WorldWideScience

Sample records for incident directions detector

  1. Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

    International Nuclear Information System (INIS)

    Badano, Aldo; Freed, Melanie; Fang Yuan

    2011-01-01

    Purpose: The authors describe the modifications to a previously developed analytical model of indirect CsI:Tl-based detector response required for studying oblique x-ray incidence effects in direct semiconductor-based detectors. This first-order approximation analysis allows the authors to describe the associated degradation in resolution in direct detectors and compare the predictions to the published data for indirect detectors. Methods: The proposed model is based on a physics-based analytical description developed by Freed et al. [''A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems,'' Med. Phys. 37(6), 2593-2605 (2010)] that describes detector response functions for indirect detectors and oblique incident x rays. The model, modified in this work to address direct detector response, describes the dependence of the response with x-ray energy, thickness of the transducer layer, and the depth-dependent blur and collection efficiency. Results: The authors report the detector response functions for indirect and direct detector models for typical thicknesses utilized in clinical systems for full-field digital mammography (150 μm for indirect CsI:Tl and 200 μm for a-Se direct detectors). The results suggest that the oblique incidence effect in a semiconductor detector differs from that in indirect detectors in two ways: The direct detector model produces a sharper overall PRF compared to the response corresponding to the indirect detector model for normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction compared to that found in indirect detectors with respect to the response at normal incidence angles. Conclusions: Compared to the effect seen in indirect detectors, the direct detector model exhibits a sharper response at normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction with respect to the blur in the

  2. Developments of directional detectors with NaI(Tl)/BGO scintillators

    International Nuclear Information System (INIS)

    Shirakawa, Y.

    2004-01-01

    This paper describes directional gamma ray detectors with different types of scintillators. The detectors, which positively increase directional sensitivity to incident gamma rays, have been developed to measure directions, energies and counts of gamma rays, and to search for radioactive materials such as orphan radioisotopes or contaminations. Experimental results have shown that proposed directional detectors have a potential for practical use in real fields and will contribute to radiation protection and safety

  3. Dependence on incident angle of solid state detector response to gamma-rays

    International Nuclear Information System (INIS)

    Yamanishi, Hirokuni; Yamaguchi, Satarou; Yamaguchi, Takayuki; Ueki, Kohtaro

    2002-01-01

    The shape and size of a NaI(Tl) scintillator that should maximize response variation with γ-ray incident angle was estimated by analytical model calculation. It proved that, even for gamma rays of energy exceeding 1 MeV, a slab detector measuring 50 cm x 50 cm x 5 cm thick should present a ratio of at least 4 between maximum and minimum responses against incidence at different angles. For a sample case of 60 keV gamma rays, estimation of the incident angle dependence by means of Monte Carlo simulation agreed well with experiment using a CZT detector. The counts from photo-electric peak varied with incident angle roughly along a sine curve. The foregoing finding served as basis for proposing a practical direction finder for γ-ray source operating on the principle of determining the source direction from variations in count with incident angle. (author)

  4. Interferometric direction finding with a metamaterial detector

    Energy Technology Data Exchange (ETDEWEB)

    Venkatesh, Suresh; Schurig, David, E-mail: david.schurig@utah.edu [Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112 (United States); Shrekenhamer, David; Padilla, Willie [Department of Physics, Boston College, Chestnut Hill, Massachusetts 02467 (United States); Xu, Wangren; Sonkusale, Sameer [Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155 (United States)

    2013-12-16

    We present measurements and analysis demonstrating useful direction finding of sources in the S band (2–4 GHz) using a metamaterial detector. An augmented metamaterial absorber that supports magnitude and phase measurement of the incident electric field, within each unit cell, is described. The metamaterial is implemented in a commercial printed circuit board process with off-board back-end electronics. We also discuss on-board back-end implementation strategies. Direction finding performance is analyzed for the fabricated metamaterial detector using simulated data and the standard algorithm, MUtiple SIgnal Classification. The performance of this complete system is characterized by its angular resolution as a function of radiation density at the detector. Sources with power outputs typical of mobile communication devices can be resolved at kilometer distances with sub-degree resolution and high frame rates.

  5. Analysis of self-powered gamma ray detector with directional discrimination

    International Nuclear Information System (INIS)

    Levert, F.E.; Beyerlein, R.A.; Cox, S.A.

    1979-01-01

    The results of a combined Monte Carlo simulation and experimental investigation of the directional and energy dependent response of a self-powered gamma detector with a flat plate Pb-C central electrode are presented. The electron yield of the central electrode in a three dimensional mockup of the detector was calculated for photons of several discrete energies, emanating from an infinitely thin planar source, incident on the outer surface of the detector. Separate computations were done with the source facing the lead side and carbon side of the central electrode. Experimental measurements with a detector that closely matched the design used in the simulation were conducted in a graphite column next to a neutron leakage face of a low flux reactor. A localized gamma ray source was created by positioning a 235 U strip between the leakage face of the reactor and the detector. A comparison of results obtained in both cases showed good agreement. Also experimental measurements to determine the effect of the thickness of lead shielding surrounding the outer wall of the detector and space charge in the vacuum insulator between the central electrode and the inner wall on the response of the detector were performed. (Auth.)

  6. Measurement of the spatial resolution of wide-pitch silicon strip detectors with large incident angle

    International Nuclear Information System (INIS)

    Kawasaki, T.; Hazumi, M.; Nagashima, Y.

    1996-01-01

    As a part of R ampersand D for the BELLE experiment at KEK-B, we measured the spatial resolution of silicon strip detectors for particles with incident angles ranging from 0 degrees to 75 degrees. These detectors have strips with pitches of 50, 125 and 250 μm on the ohmic side. We have obtained the incident angle dependence which agreed well with a Monte Carlo simulation. The resolution was found to be 11 μm for normal incidence with a pitch of 50 μm, and 29 μm for incident angle of 75 degrees with a pitch of 250μm

  7. Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    McMullan, G., E-mail: gm2@mrc-lmb.cam.ac.uk [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH (United Kingdom); Faruqi, A.R. [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH (United Kingdom); Clare, D. [Crystallography and Institute of Structural and Molecular Biology, Birkbeck College, University of London, Malet Street, London WC1E 7HX (United Kingdom); Henderson, R. [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH (United Kingdom)

    2014-12-15

    Low dose electron imaging applications such as electron cryo-microscopy are now benefitting from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three detectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. - Highlights: • Three direct electron detectors offer better DQE than film at 300 keV. • Recorded 300 keV electron events on the detectors have very similar Landau distributions. • The Gatan K2 Summit detector has the highest DQE at low spatial frequency. • The FEI Falcon II detector has the highest DQE beyond one half the Nyquist frequency. • The Direct Electron DE-20 detector has the fastest data acquisition rate.

  8. Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

    International Nuclear Information System (INIS)

    McMullan, G.; Faruqi, A.R.; Clare, D.; Henderson, R.

    2014-01-01

    Low dose electron imaging applications such as electron cryo-microscopy are now benefitting from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three detectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. - Highlights: • Three direct electron detectors offer better DQE than film at 300 keV. • Recorded 300 keV electron events on the detectors have very similar Landau distributions. • The Gatan K2 Summit detector has the highest DQE at low spatial frequency. • The FEI Falcon II detector has the highest DQE beyond one half the Nyquist frequency. • The Direct Electron DE-20 detector has the fastest data acquisition rate

  9. Wavelength prediction of laser incident on amorphous silicon detector by neural network

    International Nuclear Information System (INIS)

    Esmaeili Sani, V.; Moussavi-Zarandi, A.; Kafaee, M.

    2011-01-01

    In this paper we present a method based on artificial neural networks (ANN) and the use of only one amorphous semiconductor detector to predict the wavelength of incident laser. Amorphous semiconductors and especially amorphous hydrogenated silicon, a-Si:H, are now widely used in many electronic devices, such as solar cells, many types of position sensitive detectors and X-ray imagers for medical applications. In order to study the electrical properties and detection characteristics of thin films of a-Si:H, n-i-p structures have been simulated by SILVACO software. The basic electronic properties of most of the materials used are known, but device modeling depends on a large number of parameters that are not all well known. In addition, the relationship between the shape of the induced anode current and the wavelength of the incident laser leads to complicated calculations. Soft data-based computational methods can model multidimensional non-linear processes and represent the complex input-output relation between the form of the output signal and the wavelength of incident laser.

  10. Wavelength prediction of laser incident on amorphous silicon detector by neural network

    Energy Technology Data Exchange (ETDEWEB)

    Esmaeili Sani, V., E-mail: vaheed_esmaeely80@yahoo.com [Amirkabir University of Technology, Faculty of Physics, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of); Moussavi-Zarandi, A.; Kafaee, M. [Amirkabir University of Technology, Faculty of Physics, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of)

    2011-10-21

    In this paper we present a method based on artificial neural networks (ANN) and the use of only one amorphous semiconductor detector to predict the wavelength of incident laser. Amorphous semiconductors and especially amorphous hydrogenated silicon, a-Si:H, are now widely used in many electronic devices, such as solar cells, many types of position sensitive detectors and X-ray imagers for medical applications. In order to study the electrical properties and detection characteristics of thin films of a-Si:H, n-i-p structures have been simulated by SILVACO software. The basic electronic properties of most of the materials used are known, but device modeling depends on a large number of parameters that are not all well known. In addition, the relationship between the shape of the induced anode current and the wavelength of the incident laser leads to complicated calculations. Soft data-based computational methods can model multidimensional non-linear processes and represent the complex input-output relation between the form of the output signal and the wavelength of incident laser.

  11. A direct electron detector for time-resolved MeV electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vecchione, T.; Denes, P.; Jobe, R. K.; Johnson, I. J.; Joseph, J. M.; Li, R. K.; Perazzo, A.; Shen, X.; Wang, X. J.; Weathersby, S. P.; Yang, J.; Zhang, D.

    2017-03-01

    The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μmμm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

  12. Incident-angle dependency found in track formation sensitivity of a plastic nuclear track detector (TD-1)

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    1999-01-01

    The present study was done since data are hardly available on the incident-angle dependency of track formation sensitivity (S) of the plastic nuclear track detector. Chips of a TD-1 plate, an antioxidant-doped CR-39 (diethyleglycol-bis-allylcarbonate, HARZLAS, Fukuvi Chem. Ind.), were used as a high-LET radiation detector and were exposed to heavy ion beams of C, Ne, and Si under different incident angles in Heavy Ion Medical Accelerator in Chiba of National Institute of Radiological Sciences. After exposed and etched, the chips were observed with an optical microscope and a program for image analysis to calculate S. The S values calculated were found smaller for the beams having lower incident angles. Thus the estimated LET values from the S-LET relationship for vertical incident beams showed large reduction for low-angle particles. Those potential errors should be quantified and corrected in determination of LET spectra in space. (K.H.)

  13. Direct intensity calibration of X-ray grazing-incidence microscopes with home-lab source

    Science.gov (United States)

    Li, Yaran; Xie, Qing; Chen, Zhiqiang; Xin, Qiuqi; Wang, Xin; Mu, Baozhong; Wang, Zhanshan; Liu, Shenye; Ding, Yongkun

    2018-01-01

    Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ˜95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ˜6.0%.

  14. Direct conversion Si and CdZnTe detectors for digital mammography

    CERN Document Server

    Yin Shi Shi; Maeding, D; Mainprize, J; Mawdsley, G; Yaffe, M J; Gordon, E E; Hamilton, W J

    2000-01-01

    Hybrid pixel detector arrays that convert X-rays directly into charge signals are under development at NOVA for application to digital mammography. This technology also has wide application possibilities in other fields of radiology or in industrial imaging, nondestructive evaluation (NDE) and nondestructive inspection (NDI). These detectors have potentially superior properties compared to either emulsion-based film-screen systems which has nonlinear response to X-rays, or phosphor-based detectors in which there is an intermediate step of X-ray to light photon conversion (Feig and Yaffe, Radiol. Clinics North America 33 (1995) 1205-1230). Potential advantages of direct conversion detectors are high quantum efficiencies (QE) of 98% or higher (for 0.3 mm thick CdZnTe detector with 20 keV X-rays), improved contrast, high sensitivity and low intrinsic noise. These factors are expected to contribute to high detective quantum efficiency (DQE). The prototype hybrid pixel detector developed has 50x50 mu m pixel size,...

  15. Direct digital conversion detector technology

    Science.gov (United States)

    Mandl, William J.; Fedors, Richard

    1995-06-01

    Future imaging sensors for the aerospace and commercial video markets will depend on low cost, high speed analog-to-digital (A/D) conversion to efficiently process optical detector signals. Current A/D methods place a heavy burden on system resources, increase noise, and limit the throughput. This paper describes a unique method for incorporating A/D conversion right on the focal plane array. This concept is based on Sigma-Delta sampling, and makes optimum use of the active detector real estate. Combined with modern digital signal processors, such devices will significantly increase data rates off the focal plane. Early conversion to digital format will also decrease the signal susceptibility to noise, lowering the communications bit error rate. Computer modeling of this concept is described, along with results from several simulation runs. A potential application for direct digital conversion is also reviewed. Future uses for this technology could range from scientific instruments to remote sensors, telecommunications gear, medical diagnostic tools, and consumer products.

  16. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  17. A direct reflection OLVF debris detector based on dark-field imaging

    Science.gov (United States)

    Li, Bo; Xi, Yinhu; Feng, Song; Mao, Junhong; Xie, You-Bai

    2018-06-01

    To solve the problems of monitoring wear debris in black oil, a direct reflection online visual ferrograph (OLVF) debris detector is presented. In current OLVF detectors, a reflected light source is used. The emitted light is reflected by wear debris directly instead of passing through the lube oil. Therefore, the transparency of the lube oil ceases to matter. Two experiments were conducted to validate the wear debris imaging feasibility and effectiveness of the newly developed detector. The results show that the visual feature information of the wear debris can be reliably obtained from black oil by this detector, and it can also be used to track the fast-changing wear of tribopairs at different wear stages. To the best of our knowledge, to date there is no other report for solving this issue.

  18. Nuclear Material Accountability Applications of a Continuous Energy and Direction Gamma Ray Detector

    International Nuclear Information System (INIS)

    Gerts, David; Bean, Robert; Paff, Marc

    2010-01-01

    The Idaho National Laboratory has recently developed a detector system based on the principle of a Wilson cloud chamber that gives the original energy and direction to a gamma ray source. This detector has the properties that the energy resolution is continuous and the direction to the source can be resolved to desired fidelity. Furthermore, the detector has low power requirements, is durable, operates in widely varying environments, and is relatively cheap to produce. This detector is expected, however, to require significant time to perform measurements. To mitigate the significant time for measurements, the detector is expected to scale to very large sizes with a linear increase in cost. For example, the proof of principle detector is approximately 30,000 cm3. This work describes the technical results that lead to these assertions. Finally, the applications of this detector are described in the context of nuclear material accountability.

  19. The case for a directional dark matter detector and the status of current experimental efforts

    CERN Document Server

    Ahlen, S; Battat, J B R; Billard, J; Bozorgnia, N; Burgos, S; Caldwell, T; Carmona, J M; Cebrián, S; Colas, P; Dafni, T; Daw, E; Dujmic, D; Dushkin, A; Fedus, W; Ferrer, E; Finkbeiner, D; Fisher, P H; Forbes, J; Fusayasu, T; Galan, J; Gamble, T; Ghag, C; Giomataris, Yu; Gold, M; Gomez, H; Gómez, M E; Gondolo, P; Green, A; Grignon, C; Guillaudin, O; Hagemann, C; Hattori, K; Henderson, S; Higashi, N; Ida, C; Iguaz, F J; Inglis, A; Irastorza, I G; Iwaki, S; Kaboth, A; Kabuki, S; Kadyk, J; Kallivayalil, N; Kubo, H; Kurosawa, S; Kudryavtsev, V A; Lamy, T; Lanza, R; Lawson, T B; Lee, A; Lee, E R; Lin, T; Loomba, D; López, J; Luzón, G; Manobu, T; Martoff, J; Mayet, F; McCluskey, B; Miller, E; Miuchi, K; Monroe, J; Morgan, B; Muna, D; Murphy, A St J; Naka, T; Nakamura, K; Nakamura, M; Nakano, T; Nicklin, G G; Nishimura, H; Niwa, K; Paling, S M; Parker, J; Petkov, A; Pipe, M; Pushkin, K; Robinson, M; Rodríguez, A; Rodríguez-Quintero, J; Sahin, T; Sanderson, R; Sanghi, N; Santos, D; Sato, O; Sawano, T; Sciolla, G; Sekiya, H; Slatyer, T R; Snowden-Ifft, D P; Spooner, N J C; Sugiyama, A; Takada, A; Takahashi, M; Takeda, A; Tanimori, T; Taniue, K; Tomas, A; Tomita, H; Tsuchiya, K; Turk, J; Tziaferi, E; Ueno, K; Vahsen, S; Vanderspek, R; Vergados, J; Villar, J A; Wellenstein, H; Wolfe, I; Yamamoto, R K; Yegoryan, H

    2010-01-01

    We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

  20. Directional Sensitivity in Light-Mass Dark Matter Searches with Single-Electron-Resolution Ionization Detectors

    Science.gov (United States)

    Kadribasic, Fedja; Mirabolfathi, Nader; Nordlund, Kai; Sand, Andrea E.; Holmström, Eero; Djurabekova, Flyura

    2018-03-01

    We propose a method using solid state detectors with directional sensitivity to dark matter interactions to detect low-mass weakly interacting massive particles (WIMPs) originating from galactic sources. In spite of a large body of literature for high-mass WIMP detectors with directional sensitivity, no available technique exists to cover WIMPs in the mass range semiconductor detectors allow for directional sensitivity once properly calibrated. We examine the commonly used semiconductor material response to these low-mass WIMP interactions.

  1. Design and Construction of Prototype Dark Matter Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Peter Fisher

    2012-03-23

    The Lepton Quark Studies (LQS) group is engaged in searching for dark matter using the Dark Matter Time Projection Chamber (DMTPC) at the Waste Isolation Pilot Plant (WIPP) (Carlsbad, NM). DMTPC is a direction-sensitive dark matter detector designed to measure the recoil direction and energy deposited by fluorine nuclei recoiling from the interaction with incident WIMPs. In the past year, the major areas of progress have been: to publish the first dark matter search results from a surface run of the DMTPC prototype detector, to build and install the 10L prototype in the underground laboratory at WIPP which will house the 1 m{sup 3} detector, and to demonstrate charge and PMT readout of the TPC using prototype detectors, which allow triggering and {Delta}z measurement to be used in the 1 m{sup 3} detector under development.

  2. Performance of silicon pixel detectors at small track incidence angles for the ATLAS Inner Tracker upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Viel, Simon, E-mail: sviel@lbl.gov [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Banerjee, Swagato [Department of Physics, University of Wisconsin, Madison, WI, United States of America (United States); Brandt, Gerhard; Carney, Rebecca; Garcia-Sciveres, Maurice [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Hard, Andrew Straiton; Kaplan, Laser Seymour; Kashif, Lashkar [Department of Physics, University of Wisconsin, Madison, WI, United States of America (United States); Pranko, Aliaksandr [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Rieger, Julia [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); II Physikalisches Institut, Georg-August-Universität, Göttingen (Germany); Wolf, Julian [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Wu, Sau Lan; Yang, Hongtao [Department of Physics, University of Wisconsin, Madison, WI, United States of America (United States)

    2016-09-21

    In order to enable the ATLAS experiment to successfully track charged particles produced in high-energy collisions at the High-Luminosity Large Hadron Collider, the current ATLAS Inner Detector will be replaced by the Inner Tracker (ITk), entirely composed of silicon pixel and strip detectors. An extension of the tracking coverage of the ITk to very forward pseudorapidity values is proposed, using pixel modules placed in a long cylindrical layer around the beam pipe. The measurement of long pixel clusters, detected when charged particles cross the silicon sensor at small incidence angles, has potential to significantly improve the tracking efficiency, fake track rejection, and resolution of the ITk in the very forward region. The performance of state-of-the-art pixel modules at small track incidence angles is studied using test beam data collected at SLAC and CERN. - Highlights: • Extended inner pixel barrel layers are proposed for the ATLAS ITk upgrade. • Test beam results at small track incidence angles validate this ATLAS ITk design. • Long pixel clusters are reconstructed with high efficiency at low threshold values. • Excellent angular resolution is achieved using pixel cluster length information.

  3. Performance of silicon pixel detectors at small track incidence angles for the ATLAS Inner Tracker upgrade

    International Nuclear Information System (INIS)

    Viel, Simon; Banerjee, Swagato; Brandt, Gerhard; Carney, Rebecca; Garcia-Sciveres, Maurice; Hard, Andrew Straiton; Kaplan, Laser Seymour; Kashif, Lashkar; Pranko, Aliaksandr; Rieger, Julia; Wolf, Julian; Wu, Sau Lan; Yang, Hongtao

    2016-01-01

    In order to enable the ATLAS experiment to successfully track charged particles produced in high-energy collisions at the High-Luminosity Large Hadron Collider, the current ATLAS Inner Detector will be replaced by the Inner Tracker (ITk), entirely composed of silicon pixel and strip detectors. An extension of the tracking coverage of the ITk to very forward pseudorapidity values is proposed, using pixel modules placed in a long cylindrical layer around the beam pipe. The measurement of long pixel clusters, detected when charged particles cross the silicon sensor at small incidence angles, has potential to significantly improve the tracking efficiency, fake track rejection, and resolution of the ITk in the very forward region. The performance of state-of-the-art pixel modules at small track incidence angles is studied using test beam data collected at SLAC and CERN. - Highlights: • Extended inner pixel barrel layers are proposed for the ATLAS ITk upgrade. • Test beam results at small track incidence angles validate this ATLAS ITk design. • Long pixel clusters are reconstructed with high efficiency at low threshold values. • Excellent angular resolution is achieved using pixel cluster length information.

  4. A gas ionisation Direct-STIM detector for MeV ion microscopy

    International Nuclear Information System (INIS)

    Norarat, Rattanaporn; Guibert, Edouard; Jeanneret, Patrick; Dellea, Mario; Jenni, Josef; Roux, Adrien; Stoppini, Luc; Whitlow, Harry J.

    2015-01-01

    Direct-Scanning Transmission Ion Microscopy (Direct-STIM) is a powerful technique that yields structural information in sub-cellular whole cell imaging. Usually, a Si p-i-n diode is used in Direct-STIM measurements as a detector. In order to overcome the detrimental effects of radiation damage which appears as a broadening in the energy resolution, we have developed a gas ionisation detector for use with a focused ion beam. The design is based on the ETH Frisch grid-less off-axis Geiger–Müller geometry. It is developed for use in a MeV ion microscope with a standard Oxford Microbeams triplet lens and scanning system. The design has a large available solid angle for other detectors (e.g. proton induced fluorescence). Here we report the performance for imaging ReNcells VM with μm resolution where energy resolutions of <24 keV fwhm could be achieved for 1 MeV protons using isobutane gas

  5. Directly-deposited blocking filters for high-performance silicon x-ray detectors

    Science.gov (United States)

    Bautz, M.; Kissel, S.; Masterson, R.; Ryu, K.; Suntharalingam, V.

    2016-07-01

    Silicon X-ray detectors often require blocking filters to mitigate noise and out-of-band signal from UV and visible backgrounds. Such filters must be thin to minimize X-ray absorption, so direct deposition of filter material on the detector entrance surface is an attractive approach to fabrication of robust filters. On the other hand, the soft (E OD 6) care must be taken to prevent light from entering the sides and mounting surfaces of the detector. Our methods have been used to deposit filters on the detectors of the REXIS instrument scheduled to fly on OSIRIS-ReX later this year.

  6. Can direct electron detectors outperform phosphor-CCD systems for TEM?

    Energy Technology Data Exchange (ETDEWEB)

    Moldovan, G; Li, X; Kirkland, A [Department of Materials, University of Oxford, Parks Road, Oxford, 0X1 3PH (United Kingdom)], E-mail: grigore.moldovan@materials.ox.ac.uk

    2008-08-15

    A new generation of imaging detectors is being considered for application in TEM, but which device architectures can provide the best images? Monte Carlo simulations of the electron-sensor interaction are used here to calculate the expected modulation transfer of monolithic active pixel sensors (MAPS), hybrid active pixel sensors (HAPS) and double sided Silicon strip detectors (DSSD), showing that ideal and nearly ideal transfer can be obtained using DSSD and MAPS sensors. These results highly recommend the replacement of current phosphor screen and charge coupled device imaging systems with such new directly exposed position sensitive electron detectors.

  7. Method of incident low-energy gamma-ray direction reconstruction in the GAMMA-400 gamma-ray space telescope

    International Nuclear Information System (INIS)

    Kheymits, M D; Leonov, A A; Zverev, V G; Galper, A M; Arkhangelskaya, I V; Arkhangelskiy, A I; Yurkin, Yu T; Bakaldin, A V; Suchkov, S I; Topchiev, N P; Dalkarov, O D

    2016-01-01

    The GAMMA-400 gamma-ray space-based telescope has as its main goals to measure cosmic γ-ray fluxes and the electron-positron cosmic-ray component produced, theoretically, in dark-matter-particles decay or annihilation processes, to search for discrete γ-ray sources and study them in detail, to examine the energy spectra of diffuse γ-rays — both galactic and extragalactic — and to study gamma-ray bursts (GRBs) and γ-rays from the active Sun. Scientific goals of GAMMA-400 telescope require fine angular resolution. The telescope is of a pair-production type. In the converter-tracker, the incident gamma-ray photon converts into electron-positron pair in the tungsten layer and then the tracks are detected by silicon- strip position-sensitive detectors. Multiple scattering processes become a significant obstacle in the incident-gamma direction reconstruction for energies below several gigaelectronvolts. The method of utilising this process to improve the resolution is proposed in the presented work. (paper)

  8. Analysis of the direct x-ray absorption noise in phosphor-coupled CMOS detectors

    International Nuclear Information System (INIS)

    Han, Jong Chul; Yun, Seung Man; Kim, Ho Kyung; Cunningham, Ian; Achterkirchen, Thorsten

    2009-01-01

    It is known that the indirect conversion detectors have an NPS (noise power spectrum), which decreases with the spatial frequency, and the direct conversion detector have a nearly constant NPS with the spatial frequency (or white NPS). This explains that when a significant amount of x rays are not absorbed in the phosphor layer, then the additional absorption of x-rays in the semiconductor layers (or the photodiodes) with their white noise contributions degrades the total NPS performance. From the fact, we investigated how the direct x-ray affects CMOS detectors in terms of NPS and DQE (detective quantum efficiency)

  9. Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1995-11-01

    The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with open-quotes single carrierclose quotes response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation measurement capabilities provided in our laboratory in the Phoenix Building on the North Campus. In addition to our laboratory based activities, Professor Knoll has also been a participant in several Department of Energy review activities held in the Forrestal Building and at the Germantown site. The most recent of these has been service on a DOE review panel chaired by Dr. Hap Lamonds that is reviewing the detector development programs supported through the Office of Arms Control and International Security

  10. Directional gamma sensing from covariance processing of inter-detector Compton crosstalk energy asymmetries

    Energy Technology Data Exchange (ETDEWEB)

    Trainham, R., E-mail: trainhcp@nv.doe.gov; Tinsley, J. [Special Technologies Laboratory of National Security Technologies, LLC, 5520 Ekwill Street, Santa Barbara, California 93111 (United States)

    2014-06-15

    Energy asymmetry of inter-detector crosstalk from Compton scattering can be exploited to infer the direction to a gamma source. A covariance approach extracts the correlated crosstalk from data streams to estimate matched signals from Compton gammas split over two detectors. On a covariance map the signal appears as an asymmetric cross diagonal band with axes intercepts at the full photo-peak energy of the original gamma. The asymmetry of the crosstalk band can be processed to determine the direction to the radiation source. The technique does not require detector shadowing, masking, or coded apertures, thus sensitivity is not sacrificed to obtain the directional information. An angular precision of better than 1° of arc is possible, and processing of data streams can be done in real time with very modest computing hardware.

  11. Locating gamma radiation source by self collimating BGO detector system

    Energy Technology Data Exchange (ETDEWEB)

    Orion, I; Pernick, A; Ilzycer, D; Zafrir, H [Israel Atomic Energy Commission, Yavne (Israel). Soreq Nuclear Research Center; Shani, G [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    The need for airborne collimated gamma detector system to estimate the radiation released from a nuclear accident has been established. A BGO detector system has been developed as an array of separate seven cylindrical Bismuth Germanate scintillators, one central detector symmetrically surrounded by six detectors. In such an arrangement, each of the detectors reduced the exposure of other detectors in the array to a radiation incident from a possible specific spatial angle, around file array. This shielding property defined as `self-collimation`, differs the point source response function for each of the detectors. The BGO detector system has a high density and atomic number, and therefore provides efficient self-collimation. Using the response functions of the separate detectors enables locating point sources as well as the direction of a nuclear radioactive plume with satisfactory angular resolution, of about 10 degrees. The detector`s point source response, as function of the source direction, in a horizontal plane, has been predicted by analytical calculation, and was verified by Monte-Carlo simulation using the code EGS4. The detector`s response was tested in a laboratory-scale experiment for several gamma ray energies, and the experimental results validated the theoretical (analytical and Monte-Carlo) results. (authors).

  12. A multi-panel direction-sensitive gamma-ray detector for low-altitude radiological searches

    Energy Technology Data Exchange (ETDEWEB)

    Becker, E.M.; Farsoni, A.T.

    2016-11-11

    A lightweight, low-cost multi-panel direction-sensitive radiation detector prototype has been developed at Oregon State University that is designed to be mounted on a small unmanned aerial system to autonomously search for radiation sources while flying close to the ground. The detection system comprises sixteen BGO-SiPM detector panels with an adjustable view angle, and signal outputs are processed in parallel in an FPGA. The minimum detectable activity was calculated to be 1.3 μCi of {sup 137}Cs at 1 m in under 60 s. The counting response of the detector panels were characterized and found to have 4.7% relative standard deviation, indicating good uniformity in overall design and assembly. The detector was also able to estimate the direction of a 12.3 μCi {sup 137}Cs source 100 cm from the device center with 2.3° accuracy in a 95% confidence width of 10.8° in 60 s.

  13. A scintillating fibre detector for the Crystal Barrel experiment at ELSA

    International Nuclear Information System (INIS)

    Suft, G.; Anton, G.; Bogendoerfer, R.; Ehmanns, A.; Foesel, A.; Hoessl, J.; Kalinowsky, H.; Kueppersbusch, C.; Walther, D.

    2005-01-01

    A scintillating fibre detector with high spatial granularity was built for the Crystal Barrel experiment at ELSA (CB-ELSA) in Bonn. It consists of 513 scintillating fibres with 2mm in diameter, arranged in three layers with cylindrical geometry inside the Crystal Barrel detector surrounding the target cell. Two layers are wound in opposite directions, the third is parallel to the incident beam direction, resulting in an unambiguous hit reconstruction and a position resolution better than 1.6mm for charged particles. The read-out is done with 16-channel multi-anode photomultipliers. The detector was designed to cover the full angular acceptance of the Crystal Barrel detector with an angular range of 12 deg. ≤θ = 168 deg. and 0 deg. ≤φ≤360 deg. in the lab frame

  14. Advancements in the development of a directional-position sensing fast neutron detector using acoustically tensioned metastable fluids

    Energy Technology Data Exchange (ETDEWEB)

    Archambault, Brian C. [Sagamore Adams Laboratories, Lafayette, IN (United States); Webster, Jeffrey A.; Grimes, Thomas F.; Fischer, Kevin F.; Hagen, Alex R. [School of Nuclear Engineering, Purdue University, 400 Central Avenue, West Lafayette, IN 47907 (United States); Taleyakhan, Rusi P., E-mail: rusi@purdue.edu [Sagamore Adams Laboratories, Lafayette, IN (United States); School of Nuclear Engineering, Purdue University, 400 Central Avenue, West Lafayette, IN 47907 (United States)

    2015-06-01

    Advancements in the development of a direction and position sensing fast neutron detector which utilizes the directional acoustic tensioned metastable fluid detector (D-ATMFD) are described. The resulting D-ATMFD sensor is capable of determining the direction of neutron radiation with a single compact detector versus use of arrays of detectors in conventional directional systems. Directional neutron detection and source positioning offer enhanced detection speeds in comparison to traditional proximity searching; including enabling determination of the neutron source shape, size, and strength in near real time. This paper discusses advancements that provide the accuracy and precision of ascertaining directionality and source localization information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on-demand enlargement capability of the detector sensitive volume. These advancements were accomplished utilizing experimentation and theoretical modeling. Benchmarking and qualifications studies were successfully conducted with random and fission based special nuclear material (SNM) neutron sources ({sup 239}Pu–Be and {sup 252}Cf). These results of assessments have indicated that the D-ATMFD compares well in technical performance with banks of competing directional fast neutron detector technologies under development worldwide, but it does so with a single detector unit, an unlimited field of view, and at a significant reduction in both cost and size while remaining completely blind to common background (e.g., beta-gamma) radiation. Rapid and direct SNM neutron source imaging with two D-ATMFD sensors was experimentally demonstrated, and furthermore, validated via multidimensional nuclear particle transport simulations utilizing MCNP-PoliMi. Characterization of a scaled D-ATMFD based radiation portal monitor (RPM) as a cost-effective and efficient {sup 3}He sensor replacement was performed utilizing MCNP-PoliMi simulations

  15. Experimental observation of the improvement in MTF from backthinning a CMOS direct electron detector

    International Nuclear Information System (INIS)

    McMullan, G.; Faruqi, A.R.; Henderson, R.; Guerrini, N.; Turchetta, R.; Jacobs, A.; Hoften, G. van

    2009-01-01

    The advantages of backthinning monolithic active pixel sensors (MAPS) based on complementary metal oxide semiconductor (CMOS) direct electron detectors for electron microscopy have been discussed previously; they include better spatial resolution (modulation transfer function or MTF) and efficiency at all spatial frequencies (detective quantum efficiency or DQE). It was suggested that a 'thin' CMOS detector would have the most outstanding properties because of a reduction in the proportion of backscattered electrons. In this paper we show, theoretically (using Monte Carlo simulations of electron trajectories) and experimentally that this is indeed the case. The modulation transfer functions of prototype backthinned CMOS direct electron detectors have been measured at 300 keV. At zero spatial frequency, in non-backthinned 700-μm-thick detectors, the backscattered component makes up over 40% of the total signal but, by backthinning to 100, 50 or 35 μm, this can be reduced to 25%, 15% and 10%, respectively. For the 35 μm backthinned detector, this reduction in backscatter increases the MTF by 40% for spatial frequencies between 0.1 and 1.0 Nyquist. As discussed in the main text, reducing backscattering in backthinned detectors should also improve DQE.

  16. Design of a portable directional neutron source finder

    International Nuclear Information System (INIS)

    Yamanishi, Hirokuni

    2005-01-01

    An instrument that determines the direction of a remote existing neutron source has been designed. This instrument combines a polyethylene block and four 3 He counter tubes. The advantages of the instrument are portability and good angular resolution. The count from the detector was varied with the neutron incident angle due to the moderator. Using this characteristic, the direction of the neutron source can be measured precisely by revising the axis of the instrument so that the difference between the four detectors measurements is minimized. Consequently, the direction of the central axis of the instrument in which the response difference of the four detectors reaches a minimum indicates the direction of the neutron source. The practical use of the instrument was demonstrated by 252 Cf source irradiation experiment and MCNP simulation

  17. Multi-directional radiation detector using photographic film

    International Nuclear Information System (INIS)

    Junet, L K; Majid, Z A Abdul; Sapuan, A H; Sayed, I S; Pauzi, N F

    2014-01-01

    Ionising radiation has always been part of our surrounding and people are continuously exposed to it. Ionising radiation is harmful to human health, thus it is vital to monitor the radiation. To monitor radiation, there are three main points that should be observed cautiously, which are energy, quantity, and direction of the radiation sources. A three dimensional (3D) dosimeter is an example of a radiation detector that provide these three main points. This dosimeter is able to record the radiation dose distribution in 3D. Applying the concept of dose detection distribution, study has been done to design a multi-directional radiation detector of different filter thicknesses. This is obtained by designing a cylinder shaped aluminum filter with several layers of different thickness. Black and white photographic material is used as a radiation-sensitive material and a PVC material has been used as the enclosure. The device is then exposed to a radiation source with different exposure factors. For exposure factor 70 kVp, 16 mAs; the results have shown that optical density (OD) value at 135° is 1.86 higher compared with an OD value at 315° which is 0.71 as the 135° area received more radiation compare to 315° region. Furthermore, with an evidence of different angle of film give different value of OD shows that this device has a multidirectional ability. Materials used to develop this device are widely available in the market, thus reducing the cost of development and making it suitable for commercialisation

  18. Solid state radiation detector system

    International Nuclear Information System (INIS)

    1977-01-01

    A solid state radiation flux detector system utilizes a detector element, consisting of a bar of semiconductor having electrical conductance of magnitude dependent upon the magnitude of photon and charged particle flux impinging thereon, and negative feedback circuitry for adjusting the current flow through a light emitting diode to facilitate the addition of optical flux, having a magnitude decreasing in proportion to any increase in the magnitude of radiation (e.g. x-ray) flux incident upon the detector element, whereby the conductance of the detector element is maintained essentially constant. The light emitting diode also illuminates a photodiode to generate a detector output having a stable, highly linear response with time and incident radiation flux changes

  19. The digital flat-panel X-Ray detectors

    International Nuclear Information System (INIS)

    Risticj, S. Goran

    2013-01-01

    In a digital imaging system, the incident x-ray image must be sampled both in the spatial and intensity dimensions. In the spatial dimensions, samples are obtained as averages of the intensity over picture elements or pixels. In the intensity dimension, the signal is digitalized into one of a finite number of levels or bits. Two main types of digital flat-panel detectors are based on the direct conversion, which contains the photoconductor, and on indirect conversion, which contains phosphor. The basics of these detectors are given. Coupling traditional x-ray detection material such as photoconductors and phosphors with a large-area active-matrix readout structure forms the basis of flat panel x-ray images. Active matrix technology provides a new, highly efficient, real time method for electronically storing and measuring the product of the x-ray interaction stage whether the product is visible wavelength photons or electrical charges. The direct and indirect detectors, made as the active-matrix flat-panel detectors containing sensing/storage elements, switching elements (diodes or thin film transistors (TFTS)) and image processing module, are described. Strengths and limitations of stimulable phosphors are discussed. The main advantages and disadvantages of mentioned x-ray detectors are also analyzed. (Author)

  20. Development of a modular directional and spectral neutron detection system using solid-state detectors

    Energy Technology Data Exchange (ETDEWEB)

    Weltz, A., E-mail: weltza3@gmail.com; Torres, B.; McElwain, L.; Dahal, R.; Huang, J.; Bhat, I.; Lu, J.; Danon, Y.

    2015-08-21

    A detection system using room-temperature, microstructured solid-state thermal neutron detectors with very low leakage current has been developed at Rensselaer Polytechnic Institute (RPI) with the ability to provide positional and spectral information about an unknown neutron source. The Directional and Spectral Neutron Detection System (DSNDS) utilizes a set of small-but-scalable, zero-bias solid-state thermal neutron detectors which have demonstrated high thermal neutron efficiency and adequate gamma insensitivity. The DSNDS can gather spectral information about an unknown neutron source with a relatively small number of detectors, simplifying the detector electronics and minimizing cost; however, the DSNDS is modular in design, providing the capability to increase the detection efficiency and angular resolution. The system used in this paper was comprised of a stack of five high-density polyethylene (HDPE) disks with a thickness of 5 cm and a diameter of 30 cm, the middle disk containing 16 detectors positioned as one internal (moderated) and one external (unmoderated) ring of solid-state neutron detectors. These two detector rings provide the ability to determine the directionality of a neutron source. The system gathers spectral information about a neutron source in two ways: by measuring the relative responses of the internal ring of detectors as well as measuring the ratio of the internal-to-external detector responses. Experiments were performed with variable neutron spectra: a {sup 252}Cf spontaneous fission neutron source which was HDPE moderated, HDPE reflected, lead (Pb) shielded, and bare in order to benchmark the system for spectral sensitivity. Simulations were performed in order to characterize the neutron spectra corresponding to each of the source configurations and showed agreement with experimental measurements. The DSNDS demonstrates the ability to determine the relative angle of the source and the hardness of the neutron spectrum. By using the

  1. Primary intestinal lymphangiectasia: Multiple detector computed tomography findings after direct lymphangiography.

    Science.gov (United States)

    Sun, Xiaoli; Shen, Wenbin; Chen, Xiaobai; Wen, Tingguo; Duan, Yongli; Wang, Rengui

    2017-10-01

    To analyse the findings of multiple detector computed tomography (MDCT) after direct lymphangiography in primary intestinal lymphangiectasia (PIL). Fifty-five patients with PIL were retrospectively reviewed. All patients underwent MDCT after direct lymphangiography. The pathologies of 16 patients were confirmed by surgery and the remaining 39 patients were confirmed by gastroendoscopy and/or capsule endoscopy. After direct lymphangiography, MDCT found intra- and extraintestinal as well as lymphatic vessel abnormalities. Among the intra- and extraintestinal disorders, 49 patients had varying degrees of intestinal dilatation, 46 had small bowel wall thickening, 9 had pleural and pericardial effusions, 21 had ascites, 41 had mesenteric oedema, 20 had mesenteric nodules and 9 had abdominal lymphatic cysts. Features of lymphatic vessel abnormalities included intestinal trunk reflux (43.6%, n = 24), lumbar trunk reflux (89.1%, n = 49), pleural and pulmonary lymph reflux (14.5%, n = 8), pericardial and mediastinal lymph reflux (16.4%, n = 9), mediastinal and pulmonary lymph reflux (18.2%, n = 10), and thoracic duct outlet obstruction (90.9%, n = 50). Multiple detector computed tomography after direct lymphangiography provides a safe and accurate examination method and is an excellent tool for the diagnosis of PIL. © 2017 The Royal Australian and New Zealand College of Radiologists.

  2. A directional fast neutron detector using scintillating fibers and an intensified CCD camera system

    International Nuclear Information System (INIS)

    Holslin, Daniel; Armstrong, A.W.; Hagan, William; Shreve, David; Smith, Scott

    1994-01-01

    We have been developing and testing a scintillating fiber detector (SFD) for use as a fast neutron sensor which can discriminate against neutrons entering at angles non-parallel to the fiber axis (''directionality''). The detector/convertor component is a fiber bundle constructed of plastic scintillating fibers each measuring 10 cm long and either 0.3 mm or 0.5 mm in diameter. Extensive Monte Carlo simulations were made to optimize the bundle response to a range of fast neutron energies and to intense fluxes of high energy gamma-rays. The bundle is coupled to a set of gamma-ray insenitive electro-optic intensifiers whose output is viewed by a CCD camera directly coupled to the intensifiers. Two types of CCD cameras were utilized: 1) a standard, interline RS-170 camera with electronic shuttering and 2) a high-speed (up to 850 frame/s) field-transfer camera. Measurements of the neutron detection efficiency and directionality were made using 14 MeV neutrons, and the response to gamma-rays was performed using intense fluxes from radioisotopic sources (up to 20 R/h). Recently, the detector was constructed and tested using a large 10 cm by 10 cm square fiber bundle coupled to a 10 cm diameter GEN I intensifier tube. We present a description of the various detector systems and report the results of experimental tests. ((orig.))

  3. A silicon pad shower maximum detector for a Shashlik calorimeter

    International Nuclear Information System (INIS)

    Alvsvaag, S.J.; Maeland, O.A.; Klovning, A.

    1995-01-01

    The new luminosity monitor of the DELPHI detector, STIC (Small angle TIle Calorimeter), was built using a Shashlik technique. This technique does not provide longitudinal sampling of the showers, which limits the measurement of the direction of the incident particles and the e-π separation. For these reasons STIC was equipped with a Silicon Pad Shower Maximum Detector (SPSMD). In order to match the silicon detectors to the Shashlick read out by wavelength shifter (WLS) fibers, the silicon wafers had to be drilled with a precision better than 10μm without damaging the active area of the detectors. This paper describes the SPSMD with emphasis on the fabrication techniques and on the components used. Some preliminary results of the detector performance from data taken with a 45GeV electron beam at CERN are presented. (orig.)

  4. Charged corpuscular beam detector

    Energy Technology Data Exchange (ETDEWEB)

    Hikawa, H; Nishikawa, Y

    1970-09-29

    The present invention relates to a charged particle beam detector which prevents transient phenomena disturbing the path and focusing of a charged particle beam travelling through a mounted axle. The present invention provides a charged particle beam detector capable of decreasing its reaction to the charge in energy of the charged particle beam even if the relative angle between the mounted axle and the scanner is unstable. The detector is characterized by mounting electrically conductive metal pieces of high melting point onto the face of a stepped, heat-resistant electric insulating material such that the pieces partially overlap each other and individually provide electric signals, whereby the detector is no longer affected by the beam. The thickness of the metal piece is selected so that an eddy current is not induced therein by an incident beam, thus the incident beam is not affected. The detector is capable of detecting a misaligned beam since the metal pieces partially overlap each other.

  5. MACHe3: A new generation detector for non-baryonic dark matter direct detection

    International Nuclear Information System (INIS)

    Santos, D.; Mayet, F.; Perrin, G.; Moulin, E.; Bunkov, Yu. M.; Godfrin, H.; Krusius, M.

    2002-01-01

    MACHe3 (MAtrix of Cells of superfluid 3 H e) is a project of a new detector for direct Dark Matter (DM) search, using superfluid 3 He as a sensitive medium. An experiment on a prototype cell has been performed and the st results reported here are encouraging to develop of a multicell prototype. In order to investigate the discovery potential of MACHe3, and its complementarity with other DM detectors, a phenomenological study done with the DarkSUSY code is shown. (authors)

  6. A Low-Noise Direct Incremental A/D Converter for FET-Based THz Imaging Detectors

    Directory of Open Access Journals (Sweden)

    Moustafa Khatib

    2018-06-01

    Full Text Available This paper presents the design, implementation and characterization results of a pixel-level readout chain integrated with a FET-based terahertz (THz detector for imaging applications. The readout chain is fabricated in a standard 150-nm CMOS technology and contains a cascade of a preamplification and noise reduction stage based on a parametric chopper amplifier and a direct analog-to-digital conversion by means of an incremental ΣΔ converter, performing a lock-in operation with modulated sources. The FET detector is integrated with an on-chip antenna operating in the frequency range of 325–375 GHz and compliant with all process design rules. The cascade of the FET THz detector and readout chain is evaluated in terms of responsivity and Noise Equivalent Power (NEP measurements. The measured readout input-referred noise of 1.6 μ V r m s allows preserving the FET detector sensitivity by achieving a minimum NEP of 376 pW/ Hz in the optimum bias condition, while directly providing a digital output. The integrated readout chain features 65-dB peak-SNR and 80-μ W power consumption from a 1.8-V supply. The area of the antenna-coupled FET detector and the readout chain fits a pixel pitch of 455 μm, which is suitable for pixel array implementation. The proposed THz pixel has been successfully applied for imaging of concealed objects in a paper envelope under continuous-wave illumination.

  7. Ascertaining directionality information from incident nuclear radiation

    Energy Technology Data Exchange (ETDEWEB)

    Archambault, Brian C. [Purdue University (United States); Lapinskas, Joseph R. [QSA Global, Inc. (United States); Wang Jing; Webster, Jeffrey A. [Purdue University (United States); McDeavitt, Sean [Texas A and M University (United States); Taleyarkhan, Rusi P., E-mail: rusi@purdue.edu [Purdue University (United States)

    2011-10-15

    Highlights: > Use of tensioned metastable fluids for detection of fast neutron radiation. > Monitored neutrons with 100% gamma photon blindness capability. > Monitored direction of incoming neutron radiation from special nuclear material emissions. > Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. > Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. > Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30{sup o} with 80% confidence; this required {approx}2000 detection events which could be collected within {approx}50 s at a detection rate of {approx}30-40 per second. Blind testing was

  8. Ascertaining directionality information from incident nuclear radiation

    International Nuclear Information System (INIS)

    Archambault, Brian C.; Lapinskas, Joseph R.; Wang Jing; Webster, Jeffrey A.; McDeavitt, Sean; Taleyarkhan, Rusi P.

    2011-01-01

    Highlights: → Use of tensioned metastable fluids for detection of fast neutron radiation. → Monitored neutrons with 100% gamma photon blindness capability. → Monitored direction of incoming neutron radiation from special nuclear material emissions. → Ascertained directionality of neutron source to within 30 deg. and with 80% confidence with 2000 detection events at rate of 30-40 per second. → Conducted successful blind test for determining source of neutrons from a hidden neutron emitting source. → Compared results with MCNP5-COMSOL based multi-physics model. - Abstract: Unprecedented capabilities for the detection of nuclear particles via tailored resonant acoustic systems such as the acoustic tensioned metastable fluid detection (ATMFD) systems were assessed for determining directionality of incoming fast neutrons. This paper presents advancements that expand on these accomplishments, thereby increasing the accuracy and precision of ascertaining directionality information utilizing enhanced signal processing-cum-signal analysis, refined computational algorithms, and on demand enlargement of the detector sensitive volume. Advances in the development of ATMFD systems were accomplished utilizing a combination of experimentation and theoretical modeling. Modeling methodologies include Monte-Carlo based nuclear particle transport using MCNP5 and multi-physics based assessments accounting for acoustic, structural, and electromagnetic coupling of the ATMFD system via COMSOL's multi-physics simulation platform. Benchmarking and qualification studies have been conducted with a 1 Ci Pu-Be neutron-gamma source. These results show that the specific ATMFD system used for this study can enable detection of directionality of incoming fast neutrons from the neutron source to within 30 o with 80% confidence; this required ∼2000 detection events which could be collected within ∼50 s at a detection rate of ∼30-40 per second. Blind testing was successfully

  9. A New Transition Radiation Detector for the CREAM experiment

    CERN Document Server

    Malinin, A; Angelaszek, D

    The Cosmic Ray Energetics And Mass (CREAM) experiment is designed to investigate the source, propagation and acceleration mechanism of high energy cosmic-ray nuclei, by directly measuring their energy and charge. Incorporating a Transition Radiation Detector (TRD) provides a model independent energy measurement complementary to the calorimeter, as well as additional track reconstruction capability. A new TRD design provides a compact, robust, reliable, low density detector to measure incident nucleus energy for 3 < Z < 26 nuclei in the Lorentz gamma factor range of 10 2 -10 5. The TRD design, R&D;, construction milestones, beam test results and a progress of the final TRD integration in the CREAM instrument are reported.

  10. A 10 MHz micropower CMOS front end for direct readout of pixel detectors

    International Nuclear Information System (INIS)

    Campbell, M.; Heijne, E.H.M.; Jarron, P.; Krummenacher, F.; Enz, C.C.; Declercq, M.; Vittoz, E.; Viertel, G.

    1990-01-01

    In the framework of the CERN-LAA project for detector R and D, a micropower circuit of 200 μmx200 μm with a current amplifier, a latched comparator and a digital memory element has been tested electrically and operated in connection with linear silicon detector arrays. The experimental direct-readout (DRO) chip comprises a matrix of 9x12 circuit cells and has been manufactured in a 3 μm CMOS technology. Particles and X-ray photons below 22 keV were detected, and thresholds can be set between 2000 and 20000 e - . The noise is less than 4 keV FWHM or 500 e - rms and the power dissipation per pixel element is 30 μW. The chip can be coupled to a detector matrix using bump bonding. (orig.)

  11. Low-dose electron energy-loss spectroscopy using electron counting direct detectors.

    Science.gov (United States)

    Maigné, Alan; Wolf, Matthias

    2018-03-01

    Since the development of parallel electron energy loss spectroscopy (EELS), charge-coupled devices (CCDs) have been the default detectors for EELS. With the recent development of electron-counting direct-detection cameras, micrographs can be acquired under very low electron doses at significantly improved signal-to-noise ratio. In spectroscopy, in particular in combination with a monochromator, the signal can be extremely weak and the detection limit is principally defined by noise introduced by the detector. Here we report the use of an electron-counting direct-detection camera for EEL spectroscopy. We studied the oxygen K edge of amorphous ice and obtained a signal noise ratio up to 10 times higher than with a conventional CCD.We report the application of electron counting to record time-resolved EEL spectra of a biological protein embedded in amorphous ice, revealing chemical changes observed in situ while exposed by the electron beam. A change in the fine structure of nitrogen K and the carbon K edges were recorded during irradiation. A concentration of 3 at% nitrogen was detected with a total electron dose of only 1.7 e-/Å2, extending the boundaries of EELS signal detection at low electron doses.

  12. Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, D.M., E-mail: dieter.schlosser@pnsensor.de [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Huth, M.; Hartmann, R. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Abboud, A.; Send, S. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Conka-Nurdan, T. [Türkisch-Deutsche Universität, Sakinkaya Cad. 86, Beykoz, 34820 Istanbul (Turkey); Shokr, M.; Pietsch, U. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Strüder, L. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany)

    2016-01-01

    By combining a low noise fully depleted pnCCD detector with a CsI(Tl) scintillator, an energy-dispersive area detector can be realized with a high quantum efficiency (QE) in the range from below 1 keV to above 100 keV. In direct detection mode the pnCCD exhibits a relative energy resolution of 1% at 122 keV and spatial resolution of less than 75 µm, the pixel size of the pnCCD. In the indirect detection mode, i.e. conversion of the incoming X-rays in the scintillator, the measured energy resolution was about 9–13% at 122 keV, depending on the depth of interaction in the scintillator, while the position resolution, extracted with the help of simulations, was 30 µm only. We show simulated data for incident photons of 122 keV and compare the various interaction processes and relevant physical parameters to experimental results obtained with a radioactive {sup 57}Co source. - Highlights: • Position and energy resolving pnCCD+CsI(Tl) detector for energies from 1-150 keV • Detection in the pnCCD (122keV): 1% energy and <75µm spatial resolution • Detection in the scintillator (122keV): 9-12% energy and ~30µm spatial resolution.

  13. Assembly of gamma radiation detection with directivity properties

    International Nuclear Information System (INIS)

    Stoica, M.; Talpalariu, C.

    2016-01-01

    An assembly of gamma radiation detection with directivity properties and small size enables the development of portable equipment or robots specialized in finding and signaling radioactively contaminated areas in case of nuclear incidents or decommissioning of nuclear installations. Directivity characteristic of the assembly of gamma radiation detection is very important when aiming to build an equipment for searching radioactively contaminated areas. In order to obtain a suitable directivity characteristics in terms of detection of gamma rays, it was necessary to construct a lead collimator with a cylindrical shape. The detector, preamplifier and amplifier pulse were placed inside the collimator and pulse discriminator circuit and power source were placed beside the collimator, all being disposed within the housing cylindrical experimental. A PIN photodiode type was used as a detector of gamma radiation. (authors)

  14. Prediction of sound transmission loss through multilayered panels by using Gaussian distribution of directional incident energy

    Science.gov (United States)

    Kang; Ih; Kim; Kim

    2000-03-01

    In this study, a new prediction method is suggested for sound transmission loss (STL) of multilayered panels of infinite extent. Conventional methods such as random or field incidence approach often given significant discrepancies in predicting STL of multilayered panels when compared with the experiments. In this paper, appropriate directional distributions of incident energy to predict the STL of multilayered panels are proposed. In order to find a weighting function to represent the directional distribution of incident energy on the wall in a reverberation chamber, numerical simulations by using a ray-tracing technique are carried out. Simulation results reveal that the directional distribution can be approximately expressed by the Gaussian distribution function in terms of the angle of incidence. The Gaussian function is applied to predict the STL of various multilayered panel configurations as well as single panels. The compared results between the measurement and the prediction show good agreements, which validate the proposed Gaussian function approach.

  15. Clinical evaluation of digital angiographic system equipped with the Safire' flat-panel detector of a direct conversion type

    International Nuclear Information System (INIS)

    Miura, Yoshiaki; Miura, Yusuke; Goto, Keiichi

    2003-01-01

    This report presents a report on clinical evaluation of our newly developed flat-panel X-ray detector of a direct conversion type, designed to provide images of a resolution higher than, or at least equal to, that ensured by X-ray photographic films, in clinical digital X-ray cinematography. This new detector was named 'Safire' the acronym of 'Shimadzu advanced flat imaging receptor', emphasizing its high technological level, such as the capability to ensure high quality of images. The clinical evaluation of Shimadzu DIGITEX Premier digital angiography system, equipped with this new flat-panel X-ray detector of a direct conversion type, has been started in March, 2003, at the Kokura Memorial Hospital in Kyushu, Japan. (author)

  16. Organic Scintillator Detector Response Simulations with DRiFT

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, Madison Theresa [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bates, Cameron Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mckigney, Edward Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rising, Michael Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pinilla, Maria Isabel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Solomon, Jr., Clell Jeffrey [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sood, Avneet [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-19

    Accurate detector modeling is a requirement to design systems in many non-proliferation scenarios; by determining a Detector’s Response Function (DRF) to incident radiation, it is possible characterize measurements of unknown sources. DRiFT is intended to post-process MCNP® output and create realistic detector spectra. Capabilities currently under development include the simulation of semiconductor, gas, and (as is discussed in this work) scintillator detector physics. Energy spectra and pulse shape discrimination (PSD) trends for incident photon and neutron radiation have been reproduced by DRiFT.

  17. Radiation detector arrangements and methods

    International Nuclear Information System (INIS)

    Jackson, J.

    1989-01-01

    The patent describes a radiation detector arrangement. It comprises at least one detector element in the form of a temperature-sensitive resistor whose electrical resistance changes in response to radiation incident on the detector element, the resistor having a high positive temperature coefficient of electrical resistance at a transition in its electrical conductance, circuit means for applying a voltage across the resistor during operation of the detector arrangement, and temperature-regulation means for regulating the temperature of the resistor so as to operate the resistor in the transition, characterised in that the temperature-regulation means comprises the resistor and the circuit means which passes sufficient current through the resistor by resistance heating to a position in the transition at which a further increase in its temperature in response to incident radiation reduces the resistance heating by reducing the current, thereby stabilizing the temperature of the resistor at the position. The positive temperature coefficient at the position being sufficiently high that the change in the resistance heating produced by a change in the temperature of the resistor at the position is larger than a change in power of the incident radiation required to produce that same change in temperature of the resistor in the absence of any change in resistance heating

  18. Performance of 20:1 multiplexer for large area charge readouts in directional dark matter TPC detectors

    Science.gov (United States)

    Ezeribe, A. C.; Robinson, M.; Robinson, N.; Scarff, A.; Spooner, N. J. C.; Yuriev, L.

    2018-02-01

    More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels. A possible solution to reducing the overall cost of the charge readout electronics is to multiplex the signal readout channels. Here, we present a multiplexer system in expanded mode based on LMH6574 chips produced by Texas Instruments, originally designed for video processing. The setup has a capability of reducing the number of readouts in such TPC detectors by a factor of 20. Results indicate that the important charge distribution asymmetry along an ionization track is retained after multiplexed signals are demultiplexed.

  19. Modeling of Pixelated Detector in SPECT Pinhole Reconstruction.

    Science.gov (United States)

    Feng, Bing; Zeng, Gengsheng L

    2014-04-10

    A challenge for the pixelated detector is that the detector response of a gamma-ray photon varies with the incident angle and the incident location within a crystal. The normalization map obtained by measuring the flood of a point-source at a large distance can lead to artifacts in reconstructed images. In this work, we investigated a method of generating normalization maps by ray-tracing through the pixelated detector based on the imaging geometry and the photo-peak energy for the specific isotope. The normalization is defined for each pinhole as the normalized detector response for a point-source placed at the focal point of the pinhole. Ray-tracing is used to generate the ideal flood image for a point-source. Each crystal pitch area on the back of the detector is divided into 60 × 60 sub-pixels. Lines are obtained by connecting between a point-source and the centers of sub-pixels inside each crystal pitch area. For each line ray-tracing starts from the entrance point at the detector face and ends at the center of a sub-pixel on the back of the detector. Only the attenuation by NaI(Tl) crystals along each ray is assumed to contribute directly to the flood image. The attenuation by the silica (SiO 2 ) reflector is also included in the ray-tracing. To calculate the normalization for a pinhole, we need to calculate the ideal flood for a point-source at 360 mm distance (where the point-source was placed for the regular flood measurement) and the ideal flood image for the point-source at the pinhole focal point, together with the flood measurement at 360 mm distance. The normalizations are incorporated in the iterative OSEM reconstruction as a component of the projection matrix. Applications to single-pinhole and multi-pinhole imaging showed that this method greatly reduced the reconstruction artifacts.

  20. Improved method for estimating particle scattering probabilities to finite detectors for Monte Carlo simulation

    International Nuclear Information System (INIS)

    Mickael, M.; Gardner, R.P.; Verghese, K.

    1988-01-01

    An improved method for calculating the total probability of particle scattering within the solid angle subtended by finite detectors is developed, presented, and tested. The limiting polar and azimuthal angles subtended by the detector are measured from the direction that most simplifies their calculation rather than from the incident particle direction. A transformation of the particle scattering probability distribution function (pdf) is made to match the transformation of the direction from which the limiting angles are measured. The particle scattering probability to the detector is estimated by evaluating the integral of the transformed pdf over the range of the limiting angles measured from the preferred direction. A general formula for transforming the particle scattering pdf is derived from basic principles and applied to four important scattering pdf's; namely, isotropic scattering in the Lab system, isotropic neutron scattering in the center-of-mass system, thermal neutron scattering by the free gas model, and gamma-ray Klein-Nishina scattering. Some approximations have been made to these pdf's to enable analytical evaluations of the final integrals. These approximations are shown to be valid over a wide range of energies and for most elements. The particle scattering probability to spherical, planar circular, and right circular cylindrical detectors has been calculated using the new and previously reported direct approach. Results indicate that the new approach is valid and is computationally faster by orders of magnitude

  1. Development of a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography

    Science.gov (United States)

    Heo, D.; Jeon, S.; Kim, J.-S.; Kim, R. K.; Cha, B. K.; Moon, B. J.; Yoon, J.

    2013-02-01

    We developed a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography. The pixel resolution is 512 × 512 with 200 μm pixel and the overall active dimensions of the X-ray imaging panel is 10.24 cm × 10.24 cm. The detector consists of an X-ray absorption layer of amorphous selenium, a charge accumulation layer of metal, and a PID readout layer of amorphous silicon. In particular, the charge accumulation is pixelated because image charges generated by X-ray should be stored pixel by pixel. Here the image charges, or holes, are recombined with electrons generated by the PID method. We used a 405 nm laser diode and cylindrical lens to make a line beam source with a width of 50 μm for PID readout, which generates charges for each pixel lines during the scan. We obtained spatial frequencies of about 1.0 lp/mm for the X-direction (lateral direction) and 0.9 lp/mm for the Y-direction (scanning direction) at 50% modulation transfer function.

  2. Testing and Comparison of Imaging Detectors for Electrons in the Energy Range 10-20 keV

    Science.gov (United States)

    Matheson, J.; Moldovan, G.; Kirkland, A.; Allinson, N.; Abrahams, J. P.

    2017-11-01

    Interest in direct detectors for low-energy electrons has increased markedly in recent years. Detection of electrons in the energy range up to low tens of keV is important in techniques such as photoelectron emission microscopy (PEEM) and electron backscatter diffraction (EBSD) on scanning electron microscopes (SEMs). The PEEM technique is used both in the laboratory and on synchrotron light sources worldwide. The ubiquity of SEMs means that there is a very large market for EBSD detectors for materials studies. Currently, the most widely used detectors in these applications are based on indirect detection of incident electrons. Examples include scintillators or microchannel plates (MCPs), coupled to CCD cameras. Such approaches result in blurring in scintillators/phosphors, distortions in optical systems, and inefficiencies due the limited active area of MCPs. In principle, these difficulties can be overcome using direct detection in a semiconductor device. Growing out of a feasibility study into the use of a direct detector for use on an XPEEM, we have built at Rutherford Appleton Laboratory a system to illuminate detectors with an electron beam of energy up to 20 keV . We describe this system in detail. It has been used to measure the performance of a custom back-thinned monolithic active pixel sensor (MAPS), a detector based on the Medipix2 chip, and a commercial detector based on MCPs. We present a selection of the results from these measurements and compare and contrast different detector types.

  3. Dynamic prediction of cumulative incidence functions by direct binomial regression.

    Science.gov (United States)

    Grand, Mia K; de Witte, Theo J M; Putter, Hein

    2018-03-25

    In recent years there have been a series of advances in the field of dynamic prediction. Among those is the development of methods for dynamic prediction of the cumulative incidence function in a competing risk setting. These models enable the predictions to be updated as time progresses and more information becomes available, for example when a patient comes back for a follow-up visit after completing a year of treatment, the risk of death, and adverse events may have changed since treatment initiation. One approach to model the cumulative incidence function in competing risks is by direct binomial regression, where right censoring of the event times is handled by inverse probability of censoring weights. We extend the approach by combining it with landmarking to enable dynamic prediction of the cumulative incidence function. The proposed models are very flexible, as they allow the covariates to have complex time-varying effects, and we illustrate how to investigate possible time-varying structures using Wald tests. The models are fitted using generalized estimating equations. The method is applied to bone marrow transplant data and the performance is investigated in a simulation study. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Simulating detectors dead time

    International Nuclear Information System (INIS)

    Rustom, Ibrahim Farog Ibrahim

    2015-06-01

    Nuclear detectors are used in all aspects of nuclear measurements. All nuclear detectors are characterized by their dead time i.e. the time needed by a detector to recover from a previous incident. A detector dead time influences measurements taken by a detector and specially when measuring high decay rate (>) where is the detector dead time. Two models are usually used to correct for the dead time effect: the paralayzable and the non-paralayzable models. In the current work we use Monte Carlo simulation techniques to simulate radioactivity and the effect of dead time and the count rate of a detector with a dead time =5x10 - 5s assuming the non-paralayzable model. The simulation indicates that assuming a non -paralayzable model could be used to correct for decay rate measured by a detector. The reliability of the non-paralayzable model to correct the measured decay rate could be gauged using the Monte Carlo simulation. (Author)

  5. MICAP, Ionization Chamber Detector Response by Monte-Carlo

    International Nuclear Information System (INIS)

    2002-01-01

    1 - Description of program or function: MICAP has been developed to determine the response of a gas-filled cavity ionization chamber or other detector type (plastic scintillator, calorimeter) in a mixed neutron and photon radiation environment. In particular, MICAP determines the neutron, photon, and total response of the detector system. The applicability of MICAP encompasses all aspects of mixed field dosimetry analysis including detector design, pre-experimental planning and post-experimental analysis. MICAP is a modular code system developed to be general with respect to problem applicability The transport modules utilize combinatorial geometry to accurately model the source/detector geometry and also use continuous energy and angle cross section and material data to represent the materials for a particular problem. 2 - Method of solution: The calculational scheme used in MICAP follows individual radiation particles incident on the detector wall material. The incident neutrons produce photons and heavy charged particles, and both primary and secondary photons produce electrons and positrons. As these charged particles enter or are produced in the detector material, they lose energy and produce ion pairs until their energy is completely dissipated or until they escape the detector. Ion recombination effects are included along the path of each charged particle rather than applied as an integral correction to the final result. The neutron response is determined from the energy deposition resulting from the transport of the charged particles and recoil heavy ions produced via the neutron interactions with the detector materials. The photon response is determined from the transport of both the primary photon radiation incident on the detector and also the secondary photons produced via the neutron interactions. MICAP not only yields the energy deposition by particle type and total energy deposited, but also the particular type of reaction, i.e. elastic scattering

  6. Forbush decreases on November 6-12, 2004 observed by the Muon Detector Network

    Energy Technology Data Exchange (ETDEWEB)

    Savian, Jairo Francisco; Schuch, Nelson Jorge [Southern Regional Space Research Center, CRSPE/INPE-MCT, Santa Maria, RS (Brazil); Silva, Marlos Rockenbach da; Lago, Alisson dal; Echer, Ezequiel; Vieira, Luis Eduardo Antunes; Gonzalez, Walter Demetrio [National Institute for Space Research, INPE-MCT, Sao Jose dos Campos, SP (Brazil); Munakata, Kazuoki, E-mail: savian@lacesm.ufsm.br, E-mail: njschuch@lacesm.ufsm.br, E-mail: marlos@dge.inpe.br, E-mail: dallago@dge.inpe.br, E-mail: eecher@dge.inpe.br, E-mail: vieira-le@uol.com.br, E-mail: gonzalez@dge.inpe.br, E-mail: kmuna00@shinshu-u.ac.jp [Physics Department, Shinshu University, Matsumoto, (Japan)

    2007-07-01

    In this paper we study the relationship between interplanetary coronal mass ejections (ICMEs) and the muon count rate decreases detected of the muon detector network on November 6-12, 2004. The muon detector network is composed by the detectors installed at Nagoya (Japan), Hobart (Australia) and the prototype detector installed at the 'Observatorio Espacial do Sul - OES/CRSPE/INPE-MCT', located in Sao Martinho da Serra, RS, Brazil. With the muon count rate observed by the muon detector network, we will be able to observe, in the future, the direction in which a given ICME moves, and with that, we will be able to calculate their angle of incidence on the Earth. Also, with this muon network, we will be able to send alerts of up to 12 hours before the arrival of a shock or an ICME. The space weather forecast method using cosmic rays will be a very important tool because it provides a forecast with good antecedence. (author)

  7. Direct and inverse Staebler-Wronski effects observed in carbon-doped hydrogenated amorphous silicon photo-detectors

    International Nuclear Information System (INIS)

    Arce, P.; Barcala, J.M.; Calvo, E.; Ferrando, A.; Josa, M.I.; Molinero, A.; Navarrete, J.; Oller, J.C.; Yuste, C.; Brochero, J.; Calderon, A.; Fernandez, M.G.; Gomez, G.; Gonzalez-Sanchez, F.J.; Martinez-Rivero, C.; Matorras, F.; Rodrigo, T.; Ruiz-Arbol, P.; Scodellaro, L.; Sobron, M.

    2011-01-01

    The photo-response behaviour of Amorphous Silicon Position Detectors (ASPDs) under prolonged illumination with a 681 nm diode-laser and a 633 nm He-Ne laser is presented. Both direct and inverse Staebler-Wronski effects are observed.

  8. Searches for direct pair production of third generation squarks with the ATLAS detector

    CERN Document Server

    Mitrevski, Jovan; The ATLAS collaboration

    2018-01-01

    Naturalness arguments for weak-scale supersymmetry favour supersymmetric partners of the third generation quarks with masses not too far from those of their Standard Model counterparts. Top or bottom squarks with masses less than or around one TeV can also give rise to direct pair production rates at the LHC that can be observed in the data sample recorded by the ATLAS detector. The talk presents recent ATLAS results from searches for direct stop and sbottom pair production, using the data collected during the LHC Run 2.

  9. Searches for direct pair production of third generation squarks with the ATLAS detector

    CERN Document Server

    Mitrevski, Jovan; The ATLAS collaboration

    2018-01-01

    Naturalness arguments for weak-scale supersymmetry favour supersymmetric partners of the third generation quarks with masses not too far from those of their Standard Model counterparts. Top or bottom squarks with masses less than or around one TeV can also give rise to direct pair production rates at the LHC that can be observed in the data sample recorded by the ATLAS detector. The paper presents recent ATLAS results from searches for direct stop and sbottom pair production, using the data collected during the LHC Run 2.

  10. Clinical evaluation of digital angiographic system equipped with the Safire' flat-panel detector of a direct conversion type

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Yoshiaki; Miura, Yusuke; Goto, Keiichi [Shimadzu Corporation, Medical Systems Division, Research and Development, Kyoto (JP)] [and others

    2003-06-01

    This report presents a report on clinical evaluation of our newly developed flat-panel X-ray detector of a direct conversion type, designed to provide images of a resolution higher than, or at least equal to, that ensured by X-ray photographic films, in clinical digital X-ray cinematography. This new detector was named 'Safire' the acronym of 'Shimadzu advanced flat imaging receptor', emphasizing its high technological level, such as the capability to ensure high quality of images. The clinical evaluation of Shimadzu DIGITEX Premier digital angiography system, equipped with this new flat-panel X-ray detector of a direct conversion type, has been started in March, 2003, at the Kokura Memorial Hospital in Kyushu, Japan. (author)

  11. Test-beam and laboratory characterisation of the TORCH prototype detector

    CERN Document Server

    Ros, A; Castillo-Garcia, L; Conneely, T; Cussans, D; Foehl, K; Forty, R; Frei, C; Gao, R; Gys, T; Harnew, N; Milnes, J; Piedigrossi, D; Rademacker, J; Van Dijk, M

    2017-01-01

    The TORCH time-of-flight (TOF) detector is being developed to provide particle identification up to a momentum of 10 GeV/c over a flight distance of 10 m. It has a DIRC-like construction with View the MathML source10mm thick synthetic amorphous fused-silica plates as a Cherenkov radiator. Photons propagate by total internal reflection to the plate periphery where they are focused onto an array of customised position-sensitive micro-channel plate (MCP) detectors. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple photons. The MCPs have pixels of effective size 0.4 mm×6.6 mm2 in the vertical and horizontal directions, respectively, by incorporating a novel charge-sharing technique to improve the spatial resolution to better than the pitch of the readout anodes. Prototype photon detectors and readout electronics have been tested and calibrated in the laboratory. Preliminary results from testbeam measurements of a prototype TORCH detector are a...

  12. Fuel rod leak detector

    International Nuclear Information System (INIS)

    Womack, R.E.

    1978-01-01

    A typical embodiment of the invention detects leaking fuel rods by means of a radiation detector that measures the concentration of xenon-133 ( 133 Xe) within each individual rod. A collimated detector that provides signals related to the energy of incident radiation is aligned with one of the ends of a fuel rod. A statistically significant sample of the gamma radiation (γ-rays) that characterize 133 Xe is accumulated through the detector. The data so accumulated indicates the presence of a concentration of 133 Xe appropriate to a sound fuel rod, or a significantly different concentration that reflects a leaking fuel rod

  13. Neutron measurement in 12,13C+ 27Al system using CR-39 detectors and neutron rem meter

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Shanbhag, A.A.; Sunil, C.; Joshi, D.S.; Sarkar, P.K.

    2011-01-01

    In this work, neutron measurements carried out for the interaction of 60 and 67.5 MeV 12 C, 57.3 and 65 MeV 13 C ions with thick aluminium target by using CR-39 detectors and neutron rem meter is reported. Both the detector systems were irradiated at different angles viz. 0 deg, 30 deg, 60 deg, 90 deg with respect to the beam direction. The normalized track density measurements (tracks/cm 2 /projectile at 1m) in CR-39 detectors were correlated with the normalized dose equivalent values (μSv/projectile at 1m) obtained using the neutron rem meter. The track density was found to be more in case of 13 C than 12 C. However in all the cases, the track density per incident projectile was found to decrease as the angle with respect to beam direction increases, indicating non-isotropic nature of neutron emission. The ratio between measured dose equivalent in rem meter to the measured track densities in CR-39 detectors was found to be 2.8±0.2, which remains constant irrespective of the change in angle from beam direction as well as neutron spectrum, indicating a flat dose response of CR-39 detectors. (author)

  14. Direct photon-counting scintillation detector readout using an SSPM

    International Nuclear Information System (INIS)

    Stapels, Christopher J.; Squillante, Michael R.; Lawrence, William G.; Augustine, Frank L.; Christian, James F.

    2007-01-01

    Gamma-ray detector technologies, capable of providing adequate energy information, use photomultiplier tubes (PMTs) or silicon avalanche photodiodes to detect the light pulse from a scintillation crystal. A new approach to detect the light from scintillation materials is to use an array of small photon counting detectors, or a 'detector-on-a-chip' based on a novel 'Solid-state Photomultiplier' (SSPM) concept. A CMOS SSPM coupled to a scintillation crystal uses an array of CMOS Geiger photodiode (GPD) pixels to collect light and produce a signal proportional to the energy of the radiation. Each pixel acts as a binary photon detector, but the summed output is an analog representation of the total photon intensity. We have successfully fabricated arrays of GPD pixels in a CMOS environment, which makes possible the production of miniaturized arrays integrated with the detector electronics in a small silicon chip. This detector technology allows for a substantial cost reduction while preserving the energy resolution needed for radiological measurements. In this work, we compare designs for the SSPM detector. One pixel design achieves maximum detection efficiency (DE) for 632-nm photons approaching 30% with a room temperature dark count rate (DCR) of less than 1 kHz for a 30-μm-diameter pixel. We characterize after pulsing and optical cross talk and discuss their effects on the performance of the SSPM. For 30-μm diameter, passively quenched CMOS GPD pixels, modeling suggests that a pixel spacing of approximately 90 μm optimizes the SSPM performance with respect to DE and cross talk

  15. Development of a high-speed single-photon pixellated detector for visible wavelengths

    CERN Document Server

    Mac Raighne, Aaron; Mathot, Serge; McPhate, Jason; Vallerga, John; Jarron, Pierre; Brownlee, Colin; O’Shea, Val

    2009-01-01

    We present the development of a high-speed, single-photon counting, Hybrid Photo Detector (HPD). The HPD consists of a vacuum tube, containing the detector assembly, sealed with a transparent optical input window. Photons incident on the photocathode eject a photoelectron into a large electric field, which accelerates the incident electron onto a silicon detector. The silicon detector is bump bonded to a Medipix readout chip. This set-up allows for the detection and readout of low incident photon intensities at rates that are otherwise unattainable with current camera technology. Reported is the fabrication of the camera that brings together a range of sophisticated design and fabrication techniques and the expected theoretical imaging performance. Applications to cellular and molecular microscopy are also described in which single-photon-counting abilities at high frame rates are crucial

  16. Photodiodes selection for the VIRGO detector, the first step

    International Nuclear Information System (INIS)

    Caron, B.; Dominjon, A.; Flaminio, R.; Hermel, R.; Lacotte, J.C.; Marion, F.; Massonet, L.; Morand, R.; Mours, B.

    1994-07-01

    In the framework of the Gravitational Waves detector VIRGO, the photodetector system is under construction. The diodes that will be used must satisfy at the same time quite unusual criteria, among them a good quantum efficiency at a wavelength of 1.06 μm and a good linearity at MHz frequencies for an incident light power of 100 mW. The test method and the first very promising results obtained towards these directions with commercially available diodes in InGaAs are presented. (author). 3 refs., 6 figs., 2 tabs

  17. Detector on wheel system (flying spot)

    International Nuclear Information System (INIS)

    Annis, M.

    1980-01-01

    An arc-shaped x-ray beam penetrates an arcual cross-sectional area of a body and the attentuated transmitted beam irradiates a portion of a circular array of detectors on a rotating disc. The detectors operate to generate signals proportional to the intensity of the incident transmitted radiation. The beam and detectors are moved along the axis of the body during rotation of the disc to irradiate adjacent cross-sectional areas of the body. A computer operated crt receives the detector signals and displays an image of the radiation attentuation characteristics of the scanned arcual areas

  18. Diamond Pixel Detectors

    International Nuclear Information System (INIS)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D'Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Doroshenko, J.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foster, J.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Gobbi, B.; Grim, G.P.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Lander, R.; Logiudice, A.; Lu, R.; Lynne, L.M.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Perera, L.; Pirollo, S.; Plano, R.; Procario, M.; Riester, J.L.; Roe, S.; Rott, C.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Zoeller, M.

    2001-01-01

    Diamond based pixel detectors are a promising radiation-hard technology for use at the LHC. We present first results on a CMS diamond pixel sensor. With a threshold setting of 2000 electrons, an average pixel efficiency of 78% was obtained for normally incident minimum ionizing particles

  19. Diamond Pixel Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Adam, W.; Berdermann, E.; Bergonzo, P.; Bertuccio, G.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; D' Angelo, P.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Doroshenko, J.; Dulinski, W.; Eijk, B. van; Fallou, A.; Fizzotti, F.; Foster, J.; Foulon, F.; Friedl, M.; Gan, K.K.; Gheeraert, E.; Gobbi, B.; Grim, G.P.; Hallewell, G.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Koeth, T.; Krammer, M.; Lander, R.; Logiudice, A.; Lu, R.; Lynne, L.M.; Manfredotti, C.; Meier, D.; Mishina, M.; Moroni, L.; Oh, A.; Pan, L.S.; Pernicka, M.; Perera, L. E-mail: perera@physics.rutgers.edu; Pirollo, S.; Plano, R.; Procario, M.; Riester, J.L.; Roe, S.; Rott, C.; Rousseau, L.; Rudge, A.; Russ, J.; Sala, S.; Sampietro, M.; Schnetzer, S.; Sciortino, S.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R.J.; Tesarek, R.; Trischuk, W.; Tromson, D.; Vittone, E.; Wedenig, R.; Weilhammer, P.; White, C.; Zeuner, W.; Zoeller, M

    2001-06-01

    Diamond based pixel detectors are a promising radiation-hard technology for use at the LHC. We present first results on a CMS diamond pixel sensor. With a threshold setting of 2000 electrons, an average pixel efficiency of 78% was obtained for normally incident minimum ionizing particles.

  20. Searches for direct pair production of third generation squarks with the ATLAS detector

    CERN Document Server

    Anders, John Kenneth; The ATLAS collaboration

    2015-01-01

    Naturalness arguments for weak-scale supersymmetry favour supersymmetric partners of the third generation quarks with masses not too far from those of their Standard Model counterparts. Top or bottom squarks with masses less than a few hundred GeV can also give rise to direct pair production rates at the LHC that can be observed in the data sample recorded by the ATLAS detector. The talk presents a summary of the ATLAS results from searches for direct stop and sbottom pair production, using the data collected during LHC run1, as well as sensitivity projections for the data that will be collected in 2015.

  1. Beam Test Results for Single- and Double-Sided Silicon Detector Prototypes of the CMS Central Detector

    CERN Document Server

    Adriani, O

    1997-01-01

    We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics use was made of Preshape32, Premux128 and VA1 chips. The signal to noise ratio and the resolution of the detectors was studied for different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.

  2. DEPFET detectors for direct detection of MeV dark matter particles

    Energy Technology Data Exchange (ETDEWEB)

    Baehr, A.; Ninkovic, J.; Treis, J. [Max-Planck-Gesellschaft Halbleiterlabor, Munich (Germany); Kluck, H.; Schieck, J. [Institut fuer Hochenergiephysik, Oesterreichische Akademie der Wissenschaften, Vienna (Austria); Atominstitut, Technische Universitaet Wien, Vienna (Austria)

    2017-12-15

    The existence of dark matter is undisputed, while the nature of it is still unknown. Explaining dark matter with the existence of a new unobserved particle is among the most promising possible solutions. Recently dark matter candidates in the MeV mass region received more and more interest. In comparison to the mass region between a few GeV to several TeV, this region is experimentally largely unexplored. We discuss the application of a RNDR DEPFET semiconductor detector for direct searches for dark matter in the MeV mass region. We present the working principle of the RNDR DEPFET devices and review the performance obtained by previously performed prototype measurements. The future potential of the technology as dark matter detector is discussed and the sensitivity for MeV dark matter detection with RNDR DEPFET sensors is presented. Under the assumption of six background events in the region of interest and an exposure of 1 kg year a sensitivity of about anti σ{sub e} = 10{sup -41} cm{sup 2} for dark matter particles with a mass of 10 MeV can be reached. (orig.)

  3. Position sensitive detector with semiconductor and image electron tube comprising such a detector

    International Nuclear Information System (INIS)

    Roziere, Guy.

    1977-01-01

    This invention concerns a position sensitive detector comprising a semiconducting substrate. It also concerns the electron tubes in which the detector may be incorporated in order to obtain an image formed at the tube input by an incident flux of particles or radiation. When a charged particle or group of such particles, electrons in particular, enter the space charge region of an inversely biased semiconductor diode, the energy supplied by these particles releases in the diode a certain number of electron-hole pairs which move in the field existing in the area towards the diode contacts. A corresponding current arises in the connections of this diode which constitutes the signal corresponding to the incident energy. Such a tube or chain of tubes is employed in nuclear medicine for observing parts of the human body, particularly by gamma radiation [fr

  4. Research on self-powered detectors for gamma-ray monitoring

    International Nuclear Information System (INIS)

    Cho, S.W.; Lee, Y.J.

    1984-01-01

    Self-powered neutron detectors are used extensively in power reactors both for flux mapping and for power control and over-power protection, because of their small size, ruggedness and simplicity. But they have a few disadvantages such as high burn-up rate and background signal produced by the gamma-rays from the reactor itself. In order to overcome these disadvantages and to achieve a better understanding of gamma-ray effects of self-power detectors, a new type of self-powered detectors was designed and fabricated by the author,and experiments have carried out in the 10kCi sup(60)Co gamma irradiation facility in Korea Advanced Energy Research Institute. The configuration of the new type detectors is not of coaxial type but of paralled plate in order to obtain directional effects of gamma-ray incidence. Detector materials and dimensions are so chosen that the output current signal is large enough to be detected using some commercial measuring divice even at low dose rate and the contribution of the lead cable to the total signal is negligibly small. The results are 1)sensitivity is depended primarily on the materials of the insulator, 2)output signal has a good linearity to gamma dose rate, 3) response of detectors is prompt, but not perfect, 4) critical thickness for satusation of the output current is thinner than the range of photoelectron in the materials. (Author)

  5. Research on self-powered detectors for gamma-ray monitoring

    International Nuclear Information System (INIS)

    Cho, S.W.

    1983-01-01

    Self-powered neutron detectors are used extensively in power reactors both for flux mapping and for power control and over-power protection, because of their small size, ruggedness and simplicity. But they have a few disadvantages such as high burn-up rate and background signal produced by the gamma-rays from the reactor itself. In order to overcome these disadvantages and to achieve a better understanding of gamma-ray effects of self-powered detectors, a new type of self-powered detectors was designed and fabricated by the author, and experiments have been carried out in the 10kCi sup(60)Co gamma irradiation facility in Korea Advanced Energy Research Institute. The configuration of the new type detectors is not of coaxial type but of paralled plate in order to obtain directional effects of gamma-ray incidence. Detector materials and dimensions are so chosen that the output current signal is large enough to be detected using some commercial measuring divice even at low dose rate and the contribution of the lead cable to the totel signal is negligibly small. The results are 1) sensitivity is depended primarily on the materials of the insulator, 2) output signal has a good linearity to gamma dose rate, 3) response of detectors is prompt, but not perfect, 4) critical thickness for satusation of the output current is thinner than the range of photoelectron in the materials. (Author) πT

  6. Direct coupling of a liquid chromatograph to a continuous flow hydrogen nuclear magnetic resonance detector for analysis of petroleum and synthetic fuels

    International Nuclear Information System (INIS)

    Haw, J.F.; Glass, T.E.; Hausler, D.W.; Motell, E.; Dorn, H.C.

    1980-01-01

    Initial results obtained for a flow 1 H nuclear magnetic resonance (NMR) detector directly coupled to a liquid chromatography unit are described. Results achieved for a model mixture and several jet fuel samples are discussed. Chromatographic separation of alkanes, alkylbenzenes, and substituted naphthalenes present in the jet fuel samples are easily identified with the 1 H NMR detector. Results with our present flow 1 H NMR insert indicate that 5-Hz linewidths are readily obtainable for typical chromatographic flow rates. The limitations and advantages of this liquid chromatography detector are compared with more commonly employed detectors (e.g., refractive index detectors). 11 figures

  7. A detector for tomography by Compton scattering at 900 and tomography apparatus comprising such detector

    International Nuclear Information System (INIS)

    Ricodeau, Jean.

    1981-01-01

    The present invention concerns a detector for tomography by Compton scattering at 90 0 . The difference between this detector and those currently used previously lies in the fact that the collection aperture of the radiation at normal angle to the incident beam is large and can reach 180 0 and even more. This fact allows to collect an important part of the scattered radiation. A good image quality is obtained with low radiation doses delivered to the body as compared to previous techniques. This detector can be operated in analogical mode which presents the advantage to be faster and easier to realize [fr

  8. Predicting Cumulative Incidence Probability by Direct Binomial Regression

    DEFF Research Database (Denmark)

    Scheike, Thomas H.; Zhang, Mei-Jie

    Binomial modelling; cumulative incidence probability; cause-specific hazards; subdistribution hazard......Binomial modelling; cumulative incidence probability; cause-specific hazards; subdistribution hazard...

  9. Technical Note: Response measurement for select radiation detectors in magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, M., E-mail: michaelreynolds@ualberta.net [Department of Oncology, Medical Physics Division, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada); Fallone, B. G. [Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Departments of Oncology and Physics, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada); Rathee, S. [Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, Medical Physics Division,University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada)

    2015-06-15

    Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.

  10. A Post Shower detector for the FMS to study Drell Yan and Direct Photons

    Science.gov (United States)

    Kapukchyan, David; STAR Collaboration

    2017-09-01

    One of the goals of the 2017 run at STAR was to measure the direct photon and Drell Yan electrons in polarized pp collisions in order to understand the Sivers and Collins effects. To make such a measurement a postshower detector (FPOST) for the Forward Meson spectrometer (FMS) was commissioned and installed for the 2017 run. The FMS together with its preshower (FPS) detector and the new FPOST cover 2 FPS the FPOST is a scintillator hodoscope with a channel size that matches that of the FMS. Its purpose is to discriminate the hadrons that punch through and the partially contained showers that leak out of the FMS. This talk will discuss the design requirements and performance of the FPOST during the 2017 run. Funding by DOE Award No. DE-FG02-04ER41325.

  11. A novel method for assessing position-sensitive detector performance

    International Nuclear Information System (INIS)

    Clinthorne, N.H.; Rogers, W.L.; Shao, L.; Hero, A.O. III; Koral, K.F.

    1989-01-01

    A marked point process model of a position-sensitive detector is developed which includes the effects of detector efficiency, spatial response, energy response, and source statistics. The average mutual information between the incident distribution of γ rays and the detector response is derived and used as a performance index for detector optimization. A brief example is presented which uses this figure-of-merit for optimization of light guide dimensions for a modular scintillation camera

  12. Geographical Detector-Based Risk Factors Assessment of the Hand-Foot-Mouth Disease in China

    Science.gov (United States)

    Huang, J.

    2017-12-01

    Background: Hand, foot and mouth disease(HFMD) is a common infectious disease, causing thousands of deaths among children in China. This study focused on analyzing the impacts of different populations and different industry structures on HFMD incidence in China. Methods: We collected HFMD cases from 2307 counties during May 2008 in China. The potential risk factors included: monthly mean temperature, monthly mean relative humidity, monthly precipitation, different population density, different industry structures. Geographical detector technique was used to analyze the main and interactive effect of potential risk factors on HFMD incidence. Result: Using risk detector, we found the most serious HFMD incidence mainly located in the Yangtze River delta and the Pearl River delta. When the temperature was high, the incidence of HFMD was also high. This finding indicates that there is a correlation between monthly mean temperature and the incidence of HFMD. Similar analysis was undertaken to analyze the correlation between other variables and the incidence of HFMD using the risk detector. Using factor detector, we found the effect of risk factors on the incidence of HFMD, and this was ranked by PD value as follows: density of children aged 0-9 years (0.25) > tertiary industry (0.23) > GDP (0.20) >middle school student density (0.13) > relative humidity (0.12) >average temperature (0.11) >first industry (0.05). Using ecological detector, we found that child density, tertiary industry, and GDP had a strong effect on the incidence of HFMD. Using interactive detector, we found that the interactive PD value of tertiary industry and child population density was 0.42, which of GDP and tertiary industry was 0.34, that of child population density and GDP was 0.35, and that of average temperature and relative humidity was 0.28. All of these interactive PD values appeared to be higher than any PD value of sole risk factors. The combinations of the above-mentioned risk factors

  13. The Search for Highly Ionizing Particles in e$^{+}$e$^{-}$ Collisions at LEP using (MODAL) (MOnopole Detector At Lep)

    CERN Multimedia

    2002-01-01

    The experiment is designed to search for highly ionizing particles such as the monopole and the dyon. On the assumption that monopole-antimonopole pairs are produced via a virtual photon intermediate state, and have a mass in the range 0-100~GeV, a direct search for Dirac monopoles using e$^+$e$^-$ annihilation carries a distinct cross-sectional advantage over a search using hadron colliders.\\\\ \\\\ The MODAL detector is formed from Lexan/CR-39 dielectric track detector modules arranged in a polyhedral configuration outside of the vacuum pipe and around the intersection region, as shown on the opposite page. Etchable track detectors are more sensitive to particles at normal incidence, the shape of the detector was chosen with this fact in mind to allow for maximum acceptance of monopoles which leave the beam pipe. These dielectric track detectors will enable us to detect particles with magnetic charge: 20e$<$g$ _{d}

  14. Multiple detectors “Influence Method”

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015a). Its detailed mathematical description was recently published (Rios and Mayer, 2015b) and its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016). With the objective of further reducing the measurement uncertainties, in this article we extend the method for the case of multiple detectors placed one behind the other. The new estimators for the number of particles and the detection efficiency are herein derived. - Highlights: • “Multiple Detector Influence Method” developed for uncertainty reduction. • Absolute particle counting in absence of known detector efficiency. • Detector set efficiency determination.

  15. The 150 ns detector project: progress with small detectors

    International Nuclear Information System (INIS)

    Warburton, W.K.; Russell, S.R.; Kleinfelder, Stuart A.; Segal, Julie

    1994-01-01

    This project's long term goal is to develop a pixel area detector capable of 6 MHz frame rates (150 ns/frame). Our milestones toward this goal are: a single pixel, 1x256 1D and 8x8 2D detectors, 256x256 2D detectors and, finally, 1024x1024 2D detectors. The design strategy is to supply a complete electronics chain (resetting preamp, selectable gain amplifier, analog-to-digital converter (ADC), and memory) for each pixel. In the final detectors these will all be custom integrated circuits. The front end preamplifiers are being integrated first, since their design and performance are both the most unusual and also critical to the project's success. Similarly, our early work is also concentrating on devising and perfecting detector structures which are thick enough (1 mm) to absorb over 99% of the incident X-rays in the energy range of interest. In this paper we discuss our progress toward the 1x256 1D and 8x8 2D detectors. We have fabricated sample detectors at Stanford's Center for Integrated Systems and are preparing both to test them individually and to wirebond them to the preamplifier samples to produce our first working small 1D and 2D detectors. We will describe our solutions to the design problems associated with collecting charge in less than 30 ns from 1 mm thick pixels in high resistivity silicon. We have constructed and tested the front end of our preamplifier design using a commercial 1.2 μm CMOS technology and are moving on to produce a few channels of the complete preamplifier, including a switchable gain stage and output stage. We will discuss both the preamplifier design and our initial test results. ((orig.))

  16. The 150 ns detector project: progress with small detectors

    Energy Technology Data Exchange (ETDEWEB)

    Warburton, W.K. (X-ray Instrumentation Associates, 2513 Charleston Rd, Ste 207, Mountain View, CA 94043 (United States)); Russell, S.R. (X-ray Instrumentation Associates, 2513 Charleston Rd, Ste 207, Mountain View, CA 94043 (United States)); Kleinfelder, Stuart A. (VLSI Physics, 19 Drury Lane, Berkeley, CA 94705 (United States)); Segal, Julie (Integrated Ckts Lab., Dept. of Electrical Engineering, Stanford University, Stanford, CA 94305 (United States))

    1994-09-01

    This project's long term goal is to develop a pixel area detector capable of 6 MHz frame rates (150 ns/frame). Our milestones toward this goal are: a single pixel, 1x256 1D and 8x8 2D detectors, 256x256 2D detectors and, finally, 1024x1024 2D detectors. The design strategy is to supply a complete electronics chain (resetting preamp, selectable gain amplifier, analog-to-digital converter (ADC), and memory) for each pixel. In the final detectors these will all be custom integrated circuits. The front end preamplifiers are being integrated first, since their design and performance are both the most unusual and also critical to the project's success. Similarly, our early work is also concentrating on devising and perfecting detector structures which are thick enough (1 mm) to absorb over 99% of the incident X-rays in the energy range of interest. In this paper we discuss our progress toward the 1x256 1D and 8x8 2D detectors. We have fabricated sample detectors at Stanford's Center for Integrated Systems and are preparing both to test them individually and to wirebond them to the preamplifier samples to produce our first working small 1D and 2D detectors. We will describe our solutions to the design problems associated with collecting charge in less than 30 ns from 1 mm thick pixels in high resistivity silicon. We have constructed and tested the front end of our preamplifier design using a commercial 1.2 [mu]m CMOS technology and are moving on to produce a few channels of the complete preamplifier, including a switchable gain stage and output stage. We will discuss both the preamplifier design and our initial test results. ((orig.))

  17. Calibration of the hard x-ray detectors for the FOXSI solar sounding rocket

    Science.gov (United States)

    Athiray, P. S.; Buitrago-Casas, Juan Camilo; Bergstedt, Kendra; Vievering, Juliana; Musset, Sophie; Ishikawa, Shin-nosuke; Glesener, Lindsay; Takahashi, Tadayuki; Watanabe, Shin; Courtade, Sasha; Christe, Steven; Krucker, Säm.; Goetz, Keith; Monson, Steven

    2017-08-01

    The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket experiment conducts direct imaging and spectral observation of the Sun in hard X-rays, in the energy range 4 to 20 keV. These high-sensitivity observations are used to study particle acceleration and coronal heating. FOXSI is designed with seven grazing incidence optics modules that focus X-rays onto seven focal plane detectors kept at a 2m distance. FOXSI-1 was flown with seven Double-sided Si Strip Detectors (DSSD), and two of them were replaced with CdTe detectors for FOXSI-2. The upcoming FOXSI-3 flight will carry DSSD and CdTe detectors with upgraded optics for enhanced sensitivity. The detectors are calibrated using various radioactive sources. The detector's spectral response matrix was constructed with diagonal elements using a Gaussian approximation with a spread (sigma) that accounts for the energy resolution of the detector. Spectroscopic studies of past FOXSI flight data suggest that the inclusion of lower energy X-rays could better constrain the spectral modeling to yield a more precise temperature estimation of the hot plasma. This motivates us to carry out an improved calibration to better understand the finer-order effects on the spectral response, especially at lower energies. Here we report our improved calibration of FOXSI detectors using experiments and Monte-Carlo simulations.

  18. Time response measurements of LASL diagnostic detectors

    International Nuclear Information System (INIS)

    Hocker, L.P.

    1970-07-01

    The measurement and data analysis techniques developed under the Los Alamos Scientific Laboratory's detector improvement program were used to characterize the time and frequency response of selected LASL Compton, fluor-photodiode (NPD), and fluor-photomultiplier (NPM) diagnostic detectors. Data acquisition procedures and analysis methods presently in use are summarized, and detector time and frequency data obtained using the EG and G/AEC electron linear accelerator fast pulse (approximately 50 psec FWHM) as the incident radiation driving function are presented. (U.S.)

  19. The Global Muon Detector Network -GMDN and the space situational awareness

    Science.gov (United States)

    Schuch, Nelson Jorge; Munakata, Kazuoki; Dal Lago, Alisson; Marcos Denardini, Clezio; Echer, Ezequiel; Demítrio Gonzalez Alarcon, Walter; da Silva, Marlos; Rigozo, Nivaor R.; Petry, Adriano; Kirsch Pinheiro, Damaris; Braga, Carlos Roberto; Vinicius Dias Silveira, Marcos; Ronan Coelho Stekel, Tardelli; Espindola Antunes, Cassio; Ramos Vieira, Lucas; Kemmerich, Níkolas; Kato, Chihiro; Fushishita, Akira; Fujii, Zenjirou; Bieber, John W.; Evenson, Paul; Kuwabara, Takao; Duldig, Marcus L.; Humble, John E.; Chilingarian, Ashot; Sabbah, Ismail; Jansen, Frank

    hadronic interactions of primary GCRs (mostly protons) with atmospheric nuclei. Since muons have a relatively long life-time (about 2.2 mi-croseconds at rest) and can reach the detector at ground level preserving the incident direction of primary particles, the detector can measure the GCRs intensity in various directions with a multidirectional detector at a single location, such as in Brazil. The Brazilian muon detector (MD), at SSO, is a part of the GMDN, an international collaboration consisting of 10 insti-tutions from 6 countries, with real time data generated by the GMDN, which was developed at Shinshu University, Japan. With the expectation of the approval by European Commission of the NESTEC (NExt generation Space TEChnology) Project, the GMDN may be upgrade in 2010 including new muon detectors in Bremen, Germany and in Hermanus, South Africa. Therefore the ICMEs traveling in the interplanetary space and reaching the Earth -cause re-duction in cosmic ray counts at the Earth by one to ten percent, and can be detected sometimes as much as ten hours before their arrival at Earth -with the GMDN, thus permitting accurate and reliable Space Weather forecasting and for the space situational awareness.

  20. Charged particle discrimination with silicon surface barrier detectors

    International Nuclear Information System (INIS)

    Coote, G.E.; Pithie, J.; Vickridge, I.C.

    1996-01-01

    The application for materials analysis of nuclear reactions that give rise to charged particles is a powerful surface analytical and concentration depth profiling technique. Spectra of charged particles, with energies in the range 0.1 to 15 MeV, emitted from materials irradiated with beams of light nuclei such as deuterons are measured with silicon surface barrier detectors. The spectra from multi-elemental materials typically encountered in materials research are usually composed of an overlapping superposition of proton, alpha, and other charged particle spectra. Interpretation of such complex spectra would be simplified if a means were available to electronically discriminate between the detector response to the different kinds of charged particle. We have investigated two methods of discriminating between different types of charged particles. The fast charge pulses from a surface barrier detector have different shapes, depending on the spatial distribution of energy deposition of the incident particle. Fast digitisation of the pulses, followed by digital signal processing provides one avenue for discrimination. A second approach is to use a thin transmission detector in front of a thick detector as a detector telescope. For a given incident energy, different types of charged particles will lose different amounts of energy in the thin detector, providing an alternative means of discrimination. We show that both approaches can provide significant simplification in the interpretation of charged particle spectra in practical situations, and suggest that silicon surface barrier detectors having graded electronic properties could provide improved discrimination compared to the current generation of detectors having homogeneous electronic properties. (author).12 refs., 2 tabs., 28 figs

  1. Status of radiation detector and neutron monitor technology

    CERN Document Server

    Kim, Y K; Ha, J H; Han, S H; Hong, S B; Hwang, I K; Lee, W G; Moon, B S; Park, S H; Song, M H

    2002-01-01

    In this report, we describe the current states of the radiation detection technology, detectors for industrial application, and neutron monitors. We also survey the new technologies being applied to this field. The method to detect radiation is the measurement of the observable secondary effect from the interaction between incident radiation and detector material, such as ionization, excitation, fluorescence, and chemical reaction. The radiation detectors can be categorized into gas detectors, scintillation detectors, and semiconductor detectors according to major effects and main applications. This report contains the current status and operational principles of these detectors. The application fields of radiation detectors are industrial measurement system, in-core neutron monitor, medical radiation diagnostic device, nondestructive inspection device, environmental radiation monitoring, cosmic-ray measurement, security system, fundamental science experiment, and radiation measurement standardization. The st...

  2. Improved network monitoring using UTC detector data 'RAID'

    OpenAIRE

    Cherrett, Tom; Waterson, Ben; McDonald, Mike; Clarke, Russell; Bangert, Alex; Morris, Ray

    2002-01-01

    As part of the 5th Framework PRIME project1 (Prediction Of Congestion And Incidents In Real Time, For Intelligent Incident Management And Emergency Traffic Management), a new incident detection algorithm has been developed using the 250-ms digital data produced by UTC detectors. The contributors to this part of the project were the University of Southampton, Southampton City Council and Siemens Traffic Controls.

  3. Self-powered radiation detector

    International Nuclear Information System (INIS)

    Playfoot, K.C.; Bauer, R.F.; Goldstein, N.P.

    1980-01-01

    This invention relates to a self powered radiation detector requiring no excitation potential to generate a signal indicating a radiation flux. Such detectors comprise two electrically insulated electrodes, at a distance from each other. These electrodes are made of conducting materials having a different response for neutron and/or gamma ray radiation flux levels, as in nuclear power stations. This elongated detector generates an electric signal in terms of an incident flux of radiations cooperating with coaxial conductors insulated from each other and with different radiation reaction characteristics. The conductor with the greatest reaction to the radiations forms the central emitting electrode and the conductor with the least reaction to the radiations forms a tubular coaxial collecting electrode. The rhodium or cobalt tubular emitting electrode contains a ductile central conducting cable placed along the longitudinal axis of the detector. The latter is in high nickel steel with a low reaction to radiation [fr

  4. Fission signal detection using helium-4 gas fast neutron scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J. M., E-mail: lewisj@ufl.edu; Kelley, R. P.; Jordan, K. A. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611 (United States); Murer, D. [Arktis Radiation Detectors Ltd., 8045 Zurich (Switzerland)

    2014-07-07

    We demonstrate the unambiguous detection of the fission neutron signal produced in natural uranium during active neutron interrogation using a deuterium-deuterium fusion neutron generator and a high pressure {sup 4}He gas fast neutron scintillation detector. The energy deposition by individual neutrons is quantified, and energy discrimination is used to differentiate the induced fission neutrons from the mono-energetic interrogation neutrons. The detector can discriminate between different incident neutron energies using pulse height discrimination of the slow scintillation component of the elastic scattering interaction between a neutron and the {sup 4}He atom. Energy histograms resulting from this data show the buildup of a detected fission neutron signal at higher energies. The detector is shown here to detect a unique fission neutron signal from a natural uranium sample during active interrogation with a (d, d) neutron generator. This signal path has a direct application to the detection of shielded nuclear material in cargo and air containers. It allows for continuous interrogation and detection while greatly minimizing the potential for false alarms.

  5. Asymmetric rotator as a detector of monochromatic gravitational waves

    International Nuclear Information System (INIS)

    Gliner, Eh.B.; Mitrofanov, I.G.

    1979-01-01

    The interaction between a rotating asymmetric (principal moments of inertia are different) body with a gravitational wave is considered. A resonance rotational detector of monocrhomatic gravitational waves is proposed in which the turning due to the incident wave and the rotation which ensures resonance between the detector and wave correspond to different degrees of freedom. This significantly facilitates the creation of such detectors. The interference due to the gradient of the gravitational acceleration of the Earth and to rotation of the detector as a whole is estimated

  6. Propagation speed and incident direction of transient ionospheric disturbance (TID)

    International Nuclear Information System (INIS)

    Maeda, Sawako; Handa, Shun.

    1978-01-01

    It is well known that large scale transient ionospheric disturbance (ls-TID) of period from 20 min to 3 hours and spatial wave length from hundreds to thousands km among TID's is in close correlation to geomagnetic activity at high latitude. Since TID well agrees with the wave characteristic of internal gravitational waves, it has come to be considered that the internal gravitational waves excited by Lorentz's force and joule heating due to the ionospheric current in auroral zone at the time of substorm cause disturbances to ionosphere electron density. The authors have examined the propagation speed and incident direction of TID using the data observed at 5 min intervals of maximum electron density in F layer during IGY (international geophysical year). The data was processed through a band pass filter because only the waves with period from 20 min to 3 hours were required. Since two proposed modes for ls-TID have been discussed, whose dispersion properties are different, it is necessary to determine the propagation characteristics of ls-TID by observation, and to clarify the propagation mechanism of internal gravitational waves. Therefore, the dependence of propagation speed on period has been investigated. It is concluded that ls-TID was observed at the time of polar magnetic field disturbances, the average propagation speed was about 500 m/s and the incident direction was north-north east for the variation of from 20 min to 3 hours, and as for the dependence of propagation speed on period, the average speed was about 670 m/s for the long period change (approximately 100 min period), and about 440 m/s for short period change (approximately 30 min period) and the dispersion was observed. (Wakatsuki, Y.)

  7. Detector applications

    International Nuclear Information System (INIS)

    Pehl, R.H.

    1977-10-01

    Semiconductor detectors are now applied to a very wide range of problems. The combination of relatively low cost, excellent energy resolution, and simultaneous broad energy-spectrum analysis is uniquely suited to many applications in both basic and applied physics. Alternative techniques, such as magnetic spectrometers for charged-particle spectroscopy, while offering better energy resolution, are bulky, expensive, and usually far more difficult to use. Furthermore, they do not directly provide the broad energy-spectrum measurements easily accomplished using semiconductor detectors. Scintillation detectors, which are approximately equivalent to semiconductor detectors in convenience and cost, exhibit 10 to 100 times worse energy resolution. However, their high efficiency and large potential size recommend their use in some measurements

  8. Characteristics of NaI detector in positron imaging device HEADTOME employing circular ring array

    International Nuclear Information System (INIS)

    Miura, Shuichi; Kanno, Iwao; Aizawa, Yasuo; Murakami, Matsutaro; Uemura, Kazuo

    1984-01-01

    In positron emission computed tomographs employing circular ring arrays of detectors, the performance of the imaging device has been specified ultimately by the characteristics of the detector. The responses of NaI detector were studied when detecting positron annihilation photon (511 keV). The study was mainly by using the NaI detector used in hybrid emission computed tomography (CT) ''HEADTOME'' we had developed. A series of measurements were carried out positioning two detectors with 40 cm distance and scanning 22 Na point source in water. Both detectors was inclined from 0 0 through 30 0 to change incident angle of positron annihilation toward crystal face. Energy window was set from 100 to 700 keV. The results were presented as follows; 1 Shortening the crystal length from 7 to 5 cm made sensitivity decrease about 10% and resolution deteriorate about 1 mm (FWHM). 2 As the results of varying the width of the crystal, 20 mm width was optimal at any incident angle. 3 The lead septum between the detectors was the thickness of 4 mm enough to reject multiple detector interactions (crosstalk). 4 Beam mask which was made of lead in order to improve spatial resolution and placed on crystal face worked effectively for incident angles from 0 0 to 15 0 but degraded uniformity of spatial resolution from 0 0 to through 30 0 . (author)

  9. HIBP primary beam detector

    International Nuclear Information System (INIS)

    Schmidt, T.W.

    1979-01-01

    A position measuring detector was fabricated for the Heavy Ion Beam Probe. The 11 cm by 50 cm detector was a combination of 15 detector wires in one direction and 63 copper bars - .635 cm by 10 cm to measure along an orthogonal axis by means of a current divider circuit. High transmission tungsten meshes provide entrance windows and suppress secondary electrons. The detector dimensions were chosen to resolve the beam position to within one beam diameter

  10. First experimental observation of double-photon Compton scattering using single gamma detector

    International Nuclear Information System (INIS)

    Sandhu, B.S.; Saddi, M.B.; Singh, B.; Ghumman, B.S.

    2003-01-01

    Full text: The phenomenon of double-photon Compton scattering has been successfully observed using single gamma detector, a technique avoiding the use of complicated slow-fast coincidence set-up used till now for observing this higher order process. Here doubly differentiated collision cross-section integrated over direction of one of the two final photons, the direction of other one being kept fixed, has been measured experimentally for 0.662 MeV incident gamma photons. The energy spectra of the detected photons are observed as a long tail to the single-photon Compton line on the lower side of the full energy peak in the recorded scattered energy spectrum. The present results are in agreement with theory of this process

  11. The CosmicWatch Desktop Muon Detector: a self-contained, pocket sized particle detector

    Science.gov (United States)

    Axani, S. N.; Frankiewicz, K.; Conrad, J. M.

    2018-03-01

    The CosmicWatch Desktop Muon Detector is a self-contained, hand-held cosmic ray muon detector that is valuable for astro/particle physics research applications and outreach. The material cost of each detector is under 100 and it takes a novice student approximately four hours to build their first detector. The detectors are powered via a USB connection and the data can either be recorded directly to a computer or to a microSD card. Arduino- and Python-based software is provided to operate the detector and an online application to plot the data in real-time. In this paper, we describe the various design features, evaluate the performance, and illustrate the detectors capabilities by providing several example measurements.

  12. Study of charge transport in silicon detectors: Non-irradiated and irradiated

    International Nuclear Information System (INIS)

    Leroy, C.; Roy, P.; Casse, G.; Glaser, M.; Grigoriev, E.; Lemeilleur, F.

    1999-01-01

    The electrical characteristics of silicon detectors (standard planar float zone and MESA detectors) as a function of the particle fluence can be extracted by the application of a model describing the transport of charge carriers generated in the detectors by ionizing particles. The current pulse response induced by α and β particles in non-irradiated detectors and detectors irradiated up to fluences PHI ∼ 3 · 10 14 particles/cm 2 is reproduced via this model: i) by adding a small n-type region 15 μm deep on the p + side for the detectors at fluences beyond the n to p-type inversion and ii) for the MESA detectors, by considering one additional dead layer of 14 μm (observed experimentally) on each side of the detector, and introducing a second (delayed) component to the current pulse response. For both types of detectors, the model gives mobilities decreasing linearily up to fluences of about 5·10 13 particles/cm 2 and converging, beyond, to saturation values of about 1050 cm 2 /Vs and 450 cm 2 /Vs for electrons and holes, respectively. At a fluence PHI ∼ 10 14 particles/cm 2 (corresponding to about ten years of operation at the CERN-LHC), charge collection deficits of about 14% for β particles, 25% for α particles incident on the front and 35% for α particles incident on the back of the detector are found for both type of detectors

  13. Diamond Detector Technology: Status and Perspectives

    CERN Document Server

    Reichmann, M; Artuso, M; Bachmair, F; Bäni, L; Bartosik, M; Beacham, J; Beck, H; Bellini, V; Belyaev, V; Bentele, B; Berdermann, E; Bergonzo, P; Bes, A; Brom, J-M; Bruzzi, M; Cerv, M; Chiodini, G; Chren, D; Cindro, V; Claus, G; Collot, J; Cumalat, J; Dabrowski, A; D'Alessandro, R; Dauvergne, D; de Boer, W; Dorfer, C; Dünser, M; Eremin, V; Eusebi, R; Forcolin, G; Forneris, J; Frais-Kölbl, H; Gallin-Martel, L; Gallin-Martel, M L; Gan, K K; Gastal, M; Giroletti, C; Goffe, M; Goldstein, J; Golubev, A; Gorišek, A; Grigoriev, E; Grosse-Knetter, J; Grummer, A; Gui, B; Guthoff, M; Haughton, I; Hiti, B; Hits, D; Hoeferkamp, M; Hofmann, T; Hosslet, J; Hostachy, J-Y; Hügging, F; Hutton, C; Jansen, H; Janssen, J; Kagan, H; Kanxheri, K; Kasieczka, G; Kass, R; Kassel, F; Kis, M; Konovalov, V; Kramberger, G; Kuleshov, S; Lacoste, A; Lagomarsino, S; Lo Giudice, A; Lukosi, E; Maazouzi, C; Mandic, I; Mathieu, C; Menichelli, M; Mikuž, M; Morozzi, A; Moss, J; Mountain, R; Murphy, S; Muškinja, M; Oh, A; Oliviero, P; Passeri, D; Pernegger, H; Perrino, R; Picollo, F; Pomorski, M; Potenza, R; Quadt, A; Re, A; Riley, G; Roe, S; Sanz-Becerra, D A; Scaringella, M; Schaefer, D; Schmidt, C J; Schnetzer, S; Sciortino, S; Scorzoni, A; Seidel, S; Servoli, L; Smith, S; Sopko, B; Sopko, V; Spagnolo, S; Spanier, S; Stenson, K; Stone, R; Sutera, C; Tannenwald, B; Taylor, A; Traeger, M; Tromson, D; Trischuk, W; Tuve, C; Uplegger, L; Velthuis, J; Venturi, N; Vittone, E; Wagner, S; Wallny, R; Wang, J C; Weingarten, J; Weiss, C; Wengler, T; Wermes, N; Yamouni, M; Zavrtanik, M

    2018-01-01

    The planned upgrade of the LHC to the High-Luminosity-LHC will push the luminosity limits above the original design values. Since the current detectors will not be able to cope with this environment ATLAS and CMS are doing research to find more radiation tolerant technologies for their innermost tracking layers. Chemical Vapour Deposition (CVD) diamond is an excellent candidate for this purpose. Detectors out of this material are already established in the highest irradiation regimes for the beam condition monitors at LHC. The RD42 collaboration is leading an effort to use CVD diamonds also as sensor material for the future tracking detectors. The signal behaviour of highly irradiated diamonds is presented as well as the recent study of the signal dependence on incident particle flux. There is also a recent development towards 3D detectors and especially 3D detectors with a pixel readout based on diamond sensors.

  14. Linearity discontinuities in Xe-filled X-ray microstrip detectors

    DEFF Research Database (Denmark)

    Zavattini, G.; Feroci, M.; Budtz-Jørgensen, Carl

    1997-01-01

    A prototype Xe + 10% CH4 microstrip detector was used to study the K-edge discontinuity in the pulse-height distribution as a function of the energy of incident X-rays. The electronics used was such that a pulse-shape rejection could be made of K-fluorescence reabsorption in the detector. The mea...

  15. Superlattice electroabsorption radiation detector

    International Nuclear Information System (INIS)

    Cooke, B.J.

    1993-06-01

    This paper provides a preliminary investigation of a new class of superlattice electroabsorption radiation detectors that employ direct optical modulation for high-speed, two-dimensional (2-D), high-resolution imaging. Applications for the detector include nuclear radiation measurements, tactical guidance and detection (laser radar), inertial fusion plasma studies, and satellite-based sensors. Initial calculations discussed in this paper indicate that a 1.5-μm (GaAlAs) multi-quantum-well (MQW) Fabry-Perot detector can respond directly to radiation of energies 1 eV to 10 KeV, and indirectly (with scattering targets) up through gamma, with 2-D sample rates on the order of 20 ps

  16. High-energy detector

    Science.gov (United States)

    Bolotnikov, Aleksey E [South Setauket, NY; Camarda, Giuseppe [Farmingville, NY; Cui, Yonggang [Upton, NY; James, Ralph B [Ridge, NY

    2011-11-22

    The preferred embodiments are directed to a high-energy detector that is electrically shielded using an anode, a cathode, and a conducting shield to substantially reduce or eliminate electrically unshielded area. The anode and the cathode are disposed at opposite ends of the detector and the conducting shield substantially surrounds at least a portion of the longitudinal surface of the detector. The conducting shield extends longitudinally to the anode end of the detector and substantially surrounds at least a portion of the detector. Signals read from one or more of the anode, cathode, and conducting shield can be used to determine the number of electrons that are liberated as a result of high-energy particles impinge on the detector. A correction technique can be implemented to correct for liberated electron that become trapped to improve the energy resolution of the high-energy detectors disclosed herein.

  17. Fast CsI-phoswich detector

    International Nuclear Information System (INIS)

    Langenbrunner, J.R.

    1996-01-01

    An improved phoswich radiation detector used pure CsI crystal and a fast plastic scintillator and a single photomultiplier tube. The plastic is arranged to receive incident radiation, and that which passed through then strikes the CsI crystal. Scintillation light from both the plastic and CsI crystal are applied to the photomultiplier tube, with the light from the plastic passing through the crystal without absorption therein. Electronics are provided for analyzing the output of the photomultiplier tube to discriminate responses due to the plastic and the CsI crystal, through short gate and long gate integration, to produce results which are indicative of the characteristics of the different types of incident radiation, even in the presence of large amounts of radiation. The phoswich detector has excellent timing resolution. The scintillators of the CsI- phoswich were chosen for their fast risetimes, of about 3 ns for NE102A, and 30 ns for the pure CsI. 5 figs

  18. New developments in PET detector technology

    International Nuclear Information System (INIS)

    Niu Lingxin; Zhao Shujun; Zhang Bin; Liu Haojia

    2010-01-01

    The researches on PET detector are always active and innovative area. The research direction of PET detector includes improving performances of scintillator-based detectors, investigating new detectors suitable for multi-modality imaging (e.g. PET/CT and PET/MRI), meeting requirements of TOF and DOI technologies and boosting the development of the technologies. In this paper, new developments in PET detector technology about scintillation crystal, photodetector and semiconductor detector is introduced. (authors)

  19. Fast method for geometric calibration of detectors and matching testing between two detectors

    International Nuclear Information System (INIS)

    Pechenova, O.Yu.

    2002-01-01

    A fast method of geometric calibration of detectors has been proposed. The main idea of this method is to determine offsets by fitting the real data distribution by analytic functions which describe the motion of one detector relative to the other one. This method can be applicable to offsets determination for one detector relative to the other detector or for one part of the detector relative to its other part. The detectors should be placed perpendicular to the beam axis. The form of analytic functions depends on the geometry of the experiment and direction of the coordinate axes. The analytic functions have been obtained using the rotation matrices. This method can be applied to the matching testing between two detectors

  20. Linearity of photoconductive GaAs detectors to pulsed electrons

    International Nuclear Information System (INIS)

    Ziegler, L.H.

    1995-01-01

    The response of neutron damaged GaAs photoconductor detectors to intense, fast (50 psec fwhm) pulses of 16 MeV electrons has been measured. Detectors made from neutron damaged GaAs are known to have reduced gain, but significantly improved bandwidth. An empirical relationship between the observed signal and the incident electron fluence has been determined

  1. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors

  2. Development of an imaging VUV monochromator in normal incidence region

    Energy Technology Data Exchange (ETDEWEB)

    Koog, Joong-San

    1996-07-01

    This paper describes a development of the two-dimensional imaging monochromator system. A commercial normal incidence monochromator working on off-Rowland circle mounting is used for this purpose. The imaging is achieved with utilizing the pinhole camera effect created by an entrance slit of limited height. The astigmatism in the normal incidence mounting is small compared with a grazing incidence mount, but has a finite value. The point is that for near normal incidence, the vertical focusing with a concave grating is produced at outside across the exit slit. Therefore, by putting a 2-D detector at the position away from the exit slit ({approx}30 cm), a one-to-one correspondence between the position of a point on the detector and where it originated in the source is accomplished. This paper consists of (1) the principle and development of the imaging monochromator using the off-Rowland mounting, including the 2-D detector system, (2) a computer simulation by ray tracing for investigations of the imaging properties of imaging system, and aberration from the spherical concave grating on the exit slit, (3) the plasma light source (TPD-S) for the test experiments, (4) Performances of the imaging monochromator system on the spatial resolution and sensitivity, and (5) the use of this system for diagnostic studies on the JIPP T-IIU tokamak. (J.P.N.)

  3. Development of an imaging VUV monochromator in normal incidence region

    International Nuclear Information System (INIS)

    Koog, Joong-San.

    1996-07-01

    This paper describes a development of the two-dimensional imaging monochromator system. A commercial normal incidence monochromator working on off-Rowland circle mounting is used for this purpose. The imaging is achieved with utilizing the pinhole camera effect created by an entrance slit of limited height. The astigmatism in the normal incidence mounting is small compared with a grazing incidence mount, but has a finite value. The point is that for near normal incidence, the vertical focusing with a concave grating is produced at outside across the exit slit. Therefore, by putting a 2-D detector at the position away from the exit slit (∼30 cm), a one-to-one correspondence between the position of a point on the detector and where it originated in the source is accomplished. This paper consists of 1) the principle and development of the imaging monochromator using the off-Rowland mounting, including the 2-D detector system, 2) a computer simulation by ray tracing for investigations of the imaging properties of imaging system, and aberration from the spherical concave grating on the exit slit, 3) the plasma light source (TPD-S) for the test experiments, 4) Performances of the imaging monochromator system on the spatial resolution and sensitivity, and 5) the use of this system for diagnostic studies on the JIPP T-IIU tokamak. (J.P.N.)

  4. Performance of low-cost X-ray area detectors with consumer digital cameras

    International Nuclear Information System (INIS)

    Panna, A.; Gomella, A.A.; Harmon, K.J.; Chen, P.; Miao, H.; Bennett, E.E.; Wen, H.

    2015-01-01

    We constructed X-ray detectors using consumer-grade digital cameras coupled to commercial X-ray phosphors. Several detector configurations were tested against the Varian PaxScan 3024M (Varian 3024M) digital flat panel detector. These include consumer cameras (Nikon D800, Nikon D700, and Nikon D3X) coupled to a green emission phosphor in a back-lit, normal incidence geometry, and in a front-lit, oblique incidence geometry. We used the photon transfer method to evaluate detector sensitivity and dark noise, and the edge test method to evaluate their spatial resolution. The essential specifications provided by our evaluation include discrete charge events captured per mm 2 per unit exposure surface dose, dark noise in equivalents of charge events per pixel, and spatial resolution in terms of the full width at half maximum (FWHM) of the detector's line spread function (LSF). Measurements were performed using a tungsten anode X-ray tube at 50 kVp. The results show that the home-built detectors provide better sensitivity and lower noise than the commercial flat panel detector, and some have better spatial resolution. The trade-off is substantially smaller imaging areas. Given their much lower costs, these home-built detectors are attractive options for prototype development of low-dose imaging applications

  5. The data acquisition system for a SPECT with cylindrical detector

    International Nuclear Information System (INIS)

    Jin Yongjie; Liu Yinong; Li Yuanjing

    1995-01-01

    The data acquisition and position estimation system has been developed for a multi-crystal SPECT with modular cylindrical detector. The electronics screen photon energy determines the detector module stricken by incident photon. The relevant PMT outputs are digitized and passed onto a Pentium PC. Then PMT gain normalization, detector bar identification, energy correction, event coordinates calculation and linearity correction are real-time performed by the PC. The system has been employed in clinical brain imaging

  6. A silicon strip detector array for energy verification and quality assurance in heavy ion therapy.

    Science.gov (United States)

    Debrot, Emily; Newall, Matthew; Guatelli, Susanna; Petasecca, Marco; Matsufuji, Naruhiro; Rosenfeld, Anatoly B

    2018-02-01

    The measurement of depth dose profiles for range and energy verification of heavy ion beams is an important aspect of quality assurance procedures for heavy ion therapy facilities. The steep dose gradients in the Bragg peak region of these profiles require the use of detectors with high spatial resolution. The aim of this work is to characterize a one dimensional monolithic silicon detector array called the "serial Dose Magnifying Glass" (sDMG) as an independent ion beam energy and range verification system used for quality assurance conducted for ion beams used in heavy ion therapy. The sDMG detector consists of two linear arrays of 128 silicon sensitive volumes each with an effective size of 2mm × 50μm × 100μm fabricated on a p-type substrate at a pitch of 200 μm along a single axis of detection. The detector was characterized for beam energy and range verification by measuring the response of the detector when irradiated with a 290 MeV/u 12 C ion broad beam incident along the single axis of the detector embedded in a PMMA phantom. The energy of the 12 C ion beam incident on the detector and the residual energy of an ion beam incident on the phantom was determined from the measured Bragg peak position in the sDMG. Ad hoc Monte Carlo simulations of the experimental setup were also performed to give further insight into the detector response. The relative response profiles along the single axis measured with the sDMG detector were found to have good agreement between experiment and simulation with the position of the Bragg peak determined to fall within 0.2 mm or 1.1% of the range in the detector for the two cases. The energy of the beam incident on the detector was found to vary less than 1% between experiment and simulation. The beam energy incident on the phantom was determined to be (280.9 ± 0.8) MeV/u from the experimental and (280.9 ± 0.2) MeV/u from the simulated profiles. These values coincide with the expected energy of 281 MeV/u. The sDMG detector

  7. Omni-directional Particle Detector (ODPD) on Tiangong-2 Spacecraft

    Science.gov (United States)

    Guohong, S.; Zhang, S.; Yang, X.; Wang, C.

    2017-12-01

    Tiangong-2 spacecraft is the second space laboratory independently developed by china after Tiangong-1, which was launched on 15 September 2016. It is also the first real space laboratory in china, which will be used to further validate the space rendezvous and docking technology and to carry out a series of space tests. The spacecraft's orbit is 350km height and 42° inclination. The omni-directional particle detector (ODPD) on Tiangong-2 spacecraft is a new instrument developed by China. Its goal is the anisotropy and energy spectra of space particles on manned space flight orbit. The ODPD measures the energy spectra and pitch angle distributions of high energy electrons and protons. It consists of one electron spectrum telescope, one proton spectrum telescope and sixteen directional flux telescopes. The ODPD is designed to measure the protons spectrum from 2.5MeV to 150MeV, electrons spectrum from 0.2MeV to 1.5MeV, the flux of electrons energy >200keV and protons energy>1.5MeV on 2∏ space, also the ODPD has a small sensor to measure the LET spectrum from 1-100MeV/cm2sr. The primary advantage can give the particle's pitch angle distributions at any time because of the sixteen flux telescopes arrange form 0 to 180 degree. This is the first paper dealing with ODPD data, so we firstly spend some time describing the instrument, its theory of operation and its calibration. Then we give the preliminary detecting results.

  8. Study on Silicon detectors

    International Nuclear Information System (INIS)

    Gervino, G.; Boero, M.; Manfredotti, C.; Icardi, M.; Gabutti, A.; Bagnolatti, E.; Monticone, E.

    1990-01-01

    Prototypes of Silicon microstrip detectors and Silicon large area detectors (3x2 cm 2 ), realized directly by our group, either by ion implantation or by diffusion are presented. The physical detector characteristics and their performances determined by exposing them to different radioactive sources and the results of extensive tests on passivation, where new technological ways have been investigated, are discussed. The calculation of the different terms contributing to the total dark current is reported

  9. X-Ray and Gamma-Ray Radiation Detector

    DEFF Research Database (Denmark)

    2015-01-01

    Disclosed is a semiconductor radiation detector for detecting X-ray and / or gamma-ray radiation. The detector comprises a converter element for converting incident X-ray and gamma-ray photons into electron-hole pairs, at least one cathode, a plurality of detector electrodes arranged with a pitch...... (P) along a first axis, a plurality of drift electrodes, a readout circuitry being configured to read out signals from the plurality of detector electrodes and a processing unit connected to the readout circuitry and being configured to detect an event in the converter element. The readout circuitry...... is further configured to read out signals from the plurality of drift electrodes, and the processing unit is further configured to estimate a location of the event along the first axis by processing signals obtained from both the detector electrodes and the drift electrodes, the location of the event along...

  10. Method and apparatus for sensing a desired component of an incident magnetic field using magneto resistive elements biased in different directions

    Science.gov (United States)

    Pant, Bharat B. (Inventor); Wan, Hong (Inventor)

    1999-01-01

    A method and apparatus for sensing a desired component of a magnetic field using an isotropic magnetoresistive material. This is preferably accomplished by providing a bias field that is parallel to the desired component of the applied magnetic field. The bias field is applied in a first direction relative to a first set of magnetoresistive sensor elements, and in an opposite direction relative to a second set of magnetoresistive sensor elements. In this configuration, the desired component of the incident magnetic field adds to the bias field incident on the first set of magnetoresistive sensor elements, and subtracts from the bias field incident on the second set of magnetoresistive sensor elements. The magnetic field sensor may then sense the desired component of the incident magnetic field by simply sensing the difference in resistance of the first set of magnetoresistive sensor elements and the second set of magnetoresistive sensor elements.

  11. Direct observation and measurements of neutron induced deep levels responsible for N{sub eff} changes in high resistivity silicon detectors using TCT

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.; Li, C.J. [Brookhaven National Lab., Upton, NY (United States); Eremin, V.; Verbitskaya, E. [AN SSSR, Leningrad (Russian Federation). Fiziko-Tekhnicheskij Inst.

    1996-03-01

    Neutron induced deep levels responsible for changes of space charge concentration {ital N{sub eff}} in high resistivity silicon detectors have been observed directly using the transient current technique (TCT). It has been observed by TCT that the absolute value and sign of {ital N{sub eff}} experience changes due to the trapping of non- equilibrium free carriers generated near the surface (about 5 micrometers depth into the silicon) by short wavelength laser pulses in fully depleted detectors. Electron trapping causes {ital N{sub eff}} to change toward negative direction (or more acceptor-like space charges) and hole trapping causes {ital N{sub eff}} to change toward positive direction (or more donor-like space charges). The specific temperature associated with these {ital N{sub eff}} changes are those of the frozen-up temperatures for carrier emission of the corresponding deep levels. The carrier capture cross sections of various deep levels have been measured directly using different free carrier injection schemes. 10 refs., 12 figs., 3 tabs.

  12. MUON DETECTORS: DT

    CERN Document Server

    M. Dallavalle.

    The DT system is ready for the LHC start up. The status of detector hardware, control and safety, of the software for calibration and monitoring and of people has been reviewed at several meetings, starting with the CMS Action Matrix Review and with the Muon Barrel Workshop (October 5 to 7). The disconnected HV channels are at a level of about 0.1%. The loss in detector acceptance because of failures in the Read-Out and Trigger electronics is about 0.5%. The electronics failure rate has been lower this year: next year will tell us whether the rate has stabilised and hopefully will confirm that the number of spares is adequate for ten years operation. Although the detector safety control is very accurate and robust, incidents have happened. In particular the DT system suffered from a significant water leak, originated in the top part of YE+1, that generated HV trips in eighteen chambers going transversely down from the top sector in YB+2 to the bottom sector in YB-2. All chambers recovered and all t...

  13. Calorimetric low-temperature detectors on semiconductor base for the energy-resolving detection of heavy ions

    International Nuclear Information System (INIS)

    Kienlin, A. von.

    1994-01-01

    In the framework of this thesis for the first time calorimetric low-temperature detectors for the energy-resolving detection of heavy ions were developed and successfully applied. Constructed were two different detector types, which work both with a semiconductor thermistor. The temperature increasement effected by a particle incidence is read out. In the first detector type the thermistor was simutaneously used as absorber. The thickness of the germanium crystals was sufficient in order to stop the studied heavy ions completely. In the second type, a composed calorimeter, a sapphire crystal, which was glued on a germanium thermistor, served as absorber for the incident heavy ions. The working point of the calorimeter lies in the temperature range (1.2-4.2 K), which is reachable with a pumped 4 He cryostat. The temperatur increasement of the calorimeter amounts after the incidence of a single α particle about 20-30 μK and that after a heavy ion incidence up to some mK. An absolute energy resolution of 400-500 keV was reached. In nine beam times the calorimeters were irradiated by heavy ions ( 20 Ne, 40 Ar, 136 Xe, 208 Pb, 209 Bi) of different energies (3.6 MeV/nucleon< E<12.5 MeV/nucleon) elastically scattered from gold foils. In the pulse height spectra of the first detector type relatively broad, complex-structurated line shapes were observed. By systematic measurements dependences of the complex line structures on operational parameters of the detector, the detector temperature, and the position of the incident particle could be detected. Together with the results of further experiments a possible interpretation of these phenomena is presented. Contrarily to the complex line structures of the pure germanium thermistor the line shapes in the pulse height spectra, which were taken up in a composite germanium/sapphire calorimeter, are narrow and Gauss-shaped

  14. The LHC detector challenge

    CERN Document Server

    Virdee, Tejinder S

    2004-01-01

    The Large Hadron Collider (LHC) from CERN, scheduled to come online in 2007, is a multi-TeV proton-proton collider with vast detectors. Two of the more significant detectors for LHC are ATLAS and CMS. Currently, both detectors are more than 65% complete in terms of financial commitment, and the experiments are being assembled at an increasing pace. ATLAS is being built directly in its underground cavern, whereas CMS is being assembled above ground. When completed, both detectors will aid researchers in determining what lies at the high-energy frontier, in particular the mechanism by which particles attain mass. (Edited abstract).

  15. Neutron detectors for nuclear reactor control

    International Nuclear Information System (INIS)

    Duchene, Jean; Verdant, Robert.

    1974-01-01

    In view of the importance of in-core measurements the distinction is made between detectors used outside and inside the core. In the former case proportional counters, fission chambers and boron chambers are reviewed in turn. The only in-core detectors considered are those giving a direct measurement, i.e. supplying an electric signal representative of the neutron fluence rate while in the measurement position at the point given. Two kinds of detectors are used for direct measurements: miniature fission chambers and collectors, known also as neutron-electron converters [fr

  16. Cherenkov water detector NEVOD

    Science.gov (United States)

    Petrukhin, A. A.

    2015-05-01

    A unique multipurpose Cherenkov water detector, the NEVOD facility, uses quasispherical measuring modules to explore all the basic components of cosmic rays on Earth's surface, including neutrinos. Currently, the experimental complex includes the Cherenkov water detector, a calibration telescope system, and a coordinate detector. This paper traces the basic development stages of NEVOD, examines research directions, presents the results obtained, including the search for the solution to the 'muon puzzle', and discusses possible future development prospects.

  17. Direct Dark Matter Detection through the use of a Xenon Based TPC Detector

    Science.gov (United States)

    Daniel, Jonathan; Akerib, Daniel; LZ group at SLAC

    2018-01-01

    The vast majority of matter in the universe is unaccounted for. Only 15% of the universe's mass density is visible matter, while the other 85% is Dark Matter (DM). The Weakly Interacting Massive Particle (WIMP) is currently the frontrunner of the DM candidates. The Large Underground Xenon (LUX) and next generation LUX-ZEPLIN (LZ) experiments are designed to directly detect WIMPs. Both experiments are xenon-based Time Projection Chambers (TPC) used to observe possible WIMP interactions. These interactions produce photons and electrons with the photons being collected in a set of two photomultiplier tube (PMT) arrays and the electrons drifted upwards in the detector by a strong electric field to create a secondary production of photons in gaseous xenon. These two populations of photons are classified as S1 and S2 signals, respectively. Using these signals we reconstruct the energy and position of the interaction and in doing so we can eliminate background events that would otherwise “light up” the detector. My participation in the experiment, while at SLAC, was the creation of the grids that produce the large electric field, along with additional lab activities aimed at testing the grids. While at Stan State, I work on background modeling in order to distinguish a possible WIMP signal from ambient backgrounds.

  18. The H1 detector

    International Nuclear Information System (INIS)

    Cozzika, G.

    1992-11-01

    The H1 detector presently operating at the HERA e-p collider is described. A general overview of the detector is given with particular emphasis on the calorimeters, the main element of which is a liquid Argon calorimeter enclosed within a large radius solenoid. Calorimetry in the proton direction, close to the beam-pipe is provided by a copper-silicon pad hadronic calorimeter. In the electron direction a lead-scintillator electromagnetic calorimeter closes the solid angle between the rear part of the liquid Argon calorimeter and the beam-pipe. An iron limited streamer tube tail catcher using the return yoke of the solenoid as absorber completes the calorimetry of the detector. The hardware triggers derived from the calorimeters are also described and some performance details of the calorimeters are given

  19. Adjustment of a low energy, X-rays generator (6 kV - 50 mA). Application to X-rays detectors calibration

    International Nuclear Information System (INIS)

    Legistre, C.

    1995-02-01

    The aim of this memoir is the calibration of an aluminium photocathode X-rays photoelectric detector, in the spectral range 0,5 keV - 1,5 KeV, with a continuous X-ray source. The detectors's calibration consist to measure the detector's sensitivity versus incident energy. In order to produce monochromatic incident beam on the detector, we used a multilayer mirror whose reflectivity was characterized. The measurements are compared to those realized in an other laboratory. (authors). 36 refs., 61 figs., 13 tabs., 2 photos

  20. Directional detection of dark matter with two-dimensional targets

    Science.gov (United States)

    Hochberg, Yonit; Kahn, Yonatan; Lisanti, Mariangela; Tully, Christopher G.; Zurek, Kathryn M.

    2017-09-01

    We propose two-dimensional materials as targets for direct detection of dark matter. Using graphene as an example, we focus on the case where dark matter scattering deposits sufficient energy on a valence-band electron to eject it from the target. We show that the sensitivity of graphene to dark matter of MeV to GeV mass can be comparable, for similar exposure and background levels, to that of semiconductor targets such as silicon and germanium. Moreover, a two-dimensional target is an excellent directional detector, as the ejected electron retains information about the angular dependence of the incident dark matter particle. This proposal can be implemented by the PTOLEMY experiment, presenting for the first time an opportunity for directional detection of sub-GeV dark matter.

  1. Higher Serum Direct Bilirubin Levels Were Associated with a Lower Risk of Incident Chronic Kidney Disease in Middle Aged Korean Men

    Science.gov (United States)

    Ryu, Seungho; Chang, Yoosoo; Zhang, Yiyi; Woo, Hee-Yeon; Kwon, Min-Jung; Park, Hyosoon; Lee, Kyu-Beck; Son, Hee Jung; Cho, Juhee; Guallar, Eliseo

    2014-01-01

    Background The association between serum bilirubin levels and incident chronic kidney disease (CKD) in the general population is unknown. We aimed to examine the association between serum bilirubin concentration (total, direct, and indirect) and the risk of incident CKD. Methods and Findings Longitudinal cohort study of 12,823 Korean male workers 30 to 59 years old without CKD or proteinuria at baseline participating in medical health checkup program in a large worksite. Study participants were followed for incident CKD from 2002 through 2011. Estimated glomerular filtration rate (eGFR) was estimated by using the CKD-EPI equation. CKD was defined as eGFR bilirubin were 0.93 (95% CI 0.67–1.28), 0.88 (0.60–1.27) and 0.60 (0.42–0.88), respectively. In multivariable models, the adjusted hazard ratio for CKD comparing the highest to the lowest quartile of serum direct bilirubin levels was 0.60 (95% CI 0.41–0.87; P trend = 0.01). Neither serum total nor indirect bilirubin levels were significantly associated with the incidence of CKD. Conclusions Higher serum direct bilirubin levels were significantly associated with a lower risk of developing CKD, even adjusting for a variety of cardiometabolic parameters. Further research is needed to elucidate the mechanisms underlying this association and to establish the role of serum direct bilirubin as a marker for CKD risk. PMID:24586219

  2. Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

    Energy Technology Data Exchange (ETDEWEB)

    Postovarova, Daria; Evsenin, Alexey; Gorshkov, Igor; Kuznetsov, Andrey; Osetrov, Oleg; Vakhtin, Dmitry; Yurmanov, Pavel [V.G. Khlopin Radium Institute, 194021, 28, 2nd Murinsky pr., Saint-Petersburg (Russian Federation)

    2011-12-13

    A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

  3. Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

    International Nuclear Information System (INIS)

    Postovarova, Daria; Evsenin, Alexey; Gorshkov, Igor; Kuznetsov, Andrey; Osetrov, Oleg; Vakhtin, Dmitry; Yurmanov, Pavel

    2011-01-01

    A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

  4. Segmented focal plane detector for light and heavy ions

    International Nuclear Information System (INIS)

    Wolfs, F.L.H.; Bryan, D.C.; Kurz, K.L.; Herrick, D.M.; Perera, P.A.A.; White, C.A.

    1992-01-01

    A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.)

  5. Multiple scattering in grazing-incidence X-ray diffraction: impact on lattice-constant determination in thin films

    Energy Technology Data Exchange (ETDEWEB)

    Resel, Roland, E-mail: roland.resel@tugraz.at; Bainschab, Markus; Pichler, Alexander [Graz University of Technology, Graz (Austria); Dingemans, Theo [Delft University of Technology, Delft (Netherlands); Simbrunner, Clemens [Johannes Kepler University, Linz (Austria); University of Bremen, Bremen (Germany); Stangl, Julian [Johannes Kepler University, Linz (Austria); Salzmann, Ingo [Humboldt University, Berlin (Germany)

    2016-04-20

    The use of grazing-incidence X-ray diffraction to determine the crystal structure from thin films requires accurate positions of Bragg peaks. Refraction effects and multiple scattering events have to be corrected or minimized. Dynamical scattering effects are observed in grazing-incidence X-ray diffraction experiments using an organic thin film of 2,2′:6′,2′′-ternaphthalene grown on oxidized silicon as substrate. Here, a splitting of all Bragg peaks in the out-of-plane direction (z-direction) has been observed, the magnitude of which depends both on the incidence angle of the primary beam and the out-of-plane angle of the scattered beam. The incident angle was varied between 0.09° and 0.25° for synchrotron radiation of 10.5 keV. This study reveals comparable intensities of the split peaks with a maximum for incidence angles close to the critical angle of total external reflection of the substrate. This observation is rationalized by two different scattering pathways resulting in diffraction peaks at different positions at the detector. In order to minimize the splitting, the data suggest either using incident angles well below the critical angle of total reflection or angles well above, which sufficiently attenuates the contributions from the second scattering path. This study highlights that the refraction of X-rays in (organic) thin films has to be corrected accordingly to allow for the determination of peak positions with sufficient accuracy. Based thereon, a reliable determination of the lattice constants becomes feasible, which is required for crystallographic structure solutions from thin films.

  6. Evaluation of K x-ray escape and crosstalk in CdTe detectors and multi-channel detectors

    International Nuclear Information System (INIS)

    Ohtsuchi, Tetsuro; Ohmori, Koichi; Tsutsui, Hiroshi; Baba, Sueki

    1995-01-01

    The simple structure of CdTe semiconductor detectors facilitates their downsizing, and their possible application to radiographic sensors has been studied. The escape of K X-rays from these detectors increases with reduction of their dimensions and affects the measurements of X- and gamma-ray spectra. K X-rays also produce crosstalk in multi-channel detectors with adjacent channels. Therefore, K X-rays which escape from the detector elements degrade both the precision of energy spectra and spatial resolution. The ratios of escape peak integrated counts to total photon counts for various sizes of CdTe single detectors were calculated for gamma rays using the Monte Carlo method. Also, escape and crosstalk ratios were simulated for the CdTe multi-channel detectors. The theoretical results were tested experimentally for 59.54-keV gamma rays from a 241 Am radioactive source. Results showed that escape ratios for single detectors were strongly dependent on element size and thickness. The escape and crosstalk ratios increased with closer channel pitch. The calculated results showed a good agreement with the experimental data. The calculations made it clear that K X-rays which escaped to neighboring channels induced crosstalk more frequently at smaller channel pitch in multichannel detectors. A radiation shielding grid which blocked incident photons between the boundary channels was also tested by experiment and by calculation. It was effective in reducing the probability of escape and crosstalk

  7. Possibility of gravitational wave detector production on the base of light diffraction

    International Nuclear Information System (INIS)

    Segizboev, T.I.

    1989-01-01

    Gravitational wave detector based on the light diffraction is proposed. Under the gravitation wave incidence on an elastic rod standing acoustic oscillations are excited in it, which are then used as a diffraction grating for the light scattering. A detailed mathematical analysis of this detector is given. 1 ref

  8. Radiation damage in silicon detectors

    CERN Document Server

    Lindström, G

    2003-01-01

    Radiation damage effects in silicon detectors under severe hadron and gamma-irradiation are surveyed, focusing on bulk effects. Both macroscopic detector properties (reverse current, depletion voltage and charge collection) as also the underlying microscopic defect generation are covered. Basic results are taken from the work done in the CERN-RD48 (ROSE) collaboration updated by results of recent work. Preliminary studies on the use of dimerized float zone and Czochralski silicon as detector material show possible benefits. An essential progress in the understanding of the radiation-induced detector deterioration had recently been achieved in gamma irradiation, directly correlating defect analysis data with the macroscopic detector performance.

  9. Peak-to-valley ratios for three different HPGe detectors for the assessment of 137Cs deposition on the ground and the impact of the detector field-of-view.

    Science.gov (United States)

    Östlund, Karl; Samuelsson, Christer; Mattsson, Sören; Rääf, Christopher L

    2017-02-01

    The peak-to-valley (PTV) method was investigated experimentally comparing PTV ratios for three HPGe detectors, with complementary Monte Carlo simulations of scatter in air for larger source-detector distances. The measured PTV ratios for 137Cs in air were similar for three different detectors for incident angles between 0 and 90°. The study indicated that the PTV method can differentiate between surface and shallow depth sources if the detector field of view is limited to a radius of less than 3.5m. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Comparison of Experiment and Simulation of the triple GEM-Based Fast Neutron Detector

    International Nuclear Information System (INIS)

    Wang Xiao-Dong; Luo Wen; Zhang Jun-Wei; Yang He-Run; Duan Li-Min; Lu Chen-Gui; Hu Rong-Jiang; Hu Bi-Tao; Zhang Chun-Hui; Yang Lei; Zhou Jian-Rong; An Lv-Xing

    2015-01-01

    A detector for fast neutrons based on a 10 × 10 cm"2 triple gas electron multiplier (GEM) device is developed and tested. A neutron converter, which is a high density polyethylene (HDPE) layer, is combined with the triple GEM detector cathode and placed inside the detector, in the path of the incident neutrons. The detector is tested by obtaining the energy deposition spectrum with an Am Be neutron source in the Institute of Modern Physics (IMP) at Lanzhou. In the present work we report the results of the tests and compare them with those of simulations. The transport of fast neutrons and their interactions with the different materials in the detector are simulated with the GEANT4 code, to understand the experimental results. The detector displays a clear response to the incident fast neutrons. However, an unexpected disagreement in the energy dependence of the response between the simulated and measured spectra is observed. The neutron sources used in our simulation include deuterium-tritium (DT, 14 MeV), deuterium-deuterium (DD, 2.45 MeV), and Am Be sources. The simulation results also show that among the secondary particles generated by the incident neutron, the main contributions to the total energy deposition are from recoil protons induced in hydrogen-rich HDPE or Kapton (GEM material), and activation photons induced by neutron interaction with Ar atoms. Their contributions account for 90% of the total energy deposition. In addition, the dependence of neutron deposited energy spectrum on the composition of the gas mixture is presented. (paper)

  11. Design, calibration, and performance of the MINERvA detector

    Energy Technology Data Exchange (ETDEWEB)

    Aliaga, L. [Department of Physics, College of William and Mary, Williamsburg, VA 23187 (United States); Sección Física, Departamento de Ciencias, Pontificia Universidad Católica del Perú, Apartado 1761, Lima, Perú (Peru); Bagby, L.; Baldin, B. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Baumbaugh, A. [Sección Física, Departamento de Ciencias, Pontificia Universidad Católica del Perú, Apartado 1761, Lima, Perú (Peru); Bodek, A.; Bradford, R. [University of Rochester, Rochester, NY 14610 (United States); Brooks, W.K. [Departamento de Física, Universidad Técnica Federico Santa María, Avda. España 1680, Casilla 110-V, Valparaíso (Chile); Boehnlein, D. [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Boyd, S. [Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Budd, H. [University of Rochester, Rochester, NY 14610 (United States); Butkevich, A. [Institute for Nuclear Research of the Russian Academy of Sciences, 117312 Moscow (Russian Federation); Martinez Caicedo, D.A.; Castromonte, C.M. [Hampton University, Department of Physics, Hampton, VA 23668 (United States); Christy, M.E. [Department of Physics, University of Minnesota – Duluth, Duluth, MN 55812 (United States); Chvojka, J. [University of Rochester, Rochester, NY 14610 (United States); Motta, H. da [Centro Brasileiro de Pesquisas Físicas, Rua Dr. Xavier Sigaud 150, Urca, Rio de Janeiro, RJ 22290-180 (Brazil); and others

    2014-04-11

    The MINERvA experiment is designed to perform precision studies of neutrino-nucleus scattering using ν{sub μ} and ν{sup ¯}{sub μ} neutrinos incident at 1–20 GeV in the NuMI beam at Fermilab. This article presents a detailed description of the MINERvA detector and describes the ex situ and in situ techniques employed to characterize the detector and monitor its performance. The detector is composed of a finely segmented scintillator-based inner tracking region surrounded by electromagnetic and hadronic sampling calorimetry. The upstream portion of the detector includes planes of graphite, iron and lead interleaved between tracking planes to facilitate the study of nuclear effects in neutrino interactions. Observations concerning the detector response over sustained periods of running are reported. The detector design and methods of operation have relevance to future neutrino experiments in which segmented scintillator tracking is utilized.

  12. Direction of catheter insertion and the incidence of paresthesia during continuous epidural anesthesia in the elderly patients

    Science.gov (United States)

    Kim, Jong-Hak; Lee, Jun Seop

    2013-01-01

    Background Continuous epidural anesthesia is useful for endoscopic urologic surgery, as mostly performed in the elderly patients. In such a case, it is necessary to obtain successful sacral anesthesia, and the insertion of epidural catheter in the caudad direction may be needed. However, continuous epidural catherization has been related to paresthesias. This study aimed to evaluate the effects of the direction of the catheter insertion on the incidence of paresthesias in the elderly patients. Methods Two hundred elderly patients scheduled for endoscopic urologic surgery were enrolled. The epidural catheter was inserted at L2-3, L3-4, and L4-5 using the Tuohy needle. In Group I (n = 100), the Tuohy needle with the bevel directed the cephalad during the catheter insertion. In Group II (n = 100), it directed the caudad. During the catheter insertion, an anesthesiologist evaluated the presence of paresthesias and the ease or difficulty during the catheter insertion. Results In Group I (n = 97), 15.5% of the patients had paresthesias versus 18.4% in Group II (n = 98), and there was no significant difference between the two groups. In paresthesia depending on the insertion site and the ease or difficulty during the catheter insertion, there were no significant differences between the two groups. Conclusions Our results concluded that the direction of epidural catheter insertion did not significantly influence the incidence of paresthesias in the elderly patients. PMID:23741568

  13. A high energy photon detector system in compact form

    International Nuclear Information System (INIS)

    Kato, Sadayuki; Sugano, Katsuhito; Yoshioka, Masakazu.

    1975-01-01

    The development of a high energy photon detector system in compact form for use in experiments of high energy physics is described, and the results of its characteristics calibrated using converted electron beams and a pair spectrometer are reported. This system consists of a total absorption lead glass Cerenkov counter, twenty hodoscope arrays for the vertical and the horizontal directions respectively, a lead plate for the conversion of γ-rays into electron-positron pairs, veto counters, photon hardener, and lead blocks for shieldings and collimation. The spatial resolution of the hodoscope is 15 mm for each direction, covering 301 x 301 mm 2 area. The energy resolution of the total absorption lead glass Cerenkov counter, whose volume is 30 x 30 x 30 cm 3 , is typically 18 % (FWHM) for the incident electron energy of 500 MeV, and it can be expressed with a relation of ΔE/E = 3.94 Esup(-1/2). (E in MeV). (auth.)

  14. Sensitivity determination of CR-39 from Normal and inclined incidence

    International Nuclear Information System (INIS)

    Abou, A.A.; El-Kheir, A.A.; Daas, A.F.; Awwad, Z.; Reda, A.M.

    2000-01-01

    An experimental study have been carried out on alpha- particle track opening (Major and minor axes) using alpha-particles of different energies incident with different angels in addition to the normal incidence. The sensitivity of CR-39 in present work is determined for each of normal and inclined incidence. The results indicated a difference in the sensitivity according to angle of incidence. The variation of alpha- particle tracks (major and minor axes) are calculated and compared with our measured values. Also, it is found that the sensitivity of CR-39 detector is change due to the storage time at room temperature

  15. Experimental characterization of a direct conversion amorphous selenium detector with thicker conversion layer for dual-energy contrast-enhanced breast imaging.

    Science.gov (United States)

    Scaduto, David A; Tousignant, Olivier; Zhao, Wei

    2017-08-01

    Dual-energy contrast-enhanced imaging is being investigated as a tool to identify and localize angiogenesis in the breast, a possible indicator of malignant tumors. This imaging technique requires that x-ray images are acquired at energies above the k-shell binding energy of an appropriate radiocontrast agent. Iodinated contrast agents are commonly used for vascular imaging, and require x-ray energies greater than 33 keV. Conventional direct conversion amorphous selenium (a-Se) flat-panel imagers for digital mammography show suboptimal absorption efficiencies at these higher energies. We use spatial-frequency domain image quality metrics to evaluate the performance of a prototype direct conversion flat-panel imager with a thicker a-Se layer, specifically fabricated for dual-energy contrast-enhanced breast imaging. Imaging performance was evaluated in a prototype digital breast tomosynthesis (DBT) system. The spatial resolution, noise characteristics, detective quantum efficiency, and temporal performance of the detector were evaluated for dual-energy imaging for both conventional full-field digital mammography (FFDM) and DBT. The zero-frequency detective quantum efficiency of the prototype detector is improved by approximately 20% over the conventional detector for higher energy beams required for imaging with iodinated contrast agents. The effect of oblique entry of x-rays on spatial resolution does increase with increasing photoconductor thickness, specifically for the most oblique views of a DBT scan. Degradation of spatial resolution due to focal spot motion was also observed. Temporal performance was found to be comparable to conventional mammographic detectors. Increasing the a-Se thickness in direct conversion flat-panel imagers results in better performance for dual-energy contrast-enhanced breast imaging. The reduction in spatial resolution due to oblique entry of x-rays is appreciable in the most extreme clinically relevant cases, but may not profoundly

  16. A counting silicon microstrip detector for precision compton polarimetry

    CERN Document Server

    Doll, D W; Hillert, W; Krüger, H; Stammschroer, K; Wermes, N

    2002-01-01

    A detector for the detection of laser photons backscattered off an incident high-energy electron beam for precision Compton polarimetry in the 3.5 GeV electron stretcher ring ELSA at Bonn University has been developed using individual photon counting. The photon counting detector is based on a silicon microstrip detector system using dedicated ASIC chips. The produced hits by the pair converted Compton photons are accumulated rather than individually read out. A transverse profile displacement can be measured with mu m accuracy rendering a polarization measurement of the order of 1% on the time scale of 10-15 min possible.

  17. A novel approach for modelling the cluster detector and the SPI ...

    Indian Academy of Sciences (India)

    detectors and for performing experimental studies with the SPI spectrometer for high-energy γ -rays. Keywords. ... corresponds to the complete absorption of incident γ energy and gets contributions from. Pramana – J. Phys. ..... For a γ-ray of energy Eγ , let us first define the ratio of the single-detector hit events to the total full ...

  18. Si(Li) detector system for application to x-ray astronomy rocket experiments

    International Nuclear Information System (INIS)

    Griffiths, R.E.; Cheron, C.; Friant, A.; Jehanno, C.; Rocchia, R.; Rothenflug, R.; Testard, O.

    1975-01-01

    The problems associated with the use of Si(Li) detectors in x-ray astronomy rocket experiments are discussed. In particular a detector system is described that can be used at the focus of a grazing-incidence paraboloid telescope for the energy range 0.3 to 2 keV. (U.S.)

  19. Spectrum, time structure and direction of incidence of the August 16, 1976 gamma ray burst

    International Nuclear Information System (INIS)

    Sommer, H.; Mueller, D.; Horstman, H.; Bassani, L.

    1977-01-01

    Two major bursts of energetic photons have been recorded with a new balloon-borne instrument during the second transatlantic flight in 1976: One in coincidence with a type III solar radio burst on August 16 and a very energetic gamma ray burst of non-solar origin starting at 16:15.5 UT of August 16. Spectral information of the gamma ray burst has been obtained up to 2 MeV. A crude position of the burst source has been derived from data of a directional detector array after correcting for absorption and scattering in the earth's atmosphere. (author)

  20. He Puff System For Dust Detector Upgrade

    International Nuclear Information System (INIS)

    Rais, B.; Skinner, C.H.; Roquemore, A.L.

    2010-01-01

    Local detection of surface dust is needed for the safe operation of next-step magnetic fusion devices such as ITER. An electrostatic dust detector, based on a 5 cm x 5 cm grid of interlocking circuit traces biased to 50 V, has been developed to detect dust on remote surfaces and was successfully tested for the first time on the National Spherical Torus Experiment (NSTX). We report on a helium puff system that clears residual dust from this detector and any incident debris or fibers that might cause a permanent short circuit. The entire surface of the detector was cleared of carbon particles by two consecutive helium puffs delivered by three nozzles of 0.45 mm inside diameter. The optimal configuration was found to be with the nozzles at an angle of 30o with respect to the surface of the detector and a helium backing pressure of 6 bar.

  1. New thermal neutron solid-state electronic detector based on HgI2 crystals

    International Nuclear Information System (INIS)

    Melamud, M.; Burshtein, Z.

    1983-07-01

    We describe the development of a new solid-state electronic neutron detector, based on HgI 2 single crystals. Incident neutrons are absorbed in high neutron absorbing foils, such as cadmium or gadolinium, which are placed in front of a HgI 2 detector. Gamma rays, emitted as a result of the neutron absorbtion, are then absorbed in the HgI 2 , generating free charge carriers, which are collected by the electric field. The advantage of this system lies in it's manufacturing simplicity, low weight and small physical dimensions, compared to gas-filled conventional neutron detectors. The disadvantage is that the system does not discriminate between gamma rays and neutrons. A method to minimize this disadvantage is pointed out. It is as well possible to count neutrons by direct exposure of the HgI 2 to neutrons. The neutron-to-gamma transformation in that case takes place by the material nuclei themselves. This method, however, is impractical due to the interference of delayed radioactivity whose origin are 129 I nuclei. They are generated from 128 I by absorbing a neutron, and decay with a 25 min half lifetime involving gamma emissions. (author)

  2. Spatial resolution in Micromegas detectors

    CERN Document Server

    Bayb, A; Giomataris, Ioanis; Zaccone, Henri; Bay, A; Perroud, Jean-Pierre; Ronga, F

    2001-01-01

    The performance of a telescope of Micromegas detectors has been studied in a pion beam at the CERN PS. With a gas filling of CF/sub 4 / and 20% isobutane and with a strip pitch of 100 mu m an accuracy of 14+or-3 mu m on the spatial resolution has been measured at normal incidence. A simulation demonstrates that the resolution is limited by the size of the holes of the mesh of the detector and could be reduced to 11 mu m in the same conditions with smaller holes. Even further improvement down to 8.5 mu m is feasible for the same gas with an optimized 75 mu m strip pitch. (5 refs).

  3. Compound Semiconductor Radiation Detector

    International Nuclear Information System (INIS)

    Kim, Y. K.; Park, S. H.; Lee, W. G.; Ha, J. H.

    2005-01-01

    In 1945, Van Heerden measured α, β and γ radiations with the cooled AgCl crystal. It was the first radiation measurement using the compound semiconductor detector. Since then the compound semiconductor has been extensively studied as radiation detector. Generally the radiation detector can be divided into the gas detector, the scintillator and the semiconductor detector. The semiconductor detector has good points comparing to other radiation detectors. Since the density of the semiconductor detector is higher than that of the gas detector, the semiconductor detector can be made with the compact size to measure the high energy radiation. In the scintillator, the radiation is measured with the two-step process. That is, the radiation is converted into the photons, which are changed into electrons by a photo-detector, inside the scintillator. However in the semiconductor radiation detector, the radiation is measured only with the one-step process. The electron-hole pairs are generated from the radiation interaction inside the semiconductor detector, and these electrons and charged ions are directly collected to get the signal. The energy resolution of the semiconductor detector is generally better than that of the scintillator. At present, the commonly used semiconductors as the radiation detector are Si and Ge. However, these semiconductor detectors have weak points. That is, one needs thick material to measure the high energy radiation because of the relatively low atomic number of the composite material. In Ge case, the dark current of the detector is large at room temperature because of the small band-gap energy. Recently the compound semiconductor detectors have been extensively studied to overcome these problems. In this paper, we will briefly summarize the recent research topics about the compound semiconductor detector. We will introduce the research activities of our group, too

  4. Radiation and Background Levels in a CLIC Detector due to Beam-Beam Effects Optimisation of Detector Geometries and Technologies

    CERN Document Server

    Sailer, André; Lohse, Thomas

    2013-01-10

    The high charge density---due to small beam sizes---and the high energy of the proposed CLIC concept for a linear electron--positron collider with a centre-of-mass energy of up to 3~TeV lead to the production of a large number of particles through beam-beam interactions at the interaction point during every bunch crossing (BX). A large fraction of these particles safely leaves the detector. A still significant amount of energy will be deposited in the forward region nonetheless, which will produce secondary particles able to cause background in the detector. Furthermore, some particles will be created with large polar angles and directly cause background in the tracking detectors and calorimeters. The main sources of background in the detector, either directly or indirectly, are the incoherent $mathrm{e}^{+}mathrm{e}^{-}$ pairs and the particles from $gammagamma ightarrow$ hadron events. The background and radiation levels in the detector have to be estimated, to study if a detector is feasible, that can han...

  5. Characterization of an in-vacuum PILATUS 1M detector.

    Science.gov (United States)

    Wernecke, Jan; Gollwitzer, Christian; Müller, Peter; Krumrey, Michael

    2014-05-01

    A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small-angle X-ray scattering (SAXS) experiments and anomalous SAXS at absorption edges of light elements. The radiometric and geometric properties of the detector such as quantum efficiency, pixel pitch and module alignment have been determined with low uncertainties. The first grazing-incidence SAXS results demonstrate the superior resolution in momentum transfer achievable at low photon energies.

  6. Comparison of imaging properties of direct-type and indirect-type of flat-panel detector

    International Nuclear Information System (INIS)

    Matsumoto, Masao; Suekane, Koji; Ichimaru, Yasunobu; Ogata, Yuji; Inamura, Kiyonari; Kanai, Kouzou; Kanamori, Hitoshi

    2002-01-01

    A Flat-Panel Detector (FPD) has many advantages such as eliminating cassette handling and being able to display a preview image immediately in addition to the digital image processing and the networking. Thus, the FPD has ability to innovate the radiology department. We measured and evaluated the digital and over-all imaging properties (characteristic curves, modulation Transfer Functions, Wiener spectra and Noise Equivalent Quanta (NEQ) for the direct-type and indirect-type of FPD. The pre-sampling and overall NEQ of the indirect-type of FPD were better than the NEQ of the direct-type of FPD at lower spatial frequencies, but were worse at higher spatial frequencies. The FPD can take image data at real-time and be easy to digitalize. From these results, Screen/Film system and Computed Radiography system will be replaced by the FPD system, together with diffusion of CAD, cone beam Computed Tomography (CT) system and open-type Magnetic Resonance Imagining (MRI) system. (T. Tanaka)

  7. Allpix$^{2}$: A Modular Simulation Framework for Silicon Detectors

    CERN Document Server

    Spannagel, Simon; Hynds, Daniel; Alipour Tehrani, Niloufar; Benoit, Mathieu; Dannheim, Dominik; Gauvin, Neal; Nurnberg, Andreas Matthias; Schutze, Paul Jean; Vicente Barreto Pinto, Mateus

    2018-01-01

    Allpix$^{2}$ is a generic, open-source software framework for the simulation of silicon pixel detectors. Its goal is to ease the implementation of detailed simulations for both single detectors and more complex setups such as beam telescopes from incident radiation to the digitised detector response. Predefined detector types can be automatically constructed from simple model files describing the detector parameters. The simulation chain is arranged with the help of intuitive configuration files and an extensible system of modules, which implement separate simulation steps such as realistic charge carrier deposition with the Geant4 toolkit or propagation of charge carriers in silicon using a drift-diffusion model. Detailed electric field maps imported from TCAD simulations can be used to precisely model the drift behaviour of charge carriers within the silicon, bringing a new level of realism to Monte Carlo based simulations of particle detectors. This paper provides an overview of the framework and a select...

  8. Response and Uniformity Studies of Directly Coupled Tiles

    International Nuclear Information System (INIS)

    Zutshi, Vishnu

    2010-01-01

    A finely-segmented scintillator-based calorimeter which capitalizes on the marriage of proven detection techniques with novel solid-state photo-detector devices such as Multi-pixel Photon Counters (MPPCs) is an interesting calorimetric system from the point of view of future detector design. A calorimeter system consisting of millions of channels will require a high degree of integration. The first steps towards this integration have already been facilitated by the small size and magnetic field immunity of the MPPCs. The photo-conversion occurs right at the tile, thus obviating the need for routing of long clear fibers. Similar considerations apply to the presence of wave-length shifting (WLS) fibers inside the tiles which couple it to the photo-detectors. Significant simplification in construction and assembly ensue if the MPPCs can be coupled directly to the scintillator tiles. Equally importantly, the total absence of fibers would offer greater flexibility in the choice of the transverse segmentation while enhancing the electro-mechanical integrability of the design. The NIU high-energy physics group has been studying the fiberless or direct-coupling option for some time now. Encouraging results on response and response uniformity have been obtained using radioactive sources. This MOU seeks to set up a framework to extend these tests using beams at the MTBF. The results will be relevant to high granularity scintillator/crystal electromagnetic and hadronic calorimetry. The tests involve a set of small directly-coupled tile counters fabricated at NIU which will be placed in the beam to study their response and response uniformity as a function of the incident position of the particles passing through them.

  9. Response and Uniformity Studies of Directly Coupled Tiles

    Energy Technology Data Exchange (ETDEWEB)

    Zutshi, Vishnu

    2010-04-02

    A finely-segmented scintillator-based calorimeter which capitalizes on the marriage of proven detection techniques with novel solid-state photo-detector devices such as Multi-pixel Photon Counters (MPPCs) is an interesting calorimetric system from the point of view of future detector design. A calorimeter system consisting of millions of channels will require a high degree of integration. The first steps towards this integration have already been facilitated by the small size and magnetic field immunity of the MPPCs. The photo-conversion occurs right at the tile, thus obviating the need for routing of long clear fibers. Similar considerations apply to the presence of wave-length shifting (WLS) fibers inside the tiles which couple it to the photo-detectors. Significant simplification in construction and assembly ensue if the MPPCs can be coupled directly to the scintillator tiles. Equally importantly, the total absence of fibers would offer greater flexibility in the choice of the transverse segmentation while enhancing the electro-mechanical integrability of the design. The NIU high-energy physics group has been studying the fiberless or direct-coupling option for some time now. Encouraging results on response and response uniformity have been obtained using radioactive sources. This MOU seeks to set up a framework to extend these tests using beams at the MTBF. The results will be relevant to high granularity scintillator/crystal electromagnetic and hadronic calorimetry. The tests involve a set of small directly-coupled tile counters fabricated at NIU which will be placed in the beam to study their response and response uniformity as a function of the incident position of the particles passing through them.

  10. Performance of silicon drift detectors in a magnetic field

    International Nuclear Information System (INIS)

    Castoldi, A.; Gatti, E.; Manzari, V.; Rehak, P.

    1997-01-01

    A study of the properties of silicon drift detectors in a magnetic field was carried out. A silicon drift detector with 41 anodes, providing unambiguous x and y position information, was used for measurements. Studies were done in three principal orientations of the detector relative to the direction of the magnetic field. The magnetic field was varied between 0 and 0.7 T and the drift field between 300 and 600 V/cm. Basic agreement with the theory of electron transport in semiconductors in a magnetic field was found. The transport properties of electrons in a magnetic field can be described by a mobility matrix. The components of the matrix depend on the electron mobility, Hall mobility and on the vector of the magnetic field. The precision of measurement was better than 0.2% for most of the parameters. For the electric field of a silicon drift detector, there is a first-order effect of the magnetic field only in one out of three principal directions. In this direction, the plane of the detector is perpendicular to the magnetic field and electrons drift at an angle α relative to the direction of the drift field. In two other principal directions, which are more important for tracking of the particles with drift detectors, there are no first-order magnetic effects. (orig.)

  11. Energy resolution of the CdTe-XPAD detector:calibration and potential for Laue diffractionmeasurements on protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Medjoubi K.; Idir M.; Thompson, A.; Berar, J-F.; Clemens, J-C.; Delpierre, P.; Da Silva, P.; Dinkespiler, B.; Itie, J-P.; Legrand, P.; Menneglier, C.; Mercere, P.; Picca, F.; Samama J-P.

    2012-02-02

    The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL. The X-ray energy spectra of diffracted spots were deduced from the indexed Laue patterns collected with an imaging-plate detector and then measured with both the XPAD3S-CdTe and the XPAD3S-Si, a silicon photon-counting pixel array detector. The predicted and measured energy of selected diffraction spots are in good agreement, demonstrating the reliability of the calibration method. These results open up the way to direct unit-cell parameter determination and the measurement of high-quality Laue data even at low resolution. Based on the success of these measurements, potential applications in X-ray diffraction opened up by this type of technology are discussed.

  12. Photodiodes utilization as ionizing radiation detectors

    International Nuclear Information System (INIS)

    Khoury, H.J.; Melo, F.A. de

    1987-01-01

    The response of photodiodes to α and γ radiation is studied, using for α spectrometry measures and for γ radiation dosimetry. Therefore, the response of BPY-12 photodiodes as α particle detector is first studied. The results show that the response is linear with the energy of incidence radiation, one resolution 25Kev for energy of 5,4 MeV from 241 Am. For dosimetric measures, the response of SHF-206 photodiodes, when exposed at γ radiation is studied, and the results show taht the response of this detector is linear with the dose ratio, proving its practicability in γ radiation dosimetry. (C.G.C.) [pt

  13. A computational procedure to define the incidence angle on airfoils rotating around an axis orthogonal to flow direction

    International Nuclear Information System (INIS)

    Bianchini, Alessandro; Balduzzi, Francesco; Ferrara, Giovanni; Ferrari, Lorenzo

    2016-01-01

    Highlights: • New method to calculate the incidence angle from a computed CFD flow field. • Applicable to each airfoil rotating around an axis orthogonal to flow direction. • Composed by four, easily automatable steps explained in details. • Robustness of the model assessed on two Darrieus turbine study cases. - Abstract: Numerical simulations provided in the last few years a significant contribution for a better understanding of many phenomena connected to the flow past rotating blades. In case of airfoils rotating around an axis orthogonal to flow direction, one of the most critical issues is represented by the definition of the incidence angle on the airfoil from the computed flow field. Incidence indeed changes continuously as a function of the azimuthal position of the blade and a distribution of peripheral speed is experienced along the airfoil’s thickness due to radius variation. The possibility of reducing the flow to lumped parameters (relative speed modulus and direction), however, would be of capital relevance to transpose accurate CFD numerical results into effective inputs to low-order models that are often exploited for preliminary design analyses. If several techniques are available for this scope in the case of blades rotating around an axis parallel to flow direction (e.g., horizontal-axis wind turbines), the definition of a robust procedure in case the revolution axis is orthogonal to the flow is still missing. In the study, a novel technique has been developed using data from Darrieus-like rotating airfoils. The method makes use of the virtual camber theory to define a virtual airfoil whose pressure coefficient distributions in straight flow are used to match those of the real airfoil in curved flow. Even if developed originally for vertical-axis wind turbines, the method is of general validity and is thought to represent in the near future a valuable tool for researchers to get a new insight on many complex phenomena connected to flow

  14. Time dispersion in large plastic scintillation neutron detectors

    International Nuclear Information System (INIS)

    De, A.; Dasgupta, S.S.; Sen, D.

    1993-01-01

    Time dispersion (TD) has been computed for large neutron detectors using plastic scintillators. It has been shown that TD seen by the PM tube does not necessarily increase with incident neutron energy, a result not fully in agreement with the usual finding

  15. Sources, instrumentation and detectors for protein crystallography

    CERN Document Server

    Nave, C

    2001-01-01

    Some of the requirements for protein crystallography experiments on a synchrotron are described. Although data from different types of crystal are often collected without changing the X-ray beam properties, there are benefits if the incident beam is matched to a particular crystal and its diffraction pattern. These benefits are described with some examples. Radiation damage and other effects impose limits on the dose and dose rate on a protein crystal if the maximum amount of data is to be obtained. These limitations have possible consequences for the X-ray source required. Presently available commercial detector systems provide excellent data for protein crystallography but do not quite reach the specifications of the 'ideal' detector. In order to collect the most accurate data (e.g. for very weak anomalous scattering applications) detectors that produce near photon counting statistics over a wide dynamic range are required. It is possible that developments in 'pixel' detectors will allow these demanding exp...

  16. Modeling indirect detectors for performance optimization of a digital mammographic detector for dual energy applications

    International Nuclear Information System (INIS)

    Martini, N; Koukou, V; Sotiropoulou, P; Nikiforidis, G; Kalyvas, N; Michail, C; Valais, I; Kandarakis, I; Fountos, G; Bakas, A

    2015-01-01

    Dual Energy imaging is a promising method for visualizing masses and microcalcifications in digital mammography. The advent of two X-ray energies (low and high) requires a suitable detector. The scope of this work is to determine optimum detector parameters for dual energy applications. The detector was modeled through the linear cascaded (LCS) theory. It was assumed that a phosphor material was coupled to a CMOS photodetector (indirect detection). The pixel size was 22.5 μm. The phosphor thickness was allowed to vary between 20mg/cm 2 and 160mg/cm 2 The phosphor materials examined where Gd 2 O 2 S:Tb and Gd 2 O 2 S:Eu. Two Tungsten (W) anode X-ray spectra at 35 kV (filtered with 100 μm Palladium (Pd)) and 70 kV (filtered with 800 pm Ytterbium (Yb)), corresponding to low and high energy respectively, were considered to be incident on the detector. For each combination the contrast- to-noise ratio (CNR) and the detector optical gain (DOG), showing the sensitivity of the detector, were calculated. The 40 mg/cm 2 and 70 mg/cm 2 Gd 2 O 2 S:Tb exhibited the higher DOG values for the low and high energy correspondingly. Higher CNR between microcalcification and mammary gland exhibited the 70mg/cm 2 and the 100mg/cm 2 Gd 2 O 2 S:Tb for the low and the high energy correspondingly

  17. The Cosmic Ray Tracking (CRT) detector system

    International Nuclear Information System (INIS)

    Bernloehr, K.; Gamp, S.; Hermann, G.; Hofmann, W.; Kihm, T.; Knoeppler, J.; Leffers, G.; Matheis, V.; Panter, M.; Trunk, U.; Ulrich, M.; Wolf, T.; Zink, R.; Heintze, J.

    1996-01-01

    The Cosmic Ray Tracking (CRT) project represents a study on the use of tracking detectors of the time projection chamber type to detect secondary cosmic ray particles in extensive air showers. In reconstructing the arrival direction of the primary cosmic ray particles, the CRT detectors take advantage of the angular correlation of secondary particles with the cosmic rays leading to these air showers. In this paper, the detector hardware including the custom-designed electronics system is described in detail. A CRT detector module provides an active area of 2.5 m 2 and allows to measure track directions with a precision of 0.4 circle . It consists of two circular drift chambers of 1.8 m diameter with six sense wires each, and a 10 cm thick iron plate between the two chambers. Each detector has a local electronics box with a readout, trigger, and monitoring system. The detectors can distinguish penetrating muons from other types of charged secondaries. A large detector array could be used to search for γ-ray point sources at energies above several TeV and for studies of the cosmic-ray composition. Ten detectors are in operation at the site of the HEGRA air shower array. (orig.)

  18. Systematic study of Si-based GeSn photodiodes with 2.6 µm detector cutoff for short-wave infrared detection.

    Science.gov (United States)

    Pham, Thach; Du, Wei; Tran, Huong; Margetis, Joe; Tolle, John; Sun, Greg; Soref, Richard A; Naseem, Hameed A; Li, Baohua; Yu, Shui-Qing

    2016-03-07

    Normal-incidence Ge 1-x Sn x photodiode detectors with Sn compositions of 7 and 10% have been demonstrated. Such detectors were based on Ge/Ge 1-x Sn x /Ge double heterostructures grown directly on a Si substrate via a chemical vapor deposition system. A temperature-dependence study of these detectors was conducted using both electrical and optical characterizations from 300 to 77 K. Spectral response up to 2.6 µm was achieved for a 10% Sn device at room temperature. The peak responsivity and specific detectivity (D*) were measured to be 0.3 A/W and 4 × 10 9 cmHz 1/2 W -1 at 1.55 µm, respectively. The spectral D* of a 7% Sn device at 77 K was only one order-of-magnitude lower than that of an extended-InGaAs photodiode operating in the same wavelength range, indicating the promising future of GeSn-based photodetectors.

  19. An ionization-chamber type of focal-plane detector for heavy ions

    International Nuclear Information System (INIS)

    Erskine, J.R.; Braid, T.H.; Stolfzfus, J.C.

    1976-01-01

    A focal-plane detector for heavy ions is described in which energy loss and total energy are measured with a gridded ionization chamber, and position along the focal plane and angle of incidence are measured with two resistive-wire proportional counters. The clean geometry of the detector makes it especially attractive for use with heavy ions of high specific ionization. Typical position resolutions of 1.0-1.5mm (fwhm) were observed over a 50 cm length of the detector in the focal plane of a split-pole magnetic spectrograph. Special tests were made which suggest that the limiting position resolution is 0.76 mm or better. The resolution of the energy-loss signal was typically 4.5% (fwhm). The resolution of the total energy signal was 1.0-1.5% (fwhm) for small entrance apertures of the spectrograph, although 0.7% resolution was observed under special circumstances. The angle of incidence was measured with an uncertainty of about 1.2% (fwhm). The availability of the many parameters needed for particle identification makes this detector especially useful for the study of weak reaction channels in heavy-ion-induced reactions. (Auth.)

  20. Long-distance transmission of light in a scintillator-based radiation detector

    Science.gov (United States)

    Dowell, Jonathan L.; Talbott, Dale V.; Hehlen, Markus P.

    2017-07-11

    Scintillator-based radiation detectors capable of transmitting light indicating the presence of radiation for long distances are disclosed herein. A radiation detector can include a scintillator layer and a light-guide layer. The scintillator layer is configured to produce light upon receiving incident radiation. The light-guide layer is configured to receive light produced by the scintillator layer and either propagate the received light through the radiation detector or absorb the received light and emit light, through fluorescence, that is propagated through the radiation detector. A radiation detector can also include an outer layer partially surrounding the scintillator layer and light-guide layer. The index of refraction of the light-guide layer can be greater than the index of refraction of adjacent layers.

  1. Automatic luminous reflections detector using global threshold with increased luminosity contrast in images

    Science.gov (United States)

    Silva, Ricardo Petri; Naozuka, Gustavo Taiji; Mastelini, Saulo Martiello; Felinto, Alan Salvany

    2018-01-01

    The incidence of luminous reflections (LR) in captured images can interfere with the color of the affected regions. These regions tend to oversaturate, becoming whitish and, consequently, losing the original color information of the scene. Decision processes that employ images acquired from digital cameras can be impaired by the LR incidence. Such applications include real-time video surgeries, facial, and ocular recognition. This work proposes an algorithm called contrast enhancement of potential LR regions, which is a preprocessing to increase the contrast of potential LR regions, in order to improve the performance of automatic LR detectors. In addition, three automatic detectors were compared with and without the employment of our preprocessing method. The first one is a technique already consolidated in the literature called the Chang-Tseng threshold. We propose two automatic detectors called adapted histogram peak and global threshold. We employed four performance metrics to evaluate the detectors, namely, accuracy, precision, exactitude, and root mean square error. The exactitude metric is developed by this work. Thus, a manually defined reference model was created. The global threshold detector combined with our preprocessing method presented the best results, with an average exactitude rate of 82.47%.

  2. A successful experimental observation of double-photon Compton scattering of γ rays using a single γ detector

    International Nuclear Information System (INIS)

    Saddi, M.B.; Sandhu, B.S.; Singh, B.

    2006-01-01

    The phenomenon of double-photon Compton scattering has been successfully observed using a single γ detector, a technique avoiding the use of the complicated slow-fast coincidence set-up used till now for observing this higher-order process. Here doubly differential collision cross-sections integrated over the directions of one of the two final photons, the direction of other one being kept fixed, are measured experimentally for 0.662 MeV incident γ photons. The energy spectra of the detected photons are observed as a long tail to the single-photon Compton line on the lower side of the full energy peak in the recorded scattered energy spectrum. The present results are in agreement with theory of this process

  3. Response of CR-39 based personnel neutron dosemeter in terms of directional dose equivalent, in free air and on phantom

    International Nuclear Information System (INIS)

    Pal, Rupali R.; Sathian, Deepa; Jayalakshmi, V.; Chougaonkar, M.P.

    2011-01-01

    CR-39 is the most sensitive of nuclear track detectors for protons and is recommended as an effective neutron dosimeter because of it's low threshold energy of 100 keV neutrons. The fraction of protons that gives detectable tracks in CR-39 depends on the energy of the proton angle of incidence and etching conditions. As a consequence the registration efficiency of neutrons in the CR-39 plastics used for neutron personnel monitoring is strongly influenced by the direction of radiation incidence. This paper presents the relative response of CR-39 at varying neutron incident angles, for 241 Am-Be neutron source spectra in free air and on ISO phantom, in terms of operational quantities. It is observed that the angular dependence of CR-39 for irradiations in air and on phantom is essentially the same indicating that the phantom does not affect the directional response of CR-39. (author)

  4. Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for TolTEC and Beyond

    Science.gov (United States)

    Austermann, J. E.; Beall, J. A.; Bryan, S. A.; Dober, B.; Gao, J.; Hilton, G.; Hubmayr, J.; Mauskopf, P.; McKenney, C. M.; Simon, S. M.; Ullom, J. N.; Vissers, M. R.; Wilson, G. W.

    2018-05-01

    Microwave kinetic inductance detectors (MKIDs) provide a compelling path forward to the large-format polarimeter, imaging, and spectrometer arrays needed for next-generation experiments in millimeter-wave cosmology and astronomy. We describe the development of feedhorn-coupled MKID detectors for the TolTEC millimeter-wave imaging polarimeter being constructed for the 50-m Large Millimeter Telescope (LMT). Observations with TolTEC are planned to begin in early 2019. TolTEC will comprise ˜ 7000 polarization-sensitive MKIDs and will represent the first MKID arrays fabricated and deployed on monolithic 150 mm diameter silicon wafers—a critical step toward future large-scale experiments with over 10^5 detectors. TolTEC will operate in observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to define a physically independent focal plane for each passband, thus allowing the polarimeters to use simple, direct-absorption inductive structures that are impedance matched to incident radiation. This work is part of a larger program at NIST-Boulder to develop MKID-based detector technologies for use over a wide range of photon energies spanning millimeter-waves to X-rays. We present the detailed pixel layout and describe the methods, tools, and flexible design parameters that allow this solution to be optimized for use anywhere in the millimeter and sub-millimeter bands. We also present measurements of prototype devices operating in the 1.1 mm band and compare the observed optical performance to that predicted from models and simulations.

  5. Detector materials: germanium and silicon

    International Nuclear Information System (INIS)

    Haller, E.E.

    1981-11-01

    This article is a summary of a short course lecture given in conjunction with the 1981 Nuclear Science Symposium. The basic physical properties of elemental semiconductors are reviewed. The interaction of energetic radiation with matter is discussed in order to develop a feeling for the appropriate semiconductor detector dimensions. The extremely low net dopant concentrations which are required are derived directly from the detector dimensions. A survey of the more recent techniques which have been developed for the analysis of detector grade semiconductor single crystals is presented

  6. Charge correlation measurements of double-sided direct-coupled silicon mirostrip detectors

    International Nuclear Information System (INIS)

    Wood, M.L.; Kuehler, J.F.; Kalbfleisch, G.R.; Kaplan, D.H.; Skubic, P.; Lucas, A.D.; Wilburn, C.D.

    1991-01-01

    Charge correlation measurements of several Micron 38 mm by 58 mm by 300 micron thick double-sided DC-coupled microstripe detectors have been made. They have been bench tested with a Sr-90 source, with the detectors operated at -22C. The correlation of the charges collected from both the diode ('holes') and the ohmic ('electrons') stripes are equal within a signal to noise resolution of 20:1 (i.e., 1,200 electrons noise) using common-mode subtracted double-correlated sampling with the Berkeley SVXD readout chip

  7. Diamond detector time resolution for large angle tracks

    Energy Technology Data Exchange (ETDEWEB)

    Chiodini, G., E-mail: chiodini@le.infn.it [INFN - Sezione di Lecce (Italy); Fiore, G.; Perrino, R. [INFN - Sezione di Lecce (Italy); Pinto, C.; Spagnolo, S. [INFN - Sezione di Lecce (Italy); Dip. di Matematica e Fisica “Ennio De Giorgi”, Uni. del Salento (Italy)

    2015-10-01

    The applications which have stimulated greater interest in diamond sensors are related to detectors close to particle beams, therefore in an environment with high radiation level (beam monitor, luminosity measurement, detection of primary and secondary-interaction vertices). Our aims is to extend the studies performed so far by developing the technical advances needed to prove the competitiveness of this technology in terms of time resolution, with respect to more usual ones, which does not guarantee the required tolerance to a high level of radiation doses. In virtue of these goals, measurements of diamond detector time resolution with tracks incident at different angles are discussed. In particular, preliminary testbeam results obtained with 5 GeV electrons and polycrystalline diamond strip detectors are shown.

  8. Silicon drift detectors coupled to CsI(Tl) scintillators for spaceborne gamma-ray detectors

    International Nuclear Information System (INIS)

    Marisaldi, M.; Fiorini, C.; Labanti, C.; Longoni, A.; Perotti, F.; Rossi, E.; Soltau, H.

    2006-01-01

    Silicon Drift Detectors (SDDs), thanks to their peculiar low noise characteristics, have proven to be excellent photodetectors for CsI(Tl) scintillation light detection. Two basic detector configurations have been developed: either a single SDD or a monolithic array of SDDs coupled to a single CsI(Tl) crystal. A 16 independent detectors prototype is under construction, designed to work in conjunction with the MEGA Compton telescope prototype under development at MPE, Garching, Germany. A single SDD coupled to a CsI(Tl) crystal has also been tested as a monolithic detector with an extended energy range between 1.5 keV and 1 MeV. The SDD is used as a direct X-ray detector for low energy photons interacting in silicon and as a scintillation light photodetector for photons interacting in the crystal. The type of interaction is identified by means of pulse shape discrimination technique. Detectors based on an array of SDDs coupled to a single CsI(Tl) crystal have also been built. The readout of these detectors is based on the Anger camera technique, and submillimeter spatial resolution can be achieved. The two detectors' approaches and their applications will be described

  9. Submicron position-sensitive detector

    Energy Technology Data Exchange (ETDEWEB)

    Pugatch, V M; Rosenfeld, A B; Litovchenko, P G; Barabash, L I; Nemets, O F; Pavlenko, Yu N; Vasiliev, Yu O [Ukrainian Academy of Sciences, Kiev (Ukraine). Inst. for Nuclear Research

    1992-08-01

    A method has been developed to measure precisely the coordinates of charged particles incident between adjacent strips of a strip detector. The position sensitivity of an inter-strip gap has been studied by means of a pulsed laser beam and irradiation by [alpha]-particles of a [sup 226]Ra-source. The capacitive division of charge generated by the incident particle depends on the position of its track. Its coordinates were determined by two-dimensional amplitude analysis of the charges collected by neighbouring strips. This method of coordinate determination applied to studies of spatial and energy distributions of electromagnetic as well as charged particle beams (including radioactive ion beams) of low intensity could provide the highest level of the precision limited by the track dimensions of charged particles, i.e. percents of a micrometer. (orig.).

  10. Microelectronics used for Semiconductor Imaging Detectors

    CERN Document Server

    Heijne, Erik H M

    2010-01-01

    Semiconductor crystal technology, microelectronics developments and nuclear particle detection have been in a relation of symbiosis, all the way from the beginning. The increase of complexity in electronics chips can now be applied to obtain much more information on the incident nuclear radiation. Some basic technologies are described, in order to acquire insight in possibilities and limitations for the most recent detectors.

  11. Dosimetric measurements of an 192Ir HDR source with a diamond detector

    International Nuclear Information System (INIS)

    Rustgi, Surendra N.

    1996-01-01

    for the dosimetry of brachytherapy sources. It has the advantage of being water equivalent and its radiation sensitivity is independent of the photon energy and is isotropic with incident radiation direction. Due to its small sensitive volume, it exhibits excellent spatial resolution. The diamond detector also allows for real time measurements in a water phantom

  12. Cherenkov Detector for Beam Quality Measurement

    CERN Document Server

    AUTHOR|(CDS)2078842

    2016-01-01

    A new detector to measure the machine induced background at larger radiihas been developed and installed in the CMS experiment at LHC. Itconsists of 40 modules, each comprising a quartz bar read out by aphotomultiplier. Since Cerenkov radiation is emitted in a forward conearound the charged particle trajectory, these detectors can distinguishthe directions of the machine induced background.The back-end consists of a microTCA readout with excellent time resolution.The performance of the detector modules measured in several test-beamcampaigns will be reported. The installation in CMS will be described, andfirst results about operating the detector during data taking will begiven.

  13. WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

    International Nuclear Information System (INIS)

    Russ, M; Nagesh, S Setlur; Ionita, C; Bednarek, D; Rudin, S; Scott, C; Karim, K

    2015-01-01

    Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an

  14. WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Nagesh, S Setlur; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States); Scott, C; Karim, K [University of Waterloo, Waterloo, ON (Canada)

    2015-06-15

    Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an

  15. Small Angle X-Ray Scattering Detector

    Energy Technology Data Exchange (ETDEWEB)

    Hessler, Jan P.

    2004-06-15

    A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., qmax/qmin approx=lO0.

  16. The HERMES recoil detector

    International Nuclear Information System (INIS)

    Airapetian, A.; Belostotski, S.

    2013-02-01

    For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1Tm. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.

  17. The HERMES recoil detector

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Laboratory of Physics; Aschenauer, E.C. [DESY, Zeuthen (Germany); Belostotski, S. [B.P. Konstantinov Petersburg Nuclear Physics Insitute, Gatchina (Russian Federation)] [and others; Collaboration: HERMES Recoil Detector Group

    2013-02-15

    For the final running period of HERA, a recoil detector was installed at the HERMES experiment to improve measurements of hard exclusive processes in charged-lepton nucleon scattering. Here, deeply virtual Compton scattering is of particular interest as this process provides constraints on generalised parton distributions that give access to the total angular momenta of quarks within the nucleon. The HERMES recoil detector was designed to improve the selection of exclusive events by a direct measurement of the four-momentum of the recoiling particle. It consisted of three components: two layers of double-sided silicon strip sensors inside the HERA beam vacuum, a two-barrel scintillating fibre tracker, and a photon detector. All sub-detectors were located inside a solenoidal magnetic field with an integrated field strength of 1Tm. The recoil detector was installed in late 2005. After the commissioning of all components was finished in September 2006, it operated stably until the end of data taking at HERA end of June 2007. The present paper gives a brief overview of the physics processes of interest and the general detector design. The recoil detector components, their calibration, the momentum reconstruction of charged particles, and the event selection are described in detail. The paper closes with a summary of the performance of the detection system.

  18. Detectors for Tomorrow's Instruments

    Science.gov (United States)

    Moseley, Harvey

    2009-01-01

    Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

  19. Development of a High Dynamic Range Pixel Array Detector for Synchrotrons and XFELs

    Science.gov (United States)

    Weiss, Joel Todd

    Advances in synchrotron radiation light source technology have opened new lines of inquiry in material science, biology, and everything in between. However, x-ray detector capabilities must advance in concert with light source technology to fully realize experimental possibilities. X-ray free electron lasers (XFELs) place particularly large demands on the capabilities of detectors, and developments towards diffraction-limited storage ring sources also necessitate detectors capable of measuring very high flux [1-3]. The detector described herein builds on the Mixed Mode Pixel Array Detector (MM-PAD) framework, developed previously by our group to perform high dynamic range imaging, and the Adaptive Gain Integrating Pixel Detector (AGIPD) developed for the European XFEL by a collaboration between Deustsches Elektronen-Synchrotron (DESY), the Paul-Scherrer-Institute (PSI), the University of Hamburg, and the University of Bonn, led by Heinz Graafsma [4, 5]. The feasibility of combining adaptive gain with charge removal techniques to increase dynamic range in XFEL experiments is assessed by simulating XFEL scatter with a pulsed infrared laser. The strategy is incorporated into pixel prototypes which are evaluated with direct current injection to simulate very high incident x-ray flux. A fully functional 16x16 pixel hybrid integrating x-ray detector featuring several different pixel architectures based on the prototypes was developed. This dissertation describes its operation and characterization. To extend dynamic range, charge is removed from the integration node of the front-end amplifier without interrupting integration. The number of times this process occurs is recorded by a digital counter in the pixel. The parameter limiting full well is thereby shifted from the size of an integration capacitor to the depth of a digital counter. The result is similar to that achieved by counting pixel array detectors, but the integrators presented here are designed to tolerate a

  20. Reconstruction of source location in a network of gravitational wave interferometric detectors

    International Nuclear Information System (INIS)

    Cavalier, Fabien; Barsuglia, Matteo; Bizouard, Marie-Anne; Brisson, Violette; Clapson, Andre-Claude; Davier, Michel; Hello, Patrice; Kreckelbergh, Stephane; Leroy, Nicolas; Varvella, Monica

    2006-01-01

    This paper deals with the reconstruction of the direction of a gravitational wave source using the detection made by a network of interferometric detectors, mainly the LIGO and Virgo detectors. We suppose that an event has been seen in coincidence using a filter applied on the three detector data streams. Using the arrival time (and its associated error) of the gravitational signal in each detector, the direction of the source in the sky is computed using a χ 2 minimization technique. For reasonably large signals (SNR>4.5 in all detectors), the mean angular error between the real location and the reconstructed one is about 1 deg. . We also investigate the effect of the network geometry assuming the same angular response for all interferometric detectors. It appears that the reconstruction quality is not uniform over the sky and is degraded when the source approaches the plane defined by the three detectors. Adding at least one other detector to the LIGO-Virgo network reduces the blind regions and in the case of 6 detectors, a precision less than 1 deg. on the source direction can be reached for 99% of the sky

  1. Gamma ray energy loss spectra simulation in NaI detectors with the Monte Carlo method

    International Nuclear Information System (INIS)

    Vieira, W.J.

    1982-01-01

    With the aim of studying and applying the Monte Carlo method, a computer code was developed to calculate the pulse height spectra and detector efficiencies for gamma rays incident on NaI (Tl) crystals. The basic detector processes in NaI (Tl) detectors are given together with an outline of Monte Carlo methods and a general review of relevant published works. A detailed description of the application of Monte Carlo methods to ν-ray detection in NaI (Tl) detectors is given. Comparisons are made with published, calculated and experimental, data. (Author) [pt

  2. Benchmarking the Geant4 full system simulation of an associated alpha-particle detector for use in a D-T neutron generator.

    Science.gov (United States)

    Zhang, Xiaodong; Hayward, Jason P; Cates, Joshua W; Hausladen, Paul A; Laubach, Mitchell A; Sparger, Johnathan E; Donnald, Samuel B

    2012-08-01

    The position-sensitive alpha-particle detector used to provide the starting time and initial direction of D-T neutrons in a fast-neutron imaging system was simulated with a Geant4-based Monte Carlo program. The whole detector system, which consists of a YAP:Ce scintillator, a fiber-optic faceplate, a light guide, and a position-sensitive photo-multiplier tube (PSPMT), was modeled, starting with incident D-T alphas. The scintillation photons, whose starting time follows the distribution of a scintillation decay curve, were produced and emitted uniformly into a solid angle of 4π along the track segments of the alpha and its secondaries. Through tracking all photons and taking into account the quantum efficiency of the photocathode, the number of photoelectrons and their time and position distributions were obtained. Using a four-corner data reconstruction formula, the flood images of the alpha detector with and without optical grease between the YAP scintillator and the fiber-optic faceplate were obtained, which show agreement with the experimental results. The reconstructed position uncertainties of incident alpha particles for both cases are 1.198 mm and 0.998 mm respectively across the sensitive area of the detector. Simulation results also show that comparing with other faceplates composed of 500 μm, 300 μm, and 100 μm fibers, the 10-μm-fiber faceplate is the best choice to build the detector for better position performance. In addition, the study of the background originating inside the D-T generator suggests that for 500-μm-thick YAP:Ce coated with 1-μm-thick aluminum, and very good signal-to-noise ratio can be expected through application of a simple threshold. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Energy loss and online directional track visualization of fast electrons with the pixel detector Timepix

    Czech Academy of Sciences Publication Activity Database

    Granja, C.; Krist, Pavel; Chvátil, David; Šolc, J.; Pospíšil, S.; Jakubek, J.; Opalka, L.

    2013-01-01

    Roč. 59, DEC (2013), s. 245-261 ISSN 1350-4487 Institutional support: RVO:61389005 Keywords : interaction of radiation with matter * dE/dx detectors * particle tracking detectors * hybrid pixel detectors * active nuclear emulsion * energy loss Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.140, year: 2013

  4. A zonal wavefront sensor with multiple detector planes

    Science.gov (United States)

    Pathak, Biswajit; Boruah, Bosanta R.

    2018-03-01

    A conventional zonal wavefront sensor estimates the wavefront from the data captured in a single detector plane using a single camera. In this paper, we introduce a zonal wavefront sensor which comprises multiple detector planes instead of a single detector plane. The proposed sensor is based on an array of custom designed plane diffraction gratings followed by a single focusing lens. The laser beam whose wavefront is to be estimated is incident on the grating array and one of the diffracted orders from each grating is focused on the detector plane. The setup, by employing a beam splitter arrangement, facilitates focusing of the diffracted beams on multiple detector planes where multiple cameras can be placed. The use of multiple cameras in the sensor can offer several advantages in the wavefront estimation. For instance, the proposed sensor can provide superior inherent centroid detection accuracy that can not be achieved by the conventional system. It can also provide enhanced dynamic range and reduced crosstalk performance. We present here the results from a proof of principle experimental arrangement that demonstrate the advantages of the proposed wavefront sensing scheme.

  5. Evaluation of XRI-UNO CdTe detector for nuclear medical imaging

    International Nuclear Information System (INIS)

    Jambi, L.K.; Lees, J.E.; Bugby, S.L.; Alqahtani, M.S.; Tipper, S.; Perkins, A.C.

    2015-01-01

    Over the last two decades advances in semiconductor detector technology have reached the point where they are sufficiently sensitive to become an alternative to scintillators for high energy gamma ray detection for application in fields such as medical imaging. This paper assessed the Cadmium-Telluride (CdTe) XRI-UNO semiconductor detector produced by X-RAY Imatek for photon energies of interest in nuclear imaging. The XRI-UNO detector was found to have an intrinsic spatial resolution of <0.5mm and a high incident count rate capability up to at least 1680cps. The system spatial resolution, uniformity and sensitivity characteristics are also reported

  6. Dark matter spin determination with directional direct detection experiments

    Science.gov (United States)

    Catena, Riccardo; Conrad, Jan; Döring, Christian; Ferella, Alfredo Davide; Krauss, Martin B.

    2018-01-01

    If dark matter has spin 0, only two WIMP-nucleon interaction operators can arise as leading operators from the nonrelativistic reduction of renormalizable single-mediator models for dark matter-quark interactions. Based on this crucial observation, we show that about 100 signal events at next generation directional detection experiments can be enough to enable a 2 σ rejection of the spin 0 dark matter hypothesis in favor of alternative hypotheses where the dark matter particle has spin 1 /2 or 1. In this context, directional sensitivity is crucial since anisotropy patterns in the sphere of nuclear recoil directions depend on the spin of the dark matter particle. For comparison, about 100 signal events are expected in a CF4 detector operating at a pressure of 30 torr with an exposure of approximately 26,000 cubic-meter-detector days for WIMPs of 100 GeV mass and a WIMP-fluorine scattering cross section of 0.25 pb. Comparable exposures require an array of cubic meter time projection chamber detectors.

  7. The darkside multiton detector for the direct dark matter search

    International Nuclear Information System (INIS)

    Aalseth, C. E.; Agnes, P.; Alton, A.; Arisaka, K.; Asner, D. M.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Brigatti, A.; Brodsky, J.; Budano, F.; Cadonati, L.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Cavalcante, P.; Chepurnov, A.; Cocco, A. G.; Condon, C.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Deo, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Foxe, M.; Franco, D.; Gabriele, F.; Galbiati, C.; Goretti, A.; Grandi, L.; Gromov, M.; Guan, M. Y.; Guardincerri, Y.; Hackett, B.; Herner, K.; Hime, A.; Humble, P.; Hungerford, E.; Ianni, Al.; Ianni, An.; Jaffe, D. E.; Jollet, C.; Keeter, K.; Kendziora, C.; Kidner, S.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kurlej, A.; Li, P. X.; Lissia, M.; Lombardi, P.; Ludhova, L.; Luitz, S.; Lukyachenko, G.; Ma, Y. Q.; Machulin, I.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Markov, D.; Martoff, J.; Meregaglia, A.; Meroni, E.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B.; Muratova, V.; Musico, P.; Montanari, D.; Nelson, A.; Odrowski, S.; Odrzywolek, A.; Orrell, J. L.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Parsells, B.; Pelczar, K.; Pelliccia, N.; Perasso, S.; Perasso, L.; Pocar, A.; Pordes, S.; Pugachev, D.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Recine, K.; Reinhold, B.; Renshaw, A.; Romani, A.; Rossi, N.; Rossi, B.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Segreto, E.; Semenov, D.; Shields, E.; Skorokhvatov, M.; Smallcomb, M.; Smirnov, O.; Sotnikov, A.; Suvurov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Unzhakov, E.; Vogelaar, R. B.; Wada, M.; Walker, S. E.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Williams, R.; Wojcik, M.; Xu, J.; Yang, C. G.; Yoo, J.; Yu, B.; Zavatarelli, S.; Zhong, W. L.; Zuzel, G.

    2015-01-01

    Although the existence of dark matter is supported by many evidences, based on astrophysical measurements, its nature is still completely unknown. One major candidate is represented by weakly interacting massive particles (WIMPs), which could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The DarkSide program aims at the WIPMs detection using a liquid argon time projection chamber (LAr-TPC). In this paper we quickly review the DarkSide program focusing in particular on the next generation experiment DarkSide-G2, a 3.6-ton LAr-TPC. The different detector components are described as well as the improvements needed to scale the detector from DarkSide-50 (50 kg LAr-TPC) up to DarkSide-G2. Finally, the preliminary results on background suppression and expected sensitivity are presented

  8. SVX/silicon detector studies

    International Nuclear Information System (INIS)

    Bagby, L.; Johnson, M.; Lipton, R.; Gu, W.

    1995-11-01

    AC coupled silicon detectors, being used for the DO upgrade, may have substantial voltage across the coupling capacitor. Failed capacitors can present ∼50 V to the input of the SVX, Silicon Vertex, device. We measured the effects that failed detector coupling capacitors have on the SVXD (rad soft 3μm), SVXH (rad hard 1.2μm), and SVXIIb (rad soft 1.2μm) amplifier / readout devices. The test results show that neighboring channels saturate when an excessive voltage is applied directly to a SVX channel. We believe that the effects are due to current diffusion within the SVX substrate rather than surface currents on the detectors. This paper discusses the magnitude of the saturation and a possible solution to the problem

  9. Automated and angular time-synchronized directional gamma-ray scintillation sensor

    International Nuclear Information System (INIS)

    Kronenberg, S.; Brucker, G.J.

    1998-01-01

    The authors' previous research resulted in directional sensors for gamma rays and X rays that have a 4π solid angle of acceptance and, at the same time, a high angular resolution that is limited only by their ability to measure small angles. Angular resolution of ∼1 s of arc was achieved. These sensors are capable of operating and accurately detecting high and very low intensity radiation patterns. Such a system can also be used to image broad area sources and their scattering patterns. The principle of operation and design of directional sensors used in this study was described elsewhere; however, for convenience, a part of that text is repeated here. It was shown analytically that the angular distribution of radiation incident on the sensor is proportional to the first derivative of the scan data, that is, of the events' count rate versus orientation of the detector. The previously published results were obtained with a annual operating system. The detector assembly was set at a specific angle, and a pulse rate count was made. This was repeated at numerous other angles of orientation, a time-consuming and labor-intensive process. Recently, the authors automated this system, which is based on the detection of scintillations. The detector, which consists of a stack of plates of Lucite, plastic scintillator, and lead foils, rotates by means of a motor in front of a stationary photomultiplier tube (PMT). One revolution per second was chosen for the motor. At time zero, a trigger indicates that a revolution has started. The angle of orientation of the detector in the laboratory system is proportional to the time during one revolution. The process repeats itself a desired number of times. The trigger signal initiates a scan of a multichannel scalar (MCS). The detector assembly is allowed to rotate in the radiation field, and the MCS scans are repeated in an accumulated mode of operation until enough events are collected for the location of the radiation source to be

  10. Monitoring of absolute mirror alignment at COMPASS RICH-1 detector

    NARCIS (Netherlands)

    Alexeev, M.; Birsa, R.; Bradamante, F.; Bressan, A.; Chiosso, M.; Ciliberti, P.; Dalla Torre, S.; Denisov, O.; Duic, V.; Ferrero, A.; Finger, M.; Finger, M.; Gayde, J. Ch; Giorgi, M.; Gobbo, B.; Levorato, S.; Maggiora, A.; Martin, A.; Menon, G.; Panzieri, D.; Pesaro, G.; Polak, J.; Rocco, E.; Sbrizzai, G.; Schiavon, P.; Slunecka, M.; Sozzi, F.; Steiger, L.; Sulc, M.; Takekawa, S.; Tessarotto, F.

    2014-01-01

    The gaseous COMPASS RICH-1 detector uses two spherical mirror surfaces, segmented into 116 individual mirrors, to focus the Cherenkov photons onto the detector plane. Any mirror misalignment directly affects the detector resolution. The on-line Continuous Line Alignment and Monitoring (CLAM)

  11. A large-area scintillation detector with matrix readout for experiments at COSY

    International Nuclear Information System (INIS)

    Wolke, M.

    1993-12-01

    For the requirement of a time-of-flight measurement in the framework of the experiment E5 at the proton synchrotron COSY Juelich by means of a Monte-Carlo simulation the geometrical parameters of a large-area scintillator plane with matrix-arrangement of the read-out photomultipliers could be optimized. A system for the monitoring of the tube amplifications, basing on short light pulses emitted by luminescence diodes, was modificatedly transeferred to this application and successfully tested. For the time resolution of the detector values could be determined, which lie in the mean by about 30 % above the theoretical expectations. For minimally ionizing particles an accuracy of the time-of-flight information from the combination of start and stop scintillator of the experiment E5 in a range σ tof ∼240-260 ps dependent on the incident position of the particle to be analyzed, was measured. On the base of this measurement for protons of a momentum of 1 GeV/c at application of the detector in its second construction stage an upper limit of the time-of-flight resolution of correspondingly σ tof ∼195-220 ps is to be expected. From this a crude upper estimation of the momentum resolution of σ p /p∼1.0-1.2 % results. A position reconstruction by means of the c. m. method showed qualitatively an expected behaviour of the systematic deviations between reconstructed and real incidence positions. Quantitativeley a mean fluctuation of the reconstructed positions of 1.3 respectively 0.8 cm for the horizontal respectively vertical direction is reached

  12. Determination of nuclear tracks parameters on sequentially etched PADC detectors

    Science.gov (United States)

    Horwacik, Tomasz; Bilski, Pawel; Koerner, Christine; Facius, Rainer; Berger, Thomas; Nowak, Tomasz; Reitz, Guenther; Olko, Pawel

    Polyallyl Diglycol Carbonate (PADC) detectors find many applications in radiation protection. One of them is the cosmic radiation dosimetry, where PADC detectors measure the linear energy transfer (LET) spectra of charged particles (from protons to heavy ions), supplementing TLD detectors in the role of passive dosemeter. Calibration exposures to ions of known LET are required to establish a relation between parameters of track observed on the detector and LET of particle creating this track. PADC TASTRAK nuclear track detectors were exposed to 12 C and 56 Fe ions of LET in H2 O between 10 and 544 keV/µm. The exposures took place at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan in the frame of the HIMAC research project "Space Radiation Dosimetry-Ground Based Verification of the MATROSHKA Facility" (20P-240). Detectors were etched in water solution of NaOH with three different temperatures and for various etching times to observe the appearance of etched tracks, the evolution of their parameters and the stability of the etching process. The applied etching times (and the solution's concentrations and temperatures) were: 48, 72, 96, 120 hours (6.25 N NaOH, 50 O C), 20, 40, 60, 80 hours (6.25 N NaOH, 60 O C) and 8, 12, 16, 20 hours (7N NaOH, 70 O C). The analysis of the detectors involved planimetric (2D) measurements of tracks' entrance ellipses and mechanical measurements of bulk layer thickness. Further track parameters, like angle of incidence, track length and etch rate ratio were then calculated. For certain tracks, results of planimetric measurements and calculations were also compared with results of optical track profile (3D) measurements, where not only the track's entrance ellipse but also the location of the track's tip could be directly measured. All these measurements have been performed with the 2D/3D measurement system at DLR. The collected data allow to create sets of V(LET in H2 O) calibration curves suitable for short, intermediate and

  13. High performance visual display for HENP detectors

    CERN Document Server

    McGuigan, M; Spiletic, J; Fine, V; Nevski, P

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactiv...

  14. A self-powered thin-film radiation detector using intrinsic high-energy current

    Energy Technology Data Exchange (ETDEWEB)

    Zygmanski, Piotr, E-mail: pzygmanski@LROC.HARVARD.EDU, E-mail: Erno-Sajo@uml.edu [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Sajo, Erno, E-mail: pzygmanski@LROC.HARVARD.EDU, E-mail: Erno-Sajo@uml.edu [Department of Physics and Applied Physics, Medical Physics Program, University of Massachusetts Lowell, Lowell, Massachusetts 01854 (United States)

    2016-01-15

    Purpose: The authors introduce a radiation detection method that relies on high-energy current (HEC) formed by secondary charged particles in the detector material, which induces conduction current in an external readout circuit. Direct energy conversion of the incident radiation powers the signal formation without the need for external bias voltage or amplification. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. The optimal design of HEC detectors consists of microscopic or nanoscopic structures. Methods: Theoretical and computational developments are presented to illustrate the salient properties of the HEC detector and to demonstrate its feasibility. In this work, the authors examine single-sandwiched and periodic layers of Cu and Al, and Au and Al, ranging in thickness from 100 nm to 300 μm and separated by similarly sized dielectric gaps, exposed to 120 kVp x-ray beam (half-value thickness of 4.1 mm of Al). The energy deposition characteristics and the high-energy current were determined using radiation transport computations. Results: The authors found that in a dual-layer configuration, the signal is in the measurable range. For a defined total detector thickness in a multilayer structure, the signal sharply increases with decreasing thickness of the high-Z conductive layers. This paper focuses on the computational results while a companion paper reports the experimental findings. Conclusions: Significant advantages of the device are that it does not require external power supply and amplification to create a measurable signal; it can be made in any size and geometry, including very thin (sub-millimeter to submicron) flexible curvilinear forms, and it is inexpensive. Potential applications include medical dosimetry (both in vivo and external), radiation protection, and other settings where one or more of the above qualities are desired.

  15. Technology of fabrication of silicon-lithium detector with superficial junction

    International Nuclear Information System (INIS)

    Cabal Rodriguez, A.E.; Diaz Garcia, A.; Noriega Scull, C.

    1997-01-01

    The Silicon nuclear radiation detectors transform the charge produced within the semiconductor crystal, product of the impinges of particles and X rays, in pulses of voltage at the output of the preamplifier. The planar Silicon-Lithium (Si(Li)) detector with superficial junction is basically a Pin structure diode. By mean of the diffusion and drift of Lithium in the Silicon a compensated or depletion region was created. There the incident radiation interacts with the Silicon, producing an electric signal proportional to the detector's energy deposited in the semiconductor. The technological process of fabrication this kind of detectors comprises several stages, some of them complex and of long duration. They also demand a systematic control. The technological process of Si(Li) detector's fabrication was carried out. The detector's fabrication electric characteristics were measured in some steps. An obtained device was mounted in the holder within a cryostat, in order to work to temperature of the liquid nitrogen. The energy resolution of the detector was measured and the value was 180 eV for the line of 5.9 KeV of an Fe-55 source. This value has allowed to work with the detector in energy disperse X-rays fluorescence. (author) [es

  16. TORCH—a Cherenkov based time-of-flight detector

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, M.W.U. van, E-mail: m.vandijk@bristol.ac.uk [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Brook, N.H. [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Castillo García, L. [European Organisation for Nuclear Research (CERN), CH-1211 Geneva 23 (Switzerland); Laboratory for High Energy Physics, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Cowie, E.N.; Cussans, D. [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); D' Ambrosio, C. [European Organisation for Nuclear Research (CERN), CH-1211 Geneva 23 (Switzerland); Fopma, J. [Denys Wilkinson Laboratory, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Forty, R.; Frei, C. [European Organisation for Nuclear Research (CERN), CH-1211 Geneva 23 (Switzerland); Gao, R. [Denys Wilkinson Laboratory, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Gys, T. [European Organisation for Nuclear Research (CERN), CH-1211 Geneva 23 (Switzerland); Harnew, N.; Keri, T. [Denys Wilkinson Laboratory, University of Oxford, Keble Road, Oxford OX1 3RH (United Kingdom); Piedigrossi, D. [European Organisation for Nuclear Research (CERN), CH-1211 Geneva 23 (Switzerland)

    2014-12-01

    TORCH is an innovative high-precision time-of-flight system to provide particle identification in the difficult intermediate momentum region up to 10 GeV/c. It is also suitable for large-area applications. The detector provides a time-of-flight measurement from the imaging of Cherenkov photons emitted in a 1 cm thick quartz radiator. The photons propagate by total internal reflection to the edge of the quartz plate and are then focused onto an array of photon detectors at the periphery. A time-of-flight resolution of about 10–15 ps per incident charged particle needs to be achieved to allow a three sigma kaon-pion separation up to 10 GeV/c momentum for the TORCH located 9.5 m from the interaction point. Given ∼30 detected photons per incident charged particle, this requires measuring the time-of-arrival of individual photons to about 70 ps. This paper will describe the design of a TORCH prototype involving a number of ground-breaking and challenging techniques.

  17. A proposal for both plasma ion- and electron-temperature diagnostics under simultaneous incidence of particles and x-rays into a semiconductor on the basis of a proposed model for a semiconductor detector response

    International Nuclear Information System (INIS)

    Numakura, T; Cho, T; Kohagura, J; Hirata, M; Minami, R; Yoshida, M; Nakashima, Y; Tamano, T; Yatsu, K; Miyoshi, S

    2003-01-01

    A method is proposed for obtaining radial profiles of plasma temperatures of both plasma ion (T i ) and electron (T e ) simultaneously by the use of a semiconductor detector array. The method is based on our developed particle-response model for a semiconductor detector; in particular, the response theory is constructed for giving the applicability in particle energies ranging down to a kiloelectronvolt. Calculated results from our model are in fairly good agreement with experimental data on the detector response of incident particle beams with energies in the range 100 eV to a few kiloelectronvolts. On the basis of the verification of the proposed model, an idea of the use of a developed semiconductor detector array covered with 'reliably unbreakable' ultrathin SiO 2 'dead-layer filters' having various nanometre-order thicknesses is applied for simultaneous T i and T e analyses by using charge-exchange neutral particles and x-rays from plasmas. Radial profiles of T i and T e are obtained in a single plasma discharge alone, and the data reliability is independently cross-checked by a radial scan of a conventional charge-exchange neutral-particle analyser system as well as a 50-channel microchannel plate x-ray diagnostics system in the GAMMA 10 tandem mirror

  18. Beam test of CSES silicon strip detector module

    Science.gov (United States)

    Zhang, Da-Li; Lu, Hong; Wang, Huan-Yu; Li, Xin-Qiao; Xu, Yan-Bing; An, Zheng-Hua; Yu, Xiao-xia; Wang, Hui; Shi, Feng; Wang, Ping; Zhao, Xiao-Yun

    2017-05-01

    The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. A low-noise analog ASIC VA140 was used in this study for DSSD signal readout. A beam test on the DSSD module was performed at the Beijing Test Beam Facility of the Beijing Electron Positron Collider (BEPC) using a 400-800 MeV/c proton beam. The pedestal analysis results, RMSE noise, gain correction, and intensity distribution of incident particles of the DSSD module are presented. Supported by the XXX Civil Space Programme

  19. An annular ionization detector for quasi-elastic and transfer reaction studies

    CERN Document Server

    Dinesh, B V; Nayak, B K; Biswas, D C; Saxena, A; Pant, L M; Sahu, P K; Choudhury, R K

    2000-01-01

    An annular ionization chamber detector has been developed to study quasi-elastic and transfer reactions in heavy-ion collisions at near-barrier and sub-barrier energies. The important feature of the detector is that it has a near 2 pi coverage in the azimuthal angle phi for the particles entering in the detector at a given theta direction. This feature makes the detector very useful for measurement of the differential cross-sections at backward angles with respect to the beam direction, involving low cross-section reaction channels. The split anode configuration of the detector makes it capable of both particle identification and energy measurement for heavy ions and fission fragments. The detector has been tested using heavy-ion beams from the 14 MV-pelletron accelerator at Mumbai. Results on quasi-elastic excitation function measurements and barrier distribution studies in many heavy-ion reactions using this detector setup are discussed.

  20. Flat-response x-ray-diode-detector development

    International Nuclear Information System (INIS)

    Tirsell, G.

    1982-10-01

    In this report we discuss the design of an improved sub-nanosecond flat response x-ray diode detector needed for ICF diagnostics. This device consists of a high Z cathode and a complex filter tailored to flatten the response so that the total x-ray energy below 1.5 keV can be measured using a single detector. Three major problems have become evident as a result of our work with the original LLNL design including deviation from flatness due to a peak in the response below 200 eV, saturation at relatively low x-ray fluences, and long term gold cathode instability. We are investigating grazing incidence reflection to reduce the response below 200 eV, new high Z cathode materials for long term stability, and a new complex filter for improved flatness. Better saturation performance will require a modified XRD detector under development with reduced anode to cathode spacing and increased anode bias voltage

  1. Controlling optical properties of periodic gold nanoparticle arrays by changing the substrate, topologic shapes of nanoparticles, and polarization direction of incident light

    International Nuclear Information System (INIS)

    Ting, Li; Li, Yu; Zhi-Xin, Lu; Gang, Song; Kai, Zhang

    2011-01-01

    The effects of various parameters including thickness and dielectric constants of substrates, shapes of nanoparticles, and polarization direction of incident light, on the extinction spectra of periodic gold nanoparticle arrays are investigated by the full-vectorial three-dimensional (3D) finite difference time domain (FDTD) method. The calculated results show that the substrate affects the extinction spectra by coupling the fields co-excited by the substrate and gold nanoparticles. Extinction spectra are influenced by the shapes of the nanoparticles, but there are no obvious changes in extinction spectra for similar shapes. The polarization direction of incident light has a great influence on the extinction spectra. The implications of these results are discussed. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  2. The GLAST Large Area Telescope Detector Performance Monitoring

    International Nuclear Information System (INIS)

    Borgland, A.W.; Charles, E.; SLAC

    2007-01-01

    The Large Area Telescope (LAT) is one of two instruments on board the Gamma-ray Large Area Telescope (GLAST), the next generation high energy gamma-ray space telescope. The LAT contains sixteen identical towers in a four-by-four grid. Each tower contains a silicon-strip tracker and a CsI calorimeter that together will give the incident direction and energy of the pair-converting photon in the energy range 20 MeV - 300 GeV. In addition, the instrument is covered by a finely segmented Anti-Coincidence Detector (ACD) to reject charged particle background. Altogether, the LAT contains more than 864k channels in the trackers, 1536 CsI crystals and 97 ACD plastic scintillator tiles and ribbons. Here we detail some of the strategies and methods for how we are planning to monitor the instrument performance on orbit. It builds on the extensive experience gained from Integration and Test and Commissioning of the instrument on ground

  3. Measurement of depth-dose distributions by means of the LiF-fluoroplastic thermoluminescent detectors

    International Nuclear Information System (INIS)

    Shaks, A.I.; Uryaev, I.A.; Trifonov, V.A.; Reshetnikova, L.V.

    1977-01-01

    Depth-dose distributions have been studied by means of thin-layer thermoluminescent detectors LiF-fluoroplast (8 mg/cm 2 ). Dosimetric characteristics of the detectors are described. They are: tissue-equivalence, dependence of sensitivity on the dose, dose rate and angle of incidence of radiation, and time-dependent storage, of the total light absorbed. Comparison of the results obtained with the measurements taken with an extrapolation chamber has demonstrated the possibility of measuring the depth-dose distributions by means of LiF-fluoroplast detectors

  4. MARTA: A high-energy cosmic-ray detector concept with high-accuracy muon measurement

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, P.; et al.

    2017-12-20

    A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. The combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.

  5. Moving Forward - Progress on Forward Detectors

    CERN Multimedia

    Grafstrom, P.

    2006-01-01

    You might have been sitting in some meeting hearing about the ATLAS forward detectors. Coming back to your office wanting to learn more you look in the ATLAS TDR’s and disappointingly you find nothing about forward detectors. The explanation is of course that the forward detectors are newcomers in the ATLAS detector arsenal. ATLAS is designed to measure high Pt particles with pseudo rapidities up to 5 which in terms of angles means angles bigger than one degree (0.8 degree to be more accurate). Particles produced with smaller angles close to the beam escape detection. The hole in the forward direction will now partly be filled. Several new detectors have recently been proposed. These detectors are designed for various luminosity measurements but they also have a physics potential in themselves. Closest to the IP there is LUCID (LUminosity measurement using Cerenkov Integrating Detector). LUCID comprises some 170 Cerenkov tubes sitting around the beam pipe at about 17 m away from the IP. The tubes are 1.5 ...

  6. Detection of secondary electrons with pixelated hybrid semiconductor detectors

    International Nuclear Information System (INIS)

    Gebert, Ulrike Sonja

    2011-01-01

    Within the scope of this thesis, secondary electrons were detected with a pixelated semiconductor detector named Timepix. The Timepix detector consists of electronics and a sensor made from a semiconductor material. The connection of sensor and electronics is done for each pixel individually using bump bonds. Electrons with energies above 3 keV can be detected with the sensor. One electron produces a certain amount of electron-hole pairs according to its energy. The charge then drifts along an electric field to the pixel electronics, where it induces an electric signal. Even without a sensor it is possible to detect an electric signal from approximately 1000 electrons directly in the pixel electronics. Two different detector systems to detect secondary electrons using the Timepix detector were investigated during this thesis. First of all, a hybrid photon detector (HPD) was used to detect single photoelectrons. The HPD consists of a vacuum vessel with an entrance window and a cesium iodine photocathode at the inner surface of the window. Photoelectrons are released from the photocathode by incident light and are accelerated in an electric field towards the Timepix detector, where the point of interaction and the arrival time of the electron is determined. With a proximity focusing setup, a time resolution of 12 ns (with an acceleration voltage of 20 kV between photocathode and Timepix detector) was obtained. The HPD examined in this thesis showed a strong dependence of the dark rate form the acceleration voltage and the pressure in the vacuum vessel. At a pressure of few 10 -5 mbar and an acceleration voltage of 20 kV, the dark rate was about 800 Hz per mm 2 area of the read out photocathode. One possibility to reduce the dark rate is to identify ion feedback events. With a slightly modified setup it was possible to reduce the dark rate to 0.5 Hz/mm 2 . To achieve this, a new photocathode was mounted in a shorter distance to the detector. The measurements where

  7. Simulating Makrofol as a detector for neutron-induced recoils

    International Nuclear Information System (INIS)

    Zhang, G.; Becker, F.; Urban, M.; Xuan, Y.

    2011-01-01

    The response of solid-state nuclear track detector is extremely dependent on incident angles of neutrons, which determine the angular distribution of secondary particles. In this paper, the authors present a method to investigate the angular response of Makrofol detectors. Using the C++-based Monte-Carlo tool-kit Geant4 in combination with SRIM and our MATLAB codes, we simulated the angular response of Makrofol. The simulations were based on the restricted energy loss model, and the concept of energy threshold and critical angle. Experiments were carried out with 252 Cf neutrons to verify the simulation results. (authors)

  8. A position sensitive gamma-ray detector which employs photodiode and CsI (T1) crystals

    International Nuclear Information System (INIS)

    Dean, A.J.; Graham, G.; Hopkins, C.J.; Ramsden, D.; Lei, M.

    1987-01-01

    A compact CsI(Tl)/photodiode gamma-ray detector is described which is capable of locating the point of interaction of incident gamma-ray photons in the spectral region around 1 MeV. Laboratory tests are used to quantify both the spectral and positional resolutions of the detectors. Their likely application in space gamma-ray astronomy is also discussed

  9. Diamond detector technology: status and perspectives

    CERN Document Server

    Kagan, Harris; Artuso, M; Bachmair, F; Bäni, L; Bartosik, M; Beacham, J; Beck, H P; Bellini,, V; Belyaev, V; Bentele, B; Berdermann, E; Bergonzo, P; Bes, A; Brom, J-M; Bruzzi, M; Cerv, M; Chiodini, G; Chren, D; Cindro, V; Claus, G; Collot, J; Cumalat, J; Dabrowski, A; D'Alessandro, R; De Boer, W; Dehning, B; Dorfer, C; Dunser, M; Eremin, V; Eusebi, R; Forcolin, G; Forneris, J; Frais-Kölbl, H; Gan, K K; Gastal, M; Giroletti, C; Goffe, M; Goldstein, J; Golubev, A; Gorišek, A; Grigoriev, E; Grosse-Knetter, J; Grummer, A; Gui, B; Guthoff, M; Haughton, I; Hiti, B; Hits, D; Hoeferkamp, M; Hofmann, T; Hosslet, J; Hostachy, J-Y; Hügging, F; Hutton, C; Jansen, H; Janssen, J; Kanxheri, K; Kasieczka, G; Kass, R; Kassel, F; Kis, M; Kramberger, G; Kuleshov, S; Lacoste, A; Lagomarsino, S; Lo Giudice, A; Lukosi, E; Maazouzi, C; Mandic, I; Mathieu, C; Mcfadden, N; Menichelli, M; Mikuž, M; Morozzi, A; Moss, J; Mountain, R; Murphy, S; Muškinja, M; Oh, A; Oliviero, P; Passeri, D; Pernegger, H; Perrino, R; Picollo, F; Pomorski, M; Potenza, R; Quadt, A; Re, A; Reichmann, M; Riley, G; Roe, S; Sanz, D; Scaringella, M; Schaefer, D; Schmidt, C J; Schnetzer, S; Schreiner, T; Sciortino, S; Scorzoni, A; Seidel, S; Servoli, L; Sopko, B; Sopko, V; Spagnolo, S; Spanier, S; Stenson, K; Stone, R; Sutera, C; Taylor, Aaron; Traeger, M; Tromson, D; Trischuk, W; Tuve, C; Uplegger, L; Velthuis, J; Venturi, N; Vittone, E; Wagner, Stephen; Wallny, R; Wang, J C; Weingarten, J; Weiss, C; Wengler, T; Wermes, N; Yamouni, M; Zavrtanik, M

    2017-01-01

    The status of material development of poly-crystalline chemical vapor deposition (CVD) diamond is presented. We also present beam test results on the independence of signal size on incident par-ticle rate in charged particle detectors based on un-irradiated and irradiated poly-crystalline CVD diamond over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2. The pulse height of the sensors was measured with readout electronics with a peaking time of 6 ns. In addition the first beam test results from 3D detectors made with poly-crystalline CVD diamond are presented. Finally the first analysis of LHC data from the ATLAS Diamond Beam Monitor (DBM) which is based on pixelated poly-crystalline CVD diamond sensors bump-bonded to pixel readout elec-tronics is shown.

  10. Flat-panel detectors in x-ray diagnosis

    International Nuclear Information System (INIS)

    Spahn, M.; Heer, V.; Freytag, R.

    2003-01-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography, mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method.For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications.Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography.Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods. (orig.) [de

  11. Calorimeter based detectors for high energy hadron colliders

    International Nuclear Information System (INIS)

    1993-01-01

    The work was directed in two complementary directions, the D0 experiment at Fermilab, and the GEM detector for the SSC. Efforts have been towards the data taking and analysis with the newly commissioned D0 detector at Fermilab in the bar pp Collider run that started in May 1992 and ended on June 1, 1993. We involved running and calibration of the calorimeter and tracking chambers, the second level trigger development, and various parts of the data analysis, as well as studies for the D0 upgrade planned in the second half of this decade. Another major accomplishment was the ''delivery'' of the Technical Design Report for the GEM SSC detector. Efforts to the overall detector and magnet design, design of the facilities, installation studies, muon system coordination, muon chamber design and tests, muon system simulation studies, and physics simulation studies. In this document we describe these activities separately

  12. Averaged currents induced by alpha particles in an InSb compound semiconductor detector

    International Nuclear Information System (INIS)

    Kanno, Ikuo; Hishiki, Shigeomi; Kogetsu, Yoshitaka; Nakamura, Tatsuya; Katagiri, Masaki

    2008-01-01

    Very fast pulses due to alpha particle incidence were observed by an undoped-type InSb Schottky detector. This InSb detector was operated without applying bias voltage and its depletion layer thickness was less than the range of alpha particles. The averaged current induced by alpha particles was analyzed as a function of operating temperature and was shown to be proportional to the Hall mobility of InSb. (author)

  13. Cutaneous contamination after a uranyl nitrate skin burn: incident report

    International Nuclear Information System (INIS)

    Berard, P.; Chalabreysse, J.; Quesne, B.; Auriol, B.

    1994-01-01

    The authors review the circumstances of a handburn incident by a mixture of dilute nitric acid and uranyl nitrate. The burn was localised on the thumb and three fingers of the left hand. After abundant washing, external direct measurements revealed the presence of uranium on the fingers. The injured employee was maintained under observation for ten days, and therapy was performed until all the activity disappeared. External monitoring with various detectors, and measurements of the bandages and skin showed a rapid decrease of uranium fixation. All urine was collected throughout the duration of the treatment. The study shows that all the activity was retained on the burnt skin, with very little systemic uptake. Rapid peeling eliminated the cutaneous retention. Internal and external dose assessments were calculated and the committed effective dose equivalent and the committed dose equivalent for the skin and bone surfaces were low. (author)

  14. Digital radiography with large-area flat-panel detectors

    International Nuclear Information System (INIS)

    Kotter, E.; Langer, M.

    2002-01-01

    Large-area flat-panel detectors with active readout mechanisms have been on the market for the past 2 years. This article describes different detector technologies. An important distinction is made between detectors with direct and those with indirect conversion of X-rays into electrical charges. Detectors with indirect conversion are built with unstructured or structured scintillators, the latter resulting in less lateral diffusion of emitted light. Some important qualities of flat-panel detectors are discussed. The first phantom and clinical studies published report an image quality at least comparable to that of screen-film systems and a potential for dose reduction. The available studies are summarised in this article. (orig.)

  15. The development of a gas-filled time-of-flight detector

    International Nuclear Information System (INIS)

    Guan Yongjing; He Ming; Ruan Xiangdong; Wang Huijuan; Wu Shaoyong; Dong Kejun; Lin Min; Yuan Jian; Jiang Shan

    2007-01-01

    A gas-filled time-of-flight (GF-TOF) detector system for isobaric identification has been developed at the AMS facility of the China Institute of Atomic Energy (CIAE). The newly built GF-TOF detector was tested by using a 36 Cl standard sample ( 36 Cl/Cl = 2.88 x 10 -11 ) with the 36 Cl ion energies of 64, 49 and 33 MeV. Time resolutions of 350 ps, 580 ps and 920 ps were obtained for 64, 49 and 33 MeV 36 S, respectively, without gas. 36 Cl and 36 S particles were successfully separated in the TOF spectra from the GF-TOF detector at the three different incident energies. The dependence of time resolution and separation power of GF-TOF method on the incidence energy and the residual energy is discussed. The comparison of separation power for isobars between the GF-TOF method and the ΔE-E method is described. A combination of GF-TOF method and ΔE-E method may further improve the separation power for isobars. The results show that the sensitivity for 36 Cl AMS measurements is 10 -14 at the energy of 33 MeV. Some results obtained with the GF-TOF method are given

  16. Hybrid organic/inorganic position-sensitive detectors based on PEDOT:PSS/n-Si

    Science.gov (United States)

    Javadi, Mohammad; Gholami, Mahdiyeh; Torbatiyan, Hadis; Abdi, Yaser

    2018-03-01

    Various configurations like p-n junctions, metal-semiconductor Schottky barriers, and metal-oxide-semiconductor structures have been widely used in position-sensitive detectors. In this report, we propose a PEDOT:PSS/n-Si heterojunction as a hybrid organic/inorganic configuration for position-sensitive detectors. The influence of the thickness of the PEDOT:PSS layer, the wavelength of incident light, and the intensity of illumination on the device performance are investigated. The hybrid PSD exhibits very high sensitivity (>100 mV/mm), excellent nonlinearity (0.995) with a response time of heterojunction are very promising for developing a new class of position-sensitive detectors based on the hybrid organic/inorganic junctions.

  17. Diamond detectors for high energy physics experiments

    Science.gov (United States)

    Bäni, L.; Alexopoulos, A.; Artuso, M.; Bachmair, F.; Bartosik, M.; Beacham, J.; Beck, H.; Bellini, V.; Belyaev, V.; Bentele, B.; Berdermann, E.; Bergonzo, P.; Bes, A.; Brom, J.-M.; Bruzzi, M.; Cerv, M.; Chiodini, G.; Chren, D.; Cindro, V.; Claus, G.; Collot, J.; Cumalat, J.; Dabrowski, A.; D'Alessandro, R.; Dauvergne, D.; de Boer, W.; Dorfer, C.; Dünser, M.; Eremin, V.; Eusebi, R.; Forcolin, G.; Forneris, J.; Frais-Kölbl, H.; Gallin-Martel, L.; Gallin-Martel, M. L.; Gan, K. K.; Gastal, M.; Giroletti, C.; Goffe, M.; Goldstein, J.; Golubev, A.; Gorišek, A.; Grigoriev, E.; Grosse-Knetter, J.; Grummer, A.; Gui, B.; Guthoff, M.; Haughton, I.; Hiti, B.; Hits, D.; Hoeferkamp, M.; Hofmann, T.; Hosslet, J.; Hostachy, J.-Y.; Hügging, F.; Hutton, C.; Jansen, H.; Janssen, J.; Kagan, H.; Kanxheri, K.; Kasieczka, G.; Kass, R.; Kassel, F.; Kis, M.; Konovalov, V.; Kramberger, G.; Kuleshov, S.; Lacoste, A.; Lagomarsino, S.; Lo Giudice, A.; Lukosi, E.; Maazouzi, C.; Mandic, I.; Mathieu, C.; Menichelli, M.; Mikuž, M.; Morozzi, A.; Moss, J.; Mountain, R.; Murphy, S.; Muškinja, M.; Oh, A.; Oliviero, P.; Passeri, D.; Pernegger, H.; Perrino, R.; Picollo, F.; Pomorski, M.; Potenza, R.; Quadt, A.; Re, A.; Reichmann, M.; Riley, G.; Roe, S.; Sanz, D.; Scaringella, M.; Schaefer, D.; Schmidt, C. J.; Schnetzer, S.; Sciortino, S.; Scorzoni, A.; Seidel, S.; Servoli, L.; Smith, S.; Sopko, B.; Sopko, V.; Spagnolo, S.; Spanier, S.; Stenson, K.; Stone, R.; Sutera, C.; Tannenwald, B.; Taylor, A.; Traeger, M.; Tromson, D.; Trischuk, W.; Tuve, C.; Uplegger, L.; Velthuis, J.; Venturi, N.; Vittone, E.; Wagner, S.; Wallny, R.; Wang, J. C.; Weingarten, J.; Weiss, C.; Wengler, T.; Wermes, N.; Yamouni, M.; Zavrtanik, M.

    2018-01-01

    Beam test results of the radiation tolerance study of chemical vapour deposition (CVD) diamond against different particle species and energies is presented. We also present beam test results on the independence of signal size on incident particle rate in charged particle detectors based on un-irradiated and irradiated poly-crystalline CVD diamond over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2. The pulse height of the sensors was measured with readout electronics with a peaking time of 6 ns. In addition functionality of poly-crystalline CVD diamond 3D devices was demonstrated in beam tests and 3D diamond detectors are shown to be a promising technology for applications in future high luminosity experiments.

  18. Silicon lithium detector for x ray fluorescence

    International Nuclear Information System (INIS)

    Rodriguez Cabal, A. E.; Diaz Garcia, A.; Noriega Scull, C.; Martinez Munoz, O.; Diaz Cepeda, R.

    1997-01-01

    The Silicon Lithium detector is the system for the detection of nuclear radiation. It transforms the charge that was produced inside of Silicon material as a result of the incidence of particles and X rays, in voltage pulses at the output of the preamplifier. In this work was made the adjustment of the technological process of manufacture of the detector. Also was made the design and construction of the cryostat and preamplifier and then the validation of the system in a Cuban Dewar. The system, which was made for the first time in our country, has an energy resolution of 185 eV for the Fe-55 source (E=5.9 KeV), which has permitted its implementation in energy dispersive X ray fluorescence. (author) [es

  19. Gas chromatography: mass selective detector

    International Nuclear Information System (INIS)

    Lapinskas, R.

    1988-01-01

    The mechanism of mass spectrometry technique directed for detecting molecular structures is described, with some considerations about its operational features. This mass spectrometer is used as a gas chromatography detector. (author)

  20. Gamma ray polarimetry using a position sensitive germanium detector

    CERN Document Server

    Kroeger, R A; Kurfess, J D; Phlips, B F

    1999-01-01

    Imaging gamma-ray detectors make sensitive polarimeters in the Compton energy regime by measuring the scatter direction of gamma rays. The principle is to capitalize on the angular dependence of the Compton scattering cross section to polarized gamma rays and measure the distribution of scatter directions within the detector. This technique is effective in a double-sided germanium detector between roughly 50 keV and 1 MeV. This paper reviews device characteristics important to the optimization of a Compton polarimeter, and summarizes measurements we have made using a device with a 5x5 cm active area, 1 cm thickness, and strip-electrodes on a 2 mm pitch.

  1. The CRESST-III detector module

    Energy Technology Data Exchange (ETDEWEB)

    Wuestrich, Marc [Max-Planck-Institut f. Physik (Werner-Heisenberg-Institut) (Germany); Collaboration: CRESST-Collaboration

    2016-07-01

    The direct dark matter experiment CRESST uses scintillating calorimeters to detected WIMP induced nuclear scattering in CaWO{sub 4} single crystals. Equipped with transition edge sensors (TESs), these detectors can achieve detection thresholds well below 1 keV. The last physics run of CRESST-II proved the high potential of the experiment especially for small WIMP masses and triggered the development of a new detector module using much smaller CaWO{sub 4} main absorbers. The upcoming CRESST-III run will mainly be equipped with these newly developed modules, which combine a fully scintillating detector housing with an improved detection threshold (<100 keV). While many features of the new module were adapted from previous module designs in an improved way, also new features are implemented like instrumented sticks (iSticks) holding the crystals and optimized TES structures for phonon and light detectors. First tests above ground validated the improved performance of these detector modules and promise to explore new regions in the WIMP parameter space in the next CRESST-III run.

  2. Adaptive Multiuser Detectors for DS-CDMA Systems

    Directory of Open Access Journals (Sweden)

    Paul Jean Etienne Jeszensky

    2006-02-01

    Full Text Available This work makes a review of the main Adaptives Multi-user Detectors (MuD-Adpt for Direct Sequence - Code Division Multiple Access (DS-CDMA systems. The MuD-Adpt based on Minimum Mean Square Error (MMSE and Decorrelator (MuD-Dec are focused. Multi-user detectors show great resistance to the near-far effect and combat effectively the Multiple Access Interference (MAI. Comparative numeric results characterize the substantial performance improvement of those detectors in relation to the matched filter conventional receiver (Conv.

  3. Cryogenic gamma detectors enable direct detection of 236U and minor actinides for non-destructive assay

    International Nuclear Information System (INIS)

    Miguel Velazquez; Jonathan Dreyer; Drury, O.B.; Friedrich, Stephan; Saleem Salaymeh

    2016-01-01

    We demonstrate the utility of a superconducting transition edge sensor (TES) γ-ray detector with high energy resolution and low Compton background for nondestructive assay (NDA) of a uranium sample from reprocessed nuclear fuel. We show that TES γ-detectors can separate low-energy actinide γ-emissions from the background and nearby lines, even from minor isotopes whose signals are often obscured in NDA with conventional Ge detectors. Superconducting γ-detectors may therefore bridge the gap between high-accuracy destructive assay (DA) and easier-to-use NDA. (author)

  4. A directional gamma-ray detector based on scintillator plates

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, D., E-mail: hanna@physics.mcgill.ca; Sagnières, L.; Boyle, P.J.; MacLeod, A.M.L.

    2015-10-11

    A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising a plate of CsI(Tl) scintillator coupled to a photomultiplier tube, can locate a point source of gamma rays with degree-scale precision by comparing the count rates in the different modules. Sensitivity to uniform environmental background is minimal.

  5. Characterizing Subpixel Spatial Resolution of a Hybrid CMOS Detector

    Science.gov (United States)

    Bray, Evan; Burrows, Dave; Chattopadhyay, Tanmoy; Falcone, Abraham; Hull, Samuel; Kern, Matthew; McQuaide, Maria; Wages, Mitchell

    2018-01-01

    The detection of X-rays is a unique process relative to other wavelengths, and allows for some novel features that increase the scientific yield of a single observation. Unlike lower photon energies, X-rays liberate a large number of electrons from the silicon absorber array of the detector. This number is usually on the order of several hundred to a thousand for moderate-energy X-rays. These electrons tend to diffuse outward into what is referred to as the charge cloud. This cloud can then be picked up by several pixels, forming a specific pattern based on the exact incident location. By conducting the first ever “mesh experiment" on a hybrid CMOS detector (HCD), we have experimentally determined the charge cloud shape and used it to characterize responsivity of the detector with subpixel spatial resolution.

  6. Ab initio structure determination of nanocrystals of organic pharmaceutical compounds by electron diffraction at room temperature using a Timepix quantum area direct electron detector

    Energy Technology Data Exchange (ETDEWEB)

    Genderen, E. van; Clabbers, M. T. B. [Biophysical Structural Chemistry, Leiden University, Einsteinweg 55, 2333 CC Leiden (Netherlands); Center for Cellular Imaging and NanoAnalytics (C-CINA), Biozentrum, University of Basel, CH-4058 Basel (Switzerland); Das, P. P. [Nanomegas SPRL, Boulevard Edmond Machtens 79, B 1080, Brussels (Belgium); Stewart, A. [Department of Physics and Energy, Materials and Surface Science Institute (MSSI), University of Limerick, Limerick (Ireland); Nederlof, I. [Biophysical Structural Chemistry, Leiden University, Einsteinweg 55, 2333 CC Leiden (Netherlands); Amsterdam Scientific Instruments, Postbus 41882, 1009 DB Amsterdam (Netherlands); Barentsen, K. C. [Biophysical Structural Chemistry, Leiden University, Einsteinweg 55, 2333 CC Leiden (Netherlands); Portillo, Q. [Nanomegas SPRL, Boulevard Edmond Machtens 79, B 1080, Brussels (Belgium); Centres Científics i Tecnològics de la Universitat de Barcelona, University of Barcelona, Carrer de Lluís Solé i Sabaris, 1-3, Barcelona (Spain); Pannu, N. S. [Biophysical Structural Chemistry, Leiden University, Einsteinweg 55, 2333 CC Leiden (Netherlands); Nicolopoulos, S. [Nanomegas SPRL, Boulevard Edmond Machtens 79, B 1080, Brussels (Belgium); Gruene, T., E-mail: tim.gruene@psi.ch [Biology and Chemistry, Laboratory of Biomolecular Research, Paul Scherrer Institute (PSI), 5232 Villigen (Switzerland); Abrahams, J. P., E-mail: tim.gruene@psi.ch [Biophysical Structural Chemistry, Leiden University, Einsteinweg 55, 2333 CC Leiden (Netherlands); Center for Cellular Imaging and NanoAnalytics (C-CINA), Biozentrum, University of Basel, CH-4058 Basel (Switzerland); Biology and Chemistry, Laboratory of Biomolecular Research, Paul Scherrer Institute (PSI), 5232 Villigen (Switzerland)

    2016-02-05

    A specialized quantum area detector for electron diffraction studies makes it possible to solve the structure of small organic compound nanocrystals in non-cryo conditions by direct methods. Until recently, structure determination by transmission electron microscopy of beam-sensitive three-dimensional nanocrystals required electron diffraction tomography data collection at liquid-nitrogen temperature, in order to reduce radiation damage. Here it is shown that the novel Timepix detector combines a high dynamic range with a very high signal-to-noise ratio and single-electron sensitivity, enabling ab initio phasing of beam-sensitive organic compounds. Low-dose electron diffraction data (∼0.013 e{sup −} Å{sup −2} s{sup −1}) were collected at room temperature with the rotation method. It was ascertained that the data were of sufficient quality for structure solution using direct methods using software developed for X-ray crystallography (XDS, SHELX) and for electron crystallography (ADT3D/PETS, SIR2014)

  7. Neutronic analysis of the Three Mile Island Unit 2 ex-core detector response

    International Nuclear Information System (INIS)

    Malloy, D.J.; Chang, Y.I.

    1981-10-01

    A neutronic analysis has been made with respect to the ex-core neutron detector response during the TMI-2 incident. A series of transport theory calculations quantified the impact upon the detector count rate of various core and downcomer conditions. In particular, various combinations of coolant void content and spatial distributions were investigated to yield the resulting transmission of the photoneutron source to the detector. The impact of a hypothetical distributed source within the downcomer region was also examined in order to simulate the potential effect of the release of neutron producing fission products into the coolant. These results are then offered as potential explanations for the anomalous behavior of the detector during the period of approx. 20 minutes through approx. 3 hours following the reactor scram

  8. Robust MOE Detector for DS-CDMA Systems with Signature Waveform Mismatch

    Science.gov (United States)

    Lin, Tsui-Tsai

    In this letter, a decision-directed MOE detector with excellent robustness against signature waveform mismatch is proposed for DS-CDMA systems. Both the theoretic analysis and computer simulation results demonstrate that the proposed detector can provide better SINR performance than that of conventional detectors.

  9. Study of silicon microstrips detector quantum efficiency using mathematical simulation

    International Nuclear Information System (INIS)

    Leyva Pernia, Diana; Cabal Rodriguez, Ana Ester; Pinnera Hernandez, Ibrahin; Fabelo, Antonio Leyva; Abreu Alfonso, Yamiel; Cruz Inclan, Carlos M.

    2011-01-01

    The paper shows the results from the application of mathematical simulation to study the quantum efficiency of a microstrips crystalline silicon detector, intended for medical imaging and the development of other applications such as authentication and dating of cultural heritage. The effects on the quantum efficiency of some parameters of the system, such as the detector-source geometry, X rays energy and detector dead zone thickness, were evaluated. The simulation results were compared with the theoretical prediction and experimental available data, resulting in a proper correspondence. It was concluded that the use of frontal configuration for incident energies lower than 17 keV is more efficient, however the use of the edge-on configuration for applications requiring the detection of energy above this value is recommended. It was also found that the reduction of the detector dead zone led to a considerable increase in quantum efficiency for any energy value in the interval from 5 to 100 keV.(author)

  10. A custom readout electronics for the BESIII CGEM detector

    International Nuclear Information System (INIS)

    Rolo, M. Da Rocha; Alexeev, M.; Amoroso, A.; Bianchi, F.; Cossio, F.; Mori, F. De; Destefanis, M.; Ferroli, R. Baldini; Chai, J.Y.; Bertani, M.; Calcaterra, A.; Capodiferro, M.; Cerioni, S.; Bettoni, D.; Canale, N.; Carassiti, V.; Chiozzi, S.; Cibinetto, G.; Ramusino, A. Cotta; Bugalho, R.

    2017-01-01

    For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 μm while loosening the pitch strip to 650 μm, which allows to reduce the total number of channels to about 10 000. The channels are readout by 160 dedicated integrated 64-channel front-end ASICs, providing a time and charge measurement and featuring a fully-digital output. The energy measurement is extracted either from the time-over-threshold (ToT) or the 10-bit digitisation of the peak amplitude of the signal. The time of the event is generated by quad-buffered low-power TDCs, allowing for rates in excess of 60 kHz per channel. The TDCs are based on analogue interpolation techniques and produce a time stamp (or two, if working in ToT mode) of the event with a time resolution better than 50 ps. The front-end noise, based on a CSA and a two-stage complex conjugated pole shapers, dominate the channel intrinsic time jitter, which is less than 5 ns r.m.s. The time information of the hit can be used to reconstruct the track path, operating the detector as a small TPC and hence improving the position resolution when the distribution of the cloud, due to large incident angle or magnetic field, is very broad. Event data is collected by an off-detector motherboard, where each GEM-ROC readout card handles 4 ASIC carrier FEBs (512 channels). Configuration upload and data readout between the off-detector electronics and the VME-based data collector cards are managed by bi-directional fibre optical links. This paper covers the design of a custom front-end electronics for the readout of the new inner tracker of the BESIII experiment, addressing the relevant design aspects of the detector electronics and the front-end ASIC for the CGEM

  11. A custom readout electronics for the BESIII CGEM detector

    Science.gov (United States)

    Da Rocha Rolo, M.; Alexeev, M.; Amoroso, A.; Baldini Ferroli, R.; Bertani, M.; Bettoni, D.; Bianchi, F.; Bugalho, R.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Carassiti, V.; Cerioni, S.; Chai, J. Y.; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Di Francesco, A.; Dong, J.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Garzia, I.; Gatta, M.; Greco, M.; Lavezzi, L.; Leng, C. Y.; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Marciniewski, P.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Savrié, M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Varela, J.; Verma, S.; Wheadon, R.; Yan, L.

    2017-07-01

    For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM enables the use of a charge centroid algorithm to improve the spatial resolution to better than 130 μm while loosening the pitch strip to 650 μm, which allows to reduce the total number of channels to about 10 000. The channels are readout by 160 dedicated integrated 64-channel front-end ASICs, providing a time and charge measurement and featuring a fully-digital output. The energy measurement is extracted either from the time-over-threshold (ToT) or the 10-bit digitisation of the peak amplitude of the signal. The time of the event is generated by quad-buffered low-power TDCs, allowing for rates in excess of 60 kHz per channel. The TDCs are based on analogue interpolation techniques and produce a time stamp (or two, if working in ToT mode) of the event with a time resolution better than 50 ps. The front-end noise, based on a CSA and a two-stage complex conjugated pole shapers, dominate the channel intrinsic time jitter, which is less than 5 ns r.m.s. The time information of the hit can be used to reconstruct the track path, operating the detector as a small TPC and hence improving the position resolution when the distribution of the cloud, due to large incident angle or magnetic field, is very broad. Event data is collected by an off-detector motherboard, where each GEM-ROC readout card handles 4 ASIC carrier FEBs (512 channels). Configuration upload and data readout between the off-detector electronics and the VME-based data collector cards are managed by bi-directional fibre optical links. This paper covers the design of a custom front-end electronics for the readout of the new inner tracker of the BESIII experiment, addressing the relevant design aspects of the detector electronics and the front-end ASIC for the CGEM readout

  12. Improvement of Infrared Detectors for Tissue Oximetry using Black Silicon Nanostructures

    DEFF Research Database (Denmark)

    Petersen, Søren Dahl; Davidsen, Rasmus Schmidt; Alcala, Lucia R.

    2014-01-01

    We present a nanostructured surface, made of dry etched black silicon, which lowers the reflectance for light incident at all angles. This surface is fabricated on infrared detectors used for tissue oximetry, where the detection of weak diffuse light signals is important. Monte Carlo simulations...... performed on a model of a neonatal head shows that approximately 60% of the injected light will be diffuse reflected. However, the change in diffuse reflected light due to the change in cerebral oxygenation is very low and the light will be completely isotropic scattered. The reflectance of the black...... in quantum efficiency for both normal incident light and light incident at 38°....

  13. Detector line spread functions determined analytically by transport of Compton recoil electrons

    International Nuclear Information System (INIS)

    Veld, A.A. van't; Luijk, P. van; Praamstra, F.; Hulst, P.C. van der

    2001-01-01

    To achieve the maximum benefit of conformal radiation therapy it is necessary to obtain accurate knowledge of radiation beam penumbras based on high-resolution relative dosimetry of beam profiles. For this purpose there is a need to perform high-resolution dosimetry with well-established routine dosimeters, such as ionization chambers or diodes. Profiles measured with these detectors must be corrected for the dosimeter's nonideal response, caused by finite dimensions and, in the case of an ionization chamber, the alteration of electron transport and a contribution of electrons recoiled in the chamber wall and the central electrode. For this purpose the line spread function (LSF) of the detector is needed. The experimental determination of LSFs is cumbersome and restricted to the specific detector and beam energy spectrum used. Therefore, a previously reported analytical model [Med. Phys. 27, 923-934 (2000)] has been extended to determine response profiles of routine dosimeters: shielded diodes and, in particular, ionization chambers, in primary dose slit beams. The model combines Compton scattering of incident photons, the transport of recoiled electrons by Fermi-Eyges small-angle multiple scattering theory, and functions to limit electron transport. It yields the traveling direction and the energy of electrons upon incidence on the detector surface. In the case of ionization chambers, geometrical considerations are then sufficient to calculate the relative amount of ionization in chamber air, i.e., the detector response, as a function of the detector location in the slit beam. In combination with the previously reported slit beam dose profiles, the LSF can then readily be derived by reconstruction techniques. Since the spectral contributions are preserved, the LSF of a dosimeter is defined for any beam for which the effective spectrum is known. The detector response profiles calculated in this study have been verified in a telescopic slit beam geometry, and were

  14. Status of beam line detectors for the BigRIPS fragment separator at RIKEN RI Beam Factory. Issues on high rates and resolution

    International Nuclear Information System (INIS)

    Sato, Yuki; Fukuda, Naoki; Takeda, Hiroyuki

    2015-01-01

    A multiple sampling ionization chamber (MUSIC) and parallel-plate avalanche counters (PPACs) were installed within the superconducting in-flight separator, named BigRIPS, at the RIKEN Nishina Center for particle identification of RI beams. The MUSIC detector showed negligible charge collection inefficiency from recombination of electrons and ions, up to a 99-kcps incidence rate for high-energy heavy ions. For the PPAC detectors, the electrical discharge durability for incident heavy ions was improved by changing the electrode material. Finally, we designed a single crystal diamond detector, which is under development for TOF measurements of high-energy heavy ions, that has a very fast response time (pulse width <1 ns). (author)

  15. Status of Beam Line Detectors for the BigRIPS Fragment Separator at RIKEN RI Beam Factory: Issues on High Rates and Resolution

    Science.gov (United States)

    Sato, Yuki; Fukuda, Naoki; Takeda, Hiroyuki; Kameda, Daisuke; Suzuki, Hiroshi; Shimizu, Yohei; Ahn, DeukSoon; Murai, Daichi; Inabe, Naohito; Shimaoka, Takehiro; Tsubota, Masakatsu; Kaneko, Junichi H.; Chayahara, Akiyoshi; Umezawa, Hitoshi; Shikata, Shinichi; Kumagai, Hidekazu; Murakami, Hiroyuki; Sato, Hiromi; Yoshida, Koichi; Kubo, Toshiyuki

    A multiple sampling ionization chamber (MUSIC) and parallel-plate avalanche counters (PPACs) were installed within the superconducting in-flight separator, named BigRIPS, at the RIKEN Nishina Center for particle identification of RI beams. The MUSIC detector showed negligible charge collection inefficiency from recombination of electrons and ions, up to a 99-kcps incidence rate for high-energy heavy ions. For the PPAC detectors, the electrical discharge durability for incident heavy ions was improved by changing the electrode material. Finally, we designed a single crystal diamond detector, which is under development for TOF measurements of high-energy heavy ions, that has a very fast response time (pulse width <1 ns).

  16. Beam tests of ATLAS SCT silicon strip detector modules

    CERN Document Server

    Campabadal, F; Key, M; Lozano, M; Martínez, C; Pellegrini, G; Rafí, J M; Ullán, M; Johansen, L; Pommeresche, B; Stugu, B; Ciocio, A; Fadeev, V; Gilchriese, M G D; Haber, C; Siegrist, J; Spieler, H; Vu, C; Bell, P J; Charlton, D G; Dowell, John D; Gallop, B J; Homer, R J; Jovanovic, P; Mahout, G; McMahon, T J; Wilson, J A; Barr, A J; Carter, J R; Fromant, B P; Goodrick, M J; Hill, J C; Lester, C G; Palmer, M J; Parker, M A; Robinson, D; Sabetfakhri, A; Shaw, R J; Anghinolfi, F; Chesi, Enrico Guido; Chouridou, S; Fortin, R; Grosse-Knetter, J; Gruwé, M; Ferrari, P; Jarron, P; Kaplon, J; MacPherson, A; Niinikoski, T O; Pernegger, H; Roe, S; Rudge, A; Ruggiero, G; Wallny, R; Weilhammer, P; Bialas, W; Dabrowski, W; Grybos, P; Koperny, S; Blocki, J; Brückman, P; Gadomski, S; Godlewski, J; Górnicki, E; Malecki, P; Moszczynski, A; Stanecka, E; Stodulski, M; Szczygiel, R; Turala, M; Wolter, M; Ahmad, A; Benes, J; Carpentieri, C; Feld, L; Ketterer, C; Ludwig, J; Meinhardt, J; Runge, K; Mikulec, B; Mangin-Brinet, M; D'Onofrio, M; Donega, M; Moêd, S; Sfyrla, A; Ferrère, D; Clark, A G; Perrin, E; Weber, M; Bates, R L; Cheplakov, A P; Saxon, D H; O'Shea, V; Smith, K M; Iwata, Y; Ohsugi, T; Kohriki, T; Kondo, T; Terada, S; Ujiie, N; Ikegami, Y; Unno, Y; Takashima, R; Brodbeck, T; Chilingarov, A G; Hughes, G; Ratoff, P; Sloan, T; Allport, P P; Casse, G L; Greenall, A; Jackson, J N; Jones, T J; King, B T; Maxfield, S J; Smith, N A; Sutcliffe, P; Vossebeld, Joost Herman; Beck, G A; Carter, A A; Lloyd, S L; Martin, A J; Morris, J; Morin, J; Nagai, K; Pritchard, T W; Anderson, B E; Butterworth, J M; Fraser, T J; Jones, T W; Lane, J B; Postranecky, M; Warren, M R M; Cindro, V; Kramberger, G; Mandic, I; Mikuz, M; Duerdoth, I P; Freestone, J; Foster, J M; Ibbotson, M; Loebinger, F K; Pater, J; Snow, S W; Thompson, R J; Atkinson, T M; Bright, G; Kazi, S; Lindsay, S; Moorhead, G F; Taylor, G N; Bachindgagyan, G; Baranova, N; Karmanov, D; Merkine, M; Andricek, L; Bethke, Siegfried; Kudlaty, J; Lutz, Gerhard; Moser, H G; Nisius, R; Richter, R; Schieck, J; Cornelissen, T; Gorfine, G W; Hartjes, F G; Hessey, N P; de Jong, P; Muijs, A J M; Peeters, S J M; Tomeda, Y; Tanaka, R; Nakano, I; Dorholt, O; Danielsen, K M; Huse, T; Sandaker, H; Stapnes, S; Bargassa, Pedrame; Reichold, A; Huffman, T; Nickerson, R B; Weidberg, A; Doucas, G; Hawes, B; Lau, W; Howell, D; Kundu, N; Wastie, R; Böhm, J; Mikestikova, M; Stastny, J; Broklová, Z; Broz, J; Dolezal, Z; Kodys, P; Kubík, P; Reznicek, P; Vorobel, V; Wilhelm, I; Chren, D; Horazdovsky, T; Linhart, V; Pospísil, S; Sinor, M; Solar, M; Sopko, B; Stekl, I; Ardashev, E N; Golovnya, S N; Gorokhov, S A; Kholodenko, A G; Rudenko, R E; Ryadovikov, V N; Vorobev, A P; Adkin, P J; Apsimon, R J; Batchelor, L E; Bizzell, J P; Booker, P; Davis, V R; Easton, J M; Fowler, C; Gibson, M D; Haywood, S J; MacWaters, C; Matheson, J P; Matson, R M; McMahon, S J; Morris, F S; Morrissey, M; Murray, W J; Phillips, P W; Tyndel, M; Villani, E G; Dorfan, D E; Grillo, A A; Rosenbaum, F; Sadrozinski, H F W; Seiden, A; Spencer, E; Wilder, M; Booth, P; Buttar, C M; Dawson, I; Dervan, P; Grigson, C; Harper, R; Moraes, A; Peak, L S; Varvell, K E; Chu Ming Lee; Hou Li Shing; Lee Shih Chang; Teng Ping Kun; Wan Chang Chun; Hara, K; Kato, Y; Kuwano, T; Minagawa, M; Sengoku, H; Bingefors, N; Brenner, R; Ekelöf, T J C; Eklund, L; Bernabeu, J; Civera, J V; Costa, M J; Fuster, J; García, C; García, J E; González-Sevilla, S; Lacasta, C; Llosa, G; Martí i García, S; Modesto, P; Sánchez, J; Sospedra, L; Vos, M; Fasching, D; González, S; Jared, R C; Charles, E

    2005-01-01

    The design and technology of the silicon strip detector modules for the Semiconductor Tracker (SCT) of the ATLAS experiment have been finalised in the last several years. Integral to this process has been the measurement and verification of the tracking performance of the different module types in test beams at the CERN SPS and the KEK PS. Tests have been performed to explore the module performance under various operating conditions including detector bias voltage, magnetic field, incidence angle, and state of irradiation up to 3 multiplied by 1014 protons per square centimetre. A particular emphasis has been the understanding of the operational consequences of the binary readout scheme.

  17. Double Chooz Improved Multi-Detector Measurements

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero θ13 with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of θ13 followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC’s unique almost "iso-flux" site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of θ13 with respect to the world average. We will address this issue in this seminar. The combined "reactor-θ13" measurement is expected to ...

  18. A beta ray spectrometer based on a two-, or three-element silicon detector coincidence telescope

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Weizman, Y.; Hirning, C.R.

    1995-01-01

    The operation of a beta ray energy spectrometer based on a two-or three-element silicon detector telescope is described. The front detector (A) is a thin, totally depleted, silicon surface barrier detector either 40 μm, 72 μm or 98 μm thick. The back detector (C) is a Li compensated silicon detector, 5000 μm thick. An additional thin detector can be inserted between these two detectors when additional photon rejection capability is required in intense photon fields. The capability of the spectrometer to reject photons is based on the fact that incident photons will have a small probability of simultaneously losing detectable energy in two detectors and an even smaller probability of losing detectable energy in all three detectors. Electrons, however, above a low energy threshold, will always record simultaneous, events in all three detectors. The spectrometer is capable of measuring electron energies from a lower energy coincidence threshold of 70 keV with 60% efficiency increasing to 100% efficiency in the energy region between 150 keV and 2.5 MeV. (Author)

  19. Development of acoustic particle detector

    International Nuclear Information System (INIS)

    Matsuyama, Tadayoshi; Hinode, Fujio; Konno, Osamu

    1999-01-01

    To detect acoustic sign from electron, determination of acoustic radiation from high energy electron and detector were studied. When charge particles pass through medium, energy loss generates local expansion and contraction of medium and pressure compression wave. We need caustic element with 10 -5 Pa the minimum acoustic receive sensitivity and from 10 to 100 kHz frequency sensitivity characteristic. Elements were made by Low-Q materials, piezoelectric materials (PZT). Various sharp of elements were constructed and measured. 50 mm spherical element showed 38 m V/Pa, the best sensitivity. Our developed acoustic element could detect acoustic radiation generated by electron beam from accelerator. The wave sharp detected proved the same as bipolar wave, which was given theoretically. The pressure generated by beam was proportional to the energy loss E. 200 MeV electron beam existed about 95% particles on the incident axis. So that acoustic detector on the axis proved to detect sound wave generated on the beam axis. (S.Y.)

  20. The ALICE detector data link

    CERN Document Server

    Rubin, G; Csató, P; Dénes, E; Kiss, T; Meggyesi, Z; Sulyán, J; Vesztergombi, G; Eged, B; Gerencsér, I; Novák, I; Soós, C; Tarján, D; Telegdy, A; Tóth, N

    1999-01-01

    The ALICE detector data link has been designed to cover all the needs for data transfer between the detector and the data-acquisition system. It is a 1 Gbit/s, full-duplex, multi-purpose fibre optic link that can be used as a medium for the bi-directional transmission of data blocks between the front-end electronics and the data- acquisition system and also for the remote control and test of the front-end electronics, In this paper the concept, the protocol, the specific test tools, the prototypes of the detector data link and the read-out receiver card, their application in the ALICE-TPC test system and the integration with the DATE software are presented. The test results on the performance are also shown. (14 refs).

  1. Electron detector with a traVelling wave

    International Nuclear Information System (INIS)

    Goncharov, A.S.; Kazakov, V.M.; Kozlov, O.V.

    1979-01-01

    Basic principles of operation of a travelling-wave detector designed to measure the shapes of nanosecond electron pulses are discussed. Propagation of electrons through the input window into the detector results in spreading of TEM waves to both sides. The energy of the wave propagating towards resistor R is absorbed by the latter, while the wave propagating in the opposite direction hits a register. Thus good matching of all the detector elements results in the absence of reflection and standing waves which provides extremely high time resolution and minimum distortion of the electron pulse shape. The detector constitutes a piece of a cylindrical coaxial line whose impedance is equal to the impedance of a transmission line. On one side the detector is loaded onto resistor R equal to the wave resistance of the detector. On the other side the detector is loaded onto the transmission line which connects the detector with a wide-range register. The design and calculation of a detector having a time resolution of about 0.1 ns are presented. The results of testing the coaxial detector When measuring electron pulses with a duration of 60 ns and frequency of 1818 MHz have shown that the developed detector (external diameter being 63 mm, internal diameter 18 mm, length 400 mm) provides the 0.2 ns time resolution

  2. Neutron energy response measurement of scintillation detectors

    International Nuclear Information System (INIS)

    Yang Hongqiong; Peng Taiping; Yang Jianlun; Tang Zhengyuan; Yang Gaozhao; Li Linbo; Hu Mengchun; Wang Zhentong; Zhang Jianhua; Li Zhongbao; Wang Lizong

    2004-01-01

    Neutron sensitivities of detectors composed of plastic scintillator ST401, ST1422, ST1423 and phyotomultiplier tube in primary energy range of fission neutron are calibrated by direct current. The energy response curve of the detectors is obtained in this experiment. The experimental result has been compared with the theoretical calculation and they are in agreement within measuring uncertainty. (authors)

  3. Ionizing radiation detector using multimode optical fibers

    International Nuclear Information System (INIS)

    Suter, J.J.; Poret, J.C.; Rosen, M.; Rifkind, J.M.

    1993-01-01

    An optical ionizing radiation detector, based on the attenuation of 850-nm light in 50/125-μm multimode fibers, is described. The detector is especially well suited for application on spacecraft because of its small design. The detection element consists of a section of coiled fibers that has been designed to strip higher-order optical modes. Cylindrical radiation shields with atomic numbers ranging from Z = 13 (aluminum too) Z = 82 (lead) were placed around the ionizing radiation detector so that the effectiveness of the detector could be measured. By exposing the shields and the detector to 1.25-MeV cobalt 60 radiation, the mass attenuation coefficients of the shields were measured. The detector is based on the phenomenon that radiation creates optical color centers in glass fibers. Electron spin resonance spectroscopy performed on the 50/125-μm fibers showed the presence of germanium oxide and phosphorus-based color centers. The intensity of these centers is directly related to the accumulated gamma radiation

  4. Performance characteristics of CdTe drift ring detector

    Science.gov (United States)

    Alruhaili, A.; Sellin, P. J.; Lohstroh, A.; Veeramani, P.; Kazemi, S.; Veale, M. C.; Sawhney, K. J. S.; Kachkanov, V.

    2014-03-01

    CdTe and CdZnTe material is an excellent candidate for the fabrication of high energy X-ray spectroscopic detectors due to their good quantum efficiency and room temperature operation. The main material limitation is associated with the poor charge transport properties of holes. The motivation of this work is to investigate the performance characteristics of a detector fabricated with a drift ring geometry that is insensitive to the transport of holes. The performance of a prototype Ohmic CdTe drift ring detector fabricated by Acrorad with 3 drift rings is reported; measurements include room temperature current voltage characteristics (IV) and spectroscopic performance. The data shows that the energy resolution of the detector is limited by leakage current which is a combination of bulk and surface leakage currents. The energy resolution was studied as a function of incident X-ray position with an X-ray microbeam at the Diamond Light Source. Different ring biasing schemes were investigated and the results show that by increasing the lateral field (i.e. the bias gradient across the rings) the active area, evaluated by the detected count rate, increased significantly.

  5. Neutron detector

    Science.gov (United States)

    Stephan, Andrew C [Knoxville, TN; Jardret,; Vincent, D [Powell, TN

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  6. Readout technologies for directional WIMP Dark Matter detection

    International Nuclear Information System (INIS)

    Battat, J.B.R.; Irastorza, I.G.; Aleksandrov, A.; Asada, T.; Baracchini, E.; Billard, J.; Bosson, G.; Bourrion, O.; Bouvier, J.; Buonaura, A.; Burdge, K.; Cebrián, S.

    2016-01-01

    The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

  7. Characterization of HPGe detectors using Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hedman, A., E-mail: Angelica.Hedman@foi.se [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Bahar Gogani, J.; Granström, M. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Johansson, L.; Andersson, J.S. [Umeå University, Department of Radiation Sciences, Radiation Physics, SE-90187 Umeå (Sweden); Ramebäck, H. [Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-41296 Göteborg (Sweden)

    2015-06-11

    Computed Tomography (CT) high-resolution imaging have been used to investigate if there is a significant change in the crystal-to-window distance, i.e. the air gap thickness, in a small n-type detector cooled to 77 K, and in a medium sized p-type HPGe detector when cooled to 100 K. The findings were compared to detector dimension data made available by the manufacturer. The air gap thickness increased by (0.38±0.07) mm for the n-type detector and by (0.40±0.15) mm for the p-type detector when the detectors were cooled to 77 resp. 100 K compared to at room temperature. Monte Carlo calculations indicate that these differences have a significant impact on the efficiency in close geometries (<5 cm). In the energy range of 40–700 keV with a source placed directly on endcap, the change in detector efficiency with temperature is 1.9–2.9% for the n-type detector and 0.3–2.1% for the p-type detector. The measured air gap thickness when cooling the detector was 1.1 mm thicker than manufacturer data for the n-type detector and 0.2 mm thicker for the p-type detector. In the energy range of 40–700 keV and with a source on endcap, this result in a change in detector efficiency of 5.2–7.1% for the n-type detector and 0.2–1.0% for the p-type detector, i.e. the detector efficiency is overestimated using data available by the manufacturer.

  8. Detector simulation needs for detector designers

    International Nuclear Information System (INIS)

    Hanson, G.G.

    1987-11-01

    Computer simulation of the components of SSC detectors and of the complete detectors will be very important for the designs of the detectors. The ratio of events from interesting physics to events from background processes is very low, so detailed understanding of detector response to the backgrounds is needed. Any large detector for the SSC will be very complex and expensive and every effort must be made to design detectors which will have excellent performance and will not have to undergo major rebuilding. Some areas in which computer simulation is particularly needed are pattern recognition in tracking detectors and development of shower simulation code which can be trusted as an aid in the design and optimization of calorimeters, including their electron identification performance. Existing codes require too much computer time to be practical and need to be compared with test beam data at energies of several hundred GeV. Computer simulation of the processing of the data, including electronics response to the signals from the detector components, processing of the data by microprocessors on the detector, the trigger, and data acquisition will be required. In this report we discuss the detector simulation needs for detector designers

  9. A surface barrier detector for simultaneous detection of α and β particles

    International Nuclear Information System (INIS)

    Shiraishi, Fumio

    1981-01-01

    Semiconductor detectors are indispensable as the solid detectors with high energy resolution. Ge detectors are used for gamma-ray spectroscopy and its applied fields, while Si detectors are used as the detectors for charged particles such as α and β rays and low energy X-ray. In this paper, it is reported that the Si detector developed in the author's laboratory is suitable to monitor very weak radioactivity. The Si detector is a rectifier, but in order to capture radiation, it has large area and increased thickness, and a window is provided for incident charged particles. The Si detectors are classified into three types according to the manufacturing methods, namely surface barrier type, PN joint type and Li drift type. The Si detector introduced here is of surface barrier type, but it is characterized by the use of P-type Si with superhigh purity. The method of manufacturing this detector, its specifications and characteristics are described. Because of the surface barrier type, it can be produced simply in short time, and the yield of products is good. The stability is good, and the sensitivity is high, accordingly very weak radioactivity can be measured. As the examples of measurements, the results of uranium ore and fertilizer on the market are compared. Also the utilization as surface contamination meters is explained. (Kako, I.)

  10. Proton induced target fragmentation studies on solid state nuclear track detectors using Carbon radiators

    Science.gov (United States)

    Szabó, J.; Pálfalvi, J. K.; Strádi, A.; Bilski, P.; Swakoń, J.; Stolarczyk, L.

    2018-04-01

    One of the limiting factors of an astronaut's career is the dose received from space radiation. High energy protons, being the main components of the complex radiation field present on a spacecraft, give a significant contribution to the dose. To investigate the behavior of solid state nuclear track detectors (SSNTDs) if they are irradiated by such particles, SSNTD stacks containing carbon blocks were exposed to high energy proton beams (70, 100, 150 and 230 MeV) at the Proteus cyclotron, IFJ PAN -Krakow. The incident protons cannot be detected directly; however, tracks of secondary particles, recoils and fragments of the constituent atoms of the detector material and of the carbon radiator are formed. It was found that as the proton energy increases, the number of tracks induced in the PADC material by secondary particles decreases. From the measured geometrical parameters of the tracks the linear energy transfer (LET) spectrum and the dosimetric quantities were determined, applying appropriate calibration. In the LET spectra the LET range of the most important secondary particles could be identified and their abundance showed differences in the spectra if the detectors were short or long etched. The LET spectra obtained on the SSNTDs irradiated by protons were compared to LET spectra of detectors flown on the International Space Station (ISS): they were quite similar, resulting in a quality factor difference of only 5%. Thermoluminescent detectors (TLDs) were applied in each case to measure the dose from primary protons and other lower LET particles present in space. Comparing and analyzing the results of the TLD and SSNTD measurements, it was obtained that proton induced target fragments contributed to the total absorbed dose in 3.2% and to the dose equivalent in 14.2% in this particular space experiment.

  11. Particle Identification in Cherenkov Detectors using Convolutional Neural Networks

    CERN Document Server

    Theodore, Tomalty

    2016-01-01

    Cherenkov detectors are used for charged particle identification. When a charged particle moves through a medium faster than light can propagate in that medium, Cherenkov radiation is released in the shape of a cone in the direction of movement. The interior of the Cherenkov detector is instrumented with PMTs to detect this Cherenkov light. Particles, then, can be identified by the shapes of the images on the detector walls.

  12. Directional epithermal neutron detector

    International Nuclear Information System (INIS)

    Givens, W.W.; Mills, W.R. Jr.

    1986-01-01

    A borehole tool for epithermal neutron die-away logging of subterranean formations surrounding a borehole is described which consists of: (a) a pulsed source of fast neutrons for irradiating the formations surrounding a borehole, (b) at least one neutron counter for counting epithermal neutrons returning to the borehole from the irradiated formations, (c) a neutron moderating material, (d) an outer thermal neutron shield providing a housing for the counter and the moderating material, (e) an inner thermal neutron shield dividing the housing so as to provide a first compartment bounded by the inner thermal neutron shield and a first portion of the outer thermal neutron shield and a second compartment bounded by the inner thermal neutron shield and a second portion of the outer thermal neutron shield, the counter being positioned within the first compartment and the moderating material being positioned within the second compartment, and (f) means for positioning the borehole tool against one side of the borehole wall and azimuthally orienting the borehole tool such that the first chamber is in juxtaposition with the borehole wall, the formation epithermal neutrons penetrating into the first chamber through the first portion of the outer thermal neutron shield are detected by the neutron counter for die-away measurement, thereby maximizing the directional sensitivty of the neutron counter to formation epithermal neutrons, the borehole fluid epithermal neutrons penetrating into the second chamber through the second chamber through the second portion of the outer thermal neutron shield are largely slowed down and lowered in energy by the moderating material and absorbed by the inner thermal neutron shield before penetrating into the first chamber, thereby minimizing the directional sensitivity of the neutron counter to borehole fluid epithermal neutrons

  13. Photoacoustic-based detector for infrared laser spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, L.; Palzer, S., E-mail: stefan.palzer@imtek.uni-freiburg.de [Department of Microsystems Engineering-IMTEK, Laboratory for Gas Sensors, University of Freiburg, Georges-Köhler-Allee 102, Freiburg 79110 (Germany)

    2016-07-25

    In this contribution, we present an alternative detector technology for use in direct absorption spectroscopy setups. Instead of a semiconductor based detector, we use the photoacoustic effect to gauge the light intensity. To this end, the target gas species is hermetically sealed under excess pressure inside a miniature cell along with a MEMS microphone. Optical access to the cell is provided by a quartz window. The approach is particularly suitable for tunable diode laser spectroscopy in the mid-infrared range, where numerous molecules exhibit large absorption cross sections. Moreover, a frequency standard is integrated into the method since the number density and pressure inside the cell are constant. We demonstrate that the information extracted by our method is at least equivalent to that achieved using a semiconductor-based photon detector. As exemplary and highly relevant target gas, we have performed direct spectroscopy of methane at the R3-line of the 2v{sub 3} band at 6046.95 cm{sup −1} using both detector technologies in parallel. The results may be transferred to other infrared-active transitions without loss of generality.

  14. Study of the use of a Phoswich detector for aerial radiometric surveys

    International Nuclear Information System (INIS)

    Schneid, E.J.; Lagin, L.J.

    1981-09-01

    Large volume, actively shielded Phoswich detector configurations were investigated for application in airborne radiometric survey systems in order to increase the sensitivity to ground-level potassium, uranium, and thorium compared to conventional NaI detectors of similar sizes. One Phoswich configuration was fabricated and flight tested. The flight measurements with the Phoswich detector and a conventional NaI detector utilized the Bendix Field Engineering Corporation - US Department of Energy/Grand Junction Office Walker Field Aerial Radiometric Survey Calibration Facility, the DOE dynamic test range, and a region in the southwest portion of the Lubbock, Texas, Quadrangle. The tests demonstrated that the Phoswich detector can function in an operational environment and does provide greater sensitivity to ground-level potassium, uranium, and thorium concentration than the conventional NaI detector. The multicrystal configuration for the Phoswich detector provided the capability to simultaneously measure the atmospheric radon background without the need of heavy lead shields. The flight tests indicated that the Phoswich detector has directional discrimination capability not available with conventional NaI detector systems. This directional capability can be used to distinguish the location, relative to the aircraft, of localized strong sources of radiation

  15. Lyman-alpha detector designed for rocket measurements of the direct solar radiation at 121.5 nm

    International Nuclear Information System (INIS)

    Guineva, V.; Tashev, V.; Witt, G.; Gumbel, J.; Khaplanov, M.

    2007-01-01

    Rocket measurements of the direct Lyman-alpha radiation penetrating in the atmosphere were planned during the HotPay I rocket experiment, June 2006, Project ASLAF (Attenuation of the Solar Lyman-Alpha Flux), Andoya Rocket Range (ARR), Norway. The basic goal of ASLAF project was the study of the processes in the summer mesosphere and thermosphere (up to 110 km), at high latitudes using the Lyman-alpha measurements. The resonance transition 2 P- 2 S of the atomic hydrogen (Lyman-alpha emission) is the strongest and most conspicuous feature in the solar EUV spectrum. Due to the favourable circumstance, that the Lyman-alpha wavelength (121.5 nm) coincides with a minimum of the O 2 absorption spectrum, the direct Lyman-alpha radiation penetrates well in the mesosphere. The Lyman-alpha radiation is the basic agent of the NO molecules ionization, thus generating the ionospheric D-layer, and of the water vapour photolysis, being one of the main H 2 O loss processes. The Lyman-alpha radiation transfer depends on the resonance scattering from the hydrogen atoms in the atmosphere and on the O 2 absorption. Since the Lyman-alpha extinction in the atmosphere is a measure for the column density of the oxygen molecules, the atmospheric temperature profile can be calculated thereof. The detector of solar Lyman-alpha radiation was manufactured in the Stara Zagora Department of the Solar-Terrestrial Influences Laboratory (STIL). Its basic part is an ionization chamber, filled in with NO. A 60 V power supply is applied to the chamber. The produced photoelectric current from the sensor is fed to a 2-channels amplifier, providing an analogue signal. The characteristics of the Lyman-alpha detector were studied. It passed successfully all tests and the results showed that the instrument could be used in rocket experiments to measure the Lyman-alpha flux. From the measurements of the detector, the Lyman-alpha vertical profile can be obtained. The forthcoming scientific data analysis will

  16. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector

    International Nuclear Information System (INIS)

    Seo, B.K.; Lee, D.W.; Lee, K.Y.; Yoon, Y.Y.

    2001-01-01

    A simple but precise detection method was studied for the determination of natural radionuclides using a conventional HPGe detector. A new aluminium beaker instead of a plastic Marinelli beaker was constructed and examined to reach radioactive equilibrium conditions between radon and its daughter elements without the escape of gaseous radon. Using this beaker fifteen natural radionuclides from three natural decay series could be determined by direct γ-ray measurement and sixteen radionuclides could be determined indirectly after radioactive equilibrium had been reached. Analytical results from ground water were compared with those from conventional α spectroscopy and the results agreed well within 12% difference. Nitrogen gas purge was used to replace the surrounding air of the detector to obtain a stable background and reducing the interference of radon daughter nuclides in the atmosphere. The use of nitrogen purging and the aluminium Marinelli beaker results in an approximately tenfold increase of sensitivity and a decrease of the detection limit of 226 Ra to about 0.74 Bq kg -1 in soil samples. (orig.)

  17. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector.

    Science.gov (United States)

    Seo, B K; Lee, K Y; Yoon, Y Y; Lee, D W

    2001-06-01

    A simple but precise detection method was studied for the determination of natural radionuclides using a conventional HPGe detector. A new aluminium beaker instead of a plastic Marinelli beaker was constructed and examined to reach radioactive equilibrium conditions between radon and its daughter elements without the escape of gaseous radon. Using this beaker fifteen natural radionuclides from three natural decay series could be determined by direct gamma-ray measurement and sixteen radionuclides could be determined indirectly after radioactive equilibrium had been reached. Analytical results from ground water were compared with those from conventional alpha spectroscopy and the results agreed well within 12% difference. Nitrogen gas purge was used to replace the surrounding air of the detector to obtain a stable background and reducing the interference of radon daughter nuclides in the atmosphere. The use of nitrogen purging and the aluminium Marinelli beaker results in an approximately tenfold increase of sensitivity and a decrease of the detection limit of 226Ra to about 0.74 Bq kg(-1) in soil samples.

  18. A Figure-of-Merit for Beta Cell Detector Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Foxe, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Miller, Brian W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Suarez, Rey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hayes, James C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-02

    In order to decrease the minimum detectable activities (MDAs) of beta-gamma radioxenon detectors, it is important to increase the ability to resolve the individual isotopes. One proposed method for doing this is to increase the energy resolution of the beta cell through the use of silicon detectors. While silicon detectors can improve the energy resolution, it is accompanied with a decrease in detection efficiency compared to plastic scintillator beta cells. Due to the uncertainty on the impact of the competing variables, we have developed a figure-of-merit (FOM) capable of determining the impact of detector parameters on the MDAs. By utilizing the FOM to analyze different detectors, we are able to directly compare current and future detectors and estimate their impact on the radioxenon MDAs.

  19. The silicon shower maximum detector for the STIC

    International Nuclear Information System (INIS)

    Alvsvaag, S.J.; Maeland, O.A.; Klovning, A.

    1995-01-01

    The structure of a shashlik calorimeter allows the insertion of tracking detectors within the longitudinal sampling to improve the accuracy in the determination of the direction of the showering particle and the e/π separation ability. The new forward calorimeter of the DELPHI detector has been equipped with two planes of silicon pad detectors respectively after 4 and 7.4 radiation lengths. The novelty of these silicon detectors is that to cope with the shashlik readout fibers, they had to incorporate 1.4 mm holes every cm 2 . The detector consists of circular strips with a radial pitch of 1.7 mm and an angular granularity of 22.5 , read out by means of the MX4 preamplifier. The preamplifier is located at 35 cm from the silicon detector and the signal is carried by Kapton cables bonded to the detector. The matching to the MX4 input pitch of 44 μm was made by a specially developed fanin hybrid. (orig.)

  20. Development of Small-Pixel CZT Detectors for Future High-Resolution Hard X-ray Missions

    Science.gov (United States)

    Beilicke, Matthias

    Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolutions of between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of hard X-ray telescopes will require pixelated hard X- ray detectors with pixels on a grid with a lattice constant of between 120 and 240 um. Additional detector requirements include a low energy threshold of less than 5 keV and an energy resolution of less than 1 keV. The science drivers for a high angular-resolution hard X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, AGN feedback, and the behavior of matter at very high densities. We propose a R&D research program to develop, optimize and study the performance of 100-200 um pixel pitch CdTe and Cadmium Zinc Telluride (CZT) detectors of 1-2 mm thickness. Our program aims at a comparison of the performance achieved with CdTe and CZT detectors, and the optimization of the pixel, steering grid, and guard ring anode patterns. Although these studies will use existing ASICs (Application Specific Integrated Circuits), our program also includes modest funds for the development of an ultra-low noise ASIC with a 2-D grid of readout pads that can be directly bonded to the 100-200 um pixel pitch CdTe and CZT detectors. The team includes the Washington University group (Prof. M. Beilicke and Co-I Prof. H.S.W. Krawczynski et al.), and co-investigator G. De Geronimo at Brookhaven National Laboratory (BNL). The Washington University group has a 10 year track record of innovative CZT detector R&D sponsored by the NASA Astronomy and Physics Research and Analysis (APRA) program. The accomplishments to date include the development of CZT detectors with pixel pitches between 350 um and 2.5 mm for the ProtoExist, EXIST, and X-Calibur hard X-ray missions with some of the best

  1. Innovative mid-infrared detector concepts

    Science.gov (United States)

    Höfling, Sven; Pfenning, Andreas; Weih, Robert; Ratajczak, Albert; Hartmann, Fabian; Knebl, Georg; Kamp, Martin; Worschech, Lukas

    2016-09-01

    Gas sensing is a key technology with applications in various industrial, medical and environmental areas. Optical detection mechanisms allow for a highly selective, contactless and fast detection. For this purpose, rotational-vibrational absorption bands within the mid infrared (MIR) spectral region are exploited and probed with appropriate light sources. During the past years, the development of novel laser concepts such as interband cascade lasers (ICLs) and quantum cascade lasers (QCLs) has driven a continuous optimization of MIR laser sources. On the other hand side, there has been relatively little progress on detectors in this wavelength range. Here, we study two novel and promising GaSb-based detector concepts: Interband cascade detectors (ICD) and resonant tunneling diode (RTD) photodetectors. ICDs are a promising approach towards highly sensitive room temperature detection of MIR radiation. They make use of the cascading scheme that is enabled by the broken gap alignment of the two binaries GaSb and InAs. The interband transition in GaSb/InAs-superlattices (SL) allows for normal incidence detection. The cut-off wavelength, which determines the low energy detection limit, can be engineered via the SL period. RTD photodetectors act as low noise and high speed amplifiers of small optically generated electrical signals. In contrast to avalanche photodiodes, where the gain originates from multiplication due to impact ionization, in RTD photodetectors a large tunneling current is modulated via Coulomb interaction by the presence of photogenerated minority charge carriers. For both detector concepts, first devices operational at room temperature have been realized.

  2. Characterizing the response of a scintillator-based detector to single electrons

    International Nuclear Information System (INIS)

    Sang, Xiahan; LeBeau, James M.

    2016-01-01

    Here we report the response of a high angle annular dark field scintillator-based detector to single electrons. We demonstrate that care must be taken when determining the single electron intensity as significant discrepancies can occur when quantifying STEM images with different methods. To account for the detector response, we first image the detector using very low beam currents (∼8 fA), and subsequently model the interval between consecutive single electrons events. We find that single electrons striking the detector present a wide distribution of intensities, which we show is not described by a simple function. Further, we present a method to accurately account for the electrons within the incident probe when conducting quantitative imaging. The role detector settings play on determining the single electron intensity is also explored. Finally, we extend our analysis to describe the response of the detector to multiple electron events within the dwell interval of each pixel. - Highlights: • We show that the statistical description of single electron response of scintillator based detectors can be measured using a combination of small beam currents and short dwell times. • The average intensity from the probability distribution function can be used to normalize STEM images regardless of beam current and contrast settings. • We obtain consistent QSTEM normalization results from the single electron method and the conventional detector scan method.

  3. Imaging monolithic silicon detector telescopes

    International Nuclear Information System (INIS)

    Amorini, F.; Sipala, V.; Cardella, G.; Boiano, C.; Carbone, B.; Cosentino, L.; Costa, E.; Di Pietro, A.; Emanuele, U.; Fallica, G.; Figuera, P.; Finocchiaro, P.; La Guidara, E.; Marchetta, C.; Pappalardo, A.; Piazza, A.; Randazzo, N.; Rizzo, F.; Russo, G.V.; Russotto, P.

    2008-01-01

    We show the results of some test beams performed on a new monolithic strip silicon detector telescope developed in collaboration with the INFN and ST-microelectronics. Using an appropriate design, the induction on the ΔE stages, generated by the charge released in the E stage, was used to obtain the position of the detected particle. The position measurement, together with the low threshold for particle charge identification, allows the new detector to be used for a large variety of applications due to its sensitivity of only a few microns measured in both directions

  4. The two sides of silicon detectors

    International Nuclear Information System (INIS)

    Devine, S.R.

    2001-10-01

    Results are presented on in situ irradiation of silicon detector's at cryogenic temperature. The results show that irradiation at cryogenic temperatures does not detrimentally effect a silicon detectors performance when compared to its irradiation at room temperature. Operation of silicon devices at cryogenic temperatures offers the advantage of reducing radiation-induced leakage current to levels of a few pA, while at 130K the Lazarus Effect plays an important role i.e. minimum voltage required for full depletion. Performing voltage scans on a 'standard' silicon pad detector pre- and post annealing, the charge collection efficiency was found to be 60% at 200V and 95% at 200V respectively. Time dependence measurements are presented, showing that for a dose of 6.5x10 14 p/cm 2 (450GeV protons) the time dependence of the charge collection efficiency is negligible. However, for higher doses, 1.2x10 15 p/cm 2 , the charge collection efficiency drops from an initial measured value of 67% to a stable value of 58% over a period of 15 minutes for reversed biased diodes. An analysis of the 'double junction' effect is also presented. A comparison between the Transient Current Technique and an X-ray technique is presented. The double junction has been observed in p + /n/n + silicon detectors after irradiation beyond 'type inversion', corresponding to a fluence equivalent to ∼3x10 13 cm -2 1MeV neutrons, producing p + /p/n + and essentially two p-n junctions within one device. With increasing bias voltage, as the electric field is extending into the detector bulk from opposite sides of the silicon detector, there are two distinct depletion regions that collect charge signal independently. Summing the signal charge from the two regions, one is able to reconstruct the initial energy of the incident particle. From Transient Current measurements it is apparent that E-field manipulation is possible by excess carrier injection, enabling a high enough E-field to extend across the

  5. Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, D.; Imme, G.; Catalano, R. [Dipartimento di Fisica e Astronomia, Universita degli Studi di Catania, via S. Sofia, 64- 95123 Catania (Italy); Istituto Nazionale di Fisica Nucleare - Sezione di Catania, via S. Sofia, 64- 95123 Catania (Italy); Aranzulla, M. [Istituto Nazionale Geofisica e Vulcanologia - Sezione di Catania, piazza Roma, 2- 95127 Catania (Italy); Tazzer, A. L. Rosselli; Mangano, G. [Dipartimento di Fisica e Astronomia, Universita degli Studi di Catania, via S. Sofia, 64- 95123 Catania (Italy)

    2011-12-13

    Solid Nuclear Track Detectors (SNTDs), CR-39 type, are usually adopted to monitor radon gas concentrations. In order to characterize the detectors according to track geometrical parameters, detectors were irradiated inside a vacuum chamber by alpha particles at twelve energy values, obtained by different Mylar foils in front of a {sup 241}Am source. The alpha energy values were verified using a Si detector. After the exposure to the alpha particles, the detectors were chemically etched to enlarge the tracks, which were then analyzed by means of a semiautomatic system composed of an optical microscope equipped with a CCD camera connected to a personal computer to store images. A suitable routine analyzed the track parameters: major and minor axis length and mean grey level, allowing us to differentiate tracks according to the incident alpha energy and then to individuate the discrimination factors for radon alpha tracks. The combined use of geometrical and optical parameters allows one to overcome the ambiguity in the alpha energy determination due to the non-monotonicity of each parameter versus energy. After track parameter determination, a calibration procedure was performed by means of a radon chamber. The calibration was verified through an inter-comparing survey.

  6. A calibration method for phoswich detectors

    CERN Document Server

    Gawlikowicz, W; Schröder, W U

    2002-01-01

    A new method of particle identification and energy calibration is proposed for phoswich detectors consisting of a fast plastic scintillator optically coupled to a CsI(Tl) crystal. In this method, functional relationships between integrated yields of three properly selected portions of the observed composite light output signal are parameterized in terms of three physical components (overlapping in time) of this signal. Then, a complete set of calibration constants is derived, linking these integrated partial yields to particle atomic numbers (Z) and energies (E). The calibration is based on the correlations between partial yields observed in actual data from the physics or 'production' runs, and energy deposits calculated for detector elements. The method is found suitable for a wide range of incident particle species and energies, largely eliminating the need for costly and time-consuming conventional calibration experiments with a variety of beams, targets, and bombarding energies.

  7. MUST detector

    International Nuclear Information System (INIS)

    Blumenfeld, Y.; Auger, F.; Sauvestre, J.E.

    1999-01-01

    The IPN-Orsay, in collaboration with the SPhN-Saclay and the DPTA Bruyeres, has built an array of 8 telescopes based on Si-strip technology for the study of direct reactions induced by radioactive beams. The detectors are described, along with the compact high density VXI electronics and the stand-alone data acquisition system developed in the laboratory. One telescope was tested using an 40 Ar beam and the measured performances are discussed. (authors)

  8. High performance visual display for HENP detectors

    International Nuclear Information System (INIS)

    McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations

  9. Direct single electron detection with a CMOS detector for electron microscopy

    International Nuclear Information System (INIS)

    Faruqi, A.R.; Henderson, R.; Pryddetch, M.; Allport, P.; Evans, A.

    2005-01-01

    We report the results of an investigation into the use of a monolithic active pixel sensor (MAPS) for electron microscopy. MAPS, designed originally for astronomers at the Rutherford Appleton Laboratories, was installed in a 120 kV electron microscope (Philips CM12) at the MRC Laboratory in Cambridge for tests which included recording single electrons at 40 and 120 keV, and measuring signal-to-noise ratio (SNR), spatial resolution and radiation sensitivity. Our results show that, due to the excellent SNR and resolution, it is possible to register single electrons. The radiation damage to the detector is apparent with low doses and gets progressively greater so that its lifetime is limited to 600,000-900,000 electrons/pixel (very approximately 10-15 krad). Provided this detector can be radiation hardened to reduce its radiation sensitivity several hundred fold and increased in size, it will provide excellent performance for all types of electron microscopy

  10. Comparison of modeled and measured performance of a GSO crystal as gamma detector

    International Nuclear Information System (INIS)

    Parno, D.S.; Friend, M.; Mamyan, V.; Benmokhtar, F.; Camsonne, A.; Franklin, G.B.; Paschke, K.; Quinn, B.

    2013-01-01

    We have modeled, tested, and installed a large, cerium-activated Gd 2 SiO 5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well

  11. Prediction of Safety Incidents

    Data.gov (United States)

    National Aeronautics and Space Administration — Safety incidents, including injuries, property damage and mission failures, cost NASA and contractors thousands of dollars in direct and indirect costs. This project...

  12. NEW LENSLET BASED IFS WITH HIGH DETECTOR PIXEL EFFICIENCY

    Science.gov (United States)

    Gong, Qian

    2018-01-01

    Three IFS types currently used for optical design are: lenslet array, imager slicer, and lenslet array and fiber combined. Lenslet array based Integral Field Spectroscopy (IFS) is very popular for many astrophysics applications due to its compactness, simplicity, as well as cost and mass savings. The disadvantage of lenslet based IFS is its low detector pixel efficiency. Enough spacing is needed between adjacent spectral traces in cross dispersion direction to avoid wavelength cross-talk, because the same wavelength is not aligned to the same column on detector. Such as on a recent exoplanet coronagraph instrument study to support the coming astrophysics decadal survey (LUVOIR), to cover a 45 λ/D Field of View (FOV) with a spectral resolving power of 200 at shortest wavelength, a 4k x 4k detector array is needed. This large format EMCCD pushes the detector into technology development area with a low TRL. Besides the future mission, it will help WFIRST coronagraph IFS by packing all spectra into a smaller area on detector, which will reduce the chance for electrons to be trapped in pixels, and slow the detector degradation during the mission.The innovation we propose here is to increase the detector packing efficiency by grouping a number of lenslets together to form many mini slits. In other words, a number of spots (Point Spread Function at lenslet focus) are aligned into a line to resemble a mini slit. Therefore, wavelength cross-talk is no longer a concern anymore. This combines the advantage of lenslet array and imager slicer together. The isolation rows between spectral traces in cross dispersion direction can be reduced or removed. So the packing efficiency is greatly increased. Furthermore, the today’s microlithography and etching technique is capable of making such a lenslet array, which will relax the detector demand significantly. It will finally contribute to the habitable exoplanets study to analyzing their spectra from direct images. Detailed theory

  13. New detectors technology for radiology imaging

    International Nuclear Information System (INIS)

    Cuzin, M.; Peyret, O.

    1998-01-01

    We summarize the main parameters which describes the radiological image at first and the advantages of pixel detectors. All detectors converts X-rays in charges either with an intermediate step with light or directly in a semi-conductor media. That is true for tomography which is the first domain where digital processing have been taken in account and for radiology where flat panel are now proposed to radiologists. Nevertheless, luminescent stimulated screens are a good way to prepare users with digital radiography. As such technique is not valuable for dynamic acquisition, we describe systems which used standard luminescent screens with CCD cameras or with IIR. Some description and comparison of flat panel independent pixel detectors are given. (authors)

  14. Influence functionals and the accelerating detector

    International Nuclear Information System (INIS)

    Anglin, J.R.

    1993-01-01

    The influence functional is derived for a massive scalar field in the ground state, coupled to a uniformly accelerating DeWitt monopole detector in (D+1)-dimensional Minkowski space. This confirms the local nature of the Unruh effect, and provides an exact solution to the problem of the accelerating detector without invoking a nonstandard quantization. A directional detector is presented which is efficiently decohered by the scalar field vacuum, and which illustrates an important difference between the quantum mechanics of inertial and noninertial frames. From the results of these calculations, some comments are made regarding the possibility of establishing a quantum equivalence principle, so that the Hawking effect might be derived from the Unruh effect

  15. Determining dose rate with a semiconductor detector - Monte Carlo calculations of the detector response

    Energy Technology Data Exchange (ETDEWEB)

    Nordenfors, C

    1999-02-01

    To determine dose rate in a gamma radiation field, based on measurements with a semiconductor detector, it is necessary to know how the detector effects the field. This work aims to describe this effect with Monte Carlo simulations and calculations, that is to identify the detector response function. This is done for a germanium gamma detector. The detector is normally used in the in-situ measurements that is carried out regularly at the department. After the response function is determined it is used to reconstruct a spectrum from an in-situ measurement, a so called unfolding. This is done to be able to calculate fluence rate and dose rate directly from a measured (and unfolded) spectrum. The Monte Carlo code used in this work is EGS4 developed mainly at Stanford Linear Accelerator Center. It is a widely used code package to simulate particle transport. The results of this work indicates that the method could be used as-is since the accuracy of this method compares to other methods already in use to measure dose rate. Bearing in mind that this method provides the nuclide specific dose it is useful, in radiation protection, since knowing what the relations between different nuclides are and how they change is very important when estimating the risks

  16. Newtonian noise cancellation in tensor gravitational wave detector

    International Nuclear Information System (INIS)

    Paik, Ho Jung; Harms, Jan

    2016-01-01

    Terrestrial gravity noise produced by ambient seismic and infrasound fields poses one of the main sensitivity limitations in low-frequency ground-based gravitational-wave (GW) detectors. This noise needs to be suppressed by 3-5 orders of magnitude in the frequency band 10 mHz to 1 Hz, which is extremely challenging. We present a new approach that greatly facilitates cancellation of gravity noise in full-tensor GW detectors. It makes explicit use of the direction of propagation of a GW, and can therefore either be implemented in directional searches for GWs or in observations of known sources. We show that suppression of the Newtonian-noise foreground is greatly facilitated using the extra strain channels in full-tensor GW detectors. Only a modest number of auxiliary, high-sensitivity environmental sensors is required to achieve noise suppression by a few orders of magnitude. (paper)

  17. Measurement of the Muon Neutrino Inclusive Charged Current Cross Section on Iron using the MINOS Detector

    Energy Technology Data Exchange (ETDEWEB)

    Loiacono, Laura Jean [Univ. of Texas, Austin, TX (United States)

    2010-05-01

    The Neutrinos at the Main Injector (NuMI) facility at Fermi National Accelerator Laboratory (FNAL) produces an intense muon neutrino beam used by the Main Injector Neutrino Oscillation Search (MINOS), a neutrino oscillation experiment, and the Main INjector ExpeRiment v-A, (MINERv A), a neutrino interaction experiment. Absolute neutrino cross sections are determined via σv = N vv , where the numerator is the measured number of neutrino interactions in the MINOS Detector and the denominator is the flux of incident neutrinos. Many past neutrino experiments have measured relative cross sections due to a lack of precise measurements of the incident neutrino flux, normalizing to better established reaction processes, such as quasielastic neutrino-nucleon scattering. But recent measurements of neutrino interactions on nuclear targets have brought to light questions about our understanding of nuclear effects in neutrino interactions. In this thesis the vμ inclusive charged current cross section on iron is measured using the MINOS Detector. The MINOS detector consists of alternating planes of steel and scintillator. The MINOS detector is optimized to measure muons produced in charged current vμ interactions. Along with muons, these interactions produce hadronic showers. The neutrino energy is measured from the total energy the particles deposit in the detector. The incident neutrino flux is measured using the muons produced alongside the neutrinos in meson decay. Three ionization chamber monitors located in the downstream portion of the NuMI beamline are used to measure the muon flux and thereby infer the neutrino flux by relation to the underlying pion and kaon meson flux. This thesis describes the muon flux instrumentation in the NuMI beam, its operation over the two year duration of this measurement, and the techniques used to derive the neutrino flux.

  18. Dark-field image contrast in transmission scanning electron microscopy: Effects of substrate thickness and detector collection angle

    Energy Technology Data Exchange (ETDEWEB)

    Woehl, Taylor, E-mail: tjwoehl@umd.edu; Keller, Robert

    2016-12-15

    An annular dark field (ADF) detector was placed beneath a specimen in a field emission scanning electron microscope operated at 30 kV to calibrate detector response to incident beam current, and to create transmission images of gold nanoparticles on silicon nitride (SiN) substrates of various thicknesses. Based on the linear response of the ADF detector diodes to beam current, we developed a method that allowed for direct determination of the percentage of that beam current forward scattered to the ADF detector from the sample, i.e. the transmitted electron (TE) yield. Collection angles for the ADF detector region were defined using a masking aperture above the detector and were systematically varied by changing the sample to detector distance. We found the contrast of the nanoparticles, relative to the SiN substrate, decreased monotonically with decreasing inner exclusion angle and increasing substrate thickness. We also performed Monte Carlo electron scattering simulations, which showed quantitative agreement with experimental contrast associated with the nanoparticles. Together, the experiments and Monte Carlo simulations revealed that the decrease in contrast with decreasing inner exclusion angle was due to a rapid increase in the TE yield of the low atomic number substrate. Nanoparticles imaged at low inner exclusion angles (<150 mrad) and on thick substrates (>50 nm) showed low image contrast in their centers surrounded by a bright high-contrast halo on their edges. This complex image contrast was predicted by Monte Carlo simulations, which we interpreted in terms of mixing of the nominally bright field (BF) and ADF electron signals. Our systematic investigation of inner exclusion angle and substrate thickness effects on ADF t-SEM imaging provides fundamental understanding of the contrast mechanisms for image formation, which in turn suggest practical limitations and optimal imaging conditions for different substrate thicknesses. - Highlights: • Developed a

  19. A new parameter in the electrochemical etching of polymer track detectors

    International Nuclear Information System (INIS)

    Sohrabi, M.; Katouzi, M.

    1993-01-01

    It was discovered that the pressure applied to the electrochemical etching (ECE) chamber system and in turn to washers holding the detector tight in place between two semi-chambers has a direct effect on the internal heating and time to breakdown of the polymer detector. The effect was found to be dependent on the type, material, shape and size of the washers holding the detector in place under pressure. To verify such parameters, a pressure ECE chamber (PECE) with measurable and reproducible pressure was designed and constructed. Three types of rubber washers, such as ''O'' rings, flat rings and sheets as well as polycarbonate (PC) detectors glued directly between two semi-syringes, were used. Flat rubber sheets were shown to have relatively minor effects on the internal heating rate and are recommended. The effect seems to be due to forced vibrations of the detector under an electric field, the frequency of which depends on the degree to which the detector is stretched under pressure, like winding the strings of a musical instrument. The results of the above studies are presented and discussed. (orig.)

  20. The study of response of wide band gap semiconductor detectors using the Geant4

    Directory of Open Access Journals (Sweden)

    Hussain Riaz

    2014-01-01

    Full Text Available The energy dependence on the intrinsic efficiency, absolute efficiency, full energy peak absolute efficiency and peak-to-total ratio have been studied for various wide band gap semiconductor detectors using the Geant4 based Monte Carlo simulations. The detector thickness of 1-4 mm and the area in 16-100 mm2 range were considered in this work. In excellent agreement with earlier work (Rybka et al., [20], the Geant4 simulated values of detector efficiencies have been found to decrease with incident g-ray energy. Both for the detector thickness and the detector area, the increasing trends have been observed for total efficiency as well as for full-energy peak efficiency in 0.1 MeV-50 MeV range. For Cd1-xZnxTe, the detector response remained insensitive to changes in relative proportions of Zn. For various wide band gap detectors studied in this work, the detection efficiency of TlBr was found highest over the entire range of energy, followed by the HgI2, CdTe, and then by CZT.

  1. SuperCDMS Underground Detector Fabrication Facility

    Energy Technology Data Exchange (ETDEWEB)

    Platt, M.; Mahapatra, R.; Bunker, Raymond A.; Orrell, John L.

    2018-03-01

    The SuperCDMS SNOLAB dark matter experiment processes Ge and Si crystals into fully tested phonon and ionization detectors at surface fabrication and test facilities. If not mitigated, it is anticipated that trace-level production of radioisotopes in the crystals due to exposure to cosmic rays at (or above) sea level will result in the dominant source of background events in future dark matter searches using the current SuperCDMS detector technology. Fabrication and testing of detectors in underground facilities shielded from cosmic radiation is one way to directly reduce production of trace levels of radioisotopes, thereby improving experimental sensitivity for the discovery of dark matter beyond the level of the current experiment. In this report, we investigate the cost and feasibility to establish a complete detector fabrication processing chain in an underground location to mitigate cosmogenic activation of the Ge and Si detector substrates. For a specific and concrete evaluation, we explore options for such a facility located at SNOLAB, an underground laboratory in Sudbury, Canada hosting the current and future experimental phases of SuperCDMS.

  2. Optimization of the energy resolution and of the radioactive background rejection for ionization-heat detectors equipped with thermometric thin films for the direct WIMPs detection

    International Nuclear Information System (INIS)

    Dolgorouky, Y.W.

    2008-09-01

    The EDELWEISS experiment aims at the direct detection of WIMPs as possible candidates for dark matter. It uses heat-and-ionization detectors that can discriminate these particles from the radioactive background. To date, this method is limited by events with incomplete charge collection that occur just beneath the detectors electrodes. In order to identify and reject these undesirable events, we have developed detectors equipped with thin films used both as thermometers - and hence sensitive to the transient athermal regime - and as electrodes for the charge collection. This thesis focuses on the optimization of such thin films regarding surface events rejection and on the modelling of the physical processes enabling this identification. The optimization must both maximize the fiducial volume and conserve an energy resolution such that the recoil energy threshold is of the order of 30 keV. Our work explores four generations of detectors each of which corresponds to successive evolutions in their conception. In all cases, the electrode-thermometer is an amorphous Anderson insulator NbSi thin film polarized by two interleaved comb-shaped niobium electrodes. In spite of constant progress in the successive detectors performances, the latest generation does not display the performances required for the EDELWEISS II experiment. Our work has shown the difficulty of the transient thermal signal modelling due to the complex contribution of the charge collection. This works has lead to new ideas regarding the detectors configuration, so that the athermal regime can be optimized to enhance both the rejection capability and the resolution. (author)

  3. Evaluation of In-Vacuum Imaging Plate Detector for X-Ray Diffraction Microscopy

    International Nuclear Information System (INIS)

    Nishino, Yoshinori; Takahashi, Yukio; Yamamoto, Masaki; Ishikawa, Tetsuya

    2007-01-01

    We performed evaluation tests of a newly developed in-vacuum imaging plate (IP) detector for x-ray diffraction microscopy. IP detectors have advantages over direct x-ray detection charge-coupled device (CCD) detectors, which have been commonly used in x-ray diffraction microscopy experiments, in the capabilities for a high photon count and for a wide area. The detector system contains two IPs to make measurement efficient by recording data with the one while reading or erasing the other. We compared speckled diffraction patterns of single particles taken with the IP and a direct x-ray detection CCD. The IP was inferior to the CCD in spatial resolution and in signal-to-noise ratio at a low photon count

  4. Small-Scale Readout System Prototype for the STAR PIXEL Detector

    International Nuclear Information System (INIS)

    Szelezniak, Michal; Anderssen, Eric; Greiner, Leo; Matis, Howard; Ritter, Hans Georg; Stezelberger, Thorsten; Sun, Xiangming; Thomas, James; Vu, Chinh; Wieman, Howard

    2008-01-01

    Development and prototyping efforts directed towards construction of a new vertex detector for the STAR experiment at the RHIC accelerator at BNL are presented. This new detector will extend the physics range of STAR by allowing for precision measurements of yields and spectra of particles containing heavy quarks. The innermost central part of the new detector is a high resolution pixel-type detector (PIXEL). PIXEL requirements are discussed as well as a conceptual mechanical design, a sensor development path, and a detector readout architecture. Selected progress with sensor prototypes dedicated to the PIXEL detector is summarized and the approach chosen for the readout system architecture validated in tests of hardware prototypes is discussed

  5. Development of a Compact Gamma-ray Detector for a Neural-Network Radiation Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H. S.; Ha, J. H.; Lee, K. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, C. H. [Hanyang Univ., Seoul (Korea, Republic of)

    2012-03-15

    Radiation monitoring is very important to secure safety in nuclear-related facilities and against nuclear terrorism. For wide range of radiation monitoring, neutral network system of radiation detection is most efficient way. Thus, a compact radiation detector is useful to install in wide range to be concerned. A compact gamma-ray detector was fabricated by using a CsI(Tl) scintillator, which was matched with the formerly developed PIN photodiode, for a neural network radiation monitoring. At room temperature, the fabricated compact gamma-ray detector demonstrates an energy resolution of 13.3 % for 662 keV 6.9% for 1330 keV. The compactness, the low-voltage power consumption and the physical hardness are very useful features for a neural network radiation monitoring. In this study, characteristics of a fabricated compact gamma-ray detector were presented. An important aspect to consider in a neural-network radiation monitoring such as reaction probability of the fabricated compact detector for angle of incident gamma-ray was also addressed.

  6. Modelling of the small pixel effect in gallium arsenide X-ray imaging detectors

    CERN Document Server

    Sellin, P J

    1999-01-01

    A Monte Carlo simulation has been carried out to investigate the small pixel effect in highly pixellated X-ray imaging detectors fabricated from semi-insulating gallium arsenide. The presence of highly non-uniform weighting fields in detectors with a small pixel geometry causes the majority of the induced signal to be generated when the moving charges are close to the pixellated contacts. The response of GaAs X-ray imaging detectors is further complicated by the presence of charge trapping, particularly of electrons. In this work detectors are modelled with a pixel pitch of 40 and 150 mu m, and with thicknesses of 300 and 500 mu m. Pulses induced in devices with 40 mu m pixels are due almost totally to the movement of the lightly-trapped holes and can exhibit significantly higher charge collection efficiencies than detectors with large electrodes, in which electron trapping is significant. Details of the charge collection efficiencies as a function of interaction depth in the detector and of the incident phot...

  7. The detector for dark matter search

    International Nuclear Information System (INIS)

    Li Jin

    2004-01-01

    The dark matter search and dark matter detection is very importance project in Particle Physics, Astrophysics and Cosmology. The paper introduces the current status of the dark matter search in the world and points out that the development of detector with larger scale, lower threshold, very low radioactive background and building of underground laboratory is important developing direction. So far, there is no such detector and underground laboratory in our county. We should change such situation as soon as possible. (authors)

  8. Performance of the E771 RPC muon detector at Fermilab

    International Nuclear Information System (INIS)

    Cataldi, G.; Creti, P.; Elia, V.; Fiore, G.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Pinto, C.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Corti, G.

    1994-01-01

    The technique of resistive plate counters, equipped with pad readout instead of strips, has been successfully used for the first time in a high rate environment. The performance of the muon detector of E771, based on this technique, is illustrated in detail, including the dependence of the efficiency on the local rate of incident particles. (orig.)

  9. Direct reactions induced by 16O on 208Pb at high incident energy

    International Nuclear Information System (INIS)

    Mermaz, M.C.

    1978-01-01

    Direct reactions induced by 16 O mainly on 208 Pb at 20 MeV/nucleon are reviewed. The quasi-elastic transfer reaction, such as one-proton and one-neutron transfer respectively leading to 209 Bi and 209 Pb single-particle-states, is first discussed, the fragmentation of 16 O projectile on heavy targets is then envisaged. The one-nucleon transfer can be described within the framework of one-step processes using the DWBA formalism to calculate the cross sections. At high incident energy (312.6 MeV), transfer reactions involving nucleons from the deeper 1p 3/2 orbit of 16 O are kinematically favoured and well observed. At 20 MeV/A and above, a large part of the reaction cross sections seems to be due to the fragmentation of the projectile; more especially, an abrasion-ablation model have to be used in order to explain the general trend of the data (energy spectra and angular distribution)

  10. Primary Cosmic Rays Composition: Simulations and Detector Design

    International Nuclear Information System (INIS)

    Supanitsky, D.; Etchegoyen, A.; Medina, C.; Medina-Tanco, G.; Gomez Berisso, M.

    2007-01-01

    The Pierre Auger Observatory is a hybrid detector system for the detection of very high energy cosmic rays. A most difficult and important problem in these studies is the determination of the primary cosmic ray composition for which muon content in air showers appears to be one of the best parameters to discriminate between different composition types.Although the Pierre Auger surface detectors, which consist of water Cherenkov tanks, are sensitive to muon content they are not able to measure the number of muons directly. In this work we study using simulations the information that can be gained by adding muon detectors to the Auger surface detectors. We consider muon counters with two alternative areas

  11. Blind Reduced-Rank MMSE Detector for DS-CDMA Systems

    Directory of Open Access Journals (Sweden)

    Xiaodong Cai

    2003-01-01

    Full Text Available We first develop a reduced-rank minimum mean squared error (MMSE detector for direct-sequence (DS code division multiple access (CDMA by forcing the linear MMSE detector to lie in a signal subspace of a reduced dimension. While a reduced-rank MMSE detector has lower complexity, it cannot outperform the full-rank MMSE detector. We then concentrate on the blind reduced-rank MMSE detector which is obtained from an estimated covariance matrix. Our analysis and simulation results show that when the desired user′s signal is in a low-dimensional subspace, there exists an optimal subspace so that the blind reduced-rank MMSE detector lying in this subspace has the best performance. By properly choosing a subsspace, we guarantee that the optimal blind reduced-rank MMSE detector is obtained. An adaptive blind reduced-rank MMSE detector, based on a subspace tracking algorithm, is developed. The adaptive blind reduced-rank MMSE detector exhibits superior steady-state performance and fast convergence speed.

  12. Prototype of the stacked CdZnTe semiconductor detector for 16N measurement

    International Nuclear Information System (INIS)

    Nishizawa, Hiroshi; Inujima, Hiroshi; Fujiwara, Hirotsugu; Nakamura, Hiroaki

    2001-01-01

    Prototype of the Stacked CdZnTe Semiconductor Detector for Measurement The prototype model of the stacked CdZnTe semiconductor detector, which is able to measure the 6.13 MeV γ-ray from 16 N, was fabricated. The prototype's response calculation was carried out by Monte-Carlo method. The result of the response calculation agreed with the experiment data of check sources of 137 Cs and 60 Co, and 16 N which was measured at vicinity of the primary cooling water pipe of the nuclear reactor. The source spectra were unfolded with detector's response function obtained by simulation, and it is indicated that the incident γ-ray energy and its intensity ratio was identified and that the energy of 6 MeV γ-ray could be measured by the prototype of the stacked detector. (author)

  13. The Incident in Trench A - Follow-up and Lessons

    CERN Multimedia

    Olga Beltramello; Peter Jenni

    An incident happened on 12th October during the dismounting of the HF truck platform in Trench A in the ATLAS cavern. Nobody was injured or in direct danger to be hurt, thanks in particular to the vigilance of the lifting operation crew. However, there is ample matter to reflect upon, and to recall safety measures applicable at any time in the cavern. What happened? During the lifting operation of a lateral platform from the orange HF Truck, used for example for the calorimeter assembly, one of the ~7 m long pillars fell on the access stairs into the ATLAS detector (sector 13). The standard operation to dismount the platform consisted in first unbolting the platform from its support pillars and removing it. Then, after securing a given pillar with the crane, this pillar is unbolted from the floor and removed. By mistake, this pillar was not bolted onto the floor, and fell when the platform was removed. Nobody was present in the trench during the lifting operation and the fall of the pillar. The contractor in...

  14. Measurement of collision integral cross-sections of double-photon Compton effect using a single gamma ray detector: A response matrix approach

    International Nuclear Information System (INIS)

    Saddi, M.B.; Singh, Bhajan; Sandhu, B.S.

    2008-01-01

    The collision integral cross-sections of double-photon Compton process are measured experimentally for 662 keV incident gamma photons. The measurements are successfully carried out using a single gamma ray detector, and do not require the complicated slow-fast coincidence technique used till now for observing this higher order quantum electrodynamics (QED) process. The energy spectra of one of the two final photons, originating in this process, in direction of the gamma ray detector are observed as a long tail to the single-photon Compton line on lower side of the full energy peak in the observed spectra. An inverse response matrix converts the observed pulse-height distribution of a NaI(Tl) scintillation detector to a true photon spectrum. This also results in extraction of events originating from double-photon Compton interactions. The present measured values of collision integral cross-section, although of same magnitude, deviate from the corresponding values obtained from the theory. In view of the magnitude of deviations, in addition to small value of probability of occurrence of this process, the agreement of measured values with theory is reasonably acceptable

  15. Comparison of modeled and measured performance of a GSO crystal as gamma detector

    Energy Technology Data Exchange (ETDEWEB)

    Parno, D.S., E-mail: dparno@uw.edu [Carnegie Mellon University, Department of Physics, Pittsburgh, PA 15213 (United States); University of Washington, Center for Experimental Nuclear Physics and Astrophysics and Department of Physics, Seattle, WA 98195 (United States); Friend, M. [Carnegie Mellon University, Department of Physics, Pittsburgh, PA 15213 (United States); High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan); Mamyan, V.; Benmokhtar, F. [Carnegie Mellon University, Department of Physics, Pittsburgh, PA 15213 (United States); Camsonne, A. [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States); Franklin, G.B. [Carnegie Mellon University, Department of Physics, Pittsburgh, PA 15213 (United States); Paschke, K. [University of Virginia, Department of Physics, Charlottesville, VA 22904 (United States); Quinn, B. [Carnegie Mellon University, Department of Physics, Pittsburgh, PA 15213 (United States)

    2013-11-11

    We have modeled, tested, and installed a large, cerium-activated Gd{sub 2}SiO{sub 5} crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.

  16. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  17. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  18. An X-ray scanner prototype based on a novel hybrid gaseous detector

    CERN Document Server

    Iacobaeus, C; Lund-Jensen, B; Peskov, Vladimir

    2007-01-01

    We have developed a prototype of a new type of hybrid X-ray detector. It contains a thin wall (few μm) edge- illuminated lead glass capillary plate (acting as a converter of X-rays photons to primary electrons) combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0° to 90°. The detection efficiency, depending on the geometry, photon's energy, incident angle and the mode of operation, was between a few and 40%. The position resolution achieved was 50 μm in digital form and was practically independent of the photon's energy or gas mixture. The developed detector may open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), crystallography and many other applications.

  19. A new liquid xenon scintillation detector for positron emission tomography

    International Nuclear Information System (INIS)

    Chepel, V.Yu.

    1993-01-01

    A new positron-sensitive detector of annihilation photons filled with liquid xenon is proposed for positron emission tomography. Simultaneous detection of both liquid xenon scintillation and ionization current produces a time resolution of < 1 ns and a position resolution in the tangential direction of the tomograph ring is ∼ 1 mm and in the radial direction is ∼ 5 mm. The advantages of a tomograph with new detectors are discussed. New algorithms of Compton scattering can be used. (author)

  20. Gas pixel detector for X-ray observation

    CERN Document Server

    Attié, D; Chefdeville, M; Colas, P; Delagnes, E; Giomataris, Y; van der Graaf, H; Llopart, X; Timmermans, J; Visschers, J

    2009-01-01

    We report on the status of the R&D for a digital Time Projection Chamber (TPC) based on Micromegas (MICRO MEsh GAseous Structure) detectors using the CMOS chip TimePix as a direct readout anode protected by highly resistive a-Si:H layer. A small chamber was built as a demonstrator of the 2-D and 3-D imaging capabilities of this technique. We illustrate the new capabilities of this detector for X-ray observation with data taken from radioactive sources. This small TPC is a very useful tool both for studying gas properties thanks to its good efficiency for single electrons, and for reconstructing photoelectron direction for use as a soft X-ray polarimeter.

  1. Radiation detectors

    International Nuclear Information System (INIS)

    2013-01-01

    This sixth chapter presents the operational principles of the radiation detectors; detection using photographic emulsions; thermoluminescent detectors; gas detectors; scintillation detectors; liquid scintillation detectors; detectors using semiconductor materials; calibration of detectors; Bragg-Gray theory; measurement chain and uncertainties associated to measurements

  2. The ALEPH detector

    CERN Multimedia

    1988-01-01

    For detecting the direction and momenta of charged particles with extreme accuracy, the ALEPH detector had at its core a time projection chamber, for years the world's largest. In the foreground from the left, Jacques Lefrancois, Jack Steinberger, Lorenzo Foa and Pierre Lazeyras. ALEPH was an experiment on the LEP accelerator, which studied high-energy collisions between electrons and positrons from 1989 to 2000.

  3. Study of method of efficiency transference using detectors NaI(Ti)

    International Nuclear Information System (INIS)

    Ramos, Thiago L.; Salgado, César M.

    2017-01-01

    The use of NaI (Tl) scintillation detectors for measurements implies the determination of the detection efficiency as a function of the energy of the incident photons. The efficiency curve can be obtained experimentally with the use of several mono-energy sources calibrated with emission energies covering the whole range of interest or using the Monte Carlo method. The Institute of Nuclear Engineering develops several methodologies using these detectors as they are robust, inexpensive and do not need cooling for their use. The assembly of an experimental arrangement is usually complex, since several factors influence the result affecting reproducibility in measurements, such as: parallelism between source and detector, alignment between source and detector, and accuracy of source-detector distance. In view of such difficulties, an automated positioning system was developed for the source-detector set controlled by a micro controller based on the ARDUINO language in order to guarantee the reproducibility in the experimental arrangements. In the initial phase of this study, a mathematical model was developed in the MCNP-X code using a NaI (Tl) detector. A theoretical validation using the Efficiency Transfer Method was performed at three different positions on the detector's axial axis (10.6 cm, 11.3 cm and 12.0 cm). This method is based on the ratio of effective solid angles. The experimental validation presented maximum relative errors of 7.74% for the position 11.3 cm

  4. Domestic smoke detectors - a radioactive waste problem

    International Nuclear Information System (INIS)

    Carter, M.W.

    1996-01-01

    A common form of domestic smoke detector is the ionization chamber smoke detector. A small radioactive source provides the ionization and when smoke enters the sensitive volume the change in voltage is sensed electronically. The use of domestic ionization chamber smoke detectors is widespread and is recommended by fire authorities and insurance companies. That one million such detectors were imported into New South Wales in 1994 is an indication of the numbers involved. The typical radioactive source in a domestic smoke detector is Am 241, which is regarded as one of the more hazardous radionuclides. If it is such a hazardous material, should it be allowed in the normal household without any control? Or, in a smoke detector, is it in a less hazardous form than assumed in the ICRP recommendations and do its benefits outweigh its possible risks? In spite of the apparent hazard of Am 241, the possession of the radioactive source in smoke detectors is generally exempt from any form of regulation. Waste regulations, however, set requirements for the disposal of Am 241 and these regulations can be interpreted as applying to smoke detectors. We appear to have a situation where a home owner can legally purchase any number of smoke detectors but when they fail there are codes of practice that prevent them being disposed of. On the other hand, smoke detectors have a direct life saving function and reports indicate that smoke detectors can reduce both injury and property damage by up to 50%. Do these benefits from the use of smoke detectors compensate for any radiological risk? (author)

  5. Low-noise detector and amplifier design for 100 ns direct detection CO{sub 2} LIDAR receiver

    Energy Technology Data Exchange (ETDEWEB)

    Cafferty, M.M.; Cooke, B.J.; Laubscher, B.E.; Olivas, N.L.; Fuller, K.

    1997-06-01

    The development and test results of a prototype detector/amplifier design for a background limited, pulsed 100 ns, 10--100 kHz repetition rate LIDAR/DIAL receiver system are presented. Design objectives include near-matched filter detection of received pulse amplitude and round trip time-of-flight, and the elimination of excess correlated detector/amplifier noise for optimal pulse averaging. A novel pole-zero cancellation amplifier, coupled with a state-of-the-art SBRC (Santa Barbara Research Center) infrared detector was implemented to meet design objectives. The pole-zero cancellation amplifier utilizes a tunable, pseudo-matched filter technique to match the width of the laser pulse to the shaping time of the filter for optimal SNR performance. Low frequency correlated noise, (l/f and drift noise) is rejected through a second order high gain feedback loop. The amplifier also employs an active detector bias stage minimizing detector drift. Experimental results will be provided that demonstrate near-background limited, 100 ns pulse detection performance given a 8.5--11.5 {micro}m (300 K B.B.) radiant background, with the total noise floor spectrally white for optimal pulse averaging efficiency.

  6. Method of measuring directed electron velocities in flowing plasma using the incoherent regions of laser scattering

    International Nuclear Information System (INIS)

    Jacoby, B.A.; York, T.M.

    1979-02-01

    With the presumption that a shifted Maxwellian velocity distribution adequately describes the electrons in a flowing plasma, the details of a method to measure their directed velocity are described. The system consists of a ruby laser source and two detectors set 180 0 from each other and both set at 90 0 with respect to the incident laser beam. The lowest velocity that can be determined by this method depends on the electron thermal velocity. The application of this diagnostic to the measurement of flow velocities in plasma being lost from the ends of theta-pinch devices is described

  7. Spectral and spatial resolution properties of photon counting X-ray detectors like the Medipix-Detector

    International Nuclear Information System (INIS)

    Korn, A.

    2007-01-01

    The Medipix detector is a hybrid photon counting X-ray detector, consisting of an ASIC and a semiconducting layer as the sensor. This makes the Medipix a direct converting detector. A special feature of the Medipix is a signal processing circuit in every single pixel. This circuit amplifies the input signal triggered by a photon and then transforms the pulse into a digital signal. This early stage digitalisation is one of the main advantages of the detector, since no dark currents are integrated into the signal. Furthermore, the energy information of each single photon is partly preserved. The high number of pixels lends the detector a wide dynamic range, starting from single counts up to a rate of 1010 photons per cm2 and second. Apart from the many advantages, there are still some problems with the detector. Some effects lead to a deterioration of the energy resolution as well as the spatial resolution. The main reasons for this are two effects occuring in the detector, charge sharing and backscattering inside the detector. This study investigates the influence of those two effects on both the energy and spatial resolution. The physical causes of these effects are delineated and their impact on the detector output is examined. In contrast to high energy photon detectors, the repulsion of the charge carriers drifting inside the sensor must not be neglected in a detailed model of X-ray detectors with an energy range of 5 keV-200 keV. For the simulation of the Medipix using Monte Carlo simulations, the software ROSI was augmented. The added features allow a detailed simulation of the charge distribution, using the relevant physical effects that alter the distribution width during the drift towards the sensor electrodes as well further influences on the detector output, including electronical noise, threshold noise or the geometry of the detector. The measured energy and spatial resolution of several different models of Medipix is compared to the simulated

  8. Localization of gravitational wave sources with networks of advanced detectors

    International Nuclear Information System (INIS)

    Klimenko, S.; Mitselmakher, G.; Pankow, C.; Vedovato, G.; Drago, M.; Prodi, G.; Mazzolo, G.; Salemi, F.; Re, V.; Yakushin, I.

    2011-01-01

    Coincident observations with gravitational wave (GW) detectors and other astronomical instruments are among the main objectives of the experiments with the network of LIGO, Virgo, and GEO detectors. They will become a necessary part of the future GW astronomy as the next generation of advanced detectors comes online. The success of such joint observations directly depends on the source localization capabilities of the GW detectors. In this paper we present studies of the sky localization of transient GW sources with the future advanced detector networks and describe their fundamental properties. By reconstructing sky coordinates of ad hoc signals injected into simulated detector noise, we study the accuracy of the source localization and its dependence on the strength of injected signals, waveforms, and network configurations.

  9. Development of a new approach to simulate a particle track under electrochemical etching in polymeric detectors

    International Nuclear Information System (INIS)

    Mostofizadeh, Ali; Huang, Yudong; Kardan, M. Reza; Babakhani, Asad; Sun Xiudong

    2012-01-01

    A numerical approach based on image processing was developed to simulate a particle track in a typical polymeric detector, e.g., polycarbonate, under electrochemical etching. The physical parameters such as applied voltage, detector thickness, track length, the radii of curvature at the tip of track, and the incidence angle of the particle were considered, and then the boundary condition of the problem was defined. A numerical method was developed to solve Laplace equation, and then the distribution of the applied voltage was obtained through the polymer volume. Subsequently, the electric field strengths in the detector elements were computed. In each step of the computation, an image processing technique was applied to convert the computed values to grayscale images. The results showed that a numerical solution to Laplace equation is dedicatedly an attractive approach to provide us the accurate values of electric field strength through the polymeric detector volume as well as the track area. According to the results, for a particular condition of the detector thickness equal to 445 μm, track length of 21 μm, the radii of 2.5 μm at track tip, the incidence angle of 90°, and the applied voltage of 2080 V, after computing Laplace equation for an extremely high population of 4000 × 4000 elements of detector, the average field strength at the tip of track was computed equal to 0.31 MV cm −1 which is in the range of dielectric strength for polymers. The results by our computation confirm Smythe’s model for estimating the ECE-tracks.

  10. Study of method of efficiency transference using detectors NaI(Ti); Estudo de método de transferência de eficiência usando detectores NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Thiago L.; Salgado, César M., E-mail: thiago_lins-ramos@hotmail.com, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The use of NaI (Tl) scintillation detectors for measurements implies the determination of the detection efficiency as a function of the energy of the incident photons. The efficiency curve can be obtained experimentally with the use of several mono-energy sources calibrated with emission energies covering the whole range of interest or using the Monte Carlo method. The Institute of Nuclear Engineering develops several methodologies using these detectors as they are robust, inexpensive and do not need cooling for their use. The assembly of an experimental arrangement is usually complex, since several factors influence the result affecting reproducibility in measurements, such as: parallelism between source and detector, alignment between source and detector, and accuracy of source-detector distance. In view of such difficulties, an automated positioning system was developed for the source-detector set controlled by a micro controller based on the ARDUINO language in order to guarantee the reproducibility in the experimental arrangements. In the initial phase of this study, a mathematical model was developed in the MCNP-X code using a NaI (Tl) detector. A theoretical validation using the Efficiency Transfer Method was performed at three different positions on the detector's axial axis (10.6 cm, 11.3 cm and 12.0 cm). This method is based on the ratio of effective solid angles. The experimental validation presented maximum relative errors of 7.74% for the position 11.3 cm.

  11. The optimum lead thickness for lead-activation detectors

    International Nuclear Information System (INIS)

    Si Fenni; Hu Qingyuan

    2009-01-01

    The optimum lead thickness for lead-activation detectors has been studied in this paper. First existence of the optimum lead thickness is explained theoretically. Then the optimum lead thickness is obtained by two methods, MCNP5 calculation and mathematical estimation. At last factors which affect the optimum lead thickness are discussed. It turns out that the optimum lead thickness is irrelevant to incident neutron energies. It is recommended 2.5 cm generally.

  12. Luminosity Measurements with the ATLAS Detector

    CERN Document Server

    Maettig, Stefan; Pauly, T

    For almost all measurements performed at the Large Hadron Collider (LHC) one crucial ingredient is the precise knowledge about the integrated luminosity. The determination and precision on the integrated luminosity has direct implications on any cross-section measurement, and its instantaneous measurement gives important feedback on the conditions at the experimental insertions and on the accelerator performance. ATLAS is one of the main experiments at the LHC. In order to provide an accurate and reliable luminosity determination, ATLAS uses a variety of different sub-detectors and algorithms that measure the luminosity simultaneously. One of these sub-detectors are the Beam Condition Monitors (BCM) that were designed to protect the ATLAS detector from potentially dangerous beam losses. Due to its fast readout and very clean signals this diamond detector is providing in addition since May 2011 the official ATLAS luminosity. This thesis describes the calibration and performance of the BCM as a luminosity detec...

  13. Use of in-core self-powered detectors in the nuclear reactor control system

    International Nuclear Information System (INIS)

    Mitel'man, M.G.; Andreev, L.G.; Batenin, I.V.

    1975-01-01

    The paper describes the results of experiments conducted at the Obninsk atomic power station on the establishment of an integrated system for the control and automatic regulation of the distribution of energy liberation. The pick-ups used for this system are direct-charge detectors with rhodium emitters. The system, which consists of 12 integral DPZ-7 detectors distributed evenly on 2 mutually perpendicular diamaters and 2 assemblies, each containing 4 1n direct-charge detectors, monitors the distribution of neutron flow density according to core height. Increased signals from the detectors were fed into the summation block, in which the outgoing signal was also adjusted. The half-life of the rhodium was calculated and the non-inertia of the entire system ascertained. The total operating time of the system for the automatic control of reactor power is approximately 1 h. The influence of interference was not determined. During the experiment, the power of the reactor remained constant, i.e. its regulation by the direct-charge detectors inside the core was effective. (author)

  14. Heterodyne detection at 300 GHz using neon indicator lamp glow discharge detector.

    Science.gov (United States)

    Aharon Akram, Avihai; Rozban, Daniel; Kopeika, Natan S; Abramovich, Amir

    2013-06-10

    A miniature neon indicator lamp, also known as a glow discharge detector (GDD), costing about 50 cents, was found to be an excellent room temperature terahertz radiation detector. Proof-of-concept 300 GHz heterodyne detection using GDD is demonstrated in this paper. Furthermore, a comparison to direct detection was carried out as well. Previous results with the GDD at 10 GHz showed 40 times better sensitivity using heterodyne detection compared to direct detection. Preliminary results at 300 GHz showed better sensitivity by a factor of 20 with only 56 μW local-oscillator power using heterodyne compared to direct detection. The higher the local-oscillator power (P(lo)), the better the sensitivity of the detector. Further improvement can be achieved by employing better quasi-optical design.

  15. Using the Medipix3 detector for direct electron imaging in the range 60 keV to 200 keV in electron microscopy

    Science.gov (United States)

    Mir, J. A.; Plackett, R.; Shipsey, I.; dos Santos, J. M. F.

    2017-11-01

    Hybrid pixel sensor technology such as the Medipix3 represents a unique tool for electron imaging. We have investigated its performance as a direct imaging detector using a Transmission Electron Microscope (TEM) which incorporated a Medipix3 detector with a 300 μm thick silicon layer compromising of 256×256 pixels at 55 μm pixel pitch. We present results taken with the Medipix3 in Single Pixel Mode (SPM) with electron beam energies in the range, 60-200 keV . Measurements of the Modulation Transfer Function (MTF) and the Detective Quantum Efficiency (DQE) were investigated. At a given beam energy, the MTF data was acquired by deploying the established knife edge technique. Similarly, the experimental data required to determine DQE was obtained by acquiring a stack of images of a focused beam and of free space (flatfield) to determine the Noise Power Spectrum (NPS).

  16. CdTe Timepix detectors for single-photon spectroscopy and linear polarimetry of high-flux hard x-ray radiation.

    Science.gov (United States)

    Hahn, C; Weber, G; Märtin, R; Höfer, S; Kämpfer, T; Stöhlker, Th

    2016-04-01

    Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays - such as laser-generated plasmas - is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

  17. A performance comparison of direct- and indirect-detection flat-panel imagers

    CERN Document Server

    Partridge, M; Müller, L

    2002-01-01

    A comparison of the performance of a direct- and an indirect-detection amorphous silicon flat-panel X-ray imager is presented for a 6 MV beam. Experimental measurements of the noise characteristics, image lag, spectral response, spatial resolution and quantum efficiency are described, compared and discussed. The two systems are comprised of 512x512 pixel, 400 mu m pitch, arrays of a-Si:H p-i-n photodiodes and thin-film transistors. In the direct-detection system, X-rays interact to produce electron/hole pairs directly in the silicon photodiodes. For the indirect-detection system, a phosphor screen converts energy from the incident X-rays into visible light, which is then detected by the photodiodes. Both systems are shown to be quantum noise limited, with the total electronic noise in the detector 10-15 times smaller than the Poisson noise level in detected signal. The measured lag for both systems is 1.0+-0.1% or less in the first frame with subsequent signals decaying exponentially with frame read-out, with...

  18. Antiproton tagging and vertex fitting in a Timepix3 detector

    CERN Document Server

    Aghion, S.; The AEGIS collaboration; Antonello, M.; Belov, A.; Bonomi, G.; Brusah, R. S.; Caccia, M.; Camper, A.; Caravita, R.; Castelli, F.; Cerchiari, G.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Evans, C.; Fanì, M.; Ferragut, R.; Fesel, J.; Fontana, A.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Guatieri, F.; Hackstock, P.; Haider, S.; Hinterberger, A.; Holmestad, H.; Kellerbauer, A.; Khalidova, O.; Krasnický, D.; Lagomarsino, V.; Lansonneur, P.; Lebrun, P.; Malbrunot, C.; Mariazzi, S.; Marton, J.; Matveev, V.; Müller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Prelz, F.; Prevedelli, M.; Rienaecker, B.; Robert, J.; Røhne, O. M.; Rotondi, A.; Sandaker, H.; Santoro, R.; Smestad, L.; Sorrentino, F.; Testera, G.; Tietje, I. C.; Widmann, E.; Yzombard, P.; Zimmer, C.; Zmeskal, J.; Zurlo, N.

    2018-01-01

    Studies of antimatter are important for understanding our universe at a fundamental level. There are still unsolved problems, such as the matter-antimatter asymmetry in the universe. The AEgIS experiment at CERN aims at measuring the gravitational fall of antihydrogen in order to determine the gravitational force on antimatter. The proposed method will make use of a position-sensitive detector to measure the annihilation point of antihydrogen. Such a detector must be able to tag the antiproton, measure its time of arrival and reconstruct its annihilation point with high precision in the vertical direction. This work explores a new method for tagging antiprotons and reconstructing their annihilation point. Antiprotons from the Antiproton Decelerator at CERN was used to obtain data on direct annihilations on the surface of a silicon pixel sensor with Timepix3 readout. These data were used to develop and verify a detector response model for annihilation of antiprotons in this detector. Using this model and the a...

  19. Signs of cosmic rays in gravitational wave detectors

    International Nuclear Information System (INIS)

    Tavares, Denis Borgarelli

    2010-01-01

    One of the phenomena predicted by Einstein in the derivation of general relativity is the existence of small perturbations of the metric that he named gravitational waves. As they travel through space oscillates the space-time according to its polarization. This is the only major prediction of general relativity not yet proven completely. The small signal generated by the passage of a gravitational wave compared to the noise in the system of detection makes their direct detection one challenge of modern science. In this paper we study the noise generated by cosmic rays in the gravitational antenna Mario Schenberg, located in the city of Sao Paulo. Single muons and hadrons flux measurements held in the northern hemisphere were used to calculate the expected flux of these particles in the city of Sao Paulo. The calculation of the energy deposited in the detector of gravitational waves from cosmic rays was performed by Monte Carlo simulations using Geant4. The transport of muons and protons, with several energy and some different angles of incidence, across the building and the resonant sphere was simulated. We developed a thermo-acoustic model, called multi-point, suitable for calculating the energy deposited in the normal modes from the energy deposited on the sphere by elementary particles. With these results we calculate the expected rate of cosmic ray signals in the main detection mode of gravitational waves, nl = 12, of the Mario Schenberg detector, for temperatures T noise between 10 -5 and 10 -7 K. The results showed for the designed for 4.2 K sensitivity of the Mario Schenberg detector that the rate of signals due to cosmic rays is very small, being around 5 events per day. However, when it will reach the quantum limit will be needed a more detailed analysis of the antenna signal output, since the expected number of cosmic ray noise increases considerably, reaching about 250 signals per day. (author)

  20. Ionization detector

    International Nuclear Information System (INIS)

    Steele, D.S.

    1987-01-01

    An ionization detector having an array of detectors has, for example, grounding pads positioned in the spaces between some detectors (data detectors) and other detectors (reference detectors). The grounding pads are kept at zero electric potential, i.e. grounded. The grounding serves to drain away electrons and thereby prevent an unwanted accumulation of charge in the spaces, and cause the electric field lines to be more perpendicular to the detectors in regions near the grounding pads. Alternatively, no empty space is provided there being additional, grounded, detectors provided between the data and reference detectors. (author)

  1. Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Cowen, A.R. [LXi Research, Academic Unit of Medical Physics, University of Leeds, West Yorkshire (United Kingdom)], E-mail: a.r.cowen@leeds.ac.uk; Kengyelics, S.M.; Davies, A.G. [LXi Research, Academic Unit of Medical Physics, University of Leeds, West Yorkshire (United Kingdom)

    2008-05-15

    Solid-state, digital radiography (DR) detectors, designed specifically for standard projection radiography, emerged just before the turn of the millennium. This new generation of digital image detector comprises a thin layer of x-ray absorptive material combined with an electronic active matrix array fabricated in a thin film of hydrogenated amorphous silicon (a-Si:H). DR detectors can offer both efficient (low-dose) x-ray image acquisition plus on-line readout of the latent image as electronic data. To date, solid-state, flat-panel, DR detectors have come in two principal designs, the indirect-conversion (x-ray scintillator-based) and the direct-conversion (x-ray photoconductor-based) types. This review describes the underlying principles and enabling technologies exploited by these designs of detector, and evaluates their physical imaging characteristics, comparing performance both against each other and computed radiography (CR). In standard projection radiography indirect conversion DR detectors currently offer superior physical image quality and dose efficiency compared with direct conversion DR and modern point-scan CR. These conclusions have been confirmed in the findings of clinical evaluations of DR detectors. Future trends in solid-state DR detector technologies are also briefly considered. Salient innovations include WiFi-enabled, portable DR detectors, improvements in x-ray absorber layers and developments in alternative electronic media to a-Si:H.

  2. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  3. Detector and quantifier of ionizing x-radiation by indirect method

    International Nuclear Information System (INIS)

    Pablo, Aramayo; Roberto, Cruz; Luis, Rocha; Rotger Viviana I; Olivera, Juan Manuel

    2007-01-01

    The work presents the development of a device able to detect and quantify ionizing radiations. The transduction principle proposed for the design of the detector consists on using the properties of the fluorescent screens able to respond to the incident radiation with a proportional brightness. Though the method is well-known, it proved necessary to optimize the design of the detectors in order to get a greater efficiency in the relationship radiation/brightness; to that purpose, different models were tried out, varying its geometry and the optoelectronic device. The resultant signal was processed and presented in a visualization system. It is important to highlight that the project is in development and the results we obtained are preliminary

  4. 3D position estimation using an artificial neural network for a continuous scintillator PET detector

    International Nuclear Information System (INIS)

    Wang, Y; Zhu, W; Cheng, X; Li, D

    2013-01-01

    Continuous crystal based PET detectors have features of simple design, low cost, good energy resolution and high detection efficiency. Through single-end readout of scintillation light, direct three-dimensional (3D) position estimation could be another advantage that the continuous crystal detector would have. In this paper, we propose to use artificial neural networks to simultaneously estimate the plane coordinate and DOI coordinate of incident γ photons with detected scintillation light. Using our experimental setup with an ‘8 + 8’ simplified signal readout scheme, the training data of perpendicular irradiation on the front surface and one side surface are obtained, and the plane (x, y) networks and DOI networks are trained and evaluated. The test results show that the artificial neural network for DOI estimation is as effective as for plane estimation. The performance of both estimators is presented by resolution and bias. Without bias correction, the resolution of the plane estimator is on average better than 2 mm and that of the DOI estimator is about 2 mm over the whole area of the detector. With bias correction, the resolution at the edge area for plane estimation or at the end of the block away from the readout PMT for DOI estimation becomes worse, as we expect. The comprehensive performance of the 3D positioning by a neural network is accessed by the experimental test data of oblique irradiations. To show the combined effect of the 3D positioning over the whole area of the detector, the 2D flood images of oblique irradiation are presented with and without bias correction. (paper)

  5. Amorphous silicon/crystalline silicon heterojunctions for nuclear radiation detector applications

    International Nuclear Information System (INIS)

    Walton, J.T.; Hong, W.S.; Luke, P.N.; Wang, N.W.; Ziemba, F.P.

    1996-10-01

    Results on characterization of electrical properties of amorphous Si films for the 3 different growth methods (RF sputtering, PECVD [plasma enhanced], LPCVD [low pressure]) are reported. Performance of these a-Si films as heterojunctions on high resistivity p-type and n- type crystalline Si is examined by measuring the noise, leakage current, and the alpha particle response of 5mm dia detector structures. It is demonstrated that heterojunction detectors formed by RF sputtered films and PECVD films are comparable in performance with conventional surface barrier detectors. Results indicate that the a-Si/c-Si heterojunctions have the potential to greatly simplify detector fabrication. Directions for future avenues of nuclear particle detector development are indicated

  6. Amorphous silicon/crystalline silicon heterojunctions for nuclear radiation detector applications

    International Nuclear Information System (INIS)

    Walton, J.T.; Hong, W.S.; Luke, P.N.; Wang, N.W.; Ziemba, F.P.

    1996-01-01

    Results on the characterization of the electrical properties of amorphous silicon films for the three different growth methods, RF sputtering, PECVD, and LPCVD are reported. The performance of these a-Si films as heterojunctions on high resistivity p-type and n-type crystalline silicon is examined by measuring the noise, leakage current and the alpha particle response of 5 mm diameter detector structures. It is demonstrated that heterojunction detectors formed by RF sputtered films and PECVD films are comparable in performance with conventional surface barrier detectors. The results indicate that the a-Si/c-Si heterojunctions have the potential to greatly simplify detector fabrication. Directions for future avenues of nuclear particle detector development are indicated

  7. On the suitability of P Si-PIN detectors in transmission experiments

    International Nuclear Information System (INIS)

    Murty, V.R.K.; Devan, K.R.S.

    2000-01-01

    There has been considerable interest, in the recent past, in the development of detector technology. In this context, new detectors, especially room temperature operated detectors and inexpensive cooling systems have recently entered the market. These new systems replace the old systems where there are inadequate facilities to operate them to achieve superior performance. Such performance capabilities of different systems, on a comparative basis have not been widely published in the recent past. In this direction, the Peltier cooled detectors have entered the market and are replacing the conventional Si(Li) detectors. In between the conventional Si(Li) detectors and Peltier cooled Si-PIN detectors, the freolectric cooled Si(Li) detectors were also used in Radiation Physics applications. In this paper, the performance of the Peltier cooled Si-PIN detector in comparison with a Freolectric cooled Si(Li) detector has been studied in Transmission experiments to evaluate the total cross sections at low energies and the results are discussed. (author)

  8. Review of incidents to be reported under the Radiation Protection Ordinance for the years 1987 and 1988

    International Nuclear Information System (INIS)

    1989-01-01

    The total of 80 incidents were caused by human failure, intentional disruption, theft, fire, violation of rules, transport losses, accidents, equipment deficiencies. 15 ionization smoke detectors were reported lost or stolen. (HP) [de

  9. Astronomical observations with a network of detectors of gravitational waves: Pt. 1

    International Nuclear Information System (INIS)

    Dhurandhar, S.V.; Tinto, Massimo

    1988-01-01

    Two different representations for the antenna pattern of Earth-based gravitational wave detectors (laser interferometers and bars) observing arbitrarily polarized waves are investigated in the long wavelength limit. We show that the response of a gravitational wave detector can be written either as a contraction between two symmetric trace-free (STF) tensors, one associated with the wave and the other with the detector, or as a linear combination of generalized spherical functions. We then apply this formalism to solve the simplest form of the 'inverse problem' for bursts: determining the direction of an incoming wave, the orientation of its polarization ellipse and the wave's two independent amplitudes, using only the response amplitudes of five wide-band detectors located in the same place. We give a simple linear expression for the components of the STF tensor that characterize the wave as a function of the detector responses. We then show how to solve for the wave's direction, polarization and amplitude from its STF tensor. (author)

  10. Police Response to Children Present at Domestic Violence Incidents.

    Science.gov (United States)

    Swerin, Danielle D; Bostaph, Lisa Growette; King, Laura L; Gillespie, Lane Kirkland

    2018-01-01

    Police response to domestic violence (DV) has continued to change and expand over the past several decades. Although DV was originally considered a private matter, it now represents one of the most common calls for service received by police agencies. While police response to DV incidents has improved substantially, intervention when children are present remains an undeveloped area of research and practice. The present study examined 345 police reports from an agency in the Northwestern United States to explore police response to DV incidents when children are present. Regression analyses indicated that child presence was a statistically significant predictor of victim-directed intervention, victim-directed follow-up, and arrest although in differing directions. While child presence increased the odds of victim-directed intervention and victim-directed follow-up, it decreased the odds of arrest. Findings further indicated that the frequency of police interaction with children present at DV incidents was minimal. Based on these findings, recommendations for policy and practice are discussed.

  11. 4D tracking with ultra-fast silicon detectors

    Science.gov (United States)

    F-W Sadrozinski, Hartmut; Seiden, Abraham; Cartiglia, Nicolò

    2018-02-01

    The evolution of particle detectors has always pushed the technological limit in order to provide enabling technologies to researchers in all fields of science. One archetypal example is the evolution of silicon detectors, from a system with a few channels 30 years ago, to the tens of millions of independent pixels currently used to track charged particles in all major particle physics experiments. Nowadays, silicon detectors are ubiquitous not only in research laboratories but in almost every high-tech apparatus, from portable phones to hospitals. In this contribution, we present a new direction in the evolution of silicon detectors for charge particle tracking, namely the inclusion of very accurate timing information. This enhancement of the present silicon detector paradigm is enabled by the inclusion of controlled low gain in the detector response, therefore increasing the detector output signal sufficiently to make timing measurement possible. After providing a short overview of the advantage of this new technology, we present the necessary conditions that need to be met for both sensor and readout electronics in order to achieve 4D tracking. In the last section, we present the experimental results, demonstrating the validity of our research path.

  12. Directional sensitivity of MuSTAnG muon telescope

    Directory of Open Access Journals (Sweden)

    Ganeva Marina

    2013-04-01

    Full Text Available We investigate directional sensitivity of MuSTAnG muon telescope by deriving the distribution of secondary muons, which create the counting rate of telescope, by asymptotic directions of primary protons. This distribution, defined as “directivity function”, allows us to clarify protons appearing from which direction essentially contribute to counting rate of detector. Directivity function has different behavior for the muons falling on the telescope at different zenith and polar angles. Vertical, West, and East fluxes exhibit strong maximums near the asymptotic longitude about 61°, whereas North and South fluxes have larger spread distributions. About 65% of muons, which create the Vertical counting rate of MuSTAnG, are produced by the primary protons, coming in the interval of asymptotic longitudes about (50°, 80°. Using directivity function will allow one to more correctly determine the location of interplanetary disturbances. Analogous analysis, made for other muon detectors, will clarify their directional sensitivities, improving by this the forecasting capability of network of ground-based muon detectors.

  13. Accurate and independent spectral response scale based on silicon trap detectors and spectrally invariant detectors

    International Nuclear Information System (INIS)

    Gran, Jarle

    2005-01-01

    The study aims to establish an independent high accuracy spectral response scale over a broad spectral range based on standard laboratory equipment at a moderate cost. This had to be done by a primary method, where the responsivity of the detector is linked to fundamental constants. Summary, conclusion and future directions: In this thesis it has been demonstrated that an independent spectral response scale from the visual to the IR based on simple relative measurements can be established. The accuracy obtained by the hybrid self-calibration method demonstrates that state of the art accuracy is obtained with self-calibration principles. A calculable silicon trap detector with low internal losses over a wide spectral range is needed to establish the scale, in addition to a linear, spectrally independent detector with a good signal to noise ratio. By fitting the parameters in the responsivity model to a purely relative measurement we express the spectral response in terms of fundamental constants with a known uncertainty This is therefore a primary method. By applying a digital filter on the relative measurements of the InGaAs detectors in the infrared reduces the standard deviation by 30 %. In addition, by optimising the necessary scaling constant converting the relative calibration to absolute values, we have managed to establish an accurate and cost efficient spectral response scale in the IR. The full covariance analysis, which takes into account the correlation in the absolute values of the silicon detector, the correlation caused by the filter and the scaling constant, shows that the spectral response scale established in the infrared with InGaAs detectors is done with high accuracy. A similar procedure can be used in the UV, though it has not been demonstrated here. In fig. 10 the responsitivities of the detectors (a) and their associated uncertainties (b) at the 1 sigma level of confidence is compared for the three publications. We see that the responsivity

  14. The one- and two-coordinate x-ray detectors

    International Nuclear Information System (INIS)

    Aulchenko, V.M.; Baru, S.E.; Khabakhpashev, A.G.; Savinov, G.A.

    1992-01-01

    The Institute of Nuclear Physics has designed and fabricated one- and two-coordinate x-ray detectors since 1975. For photon detection multiwire proportional chambers that operate in direct pulse count mode are employed. The characteristics of the detectors allow successful use of them for a wide range of diffractive x-ray structure studies, including studies of dynamics of structure variation (x-ray diffractive movies) and measurements at synchrotron radiation channels

  15. Electronic alarm device for radioactivity detector associated with a direct current amplifier or with a integration-based counting assembly

    International Nuclear Information System (INIS)

    Desmaretz, Marc; Ferlicot, Rene

    1964-04-01

    The authors report the study of a device aimed at triggering sound and light alarms when a radiation detector associated with a direct current amplifier or with a counting assembly detects a radiation intensity greater than one or two previously defined thresholds. This device can be used at any time for a detection assembly which is not continuously monitored. It has been designed to be adapted to the CEA standard electronics currently used in installations and on which the alarm function had not been initially foreseen. The assembly comprises an additional safety device for the control of any untimely shutdown of the detection chain [fr

  16. Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations

    International Nuclear Information System (INIS)

    Smith, Mark F; Raylman, Raymond R; Majewski, Stan; Weisenberger, Andrew G

    2004-01-01

    Positron emission mammography (PEM) with tomographic acquisition using dual planar detectors rotating about the breast can obtain complete angular sampling and has the potential to improve activity estimation compared with PEM using stationary detectors. PEM tomography (PEMT) was compared with stationary PEM for point source and compressed breast phantom studies performed with a compact dual detector system. The acquisition geometries were appropriate for the target application of PEM guidance of stereotactic core biopsy. Images were reconstructed with a three-dimensional iterative maximum likelihood expectation maximization algorithm. PEMT eliminated blurring normal to the detectors seen with stationary PEM. Depth of interaction effects distorted the shape of the point spread functions for PEMT as the angular range from normal incidence of lines of response used in image reconstruction increased. Streak artefacts in PEMT for large detector rotation increments led to the development of an expression for the maximum rotation increment that maintains complete angular sampling. Studies with a compressed breast phantom were used to investigate contrast and signal-to-noise ratio (SNR) trade-offs for different sized spherical tumour models. PEMT and PEM both had advantages depending on lesion size and detector separation. The most appropriate acquisition method for specific detection or quantitation tasks requires additional investigation

  17. Ground detectors for the study of cosmic ray showers

    International Nuclear Information System (INIS)

    Salazar, H; Villasenor, L

    2008-01-01

    We describe the work that we have done over the last decade to design and construct instruments to measure properties of cosmic rays in Mexico. We describe the detection of decaying and crossing muons in a water Cherenkov detector and discuss an application of these results to calibrate water Cherenkov detectors. We also describe a technique to separate isolated isolated muons and electrons in water Cherenkov detector. Next we describe the design and performance of a hybrid extensive air shower detector array built on the Campus of the University of Puebla (19 deg. N, 90 deg. W, 800 g/cm 2 ) to measure the energy, arrival direction and composition of primary cosmic rays with energies around 1 PeV

  18. Systematic Comparison of the MINOS Near and Far Detector Readout Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, Anatael [Univ. of Oxford (United Kingdom). Queen' s College

    2005-06-22

    The MINOS experiment is a neutrino oscillation baseline experiment intending to use high resolution L/E neutrinos to measure the atmospheric neutrino oscillations parameters to unprecedented precision. Two detectors have been built to realize the measurements, a Near detector, located about 1km downstream from the beam target at the Fermi Laboratory, and a Far detector, located at 736km, at the Soudan Laboratory. The technique relies on the Near detector to measure the un-oscillated neutrino spectrum, while the Far detector measures the neutrino spectrum once oscillated. The comparison between the two measurements is expected to allow MINOS to measure Δm2 beyond 10% precision level. The Near and Far detectors have been built similarly to minimize possible systematic effects. Both detectors have been endowed with different readout systems, as the beam event rates are very different. The MINOS calibration detector (CalDet), installed at CERN, was instrumented with both readout systems such that they can simultaneously measure and characterize the energy deposition (response and event topology) of incident known particle from test-beams. This thesis presents the investigations to quantify the impact of the performance of both readout systems on the MINOS results using the measurements obtained with CalDet. The relative comparison of the responses of both readout systems have been measured to be consistent with being identical within a systematic uncertainty of 0.6%. The event topologies have been found to be negligibly affected. In addition, the performance of the detector simulations have been thoroughly investigated and validated to be in agreement with data within similar level of uncertainties.

  19. A tewlve detector coincidence spectrometer for on-line and off-line measurements of nuclear g-factors

    International Nuclear Information System (INIS)

    Alfter, I.; Bodenstedt, E.; Hamer, B.; Hoff, J. van den; Knichel, W.; Muenning, H.; Piel, S.; Schueth, J.; Sajok, R.

    1992-01-01

    A twelve detector γ-γ directional correlation setup is described which has been designed and constructed for high precision on-line and off-line IPAC measurements. A ring of twelve BaF 2 detectors which may be replaced by Ge detectors is arranged around a superconducting magnet providing a maximum magnetic field of 4.5 T. In on-line experiments the magnetic field has the direction of the beam which passes through a central bore of the magnet. The data acquisition system stores directly the Esub(γ 1 )-Esub(γ 2 ) coincidence matrices for all 66 two-detector combinations in two 8 Mbyte RAMs, one for each of the two field directions. This allows a very fast data evaluation with a small on-line computer. The apparatus got into operation one-and-a-halve years ago and revealed excellent properties. (orig.)

  20. Ultrafast photon number resolving detector with a temperature stabilized si multi pixel photon counter

    International Nuclear Information System (INIS)

    Song, Minsoo; Hong, Eugene; Won, Eunil; Yoon, Tai Hyun

    2008-01-01

    Quantum information science has been rapidly progressed and matured and matured thanks to the recent developments of the single photon detection technologies. Single photon detectors such as a Si avalanche photo diode(APD)in the infrared, an InGaAs/InP APD in the telecommunication band, and a super conducting transient edge sensor(TES)in the broad region of the spectrum have been widely used. Single photon detectors, however, operating at the ultraviolet to visible (370nm∼800nm)regions has not been actively investigated partly due to the lack of single photon and/or entangled photon sources and the lack of solid state single photon detectors. In this paper, we investigate the single photon detection characteristics of a Si multi pixel photon counter(MPPC), which has a high spectral responsivity between 300nm to 800nm, as a photon number resolving solid state detector. Figure 1 shows the schematic diagram of the single photon detection set up at 399nm by using a temperature stabilized Si MPPC. The output beam of the laser being properly attenuated is directed to the MPPC module, at which fixed number of photo electrons corresponding to incident individual photon are generated at Geiger mode of the Si APD pixels. The detected photo current is converted into a digital signal by using a fast analog to digital converter and a digital oscilloscope stores the time sequence of the photo currents. Figure 2 shows the accumulated charges collected by MPPC at∼10.deg.C showing a clear single photon and two photons peaks, respectively, separated by ∼5 sigma of the coincidence counts at the two output ports of a Mach Zender interferometer as a function of optical path length difference. The research was supported by Seoul R and BD program(NT070127)and by the KRISS

  1. Ultrafast photon number resolving detector with a temperature stabilized si multi pixel photon counter

    Energy Technology Data Exchange (ETDEWEB)

    Song, Minsoo; Hong, Eugene; Won, Eunil; Yoon, Tai Hyun [Korea Univ., Seoul (Korea, Republic of)

    2008-11-15

    Quantum information science has been rapidly progressed and matured and matured thanks to the recent developments of the single photon detection technologies. Single photon detectors such as a Si avalanche photo diode(APD)in the infrared, an InGaAs/InP APD in the telecommunication band, and a super conducting transient edge sensor(TES)in the broad region of the spectrum have been widely used. Single photon detectors, however, operating at the ultraviolet to visible (370nm∼800nm)regions has not been actively investigated partly due to the lack of single photon and/or entangled photon sources and the lack of solid state single photon detectors. In this paper, we investigate the single photon detection characteristics of a Si multi pixel photon counter(MPPC), which has a high spectral responsivity between 300nm to 800nm, as a photon number resolving solid state detector. Figure 1 shows the schematic diagram of the single photon detection set up at 399nm by using a temperature stabilized Si MPPC. The output beam of the laser being properly attenuated is directed to the MPPC module, at which fixed number of photo electrons corresponding to incident individual photon are generated at Geiger mode of the Si APD pixels. The detected photo current is converted into a digital signal by using a fast analog to digital converter and a digital oscilloscope stores the time sequence of the photo currents. Figure 2 shows the accumulated charges collected by MPPC at∼10.deg.C showing a clear single photon and two photons peaks, respectively, separated by ∼5 sigma of the coincidence counts at the two output ports of a Mach Zender interferometer as a function of optical path length difference. The research was supported by Seoul R and BD program(NT070127)and by the KRISS.

  2. Direct and indirect detection of supersymmetric dark matter; Detection directe et indirecte de matiere sombre supersymetrique

    Energy Technology Data Exchange (ETDEWEB)

    Mayet, F

    2001-09-01

    A substantial body of astrophysical evidence supports the existence of non-baryonic dark matter in the universe. One of the leading dark matter candidates is the neutralino predicted by the supersymmetric extensions of the standard model of particle physics. Different detectors have been designed for the detection, either indirect or direct, of the neutralino. Related to indirect detection, the present work has been performed in the context of the AMS experiment. A precursor version of the spectrometer was flown on the space shuttle Discovery in June 1998. The detector included an Aerogel Threshold Cherenkov counter (ATC) to identify antiprotons, whose spectrum may be used to infer a neutralino signal. The analysis of the ATC data is presented including an evaluation of the flight performance and a description of the optimization of the antiproton selection. An antiproton analysis is also reported. A phenomenological study allows us to investigate the discovery potential of this indirect method. This thesis also includes the development of a new detector (MACHe3) designed for direct neutralino search using a superfluid {sup 3}He bolometer operated at ultra low temperatures. The data analysis of the prototype cell is presented. A Monte Carlo simulation has been developed, in order to optimize the detector design for direct neutralino search. These results are compared with theoretical predictions of supersymmetric models, thus highlighting the discovery potential of this detector and its complementarity with existing devices. (author)

  3. The Data Acquisition System for a Kinetic Inductance Detector

    International Nuclear Information System (INIS)

    Branchini, P; Budano, A; Capasso, L; Marchetti, D

    2015-01-01

    The Data Acquisition System (DAQ) and the Front-End electronics for an array of Kinetic Inductance Detectors (KIDs) are described. KIDs are superconductive detectors, in which electrons are organized in Cooper pairs. Any incident radiation could break a pair generating a couple of quasi-particles that increase the inductance of the detector. The DAQ system we developed is a hardware/software co-design, based on state machines and on a microprocessor embedded into an FPGA. A commercial DAC/ADC board is used to interface the FPGA to the array of KIDs. The DAQ system generates a Stimulus signal suitable for an array of up to 128 KIDs. Such signal is up-mixed with a 3 GHz carrier wave and it then excites the KIDs array. The read-out signal from the detector is down-mixed with respect to the 3 GHz sine wave and recovered Stimulus is read back by the ADC device. The microprocessor stores read out data via a PCI express bus (PCIe) into an external disk. It also computes the Fast Fourier Transform of the acquired read out signal: this allows extrapolating which KID interacted and the energy of the impinging radiation. Simulations and tests have been performed successfully and experimental results are presented. (paper)

  4. ORION, a multipurpose detector for neutrons. Some new developments

    International Nuclear Information System (INIS)

    Perier, Y.; Lienard, E.; Lott, B.; Galin, J.; Morjean, M.; Peghaire, A.; Quednau, B.; El Masri, Y.; Keutgen, Th.; Tilquin, I.

    1996-01-01

    Different properties of the four-pi neutron detector ORION have been tested: its efficiency in both modes, fast and delayed, its time resolution and position sensitivity. For the later test, the impact of the neutron beam onto the detector was varied by sliding it, perpendicular to the beam direction. All the presented data are tentative with the analysis still in progress. (K.A.)

  5. Characterization of spectrometric photon-counting X-ray detectors at different pitches

    Science.gov (United States)

    Jurdit, M.; Brambilla, A.; Moulin, V.; Ouvrier-Buffet, P.; Radisson, P.; Verger, L.

    2017-09-01

    There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm2. Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 106 incident photons.s-1.mm-2.

  6. Online calibrations and performance of the ATLAS Pixel Detector

    CERN Document Server

    Keil, M; The ATLAS collaboration

    2010-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN. It consists of 1744 silicon sensors equipped with approximately 80 M electronic channels, providing typically three measurement points with high resolution for particles emerging from the beam-interaction region, thus allowing measuring particle tracks and secondary vertices with very high precision. The readout system of the Pixel Detector is based on a bi-directional optical data transmission system between the detector and the data acquisition system with an individual link for each of the 1744 modules. Signal conversion components are located on both ends, approximately 80 m apart. The talk will give an overview of the calibration and performance of both the detector and its optical readout. The most basic parameter to be tuned and calibrated for the detector electronics is the readout threshold of the individual pixel channels. These need to be carefully tuned to optimise position resolution a...

  7. Self powered neutron detectors as in-core detectors for Sodium-cooled Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Verma, V., E-mail: vasudha.verma@physics.uu.se [Division of Applied Nuclear Physics, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-lez-Durance (France); Barbot, L.; Filliatre, P. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-lez-Durance (France); Hellesen, C. [Division of Applied Nuclear Physics, Uppsala University, Box 516, SE-75120 Uppsala (Sweden); Jammes, C. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-lez-Durance (France); Svärd, S. Jacobsson [Division of Applied Nuclear Physics, Uppsala University, Box 516, SE-75120 Uppsala (Sweden)

    2017-07-11

    Neutron flux monitoring system forms an integral part of the design of a Generation IV sodium cooled fast reactor. Diverse possibilities of detector system installation must be studied for various locations in the reactor vessel in order to detect any perturbations in the core. Results from a previous paper indicated that it is possible to detect changes in neutron source distribution initiated by an inadvertent withdrawal of outer control rod with in-vessel fission chambers located azimuthally around the core. It is, however, not possible to follow inner control rod withdrawal and precisely know the location of the perturbation in the core. Hence the use of complimentary in-core detectors coupled with the peripheral fission chambers is proposed to enable robust core monitoring across the radial direction. In this paper, we assess the feasibility of using self-powered neutron detectors (SPNDs) as in-core detectors in fast reactors for detecting local changes in the power distribution when the reactor is operated at nominal power. We study the neutron and gamma contributions to the total output current of the detector modelled with Platinum as the emitter material. It is shown that this SPND placed in an SFR-like environment would give a sufficiently measurable prompt neutron induced current of the order of 600 nA/m. The corresponding induced current in the connecting cable is two orders of magnitude lower and can be neglected. This means that the SPND can follow in-core power fluctuations. This validates the operability of an SPND in an SFR-like environment. - Highlights: • Studied possibility of using SPNDs as in-core detectors in SFRs. • Study done to detect local power profile changes when reactor is at nominal power. • SPND with a Pt-emitter gives measurable prompt current of the order of 600 nA/m. • Dominant proportion of prompt response is maintained throughout the operation. • Detector signal gives dynamic information on the power fluctuations.

  8. Self powered neutron detectors as in-core detectors for Sodium-cooled Fast Reactors

    Science.gov (United States)

    Verma, V.; Barbot, L.; Filliatre, P.; Hellesen, C.; Jammes, C.; Svärd, S. Jacobsson

    2017-07-01

    Neutron flux monitoring system forms an integral part of the design of a Generation IV sodium cooled fast reactor. Diverse possibilities of detector system installation must be studied for various locations in the reactor vessel in order to detect any perturbations in the core. Results from a previous paper indicated that it is possible to detect changes in neutron source distribution initiated by an inadvertent withdrawal of outer control rod with in-vessel fission chambers located azimuthally around the core. It is, however, not possible to follow inner control rod withdrawal and precisely know the location of the perturbation in the core. Hence the use of complimentary in-core detectors coupled with the peripheral fission chambers is proposed to enable robust core monitoring across the radial direction. In this paper, we assess the feasibility of using self-powered neutron detectors (SPNDs) as in-core detectors in fast reactors for detecting local changes in the power distribution when the reactor is operated at nominal power. We study the neutron and gamma contributions to the total output current of the detector modelled with Platinum as the emitter material. It is shown that this SPND placed in an SFR-like environment would give a sufficiently measurable prompt neutron induced current of the order of 600 nA/m. The corresponding induced current in the connecting cable is two orders of magnitude lower and can be neglected. This means that the SPND can follow in-core power fluctuations. This validates the operability of an SPND in an SFR-like environment.

  9. Selection of the optimum condition for electron capture detector operation

    International Nuclear Information System (INIS)

    Lasa, J.; Korus, A.

    1974-01-01

    A method of determination of the optimal work conditions for the electron capture detector is presented in the paper. Physical phenomena which occur in the detector, as well as the energetic dependence of the electron attachment process are taken into consideration. The influence of the kind of carrier gas, temperature, and the parameters of the supplied voltage in both direct and pulse methods on average values of electron energy is described. Dependence of the sensitivity of the electron capture detector on the carrier gas and the polarizing voltage is illustrated for the Model DNW-300 electron capture detector produced in Poland. Practical indications for selecting optimal conditions of electron capture detector operation are given at the end of the paper. (author)

  10. A high-resolution multiwire area detector for X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Faruqi, A R; Andrews, H [Medical Research Council, Cambridge (UK). Lab. of Molecular Biology

    1989-11-10

    A high-resolution multiwire area detector has been developed for recording X-ray scattering from biological specimens. The detector is 100x100 mm{sup 2} and, under the present operating conditions, has a spatial resolution of about 250 {mu}m in both directions. The detector is set up on a double-mirror focusing camera on a rotating anode X-ray generator and has been used in a number of small-angle experiments, two of which are described in this paper. (orig.).

  11. Online Calibration and Performance of the ATLAS Pixel Detector

    CERN Document Server

    Keil, M

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN. It consists of 1744 silicon sensors equipped with approximately 80 million electronic channels, providing typically three measurement points with high resolution for particles emerging from the beam-interaction region, thus allowing measuring particle tracks and secondary vertices with very high precision. The readout system of the Pixel Detector is based on a bi-directional optical data transmission system between the detector and the data acquisition system with an individual link for each of the 1744 modules. Signal conversion components are located on both ends, approximately 80 m apart. This paper describes the tuning and calibration of the optical links and the detector modules, including measurements of threshold, noise, charge measurement, timing performance and the sensor leakage current.

  12. Response function of semiconductor detectors, Ge and Si(Li); Funcao resposta de detectores semicondutores, Ge e Si(Li)

    Energy Technology Data Exchange (ETDEWEB)

    Zevallos Chavez, Juan Yury

    2003-07-01

    The Response Function (RF) for Ge and Si(Li) semiconductor detectors was obtained. The RF was calculated for five detectors, four Hp Ge with active volumes of 89 cm{sup 3} , 50 cm{sup 3} , 8 cm{sup 3} and 5 cm{sup 3}, and one Si(Li) with 0.143 cm{sup 3} of active volume. The interval of energy studied ranged from 6 keV up to 1.5 MeV. Two kinds of studies were done in this work. The first one was the RF dependence with the detection geometry. Here the calculation of the RF for a geometry named as simple and an extrapolation of that RF, were both done. The extrapolation process analyzed both, spectra obtained with a shielding geometry and spectra where the source-detector distance was modified. The second one was the RF dependence with the detection electronics. This study was done varying the shaping time of the pulse in the detection electronics. The purpose was to verify the effect of the ballistic deficit in the resolution of the detector. This effect was not observed. The RF components that describe the region of the total absorption of the energy of the incident photons, and the partial absorption of this energy, were both treated. In particular, empirical functions were proposed for the treatment of both, the multiple scattering originated in the detector (crystal), and the photon scattering originated in materials of the neighborhood of the crystal. Another study involving Monte Carlo simulations was also done in order to comprehend the photon scattering structures produced in an iron shield. A deconvolution method is suggested, for spectra related to scattered radiation in order to assess the dose delivered to the scatterer. (author)

  13. POSSuMUS. A position sensitive scintillating muon SiPM detector

    International Nuclear Information System (INIS)

    Ruschke, Alexander

    2014-01-01

    The development of a modular designed large scale scintillation detector with a two-dimensional position sensitivity is presented in this thesis. This novel POsition Sensitive Scintillating MUon SiPM Detector is named POSSuMUS. The POSSuMUS detector is capable to determine the particle's position in two space dimensions with a fast trigger capability. Each module is constructed from two trapezoidal shaped plastic scintillators to form one rectangular shaped detector module. Both trapezoids are optically insulated against each other. In both trapezoids the scintillation light is collected by plastic fibers and guided towards silicon photomultipliers (SiPMs). SiPMs are light sensors which are capable to detect even smallest amounts of light. By combining several detector modules, position sensitive areas from 100 cm 2 to few m 2 are achievable with few readout channels. Therefore, POSSuMUS provides a cost effective detector concept. The position sensitivity along the trapezoidal geometry of one detector module is achieved by the path length dependent amount of detected light for crossing particles. The ratio of the light yields in both trapezoids is calculated. This value corresponds to the position of the particle traversing the detector. A spatial resolution in the order of several mm is foreseen. The position sensitivity along the scintillator module is determined by the propagation time of light to the SiPMs located on opposite sides of the detector. A spatial resolution of few cm is expected for this direction. The POSSuMUS detector is applicable as large area trigger detector with a two dimensional position information of crossing particles. This is suitable in detector tests of large area precesion detectors or for measuring the small angle scattering of cosmic muons. At the beginning of this thesis, the determination of important SiPM characteristics like the breakdown voltage is presented. In the course of this work the detector principle is proven by

  14. Prospects for hybrid pixel detectors in electron microscopy

    International Nuclear Information System (INIS)

    Faruqi, A.R.

    2001-01-01

    The current status of CCD-based detectors for cryo-electron microscopy of membrane and other proteins is described briefly, highlighting the strengths and weaknesses of the technique. Over the past few years CCD detectors have been used extensively in electron crystallography of membrane proteins, and in particular, in the study of the molecular transitions which take place during the photo-cycle of the light-driven proton pump bacteriorhodopsin. Direct-detection methods, which avoid the intermediate stages of converting the electron energy into light, offer the possibility of improved spatial resolution compared to CCD detectors; in addition, photon counting and noise-free readout should improve the signal-to-noise ratio

  15. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  16. A novel radiation detector for removing scattered radiation in chest radiography: Monte Carlo simulation-based performance evaluation

    Science.gov (United States)

    Roh, Y. H.; Yoon, Y.; Kim, K.; Kim, J.; Kim, J.; Morishita, J.

    2016-10-01

    Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.

  17. Characterization of a alpha particle detector CR-39 exposed to a source of radium

    International Nuclear Information System (INIS)

    Maino, Leandro Marcondes

    2009-01-01

    In this project, the main goal is the characterization of a alpha particle detector CR-39 exposed to a source of radio. Three detectors were exposed to a source of radium and then chemically treated for different periods. This way, we could analyze these samples and collect the information needed to verify that at least one of the chemical attack, there has been a separation of the energies alpha particles incident with distinct peaks, thus characterizing the CR-39 as alpha spectrometer in the range 2.5 to 6.3 MeV . (author)

  18. Monte Carlo simulations of the Galileo energetic particle detector

    CERN Document Server

    Jun, I; Garrett, H B; McEntire, R W

    2002-01-01

    Monte Carlo radiation transport studies have been performed for the Galileo spacecraft energetic particle detector (EPD) in order to study its response to energetic electrons and protons. Three-dimensional Monte Carlo radiation transport codes, MCNP version 4B (for electrons) and MCNPX version 2.2.3 (for protons), were used throughout the study. The results are presented in the form of 'geometric factors' for the high-energy channels studied in this paper: B1, DC2, and DC3 for electrons and B0, DC0, and DC1 for protons. The geometric factor is the energy-dependent detector response function that relates the incident particle fluxes to instrument count rates. The trend of actual data measured by the EPD was successfully reproduced using the geometric factors obtained in this study.

  19. Monte Carlo simulations of the Galileo energetic particle detector

    International Nuclear Information System (INIS)

    Jun, I.; Ratliff, J.M.; Garrett, H.B.; McEntire, R.W.

    2002-01-01

    Monte Carlo radiation transport studies have been performed for the Galileo spacecraft energetic particle detector (EPD) in order to study its response to energetic electrons and protons. Three-dimensional Monte Carlo radiation transport codes, MCNP version 4B (for electrons) and MCNPX version 2.2.3 (for protons), were used throughout the study. The results are presented in the form of 'geometric factors' for the high-energy channels studied in this paper: B1, DC2, and DC3 for electrons and B0, DC0, and DC1 for protons. The geometric factor is the energy-dependent detector response function that relates the incident particle fluxes to instrument count rates. The trend of actual data measured by the EPD was successfully reproduced using the geometric factors obtained in this study

  20. Recent progress in infrared detector technologies

    Science.gov (United States)

    Rogalski, A.

    2011-05-01

    In the paper, fundamental and technological issues associated with the development and exploitation of the most advanced infrared detector technologies are discussed. In this class of detectors both photon and thermal detectors are considered. Special attention is directed to HgCdTe ternary alloys on silicon, type-II superlattices, uncooled thermal bolometers, and novel uncooled micromechanical cantilever detectors. Despite serious competition from alternative technologies and slower progress than expected, HgCdTe is unlikely to be seriously challenged for high-performance applications, applications requiring multispectral capability and fast response. However, the nonuniformity is a serious problem in the case of LWIR and VLWIR HgCdTe detectors. In this context, it is predicted that type-II superlattice system seems to be an alternative to HgCdTe in long wavelength spectral region. In well established uncooled imaging, microbolometer arrays are clearly the most used technology. Present state-of-the-art microbolometers are based on polycrystalline or amorphous materials, typically vanadium oxide (VO x) or amorphous silicon (α-Si), with only modest temperature sensitivity and noise properties. Basic efforts today are mainly focused on pixel reduction and performance enhancement. Attractive alternatives consist of low-resistance α-SiGe monocrystalline SiGe quantum wells or quantum dots. In spite of successful commercialization of uncooled microbolometers, the infrared community is still searching for a platform for thermal imagers that combine affordability, convenience of operation, and excellent performance. Recent advances in MEMS systems have lead to the development of uncooled IR detectors operating as micromechanical thermal detectors. Between them the most important are biomaterial microcantilevers.

  1. Evaluation of a flat-panel detector system

    International Nuclear Information System (INIS)

    Sato, Masami; Eguchi, Yoichi; Yamada, Kinichi; Kaga, Yuji; Endo, Yutaka; Yamazaki, Tatsuya

    2001-01-01

    We evaluated the imaging performance of a flat-panel detector digital radiography system (CXDI-11 X-ray Digital Camera, Canon Inc.) and a computed radiography system (FCR9000C-HQ, Fuji Film). The characteristics of the two detectors and of the overall systems were compared. This included evaluation and comparison of the fundamental physical characteristics, including x-ray response curve, modulation transfer function (MTF), Wiener spectra, noise-equivalent quanta, and x-ray tube voltage-dependent detector response. Overall system performance was evaluated using receiver operating characteristic (ROC) analysis. The results of the study showed that the dynamic range of the CXDI-11 measured relative to the input x-ray flux was 10 3 , similar to that of the FCR9000C-HQ. Both systems showed similar final MTFs, although the pre-sampling MTF of the CXDI-11 was better than that of the FCR9000C-HQ. Noise analysis, based on noise-equivalent quanta and Wiener spectra, showed that for normal exposure conditions the CXDI-11 had superior performance. With both systems, x-ray response (system output/incident x-ray exposure) increased with increasing x-ray tube voltage. ROC analysis indicated that the CXDI-11 was superior in overall performance. (author)

  2. Semiconductor high-energy radiation scintillation detector

    International Nuclear Information System (INIS)

    Kastalsky, A.; Luryi, S.; Spivak, B.

    2006-01-01

    We propose a new scintillation-type detector in which high-energy radiation generates electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The key issue is how to make the semiconductor essentially transparent to its own infrared light, so that photons generated deep inside the semiconductor could reach its surface without tangible attenuation. We discuss two ways to accomplish this, one based on doping the semiconductor with shallow impurities of one polarity type, preferably donors, the other by heterostructure bandgap engineering. The proposed semiconductor scintillator combines the best properties of currently existing radiation detectors and can be used for both simple radiation monitoring, like a Geiger counter, and for high-resolution spectrography of the high-energy radiation. An important advantage of the proposed detector is its fast response time, about 1 ns, essentially limited only by the recombination time of minority carriers. Notably, the fast response comes without any degradation in brightness. When the scintillator is implemented in a qualified semiconductor material (such as InP or GaAs), the photo-detector and associated circuits can be epitaxially integrated on the scintillator slab and the structure can be stacked-up to achieve virtually any desired absorption capability

  3. Flat detectors and their clinical applications

    International Nuclear Information System (INIS)

    Spahn, Martin

    2005-01-01

    Diagnostic and interventional flat detector X-ray systems are penetrating the market in all application segments. First introduced in radiography and mammography, they have conquered cardiac and general angiography and are getting increasing attention in fluoroscopy. Two flat detector technologies prevail. The dominating method is based on an indirect X-ray conversion process, using cesium iodide scintillators. It offers considerable advantages in radiography, angiography and fluoroscopy. The other method employs a direct converter such as selenium which is particularly suitable for mammography. Both flat detector technologies are based on amorphous silicon active pixel matrices. Flat detectors facilitate the clinical workflow in radiographic rooms, foster improved image quality and provide the potential to reduce dose. This added value is based on their large dynamic range, their high sensitivity to X-rays and the instant availability of the image. Advanced image processing is instrumental in these improvements and expand the range of conventional diagnostic methods. In angiography and fluoroscopy the transition from image intensifiers to flat detectors is facilitated by ample advantages they offer, such as distortion-free images, excellent coarse contrast, large dynamic range and high X-ray sensitivity. These characteristics and their compatibility with strong magnetic fields are the basis for improved diagnostic methods and innovative interventional applications. (orig.)

  4. The Era of Kilometer-Scale Neutrino Detectors

    Directory of Open Access Journals (Sweden)

    Francis Halzen

    2013-01-01

    Full Text Available Neutrino astronomy beyond the Sun was first imagined in the late 1950s; by the 1970s, it was realized that kilometer-scale neutrino detectors were required. The first such instrument, IceCube, transforms a cubic kilometer of deep and ultra-transparent Antarctic ice into a particle detector. KM3NeT, an instrument that aims to exploit several cubic kilometers of the deep Mediterranean sea as its detector medium, is in its final design stages. The scientific missions of these instruments include searching for sources of cosmic rays and for dark matter, observing Galactic supernova explosions, and studying the neutrinos themselves. Identifying the accelerators that produce Galactic and extragalactic cosmic rays has been a priority mission of several generations of high-energy gamma-ray and neutrino telescopes; success has been elusive so far. Detecting the gamma-ray and neutrino fluxes associated with cosmic rays reaches a new watershed with the completion of IceCube, the first neutrino detector with sensitivity to the anticipated fluxes. In this paper, we will first revisit the rationale for constructing kilometer-scale neutrino detectors. We will subsequently recall the methods for determining the arrival direction, energy and flavor of neutrinos, and will subsequently describe the architecture of the IceCube and KM3NeT detectors.

  5. Discrimination and quantification of implanted solar wind in Genesis collector shards using grazing incidence synchrotron x-ray techniques: New detector initial results

    International Nuclear Information System (INIS)

    Kitts, K.; Choi, Y.; Sutton, S.R.; Ghose, S.; Burnett, D.; Eng, P.

    2008-01-01

    Accurate knowledge of the composition of the Sun provides a baseline, which allows an understanding of how the solar system has evolved over time and how solar processes and solar wind mechanics behave. Unfortunately, the errors in photospheric abundances are too large for many planetary science problems and this hampers our understanding of these different processes. Analyses of solar wind implanted in meteorites or lunar soils have provided more precise data [e.g. 1 and references therein] but the extent to which alteration processes on these bodies complicate such information is only now being determined. Therefore, in order to obtain pristine solar wind samples, NASA developed and launched the Genesis Discovery Mission. Unfortunately, the probe crash-landed shattering the 300 collector plates into 15,000+ pieces complicating the analysis and necessitating the development of new analytical techniques and equipment. Thus, shards from the Genesis collector array and their appropriate flight spares are currently being characterized via grazing-incidence synchrotron x-ray techniques at the Advanced Photon Source at Argonne National Laboratory. The goals are (1) determine solar wind fluences of the elements Ca-Ge by grazing-incidence angle-resolved x-ray fluorescence (XRF) and x-ray reflectivity, (2) improve data reduction via the development of XRF spectral deconvolution routines and develop modeling algorithms for reflectivity and fluorescence yield analysis in order to determine element specific depth profiles from which absolute concentration may be extracted and (3) designing and developing a new multi-element silicon multi-channel (SMCD) detector system. These improvements will increase our sensitivity by a factor of three or more, reduce measurement time at a given sensitivity to one-eighth and the minimum detection limit would be reduced by a factor of 3 to ∼3 x 10 8 atoms/cm 2 .

  6. Electronics for the RHIC PHENIX detector

    International Nuclear Information System (INIS)

    Young, G.R.

    1992-01-01

    The PHENIX detector for RHIC is being designed to measure lepton pairs, direct photons and hadrons emitted in collisions of heavy nuclei at center of mass energies up to 200 GeV/(nucleon-pair). The physics goal is tests of predictions concerning the existence and nature of a deconfined state of strongly-interacting matter. The relatively large final state multiplicities, which reach 1500 charged particles per unit of rapidity, place strong demands on detector segmentation and control of electronics cost and power consumption. An overview of present ideas concerning signal processing and data rates for PHENIX will be presented

  7. Correction of detector nonlinearity for the balloonborne Michelson Interferometer for Passive Atmospheric Sounding.

    Science.gov (United States)

    Kleinert, Anne

    2006-01-20

    The detectors used in the cryogenic limb-emission sounder MIPAS-B2 (Michelson Interferometer for Passive Atmospheric Sounding) show a nonlinear response, which leads to radiometric errors in the calibrated spectra if the nonlinearity is not taken into account. In the case of emission measurements, the dominant error that arises from the nonlinearity is the changing detector responsivity as the incident photon load changes. The effect of the distortion of a single interferogram can be neglected. A method to characterize the variable responsivity and to correct for this effect is proposed. Furthermore, a detailed error estimation is presented.

  8. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Christopher; Simon, Tom; Simon, Bill; Dempsey, James F.; Kahler, Darren; Palta, Jatinder R.; Liu Chihray; Yan Guanghua [Sun Nuclear Inc., 425-A Pineda Court, Melbourne, Florida 32940 and Department of Radiation Oncology, University of Florida, P.O. Box 100385, Gainesville, Florida 32610-0385 (United States); NRE, 202 Nuclear Science Building, University of Florida, P.O. Box 118300, Gainesville, Florida 32611-8300 and Sun Nuclear Inc., 425-A Pineda Court, Melbourne, Florida 32940 (United States); Sun Nuclear Inc., 425-A Pineda Court, Melbourne, Florida 32940 (United States); ViewRay Inc., 2 Thermo Fisher Way, Oakwood Village, Ohio 44146 (United States); Department of Radiation Oncology, University of Florida, P.O. Box 100385, Gainesville, Florida 32610-0385 (United States)

    2010-02-15

    Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm{sup 3} and a diode of surface area 0.64 mm{sup 2}. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm{sup 2} field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a {+-}0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping

  9. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

    International Nuclear Information System (INIS)

    Fox, Christopher; Simon, Tom; Simon, Bill; Dempsey, James F.; Kahler, Darren; Palta, Jatinder R.; Liu Chihray; Yan Guanghua

    2010-01-01

    Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm 3 and a diode of surface area 0.64 mm 2 . The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm 2 field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a ±0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in

  10. A New Virtual Point Detector Concept for a HPGe detector

    International Nuclear Information System (INIS)

    Byun, Jong In; Yun, Ju Yong

    2009-01-01

    For last several decades, the radiation measurement and radioactivity analysis techniques using gamma detectors have been well established. Especially , the study about the detection efficiency has been done as an important part of gamma spectrometry. The detection efficiency depends strongly on source-to-detector distance. The detection efficiency with source-to-detector distance can be expressed by a complex function of geometry and physical characteristics of gamma detectors. In order to simplify the relation, a virtual point detector concept was introduced by Notea. Recently, further studies concerning the virtual point detector have been performed. In previous other works the virtual point detector has been considered as a fictitious point existing behind the detector end cap. However the virtual point detector position for the front and side of voluminous detectors might be different due to different effective central axis of them. In order to more accurately define the relation, therefore, we should consider the virtual point detector for the front as well as side and off-center of the detector. The aim of this study is to accurately define the relation between the detection efficiency and source-to-detector distance with the virtual point detector. This paper demonstrates the method to situate the virtual point detectors for a HPGe detector. The new virtual point detector concept was introduced for three area of the detector and its characteristics also were demonstrated by using Monte Carlo Simulation method. We found that the detector has three virtual point detectors except for its rear area. This shows that we should consider the virtual point detectors for each area when applying the concept to radiation measurement. This concept can be applied to the accurate geometric simplification for the detector and radioactive sources.

  11. Magnetic field influences on the lateral dose response functions of photon-beam detectors: MC study of wall-less water-filled detectors with various densities.

    Science.gov (United States)

    Looe, Hui Khee; Delfs, Björn; Poppinga, Daniela; Harder, Dietrich; Poppe, Björn

    2017-06-21

    The distortion of detector reading profiles across photon beams in the presence of magnetic fields is a developing subject of clinical photon-beam dosimetry. The underlying modification by the Lorentz force of a detector's lateral dose response function-the convolution kernel transforming the true cross-beam dose profile in water into the detector reading profile-is here studied for the first time. The three basic convolution kernels, the photon fluence response function, the dose deposition kernel, and the lateral dose response function, of wall-less cylindrical detectors filled with water of low, normal and enhanced density are shown by Monte Carlo simulation to be distorted in the prevailing direction of the Lorentz force. The asymmetric shape changes of these convolution kernels in a water medium and in magnetic fields of up to 1.5 T are confined to the lower millimetre range, and they depend on the photon beam quality, the magnetic flux density and the detector's density. The impact of this distortion on detector reading profiles is demonstrated using a narrow photon beam profile. For clinical applications it appears as favourable that the magnetic flux density dependent distortion of the lateral dose response function, as far as secondary electron transport is concerned, vanishes in the case of water-equivalent detectors of normal water density. By means of secondary electron history backtracing, the spatial distribution of the photon interactions giving rise either directly to secondary electrons or to scattered photons further downstream producing secondary electrons which contribute to the detector's signal, and their lateral shift due to the Lorentz force is elucidated. Electron history backtracing also serves to illustrate the correct treatment of the influences of the Lorentz force in the EGSnrc Monte Carlo code applied in this study.

  12. Driver heterogeneity in rubbernecking behaviour at an incident site (poster)

    NARCIS (Netherlands)

    Rhasbudin Shah, S.M.; Knoop, V.L.; Hoogendoorn, S.P.

    2013-01-01

    Incidents can affect the flow in non?incident direction due to rubbernecking. To this date, only homogeneous rubbernecking behaviour has been assessed. This study provides insights into inter?driver heterogeneity in rubbernecking behaviour while passing an incident site. We use empirical trajectory

  13. Driver heterogeneity in rubbernecking behaviour at an incident site (abstract)

    NARCIS (Netherlands)

    Rhasbudin Shah, S.M.; Knoop, V.L.; Hoogendoorn, S.P.

    2013-01-01

    Incidents can affect the flow in non?incident direction due to rubbernecking. To this date, only homogeneous rubbernecking behaviour has been assessed. This study provides insights into inter?driver heterogeneity in rubbernecking behaviour while passing an incident site. We use empirical trajectory

  14. A multilayer surface detector for ultracold neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhehui, E-mail: zwang@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Hoffbauer, M.A.; Morris, C.L. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Callahan, N.B.; Adamek, E.R. [Indiana University, Bloomington, IN 47405 (United States); Bacon, J.D. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Blatnik, M. [Cleveland State University, Cleveland, OH 44115 (United States); Brandt, A.E. [North Carolina State University, Raleigh, NC 27695 (United States); Broussard, L.J.; Clayton, S.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Cude-Woods, C. [North Carolina State University, Raleigh, NC 27695 (United States); Currie, S. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Dees, E.B. [North Carolina State University, Raleigh, NC 27695 (United States); Ding, X. [Virginia Polytechnic Institute and State University, Blacksburg, VA 24061 (United States); Gao, J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Gray, F.E. [Regis University, Denver, CO 80221 (United States); Hickerson, K.P. [University of California Los Angeles, Los Angeles, CA 90095 (United States); Holley, A.T. [Tennessee Technological University, Cookeville, TN 38505 (United States); Ito, T.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Liu, C.-Y. [Indiana University, Bloomington, IN 47405 (United States); and others

    2015-10-21

    A multilayer surface detector for ultracold neutrons (UCNs) is described. The top {sup 10}B layer is exposed to vacuum and directly captures UCNs. The ZnS:Ag layer beneath the {sup 10}B layer is a few microns thick, which is sufficient to detect the charged particles from the {sup 10}B(n,α){sup 7}Li neutron-capture reaction, while thin enough that ample light due to α and {sup 7}Li escapes for detection by photomultiplier tubes. A 100-nm thick {sup 10}B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials, and other parameters. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparison with other existing {sup 3}He and {sup 10}B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.

  15. Simultaneous measurements of ion and electron currents using a novel compact electrostatic end-loss-current detector

    Science.gov (United States)

    Hirata, M.; Miyake, Y.; Cho, T.; Kohagura, J.; Numakura, T.; Shimizu, K.; Ito, M.; Kiminami, S.; Morimoto, N.; Hirai, K.; Yamagishi, T.; Miyata, Y.; Nakashima, Y.; Miyoshi, S.; Ogura, K.; Kondoh, T.; Kariya, T.

    2006-10-01

    For the purpose of end-loss-ion and -electron analyses in open-field plasmas, a compact-sized electrostatic end-loss-current detector is proposed on the basis of a self-collection principle for suppressing the effects of secondary-electron emission from a metal collector. For employing this specific method, it is worth noting that no further additional magnetic systems except the ambient open-ended magnetic fields are required in the detector operation. This characteristic property provides a compactness of the total detection system and availability for its use in plasma confinement devices without disturbing plasma-confining magnetic fields. The detector consists of a set of parallel metal plates with respect to lines of ambient magnetic forces of a plasma device for analyzing incident ion currents along with a grid for shielding the collector against strays due to the metal-plate biasing. The characterization experiments are carried out by the use of a test-ion-beam line along with an additional use of a Helmholtz coil system for the formation of open magnetic fields similar to those in the GAMMA 10 end region. The applications of the developed end-loss-current detector in the GAMMA 10 plasma experiments are demonstrated under the conditions with simultaneous incidence of energetic electrons produced by electron-cyclotron heatings for end-loss-plugging potential formation.

  16. Transmutation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Viererbl, L., E-mail: vie@ujv.c [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Lahodova, Z. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Klupak, V. [Nuclear Research Institute Rez plc (Czech Republic); Sus, F. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Kucera, J. [Research Centre Rez Ltd. (Czech Republic); Nuclear Physics Institute, Academy of Sciences of the Czech Republic (Czech Republic); Kus, P.; Marek, M. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic)

    2011-03-11

    We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.

  17. Transmutation detectors

    International Nuclear Information System (INIS)

    Viererbl, L.; Lahodova, Z.; Klupak, V.; Sus, F.; Kucera, J.; Kus, P.; Marek, M.

    2011-01-01

    We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.

  18. Design and performance of a lead fluoride detector as a luminosity monitor

    International Nuclear Information System (INIS)

    Pérez Benito, R.; Khaneft, D.; O'Connor, C.; Capozza, L.; Diefenbach, J.; Gläser, B.; Ma, Y.; Maas, F.E.; Rodríguez Piñeiro, D.

    2016-01-01

    Precise luminosity measurements for the OLYMPUS two-photon exchange experiment at DESY were performed by counting scattering events with alternating beams of electrons and positrons incident on atomic electrons in a gaseous hydrogen target. Final products of Møller, Bhabha, and pair annihilation interactions were observed using a pair of lead fluoride Cherenkov calorimeters with custom housings and electronics, adapted from a system used by the A4 parity violation experiment at MAMI. This paper describes the design, calibration, and operation of these detectors. An explanation of the Monte Carlo methods used to simulate the physical processes involved both at the scattering vertices and in the detector apparatus is also included.

  19. Design and performance of a lead fluoride detector as a luminosity monitor

    Energy Technology Data Exchange (ETDEWEB)

    Pérez Benito, R.; Khaneft, D. [Johannes Gutenberg-Universität, Mainz (Germany); O' Connor, C., E-mail: colton@mit.edu [Massachusetts Institute of Technology, Cambridge, MA (United States); Capozza, L. [Johannes Gutenberg-Universität, Mainz (Germany); Diefenbach, J. [Hampton University, Hampton, VA (United States); Gläser, B.; Ma, Y.; Maas, F.E.; Rodríguez Piñeiro, D. [Johannes Gutenberg-Universität, Mainz (Germany)

    2016-08-01

    Precise luminosity measurements for the OLYMPUS two-photon exchange experiment at DESY were performed by counting scattering events with alternating beams of electrons and positrons incident on atomic electrons in a gaseous hydrogen target. Final products of Møller, Bhabha, and pair annihilation interactions were observed using a pair of lead fluoride Cherenkov calorimeters with custom housings and electronics, adapted from a system used by the A4 parity violation experiment at MAMI. This paper describes the design, calibration, and operation of these detectors. An explanation of the Monte Carlo methods used to simulate the physical processes involved both at the scattering vertices and in the detector apparatus is also included.

  20. First results with the 4π charged particle detector INDRA at GANIL

    International Nuclear Information System (INIS)

    Dayras, R.

    1995-01-01

    After a three year construction period, the 4π charged particle detector INDRA took its first data at GANIL, during the spring of 1993. After a brief description of the detector characteristics, an overview of the ongoing scientific program is given. The general trend of the data are discussed. For the first time, the energy threshold for the full vaporization of a nuclear system into neutrons and Z=1 and 2 isotopes has been determined for the 36 Ar + 58 Ni reaction. For this system, this threshold is observed for an incident energy of about 50 A.MeV. (author). 18 refs., 6 figs

  1. Detector calibration measurements in CRESST

    Energy Technology Data Exchange (ETDEWEB)

    Westphal, W. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany)]. E-mail: westphal@ph.tum.de; Coppi, C. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Feilitzsch, F. von [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Isaila, C. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Jagemann, T. [Eberhard Karls Universitaet Tuebingen, Physikalisches Institut I, Auf der Morgenstelle 14, D-72076 Tuebingen (Germany); Jochum, J. [Eberhard Karls Universitaet Tuebingen, Physikalisches Institut I, Auf der Morgenstelle 14, D-72076 Tuebingen (Germany); Koenig, J. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Lachenmaier, T. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Lanfranchi, J.-C. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Potzel, W. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Rau, W. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Stark, M. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); Wernicke, D. [Technische Universitaet Muenchen, Physik Department E15, James-Franck-Strasse, D-85748 Garching (Germany); VeriCold Technologies GmbH, Bahnhofstrasse 21, D-85737 Ismaning (Germany)

    2006-04-15

    The CRESST dark matter experiment uses the simultaneous measurement of the scintillation light and the heat signal of a CaWO{sub 4} crystal to discriminate between background electron recoil and nuclear recoil events. At the Technical University of Munich calibration measurements have been performed to characterize the detectors. These measurements include the determination of the light output and scintillation time constants of CaWO{sub 4} at temperatures below 50 mK. The setup used in these measurements consist of a CaWO{sub 4} crystal, which is mounted in a reflective housing together with a silicon light detector carrying an Ir/Au transition edge sensor (TES) evaporated directly onto it.

  2. Detector Control System for the ATLAS Forward Proton detector

    CERN Document Server

    Czekierda, Sabina; The ATLAS collaboration

    2017-01-01

    The ATLAS Forward Proton (AFP) is a forward detector using a Roman Pot technique, recently installed in the LHC tunnel. It is aiming at registering protons that were diffractively or electromagnetically scattered in soft and hard processes. Infrastructure of the detector consists of hardware placed both in the tunnel and in the control room USA15 (about 330 meters from the Roman Pots). AFP detector, like the other detectors of the ATLAS experiment, uses the Detector Control System (DCS) to supervise the detector and to ensure its safe and coherent operation, since the incorrect detector performance may influence the physics results. The DCS continuously monitors the detector parameters, subset of which is stored in data bases. Crucial parameters are guarded by alarm system. A detector representation as a hierarchical tree-like structure of well-defined subsystems built with the use of the Finite State Machine (FSM) toolkit allows for overall detector operation and visualization. Every node in the hierarchy is...

  3. CVD polycrystalline diamond. A novel neutron detector and applications

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    1998-01-01

    Chemical Vapour Deposition (CVD) Polycrystalline Diamond film has been investigated as a low noise sensor for beta particles, gammas and neutrons using High Energy Physics technologies. Its advantages and disadvantages have been explored in comparison with other particle detectors such as silicon detector and other plastic scintillators. The performance and characteristic of the diamond detector have been fully studied and discussed. These studies will lead to a better understanding of how CVD diamonds perform as a detector and how to improve their performance under various conditions. A CVD diamond detector model has been proposed which is an attempt to explain the behaviour of such an extreme detector material. A novel neutron detector is introduced as a result of these studies. A good thermal and fast neutron detector can be fabricated with CVD diamond with new topologies. This detector will perform well without degradation in a high neutron radiation environment, as diamond is known to be radiation hard. It also offers better neutrons and gammas discrimination for high gamma background applications compared to other semiconductor detectors. A full simulation of the detector has also been done using GEANT, a Monte-Carlo simulation program for particle detectors. Simulation results show that CVD diamond detectors with this novel topology can detect neutrons with great directionality. Experimental work has been done on this detector in a nuclear reactor environment and accelerator source. A novel neutron source which offers a fast pulse high-energy neutrons has also been studied. With this detector, applications in neutron spectrometer for low-Z material have been pursued with various neutron detection techniques. One of these is a low-Z material identification system. The system has been designed and simulated for contraband luggage interrogation using the detector and the novel neutron source. Also other neutron related applications have been suggested. (author)

  4. CVD polycrystalline diamond. A novel neutron detector and applications

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    1998-07-01

    Chemical Vapour Deposition (CVD) Polycrystalline Diamond film has been investigated as a low noise sensor for beta particles, gammas and neutrons using High Energy Physics technologies. Its advantages and disadvantages have been explored in comparison with other particle detectors such as silicon detector and other plastic scintillators. The performance and characteristic of the diamond detector have been fully studied and discussed. These studies will lead to a better understanding of how CVD diamonds perform as a detector and how to improve their performance under various conditions. A CVD diamond detector model has been proposed which is an attempt to explain the behaviour of such an extreme detector material. A novel neutron detector is introduced as a result of these studies. A good thermal and fast neutron detector can be fabricated with CVD diamond with new topologies. This detector will perform well without degradation in a high neutron radiation environment, as diamond is known to be radiation-hard. It also offers better neutrons and gammas discrimination for high gamma background applications compared to other semiconductor detectors. A full simulation of the detector has also been done using GEANT, a Monte Carlo simulation program for particle detectors. Simulation results show that CVD diamond detectors with this novel topology can detect neutrons with great directionality. Experimental work has been done on this detector in a nuclear reactor environment and accelerator source. A novel neutron source which offers a fast pulse high-energy neutrons has also been studied. With this detector, applications in neutron spectrometry for low-Z material have been pursued with various neutron detection techniques. One of these is a low-Z material identification system. The system has been designed and simulated for contraband luggage interrogation using the detector and the novel neutron source. (author)

  5. Characterization of spectrometric photon-counting X-ray detectors at different pitches

    International Nuclear Information System (INIS)

    Jurdit, M.; Moulin, V.; Ouvrier-Buffet, P.; Verger, L.; Brambilla, A.; Radisson, P.

    2017-01-01

    There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm 2 . Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 10 6 incident photons.s −1 .mm −2 .

  6. [Calorimeter based detectors for high energy hadron colliders

    International Nuclear Information System (INIS)

    1992-01-01

    This document provides a progress report on research that has been conducted under DOE Grant DEFG0292ER40697 for the past year, and describes proposed work for the second year of this 8 year grant starting November 15, 1992. Personnel supported by the contract include 4 faculty, 1 research faculty, 4 postdocs, and 9 graduate students. The work under this grant has in the past been directed in two complementary directions -- DO at Fermilab, and the second SSC detector GEM. A major effort has been towards the construction and commissioning of the new Fermilab Collider detector DO, including design, construction, testing, the commissioning of the central tracking and the central calorimeters. The first DO run is now underway, with data taking and analysis of the first events. Trigger algorithms, data acquisition, calibration of tracking and calorimetry, data scanning and analysis, and planning for future upgrades of the DO detector with the advent of the FNAL Main Injector are all involved. The other effort supported by this grant has been towards the design of GEM, a large and general-purpose SSC detector with special emphasis on accurate muon measurement over a large solid angle. This effort will culminate this year in the presentation to the SSC laboratory of the GEM Technical Design Report. Contributions are being made to the detector design, coordination, and physics simulation studies with special emphasis on muon final states. Collaboration with the RD5 group at CERN to study muon punch through and to test cathode strip chamber prototypes was begun

  7. High Transverse Momentum Direct Photon Production at Fermilab Fixed-Target Energies

    International Nuclear Information System (INIS)

    Apanasevich, Leonard

    2005-01-01

    This thesis describes a study of the production of high transverse momentum direct photons and π 0 mesons by proton beams at 530 and 800 GeV/c and π - beams at 515 GeV/c incident on beryllium, copper, and liquid hydrogen targets. The data were collected by Fermilab experiment E706 during the 1990 and 1991-92 fixed target runs. The apparatus included a large, finely segmented lead and liquid argon electromagnetic calorimeter and a charged particle spectrometer featuring silicon strip detectors in the target region and proportional wire chambers and drift tubes downstream of a large aperture analysis magnet. The inclusive cross sections are presented as functions of transverse momentum and rapidity. The measurements are compared with next-to-leading order perturbative QCD calculations and to results from previous experiments

  8. High tracking resolution detectors. Final Technical Report

    International Nuclear Information System (INIS)

    Vasile, Stefan; Li, Zheng

    2010-01-01

    High-resolution tracking detectors based on Active Pixel Sensor (APS) have been valuable tools in Nuclear Physics and High-Energy Physics research, and have contributed to major discoveries. Their integration time, radiation length and readout rate is a limiting factor for the planed luminosity upgrades in nuclear and high-energy physics collider-based experiments. The goal of this program was to demonstrate and develop high-gain, high-resolution tracking detector arrays with faster readout, and shorter radiation length than APS arrays. These arrays may operate as direct charged particle detectors or as readouts of high resolution scintillating fiber arrays. During this program, we developed in CMOS large, high-resolution pixel sensor arrays with integrated readout, and reset at pixel level. Their intrinsic gain, high immunity to surface and moisture damage, will allow operating these detectors with minimal packaging/passivation requirements and will result in radiation length superior to APS. In Phase I, we designed and fabricated arrays with calorimetric output capable of sub-pixel resolution and sub-microsecond readout rate. The technical effort was dedicated to detector and readout structure development, performance verification, as well as to radiation damage and damage annealing.

  9. Straw detector: 1 - Vacuum: 0

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    The NA62 straw tracker is using pioneering CERN technology to measure charged particles from very rare kaon decays. For the first time, a large straw tracker with a 4.4 m2 coverage will be placed directly into an experiment’s vacuum tank, allowing physicists to measure the direction and momentum of charged particles with extreme precision. NA62 measurements using this technique will help physicists take a clear look at the kaon decay rate, which might be influenced by particles and processes that are not included in the Standard Model.   Straw ends are glued to an aluminium frame, a crucial step in the assembly of a module. The ends are then visually inspected before a leak test is performed.  “Although straw detectors have been around since the 1980s, what makes the NA62 straw trackers different is that they can work under vacuum,” explains Hans Danielsson from the PH-DT group leading the NA62 straw project. Straw detectors are basically small drift cha...

  10. Charge exchange reactions and the efficiency of solar neutrino detectors

    International Nuclear Information System (INIS)

    Austin, S.M.; Anantaraman, N.; Love, W.G.

    1994-01-01

    The efficiencies of solar neutrino detectors are often based in part on weak interaction strengths determined by (p,n) and other charge exchange reactions. Although the (p,n) determinations are surprisingly good, it is shown that they may be inaccurate for important Gamow-Teller transitions whose strengths are a small fraction of the sum rule limit. This emphasizes the importance of direct calibration with ν sources for detectors such as 127 I and 115 In where direct β-decay information cannot be obtained. It may also bear on recent attempts to compare charge exchange and beta decay in the mass-37 system

  11. Calibration of detector efficiency of neutron detector

    International Nuclear Information System (INIS)

    Guo Hongsheng; He Xijun; Xu Rongkun; Peng Taiping

    2001-01-01

    BF 3 neutron detector has been set up. Detector efficiency is calibrated by associated particle technique. It is about 3.17 x 10 -4 (1 +- 18%). Neutron yield of neutron generator per pulse (10 7 /pulse) is measured by using the detector

  12. Development of bonded semiconductor device for high counting rate high efficiency photon detectors

    International Nuclear Information System (INIS)

    Kanno, Ikuo

    2008-01-01

    We are trying to decrease dose exposure in medical diagnosis by way of measuring the energy of X-rays. For this purpose, radiation detectors for X-ray energy measurement with high counting rate should be developed. Direct bonding of Si wafers was carried out to make a radiation detector, which had separated X-ray absorber and detector. The resistivity of bonding interface was estimated with the results of four-probe measurements and model calculations. Direct bonding of high resistivity p and n-Si wafers was also performed. The resistance of the pn bonded diode was 0.7 MΩ. The resistance should be increased in the future. (author)

  13. Low-latency data analysis for the spherical detector Mario Schenberg

    International Nuclear Information System (INIS)

    Costa, Carlos Filipe Da Silva; Costa, César Augusto; Aguiar, Odylio Denys

    2014-01-01

    The confrontation of gravitational waves (GWs) with their electromagnetic (EM) counterparts will be rich with information about astrophysical events. Initially, this confrontation will corroborate GW detections; afterwards, when GW detections become more recurrent, it will allow astrophysics to combine information from different channels (GW, EM and also neutrinos). A low-latency data analysis which provides the direction of an incoming GW candidate is required to confront it with fast follow-up EM observations. Until now, no low-latency data analysis has been developed for spherical detectors. One spherical detector alone is capable of determining both the GW direction and polarization. By using this capability, we have developed a low-latency data analysis pipeline for the Mario Schenberg detector. This pipeline is able to retrieve the direction of GW triggers with an average angular resolution from δs ∼ 8° at SNR ∼ 12 to δs ∼ 1° at SNR ∼ 80, in a timespan of a 4 s for 32 s of data being analyzed. We apply a veto which reduces fake events up to 90% when maintaining the GW efficiency above 90% for high SNRs. We provide here a description of the method and its efficiency: resolution on the direction, false alarm rate and computational time. (paper)

  14. Ionization dual-zone static detector having single radioactive source

    International Nuclear Information System (INIS)

    Ried, L. Jr.; Wade, A.L.

    1977-01-01

    This ionization detector or combustion product detector includes a single radioactive source located in an ionization chamber, and the ionization chamber includes portions comprising a reference zone and a signal zone. Electrical circuitry connected to the reference and signal zones provides an output signal directly related to changes in voltages across the signal zone in relation to the amount of particulates of combustion present in the ionization chamber

  15. NA62 Gigatracker sets new standards for silicon detectors

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    The NA62 experiment should start collecting its first data (technical run) in a little over one year. At the heart of the experiment is the Gigatracker, a newly conceived silicon pixel detector, whose job is to measure the arrival time and the position of the incoming beam particles. The demonstration detector has recently shown a time resolution of 175 picoseconds, an unprecedented record in the field of silicon pixel detectors.   The Gigatracker prototype. A 115 metre long vacuum tank, a brand new set of detectors surrounding it and an extremely rare decay to study: this is the new NA62 detector, foreseen to be installed in the SPS North Area in 2012. “We will study a very rare decay of the K+. Such a decay is sensitive to contributions coming from new particles and therefore represents a powerful way of searching for new physics, complementary to the direct approach of the LHC detectors,” explains Augusto Ceccucci, NA62 spokesperson. The particles from the SPS accelerator a...

  16. Gaining efficiency and resolution in soft X-ray emission spectrometers thanks to directly illuminated CCD detectors

    International Nuclear Information System (INIS)

    Dinardo, M.E.; Piazzalunga, A.; Braicovich, L.; Bisogni, V.; Dallera, C.; Giarda, K.; Marcon, M.; Tagliaferri, A.; Ghiringhelli, G.

    2007-01-01

    The back-illuminated charge coupled devices (CCD) are suitable for soft X-ray photon detection. Their nominal performances suggest that they can boost both efficiency and resolving power of X-ray spectrometers based on diffraction gratings and two-dimensional position sensitive detectors. We tested the performances of two commercially available CCDs, intended to replace a more traditional microchannel plate (MCP) detector. Our tests show that the devices have excellent performances in terms of dark current, response linearity, detection efficiency and spatial resolution. We observed that the CCDs have better efficiency (more than 10 times) and better resolution (∼3 times) than the MCP. Moreover we found an intrinsic limit for the spatial resolution, which is almost independent of the detector pixel size and is estimated around 25 μm

  17. Particle Detectors: Research and Development at CERN

    International Nuclear Information System (INIS)

    Fabjan, C. W.

    2008-01-01

    Over the past 15 years a worldwide Detector R and D Programme has made the LHC experiments possible. These experiments operate at a new level of event rate and detection capabilities. Based on these advances, Detector R and D is continuing at CERN in close collaboration with University and Research Institutes. Several main directions are being pursued for solid-state and gaseous tracking devices, advanced crystal and noble liquid calorimetry, particle identification methods, and advanced signal-processing techniques. This effort is directed towards experiments at even higher collision rates at the LHC, the requirements for the next generation of linear electron-positron colliders and for applications outside particle physics, such as medical diagnostics instrumentation. We shall illustrate this challenging, stimulating and creative programme with examples and show how these developments are taking place in close collaboration between CERN and institutions around the globe

  18. Characterization of a radiation detector for aircraft measurements

    International Nuclear Information System (INIS)

    Holanda M, L. de; Federico, C. A.; Caldas, L. V. E.

    2014-08-01

    Air crews, as pilots and flight attendants, are subjected to cosmic ray doses which can be higher than the average doses on workers from the nuclear industry. The diversity of particles of high energies present in the radiation field on board of air crafts turns the determination of the incident dose difficult, and requires special care regarding dosimetric systems to be used in this kind of radiation field. The Brazilian Air Force, through its Institute for Advanced Studies (Instituto de Estudos Avancados, IEAv/DCTA) in conjunction with the Institute of Energetic and Nuclear Research (Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP) are working on this subject since 2008. A prototype of a radiation detector for aircraft measurements was previously built and tested in flight and laboratory conditions. The detector is able of measuring a quantity known as absorbed dose (using passive dosimeters), which will subsequently be correlated to the ambient dose equivalent and the effective dose received by air crews. In this context, a theoretical approach through Monte Carlo simulations with the computational codes MCNP5 and MCNPX was used to model and characterize the detector response at such experimental conditions. This work presents the preliminary results of the computational modeling, with special emphasis on the comparison between the absorbed doses measured and simulated, and its relationship with the ambient dose equivalent and the effective dose for this detector. (author)

  19. Characterization of a radiation detector for aircraft measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holanda M, L. de; Federico, C. A.; Caldas, L. V. E., E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares, Av. Lineu Prestes 2242, Cidade Universitaria, CEP 05508-000, Sao Paulo (Brazil)

    2014-08-15

    Air crews, as pilots and flight attendants, are subjected to cosmic ray doses which can be higher than the average doses on workers from the nuclear industry. The diversity of particles of high energies present in the radiation field on board of air crafts turns the determination of the incident dose difficult, and requires special care regarding dosimetric systems to be used in this kind of radiation field. The Brazilian Air Force, through its Institute for Advanced Studies (Instituto de Estudos Avancados, IEAv/DCTA) in conjunction with the Institute of Energetic and Nuclear Research (Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP) are working on this subject since 2008. A prototype of a radiation detector for aircraft measurements was previously built and tested in flight and laboratory conditions. The detector is able of measuring a quantity known as absorbed dose (using passive dosimeters), which will subsequently be correlated to the ambient dose equivalent and the effective dose received by air crews. In this context, a theoretical approach through Monte Carlo simulations with the computational codes MCNP5 and MCNPX was used to model and characterize the detector response at such experimental conditions. This work presents the preliminary results of the computational modeling, with special emphasis on the comparison between the absorbed doses measured and simulated, and its relationship with the ambient dose equivalent and the effective dose for this detector. (author)

  20. Performance of the CMS Phase 1 Pixel Detector

    CERN Document Server

    Akgun, Bora

    2018-01-01

    It is anticipated that the LHC accelerator will reach and exceed the luminosity of L = 2$\\times$10$^{34}$cm$^{-2}$s$^{-1}$ during the LHC Run 2 period until 2023. At this higher luminosity and increased hit occupancies the CMS phase-0 pixel detector would have been subjected to severe dead time and inefficiencies introduced by limited buffers in the analog read-out chip and effects of radiation damage in the sensors. Therefore a new pixel detector has been built and replaced the phase-0 detector in the 2016/17 LHC extended year-end technical stop. The CMS phase-1 pixel detector features four central barrel layers and three end-cap disks in forward and backward direction for robust tracking performance, and a significantly reduced overall material budget including new cooling and powering schemes. The design of the new front-end readout chip comprises larger data buffers, an increased transmission bandwidth, and low-threshold comparators. These improvements allow the new pixel detector to sustain and improve t...

  1. Utilization Of Carbon Nanotubes In Electromagnetic Wave Detectors

    Directory of Open Access Journals (Sweden)

    Muhammad Hanis Zakariah

    2017-08-01

    Full Text Available Direct detection of hydrocarbon by an active source using electromagnetic (EM energy termed seabed logging (SBL has shown very promising results. However, currently available electromagnetic wave technology has a number of challenges include sensitivity and frequency matching. This paper presents development of the carbon nanotubes (CNTs as electromagnetic wave detector due to outstanding properties of carbon nanotubes. They are currently one of the desired materials for advanced technologies. Two types of detectors were developed in this work, carbon nanotube-based (D1 and without nanotube-based (D2 detectors. Various configuration and arrangement for each type of detector were investigated to determine the one with the highest detection measurement and stability of frequency stability of detection system. It was found that 20 turn-coils coil placed at its centre gives the maximum detection of induction voltage, 39.61 mV. However, the 20 turn- coils with CNTs which gives 36.50 mV is the preferred EM detectors due to the stability in frequency of the detection system.

  2. GaN-Based Detector Enabling Technology for Next Generation Ultraviolet Planetary Missions

    Science.gov (United States)

    Aslam, S.; Gronoff, G.; Hewagama, T.; Janz, S.; Kotecki, C.

    2012-01-01

    The ternary alloy AlN-GaN-InN system provides several distinct advantages for the development of UV detectors for future planetary missions. First, (InN), (GaN) and (AlN) have direct bandgaps 0.8, 3.4 and 6.2 eV, respectively, with corresponding wavelength cutoffs of 1550 nm, 365 nm and 200 nm. Since they are miscible with each other, these nitrides form complete series of indium gallium nitride (In(sub l-x)Ga(sub x)N) and aluminum gallium nitride (Al(sub l-x)Ga(sub x)N) alloys thus allowing the development of detectors with a wavelength cut-off anywhere in this range. For the 2S0-365 nm spectral wavelength range AlGaN detectors can be designed to give a 1000x solar radiation rejection at cut-off wavelength of 325 nm, than can be achieved with Si based detectors. For tailored wavelength cut-offs in the 365-4S0 nm range, InGaN based detectors can be fabricated, which still give 20-40x better solar radiation rejection than Si based detectors. This reduced need for blocking filters greatly increases the Detective Quantum efficiency (DQE) and simplifies the instrument's optical systems. Second, the wide direct bandgap reduces the thermally generated dark current to levels allowing many observations to be performed at room temperature. Third, compared to narrow bandgap materials, wide bandgap semiconductors are significantly more radiation tolerant. Finally, with the use of an (AI, In)GaN array, the overall system cost is reduced by eliminating stringent Si CCD cooling systems. Compared to silicon, GaN based detectors have superior QE based on a direct bandgap and longer absorption lengths in the UV.

  3. Configuration Design of Detector Shielding for Gamma Prompt Analysis

    International Nuclear Information System (INIS)

    Elin-Nuraini; Darsono; Elisabeth

    2000-01-01

    Configuration on design of detector shielding for gamma prompt analysishas been performed. The aim of this design is to obtain effective shieldingmaterial and configuration that able to protect the detector for fastneutron. The result shown that detector shielding configuration that obtainedby configuration of water and concrete, would be able to absorb fast neutronup to 99.5 %. The neutron flux that passed through shielding configuration is2.4 x 10 3 n/cm 2 dt, in the detector position of 60 cm (forward neutron beamdirection) on the X axis and 30 cm (side ward neutron beam direction) on theZ axis of target. On this position (60,30) counting result was 104358 for Pbcollimator and 246652 for PVC collimator. From examination result shown thatthe weight of silicon is in order 175 gram. (author)

  4. Vertically etched silicon nano-rods as a sensitive electron detector

    International Nuclear Information System (INIS)

    Hajmirzaheydarali, M; Akbari, M; Soleimani-Amiri, S; Sadeghipari, M; Shahsafi, A; Akhavan Farahani, A; Mohajerzadeh, S

    2015-01-01

    We have used vertically etched silicon nano-rods to realize electron detectors suitable for scanning electron microscopes. The results of deep etching of silicon nano-structures are presented to achieve highly ordered arrays of nano-rods. The response of the electron detector to energy of the primary electron beam and the effects of various sizes and materials has been investigated, indicating its high sensitivity to secondary and back-scattered electrons. The miniaturized structure of this electron detector allows it to be placed in the vicinity of the specimen to improve the resolution and contrast. This detector collects electrons and converts the electron current to voltage directly by means of n-doped silicon nano-rods on a p-type silicon substrate. Silicon nano-rods enhance the surface-to-volume ratio of the detector as well as improving the yield of electron detection. The use of nano-structures and silicon nanowires as an electron detector has led to higher sensitivities than with micro-structures. (paper)

  5. Semidetector-radiation detector arrangement, as well as its application in a tomographic scanner, in a device to determine radiation intensity or to measure the radiation penetration or absorption

    International Nuclear Information System (INIS)

    Kaufman, L.; Hosier, K.E. Jr.

    1979-01-01

    The CdTe detector or a plate with several CdTe or HgI 2 detectors is suitable for use in computer controlled tomographic X-ray scanners. The detector is used in connection with a pulsed radiation source (Am 241) and a frequency filter technique for measuring the resulting electrical charge pulse of the detector. Merely a narrow frequency band is selected according to the measured duration of the incident radiation pulses. (DG) [de

  6. Monte Carlo simulation of the X-ray response of a germanium microstrip detector with energy and position resolution

    CERN Document Server

    Rossi, G; Fajardo, P; Morse, J

    1999-01-01

    We present Monte Carlo computer simulations of the X-ray response of a micro-strip germanium detector over the energy range 30-100 keV. The detector consists of a linear array of lithographically defined 150 mu m wide strips on a high purity monolithic germanium crystal of 6 mm thickness. The simulation code is divided into two parts. We first consider a 10 mu m wide X-ray beam striking the detector surface at normal incidence and compute the interaction processes possible for each photon. Photon scattering and absorption inside the detector crystal are simulated using the EGS4 code with the LSCAT extension for low energies. A history of events is created of the deposited energies which is read by the second part of the code which computes the energy histogram for each detector strip. Appropriate algorithms are introduced to account for lateral charge spreading occurring during charge carrier drift to the detector surface, and Fano and preamplifier electronic noise contributions. Computed spectra for differen...

  7. Alpha-particle dosimetry using solid state nuclear track detectors. Application to 222Rn and its daughters

    International Nuclear Information System (INIS)

    Barillon, R.; Chambaudet, A.

    2000-01-01

    A methodology for the determination of the detection efficiency of a solid state nuclear track detector for radon and its short-lived daughters was presented. First, particular attention is paid to the α-particles having energies and angles of incidence that lead to observable tracks after an adapted chemical etching. The results are then incorporated in a mathematical model to determine the theoretical radon detection efficiency of a polymeric detector placed in a cylindrical cell. When applied to LR115 and CR39 detectors, the model reveals the influence of the position of the radon daughters inside the cell. Radon daughters tend to link up with natural atmospheric aerosols and then settle on the cell's inside wall. This model allows to determine, among other things, the cell size for which the detector response is independent of the fraction daughters plated out. (author)

  8. Modeling of clover detector in addback mode

    Science.gov (United States)

    Kshetri, R.

    2012-07-01

    Based on absorption and scattering of gamma-rays, a formalism has been presented for modeling the clover germanium detector in addback mode and to predict its response for high energy γ-rays. In the present formalism, the operation of a bare clover detector could be described in terms of three quantities only. Considering an additional parameter, the formalism could be extended for suppressed clover. Using experimental data on relative single crystal efficiency and addback factor as input, the peak-to-total ratio has been calculated for three energies (Eγ = 3.401, 5.324 and 10.430 MeV) where direct measurement of peak-to-total ratio is impossible due to absence of a radioactive source having single monoenergetic gamma-ray of that energy. The experimental validation and consistency of the formalism have been shown considering data for TIGRESS clover detector. In a recent work (R. Kshetri, JINST 2012 7 P04008), we showed that for a given γ-ray energy, the formalism could be used to predict the peak-to-total ratio as a function of number of detector modules. In the present paper, we have shown that for a given composite detector (clover detector is considered here), the formalism could be used to predict the peak-to-total ratio as a function of γ-ray energy.

  9. Modeling of clover detector in addback mode

    International Nuclear Information System (INIS)

    Kshetri, R

    2012-01-01

    Based on absorption and scattering of gamma-rays, a formalism has been presented for modeling the clover germanium detector in addback mode and to predict its response for high energy γ-rays. In the present formalism, the operation of a bare clover detector could be described in terms of three quantities only. Considering an additional parameter, the formalism could be extended for suppressed clover. Using experimental data on relative single crystal efficiency and addback factor as input, the peak-to-total ratio has been calculated for three energies (E γ = 3.401, 5.324 and 10.430 MeV) where direct measurement of peak-to-total ratio is impossible due to absence of a radioactive source having single monoenergetic gamma-ray of that energy. The experimental validation and consistency of the formalism have been shown considering data for TIGRESS clover detector. In a recent work (R. Kshetri, JINST 2012 7 P04008), we showed that for a given γ-ray energy, the formalism could be used to predict the peak-to-total ratio as a function of number of detector modules. In the present paper, we have shown that for a given composite detector (clover detector is considered here), the formalism could be used to predict the peak-to-total ratio as a function of γ-ray energy.

  10. Radiation detectors laboratory; Laboratorio de detectores de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez J, F.J. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The Radiation detectors laboratory was established with the assistance of the International Atomic Energy Agency which gave this the responsibility to provide its services at National and regional level for Latin America and it is located at the ININ. The more expensive and delicate radiation detectors are those made of semiconductor, so it has been put emphasis in the use and repairing of these detectors type. The supplied services by this laboratory are: selection consultant, detectors installation and handling and associated systems. Installation training, preventive and corrective maintenance of detectors and detection systems calibration. (Author)

  11. Design criteria for a hemispherical detector for LET measurements

    International Nuclear Information System (INIS)

    Schell, M.C.; DeLuca, P.M. Jr.; Pearson, D.W.; Attix, F.H.

    1980-01-01

    A detector for the direct measurement of the Linear Energy Transfer (LET) in cylindrical geometry was developed by Brandan and DeLuca. The detector successfully measured the LET of protons and a fraction of the heavy charged particles generated in cylindrical A150 plastic and graphite walls by 14.8 MeV neutrons. In this report, we present design tests for the hemispherical LET detector which will measure the LET of charged particles in spherical geometry and allow comparison with calculated LET spectra. The hemispherical LET detector will also provide a data base for radiobiological predictions with the Track Structure Model by Katz. A comparison of predictions of radiobiological effects by the Theory of Dual Radiation Action and the Track Structure Model by Edwards and the authors indicate that the Track Structure Model predicts cell survival as a function of dose more accurately and hence an additional motivation for the present construction of the hemispherical LET detector

  12. Smoke detectors

    International Nuclear Information System (INIS)

    Fung, C.K.

    1981-01-01

    This describes a smoke detector comprising a self-luminous light source and a photosensitive device which is so arranged that the light source is changed by the presence of smoke in a detecting region. A gaseous tritium light source is used. This consists of a borosilicate glass bulb with an internal phosphor coating, filled with tritium gas. The tritium emits low energy beta particles which cause the phosphor to glow. This is a reliable light source which needs no external power source. The photosensitive device may be a phototransistor and may drive a warning device through a directly coupled transistor amplifier. (U.K.)

  13. Ionization Collection in Detectors of the Cryogenic Dark Matter Search

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, Arran T.J. [Univ. of California, Berkeley, CA (United States)

    2016-01-01

    Determining the composition of dark matter is at the forefront of modern scientific research. There is compelling evidence for the existence of vast quantities of dark matter throughout the universe, however it has so-far eluded all direct detection efforts and its identity remains a mystery. Weakly interacting massive particles (WIMPs) are a favored dark matter candidate and have been the primary focus of direct detection for several decades. The Cryogenic Dark Matter Search (CDMS) has developed the Z-dependent Ionization and Phonon (ZIP) detector to search for such particles. Typically made from germanium, these detectors are capable of distinguishing between electromagnetic background and a putative WIMP signal through the simultaneous measurement of ionization and phonons produced by scattering events. CDMS has operated several arrays of these detectors at the Soudan Underground Laboratory (Soudan, MN, USA) resulting in many competitive (often world-leading) WIMP exclusion limits. This dissertation focuses on ionization collection in these detectors under the sub-Kelvin, low electric field, and high crystal purity conditions unique to CDMS. The design and performance of a fully cryogenic HEMT-based amplifier capable of achieving the SuperCDMS SNOLAB ionization energy resolution goal of 100 eVee is presented. The experimental apparatus which has been used to record electron and hole properties under CDMS conditions is described. Measurements of charge transport, trapping, and impact ionization as a function of electric field in two CDMS detectors are shown, and the ionization collection efficiency is determined. The data is used to predict the error in the nuclear recoil energy scale under both CDMSlite and iZIP operating modes. A two species, two state model is developed to describe how ionization collection and space charge generation in CDMS detectors are controlled by the presence of “overcharged” D- donor and A+ acceptor impurity states. The thermal

  14. The Daya Bay antineutrino detector filling system and liquid mass measurement

    Science.gov (United States)

    Band, H. R.; Cherwinka, J. J.; Draeger, E.; Heeger, K. M.; Hinrichs, P.; Lewis, C. A.; Mattison, H.; McFarlane, M. C.; Webber, D. M.; Wenman, D.; Wang, W.; Wise, T.; Xiao, Q.

    2013-09-01

    The Daya Bay Reactor Neutrino Experiment has measured the neutrino mixing angle θ13 to world-leading precision. The experiment uses eight antineutrino detectors filled with 20-tons of gadolinium-doped liquid scintillator to detect antineutrinos emitted from the Daya Bay nuclear power plant through the inverse beta decay reaction. The precision measurement of sin22θ13 relies on the relative antineutrino interaction rates between detectors at near (400 m) and far (roughly 1.8 km) distances from the nuclear reactors. The measured interaction rate in each detector is directly proportional to the number of protons in the liquid scintillator target. A precision detector filling system was developed to simultaneously fill the three liquid zones of the antineutrino detectors and measure the relative target mass between detectors to < 0.02%. This paper describes the design, operation, and performance of the system and the resulting precision measurement of the detectors' target liquid masses.

  15. SIRI - A proposal for a multi-detector ΔE-E particle telescope

    International Nuclear Information System (INIS)

    Guttormsen, M.

    1992-06-01

    The CACTUS detector system which is mounted on the 90 o beam line of the Oslo Cyclotron consists of 28 NaI and 2 Ge detectors in combination with 8 Si particle telescopes. The Si particle telescopes are however based on an old technology with a geometrical lay-out that prohibits further increase in efficiency. In this report a replacement of the old system in the form of 64 telescopes based on silicon strip detectors is proposed. For the planned system called SIRI (Silicon Ring), the detectors are located on a ring around the target, covering the angles between 30 o and 60 o relative to the beam direction. The planned detector system will increase detector efficiency of charged particles by a factor 8. The design and construction of the new detector system is described and discussed. 8 refs., 9 figs., 4 tabs

  16. Time dispersion in large plastic scintillation neutron detector [Paper No.:B3

    International Nuclear Information System (INIS)

    De, A.; Dasgupta, S.S.; Sen, D.

    1993-01-01

    Time dispersion seen by photomultiplier (PM) tube in large plastic scintillation neutron detector and the light collection mechanism by the same have been computed showing that this time dispersion (TD) seen by the PM tube does not necessarily increase with increasing incident neutron energy in contrast to the usual finding that TD increases with increasing energy. (author). 8 refs., 4 figs

  17. Detector and System Developments for LHC Detector Upgrades

    CERN Document Server

    Mandelli, Beatrice; Guida, Roberto; Rohne, Ole; Stapnes, Steinar

    2015-05-12

    The future Large Hadron Collider (LHC) Physics program and the consequent improvement of the LHC accelerator performance set important challenges to all detector systems. This PhD thesis delineates the studies and strategies adopted to improve two different types of detectors: the replacement of precision trackers with ever increasingly performing silicon detectors, and the improvement of large gaseous detector systems by optimizing their gas mixtures and operation modes. Within the LHC tracker upgrade programs, the ATLAS Insertable B-layer (IBL) is the first major upgrade of a silicon-pixel detector. Indeed the overall ATLAS Pixel Detector performance is expected to degrade with the increase of luminosity and the IBL will recover the performance by adding a fourth innermost layer. The IBL Detector makes use of new pixel and front-end electronics technologies as well as a novel thermal management approach and light support and service structures. These innovations required complex developments and Quality Ass...

  18. A rotation-symmetric, position-sensitive annular detector for maximum counting rates

    International Nuclear Information System (INIS)

    Igel, S.

    1993-12-01

    The Germanium Wall is a semiconductor detector system containing up to four annular position sensitive ΔE-detectors from high purity germanium (HPGe) planned to complement the BIG KARL spectrometer in COSY experiments. The first diode of the system, the Quirl-detector, has a two dimensional position sensitive structure defined by 200 Archimedes' spirals on each side with opposite orientation. In this way about 40000 pixels are defined. Since each spiral element detects almost the same number of events in an experiment the whole system can be optimized for maximal counting rates. This paper describes a test setup for a first prototype of the Quirl-detector and the results of test measurements with an α-source. The detector current and the electrical separation of the spiral elements were measured. The splitting of signals due to the spread of charge carriers produced by an incident ionizing particle on several adjacent elements was investigated in detail and found to be twice as high as expected from calculations. Its influence on energy and position resolution is discussed. Electronic crosstalk via signal wires and the influence of noise from the magnetic spectrometer has been tested under experimental conditions. Additionally, vacuum feedthroughs based on printed Kapton foils pressed between Viton seals were fabricated and tested successfully concerning their vacuum and thermal properties. (orig.)

  19. Discrimination of Charged Particles in a Neutral Beam Line by Using a Solid Scintillation Detector

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jong-Kwan; Ko, Jewou; Liu, Dong [Jeju National University, Jeju (Korea, Republic of)

    2017-01-15

    In the past several decades, many studies have been conducted to search for non-baryonic dark matter, such as weakly interactive massive particles (WIMPs). In the search for WIMPs, charged particles incident on the detector are background particles because WIMPs are neutral. Charged particles originate from various sources, such as cosmic rays and laboratory materials surrounding the main detector. Therefore, a veto that discriminates charged particles can improve the particle detection efficiency of the entire experiment for detecting WIMPs. Here, we investigate in the thickness range of 1 mm to 5 mm, the optimal thickness of a polystyrene scintillator as a charged particle veto detector. We found that 3-mm-thick polystyrene provides the best performance to veto charged particles and the charged-particle background in the search for the WIMP signal. Furthermore, we fabricated 3-mm-thick and 5-mm-thick polystyrene charged particle veto detectors that will be used in an underground laboratory in the search for WIMP dark matter. After exposing those detectors are the actual beam line, we compared the rate of charged particles measured using those detectors and the rate simulated through a Monte Carlo simulation.

  20. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  1. Pulse shape analysis for the gamma-ray tracking detector Agata

    International Nuclear Information System (INIS)

    Olariu, A.

    2007-10-01

    Agata is the European project for a 4π gamma-ray tracking array of 180 Ge detectors and is expected to have a detection sensitivity higher by 3 orders of magnitude than that of the present generation of gamma spectrometers. The trajectories of the photons inside a Ge crystal are reconstituted, which allows the determination of the initial energy of the incident photons as the total energy deposited along the track. The sequence of a γ-ray scattering process is too fast compared with the time resolution of the detector to be measured electronically, so tracking algorithms are necessary. Gamma-ray tracking detectors are operating in position sensitive mode it means that Ge crystal are segmented in order to facilitate the localization of the gamma interactions. It is possible to improve the position resolution by using the information conveyed by the shape of the detector signal. The task of the PSA (Pulse Shape Analysis) algorithm is to analyze this signal and extract the number of interactions, the position and the energy of each interaction. PSA algorithms rely on a basis of reference signals given by single interactions and that are obtained through an experimental characterization of the detector with scanning systems. The matrix method is a new PSA algorithm that consists in fitting linearly the detector signal with a set of calculated signals. We have tested this method with both simulated and measured signals. In the case of simulated single interactions the position resolution is 1.4 mm which is within Agata's specifications. For measured signals we have obtained mean positional errors of 3.2 mm at the front end of the detector an 4.8 mm at the back end

  2. Application of MOSFET radiation detector for patient dosimetry

    International Nuclear Information System (INIS)

    Soubra, M.; Cygler, J.; Szanto, J.

    1996-01-01

    Purpose: A new direct reading Metal Oxide-Silicon Field Effect Transistor (MOSFET) based radiation detector system has been investigated in a variety of clinical radiotherapy procedures. The aim of this study is to report on the clinical applicability of such a device, its ease of use and on its dosimetric properties that include precision angular and energy dependence. Comparisons of patient dose measurements obtained by the MOSFET based system and the commonly used thermoluminescence dosimeters (TLD) and diodes are discussed. Material and Methods: A commercially available MOSFET dosimetry system that employs dual MOSFET dual bias arrangements has been used in this study. The detector is bonded with the epoxy to the end of a long (1.5 m) flexible cable whose other end is connected to a bias supply box operated by a battery. The bias box can accommodate up to 5 MOSFETs and after radiation exposure the dose can be determined by connecting the detectors to a pre calibrated reader. For the clinical evaluation 5 MOSFETs were used on patients undergoing total body irradiation (TBI) and high dose rate brachytherapy (HDR). The MOSFET detectors were taped to patient surface adjacent to the routinely used TLDs and/or diodes. To examine energy dependence the MOSFET sensitivity (mV/Gy) was determined in relation to a calibrated dose from 6 and 18 MV photon beams. The directional dependence was investigated by placing a MOSFET during irradiation in a special polystyrene insert that can be manually rotated to the required angle. Precision (reproducibility) measurements were made by exposing MOSFETs to multiple fractions of dose in the range of 3 x 10 -2 to 2 Gy. Results: In 3 of TBI trials the diodes measured average dose was within 1.0% of the prescribed dose compared to 3.7% for TLDs and 1.8% for MOSFETs. The MOSFETs average sensitivity for 6 MV was within 2% of the 18 MV photon beam. The reproducibility of MOSFET response was better than 3 % provided the dose per fraction is

  3. Timing characteristics of a two-dimensional multi-wire cathode strip detector for fission fragments

    International Nuclear Information System (INIS)

    Vind, R.P.; Joshi, B.N.; Jangale, R.V.; Inkar, A.L.; Prajapati, G.K.; John, B.V.; Biswas, D.C.

    2014-01-01

    In the recent past, a gas filled two-dimensional multi-wire cathode strip detector (MCSD) was developed for the detection of fission fragments (FFs). The position resolution was found to be about 1.0 and 1.5 mm in X and Y directions respectively. The detector has three electrode planes consisting of cathode strip (X-plane), anode wires and split-cathode wires (Y-plane). Each thin wire of the anode plane placed between the two cathode planes is essentially independent and behaves like a proportional counter. The construction of the detector in detail has been given in our earlier paper. The position information has been obtained by employing high impedance discrete delay line read out method for extracting position information in X and Y-directions. In this work, the timing characteristics of MCSD detector are reported to explore the possible use of this detector for the measurement of the mass of the fission fragments produced in heavy ion induced fission reactions

  4. Laser amplitude stabilization for advanced interferometric gravitational wave detectors

    International Nuclear Information System (INIS)

    Barr, B W; Strain, K A; Killow, C J

    2005-01-01

    We present results of experiments into the stabilization of the amplitude of Nd:YAG lasers for use in advanced gravitational wave detectors. By feeding back directly to the pump-diode driving current we achieved shot-noise-limited stabilization at frequencies up to several kHz with some residual noise at lower frequencies (sub ∼100 Hz). The method used is applicable to higher powered laser systems planned for advanced interferometric gravitational wave detectors

  5. Defect kinetics in novel detector materials

    CERN Document Server

    MacEvoy, B C

    2000-01-01

    Silicon particle detectors will be used extensively in experiments at the CERN Large Hadron Collider, where unprecedented particle fluences will cause significant atomic displacement damage. We present a model of the evolution of defect concentrations and consequent electrical behaviour in "novel" detector materials with various oxygen and carbon impurity concentrations. The divacancy-oxygen (V/sub 2/O) defect is identified as the cause of changes in device characteristics during /sup 60/Co gamma irradiation. In the case of hadron irradiation changes in detector doping concentration (N/sub eff/) are dominated by cluster defects, in particular the divacancy (V/sub 2/), which exchange charge directly via a non-Shockley-Read- Hall mechanism. The V/sub 2/O defect also contributes to Ne/sub eff/. This defect is more copiously produced during 24 GeV/c proton irradiation than during 1 MeV neutron irradiation on account of the higher vacancy introduction rate, hence the radiation hardness of materials is more sensiti...

  6. Large area self-powered gamma ray detector

    International Nuclear Information System (INIS)

    LeVert, F.E.

    1994-01-01

    The purpose of this research was to develop a large area self-powered gamma detector (LASPGD) capable of detecting the movement of sealed radiation sources into and out of industrial radiographic units and to construct a prototype source position monitor (SPM) for these units utilizing the LASPGD. Prototype isotropic and directional LASPGDs, with solid and inert gas dielectrics, were developed and extensively tested using calibrated gamma sources (i.e., Cs-137, and Co-60). The sensitivities of the isotropic detectors, with inert gas dielectrics, were found to be approximately a factor of ten greater than those measured for the solid dielectric LASPGDs. Directionally sensitive self-powered detectors were found to exhibit a forward-to-back hemispherical sensitivity ratio of approximately 2 to 1. Industrial radiographic units containing Ir-192 sources with different activities were used to test the performance of the SPM. The SPM, which utilized a gas dielectric LASPGD, performed as designed. That is, the current generated in the LASPGD was converted to a voltage, amplified and used to control the on/off state of an incandescent lamp. The incandescent lamp, which functions as the source/out warning indicator, flashes at a rate of one flash per second when the source is in use (i.e. out of its shield)

  7. Direct detection of dark matter with the EDELWEISS-III experiment: signals induced by charge trapping, data analysis and characterization of cryogenic detector sensitivity to low-mass WIMPs

    International Nuclear Information System (INIS)

    Arnaud, Quentin

    2015-01-01

    The EDELWEISS-III experiment is dedicated to direct dark matter searches aiming at detecting WIMPS. These massive particles should account for more than 80% of the mass of the Universe and be detectable through their elastic scattering on nuclei constituting the absorber of a detector. As the expected WIMP event rate is extremely low ( 20 GeV). Finally, a study dedicated to the optimization of solid cryogenic detectors to low mass WIMP searches is presented. This study is performed on simulated data using a statistical test based on a profiled likelihood ratio that allows for statistical background subtraction and spectral shape discrimination. This study combined with results from Run308, has lead the EDELWEISS experiment to favor low mass WIMP searches ( [fr

  8. The Liquid Argon Calorimeter system for the SLC Large Detector

    International Nuclear Information System (INIS)

    Haller, G.M.; Fox, J.D.; Smith, S.R.

    1988-09-01

    In this paper the physical packaging and the logical organization of the Liquid Argon Calorimeter (LAC) electronics system for the Stanford Linear Collider Large Detector (SLD) at SLAC are described. This system processes signals from approximately 44,000 calorimeter towers and is unusual in that most electronic functions are packaged within the detector itself as opposed to an external electronics support rack. The signal path from the towers in the liquid argon through the vacuum to the outside of the detector is explained. The organization of the control logic, analog electronics, power regulation, analog-to-digital conversion circuits, and fiber optic drivers mounted directly on the detector are described. Redundancy considerations for the electronics and cooling issues are discussed. 12 refs., 5 figs

  9. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  10. The FPGA Pixel Array Detector

    International Nuclear Information System (INIS)

    Hromalik, Marianne S.; Green, Katherine S.; Philipp, Hugh T.; Tate, Mark W.; Gruner, Sol M.

    2013-01-01

    A proposed design for a reconfigurable x-ray Pixel Array Detector (PAD) is described. It operates by integrating a high-end commercial field programmable gate array (FPGA) into a 3-layer device along with a high-resistivity diode detection layer and a custom, application-specific integrated circuit (ASIC) layer. The ASIC layer contains an energy-discriminating photon-counting front end with photon hits streamed directly to the FPGA via a massively parallel, high-speed data connection. FPGA resources can be allocated to perform user defined tasks on the pixel data streams, including the implementation of a direct time autocorrelation function (ACF) with time resolution down to 100 ns. Using the FPGA at the front end to calculate the ACF reduces the required data transfer rate by several orders of magnitude when compared to a fast framing detector. The FPGA-ASIC high-speed interface, as well as the in-FPGA implementation of a real-time ACF for x-ray photon correlation spectroscopy experiments has been designed and simulated. A 16×16 pixel prototype of the ASIC has been fabricated and is being tested. -- Highlights: ► We describe the novelty and need for the FPGA Pixel Array Detector. ► We describe the specifications and design of the Diode, ASIC and FPGA layers. ► We highlight the Autocorrelation Function (ACF) for speckle as an example application. ► Simulated FPGA output calculates the ACF for different input bitstreams to 100 ns. ► Reduced data transfer rate by 640× and sped up real-time ACF by 100× other methods.

  11. A performance comparison of direct- and indirect-detection flat-panel imagers

    International Nuclear Information System (INIS)

    Partridge, M.; Hesse, B.-M.; Mueller, L.

    2002-01-01

    A comparison of the performance of a direct- and an indirect-detection amorphous silicon flat-panel X-ray imager is presented for a 6 MV beam. Experimental measurements of the noise characteristics, image lag, spectral response, spatial resolution and quantum efficiency are described, compared and discussed. The two systems are comprised of 512x512 pixel, 400 μm pitch, arrays of a-Si:H p-i-n photodiodes and thin-film transistors. In the direct-detection system, X-rays interact to produce electron/hole pairs directly in the silicon photodiodes. For the indirect-detection system, a phosphor screen converts energy from the incident X-rays into visible light, which is then detected by the photodiodes. Both systems are shown to be quantum noise limited, with the total electronic noise in the detector 10-15 times smaller than the Poisson noise level in detected signal. The measured lag for both systems is 1.0±0.1% or less in the first frame with subsequent signals decaying exponentially with frame read-out, with a half-life of between 3.3 and 3.8 frames. Both systems are demonstrated to have a pronounced sensitivity to low-energy multiply scattered photons, although this is shown to be effectively filtered out using a 2 mm copper build-up plate. The direct-detection system, with the 2 mm Cu build-up, shows greater sensitivity to scattered radiation than the indirect system. The spatial resolutions of both systems were effectively equal with an f 50 of 0.25 mm -1 when pixels are binned 2x2, although a slight contribution from optical scattering in the phosphor screen is seen for the indirect-detection system. The quantum efficiency of the direct-detection system is a factor of 0.45 lower than that of the indirect-detection system. The application of these detectors to megavoltage CT is discussed, with the conclusion that the indirect-detection system is to be preferred

  12. Contamination detector for inner surface of container

    International Nuclear Information System (INIS)

    Watanabe, Tadao.

    1995-01-01

    The present invention concerns a device for detecting contamination of radioactive materials on the inner surface of a vessel upon reutilizing the vessel for containing solidified radioactive wastes and transporting them. Namely, the detecting device has following functions. (1) A radiation detector detects the radioactive materials on the inner surface of the vessel. (2) A plurality of proximity switches measure the distance from the radiation detector to the wall surface of the vessel and are actuated if the distance is decreased to a predetermined value, (3) A vessel inner surface position calculation mechanism calculates the position of the inner surface of the vessel based on the information from a direction indicator and a height indicator. (4) A frontal limit detector detects the limit for allowing the radiation detector to proceed. (5) A vessel inner shape judging mechanism for judging the shape of the inner side of the vessel based on the signals from the proximity switches in a state where the frontal limit detector is operated and a vessel inner surface position signal outputted from the vessel inner surface position calculation mechanism. As a result, the shape of the inner side of the vessel can accurately be recognized, thereby improving accuracy of radiation measurement. (I.S.)

  13. Arrival time and incidence angle distributions of extensive air showers (EAS) muons

    International Nuclear Information System (INIS)

    Brancus, I.M.; Duma, M.; Vulpescu, B.; Foeller, M.; Rebel, H.; Voelker, G.; Chilingarian, A.A.

    1995-01-01

    The arrival time distributions of the muons can be related to the longitudinal EAS development and may provide additional information about the nature of the primary. Based on EAS simulations using the Monte-Carlo code CORSIKA, the correlations between arrival time and incidence angle distributions have been investigated in a case of a set of ideal detectors (10 m x 10 m) placed at various distances from the shower core. Applying advanced statistical techniques based on Bayes decision rule and non-parametric multivariate analysing methods it turns out that the correlations of muon arrival time and incidence angle at various separating distances of about 50 m exhibit promising features for mass discrimination (author)

  14. Data for First Responder Use of Photoionization Detectors for Vapor Chemical Constituents

    Energy Technology Data Exchange (ETDEWEB)

    Keith A. Daum; Matthew G. Watrous; M. Dean Neptune; Daniel I. Michael; Kevin J. Hull; Joseph D. Evans

    2006-11-01

    First responders need appropriate measurement technologies for evaluating incident scenes. This report provides information about photoionization detectors (PIDs), obtained from manufacturers and independent laboratory tests, and the use of PIDs by first responders, obtained from incident commanders in the United States and Canada. PIDs are valued for their relatively low cost, light weight, rapid detection response, and ease of use. However, it is clear that further efforts are needed to provide suitable instruments and decision tools to incident commanders and first responders for assessing potential hazardous chemical releases. Information provided in this report indicates that PIDs should always be part of a decision-making context in which other qualitative and more definitive tests and instruments are used to confirm a finding. Possible amelioratory actions ranging from quick and relatively easy fixes to those requiring significant additional effort are outlined in the report.

  15. Comparing interaction rate detectors for weakly interacting massive particles with annual modulation detectors

    International Nuclear Information System (INIS)

    Copi, Craig J.; Krauss, Lawrence M.

    2003-01-01

    We compare the sensitivity of WIMP detection via direct separation of possible signal versus background to WIMP detection via detection of an annual modulation, in which signal and background cannot be separated on an event-by-event basis. In order to determine how the constraints from the two different types of experiments might be combined an adequate incorporation of uncertainties due to galactic halo models must be made. This issue is particularly timely in light of recent direct detection limits from Edelweiss and CDMS, which we now demonstrate cannot be made consistent with the most recent claimed DAMA annual modulation observation by including halo uncertainties for spin independent interactions. On the other hand, we demonstrate that a combination of these two techniques, in the event of any positive direct detection signal, could ultimately allow significant constraints on anisotropic halo models even without directional sensitivity in these detectors

  16. Progress on uncooled PbSe detectors for low-cost applications

    Science.gov (United States)

    Vergara, German; Gomez, Luis J.; Villamayor, Victor; Alvarez, M.; Rodrigo, Maria T.; del Carmen Torquemada, Maria; Sanchez, Fernando J.; Verdu, Marina; Diezhandino, Jorge; Rodriguez, Purificacion; Catalan, Irene; Almazan, Rosa; Plaza, Julio; Montojo, Maria T.

    2004-08-01

    This work reports on progress on development of polycrystalline PbSe infrared detectors at the Centro de Investigacion y Desarrollo de la Armada (CIDA). Since mid nineties, the CIDA owns an innovative technology for processing uncooled MWIR detectors of polycrystalline PbSe. Based on this technology, some applications have been developed. However, future applications demand smarter, more complex, faster yet cheaper detectors. Aiming to open new perspectives to polycrystalline PbSe detectors, we are currently working on different directions: 1) Processing of 2D arrays: a) Designing and processing low density x-y addressed arrays with 16x16 and 32x32 elements, as an extension of our standard technology. b) Trying to make compatible standard CMOS and polycrystalline PbSe technologies in order to process monolithic large format arrays. 2) Adding new features to the detector such as monolithically integrated spectral discrimination.

  17. Future Perspectives for the Application of Low Temperature Detectors in Heavy Ion Physics

    International Nuclear Information System (INIS)

    Egelhof, P.; Kraft-Bermuth, S.

    2009-01-01

    Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics is given, and the next generation heavy ion facility FAIR is described with a special emphasis on the potential advantage of Low Temperature Detectors (LTDs) for applications in heavy ion physics. For prototype LTDs for the energy sensitive detection of heavy ions excellent results with respect to energy resolution down to δE/E = 1-2x10 -3 for a wide range of incident energies, and with respect to other detector properties, such as energy linearity with no indication of pulse height defects even for the heaviest ions, have been obtained. In addition, prototype detectors for hard X-rays have shown energy resolutions down to δE = 30-40eV at 60 keV. Consequently, both detector schemes have already been successfully used for first experiments. At present, the design and setup of large solid angle detector arrays is in progress. With the already achieved performance, LTDs promise a large potential for applications in atomic and nuclear heavy ion physics. A brief overview of prominent examples, including high-resolution nuclear spectroscopy, nuclear structure studies with radioactive beams, superheavy element research, as well as high-resolution atomic spectroscopy on highly charged ions and tests of QED in strong electromagnetic fields is presented.

  18. Life Finder Detectors: An Overview of Detector Technologies for Detecting Life on Other Worlds

    Science.gov (United States)

    Rauscher, Bernard J.; Domagal-Goldman, Shawn; Greenhouse, Matthew A.; Hsieh, Wen-Ting; McElwain, Michael W.; Moseley, Samuel H.; Noroozian, Omid; Norton, Tim; Kutyrev, Alexander; Rinehart, Stephen; stock, Joseph

    2015-01-01

    Future large space telescopes will seek evidence for life on other worlds by searching for spectroscopic biosignatures. Atmospheric biosignature gases include oxygen, ozone, water vapor, and methane. Non-biological gases, including carbon monoxide and carbon dioxide, are important for discriminating false positives. All of these gases imprint spectroscopic features in the UV through mid-IR that are potentially detectable using future space based coronagraphs or star shades for starlight suppression.Direct spectroscopic biosignature detection requires sensors capable of robustly measuring photon arrival rates on the order of 10 per resolution element per hour. Photon counting is required for some wavefront sensing and control approaches to achieve the requisite high contrast ratios. We review life finder detector technologies that either exist today, or are under development, that have the potential to meet these challenging requirements. We specifically highlight areas where more work or development is needed.Life finder detectors will be invaluable for a wide variety of other major science programs. Because of its cross cutting nature; UV, optical, and infrared (UVOIR) detector development features prominently in the 2010 National Research Council Decadal Survey, 'New Worlds, New Horizons in Astronomy and Astrophysics', and the NASA Cosmic Origins Program Technology Roadmap.

  19. Development and characterization of a neutron detector based on a lithium glass–polymer composite

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, M.; Nattress, J.; Kukharev, V.; Foster, A.; Meddeb, A. [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Trivelpiece, C. [Materials Research Institute, The Pennsylvania State University, University Park, PA 16802 (United States); Ounaies, Z. [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Jovanovic, I., E-mail: ijovanovic@psu.edu [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802 (United States)

    2015-06-11

    We report on the fabrication and characterization of a neutron scintillation detector based on a Li-glass–polymer composite that utilizes a combination of pulse height and pulse shape discrimination (PSD) to achieve high gamma rejection. In contrast to fast neutron detection in a PSD medium, we combine two scintillating materials that do not possess inherent neutron/gamma PSD properties to achieve effective PSD/pulse height discrimination in a composite material. Unlike recoil-based fast neutron detection, neutron/gamma discrimination can be robust even at low neutron energies due to the high Q-value neutron capture on {sup 6}Li. A cylindrical detector with a 5.05 cm diameter and 5.08 cm height was fabricated from scintillating 1 mm diameter Li-glass rods and scintillating polyvinyltoluene. The intrinsic efficiency for incident fission neutrons from {sup 252}Cf and gamma rejection of the detector were measured to be 0.33% and less than 10{sup −8}, respectively. These results demonstrate the high selectivity of the detector for neutrons and provide motivation for prototyping larger detectors optimized for specific applications, such as detection and event-by-event spectrometry of neutrons produced by fission.

  20. Recent Results from Beam Tests of 3D and Pad pCVD Diamond Detectors

    CERN Document Server

    Wallny, Rainer

    2017-01-01

    Results from prototypes of a detector using chemical vapor deposited (CVD) diamond with embedded resistive electrodes in the bulk forming a 3D diamond device are presented. A detector system consisting of 3D devices based on poly-crystalline CVD (pCVD) diamond was connected to a multi-channel readout and successfully tested in a 120 GeV/c proton beam at CERN proving for the first time the feasibility of the 3D detector concept in pCVD for particle tracking applications. We also present beam test results on the dependence of signal size on incident particle rate in charged particle detectors based on poly-crystalline CVD diamond. The detectors were tested in a 260 MeV/c pion beam over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2 . The pulse height of the sensors was measured with pad readout electronics at a peaking time of 7 ns. Our data from the 2015 beam tests at PSI indicate that the pulse height of poly-crystalline CVD diamond sensor irradiated to 5×1014 neq/cm2 is independent of particle flux...

  1. PICsIT a position sensitive detector for space applications

    CERN Document Server

    Labanti, C; Ferriani, S; Ferro, G; Malaguti, G; Mauri, A; Rossi, E; Schiavone, F; Stephen, J B; Traci, A; Visparelli, D

    2002-01-01

    Pixellated Imaging CsI Telescope (PICsIT) is the high energy detector plane of Imager on Board INTEGRAL Satellite (IBIS), one of the main instruments on board the International Gamma-Ray Astrophysics Laboratory (INTEGRAL) satellite that will be launched in the year 2001. It consists of 4096 CsI(Tl) individual detector elements and operates in the energy range from 120 to 10,000 keV. PICsIT is made up of 8 identical modules, each housing 512 scintillating crystals coupled to PIN photodiodes (PD). Each crystal, 30 mm long and with a cross-section of 8.55x8.55 mm sup 2 , is wrapped with a white diffusing coating and then inserted into an aluminium crate. In order to have a compact design, two electronic boards, mounted directly below the crystal/PD assembly, host both the Analogue and Digital Front-End Electronics (FEE). The behaviour of the read-out FEE has a direct impact on the performance of the whole detector in terms of lower energy threshold, energy resolution and event time tagging. Due to the great numb...

  2. Assessment of MODIS RSB Detector Uniformity Using Deep Convective Clouds

    Science.gov (United States)

    Chang, Tiejun; Xiong, Xiaoxiong (Jack); Angal, Amit; Mu, Qiaozhen

    2016-01-01

    For satellite sensor, the striping observed in images is typically associated with the relative multiple detector gain difference derived from the calibration. A method using deep convective cloud (DCC) measurements to assess the difference among detectors after calibration is proposed and demonstrated for select reflective solar bands (RSBs) of the Moderate Resolution Imaging Spectroradiometer (MODIS). Each detector of MODIS RSB is calibrated independently using a solar diffuser (SD). Although the SD is expected to accurately characterize detector response, the uncertainties associated with the SD degradation and characterization result in inadequacies in the estimation of each detector's gain. This work takes advantage of the DCC technique to assess detector uniformity and scan mirror side difference for RSB. The detector differences for Terra MODIS Collection 6 are less than 1% for bands 1, 3-5, and 18 and up to 2% for bands 6, 19, and 26. The largest difference is up to 4% for band 7. Most Aqua bands have detector differences less than 0.5% except bands 19 and 26 with up to 1.5%. Normally, large differences occur for edge detectors. The long-term trending shows seasonal oscillations in detector differences for some bands, which are correlated with the instrument temperature. The detector uniformities were evaluated for both unaggregated and aggregated detectors for MODIS band 1 and bands 3-7, and their consistencies are verified. The assessment results were validated by applying a direct correction to reflectance images. These assessments can lead to improvements to the calibration algorithm and therefore a reduction in striping observed in the calibrated imagery.

  3. Charge sharing in silicon pixel detectors

    CERN Document Server

    Mathieson, K; Seller, P; Prydderch, M L; O'Shea, V; Bates, R L; Smith, K M; Rahman, M

    2002-01-01

    We used a pixellated hybrid silicon X-ray detector to study the effect of the sharing of generated charge between neighbouring pixels over a range of incident X-ray energies, 13-36 keV. The system is a room temperature, energy resolving detector with a Gaussian FWHM of 265 eV at 5.9 keV. Each pixel is 300 mu m square, 300 mu m deep and is bump bonded to matching read out electronics. The modelling packages MEDICI and MCNP were used to model the complete X-ray interaction and the subsequent charge transport. Using this software a model is developed which reproduces well the experimental results. The simulations are then altered to explore smaller pixel sizes and different X-ray energies. Charge sharing was observed experimentally to be 2% at 13 keV rising to 4.5% at 36 keV, for an energy threshold of 4 keV. The models predict that up to 50% of charge may be lost to the neighbouring pixels, for an X-ray energy of 36 keV, when the pixel size is reduced to 55 mu m.

  4. The TORCH time-of-flight detector

    Energy Technology Data Exchange (ETDEWEB)

    Harnew, N., E-mail: Neville.Harnew@physics.ox.ac.uk [University of Oxford, Denys Wilkinson Building, 1 Keble Road, Oxford OX1 3RH (United Kingdom); Brook, N. [University College London, Department of Physics & Astronomy, Gower Street, London WC1E 6BT (United Kingdom); Castillo García, L. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Laboratory for High Energy Physics, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Cussans, D. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Föhl, K.; Forty, R.; Frei, C. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Gao, R. [University of Oxford, Denys Wilkinson Building, 1 Keble Road, Oxford OX1 3RH (United Kingdom); Gys, T.; Piedigrossi, D. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Rademacker, J.; Ros Garcia, A.; Dijk, M. van [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom)

    2016-07-11

    The TORCH time-of-flight detector is being developed to provide particle identification between 2 and 10 GeV/c momentum over a flight distance of 10 m. TORCH is designed for large-area coverage, up to 30 m{sup 2}, and has a DIRC-like construction. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple Cherenkov photons produced within quartz radiator plates of 10 mm thickness. A four-year R&D programme is underway with an industrial partner (Photek, UK) to produce 53×53 mm{sup 2} Micro-Channel Plate (MCP) detectors for the TORCH application. The MCP-PMT will provide a timing accuracy of 40 ps per photon and it will have a lifetime of up to at least 5 Ccm{sup −2} of integrated anode charge by utilizing an Atomic Layer Deposition (ALD) coating. The MCP will be read out using charge division with customised electronics incorporating the NINO chipset. Laboratory results on prototype MCPs are presented. The construction of a prototype TORCH module and its simulated performance are also described.

  5. Isotropic irradiation of detectors from point sources

    DEFF Research Database (Denmark)

    Aage, Helle Karina

    1997-01-01

    NaI(Tl) scintillator detectors have been exposed to gamma rays from 8 different point sources from different directions. Background and backscatter of gamma-rays from the surroundings have been subtracted in order to produce clean spectra. By adding spectra obtained from exposures from different ...

  6. Direct measurement of homogeneously distributed radioactive air contamination with germanium detectors

    International Nuclear Information System (INIS)

    Sowa, W.

    1990-01-01

    Air contamination by γ emitting radionuclides was measured with a vertically arranged germanium detector, laterally shielded by a lead ring, and calibration factors and detection limits of a number of fission products determined. The possibility of measuring simultaneously existing air and soil contamination by measurements with and without lead shield is described. The change of detection limit of air contamination is presented for different soil contamination levels by the same radionuclide. Calibration factors are given to determine the dose rate on the ground due to air contamination by different radionuclides. (author)

  7. A first principle approach for clover detector

    Science.gov (United States)

    Kshetri, R.

    2012-08-01

    A simple model based on probability flow arguments has been presented for understanding the clover germanium detector. Using basic concepts of absorption and scattering of gamma-rays, the operation of the clover detector has been described in terms of six probability amplitudes and a parameter. Instead of using an empirical method or simulation, this work presents the first attempt to calculate the peak-to-total and peak-to-background ratios of the clover detector using experimental data of relative single crystal efficiency and addback factor as an input. A unique feature of our approach is that these ratios could be calculated for energies where their direct measurement is impossible due to absence of a radioactive source having single monoenergetic gamma-ray of that energy. Results for four gamma-ray energies (Eγ = 1.408, 3.907, 7.029 and 10.430 MeV) have been discussed. Agreement between experimental data and analysis results has been observed. The present approach could describe clover-type detectors as well. As an example, the nine element detector has been considered. We have demonstrated that our formalism can describe both finite and infinite interactions of γ-rays with the clover crystals. The work presented in this paper follows similar philosophy as presented in a recent paper (R. Kshetri, JInst 2012 7 P04008), which deals with modeling of encapsulated type composite detectors like miniball, cluster and SPI (Spectrometer for INTEGRAL satellite).

  8. A first principle approach for clover detector

    International Nuclear Information System (INIS)

    Kshetri, R

    2012-01-01

    A simple model based on probability flow arguments has been presented for understanding the clover germanium detector. Using basic concepts of absorption and scattering of gamma-rays, the operation of the clover detector has been described in terms of six probability amplitudes and a parameter. Instead of using an empirical method or simulation, this work presents the first attempt to calculate the peak-to-total and peak-to-background ratios of the clover detector using experimental data of relative single crystal efficiency and addback factor as an input. A unique feature of our approach is that these ratios could be calculated for energies where their direct measurement is impossible due to absence of a radioactive source having single monoenergetic gamma-ray of that energy. Results for four gamma-ray energies (E γ = 1.408, 3.907, 7.029 and 10.430 MeV) have been discussed. Agreement between experimental data and analysis results has been observed. The present approach could describe clover-type detectors as well. As an example, the nine element detector has been considered. We have demonstrated that our formalism can describe both finite and infinite interactions of γ-rays with the clover crystals. The work presented in this paper follows similar philosophy as presented in a recent paper (R. Kshetri, JInst 2012 7 P04008), which deals with modeling of encapsulated type composite detectors like miniball, cluster and SPI (Spectrometer for INTEGRAL satellite).

  9. An Efficient, FPGA-Based, Cluster Detection Algorithm Implementation for a Strip Detector Readout System in a Time Projection Chamber Polarimeter

    Science.gov (United States)

    Gregory, Kyle J.; Hill, Joanne E. (Editor); Black, J. Kevin; Baumgartner, Wayne H.; Jahoda, Keith

    2016-01-01

    A fundamental challenge in a spaceborne application of a gas-based Time Projection Chamber (TPC) for observation of X-ray polarization is handling the large amount of data collected. The TPC polarimeter described uses the APV-25 Application Specific Integrated Circuit (ASIC) to readout a strip detector. Two dimensional photoelectron track images are created with a time projection technique and used to determine the polarization of the incident X-rays. The detector produces a 128x30 pixel image per photon interaction with each pixel registering 12 bits of collected charge. This creates challenging requirements for data storage and downlink bandwidth with only a modest incidence of photons and can have a significant impact on the overall mission cost. An approach is described for locating and isolating the photoelectron track within the detector image, yielding a much smaller data product, typically between 8x8 pixels and 20x20 pixels. This approach is implemented using a Microsemi RT-ProASIC3-3000 Field-Programmable Gate Array (FPGA), clocked at 20 MHz and utilizing 10.7k logic gates (14% of FPGA), 20 Block RAMs (17% of FPGA), and no external RAM. Results will be presented, demonstrating successful photoelectron track cluster detection with minimal impact to detector dead-time.

  10. Electron crystallography with the EIGER detector

    Directory of Open Access Journals (Sweden)

    Gemma Tinti

    2018-03-01

    Full Text Available Electron crystallography is a discipline that currently attracts much attention as method for inorganic, organic and macromolecular structure solution. EIGER, a direct-detection hybrid pixel detector developed at the Paul Scherrer Institut, Switzerland, has been tested for electron diffraction in a transmission electron microscope. EIGER features a pixel pitch of 75 × 75 µm2, frame rates up to 23 kHz and a dead time between frames as low as 3 µs. Cluster size and modulation transfer functions of the detector at 100, 200 and 300 keV electron energies are reported and the data quality is demonstrated by structure determination of a SAPO-34 zeotype from electron diffraction data.

  11. Superconducting microresonator detectors for neutrino physics in Milano

    International Nuclear Information System (INIS)

    Ferri, E; Faverzani, M; Giachero, A; Nizzolo, R; Nucciotti, A; Day, P; LeDuc, H G; Falferi, P; Giordano, C; Marghesin, B; Mattedi, F; Mezzena, R

    2014-01-01

    Superconducting microwave microresonators are low temperature detectors compatible with large-scale multiplexed frequency domain readout. Our aim is to adapt and further advance the technology of microresonator detectors to develop new devices applied to the problem of measuring the neutrino mass. More specifically, we aim to develop detector arrays which can be applied to the calorimetric measurement of the energy spectra of 163 Ho EC decay (Q ∼ 2-3 keV) for a direct measurement of the neutrino mass. In order to achieve this goal, a study aimed to the selection of the best design and material for the detectors is required. A recent advance in microwave microresonator technology was the discovery that some metal nitrides, such as TiN, possess properties consistent with very high detector sensitivity. In this contribution, our progress on the design and test of Ti/TiN multilayer films is presented. We report measurements made on stoichiometric TiN, sub-stoichiometric TiN and multilayer Ti/TiN films including the critical temperature, the gap parameter and the quasi-particle recombination time extrapolated from ∼keV X-ray pulses.

  12. Cyber Incidents Involving Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Robert J. Turk

    2005-10-01

    information available to Department of Homeland Security (DHS) and others who require it. This report summarizes the rise in frequency of cyber attacks, describes the perpetrators, and identifies the means of attack. This type of analysis, when used in conjunction with vulnerability analyses, can be used to support a proactive approach to prevent cyber attacks. CSSC will use this document to evolve a standardized approach to incident reporting and analysis. This document will be updated as needed to record additional event analyses and insights regarding incident reporting. This report represents 120 cyber security incidents documented in a number of sources, including: the British Columbia Institute of Technology (BCIT) Industrial Security Incident Database, the 2003 CSI/FBI Computer Crime and Security Survey, the KEMA, Inc., Database, Lawrence Livermore National Laboratory, the Energy Incident Database, the INL Cyber Incident Database, and other open-source data. The National Memorial Institute for the Prevention of Terrorism (MIPT) database was also interrogated but, interestingly, failed to yield any cyber attack incidents. The results of this evaluation indicate that historical evidence provides insight into control system related incidents or failures; however, that the limited available information provides little support to future risk estimates. The documented case history shows that activity has increased significantly since 1988. The majority of incidents come from the Internet by way of opportunistic viruses, Trojans, and worms, but a surprisingly large number are directed acts of sabotage. A substantial number of confirmed, unconfirmed, and potential events that directly or potentially impact control systems worldwide are also identified. Twelve selected cyber incidents are presented at the end of this report as examples of the documented case studies (see Appendix B).

  13. Silicon detectors

    International Nuclear Information System (INIS)

    Klanner, R.

    1984-08-01

    The status and recent progress of silicon detectors for high energy physics is reviewed. Emphasis is put on detectors with high spatial resolution and the use of silicon detectors in calorimeters. (orig.)

  14. Flexible X-ray detector based on sliced lead iodide crystal

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hui; Gao, Xiuying [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu (China); Department of Materials Science, Sichuan University, Chengdu (China); Zhao, Beijun [Department of Materials Science, Sichuan University, Chengdu (China); Yang, Dingyu; Wangyang, Peihua; Zhu, Xinghua [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu (China)

    2017-02-15

    A promising flexible X-ray detector based on inorganic semiconductor PbI{sub 2} crystal is reported. The sliced crystals mechanically cleaved from an as-grown PbI{sub 2} crystal act as the absorber directly converting the impinging X-ray photons to electron hole pairs. Due to the ductile feature of the PbI{sub 2} crystal, the detector can be operated under a highly curved state with the strain on the top surface up to 1.03% and still maintaining effective detection performance. The stable photocurrent and fast response were obtained with the detector repeated bending to a strain of 1.03% for 100 cycles. This work presents an approach for developing efficient and cost-effective PbI{sub 2}-based flexible X-ray detector. Photocurrent responses of the flexible PbI{sub 2} X-ray detector with the strain on the top surface up to 1.03% proposed in this work with the cross sectional structure and curved detector photograph as insets. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Characteristics of X-ray photons in tilted incident laser-produced plasma

    International Nuclear Information System (INIS)

    Wang Ruirong; Chen Weimin; Xie Dongzhu

    2008-01-01

    Characteristics of X-ray and spout direction of heat plasma flow were studied on Shenguang-II laser facility. Using of pinhole X-ray camera, X-ray photons from the plasma of aluminum (Al) irradiated by 1.053 μm laser, was measured and analysed. It is observed that the spatial distribution of X-ray photons in Al plasma for tilted irradiation is symmetic at the center of the target. The spout direction of heat plasma flow is inferred by the distribution contour of X-ray photons. the experimental results show that the spout direction of heat plasma flow is normal to target plane and the output intensity of X-ray photons does not increase significantly for tilted laser incidence. Uniformity of laser energy deposition is improved by superposing tilted incident and laser perpendicularly incident laser. At the same time, it is found that the conversion efficiency from the tilted incident laser energy to X-ray photons of laser-produced plasma is decreased. (authors)

  16. Nuclear-Recoil Energy Scale in CDMS II Silicon Dark-Matter Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Agnese, R.; et al.

    2018-03-07

    The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

  17. Improved fission neutron energy discrimination with {sup 4}He detectors through pulse filtering

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Ting, E-mail: ting.zhu@ufl.edu [University of Florida, Gainesville, FL (United States); Liang, Yinong; Rolison, Lucas; Barker, Cathleen; Lewis, Jason; Gokhale, Sasmit [University of Florida, Gainesville, FL (United States); Chandra, Rico [Arktis Radiation Detectors Ltd., Räffelstrasse 11, Zürich (Switzerland); Kiff, Scott [Sandia National Laboratories, CA (United States); Chung, Heejun [Korean Institute for Nuclear Nonproliferation and Control, 1534 Yuseong-daero, Yuseong-gu, Daejeon (Korea, Republic of); Ray, Heather; Baciak, James E.; Enqvist, Andreas; Jordan, Kelly A. [University of Florida, Gainesville, FL (United States)

    2017-03-11

    This paper presents experimental and computational techniques implemented for {sup 4}He gas scintillation detectors for induced fission neutron detection. Fission neutrons are produced when natural uranium samples are actively interrogated by 2.45 MeV deuterium-deuterium fusion reaction neutrons. Fission neutrons of energies greater than 2.45 MeV can be distinguished by their different scintillation pulse height spectra since {sup 4}He detectors retain incident fast neutron energy information. To enable the preferential detection of fast neutrons up to 10 MeV and suppress low-energy event counts, the detector photomultiplier gain is lowered and trigger threshold is increased. Pile-up and other unreliable events due to the interrogating neutron flux and background radiation are filtered out prior to the evaluation of pulse height spectra. With these problem-specific calibrations and data processing, the {sup 4}He detector's accuracy at discriminating fission neutrons up to 10 MeV is improved and verified with {sup 252}Cf spontaneous fission neutrons. Given the {sup 4}He detector's ability to differentiate fast neutron sources, this proof-of-concept active-interrogation measurement demonstrates the potential of special nuclear materials detection using a {sup 4}He fast neutron detection system.

  18. Signal and noise analysis in TRION-Time-Resolved Integrative Optical Fast Neutron detector

    International Nuclear Information System (INIS)

    Vartsky, D; Feldman, G; Mor, I; Goldberg, M B; Bar, D; Dangendorf, V

    2009-01-01

    TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector. In contrast to event-counting detectors where the signal-to-noise ratio is dependent only on the number of detected events (quantum noise), in an energy-integrating detector additional factors, such as the fluctuations in imparted energy, number of photoelectrons, system gain and other factors will contribute to the noise. The excess noise factor (over the quantum noise) due to these processes was 4.3, 2.7, 2.1, 1.9 and 1.9 for incident neutron energies of 2, 4, 7.5, 10 and 14 MeV, respectively. It is shown that, even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted proton energy and the resulting scintillation light distributions.

  19. Development of an underwater Cherenkov detector to reveal sources of technogenic radionuclides

    International Nuclear Information System (INIS)

    Chernyaev, A.M.; Gaponov, I.A.; Lapushkina, L.V.

    1999-01-01

    The major difference of the Cherenkov underwater detector from a scintillation detector is that its operation does not require a primary transducer (scintillator). Detected particle energy conversion into a light flash occurs directly in sea water (radiator) due to the Cherenkov effect. Consequently, photoreceiver of the underwater Cherenkov detector registers light from radiator of actually infinite volume. The circumstance is of principle importance, as it permits attaining the utmost sensitivity in case of the minimal overall dimensions and weight of detecting equipment

  20. Thermal self-focusing at oblique incidence

    International Nuclear Information System (INIS)

    Craxton, R.S.; McCrory, R.L.

    1984-03-01

    Thermal self-focusing at oblique incidence has been investigated in two-dimensional line-focus geometry using the Eulerian hydrodynamics simulation code SAGE. The laser beam interacts with a long-scale-length preformed plasma with an expontial density profiele. Questions to be addressed include: (1) What happens when a self-focusing channel reaches the turning point of the incident rays, and (2) Does the unabsorbed light return in the specular direction or back along the channel. A comparison is also made between thermal self-focusing at normal incidence in cylindrical and line-focus geometries: in cylindrical geometry the self-focusing mechanism is enhanced by the relative ease with which plasma may be expelled from a small cylindrical channel

  1. 3D computation of the shape of etched tracks in CR-39 for oblique particle incidence and comparison with experimental results

    International Nuclear Information System (INIS)

    Doerschel, B.; Hermsdorf, D.; Reichelt, U.; Starke, S.; Wang, Y.

    2003-01-01

    Computation of the shape of etch pits needs to know the varying track etch rate along the particle trajectories. Experiments with alpha particles and 7 Li ions entering CR-39 detectors under different angles showed that this function is not affected by the inclination of the particle trajectory with respect to the normal on the detector surface. Track formation for oblique particle incidence can, therefore, be simulated using the track etch rates determined for perpendicular incidence. 3D computation of the track shape was performed applying a model recently described in literature. A special program has been written for computing the x,y,z coordinates of points on the etch pit walls. In addition, the etch pit profiles in sagittal sections as well as the contours of the etch pit openings on the detector surface have been determined experimentally. Computed and experimental results were in good agreement confirming the applicability of the 3D computational model in combination with the functions for the depth-dependent track etch rates determined experimentally

  2. Towards direction dependent fluxes with AMS-02

    Energy Technology Data Exchange (ETDEWEB)

    Zeissler, Stefan; Andeen, Karen; Boer, Wim de; Gebauer, Iris; Merx, Carmen; Nikonov, Nikolay; Vagelli, Valerio [Karlsruher Institut fuer Technologie KIT (Germany)

    2015-07-01

    The Alpha Magnetic Spectrometer (AMS-02) is a state-of-the-art particle physics detector designed to operate as an external module on the International Space Station (ISS). In the unique space environment cosmic particles can be measured with high precision over an energy range from GeV up to TeV. In 2014 electron and positron flux measurements where published which indicate an additional source of positrons among the various cosmic particles. The arrival directions of energetic positrons and electrons convey fundamental information on their origin. We evaluate the AMS-02 detector acceptance for each incoming particle direction and show preliminary results of a direction dependent measurement of the AMS-02 lepton flux.

  3. Monitoring of absolute mirror alignment at COMPASS RICH-1 detector

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, M. [INFN, Sezione di Torino and University of East Piemonte, Alessandria (Italy); INFN, Sezione di Trieste and University of Bari, Bari (Italy); Birsa, R. [INFN, Sezione di Trieste, Trieste (Italy); Bradamante, F.; Bressan, A. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Chiosso, M. [INFN, Sezione di Torino and University of Torino, Torino (Italy); Ciliberti, P. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Dalla Torre, S. [INFN, Sezione di Trieste, Trieste (Italy); Denisov, O. [INFN, Sezione di Torino, Torino (Italy); Duic, V. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Ferrero, A. [INFN, Sezione di Torino and University of Torino, Torino (Italy); Finger, M.; Finger, M. [Charles University, Prague (Czech Republic); JINR, Dubna (Russian Federation); Gayde, J.Ch. [CERN, European Organization for Nuclear Research, Geneva (Switzerland); Giorgi, M. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Gobbo, B.; Levorato, S. [INFN, Sezione di Trieste, Trieste (Italy); Maggiora, A. [INFN, Sezione di Torino, Torino (Italy); Martin, A. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Menon, G. [INFN, Sezione di Trieste, Trieste (Italy); Panzieri, D. [INFN, Sezione di Torino and University of East Piemonte, Alessandria (Italy); and others

    2014-12-01

    The gaseous COMPASS RICH-1 detector uses two spherical mirror surfaces, segmented into 116 individual mirrors, to focus the Cherenkov photons onto the detector plane. Any mirror misalignment directly affects the detector resolution. The on-line Continuous Line Alignment and Monitoring (CLAM) photogrammetry-based method has been implemented to measure the alignment of individual mirrors which can be characterized by the center of curvature. The mirror wall reflects a regular grid of retroreflective strips placed inside the detector vessel. Then, the position of each mirror is determined from the image of the grid reflection. The images are collected by four cameras. Any small mirror misalignment results in changes of the grid lines’ positions in the image. The accuracy limits of the CLAM method were checked by laser interferometry and are below 0.1 mrad.

  4. Detection of secondary electrons with pixelated hybrid semiconductor detectors; Sekundaerelektronennachweis mit pixelierten hybriden Halbleiterdetektoren

    Energy Technology Data Exchange (ETDEWEB)

    Gebert, Ulrike Sonja

    2011-09-14

    Within the scope of this thesis, secondary electrons were detected with a pixelated semiconductor detector named Timepix. The Timepix detector consists of electronics and a sensor made from a semiconductor material. The connection of sensor and electronics is done for each pixel individually using bump bonds. Electrons with energies above 3 keV can be detected with the sensor. One electron produces a certain amount of electron-hole pairs according to its energy. The charge then drifts along an electric field to the pixel electronics, where it induces an electric signal. Even without a sensor it is possible to detect an electric signal from approximately 1000 electrons directly in the pixel electronics. Two different detector systems to detect secondary electrons using the Timepix detector were investigated during this thesis. First of all, a hybrid photon detector (HPD) was used to detect single photoelectrons. The HPD consists of a vacuum vessel with an entrance window and a cesium iodine photocathode at the inner surface of the window. Photoelectrons are released from the photocathode by incident light and are accelerated in an electric field towards the Timepix detector, where the point of interaction and the arrival time of the electron is determined. With a proximity focusing setup, a time resolution of 12 ns (with an acceleration voltage of 20 kV between photocathode and Timepix detector) was obtained. The HPD examined in this thesis showed a strong dependence of the dark rate form the acceleration voltage and the pressure in the vacuum vessel. At a pressure of few 10{sup -5} mbar and an acceleration voltage of 20 kV, the dark rate was about 800 Hz per mm{sup 2} area of the read out photocathode. One possibility to reduce the dark rate is to identify ion feedback events. With a slightly modified setup it was possible to reduce the dark rate to 0.5 Hz/mm{sup 2}. To achieve this, a new photocathode was mounted in a shorter distance to the detector. The

  5. Compton recoil electron tracking with silicon strip detectors

    International Nuclear Information System (INIS)

    O'Neill, T.J.; Ait-Ouamer, F.; Schwartz, I.; Tumer, O.T.; White, R.S.; Zych, A.D.

    1992-01-01

    The application of silicon strip detectors to Compton gamma ray astronomy telescopes is described in this paper. The Silicon Compton Recoil Telescope (SCRT) tracks Compton recoil electrons in silicon strip converters to provide a unique direction for Compton scattered gamma rays above 1 MeV. With strip detectors of modest positional and energy resolutions of 1 mm FWHM and 3% at 662 keV, respectively, 'true imaging' can be achieved to provide an order of magnitude improvement in sensitivity to 1.6 x 10 - 6 γ/cm 2 -s at 2 MeV. The results of extensive Monte Carlo calculations of recoil electrons traversing multiple layers of 200 micron silicon wafers are presented. Multiple Coulomb scattering of the recoil electron in the silicon wafer of the Compton interaction and the next adjacent wafer is the basic limitation to determining the electron's initial direction

  6. Mobility and powering of large detectors. Moving large detectors

    International Nuclear Information System (INIS)

    Thompson, J.

    1977-01-01

    The possibility is considered of moving large lepton detectors at ISABELLE for readying new experiments, detector modifications, and detector repair. A large annex (approximately 25 m x 25 m) would be built adjacent to the Lepton Hall separated from the Lepton Hall by a wall of concrete 11 m high x 12 m wide (for clearance of the detector) and approximately 3 m thick (for radiation shielding). A large pad would support the detector, the door, the cryogenic support system and the counting house. In removing the detector from the beam hall, one would push the pad into the annex, add a dummy beam pipe, bake out the beam pipe, and restack and position the wall on a small pad at the door. The beam could then operate again while experimenters could work on the large detector in the annex. A consideration and rough price estimate of various questions and proposed solutions are given

  7. Extended incident-angle dependence formula of sputter yield

    International Nuclear Information System (INIS)

    Ono, T.; Shibata, K.; Muramoto, T.; Kenmotsu, T.; Li Z.; Kawamura, T.

    2006-06-01

    We extend a new semi-empirical formula for incident-angle dependence of normalized sputter yield that includes the contribution to sputter yield from the direct knock-out process that was not considered in the previously proposed one. Three parameters included in the new one are estimated for data calculated with ACAT code for D + ions incident obliquely on C, Fe and W materials in incident-energy regions from several tens of eV to 10 keV. Then, the parameters are expressed with functions of incident energy. The formula with the functions derived well reproduces that using the ACAT data in the whole energy range. (author)

  8. Active volume studies with depleted and enriched BEGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sturm, Katharina von [Eberhard Karls Universitaet Tuebingen (Germany); Universita degli Studi di Padova, Padua (Italy); Collaboration: GERDA-Collaboration

    2013-07-01

    The Gerda experiment is currently taking data for the search of the 0νββ decay in {sup 76}Ge. In 2013, 30 newly manufactured Broad Energy Germanium (BEGe) diodes will be deployed which will double the active mass within Gerda. These detectors were fabricated from high-purity germanium enriched in {sup 76}Ge and tested in the HADES underground laboratory, owned by SCK.CEN, in Mol, Belgium. As the BEGes are source and detector at the same time, one crucial parameter is their active volume which directly enters into the evaluation of the half-life. This talk illustrates the dead layer and active volume determination of prototype detectors from depleted germanium as well as the newly produced detectors from enriched material, using gamma spectroscopy methods and comparing experimental results to Monte-Carlo simulations. Recent measurements and their results are presented, and systematic effects are discussed.

  9. Charge Collection Efficiency Simulations of Irradiated Silicon Strip Detectors

    CERN Document Server

    Peltola, T.

    2014-01-01

    During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense radiation environment than the present system was designed for. Thus, to upgrade the tracker to required performance level, comprehensive measurements and simulations studies have already been carried out. Essential information of the performance of an irradiated silicon detector is obtained by monitoring its charge collection efficiency (CCE). From the evolution of CCE with fluence, it is possible to directly observe the effect of the radiation induced defects to the ability of the detector to collect charge carriers generated by traversing minimum ionizing particles (mip). In this paper the numerically simulated CCE and CCE loss between the strips of irradiated silicon strip detectors are presented. The simulations based on Synopsys Sentaurus TCAD framework were performed ...

  10. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    Science.gov (United States)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  11. Development of a 3D CZT detector prototype for Laue Lens telescope

    DEFF Research Database (Denmark)

    Caroli, Ezio; Auricchio, Natalia; Del Sordo, Stefano

    2010-01-01

    We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (~19×8 mm2 area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode...

  12. The ALEPH Detector (Apparatus for LEp PHysics)

    CERN Multimedia

    2002-01-01

    ALEPH is a 4$\\pi$ detector designed to give as much detailed information as possible about the complex events produced in high energy $\\mathrm{e}^+\\mathrm{e}^-$ collisions. A superconducting coil 5 metres in diameter and 6 metres long produces a 1.5 Tesla field in the beam direction. Particle detection is accomplished in layers, with each layer performing a particular function.\\\\ \\\\A high resolution vertex detector layers of silicon with double-sided readout provides $r$, $\\phi$ and $z$ coordinates and identifies decay vertices of tau leptons, charm and beauty hadrons. \\\\ \\\\The Inner Tracking Chamber (ITC) is a cylindrical drift chamber with eight axial layers. It gives a high spatial resolution and good track separation, and is also an essential part of the trigger system.\\\\ \\\\The Time Projection Chamber (TPC), 3.6 metres in diameter and 4.4 metres long, measures track momenta and directions. It also provides up to 338 energy loss measurements per track for particle identification. The momentum resolution of...

  13. NAIR: handbook on the national arrangements for incidents involving radioactivity

    International Nuclear Information System (INIS)

    1987-01-01

    A revised handbook on the national arrangements for incidents involving radioactivity (NAIR) has been published. Following brief introductory sections on the administrative aspects and operational aspects, the main part of the handbook is devoted to operational and call-out lists including an index of police forces served by NAIR, an index of establishments providing assistance under NAIR, sources of stage 1 and stage 2 assistance for each police constabulary, hospitals prepared to accept contaminated casualties and to assist with decontamination of personnel, and hospitals prepared to advise on the treatment and admission of casualties exposed to large doses of radiation. Technical appendices are also given on radiological protection in NAIR incidents, instruments and equipment, radionuclide data and a guide to suitable detectors, package and source identification and disposal of radioactive materials involved in NAIR accidents. (U.K.)

  14. Light scattering by microstructures in plastic nuclear track detector plane surfaces

    International Nuclear Information System (INIS)

    Wipasuramonton, O.

    1985-01-01

    The angular distributions of light elastically scattered by finite dielectric conical and cylindrical microstructures in plastic nuclear track detector plane surfaces have been measured. These microstructures are the chemically etched tracks of various nuclei, viz., protons, neutrons, 3 He, alphas, and 56 Fe. The base diameters of the structures are larger than twice the wavelength of the incident light. The results show the dependence of the scattering patterns on shape, size, orientation, and refractive index of the structures as well as the polarization of the incident light. It is also observed that in the single and independent scattering regime, the intensity at the intermediate angular region exhibits linear proportionality to the number of the microstructures per unit area. 84 refs., 96 figs., 4 tabs

  15. Measurement of track opening contours of oblique incident 4He and 7Li-ions in CR-39: Relevance for calculation of track formation parameters

    International Nuclear Information System (INIS)

    Hermsdorf, D.; Reichelt, U.

    2010-01-01

    Solid State Nuclear Track Detectors (SSNTD) irradiated in realistic radiation fields exhibits after chemical etching very complex track images resulting from different species of particles and their energy spectra and randomly distributed angles of incidence or emission. Reading out such an etched detector surface with a light microscope, quite different track opening contours are observed. Beside the number of tracks, typically their major and minor axes are measured. In this work following problems arising from such experimental situations will be investigated: ·the measurement of track contour parameters for oblique incident 4 He and 7 Li-ions of different energies and angles in CR-39 detectors ·the theoretical description of the angular variation of both axes. ·the possibility to extract physical and spectroscopic information from major and minor track axes. This analysis is based on an intensive experimental program and the comprehensive study of theoretical models available for description of track revealing processes in CR-39.

  16. Luminosity Measurement at ATLAS Development, Construction and Test of Scintillating Fibre Prototype Detectors

    CERN Document Server

    Ask, S; Braem, André; Cheiklali, C; Efthymiopoulos, I; Fournier, D; de La Taille, C; Di Girolamo, B; Grafström, P; Joram, C; Haguenauer, Maurice; Hedberg, V; Lavigne, B; Maio, A; Mapelli, A; Mjörnmark, U; Puzo, P; Rijssenbeek, M; Santos, J; Saraiva, J G; Stenzel, H; Thioye, M; Valladolid, E; Vorobel, V

    2006-01-01

    We are reporting about a scintillating fibre tracking detector which is proposed for the precise determination of the absolute luminosity of the CERN LHC at interaction point 1 where the ATLAS experiment is located. The detector needs to track protons elastically scattered under $\\mu$rad angles in direct vicinity to the LHC beam. It is based on square shaped scintillating plastic fibres read out by multi-anode photomultiplier tubes and is housed in Roman Pots. We describe the design and construction of prototype detectors and the results of a beam test experiment at DESY. The excellent detector performance established in this test validates the detector design and supports the feasibility of the proposed challenging method of luminosity measurement.

  17. 2011 ATLAS Detector Performance - ID and Forward detectors

    CERN Document Server

    Davies‎, E; The ATLAS collaboration; Abdel Khalek, S

    2012-01-01

    This poster describes the performance of 2 parts of ATLAS: - The Inner Detector which consists of 3 subdetectors: the Pixel detector, the SemiConductor Tracker (or SCT) and the Transition Radiation Tracker (or TRT). Here, we report on Pixel detector and SCT performance over 2011. - ALFA detector which will determine the absolute luminosity of the CERN LHC at the ATLAS Interaction Point (IP), and the total proton-proton cross section, by tracking elastically scattered protons at very small angles in the limit of the Coulomb Nuclear interference region.

  18. Infrared detectors

    CERN Document Server

    Rogalski, Antonio

    2010-01-01

    This second edition is fully revised and reorganized, with new chapters concerning third generation and quantum dot detectors, THz detectors, cantilever and antenna coupled detectors, and information on radiometry and IR optics materials. Part IV concerning focal plane arrays is significantly expanded. This book, resembling an encyclopedia of IR detectors, is well illustrated and contains many original references … a really comprehensive book.-F. Sizov, Institute of Semiconductor Physics, National Academy of Sciences, Kiev, Ukraine

  19. Development of SiC Neutron Detector Assembly to Measure the Neutron Flux of the Reactor Core

    Energy Technology Data Exchange (ETDEWEB)

    Park, Se Hwan; Park, June Sic; Shin, Hee Sung; Kim, Ho Dong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Yong Kyun [Hanyang University, Seoul (Korea, Republic of)

    2012-05-15

    At present, the conventional detector to measure the neutron at harsh environment is a Self Powered Neutron Detector (SPND). Rhodium(Rh)-103 is in the SPND. When neutron is incident on the Rhodium, the neutron capture reaction occurs, and the Rh-103 is converted to Rh-104. The Rh-104 is decayed to Pd-104 by {beta}-decay, and electrons are generated as the decay products. Because of the half life of Rh-104, approximately 5 minutes are required for the SPND output to reach the equilibrium condition. Therefore the on-line monitoring of the nuclear reactor state is limited if the neutron flux in the reactor core is monitored with the SPND. Silicon carbide (SiC) has the possibility to be developed as neutron detector at harsh environment, because the SiC can be operative at high temperature and high neutron flux conditions. Previously, the basic operation properties of the SiC detector were studied. Also, the radiation response of the SiC detector was studied at high neutron and gamma dose rate. The measurement results for an ex-core neutron flux monitor or a neutron flux monitor of the spent fuel were published. The SiC detector was also developed as neutron detector to measure the fissile material with active interrogation method. However, the studies about the development of SiC detector are still limited. In the present work, the radiation damage effect of the SiC detector was studied. The detector structure was determined based on the study, and a neutron detector assembly was made with the SiC detectors. The neutron and gamma-ray response of the detector assembly is presented in this paper. The detector assembly was positioned in the HANARO research reactor core, the performance test was done. The preliminary results are also included in this paper

  20. Multi-detector and systematic imaging system designed and developed within the New AGLAE project

    International Nuclear Information System (INIS)

    Pichon, L.; Pacheco, C.; Moignard, B.; Lemasson, Q.; Guillou, T.; Walter, Ph

    2013-01-01

    Full text: The New AGLAE project aims to establish a world-class facility for non invasive analysis of Cultural Heritage materials. One of the objectives of the New AGLAE project is to increase the x-ray measurement detection, enabling to reduce the beam intensity thus the interaction with sensitive artworks by a ten. Multidisciplinary, the New AGLAE project will provide an exceptional and multipurpose beam line with a performance in spatial resolution, beam stability and a capability of multi-particle detection much higher than for the previous facility. The New AGLAE will give fundamental elements for the understanding of the structure of materials, their composition, properties, and change over time. One of the objectives of this project is to design and set up a new data acquisition system. To reach that purpose, the surface and the number of PIXE detectors have been increased. Indeed, a 10 mm 2 and a 30 mm 3 Si(Li) detectors respectively dedicated to low and high energy measurements, were replaced by a cluster of five 50 mm 2 S.D.D. detectors. If this multi detector enables to decrease the intensity of the incident beam by one order of magnitude, involving less irradiation during the analysis, it can also provide large and/or fast maps. So as to digital the preamp pulses obtained from the detectors, a custom Digital X-ray Processor provides both digital data and control signals compatible to a multiparameter multichannel system. This multiparameter system saves each event from x-ray, gamma and particle detectors and simultaneously the X, Y positions of the beam on the sample as a list file. Furthermore, to draw several-cm-sized maps with a 20/40μm resolution, the scanning of the area originally combines a fast vertical magnetic deflection of the beam and a mechanical movement of the target. To process the data, several homemade software have been developed or updated so as to rebuild any matrix of spectra, to re-bin maps, to process a series of single spectra