WorldWideScience

Sample records for incidence angle modifiers

  1. A correlation model to compute the incidence angle modifier and to estimate its effect on collectible solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Armenta-Deu, C. (Universidad Complutense de Madrid (ES). Facultad Fisicas); Lukac, B. (University of T. and C. Zilina (CS))

    1991-01-01

    The radiation transmittance and absorptance of materials vary according to the angle of incidence of the incoming solar radiation. Therefore, the efficiency of most solar converters (thermal or photovoltaic) is a function of the sun's position through the angle of incidence. This problem may be taken account of by the Incidence Angle Modifier, which is considered in this paper. An analytic expression for the incidence angle modifier, based on meteorological data or on geographic and geometric parameters, has been developed; this expression includes the effect of beam and diffuse radiation as well as the global influence. A comparison between measured data and these computed from our model has given a very good correlation, the results being within {+-}3% for horizontal and titled planes, and within {+-}7% for vertical surfaces, on average. The method also computes the collectible solar energy within a 5% error for thresholds up to 300Wm{sup -2}. The method has been validated for more than 30 locations in south and west Europe. (author).

  2. Tiny incident light angle sensor

    Science.gov (United States)

    Mitrenga, D.; Schädel, M.; Winzer, A. T.; Völlmeke, S.; Preuß, K. D.; Freitag, J.; Brodersen, O.

    2017-05-01

    A novel device for detecting the intensity and the angles of incoming light is presented. The silicon chip with 1 mm edge length comprises a segmented photo diode with four active areas within the inclined surfaces of a deep etched cavity. Simple signal difference analysis of these signals allow for accurate azimuth and inclination measurement in the range of 0 to 360° and 0 to 55°, respectively. Using an artificial neural network (ANN) calibration strategy the operation range of inclination can be increased up to 85° with typical angle errors below 2°. In this report we present details on design, fabrication, signal analysis and calibration strategies.

  3. Solar cell angle of incidence corrections

    Science.gov (United States)

    Burger, Dale R.; Mueller, Robert L.

    1995-01-01

    Literature on solar array angle of incidence corrections was found to be sparse and contained no tabular data for support. This lack along with recent data on 27 GaAs/Ge 4 cm by 4 cm cells initiated the analysis presented in this paper. The literature cites seven possible contributors to angle of incidence effects: cosine, optical front surface, edge, shadowing, UV degradation, particulate soiling, and background color. Only the first three are covered in this paper due to lack of sufficient data. The cosine correction is commonly used but is not sufficient when the incident angle is large. Fresnel reflection calculations require knowledge of the index of refraction of the coverglass front surface. The absolute index of refraction for the coverglass front surface was not known nor was it measured due to lack of funds. However, a value for the index of refraction was obtained by examining how the prediction errors varied with different assumed indices and selecting the best fit to the set of measured values. Corrections using front surface Fresnel reflection along with the cosine correction give very good predictive results when compared to measured data, except there is a definite trend away from predicted values at the larger incident angles. This trend could be related to edge effects and is illustrated by a use of a box plot of the errors and by plotting the deviation of the mean against incidence angle. The trend is for larger deviations at larger incidence angles and there may be a fourth order effect involved in the trend. A chi-squared test was used to determine if the measurement errors were normally distributed. At 10 degrees the chi-squared test failed, probably due to the very small numbers involved or a bias from the measurement procedure. All other angles showed a good fit to the normal distribution with increasing goodness-of-fit as the angles increased which reinforces the very small numbers hypothesis. The contributed data only went to 65 degrees

  4. Modified angle's classification for primary dentition

    Directory of Open Access Journals (Sweden)

    Kaushik Narendra Chandranee

    2017-01-01

    Full Text Available Aim: This study aims to propose a modification of Angle's classification for primary dentition and to assess its applicability in children from Central India, Nagpur. Methods: Modification in Angle's classification has been proposed for application in primary dentition. Small roman numbers i/ii/iii are used for primary dentition notation to represent Angle's Class I/II/III molar relationships as in permanent dentition, respectively. To assess applicability of modified Angle's classification a cross-sectional preschool 2000 children population from central India; 3–6 years of age residing in Nagpur metropolitan city of Maharashtra state were selected randomly as per the inclusion and exclusion criteria. Results: Majority 93.35% children were found to have bilateral Class i followed by 2.5% bilateral Class ii and 0.2% bilateral half cusp Class iii molar relationships as per the modified Angle's classification for primary dentition. About 3.75% children had various combinations of Class ii relationships and 0.2% children were having Class iii subdivision relationship. Conclusions: Modification of Angle's classification for application in primary dentition has been proposed. A cross-sectional investigation using new classification revealed various 6.25% Class ii and 0.4% Class iii molar relationships cases in preschool children population in a metropolitan city of Nagpur. Application of the modified Angle's classification to other population groups is warranted to validate its routine application in clinical pediatric dentistry.

  5. Investigation of Polarimetric SAR Data Acquired at Multiple Incidence Angles

    DEFF Research Database (Denmark)

    Svendsen, Morten Thougaard; Skriver, Henning; Thomsen, A.

    1998-01-01

    The dependence of different polarimetric parameters on the incidence angles in the range of 30° to 60° is investigated for a number of different crops using airborne SAR data. The purpose of the investigation is to determine the effect of the variation of incidence angle within a SAR image when...

  6. Discriminating electromagnetic radiation based on angle of incidence

    Science.gov (United States)

    Hamam, Rafif E.; Bermel, Peter; Celanovic, Ivan; Soljacic, Marin; Yeng, Adrian Y. X.; Ghebrebrhan, Michael; Joannopoulos, John D.

    2015-06-16

    The present invention provides systems, articles, and methods for discriminating electromagnetic radiation based upon the angle of incidence of the electromagnetic radiation. In some cases, the materials and systems described herein can be capable of inhibiting reflection of electromagnetic radiation (e.g., the materials and systems can be capable of transmitting and/or absorbing electromagnetic radiation) within a given range of angles of incidence at a first incident surface, while substantially reflecting electromagnetic radiation outside the range of angles of incidence at a second incident surface (which can be the same as or different from the first incident surface). A photonic material comprising a plurality of periodically occurring separate domains can be used, in some cases, to selectively transmit and/or selectively absorb one portion of incoming electromagnetic radiation while reflecting another portion of incoming electromagnetic radiation, based upon the angle of incidence. In some embodiments, one domain of the photonic material can include an isotropic dielectric function, while another domain of the photonic material can include an anisotropic dielectric function. In some instances, one domain of the photonic material can include an isotropic magnetic permeability, while another domain of the photonic material can include an anisotropic magnetic permeability. In some embodiments, non-photonic materials (e.g., materials with relatively large scale features) can be used to selectively absorb incoming electromagnetic radiation based on angle of incidence.

  7. Comparison of various methods for estimating wave incident angles ...

    African Journals Online (AJOL)

    Five different methods were examined for their suitability in estimating the inshore wave incident angles on a nearshore zone with a complex topography. Visual observation provided preliminary estimates. Two frequency independent methods and one frequency dependent method based on current meter measurements ...

  8. Incident angle dependence of reactions between graphene and hydrogen atom by molecular dynamics simulation

    International Nuclear Information System (INIS)

    Saito, Seiki; Nakamura, Hiroaki; Ito, Atsushi

    2010-01-01

    Incident angle dependence of reactions between graphene and hydrogen atoms are obtained qualitatively by classical molecular dynamics simulation under the NVE condition with modified Brenner reactive empirical bond order (REBO) potential. Chemical reaction depends on two parameters, i.e., polar angle θ and azimuthal angle φ of the incident hydrogen. From the simulation results, it is found that the reaction rates strongly depend on polar angle θ. Reflection rate becomes larger with increasing θ, and the θ dependence of adsorption rate is also found. The θ dependence is caused by three dimensional structure of the small potential barrier which covers adsorption sites. φ dependence of penetration rate is also found for large θ. (author)

  9. Dependance of sputtering yield on incident angle for ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Tanizaki, Hironori; Ooba, Hikaru; Masuhara, Kenichi

    1987-07-01

    The relationship between sputtering yeild (S/sub theta/) and the incident angle (theta) of an ion beam to some metals such as Fe, Ni, Zn and SUS304, was studied by Ion Micro Analyzer (IMA). It was confirmed that S/sub theta/ varied as a function of (costheta)/sup -f/. The value of f was differed with each sample, and ranged from 1.0 to 1.5 in this study. As theta increased, the surface roughness of the sputtered samples became greater, and the depth resolution of the depth profile became worse. It is necessary to pay attention to depth resolution, when various data concerning different incident angles are compared.

  10. Asymmetric-cut variable-incident-angle monochromator.

    Science.gov (United States)

    Smither, R K; Graber, T J; Fernandez, P B; Mills, D M

    2012-03-01

    A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18° asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage (Φ) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation (Ψ) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation (Θ) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

  11. Aerodynamic Investigation of Incidence Angle Effects in a Large Scale Transonic Turbine Cascade

    Science.gov (United States)

    McVetta, Ashlie B.; Giel, Paul W.; Welch, Gerard E.

    2013-01-01

    Aerodynamic measurements showing the effects of large incidence angle variations on an HPT turbine blade set are presented. Measurements were made in NASA's Transonic Turbine Blade Cascade Facility which has been used in previous studies to acquire detailed aerodynamic and heat transfer measurements for CFD code validation. The current study supports the development of variable-speed power turbine (VSPT) speed-change technology for the NASA Large Civil Tilt Rotor (LCTR) vehicle. In order to maintain acceptable main rotor propulsive efficiency, the VSPT operates over a nearly 50 percent speed range from takeoff to altitude cruise. This results in 50deg or more variations in VSPT blade incidence angles. The cascade facility has the ability to operate over a wide range of Reynolds numbers and Mach numbers, but had to be modified in order to accommodate the negative incidence angle variation required by the LCTR VSPT operation. Using existing blade geometry with previously acquired aerodynamic data, the tunnel was re-baselined and the new incidence angle range was exercised. Midspan exit total pressure and flow angle measurements were obtained at seven inlet flow angles. For each inlet angle, data were obtained at five flow conditions with inlet Reynolds numbers varying from 6.83×10(exp 5) to 0.85×10(exp 5) and two isentropic exit Mach numbers of 0.74 and 0.34. The midspan flowfield measurements were acquired using a three-hole pneumatic probe located in a survey plane 8.6 percent axial chord downstream of the blade trailing edge plane and covering three blade passages. Blade and endwall static pressure distributions were also acquired for each flow condition.

  12. Aerodynamic Investigation of Incidence Angle Effects in a Large Scale Transonic Turbine Cascade. Revision 1

    Science.gov (United States)

    McVetta, Ashlie B.; Giel, Paul W.; Welch, Gerard E.

    2014-01-01

    Aerodynamic measurements showing the effects of large incidence angle variations on an HPT turbine blade set are presented. Measurements were made in NASA's Transonic Turbine Blade Cascade Facility which has been used in previous studies to acquire detailed aerodynamic and heat transfer measurements for CFD code validation. The current study supports the development of variable-speed power turbine (VSPT) speed-change technology for the NASA Large Civil Tilt Rotor (LCTR) vehicle. In order to maintain acceptable main rotor propulsive efficiency, the VSPT operates over a nearly 50 percent speed range from takeoff to altitude cruise. This results in 50 deg or more variations in VSPT blade incidence angles. The cascade facility has the ability to operate over a wide range of Reynolds numbers and Mach numbers, but had to be modified in order to accommodate the negative incidence angle variation required by the LCTR VSPT operation. Using existing blade geometry with previously acquired aerodynamic data, the tunnel was re-baselined and the new incidence angle range was exercised. Midspan exit total pressure and flow angle measurements were obtained at seven inlet flow angles. For each inlet angle, data were obtained at five flow conditions with inlet Reynolds numbers varying from 6.83×10 (exp 5) to 0.85×10(exp 5) and two isentropic exit Mach numbers of 0.74 and 0.34. The midspan flowfield measurements were acquired using a three-hole pneumatic probe located in a survey plane 8.6 percent axial chord downstream of the blade trailing edge plane and covering three blade passages. Blade and endwall static pressure distributions were also acquired for each flow condition.

  13. The modified Cassie’s equation and contact angle hysteresis

    KAUST Repository

    Xu, Xianmin

    2012-08-29

    In this paper, we derive a modified Cassie\\'s equation for wetting on chemically patterned surfaces from a homogenization approach. The derivation reveals that effective contact angle is a local average of the static contact angle along the contact line which describes all possible equilibrium states including the local minimum of the free energy of the system. The usual Cassie\\'s state which corresponds to the global minimum is only a special case. We then discuss the contact angle hysteresis on chemically patterned surfaces. © 2012 Springer-Verlag.

  14. Modified dark room provocative test for primary angle closure.

    Science.gov (United States)

    Li, Dejiao; Wang, Ningli; Wang, Bingsong; Wang, Tao; Jonas, Jost B

    2012-03-01

    To examine the diagnostic value of a modified dark room provocative test (DRPT) in detecting primary closure of the anterior chamber angle. The cross-sectional observational prospective clinical study included suspects of primary angle closure. Using anterior segment optical coherence tomography (AS-OCT), we measured the anterior chamber angle configuration at room light and after 3 minutes of dark adaptation. Gonioscopy and Perkin's applanation tonometry were performed in room light conditions at baseline and after 1.5 hours of dark adaptation. The number of closed angle quadrants assessed on AS-OCT images and upon gonioscopy were recorded. The DRPT was positive, if intraocular pressure increased by ≥8 mm Hg after 1.5 hours of dark adaptation. The study included 76 subjects (76 eyes). Among 32 (42%) eyes with a positive DRPT, the number of eyes with an increased number of closed angle quadrants was significantly higher for the OCT examination at 3 minutes of dark adaptation than for gonioscopy at 1.5 hours of dark adaptation [29 (91%) eyes vs 21 (66%) eyes; P=0.01]. Kappa statistics showed a moderate agreement between increased closed angle quadrants obtained both after 3 minutes of dark adaptation (κ=0.44; Pdark room test (κ=0.45; Pdark room test. A modified DRPT with an anterior chamber angle assessment by OCT at 3 minutes of dark adaptation as compared with a gonioscopic angle assessment after 1.5 hours of dark adaptation had a higher diagnostic precision in predicting primary angle closure.

  15. Uncertainty in multispectral lidar signals caused by incidence angle effects.

    Science.gov (United States)

    Kaasalainen, Sanna; Åkerblom, Markku; Nevalainen, Olli; Hakala, Teemu; Kaasalainen, Mikko

    2018-04-06

    Multispectral terrestrial laser scanning (TLS) is an emerging technology. Several manufacturers already offer commercial dual or three wavelength airborne laser scanners, while multispectral TLS is still carried out mainly with research instruments. Many of these research efforts have focused on the study of vegetation. The aim of this paper is to study the uncertainty of the measurement of spectral indices of vegetation with multispectral lidar. Using two spectral indices as examples, we find that the uncertainty is due to systematic errors caused by the wavelength dependency of laser incidence angle effects. This finding is empirical, and the error cannot be removed by modelling or instrument modification. The discovery and study of these effects has been enabled by hyperspectral and multispectral TLS, and it has become a subject of active research within the past few years. We summarize the most recent studies on multi-wavelength incidence angle effects and present new results on the effect of specular reflection from the leaf surface, and the surface structure, which have been suggested to play a key role. We also discuss the consequences to the measurement of spectral indices with multispectral TLS, and a possible correction scheme using a synthetic laser footprint.

  16. Linear systems formulation of scattering theory for rough surfaces with arbitrary incident and scattering angles.

    Science.gov (United States)

    Krywonos, Andrey; Harvey, James E; Choi, Narak

    2011-06-01

    Scattering effects from microtopographic surface roughness are merely nonparaxial diffraction phenomena resulting from random phase variations in the reflected or transmitted wavefront. Rayleigh-Rice, Beckmann-Kirchhoff. or Harvey-Shack surface scatter theories are commonly used to predict surface scatter effects. Smooth-surface and/or paraxial approximations have severely limited the range of applicability of each of the above theoretical treatments. A recent linear systems formulation of nonparaxial scalar diffraction theory applied to surface scatter phenomena resulted first in an empirically modified Beckmann-Kirchhoff surface scatter model, then a generalized Harvey-Shack theory that produces accurate results for rougher surfaces than the Rayleigh-Rice theory and for larger incident and scattered angles than the classical Beckmann-Kirchhoff and the original Harvey-Shack theories. These new developments simplify the analysis and understanding of nonintuitive scattering behavior from rough surfaces illuminated at arbitrary incident angles.

  17. Incident-angle sensitive neutron detector using scintillating fibers

    International Nuclear Information System (INIS)

    Iguchi, Tetsuo; Kawarabayashi, Jun; Mizuno, Ryoji; Inui, Daisuke; Watanabe, Kenichi; Nishitani, Takeo; Yamauchi, Michinori

    2004-01-01

    Neutron measurement in fusion experimental devices is very important for burning plasma diagnostics and control. In particular, neutron emission profile measurement provides useful information on the profile of ion temperatures and densities as well as the time-dependent neutron yield profile. So far several studies have been made on the neutron emission profile monitor, which are almost based on a large number of neutron threshold detectors or neutron spectrometers combined with a massive multichannel neutron collimator. The detectors can provide line-integrated neutron emissivity along the direction of collimator. Neutron emissivity over a poloidal section of plasma is determined by installing a vertical neutron camera and a horizontal neutron camera. However, one of the most serious problems on this type of system is that the spatial resolution is restricted by the collimator design. The restriction of location to install the massive and heavy collimator system is also a difficult problem for the complicated and tight machine integration. To improve these difficulties, we propose a novel incident-angle sensitive neutron detector using scintillating fibers. In this report, we describe the results on preliminary experiments to confirm the operational principle and basic performance a prototype detector element. (author)

  18. The equivalent incidence angle for porous absorbers backed by a hard surface

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Brunskog, Jonas

    2013-01-01

    experiment using a free-field absorption measurement technique with a source at the equivalent angle. This study investigates the equivalent angle for locally and extendedly reacting porous media mainly by a numerical approach: Numerical minimizations of a cost function that is the difference between...... coefficients by free-field techniques, a broad incidence angle range can be suggested: 20 hi65 for extended reaction and hi65 for locally reacting porous absorbers, if an average difference of 0.05 is allowed.......An equivalent incidence angle is defined as the incidence angle at which the oblique incidence absorption coefficient best approximates the random incidence absorption coefficient. Once the equivalent angle is known, the random incidence absorption coefficient can be estimated by a single...

  19. Influence of laser beam incidence angle on laser lap welding quality of galvanized steels

    Science.gov (United States)

    Mei, Lifang; Yan, Dongbing; Chen, Genyu; Wang, Zhenhui; Chen, Shuixuan

    2017-11-01

    Based on the characteristics of laser welded structural parts of auto bodies, the influence of variation in laser beam incidence angle on the lap welding performance of galvanized auto-body sheets was studied. Lap welding tests were carried out on the galvanized sheets for auto-body application at different laser beam incidence angles by using the optimal welding parameters obtained through orthogonal experiment. The effects of incidence angle variation on seam appearance, cross-sectional shape, joint mechanical properties and microstructure of weldments were analyzed. In addition, the main factors influencing the value of incidence angle were investigated. According to the results, the weld seams had a good appearance as well as a fine, and uniform microstructure when the laser beam incidence angle was smaller than the critical incidence angle, and thus they could withstand great tensile and shear loads. Moreover, all tensile-shear specimens were fractured in the base material zone. When the laser beam incidence angle was larger than the critical incidence angle, defects like shrinkage and collapse tended to emerge, thereby resulting in the deteriorated weldability of specimens. Meanwhile, factors like the type and thickness of sheet, weld width as well as inter-sheet gap all had a certain effect on the value of laser beam incidence angle. When the sheet thickness was small and the weld width was narrow, the laser beam incidence angle could be increased appropriately. At the same time, small changes in the inter-sheet gap could greatly impact the value of incidence angle. When the inter-sheet gap was small, the laser beam incidence angle should not be too large.

  20. Modified small angle magnetization rotation method in multilayer magnetic microwires

    International Nuclear Information System (INIS)

    Torrejon, J.; Badini, G.; Pirota, K.; Vazquez, M.

    2007-01-01

    The small angle magnetization rotation (SAMR) technique is a widely used method to quantify magnetostriction in elongated ultrasoft magnetic materials. In the present work, we introduce significant optimization of the method, particularly simplification of the required equipment, profiting of the very peculiar characteristics of a recently introduced family of multilayer magnetic microwires consisting of a soft magnetic core, insulating intermediate layer and a hard magnetic outer layer. The introduced modified SAMR method is used not only to determine the saturation magnetostriction constant of the soft magnetic nucleus but also the magnetoelastic and magnetostatic coupling. This new method has a great potential in multifunctional sensor applications

  1. The effects of laser beam incident angle and intensity distribution on Fabry-Perot etalon spectrum

    Science.gov (United States)

    Shen, Fahua; Wang, Yingying; Shi, Wenjuan; Chen, Ying; Liu, Mengling; Guo, Wenxin

    2017-11-01

    Fabry-Perot(F-P) etalon has important applications in laser detection, lidar and laser communication systems. In practical applications, the spectrum of the F-P etalon is affected by various factors, such as incident angle, divergence angle, spectral width, intensity distribution of the incident beam, absorption loss, surface defects of the plate and so on. The effects of the incident angle and the beam intensity distribution on F-P etalon spectrum are mainly analyzed. For the first time, taking into account both the beam incident angle and divergence angle, the precise analytical expression of the F-P etalon transmission spectrum is derived. For the Gaussian light intensity distribution, the precise analytical expression of the F-P etalon transmission spectrum is derived. The simulation analysis is carried out and the results are as follows. When the beam divergence angle is not zero, the incident angle increases, on the one hand, the center of the etalon spectrum is moved to the high frequency, and the frequency shift is linear with the square of the incident angle. The slope decreases with the increase of the divergence angle. On the other hand, resulting in peak reduction, spectral line broadening, and with the divergence angle increases, the more obvious the phenomenon. Considering the distribution of Gaussian light intensity, the spectrum of the etalon will be improved with the increase concentration of beam energy. On the one hand, the peak value is increased, the spectral line is narrowed and with the incidence angle increases, the degree of improvement is more obvious. On the one hand, the center of the spectrum moves toward the low frequency, but the larger the incident angle, the smaller the movement amount. The error of frequency discrimination or frequency locking by using the F-P etalon spectrum increases rapidly with the increase of the beam incident angle and beam divergence angle, and the Gaussian light intensity distribution beam can effectively

  2. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    International Nuclear Information System (INIS)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja; Han, Beon Hee

    2012-01-01

    In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is 15 degrees to 20 degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were 15.9 degrees, the twenties were 16.9 degrees, the thirties were 16.6 degrees, the forties were 16.2 degrees, the fifties were 15.9 degrees, and the sixties were 14.5 degrees, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by 2 degrees. When the incidence angle statistically analyzed with measurement of average length of

  3. A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination

    Energy Technology Data Exchange (ETDEWEB)

    Jeung, Seung Woon; Lim, Cheong Hwan; Jung, Hong Ryang; Joo, Yeong Cheol; Park, Mi Ja [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of); Han, Beon Hee [Dept. of Radiological Science, Seonam University, Namwon (Korea, Republic of)

    2012-06-15

    In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is 15 degrees to 20 degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were 15.9 degrees, the twenties were 16.9 degrees, the thirties were 16.6 degrees, the forties were 16.2 degrees, the fifties were 15.9 degrees, and the sixties were 14.5 degrees, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by 2 degrees. When the incidence angle statistically analyzed with measurement of average length

  4. Energy Reflection from Gold Bombarded with keV Protons at Various Angles of Incidence

    DEFF Research Database (Denmark)

    Sørensen, H.

    1976-01-01

    The calorimetric deuterium film method operating at liquid‐helium temperature was used for measuring the energy reflection coefficient γ for 1–10‐keV protons incident on gold at angles of incidence up to 75°. H+2 and H+3 ions were used to obtain the lowest velocities. The growth with angle...

  5. Study on laser welding of austenitic stainless steel by varying incident angle of pulsed laser beam

    Science.gov (United States)

    Kumar, Nikhil; Mukherjee, Manidipto; Bandyopadhyay, Asish

    2017-09-01

    In the present work, AISI 304 stainless steel sheets are laser welded in butt joint configuration using a robotic control 600 W pulsed Nd:YAG laser system. The objective of the work is of twofold. Firstly, the study aims to find out the effect of incident angle on the weld pool geometry, microstructure and tensile property of the welded joints. Secondly, a set of experiments are conducted, according to response surface design, to investigate the effects of process parameters, namely, incident angle of laser beam, laser power and welding speed, on ultimate tensile strength by developing a second order polynomial equation. Study with three different incident angle of laser beam 89.7 deg, 85.5 deg and 83 deg has been presented in this work. It is observed that the weld pool geometry has been significantly altered with the deviation in incident angle. The weld pool shape at the top surface has been altered from semispherical or nearly spherical shape to tear drop shape with decrease in incident angle. Simultaneously, planer, fine columnar dendritic and coarse columnar dendritic structures have been observed at 89.7 deg, 85.5 deg and 83 deg incident angle respectively. Weld metals with 85.5 deg incident angle has higher fraction of carbide and δ-ferrite precipitation in the austenitic matrix compared to other weld conditions. Hence, weld metal of 85.5 deg incident angle achieved higher micro-hardness of ∼280 HV and tensile strength of 579.26 MPa followed by 89.7 deg and 83 deg incident angle welds. Furthermore, the predicted maximum value of ultimate tensile strength of 580.50 MPa has been achieved for 85.95 deg incident angle using the developed equation where other two optimum parameter settings have been obtained as laser power of 455.52 W and welding speed of 4.95 mm/s. This observation has been satisfactorily validated by three confirmatory tests.

  6. All-angle collimation of incident light in μ-near-zero metamaterials.

    Science.gov (United States)

    Fedorov, Vladimir Yu; Nakajima, Takashi

    2013-11-18

    We use the theory of inhomogeneous waves to study the transmission of light in μ-near-zero metamaterials. We find the effect of all-angle collimation of incident light, which means that the vector of energy flow in a wave transmitted to a μ-near-zero metamaterial is perpendicular to the interface for any incident angles if an incident wave is s-polarized. This effect is similar to the all-angle collimation of incident light recently found through a different theoretical framework in ε-near-zero metamaterials for a p-polarized incident wave [S. Feng, Phys. Rev. Lett. 108, 193904 (2012)]. To provide a specific example, we consider the transmission of light in a negative-index metamaterial in the spectral region with a permeability resonance, and show that all-angle collimation indeed takes place at the wavelength for which the real part of permeability is vanishingly small.

  7. Grazing incident small angle neutron scattering. Analysis of self-assembly of softmatters in thin films

    International Nuclear Information System (INIS)

    Yokoyama, Hideaki

    2009-01-01

    Grazing incident small angle scattering has been used for the analysis of surface and thin film structures. X-ray in particular is widely used for such analysis and called grazing incident small angle X-ray scattering (GISAXS). However, a very limited number of studied has been done using grazing incident small angle neutron scattering (GISANS) primarily due to low intensity of neutron beam. The arising JPARC neutron source will enable us to use GISANS to analyze thin film structures of softmatter. This report provides a basic concept of GISAS using an example of the analysis of nanocellular thin films fabricated by block copolymer template with supercritical carbon dioxide (BSTSC). (author)

  8. Effect of the incidence angle of disjunctive displacements on equipment set productivity

    Energy Technology Data Exchange (ETDEWEB)

    Kozel, K.K. (L' vovsko-Volynskaya GREh (USSR))

    1990-04-01

    Deals with the effect of the incidence angle of the dislocation plane on mining equipment productivity in the Chervonograd region of the L'vov-Volynsk coal basin. It was found that of the approximately 210 tectonic dislocations analyzed, 40% had an incidence angle of the dislocation plane of 21-40 degrees. A coefficient of production level has been introduced defined as the ratio of working face advance in disturbed zones to advance in undisturbed zones. Mean working face advance was 49.7 m/month. Variation of the coefficient of production level with the incidence angle of the dislocation plane is discussed and regression equations are given for the coefficient for three shearer loader types (1K-101, K-52, 1GSh-68). The effect of the canopy coefficient on the coefficient of production level is also considered. Recommendations that concern the increase in advance rates during crossing of tectonic disurbances are given.

  9. The influence of incidence angle on disorder production in Cl and Ar ion implanted Si

    International Nuclear Information System (INIS)

    Sukirno; Carter, G.

    1989-01-01

    Cl and Ar ions have been implanted, at 30 keV and at various incidence angles, into Si substrates maintained at room temperature during implantation. Implantation induced Si disorder was measured using Rutherford backscattering channelling. The effects upon disorder of various incidence angles were studied over a fluence range of 10 12 -6·10 15 ions·cm -2 . The results show that, at low fluences Cl and Ar ion implantations generate a bimodal disorder-depth profile, whilst at higher fluences measurements of amorphised layer thickness as a function of ion incidence angle allow values of the standard deviation of the disorder profile parallel and transverse to the ion beam direction for each ion to be obtained in good agreement with theoretical predictions. The disorder-fluence behaviour under these conditions is ion species independent. (author)

  10. The effect of incidence angle on disorder production in ion implanted Si

    International Nuclear Information System (INIS)

    Sukirno; Carter, G.

    1989-01-01

    Ne, Ar, Sb, and Xe ions have been implanted, at 30 keV or 80 keV and at various incidence angles, into Si substrates maintained at room temperature during implantation. Implantation-induced Si disorder was measured using Rutherford backscattering channelling. The effects upon disorder of various incidence angles were studied over a fluence range of 10 12 -10 16 ions·cm -2 . The results show that, at low fluences the lighter (Ne) and slightly heavier (Ar) ion implantations generate a bimodal disorder-depth profile, whilst at higher fluences measurements of amorphised layer thickness as a function of ion incidence angle allow values of the standard deviation of the disorder profile parallel and transverse to the ion beam direction for each ion to be obtained with good agreement to theoretical predictions. (author)

  11. Origami-inspired metamaterial absorbers for improving the larger-incident angle absorption

    International Nuclear Information System (INIS)

    Shen, Yang; Pang, Yongqiang; Wang, Jiafu; Ma, Hua; Pei, Zhibin; Qu, Shaobo

    2015-01-01

    When a folded resistive patch array stands up on a metallic plane, it can exhibit more outstanding absorption performance. Our theoretical investigations and simulations demonstrated that the folded resistive patch arrays can enhance the absorption bandwidth progressively with the increase of the incident angle for the oblique transverse magnetic incidence, which is contrary to the conventional resistive frequency selective surface absorber. On illumination, we achieved a 3D structure metamaterial absorber with the folded resistive patches. The proposed absorber is obtained from the inspiration of the origami, and it has broadband and lager-incident angle absorption. Both the simulations and the measurements indicate that the proposed absorber achieves the larger-incident angle absorption until 75° in the frequency band of 3.6–11.4 GHz. In addition, the absorber is extremely lightweight. The areal density of the fabricated sample is about 0.023 g cm −2 . Due to the broadband and lager-incident angle absorption, it is expected that the absorbers may find potential applications such as stealth technologies and electromagnetic interference. (paper)

  12. Absorptivity modulation on wavy molten steel surfaces: The influence of laser wavelength and angle of incidence

    Science.gov (United States)

    Kaplan, A. F. H.

    2012-10-01

    The modulation of the angle-dependent Fresnel absorptivity across wavy molten steel surfaces during laser materials processing, like drilling, cutting, or welding, has been calculated. The absorptivity is strongly altered by the grazing angle of incidence of the laser beam on the processing front. Owing to its specific Brewster-peak characteristics, the 10.64 μm wavelength CO2-laser shows an opposite trend with respect to roughness and angle-of-incidence compared to lasers in the wavelength range of 532-1070 nm. Plateaus or rings of Brewster-peak absorptivity can lead to hot spots on a wavy surface, often in close proximity to cold spots caused by shadow domains.

  13. A new optical method for measuring surface temperature at large incident probe angles

    Science.gov (United States)

    Lee, A. S.; Norris, P. M.

    1997-02-01

    A novel thermoreflectance technique has been developed for noncontact temperature measurements using laser light incident at large angles on solid materials and devices. The method involves measuring the differential reflectance from a polarization modulated laser beam. The polarization differential reflectance technique is demonstrated on single-crystal Si wafers and on a polycrystalline carbon thin film over a temperature range of 20-60 °C. The method is shown to be an extremely sensitive temperature probe for near grazing angle measurements, which could be useful for monitoring the surface temperature of closely stacked silicon wafers used in batch processing in the microelectronics industry.

  14. Arrival time and incidence angle distributions of extensive air showers (EAS) muons

    International Nuclear Information System (INIS)

    Brancus, I.M.; Duma, M.; Vulpescu, B.; Foeller, M.; Rebel, H.; Voelker, G.; Chilingarian, A.A.

    1995-01-01

    The arrival time distributions of the muons can be related to the longitudinal EAS development and may provide additional information about the nature of the primary. Based on EAS simulations using the Monte-Carlo code CORSIKA, the correlations between arrival time and incidence angle distributions have been investigated in a case of a set of ideal detectors (10 m x 10 m) placed at various distances from the shower core. Applying advanced statistical techniques based on Bayes decision rule and non-parametric multivariate analysing methods it turns out that the correlations of muon arrival time and incidence angle at various separating distances of about 50 m exhibit promising features for mass discrimination (author)

  15. X-ray fluorescence analysis of thin films at glancing-incident and -takeoff angles

    International Nuclear Information System (INIS)

    Tsuji, K.; Sato, S.; Hirokawa, K.

    1995-01-01

    We have developed a new analytical method, Glancing-Incidence and -Takeoff X-Ray Fluorescence (GIT-XRF) method for the first time. Here, we present an idea for a thin-film analysis and a surface analysis by the GIT-XRF method. In this method, the dependence of the fluorescent x-ray intensity on takeoff angle is measured at various incident angles of the primary x-ray. Compared with a total reflection x-ray fluorescence method, the GIT-XRF method allows a detailed thin-film analysis, because the thin film is cross-checked by many experimental curves. Moreover, a surface-sensitive analysis is also possible by the GIT-XRF method. (author)

  16. Grazing-incidence small-angle neutron scattering from structures below an interface.

    Science.gov (United States)

    Nouhi, Shirin; Hellsing, Maja S; Kapaklis, Vassilios; Rennie, Adrian R

    2017-08-01

    Changes of scattering are observed as the grazing angle of incidence of an incoming beam increases and probes different depths in samples. A model has been developed to describe the observed intensity in grazing-incidence small-angle neutron scattering (GISANS) experiments. This includes the significant effects of instrument resolution, the sample transmission, which depends on both absorption and scattering, and the sample structure. The calculations are tested with self-organized structures of two colloidal samples with different size particles that were measured on two different instruments. The model allows calculations for various instruments with defined resolution and can be used to design future improved experiments. The possibilities and limits of GISANS for different studies are discussed using the model calculations.

  17. Note: Grazing incidence small and wide angle x-ray scattering combined with imaging ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Koerstgens, V.; Meier, R.; Ruderer, M. A.; Guo, S.; Chiang, H.-Y.; Mueller-Buschbaum, P. [Technische Universitaet Muenchen, Physik-Department, Lehrstuhl fuer Funktionelle Materialien, James-Franck-Str. 1, 85748 Garching (Germany); Perlich, J.; Roth, S. V.; Gehrke, R. [HASYLAB, DESY, Notkestr. 85, 22607, Hamburg (Germany)

    2012-07-15

    The combination of grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) with optical imaging ellipsometry is presented as an upgrade of the available measurement techniques at the wiggler beamline BW4 of the Hamburger Synchrotronstrahlungslabor. The instrument is introduced with the description of the alignment procedure to assure the measurement of imaging ellipsometry and GISAXS/GIWAXS on the same sample spot. To demonstrate the possibilities of the new instrument examples of morphological investigation on films made of poly(3-hexylthiophene) and [6,6]-phenyl-C{sub 61} butyric acid methyl ester as well as textured poly(9,9-dioctylfluorene-alt-benzo-thia-diazole) are shown.

  18. Performance of silicon pixel detectors at small track incidence angles for the ATLAS Inner Tracker upgrade

    International Nuclear Information System (INIS)

    Viel, Simon; Banerjee, Swagato; Brandt, Gerhard; Carney, Rebecca; Garcia-Sciveres, Maurice; Hard, Andrew Straiton; Kaplan, Laser Seymour; Kashif, Lashkar; Pranko, Aliaksandr; Rieger, Julia; Wolf, Julian; Wu, Sau Lan; Yang, Hongtao

    2016-01-01

    In order to enable the ATLAS experiment to successfully track charged particles produced in high-energy collisions at the High-Luminosity Large Hadron Collider, the current ATLAS Inner Detector will be replaced by the Inner Tracker (ITk), entirely composed of silicon pixel and strip detectors. An extension of the tracking coverage of the ITk to very forward pseudorapidity values is proposed, using pixel modules placed in a long cylindrical layer around the beam pipe. The measurement of long pixel clusters, detected when charged particles cross the silicon sensor at small incidence angles, has potential to significantly improve the tracking efficiency, fake track rejection, and resolution of the ITk in the very forward region. The performance of state-of-the-art pixel modules at small track incidence angles is studied using test beam data collected at SLAC and CERN. - Highlights: • Extended inner pixel barrel layers are proposed for the ATLAS ITk upgrade. • Test beam results at small track incidence angles validate this ATLAS ITk design. • Long pixel clusters are reconstructed with high efficiency at low threshold values. • Excellent angular resolution is achieved using pixel cluster length information.

  19. CALIBRATION OF FULL-WAVEFORM ALS DATA BASED ON ROBUST INCIDENCE ANGLE ESTIMATION

    Directory of Open Access Journals (Sweden)

    F. M. Abed

    2012-09-01

    Full Text Available Full-waveform airborne laser scanning data has shown its potential to enhance available segmentation and classification approaches through the additional information it can provide. However, this additional information is unable to directly provide a valid physical representation of surface features due to many variables affecting the backscattered energy during travel between the sensor and the target. Effectively, this delivers a mis-match between signals from overlapping flightlines. Therefore direct use of this information is not recommended without the adoption of a comprehensive radiometric calibration strategy that accounts for all these effects. This paper presents a practical and reliable radiometric calibration routine by accounting for all the variables affecting the backscattered energy, including the essential factor of angle of incidence. A new robust incidence angle estimation approach has been developed which has proven capable of delivering a reliable estimation for the scattering direction of the individual echoes. The routine was tested and validated both visually and statistically over various land cover types with simple and challenging surface trends. This proved the validity of this approach to deliver the optimal match between overlapping flightlines after calibration, particularly by adopting a parameter which accounts for the angle of incidence effect.

  20. Performance of silicon pixel detectors at small track incidence angles for the ATLAS Inner Tracker upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Viel, Simon, E-mail: sviel@lbl.gov [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Banerjee, Swagato [Department of Physics, University of Wisconsin, Madison, WI, United States of America (United States); Brandt, Gerhard; Carney, Rebecca; Garcia-Sciveres, Maurice [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Hard, Andrew Straiton; Kaplan, Laser Seymour; Kashif, Lashkar [Department of Physics, University of Wisconsin, Madison, WI, United States of America (United States); Pranko, Aliaksandr [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Rieger, Julia [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); II Physikalisches Institut, Georg-August-Universität, Göttingen (Germany); Wolf, Julian [Physics Division, Lawrence Berkeley National Laboratory and University of California, Berkeley, CA, United States of America (United States); Wu, Sau Lan; Yang, Hongtao [Department of Physics, University of Wisconsin, Madison, WI, United States of America (United States)

    2016-09-21

    In order to enable the ATLAS experiment to successfully track charged particles produced in high-energy collisions at the High-Luminosity Large Hadron Collider, the current ATLAS Inner Detector will be replaced by the Inner Tracker (ITk), entirely composed of silicon pixel and strip detectors. An extension of the tracking coverage of the ITk to very forward pseudorapidity values is proposed, using pixel modules placed in a long cylindrical layer around the beam pipe. The measurement of long pixel clusters, detected when charged particles cross the silicon sensor at small incidence angles, has potential to significantly improve the tracking efficiency, fake track rejection, and resolution of the ITk in the very forward region. The performance of state-of-the-art pixel modules at small track incidence angles is studied using test beam data collected at SLAC and CERN. - Highlights: • Extended inner pixel barrel layers are proposed for the ATLAS ITk upgrade. • Test beam results at small track incidence angles validate this ATLAS ITk design. • Long pixel clusters are reconstructed with high efficiency at low threshold values. • Excellent angular resolution is achieved using pixel cluster length information.

  1. Polarimetric Scattering Properties of Landslides in Forested Areas and the Dependence on the Local Incidence Angle

    Directory of Open Access Journals (Sweden)

    Takashi Shibayama

    2015-11-01

    Full Text Available This paper addresses the local incidence angle dependence of several polarimetric indices corresponding to landslides in forested areas. Landslide is deeply related to the loss of human lives and their property. Various kinds of remote sensing techniques, including aerial photography, high-resolution optical satellite imagery, LiDAR and SAR interferometry (InSAR, have been available for landslide investigations. SAR polarimetry is potentially an effective measure to investigate landslides because fully-polarimetric SAR (PolSAR data contain more information compared to conventional single- or dual-polarization SAR data. However, research on landslide recognition utilizing polarimetric SAR (PolSAR is quite limited. Polarimetric properties of landslides have not been examined quantitatively so far. Accordingly, we examined the polarimetric scattering properties of landslides by an assessment of how the decomposed scattering power components and the polarimetric correlation coefficient change with the local incidence angle. In the assessment, PolSAR data acquired from different directions with both spaceborne and airborne SARs were utilized. It was found that the surface scattering power and the polarimetric correlation coefficient of landslides significantly decrease with the local incidence angle, while these indices of surrounding forest do not. This fact leads to establishing a method of effective detection of landslide area by polarimetric information.

  2. Beam test measurements on GaAs pixel detectors at various angles of incidence

    Energy Technology Data Exchange (ETDEWEB)

    Braunschweig, W.; Breibach, J.; Graessel, D.; Koenig, St.; Kubicki, Th.; Luebelsmeyer, K.; Rente, C.; Roeper, Ch.; Siedling, R.; Syben, O.; Tenbusch, F.; Toporowski, M.; Xiao, W.J

    1999-08-01

    A GaAs pixel detector constructed in Aachen has been tested in a 4 GeV electron beam at DESY. The experimental setup allowed tilting the detector with respect to the beam line with angles of incidence from 0 deg. to 45 deg. . The sensor-array consisted of 8 x 16 pixels with a size of 125 x 125{mu}m{sup 2} each. The detector was made of a 250{mu}m thick Freiberger SI-GaAs wafer. An improved contact was formed on the backside, allowing safe operation of the detector in the soft breakdown regime. A double metal technique allowed bonding the single pixels linearly to the readout-chip. Using the the fast PreMux128 preamplifier multiplexer chip ({tau}{sub p} = 40ns) a signal to noise ratio of 29 was obtained for a beam angle of incidence of 0 deg. increasing up to 38 for 45 deg. The spatial resolution obtained with an angle of incidence of 45 deg. was (9.0 {+-} 6.0){mu}m while the resolution of the untilted detector is equal to the digital one (36.1{mu}m). For these testbeam-measurements the detector was connected to the electronics via wire-bonds. For future experiments bump-bonding connections are required. The results of a process for the formation of bump-bond connections on GaAs pixeldetectors are shown.

  3. Modeling Radar Scattering by Planetary Regoliths for Varying Angles of Incidence

    Science.gov (United States)

    Prem, P.; Patterson, G. W.; Zimmerman, M. I.

    2017-12-01

    Bistatic radar observations can play an important role in characterizing the texture and composition of planetary regoliths. Multiple scattering within a closely-packed particulate medium, such as a regolith, can lead to a response referred to as the Coherent Backscatter Opposition Effect (CBOE), associated with an increase in the intensity of backscattered radiation and an increase in Circular Polarization Ratio (CPR) at small bistatic angles. The nature of the CBOE is thought to depend not only on regolith properties, but also on the angle of incidence (Mishchenko, 1992). The latter factor is of particular interest in light of recent radar observations of the Moon over a range of bistatic and incidence angles by the Mini-RF instrument (on board the Lunar Reconnaissance Orbiter), operating in bistatic mode with a ground-based transmitter at the Arecibo Observatory. These observations have led to some intriguing results that are not yet well-understood ­- for instance, the lunar South Polar crater Cabeus shows an elevated CPR at only some combinations of incidence angle/bistatic angle, a potential clue to the depth distribution of water ice at the lunar poles (Patterson et al., 2017). Our objective in this work is to develop a model for radar scattering by planetary regoliths that can assist in the interpretation of Mini-RF observations. We approach the problem by coupling the Multiple Sphere T-Matrix (MSTM) code of Mackowski and Mishchenko (2011) to a Monte Carlo radiative transfer model. The MSTM code is based on the solution of Maxwell's equations for the propagation of electromagnetic waves in the presence of a cluster of scattering/absorbing spheres, and can be used to model the scattering of radar waves by an aggregation of nominal regolith particles. The scattering properties thus obtained serve as input to the Monte Carlo model, which is used to simulate radar scattering at larger spatial scales. The Monte Carlo approach has the advantage of being able to

  4. Simulation of the effect of incline incident angle in DMD Maskless Lithography

    Science.gov (United States)

    Liang, L. W.; Zhou, J. Y.; Xiang, L. L.; Wang, B.; Wen, K. H.; Lei, L.

    2017-06-01

    The aim of this study is to provide a simulation method for investigation of the intensity fluctuation caused by the inclined incident angle in DMD (digital micromirror device) maskless lithography. The simulation consists of eight main processes involving the simplification of the DMD aperture function and light propagation utilizing the non-parallel angular spectrum method. These processes provide a possibility of co-simulation in the spatial frequency domain, which combines the microlens array and DMD in the maskless lithography system. The simulation provided the spot shape and illumination distribution. These two parameters are crucial in determining the exposure dose in the existing maskless lithography system.

  5. Treatment of Angle Class II malocclusions with a newly modified bionator combined with headgear

    Directory of Open Access Journals (Sweden)

    Yen-Chun Lin

    2009-06-01

    Full Text Available The bionator is one of the most commonly used functional appliances in treating Angle Class II division 1 malocclusions. However, the original type of bionator often causes lower incisor flaring and is limited in cases with mild crowding. There is little published literature on treating Angle Class II division 2 malocclusions using bionators. Our group suggested some modifications to the original-type bionator, including addition of an anterior resin cap, upper and lower labial bows, an expansion screw and a posterior resin wedge, to attempt to overcome limitations of the original design. This article shows our results on two male patients, one with an Angle Class II division 1 malocclusion with a large overjet and the other with an Angle Class II division 2 malocclusion. The treatment was completed using a newly modified bionator with no other fixed appliance and resulted in a decrease in facial convexity, a reduced overjet and overbite, ideal interincisal relationships, and a harmonious profile.

  6. Transmission of electrons through insulating PET foils: Dependence on charge deposition, tilt angle and incident energy

    Energy Technology Data Exchange (ETDEWEB)

    Keerthisinghe, D., E-mail: darshika.keerthisinghe@wmich.edu [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States); Dassanayake, B.S. [Department of Physics, University of Peradeniya, Peradeniya (Sri Lanka); Wickramarachchi, S.J. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States); Stolterfoht, N. [Helmholtz-Zentrum Berlin für Materialien und Energie, D-14109 Berlin (Germany); Tanis, J.A. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States)

    2016-09-01

    Transmission of electrons through insulating polyethylene terephthalate (PET) nanocapillaries was observed as a function of charge deposition, angular and energy dependence. Two samples with capillary diameters 100 and 200 nm and pore densities 5 × 10{sup 8}/cm{sup 2} and 5 × 10{sup 7}/cm{sup 2}, respectively, were studied for incident electron energies of 300, 500 and 800 eV. Transmission and steady state of the electrons were attained after a time delay during which only a few electron counts were observed. The transmission through the capillaries depended on the tilt angle with both elastic and inelastic electrons going through. The guiding ability of electrons was found to increase with the incident energy in contrast to previous measurements in our laboratory for a similar PET foil.

  7. Incident-angle dependency found in track formation sensitivity of a plastic nuclear track detector (TD-1)

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    1999-01-01

    The present study was done since data are hardly available on the incident-angle dependency of track formation sensitivity (S) of the plastic nuclear track detector. Chips of a TD-1 plate, an antioxidant-doped CR-39 (diethyleglycol-bis-allylcarbonate, HARZLAS, Fukuvi Chem. Ind.), were used as a high-LET radiation detector and were exposed to heavy ion beams of C, Ne, and Si under different incident angles in Heavy Ion Medical Accelerator in Chiba of National Institute of Radiological Sciences. After exposed and etched, the chips were observed with an optical microscope and a program for image analysis to calculate S. The S values calculated were found smaller for the beams having lower incident angles. Thus the estimated LET values from the S-LET relationship for vertical incident beams showed large reduction for low-angle particles. Those potential errors should be quantified and corrected in determination of LET spectra in space. (K.H.)

  8. A light incident angle switchable ZnO nanorod memristor: reversible switching behavior between two non-volatile memory devices.

    Science.gov (United States)

    Park, Jinjoo; Lee, Seunghyup; Lee, Junghan; Yong, Kijung

    2013-11-26

    A light incident angle selectivity of a memory device is demonstrated. As a model system, the ZnO resistive switching device has been selected. Electrical signal is reversibly switched between memristor and resistor behaviors by modulating the light incident angle on the device. Moreover, a liquid passivation layer is introduced to achieve stable and reversible exchange between the memristor and WORM behaviors. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Influence of crack opening and incident wave angle on second harmonic generation of Lamb waves

    Science.gov (United States)

    Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei

    2018-05-01

    Techniques utilising second harmonic generation (SHG) have proven their great potential in detecting contact-type damage. However, the gap between the practical applications and laboratory studies is still quite large. The current work is aimed to bridge this gap by investigating the effects of the applied load and incident wave angle on the detectability of fatigue cracks at various lengths. Both effects are critical for practical implementations of these techniques. The present experimental study supported by three-dimensional (3D) finite element (FE) modelling has demonstrated that the applied load, which changes the crack opening and, subsequently, the contact nonlinearity, significantly affects the amplitude of the second harmonic generated by the fundamental symmetric mode (S0) of Lamb wave. This amplitude is also dependent on the length of the fatigue crack as well as the incident wave angle. The experimental and FE results correlate well, so the modelling approach can be implemented for practical design of damage monitoring systems as well as for the evaluation of the severity of the fatigue cracks.

  10. Wakes behind surface-mounted obstacles: Impact of aspect ratio, incident angle, and surface roughness

    Science.gov (United States)

    Tobin, Nicolas; Chamorro, Leonardo P.

    2018-03-01

    The so-called wake-moment coefficient C˜h and lateral wake deflection of three-dimensional windbreaks are explored in the near and far wake. Wind-tunnel experiments were performed to study the functional dependence of C˜h with windbreak aspect ratio, incidence angle, and the ratio of the windbreak height and surface roughness (h /z0 ). Supported with the data, we also propose basic models for the wake deflection of the windbreak in the near and far fields. The near-wake model is based on momentum conservation considering the drag on the windbreak, whereas the far-wake counterpart is based on existing models for wakes behind surface-mounted obstacles. Results show that C˜h does not change with windbreak aspect ratios of 10 or greater; however, it may be lower for an aspect ratio of 5. C˜h is found to change roughly with the cosine of the incidence angle, and to depend strongly on h /z0 . The data broadly support the proposed wake-deflection models, though better predictions could be made with improved knowledge of the windbreak drag coefficient.

  11. Large-angle production of charged pions with incident pion beams on nuclear targets

    CERN Document Server

    Apollonio, M.; Bagulya, A.; Barr, G.; Blondel, A.; Bobisut, F.; Bogomilov, M.; Bonesini, M.; Booth, C.; Borghi, S.; Bunyatov, S.; Burguet-Castell, J.; Catanesi, M.G.; Cervera-Villanueva, A.; Chimenti, P.; Coney, L.; Di Capua, E.; Dore, U.; Dumarchez, J.; Edgecock, R.; Ellis, M.; Ferri, F.; Gastaldi, U.; Giani, S.; Giannini, G.; Gibin, D.; Gilardoni, S.; Gorbunov, P.; Gossling, C.; Gomez-Cadenas, J.J.; Grant, A.; Graulich, J.S.; Gregoire, G.; Grichine, V.; Grossheim, A.; Guglielmi, A.; Howlett, L.; Ivanchenko, A.; Ivanchenko, V.; Kayis-Topaksu, A.; Kirsanov, M.; Kolev, D.; Krasnoperov, A.; Martin-Albo, J.; Meurer, C.; Mezzetto, M.; Mills, G.B.; Morone, M.C.; Novella, P.; Orestano, D.; Palladino, V.; Panman, J.; Papadopoulos, I.; Pastore, F.; Piperov, S.; Polukhina, N.; Popov, B.; Prior, G.; Radicioni, E.; Schmitz, D.; Schroeter, R.; Skoro, G.; Sorel, M.; Tcherniaev, E.; Temnikov, P.; Tereschenko, V.; Tonazzo, A.; Tortora, L.; Tsenov, R.; Tsukerman, I.; Vidal-Sitjes, G.; Wiebusch, C.; Zucchelli, P.

    2009-01-01

    Measurements of the double-differential pi+/- production cross-section in the range of momentum 100 MeV/c <= p <= 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad using pi+/- beams incident on beryllium, aluminium, carbon, copper, tin, tantalum and lead targets are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN PS. The secondary pions were produced by beams in a momentum range from 3 GeV/c to 12.9 GeV/c hitting a solid target with a thickness of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using a small-radius cylindrical time projection chamber (TPC) placed inside a solenoidal magnet. Incident particles were identified by an elaborate system of beam detectors. Results are obtained for the double-differential cross-sections d2sigma/dpdtheta at six incident beam momenta. Data at 3 GeV/c, 5 GeV/c, 8 GeV/c, and 12 GeV/c are available for all targets while additional data at 8.9 GeV/...

  12. Study of a Modified AC Bridge Technique for Loss Angle Measurement of a Dielectric Material

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2008-09-01

    Full Text Available A Wheatstone’s bridge network like Schering Bridge, DeSauty Bridge etc measures the loss angle or tangent of loss angle (tanδ of a dielectric material. In high voltage application this loss angle is generally measured by high voltage Schering Bridge. But continuous measurement of tan δ is not possible by these techniques. In the present paper a modified operational amplifiers based Schering Bridge network has been proposed for continuous measurement of tanδ in the form of a bridge network output voltage. Mathematical analysis of the proposed bridge network has been discussed in the paper and experimental work has been performed assuming the lossy dielectric material as a series combination of loss less capacitor and a resistor. Experimental results are reported in the paper. From the mathematical analysis and experimental results it is found that the output of the proposed bridge network is almost linearly related with tanδ.

  13. Edge contact angle and modified Kelvin equation for condensation in open pores.

    Science.gov (United States)

    Malijevský, Alexandr; Parry, Andrew O; Pospíšil, Martin

    2017-08-01

    We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H=∞) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure p_{cc}(L;H) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θ_{e} that is always larger than the equilibrium contact angle θ, only equal to it in the limit of macroscopic H. For walls that are completely wet (θ=0) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θ_{e}≈sqrt[πL/2H] for large H. Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature T_{w} we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above T_{w} the modified Kelvin equation only becomes accurate for much larger systems.

  14. Association of open-angle glaucoma loci with incident glaucoma in the Blue Mountains Eye Study.

    Science.gov (United States)

    Burdon, Kathryn P; Mitchell, Paul; Lee, Anne; Healey, Paul R; White, Andrew J R; Rochtchina, Elena; Thomas, Peter B M; Wang, Jie Jin; Craig, Jamie E

    2015-01-01

    To determine if open-angle glaucoma (OAG)-associated single nucleotide polymorphisms (SNPs) are associated with incident glaucoma and if such genetic information is useful in OAG risk prediction. Case-control from within a population-based longitudinal study. study population: Individuals aged over 49 years of age living in the Blue Mountains region west of Sydney and enrolled in the Blue Mountains Eye Study. observation: Cases for this sub-study (n = 67) developed incident OAG between baseline and 10-year visits, in either eye, while controls (n = 1919) had no evidence for OAG at any visit. All participants had an ocular examination and DNA genotyped for reported OAG risk SNPs. main outcome measure: Incident OAG. Two loci also known to be associated with cup-to-disc ratio as well as OAG (9p21 near CDKN2B-AS1 and SIX1/SIX6) were both significantly associated with incident OAG in the Blue Mountains Eye Study cohort (P = .006 and P = .004, respectively). The TMCO1 locus was nominally associated (P = .012), while the CAV1/CAV2 and 8q22 loci were not associated. Multivariate logistic regression and neural network analysis both indicated that the genetic risk factors contributed positively to the predictive models incorporating traditional risk factors. This study shows that previously reported genetic variations related to OAG and cup-to-disc ratio are associated with the onset of OAG and thus may become useful in risk prediction algorithms designed to target early treatment to those most at risk of developing glaucoma. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  15. ASSESMENT AND EVLUATION OF THE IMPACT OF USING POLSAR IMAGERIES WITH DIFERENT INCIDENT ANGLES IN FOREST CLASSIFICATION

    Directory of Open Access Journals (Sweden)

    K. Ranjbar

    2013-09-01

    Full Text Available Forests are a dominant biome of the earth and have an important impact on its economic and environmental well-being. Forestry applications of radar remote sensing are addressed in the context of both forest management and ecosystem understanding, modelling and monitoring. Nowadays, radar remote sensing is being used for a lot of applications in various fields. Due to the applications of polarimetric radar in recent decades, many researchers have tended to this field. One of the main advantages of SAR images is that these images are independent over the time (day and night and weather condition. The polarimetric SAR (POLSAR images compared with other remote sensing images are more informative. Classification of radar images is a way by which we can separate different types of forest species. In addition to the main characteristics of the target, the backscatter from a SAR image is widely dependant on various radar system parameters. One of these system parameters is the incident angle of the radar system. In this paper, the impact of using PolSAR images with different incidence angles for the classification of forest areas is investigated. Two polSAR images with different incident angles taken by RADARSAT-2 in fine quad polarized mode (FQ4 and FQ18 have been used in this study. The study area is located in the Petawawa Research Forest (PRF near Chalk River, Ontario, Canada The methodology of this paper contains three steps: (1 preprocessing, (2 wishart classification and (3 evaluating & analyzing the results. The preprocessing steps consist of the speckle noise filtering, covariance matrix extraction and georeferencing. In the second step, each incidence angle image was classified by using the supervised Wishart classification. The Wishart classification method has the capability of having multiple images at the same time. Thus, in the next experiment the classification was performed using both incidence angle images. Finally, the obtained

  16. Assesment and Evluation of the Impact of Using Polsar Imageries with Diferent Incident Angles in Forest Classification

    Science.gov (United States)

    Ranjbar, K.; Maghsoudi, Y.; Sahebi, M. R.

    2013-09-01

    Forests are a dominant biome of the earth and have an important impact on its economic and environmental well-being. Forestry applications of radar remote sensing are addressed in the context of both forest management and ecosystem understanding, modelling and monitoring. Nowadays, radar remote sensing is being used for a lot of applications in various fields. Due to the applications of polarimetric radar in recent decades, many researchers have tended to this field. One of the main advantages of SAR images is that these images are independent over the time (day and night) and weather condition. The polarimetric SAR (POLSAR) images compared with other remote sensing images are more informative. Classification of radar images is a way by which we can separate different types of forest species. In addition to the main characteristics of the target, the backscatter from a SAR image is widely dependant on various radar system parameters. One of these system parameters is the incident angle of the radar system. In this paper, the impact of using PolSAR images with different incidence angles for the classification of forest areas is investigated. Two polSAR images with different incident angles taken by RADARSAT-2 in fine quad polarized mode (FQ4 and FQ18) have been used in this study. The study area is located in the Petawawa Research Forest (PRF) near Chalk River, Ontario, Canada The methodology of this paper contains three steps: (1) preprocessing, (2) wishart classification and (3) evaluating & analyzing the results. The preprocessing steps consist of the speckle noise filtering, covariance matrix extraction and georeferencing. In the second step, each incidence angle image was classified by using the supervised Wishart classification. The Wishart classification method has the capability of having multiple images at the same time. Thus, in the next experiment the classification was performed using both incidence angle images. Finally, the obtained results from each

  17. Characterization of surface Ag nanoparticles in nanocomposite a-C:Ag coatings by grazing incidence X-ray diffraction at sub-critical angles of incidence

    Energy Technology Data Exchange (ETDEWEB)

    Manninen, N.K.; Oliveira, J.C.; Cavaleiro, A. [University of Coimbra, SEG-CEMUC, Mechanical Engineering Department, Coimbra (Portugal); Carvalho, S. [University of Minho, GRF-CFUM, Physics Department, Guimaraes (Portugal)

    2016-03-15

    Silver diffusion within nanocomposite films and/or toward the film surface is often observed during annealing of the silver-based nanocomposite films. In order to control and/or minimize this process, it is crucial to characterize the aggregated silver nanoparticles on the films surface. In this paper grazing incidence X-ray diffraction (GIXRD) with both sub-critical and supra-critical angles of incidence is used to characterize the Ag nanoparticles distribution, shape and structure both inside the matrix and on the nanocomposite film surface. The nanocomposite carbon coating containing Ag nanoparticles (a-C:Ag) was deposited by dc magnetron sputtering. The coatings were analyzed by GIXRD using fixed incident angles both below and above the critical angle for total reflection. By using sub-critical angles it was possible to eliminate diffraction from the bulk material allowing to estimate the size distribution of the nanoparticles sitting on the surface. The results obtained by GIXRD analysis were checked through comparison with the observations made by both TEM and SEM analysis. The proposed methodology can be used to characterized nanoparticles deposition on a surface and/or island formation during film growth as long an adequate substrate with high critical angle for total reflection is used. (orig.)

  18. Dispersion measurement on chirped mirrors at arbitrary incidence angle and polarization state (Conference Presentation)

    Science.gov (United States)

    Kovacs, Mate; Somoskoi, Tamas; Seres, Imre; Borzsonyi, Adam; Sipos, Aron; Osvay, Károly

    2017-05-01

    The optical elements of femtosecond high peak power lasers have to fulfill more and more strict requirements in order to support pulses with high intensity and broad spectrum. In most cases chirped pulse amplification scheme is used to generate high peak power ultrashort laser pulses, where a very precise control of spectral intensity and spectral phase is required in reaching transform-limited temporal shape at the output. In the case of few cycle regime, the conventional bulk glass, prism-, grating- and their combination based compressors are not sufficient anymore, due to undesirable nonlinear effects in their material and proneness to optical damages. The chirped mirrors are also commonly used to complete the compression after a beam transport system just before the target. Moreover, the manufacturing technology requires quality checks right after production and over the lifetime of the mirror as well, since undesired deposition on the surface can lead alteration from the designed value over a large part of the aperture. For the high harmonic generation, polarization gating technology is used to generate single attosecond pulses [1]. In this case the pulse to be compressed has various polarization state falling to the chirped mirrors. For this reason, it is crucial to measure the dispersion of the mirrors for the different polarization states. In this presentation we demonstrate a simple technique to measure the dispersion of arbitrary mirror at angles of incidence from 0 to 55 degree, even for a 12" optics. A large aperture 4" mirror has been scanned over with micrometer accuracy and the dispersion property through the surface has been investigated with a stable interference fringes in that robust geometry. We used Spectrally Resolved Interferometry, which is based on a Michaelson interferometer and a combined visible and infrared spectrometer. Tungsten halogen lamp with 10 mW coupled optical power was used as a white-light source so with the selected

  19. Tectonic Features in the Equatorial Lowlands of Mercury Viewed at High Incidence Angles

    Science.gov (United States)

    Selvans, M. M.; Watters, T. R.; Solomon, S. C.

    2012-12-01

    The spatial distribution of tectonic features on Mercury, although not fully understood, is related to the stress regime and the mechanical properties of the lithosphere during the time that the features formed and remained active. Lobate scarps and high-relief ridges, compressional features that generally have ~1 km of relief and are hundreds of kilometers long, were identified on Mercury from images acquired during the Mariner 10 and MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) flybys. Images taken from orbit during the primary MESSENGER mission, with full coverage of the surface, confirmed that these scarps and ridges appear to be concentrated in three broad, north-south bands. Images at high incidence angles, collected since April 2012 during the MESSENGER extended mission, provide a more complete picture of the spatial extent and orientations of these features, and of their relationship to neighboring landforms. Digital elevation models, from laser altimetry and stereo imaging, additionally allow for comparisons between tectonic landforms and elevation and for measurements of slope and relief across individual features. Scarps and ridges are found at a wide range of elevations on Mercury. The greatest concentration of such features in an equatorial lowland setting is in an area (40°N-40°S, 220°-270°E) that is within one of the three north-south bands of tectonic features. Within this area, the 48 previously mapped features generally do not display preferred orientations or a consistent relationship to topography. Of these scarps, 47 were identified in flyby images and one in orbital images. Three follow the rim of Beethoven basin (10°-30°S, 225-245°E, ~600 km diameter), likely having formed along earlier zones of weakness in the crust created during formation of the basin. From recent images taken at high incidence angles, which currently have ~75% coverage in this equatorial lowland area, we are able to identify only seven

  20. Modified Frye-Morris polynomial model for double web-angle connections

    Science.gov (United States)

    Prabha, P.; Rekha, S.; Marimuthu, V.; Saravanan, M.; Palani, G. S.; Surendran, M.

    2015-09-01

    The polynomial model proposed by Frye-Morris is generally used to predict the moment-rotation behaviour of eight types of angle connections. The problem with the Frye-Morris model is that it either overestimates or underestimates the connection stiffness as it was developed by assimilating only few test results. A nominal air-gap distance of 10 mm is provided between beam and column, while assembling the connections for fabrication conveniences. This air-gap distance has considerable influence on the connection behaviour observed from the previous studies and an improved polynomial model was suggested for top and seat-angle connection based on the numerical parametric studies by considering the air-gap distance as an additional size parameter. In line with this, the Frye-Morris model for double web-angle connection is also modified based on numerical parametric studies. A new equation is proposed based on the Frye-Morris procedure with air gap as an additional parameter. The proposed equation is compared with the experimental results and Frye-Morris model and is found to be in close agreement.

  1. Studies on polymer thin film structure by X-ray and neutron reflectivity and grazing incidence small angle scattering

    International Nuclear Information System (INIS)

    Ogawa, Hiroki; Kanaya, Toshiji

    2011-01-01

    We have reviewed structure studies of polymer thin films using synchrotron radiation X-ray and neutron reflectivity as well as recently developed grazing incidence small-angle X-ray and neutron scattering, including studies on polymer thin films with embedded ordered nanometer cells, distribution of glass transition temperature Tg in thin polystyrene films, and dewetting process of polymer blend thin films. (author)

  2. MESS MDIS MAP PROJ LOW-INCIDENCE ANGLE BASEMAP RDR V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== The Mercury Dual Imaging System (MDIS) consists of two cameras, a Wide Angle Camera (WAC) and a Narrow Angle Camera (NAC), mounted on a common...

  3. Mercury's radius change estimates revisited using high incidence angle MESSENGER data

    Science.gov (United States)

    Di Achille, G.; Popa, C.; Massironi, M.; Ferrari, S.; Mazzotta Epifani, E.; Zusi, M.; Cremonese, G.; Palumbo, P.

    2012-04-01

    Estimates of Mercury's radius decrease obtained using the amount of strain recorded by tectonics on the planet range from 0.5 km to 2 km. These latter figures appear too low with respect to the radius contraction (up to 5-6 km) predicted by the most accredited studies based on thermo-mechanical evolution models. For this reason, it has been suggested that there may be hidden strain accommodated by features yet unseen on Mercury. Indeed, as it has been already cautioned by previous studies, the identification of tectonic features on Mercury might be largely biased by the lighting geometry of the used basemaps. This limitation might have affected the results of the extrapolations for estimating the radius change. In this study, we mapped tectonic features at the terminator thus using images acquired at high sun incidence angle (>50°) that represents the optimal condition for their observation. In fact, images with long shadows enhance the topography and texture of the surface and are ideal to detect tectonic structures. This favorable illumination conditions allowed us to infer reliable measurements of spatial distribution (i.e. frequency, orientation, and areal density) of tectonic features which can be used to estimate the average contractional strain and planetary radius decrease. We digitized tectonic structures within a region extending for an area of about 12 million sq. km (~16% of planet's surface). More than 1300 tectonic lineaments were identified and interpreted to be compressional features (i.e. lobate scarps, wrinkle ridges, and high relief ridges) with a total length of more than 12300 km. Assuming that the extensional strain is negligible within the area, the average contractional strain calculated for the survey area is ~0.21-0.28% (~0.24% for θ=30°). This strain, extrapolated to the entire surface, corresponds to a contraction in radius of about 2.5-3.4 km (~2.9 km for θ=30°). Interestingly, the values of contractional strain and radius decrease

  4. Difference between the Brewster angle and angle of minimum reflectance for incident unpolarized or circularly polarized light at interfaces between transparent media.

    Science.gov (United States)

    Azzam, R M A

    2015-06-01

    For reflection at interfaces between transparent optically isotropic media, the difference between the Brewster angle ϕB of zero reflectance for incident p-polarized light and the angle ϕu min of minimum reflectance for incident unpolarized or circularly polarized light is considered as function of the relative refractive n in external and internal reflection. We determine the following. (i) ϕu min reflection (n > 1), the maximum difference (ϕB - ϕu min)max = 75° at n = 2 + √3. (iii) In internal reflection and 0 reflectance R0 at normal incidence is in the range 0 ≤ R0 ≤ 1/3, ϕu min = 0, and ϕB - ϕu min = ϕB. (v) For internal reflection and 0 < n < 2 - √3, ϕu min exhibits an unexpected maximum (= 12.30°) at n = 0.24265. Finally, (vi) for 1/3 ≤ R0 < 1, Ru min at ϕu min is limited to the range 1/3 ≤ Ru min < 1/2.

  5. Impact and Penetration of Thin Aluminum 2024 Flat Panels at Oblique Angles of Incidence

    Science.gov (United States)

    Ruggeri, Charles R.; Revilock, Duane M.; Pereira, J. Michael; Emmerling, William; Queitzsch, Gilbert K., Jr.

    2015-01-01

    under more extreme conditions, using a projectile with a more complex shape and sharp contacts, impacting flat panels at oblique angles of incidence.

  6. Influence of the incidence angle on the morphology of enamel and dentin under Er:YAG laser irradiation

    International Nuclear Information System (INIS)

    Junqueira Junior, Duilio Naves

    2002-01-01

    The purpose of this study is to make an in vitro evaluation, using scanning electron microscopy, of the influence of the laser beam irradiation angle on the enamel and dentin morphology. These tissues were both irradiated by Er:YAG Laser, with the same energy parameter. Twenty-four incisive bovine teeth were used, separated in eight groups, four of enamel, and four of dentin, with three specimens in each group. Each specimen was submitted to three laser applications, varying the incidence angle, between the laser and the tooth surface, at 90, 50 and 20 degrees. The applied frequency was 2 Hz, with 20 pulses in each application. The KaVo Key Laser 3 was employed, wavelength at 2940 nm, adjustable energy from 40 to 600 mJ and repetition rate from 1 to 25 Hz. The groups were distributed according to the energy parameter as follows - enamel: 250 mJ; 300 mJ; 350 mJ and 400 mJ; dentin: 200 mJ; 250 mJ; 300 mJ and 350 mJ. The results evidenced the Laser incidence angle importance; it is an essential parameter in the protocol of utilization and it should not be disregarded. The observations of this study allow to conclude that the Laser incidence angle has direct influence on the morphological aspect of the alterations produced in enamel and dentin. (author)

  7. Contact angle analysis of low-temperature cyclonic atmospheric pressure plasma modified polyethylene terephthalate

    International Nuclear Information System (INIS)

    Huang, Chun; Chang, Ya-Chi; Wu, Shin-Yi

    2010-01-01

    Polyethylene terephthalate (PET) films are modified by cyclonic atmospheric pressure plasma. The experimentally measured gas phase temperature was around 30 o C to 90 o C, indicating that this cyclonic atmospheric pressure plasma can treat polymers without unfavorable thermal effects. The surface properties of cyclonic atmospheric pressure plasma-treated PET films were examined by the static contact angle measurements. The influences of plasma conditions such as treatment time, plasma power, nozzle distance, and gas flow rate on the PET surface properties were studied. It was found that such cyclonic atmospheric pressure plasma is very effective in PET surface modification, the reduced water contact angle was observed from 74 o to less than 37 o with only 10 s plasma treatment. The chemical composition of the PET films was analyzed by X-ray photoelectron spectroscopy (XPS). Atomic force microscopy (AFM) was used to study the changes in PET surface feature of the polymer surfaces due to plasma treatment. The photoemission plasma species in the continuous cyclone atmospheric pressure plasma was identified by optical emission spectroscopy (OES). From OES analysis, the plasma modification efficiency can be attributed to the interaction of oxygen-based plasma species in the plasma with PET surface. In this study, it shows a novel way for large scale polymeric surface modification by continuous cyclone atmospheric pressure plasma processing.

  8. Modified bisecting angle technique in eliminating zygomatic superimposition over apices of maxillary molars.

    Science.gov (United States)

    Jamdade, Anshuman S

    2014-01-01

    Image superimposition is a part and parcel of two-dimensional radiography. However, some overlappings are a result of radiographic technique itself. The technique induced superimposition of zygomatic buttress on apices of maxillary molars is common in bisecting angle technique (BAT), which affects the endodontic performance. Certain alterations were carried out in BAT to remove these undiagnostic shadows. The aim of this study was to compare two techniques of periapical radiography namely, BAT and modified BAT (MBAT) in preventing zygomatic superimposition over apices of maxillary molars. A total of 62 patients requiring endodontic treatment for at least one maxillary molar were recruited in this cross-sectional study. One tooth from every patient was subjected for two periapical radiographs, one with each BAT and MBAT respectively giving a total of 124 radiographs. Each radiograph was recorded as acceptable or unacceptable, based on zygomatic superimposition and different technical aspects. Chi-square test was used for data analysis. The kappa statistic was used to test intra-observer reliability. With MBAT, the acceptability was 82.3% (n = 51) compared with 43.5% (n = 27) when BAT was employed. The statistically significant difference was found between these two techniques (P = 0.000). The level of agreement between two oral radiologists in their interpretation was high (kappa index = 0.897). Modified BAT was more accurate for periapical radiography of maxillary molars in preventing zygomatic superimposition and related technical errors than BAT.

  9. Asymmetry of magneto-optical Kerr effect loops of Co nano-columns grown by oblique incident angle deposition

    International Nuclear Information System (INIS)

    Tang, F.; Liu, D.-L.; Ye, D.-X.; Lu, T.-M.; Wang, G.-C.

    2004-01-01

    Magneto-optical Kerr effect (MOKE) in the longitudinal mode was used to measure the in-plane magnetic anisotropy of about 300nm thick Co nano-column films that were grown by e-beam evaporation at different oblique incident angles (0-85 o ) on native SiO 2 substrates at room temperature. The symmetry of MOKE loops measured at azimuthal angles that are 180 o apart is obviously broken for Co nano-column films grown at high deposition angles >70 o . The plot of coercivity H c of loops versus azimuthal angle shows that H c values for azimuthal angles between -90 o and 90 o are much larger than the values for azimuthal angles between 90 o and 270 o . The asymmetry of coercivity is due to MOKE measurement that combines both longitudinal and polar Kerr effects. This combination is caused by the oblique magnetic anisotropy associated with the tilted Co nano-columns. A method is introduced to separate the longitudinal and polar Kerr effects. The longitudinal Kerr effect is obtained by adding hysteresis loops measured at azimuthal angles 180 o apart while the polar Kerr effect is obtained by subtracting these two loops. By comparing these two orthogonal magnetization components represented by longitudinal and polar Kerr effects, we show that magnetization rotation exists in the magnetic reversal process even at azimuthal angle φ=0 o that is the closest in-plane direction to the easy axis. After separating these two Kerr effects, the two-fold symmetry of coervicity associated with tilted nano-columns measured by longitudinal Kerr effect is restored

  10. Laser warning receiver to identify the wavelength and angle of arrival of incident laser light

    Science.gov (United States)

    Sinclair; Michael B.; Sweatt, William C.

    2010-03-23

    A laser warning receiver is disclosed which has up to hundreds of individual optical channels each optically oriented to receive laser light from a different angle of arrival. Each optical channel has an optical wedge to define the angle of arrival, and a lens to focus the laser light onto a multi-wavelength photodetector for that channel. Each multi-wavelength photodetector has a number of semiconductor layers which are located in a multi-dielectric stack that concentrates the laser light into one of the semiconductor layers according to wavelength. An electrical signal from the multi-wavelength photodetector can be processed to determine both the angle of arrival and the wavelength of the laser light.

  11. SU-E-T-494: Influence of Proton Track-Cell Nucleus Incidence Angle On Relative Biological Effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Pater, P; Backstrom, G; Enger, S; Seuntjens, J; El Naqa, I [McGill University, Montreal, Quebec (Canada); Villegas, F; Ahnesjo, A [Uppsala University, Uppsala (Sweden)

    2015-06-15

    Purpose: To explain a Monte Carlo (MC) simulation artifact whereby differences in relative biological effectiveness (RBE) in the induction of initial double strand breaks are observed as a function of the proton track incidence angles in a geometric cell nucleus model. Secondly, to offer an alternative isotropic irradiation procedure to mitigate this effect. Methods: MC tracks of 1 MeV protons were generated in an event-by-event mode. They were overlaid on a cylindrical model of a cell nucleus containing 6×109 nucleotide base pairs. The tracks incidence angle θ with respect to the cell nucleus’s axis was varied in 10 degrees intervals, each time generating one hundred fractions of ∼2 Gy. Strand breaks were scored in the modeled DNA sugar-phosphate groups and further sub-classified into single or double strand breaks (ssbs or dsbs). For each angle, an RBE for the induction of initial dsbs with reference to Co-60 was calculated. Results: Our results show significant angular dependencies of RBE, with maximum values for incidence angles parallel to the nucleus central axis. Further examination shows that the higher cross-sections for the creation of dsbs is due to the preferential alignment of tracks with geometrical sub-parts of the cell nucleus model, especially the nucleosomes containing the sugar-phosphate groups. To alleviate the impact of this simulation artifact, an average RBE was calculated with a procedure based on a weighted sampling of the angular data. Conclusion: This work demonstrates a possible numerical artifact in estimated RBE if the influence of the particle incidence angle is not correctly taken into account. A correction procedure is presented to better conform the simulations to real-life experimental conditions. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and

  12. Grazing incidence small-angle neutron scattering-an advanced scattering technique for the investigation of nanostructured polymer films

    Science.gov (United States)

    Müller-Buschbaum, P.; Gutmann, J. S.; Cubitt, R.; Petry, W.

    2004-07-01

    With grazing incidence small-angle neutron scattering (GISANS), the limitations of conventional small-angle neutron scattering with respect to extremely small sample volumes in the thin-film geometry are overcome. GISANS turned out to be a powerful advanced scattering technique for the investigation of nanostructured polymer films. Similar to atomic force microscopy the surface topography is probed. In addition, buried structures from inside the film are detectable. As an example of the actual limits, nanostructures resulting from destabilized diblock copolymer films of poly(styrene-block-paramethylstyrene) in the highly confined regime are investigated. The stability of the structure, introduced by toluene vapor treatment, against annealing above the micro-phase separation temperature is shown.

  13. Grazing incidence small-angle neutron scattering - an advanced scattering technique for the investigation of nanostructured polymer films

    International Nuclear Information System (INIS)

    Mueller-Buschbaum, P.; Gutmann, J.S.; Cubitt, R.; Petry, W.

    2004-01-01

    With grazing incidence small-angle neutron scattering (GISANS), the limitations of conventional small-angle neutron scattering with respect to extremely small sample volumes in the thin-film geometry are overcome. GISANS turned out to be a powerful advanced scattering technique for the investigation of nanostructured polymer films. Similar to atomic force microscopy the surface topography is probed. In addition, buried structures from inside the film are detectable. As an example of the actual limits, nanostructures resulting from destabilized diblock copolymer films of poly(styrene-block-paramethylstyrene) in the highly confined regime are investigated. The stability of the structure, introduced by toluene vapor treatment, against annealing above the micro-phase separation temperature is shown

  14. Structure of polymer micelles close to the solid interface. A grazing incidence small angle neutron scattering study.

    Science.gov (United States)

    Wolff, M; Magerl, A; Zabel, H

    2005-02-01

    Block copolymers are widely used in industry. For scientific interests their aqueous solutions offer a model system for the investigation of crystallisation as the macromolecules agglomerate for elevated concentrations into micelles, which crystallise when a critical volume fraction is reached. We report on grazing incidence small angle neutron scattering (GISANS) or near surface small angle neutron scattering (NS-SANS) as an experimental tool to investigate the micelle crystallisation close to interfaces with different chemical termination. We find that in general crystallization is suppressed at a repulsive surface and favoured at an attractive one. Furthermore we show that the crystallization close the interface can be controlled by the micelle stability, resulting from the different composition and length of the monomers. The effect of the interface is found more important for a high micelle stability, whereas for a low stability it is shadowed by adsorbed monomers.

  15. Dependence of reflection and transmission of soliton on angle of incidence at an interface between chalcogenide fibre and gallium nanoparticle film by phase plane trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Naruka, Preeti, E-mail: preety-naruka@Yyahoo.co.in; Bissa, Shivangi [Deptt.of Physics, Engineering College Bikaner-334004, Rajasthan (India); Nagar, A. K. [Deptt. of Physics, Govt. Dungar College, Bikaner-334001, Rajasthan (India)

    2016-05-06

    In the present paper, we study propagation of a soliton at an interface formed between special type of chalcogenide fibre and gallium in three different phases with the help of equivalent particle theory. Critical angle of incidence and critical power required for transmission and reflection of soliton beam have investigated. Here it is found that if the incident angle of the beam or initial velocity of the equivalent particle is insufficient to overcome the maximum increase in potential energy then the particle (light beam) is reflected by the interface and if this incident angle is greater than a critical angle then light beam will be transmitted by the interface. From an equation these critical angles for α-gallium, one of a metastable phase and liquid gallium are calculated and concluded that at large incident angles, the soliton is transmitted through the boundary, whereas at small incidence angles the soliton get reflected on keeping the power of incident beam constant. These results are explained by phase plane trajectories of the effective potential which are experimentally as well as theoretically proved.

  16. Anomalous grazing incidence small-angle x-ray scattering studies of Pt nanoparticles formed by cluster deposition

    International Nuclear Information System (INIS)

    Lee, B.; Seifert, S.; Riley, S.J.; Tikhonov, G.Y.; Tomczyk, N.A.; Vajda, S.; Winans, R.E.

    2005-01-01

    The size evolution of platinum nanoparticles formed on a SiO2/Si(111) substrate as a function of the level of surface coverage with deposited clusters has been investigated. The anisotropic shapes of sub-nanometer-size nanoparticles are changed to isotropic on the amorphous substrate as their sizes increased. Using anomalous grazing incidence small-angle x-ray scattering (AGISAXS), the scattering from nanoparticles on the surface of a substrate is well separated from that of surface roughness and fluorescence. We show that AGISAXS is a very effective method to subtract the background and can provide unbiased information about particle sizes of less than 1 nm.

  17. Wideband metamaterial array with polarization-independent and wide incident angle for harvesting ambient electromagnetic energy and wireless power transfer

    Science.gov (United States)

    Zhong, Hui-Teng; Yang, Xue-Xia; Song, Xing-Tang; Guo, Zhen-Yue; Yu, Fan

    2017-11-01

    In this work, we introduced the design, demonstration, and discussion of a wideband metamaterial array with polarization-independent and wide-angle for harvesting ambient electromagnetic (EM) energy and wireless power transfer. The array consists of unit cells with one square ring and four metal bars. In comparison to the published metamaterial arrays for harvesting EM energy or wireless transfer, this design had the wide operation bandwidth with the HPBW (Half Power Band Width) of 110% (6.2 GHz-21.4 GHz), which overcomes the narrow-band operation induced by the resonance characteristic of the metamaterial. On the normal incidence, the simulated maximum harvesting efficiency was 96% and the HPBW was 110% for the random polarization wave. As the incident angle increases to 45°, the maximum efficiency remained higher than 88% and the HPBW remained higher than 83% for the random polarization wave. Furthermore, the experimental verification of the designed metamaterial array was conducted, and the measured results were in reasonable agreement with the simulated ones.

  18. Investigation and modeling of the effects of light spectrum and incident angle on the growth of Chlorella vulgaris in photobioreactors.

    Science.gov (United States)

    Souliès, Antoine; Legrand, Jack; Marec, Hélène; Pruvost, Jérémy; Castelain, Cathy; Burghelea, Teodor; Cornet, Jean-François

    2016-03-01

    An in-depth investigation of how various illumination conditions influence microalgal growth in photobioreactors (PBR) has been presented. Effects of both the light emission spectrum (white and red) and the light incident angle (0° and 60°) on the PBR surface were investigated. The experiments were conducted in two fully controlled lab-scale PBRs, a torus PBR and a thin flat-panel PBR for high cell density culture. The results obtained in the torus PBR were used to build the kinetic growth model of Chlorella vulgaris taken as a model species. The PBR model was then applied to the thin flat-panel PBR, which was run with various illumination conditions. Its detailed representation of local rate of photon absorption under various conditions (spectral calculation of light attenuation, incident angle influence) enabled the model to take into account all the tested conditions with no further adjustment. This allowed a detailed investigation of the coupling between radiation field and photosynthetic growth. Effects of all the radiation conditions together with pigment acclimation, which was found to be relevant, were investigated in depth. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:247-261, 2016. © 2016 American Institute of Chemical Engineers.

  19. Stress measurements by multi-reflection grazing-incidence X-ray diffraction method (MGIXD) using different radiation wavelengths and different incident angles

    International Nuclear Information System (INIS)

    Marciszko, Marianna; Baczmański, Andrzej; Braham, Chedly; Wróbel, Mirosław; Wroński, Sebastian; Cios, Grzegorz

    2017-01-01

    The presented study introduces the development of the multi-reflection grazing-incidence X-ray diffraction method (MGIXD) for residual stress determination. The proposed new methodology is aimed at obtaining more reliable experimental data and increasing the depth of non-destructive stress determination below the sample surface. To verify proposed method measurements were performed on a classical X-ray diffractometer (Cu Kα radiation) and using synchrotron radiation (three different wavelengths: λ = 1.2527 Å, λ = 1.5419 Å and λ = 1.7512 Å). The Al2017 alloy subjected to three different surface treatments was investigated in this study. The obtained results showed that the proposed development of MGIXD method, in which not only different incident angles but also different wavelengths of X-ray are used, can be successfully applied for residual stress determination, especially when stress gradients are present in the sample.

  20. Modifying the hip abduction angle during bridging exercise can facilitate gluteus maximus activity.

    Science.gov (United States)

    Kang, Sun-Young; Choung, Sung-Dae; Jeon, Hye-Seon

    2016-04-01

    To investigate how the erector spinae (ES) and gluteus maximus (GM) muscle activity and the anterior pelvic tilt angle change with different hip abduction angles during a bridging exercise. Twenty healthy participants (10 males and 10 females, aged 21.6 ± 1.6) voluntarily participated in this study. Surface electromyography (EMG) signals were recorded from the ES and GM during bridging at three hip abduction angles: 0°, 15°, and 30°. Simultaneously, the anterior pelvic tilt angle was measured using Image J software. The EMG amplitude of the GM muscle and the GM/ES EMG ratio were greatest at 30° hip abduction, followed by 15° and then 0° hip abduction during the bridging exercise. In contrast, the ES EMG amplitude at 30° hip abduction was significantly lesser than that at 0° and 15° abduction. Additionally, the anterior pelvic tilt angle was significantly lower at 30° hip abduction than at 0° or 15°. Bridging with 30° hip abduction can be recommended as an effective method to selectively facilitate GM muscle activity, minimize compensatory ES muscle activity, and decrease the anterior pelvic tilt angle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Dimensional nanometrology with grazing incidence small angle X-ray scattering (GISAXS)

    Energy Technology Data Exchange (ETDEWEB)

    Wernecke, Jan; Krumrey, Michael; Cibik, Levent; Marggraf, Stefanie; Mueller, Peter [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany)

    2011-07-01

    Reliable methods for dimensional characterisation of structures in the nanometer range are now a necessity in many fields of industry and science, e.g. for next-generation EUV lithography, new photovoltaic devices or magnetic nanoparticles. The method we have chosen for measurements of statistically averaged structural properties of nanostructured surfaces is GISAXS. This is a versatile technique to probe statistic properties such as mean particle size, spacial distribution and roughness of nanostructured surfaces and nanoparticle assemblies on top of or buried in bulk material. The GISAXS experiments were performed at the Four-Crystal Monochromator (FCM) beamline in the laboratory of PTB at BESSY II using the SAXS setup of the Helmholtz-Zentrum Berlin (HZB). This presentation will give a short overview of the instrumentation and the capabilities of the laboratory to perform dimensional nanometrology with GISAXS and will show first experimental results. Gratings for EUV lithography have been investigated in terms of coating layer thickness, roughness, grating period and blaze angle. Furthermore, dimensional properties of Au nanoparticles on silicon substrate were determined. The obtained particle sizes were in good agreement with SAXS measurements of these particles in liquid suspension.

  2. Investigating the impact of noise incidence angle on the sound insulation of a supply air window

    DEFF Research Database (Denmark)

    Hansen, Morten B.; Tambo, Torben

    2015-01-01

    The Danish Environmental Agency introduced in 2007 a guideline “Noise from roads”, in which noise limits for open windows were introduced. This guideline has led to investigations of open windows with good sound insulation, and among one of these windows are the “Supply Air Window”. Prior sound i...... in the receiving room ceiling, have been simulated and show a general improvement of the sound reduction index from 500 Hz and above, and an improvement of ~3-4 dB at 2 kHz, in relation to the noise angle ofindidence.......The Danish Environmental Agency introduced in 2007 a guideline “Noise from roads”, in which noise limits for open windows were introduced. This guideline has led to investigations of open windows with good sound insulation, and among one of these windows are the “Supply Air Window”. Prior sound...... insulation measurements of the Supply Air Window show a difference in the frequency range above 2 kHz, for field measurements carried out according to EN ISO 140-5 and laboratory measurements carried out according to EN ISO 10140-2. It is found that the sound insulation measured in the field setup...

  3. Side-pumped Nd:YVO4 cw laser with grazing-incidence small angle configuration

    International Nuclear Information System (INIS)

    Camargo, Fabiola de Almeida

    2006-01-01

    Within the existing variety of laser cavity geometries and gain materials there is one combination that is particularly interesting because of its reduced complexity and high efficiency: the edge-pumped slab-laser using grazing-incidence geometry and a gain media with a very high pump absorption cross-section. In this work we studied a diode side-pumped Nd:YVO 4 cw laser. We describe a single and a multiple bounce laser configurations. We demonstrate 22 W of multimode output power for 35 watts of pump power with a single pass through the gain media. A high optical-to-optical conversion efficiency of 63% and a slope efficiency of 74% with a very compact and simple Nd:YVO 4 cavity that uses joint stability zones was achieved. The beam quality was M 2 = 26 x 11 in the horizontal and vertical direction, respectively. With a double pass configuration we achieved 17 watts with a better beam quality of M 2 = 3,4 x 3,7, in the horizontal and vertical direction, respectively. (author)

  4. The hospital incident command system: modified model for hospitals in iran.

    Science.gov (United States)

    Djalali, Ahmadreza; Hosseinijenab, Vahid; Peyravi, Mahmoudreza; Nekoei-Moghadam, Mahmood; Hosseini, Bashir; Schoenthal, Lisa; Koenig, Kristi L

    2015-03-27

    Effectiveness of hospital management of disasters requires a well-defined and rehearsed system. The Hospital Incident Command System (HICS), as a standardized method for command and control, was established in Iranian hospitals, but it has performed fairly during disaster exercises. This paper describes the process for, and modifications to HICS undertaken to optimize disaster management in hospitals in Iran. In 2013, a group of 11 subject matter experts participated in an expert consensus modified Delphi to develop modifications to the 2006 version of HICS. The following changes were recommended by the expert panel and subsequently implemented: 1) A Quality Control Officer was added to the Command group; 2) Security was defined as a new section; 3) Infrastructure and Business Continuity Branches were moved from the Operations Section to the Logistics and the Administration Sections, respectively; and 4) the Planning Section was merged within the Finance/Administration Section. An expert consensus group developed a modified HICS that is more feasible to implement given the managerial organization of hospitals in Iran. This new model may enhance hospital performance in managing disasters. Additional studies are needed to test the feasibility and efficacy of the modified HICS in Iran, both during simulations and actual disasters. This process may be a useful model for other countries desiring to improve disaster incident management systems for their hospitals.

  5. Grazing Incidence angle X-ray Diffraction of implanted stainless steel: comparison between simulated data and experimental data

    International Nuclear Information System (INIS)

    Dudognon, J.; Vayer, M.; Pineau, A.; Erre, R.

    2006-01-01

    Austenitic stainless steel was implanted with specific elements using specific conditions. The goal of this studies was to compare the predicted structural modifications within the implanted layer with the experimental ones observed by Grazing Incidence angle X-ray Diffraction (GIXD).During ion implantation implanted austenite steel layer undergoes modifications such as austenite lattice expansion, ferrite apparition and structure destruction. The X-ray diffraction austenite peak shape was predicted using the concentration depth profile of implanted element, the information depth profile of diffracted intensity and a linear relationship between implanted element concentration and lattice parameter. Experimental and predicted austenite X-ray diffraction peaks are in good accordance as long as the implanted layer contents mainly austenite. Whatever the nature of implanted element, ferrite appears above a given threshold of incoming energy amount. Moreover, the structure of the implanted layer is destroyed above a given amount of incoming energy

  6. Depth profile characterization of electrodeposited multi-thin-film structures by low angle of incidence X-ray diffractometry

    International Nuclear Information System (INIS)

    Nauer, M.; Ernst, K.; Kautek, W.; Neumann-Spallart, M.

    2005-01-01

    Typical structures of heterojunction photovoltaic cells were prepared by sequential electrodeposition of II-VI semiconductor thin films on a transparent conductor, SnO 2 on glass. The structures comprised a wide bandgap window, ZnSe or ZnTe, a medium bandgap light absorber, CdTe, and an ohmic back contact. It is demonstrated that low incidence angle X-ray diffraction (LIXD) can be successfully used as a process monitoring tool, featuring non-destructive depth profiling and phase characterization of such thin film structures. LIXD results are compared to Secondary Ion Mass Spectroscopy (SIMS) and Scanning Electron Microscopy (SEM) data. Both, SIMS and SEM, corroborate the LIXD results as to layer sequence and presence/absence of intermixing

  7. Time of flight grazing incidence small angle neutron scattering. A novel scattering technique for the investigation of nanostructured polymer films

    Science.gov (United States)

    Müller-Buschbaum, P.; Metwalli, E.; Moulin, J.-F.; Kudryashov, V.; Haese-Seiller, M.; Kampmann, R.

    2009-02-01

    Grazing incidence small angle neutron scattering (GISANS) overcomes the limitations of conventional small angle scattering with respect to extremely small sample volumes in the thin film geometry. In time of flight (TOF) mode neutrons with a broad range of wavelengths are used simultaneously and recorded as a function of their respective times of flight. The combination of both, TOF-GISANS, enables the simultaneous performance of several GISANS measurements, which differ in wavelength. As a consequence, within one measurement a full set of GISANS pattern related to different scattering vectors, different scattering depths and resolutions result. This allows the detection of nanostructures with a chemical sensitivity. The possibilities of TOF-GISANS are demonstrated by the simple example of polymer nano-dots located on top of a silicon surface. As probed with atomic force microscopy (AFM) the nano-dots exhibit a large characteristic nearest neighbour distance of 545 nm and a surface coverage of 28%. From the analysis of the wavelength dependent data in combination with AFM the mass density of the polymer nano-dots is determined to be equal to the bulk value. A comparison to common single wavelength GISANS experiments is shown.

  8. Reduction of the divergence angle of an incident beam to enhance the demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system of several tens of keV

    Science.gov (United States)

    Ishii, Yasuyuki; Kojima, Takuji

    2018-04-01

    The demagnification factor of a two-stage acceleration lens in a gas ion nanobeam system that produces ion beams with energies in the order of 10 keV was enhanced in this study so that a hydrogen ion beam with a diameter of 115 nm could be produced. The reduction of the divergence angle of the incident beam into the two-stage acceleration lens is the effective method for enhancing the demagnification factor. The divergence angle has been gradually reduced by firstly introducing the preacceleration electrodes to control the divergence angle, namely divergence-angle-control electrodes, and secondly replacing an anode with a modified anode that possesses a Pierce electrode, both of which were in an ion source directly connected to the lens. In this study, the divergence angle of less than 3.6 × 10-4 rad that was previously used to produce a 160-nm hydrogen ion beam with the energy of 46 keV by the above procedure was numerically determined using an ion beam extraction simulation code. The determined minimum divergence angle of the incident ion beam was calculated to be 2.0 × 10-4 rad, which was about half of the previously obtained divergence angle; this was used to experimentally form a hydrogen beam with a diameter of 115 ± 10 nm and the energy of 47 keV. The demagnification factor was estimated to be 1,739 using the newly formed hydrogen beam, which was similar to the simulation result.

  9. Dependence of secondary electron emission on the incident angle and the energy of primary electrons bombarding bowl-structured beryllium surfaces

    International Nuclear Information System (INIS)

    Kawata, Jun; Ohya, Kaoru.

    1994-01-01

    A Monte Carlo simulation of the secondary electron emission from beryllium is combined with a model of bowl structure for surface roughness, for analyzing the difference between the electron emissions for normal and oblique incidences. At normal incidence, with increasing the roughness parameter H/W, the primary energy E pm at which the maximum electron yield occurs becomes higher, and at more than the E pm , the decrease in the yield is slower; where H and W are the depth and width of the bowl structure, respectively. The dispersion of incident angle to the microscopic surface causes a small increase in the yield at oblique incidence, whereas the blocking of primary electrons from bombarding the bottom of the structure causes an opposite trend. The strong anisotropy in the polar angular distribution with respect to the azimuthal angle is calculated at oblique incidence. (author)

  10. Incidence Angle Effect of Energetic Carbon Ions on Deposition Rate, Topography, and Structure of Ultrathin Amorphous Carbon Films Deposited by Filtered Cathodic Vacuum Arc

    KAUST Repository

    Wang, N.

    2012-07-01

    The effect of the incidence angle of energetic carbon ions on the thickness, topography, and structure of ultrathin amorphous carbon (a-C) films synthesized by filtered cathodic vacuum arc (FCVA) was examined in the context of numerical and experimental results. The thickness of a-C films deposited at different incidence angles was investigated in the light of Monte Carlo simulations, and the calculated depth profiles were compared with those obtained from high-resolution transmission electron microscopy (TEM). The topography and structure of the a-C films were studied by atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS), respectively. The film thickness decreased with the increase of the incidence angle, while the surface roughness increased and the content of tetrahedral carbon hybridization (sp 3) decreased significantly with the increase of the incidence angle above 45° , measured from the surface normal. TEM, AFM, and XPS results indicate that the smoothest and thinnest a-C films with the highest content of sp 3 carbon bonding were produced for an incidence angle of 45°. The findings of this study have direct implications in ultrahigh-density magnetic recording, where ultrathin and smooth a-C films with high sp 3 contents are of critical importance. © 2012 IEEE.

  11. Angular CMA: A modified Constant Modulus Algorithm providing steering angle updates

    NARCIS (Netherlands)

    Blom, K.C.H.; van de Burgwal, M.D.; Rovers, K.C.; Kokkeler, Andre B.J.; Smit, Gerardus Johannes Maria

    2011-01-01

    Conventional blind beamforming algorithms have no direct notion of the physical Direction of Arrival angle of an impinging signal. These blind adaptive algorithms operate by adjusting the complex steering vector in the case of changing signal conditions and directions. This paper presents Angular

  12. Modifying Post-Operative Medical Care after EBV Implant May Reduce Pneumothorax Incidence.

    Directory of Open Access Journals (Sweden)

    Dominik Herzog

    Full Text Available Endoscopic lung volume reduction (ELVR with valves has been shown to improve COPD patients with severe emphysema. However, a major complication is pneumothoraces, occurring typically soon after valve implantation, with severe consequences if not managed promptly. Based on the knowledge that strain activity is related to a higher risk of pneumothoraces, we asked whether modifying post-operative medical care with the inclusion of strict short-term limitation of strain activity is associated with a lower incidence of pneumothorax.Seventy-two (72 emphysematous patients without collateral ventilation were treated with bronchial valves and included in the study. Thirty-two (32 patients received standard post-implantation medical management (Standard Medical Care (SMC, and 40 patients received a modified medical care that included an additional bed rest for 48 hours and cough suppression, as needed (Modified Medical Care (MMC.The baseline characteristics were similar for the two groups, except there were more males in the SMC cohort. Overall, ten pneumothoraces occurred up to four days after ELVR, eight pneumothoraces in the SMC, and only two in the MMC cohorts (p=0.02. Complicated pneumothoraces and pneumothoraces after upper lobe treatment were significantly lower in MMC (p=0.02. Major clinical outcomes showed no significant differences between the two cohorts.In conclusion, modifying post-operative medical care to include bed rest for 48 hours after ELVR and cough suppression, if needed, might reduce the incidence of pneumothoraces. Prospective randomized studies with larger numbers of well-matched patients are needed to confirm the data.

  13. Slurry Erosion Studies on Surface Modified 13Cr-4Ni Steels: Effect of Angle of Impingement and Particle Size

    Science.gov (United States)

    Manisekaran, T.; Kamaraj, M.; Sharrif, S. M.; Joshi, S. V.

    2007-10-01

    Hydroturbine steels, such as 13Cr-4Ni martensitic steels, are generally subjected to heavy-erosive wear and loss of efficiency due to solid particulate entrainment in the water. Surface-modified steels have proven to give better performance in terms of erosive wear resistance. In the present study, an attempt is made to investigate the effect of angle of impingement and particle size on slurry-jet erosion behavior of pulsed plasma nitrided and laser hardened 13Cr-4Ni steels. Laser hardening process has shown good performance at all angles of impingement due to martensitic transformation of retained austenite. Plastic deformation mode of material removal was also an evident feature of all laser-hardened surface damage locations. However, pulsed-plasma nitrided steels have exhibited chip formation and micro-cutting mode of erosive wear. Erosion with 150-300 μm size was twice compared to 150 μm size slurry particulates.

  14. Modified bisecting angle technique in eliminating zygomatic superimposition over apices of maxillary molars

    OpenAIRE

    Anshuman S Jamdade

    2014-01-01

    Background: Image superimposition is a part and parcel of two-dimensional radiography. However, some overlappings are a result of radiographic technique itself. The technique induced superimposition of zygomatic buttress on apices of maxillary molars is common in bisecting angle technique (BAT), which affects the endodontic performance. Certain alterations were carried out in BAT to remove these undiagnostic shadows. The aim of this study was to compare two techniques of periapical radiograph...

  15. Wide Angle of Incidence-Insensitive Polarization-Independent THz Metamaterial Absorber for Both TE and TM Mode Based on Plasmon Hybridizations

    Directory of Open Access Journals (Sweden)

    Xiu Tao Huang

    2018-04-01

    Full Text Available An ultra-wide-angle THz metamaterial absorber (MA utilizing sixteen-circular-sector (SCR resonator for both transverse electric (TE and transverse magnetic (TM mode is designed and investigated numerically. At normal incidence, the absorptivity of the proposed MA is higher than 93.7% at 9.05 THz for different polarization angles, due to the rotational symmetry structure of the unit cell. Under oblique incidence, the absorptivity can still exceed 90%, even when the incident angle is up to 70° for both TE and TM mode. Especially, the frequency variation in TE mode is less than 0.25% for different incident angles from 0° to 70°. The electric field (Ez distributions are used to explain the absorption mechanism. Numerical simulation results show that the high absorption with wide-angle independence stems from fundamental dipole resonance and gap surface plasmons. The broadband deep-infrared MA is also obtained by stacking three metal-dielectric layers. The designed MA has great potential in bolometric pixel elements, biomedical sensors, THz imaging, and solar cells.

  16. Optimal design and fabrication method for antireflection coatings for P-polarized 193 nm laser beam at large angles of incidence (68°-74°).

    Science.gov (United States)

    Jin, Jingcheng; Jin, Chunshui; Li, Chun; Deng, Wenyuan; Chang, Yanhe

    2013-09-01

    Most of the optical axes in modern systems are bent for optomechanical considerations. Antireflection (AR) coatings for polarized light at oblique incidence are widely used in optical surfaces like prisms or multiform lenses to suppress undesirable reflections. The optimal design and fabrication method for AR coatings with large-angle range (68°-74°) for a P-polarized 193 nm laser beam is discussed in detail. Experimental results showed that after coating, the reflection loss of a P-polarized laser beam at large angles of incidence on the optical surfaces is reduced dramatically, which could greatly improve the output efficiency of the optical components in the deep ultraviolet vacuum range.

  17. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities

    International Nuclear Information System (INIS)

    Fondevila, Damian; Arbiser, Silvio; Sansogne, Rosana; Brunetto, Monica; Dosoretz, Bernardo

    2008-01-01

    Primary barrier determinations for the shielding of medical radiation therapy facilities are generally made assuming normal beam incidence on the barrier, since this is geometrically the most unfavorable condition for that shielding barrier whenever the occupation line is allowed to run along the barrier. However, when the occupation line (for example, the wall of an adjacent building) runs perpendicular to the barrier (especially roof barrier), then two opposing factors come in to play: increasing obliquity angle with respect to the barrier increases the attenuation, while the distance to the calculation point decreases, hence, increasing the dose. As a result, there exists an angle (α max ) for which the equivalent dose results in a maximum, constituting the most unfavorable geometric condition for that shielding barrier. Based on the usual NCRP Report No. 151 model, this article presents a simple formula for obtaining α max , which is a function of the thickness of the barrier (t E ) and the equilibrium tenth-value layer (TVL e ) of the shielding material for the nominal energy of the beam. It can be seen that α max increases for increasing TVL e (hence, beam energy) and decreases for increasing t E , with a range of variation that goes from 13 to 40 deg for concrete barriers thicknesses in the range of 50-300 cm and most commercially available teletherapy machines. This parameter has not been calculated in the existing literature for radiotherapy facilities design and has practical applications, as in calculating the required unoccupied roof shielding for the protection of a nearby building located in the plane of the primary beam rotation

  18. Comparison of large-angle production of charged pions with incident protons on cylindrical long and short targets

    CERN Document Server

    Apollonio, M.; Bagulya, A.; Barr, G.; Blondel, A.; Bobisut, F.; Bogomilov, M.; Bonesini, M.; Booth, C.; Borghi, S.; Bunyatov, S.; Burguet-Castell, J.; Catanesi, M.G.; Cervera-Villanueva, A.; Chimenti, P.; Coney, L.; Di Capua, E.; Dore, U.; Dumarchez, J.; Edgecock, R.; Ellis, M.; Ferri, F.; Gastaldi, U.; Giani, S.; Giannini, G.; Gibin, D.; Gilardoni, S.; Gorbunov, P.; Gossling, C.; Gomez-Cadenas, J.J.; Grant, A.; Graulich, J.S.; Gregoire, G.; Grichine, V.; Grossheim, A.; Guglielmi, A.; Howlett, L.; Ivanchenko, A.; Ivanchenko, V.; Kayis-Topaksu, A.; Kirsanov, M.; Kolev, D.; Krasnoperov, A.; Martin-Albo, J.; Meurer, C.; Mezzetto, M.; Mills, G.B.; Morone, M.C.; Novella, P.; Orestano, D.; Palladino, V.; Panman, J.; Papadopoulos, I.; Pastore, F.; Piperov, Stefan; Polukhina, N.; Popov, B.; Prior, G.; Radicioni, E.; Schmitz, D.; Schroeter, R.; Skoro, G; Sorel, M.; Tcherniaev, E.; Temnikov, P.; Tereschenko, V.; Tonazzo, A.; Tortora, L.; Tsenov, R.; Tsukerman, I.; Vidal-Sitjes, G.; Wiebusch, C.; Zucchelli, P.

    2009-01-01

    The HARP collaboration has presented measurements of the double-differential pi+/pi- production cross-section in the range of momentum 100 MeV/c <= p 800 MeV/c and angle 0.35 rad <= theta <= 2.15 rad with proton beams hitting thin nuclear targets. In many applications the extrapolation to long targets is necessary. In this paper the analysis of data taken with long (one interaction length) solid cylindrical targets made of carbon, tantalum and lead is presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN PS. The secondary pions were produced by beams of protons with momenta 5 GeV/c, 8 GeV/c and 12 GeV/c. The tracking and identification of the produced particles were performed using a small-radius cylindrical time projection chamber (TPC) placed inside a solenoidal magnet. Incident protons were identified by an elaborate system of beam detectors. Results are obtained for the double-differential yields per target nucleon d2 sigma / dp dtheta. The measure...

  19. Diagnosis of secondary caries in esthetic restorations: influence of the incidence vertical angle of the X-ray beam.

    Science.gov (United States)

    Moreira, Patrícia Lima; Messora, Michel Reis; Pereira, Stela Márcia; Almeida, Solange Maria de; Cruz, Adriana Dibo da

    2011-01-01

    The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (A(z)), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (A(z)=0.66, Filtek-Z250>A(z)=0.56, TPH-Spectrum) compared to 0º (A(z)=0.55, Charisma>A(z)=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.

  20. Modified Vertical Bearing Capacity for Circular Foundations in Sand Using Reduced Friction Angle

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Barari, Amin; Larsen, Kim André

    2012-01-01

    Recently Bucket foundation as a large cylindrical structure that is open as the base and closed at the top, has attracted much attention in offshore projects. In order to present relationship between vertical bearing capacity of a bucket foundation relative to the corresponding capacity of a circ......Recently Bucket foundation as a large cylindrical structure that is open as the base and closed at the top, has attracted much attention in offshore projects. In order to present relationship between vertical bearing capacity of a bucket foundation relative to the corresponding capacity...... of a circular plate, several loading tests on small scale bucket foundations including the circular surface footings are performed at Aalborg University. In current research, the vertical bearing capacity of circular surface footings is investigated using reduced friction angle. It is also presented a linear...

  1. Investigation of photon detection probability dependence of SPADnet-I digital photon counter as a function of angle of incidence, wavelength and polarization

    Energy Technology Data Exchange (ETDEWEB)

    Játékos, Balázs, E-mail: jatekosb@eik.bme.hu; Ujhelyi, Ferenc; Lőrincz, Emőke; Erdei, Gábor

    2015-01-01

    SPADnet-I is a prototype, fully digital, high spatial and temporal resolution silicon photon counter, based on standard CMOS imaging technology, developed by the SPADnet consortium. Being a novel device, the exact dependence of photon detection probability (PDP) of SPADnet-I was not known as a function of angle of incidence, wavelength and polarization of the incident light. Our targeted application area of this sensor is next generation PET detector modules, where they will be used along with LYSO:Ce scintillators. Hence, we performed an extended investigation of PDP in a wide range of angle of incidence (0° to 80°), concentrating onto a 60 nm broad wavelength interval around the characteristic emission peak (λ=420 nm) of the scintillator. In the case where the sensor was optically coupled to a scintillator, our experiments showed a notable dependence of PDP on angle, polarization and wavelength. The sensor has an average PDP of approximately 30% from 0° to 60° angle of incidence, where it starts to drop rapidly. The PDP turned out not to be polarization dependent below 30°. If the sensor is used without a scintillator (i.e. the light source is in air), the polarization dependence is much less expressed, it begins only from 50°.

  2. Inner Stucture of Thin Films of Lamellar Poly(styrene-b-butadiene) Diblock Copolymers as revealed by Grazing-Incidence Small-Angle Scattering

    DEFF Research Database (Denmark)

    Busch, Peter; Posselt, Dorthe; Smilgies, Detlef-Matthias

    2007-01-01

    The lamellar orientation in supported, thin films of poly(styrene-b-butadiene) (P(S-b-B)) depends on block copolymer molar mass. We have studied films from nine block copolymer samples with molar masses between 13.9 and 183 kg/mol using grazing-incidence small-angle X-ray scattering (GISAXS...

  3. Relationship between Pelvic Incidence Angle and Blood Concentration of Chromium and Cobalt Ions after Metal-on-Metal Hip Replacement: A Brief Report.

    Science.gov (United States)

    Pernaa, K; Saltychev, M; Mäkelä, K

    2018-03-01

    The wear of metal-on-metal hip implants may increase chromium or cobalt ion blood level. This phenomenon may depend among other things on the particularity of spinopelvic anatomy. The effect of pelvic incidence angle on the wear of metal-on-metal hip implants is not known. The objective of the study was to investigate whether such effect does exist. The pelvic incidence and inclination of acetabular component angles of 89 patients after unilateral metal-on-metal hip replacement were compared with blood level of chromium and cobalt ions using Pearson correlation coefficient. No significant correlations between pelvic incidence angle and the metal ion blood levels were observed. The correlation coefficients varied from -0.02 to 0.2 and all p values were >0.05. No evidence was found on the effect of pelvic incidence angle on metal wear after metal-on-metal hip replacement when measured by the blood levels of chromium and cobalt ions. It is reasonable to assume that other factors than pelvic tilt may affect the rate of implant wear.

  4. Major incident triage: Derivation and comparative analysis of the Modified Physiological Triage Tool (MPTT).

    Science.gov (United States)

    Vassallo, James; Beavis, John; Smith, Jason E; Wallis, Lee A

    2017-05-01

    Triage is a key principle in the effective management at a major incident. There are at least three different triage systems in use worldwide and previous attempts to validate them, have revealed limited sensitivity. Within a civilian adult population, there has been no work to develop an improved system. A retrospective database review of the UK Joint Theatre Trauma Registry was performed for all adult patients (>18years) presenting to a deployed Military Treatment Facility between 2006 and 2013. Patients were defined as Priority One if they had received one or more life-saving interventions from a previously defined list. Using first recorded hospital physiological data (HR/RR/GCS), binary logistic regression models were used to derive optimum physiological ranges to predict need for life-saving intervention. This allowed for the derivation of the Modified Physiological Triage Tool-MPTT (GCS≥14, HR≥100, 12triage tools was then performed using sensitivities and specificities with 95% confidence intervals. Differences in performance were assessed for statistical significance using a McNemar test with Bonferroni correction. Of 6095 patients, 3654 (60.0%) had complete data and were included in the study, with 1738 (47.6%) identified as priority one. Existing triage tools had a maximum sensitivity of 50.9% (Modified Military Sieve) and specificity of 98.4% (Careflight). The MPTT (sensitivity 69.9%, 95% CI 0.677-0.720, specificity 65.3%, 95% CI 0.632-0.675) showed an absolute increase in sensitivity over existing tools ranging from 19.0% (Modified Military Sieve) to 45.1% (Triage Sieve). There was a statistically significant difference between the performance (ptriage systems, whilst maintaining an appropriate rate of over-triage and minimising under-triage within the context of predicting the need for a life-saving intervention in a military setting. Further work is required to both prospectively validate this system and to identify its performance within a

  5. The efficacy of modified non-penetrating deep sclerectomy in open-angle glaucoma treatment

    Directory of Open Access Journals (Sweden)

    E. A. Ivachev

    2015-01-01

    Full Text Available Aim. To analyze the efficacy of modified non-penetrating deep sclerectomy. Materials and methods. POAG patients enrolled in the study were divided into 2 groups: study group included 29 patients who were referred for modified non-penetrating deep sclerectomy, control group included 33 patients who were referred for standard non-penetrating deep sclerectomy. IOP level was 31.9±3.2 mm Hg in the study group and 31.5±3.3 mm Hg in the control group. Modification of non-penetrating deep sclerectomy consists in the separation of fornix-based Ushaped scleral flap, Schlemm’s canal opening, scleral tunnel creation and its dilation with polyamide 5/0 suture. Results. Three weeks after surgery, moderate hypotension was observed in both groups (15.7±1.56 mm Hg in the study group and 16.9±1.9 in the control group. Three months after surgery, IOP level was 17.47±1.24 mm Hg in the study group and 18.74±1.37 in the control group. Ten months after surgery, IOP level in the study group was significantly lower than in the control group (19.14±1.27 mm Hg and 21.31±1.42 mm Hg, respectively, р<0.05. Conclusions. The proposed surgical technique provides stable and long-term hypotensive effect and prevents excessive scarring in filtering area. Suture inserted into the scleral tunnel dilates it and provides continuous aqueous humor outflow. 

  6. Turn-on Angle Control Using Modified Torque Sharing Function for Torque Ripple Reduction in Switched Reluctance Motors

    Directory of Open Access Journals (Sweden)

    Mehrdad Daryanush

    2015-07-01

    Full Text Available In the recent years, the use of switched reluctance motors (SRM in industrial applications has been increased. In this regard, a large amount of research studies have been conducted on controlling the speed and torque of the aforementioned motors. These motors not only have a simple and stable structure, but also production cost is low. In addition, these motors take advantage of great power, the ability to work in high speeds and inadequate environments (hot and dusty, reliability, control-ability, and high efficiency. However, discrete torque production of SRM along with enormous magnetic saturation in their cores reduces the variety of their industrial applications and also causes the inappropriate torque ripples. In this paper, a modified logical-rule-based method is proposed which employs the technique of controlling torque sharing function. Moreover, the optimized turn-on angle for conducting each phase is achieved by estimating the inductance curve in the vicinity of unaligned position and based on an analytical solution. Simulation results on a four-phase switched reluctance motor and a comparison with the conventional methods indicates validity and effectiveness of the proposed modified method.

  7. Modified Hitschfeld-Bordan Equations for Attenuation-Corrected Radar Rain Reflectivity: Application to Nonuniform Beamfilling at Off-Nadir Incidence

    Science.gov (United States)

    Meneghini, Robert; Liao, Liang

    2013-01-01

    As shown by Takahashi et al., multiple path attenuation estimates over the field of view of an airborne or spaceborne weather radar are feasible for off-nadir incidence angles. This follows from the fact that the surface reference technique, which provides path attenuation estimates, can be applied to each radar range gate that intersects the surface. This study builds on this result by showing that three of the modified Hitschfeld-Bordan estimates for the attenuation-corrected radar reflectivity factor can be generalized to the case where multiple path attenuation estimates are available, thereby providing a correction to the effects of nonuniform beamfilling. A simple simulation is presented showing some strengths and weaknesses of the approach.

  8. Depth profiling study of in situ CdCl{sub 2} treated CdTe/CdS heterostructure with glancing angle incidence X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Vamsi Krishna, K.; Dutta, V

    2004-03-01

    CdTe thin films have been deposited using spray pyrolysis technique without and with in situ CdCl{sub 2} treatment. Scanning electron microscopy studies show enhanced grain growth in the presence of CdCl{sub 2}. Glancing angle incidence X-ray diffraction is used for the micro structural study of polycrystalline CdS/CdTe heterostructure at different depths by changing the incident angle. Spraying of CdCl{sub 2} on CdS prior to CdTe deposition promotes S diffusion throughout CdTe film and also Te diffusion into CdS. Whereas spraying of CdCl{sub 2} in between CdTe deposition prevents S diffusion partially and Te diffusion completely. There is an associated change in the microstress of the CdTe film at different layers. The films without CdCl{sub 2} treatment show compressive microstress varying from -98 to -158 MPa with increasing incident angle. CdCl{sub 2} spray during CdTe deposition shows compressive microstress, which varies from -98 MPa at the interface to -19 MPa near the surface and CdCl{sub 2} spray prior to CdTe deposition leads to a mildly tensile stress, from +40 to +20 MPa, which is very close to the standard shear stress of {approx}10 MPa for CdTe.

  9. Bare and thin-film-coated substrates with null reflection for p- and s-polarized light at the same angle of incidence: reflectance and ellipsometric parameters as functions of substrate refractive index and film thickness.

    Science.gov (United States)

    Azzam, R M A

    2016-10-20

    Intensity reflectances and ellipsometric parameters of a partially clad transparent substrate that suppresses the reflection of incident p- and s-polarized light at the same angle of incidence from uncoated and single-layer-coated areas are determined as functions of normalized film thickness ς and substrate refractive index n2. The common polarizing angle is the Brewster angle of the ambient-substrate interface, and the light beam incident from the ambient (air or vacuum) is refracted in the film at a 45° angle from the normal to the parallel-plane film boundaries. For n2≤2, the differential reflection phase shift Δ=δp-δs≈±90° for all values of ς so that the Brewster angle is also approximately the principal angle of the film-substrate system independent of film thickness. Accurate techniques for monitoring the deposition of such films are also proposed.

  10. Surface morphological changes on the human dental enamel and cement after the Er:YAG laser irradiation at different incidence angles

    International Nuclear Information System (INIS)

    Tannous, Jose Trancoso

    2001-01-01

    This is a morphological analysis study through SEM of the differences of the laser tissue interaction as a function of the laser beam irradiation angle, under different parameters of energy. Fourteen freshly extracted molars stored in a 0,9% sodium chloride solution were divided in seven pairs and were irradiated with 100, 200, 300, 400, 500, 600 and 700 mJ per pulse, respectively. Each sample received three enamel irradiations and three cement irradiations, either in the punctual or in the contact mode, one near to the other, with respectively 30, 45 and 90 inclinations degrees of dental surface-laser-beam incidence. Four Er:YAG pulses (2,94 μm, 7-20 Hz, 0,1-1 J energy/pulse - Opus 20 - Opus Dent) with water cooling system (0,4 ml/s) were applied. After the laser irradiation the specimens were analysed through scanning electron microscope (SEM). The results were analysed by SEM micrographs showing a great difference on the laser tissue interaction characteristics as a function of the irradiation angle of the laser beam. All the observations led to conclude that, considering the laser parameters used, the incidence angle variation is a very important parameter regarding the desired morphological effects. This represents an extremely relevant detail on the technical description of the Er:YAG laser irradiation protocols on dental tissues. (author)

  11. Results of a modified non-penetrating deep sclerectomy in the treatment of open angle glaucoma with or without cataract

    Directory of Open Access Journals (Sweden)

    George Kitsos

    2010-06-01

    Full Text Available George Kitsos1, Miltiades Aspiotis1, Yannis Alamanos2, Konstantinos Psilas11Department of Ophthalmology, Medical School, University of Ioannina, Ioannina, Greece; 2Department of Hygiene and Epidemiology, Medical School, University of Patras, Patras, GreecePurpose: To present the technique of a modified deep sclerectomy, which we will call “reversed” deep sclerectomy (RDS and the results and our observations of its use in patients with open angle glaucoma (OAG and with or without cataract extraction (phacoemulsification.Materials and methods: This prospective study included 132 eyes which underwent RDS: 37 eyes (group A with uncontrolled OAG and 95 eyes (group B with OAG and visually significant cataract. Mean pressure preoperatively for group A was 24.48 ± 4.92 mmHg and for group B was 22.99 ± 3.00. The mean number of antiglaucoma drugs received was 2.97 ± 0.69 and 2.56 ± 0.73 for groups A and B respectively. The RDS was performed where the deep scleral stroma is prepared in 2 parts, folded and inserted under the lateral sides of the sclerectomy, and the Schlemm’s canal is opened prior to deep scleral stroma preparation. Cataract was extracted by phacoemulsification through the same scleral opening. The follow-up for group A was 22.23 ± 10.18 months and for group B, 25.36 ± 10.12 months. Results: Postoperative intraocular pressure (IOP ≤ 21 mmHg was achieved for group A in 40.5% without antiglaucoma drugs and 94.6% with antiglaucoma drugs, and for group B in 66.3% and in 94.7% respectively. Mean IOP reduction was 7.02 ± 6.35 mmHg (28.67%, P < 0.05 for group A and 5.26 ± 3.72 mmHg (25.06%, P ≤ 0.05 for group B, while mean drug reduction was 1.97 ± 1.09 (P < 0.01 and 2.14 ± 0.95 (P ≤ 0.01 respectively. 5-Fluorouracil was used in 8 eyes of group A and in 5 eyes of group B.Conclusion: In the follow-up time during which the two groups were under study, the RDS was effective with a few complications, similar to the classic deep

  12. Analyzing the Influence of the Angles of Incidence and Rotation on MBU Events Induced by Low LET Heavy Ions in a 28-nm SRAM-Based FPGA

    Science.gov (United States)

    Tonfat, Jorge; Kastensmidt, Fernanda Lima; Artola, Laurent; Hubert, Guillaume; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Macchione, Eduardo L. A.; Silveira, Marcilei A. G.

    2017-08-01

    This paper shows the impact of low linear energy transfer heavy ions on the reliability of 28-nm Bulk static random access memory (RAM) cells from Artix-7 field-programmable gate array. Irradiation tests on the ground showed significant differences in the multiple bit upset cross section of configuration RAM and block RAM memory cells under various angles of incidence and rotation of the device. Experimental data are analyzed at transistor level by using the single-event effect prediction tool called multiscale single-event phenomenon prediction platform coupled with SPICE simulations.

  13. Accessible length scale of the in-plane structure in polarized neutron off-specular and grazing-incidence small-angle scattering measurements

    Science.gov (United States)

    Maruyama, R.; Bigault, T.; Wildes, A. R.; Dewhurst, C. D.; Saerbeck, T.; Honecker, D.; Yamazaki, D.; Soyama, K.; Courtois, P.

    2017-06-01

    Polarized neutron off-specular and grazing-incidence small-angle scattering measurements are useful methods to investigate the in-plane structure and its correlation of layered systems. Although these measurements give information on complementary and overlapping length scale, the different characteristics between them need to be taken into account when performed. In this study, the difference in the accessible length scale of the in-plane structure, which is one of the most important characteristics, was discussed using an Fe/Si multilayer together with simulations based on the distorted wave Born approximation.

  14. Detection of short range order in SiO{sub 2} thin-films by grazing-incidence wide and small-angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Kohki, E-mail: nagata.koki@iri-tokyo.jp [Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064 (Japan); School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Ogura, Atsushi [School of Science and Technology, Meiji University, 1-1-1 Higashimita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Hirosawa, Ichiro [Japan Synchrotron Radiation Research Institute (JASRI), 1-1-1, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Suwa, Tomoyuki; Teramoto, Akinobu; Ohmi, Tadahiro [New Industry Creation Hatchery Center, Tohoku University, 6-6-10 Aramakiazaaoba, Aoba-ku, Sendai, Miyagi 980-8579 (Japan)

    2016-04-21

    The effects of the fabrication process conditions on the microstructure of silicon dioxide thin films of <10 nm thickness are presented. The microstructure was investigated using grazing-incidence wide and small-angle X-ray scattering methods with synchrotron radiation. The combination of a high brilliance light source and grazing incident configuration enabled the observation of very weak diffuse X-ray scattering from SiO{sub 2} thin films. The results revealed different microstructures, which were dependent on oxidizing species or temperature. The micro-level properties differed from bulk properties reported in the previous literature. It was indicated that these differences originate from inner stress. The detailed structure in an amorphous thin film was not revealed owing to detection difficulties.

  15. Preliminary proposals for extending the ENDF format to allow incident charged particles and energy-angle correlation for emitted particles

    International Nuclear Information System (INIS)

    MacFarlane, R.E.; Stewart, L.; Hale, G.M.; Dunford, C.L.

    1984-04-01

    This rewrite of Data Formats and Procedures for the Evaluated Nuclear Data File, ENDF pertains to the latest version, ENDF/B-VI. Earlier versions provided representations for neutron cross sections and distributions, photon production from neutron reactions, a limited amount of charged-particle production from neutron reactions, photo-atomic interaction data, thermal neutron scattering data, and radionuclide production and decay data (including fission products). This version allows higher incident energies, adds more complete descriptions of the distributions of emitted particles, and provides for incident charged particles and photo-nuclear data by partitioning the ENDF library into sublibraries. Decay data, fission product yield data, thermal scattering data, and photo-atomic data have also been formally placed in sublibraries. In addition, this rewrite represents an extensive update to the Version V manual

  16. Preparation of a durable superhydrophobic membrane by electrospinning poly (vinylidene fluoride) (PVDF) mixed with epoxy-siloxane modified SiO2 nanoparticles: a possible route to superhydrophobic surfaces with low water sliding angle and high water contact angle.

    Science.gov (United States)

    Wang, Shuai; Li, Yapeng; Fei, Xiaoliang; Sun, Mingda; Zhang, Chaoqun; Li, Yaoxian; Yang, Qingbiao; Hong, Xia

    2011-07-15

    A durable superhydrophobic surface with low water sliding angle (SA) and high water contact angle (CA) was obtained by electrospinning poly (vinylidene fluoride) (PVDF) which was mixed with epoxy-siloxane modified SiO(2) nanoparticles. To increase the roughness, modified SiO(2) nanoparticles were introduced into PVDF precursor solution. Then in the electrospinning process, nano-sized SiO(2) particles irregularly inlayed (it could also be regard as self-assembly) in the surface of the micro-sized PVDF mini-islands so as to form a dual-scale structure. This structure was responsible for the superhydrophobicity and self-cleaning property. In addition, epoxy-siloxane copolymer was used to modify the surface of SiO(2) nanoparticles so that the SiO(2) nanoparticles could stick to the surface of the micro-sized PVDF mini-islands. Through the underwater immersion test, the SiO(2) nanoparticles cannot be separated from PVDF easily so as to achieve the effect of durability. We chiefly explore the surface wettability and the relationship between the mass ratio of modified SiO(2) nanoparticles/PVDF and the CA, SA of electrospun mat. As the content of modified SiO(2) nanoparticles increased, the value of CA increased, ranging from 145.6° to 161.2°, and the water SA decreased to 2.17°, apparently indicating that the membrane we fabricated has a perfect effect of superhydrophobicity. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. A large-area, wide-incident-angle, and polarization-independent plasmonic color filter for glucose sensing

    Science.gov (United States)

    Lin, Yu-Sheng; Chen, Wenjun

    2018-01-01

    We develop an effective method for glucose sensing by using a plasmonic color filter (PCF) integrated with a microfluidic chip. The morphology of PCF is composed of hybrid nanopillars fabricated with SiO2 and Au thin-films on silicon substrate. It exhibits angle-independence, polarization-independence and wafer-level fabrication, which are the most important factors for color filters for industrial applications. The shift of resonant wavelength is 56 nm with a stable bandwidth (∼30 nm) by varying concentration of glucose solution. The sensitivity is 157.61 nm/RIU and the corresponding figure-of-merit is 5.25. Such strategy can be exploited to further increase the detection and potentially enter the ultra-strong coupling regime in chemical solution sensors.

  18. On the Emission of Electrons from Solid H_2 and D_2 by Bombardment with 1-3 keV Electrons up to Very Large Angles of Incidence

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.

    1982-01-01

    Electron emission, i.e. electron reflection (ER) and secondary electron emission (SEE), was studied for solid H2 and D2 for oblique incidence of 1-3 keV electrons up to an angle of incidence θ of 83°. The ER coefficient η was small at low angles, and rose rapidly with increasing θ above 60...... at the largest angles. The results agree well with the existing qualitative tendencies described in the literature. The variation with the angle of incidence shows a fair agreement with an estimate based on data for the angular distribution of electrons ejected from ionized hydrogen molecules. In addition......, an ionization cascade treatment leads to an expression for the behavior of the yield of those secondary electrons that are generated directly by the primaries. The agreement with experimental data is good...

  19. Single-beam integrating sphere spectrophotometer for reflectance and transmittance measurements versus angle of incidence in the solar wavelength range on diffuse and specular samples

    Science.gov (United States)

    Nostell, Per; Roos, Arne; Rönnow, Daniel

    1999-05-01

    A multipurpose instrument for the measurement of reflectance and transmittance versus angle of incidence for both specular and diffuse samples in the solar wavelength range has been constructed and evaluated. The instrument operates in the single-beam mode and uses a common light source for three experimental setups. Two integrating spheres, 20 cm in diameter, are used for diffuse transmittance and reflectance measurements. The transmittance sphere can be turned around an axis through the sample to vary the angle of incidence. The reflectance sphere uses a center mounted sample and a special feature is the position of the detector, which is mounted on the sample holder at the center of the sphere. This way the detector always sees the same part of the sphere wall and no light can reach the detector directly from the sample. The third setup is an absolute instrument for specular samples. It uses a small averaging sphere as a detector. The detector is mounted on an arm which rotates around the center of the sample, and it can thus pick up both the reflected and transmitted beams including all multiply reflected components. The averaging sphere detector is insensitive to small side shifts of the detected beams and no multiple reflections between detector and optical system occur. In this report a number of calibration procedures are presented for the three experimental setups and models for the calculation of correct transmittance and reflectance values from measured data are presented. It is shown that for integrating sphere measurements, the geometry of the sphere and the diffusivity of the sample as well as the sphere wall reflectance and port losses are important factors that influence the result. For the center mounted configuration these factors are particularly important and special emphasis is given to the evaluation of the reflectance sphere model. All three instrument setups are calibrated using certified reference materials and nonscattering mirrors and

  20. Investigating the use of the dual-polarized and large incident angle of SAR data for mapping the fluvial and aeolian deposits

    Science.gov (United States)

    Gaber, Ahmed; Amarah, Bassam A.; Abdelfattah, Mohamed; Ali, Sarah

    2017-12-01

    Mapping the spatial distributions of the fluvial deposits in terms of particles size as well as imaging the near-surface features along the non-vegetated aeolian sand-sheets, provides valuable geological information. Thus this work aims at investigating the contribution of the dual-polarization SAR data in classifying and mapping the surface sediments as well as investigating the effect of the radar incident-angle on improving the images of the hidden features under the desert sand cover. For mapping the fluvial deposits, the covariance matrix ([C2]) using four dual-polarized ALOS/PALSAR-1 scenes cover the Wadi El Matulla, East Qena, Egypt were generated. This [C2] matrix was used to generate a supervised classification map with three main classes (gravel, gravel/sand and sand). The polarimetric scattering response, spectral reflectance and temperatures brightness of these 3 classes were extracted. However for the aeolian deposits investigation, two Radarsat-1 and three full-polarimetric ALOS/PALSAR-1 images, which cover the northwestern sandy part of Sinai, Egypt were calibrated, filtered, geocoded and ingested in a GIS database to image the near-surface features. The fluvial mapping results show that the values of the radar backscattered coefficient (σ°) and the degree of randomness of the obtained three classes are increasing respectively by increasing their grain size. Moreover, the large incident angle (θi = 39.7) of the Radarsat-1 image has revealed a meandering buried stream under the sand sheet of the northwestern part of Sinai. Such buried stream does not appear in the other optical, SRTM and SAR dataset. The main reason is the enhanced contrast between the low backscattered return from the revealed meandering stream and the surroundings as a result of the increased backscattering intensity, which is related to the relatively large incident angle along the undulated surface of the study area. All archaeological observations support the existence of

  1. The effect of oblique angle of sound incidence, realistic edge conditions, curvature and in-plane panel stresses on the noise reduction characteristics of general aviation type panels

    Science.gov (United States)

    Grosveld, F.; Lameris, J.; Dunn, D.

    1979-01-01

    Experiments and a theoretical analysis were conducted to predict the noise reduction of inclined and curved panels. These predictions are compared to the experimental results with reasonable agreement between theory and experiment for panels under an oblique angle of sound incidence. Theoretical as well as experimental results indicate a big increase in noise reduction when a flat test panel is curved. Further curving the panel slightly decreases the noise reduction. Riveted flat panels are shown to give a higher noise reduction in the stiffness-controlled frequency region, while bonded panels are superior in this region when the test panel is curved. Experimentally measured noise reduction characteristics of flat aluminum panels with uniaxial in-plane stresses are presented and discussed. These test results indicate an important improvement in the noise reduction of these panels in the frequency range below the fundamental panel/cavity frequency.

  2. Analysis of mesoporous thin films by X-ray reflectivity, optical reflectivity and grazing incidence small angle X-ray scattering

    International Nuclear Information System (INIS)

    Gibaud, A.; Dourdain, S.; Vignaud, G.

    2006-01-01

    It is well-established that X-ray reflectivity (XR) is an invaluable tool to investigate the structure of thin films. Indeed, this technique provides under correct analysis, the electron density profile of thin films in the direction perpendicular to the substrate. For thin films that exhibit lateral ordering at the nanometer scale, grazing incidence small angle X-ray scattering (GISAXS) ideally complements the XR technique to measure the scattering in off-specular directions. As typical examples, XR and GISAXS data of mesoporous silica thin films and porous materials are presented. The analysis of the XR curve allows to determine the porosity of the film. We also show that the combination of X-ray and visible optical reflection provides information about the index of refraction of thin films. Finally we report how capillary condensation of water can be monitored by XR and GISAXS

  3. Monte Carlo simulation of electron depth distribution and backscattering for carbon films deposited on aluminium as a function of incidence angle and primary energy

    International Nuclear Information System (INIS)

    Dapor, Maurizio

    2005-01-01

    Carbon films are deposited on various substrates (polymers, polyester fabrics, polyester yarns, metal alloys) both for experimental and technological motivations (medical devices, biocompatible coatings, food package and so on). Computational studies of the penetration of electron beams in supported thin film of carbon are very useful in order to compare the simulated results with analytical techniques data (obtained by scanning electron microscopy and/or Auger electron spectroscopy) and investigate the film characteristics. In the present paper, the few keV electron depth distribution and backscattering coefficient for the special case of film of carbon deposited on aluminium are investigated, by a Monte Carlo simulation, as a function of the incidence angle and primary electron energy. The simulated results can be used as a way to evaluate the carbon film thickness by a set of measurements of the backscattering coefficient

  4. Surface oxidation of a Melinex 800 PET polymer material modified by an atmospheric dielectric barrier discharge studied using X-ray photoelectron spectroscopy and contact angle measurement

    International Nuclear Information System (INIS)

    Cui Naiyi; Upadhyay, Deepesh J.; Anderson, Colin A.; Meenan, Brian J.; Brown, Norman M.D.

    2007-01-01

    Surface properties of a Melinex 800 PET polymer material modified by an atmospheric-pressure air dielectric barrier discharge (DBD) have been studied using X-ray photoelectron microscopy (XPS) and contact angle measurement. The results show that the material surface treated by the DBD was modified significantly in chemical composition, with the highly oxidised carbon species increasing as the surface processing proceeds. The surface hydrophilicity was dramatically improved after the treatment, with the surface contact angle reduced from 81.8 o for the as-supplied sample to lower than 50 deg. after treatment. Post-treatment recovery effect is found after the treated samples were stored in air for a long period of time, with the ultimate contact angles, as measured, being stabilised in the range 58-69 deg. after the storage, varying with the DBD-treatment power density. A great amount of the C-O type bonding formed during the DBD treatment was found to be converted into the C=O type during post-treatment storage. A possible mechanism for this bond conversion has been suggested

  5. Microstructural characterization of a modified 706-type Ni-Fe superalloy by small-angle neutron scattering and electron microscopy

    Czech Academy of Sciences Publication Activity Database

    Del Genovese, D.; Strunz, Pavel; Mukherji, D.; Gilles, R.; Rösler, J.

    36A, - (2005), s. 3439-3450 ISSN 1073-5623 Institutional research plan: CEZ:AV0Z10480505 Keywords : superalloys * small-angle neutron scattering Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.232, year: 2005

  6. Accurate Molecular Orientation Analysis Using Infrared p-Polarized Multiple-Angle Incidence Resolution Spectrometry (pMAIRS) Considering the Refractive Index of the Thin Film Sample.

    Science.gov (United States)

    Shioya, Nobutaka; Shimoaka, Takafumi; Murdey, Richard; Hasegawa, Takeshi

    2017-06-01

    Infrared (IR) p-polarized multiple-angle incidence resolution spectrometry (pMAIRS) is a powerful tool for analyzing the molecular orientation in an organic thin film. In particular, pMAIRS works powerfully for a thin film with a highly rough surface irrespective of degree of the crystallinity. Recently, the optimal experimental condition has comprehensively been revealed, with which the accuracy of the analytical results has largely been improved. Regardless, some unresolved matters still remain. A structurally isotropic sample, for example, yields different peak intensities in the in-plane and out-of-plane spectra. In the present study, this effect is shown to be due to the refractive index of the sample film and a correction factor has been developed using rigorous theoretical methods. As a result, with the use of the correction factor, organic materials having atypical refractive indices such as perfluoroalkyl compounds ( n = 1.35) and fullerene ( n = 1.83) can be analyzed with high accuracy comparable to a compound having a normal refractive index of approximately 1.55. With this improved technique, we are also ready for discriminating an isotropic structure from an oriented sample having the magic angle of 54.7°.

  7. Study of the gel films of Acetobacter Xylinum cellulose and its modified samples by {sup 1}H NMR cryoporometry and small-angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Babushkina, T. A.; Klimova, T. P. [Russian Academy of Sciences, Nesmeyanov Institute of Organoelement Compounds (Russian Federation); Shtykova, E. V.; Dembo, K. A.; Volkov, V. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Khripunov, A. K. [Russian Academy of Sciences, Institute of Macromolecular Compounds (Russian Federation); Klechkovskaya, V. V., E-mail: klechvv@ns.crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2010-03-15

    Gel films of Acetobacter Xylinum cellulose and its modified samples have been investigated by 1H nuclear magnetic resonance (NMR) cryoporometry and small-angle X-ray scattering. The joint use of these two methods made it possible to characterize the sizes of aqueous pores in gel films and estimate the sizes of structural inhomogeneities before and after the sorption of polyvinylpyrrolidone and Se{sub 0} nanoparticles (stabilized by polyvinylpyrrolidone) into the films. According to small-angle X-ray scattering data, the sizes of inhomogeneities in a gel film change only slightly upon the sorption of polyvinylpyrrolidone and nanoparticles. The impregnated material is sorbed into water-filled cavities that are present in the gel film. {sup 1}H NMR cryoporometry allowed us to reveal the details of changes in the sizes of small aqueous pores during modifications.

  8. Quantitative determination of the lateral density and intermolecular correlation between proteins anchored on the membrane surfaces using grazing incidence small-angle X-ray scattering and grazing incidence X-ray fluorescence.

    Science.gov (United States)

    Abuillan, Wasim; Vorobiev, Alexei; Hartel, Andreas; Jones, Nicola G; Engstler, Markus; Tanaka, Motomu

    2012-11-28

    As a physical model of the surface of cells coated with densely packed, non-crystalline proteins coupled to lipid anchors, we functionalized the surface of phospholipid membranes by coupling of neutravidin to biotinylated lipid anchors. After the characterization of fine structures perpendicular to the plane of membrane using specular X-ray reflectivity, the same membrane was characterized by grazing incidence small angle X-ray scattering (GISAXS). Within the framework of distorted wave Born approximation and two-dimensional Percus-Yevick function, we can analyze the form and structure factors of the non-crystalline, membrane-anchored proteins for the first time. As a new experimental technique to quantify the surface density of proteins on the membrane surface, we utilized grazing incidence X-ray fluorescence (GIXF). Here, the mean intermolecular distance between proteins from the sulfur peak intensities can be calculated by applying Abelé's matrix formalism. The characteristic correlation distance between non-crystalline neutravidin obtained by the GISAXS analysis agrees well with the intermolecular distance calculated by GIXF, suggesting a large potential of the combination of GISAXS and GIXF in probing the lateral density and correlation of non-crystalline proteins displayed on the membrane surface.

  9. On the Emission of Electrons from Solid H_2 and D_2 by Bombardment with 1-3 keV Electrons up to Very Large Angles of Incidence

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.

    1982-01-01

    -65°. Only at large angles and low energies were the results different for H2 and D2, those for H2 being the lower ones. The angular variation of the SEE coefficient δ may be written as δ(θ)=δ(0)(cos θ)3/2 up to an angle of 65-75°. For H2 the SEE coefficient is around 0.65 times that the D2 except......Electron emission, i.e. electron reflection (ER) and secondary electron emission (SEE), was studied for solid H2 and D2 for oblique incidence of 1-3 keV electrons up to an angle of incidence θ of 83°. The ER coefficient η was small at low angles, and rose rapidly with increasing θ above 60...... at the largest angles. The results agree well with the existing qualitative tendencies described in the literature. The variation with the angle of incidence shows a fair agreement with an estimate based on data for the angular distribution of electrons ejected from ionized hydrogen molecules. In addition...

  10. A Multicountry Ecological Study of Cancer Incidence Rates in 2008 with Respect to Various Risk-Modifying Factors

    Directory of Open Access Journals (Sweden)

    William B. Grant

    2013-12-01

    Full Text Available Observational and ecological studies are generally used to determine the presence of effect of cancer risk-modifying factors. Researchers generally agree that environmental factors such as smoking, alcohol consumption, poor diet, lack of physical activity, and low serum 25-hdyroxyvitamin D levels are important cancer risk factors. This ecological study used age-adjusted incidence rates for 21 cancers for 157 countries (87 with high-quality data in 2008 with respect to dietary supply and other factors, including per capita gross domestic product, life expectancy, lung cancer incidence rate (an index for smoking, and latitude (an index for solar ultraviolet-B doses. The factors found to correlate strongly with multiple types of cancer were lung cancer (direct correlation with 12 types of cancer, energy derived from animal products (direct correlation with 12 types of cancer, inverse with two, latitude (direct correlation with six types, inverse correlation with three, and per capita gross national product (five types. Life expectancy and sweeteners directly correlated with three cancers, animal fat with two, and alcohol with one. Consumption of animal products correlated with cancer incidence with a lag time of 15–25 years. Types of cancer which correlated strongly with animal product consumption, tended to correlate weakly with latitude; this occurred for 11 cancers for the entire set of countries. Regression results were somewhat different for the 87 high-quality country data set and the 157-country set. Single-country ecological studies have inversely correlated nearly all of these cancers with solar ultraviolet-B doses. These results can provide guidance for prevention of cancer.

  11. [Does the surgical technique modify the incidence of local recurrence after mastectomy?].

    Science.gov (United States)

    Aeberhard, P

    1992-05-01

    This article discusses operative technique in relation to the prevention of local recurrence following modified radical mastectomy (MM) for carcinoma of the breast. As with any other surgical procedure, a satisfactory outcome requires both a correct indication and attention to the details of operative technique. The indications for MM may be defined from the currently accepted contraindications to breast preservation, while most of the contraindications to MM relate to the presence of a stage IIIb or IV carcinoma. The ideal treatment needs to be defined for the individual case, avoiding both unnecessary overtreatment with its associated morbidity and dangerous undertreatment with consequent reduction of the chance for cure. In our view, confirmation of the diagnosis by an excisional biopsy with frozen section examination should be obtained irrespective of a positive finding in an aspirated specimen. The incision for biopsy must be chosen in such a way that it will be encompassed by a subsequent mastectomy incision. When mastectomy is performed the cavity of the excisional biopsy must not be entered. This includes preservation of the barrier of the pectoralis fascia. When breast preservation is an option, the excisional biopsy must fulfill the criteria of a lumpectomy or tumorectomy, which include a 0.5 to 1 cm macroscopically tumor-free margin, orientation of the specimen by sutures, and immersion of the specimen in india ink. As the extent of intraductal component cannot be reliably determined by frozen section examination, waiting for the definitive pathology report may be better than an immediate decision to perform a mastectomy or breast preservation. The skin incision for mastectomy is transverse or slightly oblique, ending laterally about five cm below the axillary pit. The skin flaps must not include the full thickness of the subcutaneous fatty tissue. The preserved layer of fatty tissue must not be irregular. Axillary dissection of levels I and II is

  12. Morphology and contact angle studies of poly(styrene-co-acrylonitrile modified epoxy resin blends and their glass fibre reinforced composites

    Directory of Open Access Journals (Sweden)

    2007-06-01

    Full Text Available In this study, the surface characteristics of blends and composites of epoxy resin were investigated. Poly(styrene-co-acylonitrile (SAN was used to modify diglycedyl ether of bisphenol-A (DGEBA type epoxy resin cured with diamino diphenyl sulfone (DDS and the modified epoxy resin was used as the matrix for fibre reinforced composites (FRP’s. E-glass fibre was used as the fibre reinforcement. The scanning electron micrographs of the fractured surfaces of the blends and composites were analyzed. Morphological analysis revealed different morphologies such as dispersed, cocontinuous and phase-inverted structures for the blends. Contact angle studies were carried out using water and methylene iodide at room temperature. The solid surface energy was calculated using harmonic mean equations. Blending of epoxy resin increases its contact angle. The surface free energy, work of adhesion, interfacial free energy, spreading coefficient and Girifalco-Good’s interaction parameter were changed significantly in the case of blends and composites. The incorporation of thermoplastic and glass fibre reduces the wetting and hydrophilicity of epoxy resin.

  13. Surface Plasmon Polariton Resonance of Gold, Silver, and Copper Studied in the Kretschmann Geometry: Dependence on Wavelength, Angle of Incidence, and Film Thickness

    Science.gov (United States)

    Takagi, Kentaro; Nair, Selvakumar V.; Watanabe, Ryosuke; Seto, Keisuke; Kobayashi, Takayoshi; Tokunaga, Eiji

    2017-12-01

    Surface plasmon polariton (SPP) resonance spectra for noble metals (Au, Ag, and Cu) were comprehensively studied in the Kretschmann attenuated total reflection (ATR) geometry, in the wavelength (λ) range from 300 to 1000 nm with the angle of incidence (θ) ranging from 45 to 60° and the film thickness (d) ranging from 41 to 76 nm. The experimental plasmon resonance spectra were reproduced by a calculation that included the broadening effects as follows: (1) the imaginary part of the bulk dielectric constant, (2) the thickness-dependent radiative coupling of the SPP at the metal-air interface to the prism, (3) the lack of conservation of the wavevector parallel to the interface kx(k||) caused by the surface roughness, (4) scanning λ at a fixed θ (changing both energy and kx at the same time) over the SPP dispersion relation. For Au and Ag, the experimental results were in good agreement with the calculated results using the bulk dielectric constants, showing no film thickness dependence of the plasmon resonance energy. A method to extract the true width of the plasmon resonance from raw ATR spectra is proposed and the results are rigorously compared with those expected from the bulk dielectric function given in the literature. For Au and Ag, the width increases with energy, in agreement with that expected from the relaxation of bulk free electrons including the electron-electron interaction, but there is clear evidence of extra broadening, which is more significant for thinner films, possibly due to relaxation pathways intrinsic to plasmons near the interface. For Cu, the visibility of the plasmon resonance critically depends on the evaporation conditions, and low pressures and fast deposition rates are required. Otherwise, scattering from the surface roughness causes considerable broadening of the plasmon resonance, resulting in an apparently fixed resonance energy without clear incident angle dependence. For Cu, the observed plasmon dispersion agrees well with

  14. Three-Dimensional Morphology Control Yielding Enhanced Hole Mobility in Air-Processed Organic Photovoltaics: Demonstration with Grazing-Incidence Wide-Angle X-ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Levi M. J. [School of Polymers; Bhattacharya, Mithun [School of Polymers; Wu, Qi [School of Polymers; Youm, Sang Gil [Department of Chemistry, Louisiana State University, 232 Choppin Hall, Baton Rouge, Louisiana 70803, United States; Nesterov, Evgueni E. [Department of Chemistry, Louisiana State University, 232 Choppin Hall, Baton Rouge, Louisiana 70803, United States; Morgan, Sarah E. [School of Polymers

    2017-06-28

    Polymer organic photovoltaic (OPV) device performance is defined by the three-dimensional morphology of the phase-separated domains in the active layer. Here, we determine the evolution of morphology through different stages of tailored solvent vapor and thermal annealing techniques in air-processed poly(3-hexylthiophene-2,5-diyl)/phenyl-C61-butyric acid methyl ester-based OPV blends. A comparative evaluation of the effect of solvent type used for vapor annealing was performed using grazing-incidence wide-angle X-ray scattering, atomic force microscopy, and UV–vis spectroscopy to probe the active-layer morphology. A nonhalogenated orthogonal solvent was found to impart controlled morphological features within the exciton diffusion length scales, enhanced absorbance, greater crystallinity, increased paracrystalline disorder, and improved charge-carrier mobility. Low-boiling, fast-diffusing isopropanol allowed the greatest control over the nanoscale structure of the solvents evaluated and yielded a cocontinuous morphology with narrowed domains and enhanced paths for the charge carrier to reach the anode.

  15. Three-Dimensional Morphology Control Yielding Enhanced Hole Mobility in Air-Processed Organic Photovoltaics: Demonstration with Grazing-Incidence Wide-Angle X-ray Scattering.

    Science.gov (United States)

    Moore, Levi M J; Bhattacharya, Mithun; Wu, Qi; Youm, Sang Gil; Nesterov, Evgueni E; Morgan, Sarah E

    2017-07-12

    Polymer organic photovoltaic (OPV) device performance is defined by the three-dimensional morphology of the phase-separated domains in the active layer. Here, we determine the evolution of morphology through different stages of tailored solvent vapor and thermal annealing techniques in air-processed poly(3-hexylthiophene-2,5-diyl)/phenyl-C 61 -butyric acid methyl ester-based OPV blends. A comparative evaluation of the effect of solvent type used for vapor annealing was performed using grazing-incidence wide-angle X-ray scattering, atomic force microscopy, and UV-vis spectroscopy to probe the active-layer morphology. A nonhalogenated orthogonal solvent was found to impart controlled morphological features within the exciton diffusion length scales, enhanced absorbance, greater crystallinity, increased paracrystalline disorder, and improved charge-carrier mobility. Low-boiling, fast-diffusing isopropanol allowed the greatest control over the nanoscale structure of the solvents evaluated and yielded a cocontinuous morphology with narrowed domains and enhanced paths for the charge carrier to reach the anode.

  16. Association of sleep duration and incidence of diabetes modified by tea consumption: a report from the Shanghai men's health study.

    Science.gov (United States)

    Dai, Fei; Cai, Hui; Li, Honglan; Yang, Gong; Ji, Bu-Tian; Zheng, Wei; Xiang, Yong-Bing; Shu, Xiao-Ou

    2017-10-01

    To evaluate the association between sleep duration and the incidence of diabetes stratified by sleep-related factors among Chinese men. This study included 34,825 men who provided information on sleep-related questions in the Shanghai Men's Health Study, a population-based cohort study conducted in Shanghai, China from 2002 to 2011. Participants were excluded who had a history of diabetes or who were diagnosed with diabetes within 2 years of recruitment. Cox regression was employed to evaluate the influence of sleep duration and its interaction with sleep-related factors on diabetes risk. A total of 1521 incident cases were documented during a median of 5.6 follow-up years. Adjusted hazard ratios and 95% confidence intervals were 1.0 (0.9-1.1) and 1.2 (1.0-1.3) for men who slept <7 and ≥8 h per day, respectively, compared with those who slept 7 h per day (p trend  = 0.01). Stratified analyses revealed that the association between sleep duration and risk of diabetes was only statistically significant among current smokers and regular drinkers, never tea drinkers, men with a high body mass index, hypertension or comorbidity, and men who did not work nightshift or who snored. A statistically significant interaction between tea drinking and sleep duration was observed (p interaction  = 0.01). The above association patterns remained when daytime nappers were excluded from the analyses. The data suggested that longer sleep duration, particularly among individuals already exhibiting factors linked to poor quality of sleep, was associated with diabetes. The association between sleep duration and diabetes may be modified by tea drinking, especially in older men or men with more sleep-related factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Analysis of InGaN nanodots grown by droplet heteroepitaxy using grazing incidence small-angle X-ray scattering and electron microscopy

    Science.gov (United States)

    Woodward, J. M.; Nikiforov, A. Yu.; Ludwig, K. F.; Moustakas, T. D.

    2017-08-01

    We present a detailed structural investigation of self-assembled indium gallium nitride nanodots grown on c-plane aluminum nitride templates by the droplet heteroepitaxy technique in a plasma-assisted molecular beam epitaxy reactor. Various growth parameters, including the total coverage of the metal species, relative and total metal effusion fluxes, and nitridation temperature were investigated. Analyses of in situ reflection high-energy electron diffraction patterns and comparison with simulations showed that the resulting crystal structure was a mixture of wurtzite and twinned zinc blende phases, with the zinc blende phase increasingly dominant for lower metal coverages and lower nitridation temperatures, and the wurtzite phase increasingly dominant for higher nitridation temperature. Studies by field emission scanning electron microscopy and atomic force microscopy revealed that the nanodots exhibit trimodal size distributions, with the dot morphologies of the intermediate size mode often resembling aggregations of distinct clusters. Nanodots grown at higher nitridation temperatures had larger inter-dot spacings, with hexagonal in-plane ordering observable at a sufficiently high temperature. Using grazing incidence small angle X-ray scattering, we determined the nanodots to be approximately truncated cone shaped, and extracted the mean radius, height, and inter-dot distance for each distribution. Microstructural investigations of the nanodots by cross-sectional transmission electron microscopy indicated that the majority of the dots were formed in dislocation-free regions, and confirmed that the intermediate size dots were approximately truncated cone shaped and consisted of both zinc blende and wurtzite regions. Mapping of the elemental distributions by energy dispersive X-ray spectroscopy in scanning transmission electron microscopy mode indicated highly nonuniform indium distributions within both small and intermediate size dots which are potentially

  18. Influence of the incidence angle on the morphology of enamel and dentin under Er:YAG laser irradiation; Estudo da influencia da angulacao do feixe laser na morfologia de esmalte e dentina irradiados com laser de Er:YAG

    Energy Technology Data Exchange (ETDEWEB)

    Junqueira Junior, Duilio Naves

    2002-07-01

    The purpose of this study is to make an in vitro evaluation, using scanning electron microscopy, of the influence of the laser beam irradiation angle on the enamel and dentin morphology. These tissues were both irradiated by Er:YAG Laser, with the same energy parameter. Twenty-four incisive bovine teeth were used, separated in eight groups, four of enamel, and four of dentin, with three specimens in each group. Each specimen was submitted to three laser applications, varying the incidence angle, between the laser and the tooth surface, at 90, 50 and 20 degrees. The applied frequency was 2 Hz, with 20 pulses in each application. The KaVo Key Laser 3 was employed, wavelength at 2940 nm, adjustable energy from 40 to 600 mJ and repetition rate from 1 to 25 Hz. The groups were distributed according to the energy parameter as follows - enamel: 250 mJ; 300 mJ; 350 mJ and 400 mJ; dentin: 200 mJ; 250 mJ; 300 mJ and 350 mJ. The results evidenced the Laser incidence angle importance; it is an essential parameter in the protocol of utilization and it should not be disregarded. The observations of this study allow to conclude that the Laser incidence angle has direct influence on the morphological aspect of the alterations produced in enamel and dentin. (author)

  19. Beyond Risk Compensation: Clusters of Antiretroviral Treatment (ART) Users in Sexual Networks Can Modify the Impact of ART on HIV Incidence

    Science.gov (United States)

    Delva, Wim; Helleringer, Stéphane

    2016-01-01

    Introduction Concerns about risk compensation—increased risk behaviours in response to a perception of reduced HIV transmission risk—after the initiation of ART have largely been dispelled in empirical studies, but other changes in sexual networking patterns may still modify the effects of ART on HIV incidence. Methods We developed an exploratory mathematical model of HIV transmission that incorporates the possibility of ART clusters, i.e. subsets of the sexual network in which the density of ART patients is much higher than in the rest of the network. Such clusters may emerge as a result of ART homophily—a tendency for ART patients to preferentially form and maintain relationships with other ART patients. We assessed whether ART clusters may affect the impact of ART on HIV incidence, and how the influence of this effect-modifying variable depends on contextual variables such as HIV prevalence, HIV serosorting, coverage of HIV testing and ART, and adherence to ART. Results ART homophily can modify the impact of ART on HIV incidence in both directions. In concentrated epidemics and generalized epidemics with moderate HIV prevalence (≈ 10%), ART clusters can enhance the impact of ART on HIV incidence, especially when adherence to ART is poor. In hyperendemic settings (≈ 35% HIV prevalence), ART clusters can reduce the impact of ART on HIV incidence when adherence to ART is high but few people living with HIV (PLWH) have been diagnosed. In all contexts, the effects of ART clusters on HIV epidemic dynamics are distinct from those of HIV serosorting. Conclusions Depending on the programmatic and epidemiological context, ART clusters may enhance or reduce the impact of ART on HIV incidence, in contrast to serosorting, which always leads to a lower impact of ART on HIV incidence. ART homophily and the emergence of ART clusters should be measured empirically and incorporated into more refined models used to plan and evaluate ART programmes. PMID:27657492

  20. The prospective validation of the Modified Physiological Triage Tool (MPTT): an evidence-based approach to major incident triage.

    Science.gov (United States)

    Vassallo, James; Horne, S; Smith, J E; Wallis, L A

    2017-12-01

    Triage is a key principle in the effective management of major incidents. There is limited evidence to support existing triage tools, with a number of studies demonstrating poor performance at predicting the need for a life-saving intervention. The Modified Physiological Triage Tool (MPTT) is a novel triage tool derived using logistic regression, and in retrospective data sets has shown optimum performance at predicting the need for life-saving intervention. Physiological data and interventions were prospectively collected for consecutive adult patients with trauma (>18 years) presenting to the emergency department at Camp Bastion, Afghanistan, between March and September 2011. Patients were considered priority 1 (P1) if they received one or more interventions from a previously defined list. Patients were triaged using existing triage tools and the MPTT. Performance was measured using sensitivity and specificity, and a McNemar test with Bonferroni calculation was applied for tools with similar performance. The study population comprised 357 patients, of whom 214 (59.9%) were classed as P1. The MPTT (sensitivity: 83.6%, 95% CI 78.0% to 88.3%; specificity: 51.0%, 95% CI 42.6% to 59.5%) outperformed all existing triage tools at predicting the need for life-saving intervention, with a 19.6% absolute reduction in undertriage compared with the existing Military Sieve. The improvement in undertriage comes at the expense of overtriage; rates of overtriage were 11.6% higher with the MPTT than the Military Sieve. Using a McNemar test, a statistically significant (ptriage tools at predicting the need for life-saving intervention, with the lowest rates of undertriage while maintaining acceptable levels of overtriage. Having now been validated on both military and civilian cohorts, we recommend that the major incident community consider adopting the MPTT for the purposes of primary triage. © Article author(s) (or their employer(s) unless otherwise stated in the text of the

  1. Modified Blumgart anastomosis with the "complete packing method" reduces the incidence of pancreatic fistula and complications after resection of the head of the pancreas.

    Science.gov (United States)

    Kojima, Toru; Niguma, Takefumi; Watanabe, Nobuyuki; Sakata, Taizo; Mimura, Tetsushige

    2018-03-26

    Postoperative pancreatic fistula (POPF) and its complications remain problems. This study evaluated combination treatment with modified Blumgart anastomosis and an original infection control method (complete packing method) following pancreatic head resection. This study included 374 consecutive patients who underwent pancreatic head resection: 103 patients underwent Cattell-Warren anastomosis (CWA); 170 patients underwent modified Kakita anastomosis (KA); and 101 patients underwent modified Blumgart anastomosis with the complete packing method (BAC). The outcomes of the KA and BAC groups were compared statistically. The POPF rate was significantly lower in the BAC group than in the KA group (28.8% vs 2.97%; p anastomosis and the complete packing method is a simple and useful method for reducing the incidence of POPF and postoperative complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Electrocardiographic spatial QRS-T angle and incident cardiovascular disease in HIV-infected patients (from the Strategies for the Management of Antiretroviral Therapy [SMART] study)

    DEFF Research Database (Denmark)

    Dawood, Farah Z; Khan, Faraaz; Roediger, Mollie P

    2013-01-01

    the baseline resting 12-lead electrocardiogram of 4,453 HIV-infected patients aged 43.5 ± 9.3 years from the Strategies for Management of Antiretroviral Therapy (SMART) trial. CVD events were identified during a median follow-up of 28.7 months. Quartiles of the spatial QRS-T angle was calculated for men...... risk of CVD events compared to a normal spatial QRS-T angle (hazard ratio 1.53, 95% confidence interval 1.07 to 2.17; p = 0.02). No interaction was seen by SMART trial arm (p value for interaction = 0.37) or gender (p value for interaction = 0.84). In conclusion, a widened spatial QRS-T angle...

  3. Development of Dynamic Loudspeakers Modified as Incident Pressure Sources for Noise Reductiuon in a Double Panel Structure

    NARCIS (Netherlands)

    Ho, J.H.; Berkhoff, A.P.

    2013-01-01

    This paper presents a modified loudspeaker source for decentralized feedback cavity control in a double panel structure to reduce the noise transmission. The double panel structure con-sists of two panels with air in between and offers the advantages of low weight, low sound transmission at high

  4. Development of dynamic loudspeakers modified as incident pressure sources for noise reduction in a double panel structure

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.; Crocker, Malcolm J.; Pawelczyk, Marek; Paosawatyanyong, Boonchoat

    2013-01-01

    This paper presents a modified loudspeaker source for decentralized feedback cavity control in a double panel structure to reduce the noise transmission. The double panel structure con-sists of two panels with air in between and offers the advantages of low weight, low sound transmission at high

  5. Three kinds of high-energy Pb ion tracks on the LiF crystal surface at grazing angles of incidence

    CERN Document Server

    Vorobyova, I V

    2002-01-01

    Tracks induced on a surface of a LiF crystal by Pb ions with energy of 4.46 MeV/u were studied by the method of shadow replica electron microscopy. The irradiation was carried out at angles of 0.5 deg. and 2 deg. relative to the surface plane of the crystal. Lengths and widths of three kinds of tracks were compared: (1) surface tracks which are formed on a pure crystal surface; (2) island tracks which are formed in an island film of gold (with island radius and separation of <=5 nm) deposited on the crystal surface prior to irradiation and (3) island tracks which are formed in the same island film pressed against the crystal surface by the carbon layer. It was established: (1) At angle of irradiation of 0.5 deg. , the surface track formation is initiated at a point where the ion has not yet crossed the crystal surface, but rather moves above the surface plane at a distance of <=1 nm. (2) When the island track is formed in the free island film, the islands completely removed from the track zone. (3) When...

  6. Catechol-o-methyltransferase gene polymorphism modifies the effect of coffee intake on incidence of acute coronary events.

    Directory of Open Access Journals (Sweden)

    Pertti Happonen

    Full Text Available BACKGROUND: The role of coffee intake as a risk factor for coronary heart disease (CHD has been debated for decades. We examined whether the relationship between coffee intake and incidence of CHD events is dependent on the metabolism of circulating catecholamines, as determined by functional polymorphism of the catechol-O-methyltransferase (COMT gene. METHODOLOGY/PRINCIPAL FINDINGS: In a cohort of 773 men who were 42 to 60 years old and free of symptomatic CHD at baseline in 1984-89, 78 participants experienced an acute coronary event during an average follow-up of 13 years. In logistic regression adjusting for age, smoking, family history of CHD, vitamin C deficiency, blood pressure, plasma cholesterol concentration, and diabetes, the odds ratio (90% confidence interval comparing heavy coffee drinkers with the low activity COMT genotype with those with the high activity or heterozygotic genotypes was 3.2 (1.2-8.4. Urinary adrenaline excretion increased with increasing coffee intake, being over two-fold in heavy drinkers compared with nondrinkers (p = 0.008 for trend. CONCLUSIONS/SIGNIFICANCE: Heavy coffee consumption increases the incidence of acute coronary events in men with low but not high COMT activity. Further studies are required to determine to which extent circulating catecholamines mediate the relationship between coffee intake and CHD.

  7. Large-angle production of charged pions with 3-12.9 GeV/c incident protons on nuclear targets

    CERN Document Server

    Catanesi, M.G.; Edgecock, R.; Ellis, Malcolm; Soler, F.J.P.; Gossling, C.; Bunyatov, S.; Krasnoperov, A.; Popov, B.; Serdiouk, V.; Tereschenko, V.; Di Capua, E.; Vidal-Sitjes, G.; Artamonov, A.; Giani, S.; Gilardoni, S.; Gorbunov, P.; Grant, A.; Grossheim, A.; Ivanchenko, A.; Ivanchenko, V.; Kayis-Topaksu, A.; Panman, J.; Papadopoulos, I.; Tcherniaev, E.; Tsukerman, I.; Veenhof, R.; Wiebusch, C.; Zucchelli, P.; Blondel, A.; Borghi, S.; Morone, M.C.; Prior, G.; Schroeter, R.; Meurer, C.; Gastaldi, U.; Mills, G.B.; Graulich, J.S.; Gregoire, G.; Bonesini, M.; Ferri, F.; Kirsanov, M.; Bagulya, A.; Grichine, V.; Polukhina, N.; Palladino, V.; Coney, L.; Schmitz, D.; Barr, G.; De Santo, A.; Bobisut, F.; Gibin, D.; Guglielmi, A.; Mezzetto, M.; Dumarchez, J.; Dore, U.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Booth, C.; Howlett, L.; Skoro, G.; Bogomilov, M.; Chizhov, M.; Kolev, D.; Tsenov, R.; Piperov, Stefan; Temnikov, P.; Apollonio, M.; Chimenti, P.; Giannini, G.; Burguet-Castell, J.; Cervera-Villanueva, A.; Gomez-Cadenas, J.J.; Martin-Albo, J.; Novella, P.; Sorel, M.; Tornero, A.

    2008-01-01

    Measurements of the double-differential charged pion production cross-section in the range of momentum 100 MeV/c < p < 800 MeV/c and angle 0.35 < \\theta < 2.15 rad in proton-beryllium, proton-carbon, proton-aluminium, proton-copper, proton-tin, proton-tantalum and proton-lead collisions are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN PS. The pions were produced by proton beams in a momentum range from 3 GeV/c to 12.9 GeV/c hitting a target with a thickness of 5% of a nuclear interaction length.

  8. Investigating Polymer–Metal Interfaces by Grazing Incidence Small-Angle X-Ray Scattering from Gradients to Real-Time Studies

    Directory of Open Access Journals (Sweden)

    Matthias Schwartzkopf

    2016-12-01

    Full Text Available Tailoring the polymer–metal interface is crucial for advanced material design. Vacuum deposition methods for metal layer coating are widely used in industry and research. They allow for installing a variety of nanostructures, often making use of the selective interaction of the metal atoms with the underlying polymer thin film. The polymer thin film may eventually be nanostructured, too, in order to create a hierarchy in length scales. Grazing incidence X-ray scattering is an advanced method to characterize and investigate polymer–metal interfaces. Being non-destructive and yielding statistically relevant results, it allows for deducing the detailed polymer–metal interaction. We review the use of grazing incidence X-ray scattering to elucidate the polymer–metal interface, making use of the modern synchrotron radiation facilities, allowing for very local studies via in situ (so-called “stop-sputter” experiments as well as studies observing the nanostructured metal nanoparticle layer growth in real time.

  9. RETRACTED: The influence of sand diameter and wind velocity on sand particle lift-off and incident angles in the windblown sand flux

    Science.gov (United States)

    Bo, Tian-Li; Zheng, Xiao-Jing; Duan, Shao-Zhen; Liang, Yi-Rui

    2013-05-01

    This article has been retracted: please see Elsevier Policy on Article Withdrawal. This article has been retracted at the request of the Editors-in-Chief. This article also contains significant similarity with parts of text, written by the same author(s), that have appeared in Tian-Li Bo, Xiao-Jing Zheng, Shao-Zhen Duan, Yi-Rui Liang, The influence of wind velocity and sand grain diameter on the falling velocities of sand particles, Powder Technology, Volume 241, June 2013, Pages 158-165. Tian-Li Bo, Xiao-Jing Zheng, Shao-Zhen Duan, Yi-Rui Liang, Analysis of sand particles' lift-off and incident velocities in wind-blown sand flux, Acta Mechanica Sinica, April 2013, Volume 29, Issue 2, pp 158-165. Tian-Li Bo, Xiao-Jing Zheng, Shao-Zhen Duan, Yi-Rui Liang, Influence of sand grain diameter and wind velocity on lift-off velocities of sand particles, The European Physical Journal E, May 2013, 36:50. Tian-Li Bo, Shao-Zhen Duan, Xiao-Jing Zheng, Yi-Rui Liang, The influence of sand bed temperature on lift-off and falling parameters in windblown sand flux, Geomorphology, Volume 204, 1 January 2014, Pages 477-484. The scientific community takes a very strong view on this matter and apologies are offered to readers of the journal that this was not detected during the submission process.

  10. Evidence for evanescent waves at interfaces in a high-index prism/liquid-crystal-Au-NPs/glass/air structure and effects of relative concentration of gold nanoparticles, wavelength, polarization, and incident angle of the laser beam

    Science.gov (United States)

    Tiwari, Kunal; Singh, Ankit; Sharma, Suresh

    2011-10-01

    Incorporation of relatively small concentrations of gold nanoparticles (Au NPs) in a polymer-dispersed liquid crystal (PDLC) is known to lower the operating threshold voltage and increase optical transmission through the device.ootnotetextA. Hinojosa and S. C. Sharma, Applied Physics Letters, 97, 081114 (2010) In order to understand whether there is an interplay between the localized surface plasmon resonance at Au-NPs-dielectric interfaces and the electro-optical properties of PDLC devices, we have investigated propagation of light through a high-index prism/liquid-crystal-Au-NPs/glass/air structure by using Kretschmann geometry as functions of concentration of Au NPs in the liquid crystal, and the wavelength, polarization, and angle of incidence of the laser beam. We will discuss to what extent the results of these experiments support an interplay between the localized surface plasmon resonance at NPs/dielectric interfaces and optical propagation through the above-described structure.

  11. Crystal structure analysis in solution-processed uniaxially oriented polycrystalline thin film of non-peripheral octahexyl phthalocyanine by grazing incidence wide-angle x-ray scattering techniques

    Science.gov (United States)

    Ohmori, Masashi; Uno, Takashi; Nakatani, Mitsuhiro; Nakano, Chika; Fujii, Akihiko; Ozaki, Masanori

    2016-10-01

    Uniaxially oriented thin films of metal-free non-peripherally octahexyl-substituted phthalocyanine (C6PcH2), which exhibits high carrier mobility, have been fabricated by the bar-coating technique, which is a simple solution process. The molecular orientation and molecular steps in the thin film were observed by the polarized spectroscopy and the atomic force microscopy, respectively. The three-dimensional molecular packing structure in the thin film was investigated by the grazing incidence wide-angle X-ray scattering technique with an in-plane sample rotation. The crystal orientation was clarified, and the three-dimensional molecular packing structure of the thin film was found to match the single crystal structure. Moreover, the X-ray diffraction patterns of the oriented thin films were simulated by using the lattice parameters of C6PcH2 single crystal to reproduce the observed X-ray diffraction patterns.

  12. Scoliosis angle

    International Nuclear Information System (INIS)

    Marklund, T.

    1978-01-01

    The most commonly used methods of assessing the scoliotic deviation measure angles that are not clearly defined in relation to the anatomy of the patient. In order to give an anatomic basis for such measurements it is proposed to define the scoliotic deviation as the deviation the vertebral column makes with the sagittal plane. Both the Cobb and the Ferguson angles may be based on this definition. The present methods of measurement are then attempts to measure these angles. If the plane of these angles is parallel to the film, the measurement will be correct. Errors in the measurements may be incurred by the projection. A hypothetical projection, called a 'rectified orthogonal projection', is presented, which correctly represents all scoliotic angles in accordance with these principles. It can be constructed in practice with the aid of a computer and by performing measurements on two projections of the vertebral column; a scoliotic curve can be represented independent of the kyphosis and lordosis. (Auth.)

  13. Ion desorption from solid surfaces under slow (KeV) and fast (MeV) ion sputtering. Influence of the charge state and of the incidence angle on the input channel

    International Nuclear Information System (INIS)

    Joret, H.

    1990-06-01

    Solid surfaces of organic and inorganic materials have been bombarded by fast heavy ions (several MeV). It is shown that the charge state of the projectile has a strong influence on the atomic and molecular ion desorption yield. Experimental studies proved that molecular ions can be emitted intact from deep layers underneath the surface (volume emission) with the existence of a crater emission. On the other hand light ions like H(+), H(+)-2, H(+)-3 are emitted from the surface of the solid in a time around 10 -16 second. The H(+) depends on the incident charge state g-i. When using slow ions (keV) the same dependence was observed for the first time and compared to the fast ion results. The equilibrum charge state of fast ions passing through solids was measured. The influence of the angle of incidence was investigated. Langmuir-Blodgett films of fatty acid were used. A geometrical model is developed for the 50 angstroms layer [fr

  14. Incidência de glaucoma agudo primário no Serviço de Glaucoma do Hospital São Geraldo Incidence of primary angle-closure glaucoma in the Glaucoma Service of the São Geraldo Hospital

    Directory of Open Access Journals (Sweden)

    Rafael Vidal Mérula

    2008-06-01

    Full Text Available OBJETIVOS: Determinar a incidência do glaucoma agudo primário no Serviço de Glaucoma do Hospital São Geraldo; estabelecer o perfil destes pacientes e identificar possíveis fatores de risco. MÉTODOS: Estudo transversal. Período de análise: setembro/2005 a agosto/2006. Inclusão: diagnóstico de glaucoma agudo primário. Exclusão: presença de catarata que acarrete baixa acuidade visual ou miopização, glaucomas secundários, íris em platô. Foram avaliados: número de atendimentos, incidência de glaucoma agudo primário, idade, sexo, raça, história familiar de glaucoma, ceratometria, e dados biométricos. RESULTADOS: Dentre 879 pacientes atendidos, 20 (2,3% tiveram o diagnóstico de glaucoma agudo primário, desse modo, a incidência de glaucoma agudo primário foi de 22,7 por 1000 atendimentos. Dos pacientes com glaucoma agudo primário: 6 (30,0% eram do sexo masculino e 14 (70,0% feminino; a idade variou de 40 a 73 anos (média: 60,4 ± 8,1 anos; 12 (60,0% eram leucodérmicos e 8 (40,0% feodérmicos; 5 (25,0% com história familiar positiva para glaucoma. O risco relativo para o sexo feminino foi de 1,44 (IC 95%. Onze (55,0% pacientes tiveram glaucoma agudo primário no olho direito e 9 (45,0% no esquerdo. Não houve diferença estatisticamente significativa na comparação dos parâmetros biométricos e ceratometria entre os olhos afetados e os contralaterais. CONCLUSÕES: A incidência de glaucoma agudo primário no Serviço de Glaucoma do Hospital São Geraldo foi de 22,7 por 1000 atendimentos, sendo mais freqüente em mulheres, leucodérmicas, com história familiar negativa para glaucoma e média de idade de 60,4 anos. Os olhos afetados e olhos contralaterais foram semelhantes nos parâmetros biométricos.PURPOSE: To determine the incidence of the primary angle-closure glaucoma at the Glaucoma Service of São Geraldo Hospital, to establish the profile of these patients and to identify the possible risk factors. METHODS

  15. Retrieval of Melt Ponds on Arctic Multiyear Sea Ice in Summer from TerraSAR-X Dual-Polarization Data Using Machine Learning Approaches: A Case Study in the Chukchi Sea with Mid-Incidence Angle Data

    Directory of Open Access Journals (Sweden)

    Hyangsun Han

    2016-01-01

    Full Text Available Melt ponds, a common feature on Arctic sea ice, absorb most of the incoming solar radiation and have a large effect on the melting rate of sea ice, which significantly influences climate change. Therefore, it is very important to monitor melt ponds in order to better understand the sea ice-climate interaction. In this study, melt pond retrieval models were developed using the TerraSAR-X dual-polarization synthetic aperture radar (SAR data with mid-incidence angle obtained in a summer multiyear sea ice area in the Chukchi Sea, the Western Arctic, based on two rule-based machine learning approaches—decision trees (DT and random forest (RF—in order to derive melt pond statistics at high spatial resolution and to identify key polarimetric parameters for melt pond detection. Melt ponds, sea ice and open water were delineated from the airborne SAR images (0.3-m resolution, which were used as a reference dataset. A total of eight polarimetric parameters (HH and VV backscattering coefficients, co-polarization ratio, co-polarization phase difference, co-polarization correlation coefficient, alpha angle, entropy and anisotropy were derived from the TerraSAR-X dual-polarization data and then used as input variables for the machine learning models. The DT and RF models could not effectively discriminate melt ponds from open water when using only the polarimetric parameters. This is because melt ponds showed similar polarimetric signatures to open water. The average and standard deviation of the polarimetric parameters based on a 15 × 15 pixel window were supplemented to the input variables in order to consider the difference between the spatial texture of melt ponds and open water. Both the DT and RF models using the polarimetric parameters and their texture features produced improved performance for the retrieval of melt ponds, and RF was superior to DT. The HH backscattering coefficient was identified as the variable contributing the most, and its

  16. Small-angle neutron scattering study of activated carbon cloth and ammonium persulfate-modified activated carbon cloth: Effect of oxygen content

    International Nuclear Information System (INIS)

    Pendleton, Phillip; Chen Lin

    2006-01-01

    Small-angle neutron scattering (SANS) patterns of as-received, oxidized, and thermally reduced FM1/250 activated carbon cloth (ACC) samples are compared to determine the effects of surface chemistry on scattering. Porosity analyses show minimal effect on pore size distribution from oxidation, but an increase in micropore volume on heat treatment. SANS suggests an increase in localized order within the treated samples when compared with graphite cloth patterns. The ACC exhibits Porod scattering at q-ranges -1 ; the graphite cloth exhibits the same at q-ranges>1.0 nm -1 . A cylindrical model reproduces the scattering patterns in the micropore equivalent dimensions, q>0.5 nm -1

  17. Surface morphology of vacuum-evaporated pentacene film on Si substrate studied by in situ grazing-incidence small-angle X-ray scattering: I. The initial stage of formation of pentacene film

    Science.gov (United States)

    Hirosawa, Ichiro; Watanabe, Takeshi; Koganezawa, Tomoyuki; Kikuchi, Mamoru; Yoshimoto, Noriyuki

    2018-03-01

    The progress of the surface morphology of a growing sub-monolayered pentacene film on a Si substrate was studied by in situ grazing-incidence small angle X-ray scattering (GISAXS). The observed GISAXS profiles did not show sizes of pentacene islands but mainly protuberances on the boundaries around pentacene film. Scattering of X-ray by residual pits in the pentacene film was also detected in the GISAXS profiles of an almost fully covered film. The average radius of pentacene protuberances increased from 13 to 24 nm as the coverage increased to 0.83 monolayer, and the most frequent radius was almost constant at approximately 9 nm. This result suggests that the population of larger protuberances increase with increasing lengths of boundaries of the pentacene film. It can also be considered that the detected protuberances were crystallites of pentacene, since the average size of protuberances was nearly equal to crystallite sizes of pentacene films. The almost constant characteristic distance of 610 nm and amplitudes of pair correlation functions at low coverages suggest that the growth of pentacene films obeyed the diffusion-limited aggregation (DLA) model, as previously reported. It is also considered that the sites of islands show a triangular distribution for small variations of estimated correlation distances.

  18. A customizable software for fast reduction and analysis of large X-ray scattering data sets: applications of the new DPDAK package to small-angle X-ray scattering and grazing-incidence small-angle X-ray scattering.

    Science.gov (United States)

    Benecke, Gunthard; Wagermaier, Wolfgang; Li, Chenghao; Schwartzkopf, Matthias; Flucke, Gero; Hoerth, Rebecca; Zizak, Ivo; Burghammer, Manfred; Metwalli, Ezzeldin; Müller-Buschbaum, Peter; Trebbin, Martin; Förster, Stephan; Paris, Oskar; Roth, Stephan V; Fratzl, Peter

    2014-10-01

    X-ray scattering experiments at synchrotron sources are characterized by large and constantly increasing amounts of data. The great number of files generated during a synchrotron experiment is often a limiting factor in the analysis of the data, since appropriate software is rarely available to perform fast and tailored data processing. Furthermore, it is often necessary to perform online data reduction and analysis during the experiment in order to interactively optimize experimental design. This article presents an open-source software package developed to process large amounts of data from synchrotron scattering experiments. These data reduction processes involve calibration and correction of raw data, one- or two-dimensional integration, as well as fitting and further analysis of the data, including the extraction of certain parameters. The software, DPDAK (directly programmable data analysis kit), is based on a plug-in structure and allows individual extension in accordance with the requirements of the user. The article demonstrates the use of DPDAK for on- and offline analysis of scanning small-angle X-ray scattering (SAXS) data on biological samples and microfluidic systems, as well as for a comprehensive analysis of grazing-incidence SAXS data. In addition to a comparison with existing software packages, the structure of DPDAK and the possibilities and limitations are discussed.

  19. Probing the surface microstructure of layer-by-layer self-assembly chitosan/poly(L-glutamic acid) multilayers: A grazing-incidence small-angle X-ray scattering study

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Nie; Yang, Chunming, E-mail: yangchunming@sinap.ac.cn; Wang, Yuzhu; Zhao, Binyu; Bian, Fenggang; Li, Xiuhong; Wang, Jie, E-mail: wangjie@sinap.ac.cn

    2016-01-01

    This study characterized the surface structure of layer-by-layer self-assembly chitosan/poly(L-glutamic acid) multilayers through grazing-incidence small-angle X-ray scattering (GISAXS), X-ray reflectivity (XRR), and atomic force microscopy (AFM). A weakly long-period ordered structure along the in-plane direction was firstly observed in the polyelectrolyte multilayer by the GISAXS technique. This structure can be attributed to the specific domains on the film surface. In the domain, nanodroplets that were formed by polyelectrolyte molecules were orderly arranged along the free surface of the films. This ordered structure gradually disappeared with the increasing bilayer number because of the complex merging behavior of nanodroplets into large islands. Furthermore, resonant diffuse scattering became evident in the GISAXS patterns as the number of bilayers in the polyelectrolyte multilayer was increased. Notably, the lateral cutoff length of resonant diffuse scattering for these polyelectrolyte films was comparable with the long-period value of the ordered nanodroplets in the polyelectrolyte multilayer. Therefore, the nanodroplets could be considered as a basic transmission unit for structure propagation from the inner interface to the film surface. It suggests that the surface structure with length scale larger than the size of nanodroplets was partially complicated from the interface structure near the substrate, but surface structure smaller than the cutoff length was mainly depended on the conformation of nanodroplets. - Highlights: • The growth of ordered nanodroplets in PEMs was characterized by the GISAXS technique. • The basic transmission units for structure propagation within PEMs were nanodroplets. • High-performance of wave-guiding devices prepared by PEMs was predicted.

  20. Observations at large zenith angles

    CERN Document Server

    Schroeder, F

    2000-01-01

    Cherenkov telescope observations at zenith angles >70 deg. are capable of providing large collection areas for high energy gamma-induced air showers. In order to provide a full Monte Carlo simulation of the large zenith angle observations the air shower simulation code CORSIKA was modified to treat particles in a curved geometry. First results of studies with the stand alone telescope HEGRA CT1 are presented.

  1. Assessment of temperature effect on childhood hand, foot and mouth disease incidence (0-5years) and associated effect modifiers: A 17 cities study in Shandong Province, China, 2007-2012.

    Science.gov (United States)

    Zhu, Lin; Wang, Xianjun; Guo, Yuming; Xu, Jing; Xue, Fuzhong; Liu, Yanxun

    2016-05-01

    Previous studies examining temperature-disease associations of hand, foot and mouth disease (HFMD) mainly focused on a single city. The results demonstrated great heterogeneity. A multi-city study is necessary to better understand temperature risk on the childhood incidence of HFMD and the associated modified factors. To assess the effect of ambient temperature on childhood HFMD incidence and explore the potential associated effect modifiers in the study area. Daily morbidity data and meteorological variables of the 17 cities were collected for the period from 2007 to 2012. Distributed lag non-linear model (DLNM) was used to estimate city-specific effects of temperature on HFMD incidence. A multivariate meta-analysis was then applied to pool the estimated city-specific effect. Potential effect modifiers were included in the multivariate meta-regression as meta-predictors. A total of 504,017 childhood HFMD cases were included in the study. The high-incidence period of HFMD was detected in late spring and early summer (April to June). The temperature-disease associations of the 17 cities demonstrated great heterogeneity and the pooled exposure-response curve was an approximately inverted V-shape. Regional indicator, numbers of healthcare institution and annual household income were considered as associated modifiers. Our findings can provide a practical reference for the early warning and intervention strategies of HFMD. Different temperature-disease associations among different regions should be considered when formulating and optimizing public health policy. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Surface morphological changes on the human dental enamel and cement after the Er:YAG laser irradiation at different incidence angles; Avaliacao morfologica das superficies do esmalte e do cimento dental apos a irradiacao do laser de Er:YAG em diferentes angulacoes

    Energy Technology Data Exchange (ETDEWEB)

    Tannous, Jose Trancoso

    2001-07-01

    This is a morphological analysis study through SEM of the differences of the laser tissue interaction as a function of the laser beam irradiation angle, under different parameters of energy. Fourteen freshly extracted molars stored in a 0,9% sodium chloride solution were divided in seven pairs and were irradiated with 100, 200, 300, 400, 500, 600 and 700 mJ per pulse, respectively. Each sample received three enamel irradiations and three cement irradiations, either in the punctual or in the contact mode, one near to the other, with respectively 30, 45 and 90 inclinations degrees of dental surface-laser-beam incidence. Four Er:YAG pulses (2,94 {mu}m, 7-20 Hz, 0,1-1 J energy/pulse - Opus 20 - Opus Dent) with water cooling system (0,4 ml/s) were applied. After the laser irradiation the specimens were analysed through scanning electron microscope (SEM). The results were analysed by SEM micrographs showing a great difference on the laser tissue interaction characteristics as a function of the irradiation angle of the laser beam. All the observations led to conclude that, considering the laser parameters used, the incidence angle variation is a very important parameter regarding the desired morphological effects. This represents an extremely relevant detail on the technical description of the Er:YAG laser irradiation protocols on dental tissues. (author)

  3. Glancing angle x-ray studies of oxide films

    International Nuclear Information System (INIS)

    Davenport, A.J.; Isaacs, H.S.

    1989-01-01

    High brightness synchrotron radiation incident at glancing angles has been used to study inhibiting species present in low concentrations in oxide films on aluminum. Glancing incident angle fluorescence measurements give surface-sensitive information on the valence state of elements from the shape of the x-ray absorption edge. Angle-resolved measurements show the depth distribution of the species present. 15 refs., 4 figs

  4. A modified Mediterranean diet score is associated with a lower risk of incident metabolic syndrome over 25 years among young adults: the CARDIA (Coronary Artery Risk Development in Young Adults) study.

    Science.gov (United States)

    Steffen, Lyn M; Van Horn, Linda; Daviglus, Martha L; Zhou, Xia; Reis, Jared P; Loria, Catherine M; Jacobs, David R; Duffey, Kiyah J

    2014-11-28

    The Mediterranean diet has been reported to be inversely associated with incident metabolic syndrome (MetSyn) among older adults; however, this association has not been studied in young African American and white adults. The objective of the present study was to evaluate the association of a modified Mediterranean diet (mMedDiet) score with the 25-year incidence of the MetSyn in 4713 African American and white adults enrolled in the Coronary Artery Risk Development in Young Adults (CARDIA) study. A diet history questionnaire was used to assess dietary intake at baseline, year 7 and year 20 and a mMedDiet score was created. Cardiovascular risk factors were measured at multiple examinations over 25 years. The MetSyn was defined according to the National Cholesterol Education Program Adult Treatment Panel III (ATP III) criteria. Cox proportional-hazards regression analysis was use to evaluate associations for incident MetSyn across the mMedDiet score categories adjusting for demographic characteristics, lifestyle factors and BMI. Higher mMedDiet scores represented adherence to a dietary pattern rich in fruit, vegetables, whole grains, nuts and fish, but poor in red and processed meat and snack foods. The incidence of MetSyn components (abdominal obesity, elevated TAG concentrations and low HDL-cholesterol concentrations) was lower in those with higher mMedDiet scores than in those with lower scores. Furthermore, the incidence of the MetSyn was lower across the five mMedDiet score categories; the hazard ratios and 95 % CI from category 1 to category 5 were 1·0; 0·94 (0·76, 1·15); 0·84 (0·68, 1·04); 0·73 (0·58, 0·92); and 0·72 (0·54, 0·96), respectively (P trend= 0·005). These findings suggest that the risk of developing the MetSyn is lower when consuming a diet rich in fruit, vegetables, whole grains, nuts and fish.

  5. Prompt angle measurements with large aperture scintillators

    International Nuclear Information System (INIS)

    Schneid, E.J.

    1976-01-01

    A technique is described for the measurement of particle trajectory angle through a pair of scintillator tiles. Signal processing provides an analog signal proportional to the tangent of the angle between the particle trajectory and the axis normal to the pair of tiles. This signal is readily available for use in fast decision logic if required: i.e., sorting energy loss signals from the tiles according to geometrical factors or restricting the events to be analyzed on the basis of incident direction

  6. Contact Angle Goniometer

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...

  7. Viscous flow solutions for slender bodies of revolution at incidence

    Science.gov (United States)

    Vatsa, Veer N.

    1991-01-01

    Flow over slender prolate spheroids at incidence is examined. The incidence angle is chosen high enough to cause streamwise separation of the flow in addition to crossflow separation generally observed at lower incidence angles. The freestream Mach number for the cases investigated here is subsonic, thus precluding the use of parabolized procedures. Laminar, transitional and turbulent flow cases are investigated.

  8. Side-pumped Nd:YVO{sub 4} cw laser with grazing-incidence small angle configuration; Laser de Nd:YVO{sub 4} bombeado transversalmente em configuracao com angulo rasante interno

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Fabiola de Almeida

    2006-07-01

    Within the existing variety of laser cavity geometries and gain materials there is one combination that is particularly interesting because of its reduced complexity and high efficiency: the edge-pumped slab-laser using grazing-incidence geometry and a gain media with a very high pump absorption cross-section. In this work we studied a diode side-pumped Nd:YVO{sub 4} cw laser. We describe a single and a multiple bounce laser configurations. We demonstrate 22 W of multimode output power for 35 watts of pump power with a single pass through the gain media. A high optical-to-optical conversion efficiency of 63% and a slope efficiency of 74% with a very compact and simple Nd:YVO{sub 4} cavity that uses joint stability zones was achieved. The beam quality was M{sup 2} = 26 x 11 in the horizontal and vertical direction, respectively. With a double pass configuration we achieved 17 watts with a better beam quality of M{sup 2} = 3,4 x 3,7, in the horizontal and vertical direction, respectively. (author)

  9. Small angle neutron scattering

    Directory of Open Access Journals (Sweden)

    Cousin Fabrice

    2015-01-01

    Full Text Available Small Angle Neutron Scattering (SANS is a technique that enables to probe the 3-D structure of materials on a typical size range lying from ∼ 1 nm up to ∼ a few 100 nm, the obtained information being statistically averaged on a sample whose volume is ∼ 1 cm3. This very rich technique enables to make a full structural characterization of a given object of nanometric dimensions (radius of gyration, shape, volume or mass, fractal dimension, specific area… through the determination of the form factor as well as the determination of the way objects are organized within in a continuous media, and therefore to describe interactions between them, through the determination of the structure factor. The specific properties of neutrons (possibility of tuning the scattering intensity by using the isotopic substitution, sensitivity to magnetism, negligible absorption, low energy of the incident neutrons make it particularly interesting in the fields of soft matter, biophysics, magnetic materials and metallurgy. In particular, the contrast variation methods allow to extract some informations that cannot be obtained by any other experimental techniques. This course is divided in two parts. The first one is devoted to the description of the principle of SANS: basics (formalism, coherent scattering/incoherent scattering, notion of elementary scatterer, form factor analysis (I(q→0, Guinier regime, intermediate regime, Porod regime, polydisperse system, structure factor analysis (2nd Virial coefficient, integral equations, characterization of aggregates, and contrast variation methods (how to create contrast in an homogeneous system, matching in ternary systems, extrapolation to zero concentration, Zero Averaged Contrast. It is illustrated by some representative examples. The second one describes the experimental aspects of SANS to guide user in its future experiments: description of SANS spectrometer, resolution of the spectrometer, optimization of

  10. Grazing-angle incidence X-ray diffraction by Si sub 1 sub - subalpha sub ( sub x sub ) Ge subalpha sub ( sub x sub ) thin layer if the composition coefficient alpha(x) is varying harmonically along the flat entrance surface

    CERN Document Server

    Bezirganyan, P A; Bezirganyan, S E; Bezirganyan, H A; Hovnanyan, K O

    2003-01-01

    Presented theoretical paper concerns the investigation of a principal possibility of the Grazing-angle incidence hard and soft X-ray diffraction (GIXD) owing to long-period harmonic variations of the composition coefficient of the strained or relaxed crystalline, as well as amorphous SiGe layer grown on a thick silicon perfect-crystal substrate. The evaluation of the coherent part of X-radiation scattered by mentioned SiGe layer is pointed out the possibility of the direct GIXD experimental investigations of the long-period structured intermediate transformation states of SiGe layer, which are emerging due to periodicity of the strain field along the substrate-layer boundary.

  11. Wheelchair incidents

    NARCIS (Netherlands)

    Drongelen AW van; Roszek B; Hilbers-Modderman ESM; Kallewaard M; Wassenaar C; LGM

    2002-01-01

    This RIVM study was performed to gain insight into wheelchair-related incidents with powered and manual wheelchairs reported to the USA FDA, the British MDA and the Dutch Center for Quality and Usability Research of Technical Aids (KBOH). The data in the databases do not indicate that incidents with

  12. The HBN Angle

    Directory of Open Access Journals (Sweden)

    Harsh Bhagvatiprasad Dave

    2015-01-01

    Full Text Available Aim: The purpose of this study was to establish a new cephalometric measurement, named the Harsh Bhagvatiprasad Nita angle (HBN, to assess the sagittal jaw relationship with accuracy and reproducibility. Materials and Methods: Three hundred pretreatment lateral cephalograms (100 each of Class I, II, and III were taken from the Department of Orthodontics and Dentofacial Orthopedics of Rajasthan Dental College and Hospital, Jaipur (Rajasthan and were subdivided into skeletal Class I, II, and III based on ANB, Wits appraisal, and Beta angle. This angle uses 3 skeletal landmarks the "C" (apparent axis of the condyle, "M" (midpoint of the premaxilla, and "G" (center of the largest circle that is tangent to the internal inferior, anterior, and posterior surfaces of the mandibular symphysis. Results: The result of the mean and standard deviation for the HBN angle were calculated in all three skeletal groups. After using one-way analysis of variance and post-hoc multiple comparisons by using Tukey′s honestly significant difference, homogeneous subsets, receiver operating characteristics (ROC curve - to differentiate Class II with Class I, ROC curve - to differentiate Class III with Class I, Reliability analysis with interclass correlation of HBN angle with other angles, we obtained results that showed that a patient with a HBN angle 40° and 46° can be considered to have a Class I skeletal pattern. Conclusions: A new angle, the HBN angle, was developed as a diagnostic aid to evaluate the sagittal jaw relationship more consistently. HBN angle 40° and 46° can be considered to have a Class I skeletal pattern, a more acute HBN angle indicates a Class II skeletal pattern, and a more obtuse HBN angle indicates a Class III skeletal pattern.

  13. Angle-selective all-dielectric Huygens’ metasurfaces

    Science.gov (United States)

    Arslan, D.; Chong, K. E.; Miroshnichenko, A. E.; Choi, D.-Y.; Neshev, D. N.; Pertsch, T.; Kivshar, Y. S.; Staude, I.

    2017-11-01

    We experimentally and numerically study the angularly resolved transmission properties of dielectric metasurfaces consisting of silicon nanodisks which support electric and magnetic dipolar Mie-type resonances in the near-infrared spectral range. First, we concentrate on Huygens’ metasurfaces which are characterised by a spectral overlap of the fundamental electric and magnetic dipole resonances of the silicon nanodisks at normal incidence. Huygens’ metasurfaces exhibit a high transmitted intensity over the spectral width of the resonances due to impedance matching, while the transmitted phase shows a variation of 2π as the wavelength is swept across the width of the resonances. We observe that the transmittance of the Huygens’ metasurfaces depends on the incidence angle and is sensitive to polarisation for non-normal incidence. As the incidence angle is increased starting from normal incidence, the two dipole resonances are shifted out of the spectral overlap and the resonant features appear as pronounced transmittance minima. Next, we consider a metasurface with an increased nanodisk radius as compared to the Huygens’ metasurface, which supports spectrally separate electric and magnetic dipole resonances at normal incidence. We show that for TM polarisation, we can shift the resonances of this metasurface into spectral overlap and regain the high resonant transmittance characteristic of Huygens’ metasurfaces at a particular incidence angle. Furthermore, both metasurfaces are demonstrated to reject all TM polarised light incident under angles other than the design overlap angle at their respective operation frequency. Our experimental observations are in good qualitative agreement with numerical calculations.

  14. Spondylolysis and the sacro-horizontal angle in athletes

    International Nuclear Information System (INIS)

    Swaerd, L.; Hellstroem, M.; Jacobsson, B.; Peterson, L.; Sahlgrenska Sjukhuset, Goeteborg; King Faisal Specialist Hospital and Research Centre, Riyadh

    1989-01-01

    The frequency of spondylolysis and the relationship between spondylolysis and the sacro-horizontal angle in 143 athletes and 30 non-athletes is reported. Athletes had a larger sacro-horizontal angle than non-athletes. The sacro-horizontal angle was larger in athletes with spondylolysis as compared with those without. An increased incidence of spondylolysis with an increased angle was demonstrated. It is suggested that an increased sacro-horizontal angle may predispose to spondylolysis, especially in combination with the high mechanical loads sustained in certain sports. (orig.)

  15. Spondylolysis and the sacro-horizontal angle in athletes

    Energy Technology Data Exchange (ETDEWEB)

    Swaerd, L.; Hellstroem, M.; Jacobsson, B.; Peterson, L. (Oestra Sjukhuset, Goeteborg (Sweden). Dept. of Orthopaedics; Sahlgrenska Sjukhuset, Goeteborg (Sweden). Dept. of Diagnostic Radiology; King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia). Dept. of Radiology)

    The frequency of spondylolysis and the relationship between spondylolysis and the sacro-horizontal angle in 143 athletes and 30 non-athletes is reported. Athletes had a larger sacro-horizontal angle than non-athletes. The sacro-horizontal angle was larger in athletes with spondylolysis as compared with those without. An increased incidence of spondylolysis with an increased angle was demonstrated. It is suggested that an increased sacro-horizontal angle may predispose to spondylolysis, especially in combination with the high mechanical loads sustained in certain sports. (orig.).

  16. Reading Angles in Maps

    Science.gov (United States)

    Izard, Véronique; O'Donnell, Evan; Spelke, Elizabeth S.

    2014-01-01

    Preschool children can navigate by simple geometric maps of the environment, but the nature of the geometric relations they use in map reading remains unclear. Here, children were tested specifically on their sensitivity to angle. Forty-eight children (age 47:15-53:30 months) were presented with fragments of geometric maps, in which angle sections…

  17. Optimal reconstruction angles

    International Nuclear Information System (INIS)

    Cook, G.O. Jr.; Knight, L.

    1979-07-01

    The question of optimal projection angles has recently become of interest in the field of reconstruction from projections. Here, studies are concentrated on the n x n pixel space, where literative algorithms such as ART and direct matrix techniques due to Katz are considered. The best angles are determined in a Gauss--Markov statistical sense as well as with respect to a function-theoretical error bound. The possibility of making photon intensity a function of angle is also examined. Finally, the best angles to use in an ART-like algorithm are studied. A certain set of unequally spaced angles was found to be preferred in several contexts. 15 figures, 6 tables

  18. Photoelectric angle converter

    Science.gov (United States)

    Podzharenko, Volodymyr A.; Kulakov, Pavlo I.

    2001-06-01

    The photo-electric angle transmitter of rotation is offered, at which the output voltage is linear function of entering magnitude. In a transmitter the linear phototransducer is used on the basis of pair photo diode -- operating amplifier, which output voltage is linear function of the area of an illuminated photosensitive stratum, and modulator of a light stream of the special shape, which ensures a linear dependence of this area from an angle of rotation. The transmitter has good frequent properties and can be used for dynamic measurements of an angular velocity and angle of rotation, in systems of exact drives and systems of autocontrol.

  19. Incidents analysis

    International Nuclear Information System (INIS)

    Francois, P.

    1996-01-01

    We undertook a study programme at the end of 1991. To start with, we performed some exploratory studies aimed at learning some preliminary lessons on this type of analysis: Assessment of the interest of probabilistic incident analysis; possibility of using PSA scenarios; skills and resources required. At the same time, EPN created a working group whose assignment was to define a new approach for analysis of incidents on NPPs. This working group gave thought to both aspects of Operating Feedback that EPN wished to improve: Analysis of significant incidents; analysis of potential consequences. We took part in the work of this group, and for the second aspects, we proposed a method based on an adaptation of the event-tree method in order to establish a link between existing PSA models and actual incidents. Since PSA provides an exhaustive database of accident scenarios applicable to the two most common types of units in France, they are obviously of interest for this sort of analysis. With this method we performed some incident analyses, and at the same time explores some methods employed abroad, particularly ASP (Accident Sequence Precursor, a method used by the NRC). Early in 1994 EDF began a systematic analysis programme. The first, transient phase will set up methods and an organizational structure. 7 figs

  20. SCATTTERING OF HIGH-ENERGY PARTICLES AT A COLLISIONLESS SHOCK FRONT: DEPENDENCE ON THE SHOCK ANGLE

    Energy Technology Data Exchange (ETDEWEB)

    Gedalin, M. [Department of Physics, Ben-Gurion University of the Negev, Beer-Sheva (Israel); Dröge, W.; Kartavykh, Y. Y., E-mail: gedalin@bgu.ac.il [Institute for Theoretical Physics and Astrophysics, University of Würzburg, Würzburg (Germany)

    2015-07-10

    Many shock acceleration theories deal with gyrophase-averaged particle distributions that depend only on the energy and pitch angle of the particles. Diffusive shock acceleration includes shock crossing as a necessary component. As long as the shock width is much smaller than the mean free path of a particle, the crossing is governed by the macroscopic fields inside the transition layer. The dynamics of high-energy particles in these fields is non-adiabatic and gyrophase dependent. The magnetic moment is not conserved in a wide range of shock angles, nor is the condition of reflection determined by the magnetic bottle relation. Instead, for a pitch angle and unknown gyrophase of an incident particle there is a finite probability of reflection. This probability varies between zero and unity in a wide range of pitch angles. In this work we investigate how the matching conditions at the shock front could be modified with the gyrophase dependence taken into account, e.g., in the form of the scattering probabilities.

  1. SCATTTERING OF HIGH-ENERGY PARTICLES AT A COLLISIONLESS SHOCK FRONT: DEPENDENCE ON THE SHOCK ANGLE

    International Nuclear Information System (INIS)

    Gedalin, M.; Dröge, W.; Kartavykh, Y. Y.

    2015-01-01

    Many shock acceleration theories deal with gyrophase-averaged particle distributions that depend only on the energy and pitch angle of the particles. Diffusive shock acceleration includes shock crossing as a necessary component. As long as the shock width is much smaller than the mean free path of a particle, the crossing is governed by the macroscopic fields inside the transition layer. The dynamics of high-energy particles in these fields is non-adiabatic and gyrophase dependent. The magnetic moment is not conserved in a wide range of shock angles, nor is the condition of reflection determined by the magnetic bottle relation. Instead, for a pitch angle and unknown gyrophase of an incident particle there is a finite probability of reflection. This probability varies between zero and unity in a wide range of pitch angles. In this work we investigate how the matching conditions at the shock front could be modified with the gyrophase dependence taken into account, e.g., in the form of the scattering probabilities

  2. Angles in hyperbolic lattices

    DEFF Research Database (Denmark)

    Risager, Morten S.; Södergren, Carl Anders

    2017-01-01

    It is well known that the angles in a lattice acting on hyperbolic n -space become equidistributed. In this paper we determine a formula for the pair correlation density for angles in such hyperbolic lattices. Using this formula we determine, among other things, the asymptotic behavior of the den......It is well known that the angles in a lattice acting on hyperbolic n -space become equidistributed. In this paper we determine a formula for the pair correlation density for angles in such hyperbolic lattices. Using this formula we determine, among other things, the asymptotic behavior...... of the density function in both the small and large variable limits. This extends earlier results by Boca, Pasol, Popa and Zaharescu and Kelmer and Kontorovich in dimension 2 to general dimension n . Our proofs use the decay of matrix coefficients together with a number of careful estimates, and lead...

  3. Ultra small angle scattering versus diffraction

    Science.gov (United States)

    Ebrahimi, O.; Treimer, W.; Strobl, M.; Feye-Treimer, U.; Beul, N.; Jericha, E.; Seidel, S. O.

    2010-11-01

    In the case of ultra small angle (neutron or x-ray) scattering (USANS, USAXS) it may happen that structures under investigations are not fully coherently illuminated by the incident wave. Despite this fact interference effects are observed similar to SAS data. In this case the measured scattering patterns must be different interpreted. We propose a procedure to calculate and adapt such scattering patterns to experimental data.

  4. Ultra small angle scattering versus diffraction

    International Nuclear Information System (INIS)

    Ebrahimi, O; Treimer, W; Strobl, M; Feye-Treimer, U; Beul, N; Jericha, E; Seidel, S O

    2010-01-01

    In the case of ultra small angle (neutron or x-ray) scattering (USANS, USAXS) it may happen that structures under investigations are not fully coherently illuminated by the incident wave. Despite this fact interference effects are observed similar to SAS data. In this case the measured scattering patterns must be different interpreted. We propose a procedure to calculate and adapt such scattering patterns to experimental data.

  5. Calibration of photographic dosemeters to evaluate the personal equivalent dose, Hp (10), irradiated by different radiation qualities and angles of incidence; Calibracao de dosimetros fotograficos para avaliar o equivalente de dose pessoal, Hp(10), irradiados por diferentes qualidades de radiacao e angulos de incidencia

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, Christiana; Antonio Filho, Joao, E-mail: chsantoro@gmail.com, E-mail: jaf@ufpe.br [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Santos, Marcus Aurelio P.; Goncalves Filho, Luiz Carlos, E-mail: masantos@cnen.gov.br, E-mail: l.filho@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, Pe (Brazil)

    2013-07-01

    To use radiation detectors, should periodically perform tests and calibrations on instruments in order to verify its good functionality. One way to ascertain the quality of the instrument is to conduct a study of the angular dependence of the response of the radiation detectors. The photographic dosimetry has been used widely to quantify the radiation doses and to estimate levels of doses received by workers involved with X-and gamma radiation. Photographic dosimeters are used because provide wide range of exposure and good accuracy. One of the sources of error have been introduced by different irradiation geometries between calibration and measurement in radiation fields used in x-ray and gamma ray sources, therefore, there is a need for an evaluation of the sensitivity of dosimeters with variation of the angle of the incident beam. In this study were tested 190 photographic dosemeters in the Metrology Laboratory of the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) using the phantom H{sub p} (10), where the dosimeters are evaluated on the basis of the new operational magnitude for individual monitoring, the equivalent personal dose, H{sub p} (10). Angular dependence of these radiation detectors was studied in X radiation fields (in the range of 45 keV energy to 164 keV) and gamma radiation ({sup 137}Cs-662 keV e {sup 60}Co - 1250 keV)

  6. Tibial and fibular angles in homozygous sickle cell disease

    International Nuclear Information System (INIS)

    Akamaguna, A.I.; Odita, J.C.; Ugbodaga, C.I.; Okafor, L.A.

    1986-01-01

    Measurements of the tibial and fibular angles made on ankle radiographs of 34 patients with sickle cell disease were compared with those of 36 normal Nigerians. Widening of the fibular angle, which is an indication of tibiotalar slant, was demonstrated in about 79% of sickle cell disease patients. By using fibular angle measurements as an objective method of assessing subtle tibiotalar slant, it is concluded that the incidence of this deformity is much higher among sickle cell disease patients than previously reported. The mean values of tibial and fibular angles in normal Nigerians are higher than has been reported amongst Caucasians. (orig.)

  7. Modified skin incision for avoiding the lesser occipital nerve and occipital artery during retrosigmoid craniotomy: potential applications for enhancing operative working distance and angles while minimizing the risk of postoperative neuralgias and intraoperative hemorrhage.

    Science.gov (United States)

    Tubbs, R Shane; Fries, Fabian N; Kulwin, Charles; Mortazavi, Martin M; Loukas, Marios; Cohen-Gadol, Aaron A

    2016-10-01

    Chronic postoperative neuralgias and headache following retrosigmoid craniotomy can be uncomfortable for the patient. We aimed to better elucidate the regional nerve anatomy in an effort to minimize this postoperative complication. Ten adult cadaveric heads (20 sides) were dissected to observe the relationship between the lesser occipital nerve and a traditional linear versus modified U incision during retrosigmoid craniotomy. Additionally, the relationship between these incisions and the occipital artery were observed. The lesser occipital nerve was found to have two types of course. Type I nerves (60%) remained close to the posterior border of the sternocleidomastoid muscle and some crossed anteriorly over the sternocleidomastoid muscle near the mastoid process. Type II nerves (40%) left the posterior border of the sternocleidomastoid muscle and swung medially (up to 4.5cm posterior to the posterior border of the sternocleidomastoid muscle) as they ascended over the occiput. The lesser occipital nerve was near a midpoint of a line between the external occipital protuberance and mastoid process in all specimens with the type II nerve configuration. Based on our findings, the inverted U incision would be less likely to injure the type II nerves but would necessarily cross over type I nerves, especially more cranially on the nerve at the apex of the incision. As the more traditional linear incision would most likely transect the type I nerves and more so near their trunk, the U incision may be the overall better choice in avoiding neural and occipital artery injury during retrosigmoid approaches. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. open angle glaucoma (poag)?

    African Journals Online (AJOL)

    there is a build up of pressure due to poor outflow of aqueous humor. The outflow obstruction could occur at the trabecular meshwork of the anterior chamber angle or subsequently in the episcleral vein due to raised venous pressure. Such build up of pressure results in glaucoma . Elevated intraocular pressure remains the ...

  9. The quadriceps angle

    DEFF Research Database (Denmark)

    Miles, James Edward; Frederiksen, Jane V.; Jensen, Bente Rona

    2012-01-01

    : Pelvic limbs from red foxes (Vulpes vulpes). METHODS: Q angles were measured on hip dysplasia (HD) and whole limb (WL) view radiographs of each limb between the acetabular rim, mid-point (Q1: patellar center, Q2: femoral trochlea), and tibial tuberosity. Errors of 0.5-2.0 mm at measurement landmarks...

  10. At Right Angles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 9. At Right Angles. Shailesh A Shirali. Information and Announcements Volume 17 Issue 9 September 2012 pp 920-920. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/017/09/0920-0920 ...

  11. The lateral angle revisited

    DEFF Research Database (Denmark)

    Morgan, Jeannie; Lynnerup, Niels; Hoppa, R.D.

    2013-01-01

    This article presents the results of a validation study of a previously published method of sex determination from the temporal bone. The purpose of this study was to evaluate the lateral angle method for the internal acoustic canal for accurately determining the sex of human skeletal remains usi...... method appears to be of minimal practical use in forensic anthropology and archeology....

  12. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Gupta, Sanjay

    1982-01-01

    The technique of small angle neutron scattering was first used in Germany less than two decades ago. Since then it has developed very rapidly, and today it is regarded as one of the most powerful techniques in materials, chemical and biological research. During the last decade the combination of high flux reactors and sophisticated instrumentation has revolutionized the technique. This paper endeavours to present a brief but comprehensive review of small angle scattering of neutrons and its applications in solid state research. The domain in which small angle neutron scattering is particularly useful is delineated and some of the methods used in the analysis of data are discussed with special emphasis on recent developments. Typical small angle neutron scattering cameras are described. Finally some experimental results on heterogeneities in metallic systems (both static and dynamic studies), radiation damage in materials, superconductivity, magnetic materials and the technologically very important area of non-destructive testing are reviewed in order to illustrate the wide range of applicability of this technique to problems in solid state research. (author)

  13. Neutron small angle scattering

    International Nuclear Information System (INIS)

    Ibel, K.

    1975-01-01

    The neutron small-angle scattering system at the High-Flux Reactor in Grenoble consists of three major parts: the supply of cold neutrons via bent neutron guides; the small angle camera D11; and the data handling facilities. The camera D11 has an overall length of 80 m. The effective length of the camera is variable. The length of the collimator before the fixed sample position can be reduced by movable neutron guides; the secondary flight path of 40 m full length contains detector sites in various positions. Thus, a large domain of momentum transfers can be exploited. Scattering angles between 5.10 -4 and 0.5 rad and neutron wavelengths from 0.2 to 2.0 nm are available with the same instrument and the same relative resolution. A large-area position-sensitive detector is used which allows simultaneous recording of intensities scattered into different angles; it is a multiwire proportional chamber. 3808 elements of 1 cm 2 are arranged in a two-dimensional matrix. Future development comprises an increase of the limit in the count rate due to the electronic interface between the detector and on-line computer, actually at 5.10 4 per sec. by one order of magnitude

  14. At Right Angles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 9. At Right Angles. Shailesh A Shirali. Information and Announcements Volume 17 Issue 9 September 2012 pp 920-920. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/017/09/0920-0920 ...

  15. Angle dependent Fiber Bragg grating inscription in microstructured polymer optical fibers

    DEFF Research Database (Denmark)

    Bundalo, Ivan-Lazar; Nielsen, Kristian; Bang, Ole

    2015-01-01

    We report on an incidence angle influence on inscription of the Fiber Bragg Gratings in Polymethyl methacrylate (PMMA) microstructured polymer optical fibers. We have shown experimentally that there is a strong preference of certain angles, labeled Gamma K, over the other ones. Angles close...

  16. Ultrathin triple-band polarization-insensitive wide-angle compact metamaterial absorber

    International Nuclear Information System (INIS)

    Shang, Shuai; Yang, Shizhong; Tao, Lu; Yang, Lisheng; Cao, Hailin

    2016-01-01

    In this study, the design, realization, and characterization of an ultrathin triple-band polarization-insensitive wide-angle metamaterial absorber are reported. The metamaterial absorber comprises a periodic array of modified six-fold symmetric snowflake-shaped resonators with strip spiral line load, which is printed on a dielectric substrate backed by a metal ground plane. It is shown that the absorber exhibits three distinct near-unity absorption peaks, which are distributed across C, X, Ku bands, respectively. Owing to the six-fold symmetry, the absorber is insensitive to the polarization of the incident radiation. In addition, the absorber shows excellent absorption performance over wide oblique incident angles for both transverse electric and transverse magnetic polarizations. Simulated surface current and field distributions at the three absorption peaks are demonstrated to understand the absorption mechanism. Particularly, the absorption modes come from the fundamental and high-order dipole resonances. Furthermore, the experimental verification of the designed absorber is conducted, and the measured results are in reasonable agreement with the simulated ones. The proposed ultrathin (∼0.018λ 0 , λ 0 corresponding to the lowest peak absorption frequency) compact (0.168λ 0 ×0.168λ 0 corresponding to the area of a unit cell) absorber enables potential applications such as stealth technology, electromagnetic interference and spectrum identification.

  17. Relationship between the angle of repose and angle of internal ...

    African Journals Online (AJOL)

    Abstract. Click on the link to view the abstract. Keywords: Angle of repose, angle of internal friction, granular materials, triaxial compression machine, moisture content. Tanzania J. Agric. Sc. (1998) Vol.1 No.2, 187-194 ...

  18. Ultra-small-angle neutron scattering with azimuthal asymmetry.

    Science.gov (United States)

    Gu, X; Mildner, D F R

    2016-06-01

    Small-angle neutron scattering (SANS) measurements from thin sections of rock samples such as shales demand as great a scattering vector range as possible because the pores cover a wide range of sizes. The limitation of the scattering vector range for pinhole SANS requires slit-smeared ultra-SANS (USANS) measurements that need to be converted to pinhole geometry. The desmearing algorithm is only successful for azimuthally symmetric data. Scattering from samples cut parallel to the plane of bedding is symmetric, exhibiting circular contours on a two-dimensional detector. Samples cut perpendicular to the bedding show elliptically dependent contours with the long axis corresponding to the normal to the bedding plane. A method is given for converting such asymmetric data collected on a double-crystal diffractometer for concatenation with the usual pinhole-geometry SANS data. The aspect ratio from the SANS data is used to modify the slit-smeared USANS data to produce quasi-symmetric contours. Rotation of the sample about the incident beam may result in symmetric data but cannot extract the same information as obtained from pinhole geometry.

  19. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-04-19

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Modified cyanobacteria

    Science.gov (United States)

    Vermaas, Willem F J.

    2014-06-17

    Disclosed is a modified photoautotrophic bacterium comprising genes of interest that are modified in terms of their expression and/or coding region sequence, wherein modification of the genes of interest increases production of a desired product in the bacterium relative to the amount of the desired product production in a photoautotrophic bacterium that is not modified with respect to the genes of interest.

  1. Critical angle laser refractometer

    International Nuclear Information System (INIS)

    Castrejon-Pita, J.R.; Morales, A.; Castrejon-Garcia, R.

    2006-01-01

    A simple laser refractometer based on the detection of the critical angle for liquids is presented. The calibrated refractometer presents up to 0.000 11 of uncertainty when the refractive index is in the range between 1.300 00 and 1.340 00. The experimental setup is easy to construct and the material needed is available at most optics laboratories. The calibration method is simple and can be used in other devices. The refractive index measurements in aqueous solutions of sodium chloride were carried out to test the device and a linear dependence between the refractive index and the salt concentration was found

  2. Control of Angular Intervals for Angle-Multiplexed Holographic Memory

    Science.gov (United States)

    Kinoshita, Nobuhiro; Muroi, Tetsuhiko; Ishii, Norihiko; Kamijo, Koji; Shimidzu, Naoki

    2009-03-01

    In angle-multiplexed holographic memory, the full width at half maximum of the Bragg selectivity curves is dependent on the angle formed between the medium and incident laser beams. This indicates the possibility of high density and high multiplexing number by varying the angular intervals between adjacent holograms. We propose an angular interval scheduling for closely stacking holograms into medium even when the angle range is limited. We obtained bit error rates of the order of 10-4 under the following conditions: medium thickness of 1 mm, laser beam wavelength of 532 nm, and angular multiplexing number of 300.

  3. Scaling of misorientation angle distributions

    DEFF Research Database (Denmark)

    Hughes, D.A.; Chrzan, D.C.; Liu, Q.

    1998-01-01

    The measurement of misorientation angle distributions following different amounts of deformation in cold-rolled aluminum and nickel and compressed stainless steel is reported. The sealing of the dislocation cell boundary misorientation angle distributions is studied. Surprisingly, the distributio...

  4. Angle performance on optima MDxt

    Energy Technology Data Exchange (ETDEWEB)

    David, Jonathan; Kamenitsa, Dennis [Axcelis Technologies, Inc., 108 Cherry Hill Dr, Beverly, MA 01915 (United States)

    2012-11-06

    Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).

  5. Variable angle correlation spectroscopy

    International Nuclear Information System (INIS)

    Lee, Y.K.; Lawrence Berkeley Lab., CA

    1994-05-01

    In this dissertation, a novel nuclear magnetic resonance (NMR) technique, variable angle correlation spectroscopy (VACSY) is described and demonstrated with 13 C nuclei in rapidly rotating samples. These experiments focus on one of the basic problems in solid state NMR: how to extract the wealth of information contained in the anisotropic component of the NMR signal while still maintaining spectral resolution. Analysis of the anisotropic spectral patterns from poly-crystalline systems reveal information concerning molecular structure and dynamics, yet in all but the simplest of systems, the overlap of spectral patterns from chemically distinct sites renders the spectral analysis difficult if not impossible. One solution to this problem is to perform multi-dimensional experiments where the high-resolution, isotropic spectrum in one dimension is correlated with the anisotropic spectral patterns in the other dimensions. The VACSY technique incorporates the angle between the spinner axis and the static magnetic field as an experimental parameter that may be incremented during the course of the experiment to help correlate the isotropic and anisotropic components of the spectrum. The two-dimensional version of the VACSY experiments is used to extract the chemical shift anisotropy tensor values from multi-site organic molecules, study molecular dynamics in the intermediate time regime, and to examine the ordering properties of partially oriented samples. The VACSY technique is then extended to three-dimensional experiments to study slow molecular reorientations in a multi-site polymer system

  6. Variable angle correlation spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Kyo [Univ. of California, Berkeley, CA (United States)

    1994-05-01

    In this dissertation, a novel nuclear magnetic resonance (NMR) technique, variable angle correlation spectroscopy (VACSY) is described and demonstrated with 13C nuclei in rapidly rotating samples. These experiments focus on one of the basic problems in solid state NMR: how to extract the wealth of information contained in the anisotropic component of the NMR signal while still maintaining spectral resolution. Analysis of the anisotropic spectral patterns from poly-crystalline systems reveal information concerning molecular structure and dynamics, yet in all but the simplest of systems, the overlap of spectral patterns from chemically distinct sites renders the spectral analysis difficult if not impossible. One solution to this problem is to perform multi-dimensional experiments where the high-resolution, isotropic spectrum in one dimension is correlated with the anisotropic spectral patterns in the other dimensions. The VACSY technique incorporates the angle between the spinner axis and the static magnetic field as an experimental parameter that may be incremented during the course of the experiment to help correlate the isotropic and anisotropic components of the spectrum. The two-dimensional version of the VACSY experiments is used to extract the chemical shift anisotropy tensor values from multi-site organic molecules, study molecular dynamics in the intermediate time regime, and to examine the ordering properties of partially oriented samples. The VACSY technique is then extended to three-dimensional experiments to study slow molecular reorientations in a multi-site polymer system.

  7. Small angle neutron scattering

    International Nuclear Information System (INIS)

    Dasannacharya, B.A.; Goyal, P.S.

    1997-01-01

    Small angle neutron scattering (SANS) is one of the most popular neutron scattering technique both for the basic research and as a tool in the hands of applied scientist. SANS is used for studying the structure of a material on a length scale of 10 - 1000 A. SANS is a diffraction experiment that involves scattering of a monocromatic beam of neutrons in order to obtain structural information about macromolecules and heterogeneities. This paper will discuss the design of SANS spectrometers with a special emphasis on the instruments which are better suited for medium flux reactors. The design of several different types of SANS spectrometers will be given. The optimization procedures and appropriate modifications to suit the budget and the space will be discussed. As an example, the design of a SANS spectrometer at CIRUS reactor Trombay will be given. (author)

  8. Grazing incidence polarized neutron scattering in reflection ...

    Indian Academy of Sciences (India)

    During the year 1980, polarized neutron scattering technique came into being as an ana- lytic tool to measure the ... The discovery of antiferromagnetic coupling was critical to the discovery of GMR, pro- viding as it did ..... Here we consider the incident wave vector ki making an angle αi in the x–z plane while the scattered ...

  9. Grazing Incidence X-ray Scattering and Diffraction

    Indian Academy of Sciences (India)

    IAS Admin

    tion. In thia article, various aspects of surface X- ray diffraction and scattering are discussed with illustrations of some typical applications of these techniques. 1. ..... ray reflectivity. Here, X-rays are incident on the sample at very small grazing angles to the surface and below the critical angle, αc. As explained earlier, this ...

  10. Generalization of the Euler Angles

    Science.gov (United States)

    Bauer, Frank H. (Technical Monitor); Shuster, Malcolm D.; Markley, F. Landis

    2002-01-01

    It is shown that the Euler angles can be generalized to axes other than members of an orthonormal triad. As first shown by Davenport, the three generalized Euler axes, hereafter: Davenport axes, must still satisfy the constraint that the first two and the last two axes be mutually perpendicular if these axes are to define a universal set of attitude parameters. Expressions are given which relate the generalized Euler angles, hereafter: Davenport angles, to the 3-1-3 Euler angles of an associated direction-cosine matrix. The computation of the Davenport angles from the attitude matrix and their kinematic equation are presented. The present work offers a more direct development of the Davenport angles than Davenport's original publication and offers additional results.

  11. Carbon sputtering yield measurements at grazing incidence

    International Nuclear Information System (INIS)

    Kolasinski, Robert D.; Polk, James E.; Goebel, Dan; Johnson, Lee K.

    2008-01-01

    In this investigation, carbon sputtering yields were measured experimentally at varying angles of incidence under Xe + bombardment. The measurements were obtained by etching a coated quartz crystal microbalance (QCM) with a low energy ion beam. The material properties of the carbon targets were characterized with a scanning electron microscope (SEM) and Raman spectroscopy. C sputtering yields measured under Ar + and Xe + bombardment at normal incidence displayed satisfactory agreement with previously published data over an energy range of 200 eV-1 keV. For Xe + ions, the dependence of the yields on angle of incidence θ was determined for 0 o ≤ θ ≤ 80 deg. Over this range, an increase in C sputtering yield by a factor of 4.8 was observed, with the peak in yield occurring at 70 o . This is a much higher variation compared to Xe + → Mo yields under similar conditions, a difference that may be attributed to higher scattering of the incident particles transverse to the beam direction than in the case of Xe + → C. In addition, the variation of the yields with θ was not strongly energy dependent. Trapping of Xe in the surface was observed, in contrast to observations using the QCM technique with metallic target materials. Finally, target surface roughness was characterized using atomic force microscope measurements to distinguish between the effects of local and overall angle of incidence of the target

  12. Modifiable risk factors of obstetric anal sphincter injury in primiparous women

    DEFF Research Database (Denmark)

    Jango, Hanna; Langhoff-Roos, Jens; Rosthøj, Susanne

    2014-01-01

    To determine modifiable risk factors and incidence of obstetric anal sphincter injury (OASIS) in primiparous women.......To determine modifiable risk factors and incidence of obstetric anal sphincter injury (OASIS) in primiparous women....

  13. Angle Performance on Optima XE

    International Nuclear Information System (INIS)

    David, Jonathan; Satoh, Shu

    2011-01-01

    Angle control on high energy implanters is important due to shrinking device dimensions, and sensitivity to channeling at high beam energies. On Optima XE, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through a series of narrow slits, and any angle adjustment is made by steering the beam with the corrector magnet. In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen during implant.Using a sensitive channeling condition, we were able to quantify the angle repeatability of Optima XE. By quantifying the sheet resistance sensitivity to both horizontal and vertical angle variation, the total angle variation was calculated as 0.04 deg. (1σ). Implants were run over a five week period, with all of the wafers selected from a single boule, in order to control for any crystal cut variation.

  14. Relationship between the Angle of Repose and Angle of Internal ...

    African Journals Online (AJOL)

    ghum and rice. The angles have a big influence on the design offlow and storage structures of ... the angles of internal friction for the same grains and same moisture contents. The data ob- tained were fed into SAS statistical software for step-wise regression analysis. A model of the ..... tion, Application and Validation of En-.

  15. Measurement of the angle gamma

    International Nuclear Information System (INIS)

    Aleksan, R.; Sphicas, P.; Massachusetts Inst. of Tech., Cambridge, MA

    1993-12-01

    The angle γ as defined in the Wolfenstein approximation is not completely out of reach of current or proposed dedicated B experiments. This work represents but a first step in the direction of extracting the third angle of the unitarity triangle by study the feasibility of using new decay modes in a hadronic machine. (A.B.). 11 refs., 1 fig., 7 tabs

  16. Nucleation of small angle boundaries

    CSIR Research Space (South Africa)

    Nabarro, FRN

    1996-12-01

    Full Text Available The internal stresses induced by the strain gradients in an array of lattice cells delineated by low-angle dislocation boundaries are partially relieved by the creation of new low-angle boundaries. This is shown to be a first-order transition...

  17. Simulation and Measurement of Angle Resolved Reflectance from Black Si Surfaces

    DEFF Research Database (Denmark)

    Davidsen, Rasmus Schmidt; Wu, Kaiyu; Schmidt, Michael Stenbæk

    2015-01-01

    In this work angle-resolved reflectance from nanostructured Si surfaces realized by maskless RIE texturing has been simulated and measured. The simulation and experimental measurement data show the same trend. Experimentally a total reflectance below 1% for incident angles below 30o and specular...

  18. Influence of oblique-angle sputtered transparent conducting oxides on performance of Si-based thin film solar cells

    International Nuclear Information System (INIS)

    Leem, Jung Woo; Yu, Jae Su

    2011-01-01

    The transparent conducting oxide (TCO) films with low-refractive-index (low-n) are fabricated by the oblique-angle sputtering method. By using the experimentally measured physical data of the fabricated low-n TCO films as the simulation parameters, the effect of low-n TCOs on the performance of a-Si:H/μc-Si:H tandem thin film solar cells is investigated using Silvaco ATLAS. The Al-doped zinc oxide, indium tin oxide (ITO), and Sb-doped tin oxide films are deposited at the flux incidence angles of θ i = 0 (normal sputtering) and θ i = 80 from the sputtering target during the sputtering process. The oblique-angle sputtered films at θ i = 80 show the inclined columnar nanostructures compared to those at θ i = 0 , modifying the optical properties of the films. This is caused mainly by the increase of porosity within the film which leads to its low-n characteristics. The a-Si:H/μc-Si:H tandem thin film solar cell incorporated with the low-n ITO film exhibits an improvement in the conversion efficiency of ∝1% under AM1.5g illumination because of its higher transmittance and lower absorption compared to that with the ITO film at θ i = 0 , indicating a conversion efficiency of 13.75%. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Influence of oblique-angle sputtered transparent conducting oxides on performance of Si-based thin film solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Leem, Jung Woo; Yu, Jae Su [Department of Electronics and Radio Engineering, Kyung Hee University, 1 Seocheon-dong, Giheung-gu, Yongin-si, Gyeonggi-do 446-701 (Korea, Republic of)

    2011-09-15

    The transparent conducting oxide (TCO) films with low-refractive-index (low-n) are fabricated by the oblique-angle sputtering method. By using the experimentally measured physical data of the fabricated low-n TCO films as the simulation parameters, the effect of low-n TCOs on the performance of a-Si:H/{mu}c-Si:H tandem thin film solar cells is investigated using Silvaco ATLAS. The Al-doped zinc oxide, indium tin oxide (ITO), and Sb-doped tin oxide films are deposited at the flux incidence angles of {theta}{sub i} = 0 (normal sputtering) and {theta}{sub i} = 80 from the sputtering target during the sputtering process. The oblique-angle sputtered films at {theta}{sub i} = 80 show the inclined columnar nanostructures compared to those at {theta}{sub i} = 0 , modifying the optical properties of the films. This is caused mainly by the increase of porosity within the film which leads to its low-n characteristics. The a-Si:H/{mu}c-Si:H tandem thin film solar cell incorporated with the low-n ITO film exhibits an improvement in the conversion efficiency of {proportional_to}1% under AM1.5g illumination because of its higher transmittance and lower absorption compared to that with the ITO film at {theta}{sub i} = 0 , indicating a conversion efficiency of 13.75%. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Jogging Can Modify Disruptive Behaviors.

    Science.gov (United States)

    Allen, Jill I.

    1980-01-01

    Jogging was used to modify disruptive behavior as part of the classroom routine for 12 learning disabled elementary-grade boys. The number of incidents of each of five negative behaviors were reduced by half following the 10-minute jogging routine. (SBH)

  1. A study on projection angles for an optimal image of PNS water's view on children

    International Nuclear Information System (INIS)

    Son, Sang Hyuk; Song, Young Geun; Kim, Sung Kyu; Hong, Sang Woo; Kim, Je Bong

    2007-01-01

    This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patient's skull. And then, we calculated the incidence angles (angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general (random) patient's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patient's ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle (angle B) between OML and IP(Image Plate). The angle between OML and IP is about 43 .deg. in 4-years-old children, which is higher than 37 .deg. as age increases the angle decreases, it goes to 37 .deg. around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage

  2. X-ray diffraction at Bragg angles around π/2

    International Nuclear Information System (INIS)

    Mayolo, C.M.G. de.

    1991-01-01

    X-ray diffraction at Bragg angles around π/2 is studied from the theoretical and experimental points of view. The proposed corrections to the dynamical theory in the θ β ≅ π/2 cases, has been reviewed showing the equivalence between two formalisms leading to a corrected expression for the dependence of the angular parameter y with the angle of incidence. An expression for y valid in the conventional and θ β ≅ π/2 cases has been obtained. A general expression for Bragg law and for energy resolution after a Bragg diffraction was also deduced. (author)

  3. Transmission-type angle deviation microscopy

    International Nuclear Information System (INIS)

    Chiu, M.-H.; Lai, C.-W.; Tan, C.-T.; Lai, C.-F.

    2008-01-01

    We present a new microscopy technique that we call transmission angle deviation microscopy (TADM). It is based on common-path heterodyne interferometry and geometrical optics. An ultrahigh sensitivity surface plasmon resonance (SPR) angular sensor is used to expand dynamic measurement ranges and to improve the axial resolution in three-dimensional optical microscopy. When transmitted light is incident upon a specimen, the beam converges or diverges because of refractive and/or surface height variations. Advantages include high axial resolution (∼32 nm), nondestructive and noncontact measurement, and larger measurement ranges (± 80 μm) for a numerical aperture of 0.21in a transparent measurement medium. The technique can be used without conductivity and pretreatment

  4. Angle resolved characterization of nanostructured and conventionally textured silicon solar cells

    DEFF Research Database (Denmark)

    Davidsen, Rasmus Schmidt; Ormstrup, Jeppe; Ommen, Martin Lind

    2015-01-01

    current, open circuit voltage, fill factor (FF) and power conversion efficiency are each measured as function of the relative incident angle between the solar cell and the light source. The relative incident angle is varied from 0° to 90° in steps of 10° in orthogonal axes, such that each solar cell......We report angle resolved characterization of nanostructured and conventionally textured silicon solar cells. The nanostructured solar cells are realized through a single step, mask-less, scalable reactive ion etching (RIE) texturing of the surface. Photovoltaic properties including short circuit...

  5. Numerical study of hub taper angle on podded propeller performance

    International Nuclear Information System (INIS)

    Islam, M.F.; Veitch, B.; Bose, N.; Liu, P.

    2005-01-01

    Presently, the majority of podded propulsion systems are of the pulling type, because this type provides better hydrodynamic efficiency than the pushing type. There are several possible explanations for the better overall performance of a puller type podded propulsor. One is related to the difference in hub shape. Puller and pusher propellers have opposite hub taper angles, hence different hub and blade root shape. These differences cause changes in the flow condition and possibly influence the overall performance. The current study focuses on the variation in performance of pusher and puller propellers with the same blade sections, but different hub taper angles. A hyperboloidal low order source doublet steady/unsteady time domain panel method code was modified and used to evaluate effects of hub taper angle on the open water propulsive performance of some fixed pitch screw propellers used in podded propulsion systems. The modified code was first validated against measurements of two model propellers in terms of average propulsive performance and good agreement was found. Major findings include significant effects of hub taper angle on propulsive performance of tapered hub propellers and noticeable effects of hub taper angle on sectional pressure distributions of tapered hub propeller blades. (author)

  6. Dissociative Tendencies and Traffic Incidents

    Directory of Open Access Journals (Sweden)

    Valle, Virginia

    2012-01-01

    Full Text Available This paper analyses the relationship between dissociative experiences and road traffic incidents (crashes and traffic tickets in drivers (n=295 from Mar del Plata (Argentina city. A self-report questionnaire was applied to assess traffic crash involvement and sociodemographic variables. Dissociative tendencies were assessed by a modified version of the DES scale. To examine differences in DES scores tests of the difference of means were applied. Drivers who reported to be previously involved in traffic incidents obtained higher puntuations in the dissociative experiences scale than drivers who did not report such events. This result is observed for the total scale and for the three sub-scales (absorption, amnesia and depersonalization. However, differences appeared mainly for minor damage collisions. Further studies are needed to evaluate the role of dissociative tendencies as a risk factor in road traffic safety.

  7. Evaluation of the anterior chamber angle in pseudoexfoliation syndrome.

    Science.gov (United States)

    Iwanejko, Małgorzata; Turno-Kręcicka, Anna; Tomczyk-Socha, Martyna; Kaczorowski, Kamil; Grzybowski, Andrzej; Misiuk-Hojło, Marta

    2017-08-01

    Pseudoexfoliation syndrome (PEX) is the most frequently identifiable cause of secondary open-angle glaucoma, known as pseudoexfoliation glaucoma. The exact pathophysiology and etiology of PEX and associated glaucoma remains obscure. The purpose of this study was to determine the differences in the morphology of the anterior chamber angle in people with pseudoexfoliation syndrome and pseudoexfoliation glaucoma compared to a control group. We also evaluated the correlation between intraocular pressure (IOP) and pigmentation of the angle with the amount of exfoliated material in the anterior segment. The study group was composed of 155 eyes from 103 patients aged between 43 and 86 years. Each patient underwent a complete ophthalmological examination. Some difference was found in intraocular pressure between the PEX group and the control group and between the pseudoexfoliation glaucoma group and the control group, but no significant difference was found between the 2 study groups. There was a significant difference in the incidence of some degree of pigmentation in the anterior chamber angle and no difference in the widths of the angle between each group. A significant positive relationship was observed between intraocular pressure and the degree of pigmentation of the anterior chamber angle in both the PEX group and the pseudoexfoliation glaucoma group. The results of this study indicate that the amount of pigmentation and exfoliation material in the anterior segment significantly correlates with the level of IOP and possibly with the degree of trabecular dysfunction. It seems that for clear identification of PEX and pseudoexfoliation glaucoma factors, clinical assessment appears to be insufficient.

  8. Vacuum variable-angle far-infrared ellipsometer

    Science.gov (United States)

    Friš, Pavel; Dubroka, Adam

    2017-11-01

    We present the design and performance of a vacuum far-infrared (∼50-680 cm-1) ellipsometer with a rotating analyser. The system is based on a Fourier transform spectrometer, an in-house built ellipsometer chamber and a closed-cycle bolometer. The ellipsometer chamber is equipped with a computer controlled θ-2θ goniometer for automated measurements at various angles of incidence. We compare our measurements on SrTiO3 crystal with the results acquired above 300 cm-1 with a commercially available ellipsometer system. After the calibration of the angle of incidence and after taking into account the finite reflectivity of mirrors in the detector part we obtain a very good agreement between the data from the two instruments. The system can be supplemented with a closed-cycle He cryostat for measurements between 5 and 400 K.

  9. Hadron elastic scattering at small angles

    CERN Multimedia

    2002-01-01

    This experiment is an extension of the measurements of the WA9 experiment up to the highest energies available in the North Area. It will measure the differential cross-section for hadron elastic scattering in the t-range 0.002-0.05 (GeV/c)$^{2}$ using an ionization chamber for the measurement of the energy and the angle of the recoil and a magnet-WC spectrometer to measure the momentum and direction of the forward particle. From these measurements will be obtained the ratio $\\rho$ of the real to imaginary parts of the forward elastic amplitude and the exponential slope parameter b of the hadronic amplitude at small t. The precision expected in these measurements is $\\Delta \\rho \\approx \\pm 0.01$ and $\\Delta$b $\\approx \\pm 0.2$ (GeV/c)$^{-2}$. \\\\ \\\\ The experimental programme includes: \\\\\\\\ i) measurements of $\\rho$ and b for $\\pi$p elastic scattering at incident momenta between 150 GeV/c and 300 GeV/c; \\\\ ii) measurements of $\\rho$ and b for $\\pi^{+}$p and pp elastic scattering at incident momenta between 5...

  10. Note: Optimization of magnifying a polarization angle with Littrow layout blazed gratings.

    Science.gov (United States)

    Sasao, H; Arakawa, H; Imazawa, R; Kawano, Y; Itami, K; Kubo, H

    2017-03-01

    Magnification of a polarization angle with Littrow layout gratings has been developed. High magnification with a factor of 7.7 using two gratings in Littrow layout was experimentally proved. The magnification range was investigated by calculation at a wavelength of 10.6 μm. The method can be applied for a high magnification factor >30. Larger groove numbers and smaller blaze angles are suitable for the large magnification. Statistical fluctuation of the diffracted polarization angle is compared with that of the incident polarization angle.

  11. Angle-of-attack estimation for analysis of CAT encounters

    Science.gov (United States)

    Bach, R. E., Jr.; Parks, E. K.

    1985-01-01

    Recent studies of clear-air turbulence (CAT) encounters involving wide-body airliners have been based upon flight-path wind estimates made by analyzing digital flight-data-recorder (DFDR) records and radar records. Such estimates require a time history of the aircraft angle of attack, a record that is not usually included in the DFDR measurement set. This paper describes a method for reconstructing angle of attack that utilizes available flight record and aircraft-specific information associated with an aerodynamic model of the lift coefficient. Results from two wide-body incidents in which vane measurements of angle of attack were recorded show good agreement between measured and calculated time histories. This research has been performed in cooperation with the National Transportation Safety Board to provide a better understanding of the CAT phenomenon.

  12. Effects of slant angle and illumination angle on MTF estimations

    CSIR Research Space (South Africa)

    Vhengani, LM

    2012-07-01

    Full Text Available angle d(?) was not constant. It was also noted that the iris of the imaging system was in most cases adjusted during initial setups of each measurements. After each measurement, the knife-edge target was replaced with the ISO 12233 MTF target (shown....085 0.09 0.095 K:\\Working Folder\\Project_On_orbit MTF\\edgetargets\\MTF_Lab_Measurements _20120302_Edge Slant Angle (degrees) Ny qu ist MT F (c yc le/p ixe l) Data Regression -18 -16 -14 -12 -10 -8 -6 -4 -2 0.05 0.055 0.06 0...

  13. MCFRS Incidents by Station

    Data.gov (United States)

    Montgomery County of Maryland — This dataset contains the monthly summary data indicating incident occurred in each fire station response area. The summary data is the incident count broken down by...

  14. Police Incident Reports Written

    Data.gov (United States)

    Town of Chapel Hill, North Carolina — This table contains incident reports filed with the Chapel Hill Police Department. Multiple incidents may have been reported at the same time. The most serious...

  15. Incident Information Management Tool

    CERN Document Server

    Pejovic, Vladimir

    2015-01-01

    Flaws of\tcurrent incident information management at CMS and CERN\tare discussed. A new data\tmodel for future incident database is\tproposed and briefly described. Recently developed draft version of GIS-­‐based tool for incident tracking is presented.

  16. Frequency scaling for angle gathers

    KAUST Repository

    Zuberi, M. A H

    2014-01-01

    Angle gathers provide an extra dimension to analyze the velocity after migration. Space-shift and time shift-imaging conditions are two methods used to obtain angle gathers, but both are reasonably expensive. By scaling the time-lag axis of the time-shifted images, the computational cost of the time shift imaging condition can be considerably reduced. In imaging and more so Full waveform inversion, frequencydomain Helmholtz solvers are used more often to solve for the wavefields than conventional time domain extrapolators. In such cases, we do not need to extend the image, instead we scale the frequency axis of the frequency domain image to obtain the angle gathers more efficiently. Application on synthetic data demonstrate such features.

  17. Temperature dependence of Brewster's angle.

    Science.gov (United States)

    Guo, Wei

    2018-01-01

    In this work, a dielectric at a finite temperature is modeled as an ensemble of identical atoms moving randomly around where they are trapped. Light reflection from the dielectric is then discussed in terms of atomic radiation. Specific calculation demonstrates that because of the atoms' thermal motion, Brewster's angle is, in principle, temperature-dependent, and the dependence is weak in the low-temperature limit. What is also found is that the Brewster's angle is nothing but a result of destructive superposition of electromagnetic radiation from the atoms.

  18. Angle independent velocity spectrum determination

    DEFF Research Database (Denmark)

    2014-01-01

    An ultrasound imaging system (100) includes a transducer array (102) that emits an ultrasound beam and produces at least one transverse pulse-echo field that oscillates in a direction transverse to the emitted ultrasound beam and that receive echoes produced in response thereto and a spectral vel...... velocity estimator (110) that determines a velocity spectrum for flowing structure, which flows at an angle of 90 degrees and flows at angles less than 90 degrees with respect to the emitted ultrasound beam, based on the received echoes....

  19. Kinematics of reflections in subsurface offset and angle-domain image gathers

    Science.gov (United States)

    Dafni, Raanan; Symes, William W.

    2018-02-01

    Seismic migration in the angle-domain generates multiple images of the earth's interior, in which reflection takes place at different scattering-angles. Mechanically, the angle-dependent reflection is restricted to happen instantaneously and at a fixed point in space: Incident wave hits a discontinuity in the subsurface media and instantly generates a scattered wave at the same common point of interaction. Alternatively, the angle-domain image may be associated with space-shift (regarded as subsurface offset) extended migration that artificially splits the reflection geometry. Meaning that, incident and scattered waves interact at some offset distance. The geometric differences between the two approaches amount to a contradictory angle-domain behavior, and unlike kinematic description. We present a phase space depiction of migration methods extended by the peculiar subsurface offset split, and stress its profound dissimilarity. In spite of being in radical contradiction with the general physics, the subsurface offset reveals a link to some valuable angle-domain quantities, via post-migration transformations. The angle quantities are indicated by the direction normal to the subsurface offset extended image. They specifically define the local dip and scattering angles if the velocity at the split reflection coordinates is the same for incident and scattered wave-pairs. Otherwise, the reflector normal is not a bisector of the opening angle, but of the corresponding slowness vectors. This evidence, together with the distinguished geometry configuration, fundamentally differentiates the angle-domain decomposition based on the subsurface offset split from the conventional decomposition at a common reflection point. An asymptotic simulation of angle-domain moveout curves in layered media exposes the notion of split versus common reflection point geometry. Traveltime inversion methods that involve the subsurface offset extended migration must accommodate the split geometry

  20. Kinematics of reflections in subsurface offset and angle-domain image gathers

    Science.gov (United States)

    Dafni, Raanan; Symes, William W.

    2018-05-01

    Seismic migration in the angle-domain generates multiple images of the earth's interior in which reflection takes place at different scattering-angles. Mechanically, the angle-dependent reflection is restricted to happen instantaneously and at a fixed point in space: Incident wave hits a discontinuity in the subsurface media and instantly generates a scattered wave at the same common point of interaction. Alternatively, the angle-domain image may be associated with space-shift (regarded as subsurface offset) extended migration that artificially splits the reflection geometry. Meaning that, incident and scattered waves interact at some offset distance. The geometric differences between the two approaches amount to a contradictory angle-domain behaviour, and unlike kinematic description. We present a phase space depiction of migration methods extended by the peculiar subsurface offset split and stress its profound dissimilarity. In spite of being in radical contradiction with the general physics, the subsurface offset reveals a link to some valuable angle-domain quantities, via post-migration transformations. The angle quantities are indicated by the direction normal to the subsurface offset extended image. They specifically define the local dip and scattering angles if the velocity at the split reflection coordinates is the same for incident and scattered wave pairs. Otherwise, the reflector normal is not a bisector of the opening angle, but of the corresponding slowness vectors. This evidence, together with the distinguished geometry configuration, fundamentally differentiates the angle-domain decomposition based on the subsurface offset split from the conventional decomposition at a common reflection point. An asymptotic simulation of angle-domain moveout curves in layered media exposes the notion of split versus common reflection point geometry. Traveltime inversion methods that involve the subsurface offset extended migration must accommodate the split geometry

  1. Standing phase angle reduction for power system restoration

    Energy Technology Data Exchange (ETDEWEB)

    Hazarika, D. [Assam Engineering College (India). Electrical Engineering Dept.; Sinha, A.K. [IIT Khargpur (India). Electrical Engineering Dept.

    1998-01-01

    The paper describes a methodology for the reduction of standing phase angle (SPA) difference between two buses of a power system, which is essential before interconnecting a line between two buses. This problem is encountered normally during restoration operations of a power system. For this purpose, the standing phase angle difference between two specific buses is represented in terms of sensitivity factors associated with the change in real power injections at the buses. To arrive at the desired standing phase angle difference between two buses, the modified contribution at generation/load buses have been evaluated based on 'higher the sensitivity higher the participation' logic. This methodology acts as a direct help to reduce excessive SPA difference between two buses to an acceptable limit, which otherwise requires regulation of various generation levels on a trial and error basis. (author)

  2. Philosophical Research on Genetically Modified Food

    OpenAIRE

    Meng Zhang

    2015-01-01

    This study mainly analyzes the essential features of transgenic technology from the angle of philosophy, explaining the essential characteristics of transgenic technology, so as to promote the better development of genetically modified food. With the technical improvement, genetically modified food is no longer strange, which has been applied in the production of our life. Compared with the traditional biological breeding, transgenic food has changed significantly in nature. Trying to meet th...

  3. Interfacial Modifiers

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Ina; French, Roger H.

    2018-03-19

    Our project objective in the first and only Budget Period was to demonstrate the potential of nm-scale organofunctional silane coatings as a method of extending the lifetime of PV materials and devices. Specifically, the target was to double the lifetime performance of a laminated Cu(In,Ga)Se2 (CIGS) cell under real-world and accelerated aging exposure conditions. Key findings are that modification of aluminum-doped zinc oxide (AZO) films (materials used as transparent conductive oxide (TCO) top contacts) resulted in decreased degradation of optical and electrical properties under damp heat (DH) exposure compared to un-modified AZO. The most significant finding is that modification of the AZO top contact of full CIGS devices resulted in significantly improved properties under DH exposure compared to un-modified devices, by a factor of 4 after 1000 h. Results of this one-year project have demonstrated that surface functionalization is a viable pathway for extending the lifetime of state-of-the-art CIGS devices.

  4. A Hitch Angle Measurement Device

    National Research Council Canada - National Science Library

    Von

    1998-01-01

    As part of a project to demonstrate that an unmanned ground vehicle (UGV) could remotely back up with a trailer, a simple proof-of-concept device was designed to measure the angle between a high-mobility multipurpose wheeled vehicle (HMMWV...

  5. Small-angle neutron-scattering experiment, (2)

    International Nuclear Information System (INIS)

    Niimura, Nobuo; Kaji, Harumi.

    1983-01-01

    Elementary explanation is given to the experiment on the small angle scattering using neutrons having long wave-length (3-12A), continued from the previous report. Two types of the apparatus for small angle neutron scattering experiment are described. The first is angle dispersion type, which uses the neutron beam from research reactors, and the second is wavelength dispersion type, which uses pulsed cold neutron sources. The principles of these experiments are explained. Especially the wavelength dispersion is described in detail. The apparatus in the booster facility at the Institute for High Energy Physics is shown as an example for the latter type. The two-dimensional position sensitive detector, which is essential for angle dispersion type, is also used for the wavelength dispersion type, and its data processing is also described. In the small angle neutron scattering experiment for the studies on the structure of living body substances, the techniques that should be taken into account in common are discussed; the proportion of D 2 O-H 2 O in solvent, the measurable range of Q, the size of specimens, the correction of incident neutron spectra, and the analysis of measured data. (Asami, T.)

  6. Measurement of the Euler Angles of Wurtzitic ZnO by Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Wu Liu

    2017-01-01

    Full Text Available A Raman spectroscopy-based step-by-step measuring method of Euler angles φ,θ,and  ψ was presented for the wurtzitic crystal orientation on a microscopic scale. Based on the polarization selection rule and coordinate transformation theory, a series of analytic expressions for the Euler angle measurement using Raman spectroscopy were derived. Specific experimental measurement processes were presented, and the measurement of Raman tensor elements and Euler angles of the ZnO crystal were implemented. It is deduced that there is a trigonometric functional relationship between the intensity of each Raman bands of wurtzite crystal and Euler angle ψ, the polarization direction of incident light under different polarization configurations, which can be used to measure the Euler angles. The experimental results show that the proposed method can realize the measurement of Euler angles for wurtzite crystal effectively.

  7. [Research on the transmittance spectrum of wedge thin film filter with oblique incidence].

    Science.gov (United States)

    Yu, Kan; Huang, De-Xiu; Yin, Juan-Juan; Bao, Jia-Qi

    2013-08-01

    Angle-tuned thin film filter is widely used in the DWDM system for its broad tunable wavelength range and high rectangular degree. The transmissivity and the half bandwidth is greatly influenced not only by the incident angle, but also by the wedge angle of the non-paralleled thin film filter. In the present paper, the influences of the wedge angle on the transmissivity and the half bandwidth were detailedly analyzed. The proper wedge angle and the orientation can greatly improve the characteristics of the transmittance spectrum. The angle-tuned thin film filter with 0.8 degrees wedge angle was also fabricated. The experimental results show that keeping the wedge angle with the same orientation to the incident angle will worsen the transmissivity and the rectangular degree of the transmittance spectrum. However, keeping the wedge angle orientation reverse to the incident angle will greatly enhance the transmissivity and the rectangular degree of the filter and its tunable wavelength range will broaden by 10 nm.

  8. Modifiable lifestyle factors and ovarian cancer incidence in women

    Directory of Open Access Journals (Sweden)

    Katarzyna Plagens-Rotman

    2018-03-01

    A diet rich in fruit and vegetables, including bulb vegetables, and grain products containing whole grains, should be introduced. It is recommended that the consumption of popular fast foods be eliminated.

  9. System for the Automatic Estimation of the Tilt Angle of a Flat Solar Collector

    Directory of Open Access Journals (Sweden)

    Jorge Fonseca-Campos

    2017-08-01

    Full Text Available In this work, a compact system for the automatic estimation of the tilt angle at any location of the world is presented. The system components are one computer, one GPS receiver and one Python program. The tilt angle is calculated through the maximization of the flux of direct radiation incident upon a flat solar collector. An estimation of the adjustments of this angle at different time periods are obtained. This angle is calculated in steps of six minutes during a whole year. Daily, monthly, biannually and yearly averages of this value are obtained. A comparison of the energetic gain when the tilt angle changes at the different time periods is made as well. Because, the algorithm doesn’t receive as an input the solar radiation incident upon a surface at the location of the calculation, a comparison was made between the results obtained and the results reported for the monthly tilt angle of 22 different places. The root mean square error obtained with this comparison was between 1.5 and 9.5 degrees. The monthly tilt angle estimated deviated in average for less than 6.3° with respect to the values reported for the different locations. Finally, the application of a correction factor in the monthly estimated angles is proposed, which might increase the collected energy.

  10. Measurement of the angle gamma

    International Nuclear Information System (INIS)

    Aleksan, R.; Kayser, B.; Sphicas, P.

    1993-01-01

    The angle γ at least as defined in the Wolfenstein approximation is not completely out of reach of current or proposed dedicated B experiments. This conclusion certainly depends crucially on the assumed trigger and tagging efficiencies and also on the expected backgrounds. The work summarized here represents but a first step in the direction of extracting the third angle of the unitarity triangle. The theoretical developments during the workshop have resulted in a clearer understanding of the quantities studied. On the experimental side, new decay modes (i.e. in addition to the traditional ρK s decay) have resulted in expections for observing CP violation in B s decays which are not unreasonable. It is conceivable that a dedicated B experiment can probe a fundamental aspect of the Standard Model, the CKM matrix, in multiple ways. In the process, new physics can appear anywhere along the line

  11. Contact angles on stretched solids

    Science.gov (United States)

    Mensink, Liz; Snoeijer, Jacco

    2017-11-01

    The surface energy of solid interfaces plays a central role in wetting, as they dictate the liquid contact angle. Yet, it has been challenging to measure the solid surface energies independently, without making use of Young's law. Here we present Molecular Dynamics (MD) simulations by which we measure the surface properties for all interfaces, including the solids. We observe change in contact angles upon stretching the solid substrates, showing that the surface energy is actually strain dependent. This is clear evidence of the so-called Shuttleworth effect, making it necessary to distinguish surface energy from surface tension. We discuss how this effect gives rise to a new class of elasto-capillary phenomena. ERC Consolidator Grant No. 616918.

  12. LHC Report: playing with angles

    CERN Multimedia

    Mike Lamont for the LHC team

    2016-01-01

    Ready (after a machine development period), steady (running), go (for a special run)!   The crossing angles are an essential feature of the machine set-up. They have to be big enough to reduce the long-range beam-beam effect. The LHC has recently enjoyed a period of steady running and managed to set a new record for “Maximum Stable Luminosity Delivered in 7 days” of 3.29 fb-1 between 29 August and 4 September. The number of bunches per beam remains pegged at 2220 because of the limitations imposed by the SPS beam dump. The bunch population is also somewhat reduced due to outgassing near one of the injection kickers at point 8. Both limitations will be addressed during the year-end technical stop, opening the way for increased performance in 2017. On 10 and 11 September, a two day machine development (MD) period took place. The MD programme included a look at the possibility of reducing the crossing angle at the high-luminosity interaction points. The crossing angles are an ess...

  13. Ocular biometry in angle closure.

    Science.gov (United States)

    Razeghinejad, Mohammad Reza; Banifatemi, Mohammad

    2013-01-01

    To compare ocular biometric parameters in primary angle closure suspects (PACS), primary angle closure glaucoma (PACG) and acute primary angle closure (APAC). This cross-sectional study was performed on 113 patients including 33 cases of PACS, 45 patients with PACG and 35 subjects with APAC. Central corneal thickness (CCT), axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) were measured with an ultrasonic biometer. Lens-axial length factor (LAF), relative lens position, corrected ACD (CACD) and corrected lens position were calculated. The parameters were measured bilaterally but only data from the right eyes were compared. In the APAC group, biometric parameters were also compared between affected and unaffected fellow eyes. Logistic regression analysis was performed to identify risk factors. No statistically significant difference was observed in biometric parameters between PACS and PACG eyes, or between affected and fellow eyes in the APAC group (P>0.05 for all comparisons). However, eyes with APAC had thicker cornea (P=0.001), thicker lens (PAPAC. In the APAC group, LAF (PAPAC.

  14. Light Scattering at Various Angles

    Science.gov (United States)

    Latimer, Paul; Pyle, B. E.

    1972-01-01

    The Mie theory of scattering is used to provide new information on how changes in particle volume, with no change in dry weight, should influence light scattering for various scattering angles and particle sizes. Many biological cells (e.g., algal cells, erythrocytes) and large subcellular structures (e.g., chloroplasts, mitochondria) in suspension undergo this type of reversible volume change, a change which is related to changes in the rates of cellular processes. A previous study examined the effects of such volume changes on total scattering. In this paper scattering at 10° is found to follow total scattering closely, but scattering at 45°, 90°, 135°, and 170° behaves differently. Small volume changes can cause very large observable changes in large angle scattering if the sample particles are uniform in size; however, the natural particle size heterogeneity of most samples would mask this effect. For heterogeneous samples of most particle size ranges, particle shrink-age is found to increase large angle scattering. PMID:4556610

  15. Angle comparison using an autocollimator

    Science.gov (United States)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Measurement of two-dimensional small angle deviation with a prism interferometer

    International Nuclear Information System (INIS)

    Chatterjee, Sanjib; Kumar, Y. Pavan

    2008-01-01

    A new technique for the measurement of two-dimensional small angular deviation is presented. A compound prism, which effectively produces a combination of two right-angled prisms in orthogonal directions, and plane reference surfaces have been utilized for the measurement of the orthogonal components of the angular tilt of an incident plane wavefront. Each orthogonal component of the angular tilt is separately measured from the angular rotation of the resultant wedge fringes between two plane wavefronts generated due to splitting of the incident plane wavefront by the corresponding set of right-angled prism and plane reference surface. The technique is shown to have high sensitivity for the measurement of small angle deviation. A monolithic prism interferometer, which is practically insensitive to vibration, is also proposed. Results obtained for the measurement of a known tilt angle are presented

  17. Acute incidents during anaesthesia

    African Journals Online (AJOL)

    Incidents can occur during induction, maintenance and emergence from anaesthesia. The following acute critical incidents are discussed in this article: • Anaphylaxis. • Aspiration ..... Already used in South Africa and Malawi, a scale-up of the technique is under way in Tanzania, Rwanda and Ghana. The report found that.

  18. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  19. Neutron elastic scattering at very small angles

    CERN Multimedia

    2002-01-01

    This experiment will measure neutron-proton elastic scattering at very small angles and hence very small four-momentum transfer, |t|. The range of |t| depends on the incident neutron momentum of the events but the geometrical acceptance will cover the angular range 0.025 < $\\Theta_{lab}$ < 1.9 mrad. The higher figure could be extended to 8.4 mrad by changing the geometry of the experiment in a later phase. \\\\ \\\\ The neutron beam will be highly collimated and will be derived from a 400 GeV external proton beam of up to $4 \\times 10^{10}$ protons per pulse in the SPS North Area Hall 1. The hydrogen target will be gaseous, operating at 40 atm. pressure and acts as a multiwire proportional chamber to detect the recoil protons. The forward neutron will be detected and located by interaction in a neutron vertex detector and its energy measured by a conventional steel plate calorimeter. \\\\ \\\\ The experiment will cover the angular region of nucleon-nucleon scattering which is dominated by Coulomb scattering ...

  20. Iris melanoma invading the camerular angle

    International Nuclear Information System (INIS)

    Verona Ugando, Leticia; Landrian Iglesias, Beatriz; Padierne Gonzalez, Naysa

    2011-01-01

    Uveal melanomas are the most frequent primary uveal tumors, having an incidence of 8/1 000 000 a year in Caucasian people. Specifically, iris Melanoma represents 5 to 7 % of the uveal malignant melanomas and they may be amelanic or pigmented, generally very vascularized. An eighteen years old male patient with a history of health problems was presented, who had been seen at the Ophthalmological Emergency Service because of eye pain and sudden visual reduction in his right eye. In the physical exam, a marked ocular hypertension was confirmed as well as a 2 mm hyphema and corneal edema. These conditions were overcome with treatment and afterwards, there was observed iris tumoration invading the iridocorneal angle. Some complementary studies were carried out to search further tumors at other levels and finally a fine needle aspiration biopsy was performed. The diagnosis was amelanic Iris Melanoma invading the ciliary body. The patient was referred for surgical treatment at the National Institute of Oncology and Radiology

  1. Uncertainty incorporated beam angle optimization for IMPT treatment planning.

    Science.gov (United States)

    Cao, Wenhua; Lim, Gino J; Lee, Andrew; Li, Yupeng; Liu, Wei; Ronald Zhu, X; Zhang, Xiaodong

    2012-08-01

    Beam angle optimization (BAO) by far remains an important and challenging problem in external beam radiation therapy treatment planning. Conventional BAO algorithms discussed in previous studies all focused on photon-based therapies. Impact of BAO on proton therapy is important while proton therapy increasingly receives great interests. This study focuses on potential benefits of BAO on intensity-modulated proton therapy (IMPT) that recently began available to clinical cancer treatment. The authors have developed a novel uncertainty incorporated BAO algorithm for IMPT treatment planning in that IMPT plan quality is highly sensitive to uncertainties such as proton range and setup errors. A linear programming was used to optimize robust intensity maps to scenario-based uncertainties for an incident beam angle configuration. Unlike conventional intensity-modulated radiation therapy with photons (IMXT), the search space for IMPT treatment beam angles may be relatively small but optimizing an IMPT plan may require higher computational costs due to larger data size. Therefore, a deterministic local neighborhood search algorithm that only needs a very limited number of plan objective evaluations was used to optimize beam angles in IMPT treatment planning. Three prostate cancer cases and two skull base chordoma cases were studied to demonstrate the dosimetric advantages and robustness of optimized beam angles from the proposed BAO algorithm. Two- to four-beam plans were optimized for prostate cases, and two- and three-beam plans were optimized for skull base cases. By comparing plans with conventional two parallel-opposed angles, all plans with optimized angles consistently improved sparing at organs at risks, i.e., rectum and femoral heads for prostate, brainstem for skull base, in either nominal dose distribution or uncertainty-based dose distributions. The efficiency of the BAO algorithm was demonstrated by comparing it with alternative methods including simulated

  2. Wide steering angle microscanner based on curved surface

    Science.gov (United States)

    Sabry, Yasser; Khalil, Diaa; Saadany, Bassam; Bourouina, Tarik

    2013-03-01

    Intensive industrial and academic research is oriented towards the design and fabrication of optical beam steering systems based on MEMS technology. In most of these systems, the scanning is achieved by rotating a flat micromirror around a central axis in which the main challenge is achieving a wide mirror rotation angle. In this work, a novel method of optical beam scanning based on reflection from a curved surface is presented. The scanning occurs when the optical axis of the curved surface is displaced with respect to the optical axis of the incident beam. To overcome the possible deformation of the spot with the scanning angle, the curved surface is designed with a specific aspherical profile. Moreover, the scanning exhibits a more linearized scanning angle-displacement relation than the conventional spherical profile. The presented scanner is fabricated using DRIE technology on an SOI wafer. The curved surface (reflector) is metalized and attached to a comb-drive actuator fabricated in the same lithography step. A single-mode fiber, behaving as a Gaussian beam source, is positioned on the substrate facing the mirror. The reflected optical beam angle and spotsize in the far field is recorded versus the relative shift between the fiber and the curved mirror. The spot size is plotted versus the scanning angle and a scanning spot size uniformity of about +/-10% is obtained for optical deflection angles up to 100 degrees. As the optical beam is propagating parallel to the wafer substrate, a completely integrated laser scanner can be achieved with filters and actuators self-aligned on the same chip that allows low cost and mass production of this important product.

  3. Survival probability in small angle scattering of low energy alkali ions from alkali covered metal surfaces

    International Nuclear Information System (INIS)

    Neskovic, N.; Ciric, D.; Perovic, B.

    1982-01-01

    The survival probability in small angle scattering of low energy alkali ions from alkali covered metal surfaces is considered. The model is based on the momentum approximation. The projectiles are K + ions and the target is the (001)Ni+K surface. The incident energy is 100 eV and the incident angle 5 0 . The interaction potential of the projectile and the target consists of the Born-Mayer, the dipole and the image charge potentials. The transition probability function corresponds to the resonant electron transition to the 4s projectile energy level. (orig.)

  4. Angle-dependent bandgap engineering in gated graphene superlattices

    Energy Technology Data Exchange (ETDEWEB)

    García-Cervantes, H.; Sotolongo-Costa, O. [Centro de Investigación en Ciencias, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Gaggero-Sager, L. M. [CIICAp, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Naumis, G. G. [Instituto Física, Depto. de Física-Química, Universidad Nacional Autónoma de México (UNAM). Apdo. Postal 20-364, 01000, México D.F., México (Mexico); Rodríguez-Vargas, I., E-mail: isaac@fisica.uaz.edu.mx [Centro de Investigación en Ciencias, IICBA, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, 62209 Cuernavaca, Morelos, México (Mexico); Unidad Académica de Física, Universidad Autónoma de Zacatecas, Calzada Solidaridad Esquina Con Paseo La Bufa S/N, 98060 Zacatecas, Zac., México (Mexico)

    2016-03-15

    Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results show that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.

  5. Ocular Biometry in Angle Closure

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2013-01-01

    Full Text Available Purpose: To compare ocular biometric parameters in primary angle closure suspects (PACS, primary angle closure glaucoma (PACG and acute primary angle closure (APAC. Methods: This cross-sectional study was performed on 113 patients including 33 cases of PACS, 45 patients with PACG and 35 subjects with APAC. Central corneal thickness (CCT, axial length (AL, anterior chamber depth (ACD and lens thickness (LT were measured with an ultrasonic biometer. Lens-axial length factor (LAF, relative lens position, corrected ACD (CACD and corrected lens position were calculated. The parameters were measured bilaterally but only data from the right eyes were compared. In the APAC group, biometric parameters were also compared between affected and unaffected fellow eyes. Logistic regression analysis was performed to identify risk factors. Results: No statistically significant difference was observed in biometric parameters between PACS and PACG eyes, or between affected and fellow eyes in the APAC group (P>0.05 for all comparisons. However, eyes with APAC had thicker cornea (P=0.001, thicker lens (P<0.0001, shallower ACD (P=0.009, shallower CACD (P=0.003 and larger LAF (P<0.0001. Based on ROC curve analysis, lower ACD, and larger LT, LAF and CCT values were associated with APAC. In the APAC group, LAF (P<0.0001 and CCT (P=0.001 were significant risk factors. Conclusion: This study revealed no significant difference in biometric characteristics in eyes with PACS and PACG. However, larger LAF and CCT were predictive of APAC.

  6. Small angle scattering and polymers

    Energy Technology Data Exchange (ETDEWEB)

    Cotton, J.P. [Laboratoire Leon Brillouin (LLB) - Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France)

    1996-12-31

    The determination of polymer structure is a problem of interest for both statistical physics and industrial applications. The average polymer structure is defined. Then, it is shown why small angle scattering, associated with isotopic substitution, is very well suited to the measurement of the chain conformation. The corresponding example is the old, but pedagogic, measurement of the chain form factor in the polymer melt. The powerful contrast variation method is illustrated by a recent determination of the concentration profile of a polymer interface. (author) 12 figs., 48 refs.

  7. Enhanced and switchable spin Hall effect of light near the Brewster angle on reflection

    International Nuclear Information System (INIS)

    Luo Hailu; Zhou Xinxing; Shu Weixing; Wen Shuangchun; Fan Dianyuan

    2011-01-01

    We theorize an enhanced and switchable spin Hall effect (SHE) of light near the Brewster angle on reflection and demonstrate it experimentally. The obtained spin-dependent splitting reaches 3200 nm near the Brewster angle, which is 50 times larger than the previously reported values in refraction. We find that the amplifying factor in weak measurement is not a constant, which is significantly different from that in refraction. As an analogy of SHE in an electronic system, a switchable spin accumulation in SHE of light is detected. We were able to switch the direction of the spin accumulations by slightly adjusting the incident angle.

  8. Graded index and randomly oriented core-shell silicon nanowires for broadband and wide angle antireflection

    Directory of Open Access Journals (Sweden)

    P. Pignalosa

    2011-09-01

    Full Text Available Antireflection with broadband and wide angle properties is important for a wide range of applications on photovoltaic cells and display. The SiOx shell layer provides a natural antireflection from air to the Si core absorption layer. In this work, we have demonstrated the random core-shell silicon nanowires with both broadband (from 400nm to 900nm and wide angle (from normal incidence to 60º antireflection characteristics within AM1.5 solar spectrum. The graded index structure from the randomly oriented core-shell (Air/SiOx/Si nanowires may provide a potential avenue to realize a broadband and wide angle antireflection layer.

  9. Rubber hand illusion affects joint angle perception.

    Directory of Open Access Journals (Sweden)

    Martin V Butz

    Full Text Available The Rubber Hand Illusion (RHI is a well-established experimental paradigm. It has been shown that the RHI can affect hand location estimates, arm and hand motion towards goals, the subjective visual appearance of the own hand, and the feeling of body ownership. Several studies also indicate that the peri-hand space is partially remapped around the rubber hand. Nonetheless, the question remains if and to what extent the RHI can affect the perception of other body parts. In this study we ask if the RHI can alter the perception of the elbow joint. Participants had to adjust an angular representation on a screen according to their proprioceptive perception of their own elbow joint angle. The results show that the RHI does indeed alter the elbow joint estimation, increasing the agreement with the position and orientation of the artificial hand. Thus, the results show that the brain does not only adjust the perception of the hand in body-relative space, but it also modifies the perception of other body parts. In conclusion, we propose that the brain continuously strives to maintain a consistent internal body image and that this image can be influenced by the available sensory information sources, which are mediated and mapped onto each other by means of a postural, kinematic body model.

  10. Determination of angle of light deflection in higher-derivative gravity theories

    Science.gov (United States)

    Xu, Chenmei; Yang, Yisong

    2018-03-01

    Gravitational light deflection is known as one of three classical tests of general relativity and the angle of deflection may be computed explicitly using approximate or exact solutions describing the gravitational force generated from a point mass. In various generalized gravity theories, however, such explicit determination is often impossible due to the difficulty in obtaining an exact expression for the deflection angle. In this work, we present some highly effective globally convergent iterative methods to determine the angle of semiclassical gravitational deflection in higher- and infinite-derivative formalisms of quantum gravity theories. We also establish the universal properties that the deflection angle always stays below the classical Einstein angle and is a strictly decreasing function of the incident photon energy, in these formalisms.

  11. Angle closure glaucoma in the Northern Ireland Diabetic Retinopathy Screening Programme.

    Science.gov (United States)

    Lagan, M A; O'Gallagher, M K; Johnston, S E; Hart, P M

    2016-08-01

    PurposeTo ascertain the risk of angle closure glaucoma associated with mydriasis in the Northern Ireland Diabetic Retinopathy Screening Programme.MethodsA retrospective case note review was carried out, cross referencing hospital records with those of the screening programme, to identify episodes of angle closure glaucoma, which occurred within 14 days of a retinopathy screening episode involving pharmacological mydriasis.ResultsThree cases of angle closure following mydriasis for screening were identified. The incidence of angle closure within the screening programme was calculated to be 1 in 31 755 patients dilated or 0.75 patients per year.ConclusionAngle closure is a rare complication of mydriasis used in photographic screening for diabetic retinopathy. We advocate the provision of clear instructions to patients in screening programmes on when and how to access emergency ophthalmic care following dilation to prevent loss of vision in this rare event.

  12. Contact Angle Measurement in Lattice Boltzmann Method

    OpenAIRE

    Wen, Binghai; Huang, Bingfang; Qin, Zhangrong; Wang, Chunlei; Zhang, Chaoying

    2017-01-01

    Contact angle is an essential characteristic in wetting, capillarity and moving contact line; however, although contact angle phenomena are effectively simulated, an accurate and real-time measurement for contact angle has not been well studied in computational fluid dynamics, especially in dynamic environments. Here, we design a geometry-based mesoscopic scheme to onthesport measure the contact angle in the lattice Boltzmann method. The computational results without gravity effect are in exc...

  13. Empirical angle-dependent Biot and MBA models for acoustic anisotropy in cancellous bone

    International Nuclear Information System (INIS)

    Lee, Kang ll; Hughes, E R; Humphrey, V F; Leighton, T G; Choi, Min Joo

    2007-01-01

    The Biot and the modified Biot-Attenborough (MBA) models have been found useful to understand ultrasonic wave propagation in cancellous bone. However, neither of the models, as previously applied to cancellous bone, allows for the angular dependence of acoustic properties with direction. The present study aims to account for the acoustic anisotropy in cancellous bone, by introducing empirical angle-dependent input parameters, as defined for a highly oriented structure, into the Biot and the MBA models. The anisotropy of the angle-dependent Biot model is attributed to the variation in the elastic moduli of the skeletal frame with respect to the trabecular alignment. The angle-dependent MBA model employs a simple empirical way of using the parametric fit for the fast and the slow wave speeds. The angle-dependent models were used to predict both the fast and slow wave velocities as a function of propagation angle with respect to the trabecular alignment of cancellous bone. The predictions were compared with those of the Schoenberg model for anisotropy in cancellous bone and in vitro experimental measurements from the literature. The angle-dependent models successfully predicted the angular dependence of phase velocity of the fast wave with direction. The root-mean-square errors of the measured versus predicted fast wave velocities were 79.2 m s -1 (angle-dependent Biot model) and 36.1 m s -1 (angle-dependent MBA model). They also predicted the fact that the slow wave is nearly independent of propagation angle for angles about 50 0 , but consistently underestimated the slow wave velocity with the root-mean-square errors of 187.2 m s -1 (angle-dependent Biot model) and 240.8 m s -1 (angle-dependent MBA model). The study indicates that the angle-dependent models reasonably replicate the acoustic anisotropy in cancellous bone

  14. 30 CFR 56.19037 - Fleet angles.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fleet angles. 56.19037 Section 56.19037 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Sheaves § 56.19037 Fleet angles. Fleet angles on hoists installed after November 15, 1979, shall not be...

  15. 30 CFR 57.19037 - Fleet angles.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fleet angles. 57.19037 Section 57.19037 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Sheaves § 57.19037 Fleet angles. Fleet angles on hoists installed after November 15, 1979, shall not be...

  16. Lateral angle and cranial base sexual dimorphism

    DEFF Research Database (Denmark)

    Duquesnel Mana, Mathilde; Adalian, Pascal; Lynnerup, Niels

    2016-01-01

    , to examine sexual dimorphism in the relationship between the lateral angle and cranial base shape. The lateral angle method was tested using a forensic sample of 102 CT scans of the head with known sex. We measured the angle using two methods: measurements directly on the CT slide, the method usually applied...

  17. Small-angle scattering, topography and radiography

    International Nuclear Information System (INIS)

    Schelten, J.

    1978-01-01

    A table is given showing scattering and imaging methods for X-rays and neutrons, followed, by a discussion of such topics as 1. Radiography 2. Topography 3. Small-angle scattering 3.1. The differential cross section 3.2. Comparison of X-ray and neutron small-angle scattering 3.3. Examples of small-angle scattering. (orig.) [de

  18. Critical incident stress management.

    Science.gov (United States)

    Lim, J J; Childs, J; Gonsalves, K

    2000-10-01

    Recent studies have indicated implementation of the CISM Program has impacted and reduced the cost of workers' compensation claims for stress related conditions and the number of lost work days (Ott, 1997; Western Management Consultants, 1996). Occupational health professionals need to be ready to develop and implement a comprehensive critical incident stress management process in anticipation of a major event. The ability to organize, lead, or administer critical incident stress debriefings for affected employees is a key role for the occupational health professional. Familiarity with these concepts and the ability to identify a critical incident enhances value to the business by mitigating the stress and impact to the workplace. Critical Incident Stress Management Systems have the potential for decreasing stress and restoring employees to normal life function--a win/win situation for both the employees and the organization.

  19. Marine Animal Incident Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Large whale stranding, death, ship strike and entanglement incidents are all recorded to monitor the health of each population and track anthropogenic factors that...

  20. Police Incident Blotter (Archive)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Police Blotter Archive contains crime incident data after it has been validated and processed to meet Uniform Crime Reporting (UCR) standards, published on a...

  1. Prediction of Safety Incidents

    Data.gov (United States)

    National Aeronautics and Space Administration — Safety incidents, including injuries, property damage and mission failures, cost NASA and contractors thousands of dollars in direct and indirect costs. This project...

  2. 2011 Japanese Nuclear Incident

    Science.gov (United States)

    EPA’s RadNet system monitored the environmental radiation levels in the United States and parts of the Pacific following the Japanese Nuclear Incident. Learn about EPA’s response and view historical laboratory data and news releases.

  3. GALAXI: Gallium anode low-angle x-ray instrument

    Directory of Open Access Journals (Sweden)

    Emmanuel Kentzinger

    2016-03-01

    Full Text Available The high brilliance laboratory small angle X-ray scattering instrument GALAXI, which is operated by JCNS, Forschungszentrum Jülich, permits the investigation of chemical correlations in bulk materials or of structures deposited on a surface at nanometre and mesoscopic length scales. The instrument is capable to perform GISAXS experiments in reflection at grazing incidence as well as SAXS experiments in transmission geometry. The X-ray flux on sample is comparable or higher than the one obtained at a comparable beamline at a second generation synchrotron radiation source.

  4. Information Security Incident Management

    Directory of Open Access Journals (Sweden)

    D. I. Persanov

    2010-03-01

    Full Text Available The present report highlights the points of information security incident management in an enterprise. Some aspects of the incident and event classification are given. The author presents his view of the process scheme over the monitoring and processing information security events. Also, the report determines a few critical points of the listed process and gives the practical recommendations over its development and optimization.

  5. Quasi-specular reflection of cold neutrons from nano-dispersed media at above-critical angles

    International Nuclear Information System (INIS)

    Cubitt, R.; Lychagin, E.V.; Muzychka, A.Yu.; Nekhaev, G.V.; Nesvizhevsky, V.V.; Pignol, G.; Protasov, K.V.; Strelkov, A.V.

    2010-01-01

    We have predicted and observed for the first time a new phenomenon of quasi-specular reflection of cold neutrons at small incidence angles from nano-dispersed media. this is due to multiple small-angle scattering of neutrons from nano-sized inhomogeneities in the scattering potential. The reflection angle as well as the half-width of angular distribution of diffusively reflected neutrons is approximately equal to the incidence angle. For the powder of diamond nanoparticles used, the reflection probability was equal to ∼30% within the detector angular size, which corresponds to 40-50% of total probability (albedo) of quasi-specular reflection. The tangential velocity component of incident neutrons was up to an order of magnitude larger than the critical velocity for pure diamond. We provide an example of potential application of the discovered phenomenon for increasing cold neutron fluxes available for experiments.

  6. Wide-angle light-trapping electrode for photovoltaic cells.

    Science.gov (United States)

    Omelyanovich, Mikhail M; Simovski, Constantin R

    2017-10-01

    In this Letter, we experimentally show that a submicron layer of a transparent conducting oxide that may serve a top electrode of a photovoltaic cell based on amorphous silicon when properly patterned by notches becomes an efficient light-trapping structure. This is so for amorphous silicon thin-film solar cells with properly chosen thicknesses of the active layers (p-i-n structure with optimal thicknesses of intrinsic and doped layers). The nanopatterned layer of transparent conducting oxide reduces both the light reflectance from the photovoltaic cell and transmittance through the photovoltaic layers for normal incidence and for all incidence angles. We explain the physical mechanism of our light-trapping effect, prove that this mechanism is realized in our structure, and show that the nanopatterning is achievable in a rather easy and affordable way that makes our method of solar cell enhancement attractive for industrial adaptations.

  7. Surface properties of dental polymers: measurements of contact angles, roughness and fluoride release

    Directory of Open Access Journals (Sweden)

    Fátima Namen

    2008-09-01

    Full Text Available OBJECTIVE: Earlier studies on some dental materials measured roughness and/or contact angles or fluoride release separately. In the present study, five dental polymers were investigated to ascertain their contact angles, wettability, roughness, and fluoride release in dry or wet conditions. METHODS: Samples for 5 materials were prepared and stored dry or wet in deionized water pH 6.8. Samples were submitted to finishing/polishing procedures, and the measurements in Goniometer, roughness (µm and fluoride analysis RESULTS AND CONCLUSIONS: Except for the Ariston pHc, all the materials displayed high contact angles when measured with water, showing hydrophobic characteristics. Roughness changed the contact angles, especially those of Ariston (α < 0.05. Fluoride did not modify the contact angles, but increased the roughness of the finished material.

  8. The Q-angle and sport

    DEFF Research Database (Denmark)

    Hahn, Thomas; Foldspang, Anders

    1997-01-01

    Quadriceps muscle contraction tends to straighten the Q angle. We expected that sports comprising a high amount of quadriceps training could be associated with low Q angles. The aim of the present study was to estimate the Q angle in athletes and to investigate its potential associations with par......Quadriceps muscle contraction tends to straighten the Q angle. We expected that sports comprising a high amount of quadriceps training could be associated with low Q angles. The aim of the present study was to estimate the Q angle in athletes and to investigate its potential associations...... with participation in sport. Three hundred and thirty-nine athletes had their Q angle measured. The mean of right-side Q angles was higher than left side, and the mean Q angle was higher in women than in men. The Q angle was positively associated with years of jogging, and negatively with years of soccer, swimming...... and sports participation at all. It is concluded that the use of Q angle measurements is questionable....

  9. Individualized optimal release angles in discus throwing.

    Science.gov (United States)

    Leigh, Steve; Liu, Hui; Hubbard, Mont; Yu, Bing

    2010-02-10

    The purpose of this study was to determine individualized optimal release angles for elite discus throwers. Three-dimensional coordinate data were obtained for at least 10 competitive trials for each subject. Regression relationships between release speed and release angle, and between aerodynamic distance and release angle were determined for each subject. These relationships were linear with subject-specific characteristics. The subject-specific relationships between release speed and release angle may be due to subjects' technical and physical characteristics. The subject-specific relationships between aerodynamic distance and release angle may be due to interactions between the release angle, the angle of attack, and the aerodynamic distance. Optimal release angles were estimated for each subject using the regression relationships and equations of projectile motion. The estimated optimal release angle was different for different subjects, and ranged from 35 degrees to 44 degrees . The results of this study demonstrate that the optimal release angle for discus throwing is thrower-specific. The release angles used by elite discus throwers in competition are not necessarily optimal for all discus throwers, or even themselves. The results of this study provide significant information for understanding the biomechanics of discus throwing techniques. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. Wafer scale oblique angle plasma etching

    Science.gov (United States)

    Burckel, David Bruce; Jarecki, Jr., Robert L.; Finnegan, Patrick Sean

    2017-05-23

    Wafer scale oblique angle etching of a semiconductor substrate is performed in a conventional plasma etch chamber by using a fixture that supports a multiple number of separate Faraday cages. Each cage is formed to include an angled grid surface and is positioned such that it will be positioned over a separate one of the die locations on the wafer surface when the fixture is placed over the wafer. The presence of the Faraday cages influences the local electric field surrounding each wafer die, re-shaping the local field to be disposed in alignment with the angled grid surface. The re-shaped plasma causes the reactive ions to follow a linear trajectory through the plasma sheath and angled grid surface, ultimately impinging the wafer surface at an angle. The selected geometry of the Faraday cage angled grid surface thus determines the angle at with the reactive ions will impinge the wafer.

  11. On-line determination of the grain angle using ellipse analysis of the laser light scattering pattern image

    International Nuclear Information System (INIS)

    Hu, C.; Tanaka, C.; Ohtani, T.

    2004-01-01

    Under fixed cutting conditions, the surface finish roughness is correlated to the grain angle. However, the means of determining the grain angle automatically and accurately is still a challenge for on-line control of the router. It is therefore necessary to develop a new technology to determine the grain angle accurately and automatically. In this research, a laser light scattering pattern was used to accurately determine the grain angle. The light scattering pattern image was a quasi-ellipse caused by the grain direction and tracheid effect. A new modified Hough transform ellipse analysis technology was adopted to determine the ellipse parameters that could be used to determine the grain angle. The results indicated that the measured grain angle using the method proposed here was accurate and effective. The measured gain angle coincided with the real grain angle. There was an insignificant difference between the measured grain angle of Japanese beech (Fagus crenata blume) and that of sugi (Cryptomeria japonica D.Don) under two machining conditions that gave planed or sawn finishes. However, the accuracy of the measured grain angle of sugi was better than that of Japanese beech for the planed finish, the accuracy of the measured grain angle of Japanese beech was better than that of sugi for the sawn finish, and the accuracy of the measured grain angle for planed samples was better than that for sawn samples of both sugi and Japanese beech

  12. Control of ordered mesoporous titanium dioxide nanostructures formed using plasma enhanced glancing angle deposition

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, Des [Institute of Thin Films, Sensors & Imaging, Scottish Universities Physics Alliance, University of West of Scotland, Paisley, PA1 2BE (United Kingdom); Child, David, E-mail: david.child@uws.ac.uk [Institute of Thin Films, Sensors & Imaging, Scottish Universities Physics Alliance, University of West of Scotland, Paisley, PA1 2BE (United Kingdom); Song, Shigeng; Zhao, Chao [Institute of Thin Films, Sensors & Imaging, Scottish Universities Physics Alliance, University of West of Scotland, Paisley, PA1 2BE (United Kingdom); Alajiani, Yahya [Institute of Thin Films, Sensors & Imaging, Scottish Universities Physics Alliance, University of West of Scotland, Paisley, PA1 2BE (United Kingdom); Department of Physics, Faculty of Science, Jazan University, Jazan (Saudi Arabia); Waddell, Ewan [Thin Film Solutions Ltd, West of Scotland Science Park, Glasgow, G20 0TH (United Kingdom)

    2015-10-01

    Three dimensional nanostructures of mesoporous (pore diameter between 2-50 nm) nanocrystalline titania (TiO{sub 2}) were produced using glancing angle deposition combined with plasma ion assisted deposition, providing plasma enhanced glancing angle deposition eliminating the need for post-annealing to achieve film crystallinity. Electron beam evaporation was chosen to deposit nanostructures at various azimuthal angles, achieving designed variation in three dimensional nanostructure. A thermionic broad beam hollow cathode plasma source was used to enhance electron beam deposition, with ability to vary in real time ion fluxes and energies providing a means to modify and control TiO{sub 2} nanostructure real time with controlled density and porosity along and lateral to film growth direction. Plasma ion assisted deposition was carried out at room temperature using a hollow cathode plasma source, ensuring low heat loading to the substrate during deposition. Plasma enhanced glancing angle TiO{sub 2} structures were deposited onto borosilicate microscope slides and used to characterise the effects of glancing angle and plasma ion energy distribution function on the optical and nanostructural properties. Variation in TiO{sub 2} refractive index from 1.40 to 2.45 (@ 550 nm) using PEGLAD is demonstrated. Results and analysis of the influence of plasma enhanced glancing angle deposition on evaporant path and resultant glancing angle deviation from standard GLAD are described. Control of mesoporous morphology is described, providing a means of optimising light trapping features and film porosity, relevant to applications such as fabrication of dye sensitised solar cells. - Highlights: • Plasma assistance during glancing angle deposition enables control of morphology. • Ion energy variation during glancing angle deposition varies columnar angle • Column thickness of glancing angle deposition dependant on ion current density • Ion current density variation during

  13. A method of directly extracting multiwave angle-domain common-image gathers

    Science.gov (United States)

    Han, Jianguang; Wang, Yun

    2017-10-01

    Angle-domain common-image gathers (ADCIGs) can provide an effective way for migration velocity analysis and amplitude versus angle analysis in oil-gas seismic exploration. On the basis of multi-component Gaussian beam prestack depth migration (GB-PSDM), an alternative method of directly extracting multiwave ADCIGs is presented in this paper. We first introduce multi-component GB-PSDM, where a wavefield separation is proceeded to obtain the separated PP- and PS-wave seismic records before migration imaging for multiwave seismic data. Then, the principle of extracting PP- and PS-ADCIGs using GB-PSDM is presented. The propagation angle can be obtained using the real-value travel time of Gaussian beam in the course of GB-PSDM, which can be used to calculate the incidence and reflection angles. Two kinds of ADCIGs can be extracted for the PS-wave, one of which is P-wave incidence ADCIGs and the other one is S-wave reflection ADCIGs. In this paper, we use the incident angle to plot the ADCIGs for both PP- and PS-waves. Finally, tests of synthetic examples show that the method introduced here is accurate and effective.

  14. Geometrically distributed one-dimensional photonic crystals for light-reflection in all angles.

    Science.gov (United States)

    Alagappan, G; Wu, P

    2009-07-06

    We demonstrate that a series of one-dimensional photonic crystals made of any dielectric materials, with the periods are distributed in a geometrical progression of a common ratio, r light of any spectral range. If an omni-directional reflection is desired for all polarizations and for all incident angles smaller than thetao, then r light reflection.

  15. Scanning laser reflection tool for alignment and period measurement of critical-angle transmission gratings

    Science.gov (United States)

    Song, Jungki; Heilmann, Ralf K.; Bruccoleri, Alexander R.; Hertz, Edward; Schatternburg, Mark L.

    2017-08-01

    We report progress toward developing a scanning laser reflection (LR) tool for alignment and period measurement of critical-angle transmission (CAT) gratings. It operates on a similar measurement principle as a tool built in 1994 which characterized period variations of grating facets for the Chandra X-ray Observatory. A specularly reflected beam and a first-order diffracted beam were used to record local period variations, surface slope variations, and grating line orientation. In this work, a normal-incidence beam was added to measure slope variations (instead of the angled-incidence beam). Since normal incidence reflection is not coupled with surface height change, it enables measurement of slope variations more accurately and, along with the angled-incidence beam, helps to reconstruct the surface figure (or tilt) map. The measurement capability of in-grating period variations was demonstrated by measuring test reflection grating (RG) samples that show only intrinsic period variations of the interference lithography process. Experimental demonstration for angular alignment of CAT gratings is also presented along with a custom-designed grating alignment assembly (GAA) testbed. All three angles were aligned to satisfy requirements for the proposed Arcus mission. The final measurement of roll misalignment agrees with the roll measurements performed at the PANTER x-ray test facility.

  16. Zero-crossing angle of the np analyzing power below 300 MeV

    International Nuclear Information System (INIS)

    Davis, C.A.; Abegg, R.; Berdoz, A.R.; Birchall, J.; Campbell, J.R.; Gan, L.; Green, P.W.; Greeniaus, L.G.; Helmer, R.; Korkmaz, E.; Li, J.; Miller, C.A.; Opper, A.K.; Page, S.A.; Ramsay, W.D.; Sekulovich, A.M.; Sum, V.; van Oers, W.T.H.; Zhao, J.

    1995-01-01

    The zero point of the analyzing power for neutron-proton scattering has been measured as a function of scattering angle for 4 incident neutron energies, 174.3, 202.4, 216.5, and 260.3 MeV. The accuracy is ±0.25 degree

  17. Zero-crossing angle of the {ital np} analyzing power below 300 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Davis, C.A. [TRIUMF, 4004 Wesbrook Mall, Vancouver, B.C., V6T 2A3 (Canada)]|[University of Manitoba, Department of Physics, Winnipeg, MB, R3T 2N2 (Canada); Abegg, R. [TRIUMF, 4004 Wesbrook Mall, Vancouver, B.C., V6T 2A3 (Canada)]|[University of Alberta, Department of Physics, Edmonton, AB, T6G 2N5 (Canada); Berdoz, A.R.; Birchall, J.; Campbell, J.R.; Gan, L. [University of Manitoba, Department of Physics, Winnipeg, MB, R3T 2N2 (Canada); Green, P.W.; Greeniaus, L.G. [University of Alberta, Department of Physics, Edmonton, AB, T6G 2N5 (Canada); Helmer, R. [TRIUMF, 4004 Wesbrook Mall, Vancouver, B.C., V6T 2A3 (Canada); Korkmaz, E.; Li, J. [University of Alberta, Department of Physics, Edmonton, AB, T6G 2N5 (Canada); Miller, C.A. [TRIUMF, 4004 Wesbrook Mall, Vancouver, B.C., V6T 2A3 (Canada); Opper, A.K. [University of Alberta, Department of Physics, Edmonton, AB, T6G 2N5 (Canada); Page, S.A.; Ramsay, W.D.; Sekulovich, A.M.; Sum, V.; van Oers, W.T.H.; Zhao, J. [University of Manitoba, Department of Physics, Winnipeg, MB, R3T 2N2 (Canada)

    1995-07-15

    The zero point of the analyzing power for neutron-proton scattering has been measured as a function of scattering angle for 4 incident neutron energies, 174.3, 202.4, 216.5, and 260.3 MeV. The accuracy is {plus_minus}0.25{degree}. (AIP)

  18. Cricket pace bowling: The trade-off between optimising knee angle ...

    African Journals Online (AJOL)

    Objective. To investigate the relationship between three-dimensional (3D) knee kinematics during pace bowling action, injury incidence and bowling performance at the start and end of a cricket season. Methods. Knee angle and ball release (BR) speed of injury-free premier league (club level) cricket pace bowlers over the ...

  19. Effect of finite sample dimensions and total scatter acceptance angle on the gamma ray buildup factor

    International Nuclear Information System (INIS)

    Singh, Sukhpal; Kumar, Ashok; Singh, Charanjeet; Thind, Kulwant Singh; Mudahar, Gurmel S.

    2008-01-01

    The simultaneous variation of gamma ray buildup factors with absorber thickness (up to 6.5 mfp) and total scatter acceptance angle (which is the sum of incidence and exit beam divergence) in the media of high volume flyash concrete and water was studied experimentally using a point isotropic 137 Cs source

  20. Atherosclerosis, C-reactive protein, and risk for open-angle glaucoma : The Rotterdam study

    NARCIS (Netherlands)

    de Voogd, Simone; Wolfs, Roger C. W.; Jansonius, Nomdo M.; Witteman, Jacqueline C. M.; Hofman, Albert; de Jong, Paulus T. V. M.

    PURPOSE. To test the hypotheses that atherosclerosis and elevated serum C-reactive protein ( CRP) levels are risk factors for open-angle glaucoma ( OAG). METHODS. In a prospective, population-based cohort study, all participants 55 years and older and at risk for incident OAG underwent, at baseline

  1. Atherosclerosis, C-reactive protein, and risk for open-angle glaucoma: The Rotterdam Study

    NARCIS (Netherlands)

    S. de Voogd (Simone); R.C.W. Wolfs (Roger); N.M. Jansonius (Nomdo); J.C.M. Witteman (Jacqueline); A. Hofman (Albert); P.T.V.M. de Jong (Paulus)

    2006-01-01

    textabstractPURPOSE. To test the hypotheses that atherosclerosis and elevated serum C-reactive protein (CRP) levels are risk factors for open-angle glaucoma (OAG). METHODS. In a prospective, population-based cohort study, all participants 55 years and older and at risk for incident OAG underwent, at

  2. Atherosclerosis, C-reactive protein, and risk for open-angle glaucoma: the Rotterdam study

    NARCIS (Netherlands)

    de Voogd, Simone; Wolfs, Roger C. W.; Jansonius, Nomdo M.; Witteman, Jacqueline C. M.; Hofman, Albert; de Jong, Paulus T. V. M.

    2006-01-01

    To test the hypotheses that atherosclerosis and elevated serum C-reactive protein (CRP) levels are risk factors for open-angle glaucoma (OAG). In a prospective, population-based cohort study, all participants 55 years and older and at risk for incident OAG underwent, at baseline (1990-1993) and at

  3. Radiation incidents in dentistry

    International Nuclear Information System (INIS)

    Lovelock, D.J.

    1996-01-01

    Most dental practitioners act as their own radiographer and radiologist, unlike their medical colleagues. Virtually all dental surgeons have a dental X-ray machine for intraoral radiography available to them and 40% of dental practices have equipment for dental panoramic tomography. Because of the low energy of X-ray equipment used in dentistry, radiation incidents tend to be less serious than those associated with other aspects of patient care. Details of 47 known incidents are given. The advent of the 1985 and 1988 Ionising Radiation Regulations has made dental surgeons more aware of the hazards of radiation. These regulations, and general health and safety legislation, have led to a few dental surgeons facing legal action. Because of the publicity associated with these court cases, it is expected that there will be a decrease in radiation incidents arising from the practice of dentistry. (author)

  4. Electromagnetic Power Harvester Using Wide-Angle and Polarization-Insensitive Metasurfaces

    Directory of Open Access Journals (Sweden)

    Xuanming Zhang

    2018-03-01

    Full Text Available A new wide-angle and polarization-insensitive metasurface (MS instead of traditional antenna is built as the primary ambient energy harvester in this paper. The MS is a two-dimensional energy harvesting array that is composed of subwavelength electrical small ring resonator that is working at 2.5 GHz (LTE/WiFi. In the case of different polarization and incidence angles, we demonstrate the metasurface can achieve high harvesting efficiency of 90%. The fabricated prototype of 9 × 9 MS energy harvesting array is measured, and the experimental results validate that the proposed MS has a good performance more than 80% of energy harvesting efficiency for arbitrary polarization and wide-angle incident waves. The good agreement of the simulation with the experiment results verifies the practicability and effectiveness of the proposed MS structure, which will provide a new source of supply in wireless sensor networks (WSN.

  5. Dielectric-based subwavelength metallic meanders for wide-angle band absorbers.

    Science.gov (United States)

    Shen, Su; Qiao, Wen; Ye, Yan; Zhou, Yun; Chen, Linsen

    2015-01-26

    We propose nano-meanders that can achieve wide-angle band absorption in visible regime. The nano-meander consists of a subwavelength dielectric grating covered by continuous ultra-thin Aluminum film (less than one tenth of the incident wavelength). The excited photonic resonant modes, such as cavity mode, surface plasmonic mode and Rayleigh-Wood anomaly, are discussed in detail. Nearly total resonant absorption due to funneling mechanism in the air nano-groove is almost invariant with large incident angle in transverse magnetic polarization. From both the structural geometry and the nanofabrication point of view, the light absorber has a very simple geometrical structure and it is easy to be integrated into complex photonic devices. The highly efficient angle-robust light absorber can be potential candidate for a range of passive and active photonic applications, including solar-energy harvesting as well as producing artificial colors on a large scale substrate.

  6. Reflection of X-rays from a rough surface at extremely small grazing angles.

    Science.gov (United States)

    Wen, Mingwu; Kozhevnikov, Igor V; Wang, Zhanshan

    2015-09-21

    Peculiarities of X-ray diffraction from a rough surface at an extremely small grazing angle of an incident beam are theoretically studied. The interrelation of four diffraction channels (coherent reflectance, coherent transmittance, diffuse scattering in vacuum, and scattering into the matter depth) is analyzed for different limiting cases (large and small correlation length of roughness and large and extremely small grazing angle of incident radiation). Both the Debye-Waller and the Nevot-Croce factors are demonstrated to describe improperly the features of X-ray diffraction at extremely small grazing angles. More appropriate simple analytic expressions for the specular reflectivity and total integrated scattering in vacuum are obtained instead. Transformation of one limiting diffraction regime into another one with variation in the correlation length of roughness is discussed.

  7. High angle of attack aerodynamics subsonic, transonic, and supersonic flows

    CERN Document Server

    Rom, Josef

    1992-01-01

    The aerodynamics of aircraft at high angles of attack is a subject which is being pursued diligently, because the modern agile fighter aircraft and many of the current generation of missiles must perform well at very high incidence, near and beyond stall. However, a comprehensive presentation of the methods and results applicable to the studies of the complex aerodynamics at high angle of attack has not been covered in monographs or textbooks. This book is not the usual textbook in that it goes beyond just presenting the basic theoretical and experimental know-how, since it contains reference material to practical calculation methods and technical and experimental results which can be useful to the practicing aerospace engineers and scientists. It can certainly be used as a text and reference book for graduate courses on subjects related to high angles of attack aerodynamics and for topics related to three-dimensional separation in viscous flow courses. In addition, the book is addressed to the aerodynamicist...

  8. Angle closure glaucoma secondary to psychotropic medications

    Directory of Open Access Journals (Sweden)

    John Ross Rocke

    2017-07-01

    Full Text Available Background Psychotropic medications are commonly associated anticholinergic side-effects. In susceptible patients, this can result in angle closure induced permanent loss of vision Aims To review the mechanism of angle closure and which psychotropics are most likely to precipitate this complication. Methods Literature review surrounding the mechanism of angle closure and pharmacology of various psychotropics Results Mydriasis, forward-displacement of the lens-iris diaphragm and ciliary body swelling are the mechanisms by which angle closure occurs. Anticholinergic side effects of psychotropic medications are most implicated in causing this. Conclusion Screening patients for risk factors of angle closure and either having them formally assessed or choosing psychotropics with minimal anticholinergic effects may avoid inducing angle closure.

  9. Incidents in nuclear installations

    International Nuclear Information System (INIS)

    Franzen, L.F.; Wienhold, W.

    1976-09-01

    With reference to the incident list of the Ministry for the period 1971-74, Prof. Bechert has expressed a lot of questions and statements in a letter to the Government. The letter is quoted in full. Inadequate conclusions drawn by Prof. Bechert in connection with quotations from daily newspapers and other documents are put right. (HP) [de

  10. Lightning incidents in Mongolia

    Directory of Open Access Journals (Sweden)

    Myagmar Doljinsuren

    2015-11-01

    Full Text Available This is one of the first studies that has been conducted in Mongolia on the distribution of lightning incidents. The study covers a 10-year period from 2004 to 2013. The country records a human death rate of 15.4 deaths per 10 million people per year, which is much higher than that of many countries with similar isokeraunic level. The reason may be the low-grown vegetation observed in most rural areas of Mongolia, a surface topography, typical to steppe climate. We suggest modifications to Gomes–Kadir equation for such countries, as it predicts a much lower annual death rate for Mongolia. The lightning incidents spread over the period from May to August with the peak of the number of incidents occurring in July. The worst lightning affected region in the country is the central part. Compared with impacts of other convective disasters such as squalls, thunderstorms and hail, lightning stands as the second highest in the number of incidents, human deaths and animal deaths. Economic losses due to lightning is only about 1% of the total losses due to the four extreme weather phenomena. However, unless precautionary measures are not promoted among the public, this figure of losses may significantly increase with time as the country is undergoing rapid industrialization at present.

  11. Fire Incident Reporting Manual

    Science.gov (United States)

    1984-02-01

    the result of an incident that requires (or should require) treatment by a practitioner of medicine , a registered emergency medical technician, or a...UNANNOUNCED AIRCRAFT EMERGENCYS ~~PRIOR TO TAKE OFF OR AFTERLADN 5 FUEL OPERATIONS REQUIRING 1AREING G A FIRE10 ARRESTING GEAR’BARRIER FR . ENGAGEMENTS AND

  12. Direct angle resolved photoemission spectroscopy and ...

    Indian Academy of Sciences (India)

    Keywords. Condensed matter physics; high-c superconductivity; electronic properties; photoemission spectroscopy; angle resolved photoemission spectroscopy; cuprates; films; strain; pulsed laser deposition.

  13. The qualitative criterion of transient angle stability

    DEFF Research Database (Denmark)

    Lyu, R.; Xue, Y.; Xue, F.

    2015-01-01

    In almost all the literatures, the qualitative assessment of transient angle stability extracts the angle information of generators based on the swing curve. As the angle (or angle difference) of concern and the threshold value rely strongly on the engineering experience, the validity and robust...... of these criterions are weak. Based on the stability mechanism from the extended equal area criterion (EEAC) theory and combining with abundant simulations of real system, this paper analyzes the criterions in most literatures and finds that the results could be too conservative or too optimistic. It is concluded...

  14. Contextual factors and social consequences of incident disease

    DEFF Research Database (Denmark)

    Christensen, Ulla; Kriegbaum, Margit; Hougaard, Charlotte Ørsted

    2008-01-01

    practice modify the employment effect of disease. We have studied risk of labour market exclusion following incident hospitalization for ischaemic heart disease (IHD), and whether this risk may be modified by contextual factors on the municipal level. Methods: A cohort design on a 10% random sample...... of the whole Danish population including individuals aged 43-60 years, (n = 516.454 person-years including 840 cases of IHD). The independent variable was incident hospitalization for IHD and outcome variable was defined as job loss 2 years after the event. Regional-level data included all the 275 Danish...

  15. Constituent quark masses from modified perturbative QCD

    Energy Technology Data Exchange (ETDEWEB)

    Cabo Montes de Oca, A. [Instituto de Cibernetica, Matematica y Fisica, La Habana (Cuba); International Institute for Theoretical and Applied Physics (IITAP), UNESCO and Iowa State University, Ames, IA (United States); Rigol Madrazo, M. [Centro de Estudios Aplicados al Desarrollo Nuclear, La Habana (Cuba)

    2002-03-01

    A recently proposed modified perturbative expansion for QCD incorporating gluon condensation is employed to evaluate the quark and gluon self-energy corrections in first approximation. The results predict mass values of 1/3 of the nucleon mass for the light quarks u, d, and s and a monotonously growing variation with the current mass. The only phenomenological input is that left angle G{sup 2} right angle is evaluated up to order g{sup 2} as a function of the unique parameter C defining the modified propagator, and then C is fixed to give a current estimate of left angle g{sup 2}G{sup 2} right angle. The light quarks u and d as a result are found to be confined and the s, c, b and t ones show damped propagation modes, suggesting a model for the large differences in stability between the nucleons and the higher resonances. The above properties of quark modes diverge from the fully confinement result following from the similar gluon propagator previously considered by Munczek and Nemirovski. On the other hand, the condensate effects on the gluon self-energy furnish a tachyonic mass shell as predicted by the Fukuda analysis of gluon condensation in QCD. (orig.)

  16. Management of the droopy tip: a comparison of three alar cartilage-modifying techniques.

    Science.gov (United States)

    Foda, Hossam M T

    2003-10-01

    The droopy tip is a common nasal deformity in which the tip is inferiorly rotated. Five hundred consecutive rhinoplasty cases were studied to assess the incidence and causes of the droopy tip deformity and to evaluate the role of three alar cartilage-modifying techniques--lateral crural steal, lateral crural overlay, and tongue in groove--in correcting such a deformity. The external rhinoplasty approach was used in all cases. Only one of the three alar cartilage-modifying techniques was used in each case, and the degree of tip rotation and projection was measured both preoperatively and postoperatively. The incidence of droopy tip was 72 percent, and the use of an alar cartilage-modifying technique was required in 85 percent of these cases to achieve the desired degree of rotation. The main causes of droopy tip included inferiorly oriented alar cartilages (85 percent), overdeveloped scrolls of upper lateral cartilages (73 percent), high anterior septal angle (65 percent), and thick skin of the nasal lobule (56 percent). The lateral crural steal technique increased nasal tip rotation and projection, the lateral crural overlay technique increased tip rotation and decreased tip projection, and the tongue-in-groove technique increased tip rotation without significantly changing the amount of projection. The lateral crural overlay technique resulted in the highest degrees of rotation, followed by the lateral crural steal and finally the tongue-in-groove technique. According to these results, the lateral crural steal technique is best indicated in cases with droopy underprojected nasal tip, the lateral crural overlay technique in cases of droopy overprojected nasal tip, and the tongue-in-groove technique in cases where the droopy nasal tip is associated with an adequate amount of projection.

  17. Constipation and Incident CKD.

    Science.gov (United States)

    Sumida, Keiichi; Molnar, Miklos Z; Potukuchi, Praveen K; Thomas, Fridtjof; Lu, Jun Ling; Matsushita, Kunihiro; Yamagata, Kunihiro; Kalantar-Zadeh, Kamyar; Kovesdy, Csaba P

    2017-04-01

    Constipation is one of the most prevalent conditions in primary care settings and increases the risk of cardiovascular disease, potentially through processes mediated by altered gut microbiota. However, little is known about the association of constipation with CKD. In a nationwide cohort of 3,504,732 United States veterans with an eGFR ≥60 ml/min per 1.73 m 2 , we examined the association of constipation status and severity (absent, mild, or moderate/severe), defined using diagnostic codes and laxative use, with incident CKD, incident ESRD, and change in eGFR in Cox models (for time-to-event analyses) and multinomial logistic regression models (for change in eGFR). Among patients, the mean (SD) age was 60.0 (14.1) years old; 93.2% of patients were men, and 24.7% were diabetic. After multivariable adjustments, compared with patients without constipation, patients with constipation had higher incidence rates of CKD (hazard ratio, 1.13; 95% confidence interval [95% CI], 1.11 to 1.14) and ESRD (hazard ratio, 1.09; 95% CI, 1.01 to 1.18) and faster eGFR decline (multinomial odds ratios for eGFR slope constipation associated with an incrementally higher risk for each renal outcome. In conclusion, constipation status and severity associate with higher risk of incident CKD and ESRD and with progressive eGFR decline, independent of known risk factors. Further studies should elucidate the underlying mechanisms. Copyright © 2017 by the American Society of Nephrology.

  18. Cancer incidence among firefighters

    DEFF Research Database (Denmark)

    Pukkala, Eero; Martinsen, Jan Ivar; Weiderpass, Elisabete

    2014-01-01

    .51), adenocarcinoma of the lung (SIR=1.90, 95% CI 1.34 to 2.62), and mesothelioma (SIR=2.59, 95% CI 1.24 to 4.77). By contrast with earlier studies, the incidence of testicular cancer was decreased (SIR=0.51, 95% CI 0.23 to 0.98). CONCLUSIONS: Some of these associations have been observed previously, and potential...

  19. Gaugings at angles from orientifold reductions

    International Nuclear Information System (INIS)

    Roest, Diederik

    2009-01-01

    We consider orientifold reductions to N= 4 gauged supergravity in four dimensions. A special feature of this theory is that different factors of the gauge group can have relative angles with respect to the electro-magnetic SL(2) symmetry. These are crucial for moduli stabilization and de Sitter vacua. We show how such gaugings at angles generically arise in orientifold reductions.

  20. Custom total occlusal convergence angle sticker fabrication.

    Science.gov (United States)

    Cho, Seok-Hwan; Nagy, William W

    2015-09-01

    This article describes a method of fabricating a custom total occlusal convergence angle sticker with photo editing software and label stickers. The custom total occlusal convergence angle sticker can help clinicians achieve an accurate degree of taper during axial wall reduction of tooth preparation. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Practical evaluation of action-angle variables

    International Nuclear Information System (INIS)

    Boozer, A.H.

    1984-02-01

    A practical method is described for establishing action-angle variables for a Hamiltonian system. That is, a given nearly integrable Hamiltonian is divided into an exactly integrable system plus a perturbation in action-angle form. The transformation of variables, which is carried out using a few short trajectory integrations, permits a rapid determination of trajectory properties throughout a phase space volume

  2. Acute angle closure glaucoma following ileostomy surgery

    Directory of Open Access Journals (Sweden)

    Mariana Meirelles Lopes

    2015-02-01

    Full Text Available Angle-closure glaucoma can be induced by drugs that may cause pupillary dilatation. We report a case of a patient that developed bilateral angle closure glaucoma after an ileostomy surgery because of systemic atropine injection. This case report highlights the importance of a fast ophthalmologic evaluation in diseases with ocular involvement in order to make accurate diagnoses and appropriate treatments.

  3. Solid angles III. The role of conformers in solid angle calculations

    CSIR Research Space (South Africa)

    White, D

    1995-06-14

    Full Text Available The values of the solid angles Omega for a range of commonly encountered ligands in organometallic chemistry (phosphines, phosphites, amines, arsines and cyclopentadienyl rings) have been determined. The solid angles were derived from a single...

  4. Cancer incidence among waiters

    DEFF Research Database (Denmark)

    Reijula, Jere; Kjaerheim, Kristina; Lynge, Elsebeth

    2015-01-01

    AIMS: To study cancer risk patterns among waiters in the Nordic countries. METHODS: We identified a cohort of 16,134 male and 81,838 female waiters from Denmark, Finland, Iceland, Norway and Sweden. During the follow-up period from 1961 to 2005, we found that 19,388 incident cancer cases were...... diagnosed. Standardised incidence ratio (SIR) was defined as the observed number of cancer cases divided by the expected number, based on national age, time period and gender-specific cancer incidence rates in the general population. RESULTS: The SIR of all cancers in waiters, in the five countries combined......, was 1.46 (95% CI 1.41-1.51) in men and 1.09 (1.07-1.11) in women. In male waiters, the SIR decreased from 1.79 (1.63-1.96) in 1961-1975, to 1.33 (1.26-1.40) in 1991-2005, but remained stable among women. The SIR among male waiters was highest for cancers in the pharynx (6.11; 95% CI 5.02-7.37), oral...

  5. Contaminated Mexican steel incident

    International Nuclear Information System (INIS)

    1985-01-01

    This report documents the circumstances contributing to the inadvertent melting of cobalt 60 (Co-60) contaminated scrap metal in two Mexican steel foundries and the subsequent distribution of contaminated steel products into the United States. The report addresses mainly those actions taken by US Federal and state agencies to protect the US population from radiation risks associated with the incident. Mexico had much more serious radiation exposure and contamination problems to manage. The United States Government maintained a standing offer to provide technical and medical assistance to the Mexican Government. The report covers the tracing of the source to its origin, response actions to recover radioactive steel in the United States, and return of the contaminated materials to Mexico. The incident resulted in significant radiation exposures within Mexico, but no known significant exposure within the United States. Response to the incident required the combined efforts of the Nuclear Regulatory Commission (NRC), Department of Energy, Department of Transportation, Department of State, and US Customs Service (Department of Treasury) personnel at the Federal level and representatives of all 50 State Radiation Control Programs and, in some instances, local and county government personnel. The response also required a diplomatic interface with the Mexican Government and cooperation of numerous commercial establishments and members of the general public. The report describes the factual information associated with the event and may serve as information for subsequent recommendations and actions by the NRC. 8 figures

  6. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  7. Limited flip angle MR imaging: Hemorrhagic applications

    International Nuclear Information System (INIS)

    Drayer, B.P.; Rigamonti, D.; Johnson, P.C.; Spetzler, R.F.; Keller, P.J.; Flom, R.A.; Bird, C.R.; Hodak, J.A.

    1987-01-01

    The authors studied 64 patients with hemorrhagic brain lesions, including vascular malformations (n = 29), hemorrhagic infarctions (n = 9), chronic slit hemorrhagic residua of hypertensive hematoma (n = 10), trauma (n = 8), and gliobastoma multiforme (n = 8). With a 1.5-T MR imaging system, 5-mm sections were obtained at a repetition time of 300 msec (or 500), an echo time of 12.3 msec (or 10 and 40), and a flip angle of 60 0 (or 20 0 ). The limited flip angle study was always extremely sensitive for the detection of hemosiderin. With multiple cavernous angiomas, additional small lesions (in five of 18 patients) were detected only with the limited flip angle technique. The hemosiderin-laden macrophage residua of hemorrhagic infarction and hypertensive hematoma were better seen on limited flip angle images than on T2-weighted spin-echo images. The detection of blood on limited flip angle images permitted the grading of glioma as glioblastoma multiforme

  8. Experimental study of crossing angle collision

    International Nuclear Information System (INIS)

    Chen, T.; Rice, D.; Rubin, D.; Sagan, D.; Tigner, M.

    1993-05-01

    The non-linear coupling due to the beam-beam interaction with crossing angle has been studied. The major effect of a small (∼12mrad) crossing angle is to excite 5Q x ±Q s =integer coupling resonance family on large amplitude particles, which results in bad lifetime. On the CESR, a small crossing angle (∼2.4mr) was created at the IP and a reasonable beam-beam tune-shift was achieved. The decay rate of the beam is measured as a function of horizontal tune with and without crossing angle. The theoretical analysis, simulation and experimental measurements have a good agreement. The resonance strength as a function of crossing angle is also measured

  9. Experimental study of crossing angle collision

    International Nuclear Information System (INIS)

    Chen, T.; Rice, D.; Rubin, D.; Sagan, D.; Tigner, M.

    1993-01-01

    The non-linear coupling due to the beam-beam interaction with crossing angle has been studied. The major effect of a small (∼12mrad) crossing angle is to excite 5Q x ±Q s =integer coupling resonance family on large amplitude particles, which results in bad lifetime. On the CESR, a small crossing angle (∼2.4mr) was created at the IP and a reasonable beam-beam tune-shift was achieved. The decay rate of the beam is measured as a function of horizontal tune with and without crossing angle. The theoretical analysis, simulation and experimental measurements have a good agreement. The resonance strength as a function of crossing angle is also measured

  10. A Kolsky tension bar technique using a hollow incident tube

    Science.gov (United States)

    Guzman, O.; Frew, D. J.; Chen, W.

    2011-04-01

    Load control of the incident pulse profiles in compression Kolsky bar experiments has been widely used to subject the specimen to optimal testing conditions. Tension Kolsky bars have been used to determine dynamic material behavior since the 1960s with limited capability to shape the loading pulses due to the pulse-generating mechanisms. We developed a modified Kolsky tension bar where a hollow incident tube is used to carry the incident stress waves. The incident tube also acts as a gas gun barrel that houses the striker for impact. The main advantage of this new design is that the striker impacts on an impact cap of the incident tube. Compression pulse shapers can be attached to the impact cap, thus fully utilizing the predictive compression pulse-shaping capability in tension experiments. Using this new testing technique, the dynamic tensile material behavior for Al 6061-T6511 and TRIP 800 (transformation-induced plasticity) steel has been obtained.

  11. A Kolsky tension bar technique using a hollow incident tube

    International Nuclear Information System (INIS)

    Guzman, O; Frew, D J; Chen, W

    2011-01-01

    Load control of the incident pulse profiles in compression Kolsky bar experiments has been widely used to subject the specimen to optimal testing conditions. Tension Kolsky bars have been used to determine dynamic material behavior since the 1960s with limited capability to shape the loading pulses due to the pulse-generating mechanisms. We developed a modified Kolsky tension bar where a hollow incident tube is used to carry the incident stress waves. The incident tube also acts as a gas gun barrel that houses the striker for impact. The main advantage of this new design is that the striker impacts on an impact cap of the incident tube. Compression pulse shapers can be attached to the impact cap, thus fully utilizing the predictive compression pulse-shaping capability in tension experiments. Using this new testing technique, the dynamic tensile material behavior for Al 6061-T6511 and TRIP 800 (transformation-induced plasticity) steel has been obtained

  12. Effect of beet flour on films made from biological macromolecules: Native and modified plantain flour.

    Science.gov (United States)

    Gutiérrez, Tomy J; Guzmán, Romel; Medina Jaramillo, Carolina; Famá, Lucía

    2016-01-01

    Biological macromolecules such as starches of different amylaceous sources have been used in the formulation of edible films. However, there are few studies aimed at evaluating edible and intelligent films with response to pH changes from natural pigments, this despite the importance of these materials. In this context, films from native and modified plantain flour, plasticized with glycerol, with or without the addition of beet flour were developed. The chemical and structural composition of the flours, and its incidence on thickness, water solubility, contact angle, and mechanical and microstructural properties were evaluated, thus as its response to pH changes of the developed films. The observations showed that the incorporation of beet flour allowed to obtain intelligent films front to pH changes alkaline. Likewise, the betalains that were found in beet flour interacted more efficiently with the phosphated plantain flour, limiting well its immediate response to pH changes. In the same way, proteins and sugars of beet flour allowed to obtain more flexible films, due to the hydrogen bond interactions between these constituents and the plantain flours. This latter could justify the decrease of contact angle, and the increase on thickness and solubility of these films. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Validation of aerodynamic parameters at high angles of attack for RAE high incidence research models

    Science.gov (United States)

    Ross, A. Jean; Edwards, Geraldine F.; Klein, Vladislav; Batterson, James G.

    1987-01-01

    Two series of free-flight tests have been conducted for combat aircraft configuration research models in order to investigate flight behavior near departure conditions as well as to obtain response data from which aerodynamic characteristics can be derived. The structure of the mathematical model and values for the mathematical derivatives have been obtained through an analysis of the first series, using stepwise regression. The results thus obtained are the bases of the design of active control laws. Flight test results for a novel configuration are compared with predicted responses.

  14. The quadriceps angle and the incidence of knee injury in Indian ...

    African Journals Online (AJOL)

    South African Journal of Sports Medicine. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 19, No 1 (2007) >. Log in or Register to get access to full text downloads.

  15. Incidence and risk factors of open-angle glaucoma : the Rotterdam study

    NARCIS (Netherlands)

    S. de Voogd (Simone); A. Hofman (Albert)

    2006-01-01

    markdownabstract__Abstract__ Glaucoma is one of the poorest understood and defined eye diseases among those known since our era. Despite two millennia of writing about glaucoma, a straightforward and clear-cut definition is not available worldwide. In essence, glaucoma is an eye disease

  16. Investigating the impact of noise incidence angle on the sound insulation of a supply air window

    DEFF Research Database (Denmark)

    Hansen, Morten B.; Tambo, Torben

    2015-01-01

    The Danish Environmental Agency introduced in 2007 a guideline “Noise from roads”, in which noise limits for open windows were introduced. This guideline has led to investigations of open windows with good sound insulation, and among one of these windows are the “Supply Air Window”. Prior sound i...

  17. The angle of incidence of Paul Roux's catechism - a study on the ...

    African Journals Online (AJOL)

    With the Belijdenis of Paul Roux we have an indigenous document of early eighteenth century theological reflection among some French refugees of the first generations at the Cape. It provides us with useful opportunities to analyse the theology of an important part of the history of the Huguenots. In this study, attention is ...

  18. The quadriceps angle and the incidence of knee injury in indian ...

    African Journals Online (AJOL)

    T Puckree (Bsc Physio, Ms (exercise science), Med, PhD (exercise Physiology))1 a govender (B Physio)2. K govender (B Physio)2. P naidoo (B Physio)2. 1. Department of Physiotherapy, University of KwaZulu-Natal, Durban, and School of Physiotherapy, Sport Science and Optometry, University of KwaZulu-Natal, Westville ...

  19. Ion-damage-free planarization or shallow angle sectioning of solar cells for mapping grain orientation and nanoscale photovoltaic properties.

    Science.gov (United States)

    Kutes, Yasemin; Luria, Justin; Sun, Yu; Moore, Andrew; Aguirre, Brandon A; Cruz-Campa, Jose L; Aindow, Mark; Zubia, David; Huey, Bryan D

    2017-05-05

    Ion beam milling is the most common modern method for preparing specific features for microscopic analysis, even though concomitant ion implantation and amorphization remain persistent challenges, particularly as they often modify materials properties of interest. Atomic force microscopy (AFM), on the other hand, can mechanically mill specific nanoscale regions in plan-view without chemical or high energy ion damage, due to its resolution, directionality, and fine load control. As an example, AFM-nanomilling (AFM-NM) is implemented for top-down planarization of polycrystalline CdTe thin film solar cells, with a resulting decrease in the root mean square (RMS) roughness by an order of magnitude, even better than for a low incidence FIB polished surface. Subsequent AFM-based property maps reveal a substantially stronger contrast, in this case of the short-circuit current or open circuit voltage during light exposure. Electron back scattering diffraction (EBSD) imaging also becomes possible upon AFM-NM, enabling direct correlations between the local materials properties and the polycrystalline microstructure. Smooth shallow-angle cross-sections are demonstrated as well, based on targeted oblique milling. As expected, this reveals a gradual decrease in the average short-circuit current and maximum power as the underlying CdS and electrode layers are approached, but a relatively consistent open-circuit voltage through the diminishing thickness of the CdTe absorber. AFM-based nanomilling is therefore a powerful tool for material characterization, uniquely providing ion-damage free, selective area, planar smoothing or low-angle sectioning of specimens while preserving their functionality. This enables novel, co-located advanced AFM measurements, EBSD analysis, and investigations by related techniques that are otherwise hindered by surface morphology or surface damage.

  20. Ion-damage-free planarization or shallow angle sectioning of solar cells for mapping grain orientation and nanoscale photovoltaic properties

    Science.gov (United States)

    Kutes, Yasemin; Luria, Justin; Sun, Yu; Moore, Andrew; Aguirre, Brandon A.; Cruz-Campa, Jose L.; Aindow, Mark; Zubia, David; Huey, Bryan D.

    2017-05-01

    Ion beam milling is the most common modern method for preparing specific features for microscopic analysis, even though concomitant ion implantation and amorphization remain persistent challenges, particularly as they often modify materials properties of interest. Atomic force microscopy (AFM), on the other hand, can mechanically mill specific nanoscale regions in plan-view without chemical or high energy ion damage, due to its resolution, directionality, and fine load control. As an example, AFM-nanomilling (AFM-NM) is implemented for top-down planarization of polycrystalline CdTe thin film solar cells, with a resulting decrease in the root mean square (RMS) roughness by an order of magnitude, even better than for a low incidence FIB polished surface. Subsequent AFM-based property maps reveal a substantially stronger contrast, in this case of the short-circuit current or open circuit voltage during light exposure. Electron back scattering diffraction (EBSD) imaging also becomes possible upon AFM-NM, enabling direct correlations between the local materials properties and the polycrystalline microstructure. Smooth shallow-angle cross-sections are demonstrated as well, based on targeted oblique milling. As expected, this reveals a gradual decrease in the average short-circuit current and maximum power as the underlying CdS and electrode layers are approached, but a relatively consistent open-circuit voltage through the diminishing thickness of the CdTe absorber. AFM-based nanomilling is therefore a powerful tool for material characterization, uniquely providing ion-damage free, selective area, planar smoothing or low-angle sectioning of specimens while preserving their functionality. This enables novel, co-located advanced AFM measurements, EBSD analysis, and investigations by related techniques that are otherwise hindered by surface morphology or surface damage.

  1. Parallelism measurement of plane glass at oblique incidence by interferometry

    Science.gov (United States)

    Yang, Yi; Zhang, Lin; Shi, Zhendong; Ma, Hua; Ren, Huan; He, Yong

    2018-01-01

    Parallelism is an important parameter of plane glass in high power solid-stat lasers. In this paper, a method for parallelism measurement is proposed. This method is based on total least squares(TLS) to fit wavefront into plane, the parallelism can be calculated by the included angle between planes. Furthermore, with tri-dimensional ray-tracing method, larger aperture plane glass can be measured with smaller interferometer at oblique incidence. A comparison test about parallelism measured at 0° and oblique incidence is set up to verify the accuracy of this method.

  2. Medication incidents reported to an online incident reporting system.

    LENUS (Irish Health Repository)

    Alrwisan, Adel

    2011-01-15

    AIMS: Approximately 20% of deaths from adverse events are related to medication incidents, costing the NHS an additional £500 million annually. Less than 5% of adverse events are reported. This study aims to assess the reporting rate of medication incidents in NHS facilities in the north east of Scotland, and to describe the types and outcomes of reported incidents among different services. Furthermore, we wished to quantify the proportion of reported incidents according to the reporters\\' profession. METHODS: A retrospective description was made of medication incidents reported to an online reporting system (DATIX) over a 46-month-period (July 2005 to April 2009). Reports originated from acute and community hospitals, mental health, and primary care facilities. RESULTS: Over the study period there were 2,666 incidents reported with a mean monthly reporting rate of 78.2\\/month (SD±16.9). 6.1% of all incidents resulted in harm, with insulin being the most commonly implicated medication. Nearly three-quarters (74.2%, n=1,978) of total incidents originated from acute hospitals. Administration incidents were implicated in the majority of the reported medication incidents (59%), followed by prescribing (10.8%) and dispensing (9.9%), while the nondescript "other medication incidents" accounted for 20.3% of total incidents. The majority of reports were made by nursing and midwifery staff (80%), with medical and dental professionals reporting the lowest number of incidents (n=56, 2%). CONCLUSIONS: The majority of medication incidents in this study were reported by nursing and midwifery staff, and were due to administration incidents. There is a clear need to elucidate the reasons for the limited contribution of the medical and dental professionals to reporting medication incidents.

  3. An angled nano-tunnel fabricated on poly(methyl methacrylate) by a focused ion beam

    International Nuclear Information System (INIS)

    Her, Eun Kyu; Chung, Hee-Suk; Oh, Kyu Hwan; Moon, Myoung-Woon

    2009-01-01

    Angled nano-scale tunnels with high aspect ratio were fabricated on poly(methyl methacrylate) (PMMA) using a focused ion beam (FIB). The fabrication parameters such as ion fluence, incidence angle, and acceleration voltage of the Ga + ion beam were first studied on the PMMA surface to explore the formation of the nano-scale configurations such as nano-holes and cones with diameter in the range of 50-150 nm at an ion beam acceleration voltage of 5-20 kV. It was also found that the PMMA surface exposed to FIB was changed into an amorphous graphitic structure. Angled nano-scale tunnels were fabricated with high aspect ratio of 700-1500 nm in depth and 60 nm in mean diameter at an ion beam acceleration voltage of 5 kV and under a specific ion beam current. The angle of the nano-tunnels was found to follow the incident angle of the ion beam tilted from 0 0 to 85 0 , which has the potential for creating a mold for anisotropic adhesives by mimicking the hairs on a gecko's feet.

  4. Incident users of antipsychotics

    DEFF Research Database (Denmark)

    Baandrup, Lone; Kruse, Marie

    2016-01-01

    PURPOSE: In Denmark, as well as in many other countries, consumption of antipsychotics is on the rise, partly due to increasing off-label use. The aim of this study was to analyze and quantify the extent of off-label use and polypharmacy in incident users of antipsychotic medication, and to examine...... initial antipsychotic prescribing patterns and associated use of mental health care services. METHOD: Population-based cohort study linking the following Danish national registers: the Central Psychiatric Research Register, the Register of Medicinal Product Statistics, and Statistics Denmark. RESULTS...

  5. Incidence of pneumonia and gastroenteritis among infants admitted ...

    African Journals Online (AJOL)

    and aggregated nature of the HMIS databases. The objective of this study was to document the incidence of infant morbidity and mortality from pneumonia and gastroenteritis among infants in a referral hospital setting in order to determine modifiable risk factors that could guide policy and management guidelines. Methods.

  6. Variable angle spectroscopic ellipsometric characterization of HfO2 thin film

    Science.gov (United States)

    Kumar, M.; Kumari, N.; Karar, V.; Sharma, A. L.

    2018-02-01

    Hafnium Oxide film was deposited on BK7 glass substrate using reactive oxygenated E-Beam deposition technique. The film was deposited using in-situ quartz crystal thickness monitoring to control the film thickness and rate of evaporation. The thin film was grown with a rate of deposition of 0.3 nm/s. The coated substrate was optically characterized using spectrophotometer to determine its transmission spectra. The optical constants as well as film thickness of the hafnia film were extracted by variable angle spectroscopic ellipsometry with Cauchy fitting at incidence angles of 65˚, 70˚ and 75˚.

  7. Improving freight crash incident management.

    Science.gov (United States)

    2015-06-01

    The objective of this study was to determine the most effective way to mitigate the effect of freight : crash incidents on Louisiana freeways. Candidate incident management strategies were reviewed from : practice in other states and from those publi...

  8. Common Causes of Pesticide Incidents

    Science.gov (United States)

    There are many types of pesticide incidents. EPA staff analyze pesticide incident reports involving people (including children and farm workers), pets, domestic animals, wildlife including bees and other pollinators, and the environment.

  9. Patellar angle in Osgood-Schlatter disease.

    Science.gov (United States)

    Sen, R K; Sharma, L R; Thakur, S R; Lakhanpal, V P

    1989-02-01

    A new patellar angle is described in lateral radiographs of the knee joint. One line is drawn along the articular surface of the patella and another from the end of the inferior articular cartilage to the patellar apex. The angle formed by these two lines averaged 33 degrees in 68 knees joints afflicted with Osgood-Schlatter disease and 47 degrees in 71 age-matched controls and 198 adult controls. The small angle in Osgood-Schlatter disease is proposed to be an important factor in the pathogenesis of the traction apophysitis.

  10. Small-angle scattering on soft materials

    International Nuclear Information System (INIS)

    Mortensen, K.

    1994-01-01

    Small angle x-ray and neutron scattering provides tools for investigation of structures on the length scale 10 to 1000 A. This is the length scale which is relevant for many topics within soft materials, like biological macromolecules, polymers, colloids, etc. The very large difference between the scattering amplitude of neutrons by regular hydrogen and deuterium makes neutron scattering a very important technique within soft condensed matter. The basic theory for small angle scattering is reviewed. Experimental results obtained by small angle scattering are shown, with emphasis on soft materials. (author). 33 refs, 6 figs, 1 tab

  11. Computing angle of arrival of radio signals

    Science.gov (United States)

    Borchardt, John J.; Steele, David K.

    2017-11-07

    Various technologies pertaining to computing angle of arrival of radio signals are described. A system that is configured for computing the angle of arrival of a radio signal includes a cylindrical sheath wrapped around a cylindrical object, where the cylindrical sheath acts as a ground plane. The system further includes a plurality of antennas that are positioned about an exterior surface of the cylindrical sheath, and receivers respectively coupled to the antennas. The receivers output measurements pertaining to the radio signal. A processing circuit receives the measurements and computes the angle of arrival of the radio signal based upon the measurements.

  12. Risk factors for first time incidence sciatica: a systematic review.

    Science.gov (United States)

    Cook, Chad E; Taylor, Jeffrey; Wright, Alexis; Milosavljevic, Steven; Goode, Adam; Whitford, Maureen

    2014-06-01

    Characteristically, sciatica involves radiating leg pain that follows a dermatomal pattern along the distribution of the sciatic nerve. To our knowledge, there are no studies that have investigated risk factors associated with first time incidence sciatica. The purpose of the systematic review was to identify the longitudinal risk factors associated with first time incidence sciatica and to report incidence rates for the condition. For the purposes of this review, first time incidence sciatica was defined as either of the following: 1) no prior history of sciatica or 2) transition from a pain-free state to sciatica. Studies included subjects of any age from longitudinal, observational, cohort designs. The study was a systematic review. Eight of the 239 articles identified by electronic search strategies met the inclusion criteria. Risk factors and their respective effect estimates were reported using descriptive analysis and the preferred reporting items for systematic reviews and meta-analyses guidelines. Modifiable risk factors included smoking, obesity, occupational factors and health status. Non-modifiable factors included age, gender and social class. Incidence rates varied among the included studies, in part reflecting the variability in the operationalized definition of sciatica but ranged from sciatica are modifiable, suggesting the potential benefits of primary prevention. In addition, those risk factors are also associated with unhealthy lifestyles, which may function concomitantly toward the development of sciatica. Sciatica as a diagnosis is inconsistently defined among studies. © 2013 John Wiley & Sons, Ltd.

  13. Laser-induced breakdown spectra of rock powders at variable ablation and collection angles under Mars-analog conditions

    Science.gov (United States)

    Breves, E. A.; Lepore, K.; Dyar, M. D.; Bender, S. C.; Tokar, R. L.; Boucher, T.

    2017-11-01

    Laser-induced breakdown spectroscopy has become a popular tool for rapid elemental analysis of geological materials. However, quantitative applications of LIBS are plagued by variability in collected spectra that cannot be attributed to differences in geochemical composition. Even under ideal laboratory conditions, variability in LIBS spectra creates a host of difficulties for quantitative analysis. This is only exacerbated during field work, when both the laser-sample distance and the angle of ablation/collection are constantly changing. A primary goal of this study is to use empirical evidence to provide a more accurate assessment of uncertainty in LIBS-derived element predictions. We hope to provide practical guidance regarding the angles of ablation and collection that can be tolerated without substantially increasing prediction uncertainty beyond that which already exists under ideal laboratory conditions. Spectra were collected from ten geochemically diverse samples at angles of ablation and collection ranging from 0° to ± 60°. Ablation and collection angles were changed independently and simultaneously in order to isolate spectral changes caused by differences in ablation angle from those due to differences in collection angle. Most of the variability in atomic and continuum spectra is attributed to changes in the ablation angle, rather than the collection angle. At higher angles, the irradiance of the laser beam is lower and produces smaller, possibly less dense plasmas. Simultaneous changes in the collection angle do not appear to affect the collected spectra, possibly because smaller plasmas are still within the viewing area of the collection optics, even though this area is reduced at higher collection angles. A key observation is that changes in the magnitude of atomic and total emission are team is using lab data acquired under normal incidence and collection angles to predict the compositions of Mars targets at varying angles. Thus, the increased

  14. Increasing incidence of pyogenic spondylodiscitis

    DEFF Research Database (Denmark)

    Kehrer, Michala; Pedersen, Court; Jensen, Thøger G

    2014-01-01

    Smaller studies indicate that the incidence of pyogenic spondylodiscitis is increasing, possible related to a growing elderly population. Data supporting this is sparse, and we therefore studied patient characteristics and changes in spondylodiscitis incidence 1995-2008.......Smaller studies indicate that the incidence of pyogenic spondylodiscitis is increasing, possible related to a growing elderly population. Data supporting this is sparse, and we therefore studied patient characteristics and changes in spondylodiscitis incidence 1995-2008....

  15. Incident Management: Process into Practice

    Science.gov (United States)

    Isaac, Gayle; Moore, Brian

    2011-01-01

    Tornados, shootings, fires--these are emergencies that require fast action by school district personnel, but they are not the only incidents that require risk management. The authors have introduced the National Incident Management System (NIMS) and the Incident Command System (ICS) and assured that these systems can help educators plan for and…

  16. Small angle neutron scattering experiment and raw data reduction

    International Nuclear Information System (INIS)

    Wei Guohai; Li Tianfu; Zhang Li; Wang Yu; Wang Hongli; Liu Xiangfeng

    2010-01-01

    Small angle neutron scattering (SANS) technique is a powerful tool for nanometer structural analysis of materials. The process of SANS measurement, and the raw data reduction, is relatively complicated. In order to obtain the absolute SANS intensity, one needs to measure intensities of the incident and scattered beams, the sample transmission, the background, the scattering and transmission of the empty cell etc. If a wide scattering vector range is needed, one has to measure the same sample under different instrument configurations. Also, a large number of data treatments are needed before one obtains the SANS data for further analysis. In this paper, after a short introduction to the SANS basic theory and the experimental system, we focus on the raw data reduction method, in which the averaging and the combination of the isotropically scattered data are discussed in detail. (authors)

  17. Angles-Only Navigation System for Nanosatellites

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the proposed work is to develop and implement an angles-only relative navigation system on hardware suitable for deployment on nanosatellites or...

  18. Directional Wide-Angle Range Finder (DWARF)

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation, the Directional Wide-Angle Range Finder (DWARF) is the creation of a laser range-finder with a wide field-of-view (FOV) and a directional...

  19. Low angle X-ray scattering

    International Nuclear Information System (INIS)

    Torrianni, I.L.

    1983-01-01

    The theoretical and experimental problems appearing in diffraction experiments at very low angles by several kinds of materials are discussed. The importance of synchrotron radiation in such problems is shown. (L.C.) [pt

  20. Leflunomide for the treatment of rheumatoid arthritis in clinical practice: Incidence and severity of hepatotoxicity

    NARCIS (Netherlands)

    Van Roon, Eric N.; Jansen, Tim L.Th.A.; Houtman, Nella M.; Spoelstra, Piet; Brouwers, Jacobus R.B.J.

    2004-01-01

    Objective: Leflunomide is a novel disease modifying antirheumatic drug (DMARD). Because of reports on possible hepatotoxicity and adaptations in the recommendations for monitoring liver function during leflunomide treatment, we conducted a study to evaluate the incidence and severity of

  1. Small-angle X-ray scattering (SAXS) studies of the structure of mesoporous silicas

    Science.gov (United States)

    Zienkiewicz-Strzałka, M.; Skibińska, M.; Pikus, S.

    2017-11-01

    Mesoporous ordered silica nanostructures show strong interaction with X-ray radiation in the range of small-angles. Small-angle X-ray scattering (SAXS) measurements based on the elastically scattered X-rays are important in analysis of condensed matter. In the case of mesoporous silica materials SAXS technique provides information on the distribution of electron density in the mesoporous material, in particular describing their structure and size of the unit cell as well as type of ordered structure and finally their parameters. The characterization of nanopowder materials, nanocomposites and porous materials by Small-Angle X-ray Scattering seems to be valuable and useful. In presented work, the SAXS investigation of structures from the group of mesoporous ordered silicates was performed. This work has an objective to prepare functional materials modified by noble metal ions and nanoparticles and using the small-angle X-ray scattering to illustrate their properties. We report the new procedure for describing mesoporous materials belonging to SBA-15 and MCM-41 family modified by platinum, palladium and silver nanoparticles, based on detailed analysis of characteristic peaks in the small-angle range of X-ray scattering. This procedure allows to obtained the most useful parameters for mesoporous materials characterization and their successfully compare with experimental measurements reducing the time and material consumption with good precision for particles and pores with a size below 10 nm.

  2. Small-angle neutron-scattering experiments

    International Nuclear Information System (INIS)

    Hardy, A.D.; Thomas, M.W.; Rouse, K.D.

    1981-04-01

    A brief introduction to the technique of small-angle neutron scattering is given. The layout and operation of the small-angle scattering spectrometer, mounted on the AERE PLUTO reactor, is also described. Results obtained using the spectrometer are presented for three materials (doped uranium dioxide, Magnox cladding and nitrided steel) of interest to Springfields Nuclear Power Development Laboratories. The results obtained are discussed in relation to other known data for these materials. (author)

  3. Axial vector mass spectrum and mixing angles

    International Nuclear Information System (INIS)

    Caffarelli, R.V.; Kang, K.

    1976-01-01

    Spectral sum rules of the axial-vector current and axial-vector current-pseudoscalar field are used to study the axial-vector mass spectrum and mixing angles, as well as the decay constants and mixing angles of the pseudoscalar mesons. In general, the result is quite persuasive for the existence of the Jsup(PC) = 1 ++ multiplet in which one has a canonical D-E mixing. (Auth.)

  4. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes.

    Science.gov (United States)

    Schreurs, Mervin J; Benjaminse, Anne; Lemmink, Koen A P M

    2017-10-03

    Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. 13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4×2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α≤0.05a priori. At all cutting angles, males showed greater knee flexion angles than females (pknee flexion -42.53°±8.95°, females decreased their knee flexion angle from -40.6°±7.2° when cutting at 45° to -36.81°±9.10° when cutting at 90°, 135° and 180° (pKnee flexion moment decreased for both sexes when cutting towards sharper angles (pknee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (pknee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Energy and zenith angle dependence of atmospheric muons

    CERN Document Server

    Maeda, K

    1973-01-01

    The recently proposed new process for energetic-muon production in the atmosphere should be tested at Mt. Chacaltaya. Rigorous calculations of zenith-angle distribution of atmospheric muons have been made for the altitude of 5200 m above sea level with energy range from 100 GeV to 100 TeV and for zenith angles from 0 degrees to 92.3 degrees . Calculations are based on the extension of the Chapman function to the case of a non-isothermal atmosphere, taking into account (i) energy- dependent nuclear-interaction mean free path of cosmic-ray hadrons in air, (ii) different magnitudes of photonuclear cross-section in the energy-loss process of muons in the atmosphere, (iii) contributions of atmospheric muons arriving below the horizontal directions, and (iv) atmospheric structure and geomagnetic deflection. Results are compared with those corresponding to sea level. Range straggling, particularly its effect on horizontally incident muons, is investigated by Monte Carlo calculation, indicating that its effects and t...

  6. Grazing incidence beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.

    1985-01-01

    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  7. Nonlinear angle control of a sectioned airfoil by using shape memory alloys

    Directory of Open Access Journals (Sweden)

    Abreu G.

    2014-01-01

    Full Text Available The present work illustrates an application of shape memory alloys and nonlinear controller applied to the active angular control of a sectioned airfoil. The main objective of the proposed control system is to modify the shape of the profile based on a reference angle. The change of the sectioned airfoil angle is resultant by the effect of shape memory of the alloy due to heating of the wire caused by an electric current that changes its temperature by Joule effect. Considering the presence of plant’s nonlinear effects, especially in the mathematical model of the alloy, this work proposes the application of an on-off control system.

  8. Slow manifold and Hannay angle in the spinning top

    Energy Technology Data Exchange (ETDEWEB)

    Berry, M V [H H Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Shukla, P [Department of Physics, Indian Institute of Technology, Kharagpur (India)

    2011-01-15

    The spin of a top can be regarded as a fast variable, coupled to the motion of the axis which is slow. In pure precession, the rotation of the axis round a cone (without nutation), can be considered as the result of a reaction from the fast spin. The resulting restriction of the total state space of the top is an illustrative example, at graduate-student level, of the general dynamical concept of the slow manifold. For this case, the slow manifold can be calculated exactly, and expanded as a series of reaction forces (of magnetic type) in powers of slowness, corresponding to a modified precession frequency. The forces correspond to a series for the Hannay angle for the fast motion, describing the location of a point on the top.

  9. a modified power law for determinig flow characteristics of fluid

    African Journals Online (AJOL)

    user

    1986-09-01

    Sep 1, 1986 ... CHARACTERISTICS OF FLUID. BY. G. SODAH AYERNOR. Department of Food Science and Technology. University of Nigeria Nsukka. ABSTRACT. A modified power law derived with “angle of deviation flow was used to determine the, rheological properties of corn syrup (CS), honey (H), emulsion salad ...

  10. A Modified Power Law for Determining Flow Characteristics of Fluid ...

    African Journals Online (AJOL)

    A modified power law derived with “angle of deviation flow was used to determine the, rheological properties of corn syrup (CS), honey (H), emulsion salad dressing cream (SC) and mixture of SC and H: CS. The model proved useful in calculating the flow behaviour index (n) and estimating the, critical shear rate ( ). Results ...

  11. Modified rotatory instruments for transphenoidal surgery: technical note.

    Science.gov (United States)

    Marino Júnior, R

    1979-12-01

    A series of modified gyratory bayonets instruments is described. They have the advantage to allow any adjustable position within a 360 degree rotation angle, during the various surgical steps of transphenoidal surgery, thus keeping the surgeon's hand always at the same position.

  12. Modified rotatory instruments for transphenoidal surgery: technical note

    Directory of Open Access Journals (Sweden)

    Raul Marino Jr

    1979-12-01

    Full Text Available A series of modified gyratory bayonets instruments is described. They have the advantage to allow any adjustable position within a 360° rotation angle, during the various surgical steps of transphenoidal surgery, thus keeping the surgeon's hand always at the same position.

  13. A modified sliding spectral method and its application to COSMIC ...

    Indian Academy of Sciences (India)

    In the moist lower troposphere, a limitation of the sliding spectral (SS) method is the restriction of the resolution of bending angle profiles because of the atmospheric multipath effect and noise. A modified sliding spectral (MSS) method is proposed in this paper to improve the inversion resolution of SS method in the moist ...

  14. Experimental fracture toughness characterization using the modified TSD specimen

    DEFF Research Database (Denmark)

    Berggreen, Christian; Quispitupa, Amilcar; Alonso, Jose L.

    2010-01-01

    The modified Tilted Sandwich Debond (TSD) specimen provides an improved methodology for characterization of the face/core fracture resistance. An experimental mixed mode characterization of the fracture toughness spanning a large range of phase angles has been achieved by specific steel bar...

  15. Illumination angle and layer thickness influence on the photo current generation in organic solar cells: A combined simulative and experimental study

    International Nuclear Information System (INIS)

    Mescher, Jan; Mertens, Adrian; Egel, Amos; Kettlitz, Siegfried W.; Colsmann, Alexander; Lemmer, Uli

    2015-01-01

    In most future organic photovoltaic applications, such as fixed roof installations, facade or clothing integration, the solar cells will face the sun under varying angles. By a combined simulative and experimental study, we investigate the mutual interdependencies of the angle of light incidence, the absorber layer thickness and the photon harvesting efficiency within a typical organic photovoltaic device. For thin absorber layers, we find a steady decrease of the effective photocurrent towards increasing angles. For 90-140 nm thick absorber layers, however, we observe an effective photocurrent enhancement, exhibiting a maximum yield at angles of incidence of about 50°. Both effects mainly originate from the angle-dependent spatial broadening of the optical interference pattern inside the solar cell and a shift of the absorption maximum away from the metal electrode

  16. Comparative biometric study between plateau iris configuration and primary open angle glaucoma with narrow angle.

    Science.gov (United States)

    Diniz Filho, Alberto; Cronemberger, Sebastião; Mérula, Rafael Vidal; Calixto, Nassim

    2009-01-01

    To investigate biometrically the differences between plateau iris configuration (PIC) eyes and primary open angle glaucoma with narrow angle eyes. A comparative study involving a case series with 20 eyes of 11 plateau iris configuration patients and 45 eyes of 27 primary open angle glaucoma with narrow angle eyes patients was done. The following measurements were taken: corneal curvature, central corneal thickness, anterior chamber depth, lens thickness (LT), axial length (AL), lens thickness and axial length ratio, lens position (LP) and relative lens position (RLP). The plateau iris configuration eyes presented a higher corneal cuvature value than primary open angle glaucoma with narrow angle eyes eyes but not with clinical and statistical difference (P=0.090). The plateau iris configuration eyes demonstrated a higher central corneal thickness, with statistical significance, when compared to primary open angle glaucoma with narrow angle eyes (P=0.010). Statistical significant difference between plateau iris configuration and primary open angle glaucoma with narrow angle eyes was found in axial length (21.69 +/- 0.98 vs. 22.42 +/- 0.89; P=0.003). No significant difference was found when anterior chamber depth (2.62 +/- 0.23 vs. 2.71 +/- 0.31; P=0.078), LT (4.67 +/- 0.36 vs. 4.69 +/- 0.45; P=0.975), LT/AL (2.16 +/- 0.17 vs. 2.10 +/- 0.21; P=0.569), LP (4.95 +/- 0.25 vs. 5.06 +/- 0.34; P=0.164) and RLP (0.23 +/- 0.01 vs. 0.22 +/- 0.14; P=0.348) were evaluated. The eyes with plateau iris configuration presented statistical significantly shorter axial length and higher central corneal thickness than primary open angle glaucoma with narrow angle eyes.

  17. Fractal approach in petrology: Combining ultra small angle (USANS), and small angle neutron scattering (SANS)

    International Nuclear Information System (INIS)

    Lo Celso, F.; Triolo, R.; Triolo, F.; Triolo, A.; Lin, J.S.; Lucido, G.

    2000-01-01

    Ultra small angle neutron scattering instruments have recently covered the gap between the size resolution available with conventional intermediate angle neutron scattering and small angle neutron scattering instruments on one side and optical microscopy on the other side. Rocks showing fractal behavior in over two decades of momentum transfer and seven orders of magnitude of intensity are examined and fractal parameters are extracted from the combined USANS and SANS curves

  18. Fractal Approach in Petrology: Combining Ultra-Small Angle (USANS) and Small Angle Neutron Scattering (SANS)

    International Nuclear Information System (INIS)

    LoCelso, F.; Triolo, F.; Triolo, A.; Lin, J.S.; Lucido, G.; Triolo, R.

    1999-01-01

    Ultra small angle neutron scattering instruments have recently covered the gap between the size resolution available with conventional intermediate angle neutron scattering and small angle neutron scattering instruments on one side and optical microscopy on the other side. Rocks showing fractal behavior in over two decades of momentum transfer and seven orders of magnitude of intensity are examined and fractal parameters are extracted from the combined USANS and SANS curves

  19. Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

    Science.gov (United States)

    Fang, Ning; Sun, Wei

    2015-04-21

    A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

  20. Monsoon and primary acute angle closure in malaysia.

    Science.gov (United States)

    Ch'ng, T W; Mosavi, S A A; Noor Azimah, A A; Azlan, N Z; Azhany, Y; Liza-Sharmini, A T

    2013-10-01

    Acute angle closure (AAC) without prompt treatment may lead to optic neuropathy. Environmental factor such as climate change may precipitate pupillary block, the possible mechanism of AAC. To determine the association of northeast monsoon and incidence of AAC in Malaysia. A retrospective study was conducted on AAC patients admitted to two main tertiary hospitals in Kelantan, Malaysia between January 2001 and December 2011. The cumulative number of rainy day, amount of rain, mean cloud cover and 24 hours mean humidity at the estimated day of attack were obtained from the Department of Meteorology, Malaysia. A total 73 cases of AAC were admitted with mean duration of 4.1SD 2.0 days. More than half have previous history of possibility of AAC. There was higher incidence of AAC during the northeast monsoon (October to March). There was also significant correlation of number of rainy day (r=0.718, pclimate as the potential risk factor. Prompt treatment to arrest pupillary block and reduction of the intraocular pressure is important to prevent potential glaucomatous damage. Public awareness of AAC and accessibility to treatment should be part of preparation to face the effect of northeast monsoon.

  1. Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS

    Science.gov (United States)

    Fang, Houfei; Huang, John; Thomson, Mark W.

    2009-01-01

    An effort to develop large-aperture, wide-angle-scanning reflectarray antennas for microwave radar and communication systems is underway. In an antenna of this type as envisioned, scanning of the radiated or incident microwave beam would be effected through mechanical rotation of the passive (reflective) patch antenna elements, using microelectromechanical systems (MEMS) stepping rotary actuators typified by piezoelectric micromotors. It is anticipated that the cost, mass, and complexity of such an antenna would be less than, and the reliability greater than, those of an electronically scanned phased-array antenna of comparable beam-scanning capability and angular resolution. In the design and operation of a reflectarray, one seeks to position and orient an array of passive patch elements in a geometric pattern such that, through constructive interference of the reflections from them, they collectively act as an efficient single reflector of radio waves within a desired frequency band. Typically, the patches lie in a common plane and radiation is incident upon them from a feed horn.

  2. Small-angle neutron scattering instrumentation at the Australian replacement research reactor

    International Nuclear Information System (INIS)

    Gilbert, E.

    2003-01-01

    Full text: A small-angle neutron scattering instrument is being designed as part of the initial instrument suite for the 20 MW Australian Replacement Research Reactor. The proposed 40 m long instrument will receive neutrons from a large liquid-D 2 cold source, use a 1 m 2 detector, have incident beam polarisation and will have provision for polarisation analysis. Scheduled for completion in January 2006, the conceptual details of the new SANS instrument are presented

  3. Collimation effects in small-angle X-ray and neutron scattering

    International Nuclear Information System (INIS)

    Schmidt, P.W.

    1988-01-01

    To obtain adequate intensity in small-angle X-ray and neutron scattering measurements, the apertures that define the incident and scattered beams often must be made so large that the measured intensity is an average over an appreciable interval of scattering angles. Allowance must frequently be made for the resulting distortion of the measured scattering curve. A technique previously developed by Hendricks and Schmidt for describing collimation effects is outlined. This method makes use of a function called the ''weighting function'', which specifies the width of the interval over which the intensity is averaged and indicates the emphasis given to scattering angles within this interval. A new calculation of the weighting function for pinhole collimating systems, which employ circularly symmetric apertures instead of long narrow slits, is presented. Several techniques for performing collimation corrections are described, and a review is given of results that several workers have recently obtained in studies of collimation effects in pinhole systems. (orig.)

  4. High temperature furnaces for small and large angle neutron scattering of disordered materials

    International Nuclear Information System (INIS)

    Bletry, J.; Taverniere, P.; Senillou, C.; Desre, P.; Maret, M.; Chieux, P.

    1984-01-01

    Two similar high temperature furnaces (up to 2000 0 C) have been developed for large angle and small angle neutron scattering (SANS) experiments respectively. They are vacuum furnaces with a thin tungsten foil heating element supplied by two tantalum leads, and shielded by thin tungsten foils maintained in a tantalum box. In a neutron beam, the furnaces produce a very low scattering level (without any Bragg peaks) due to the openings in the heating element, the shields and the tantalum box for the incident, unscattered beam and the scattered beam at low angles. Thus the furnace absorption correction is also much easier. A platinum thermocouple controls temperature, very high temperatures are measured optically. A vacuum chamber has been especially designed for SANS experiments with two windows in polished sapphire. The furnaces have been successfully used for the study of liquid alloys on the D4, D11 and D17 spectrometers at the ILL

  5. Modified sol-gel coatings for biotechnological applications

    Energy Technology Data Exchange (ETDEWEB)

    Beganskiene, A [Department of General and Inorganic Chemistry, Vilnius University, Vilnius LT-03225 (Lithuania); Raudonis, R [Department of General and Inorganic Chemistry, Vilnius University, Vilnius LT-03225 (Lithuania); Jokhadar, S Zemljic [Faculty of Medicine, Institute of Biophysics, Lipiceva 2, Ljubljana SI-1000 (Slovenia); Batista, U [Faculty of Medicine, Institute of Biophysics, Lipiceva 2, Ljubljana SI-1000 (Slovenia); Kareiva, A [Department of General and Inorganic Chemistry, Vilnius University, Vilnius LT-03225 (Lithuania)

    2007-12-15

    The modified sol-gel derived silica coatings were prepared and characterized. The amino and methyl groups were introduced onto the colloidal silica. The silica coatings with different wettability properties: coloidal silica (water contact angle 17 deg.), polysiloxane (61 deg.), methyl-modified (158 deg. and 46 deg.) coatings samples were tested for CaCo-2 cells proliferation. Methyl-modified coating (46 deg.) proved to be the best substrate for cell proliferation. CaCo-2 cell proliferation two days post seeding was significantly faster on almost laminine, fibronectin and collagen-1 coated samples compared to corresponding controls.

  6. Pre-Launch JPSS-2 VIIRS Response versus Scan Angle Characterization

    Directory of Open Access Journals (Sweden)

    Jeff McIntire

    2017-12-01

    Full Text Available On-orbit whisk-broom sensors have scanning mirror assemblies, whose reflectance variations with scan angle must be characterized prior to launch. One such instrument is the Visible Infrared Imaging Radiometer Suite (VIIRS onboard the Joint Polar Satellite System 2 (JPSS-2 platform. The scanning optics inside VIIRS includes a four mirror rotating telescope assembly (RTA and a half angle mirror (HAM, rotating at half the speed of the RTA, which de-rotates the light before it enters the aft-optics assembly. The angle of incidence (AOI on the HAM varies with scan angle; all of the other optical components in VIIRS have a fixed AOI with scan angle. In general, the reflectance of the HAM will vary with AOI. This parameter is difficult to quantify once in orbit and therefore must be characterized pre-launch. Ground measurements were performed in the summer of 2016 to determine the relative reflectance change of the instrument with scan angle, referred to as the response versus scan angle (RVS. This work will describe the RVS testing performed and the results obtained, including an atmospheric water vapor correction and an uncertainty analysis. Results indicate that the reflectance variation with scan angle is small for spectral bands between 0.4 μ m and 4 μ m (less than 2% over the full range of AOI; in contrast, the reflectance variation is between 3% and 10% for the spectral bands in the 8 μ m to 12 μ m range. Uncertainties are below 0.05% in the reflective solar spectral region and below 0.26% in the thermal emissive spectral region. Comparisons to previous VIIRS builds (on the SNPP and JPSS-1 satellites show comparable performance.

  7. Graphene spin valve: An angle sensor

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Zahir, E-mail: zahir.upc@gmail.com [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Hussain, Ghulam [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi 23640, Khyber Pakhtunkhwa (Pakistan); Siddique, Salma [Department of Bioscience & Biotechnology, Sejong University, Seoul 143-747 (Korea, Republic of); Iqbal, Muhammad Waqas [Department of Physics, Riphah Institute of Computing and Applied Sciences (RICAS), Riphah International University, Lahore (Pakistan)

    2017-06-15

    Graphene spin valves can be optimized for various spintronic applications by tuning the associated experimental parameters. In this work, we report the angle dependent magnetoresistance (MR) in graphene spin valve for different orientations of applied magnetic field (B). The switching points of spin valve signals show a clear shift towards higher B for each increasing angle of the applied field, thus sensing the response for respective orientation of the magnetic field. The angular variation of B shifts the switching points from ±95 G to ±925 G as the angle is varied from 0° to 90° at 300 K. The observed shifts in switching points become more pronounced (±165 G to ±1450 G) at 4.2 K for similar orientation. A monotonic increase in MR ratio is observed as the angle of magnetic field is varied in the vertical direction at 300 K and 4.2 K temperatures. This variation of B (from 0° to 90°) increases the magnitude of MR ratio from ∼0.08% to ∼0.14% at 300 K, while at 4.2 K it progresses to ∼0.39% from ∼0.14%. The sensitivity related to angular variation of such spin valve structure can be employed for angle sensing applications.

  8. A Viewpoint on the Quantity "Plane Angle"

    Science.gov (United States)

    Eder, W. E.

    1982-01-01

    Properties of the quantity "plane angle" are explored under the hypothesis that it is a dimensional quantity. The exploration proceeds especially with respect to the physical concept, its mathematical treatment, vector concepts, measurement theory, units of related quantities, engineering pragmatism, and SI. An attempt is made to bring these different relations into a rational, logical and consistent framework, and thus to justify the hypothesis. Various types of vectorial quantities are recognized, and their properties described with an outline of the necessary algebraic manipulations. The concept of plane angle is amplified, and its interdependence with the circular arc is explored. The resulting units of plane angle form a class of similar scales of measurement. Consequences of the confirmed hypothesis are developed for mathematical expressions involving trigonometric functions, rotational volumes and areas, mathematical limits, differentiation and series expansion. Consequences for mechanical rotational quantities are developed, with proposals for revisions to a number of expressions for derived units within SI. A revised definition for the quantity "plane angle" is stated to take account of the developed insights. There is a clear need to reconsider the status of plane angle and some other quantities within the international framework of SI.

  9. PRIMARY OPEN ANGLE GLAUCOMA IN THYROID DISORDER

    Directory of Open Access Journals (Sweden)

    Pragati Garg

    2016-07-01

    Full Text Available PURPOSE To assess the association of thyroid profile with open angle glaucoma. DESIGN Cross-sectional observational study. MATERIAL AND METHOD 128 cases of diagnosed thyroid disorder were enrolled. 5 cases dropped out. Ocular examination included applanation tonometry, stereoscopic optic disc photography, and automated perimetry. Correlative association of thyroid disorder and open angle glaucoma was assessed. RESULTS Of 123 patients of thyroid disorder, 87.8% had hypothyroidism and remaining 12.2% had hyperthyroidism. 15.74% of hypothyroidism and 20% of hyperthyroidism patients had open angle glaucoma, which was statistically significant (Pearson chi-square: Value=6.548, df=2, p=0.040. On multivariate analysis with other risk factors like female sex, family history of glaucoma, myopia, hypertension, and diabetes; it was found that hypothyroidism is an independent risk factor for open angle glaucoma. CONCLUSION All patients having thyroid disorder should be investigated for early diagnosis of open angle glaucoma so that if need be antiglaucoma treatment is started at the earliest and the eye maybe saved from any further deterioration.

  10. On Modified Bar recursion

    DEFF Research Database (Denmark)

    Oliva, Paulo Borges

    2002-01-01

    Modified bar recursion is a variant of Spector's bar recursion which can be used to give a realizability interpretation of the classical axiom of dependent choice. This realizability allows for the extraction of witnesses from proofs of forall-exists-formulas in classical analysis. In this talk I...... shall report on results regarding the relationship between modified and Spector's bar recursion. I shall also show that a seemingly weak form of modified bar recursion is as strong as "full" modified bar recursion in higher types....

  11. Potential application of a homogeneous and anisotropic slab as an angle insensitive absorbing material

    Directory of Open Access Journals (Sweden)

    Fang Wang

    2017-06-01

    Full Text Available In this paper, a flat and incident angle independence absorbing material is proposed and numerically verified in the optical spectrum. A homogeneous and anisotropic dielectric slab as a non-reflecting layer is first reviewed, and a feasible realization strategy of the slab is then given by using layered isotropic materials. When the loss components of the constitutive materials are not zero, the slab will work as an angle insensitive absorbing layer, and the absorption rate augments with increase of the losses. As the numerical verifications, the field distributions of a metallic cylinder and a triangular metallic object individually covered by the designed absorbing layer are demonstrated. The simulation results show that the designed absorbing layer can efficiently absorb the incident waves with the property of incident angle independence at the operation frequency. This homogeneous slab can be used in one and two dimensional situations for the realization of an invisibility cloak, a carpet cloak and even a skin cloak, if it is used to conformally cover target objects.

  12. Progressive frontal morphology changes during the first year of a modified Pi procedure for scaphocephaly.

    Science.gov (United States)

    Raposo-Amaral, Cassio Eduardo; Denadai, Rafael; Takata, João Paulo Issamu; Ghizoni, Enrico; Buzzo, Celso Luiz; Raposo-Amaral, Cesar Augusto

    2016-02-01

    The purpose of this study was to quantify the changes in frontal morphology in patients with scaphocephaly treated with a modified Pi procedure. Consecutive scaphocephalic patients (n = 13) who underwent surgery before 12 months of age that had more than 1 year of follow-up and standard preoperative, 3-month, and 1-year photographs were included. Anthropometric measurements were used to document the craniofacial index. Computerized photogrammetric analyses of five craniofacial angles (bossing angle, nasofrontal angle, angle of facial convexity, and angle of total facial convexity) were also performed. Comparisons of the preoperative and postoperative direct anthropometric measurements of the cephalic index showed a significant (all p < 0.05) increase in the postoperative period, with no significant differences in early versus late postoperative period comparisons. Comparisons of the preoperative and postoperative computerized photogrammetric measurements of the craniofacial angles showed a significant (all p < 0.05) reduction (bossing angle, angle of facial convexity, and angle of total facial convexity) and increase (nasofrontal angle) in the early and late postoperative periods. Frontal morphology significantly changed over the first year of the modified Pi procedure.

  13. Modified french osteotomy for cubitus varus deformity

    International Nuclear Information System (INIS)

    Ahmad, I.; Idrees, M.

    2007-01-01

    To evaluate the outcome of Modified French Osteotomy for correction of cubitus varus deformity. All children, aged 3-12 years, with cubitus varus deformity were included in the study. Pre-operative clinical as well as radiological assessment of upper extremities were done in all cases. Modified French osteotomy was done to correct the deformity. All patients were followed for seven months. Physical examination for the range of motion, scar and post-operative complications were assessed. Antero-posterior and lateral radiographs of the elbow were obtained, and the carrying angles and lateral condylar prominence index were measured and recorded. Out of the total 30 patients, 26 were male and four female. Left side was involved in 24 cases and the right side in six. The average age at the time of osteotomy was seven years (range 3.5-12 years). The average pre-operative carrying angle was 25.2 degree (range 18-30 degree) and the post-operative angle 8.7 degree (range 5-13 degree valgus). The average pre- operative range of motion was 122.6 degree (range 105-135 degree) and the post-operative range 123.86 degree (range 90-135 degree). The average pre-operative lateral condylar prominence index (LCPI) was 175.56 (range 128-232) and the post-operative lateral condylar prominence 156 (range 100-240). Based on Bellmore criteria, 25 patients showed excellent, three good and two a poor result. Modified French technique of supracondylar osteotomy has excellent results in the management of cubitus varus in terms of cosmesis, radiological findings and fewer complications. (author)

  14. Effect of irradiation angle on the efficiency of formation of multiply charged ions in a laser-produced plasma

    International Nuclear Information System (INIS)

    Bedilov, M R; Beisembaeva, Kh B; Tsoi, T G; Satybaldiev, T B; Sabitov, M S

    2000-01-01

    Mass spectrometry is used to investigate the emission behaviour and the characteristics of multiply charged ions in a plasma produced at small angles of incidence of laser radiation (α∼20 0 ) and also at grazing incidence (α∼85 0 ). It is found that upon grazing incidence of the laser radiation onto a target, the efficiency of production of multiply charged ions is reduced compared to that for α∼20 0 . However, this geometry of laser irradiation of solids can be used for the elemental analysis of surface layers of a sample. (interaction of laser radiation with matter. laser plasma)

  15. Angle-averaged Compton cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: ..cap alpha.. = initial photon energy in units of m/sub 0/c/sup 2/; ..cap alpha../sub s/ = scattered photon energy in units of m/sub 0/c/sup 2/; ..beta.. = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV.

  16. On the dip angle of subducting plates

    Science.gov (United States)

    Hsui, Albert T.; Tang, Xiao-Ming; Toksoz, M. Nafi

    1990-01-01

    A new approximate analytic model is developed for the thermal structure of a subducting plate with a finite length. This model provides the capability of easily examining the thermal and mechanical structure of a subducting plate with different lengths and at different angles. Also, the torque balance of a descending plate can be examined, and effects such as the leading edge effect, the adiabatic compression effect, and the phase change effect can be incorporated. A comparison with observed data indicates that short slabs are likely under torque equilibrium at present, while long slabs are probably dominated by their gravitational torques such that their dip angles are transient, moving toward a steeper dip angle similar to that of the Mariana slab.

  17. Angle-averaged Compton cross sections

    International Nuclear Information System (INIS)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: α = initial photon energy in units of m 0 c 2 ; α/sub s/ = scattered photon energy in units of m 0 c 2 ; β = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV

  18. Precision measurements of the CKM angle gamma

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The level of CP-violation permitted within the Standard Model cannot account for the matter dominated universe in which we live. Within the Standard Model the CKM matrix, which describes the quark couplings, is expected to be unitary. By making precise measurements of the CKM matrix parameters new physics models can be constrained, or with sufficient precision the effects of physics beyond the standard model might become apparent. The CKM angle gamma is the least well known angle of the unitarity triangle. It is the only angle easily accessible at tree-level, and furthermore has almost no theoretical uncertainties. Therefore it provides an invaluable Standard Model benchmark against which other new physics sensitive tests of the CP-violation can be made. I will discuss recent measurements of gamma using the the Run 1 LHCb dataset, which improve our knowledge of this key parameter.

  19. Flocking and invariance of velocity angles.

    Science.gov (United States)

    Liu, Le; Huang, Lihong; Wu, Jianhong

    2016-04-01

    Motsch and Tadmor considered an extended Cucker-Smale model to investigate the flocking behavior of self-organized systems of interacting species. In this extended model, a cone of the vision was introduced so that outside the cone the influence of one agent on the other is lost and hence the corresponding influence function takes the value zero. This creates a problem to apply the Motsch-Tadmor and Cucker-Smale method to prove the flocking property of the system. Here, we examine the variation of the velocity angles between two arbitrary agents, and obtain a monotonicity property for the maximum cone of velocity angles. This monotonicity permits us to utilize existing arguments to show the flocking property of the system under consideration, when the initial velocity angles satisfy some minor technical constraints.

  20. A heterodyne interferometer for angle metrology

    International Nuclear Information System (INIS)

    Hahn, Inseob; Weilert, M.; Wang, X.; Goullioud, R.

    2010-01-01

    We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/√(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately ±0.15 mrad, and 3 μrad rms, respectively.

  1. Spin-wave dynamics in Invar Fe65Ni35 studied by small-angle polarized neutron scattering

    NARCIS (Netherlands)

    Brück, E.H.; Grigoriev, S.V.; Deriglazov, V.V.; Okorokov, A.I.; Dijk van, N.H.; Klaasse, J.C.P.

    2002-01-01

    Abstract. Spin dynamics in Fe65Ni35 Invar alloy has been studied by left-right asymmetry of small-angle polarized neutron scattering below TC=485 K in external magnetic fields of H=0.05-0.25 T inclined relative to the incident beam. The spin-wave stiffness D and the damping & were obtained by

  2. Electron emission induced by resonant coherent ion-surface interaction at grazing incidence

    International Nuclear Information System (INIS)

    Garcia de Abajo, F.J.; Ponce, V.H.; Echenique, P.M.

    1992-01-01

    A new spectroscopy based on the resonant coherently induced electron loss to the continuum in ion-surface scattering under grazing incidence is proposed. A series of peaks, corresponding to the energy differences determined by the resonant interaction with the rows of atoms in the surface, is predicted to appear in the energy distribution of electrons emitted from electronic states bound to the probe. Calculations for MeV He + ions scattered at a W(001) surface along the left-angle 100 right-angle direction with a glancing angle of 0--2 mrad show a total yield close to 1

  3. Theory and tests of a thermal ion detector sensitive only at Near-normal incidence

    Science.gov (United States)

    Robinson, J. W.

    1981-01-01

    Measurements of thermal ions are influenced by factors such as spacecraft potential, velocity, angle of attack, and sheath size. A theory is presented for the response of an instrument which accepts ions only within a small angle of incidence from normal. Although a more general theory is available and forms the basis of this one, the small angle restriction allows a simpler formulation which does not depend on sheath size. Furthermore, practical instruments are easily designed around this restriction. Laboratory tests verify that such instruments respond as expected and they illustrate how design details influence perturbations from the ideal response characteristics.

  4. Positron Emission Mammography with Multiple Angle Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FDG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three- dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  5. Positron Emission Mammography with Multiple Angle Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FbG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three-dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  6. Properties of Direct Coal Liquefaction Residue Modified Asphalt Mixture

    Directory of Open Access Journals (Sweden)

    Jie Ji

    2017-01-01

    Full Text Available The objectives of this paper are to use Direct Coal Liquefaction Residue (DLCR to modify the asphalt binders and mixtures and to evaluate the performance of modified asphalt mixtures. The dynamic modulus and phase angle of DCLR and DCLR-composite modified asphalt mixture were analyzed, and the viscoelastic properties of these modified asphalt mixtures were compared to the base asphalt binder SK-90 and Styrene-Butadiene-Styrene (SBS modified asphalt mixtures. The master curves of the asphalt mixtures were shown, and dynamic and viscoelastic behaviors of asphalt mixtures were described using the Christensen-Anderson-Marasteanu (CAM model. The test results show that the dynamic moduli of DCLR and DCLR-composite asphalt mixtures are higher than those of the SK-90 and SBS modified asphalt mixtures. Based on the viscoelastic parameters of CAM models of the asphalt mixtures, the high- and low-temperature performance of DLCR and DCLR-composite modified asphalt mixtures are obviously better than the SK-90 and SBS modified asphalt mixtures. In addition, the DCLR and DCLR-composite modified asphalt mixtures are more insensitive to the frequency compared to SK-90 and SBS modified asphalt mixtures.

  7. Angles between Curves in Metric Measure Spaces

    Directory of Open Access Journals (Sweden)

    Han Bang-Xian

    2017-09-01

    Full Text Available The goal of the paper is to study the angle between two curves in the framework of metric (and metric measure spaces. More precisely, we give a new notion of angle between two curves in a metric space. Such a notion has a natural interplay with optimal transportation and is particularly well suited for metric measure spaces satisfying the curvature-dimension condition. Indeed one of the main results is the validity of the cosine formula on RCD*(K, N metric measure spaces. As a consequence, the new introduced notions are compatible with the corresponding classical ones for Riemannian manifolds, Ricci limit spaces and Alexandrov spaces.

  8. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    Abstract. The morphology of carbon nanofoam samples comprising platinum nanopar- ticles dispersed in the matrix was characterized by small angle neutron scattering (SANS) and small angle X-ray scattering (SAXS) techniques. Results show that the structure of pores of carbon matrix exhibits a mass (pore) fractal nature ...

  9. Using Digital Technology to See Angles from Different Angles. Part 2: Openings and Turns

    Science.gov (United States)

    Host, Erin; Baynham, Emily; McMaster, Heather

    2015-01-01

    Ever wondered how to use technology to teach angles? This article follows on from an earlier article published last year, providing a range of ideas for integrating technology and concrete materials with the teaching of angle concepts. The authors also provide a comprehensive list of free online games and learning objects that can be used to teach…

  10. Long-term outcomes after acute primary angle closure of Caucasian chronic angle closure glaucoma patients.

    Science.gov (United States)

    Fea, Antonio Maria; Dallorto, Laura; Lavia, Carlo; Pignata, Giulia; Rolle, Teresa; Aung, Tin

    2017-07-19

    There is a lack of information about long-term results of chronic angle closure glaucoma following an acute primary angle closure attack in Caucasian patients. The aim of the study was to report morphological and functional long-term data of chronic angle closure eyes following a monolateral primary angle closure attack and to provide a comparison with their fellow eyes. Observational retrospective case series. Fifty-seven consecutive patients (114 eyes) underwent long-term follow-up analysis. Patients underwent ophthalmic assessment more than 5 years since the angle closure attack. Intraocular pressure, best-corrected visual acuity, angle assessment, vertical C/D ratio and standard automated perimetry were the main outcome measures. Comparisons were made between angle closure attack eyes and fellow eyes and between phakic and pseudophakic eyes. Mean follow-up time was 5.86 ± 1.19 years. A significant greater damage in the angle closure eyes compared with fellow eyes in both structural (mean C/D 0.61 ± 0.16; P APAC attack to prevent potential glaucoma damage in both APAC and fellow eye. © 2017 The Authors Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.

  11. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085, India. *Corresponding author ... ticles dispersed in the matrix was characterized by small angle neutron scattering (SANS) and small angle X-ray ... for scattering from rough pore–mass interfaces, α > 3 and the (surface) fractal dimension Ds = 6 ...

  12. Sharper angle, higher risk? The effect of cutting angle on knee mechanics in invasion sport athletes

    NARCIS (Netherlands)

    Schreurs, Mervin J.; Benjaminse, Anne; Lemmink, Koen A. P. M.

    2017-01-01

    Introduction: Cutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles. Material and methods: 13 males and 16 females performed cuts at different angles (45°, 90°,

  13. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... Small angle neutron scattering and small angle X-ray scattering studies of platinum-loaded carbon foams. P U Sastry V K Aswal A G Wagh ... Proceedings of the International Workshop/Conference on Computational Condensed Matter Physics and Materials Science (IWCCMP-2015). Posted on November ...

  14. Incident energy and charge deposition dependences of electron transmission through a microsized tapered glass capillary

    Energy Technology Data Exchange (ETDEWEB)

    Wickramarachchi, S.J. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States); Ikeda, T. [RIKEN Nishina Center for Accelerator Based Science, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Dassanayake, B.S. [Department of Physics, Faculty of Science, University of Peradeniya (Sri Lanka); Keerthisinghe, D.; Tanis, J.A. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States)

    2016-09-01

    An experimental study of electron transmission and guiding through a tapered glass capillary has been performed. Electrons were transmitted for tilt angles up to ∼6.5° and ∼9.5° (laboratory angles) for incident energies of 500 and 1000 eV, respectively. It is found that elastic and inelastic contributions give rise to distinguishable peaks in the transmitted profile. For 500 eV elastic transmission dominates the profile, while for 1000 eV both elastic and inelastic contributions are present. The transmission for both energies was studied as a function of the charge (time) deposition and found to be strongly dependent. Results suggest fundamental differences between 500 and 1000 eV incident electrons. For 500 eV the transmission slowly increases suggesting charge up of the capillary wall, reaching relative stability with infrequent breakdowns for all angles investigated. For 1000 eV for tilt angles near zero degrees the time dependent profile shows oscillations in the transmission, which never reached a stable condition, while for the larger angle investigated the transmission reached near equilibrium. Inelastic processes dominated the transmission for 1000 eV even at very small tilt angles, but was generally elastic (due to Coulomb deflection) for 500 eV even for the largest tilt angle measured.

  15. Grazing Incidence Optics Technology

    Science.gov (United States)

    Ramsey, Brian; Smith, W. Scott; Gubarev, Mikhail; McCracken, Jeff

    2015-01-01

    This project is to demonstrate the capability to directly fabricate lightweight, high-resolution, grazing-incidence x-ray optics using a commercially available robotic polishing machine. Typical x-ray optics production at NASA Marshall Space Flight Center (MSFC) uses a replication process in which metal mirrors are electroformed on to figured and polished mandrels from which they are later removed. The attraction of this process is that multiple copies can be made from a single master. The drawback is that the replication process limits the angular resolution that can be attained. By directly fabricating each shell, errors inherent in the replication process are removed. The principal challenge now becomes how to support the mirror shell during all aspects of fabrication, including the necessary metrology to converge on the required mirror performance specifications. This program makes use of a Zeeko seven-axis computer-controlled polishing machine (see fig. 1) and supporting fabrication, metrology, and test equipment at MSFC. The overall development plan calls for proof-of-concept demonstration with relatively thick mirror shells (5-6 mm, fig. 2) which are straightforward to support and then a transition to much thinner shells (2-3 mm), which are an order of magnitude thinner than those used for Chandra. Both glass and metal substrates are being investigated. Currently, a thick glass shell is being figured. This has enabled experience to be gained with programming and operating the polishing machine without worrying about shell distortions or breakage. It has also allowed time for more complex support mechanisms for figuring/ polishing and metrology to be designed for the more challenging thinner shells. These are now in fabrication. Figure 1: Zeeko polishing machine.

  16. Goiania incident case study

    International Nuclear Information System (INIS)

    Petterson, J.S.

    1988-06-01

    The reasons for wanting to document this case study and present the findings are simple. According to USDOE technical risk assessments (and our own initial work on the Hanford socioeconomic study), the likelihood of a major accident involving exposure to radioactive materials in the process of site characterization, construction, operation, and closure of a high-level waste repository is extremely remote. Most would agree, however, that there is a relatively high probability that a minor accident involving radiological contamination will occur sometime during the lifetime of the repository -- for example, during transport, at an MRS site or at the permanent site itself during repacking and deposition. Thus, one of the major concerns of the Yucca Mountain Socioeconomic Study is the potential impact of a relatively minor radiation-related accident. A large number of potential impact of a relatively minor radiation-related accident. A large number of potential accident scenarios have been under consideration (such as a transportation or other surface accident which results in a significant decline in tourism, the number of conventions, or the selection of Nevada as a retirement residence). The results of the work in Goiania make it clear, however, that such a significant shift in established social patterns and trends is not likely to occur as a direct outcome of a single nuclear-related accident (even, perhaps, a relatively major one), but rather, are likely to occur as a result of the enduring social interpretations of such an accident -- that is, as a result of the process of understanding, communicating, and socially sustaining a particular set of associations with respect to the initial incident

  17. X-ray small angle scattering of polymer solutions

    International Nuclear Information System (INIS)

    Koyama, Ryuzo

    1975-01-01

    In recent papers, the calculated results were reported on the angular dependence of the intensity of scattered light or X-ray by chain polymers, on the basis of a stiff chain model. As the results, the curves of S 2 P (theta) corresponding to Kratky plot, for different molecular expansion, showed a plateau, and the height of the plateau was proportional to the inverse of molecular expansion coefficient α 2 . But as seen later, there is some possibility that the assumption made in the calculation overestimated the expansion of small segments which theoretically determines scattering curves at large scattering angles, such as the plateau. Accordingly, modified calculation was carried out by adopting the stiff chain polymer model as the previous case. When the contour length of a chain segment is very long, it can be treated approximately as a Gaussian coil, thus the equation for a chain segment expansion coefficient α (t) was obtained. Then the mean square distance of chain segments of polymer molecules was able to be determined, and the equation for a particle scattering factor P(theta) was obtained. The numerical calculation of P(theta) showed that this modified assumption considerably decreased the effect of molecular expansion on P(theta), and the curves of S 2 P(theta) increased monotonously without showing the plateau. The result of this calculation was compared with the experimental curves of polystyrene-toluene solution, and the agreement better than before was obtained. (Kako, I.)

  18. Angle at the Medial Border: The Spinovertebra Angle and Its Significance

    Directory of Open Access Journals (Sweden)

    G. S. Oladipo

    2015-01-01

    Full Text Available Background. The evolution from quadrupedalism to bipedalism has adjusted the balance of the upper limb to extensive movement at the shoulder. The scapular angles provide the point of attachment and control to various muscles and have been associated with the different movements of the shoulder girdle and joint. This has made the morphometric and anthropometric study of scapula a subject of extensive investigation. Aim. In the present study, the angle at the medial border was measured in the South-Southern Nigerian population and an anatomical name was ascribed to the angle. Method. The study was conducted on 173 scapulae (75 right and 98 left obtained from various Anatomy Department of South-Sothern Nigerian Universities. The angle at medial border was obtained by pinning the edge of the superior and inferior angles, the lined traced out, and the angle measured using a protractor. SPSS version 20 was used to analyse the data. t-test was used to determine mean angular difference in the sides. Result. The mean ± SD of the medial angle was observed to be 136.88 ± 7.70° (R = 138.13 ± 7.06° : L = 135.92 ± 8.05°. Statistical analysis using the Z-test for mean difference showed the medial angle was found to be higher in the right side of the scapula (mean difference of 2.214 ± 1.152°, but the observed difference was not statistically significant (P > 0.05. The above findings have adjusted the scapula from three to four angles (lateral, superior, inferior, and medial formed from four borders (lateral, superior, inferior, and superomedial and inferomedial. The medial angle because of its anatomical location was named “spinovertebral” angle, owing to its position at the scapulae spine, and located in medial proximity to the vertebra column. Conclusion. The medial angle (now referred to as the spinovertebral angle of the right side of the scapula is wider than the left. The representation of the spinovertebral angle is very important, as

  19. Prediction of static contact angles on the basis of molecular forces and adsorption data.

    Science.gov (United States)

    Diaz, M Elena; Savage, Michael D; Cerro, Ramon L

    2016-08-01

    At a three-phase contact line, a liquid bulk phase is in contact with and coexists with a very thin layer of adsorbed molecules. This adsorbed film in the immediate vicinity of a liquid wedge modifies the balance of forces between the liquid and solid phases such that, when included in the balance of forces, a quantitative relationship emerges between the adsorbed film thickness and the static contact angle. This relationship permits the prediction of static contact angles from molecular forces and equilibrium adsorption data by means of quantities that are physically meaningful and measurable. For n-alkanes on polytetrafluoroethylene, for which there are experimental data available on adsorption and contact angles, our computations show remarkable agreement with the data. The results obtained are an improvement on previously published calculations-particularly for alkanes with a low number of carbon atoms, for which adsorption is significant.

  20. In situ measurements of the oblique incidence sound absorption coefficient for finite sized absorbers

    DEFF Research Database (Denmark)

    Ottink, Marco; Brunskog, Jonas; Jeong, Cheol-Ho

    2016-01-01

    for the finiteness of the absorber. A sound field model, which accounts for scattering from the finite absorber edges, assuming plane wave incidence is derived. A significant influence of the finiteness on the radiation impedance and the corresponding absorption coefficient is found. A finite surface method, which......Absorption coefficients are mostly measured in reverberation rooms or with impedance tubes. Since these methods are only suitable for measuring the random incidence and the normal incidence absorption coefficient, there exists an increasing need for absorption coefficient measurement of finite...... absorbers at oblique incidence in situ. Due to the edge diffraction effect, oblique incidence methods considering an infinite sample fail to measure the absorption coefficient at large incidence angles of finite samples. This paper aims for the development of a measurement method that accounts...

  1. Effects of Rayleigh damping, friction and rate-dependency on 3D residual stress simulation of angled shot peening

    International Nuclear Information System (INIS)

    Kim, Taehyung; Lee, Hyungyil; Hyun, Hong Chul; Jung, Sunghwan

    2013-01-01

    Highlights: ► We propose a 3D FE model to study peening residual stress involving angled shots. ► The FE model set with plastic shot are found to best match the X-ray diffraction data. ► The model provides 3D multi-shot impact FE solution with various incidence angles. - Abstract: In this study, we propose a 3D finite element (FE) model to study shot peening involving angled shots. Using the FE model for angled shot peening, we examine relationships with the residual stress introduced by shot peening of the factors such as the Rayleigh damping in the material, dynamic friction, and the rate dependency of the material and systematically integrate them with the FE model. The FE model is set with rigid shot, elastic shot, and plastic shot respectively. Plastic deformation of the shot is also explored with the FE model. The FE model is applied to study angled multi-shots. The FE results are verified with experimental data using X-ray diffraction (XRD). The FE model set with plastic shot are found to best match the XRD results validating accuracy of the 3D FE model properly integrated with the factors and plastically deformable shot ball. The proposed model will serve to simulate actual shot peening cases, which generally involve multi-shots with various incidence angles

  2. Pythagoras and Cosines: The skin-dural sac distance and optimal angles in paramedian spinal anesthesia.

    Science.gov (United States)

    Puigdellívol-Sánchez, Anna; Reina, Miguel A; Sala-Blanch, Xavier; Pomés-Talló, Jaume; Prats-Galino, Alberto

    2016-11-01

    The classical recommendation for paramedian approaches is needle insertion 1-2 cm paramedian and an angle of 10°-15° medial-cephalad to the plane of the back, but contact with vertebrae is frequent. A mathematical approach to individualizing punctures is proposed on the basis of skin-dural sac distance (d): Optimal angle ∼ inverse cosine [d/ √(1+d^2) ] and the distance covered by the needle ∼ √(1+d^2) for 1 cm paramedian punctures. The inferred angles were compared to optimal angles leading to the central dorsal part of the dural sac from 1 to 2 cm paramedian, measured by Magnetic Resonance Imaging (MRI) in seven cases and in a short stature volunteer (1.58 m, Body Mass Index (BMI) 23.2), to study supine and fetal positions using both closed MR and ultrasound. The average (d) decreased rostrally [6.8 cm (L4-L5)-4.3 cm (T11-T12)] while the mean optimal incidence angles increased [8.3°-16.5° (L4-L5) to 12.7°-24.1° (T11-T12) at 1-2 cm paramedian, respectively] and coincided with the estimated angles with a correlation coefficient = 0.98. In the volunteer, the optimal lateromedial angles increased from 14.4° to 26.7° (L3-L4) to 17.1°-30.3° (T11-T12) for a (d) = 3.7 cm (L3-L4)-3.1 cm (T11-T12) and increased ≤3.7° and ≤5.1° at 1 and 2 cm paramedian, respectively, in fetal positions in MR. Ultrasound yielded comparable figures. The range of possible angles for dural punctures is wider at 1 cm paramedian in lower approaches in lateral decubitus [from 3.6° at T12L1 (12.2°-15.8°) to 9° at L3L4 (8.8°-18.7°)]. The classically recommended angles of 10°-15° differ from the optimal angles, particularly in small patients, suggesting the need for ultrasound guidance or for inferring angles prior to spinal anesthesia. Clin. Anat. 29:1046-1052, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Edge Contact Angle and Modified Kelvin Equation for Condensation in Open Pores.

    Czech Academy of Sciences Publication Activity Database

    Malijevský, Alexandr; Parry, A.O.; Pospíšil, M.

    2017-01-01

    Roč. 96, č. 2 (2017), č. článku 020801. ISSN 2470-0045 R&D Projects: GA ČR(CZ) GA17-25100S Grant - others:EPSRC(GB) EP/L020564/1 Institutional support: RVO:67985858 Keywords : capillary condensation * Kelvin equation * density functional theory Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 2.366, year: 2016

  4. FPGA Based Modified Fuzzy PID Controller for Pitch Angle of Bench-top Helicopter

    OpenAIRE

    A.A. Aldair

    2012-01-01

    Fuzzy PID controller design is still a complex task due to the involvement of a large number of parameters in defining the fuzzy rule base. To reduce the huge number of fuzzy rules required in the normal design for fuzzy PID controller, the fuzzy PID controller is represented as Proportional-Derivative Fuzzy (PDF) controller and Proportional-Integral Fuzzy (PIF) controller connected in parallel through a summer. The PIF controller design has been simplified by replacing the PIF controller by ...

  5. Small-angle neutron scattering by water-based ferrofluid mixed with polyethylene glycol

    International Nuclear Information System (INIS)

    Feoktystov, A.V.; Avdeev, M.V.; Feoktystov, A.V.; Garamus, V.M.; Feoktystov, A.V.; Bulavin, L.A.; Kopcansky, P.; Timko, M.; Koneracka, M.; Zavisova, V.

    2009-01-01

    A new approach in the contrast variation experiments (small-angle neutron scattering) is demonstrated with a complex water-based magnetic fluid, where magnetite nanoparticles (size about 10 nm) coated with sodium oleate are mixed with poly(ethylene glycol), PEG. The contrast variations is performed basing on the substitution of hydrogen with deuterium in the liquid carrier (water). Modified basic functions defined for the polydisperse multicomponent superparamagnetic system are analyzed

  6. In situ measurements of the oblique incidence sound absorption coefficient for finite sized absorbers.

    Science.gov (United States)

    Ottink, Marco; Brunskog, Jonas; Jeong, Cheol-Ho; Fernandez-Grande, Efren; Trojgaard, Per; Tiana-Roig, Elisabet

    2016-01-01

    Absorption coefficients are mostly measured in reverberation rooms or with impedance tubes. Since these methods are only suitable for measuring the random incidence and the normal incidence absorption coefficient, there exists an increasing need for absorption coefficient measurement of finite absorbers at oblique incidence in situ. Due to the edge diffraction effect, oblique incidence methods considering an infinite sample fail to measure the absorption coefficient at large incidence angles of finite samples. This paper aims for the development of a measurement method that accounts for the finiteness of the absorber. A sound field model, which accounts for scattering from the finite absorber edges, assuming plane wave incidence is derived. A significant influence of the finiteness on the radiation impedance and the corresponding absorption coefficient is found. A finite surface method, which combines microphone array measurements over a finite sample with the sound field model in an inverse manner, is proposed. Besides, a temporal subtraction method, a microphone array method, impedance tube measurements, and an equivalent fluid model are used for validation. The finite surface method gives promising agreement with theory, especially at near grazing incidence. Thus, the finite surface method is proposed for further measurements at large incidence angles.

  7. Brief communication: Lumbar lordosis in extinct hominins: implications of the pelvic incidence.

    Science.gov (United States)

    Been, Ella; Gómez-Olivencia, Asier; Kramer, Patricia A

    2014-06-01

    Recently, interest has peaked regarding the posture of extinct hominins. Here, we present a new method of reconstructing lordosis angles of extinct hominin specimens based on pelvic morphology, more specifically the orientation of the sacrum in relation to the acetabulum (pelvic incidence). Two regression models based on the correlation between pelvic incidence and lordosis angle in living hominoids have been developed. The mean values of the calculated lordosis angles based on these models are 36°-45° for australopithecines, 45°-47° for Homo erectus, 27°-34° for the Neandertals and the Sima de los Huesos hominins, and 49°-51° for fossil H. sapiens. The newly calculated lordosis values are consistent with previously published values of extinct hominins (Been et al.: Am J Phys Anthropol 147 (2012) 64-77). If the mean values of the present nonhuman hominoids are representative of the pelvic and lumbar morphology of the last common ancestor between humans and nonhuman hominoids, then both pelvic incidence and lordosis angle dramatically increased during hominin evolution from 27° ± 5 to 22° ± 3 (respectively) in nonhuman hominoids to 54° ± 10 and 51° ± 11 in modern humans. This change to a more human-like configuration appeared early in the hominin evolution as the pelvis and spines of both australopithecines and H. erectus show a higher pelvic incidence and lordosis angle than nonhuman hominoids. The Sima de los Huesos hominins and Neandertals show a derived configuration with a low pelvic incidence and lordosis angle. Copyright © 2014 Wiley Periodicals, Inc.

  8. Real time freeway incident detection.

    Science.gov (United States)

    2014-04-01

    The US Department of Transportation (US-DOT) estimates that over half of all congestion : events are caused by highway incidents rather than by rush-hour traffic in big cities. Real-time : incident detection on freeways is an important part of any mo...

  9. CKM matrix exponential parametrization and Euler angles

    International Nuclear Information System (INIS)

    Dattoli, G.; Sabia, E.; Torre, A.

    1997-01-01

    They show that the exponential parametrization of the CKM matrix allows to establish exact relations between the Euler weak rotation angles and the entries of the CKM generating matrix, which has already been shown to include the hierarchy features of the Wolfenstein parametrization. The analysis includes CP-violating effects and its usefulness to treat the experimental data is also proved

  10. Gaugings at angles from orientifold reductions

    NARCIS (Netherlands)

    Roest, D.

    2009-01-01

    We consider orientifold reductions to N = 4 gauged supergravity in four dimensions. A special feature of this theory is that different factors of the gauge group can have relative angles with respect to the electro-magnetic SL(2) symmetry. These are crucial for moduli stabilization and de Sitter

  11. Experimental technique of small angle neutron scattering

    International Nuclear Information System (INIS)

    Xia Qingzhong; Chen Bo

    2006-03-01

    The main parts of Small Angle Neutron Scattering (SANS) spectrometer, and their function and different parameters are introduced from experimental aspect. Detailed information is also introduced for SANS spectrometer 'Membrana-2'. Based on practical experiments, the fundamental requirements and working condition for SANS experiments, including sample preparation, detector calibration, standard sample selection and data preliminary process are described. (authors)

  12. The resection angle in apical surgery

    DEFF Research Database (Denmark)

    von Arx, Thomas; Janner, Simone F M; Jensen, Simon S

    2016-01-01

    OBJECTIVES: The primary objective of the present radiographic study was to analyse the resection angle in apical surgery and its correlation with treatment outcome, type of treated tooth, surgical depth and level of root-end filling. MATERIALS AND METHODS: In the context of a prospective clinical...

  13. A thin film magnetoresistive angle detector

    NARCIS (Netherlands)

    Eijkel, C.J.M.; Wieberdink, Johan W.; Fluitman, J.H.J.; Popma, T.J.A.; Groot, Peter; Leeuwis, Henk

    1990-01-01

    An overview is given of the results of our research on a contactless angle detector based on the anisotropic magnetoresistance effect (AMR effect) in a permalloy thin film. The results of high-temperature annealing treatment of the pemalloy film are discussed. Such a treatment suppresses the effects

  14. A small-angle neutron scattering study

    Indian Academy of Sciences (India)

    400Da [9]. Low-angle X-ray scattering [10] and neutron scattering [11] also in- dicated serum albumin to be a prolate ellipsoid. However, studies using 1H NMR indicated that a prolate structure was unlikely; rather a heart-shaped structure was proposed [12]. The shape of albumin reveals a heart-shaped molecule that can.

  15. Solid angle subtended by two circular discs

    International Nuclear Information System (INIS)

    Gilly, Louis.

    1978-09-01

    Methods of calculation of solid angles, subtended by two circular discs are analysed. Calculus are methodically classified as follow: series development Legendre polynomes, defined integral, elliptic integrals, Bessel integrals, multiple integrals, Monte Carlo method, electrostatic analogy. Applications in Nuclear Physics are added as examples. List of numeric tables completes bibliography [fr

  16. Small Angle Light Scattering by Biological Objects

    International Nuclear Information System (INIS)

    Berdzenishvili, L.; Melikishvili, Z.

    2005-01-01

    In this paper the small angle laser radiation scattering by the particles of different shape and size is analyzed. Experimental results and theoretical calculations show that after ejection from bacteriophage DNA forms the scattering medium consisted of quasi-spherical elements with radius of R⁓10λ 0 . (author)

  17. Direct angle resolved photoemission spectroscopy and ...

    Indian Academy of Sciences (India)

    Since 1997 we systematically perform direct angle resolved photoemission spectroscopy (ARPES) on in-situ grown thin (< 30 nm) cuprate films. Specifically, we probe low-energy electronic structure and properties of high-c superconductors (HTSC) under different degrees of epitaxial (compressive vs. tensile) strain.

  18. Right-Angle Mechanized Electrical Connector

    Science.gov (United States)

    Collins, Clint A.; Blackler, David T.

    1996-01-01

    Right-angle electrical connector embedded in mechanism accommodates some initial misalignment and aligns itself. Connection and disconnection effected with relatively small forces and torques and simple movements. Actuated by one gloved hand or by robotic manipulator. Useful in underwater, nuclear, hot, cold, or toxic environments in which connections made or broken by heavily clothed technicians or by robots.

  19. A small angle neutron scattering study

    Indian Academy of Sciences (India)

    Nanocrystalline nickel oxide powders were calcined at 300, 600 and 900°C and pore structure evolution was followed by small angle neutron scattering (SANS). Pore size distributions at two widely separated size ranges have been revealed. Shrinkage of larger-sized pore with reduction in polydispersity has been observed ...

  20. SANS-1: Small angle neutron scattering

    Directory of Open Access Journals (Sweden)

    André Heinemann

    2015-08-01

    Full Text Available The new small angle scattering instrument SANS-1, jointly operated by the Technische Universität München and GEMS, Helmholtz-Zentrum Geesthacht, has completed commissioning and is in regular user service (Gilles et al., 2006. SANS-1 is located at the end of neutron guide NL4a in the Neutron Guide Hall West.

  1. SANS-1: Small angle neutron scattering

    OpenAIRE

    Heinemann, André; Mühlbauer, Sebastian

    2015-01-01

    The new small angle scattering instrument SANS-1, jointly operated by the Technische Universität München and GEMS, Helmholtz-Zentrum Geesthacht, has completed commissioning and is in regular user service (Gilles et al., 2006). SANS-1 is located at the end of neutron guide NL4a in the Neutron Guide Hall West.

  2. Camber Angle Inspection for Vehicle Wheel Alignments.

    Science.gov (United States)

    Young, Jieh-Shian; Hsu, Hong-Yi; Chuang, Chih-Yuan

    2017-02-03

    This paper introduces an alternative approach to the camber angle measurement for vehicle wheel alignment. Instead of current commercial approaches that apply computation vision techniques, this study aims at realizing a micro-control-unit (MCU)-based camber inspection system with a 3-axis accelerometer. We analyze the precision of the inspection system for the axis misalignments of the accelerometer. The results show that the axes of the accelerometer can be aligned to the axes of the camber inspection system imperfectly. The calibrations that can amend these axis misalignments between the camber inspection system and the accelerometer are also originally proposed since misalignments will usually happen in fabrications of the inspection systems. During camber angle measurements, the x -axis or z -axis of the camber inspection system and the wheel need not be perfectly aligned in the proposed approach. We accomplished two typical authentic camber angle measurements. The results show that the proposed approach is applicable with a precision of ± 0.015 ∘ and therefore facilitates the camber measurement process without downgrading the precision by employing an appropriate 3-axis accelerometer. In addition, the measured results of camber angles can be transmitted via the medium such as RS232, Bluetooth, and Wi-Fi.

  3. Camber Angle Inspection for Vehicle Wheel Alignments

    Directory of Open Access Journals (Sweden)

    Jieh-Shian Young

    2017-02-01

    Full Text Available This paper introduces an alternative approach to the camber angle measurement for vehicle wheel alignment. Instead of current commercial approaches that apply computation vision techniques, this study aims at realizing a micro-control-unit (MCU-based camber inspection system with a 3-axis accelerometer. We analyze the precision of the inspection system for the axis misalignments of the accelerometer. The results show that the axes of the accelerometer can be aligned to the axes of the camber inspection system imperfectly. The calibrations that can amend these axis misalignments between the camber inspection system and the accelerometer are also originally proposed since misalignments will usually happen in fabrications of the inspection systems. During camber angle measurements, the x-axis or z-axis of the camber inspection system and the wheel need not be perfectly aligned in the proposed approach. We accomplished two typical authentic camber angle measurements. The results show that the proposed approach is applicable with a precision of ± 0.015 ∘ and therefore facilitates the camber measurement process without downgrading the precision by employing an appropriate 3-axis accelerometer. In addition, the measured results of camber angles can be transmitted via the medium such as RS232, Bluetooth, and Wi-Fi.

  4. A small-angle neutron scattering investigation

    Indian Academy of Sciences (India)

    Hence, the steel is used in aircraft, nuclear reactor, petrochemical plants and many other industries. However, presence of carbide formers such as Mo and Cr war- rants the possibility of carbide precipitates in the structure and in turn affects the mechanical properties. Small-angle neutron scattering (SANS) is an important ...

  5. Contact angle measurement with a smartphone

    Science.gov (United States)

    Chen, H.; Muros-Cobos, Jesus L.; Amirfazli, A.

    2018-03-01

    In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.

  6. Measurement of the angle alpha at BABAR

    International Nuclear Information System (INIS)

    Perez, A.

    2009-01-01

    The authors present recent measurements of the CKM angle α using data collected by the BABAR detector at the PEP-II asymmetric-energy e + e - collider at the SLAC National Accelerator Laboratory, operating at the Υ(4S) resonance. They present constraints on α from B → ππ, B → ρρ and B → ρπ decays.

  7. Evaluation of protein dihedral angle prediction methods.

    Directory of Open Access Journals (Sweden)

    Harinder Singh

    Full Text Available Tertiary structure prediction of a protein from its amino acid sequence is one of the major challenges in the field of bioinformatics. Hierarchical approach is one of the persuasive techniques used for predicting protein tertiary structure, especially in the absence of homologous protein structures. In hierarchical approach, intermediate states are predicted like secondary structure, dihedral angles, Cα-Cα distance bounds, etc. These intermediate states are used to restraint the protein backbone and assist its correct folding. In the recent years, several methods have been developed for predicting dihedral angles of a protein, but it is difficult to conclude which method is better than others. In this study, we benchmarked the performance of dihedral prediction methods ANGLOR and SPINE X on various datasets, including independent datasets. TANGLE dihedral prediction method was not benchmarked (due to unavailability of its standalone and was compared with SPINE X and ANGLOR on only ANGLOR dataset on which TANGLE has reported its results. It was observed that SPINE X performed better than ANGLOR and TANGLE, especially in case of prediction of dihedral angles of glycine and proline residues. The analysis suggested that angle shifting was the foremost reason of better performance of SPINE X. We further evaluated the performance of the methods on independent ccPDB30 dataset and observed that SPINE X performed better than ANGLOR.

  8. Measurement of critical angle in SSTDs

    International Nuclear Information System (INIS)

    Marques, A.; Serra, D.A.B.

    1984-01-01

    A method of measurement of critical angles of etching is described, relying upon the distortion caused in the shape of the distribution in the number of etched tracks of ions emitted from a 'point-like' source. The method is applied to quartz and mica samples. (author)

  9. Contact angle measurement with a smartphone.

    Science.gov (United States)

    Chen, H; Muros-Cobos, Jesus L; Amirfazli, A

    2018-03-01

    In this study, a smartphone-based contact angle measurement instrument was developed. Compared with the traditional measurement instruments, this instrument has the advantage of simplicity, compact size, and portability. An automatic contact point detection algorithm was developed to allow the instrument to correctly detect the drop contact points. Two different contact angle calculation methods, Young-Laplace and polynomial fitting methods, were implemented in this instrument. The performance of this instrument was tested first with ideal synthetic drop profiles. It was shown that the accuracy of the new system with ideal synthetic drop profiles can reach 0.01% with both Young-Laplace and polynomial fitting methods. Conducting experiments to measure both static and dynamic (advancing and receding) contact angles with the developed instrument, we found that the smartphone-based instrument can provide accurate and practical measurement results as the traditional commercial instruments. The successful demonstration of use of a smartphone (mobile phone) to conduct contact angle measurement is a significant advancement in the field as it breaks the dominate mold of use of a computer and a bench bound setup for such systems since their appearance in 1980s.

  10. Intra- and Interobserver Reliability of the Cobb Angle-Vertebral Rotation Angle-Spinous Process Angle for Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Chan, Amanda C Y; Morrison, Devlin G; Nguyen, Duc V; Hill, Douglas L; Parent, Eric; Lou, Edmond H M

    2014-05-01

    A reliability analysis of Cobb angle, vertebral rotation (VR), and spinous process angle (SPA) measurements in adolescent idiopathic scoliosis. To determine the intra- and interobserver reliability of semi-automated digital radiograph measurements. Cobb angle measurements on posteroanterior radiographs are commonly used to determine the severity of scoliosis. Vertebral rotation helps assess scoliosis 3-dimensionally and has a role in predicting curve progression. Recent studies have shown that the spinous process angle is a useful parameter in assessing scoliosis when using ultrasound imaging. Because the reliability of SPA measurements on radiographs has yet to be determined, it is important to compare the reliability of these 3 parameters (Cobb angle, VR, and SPA) using a computer assisted semi-automated method. Sixty posteroanterior radiographs of patients with adolescent idiopathic scoliosis were obtained and measured twice by 3 observers who were blinded to their previous measurements, using an in-house developed program. Measurements were obtained using a semi-automated method to minimize variability resulting from observer reliability. The intra- and interobserver reliabilities were analyzed using intra-class correlation coefficients (ICCs) as well as Bland-Altman's bias and limits of agreement. Over 350 (intra) and 90 (inter) sets of curves with an average Cobb angle of 26° ± 9° (range, 10° to 44°) were compared for each parameter. Intra-observer reliabilities for each parameter were excellent (ICC [2,1] , .82; 1.00), with mean absolute differences under 3° between most measurements. Interobserver reliability (ICC [2,1] , .72; .95) was mostly good to excellent, with mean absolute differences ranging from 2.0° to 5.6°. Both the intra- and interobserver assessment of the Cobb, VR, and SPA from the semi-automated measurements had clinically acceptable reliability ranges and may be considered for clinical implementation. Additional studies will be

  11. Fabrication of superhydrophobic sol-gel composite films using hydrophobically modified colloidal zinc hydroxide.

    Science.gov (United States)

    Lakshmi, R V; Basu, Bharathibai J

    2009-11-15

    A superhydrophobic sol-gel composite film was fabricated by incorporating hydrophobically modified colloidal zinc hydroxide (CZH) in sol-gel matrix. CZH was prepared by controlled precipitation and modified by treatment with stearic acid. The concentration of stearic acid and stirring time were optimized to obtain modified CZH with very high water contact angle (WCA) of 165 degrees and sliding angle (SA)superhydrophobic surfaces. FTIR spectrum also confirmed the presence of zinc stearate in the composite film. The method is simple and cost-effective and does not involve any expensive chemicals or equipments.

  12. Effects of spray angle variation on mixing in a cold supersonic combustor with kerosene fuel

    Science.gov (United States)

    Zhu, Lin; Luo, Feng; Qi, Yin-Yin; Wei, Min; Ge, Jia-Ru; Liu, Wei-Lai; Li, Guo-Li; Jen, Tien-Chien

    2018-03-01

    Effective fuel injection and mixing is of particular importance for scramjet engines to be operated reliably because the fuel must be injected into high-speed crossflow and mixed with the supersonic air at an extremely short time-scale. This study numerically characterizes an injection jet under different spray angles in a cold kerosene-fueled supersonic flow and thus assesses the effects of the spray angle on the mixing between incident shock wave and transverse cavity injection. A detailed computational fluid dynamics model is developed in accordance with the real scramjet combustor. Next, the spray angles are designated as 45°, 90°, and 135° respectively with the other constant operational conditions (such as the injection diameter, velocity and pressure). Next, a combination of a three dimensional Couple Level Set & Volume of Fluids with an improved Kelvin-Helmholtz & Rayleigh-Taylor model is used to investigate the interaction between kerosene and supersonic air. The numerical predictions are focused on penetration depth, span expansion area, angle of shock wave and sauter mean diameter distribution of the kerosene droplets with or without evaporation. Finally, validation has been implemented by comparing the calculated to the measured in literature with good qualitative agreement. Results show that no matter whether the evaporation is considered, the penetration depth, span-wise angle and expansion area of the kerosene droplets are all increased with the spray angle, and most especially, that the size of the kerosene droplets is surely reduced with the spray angle increase. These calculations are beneficial to better understand the underlying atomization mechanism in the cold kerosene-fueled supersonic flow and hence provide insights into scramjet design improvement.

  13. Anatomic predictors for anterior chamber angle opening after laser peripheral iridotomy in narrow angle eyes.

    Science.gov (United States)

    Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Osmonavic, Senad; Leeungurasatien, Thidarat; He, Mingguang; Lin, Shan C

    2012-07-01

    To investigate anterior chamber parameters and biometric factors associated with degree of angle opening after laser peripheral iridotomy (LPI) for narrow angles. In this prospective cohort study, patients with narrow angles who were scheduled for LPI were recruited. Anterior chamber parameters by anterior segment coherence tomography (ASOCT) under dark conditions were compared before and after LPI. Only the right eye was used for analysis if both eyes were eligible. Measurements performed by customized software included anterior chamber depth, iris area, angle opening distance at 500 µm (AOD500) anterior to the scleral spur, iris thickness at 750 µm from sclera spur (IT750), trabecular-iris space area 500 (TISA500), and iris curvature (I-Curv). Univariate and multiple regression analyses were performed to determine the predictive factors of angle opening after LPI. Eighty-one patients with narrow angles were prospectively recruited in this study. The AOD500 increased significantly from 0.128 ± 0.081 mm (before) to 0.209 ± 0.087 mm (after) in the nasal quadrant, and from 0.103 ± 0.067 mm (before) to 0.197 ± 0.071 mm (after) in the temporal quadrant (p chamber angle widening after LPI were older age, smaller iris area, and steeper iris.

  14. Phosphine modified cobalt hydroformylation

    Energy Technology Data Exchange (ETDEWEB)

    Rensburg, H. van; Tooze, R.P.; Foster, D.F. [Sasol Technology UK, St. Andrews (United Kingdom); Janse van Rensburg, W. [Sasol Technology, Sasolburg (South Africa)

    2006-07-01

    An ongoing challenge in phosphine modified cobalt hydroformylation is the fundamental understanding of the electronic and steric properties of phosphine ligands that influence the selectivity and activity of the catalytic reaction. A series of acyclic and cyclic phosphines have been prepared and tested in phosphine modified cobalt hydroformylation of 1-octene. Molecular modelling on a series of phospholanes showed some interesting theoretical and experimental correlations. We also evaluated the use of N-heterocyclic carbenes as an alternative for phosphines in modified cobalt hydroformylation. (orig.)

  15. Development of glancing-incidence and glancing-take-off X-ray fluorescence apparatus for surface and thin-film analyses

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Wagatsuma, Kazuaki; Yamada, Takashi; Utaka, Tadashi

    1997-01-01

    We have studied X-ray fluorescence analysis under glancing incidence and glancing take-off conditions. Recently, we have developed a third apparatus for detecting glancing-incidence and take-off X-ray fluorescence, which makes it possible to measure the incident-angle dependence, the take-off-angle dependence. X-ray reflectivity, and X-ray diffraction. Primarily, we have measured the take-off angular dependence of X-ray fluorescence using this apparatus. Glancing take-off X-ray fluorescence has some advantages in comparison with glancing-incidence X-ray fluorescence. The surface density and the absolute angles were determined by analysing the take-off angle dependence of the fluorescent X-rays emitted from identical atoms with the aid of the reciprocity theorem. (Author)

  16. Modified penoplasty for concealed penis in children.

    Science.gov (United States)

    Yang, Tianyou; Zhang, Liyu; Su, Cheng; Li, Zhongmin; Wen, Yingquan

    2013-09-01

    To report a modified penoplasty technique for concealed penis in children. Between January 2006 and June 2012, 201 cases of concealed penis were surgically repaired with modified penoplasty. The modified penoplasty technique consisted of 3 major steps: (1) degloved the penile skin and excised the inner prepuce, (2) advanced penoscrotal skin to cover penile shaft, and (3) fixed the penis base and reconstructed the penoscrotal angle. Two hundred one cases of concealed penis were enrolled in this study over a period of 6 years. Mean age at the time of surgery was 5.3 years (range 1-13 years) and mean operative time was 40 minutes (range 30-65minutes). All patients were routinely followed up at 1, 3, and 6 months after surgery. Most patients developed postoperative edema and were resolved within 1 month, whereas 20 cases developed prolonged postoperative edema, especially at the site of frenulum, which took 3 months to be resolved. Ten cases had retraction after surgery. No erection difficulties were recorded. Patients/parents reported better hygiene and improved visualization and accessibility of penis after surgery and were satisfied with the cosmetic outcome. The result of this study shows that the modified penoplasty technique is a simple, safe, and effective procedure for concealed penis with satisfied cosmetic outcome. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Modified Nance palatal button

    Directory of Open Access Journals (Sweden)

    Nitin Arora

    2015-01-01

    Full Text Available This paper describes modified Nance palatal button by which problems encountered in the palatal region around the acrylic button during space closure and molar distalization can be minimized.

  18. Intraocular pressure spikes after a sequential laser peripheral iridotomy for angle closure.

    Science.gov (United States)

    Lee, Tian-Loon; Yuxin Ng, Jamie; Nongpiur, Monisha E; Tan, Wai-Jia; Aung, Tin; Perera, Shamira A

    2014-12-01

    To determine the incidence of intraocular pressure (IOP) spikes within the first 30 minutes after sequential argon-Nd:YAG laser peripheral iridotomy (LPI) in patients with angle closure and to explore risk factors for their occurrence. A total of 428 consecutive eyes of 298 patients who had undergone LPI at the Singapore National Eye Centre between June 2011 and August 2011 were reviewed retrospectively. There were 238 primary angle closure suspect eyes, 85 primary angle closure eyes, 92 primary angle closure glaucoma eyes, and 13 acute primary angle closure (APAC) eyes. The pre-LPI IOP and post-LPI IOP, gonioscopic findings, medications, laser parameters, and the need for acute IOP-lowering treatment were recorded. The proportion of patients with a post-LPI IOP elevation ≥8 mm Hg was 10.7% (n=46) and those with a significant IOP spike of ≥30 mm Hg was 31 (7.2%). There were no significant differences between those with or without a post-LPI IOP elevation ≥8 mm Hg and those with or without a post-LPI IOP of ≥30 mm Hg, in terms of age, gender, race, total laser energy used, and seniority of the physician performing the procedure. Patients who experienced IOP spike ≥8 mm Hg were on fewer pre-LPI medications (P=0.009). On logistic regression, patients with APAC had a significantly higher probability of an IOP spike (P=0.003). The incidence of postsequential LPI IOP elevation ≥8 mm Hg was 10.7%. The primary diagnosis of APAC was a risk factor, and using preprocedure ocular hypotensives can potentially reduce their occurrence.

  19. Pediatric melanoma: incidence, treatment, and prognosis

    Directory of Open Access Journals (Sweden)

    Saiyed FK

    2017-04-01

    Full Text Available Faiez K Saiyed,1 Emma C Hamilton,1 Mary T Austin,1,2 1Department of Pediatric Surgery, McGovern Medical School, 2Department of Surgical Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA Abstract: The purpose of this review is to outline recent advancements in diagnosis, treatment, and prevention of pediatric melanoma. Despite the recent decline in incidence, it continues to be the deadliest form of skin cancer in children and adolescents. Pediatric melanoma presents differently from adult melanoma; thus, the traditional asymmetry, border irregularity, color variegation, diameter >6 mm, and evolution (ABCDE criteria have been modified to include features unique to pediatric melanoma (amelanotic, bleeding/bump, color uniformity, de novo/any diameter, evolution of mole. Surgical and medical management of pediatric melanoma continues to derive guidelines from adult melanoma treatment. However, more drug trials are being conducted to determine the specific impact of drug combinations on pediatric patients. Alongside medical and surgical treatment, prevention is a central component of battling the incidence, as ultraviolet (UV-related mutations play a central role in the vast majority of pediatric melanoma cases. Aggressive prevention measures targeting sun safety and tanning bed usage have shown positive sun-safety behavior trends, as well as the potential to decrease melanomas that manifest later in life. As research into the field of pediatric melanoma continues to expand, a prevention paradigm needs to continue on a community-wide level. Keywords: melanoma, pediatric, adolescent, childhood

  20. Decreasing incidence rates of bacteremia

    DEFF Research Database (Denmark)

    Nielsen, Stig Lønberg; Pedersen, C; Jensen, T G

    2014-01-01

    BACKGROUND: Numerous studies have shown that the incidence rate of bacteremia has been increasing over time. However, few studies have distinguished between community-acquired, healthcare-associated and nosocomial bacteremia. METHODS: We conducted a population-based study among adults with first......-acquired, 50.0 for healthcare-associated and 66.7 for nosocomial bacteremia. During 2000-2008, the overall incidence rate decreased by 23.3% from 254.1 to 198.8 (3.3% annually, p ...) and the incidence rate of nosocomial bacteremia decreased by 28.9% from 82.2 to 56.0 (4.2% annually, p

  1. Sex determination using facial linear dimensions and angles among Hausa population of Kano State, Nigeria

    Directory of Open Access Journals (Sweden)

    Lawan H. Adamu

    2016-12-01

    Full Text Available The aim of the study was to determine sexual dimorphism as well as to predict sex using facial linear dimensions and angles among Hausas of Kano state Nigeria. A total of 283 subjects comprising 147 males and 136 females age range 18–25 years participated. Photographs methods were used to capture the face. Independent sample t-test was used to test for sex differences in the variables. Binary logistic regression was applied to obtain a predicting equation (BLR model for sex. The predicted probabilities of BLR were analyzed using receiver operating characteristic curve. The results showed that all the facial linear dimensions showed significance sexual dimorphism except interocular distance, upper facial width, philtrum length, lower vermilion width, left and right orbital width. With regards to sex prediction, upper facial height was the single best predictor of sex with an accuracy of 76.2% and 24–33% contribution to the prediction. However, the percentage accuracy increased to 91% when six variables were pooled together in the equations. For facial angles, only nasion and aperture modified angle did not show significant gender differences. However, in the variables with significant sexual dimorphism only nasomental angle showed a significant level of sex prediction with an accuracy of 70.3%. In conclusion, sex discrimination using facial linear dimensions and angles was well established in this study. The sex of an individual of Hausa ethnic group can be determined using facial linear dimensions. Dispite sexual dimorphsm shown by facial angles, only nasomental angle was good discriminator of sex.

  2. Media actors' perceptions of their roles in reporting food incidents.

    Science.gov (United States)

    Wilson, Annabelle M; Henderson, Julie; Coveney, John; Meyer, Samantha B; Webb, Trevor; Calnan, Michael; Caraher, Martin; Lloyd, Sue; McCullum, Dean; Elliott, Anthony; Ward, Paul R

    2014-12-18

    Previous research has shown that the media can play a role in shaping consumer perceptions during a public health crisis. In order for public health professionals to communicate well-informed health information to the media, it is important that they understand how media view their role in transmitting public health information to consumers and decide what information to present. This paper reports the perceptions of media actors from three countries about their role in reporting information during a food incident. This information is used to present ideas and suggestions for public health professionals working with media during food incidents. Thirty three semi-structured interviews with media actors from Australia, New Zealand and the United Kingdom were conducted and analysed thematically. Media actors were recruited via purposive sampling using a sampling strategy, from a variety of formats including newspaper, television, radio and online. Media actors said that during a food incident, they play two roles. First, they play a role in communicating information to consumers by acting as a conduit for information between the public and the relevant authorities. Second, they play a role as investigators by acting as a public watchdog. Media actors are an important source of consumer information during food incidents. Public health professionals can work with media by actively approaching them with information about food incidents; promoting to media that as public health professionals, they are best placed to provide the facts about food incidents; and by providing angles for further investigation and directing media to relevant and correct information to inform such investigations. Public health professionals who adapt how they work with media are more likely to influence media to portray messages that fit what they would like the public to know and that are in line with public health recommendations and enable consumers to engage in safe and health promoting

  3. Biological response modifiers

    Energy Technology Data Exchange (ETDEWEB)

    Weller, R.E.

    1991-10-01

    Much of what used to be called immunotherapy is now included in the term biological response modifiers. Biological response modifiers (BRMs) are defined as those agents or approaches that modify the relationship between the tumor and host by modifying the host's biological response to tumor cells with resultant therapeutic effects.'' Most of the early work with BRMs centered around observations of spontaneous tumor regression and the association of tumor regression with concurrent bacterial infections. The BRM can modify the host response in the following ways: Increase the host's antitumor responses through augmentation and/or restoration of effector mechanisms or mediators of the host's defense or decrease the deleterious component by the host's reaction; Increase the host's defenses by the administration of natural biologics (or the synthetic derivatives thereof) as effectors or mediators of an antitumor response; Augment the host's response to modified tumor cells or vaccines, which might stimulate a greater response by the host or increase tumor-cell sensitivity to an existing response; Decrease the transformation and/or increase differentiation (maturation) of tumor cells; or Increase the ability of the host to tolerate damage by cytotoxic modalities of cancer treatment.

  4. Oblique incidence of semi-guided waves on rectangular slab waveguide discontinuities: A vectorial QUEP solver

    NARCIS (Netherlands)

    Hammer, Manfred

    2015-01-01

    The incidence of thin-film-guided, in-plane unguided waves at oblique angles on straight discontinuities of dielectric slab waveguides, an early problem of integrated optics, is being re-considered. The 3-D frequency domain Maxwell equations reduce to a parametrized inhomogeneous vectorial problem

  5. 75 FR 80735 - Special Conditions: Gulfstream Model GVI Airplane; High Incidence Protection

    Science.gov (United States)

    2010-12-23

    ... which an aerodynamic stall would occur. (c) Alpha-Limit--The maximum angle of attack at which the... decrease in stall speed, not more than zero thrust at the stall speed. (2) The airplane in other respects... the incidence at alpha limit as the longitudinal control reaches the stop is acceptable. Any reduction...

  6. Grazing incidence reflectivity and total electron yield effects in soft x-ray absorption spectroscopy

    NARCIS (Netherlands)

    Alders, D; Hibma, T; Sawatzky, G.A; Cheung, K.C.; van Dorssen, G.E.; Roper, M.D.; Padmore, H.A.; van der Laan, G.; Vogel, J; Sacchi, M.

    1997-01-01

    We report on a study of grazing incidence absorption and reflection spectra of NiO in the region of the Ni 2p edge. The aim is to evaluate the distortion of the near edge spectrum by the critical angle behavior of individual components within the spectrum. This can be used to improve the separation

  7. Contact angle and contact angle hysteresis measurements using the capillary bridge technique.

    Science.gov (United States)

    Restagno, Frédéric; Poulard, Christophe; Cohen, Céline; Vagharchakian, Laurianne; Léger, Liliane

    2009-09-15

    A new experimental technique is proposed to easily measure both advancing and receding contact angles of a liquid on a solid surface, with unprecedented accuracy. The technique is based on the analysis of the evolution of a capillary bridge formed between a liquid bath and a solid surface (which needs to be spherical) when the distance between the surface and the liquid bath is slowly varied. The feasibility of the technique is demonstrated using a low-energy perfluorinated surface with two different test liquids (water and hexadecane). A detailed description of both experimental procedures and computational modeling are given, allowing one to determine contact angle values. It is shown that the origin of the high accuracy of this technique relies on the fact that the contact angles are automatically averaged over the whole periphery of the contact. This method appears to be particularly adapted to the characterization of surfaces with very low contact angle hysteresis.

  8. Introduction to small-angle scattering

    International Nuclear Information System (INIS)

    Gilbert, E.

    2003-01-01

    Full text: Small angle neutron and X-ray scattering (SANS and SAXS) are ideal tools for studying the structure of materials in the size range between 10 and 1000 Angstrom. While imaging methods such as transmission electron microscopy (TEM) also have this capability, they provide images in real space, for instance individual grains in a nanocrystalline material. SANS and SAXS, on the other hand, provide (generally) a non-destructive method yielding structural information averaged over all grains with high statistical accuracy due to averaging over the whole sample volume. The use of neutrons and X-rays is also implicitly complementary due to their sensitivity to either nuclear or electron density respectively. This provides several further advantages over real-space techniques such as isotopic sensitivity and contrast variation. In this talk, I will provide an introduction to the technique with a minimum number of equations, emphasising what structural information may be obtained from small-angle scattering

  9. Fan Stagger Angle for Dirt Rejection

    Science.gov (United States)

    Gallagher, Edward J. (Inventor); Rose, Becky E. (Inventor); Brilliant, Lisa I. (Inventor)

    2015-01-01

    A gas turbine engine includes a spool, a turbine coupled to drive the spool, a propulsor coupled to be rotated about an axis by the turbine through the spool, and a gear assembly coupled between the propulsor and the spool such that rotation of the turbine drives the propulsor at a different speed than the spool. The propulsor includes a hub and a row of propulsor blades that extend from the hub. Each of the propulsor blades has a span between a root at the hub and a tip, and a chord between a leading edge and a trailing edge. The chord forms a stagger angle alpha with the axis, and the stagger angle alpha is less than 15 deg. at a position along the propulsor blade that is within an inboard 20% of the span.

  10. The small angle diffractometer SANS at PSI

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-11-01

    With the start-up of SINQ an instrument for small angle neutron scattering will be operational which compares well with the world`s largest and most powerful facilities of this kind. Following the classical principle of the D11-instrument of ILL, it is equipped with state-of-the-art components as are nowadays available, including options for further upgrading. Great emphasis was laid upon providing a flexible, universal multi-user facility which guarantees a comfortable and reliable operation. In the present paper, the principle layout of the instrument is presented, and the individual components are described in detail. The paper concludes with model application of small angle scattering to a system of dilute CuCo alloys which undergo a phase separation under thermal treatment, forming spherical Co-precipitates dispersed in a Cu-rich matrix. (author) 3 figs., 1 tab., 14 refs.

  11. Didactical Design Enrichment of Angle in Geometry

    Science.gov (United States)

    Setiadi, D. R.; Suryadi, D.; Mulyana, E.

    2017-09-01

    The underlying problem of this research is the lack of student’s competencies in understanding the concept of angle in geometry as the results of the teaching and learning pattern that only to receive the topic rather than to construct the topic and has not paid attention to the learning trajectory. The purpose of this research is to develop the didactical design of angle in space learning activity. The used research method is a method of qualitative research in the form of a didactical design research through three phases of analysis i.e. didactical situation analysis, metapedadidactical analysis, and retrospective analysis, which conducted in students from 10th grade at one of private schools in Bandung. Based on the results of research and discussion, the didactical design that has been made, is capable to change student’s learning habit and quite capable to develop student’s competencies although not optimal.

  12. Exclusive Backward-Angle Omega Meson Electroproduction

    Energy Technology Data Exchange (ETDEWEB)

    Wenliang, Li [Univ. of Regina, Regina, SK (Canada)

    2017-10-01

    Exclusive meson electroproduction at different squared four-momenta of the exchanged virtual photon, Q2 , and at different four-momentum transfers, t and u, can be used to probe QCD's transition from hadronic degrees of freedom at the long distance scale to quark-gluon degrees of freedom at the short distance scale. Backward-angle meson electroproduction was previously ignored, but is anticipated to offer complimentary information to conventional forward-angle meson electroproduction studies on nucleon structure. This work is a pioneering study of backward-angle ω cross sections through the exclusive 1H(e, e'p)ω reaction using the missing mass reconstruction technique. The extracted cross sections are separated into the transverse (T), longitudinal (L), and LT, TT interference terms. The analyzed data were part of experiment E01-004 (Fπ-2), which used 2.6-5.2 GeV electron beams and HMS+SOS spectrometers in Jefferson Lab Hall C. The primary objective was to detect coincidence π in the forward-angle, where the backward-angle omega events were fortuitously detected. The experiment has central Q2 values of 1.60 and 2.45 GeV2 , at W = 2.21 GeV. There was significant coverage in phi and epsilon, which allowed separation of σT,L,LT,TT . The data set has a unique u coverage of -u ~ 0, which corresponds to -t > 4 GeV2 . The separated σT result suggest a flat ~ 1/Q1.33±1.21 dependence, whereas sigma_L seems to hold a stronger 1/Q9.43±6.28 dependence. The σL/σT ratio indicate σT dominance at Q2 = 2.45 GeV2 at the ~90% confidence level. After translating the results into the -t space of the published CLAS data, our data show evidence of a backward-angle omega electroproduction peak at both Q2 settings. Previously, this phenomenon showing both forward and backward-angle peaks was only observed in the meson

  13. What's the angle: a study of the angle bisected in intraoral radiography.

    Science.gov (United States)

    Manson-Hing, L R

    1980-01-01

    Intraoral radiographs were made via the bisecting-the-angle technique on patients of different ages, sexes, and races. The tooth-film angles for various areas of the mouth were measured and found to be close to 30 degrees for all areas of the mouth except the mandibular posterior regions. The study was conducted to assist in quick positioning of the x-ray beam in difficult cases.

  14. Measurement of the angle alpha at BABAR

    Energy Technology Data Exchange (ETDEWEB)

    Perez, A.; /Orsay, LAL

    2009-06-25

    The authors present recent measurements of the CKM angle {alpha} using data collected by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the SLAC National Accelerator Laboratory, operating at the {Upsilon}(4S) resonance. They present constraints on {alpha} from B {yields} {pi}{pi}, B {yields} {rho}{rho} and B {yields} {rho}{pi} decays.

  15. Small-Angle Scattering on Magnetoferritin Nanoparticles

    Science.gov (United States)

    Balejčíková Petrenko, L., VI; Avdeev, MV; Garamus, VM; Almásy, L.; Kopčanský, P.

    2017-05-01

    Magnetoferritin is a synthetically prepared magnetic bio-complex, consisting of apoferritin shell and iron-based nanoparticles. Superparamagnetic behaviour, nanoscale size (about 12 nm) and biological origin allow to use magnetoferritin in various applications. In this report, we present a general overview about basic physicochemical properties of magnetoferritin, as determined by small-angle X-ray and neutron scattering experiments and some interesting references on their potential bio-applications.

  16. Neutron Reflectivity and Grazing Angle Diffraction

    OpenAIRE

    Ankner, J. F.; Majkrzak, C. F.; Satija, S. K.

    1993-01-01

    Over the last 10 years, neutron reflectivity has emerged as a powerful technique for the investigation of surface and interfacial phenomena in many different fields. In this paper, a short review of some of the work on neutron reflectivity and grazing-angle diffraction as well as a description of the current and planned neutron rcflectometers at NIST is presented. Specific examples of the characterization of magnetic, superconducting, and polymeric surfaces and interfaces are included.

  17. Neutron Reflectivity and Grazing Angle Diffraction.

    Science.gov (United States)

    Ankner, J F; Majkrzak, C F; Satija, S K

    1993-01-01

    Over the last 10 years, neutron reflectivity has emerged as a powerful technique for the investigation of surface and interfacial phenomena in many different fields. In this paper, a short review of some of the work on neutron reflectivity and grazing-angle diffraction as well as a description of the current and planned neutron rcflectometers at NIST is presented. Specific examples of the characterization of magnetic, superconducting, and polymeric surfaces and interfaces are included.

  18. Resonances and backward-angle scattering

    International Nuclear Information System (INIS)

    Stokstad, R.G.

    1978-01-01

    The strong enhancement of elastic scattering at large angles observed for systems such as α + 40 Ca and recently for 12 C + 28 Si and 16 O 28 Si was interpreted in terms of entrance channel resonances having a quasi-molecular character. Alternative explanations in terms of potential scattering were also presented. An overview is given of the experimental data and their interpretations. A consistent procedure for the evaluation of the experimental data is discussed. 50 references

  19. Study of the incident pion deflection in passing through atomic nucleus

    International Nuclear Information System (INIS)

    Strugalski, Z.; Pawlak, T.; Pluta, J.

    1982-01-01

    Pion-xenon nucleus collision events at 3.5 GeV/c momentum are studied in which the incident pion is deflected only, without particle production; the deflection is accompanied by emission of nucleons. The multiplicity of the protons emitted is a measure of the nuclear matter layer thickness passed by the pion. It can be concluded that: a) a definite simple relation exists between the pion deflection angle and the thickness of the nuclear matter layer traversed by this pion; b) the deflection angle of the incident pion increases in a definite manner with increasing the thickness of the nuclear matter layer traversed by this pion; c) the average kinetic energy, average longitudinal momentum and average transverse momentum of the protons emitted do not depend on the pion deflection angle

  20. Pair creation at large inherent angles

    International Nuclear Information System (INIS)

    Chen, P.; Tauchi, T.; Schroeder, D.V.

    1992-01-01

    In the next-generation linear colliders, the low-energy e + e - pairs created during the collision of high-energy e + e - beams would cause potential deleterious background problems to the detectors. At low collider energies, the pairs are made essentially by the incoherent process, where the pair is created by the interaction of beamstrahlung photons on the individual particles in the oncoming beam. This problem was first identified by Zolotarev, et al. At energies where the beamstrahlung parameter Υ lies approximately in the range 0.6 approx-lt Υ approx-lt 100, pair creation from the beamstrahlung photons is dominated by a coherent process, first noted by Chen. The seriousness of this pair creation problem lies in the transverse momenta that the pair particles carry when leaving the interaction point (IP) with large angles. Since the central issue is the transverse momentum for particles with large angles, the authors notice that there is another source for it. Namely, when the pair particles are created at low energies, the intrinsic angles of these pairs when produced may already be large. In this paper they reinvestigate the problem, following essentially the same equivalent photon approach, but with changes in specific details including the virtual photon spectrum. In addition, various assumptions are made more explicit. The formulas derived are then applied to the collider parameters designed by Palmer

  1. Multi-Angle Snowflake Camera Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Stuefer, Martin [Univ. of Alaska, Fairbanks, AK (United States); Bailey, J. [Univ. of Alaska, Fairbanks, AK (United States)

    2016-07-01

    The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

  2. Off-Angle Iris Correction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Thompson, Joseph T [ORNL; Karakaya, Mahmut [ORNL; Boehnen, Chris Bensing [ORNL

    2016-01-01

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not account for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.

  3. Studies in small angle scattering techniques

    International Nuclear Information System (INIS)

    Moellenbach, K.

    1980-03-01

    Small angle scattering of neutrons, X-rays and γ-rays are found among the spectroscopic methods developed in the recent years. Although these techniques differ from each other in many respects, e.g. radiation sources and technical equipment needed, their power to resolve physical phenomena and areas of application can be discussed in a general scheme. Selected examples are given illustrating the use of specific technical methods. Jahn-Teller driven structural phase transitions in Rare Earth zircons were studied with neutron scattering as well as small angle γ-ray diffraction. The study of neutron scattering from formations of magnetic domains in the Ising ferromagnet LiTbF 4 is a second example. Both these examples represent more than experimental test cases since the theoretical interpretations of the data obtained are discussed as well. As a last example the use of small angle scattering methods for the study of molecular biological samples is discussed. In particular the experimental procedures used in connection with scattering from aqueous solutions of proteins and protein complexes are given. (Auth.)

  4. Head flexion angle while using a smartphone.

    Science.gov (United States)

    Lee, Sojeong; Kang, Hwayeong; Shin, Gwanseob

    2015-01-01

    Repetitive or prolonged head flexion posture while using a smartphone is known as one of risk factors for pain symptoms in the neck. To quantitatively assess the amount and range of head flexion of smartphone users, head forward flexion angle was measured from 18 participants when they were conducing three common smartphone tasks (text messaging, web browsing, video watching) while sitting and standing in a laboratory setting. It was found that participants maintained head flexion of 33-45° (50th percentile angle) from vertical when using the smartphone. The head flexion angle was significantly larger (p smartphone, could be a main contributing factor to the occurrence of neck pain of heavy smartphone users. Practitioner Summary: In this laboratory study, the severity of head flexion of smartphone users was quantitatively evaluated when conducting text messaging, web browsing and video watching while sitting and standing. Study results indicate that text messaging while sitting caused the largest head flexion than that of other task conditions.

  5. Social relations, depressive symptoms, and incident type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Laursen, Karin Rosenkilde; Hulman, Adam; Witte, Daniel

    2017-01-01

    Aims We examined whether social relations are associated with the risk of developing type 2 diabetes mellitus (T2DM) and furthermore, whether social relations modify the association between depressive symptoms and incident T2DM. We hypothesized that the risk of developing T2DM would be lower...... for individuals with stronger social relations compared to those with weaker social relations, and that the association between depressive symptoms and incident T2DM would be attenuated for those with stronger social relations. Methods Non-diabetic participants (n = 7662) of the “English Longitudinal Study...... of developing T2DM; however, this effect is largely explained by known diabetes risk factors. No evidence was found that stronger social relations reduce the association between depressive symptoms and incident T2DM....

  6. Traffic incident management resource management.

    Science.gov (United States)

    2009-01-01

    The necessity of a multi-disciplinary approach involving law enforcement, fire and rescue, transportation, towing and recovery, and others has been well-recognized and integrated into incident management operations. This same multidisciplinar...

  7. Police Incident Blotter (30 Day)

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The 30 Day Police Blotter contains the most recent initial crime incident data, updated on a nightly basis. All data is reported at the block/intersection level,...

  8. Regional comparison of cancer incidence

    International Nuclear Information System (INIS)

    Obralic, N.; Gavrankapetanovic, F.; Dizdarevic, Z.; Duric, O.; Sisic, F.; Selak, I.; Balta, S.; Nakas, B.

    2004-01-01

    Background. Due to specific war and post-war situation in Balkan region, differences in the number, type, development, biological course, treatment of malignant tumours and its outcome are possible. In order to perceive the situation realistically, it is necessary to gather continuously exact data about malignant tumours and compare them with the data from other European and world countries.The aim of the study was to collect and analyse the data on cancer incidence in the region of Sarajevo city, which represents a symbol of difficult times in the recent past, and to compare it to the incidence in the neighbouring countries. Patients and methods. Data on all newly diagnosed cancer cases, permanent residents of Sarajevo Canton, in the years 1999 and 2000 were collected. Crude incidence rate has been calculated according to the years observed, gender and localizations of the disease The data were compared to the cancer registries of Slovenia and Croatia and were observed in the light of specific local situation. Results. The crude cancer incidence of all sites but skin was the highest in both years and by both genders in Croatia. The incidence of the most common tumours (lung and breast cancer) was similar in all three countries. The differences in the incidence between both genders in the Sarajevo canton were registered in laryngeal and urinary bladder cancer, as well as in bone and cartilage sarcoma. Cervical cancer had extremely high incidence and was high up on the incidence list in the Sarajevo canton, which correlates with the data in developing countries. The incidence of other tumours in the post-war period is reaching expected numbers. Conclusions. It is difficult to identify whether the war and post-war stress, irregular and insufficient nutrition during and after the siege of the city of Sarajevo or some other factor influenced the cancer incidence among exposed population. The prevalence of smoking in the whole region is extremely high, in Bosnia and

  9. Full-angle Negative Reflection with An Ultrathin Acoustic Gradient Metasurface: Floquet-Bloch Modes Perspective and Experimental Verification

    KAUST Repository

    Liu, Bingyi

    2017-07-01

    Metasurface with gradient phase response offers new alternative for steering the propagation of waves. Conventional Snell\\'s law has been revised by taking the contribution of local phase gradient into account. However, the requirement of momentum matching along the metasurface sets its nontrivial beam manipulation functionality within a limited-angle incidence. In this work, we theoretically and experimentally demonstrate that the acoustic gradient metasurface supports the negative reflection for full-angle incidence. The mode expansion theory is developed to help understand how the gradient metasurface tailors the incident beams, and the full-angle negative reflection occurs when the first negative order Floquet-Bloch mode dominates. The coiling-up space structures are utilized to build desired acoustic gradient metasurface and the full-angle negative reflections have been perfectly verified by experimental measurements. Our work offers the Floquet-Bloch modes perspective for qualitatively understanding the reflection behaviors of the acoustic gradient metasurface and enables a new degree of the acoustic wave manipulating.

  10. Asymptotics for incidence matrix classes

    OpenAIRE

    Cameron, Peter; Prellberg, Thomas; Stark, Dudley

    2005-01-01

    We define {\\em incidence matrices} to be zero-one matrices with no zero rows or columns. A classification of incidence matrices is considered for which conditions of symmetry by transposition, having no repeated rows/columns, or identification by permutation of rows/columns are imposed. We find asymptotics and relationships for the number of matrices with $n$ ones in these classes as $n\\to\\infty$.

  11. Incidence Handling and Response System

    OpenAIRE

    Kalbande, Prof. Dhananjay R.; Thampi, Dr. G. T.; Singh, Mr. Manish

    2009-01-01

    A computer network can be attacked in a number of ways. The security-related threats have become not only numerous but also diverse and they may also come in the form of blended attacks. It becomes difficult for any security system to block all types of attacks. This gives rise to the need of an incidence handling capability which is necessary for rapidly detecting incidents, minimizing loss and destruction, mitigating the weaknesses that were exploited and restoring the computing services. I...

  12. Cancer incidence in Spain, 2015.

    Science.gov (United States)

    Galceran, J; Ameijide, A; Carulla, M; Mateos, A; Quirós, J R; Rojas, D; Alemán, A; Torrella, A; Chico, M; Vicente, M; Díaz, J M; Larrañaga, N; Marcos-Gragera, R; Sánchez, M J; Perucha, J; Franch, P; Navarro, C; Ardanaz, E; Bigorra, J; Rodrigo, P; Bonet, R Peris

    2017-07-01

    Periodic cancer incidence estimates of Spain from all existing population-based cancer registries at any given time are required. The objective of this study was to present the current situation of cancer incidence in Spain. The Spanish Network of Cancer Registries (REDECAN) estimated the numbers of new cancer cases occurred in Spain in 2015 by applying the incidence-mortality ratios method. In the calculus, incidence data from population-based cancer registries and mortality data of all Spain were used. In 2015, nearly a quarter of a million new invasive cancer cases were diagnosed in Spain, almost 149,000 in men (60.0%) and 99,000 in women. Globally, the five most common cancers were those of colon-rectum, prostate, lung, breast and urinary bladder. By gender, the four most common cancers in men were those of prostate (22.4%), colon-rectum (16.6%), lung (15.1%) and urinary bladder (11.7%). In women, the most common ones were those of breast (28.0%), colon-rectum (16.9%), corpus uteri (6.2%) and lung (6.0%). In recent years, cancer incidence in men seems to have stabilized due to the fact that the decrease in tobacco-related cancers compensates for the increase in other types of cancer like those of colon and prostate. In women, despite the stabilization of breast cancer incidence, increased incidence is due, above all, to the rise of colorectal and tobacco-related cancers. To reduce these incident cancer cases, improvement of smoking control policies and extension of colorectal cancer screening should be the two priorities in cancer prevention for the next years.

  13. [Morphology of the Meibomian lipid film. Results of Brewster angle microscopy].

    Science.gov (United States)

    Kaercher, T; Hönig, D; Möbius, D; Welt, R

    1995-02-01

    Meibomian lipid layers were studied in the anterior mirror area by reflecting microscopy and interference microscopy. Using these techniques, it was not possible to correlate the biophysical and morphological data. Brewster angle microscopy provides direct observation of the spread Meibomian lipid layer with simultaneous registration of the surface pressure. It is based on the fact that He-Ne laser light, which is incident at a water surface under the Brewster angle, does not reflect visible light. After spreading of a lipid film, the angle of the incident light beam varies, causing reflection of light. The Meibomian lipid layer was studied in a Langmuir-type trough. At 5.0 mN/m the lipid layers are homogeneous and mobile, consisting of areas of higher and lower reflectivity. In patients with meibomitis the films are inhomogeneous and immobile. The thickness of the areas of lower reflectivity is 2 nm, the high reflectivity lipids are 8-10 nm thick. According to these results, Meibomian gland secretion can form monolayers under in vitro conditions.

  14. Research on recognition of ramp angle based on transducer

    Directory of Open Access Journals (Sweden)

    Wenhao GU

    2015-12-01

    Full Text Available Focusing on the recognition of ramp angle, the relationship between the signal of vehicle transducer and real ramp angle is studied. The force change of vehicle on the ramp, and the relationship between the body tilt angle and front and rear suspension scale is discussed. According to the suspension and tire deformation, error angle of the ramp angle is deduced. A mathematical model is established with Matlab/Simulink and used for simulation to generate error curve of ramp angle. The results show that the error angle increases with the increasing of the ramp angle, and the limit value can reach 6.5%, while the identification method can effectively eliminate this error, and enhance the accuracy of ramp angle recognition.

  15. The effect of beam angle in abrasive-waterjet machining

    International Nuclear Information System (INIS)

    Hashish, M.

    1989-01-01

    In the machining of materials, abrasive-waterjets are typically applied at a 90-degree angle to the surface of the workpiece. This paper presents results and observations on machining with abrasive-waterjets at angles other than 90 degrees. Previous visualization studies of the cutting process in transparent materials has shown that there are optimal angles for maximum depth of cut and kerf depth uniformity. Here, observations on the effect of angle in machining applications, such as turning, milling. linear cutting, and drilling, are addressed. The effects of variations in both the impact angle and the rake angle are investigated. Results indicate that the volume removal rate is significantly affected by these angles and that surface finish can be improved by angling the jet. However, shallow angle drilling of small holes in laminated or ceramic-coated materials requires further investigation

  16. Cyber Incidents Involving Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Robert J. Turk

    2005-10-01

    The Analysis Function of the US-CERT Control Systems Security Center (CSSC) at the Idaho National Laboratory (INL) has prepared this report to document cyber security incidents for use by the CSSC. The description and analysis of incidents reported herein support three CSSC tasks: establishing a business case; increasing security awareness and private and corporate participation related to enhanced cyber security of control systems; and providing informational material to support model development and prioritize activities for CSSC. The stated mission of CSSC is to reduce vulnerability of critical infrastructure to cyber attack on control systems. As stated in the Incident Management Tool Requirements (August 2005) ''Vulnerability reduction is promoted by risk analysis that tracks actual risk, emphasizes high risk, determines risk reduction as a function of countermeasures, tracks increase of risk due to external influence, and measures success of the vulnerability reduction program''. Process control and Supervisory Control and Data Acquisition (SCADA) systems, with their reliance on proprietary networks and hardware, have long been considered immune to the network attacks that have wreaked so much havoc on corporate information systems. New research indicates this confidence is misplaced--the move to open standards such as Ethernet, Transmission Control Protocol/Internet Protocol, and Web technologies is allowing hackers to take advantage of the control industry's unawareness. Much of the available information about cyber incidents represents a characterization as opposed to an analysis of events. The lack of good analyses reflects an overall weakness in reporting requirements as well as the fact that to date there have been very few serious cyber attacks on control systems. Most companies prefer not to share cyber attack incident data because of potential financial repercussions. Uniform reporting requirements will do much to make this

  17. Small angle elastic scattering of protons off of spinless nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Ling, A.G.

    1988-07-01

    Elastic differential cross sections and analyzing powers for 800 MeV protons incident on /sup 12/C, /sup 40/Ca, and /sup 208/Pb in the momentum transfer range 20 MeV/c < q < 130 MeV/c have been measured. The data was taken with the High Resolution Spectrometer (HRS) at the Los Alamos Meson Physics Facility. Special delay-line drift chambers with dead regions for the beam to pass through them were used to obtain the data. Through the interference of the Coulomb and nuclear contributions to the differential cross section in the small angle region, the ratio of the real to imaginary part of the forward nuclear amplitude ..cap alpha../sub n/(0) = Ref/sub n/(0)/Imf/sub n/(0) is extracted. The importance of knowing this quantity at lower energies in order to study the differences between relativistic and non-relativistic scattering theories is discussed. 130 refs., 60 figs., 12 tabs.

  18. On-ground characterization of the IXPE polarization angle knowledge

    Science.gov (United States)

    Evangelista, Y.

    2017-08-01

    The Imaging X-ray Polarimetry Explorer (IXPE) has been recently selected for development as part of NASA's Small Explorer program (SMEX), with a launch date in 2021. Developed in a collaboration between NASA and the Italian Space Agency (ASI), IXPE will perform groundbreaking measurements of imaging polarization in X-rays for a number of different classes of sources including isolated and accreting neutron stars, pulsar wind nebulae, stellar and supermassive black holes. Combining 30 arcsec (HPD) grazing-incidence X-ray optics with the polarization-sensitive Gas Pixel Detectors (GPDs), IXPE will provide two-orders of magnitude improvement in sensitivity over the past flown instruments. The IXPE requested precision on the measurement of the polarization angle (better than 0.2 degrees at instrument level) poses strict constraints on the detector unit (DU) mechanical design and requires the implementation of a specific alignment and measurement strategy to meet the scientific requirements. In this paper we describe the design solutions that will be implemented in the DU flight models as well as a step-by-step metrology procedure that will ensure the fulfillment of the scientific requirement.

  19. [Measurement of the lumbosacral angle and its clinical significance].

    Science.gov (United States)

    Bene, E

    1981-01-01

    The author reports about the result of a series of investigations and tests concerning the angle of the L-S vertebral column. Different factors influencing the values of L-S angle are analyzed. The clinical importance of the respective angles is small, the statics of the L-S transition is determined by all angles together. The reduced L-S angle cannot be considered as an aetiological factor of the spondylolysthesis. The pathological angle values as well as the positions play a role in the induction of the discopathy

  20. Measurement of large angle Rayleigh scattering cross sections for 39.5, 40.1 and 45.4keV photons in elements with 26 ≤ Z ≤ 83.

    Science.gov (United States)

    Upmanyu, Arun; Singh, Gurjot; Duggal, Heena; Kainth, H S; Bhalla, Atul; Kumar, Sanjeev

    2017-10-01

    The present work reports Rayleigh scattering cross section measurements for the 39.5keV (Sm- Kα 2 ), 40.1keV (Sm-Kα 1 ) and 45.4keV (Sm-Kβ 1,3 ) X-ray photons in 35 elements with 26 ≤ Z ≤ 83 at backward angle of 139°. The scattering measurements were performed in reflection mode geometrical set up involving a secondary photon source consisting of Samarium ( 62 Sm) target excited by the 59.54keV γ-rays from the 241 Am radioactive source. The scattered photons were detected using a low energy germanium (LEGe) detector. The product of detector efficiency, intensity of incident photons and other geometrical factors were determined by measuring the K X-ray yields from targets with 47 ≤ Z ≤ 59 and knowledge of the respective K X-ray fluorescence cross sections. The measured cross sections are compared with the theoretical cross sections based on the modified form factor (MF) formalisms and the second-order S-matrix approach. The experimental results demonstrate large deviations from the MF values for the elements with K shell binding energy (B K ) in vicinity of the incident photon energy (E in ), which smooth out with inclusion of the anomalous scattering factors (ASFs). The S-matrix values, in general, agree with the measured cross sections for all the elements under investigation. Copyright © 2017 Elsevier Ltd. All rights reserved.