturable absorption and positive nonlinear optical refraction (only for size of 215 nm) could be observed at 1064 nm. Besides, for some samples, nonlinear optical response followed the incident intensity profile at wavelengths close to resonance. On the contrary, for wavelengths out of resonance, the nonlinear optical behavior showed to be nonlocal, ie, its profile was narrower than the incident one.

  19. Combined holographic-mechanical optical tweezers: Construction, optimization, and calibration

    Science.gov (United States)

    Hanes, Richard D. L.; Jenkins, Matthew C.; Egelhaaf, Stefan U.

    2009-08-01

    A spatial light modulator (SLM) and a pair of galvanometer-mounted mirrors (GMM) were combined into an optical tweezers setup. This provides great flexibility as the SLM creates an array of traps, which can be moved smoothly and quickly with the GMM. To optimize performance, the effect of the incidence angle on the SLM with respect to phase and intensity response was investigated. Although it is common to use the SLM at an incidence angle of 45°, smaller angles give a full 2π phase shift and an output intensity which is less dependent on the magnitude of the phase shift. The traps were calibrated using an active oscillatory technique and a passive probability distribution method.

  20. Combined holographic-mechanical optical tweezers: Construction, optimization, and calibration

    International Nuclear Information System (INIS)

    Hanes, Richard D. L.; Jenkins, Matthew C.; Egelhaaf, Stefan U.

    2009-01-01

    A spatial light modulator (SLM) and a pair of galvanometer-mounted mirrors (GMM) were combined into an optical tweezers setup. This provides great flexibility as the SLM creates an array of traps, which can be moved smoothly and quickly with the GMM. To optimize performance, the effect of the incidence angle on the SLM with respect to phase and intensity response was investigated. Although it is common to use the SLM at an incidence angle of 45 deg., smaller angles give a full 2π phase shift and an output intensity which is less dependent on the magnitude of the phase shift. The traps were calibrated using an active oscillatory technique and a passive probability distribution method.

  1. Breast cancer incidence in Mongolia

    Science.gov (United States)

    Altantsetseg, Dalkhjav; Davaasambuu, Ganmaa; Rich-Edwards, Janet; Davaalkham, Dambadarjaa; Tretli, Steinar; Hoover, Robert N.; Frazier, A. Lindsay

    2013-01-01

    Purpose Data on international variation in breast cancer incidence may help to identify additional risk factors. Substantially lower breast cancer rates in Asia than in North America and Western Europe are established, but differences within Asia have been largely ignored despite heterogeneity in lifestyles and environments. Mongolia’s breast cancer experience is of interest because of its shared genetics but vastly different diet compared with other parts of Asia. Methods Age-standardized breast cancer incidence and mortality rates obtained from the International Association of Cancer Registries are presented for several Asian countries. Mongolian incidence rates obtained from its cancer registry describe incidence within the country. Results Breast cancer incidence in Mongolia (age standardized 8.0/100,000) is almost a third of rates in China (21.6/100,000), and over five times that of Japan (42.7/100,000) and Russia (43.2/100,000). Rates within Mongolia appear to have increased slightly over the last decade and are higher in urban than rural areas (annual percentage increase of age-standardized rates from 1998 to 2005 was 3.60 and 2.57%, respectively). The increase in breast cancer incidence with age plateaus at menopause, as in other Asian populations. Conclusions Mongolia’s low breast cancer incidence is of particular interest because of their unusual diet (primarily red meat and dairy) compared with other Asian countries. More intensive study of potential dietary, reproductive and lifestyle factors in Mongolia with comparison to other Asian populations may provide more clarity in what drives the international breast cancer rate differences. PMID:22543542

  2. Optical measurement of microroughness of pigment coatings on rough substrates

    Science.gov (United States)

    Elton, N. J.

    2009-02-01

    The optical determination of rms roughness at the sub-wavelength scale by measurement of specular intensity as a function of wavelength or angle of incidence is well known. The method is normally used for specimens that are macroscopically flat. However, important industrial materials such as coated paper and paint consist of microscopically rough pigment coatings on a macroscopically rough substrate. Numerical modelling is used to assess the applicability and limitations of optical measurement of microroughness for such materials. Experimental results are presented for a range of paints on substrates of various macroroughness. Model and data are in fair agreement and show that the presence of substrate macroroughness always leads to an underestimation of microroughness. Generally, optical measurements of microroughness are only comparable for substrates of similar macroroughness and a limiting value exists above which measurements may not be meaningful.

  3. Optical measurement of microroughness of pigment coatings on rough substrates

    International Nuclear Information System (INIS)

    Elton, N J

    2009-01-01

    The optical determination of rms roughness at the sub-wavelength scale by measurement of specular intensity as a function of wavelength or angle of incidence is well known. The method is normally used for specimens that are macroscopically flat. However, important industrial materials such as coated paper and paint consist of microscopically rough pigment coatings on a macroscopically rough substrate. Numerical modelling is used to assess the applicability and limitations of optical measurement of microroughness for such materials. Experimental results are presented for a range of paints on substrates of various macroroughness. Model and data are in fair agreement and show that the presence of substrate macroroughness always leads to an underestimation of microroughness. Generally, optical measurements of microroughness are only comparable for substrates of similar macroroughness and a limiting value exists above which measurements may not be meaningful

  4. Optical twisters

    DEFF Research Database (Denmark)

    Daria, Vincent R.; Palima, Darwin; Glückstad, Jesper

    2010-01-01

    We describe a diffracting beam with orbital angular momentum (OAM) but with a helical profile in both phase and amplitude components of the beam. This is different from Laguerre-Gaussian (LG) beams where only the phase component has a helical profile. Such profile in LG beams introduces a phase s....... Such beams can be applied to fundamental studies of light and atoms such as in quantum entanglement of the OAM, toroidal traps for cold atoms and for optical manipulation of microscopic particles....... and linearly scaled towards no phase singularity at the centre of the beam. At the focal volume, we show that our beam forms an intensity distribution that can be accurately described as an "optical twister" as it propagates in the forward direction. Unlike LG beams, an optical twister can have minimal changes...... in radius but with a scalable OAM. Furthermore, we characterize the OAM in terms of its capacity to introduce spiral motion on particles trapped along its orbit. We also show that our "optical twister" maintains a high concentration of photons at the focus even as the topological charge is increased...

  5. Optical electromagnetic radiation detector

    International Nuclear Information System (INIS)

    Miceli, W. J.; Ludman, J. E.

    1985-01-01

    An optical electromagnetic radiation detector having a probe for receiving nearby electromagnetic radiation. The probe includes a loop antenna connected to a pair of transparent electrodes deposited on the end surfaces of an electro-optic Fabry-Perot interferometer. When the loop antenna picks up the presence of electromagnetic radiation, a voltage will be developed across the crystal of the electro-optic Fabry-Perot interferometer thereby changing the optical length of the interferometer. A beam of light from a remote location is transmitted through an optical fiber onto the Fabry-Perot interferometer. The change in optical length of the Fabry-Perot interferometer alters the intensity of the beam of light as it is reflected from the Fabry-Perot interferometer back through the optical fiber to the remote location. A beamsplitter directs this reflected beam of light onto an intensity detector in order to provide an output indicative of the variations in intensity. The variations in intensity are directly related to the strength of the electromagnetic radiation received by the loop antenna

  6. MCFRS Incidents by Station

    Data.gov (United States)

    Montgomery County of Maryland — This dataset contains the monthly summary data indicating incident occurred in each fire station response area. The summary data is the incident count broken down by...

  7. Police Incident Reports Written

    Data.gov (United States)

    Town of Chapel Hill, North Carolina — This table contains incident reports filed with the Chapel Hill Police Department. Multiple incidents may have been reported at the same time. The most serious...

  8. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  9. Linear and nonlinear intersubband optical absorption in a disk-shaped quantum dot with a parabolic potential plus an inverse squared potential in a static magnetic field

    International Nuclear Information System (INIS)

    Liu Guanghui; Guo Kangxian; Wang Chao

    2012-01-01

    The linear and nonlinear optical absorption in a disk-shaped quantum dot (DSQD) with parabolic potential plus an inverse squared potential in the presence of a static magnetic field are theoretically investigated within the framework of the compact-density-matrix approach and iterative method. The energy levels and the wave functions of an electron in the DSQD are obtained by using the effective mass approximation. Numerical calculations are presented for typical GaAs/AlAs DSQD. It is found that the optical absorption coefficients are strongly affected not only by a static magnetic field, but also by the strength of external field, the confinement frequency and the incident optical intensity.

  10. Incident Information Management Tool

    CERN Document Server

    Pejovic, Vladimir

    2015-01-01

    Flaws of\tcurrent incident information management at CMS and CERN\tare discussed. A new data\tmodel for future incident database is\tproposed and briefly described. Recently developed draft version of GIS-­‐based tool for incident tracking is presented.

  11. Grazing incidence diffraction : A review

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, B. [LTPCM, ENSEEG. St. Martin d`Heres. (France)

    1996-09-01

    Different Grazing Incidence Diffraction (GID) methods for the analysis of thin films and multilayer structures are reviewed in three sections: the reflectivity is developed in the first one, which includes the non-specular diffuse scattering. The second one is devoted to the extremely asymmetric Bragg diffraction and the third one to the in-plane Bragg diffraction. Analytical formulations of the scattered intensities are developed for each geometry, in the framework of the kinetical analysis as well as the dynamical theory. Experimental examples are given to illustrate the quantitative possibility of the GID techniques.

  12. A theoretical study on the optical properties of black silicon

    Science.gov (United States)

    Ma, Shijun; Liu, Shuang; Xu, Qinwei; Xu, Junwen; Lu, Rongguo; Liu, Yong; Zhong, Zhiyong

    2018-03-01

    There is a wide application prospect in black silicon, especially in solar cells and photoelectric detectors. For further optimization of black silicon, it is important to study its optical properties. Especially, the influence of the surface nanostructures on these properties and the light propagation within the nanostructures are relevant. In this paper, two kinds of black silicon models are studied via the finite differences time domain method. The simulated reflectance spectra matches well with the measured curve. Also, the light intensity distribution within the nanostructures shows that near 80% of the incident light are redirected and subjected to internal reflection, which provides powerful support for the good light trapping properties of black silicon.

  13. Non-conservative optical forces

    Science.gov (United States)

    Sukhov, Sergey; Dogariu, Aristide

    2017-11-01

    Undoubtedly, laser tweezers are the most recognized application of optically induced mechanical action. Their operation is usually described in terms of conservative forces originating from intensity gradients. However, the fundamental optical action on matter is non-conservative. We will review different manifestations of non-conservative optical forces (NCF) and discuss their dependence on the specific spatial properties of optical fields that generate them. New developments relevant to the NCF such as tractor beams and transversal forces are also discussed.

  14. Progress report on research project 'Coupled-channels optical model potentials for calculations with coupling built on soft-rotator model for nucleon induced reactions up to 200 MeV incident energies in A =24-120 mass region'

    International Nuclear Information System (INIS)

    Soukhovitski, E.

    2006-01-01

    Full text: During these nine months the Research Contract activity was developing according to the schedule as fixed in the Contract. Developing a global optical potential for even-even nuclides with A = 24-120 mass for coupled-channels optical model calculations based on coupling built on soft-rotator nuclear model Hamiltonian wave functions we already: 1. Determined Nuclear Hamiltonian parameters describing low-lying collective levels of even-even nuclides with A = 24-120 mass for all nuclides having experimental optical data available. 2. Formatted all the available optical experimental data for even-even nuclides with A = 24-120 mass into input of OPTMAN code for optical potential search option. Data still unavailable in the EXFOR database was submitted to the Nuclear Data Section for inclusion. 3. Derived a local OMP parameters for even-even A = 24-120 mass nuclides. 4. Release the OPTMAN code's user guide with the support of our Japanese collaborators. The User guide was published as JAERI technical report as cited below: E.Sh. Soukhovitskii, S. Chiba, O. Iwamoto, K. Shibata, T. Fukahori, G.B. Morogovskij (JAERI technical report 'Programs OPTMAN and SHEMMAN Version 8 (2004)', JAERI/Data-Code 2005-002, 2005). It is freely available on request from Japanese Nuclear Data Center. Global optical potential for even-even nuclides with A=24-120 mass, which is the main goal of the Contract's first year activity, will be derived based on individual optical potential parameters already determined. This research contract made possible very fruitful international scientific cooperation aimed to incorporate ideas on dispersive relationships between imaginary and real parts of optical potential developed earlier by Roberto Capote (IAEA/NDS) and Jose Manuel Quesada (Seville University) in the CC optical code OPTMAN. The real possibility to use a modified OPTMAN code for high priority practical applications arises. These activities are coordinated through RIPL CRP. We

  15. Review: Childhood and Adolescent Sexual Abuse: Incidence ...

    African Journals Online (AJOL)

    Other complications relate to sexually transmitted diseases, unwanted pregnancy and psychological pathologies such as intense anxiety, anger, depression, mood swings, nightmares, phobias and somatisation. This review discusses the apparent low incidence and of sexual abuse in children and adolescents, ...

  16. Development of a Standardized Method for Contouring the Lumbosacral Plexus: A Preliminary Dosimetric Analysis of this Organ at Risk Among 15 Patients Treated With Intensity-Modulated Radiotherapy for Lower Gastrointestinal Cancers and the Incidence of Radiation-Induced Lumbosacral Plexopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Sun K., E-mail: sun.yi@ucdmc.ucdavis.edu [Department of Radiation Oncology, University of California, Davis Cancer Center, Sacramento, CA (United States); Mak, Walter [Department of Radiology, University of California, Davis Medical Center, Sacramento, CA (United States); Yang, Claus C.; Liu Tianxiao [Department of Radiation Oncology, University of Mississippi Medical Center, Jackson, MS (United States); Cui Jing; Chen, Allen M.; Purdy, James A.; Monjazeb, Arta M. [Department of Radiation Oncology, University of California, Davis Cancer Center, Sacramento, CA (United States); Do, Ly [Cancer Care Institute, San Jose, CA (United States)

    2012-10-01

    Purpose: To generate a reproducible step-wise guideline for the delineation of the lumbosacral plexus (LSP) on axial computed tomography (CT) planning images and to provide a preliminary dosimetric analysis on 15 representative patients with rectal or anal cancers treated with an intensity-modulated radiotherapy (IMRT) technique. Methods and Materials: A standardized method for contouring the LSP on axial CT images was devised. The LSP was referenced to identifiable anatomic structures from the L4-5 interspace to the level of the sciatic nerve. It was then contoured retrospectively on 15 patients treated with IMRT for rectal or anal cancer. No dose limitations were placed on this organ at risk during initial treatment planning. Dosimetric parameters were evaluated. The incidence of radiation-induced lumbosacral plexopathy (RILSP) was calculated. Results: Total prescribed dose to 95% of the planned target volume ranged from 50.4 to 59.4 Gy (median 54 Gy). The mean ({+-}standard deviation [SD]) LSP volume for the 15 patients was 100 {+-} 22 cm{sup 3} (range, 71-138 cm{sup 3}). The mean maximal dose to the LSP was 52.6 {+-} 3.9 Gy (range, 44.5-58.6 Gy). The mean irradiated volumes of the LSP were V40Gy = 58% {+-} 19%, V50Gy = 22% {+-} 23%, and V55Gy = 0.5% {+-} 0.9%. One patient (7%) was found to have developed RILSP at 13 months after treatment. Conclusions: The true incidence of RILSP in the literature is likely underreported and is not a toxicity commonly assessed by radiation oncologists. In our analysis the LSP commonly received doses approaching the prescribed target dose, and 1 patient developed RILSP. Identification of the LSP during IMRT planning may reduce RILSP. We have provided a reproducible method for delineation of the LSP on CT images and a preliminary dosimetric analysis for potential future dose constraints.

  17. Incidence and risk factors for thrombocytopenia in the intensive care ...

    African Journals Online (AJOL)

    Table 1) and if there was recovery in platelet count after discontinuation of unfractionated heparin or low-molecular-weight heparin. Major bleeding was defined as any intracranial bleed or any bleed associated with a fall in haemoglobin by at least ...

  18. Intense, ultrashort light and dense, hot matter

    Indian Academy of Sciences (India)

    This article presents an overview of the physics and applications of the interaction of high intensity laser light with matter. It traces the crucial advances that have occurred over the past few decades in laser technology and nonlinear optics and then discusses physical phenomena that occur in intense laser fields and their ...

  19. Fiber optic hydrophone

    Science.gov (United States)

    Kuzmenko, P.J.; Davis, D.T.

    1994-05-10

    A miniature fiber optic hydrophone based on the principles of a Fabry-Perot interferometer is disclosed. The hydrophone, in one embodiment, includes a body having a shaped flexible bladder at one end which defines a volume containing air or suitable gas, and including a membrane disposed adjacent a vent. An optical fiber extends into the body with one end terminating in spaced relation to the membrane. Acoustic waves in the water that impinge on the bladder cause the pressure of the volume therein to vary causing the membrane to deflect and modulate the reflectivity of the Fabry-Perot cavity formed by the membrane surface and the cleaved end of the optical fiber disposed adjacent to the membrane. When the light is transmitted down the optical fiber, the reflected signal is amplitude modulated by the incident acoustic wave. Another embodiment utilizes a fluid filled volume within which the fiber optic extends. 2 figures.

  20. Fiber optic hydrophone

    Science.gov (United States)

    Kuzmenko, Paul J.; Davis, Donald T.

    1994-01-01

    A miniature fiber optic hydrophone based on the principles of a Fabry-Perot interferometer. The hydrophone, in one embodiment, includes a body having a shaped flexible bladder at one end which defines a volume containing air or suitable gas, and including a membrane disposed adjacent a vent. An optic fiber extends into the body with one end terminating in spaced relation to the membrane. Acoustic waves in the water that impinge on the bladder cause the pressure of the volume therein to vary causing the membrane to deflect and modulate the reflectivity of the Fabry-Perot cavity formed by the membrane surface and the cleaved end of the optical fiber disposed adjacent to the membrane. When the light is transmitted down the optical fiber, the reflected signal is amplitude modulated by the incident acoustic wave. Another embodiment utilizes a fluid filled volume within which the fiber optic extends.

  1. Optical transmissivity of metallic nanowires

    Science.gov (United States)

    Nairat, Mazen S.

    2017-08-01

    Optical transmissivity and reflectivity of one dimensional array of metallic nanowires embedded in transparent dielectric is characterized. i employ wave optics simulation to analyze the optical field distribution in both the dielectric and the nanowires. The results indicate that the transmissivity and reflectivity depend on the polarization states of the incident light. The metallic nanowires matrix transmit in-plane polarization but block light out at of-plane polarization.

  2. Advances in thin film diffraction instrumentation by X-ray optics

    International Nuclear Information System (INIS)

    Haase, A.

    1996-01-01

    The structural characterisation of thin films requires a parallel X-ray beam of high intensity. Parallel beam geometry is commonly used in high resolution and single crystal experiments, but also in the field of X-ray diffraction for polycrystalline material (e.g. in phase, texture and stress analysis). For grazing incidence diffraction (GID), the use of small slits on the primary side and of long soller slits with a flat monochromator on the secondary side is standard. New optical elements have been introduced with polychromatic or monochromatic radiation. By means of different applications the results are compared with those of classical beam optics. X-ray fiber optics utilize total external reflection of X-rays on smooth surfaces. Effects of monochromatization are presented. In many fields of application, fiber optics may replace conventional collimators. The use of primary and secondary channel cut crystals can also produce a high parallel monochromatic X-ray beam. A parabolically bent graded multilayer produces a monochromatic parallel beam of high intensity. Compared with classical Bragg-Brentano (focussing) geometry, excellent results have been obtained, especially for samples with an irregular shape. In combination with a channel cut monochromator there is a substantial gain in intensity leading to an increase of the dynamic intensity range of rocking curves

  3. Advances in thin film diffraction instrumentation by X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Haase, A. [Rich. Seifert and Co., Analytical X-ray Systems, Ahrensburg (Germany)

    1996-09-01

    The structural characterisation of thin films requires a parallel X-ray beam of high intensity. Parallel beam geometry is commonly used in high resolution and single crystal experiments, but also in the field of X-ray diffraction for polycrystalline material (e.g. in phase, texture and stress analysis). For grazing incidence diffraction (GID), the use of small slits on the primary side and of long soller slits with a flat monochromator on the secondary side is standard. New optical elements have been introduced with polychromatic or monochromatic radiation. By means of different applications the results are compared with those of classical beam optics. X-ray fiber optics utilize total external reflection of X-rays on smooth surfaces. Effects of monochromatization are presented. In many fields of application, fiber optics may replace conventional collimators. The use of primary and secondary channel cut crystals can also produce a high parallel monochromatic X-ray beam. A parabolically bent graded multilayer produces a monochromatic parallel beam of high intensity. Compared with classical Bragg-Brentano (focussing) geometry, excellent results have been obtained, especially for samples with an irregular shape. In combination with a channel cut monochromator there is a substantial gain in intensity leading to an increase of the dynamic intensity range of rocking curves.

  4. Investigation of optical spacer layers from solution based precursors for polymer solar cells using X-ray reflectometry

    DEFF Research Database (Denmark)

    Andersen, Philip Hvidthøft Delff; Skårhøj, Jakob; Andreasen, Jens Wenzel

    2009-01-01

    Optical spacer layers based on titaniumalkoxide precursor solutions were prepared by spin-coating on top of bulk heterojunction layers based on poly-3-hexylthiophene (P3HT) and phenyl-C61-butyric acid methylester (PCBM). Models and experiment have shown that the performance of polymer solar cells...... can improve upon application of an optical spacer by shifting the maximum of the electrical field vector of the incident light into the active layer. This avoids the so called “dead zone” close to the reflective electrode. We demonstrate a simple linear model that can be used to predict the intensity...

  5. Plasmon-enhanced optically stimulated luminescence

    International Nuclear Information System (INIS)

    Guidelli, E. J.; Baffa, O.; Ramos, A. P.

    2015-10-01

    Full text: Optically Stimulated Luminescence dosimeters (OSLD) have been largely used for personal, medical, and industrial radiation dosimetry. Developing highly sensitive and small-sized radiation detectors and dosimeters is essential for improving spatial resolution and consequently diagnosis quality and treatment efficacy in the case of applications in radiodiagnosis and radiation therapy, for instance. Conventional methods to improve the OSLD sensitivity consist of doping and co-doping the host materials with atoms of other elements, thereby increasing the amount of trapping and/or luminescent centers. Our group is researching on the use of the plasmon properties of noble metal nanoparticles to increase OSL intensity. Upon incidence of a light beam with appropriate resonant wavelengths, the oscillation of the free electrons at the nanoparticle surface originates the Localized Surface Plasmons (LSP) and the consequent plasmon resonance band. The interaction between the LSP and the surrounding luminescent material leads to new optical properties largely employed for enhancing several luminescent processes. Here we will show our results regarding the use of LSP to increase OSLD sensitivity. The interaction between the traps/luminescent centers and the plasmons depends on the distance between them, on the plasmon resonance band intensity and position, as well as on the surrounding medium. Therefore, the plasmon-enhanced luminescence is a promising tool to develop more sensitive and miniaturized OSLD. (Author)

  6. Plasmon-enhanced optically stimulated luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Guidelli, E. J.; Baffa, O. [Universidade de Sao Paulo, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Departamento de Fisica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Ramos, A. P., E-mail: ederguidelli@gmail.com [Universidade de Sao Paulo, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Departamento de Quimica, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, Sao Paulo (Brazil)

    2015-10-15

    Full text: Optically Stimulated Luminescence dosimeters (OSLD) have been largely used for personal, medical, and industrial radiation dosimetry. Developing highly sensitive and small-sized radiation detectors and dosimeters is essential for improving spatial resolution and consequently diagnosis quality and treatment efficacy in the case of applications in radiodiagnosis and radiation therapy, for instance. Conventional methods to improve the OSLD sensitivity consist of doping and co-doping the host materials with atoms of other elements, thereby increasing the amount of trapping and/or luminescent centers. Our group is researching on the use of the plasmon properties of noble metal nanoparticles to increase OSL intensity. Upon incidence of a light beam with appropriate resonant wavelengths, the oscillation of the free electrons at the nanoparticle surface originates the Localized Surface Plasmons (LSP) and the consequent plasmon resonance band. The interaction between the LSP and the surrounding luminescent material leads to new optical properties largely employed for enhancing several luminescent processes. Here we will show our results regarding the use of LSP to increase OSLD sensitivity. The interaction between the traps/luminescent centers and the plasmons depends on the distance between them, on the plasmon resonance band intensity and position, as well as on the surrounding medium. Therefore, the plasmon-enhanced luminescence is a promising tool to develop more sensitive and miniaturized OSLD. (Author)

  7. Incident laser modulation of a repaired damage site with a rim in fused silica rear subsurface

    International Nuclear Information System (INIS)

    Li Li; Xiang Xia; Zu Xiao-Tao; Yuan Xiao-Dong; He Shao-Bo; Jiang Xiao-Dong; Zheng Wan-Guo

    2012-01-01

    Local CO 2 laser treatment has proved to be an effective method to prevent the 351-nm laser-induced damage sites in a fused silica surface from exponentially growing, which is responsible for limiting the lifetime of optics in high fluence laser systems. However, the CO 2 laser induced ablation crater is often surrounded by a raised rim at the edge, which can also result in the intensification of transmitted ultraviolet light that may damage the downstream optics. In this work, the three-dimensional finite-difference time-domain method is developed to simulate the distribution of electrical field intensity in the vicinity of the CO 2 laser mitigated damage site located in the exit subsurface of fused silica. The simulated results show that the repaired damage sites with raised rims cause more notable modulation to the incident laser than those without rims. Specifically, we present a theoretical model of using dimpled patterning to control the rim structure around the edge of repaired damage sites to avoid damage to downstream optics. The calculated results accord well with previous experimental results and the underlying physical mechanism is analysed in detail. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  8. Theoretical and Experimental Optical Evaluation and Comparison of Symmetric 2D CPC and V-Trough Collector for Photovoltaic Applications

    Directory of Open Access Journals (Sweden)

    Damasen Ikwaba Paul

    2015-01-01

    Full Text Available This paper presents theoretical and experimental optical evaluation and comparison of symmetric Compound Parabolic Concentrator (CPC and V-trough collector. For direct optical properties comparison, both concentrators were deliberately designed to have the same geometrical concentration ratio (1.96, aperture area, absorber area, and maximum concentrator length. The theoretical optical evaluation of the CPC and V-trough collector was carried out using a ray-trace technique while the experimental optical efficiency and solar energy flux distributions were analysed using an isolated cell PV module method. Results by simulation analysis showed that for the CPC, the highest optical efficiency was 95% achieved in the interval range of 0° to ±20° whereas the highest outdoor experimental optical efficiency was 94% in the interval range of 0° to ±20°. For the V-tough collector, the highest optical efficiency for simulation and outdoor experiments was about 96% and 93%, respectively, both in the interval range of 0° to ±5°. Simulation results also showed that the CPC and V-trough exhibit higher variation in non-illumination intensity distributions over the PV module surface for larger incidence angles than lower incidence angles. On the other hand, the maximum power output for the cells with concentrators varied depending on the location of the cell in the PV module.

  9. Acute incidents during anaesthesia

    African Journals Online (AJOL)

    Incidents can occur during induction, maintenance and emergence from anaesthesia. The following acute critical incidents are discussed in this article: • Anaphylaxis. • Aspiration ..... Already used in South Africa and Malawi, a scale-up of the technique is under way in Tanzania, Rwanda and Ghana. The report found that.

  10. Microchip Flow Cytometer with Integrated Polymer Optical Elements for Measurement of Scattered Light

    DEFF Research Database (Denmark)

    Wang, Zhenyu; El-Ali, Jamil; Perch-Nielsen, Ivan Ryberg

    2004-01-01

    Flow cytometry is a very powerful method for biophysical measurement of microparticles, such as cells and bacteria. In this paper, we report an innovative microsystem, in which several different optical elements (waveguides, lenses and fiber-to-waveguide couplers) are integrated with microfluidic...... processes can be finished in one day. Polystyrene beads were measured in the microchip flow cytometer, and three signals (forward scattering, large angle scattering and extinction) were measured simultaneously for each bead. The average intensities of the forward Scattered light and the incident light...... extinction showed excellent linear relationship with the sizes of the beads. To our knowledge this is the first time forward scattered light and incident light extinction were measured in a microsystem using integrated optics. The microsystem can be applied for analyzing different kinds of particles...

  11. Flexoelectro-optic properties of chiral nematic liquid crystals in the uniform standing helix configuration

    Science.gov (United States)

    Castles, F.; Morris, S. M.; Coles, H. J.

    2009-09-01

    The flexoelectro-optic effect describes the rotation of the optic axis of a short-pitch chiral nematic liquid crystal under the application of an electric field. We investigate the effect in the uniform standing helix, or “Grandjean” configuration. An in-plane electric field is applied. The director profile is determined numerically using a static one-dimensional continuum model with strong surface anchoring. The Berreman method is used to solve for plane-wave solutions to Maxwell’s equations, and predict the optical properties of the resulting structure in general cases. By using a chiral nematic with short pitch between crossed polarizers an optical switch may be generated. With no applied field the configuration is nontransmissive at normal incidence, but becomes transmissive with an applied field. For this case, numerical results using the Berreman method are supplemented with an analytic theory and found to be in good agreement. The transmitted intensity as a function of tilt, the contrast ratio, and the tilt required for full intensity modulation are presented. The angular dependence of the transmission is calculated and the isocontrast curves are plotted. For typical material and cell parameters a switching speed of 0.017 ms and contrast ratio of 1500:1 at normal incidence are predicted, at a switch-on tilt of 41.5 degrees. Experimental verification of the analytic and numerical models is provided.

  12. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  13. UltraForm Finisher Optical Mandrel Fabrication, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The requirements for cost effective manufacturing and metrology of normal incidence and grazing incidence X-Ray optical surfaces is instrumental for the success of...

  14. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... activity: relative intensity and absolute intensity. Relative Intensity The level of effort required by a person to do an activity. When using relative intensity, people pay attention to how physical activity affects their heart rate ...

  15. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, 4: ... ways to understand and measure the intensity of aerobic activity: relative intensity and absolute intensity. Relative Intensity ...

  16. Measurement of the absorption coefficient of acoustical materials using the sound intensity method

    Science.gov (United States)

    Atwal, Mahabir S.; Crocker, Malcolm J.

    1987-01-01

    In this study the possibility of using the two-microphone sound intensity technique to measure the normal incidence and the random incidence sound absorption coefficient was investigated. The normal incidence absorption coefficient was determined by measuring the intensity incidence on the sample and the intensity reflected by the sample placed in an anechoic chamber. The random incidence absorption coefficient was determined by measuring the intensity incident on the sample and the intensity reflected by the sample placed in a reverberation chamber. Absorption coefficient results obtained by the sound intensity technique were compared with standard techniques, namely the reverberation chamber and the standing wave tube. The major advantages of using the sound intensity technique are that it permits 'in situ' measurements and the absorption coefficient for a large range of frequencies can be obtained from a single measurement.

  17. Calibration of rock-surface moisture content using an infrared optical moisture metre : the relationship between absorbance intensity and moisture content of several types of rock

    OpenAIRE

    Matsukura, Yukinori

    2001-01-01

    Matsukura and Takahashi(1999)have examined the possibility of in situ rapid, non-destrucive measuring of rock moisture content using an infrared optical moisture metre. A laboratory test was carried out using ...

  18. Raman spectroscopy an intensity approach

    CERN Document Server

    Guozhen, Wu

    2017-01-01

    This book summarizes the highlights of our work on the bond polarizability approach to the intensity analysis. The topics covered include surface enhanced Raman scattering, Raman excited virtual states and Raman optical activity (ROA). The first chapter briefly introduces the Raman effect in a succinct but clear way. Chapter 2 deals with the normal mode analysis. This is a basic tool for our work. Chapter 3 introduces our proposed algorithm for the Raman intensity analysis. Chapter 4 heavily introduces the physical picture of Raman virtual states. Chapter 5 offers details so that the readers can have a comprehensive idea of Raman virtual states. Chapter 6 demonstrates how this bond polarizability algorithm is extended to ROA intensity analysis. Chapters 7 and 8 offer details on ROA, showing many findings on ROA mechanism that were not known or neglected before. Chapter 9 introduces our proposed classical treatment on ROA which, as combined with the results from the bond polarizability analysis, leads to a com...

  19. Critical incident stress management.

    Science.gov (United States)

    Lim, J J; Childs, J; Gonsalves, K

    2000-10-01

    Recent studies have indicated implementation of the CISM Program has impacted and reduced the cost of workers' compensation claims for stress related conditions and the number of lost work days (Ott, 1997; Western Management Consultants, 1996). Occupational health professionals need to be ready to develop and implement a comprehensive critical incident stress management process in anticipation of a major event. The ability to organize, lead, or administer critical incident stress debriefings for affected employees is a key role for the occupational health professional. Familiarity with these concepts and the ability to identify a critical incident enhances value to the business by mitigating the stress and impact to the workplace. Critical Incident Stress Management Systems have the potential for decreasing stress and restoring employees to normal life function--a win/win situation for both the employees and the organization.

  20. Marine Animal Incident Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Large whale stranding, death, ship strike and entanglement incidents are all recorded to monitor the health of each population and track anthropogenic factors that...

  1. Police Incident Blotter (Archive)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Police Blotter Archive contains crime incident data after it has been validated and processed to meet Uniform Crime Reporting (UCR) standards, published on a...

  2. Prediction of Safety Incidents

    Data.gov (United States)

    National Aeronautics and Space Administration — Safety incidents, including injuries, property damage and mission failures, cost NASA and contractors thousands of dollars in direct and indirect costs. This project...

  3. 2011 Japanese Nuclear Incident

    Science.gov (United States)

    EPA’s RadNet system monitored the environmental radiation levels in the United States and parts of the Pacific following the Japanese Nuclear Incident. Learn about EPA’s response and view historical laboratory data and news releases.

  4. Information Security Incident Management

    Directory of Open Access Journals (Sweden)

    D. I. Persanov

    2010-03-01

    Full Text Available The present report highlights the points of information security incident management in an enterprise. Some aspects of the incident and event classification are given. The author presents his view of the process scheme over the monitoring and processing information security events. Also, the report determines a few critical points of the listed process and gives the practical recommendations over its development and optimization.

  5. Fundamentals of nonlinear optical materials

    Indian Academy of Sciences (India)

    Optical solitons, optical switching and memory by NLO effects, which depend on light intensity, are expected to result in the realization of pivotal .... The term squeezing refers to the generation of special states of electromagnetic fields in which noises are reduced to that below the quantum noise level. This is in accor-.

  6. Figure and finish of grazing incidence mirrors

    International Nuclear Information System (INIS)

    Takacs, P.Z.; Church, E.L.

    1989-08-01

    Great improvement has been made in the past several years in the quality of optical components used in synchrotron radiation (SR) beamlines. Most of this progress has been the result of vastly improved metrology techniques and instrumentation permitting rapid and accurate measurement of the surface finish and figure on grazing incidence optics. A significant theoretical effort has linked the actual performance of components used as x-ray wavelengths to their topological properties as measured by surface profiling instruments. Next-generation advanced light sources will require optical components and systems to have sub-arc second surface figure tolerances. This paper will explore the consequences of these requirements in terms of manufacturing tolerances to see if the present manufacturing state-of-the-art is capable of producing the required surfaces. 15 refs., 14 figs., 2 tabs

  7. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2000-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  8. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2005-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  9. Dynamic array of dark optical traps

    DEFF Research Database (Denmark)

    Daria, V.R.; Rodrigo, P.J.; Glückstad, J.

    2004-01-01

    A dynamic array of dark optical traps is generated for simultaneous trapping and arbitrary manipulation of multiple low-index microstructures. The dynamic intensity patterns forming the dark optical trap arrays are generated using a nearly loss-less phase-to-intensity conversion of a phase-encode...

  10. Fourth Order Nonlinear Intensity and the corresponding Refractive ...

    African Journals Online (AJOL)

    Nonlinear effects occur whenever the optical fields associated with one or more intense light such as from laser beams propagating in a crystal are large enough to produce polarization fields. This paper describes how the fourth order nonlinear intensity and the corresponding effective refractive index that is intensity ...

  11. Solid state optical microscope

    Science.gov (United States)

    Young, Ian T.

    1983-01-01

    A solid state optical microscope wherein wide-field and high-resolution images of an object are produced at a rapid rate by utilizing conventional optics with a charge-coupled photodiode array. A galvanometer scanning mirror, for scanning in one of two orthogonal directions is provided, while the charge-coupled photodiode array scans in the other orthogonal direction. Illumination light from the object is incident upon the photodiodes, creating packets of electrons (signals) which are representative of the illuminated object. The signals are then processed, stored in a memory, and finally displayed as a video signal.

  12. Microstructured Optical Fibres

    DEFF Research Database (Denmark)

    1999-01-01

    complete PBGs, which reflects light incident from air or vacuum. Such structures may be used as cladding structures in optical fibres, where light is confined and thereby guided in a hollow core region. In addition, the present invention relates to designs for ultra low-loss PBG waveguiding structures......The present invention relates to a new class of optical waveguides, in which waveguiding along one or more core regions is obtained through the application of the Photonic Bandgap (PBG) effect. The invention further relates to optimised two-dimensional lattice structures capable of providing...

  13. Quantum optics

    National Research Council Canada - National Science Library

    Agarwal, G. S

    2013-01-01

    .... Focusing on applications of quantum optics, the textbook covers recent developments such as engineering of quantum states, quantum optics on a chip, nano-mechanical mirrors, quantum entanglement...

  14. Optical Pattern Recognition With Self-Amplification

    Science.gov (United States)

    Liu, Hua-Kuang

    1994-01-01

    In optical pattern recognition system with self-amplification, no reference beam used in addressing mode. Polarization of laser beam and orientation of photorefractive crystal chosen to maximize photorefractive effect. Intensity of recognition signal is orders of magnitude greater than other optical correlators. Apparatus regarded as real-time or quasi-real-time optical pattern recognizer with memory and reprogrammability.

  15. Radiation incidents in dentistry

    International Nuclear Information System (INIS)

    Lovelock, D.J.

    1996-01-01

    Most dental practitioners act as their own radiographer and radiologist, unlike their medical colleagues. Virtually all dental surgeons have a dental X-ray machine for intraoral radiography available to them and 40% of dental practices have equipment for dental panoramic tomography. Because of the low energy of X-ray equipment used in dentistry, radiation incidents tend to be less serious than those associated with other aspects of patient care. Details of 47 known incidents are given. The advent of the 1985 and 1988 Ionising Radiation Regulations has made dental surgeons more aware of the hazards of radiation. These regulations, and general health and safety legislation, have led to a few dental surgeons facing legal action. Because of the publicity associated with these court cases, it is expected that there will be a decrease in radiation incidents arising from the practice of dentistry. (author)

  16. Intensive Care Unit Delirium

    Directory of Open Access Journals (Sweden)

    Yongsuk Kim

    2015-05-01

    Full Text Available Delirium is described as a manifestation of acute brain injury and recognized as one of the most common complications in intensive care unit (ICU patients. Although the causes of delirium vary widely among patients, delirium increases the risk of longer ICU and hospital length of stay, death, cost of care, and post-ICU cognitive impairment. Prevention and early detection are therefore crucial. However, the clinical approach toward delirium is not sufficiently aggressive, despite the condition’s high incidence and prevalence in the ICU setting. While the underlying pathophysiology of delirium is not fully understood, many risk factors have been suggested. As a way to improve delirium-related clinical outcome, high-risk patients can be identified. A valid and reliable bedside screening tool is also needed to detect the symptoms of delirium early. Delirium is commonly treated with medications, and haloperidol and atypical antipsychotics are commonly used as standard treatment options for ICU patients although their efficacy and safety have not been established. The approaches for the treatment of delirium should focus on identifying the underlying causes and reducing modifiable risk factors to promote early mobilization.

  17. Reflection and transmission of normally incident full-vector X waves on planar interfaces

    KAUST Repository

    Salem, Mohamed

    2011-12-23

    The reflection and transmission of full-vector X waves normally incident on planar half-spaces and slabs are studied. For this purpose, X waves are expanded in terms of weighted vector Bessel beams; this new decomposition and reconstruction method offers a more lucid and intuitive interpretation of the physical phenomena observed upon the reflection or transmission of X waves when compared to the conventional plane-wave decomposition technique. Using the Bessel beam expansion approach, we have characterized changes in the field shape and the intensity distribution of the transmitted and reflected full-vector X waves. We have also identified a novel longitudinal shift, which is observed when a full-vector X wave is transmitted through a dielectric slab under frustrated total reflection condition. The results of our studies presented here are valuable in understanding the behavior of full-vector X waves when they are utilized in practical applications in electromagnetics, optics, and photonics, such as trap and tweezer setups, optical lithography, and immaterial probing. © 2011 Optical Society of America.

  18. Optical RF Spectrum Analyzer

    Science.gov (United States)

    trapping (ET) material of a spatial light modulator (SLM). A second optical subsystem directs coherent blue light generated by an argon laser to...resulting in the emissions of incoherent visible light. The incident coherent blue light is selectively absorbed at these exposed locations as it acts...filter. The coherent blue light which passes through the ET-SLM is Fourier transformed by a Fourier lens, and then detected by a CCD detector.

  19. Measurement of muon intensity by Cerenkov method

    Science.gov (United States)

    Liu, Z. H.; Li, G. J.; Bai, G. Z.; Liu, J. G.; Geng, Q. X.; Ling, J.

    1985-01-01

    Optical detection is an important technique in studies and observations of air showers, muons and relevant phenomena. The muon intensity is measured in a proper energy range and to study some problems about Cerenkov radiation of cosmic rays are studied, by a muon-telescope operated with Cerenkov detector. It is found that the measured muon intensity agrees with the integral energy spectrum of cosmic ray muons.

  20. Astronomical optics and elasticity theory

    CERN Document Server

    Lemaitre, Gerard Rene

    2008-01-01

    Astronomical Optics and Elasticity Theory provides a very thorough and comprehensive account of what is known in this field. After an extensive introduction to optics and elasticity, the book discusses variable curvature and multimode deformable mirrors, as well as, in depth, active optics, its theory and applications. Further, optical design utilizing the Schmidt concept and various types of Schmidt correctors, as well as the elasticity theory of thin plates and shells are elaborated upon. Several active optics methods are developed for obtaining aberration corrected diffraction gratings. Further, a weakly conical shell theory of elasticity is elaborated for the aspherization of grazing incidence telescope mirrors. The very didactic and fairly easy-to-read presentation of the topic will enable PhD students and young researchers to actively participate in challenging astronomical optics and instrumentation projects.

  1. Measurement of the absorption coefficient using the sound-intensity technique

    Science.gov (United States)

    Atwal, M.; Bernhard, R.

    1984-01-01

    The possibility of using the sound intensity technique to measure the absorption coefficient of a material is investigated. This technique measures the absorption coefficient by measuring the intensity incident on the sample and the net intensity reflected by the sample. Results obtained by this technique are compared with the standard techniques of measuring the change in the reverberation time and the standing wave ratio in a tube, thereby, calculating the random incident and the normal incident adsorption coefficient.

  2. Two mode optical fiber in space optics communication

    Science.gov (United States)

    Hampl, Martin

    2017-11-01

    In our contribution we propose to use of a two-mode optical fiber as a primary source in a transmitting optical head instead of the laser diode. The distribution of the optical intensity and the complex degree of the coherence on the output aperture of the lens that is irradiated by a step-index weakly guiding optical fiber is investigated. In our treatment we take into account weakly guided modes with polarization corrections to the propagation constant and unified theory of second order coherence and polarization of electromagnetic beams.

  3. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... videos Here are some ways to understand and measure the intensity of aerobic activity: relative intensity and ... The talk test is a simple way to measure relative intensity. In general, if you're doing ...

  4. Optical reflectance in fibrous tissues and skeletal muscles

    Science.gov (United States)

    Ranasinghesagara, Janaka C.

    We studied two biological tissues with optically anisotropic structures: high moisture soy protein extrudates and skeletal muscles. High moisture extrusion has been used to produce vegetable meat analogs that resemble real animal meat and have significant health benefits. Since visual and textural properties are key factors for consumer acceptance, assessing fiber formation in the extruded soy protein product is important for quality control purpose. A non-destructive method based on photon migration was developed to measure fiber formation in extruded soy proteins. The measured fiber formation index in intact samples showed good agreement with that obtained from image analysis on peeled samples. By implementing this new method in a fast laser scanning system, we have acquired two dimensional mappings of fiber formation and orientation in the entire sample in real time. In addition to fibrous structures, skeletal muscles have a unique periodic sarcomere structure which produces strong light diffractions. However, inconsistent experimental results have been reported in single fiber diffraction studies. By applying the three-dimensional coupled wave theory in a physical sarcomere model, we found that a variety of experimental observations can be explained if inhomogeneous muscle morphological profiles are considered. We also discovered that the sarcomere structure produced a unique optical reflectance pattern in whole muscle. None of the existing light propagation theories are able to describe this pattern. We developed a Monte Carlo model incorporating the sarcomere diffraction effect. The simulated results quantitatively resemble the unique patterns observed in experiments. We used a set of parameters to quantify the optical reflectance profiles produced by a point incident light in whole muscle. Two parameters, q and B, were obtained by numerically fitting the equi-intensity contours of the reflectance pattern. Two spatial gradients were calculated along the

  5. Optical Computing

    Indian Academy of Sciences (India)

    Optics has been used in computing for a number of years but the main emphasis has been and continues to be to link portions of computers, for communications, or more intrin- sically in devices that have some optical application or component (optical pattern recognition, etc). Optical digi- tal computers are still some years ...

  6. Incident spectrum determination for time-of-flight neutron powder diffraction data analysis

    International Nuclear Information System (INIS)

    Hodges, J. P.

    1998-01-01

    Accurate characterization of the incident neutron spectrum is an important requirement for precise Rietveld analysis of time-of-flight powder neutron diffraction data. Without an accurate incident spectrum the calculated model for the measured relative intensities of individual Bragg reflections will possess systematic errors. We describe a method for obtaining an accurate numerical incident spectrum using data from a transmitted beam monitor

  7. Incidents in nuclear installations

    International Nuclear Information System (INIS)

    Franzen, L.F.; Wienhold, W.

    1976-09-01

    With reference to the incident list of the Ministry for the period 1971-74, Prof. Bechert has expressed a lot of questions and statements in a letter to the Government. The letter is quoted in full. Inadequate conclusions drawn by Prof. Bechert in connection with quotations from daily newspapers and other documents are put right. (HP) [de

  8. Lightning incidents in Mongolia

    Directory of Open Access Journals (Sweden)

    Myagmar Doljinsuren

    2015-11-01

    Full Text Available This is one of the first studies that has been conducted in Mongolia on the distribution of lightning incidents. The study covers a 10-year period from 2004 to 2013. The country records a human death rate of 15.4 deaths per 10 million people per year, which is much higher than that of many countries with similar isokeraunic level. The reason may be the low-grown vegetation observed in most rural areas of Mongolia, a surface topography, typical to steppe climate. We suggest modifications to Gomes–Kadir equation for such countries, as it predicts a much lower annual death rate for Mongolia. The lightning incidents spread over the period from May to August with the peak of the number of incidents occurring in July. The worst lightning affected region in the country is the central part. Compared with impacts of other convective disasters such as squalls, thunderstorms and hail, lightning stands as the second highest in the number of incidents, human deaths and animal deaths. Economic losses due to lightning is only about 1% of the total losses due to the four extreme weather phenomena. However, unless precautionary measures are not promoted among the public, this figure of losses may significantly increase with time as the country is undergoing rapid industrialization at present.

  9. Fire Incident Reporting Manual

    Science.gov (United States)

    1984-02-01

    the result of an incident that requires (or should require) treatment by a practitioner of medicine , a registered emergency medical technician, or a...UNANNOUNCED AIRCRAFT EMERGENCYS ~~PRIOR TO TAKE OFF OR AFTERLADN 5 FUEL OPERATIONS REQUIRING 1AREING G A FIRE10 ARRESTING GEAR’BARRIER FR . ENGAGEMENTS AND

  10. Mie scattering eigenmodes for optical trapping

    OpenAIRE

    Mazilu, Michael

    2017-01-01

    The Mie scattering theory enables the exact determination of the scattered field as a function of the incident field. Here, we use this approach to calculate the Hermitian relationship between the incident field and the optical forces acting on the scattering objects. This Hermitian relationship defines also a set of orthogonal optical eigenmodes which deliver a natural basis to describe momentum transfer in light-matter interactions. Publisher PDF Non peer reviewed

  11. Carrier-envelope phase-dependent ionization of Xe in intense, ultrafast (two-cycle) laser fields

    Science.gov (United States)

    Vasa, Parinda; Dharmadhikari, Aditya K.; Mathur, Deepak

    2018-01-01

    We report an experimental study that shows the dependence of the tunnel ionization of Xe by two-cycle, intense, near infrared light on the carrier-envelope-phase (CEP) of incident laser pulses. At low values of the optical field (E), the ionization yield is found to be maximum for cos-like pulses; the CEP dependence of the ion yield becomes stronger for higher charge states. At higher E-values, the CEP dependence either washes out or flips. A simple phenomenological model is used to confirm that our results fall within the ambit of the current understanding of ionization dynamics in strong, ultrashort optical fields. In the observed tunnel ionization of Xe, CEP effects appear to persist for longer, eight-cycle, pulses. Electron rescattering is observed to play a relatively unimportant role in the observed CEP dependence. These results provide fresh perspectives in the ionization mechanisms of multielectron systems in the few-cycle regime.

  12. Compact, low-cost, and high-resolution interrogation unit for optical sensors

    International Nuclear Information System (INIS)

    Kiesel, Peter; Schmidt, Oliver; Mohta, Setu; Johnson, Noble; Malzer, Stefan

    2006-01-01

    Compact wavelength detectors that resolve wavelength changes in the subpicometer range over a broad spectral range are presented. A photodiode array or position sensor device is coated with a linear variable filter that converts the wavelength of the incident light into a spatial intensity distribution. The centroid of the spatial distribution is determined by a differential readout of the two elements of the photodiode array or the position sensor device. The device can interrogate any optical sensor that produces a wavelength shift in response to a stimulus. The potential of this device was tested by interrogating fiber-Bragg-grating sensors

  13. Optical correlation algorithm for reconstructing phase skeleton of complex optical fields for solving the phase problem

    DEFF Research Database (Denmark)

    Angelsky, O. V.; Gorsky, M. P.; Hanson, Steen Grüner

    2014-01-01

    We propose an optical correlation algorithm illustrating a new general method for reconstructing the phase skeleton of complex optical fields from the measured two-dimensional intensity distribution. The core of the algorithm consists in locating the saddle points of the intensity distribution an...

  14. A Tool for the Concise Analysis of Patient Safety Incidents.

    Science.gov (United States)

    Pham, Julius Cuong; Hoffman, Carolyn; Popescu, Ioana; Ijagbemi, O Mayowa; Carson, Kathryn A

    2016-01-01

    Patient safety incidents, sometimes referred to as adverse events, incidents, or patient safety events, are too common an occurrence in health care. Most methods for incident analysis are time and labor intensive. Given the significant resource requirements of a root cause analysis, for example, there is a need for a more targeted and efficient method of analyzing a larger number of incidents. Although several concise incident analysis tools are in existence, there are no published studies regarding their usability or effectiveness. Building on previous efforts, a Concise Incident Analysis (CIA) methodology and tool were developed to facilitate analysis of no- or low-harm incidents. Staff from 11 hospitals in five countries-Australia, Canada, Hong Kong, India, and the United States-pilot tested the tool in two phases. The tool was evaluated and refined after each phase on the basis of user perceptions of usability and effectiveness. From September 2013 through January 2014, 52 patient safety incidents were analyzed. A broad variety of incident types were investigated, the most frequent being patient falls (25%). Incidents came from a variety of hospital work areas, the most frequent being from the medical ward (37%). Most incidents investigated resulted in temporary harm or no harm (94%). All or most sites found the tool "understandable" (100%), "easy to use" (89%), and "effective" (89%). Some 95% of participants planned to continue to use all or some parts of the tool after the pilot. Qualitative feedback suggested that the tool allowed analysis of incidents that were not currently being analyzed because of insufficient resources. The tool was described as simple to use, easy to document, and aligned with the flow of the incident analysis. A concise tool for the investigation of patient safety incidents with low or no harm was well accepted across a select group of hospitals from five countries.

  15. Fluorescent optical position sensor

    Science.gov (United States)

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  16. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    Energy Technology Data Exchange (ETDEWEB)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C. [Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy); Gupta, A. [Department of Chemistry, University of Alabama, Tuscaloosa, Alabama 35487 (United States); Carpene, E., E-mail: ettore.carpene@polimi.it [CNR-IFN, Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO{sub 2} single crystals as a benchmark.

  17. Experimental examination of frequency locking effect in acousto-optic system

    Science.gov (United States)

    Mantsevich, S. N.; Balakshy, V. I.

    2018-04-01

    The optoelectronic system containing collinear acousto-optic cell fabricated on the base of calcium molybdate crystal and positive electronic feedback circuit was examined. The feedback signal is formed due to the optical heterodyning effect that occurs on the cell output and takes place in the special regime of collinear acousto-optic diffraction. It was discovered that three operation modes that may exist in this system. The boundaries between the modes were determined. The positions of the boundaries depend on the main parameters of the system—the incident light intensity and the feedback gain value. The new for acousto-optics phenomenon of acousto-optic system self-oscillations frequency locking by the RF generator signal was discovered and examined experimentally. Such an effect has never been observed before in the acousto-optic systems. It was experimentally shown that frequency locking effect may be used to select one of the multimode semiconductor laser longitudinal modes to improve laser radiation spectral composition.

  18. Engineering Optics

    CERN Document Server

    Iizuka, Keigo

    2008-01-01

    Engineering Optics is a book for students who want to apply their knowledge of optics to engineering problems, as well as for engineering students who want to acquire the basic principles of optics. It covers such important topics as optical signal processing, holography, tomography, holographic radars, fiber optical communication, electro- and acousto-optic devices, and integrated optics (including optical bistability). As a basis for understanding these topics, the first few chapters give easy-to-follow explanations of diffraction theory, Fourier transforms, and geometrical optics. Practical examples, such as the video disk, the Fresnel zone plate, and many more, appear throughout the text, together with numerous solved exercises. There is an entirely new section in this updated edition on 3-D imaging.

  19. Intense, ultrashort light and dense, hot matter

    Indian Academy of Sciences (India)

    This article presents an overview of the physics and applications of the interaction of high inten- sity laser light with matter. It traces the crucial advances that have occurred over the past few decades in laser technology and nonlinear optics and then discusses physical phenomena that occur in intense laser fields and their ...

  20. Constipation and Incident CKD.

    Science.gov (United States)

    Sumida, Keiichi; Molnar, Miklos Z; Potukuchi, Praveen K; Thomas, Fridtjof; Lu, Jun Ling; Matsushita, Kunihiro; Yamagata, Kunihiro; Kalantar-Zadeh, Kamyar; Kovesdy, Csaba P

    2017-04-01

    Constipation is one of the most prevalent conditions in primary care settings and increases the risk of cardiovascular disease, potentially through processes mediated by altered gut microbiota. However, little is known about the association of constipation with CKD. In a nationwide cohort of 3,504,732 United States veterans with an eGFR ≥60 ml/min per 1.73 m 2 , we examined the association of constipation status and severity (absent, mild, or moderate/severe), defined using diagnostic codes and laxative use, with incident CKD, incident ESRD, and change in eGFR in Cox models (for time-to-event analyses) and multinomial logistic regression models (for change in eGFR). Among patients, the mean (SD) age was 60.0 (14.1) years old; 93.2% of patients were men, and 24.7% were diabetic. After multivariable adjustments, compared with patients without constipation, patients with constipation had higher incidence rates of CKD (hazard ratio, 1.13; 95% confidence interval [95% CI], 1.11 to 1.14) and ESRD (hazard ratio, 1.09; 95% CI, 1.01 to 1.18) and faster eGFR decline (multinomial odds ratios for eGFR slope constipation associated with an incrementally higher risk for each renal outcome. In conclusion, constipation status and severity associate with higher risk of incident CKD and ESRD and with progressive eGFR decline, independent of known risk factors. Further studies should elucidate the underlying mechanisms. Copyright © 2017 by the American Society of Nephrology.

  1. Cancer incidence among firefighters

    DEFF Research Database (Denmark)

    Pukkala, Eero; Martinsen, Jan Ivar; Weiderpass, Elisabete

    2014-01-01

    .51), adenocarcinoma of the lung (SIR=1.90, 95% CI 1.34 to 2.62), and mesothelioma (SIR=2.59, 95% CI 1.24 to 4.77). By contrast with earlier studies, the incidence of testicular cancer was decreased (SIR=0.51, 95% CI 0.23 to 0.98). CONCLUSIONS: Some of these associations have been observed previously, and potential...

  2. Method and apparatus for bistable optical information storage for erasable optical disks

    Science.gov (United States)

    Land, Cecil E.; McKinney, Ira D.

    1990-01-01

    A method and an optical device for bistable storage of optical information, together with reading and erasure of the optical information, using a photoactivated shift in a field dependent phase transition between a metastable or a bias-stabilized ferroelectric (FE) phase and a stable antiferroelectric (AFE) phase in an lead lanthanum zirconate titanate (PLZT). An optical disk contains the PLZT. Writing and erasing of optical information can be accomplished by a light beam normal to the disk. Reading of optical information can be accomplished by a light beam at an incidence angle of 15 to 60 degrees to the normal of the disk.

  3. Optical bistability controlling light with light

    CERN Document Server

    Gibbs, Hyatt

    1985-01-01

    Optical Bistability: Controlling Light with Light focuses on optical bistability in nonlinear optical systems. Emphasis is on passive (non-laser) systems that exhibit reversible bistability with input intensity as the hysteresis variable, along with the physics and the potential applications of such systems for nonlinear optical signal processing. This book consists of seven chapters and begins with a historical overview of optical bistability in lasers and passive systems. The next chapter describes steady-state theories of optical bistability, including the Bonifacio-Lugiato model, as we

  4. Cancer incidence among waiters

    DEFF Research Database (Denmark)

    Reijula, Jere; Kjaerheim, Kristina; Lynge, Elsebeth

    2015-01-01

    AIMS: To study cancer risk patterns among waiters in the Nordic countries. METHODS: We identified a cohort of 16,134 male and 81,838 female waiters from Denmark, Finland, Iceland, Norway and Sweden. During the follow-up period from 1961 to 2005, we found that 19,388 incident cancer cases were...... diagnosed. Standardised incidence ratio (SIR) was defined as the observed number of cancer cases divided by the expected number, based on national age, time period and gender-specific cancer incidence rates in the general population. RESULTS: The SIR of all cancers in waiters, in the five countries combined......, was 1.46 (95% CI 1.41-1.51) in men and 1.09 (1.07-1.11) in women. In male waiters, the SIR decreased from 1.79 (1.63-1.96) in 1961-1975, to 1.33 (1.26-1.40) in 1991-2005, but remained stable among women. The SIR among male waiters was highest for cancers in the pharynx (6.11; 95% CI 5.02-7.37), oral...

  5. Contaminated Mexican steel incident

    International Nuclear Information System (INIS)

    1985-01-01

    This report documents the circumstances contributing to the inadvertent melting of cobalt 60 (Co-60) contaminated scrap metal in two Mexican steel foundries and the subsequent distribution of contaminated steel products into the United States. The report addresses mainly those actions taken by US Federal and state agencies to protect the US population from radiation risks associated with the incident. Mexico had much more serious radiation exposure and contamination problems to manage. The United States Government maintained a standing offer to provide technical and medical assistance to the Mexican Government. The report covers the tracing of the source to its origin, response actions to recover radioactive steel in the United States, and return of the contaminated materials to Mexico. The incident resulted in significant radiation exposures within Mexico, but no known significant exposure within the United States. Response to the incident required the combined efforts of the Nuclear Regulatory Commission (NRC), Department of Energy, Department of Transportation, Department of State, and US Customs Service (Department of Treasury) personnel at the Federal level and representatives of all 50 State Radiation Control Programs and, in some instances, local and county government personnel. The response also required a diplomatic interface with the Mexican Government and cooperation of numerous commercial establishments and members of the general public. The report describes the factual information associated with the event and may serve as information for subsequent recommendations and actions by the NRC. 8 figures

  6. Time-gated optical imaging through turbid media using stimulated ...

    Indian Academy of Sciences (India)

    millimeter resolution imaging without the need for ionizing radiation and associated risks [1,2]. The fundamental problem with optical imaging is that in contrast to ... intensity dependent non-linear optical gates such as the optical Kerr effect [6], dye- based optical amplifier [7] etc. Duncan et al [8] and Mahon et al [9] exploited ...

  7. Accurate measurement of microscopic forces and torques using optical tweezers

    CSIR Research Space (South Africa)

    McLaren, M

    2011-09-01

    Full Text Available It is now well known that matter may be trapped by optical fields with high intensity gradients. Once trapped, it is then possible to manipulate microscopic particles using such optical fields, in so-called optical tweezers. Such optical trapping...

  8. Correlation between optical emission spectra and the process ...

    Indian Academy of Sciences (India)

    Growth of the good quality PCD inside a MPCVD ... increase in the CH4 concentration up to 0.8% of the total gas mixture, and then the line intensities decreases with .... quality PCD growth. 2.3 Optical emission spectroscopy (OES). Optical emission spectrometer consists of sub-components like optical fibre, slit, optical filter,.

  9. Plasmas produced by incident laser in solids

    International Nuclear Information System (INIS)

    Oliveira Campos, D. de; Boeckelmann, H.K.

    1984-01-01

    The experimental arrangement for plasma production by incident laser in solids and a system of diagnostics are presented. The system of diagnostics allows: verify the plasma generation and expansion through the ultrahigh-speed photography; obtain measurements of temperature and density by spectroscopy (using an optical analyser of multichannels) and obtain measurements of kinetic energy of ions through his fly time, using a 'Faraday cup'. A vacuum system with an adsorption pump for pre-vacuum and ionic pump was used to reduce pressure and avoid mechanical vibrations and system contaminations. (M.C.K.) [pt

  10. Superhydrophobic surfaces: from fluid mechanics to optics

    NARCIS (Netherlands)

    Rathgen, H.

    2008-01-01

    In this thesis optical diraction was used to study the static and dynamic properties of microscopic liquid-gas interfaces that span between adjacent ridges of a superhydrophobic surface. An observed interference phenomenon at grazing incident angle led to the development of optical gratings with a

  11. Optical forces through guided light deflections

    DEFF Research Database (Denmark)

    Palima, Darwin; Bañas, Andrew Rafael; Vizsnyiczai, Gaszton

    2013-01-01

    . In this work we look into the object shaping aspect and its potential for controlled optical manipulation. Using a simple bent waveguide as example, our numerical simulations show that the guided deflection of light efficiently converts incident light momentum into optical force with one order...

  12. Numerical analysis of first-order acousto-optic Bragg diffraction of profiled optical beams using open-loop transfer functions

    Science.gov (United States)

    Chatterjee, Monish R.; Almehmadi, Fares S.

    2014-03-01

    In standard acousto-optic Bragg analysis, the incident light and sound beams are assumed to be uniform plane waves (with constant profiles) leading to the results based on standard weak interaction theory. As a follow-up to earlier work dealing with nonuniform incident optical beams, we revisit the problem of Bragg diffraction under nonuniform profiles, and include Gaussian, third-order Hermite-Gaussian, and zeroth-order Bessel profiles in our investigation, along with a few others. The first-order diffracted beam is examined (using a transfer function formalism based on angular spectra) under several parametric limits [such as the Klein-Cook parameter Q, the effective profile width, and the optical phase-shift parameter (α) in the sound cell]. Wherever feasible, the numerical results are compared with analytic theory. The scattered first-order profile output versus the optical phase-shift appears to maintain behavior similar to the known first-order characteristics (sin2 in intensity) encountered for the uniform incident beam case. It is observed, however, that such conformity exists seemingly only at relatively small values of Q (typically about 20 to 50). At higher Qs, on the other hand (where one would otherwise expect behavior closer to standard Bragg theory based on large Qs), it is found that the first-order intensity deviates substantially from the expected sin2- (or related) pattern. This deviation actually becomes more severe at even higher Qs. Additionally, the output profiles at higher Qs are also found to be distorted relative to the incident profiles. These results, though anomalous, are nevertheless generally compatible with earlier studies. Based on the transfer function theory, it is also known that for very large optical phase shifts (i.e., when α goes to infinity), the scattered first-order output for a Gaussian profile undergoes an axial (spatial) shift past the output plane of the sound cell. This predicted result is corroborated in our

  13. Dispersion measurement on chirped mirrors at arbitrary incidence angle and polarization state (Conference Presentation)

    Science.gov (United States)

    Kovacs, Mate; Somoskoi, Tamas; Seres, Imre; Borzsonyi, Adam; Sipos, Aron; Osvay, Károly

    2017-05-01

    The optical elements of femtosecond high peak power lasers have to fulfill more and more strict requirements in order to support pulses with high intensity and broad spectrum. In most cases chirped pulse amplification scheme is used to generate high peak power ultrashort laser pulses, where a very precise control of spectral intensity and spectral phase is required in reaching transform-limited temporal shape at the output. In the case of few cycle regime, the conventional bulk glass, prism-, grating- and their combination based compressors are not sufficient anymore, due to undesirable nonlinear effects in their material and proneness to optical damages. The chirped mirrors are also commonly used to complete the compression after a beam transport system just before the target. Moreover, the manufacturing technology requires quality checks right after production and over the lifetime of the mirror as well, since undesired deposition on the surface can lead alteration from the designed value over a large part of the aperture. For the high harmonic generation, polarization gating technology is used to generate single attosecond pulses [1]. In this case the pulse to be compressed has various polarization state falling to the chirped mirrors. For this reason, it is crucial to measure the dispersion of the mirrors for the different polarization states. In this presentation we demonstrate a simple technique to measure the dispersion of arbitrary mirror at angles of incidence from 0 to 55 degree, even for a 12" optics. A large aperture 4" mirror has been scanned over with micrometer accuracy and the dispersion property through the surface has been investigated with a stable interference fringes in that robust geometry. We used Spectrally Resolved Interferometry, which is based on a Michaelson interferometer and a combined visible and infrared spectrometer. Tungsten halogen lamp with 10 mW coupled optical power was used as a white-light source so with the selected

  14. Medication incidents reported to an online incident reporting system.

    LENUS (Irish Health Repository)

    Alrwisan, Adel

    2011-01-15

    AIMS: Approximately 20% of deaths from adverse events are related to medication incidents, costing the NHS an additional £500 million annually. Less than 5% of adverse events are reported. This study aims to assess the reporting rate of medication incidents in NHS facilities in the north east of Scotland, and to describe the types and outcomes of reported incidents among different services. Furthermore, we wished to quantify the proportion of reported incidents according to the reporters\\' profession. METHODS: A retrospective description was made of medication incidents reported to an online reporting system (DATIX) over a 46-month-period (July 2005 to April 2009). Reports originated from acute and community hospitals, mental health, and primary care facilities. RESULTS: Over the study period there were 2,666 incidents reported with a mean monthly reporting rate of 78.2\\/month (SD±16.9). 6.1% of all incidents resulted in harm, with insulin being the most commonly implicated medication. Nearly three-quarters (74.2%, n=1,978) of total incidents originated from acute hospitals. Administration incidents were implicated in the majority of the reported medication incidents (59%), followed by prescribing (10.8%) and dispensing (9.9%), while the nondescript "other medication incidents" accounted for 20.3% of total incidents. The majority of reports were made by nursing and midwifery staff (80%), with medical and dental professionals reporting the lowest number of incidents (n=56, 2%). CONCLUSIONS: The majority of medication incidents in this study were reported by nursing and midwifery staff, and were due to administration incidents. There is a clear need to elucidate the reasons for the limited contribution of the medical and dental professionals to reporting medication incidents.

  15. Light Intensity Influence on the Effective Schottky Barrier Height in Extraordinary Optoconductance (EOC) Structures

    Science.gov (United States)

    Werner, F. M.; Tran, L. C.; Solin, S. A.

    2013-03-01

    Novel micro to nanoscale metal-semiconductor-hybrid (MSH) structures capable of room temperature light detection have been previously reported and classified as Extraordinary Optoconductance (EOC) devices. The devices are square stacked structures, with a Au-Ti shunt forming a Schottky-Interface with an n-doped Ga-As mesa. Resistance measurements were taken by a 4-point van-der Pauw method to remove contact and lead resistance and eliminate DC offsets. The device's resistance changes as light incident on the surface of the structure modifies the charge density within the body of the device. The change in charge density changes the effective Schottky Barrier height and shifts the measured 4 point resistance of the heterogeneous structure. We investigate the dependence of the effective Schottky Barrier height on the incident intensity of light by measuring the open circuit voltage under various intensities of optical perturbation at room temperature. The barrier height is negligible and the interface ohmic under HeNe laser 632.8 nm illumination at a power density of 636 mW/cm2, allowing the flow of current through the shunt. This device performance will be contrasted with that of an FET, where current does not propagate through the gate. SAS has a financial interest in PixelEXX, a start-up company whose mission is to market imaging arrays.

  16. Experimental Study on Light Flash Radiant Intensity Generated by Strong Shock 2A12 Aluminum Plate

    Science.gov (United States)

    Tang, Enling; Zhang, Lijiao; Zhang, Qingming; Shi, Xiaohan; Wang, Meng; Wang, Di; Xiang, Shenghai; Xia, Jin; Han, Yafei; Xu, Mingyang; Wu, Jin; Zhang, Shuang; Yuan, Jianfei

    2015-07-01

    In order to study the light flash radiant intensity produced by strong shock on a 2A12 aluminum target at the same projectile incidence angles and different shock velocities, experimental measurements were conducted for light flash phenomena of a 2A12 aluminum projectile impacting a 2A12 aluminum target under the conditions of different impact velocity and the same projectile incidence angles of 45° by using an optical pyrometer measurement system and a two-stage light gas gun loading system. Experimental results show that the peak values of the light flash radiant intensity for the wavelength of 550 nm are largest in the wavelength ranges of 600 nm, 650 nm and 700 nm when a 2A12 aluminum projectile impacts a double-layer 2A12 aluminum plate in the present experimental conditions. supported by National Natural Science Foundation of China (Nos. 10972145, 11272218, 11472178), State Key Program of National Natural Science of China (No. 11032003), Program for Liaoning Excellent Talents in University, China (No. LR2013008)

  17. Applied optics

    International Nuclear Information System (INIS)

    Orszag, A.; Antonetti, A.

    1988-01-01

    The 1988 progress report, of the Applied Optics laboratory, of the (Polytechnic School, France), is presented. The optical fiber activities are focused on the development of an optical gyrometer, containing a resonance cavity. The following domains are included, in the research program: the infrared laser physics, the laser sources, the semiconductor physics, the multiple-photon ionization and the nonlinear optics. Investigations on the biomedical, the biological and biophysical domains are carried out. The published papers and the congress communications are listed [fr

  18. Hamilton's Optics

    Indian Academy of Sciences (India)

    IAS Admin

    Hamiton, optics, wavefronts, characterisic function, conical refraction. . Hamilton's Optics. The Power of Wavefronts. Rajaram Nityananada. Building on work by Fermat and Huygens, Hamil- ton transformed the study of geometrical optics in his very first paper, presented when still in his teens. His 'characteristic function' was ...

  19. Beam conditioning multilayer optics for laboratory x-ray sources

    Science.gov (United States)

    Platonov, Yuriy; Verman, Boris; Jiang, Licai; Kim, Bonglea

    2015-08-01

    Practically, all modern x-ray diffractometers, SAXS, TXRF systems and many other laboratory X-ray instruments are equipped with multilayer X-ray optics. It is due to a much higher flux these instruments have comparing with those having no optics or having a grazing incidence optics without multilayer coatings. There are variety of the multilayer optics designs - from one bounce collimating parabolic mirror to four corners double bounce focusing mirrors. Design of multilayer optics depends on application, X-ray source parameters, requirements on divergence, focal spot, available room for the optics, manufacturing capability and cost. Key characteristics of the optics, requirements on multilayers d-spacing accuracy, optics slope errors, and substrates surface roughness are discussed in the paper. Different optics designs are considered including recently developed optics for a laboratory topography system and a Hybrid optics combining multilayer and crystal optics for XRR and XRD.

  20. Incident users of antipsychotics

    DEFF Research Database (Denmark)

    Baandrup, Lone; Kruse, Marie

    2016-01-01

    PURPOSE: In Denmark, as well as in many other countries, consumption of antipsychotics is on the rise, partly due to increasing off-label use. The aim of this study was to analyze and quantify the extent of off-label use and polypharmacy in incident users of antipsychotic medication, and to examine...... initial antipsychotic prescribing patterns and associated use of mental health care services. METHOD: Population-based cohort study linking the following Danish national registers: the Central Psychiatric Research Register, the Register of Medicinal Product Statistics, and Statistics Denmark. RESULTS...

  1. Optimized systems for energy efficient optical tweezing

    Science.gov (United States)

    Kampmann, R.; Kleindienst, R.; Grewe, A.; Bürger, Elisabeth; Oeder, A.; Sinzinger, S.

    2013-03-01

    Compared to conventional optics like singlet lenses or even microscope objectives advanced optical designs help to develop properties specifically useful for efficient optical tweezers. We present an optical setup providing a customized intensity distribution optimized with respect to large trapping forces. The optical design concept combines a refractive double axicon with a reflective parabolic focusing mirror. The axicon arrangement creates an annular field distribution and thus clears space for additional integrated observation optics in the center of the system. Finally the beam is focused to the desired intensity distribution by a parabolic ring mirror. The compact realization of the system potentially opens new fields of applications for optical tweezers such as in production industries and micro-nano assembly.

  2. Broadband optical modulators based on graphene supercapacitors.

    Science.gov (United States)

    Polat, Emre O; Kocabas, Coskun

    2013-01-01

    Optical modulators are commonly used in communication and information technology to control intensity, phase, or polarization of light. Electro-optic, electroabsorption, and acousto-optic modulators based on semiconductors and compound semiconductors have been used to control the intensity of light. Because of gate tunable optical properties, graphene introduces new potentials for optical modulators. The operation wavelength of graphene-based modulators, however, is limited to infrared wavelengths due to inefficient gating schemes. Here, we report a broadband optical modulator based on graphene supercapacitors formed by graphene electrodes and electrolyte medium. The transparent supercapacitor structure allows us to modulate optical transmission over a broad range of wavelengths from 450 nm to 2 μm under ambient conditions. We also provide various device geometries including multilayer graphene electrodes and reflection type device geometries that provide modulation of 35%. The graphene supercapacitor structure together with the high-modulation efficiency can enable various active devices ranging from plasmonics to optoelectronics.

  3. Improving freight crash incident management.

    Science.gov (United States)

    2015-06-01

    The objective of this study was to determine the most effective way to mitigate the effect of freight : crash incidents on Louisiana freeways. Candidate incident management strategies were reviewed from : practice in other states and from those publi...

  4. Common Causes of Pesticide Incidents

    Science.gov (United States)

    There are many types of pesticide incidents. EPA staff analyze pesticide incident reports involving people (including children and farm workers), pets, domestic animals, wildlife including bees and other pollinators, and the environment.

  5. Phase-Modulated Optical Communication Systems

    CERN Document Server

    Ho, Keang-Po

    2005-01-01

    Fiber-optic communication systems have revolutionized our telecommunication infrastructures – currently, almost all telephone land-line, cellular, and internet communications must travel via some form of optical fibers. In these transmission systems, neither the phase nor frequency of the optical signal carries information – only the intensity of the signal is used. To transmit more information in a single optical carrier, the phase of the optical carrier must be explored. As a result, there is renewed interest in phase-modulated optical communications, mainly in direct-detection DPSK signals for long-haul optical communication systems. When optical amplifiers are used to maintain certain signal level among the fiber link, the system is limited by amplifier noises and fiber nonlinearities. Phase-Modulated Optical Communication Systems surveys this newly popular area, covering the following topics: The transmitter and receiver for phase-modulated coherent lightwave systems Method for performance analysis o...

  6. Optics equations for aero-optical analysis

    Science.gov (United States)

    Sutton, George W.; Pond, John E.

    2011-05-01

    Aero-optical effects occur around moving air vehicles and impact passive imaging or active systems. The air flow around the vehicle is compressed, and often there is a turbulent shear and/or boundary layer both of which cause variations in the index of refraction. Examples of these are reconnaissance aircraft, the Stratospheric Observatory for Infrared Optics (SOFIA), and optically homing hypersonic interceptors. In other applications, a laser beam can be formed within the vehicle, and projected outward and focused on an object. These include the Airborne Laser Laboratory, Airborne Laser and the Airborne Tactical Laser. There are many compressible fluid mechanics computer programs that can predict the air density distribution of the surrounding flow field including density fluctuations in turbulent shear and/or boundary layers. It is necessary for the physical optics to be used to predict the properties of the ensuing image plane intensity distribution, whether passive or active. These include the time-averaged image blur circle and instantaneous realizations. (Ray tracing is a poor approximation that gives erroneous results for small aberrations.)

  7. Increasing incidence of pyogenic spondylodiscitis

    DEFF Research Database (Denmark)

    Kehrer, Michala; Pedersen, Court; Jensen, Thøger G

    2014-01-01

    Smaller studies indicate that the incidence of pyogenic spondylodiscitis is increasing, possible related to a growing elderly population. Data supporting this is sparse, and we therefore studied patient characteristics and changes in spondylodiscitis incidence 1995-2008.......Smaller studies indicate that the incidence of pyogenic spondylodiscitis is increasing, possible related to a growing elderly population. Data supporting this is sparse, and we therefore studied patient characteristics and changes in spondylodiscitis incidence 1995-2008....

  8. Nonlinear optics

    CERN Document Server

    Boyd, Robert W

    2013-01-01

    Nonlinear Optics is an advanced textbook for courses dealing with nonlinear optics, quantum electronics, laser physics, contemporary and quantum optics, and electrooptics. Its pedagogical emphasis is on fundamentals rather than particular, transitory applications. As a result, this textbook will have lasting appeal to a wide audience of electrical engineering, physics, and optics students, as well as those in related fields such as materials science and chemistry.Key Features* The origin of optical nonlinearities, including dependence on the polarization of light* A detailed treatment of the q

  9. Optical fibres

    CERN Document Server

    Geisler, J; Boutruche, J P

    1986-01-01

    Optical Fibers covers numerous research works on the significant advances in optical fibers, with particular emphasis on their application.This text is composed of three parts encompassing 15 chapters. The first part deals with the manufacture of optical fibers and the materials used in their production. The second part describes optical-fiber connectors, terminals and branches. The third part is concerned with the major optoelectronic components encountered in optical-communication systems.This book will be of value to research scientists, engineers, and patent workers.

  10. Optical interconnects

    CERN Document Server

    Chen, Ray T

    2006-01-01

    This book describes fully embedded board level optical interconnect in detail including the fabrication of the thin-film VCSEL array, its characterization, thermal management, the fabrication of optical interconnection layer, and the integration of devices on a flexible waveguide film. All the optical components are buried within electrical PCB layers in a fully embedded board level optical interconnect. Therefore, we can save foot prints on the top real estate of the PCB and relieve packaging difficulty reduced by separating fabrication processes. To realize fully embedded board level optical

  11. Atom optics

    International Nuclear Information System (INIS)

    Balykin, V. I.; Jhe, W.

    1999-01-01

    Atom optics, in analogy to neutron and electron optics, deals with the realization of as a traditional elements, such as lenes, mirrors, beam splitters and atom interferometers, as well as a new 'dissipative' elements such as a slower and a cooler, which have no analogy in an another types of optics. Atom optics made the development of atom interferometer with high sensitivity for measurement of acceleration and rotational possible. The practical interest in atom optics lies in the opportunities to create atom microprobe with atom-size resolution and minimum damage of investigated objects. (Cho, G. S.)

  12. Regeneration of Optic Nerve

    Directory of Open Access Journals (Sweden)

    Kwok-Fai So

    2011-05-01

    Full Text Available The optic nerve is part of the central nervous system (CNS and has a structure similar to other CNS tracts. The axons that form the optic nerve originate in the ganglion cell layer of the retina and extend through the optic tract. As a tissue, the optic nerve has the same organization as the white matter of the brain in regard to its glia. There are three types of glial cells: Oligodendrocytes, astrocytes, and microglia. Little structural and functional regeneration of the CNS takes place spontaneously following injury in adult mammals. In contrast, the ability of the mammalian peripheral nervous system (PNS to regenerate axons after injury is well documented. A number of factors are involved in the lack of CNS regeneration, including: (i the response of neuronal cell bodies against the damage; (ii myelin-mediated inhibition by oligodendrocytes; (iii glial scarring, by astrocytes; (iv macrophage infiltration; and (v insufficient trophic factor support. The fundamental difference in the regenerative capacity between CNS and PNS neuronal cell bodies has been the subject of intensive research. In the CNS the target normally conveys a retrograde trophic signal to the cell body. CNS neurons die because of trophic deprivation. Damage to the optic nerve disconnects the neuronal cell body from its target-derived trophic peptides, leading to the death of retinal ganglion cells. Furthermore, the axontomized neurons become less responsive to the peptide trophic signals they do receive. On the other hand, adult PNS neurons are intrinsically responsive to neurotrophic factors and do not lose trophic responsiveness after axotomy. In this talk different strategies to promote optic-nerve regeneration in adult mammals are reviewed. Much work is still needed to resolve many issues. This is a very important area of neuroregeneration and neuroprotection, as currently there is no cure after traumatic optic nerve injury or retinal disease such as glaucoma, which

  13. Incident Management: Process into Practice

    Science.gov (United States)

    Isaac, Gayle; Moore, Brian

    2011-01-01

    Tornados, shootings, fires--these are emergencies that require fast action by school district personnel, but they are not the only incidents that require risk management. The authors have introduced the National Incident Management System (NIMS) and the Incident Command System (ICS) and assured that these systems can help educators plan for and…

  14. Iowa Intensive Archaeological Survey

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This shape file contains intensive level archaeological survey areas for the state of Iowa. All intensive Phase I surveys that are submitted to the State Historic...

  15. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... for a breath. Absolute Intensity The amount of energy used by the body per minute of activity. ... or vigorous-intensity based upon the amount of energy used by the body while doing the activity. ...

  16. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... using relative intensity, people pay attention to how physical activity affects their heart rate and breathing. The talk test is a simple way to measure relative intensity. ...

  17. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart Rate & Estimated Maximum Heart Rate Perceived Exertion ( ... a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived ...

  18. Optical spectroscopy and tooth decay

    Science.gov (United States)

    Misra, P.; De, T.; Singh, R.

    2005-11-01

    Optical spectroscopy in the ultraviolet, visible and mid-infrared spectral regions has been used to discriminate between healthy and diseased teeth of patients in the age range 15-75 years. Spectral scans of absorbance versus wavenumber and fluorescence intensity versus wavelength have been recorded and investigated for caries and periodontal disease. Such optical diagnostics can prove very useful in the early detection and treatment of tooth decay.

  19. What is refractive optical bistability

    International Nuclear Information System (INIS)

    Dzhehov, Tomislav

    1993-01-01

    The basic elements of the theory of refractive optical bistability, assuming mediums with linear absorption are given. Special attention is paid to bistable etalons of semiconductor materials an oxide glasses, since some of them are considered as promising components for optical bistability applications. The design optimization of such devices for minimum switching intensity is analyzed. Computer simulation of the transfer characteristic recording for two InSb etalons is presented. (author)

  20. Radiation produced by electrons incident on molecules

    International Nuclear Information System (INIS)

    Moehlman, G.R.

    1977-01-01

    The work described in this thesis deals with light intensity measurements of emission spectra (1850-9000 A) produced by a continuous or pulsed beam of monoenergetic electrons (0 - 2000 eV) incident on a variety of molecular gases like H 2 , D 2 , H 2 O, HCl, NH 3 and several hydrocarbons. The emission spectra are dominated by fluorescence from excited fragments produced via dissociative excitation, besides fluorescence from excited parent molecules themselves. The experimental results thus obtained are expressed in terms of emission cross sections and lifetimes

  1. Film thickness determination by grazing incidence diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Battiston, G. A.; Gerbasi, R. [CNR, Padua (Italy). Istituto di Chimica e Tecnologie Inorganiche e dei Materiali Avanzati

    1996-09-01

    Thin films deposited via MOCVD (Metal Organic Chemical Vapour Deposition) are layers in the thickness range of a few manometers to about ten micrometers. An understanding of the physics and chemistry of films is necessary for a better comprehension of the phenomena involved in the film deposition procedure and its optimisation. Together with the crystalline phase a parameter that must be determined is the thickness of the layer. In this work the authors present a method for the measurement of the film thickness. This procedure, based on diffraction intensity absorption of the X-rays, both incident and diffracted in passing through the layers, resulted quite simple, rapid and non-destructive.

  2. Stochastic conditional intensity processes

    DEFF Research Database (Denmark)

    Bauwens, Luc; Hautsch, Nikolaus

    2006-01-01

    In this article, we introduce the so-called stochastic conditional intensity (SCI) model by extending Russell’s (1999) autoregressive conditional intensity (ACI) model by a latent common dynamic factor that jointly drives the individual intensity components. We show by simulations that the propos...... for a joint latent factor and show that its inclusion allows for an improved and more parsimonious specification of the multivariate intensity process...

  3. Rainfed intensive crop systems

    DEFF Research Database (Denmark)

    Olesen, Jørgen E

    2014-01-01

    This chapter focuses on the importance of intensive cropping systems in contributing to the world supply of food and feed. The impact of climate change on intensive crop production systems is also discussed.......This chapter focuses on the importance of intensive cropping systems in contributing to the world supply of food and feed. The impact of climate change on intensive crop production systems is also discussed....

  4. Optical transitions in semiconductor nanospherical core/shell/shell heterostructure in the presence of radial electrostatic field

    Energy Technology Data Exchange (ETDEWEB)

    Baghdasaryan, D.A. [Russian-Armenian University, H. Emin 123, 0051 Yerevan (Armenia); Hayrapetyan, D.B., E-mail: dhayrap82@gmail.com [Russian-Armenian University, H. Emin 123, 0051 Yerevan (Armenia); Yerevan State University, A. Manoogian 1, 0025 Yerevan (Armenia); Harutyunyan, V.A. [Russian-Armenian University, H. Emin 123, 0051 Yerevan (Armenia)

    2017-04-01

    The electronic states and optical properties of spherical nanolayer in the presence of the electrostatic radial field in the strong size quantization regime have been considered. Both analytical and numerical methods have been applied to the problem of one-electron states in the system. According to the intensity of the external electrostatic field, three regimes have been distinguished: week, intermediate and strong. Perturbative approach have been applied to the case of week, WKB to the case of intermediate and variation approach to the case of strong field intensities. The analytical dependencies of the one electron energy and wave function on the electric field value and geometrical parameters of the nanolayer have been achieved. The comparison of the results obtained by the analytical method with the results of the numerical method have been made. The interband and intraband optical transitions caused by incident optical light polarized in z direction have been considered in this system. The selection rules for this transitions have been obtained. The dependence of the absorption coefficient on the energy of incident light for both cases of interband and intraband transitions for every regime of the electrostatic field value have been received. - Highlights: • The electron energy analytical dependencies on the electric field value have been achieved. • The selection rules for transitions between levels with different quantum numbers are revealed. • The interband and intraband absorption coefficients have been studied.

  5. Applied optics and optical design

    CERN Document Server

    Conrady, Alexander Eugen

    1957-01-01

    ""For the optical engineer it is an indispensable work."" - Journal, Optical Society of America""As a practical guide this book has no rival."" - Transactions, Optical Society""A noteworthy contribution,"" - Nature (London)Part I covers all ordinary ray-tracing methods, together with the complete theory of primary aberrations and as much of higher aberration as is needed for the design of telescopes, low-power microscopes and simple optical systems. Chapters: Fundamental Equations, Spherical Aberration, Physical Aspect of Optical Images, Chromatic Aberration, Design of Achromatic Object-Glass

  6. Analgesia, sedation, and memory of intensive care.

    Science.gov (United States)

    Capuzzo, M; Pinamonti, A; Cingolani, E; Grassi, L; Bianconi, M; Contu, P; Gritti, G; Alvisi, R

    2001-09-01

    The purpose of this article was to investigate the relationship between analgesia, sedation, and memory of intensive care. One hundred fifty-two adult, cooperative intensive care unit (ICU) patients were interviewed 6 months after hospital discharge about their memory of intensive care. The patient was considered to be cooperative when he/she was aware of self and environment at the interview. The patients were grouped as follows: A (45 patients) substantially no sedation, B (85) morphine, and C (22) morphine and other sedatives. The patients having no memory of intensive care were 38%, 34%, and 23% respectively, in the three groups. They were less ill, according to SAPS II (P memories was not different among the three groups. Females reported at least one emotional memory more frequently than males (odds ratio 4.17; 95% CI 10.97-1.59). The patients receiving sedatives in the ICU are not comparable with those receiving only opiates or nothing, due to the different clinical condition. The lack of memory of intensive care is present in one third of patients and is influenced more by length of stay in ICU than by the sedation received. Sedation does not influence the incidence of factual, sensation, and emotional memories of ICU admitted patients. Females have higher incidences of emotional memories than males. Copyright 2001 by W.B. Saunders Company

  7. Solar cell angle of incidence corrections

    Science.gov (United States)

    Burger, Dale R.; Mueller, Robert L.

    1995-01-01

    Literature on solar array angle of incidence corrections was found to be sparse and contained no tabular data for support. This lack along with recent data on 27 GaAs/Ge 4 cm by 4 cm cells initiated the analysis presented in this paper. The literature cites seven possible contributors to angle of incidence effects: cosine, optical front surface, edge, shadowing, UV degradation, particulate soiling, and background color. Only the first three are covered in this paper due to lack of sufficient data. The cosine correction is commonly used but is not sufficient when the incident angle is large. Fresnel reflection calculations require knowledge of the index of refraction of the coverglass front surface. The absolute index of refraction for the coverglass front surface was not known nor was it measured due to lack of funds. However, a value for the index of refraction was obtained by examining how the prediction errors varied with different assumed indices and selecting the best fit to the set of measured values. Corrections using front surface Fresnel reflection along with the cosine correction give very good predictive results when compared to measured data, except there is a definite trend away from predicted values at the larger incident angles. This trend could be related to edge effects and is illustrated by a use of a box plot of the errors and by plotting the deviation of the mean against incidence angle. The trend is for larger deviations at larger incidence angles and there may be a fourth order effect involved in the trend. A chi-squared test was used to determine if the measurement errors were normally distributed. At 10 degrees the chi-squared test failed, probably due to the very small numbers involved or a bias from the measurement procedure. All other angles showed a good fit to the normal distribution with increasing goodness-of-fit as the angles increased which reinforces the very small numbers hypothesis. The contributed data only went to 65 degrees

  8. An automatic analyzer of solid state nuclear track detectors using an optic RAM as image sensor

    International Nuclear Information System (INIS)

    Staderini, E.M.; Castellano, A.

    1986-01-01

    An optic RAM is a conventional digital random access read/write dynamic memory device featuring a quartz windowed package and memory cells regularly ordered on the chip. Such a device is used as an image sensor because each cell retains data stored in it for a time depending on the intensity of the light incident on the cell itself. The authors have developed a system which uses an optic RAM to acquire and digitize images from electrochemically etched CR39 solid state nuclear track detectors (SSNTD) in the track count rate up to 5000 cm -2 . On the digital image so obtained, a microprocessor, with appropriate software, performs image analysis, filtering, tracks counting and evaluation. (orig.)

  9. A broadly tunable autocorrelator for ultra-short, ultra-high power infrared optical pulses

    Energy Technology Data Exchange (ETDEWEB)

    Szarmes, E.B.; Madey, J.M.J. [Duke Univ., Durham, NC (United States)

    1995-12-31

    We describe the design of a crossed-beam, optical autocorrelator that uses an uncoated, birefringent beamsplitter to split a linearly polarized incident pulse into two orthogonally polarized pulses, and a Type II, SHG crystal to generate the intensity autocorrelation function. The uncoated beamsplitter accommodates extremely broad tunability while precluding any temporal distortion of ultrashort optical pulses at the dielectric interface, and the specific design provides efficient operation between 1 {mu}m and 4 {mu}m. Furthermore, the use of Type II SHG completely eliminates any single-beam doubling, so the autocorrelator can be operated at very shallow crossed-beam angles without generating a background pedestal. The autocorrelator has been constructed and installed in the Mark III laboratory at Duke University as a broadband diagnostic for ongoing compression experiments on the chirped-pulse FEL.

  10. [Pathomorphologic findings following intensive therapy].

    Science.gov (United States)

    Ruchti, C

    1986-05-24

    Based on autopsy findings in 301 adults who had died after intensive care, different patterns of single or multiple organ damage were identified. Signs of septicemia and/or exudative-to-fibrosing alveolitis (EFA) of the lungs, the prominent cause of the adult respiratory distress syndrome (ARDS), were recognized in 89 cases. Severe, progressive EFA, which appears to ensue mainly from continuing damage to alveolar walls, consequent fibroblast proliferation and so-called atelectatic induration (collapsed alveoli forming single thick septa), was registered only in individuals who had undergone long-term intensive care. The latter was necessitated in various severe conditions of which abdominal disease was the most important. Systemic disorders, such as hemorrhagic diathesis and multiple organ damage ("multiple organ failure"), showed a close correlation with septicemia. Infections with gram-negative bacteria appear to play a special role in such processes. Morphologically, these cases were characterized by multiple organ/system damage, e.g., in order of frequency, partial necrosis of renal proximal tubules, followed by signs of regeneration; jaundice; splenitis; lobular pneumonia; centrolobular-to-zonal liver necrosis, in part combined with cholestasis; petechial and/or extended hemorrhage; and others. This complex pattern contrasted strongly with findings in individuals who had been admitted to intensive care because of e.g. a cardiovascular incident: in this latter group (125 cases) intensive care was usually of short duration, progressive EFA was largely absent, signs of septicemia were exceptional, and multiple organ/system damage was rare. The group with polytraumatism (28 cases) exhibited a pattern of organ damage intermediate between (a) and (b).

  11. Grazing incidence X-ray fluorescence analysis of buried interfaces in periodically structured crystalline silicon thin-film solar cells

    International Nuclear Information System (INIS)

    Eisenhauer, David; Preidel, Veit; Becker, Christiane; Pollakowski, Beatrix; Beckhoff, Burkhard; Baumann, Jonas; Kanngiesser, Birgit; Amkreutz, Daniel; Rech, Bernd; Back, Franziska; Rudigier-Voigt, Eveline

    2015-01-01

    We present grazing incidence X-ray fluorescence (GIXRF) experiments on 3D periodically textured interfaces of liquid phase crystallized silicon thin-film solar cells on glass. The influence of functional layers (SiO x or SiO x /SiC x ) - placed between glass substrate and silicon during crystallization - on the final carbon and oxygen contaminations inside the silicon was analyzed. Baring of the buried structured silicon surface prior to GIXRF measurement was achieved by removal of the original nano-imprinted glass substrate by wet-chemical etching. A broad angle of incidence distribution was determined for the X-ray radiation impinging on this textured surface. Optical simulations were performed in order to estimate the incident radiation intensity on the structured surface profile considering total reflection and attenuation effects. The results indicate a much lower contamination level for SiO x compared to the SiO x /SiC x interlayers, and about 25% increased contamination when comparing structured with planar silicon layers, both correlating with the corresponding solar cell performances. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Interferometric optical vortex array generator.

    Science.gov (United States)

    Vyas, Sunil; Senthilkumaran, P

    2007-05-20

    Two new interferometric configurations for optical vortex array generation are presented. These interferometers are different from the conventional interferometers in that they are capable of producing a large number of isolated zeros of intensity, and all of them contain optical vortices. Simulation and theory for optical vortex array generation using three-plane-wave interference is presented. The vortex dipole array produced this way is noninteracting, as there are no attraction or repulsion forces between them, leading to annihilation or creation of vortex pairs.

  13. Grazing-incidence optical magnetic recording with super-resolution

    OpenAIRE

    Gunther Scheunert; Sidney. R. Cohen; René Kullock; Ryan McCarron; Katya Rechev; Ifat Kaplan-Ashiri; Ora Bitton; Paul Dawson; Bert Hecht; Dan Oron

    2017-01-01

    Heat-assisted magnetic recording (HAMR) is often considered the next major step in the storage industry: it is predicted to increase the storage capacity, the read/write speed and the data lifetime of future hard disk drives. However, despite more than a decade of development work, the reliability is still a prime concern. Featuring an inherently fragile surface-plasmon resonator as a highly localized heat source, as part of a near-field transducer (NFT), the current industry concepts still f...

  14. Optical observations geomagnetically conjugate to sprite-producing lightning discharges

    Directory of Open Access Journals (Sweden)

    R. A. Marshall

    2005-09-01

    Full Text Available Theoretical studies have predicted that large positive cloud-to-ground discharges can trigger a runaway avalanche process of relativistic electrons, forming a geomagnetically trapped electron beam. The beam may undergo pitch angle and energy scattering during its traverse of the Earth's magnetosphere, with a small percentage of electrons remaining in the loss cone and precipitating in the magnetically conjugate atmosphere. In particular, N2 1P and N2+1N optical emissions are expected to be observable. In July and August 2003, an attempt was made to detect these optical emissions, called "conjugate sprites", in correlation with sprite observations in Europe near . Sprite observations were made from the Observatoire du Pic du Midi (OMP in the French Pyrenées, and VLF receivers were installed in Europe to detect causative sferics and ionospheric disturbances associated with sprites. In the Southern Hemisphere conjugate region, the Wide-angle Array for Sprite Photometry (WASP was deployed at the South African Astronomical Observatory (SAAO, near Sutherland, South Africa, to observe optical emissions with a field-of-view magnetically conjugate to the Northern Hemisphere observing region. Observations at OMP revealed over 130 documented sprites, with WASP observations covering the conjugate region successfully for 30 of these events. However, no incidences of optical emissions in the conjugate hemisphere were found. Analysis of the conjugate optical data from SAAO, along with ELF energy measurements from Palmer Station, Antarctica, and charge-moment analysis, show that the lightning events during the course of this experiment likely had insufficient intensity to create a relativistic beam. Keywords. Ionosphere (Ionsophere-magnetosphere interactions; Ionospheric disturbances; Instruments and techniques

  15. Solar optical codes evaluation for modeling and analyzing complex solar receiver geometries

    Science.gov (United States)

    Yellowhair, Julius; Ortega, Jesus D.; Christian, Joshua M.; Ho, Clifford K.

    2014-09-01

    Solar optical modeling tools are valuable for modeling and predicting the performance of solar technology systems. Four optical modeling tools were evaluated using the National Solar Thermal Test Facility heliostat field combined with flat plate receiver geometry as a benchmark. The four optical modeling tools evaluated were DELSOL, HELIOS, SolTrace, and Tonatiuh. All are available for free from their respective developers. DELSOL and HELIOS both use a convolution of the sunshape and optical errors for rapid calculation of the incident irradiance profiles on the receiver surfaces. SolTrace and Tonatiuh use ray-tracing methods to intersect the reflected solar rays with the receiver surfaces and construct irradiance profiles. We found the ray-tracing tools, although slower in computation speed, to be more flexible for modeling complex receiver geometries, whereas DELSOL and HELIOS were limited to standard receiver geometries such as flat plate, cylinder, and cavity receivers. We also list the strengths and deficiencies of the tools to show tool preference depending on the modeling and design needs. We provide an example of using SolTrace for modeling nonconventional receiver geometries. The goal is to transfer the irradiance profiles on the receiver surfaces calculated in an optical code to a computational fluid dynamics code such as ANSYS Fluent. This approach eliminates the need for using discrete ordinance or discrete radiation transfer models, which are computationally intensive, within the CFD code. The irradiance profiles on the receiver surfaces then allows for thermal and fluid analysis on the receiver.

  16. Extended optical theorem in isotropic solids and its application to the elastic radiation force

    Science.gov (United States)

    Leão-Neto, J. P.; Lopes, J. H.; Silva, G. T.

    2017-04-01

    In this article, we derive the extended optical theorem for the elastic-wave scattering by a spherical inclusion (with and without absorption) in a solid matrix. This theorem expresses the extinction cross-section, i.e., the time-averaged power extracted from the incoming beam per its intensity, regarding the partial-wave expansion coefficients of the incident and scattered waves. We also establish the connection between the optical theorem and the elastic radiation force by a plane wave in a linear and isotropic solid. We obtain the absorption, scattering, and extinction efficiencies (the corresponding power per characteristic incident intensity per sphere cross-section area) for a plane wave and a spherically focused beam. We discuss to which extent the radiation force theory for plane waves can be used to the focused beam case. Considering an iron sphere embedded in an aluminum matrix, we numerically compute the scattering and elastic radiation force efficiencies. The radiation force on a stainless steel sphere embedded in a tissue-like medium (soft solid) is also computed. In this case, resonances are observed in the force as a function of the sphere size parameter (the wavenumber times the sphere radius). Remarkably, the relative difference between our findings and previous lossless liquid models is about 100% in the long-wavelength limit. Regarding some applications, the obtained results have a direct impact on ultrasound-based elastography techniques and ultrasonic nondestructive testing, as well as implantable devices activated by ultrasound.

  17. Morphological and Optical Characterization of High Density Au/PAA Nanoarrays

    Directory of Open Access Journals (Sweden)

    Mohamed Shaban

    2016-01-01

    Full Text Available Hexagonal nanoarrays of Au nanorods and nanopillar were deposited on nanoporous anodic alumina (PAA membranes utilizing dc electrodeposition. The surface morphologies and optical properties were characterized by using field emission-scanning electron microscopy (FE-SEM and UV-Vis spectrophotometer, respectively. The optical reflectance spectra of the as-prepared, pore widened, and 2D-Au nanorods-coated PAA membranes were studied in detail. The effects of the angle of incident, pore widening time, and electrodeposition time on the characteristic peaks positions and intensities of the fabricated nanoarrays were addressed. As the angle of incident increased, the interference peaks and transverse surface resonance are shifted to longer wavelengths, but the longitudinal surface plasmon resonance is shifted to shorter wavelengths. Also, the reflected intensities are decreased linearly for the as-prepared sample and decreased exponentially for Au/PAA samples. Using the modified Kubelka-Munk radiative transfer model, the energy gap is increased from 2.83 to 3.06 eV and the refractive index is decreased from 1.84 to 1.36 for the as-prepared and 70 min pore widened PAA membranes, respectively. Based on the advantages of the fabrication approach and the enhanced and controlled properties, this generation of Au/PAA arrays can be used as efficient building blocks for nanoelectronics and nanophotonic devices.

  18. Optical hiding with visual cryptography

    Science.gov (United States)

    Shi, Yishi; Yang, Xiubo

    2017-11-01

    We propose an optical hiding method based on visual cryptography. In the hiding process, we convert the secret information into a set of fabricated phase-keys, which are completely independent of each other, intensity-detected-proof and image-covered, leading to the high security. During the extraction process, the covered phase-keys are illuminated with laser beams and then incoherently superimposed to extract the hidden information directly by human vision, without complicated optical implementations and any additional computation, resulting in the convenience of extraction. Also, the phase-keys are manufactured as the diffractive optical elements that are robust to the attacks, such as the blocking and the phase-noise. Optical experiments verify that the high security, the easy extraction and the strong robustness are all obtainable in the visual-cryptography-based optical hiding.

  19. Circular Intensity Differential Scattering of chiral molecules

    Energy Technology Data Exchange (ETDEWEB)

    Bustamante, C.J.

    1980-12-01

    In this thesis a theory of the Circular Intensity Differential Scattering (CIDS) of chiral molecules as modelled by a helix oriented with respect to the direction of incidence of light is presented. It is shown that a necessary condition for the existence of CIDS is the presence of an asymmetric polarizability in the scatterer. The polarizability of the scatterer is assumed generally complex, so that both refractive and absorptive phenomena are taken into account.

  20. Optically-gated Non-latched High Gain Power Device

    Science.gov (United States)

    2008-11-21

    switching times of an optically-controlled power bipolar junction transistor ( BJT ) is reported in [20] using light-emitting diode (LED)-phototransistor pair...GaAs based optically-trigegred power transistor (OTPT) has been developed for fast, repetitive, non-latched switching and control of power...OF OPTICAL INTENSITY MODULATION 8 2.1. Optically-triggered power transistor structure 9 2.2 On-state resistance (Ron) of OTPT modulated by optical

  1. Conjugated Molecules for the Smart Filtering of Intense Radiations

    Directory of Open Access Journals (Sweden)

    Danilo Dini

    2003-04-01

    Full Text Available Abstract: The practical realization of smart optical filters, i.e. devices which change their optical transmission in a suitable way to keep a working state for a general light sensitive element , can involve the use of conjugated molecules whose light absorption properties are light- intensity dependent (nonlinear optical effect. The verification of optical limiting displayed by some particular conjugated molecules, e.g. phthalocyanines, is quite noteworthy and can be successfully exploited for the realization of such smart optical devices. In the present contribution the analysis of the relevant molecular feature of a phthalocyanine are analyzed with the aim of determining useful correlations between optical limiting performance and phthalocyanine chemical structure. In particular , the electronic nature of the substituent is considered as a key factor for the explanation of some observed optical limiting trends.

  2. Optics Express

    OpenAIRE

    Poon, Ting-Chung; Doh, K. B.

    2007-01-01

    The Hilbert transform as been investigated abundantly in coherent imaging. To the best of our knowledge, it is for the first time investigated in the context of incoherent imaging. We present a two-pupil optical heterodyne scanning system and analyze mathematically the design of its two pupils such that the optical system can perform the Hilbert transform on incoherent objects. Computer simulations of the idea clarify the theoretical results. (c) 2007 Optical Society of America.

  3. Optical electronics

    CERN Document Server

    Yariv, Amnon

    1991-01-01

    This classic text introduces engineering students to the first principles of major phenomena and devices of optoelectronics and optical communication technology. Yariv's "first principles" approach employs real-life examples and extensive problems. The text includes separate chapters on quantum well and semiconductor lasers, as well as phase conjugation and its applications. Optical fiber amplification, signal and noise considerations in optical fiber systems, laser arrays and distributed feedback lasers all are covered extensively in major sections within chapters.

  4. Optical based tactile shear and normal load sensor

    Energy Technology Data Exchange (ETDEWEB)

    Salisbury, Curt Michael

    2015-06-09

    Various technologies described herein pertain to a tactile sensor that senses normal load and/or shear load. The tactile sensor includes a first layer and an optically transparent layer bonded together. At least a portion of the first layer is made of optically reflective material. The optically transparent layer is made of resilient material (e.g., clear silicone rubber). The tactile sensor includes light emitter/light detector pair(s), which respectively detect either normal load or shear load. Light emitter(s) emit light that traverses through the optically transparent layer and reflects off optically reflective material of the first layer, and light detector(s) detect and measure intensity of reflected light. When a normal load is applied, the optically transparent layer compresses, causing a change in reflected light intensity. When shear load is applied, a boundary between optically reflective material and optically absorptive material is laterally displaced, causing a change in reflected light intensity.

  5. Mechanism of optical unidirectional transmission in subwavelength dual-metal gratings

    Science.gov (United States)

    Gao, H.; Zheng, Z. Y.; Hao, H. Y.; Dong, A. G.; Fan, Z. J.; Liu, D. H.

    2014-03-01

    The mechanism of optical unidirectional (OUD) transmission in parallel subwavelength dual-metal gratings was investigated. It was found that this kind of OUD phenomenon originates from the coupling of the surface plasmon polaritons (SPPs) between the front grating and a layer of metal film which replaces the rear grating. The higher the intensity of the coupled SPPs at the entrances of the rear grating, the higher the transmittance can be achieved. Basing on this property, an effective OUD example was achieved by exploring the intensity difference at the entrances of the rear gratings between the two incidences of opposite directions. In this kind of OUD, the positive transmittance can exceed 80 % and the difference between the transmittances of the two opposite directions can be as large as 63 %. The detailed design process was also presented.

  6. Transient photoconductivity and femtosecond nonlinear optical properties of a conjugated polymer-graphene oxide composite

    Energy Technology Data Exchange (ETDEWEB)

    Nalla, Venkatram; Ji Wei [Department of Physics, National University of Singapore, Singapore 117542 (Singapore); Polavarapu, Lakshminarayana; Manga, Kiran Kumar; Goh, Bee Min; Loh, Kian Ping; Xu Qinghua, E-mail: chmxqh@nus.edu.sg, E-mail: phyjiwei@nus.edu.sg [Department of Chemistry, National University of Singapore, Singapore 117543 (Singapore)

    2010-10-15

    A water soluble conjugated thiophene polymer, sodium salt of poly[2-(3-thienyl)ethoxy-4-butylsulfonate] (TPP), and graphene oxide (GO) composite film (GO-TPP) device was prepared. Transient photoconductivity measurements were carried out on the GO-TPP composite film using 150 ns laser pulses of 527 nm wavelength. Highly efficient photocurrent generation was observed from the GO-TPP film. The relationships of the film photoconductivity, photocurrent decay time and electron decay times with the incident light intensity were investigated. The photoconductive gain of the film was determined to be greater than 40% and to be independent of the light intensity. Furthermore, the femtosecond nonlinear optical properties of the GO-TPP film were measured using 800 nm femtosecond laser pulses and the composite film exhibited high nonlinear absorption and nonlinear refraction coefficients.

  7. Dysphonia in preterm children: assessing incidence and response to treatment.

    Science.gov (United States)

    Reynolds, Victoria; Meldrum, Suzanne; Simmer, Karen; Vijayasekaran, Shyan; French, Noel P

    2014-03-01

    Mild dysphonia in childhood is surprisingly common, yet moderate to severe dysphonia is rare. The latter has been associated with complex medical conditions and congenital abnormalities. Intubation injury has also been documented as a cause of childhood dysphonia. Children born very preterm may be intubated as part of the intensive care administered in the perinatal and neonatal periods, yet there are few studies investigating dysphonia in this population. This study will be the first to: use an objective acoustic voice assessment in a paediatric study, document the incidence of dysphonia in very preterm children at school age, and conduct a controlled trial of behavioural voice therapy in this population. This study will consist of three phases: assessment of voice quality and its impact on quality of life in up to 200 children born at less than 32 weeks' gestation: assessment of the nature and extent of laryngeal pathology in children with moderate to severe dysphonia; and a non-blinded, randomised controlled trial of behavioural voice therapy in children with moderate to severe dysphonia. This study will be the first to use clinical assessment to examine the voice quality of very preterm children, and to use fibre optic endoscopic evaluation of laryngeal function to determine the nature and extent of any laryngeal pathology in such children. Those participants with significant voice difficulties will be randomised to receive treatment immediately or after the eight week assessment. This study is registered on the Australian New Zealand Clinical Trials Registry (ACTRN12613001015730/ACTRN12613001012763). Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  8. Optic nerve hypoplasia

    Directory of Open Access Journals (Sweden)

    Savleen Kaur

    2013-01-01

    Full Text Available Optic nerve hypoplasia (ONH is a congenital anomaly of the optic disc that might result in moderate to severe vision loss in children. With a vast number of cases now being reported, the rarity of ONH is obviously now refuted. The major aspects of ophthalmic evaluation of an infant with possible ONH are visual assessment, fundus examination, and visual electrophysiology. Characteristically, the disc is small, there is a peripapillary double-ring sign, vascular tortuosity, and thinning of the nerve fiber layer. A patient with ONH should be assessed for presence of neurologic, radiologic, and endocrine associations. There may be maternal associations like premature births, fetal alcohol syndrome, maternal diabetes. Systemic associations in the child include endocrine abnormalities, developmental delay, cerebral palsy, and seizures. Besides the hypoplastic optic nerve and chiasm, neuroimaging shows abnormalities in ventricles or white- or gray-matter development, septo-optic dysplasia, hydrocephalus, and corpus callosum abnormalities. There is a greater incidence of clinical neurologic abnormalities in patients with bilateral ONH (65% than patients with unilateral ONH. We present a review on the available literature on the same to urge caution in our clinical practice when dealing with patients with ONH. Fundus photography, ocular coherence tomography, visual field testing, color vision evaluation, neuroimaging, endocrinology consultation with or without genetic testing are helpful in the diagnosis and management of ONH. (Method of search: MEDLINE, PUBMED.

  9. Relationship between nursing workloads and patient safety incidents.

    Science.gov (United States)

    Nishizaki, Yuji; Tokuda, Yasuharu; Sato, Ekiko; Kato, Keiko; Matsumoto, Akiko; Takekata, Miwako; Terai, Mineko; Watanabe, Chitose; Lim, Yang Ya; Ohde, Sachiko; Ishikawa, Ryoichi

    2010-05-26

    To evaluate the relationship between nursing workloads and patient safety incidents in inpatient wards of a general hospital. A retrospective data analysis was conducted involving the internal medicine wards in a teaching hospital in Japan between July 1st and December 31st, 2006. To assess associations between nursing workloads and patient safety incidents, we analyzed the following: the relationships between the level of patients' dependency and the number of incident reports; and the relationships between the presence of accidental falls and the presence of patients transferred from the intensive care unit to the wards. Fifty-five nurses worked on the wards (105 beds). The total number of incidents was 142 over the 184 days of this study. There was a positive trend between the number of incidents and the total patient dependency score. The presence of accidental falls in the wards was associated with the presence of transfers from the intensive care unit to the wards (odds ratio 3.14, 95% confidence interval: 1.48, 6.65). Greater nursing workloads may be related to the higher number of patient safety incidents in inpatient wards of hospitals.

  10. Electrifying photonic metamaterials for tunable nonlinear optics.

    Science.gov (United States)

    Kang, Lei; Cui, Yonghao; Lan, Shoufeng; Rodrigues, Sean P; Brongersma, Mark L; Cai, Wenshan

    2014-08-11

    Metamaterials have not only enabled unprecedented flexibility in producing unconventional optical properties that are not found in nature, they have also provided exciting potential to create customized nonlinear media with high-order properties correlated to linear behaviour. Two particularly compelling directions are active metamaterials, whose optical properties can be purposely tailored by external stimuli in a reversible manner, and nonlinear metamaterials, which enable intensity-dependent frequency conversion of light waves. Here, by exploring the interaction of these two directions, we leverage the electrical and optical functions simultaneously supported in nanostructured metals and demonstrate electrically controlled nonlinear optical processes from a metamaterial. Both second harmonic generation and optical rectification, enhanced by the resonance behaviour in the metamaterial absorber, are modulated externally with applied voltage signals. Our results reveal an opportunity to exploit optical metamaterials as self-contained, dynamic electro-optic systems with intrinsically embedded electrical functions and optical nonlinearities.

  11. Investigating Optical Properties of One-Dimensional Photonic Crystals Containing Semiconductor Quantum Wells

    Directory of Open Access Journals (Sweden)

    Mahshid Mokhtarnejad

    2017-01-01

    Full Text Available This study examined MQWs made of InGaAs/GaAs, InAlAs/InP, and InGaAs/InP in terms of their band structure and reflectivity. We also demonstrated that the reflectivity of MQWs under normal incident was at maximum, while both using a strong pump and changing incident angle reduced it. Reflectivity of the structure for a weak probe pulse depends on polarization, intensity of the pump pulse, and delay between the probe pulse and the pump pulse. So this system can be used as an ultrafast all-optical switch which is inspected by the transfer matrix method. After studying the band structure of the one-dimensional photonic crystal, the optical stark effect (OSE was considered on it. Due to the OSE on virtual exciton levels, the switching time can be in the order of picoseconds. Moreover, it is demonstrated that, by introducing errors in width of barrier and well as well as by inserting defect, the reflectivity is reduced. Thus, by employing the mechanism of stark effect MQWs band-gaps can be easily controlled which is useful in designing MWQ based optical switches and filters. By comparing the results, we observe that the reflectivity of MWQ containing 200 periods of InAlAs/InP quantum wells shows the maximum reflectivity of 96%.

  12. Patient Safety Incidents and Nursing Workload

    Directory of Open Access Journals (Sweden)

    Katya Cuadros Carlesi

    Full Text Available ABSTRACT Objective: to identify the relationship between the workload of the nursing team and the occurrence of patient safety incidents linked to nursing care in a public hospital in Chile. Method: quantitative, analytical, cross-sectional research through review of medical records. The estimation of workload in Intensive Care Units (ICUs was performed using the Therapeutic Interventions Scoring System (TISS-28 and for the other services, we used the nurse/patient and nursing assistant/patient ratios. Descriptive univariate and multivariate analysis were performed. For the multivariate analysis we used principal component analysis and Pearson correlation. Results: 879 post-discharge clinical records and the workload of 85 nurses and 157 nursing assistants were analyzed. The overall incident rate was 71.1%. It was found a high positive correlation between variables workload (r = 0.9611 to r = 0.9919 and rate of falls (r = 0.8770. The medication error rates, mechanical containment incidents and self-removal of invasive devices were not correlated with the workload. Conclusions: the workload was high in all units except the intermediate care unit. Only the rate of falls was associated with the workload.

  13. Progress in Ultrafast Intense Laser Science

    CERN Document Server

    Yamanouchi, Kaoru; Li, Ruxin; Chin, See Leang

    2009-01-01

    The PUILS series presents Progress in Ultrafast Intense Laser Science, a newly emerging interdisciplinary research field spanning atomic and molecular physics, molecular science, and optical science. PUILS has been stimulated by the recent development of ultrafast laser technologies. Each volume contains approximately 15 chapters, authored by researchers at the forefront. Each chapter opens with an overview of the topics to be discussed, so that researchers, who are not experts in the specific topics, as well as graduate students can grasp the importance and attractions of this sub-field of research, and these are followed by reports of cutting-edge discoveries. This fourth volume covers a broad range of topics from this interdisciplinary research field, focusing on strong field ionization of atoms; excitation, ionization and fragmentation of molecules; nonlinear intense optical phenomena and attosecond pulses; and laser - solid interactions and photoemission.

  14. Polarization Optics

    OpenAIRE

    Fressengeas, Nicolas

    2010-01-01

    The physics of polarization optics *Polarized light propagation *Partially polarized light; DEA; After a brief introduction to polarization optics, this lecture reviews the basic formalisms for dealing with it: Jones Calculus for totally polarized light and Stokes parameters associated to Mueller Calculus for partially polarized light.

  15. Optical Computing

    Indian Academy of Sciences (India)

    Integration (VLSI) technology with smaller device dimensions and greater complexity. The smallest .... on a chip, much less than what was mentioned earlier (optical integration is still in its infancy compared to electronics). ..... Optical tunnel devices are under continuous development varying from small caliber endoscopes to ...

  16. Optical Computing

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 8; Issue 6. Optical Computing - Optical Components and Storage Systems. Debabrata Goswami. General Article Volume 8 Issue 6 June 2003 pp 56-71. Fulltext. Click here to view fulltext PDF. Permanent link:

  17. Statistics of spatially integrated speckle intensity difference

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Yura, Harold

    2009-01-01

    We consider the statistics of the spatially integrated speckle intensity difference obtained from two separated finite collecting apertures. For fully developed speckle, closed-form analytic solutions for both the probability density function and the cumulative distribution function are derived h...... here for both arbitrary values of the mean number of speckles contained within an aperture and the degree of coherence of the optical field. Additionally, closed-form expressions are obtained for the corresponding nth statistical moments....

  18. Trends in stroke incidence. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Truelsen, T; Prescott, E; Grønbaek, M

    1997-01-01

    in men, whose annual rate ratio was 0.97 (95% CI, 0.95 to 0.99), but not in women, whose annual rate ratio was 0.98 (95% CI, 0.95 to 1.00). Throughout four observed periods the stroke incidence among men remained significantly higher than that for women. CONCLUSIONS: During the period from 1976 to 1993......BACKGROUND AND PURPOSE: Stroke incidence has increased in some countries and decreased in others. After 20 years of intensive antihypertensive treatment the latter could be expected, and we have evaluated the sex-specific temporal trends in stroke incidence using 17 years of follow...... at least one of the two first examinations as well as the total cohort including nonresponders. Subjects between 45 and 84 years of age were followed from March 1, 1976 until March 1, 1993. Changes in age-specific stroke incidence were calculated by means of Poisson regression analysis. RESULTS...

  19. Optical biosensors.

    Science.gov (United States)

    Damborský, Pavel; Švitel, Juraj; Katrlík, Jaroslav

    2016-06-30

    Optical biosensors represent the most common type of biosensor. Here we provide a brief classification, a description of underlying principles of operation and their bioanalytical applications. The main focus is placed on the most widely used optical biosensors which are surface plasmon resonance (SPR)-based biosensors including SPR imaging and localized SPR. In addition, other optical biosensor systems are described, such as evanescent wave fluorescence and bioluminescent optical fibre biosensors, as well as interferometric, ellipsometric and reflectometric interference spectroscopy and surface-enhanced Raman scattering biosensors. The optical biosensors discussed here allow the sensitive and selective detection of a wide range of analytes including viruses, toxins, drugs, antibodies, tumour biomarkers and tumour cells. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  20. Incident IR Bandwidth Effects on Efficiency and Shaping for Third Harmonic Generation of Quasi-Rectangular UV Longitudinal Profiles

    International Nuclear Information System (INIS)

    2010-01-01

    ir longitudinal profile is quasi-rectangular (i.e. nonzero risetime and falltime with small intensity variation on the plateau) with a 10 psec pulse duration (FWHM). By assumption, this profile has been established upstream of the crystals at the fundamental ir wavelength. The simplest possible optical configuration is used in this work as shown in figure 1. The first crystal is the site of second harmonic generation (SHG) driven by the incident ir irradiation of central wavelength, 800nm. Downstream of the first crystal, the second crystal is the site of third harmonic generation (THG) which occurs by sum frequency mixing. Inter-crystal optics (such as a half waveplate) are assumed to be lossless at the fundamental and second harmonic wavelengths. As shown in figure 1, a portion of the incident ir irradiation is not sequestered from the first crystal for subsequent THG in the second crystal. Also, quasi-phase matching configurations and other complex compensation schemes have not been investigated at this point. The simplistic geometry better elucidates the intrinsic acceptance bandwidth limitations imposed by the crystals. Our goal in this endeavor has been to conduct a quantitative assessment of incident ir bandwidth effects on the THG process for BBO material of varied thicknesses and not, at this stage, to comply with all uv pulse specifications for the LCLS RF Photoinjector. Nonetheless, our results can be compared with LCLS photoinjector uv pulse requirements which call for a nominal 10 psec FWHM with 1 psec risetime and falltime and a nominally flat plateau (allowing for slope adjustments) with no more than a 5% rms proportional intensity variation. Furthermore, the results of this work can be used to suggest crystal thicknesses that would likely comply with all uv pulse requirements given the appropriate longitudinal profile and bandwidth for an input ir pulse.

  1. Analysis of laser-induced heating in optical neuronal guidance

    DEFF Research Database (Denmark)

    Ebbesen, Christian L.; Bruus, Henrik

    2012-01-01

    Recently, it has been shown that it is possible to control the growth direction of neuronal growth cones by stimulation with weak laser light; an effect dubbed optical neuronal guidance. The effect exists for a broad range of laser wavelengths, spot sizes, spot intensities, optical intensity...

  2. Goiania incident case study

    International Nuclear Information System (INIS)

    Petterson, J.S.

    1988-06-01

    The reasons for wanting to document this case study and present the findings are simple. According to USDOE technical risk assessments (and our own initial work on the Hanford socioeconomic study), the likelihood of a major accident involving exposure to radioactive materials in the process of site characterization, construction, operation, and closure of a high-level waste repository is extremely remote. Most would agree, however, that there is a relatively high probability that a minor accident involving radiological contamination will occur sometime during the lifetime of the repository -- for example, during transport, at an MRS site or at the permanent site itself during repacking and deposition. Thus, one of the major concerns of the Yucca Mountain Socioeconomic Study is the potential impact of a relatively minor radiation-related accident. A large number of potential impact of a relatively minor radiation-related accident. A large number of potential accident scenarios have been under consideration (such as a transportation or other surface accident which results in a significant decline in tourism, the number of conventions, or the selection of Nevada as a retirement residence). The results of the work in Goiania make it clear, however, that such a significant shift in established social patterns and trends is not likely to occur as a direct outcome of a single nuclear-related accident (even, perhaps, a relatively major one), but rather, are likely to occur as a result of the enduring social interpretations of such an accident -- that is, as a result of the process of understanding, communicating, and socially sustaining a particular set of associations with respect to the initial incident

  3. [Hospital infections in neonatal intensive care units].

    Science.gov (United States)

    Durisić, Jasna; Marković-Denić, Ljiljana; Ilić, Slobodanka; Ramadani, Ruzdi

    2005-01-01

    Sick newborn babies in the neonatal intensive care units (NICU) are at increased risk for hospital-acquired infections (HI). The aim of our study was to determine the incidence and localization of neonatal hospital infections in NICU. A prospective, six-month study was carried out in a NICU. All patients hospitalized in NICU longer then 48 hours were examined according to their basic descriptive-epidemiological characteristics and the incidence of all hospital-acquired infections (diagnosed using CDC criteria) were accounted for. The incidence of patients with HI was 46.1% while the incidence of HI was 57.2%. On the basis of patients' records in the NICU, the incidence of HI was 43.9 per 1000 patient-hospital days. Patients with HI were hospitalized significantly longer in NICU than patients without HI (t=9.2 DF=267 p<0.001). In terms of localization of HI, a large number of patients had pneumonia--74.7% (115/154), followed by sepsis (37/154), while two had meningitis. This study suggests that it is necessary to maintain continuous surveillance of HI in NICU, as well as infection control measures, which are also very beneficial.

  4. Intense microfocus X-ray source

    International Nuclear Information System (INIS)

    Parish, R.W.

    1984-01-01

    An intense microfocus X-ray source comprises a chamber, a turbomolecular pump to evacuate the chamber, an anode and a cathode within the chamber and electromagnet coils to focus electrons from the cathode on to a small spot on the anode to produce a divergent X-ray beam. The pump has a shaft to which the anode is connected, so that operation of the pump causes rotation of the anode. Heat generated in the anode by the incident electron beam is spread over a larger area than if the anode were stationary. Consequently a more intense electron beam can be used, leading to a more intense X-ray beam, without melting the anode. (author)

  5. All-optical label and payload separator for a time-serial RZ-IM/IM scheme

    DEFF Research Database (Denmark)

    Vegas Olmos, Juan José; Tafur Monroy, Idelfonso; Koonen, A.M.J.

    2006-01-01

    We demonstrate an all-optical label and payload separator based on nonlinear optical signal processing with a semiconductor optical amplifier. The separator handles return-to-zero intensity modulated packets with high bandwidth efficiency utilization.......We demonstrate an all-optical label and payload separator based on nonlinear optical signal processing with a semiconductor optical amplifier. The separator handles return-to-zero intensity modulated packets with high bandwidth efficiency utilization....

  6. Geometric Phase Generated Optical Illusion.

    Science.gov (United States)

    Yue, Fuyong; Zang, Xiaofei; Wen, Dandan; Li, Zile; Zhang, Chunmei; Liu, Huigang; Gerardot, Brian D; Wang, Wei; Zheng, Guoxing; Chen, Xianzhong

    2017-09-12

    An optical illusion, such as "Rubin's vase", is caused by the information gathered by the eye, which is processed in the brain to give a perception that does not tally with a physical measurement of the stimulus source. Metasurfaces are metamaterials of reduced dimensionality which have opened up new avenues for flat optics. The recent advancement in spin-controlled metasurface holograms has attracted considerate attention, providing a new method to realize optical illusions. We propose and experimentally demonstrate a metasurface device to generate an optical illusion. The metasurface device is designed to display two asymmetrically distributed off-axis images of "Rubin faces" with high fidelity, high efficiency and broadband operation that are interchangeable by controlling the helicity of the incident light. Upon the illumination of a linearly polarized light beam, the optical illusion of a 'vase' is perceived. Our result provides an intuitive demonstration of the figure-ground distinction that our brains make during the visual perception. The alliance between geometric metasurface and the optical illusion opens a pathway for new applications related to encryption, optical patterning, and information processing.

  7. A Design Report for the Optical Transition Radiation Imager for the LCLS Undulator

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Bingxin

    2010-12-13

    The Linac Coherent Light Source (LCLS), a free-electron x-ray laser, is under design and construction. Its high-intensity electron beam, 3400 A in peak current and 46 TW in peak power, is concentrated in a small area (37 micrometer in rms radius) inside its undulator. Ten optical transition radiation (OTR) imagers are planned between the undulator segments for characterizing the transverse profiles of the electron beam. In this note, we report on the optical and mechanical design of the OTR imager. Through a unique optical arrangement, using a near-normal-incidence screen and a multi-layer coated mirror, this imager will achieve a fine resolution (12 micrometer or better) over the entire field of view (8 mm x 5 mm), with a high efficiency for single-shot imaging. A digital camera will be used to read out the beam images in a programmable region (5 mm x 0.5 mm) at the full beam repetition rate (120 Hz), or over the entire field at a lower rate (10 Hz). Its built-in programmable amplifier will be used as an electronic intensity control.

  8. Thermoluminescent and optical processes in alkaline halogenides dosemeters contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.; Melendrez, R.; Castaneda, B.; Pedroza M, M.; Chernov, V.; Perez S, R.; Aceves, R.

    2000-01-01

    Recent research results are presented about the properties of the optical processes of photo transferred thermoluminescence (TLFT), optical whitening (BO), thermoluminescence induced by light (TLL) and its effect in the thermoluminescent curve (Tl) produced by ionizing and non-ionizing radiation. The systematic analysis of all these processes, acquires a singular importance due that actually the alkaline halogenide crystals are object of intense investigations which analyse their potential applications as detectors and radiation dosemeters through stimulated optical luminescence techniques or thermoluminescence. The obtained data show that the Tl curve of material with this nature can be enormously affected by exposure of phosphorus to the environmental light or UV. This is in part due to liberation processes of charge bearers are shouted and makes a subsequent trapping in less temperature traps; at the same time that induce changes in the intensity of determined Tl bands. Additionally, also it is observed that mentioned phenomena are related as with wavelength of incident light as of the illumination time. Finally, the obtained information allows to conclude that although the illumination effect is extremely complex, it is associated and can be explained mainly with phenomena that implicate the electrons excitation trapped in form of F centers and trapping mechanisms or radioactive and non-radioactive recombination. (Author)

  9. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... or vigorous-intensity based upon the amount of energy used by the body while doing the activity. Top of Page Moderate Intensity Walking briskly (3 miles per hour or faster, but not race-walking) Water aerobics Bicycling slower than 10 miles per hour ...

  10. Rigorous modelling of light's intensity angular-profile in Abbe refractometers with absorbing homogeneous fluids

    International Nuclear Information System (INIS)

    García-Valenzuela, A; Contreras-Tello, H; Márquez-Islas, R; Sánchez-Pérez, C

    2013-01-01

    We derive an optical model for the light intensity distribution around the critical angle in a standard Abbe refractometer when used on absorbing homogenous fluids. The model is developed using rigorous electromagnetic optics. The obtained formula is very simple and can be used suitably in the analysis and design of optical sensors relying on Abbe type refractometry.

  11. Light Penetration and Light-Intensity in Sandy Marine-Sediments Measured with Irradiance and Scalar Irradiance Fiberoptic Microprobes Rid A-1977-2009

    DEFF Research Database (Denmark)

    KUHL, M.; LASSEN, C.; JØRGENSEN, BB

    1994-01-01

    with increasing particle size, and infrared light penetrated deeper than visible light in all sediments. Attenuation spectra of scalar irradiance exhibited the strongest attenuation at 450 to 500 ran, and a continuous decrease in attenuation coefficent towards the longer wavelengths was observed. Measurements......Fiber-optic microprobes for determining irradiance and scalar irradiance were used for light measurements in sandy sediments of different particle size. Intense scattering caused a maximum integral light intensity [photon scalar irradiance, E0(400 to 700 rim) and E0(700 to 880 nm)] at the sediment...... surface ranging from 180 % of incident collimated light in the coarsest sediment (250 to 500 mum grain size) up to 280 % in the finest sediment ( 1 mm in the coarsest sediments. Below 1 mm, light was attenuated exponentially with depth in all sediments. Light attenuation coefficients decreased...

  12. Hanle Detection for Optical Clocks

    Directory of Open Access Journals (Sweden)

    Xiaogang Zhang

    2015-01-01

    Full Text Available Considering the strong inhomogeneous spatial polarization and intensity distribution of spontaneous decay fluorescence due to the Hanle effect, we propose and demonstrate a universe Hanle detection configuration of electron-shelving method for optical clocks. Experimental results from Ca atomic beam optical frequency standard with electron-shelving method show that a designed Hanle detection geometry with optimized magnetic field direction, detection laser beam propagation and polarization direction, and detector position can improve the fluorescence collection rate by more than one order of magnitude comparing with that of inefficient geometry. With the fixed 423 nm fluorescence, the improved 657 nm optical frequency standard signal intensity is presented. The potential application of the Hanle detection geometry designed for facilitating the fluorescence collection for optical lattice clock with a limited solid angle of the fluorescence collection has been discussed. The Hanle detection geometry is also effective for ion detection in ion optical clock and quantum information experiments. Besides, a cylinder fluorescence collection structure is designed to increase the solid angle of the fluorescence collection in Ca atomic beam optical frequency standard.

  13. Fiber optic coupled optical sensor

    Science.gov (United States)

    Fleming, Kevin J.

    2001-01-01

    A displacement sensor includes a first optical fiber for radiating light to a target, and a second optical fiber for receiving light from the target. The end of the first fiber is adjacent and not axially aligned with the second fiber end. A lens focuses light from the first fiber onto the target and light from the target onto the second fiber.

  14. Real time freeway incident detection.

    Science.gov (United States)

    2014-04-01

    The US Department of Transportation (US-DOT) estimates that over half of all congestion : events are caused by highway incidents rather than by rush-hour traffic in big cities. Real-time : incident detection on freeways is an important part of any mo...

  15. The Incidence of Posttraumatic Stress Disorder After Floods: A Meta-Analysis.

    Science.gov (United States)

    Chen, Long; Liu, Aizhong

    2015-06-01

    This study analyzes the incidence of posttraumatic stress disorder (PTSD) among flood victims, between different flood intensities, and between different time points after a flood. A search of several electronic literature databases was conducted to collect data on the incidence of PTSD after a flood. Loney criteria for research quality were used to evaluate the quality of selected search results. The combined incidence of PTSD was estimated using the Freeman-Tukey double arcsine transformation method. Subgroup analyses were conducted on different trauma intensities and different time points after a flood. Sensitivity analysis was performed to evaluate the impact of research quality. Fourteen articles were included in this meta-analysis, including a total of 40 600 flood victims; 3862 victims were diagnosed with PTSD. The combined incidence of PTSD was 15.74%. The subgroup analyses showed that the incidence of PTSD in victims who experienced severe and moderate flood intensity was higher than that in victims who experienced mild flood intensity. The incidence of PTSD was lower at 6 or more months after a flood (11.45%) than within 6 months (16.01%) of a flood. In conclusion, the incidence of PTSD among floods of different trauma intensities was statistically significant.

  16. Nonlinear optics

    CERN Document Server

    Bloembergen, Nicolaas

    1996-01-01

    Nicolaas Bloembergen, recipient of the Nobel Prize for Physics (1981), wrote Nonlinear Optics in 1964, when the field of nonlinear optics was only three years old. The available literature has since grown by at least three orders of magnitude.The vitality of Nonlinear Optics is evident from the still-growing number of scientists and engineers engaged in the study of new nonlinear phenomena and in the development of new nonlinear devices in the field of opto-electronics. This monograph should be helpful in providing a historical introduction and a general background of basic ideas both for expe

  17. Hispanic Inpatient Pain Intensity.

    Science.gov (United States)

    McDonald, Deborah Dillon; Ambrose, Margaret; Morey, Barbara

    2015-11-01

    Hispanic adults experience significant pain, but little is known about their pain during hospitalization. The purpose of this research was to describe Hispanic inpatients' pain intensity and compare their pain intensity with that of non-Hispanic patients. A post hoc descriptive design was used to examine 1,466 Hispanic inpatients' medical records (63.2% English speakers) and 12,977 non-Hispanic inpatients' medical records from one hospital for 2012. Mean documented pain intensity was mild for both Hispanic and non-Hispanic inpatients. Pain intensity was greater for English-speaking Hispanic patients than Spanish speakers. The odds of being documented with moderate or greater pain intensity decreased 30% for Spanish-speaking patients. Greater pain intensity documented for English-speaking Hispanic inpatients suggests underreporting of pain intensity by Spanish-speaking patients. Practitioners should use interpreter services when assessing and treating pain with patients who speak languages different from the practitioners' language(s). © The Author(s) 2014.

  18. Low-SNR Capacity of Parallel IM-DD Optical Wireless Channels

    KAUST Repository

    Chaaban, Anas

    2016-11-29

    The capacity of parallel intensity-modulation and direct-detection (IM-DD) optical wireless channels with total average intensity and per-channel peak intensity constraints is studied. The optimal intensity allocation at low signal-to-noise ratio (SNR) is derived, leading to the capacity-achieving onoff keying (OOK) distribution. Interestingly, while activating the strongest channel is optimal if (i) the peak intensity is fixed, this is not the case if (ii) the peak intensity is proportional to the average intensity. The minimum average optical intensity per bit is also studied, and is characterized for case (i) where it is achievable at low SNR. However, in case (ii), the average optical intensity per bit grows indefinitely as SNR decreases, indicating that lower optical intensity per bit can be achieved at moderate SNR than at low SNR.

  19. Focusing of Intense Laser via Parabolic Plasma Concave Surface

    Science.gov (United States)

    Zhou, Weimin; Gu, Yuqiu; Wu, Fengjuan; Zhang, Zhimeng; Shan, Lianqiang; Cao, Leifeng; Zhang, Baohan

    2015-12-01

    Since laser intensity plays an important role in laser plasma interactions, a method of increasing laser intensity - focusing of an intense laser via a parabolic plasma concave surface - is proposed and investigated by three-dimensional particle-in-cell simulations. The geometric focusing via a parabolic concave surface and the temporal compression of high harmonics increased the peak intensity of the laser pulse by about two orders of magnitude. Compared with the improvement via laser optics approaches, this scheme is much more economic and appropriate for most femtosecond laser facilities. supported by National Natural Science Foundation of China (Nos. 11174259, 11175165), and the Dual Hundred Foundation of China Academy of Engineering Physics

  20. Integrated optics

    International Nuclear Information System (INIS)

    Jekowski, J.; Aeby, I.

    1979-01-01

    The purpose of the R and D effort is to establish a baseline technology in integrated optic techniques within the EMG. Significant investment presently being made by industry in this area indicates that this technology may offer an alternative solution for high speed digital data acquisition and transmission. The objectives of this year's integrated optics program were three-fold: (1) to establish a literature search and maintain industry contacts in an attempt to make the needs of the Weapons Test Program known; (2) to assist the Las Vegas Hybrid facility in establising integrated optic fabrication techniques for their new Thin Film Laboratory; and (3) to conduct basic experiments at Los Alamos in the construction of photolithograhicaly etched plastic film devices. The report describes the successful completion of preliminary investigations into photolithographic techniques and continuing investigations into newly announced integrated optic techniques and devices that would be applicable to the weapons test program