WorldWideScience

Sample records for inch diameter solid

  1. Test Report for MSFC Test No. 83-2: Pressure scaled water impact test of a 12.5 inch diameter model of the Space Shuttle solid rocket booster filament wound case and external TVC PCD

    Science.gov (United States)

    1983-01-01

    Water impact tests using a 12.5 inch diameter model representing a 8.56 percent scale of the Space Shuttle Solid Rocket Booster configuration were conducted. The two primary objectives of this SRB scale model water impact test program were: 1. Obtain cavity collapse applied pressure distributions for the 8.56 percent rigid body scale model FWC pressure magnitudes as a function of full-scale initial impact conditions at vertical velocities from 65 to 85 ft/sec, horizontal velocities from 0 to 45 ft/sec, and angles from -10 to +10 degrees. 2. Obtain rigid body applied pressures on the TVC pod and aft skirt internal stiffener rings at initial impact and cavity collapse loading events. In addition, nozzle loads were measured. Full scale vertical velocities of 65 to 85 ft/sec, horizontal velocities of 0 to 45 ft/sec, and impact angles from -10 to +10 degrees simulated.

  2. Seismic fragility test of a 6-inch diameter pipe system

    International Nuclear Information System (INIS)

    Chen, W.P.; Onesto, A.T.; DeVita, V.

    1987-02-01

    This report contains the test results and assessments of seismic fragility tests performed on a 6-inch diameter piping system. The test was funded by the US Nuclear Regulatory Commission (NRC) and conducted by ETEC. The objective of the test was to investigate the ability of a representative nuclear piping system to withstand high level dynamic seismic and other loadings. Levels of loadings achieved during seismic testing were 20 to 30 times larger than normal elastic design evaluations to ASME Level D limits would permit. Based on failure data obtained during seismic and other dynamic testing, it was concluded that nuclear piping systems are inherently able to withstand much larger dynamic seismic loadings than permitted by current design practice criteria or predicted by the probabilistic risk assessment (PRA) methods and several proposed nonlinear methods of failure analysis

  3. Interim results: fines recycle testing using the 4-inch diameter primary graphite burner

    International Nuclear Information System (INIS)

    Palmer, W.B.

    1975-05-01

    The results of twenty-two HTGR primary burner runs in which graphite fines were recycled pneumatically to the 4-inch diameter pilot-plant primary fluidized-bed burner are described. The result of the tests showed that zero fines accumulation can easily be achieved while operating at plant equivalent burn rates. (U.S.)

  4. Fabrication of 0.5-inch diameter FBR mixed oxide fuel pellets

    International Nuclear Information System (INIS)

    Rasmussen, D.E.; Benecke, M.W.; McCord, R.B.

    1979-01-01

    Large diameter (0.535 inch) mixed oxide fuel pellets for Fast Breeder Reactor application were successfully fabricated by the cold-press-and-sinter technique. Enriched UO 2 , PuO 2 -UO 2 , and PuO 2 -ThO 2 compositions were fabricated into nominally 90% theoretical density pellets for the UO 2 and PuO 2 -UO 2 compositions, and 88% and 93% T.D. for the PuO 2 -ThO 2 compositions. Some processing adjustments were required to achieve satisfactory pellet quality and density. Furnace heating rate was reduced from 200 to 50 0 C/h for the organic binder burnout cycle for the large, 0.535-inch diameter pellets to eliminate pellet cracking during sintering. Additional preslugging steps and die wall lubrication during pressing were used to eliminate pressing cracks in the PuO 2 -ThO 2 pellets

  5. Stand Development 25 Years after a 9.0-inch Diameter-Limit First Cutting In Appalachian Hardwoods

    Science.gov (United States)

    H. Clay Smith; N. I. Lamson

    1977-01-01

    This report is a case history of stand development 25 years after a 9.0-inch diameter-limit cutting in a primarily second growth 40- to 45-year-old Appalachian hardwood stand. Some old residual trees from the early 1900 logging era were scattered throughout the stand. In 1950, a 9.0-inch diameter-limit cutting removed 8,650 board feet per acre and reduced the basal...

  6. Project W320 52-inch diameter equipment container load test: Test report

    International Nuclear Information System (INIS)

    Bellomy, J.R.

    1995-01-01

    This test report summarizes testing activities and documents the results of the load tests performed on-site and off-site to structural qualify the 52-inch equipment containers designed and fabricated under Project W-320

  7. Production and cost of harvesting, processing, and transporting small-diameter (< 5 inches) trees for energy

    Science.gov (United States)

    Fei Pan; Han-Sup Han; Leonard R. Johnson; William J. Elliot

    2008-01-01

    Dense, small-diameter stands generally require thinning from below to improve fire-tolerance. The resulting forest biomass can be used for energy production. The cost of harvesting, processing, and transporting small-diameter trees often exceeds revenues due to high costs associated with harvesting and transportation and low market values for forest biomass....

  8. Vertical Force-deflection Characteristics of a Pair of 56-inch-diameter Aircraft Tires from Static and Drop Tests with and Without Prerotation

    Science.gov (United States)

    Smiley, Robert F; Horne, Walter B

    1957-01-01

    The vertical force-deflection characteristics were experimentally determined for a pair of 56-inch-diameter tires under static and drop-test conditions with and without prerotation. For increasing force, the tires were found to be least stiff for static tests, almost the same as for the static case for prerotation drop tests as long as the tires remain rotating, and appreciably stiffer for drop tests without prerotation.

  9. The effects of Earth's magnetic field on 3-inch diameter photomultipliers used in KM3NeT neutrino telescope

    Science.gov (United States)

    Giordano, V.; Aiello, S.; Leonora, E.; Randazzo, N.

    2016-04-01

    The KM3NeT neutrino telescope will be the largest underwater neutrino telescope and will be located in the abyss of the Mediterranean Sea. In neutrino telescopes the key element of the detector is the optical module and for KM3NeT it consists of 31 PMTs stored inside a transparent pressure-resistant glass sphere of 17-inch that serves as mechanical protection while ensuring good light transmission. Since the PMTs installed into an underwater neutrino telescope can change their orientation because of movements of the detector structure due to sea currents, the influence of Earth's magnetic field has been investigated. Magnetic shielding by means of a mu-metal cage is used to reduce magnetic effects and to make the response of the PMT sufficiently orientation independent. In order to quantify the effect on magnetic field, we compared measurements on variation of gain, transit time spread and detection efficiency for a 3-inch PMT in shielded and unshielded condition at 3 PMT inclinations. Data shows that variations are sufficiently low especially for timing properties.

  10. Experimental and numerical approach on fracture behaviour of four inches diameter carbon-manganese cracked welded pipes in four point bending

    International Nuclear Information System (INIS)

    Semete, P.; Faidy, C.; Lautier, J.L.

    2001-01-01

    EDF has conducted a research programme to demonstrate the fracture resistance of carbon-manganese welded pipes. The main task of this programme consisted of testing three four inches diameter (114.3 mm O.D.) thin welded pipes (8.56 mm thick) which are representative of those of the sites. The three pipes were loaded under four point bending at a quasi-static rate at -20 C till their maximum bending moment was reached. This paper presents the experimental results, finite element calculations and their comparison with the simplified fracture assessment method of the RSE-M Code. (author)

  11. Ductile fracture behavior of 6-inch diameter type 304 stainless steel and STS 42 carbon steel piping containing a through-wall or part-through crack

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Ohba, Toshihiro; Kawamura, Takaichi; Miyazono, Shohachiro; Kaneko, Tadashi; Yokoyama, Norio.

    1986-05-01

    The double ended guillotine break philosophy in the design base accident of the nuclear power plant is considered to be overly conservative from the view point of piping design. Through the past experiences and developments of the fabrication, inspection, and operation of nuclear power plants, it has been recognized that the Leak-Before-Break (LBB) concept can be justified in the LWR pressure boundary pipings. In order to verify the LBB concept, extensive experimental and theoretical works are being conducted in many countries. Furthermore, a revised piping design standard, in which LBB concept is introduced, is under preparation in Japan, U.S.A., and European countries. At JAERI, a research program to investigate the unstable ductile fracture behavior of LWR piping under bending load has been carried out as a part of the LBB verification researches since 1983. This report summarizes the result of the ductile fracture tests conducted at room temperature in 1983 and 84. The 6-inch diameter pipes of type 304 stainless steel and STS 42 carbon steel pipe with a through-wall or part-through crack were tested under bending load with low or high compliance condition at room temperature. Pipe fracture data were obtained from the test as regards to load- displacement curve, crack extension, net section stress, J-resistance curve, and so on. Besides, the influence of the compliance on the fracture behavior was examined. Discussions are performed on the ductile pipe fracture criterion, flaw evaluation criterion, and LBB evaluation method. (author)

  12. Pressure scaled water impact test of a 12.5 inch diameter model of the Space Shuttle solid rocket booster

    Science.gov (United States)

    1982-01-01

    A total of 59 tail first drops were made. Model entry conditions simulated full scale vertical velocities of approximately 75 to 110 ft/sec with horizontal velocities up to 45 ft/sec and impact angles to + or - 10 deg. These tests were conducted at scaled atmospheric pressures (1.26 psia or 65 mm.Hg). The model, test program, test facility, test equipment, instrumentation system, data reduction procedures, and test results are described.

  13. Replacement of 13 valves by using an isolation plug in the 20 inches diameter main offshore gas pipeline at Cantarell oil field, Campeche Bay, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Carvahal Reyes, Jorge Omar; Ulloa Ochoa, Carlos Manuel [PEMEX, Exploracion y Produccion, MX (Mexico)

    2009-12-19

    In 2002 we changed 13 valves on deck of one gas production platform called Nohoch-A-Enlace at Cantarell Offshore Oil Field. The 20'' diameter gas pipeline and 200 km of length, transport and deliver gas for others production platforms in the Gas Lift System, So 2 millions of oil barrels per day depends of the operation of this gas pipeline but there was 13 valves on pig traps to be changed after 20 years of service to high pressure (64 to 63 kg/cm{sup 2}). We could not stop the operation of this pipeline and some little gas leaks were eliminated in some parts of the valves. This pipeline has two risers so the gas can be injected by two sides of the ring of 20 Km. So we found the proper technology in order to isolate one riser nad change 8 valves and the isolate the other and change the 5, and the gas lift system never stop during the plug and maintenance operations on platform. In the first isolation plug operation this tool run 20 mts inside the riser and was actionated and resists 65 Kg/cm{sup 2} of gas pressure during 44 hours so we changed 8 valves: 2 of 20'', 2 of 10'', 3 of 4'' and 1 of 8'' diameter. In the second isolation the plug run 30 mts inside the second risers and resist 64 Kg/cm{sup 2} of gas during 46 hours and we changed 5 valves of 20'' diameter. In the paper I will describe all the details of this successful operations and procedures. Also the aspects of Health, Security and Environment that we prepared one year before this operations at platform. Pemex save almost 2.5 millions of dollars because the gas lift system never stop and all valves were changed and now we can run cleaning and inspection tools inside the full ring. We used the first isolation plug in Latin America and we want to share this experience to all the pipeline operators in the world as a good practice in pipeline maintenance using plugging technology in the main and large pipelines of high pressure. (author)

  14. Effect of catalyst diameter on vapour-liquid-solid growth of GaAs nanowires

    Energy Technology Data Exchange (ETDEWEB)

    O' Dowd, B. J., E-mail: odowdbj@tcd.ie; Shvets, I. V. [CRANN, School of Physics, Trinity College, the University of Dublin, Dublin D2 (Ireland); Wojtowicz, T.; Kolkovsky, V.; Wojciechowski, T.; Zgirski, M. [Institute of Physics, Polish Academy of Sciences, Warsaw 02-668 (Poland); Rouvimov, S. [Notre Dame Integrated Imaging Facility (NDIIF), University of Notre Dame, Notre Dame, Indiana 46556 (United States); Liu, X.; Pimpinella, R.; Dobrowolska, M.; Furdyna, J. [Department of Physics, University of Notre Dame, Notre Dame, Indiana 46556 (United States)

    2014-08-14

    GaAs nanowires were grown on (111)B GaAs substrates using the vapour-liquid-solid mechanism. The Au/Pt nanodots used to catalyse wire growth were defined lithographically and had varying diameter and separation. An in-depth statistical analysis of the resulting nanowires, which had a cone-like shape, was carried out. This revealed that there were two categories of nanowire present, with differing height and tapering angle. The bimodal nature of wire shape was found to depend critically on the diameter of the Au-Ga droplet atop the nanowire. Transmission electron microscopy analysis also revealed that the density of stacking faults in the wires varied considerably between the two categories of wire. It is believed that the cause of the distinction in terms of shape and crystal structure is related to the contact angle between the droplet and the solid-liquid interface. The dependency of droplet diameter on contact angle is likely related to line-tension, which is a correction to Young's equation for the contact angle of a droplet upon a surface. The fact that contact angle may influence resulting wire structure and shape has important implications for the planning of growth conditions and the preparation of wires for use in proposed devices.

  15. POSSIBILITIES OF THE EFFICIENT SOLID-LIQUlD SEPARATION IN THE HYDROCYCLONE OF 25 mm DIAMETER

    Directory of Open Access Journals (Sweden)

    Branko Salopek

    1995-12-01

    Full Text Available The hydrocyclone, of 25 mm diameter has been tested on the laboratory hydrocyclonic device. There have been varied the values of relationship between Du/Do the concentration of feed suspension and the greatness of pressure. With thc suspension of fine grindeed limestone and water there have been examined 36 combinations of various values for the mentioned variables, The optimal efficiency of the liquid in overflow has been achieved hy the relationship Du/Do=0.73 ranging from 70...80 % with the concentration of the solids in overflow from 0.3..1.5 % and cut size of 0.004...0.006 mm. There have been shown three schemes of separation of drilling fluids proposing the application of multicyclones instead of centrifuges in the final phase of cleaning the fluids

  16. 2 inch diameter single crystal growth and scintillation properties of Ce:Gd.sub.3./sub.Al.sub.2./sub.Ga.sub.3./sub.O.sub.12./sub..

    Czech Academy of Sciences Publication Activity Database

    Kamada, K.; Yanagida, T.; Endo, T.; Tsutumi, K.; Usuki, Y.; Nikl, Martin; Fujimoto, Y.; Fukabori, A.; Yoshikawa, A.

    2012-01-01

    Roč. 352, č. 1 (2012), s. 88-90 ISSN 0022-0248 Grant - others:AV ČR(CZ) M100100910 Institutional research plan: CEZ:AV0Z10100521 Keywords : Czochralski method * oxides * scintillator materials Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.552, year: 2012

  17. Ten inch Planar Optic Display

    Energy Technology Data Exchange (ETDEWEB)

    Beiser, L. [Beiser (Leo) Inc., Flushing, NY (United States); Veligdan, J. [Brookhaven National Lab., Upton, NY (United States)

    1996-04-01

    A Planar Optic Display (POD) is being built and tested for suitability as a high brightness replacement for the cathode ray tube, (CRT). The POD display technology utilizes a laminated optical waveguide structure which allows a projection type of display to be constructed in a thin (I to 2 inch) housing. Inherent in the optical waveguide is a black cladding matrix which gives the display a black appearance leading to very high contrast. A Digital Micromirror Device, (DMD) from Texas Instruments is used to create video images in conjunction with a 100 milliwatt green solid state laser. An anamorphic optical system is used to inject light into the POD to form a stigmatic image. In addition to the design of the POD screen, we discuss: image formation, image projection, and optical design constraints.

  18. 10-inch planar optic display

    Science.gov (United States)

    Beiser, Leo; Veligdan, James T.

    1996-05-01

    A planar optic display (POD) is being built and tested for suitability as a high brightness replacement for the cathode ray tube, (CRT). The POD display technology utilizes a laminated optical waveguide structure which allows a projection type of display to be constructed in a thin (1 to 2 inch) housing. Inherent in the optical waveguide is a black cladding matrix which gives the display a black appearance leading to very high contrast. A digital micromirror device, (DMD) from Texas Instruments is used to create video images in conjunction with a 100 milliwatt green solid state laser. An anamorphic optical system is used to inject light into the POD to form a stigmatic image. In addition to the design of the POD screen, we discuss: image formation, image projection, and optical design constraints.

  19. Slowing single-stranded DNA translocation through a solid-state nanopore by decreasing the nanopore diameter.

    Science.gov (United States)

    Akahori, Rena; Haga, Takanobu; Hatano, Toshiyuki; Yanagi, Itaru; Ohura, Takeshi; Hamamura, Hirotaka; Iwasaki, Tomio; Yokoi, Takahide; Anazawa, Takashi

    2014-07-11

    To slow the translocation of single-stranded DNA (ssDNA) through a solid-state nanopore, a nanopore was narrowed, and the effect of the narrowing on the DNA translocation speed was investigated. In order to accurately measure the speed, long (5.3 kb) ssDNA (namely, ss-poly(dA)) with uniform length (±0.4 kb) was synthesized. The diameters of nanopores fabricated by a transmission electron microscope were controlled by atomic-layer deposition. Reducing the nanopore diameter from 4.5 to 2.3 nm slowed down the translocation of ssDNA by more than 16 times (to 0.18 μs base(-1)) when 300 mV was applied across the nanopore. It is speculated that the interaction between the nanopore and the ssDNA dominates the translocation speed. Unexpectedly, the translocation speed of ssDNA through the 4.5 nm nanopore is more than two orders of magnitude higher than that of double-stranded DNA (dsDNA) through a nanopore of almost the same size. The cause of such a faster translocation of ssDNA can be explained by the weaker drag force inside the nanopore. Moreover, the measured translocation speeds of ssDNA and dsDNA agree well with those calculated by molecular-dynamics (MD) simulation. The MD simulation predicted that reducing the nanopore diameter to almost the same as that of ssDNA (i.e. 1.4 nm) decreases the translocation speed (to 1.4 μs base(-1)). Narrowing the nanopore is thus an effective approach for accomplishing nanopore DNA sequencing.

  20. Orthopedic stretcher with average-sized person can pass through 18-inch opening

    Science.gov (United States)

    Lothschuetz, F. X.

    1966-01-01

    Modified Robinson stretcher for vertical lifting and carrying, will pass through an opening 18 inches in diameter, while containing a person of average height and weight. A subject 6 feet tall and weighing 200 pounds was lowered and raised out of an 18 inch diameter opening in a tank to test the stretcher.

  1. 8-inch IBM floppy disk

    CERN Multimedia

    1971-01-01

    The 8-inch floppy disk was a magnetic storage disk for the data introduced commercially by IBM in 1971. It was designed by an IBM team as an inexpensive way to load data into the IBM System / 370. Plus it was a read-only bare disk containing 80 KB of data. The first read-write version was introduced in 1972 by Memorex and could contain 175 KB on 50 tracks (with 8 sectors per track). Other improvements have led to various coatings and increased capacities. Finally, it was surpassed by the mini diskette of 5.25 inches introduced in 1976.

  2. Test procedure for the Master-Lee and the modified Champion four inch hydraulic cutters

    International Nuclear Information System (INIS)

    Crystal, J.B.

    1995-01-01

    The Master-Lee and the modified Champion 4 Inch hydraulic cutters are being retested to gather and document information related to the following: determine if the Master-Lee cutters will cut the trunnions of an Aluminum fuel canister and a Stainless Steel fuel canister; determine if the Master-Lee cutters will cut 1 1/2 inch diameter fire hose; determine if the modified Champion 4 inch blade will cut sections of piping; and determine the effectiveness of the centering device for the Champion 4 Inch cutters. Determining the limitations of the hydraulic cutter will aid in the process of debris removal in the K-Basin. Based on a previous test, the cutters were returned to the manufacturer for modifications. The modifications to the Champion 4 Inch Cutter and further testing of the Master-Lee Cutter are the subjects of these feature tests

  3. Nuclear criticality safety calculational analysis for small-diameter containers

    International Nuclear Information System (INIS)

    LeTellier, M.S.; Smallwood, D.J.; Henkel, J.A.

    1995-11-01

    This report documents calculations performed to establish a technical basis for the nuclear criticality safety of favorable geometry containers, sometimes referred to as 5-inch containers, in use at the Portsmouth Gaseous Diffusion Plant. A list of containers currently used in the plant is shown in Table 1.0-1. These containers are currently used throughout the plant with no mass limits. The use of containers with geometries or material types other than those addressed in this evaluation must be bounded by this analysis or have an additional analysis performed. The following five basic container geometries were modeled and bound all container geometries in Table 1.0-1: (1) 4.32-inch-diameter by 50-inch-high polyethylene bottle; (2) 5.0-inch-diameter by 24-inch-high polyethylene bottle; (3) 5.25-inch-diameter by 24-inch-high steel can (open-quotes F-canclose quotes); (4) 5.25-inch-diameter by 15-inch-high steel can (open-quotes Z-canclose quotes); and (5) 5.0-inch-diameter by 9-inch-high polybottle (open-quotes CO-4close quotes). Each container type is evaluated using five basic reflection and interaction models that include single containers and multiple containers in normal and in credible abnormal conditions. The uranium materials evaluated are UO 2 F 2 +H 2 O and UF 4 +oil materials at 100% and 10% enrichments and U 3 O 8 , and H 2 O at 100% enrichment. The design basis safe criticality limit for the Portsmouth facility is k eff + 2σ < 0.95. The KENO study results may be used as the basis for evaluating general use of these containers in the plant

  4. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  5. Numerical Simulation Analysis of Five-Step Variable-Diameter Pipe with Solid-Liquid Two-Phase Abrasive Flow Polishing

    Science.gov (United States)

    Li, Junye; Zhang, Hengfu; Wu, Guiling; Hu, Jinglei; Liu, Yang; Sun, Zhihui

    2018-01-01

    In many areas of precision machining abrasive flow polishing technology has an important role. In order to study the influence of abrasive flow on the polishing effect of variable diameter parts, the fifth step variable diameter tube was taken as the research object to analyze the dynamic pressure and turbulent kinetic energy distribution of inlet velocity on the fifth-order variable diameter tube influences. Through comparative analysis, the abrasive flow polished variable diameter pipe parts have very effective and significant polishing effect and the higher the inlet speed, the more significant the polishing effect.

  6. Ultrasonography-guided Fine-needle Aspiration for Solid Thyroid Nodules Less than 5 mm in the Largest Diameter: Comparison in Diagnostic Adequacy and Accuracy According to Nodule Size

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang Hee; Kim, Dong Wook; Baek, Seung Hun [Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2012-03-15

    This study assessed the adequacy and accuracy of ultrasonography (US)-guided fine-needle aspiration (US-FNA) of solid thyroid nodules, less than 5 mm in maximum diameter. From January to December 2009, US-FNA was performed for small solid thyroid nodules in 201 patients. Each thyroid nodule was classified into group A and B according to the largest diameter (1 mm {<=} group A < 3 mm and 3 mm {<=} group B < 5 mm). The adequacy and accuracy of US-FNA in two groups were compared using the histopathological results as a reference standard. Of the 227 thyroid nodules in 201 patients, the inadequacy of US-FNA in group A and B was 24.3% (18/74) and 13.1% (20/153), respectively, showing a statistically significant difference between the two groups (p = 0.0333, chi-square test). Eighty nodules were removed surgically in 72 patients, from which papillary thyroid carcinoma (n = 52), follicular thyroid carcinoma (n = 1), nodular hyperplasia (n = 26), and pseudonodule related to thyroiditis (n = 1) were confirmed. Based on the histopathological results of the 80 surgical nodules, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US-FNA in group A and B were 55.0% and 79.4%, 81.8% and 100%, 84.6% and 100%, 50% and 68.2%, and 64.5% and 85.7%, respectively. The adequacy and accuracy of US-FNA for solid thyroid nodules, {>=} 3 mm in the largest diameter, were higher than those of US-FNA for very small nodules, < 3 mm in the largest diameter

  7. Comparision of Incidental Reflection From Containerized Maintenance/Housekeeping Solutions and One Inch of Water

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Bryan Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); MacQuigg, Michael Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wysong, Andrew Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-15

    This document addresses the incidental reflector reactivity worth of containerized maintenance/housekeeping fluids for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze containerized maintenance/housekeeping fluids which will be analyzed as water that may be present under normal conditions of an operation. The reactivity worth is compared to the reactivity worth due to I-inch of close-fitting 4n water reflection and I-inch of close-fitting radial water reflection. Both have been used to bound incidental reflection by 2-liter bottles in criticality safety evaluations. The conclusion is that, when the maintenance/housekeeping fluids are containerized the reactivity increase from a configuration which is bounding of normal conditions (up to eight bottles modeled with 2-liters of solution at varying diameter) is bound by I-inch of close fitting 4n water relection.

  8. Classification of grape berries according to diameter and total soluble solids to study the effect of light and temperature on methoxypyrazine, glutathione, and hydroxycinnamate evolution during ripening of Sauvignon blanc (Vitis vinifera L.).

    Science.gov (United States)

    Suklje, Katja; Lisjak, Klemen; Česnik, Helena Baša; Janeš, Lucija; Du Toit, Wessel; Coetzee, Zelmari; Vanzo, Andreja; Deloire, Alain

    2012-09-19

    Grape berries were classified according to diameter and total soluble solids (TSS) to study the effect of light and temperature on methoxypyrazines (MPs), glutathione (GSH), and hydroxycinnamates (HCAs) during the ripening of Sauvignon blanc. The light exposure of the fruiting zone was modified within leaf and lateral removal at the phenological stage berry of peppercorn size and no removal (control). In comparison to the control, the concentration of 3-isobutyl-2-methoxypyrazine (IBMP) was below the limit of detection in leaf removal 2 weeks before harvest. Leaf removal had no significant influence on GSH and HCAs in the grape juice at harvest. Berry diameter significantly influenced the concentration of IBMP in the grape juice and did not influence the concentration of GSH and HCAs. At harvest, the concentrations of IBMP in grape juices of similar TSS in the control were 12.6 and 5.2 ng/L in 15.5 and 13.5 mm berry diameter classes, respectively. Furthermore, the study showed that berries of the same diameter were not at the same physiological ripening level (not the same TSS).

  9. Test report on experimental stress analysis of a 24 inch diameter tee (ORNL T-13)

    International Nuclear Information System (INIS)

    Henley, D.R.

    1975-03-01

    The experimental stress analysis and low cycle fatigue test of one 24 in. x 24 in. x 10 in. schedule 160 carbon steel, ANSI B16.9 tee performed by Combustion Engineering, Inc. are described. The tee was instrumented with 230 rectangular strain gage rosettes. Elastic data was obtained for 12 loading conditions consisting of internal pressure and orthogonal pure moments and orthogonal direct forces applied individually to the free branch and run ends of the tee. One of the run ends of the tee was ''built in'' throughout the test. All loads were applied through pipe extensions welded to the tee. The tee was tested to failure in a low cycle pressure fatigue test with a cyclic internal pressure between 100 psi and 7000 psi. A through-the-wall fatigue crack occurred at 15,084 cycles. Significant test results are summarized and compared with design values tabulated in the ASME Boiler and Pressure Vessel Code, Section III, 1971. (U.S.)

  10. Am/Cm TTR testing - 3/8-inch glass beads evaluation in CIM5

    International Nuclear Information System (INIS)

    Witt, D. C.

    2000-01-01

    To facilitate the procurement and handling of the glass former for Am/Cm vitrification in the F-Canyon MPPF, 1/4 inch and 3/8 inch diameter glass beads were purchased from Corning for evaluation in the 5 inch Cylindrical Induction Melter (CIM5). Prior to evaluating the beads in the CIM5, tests were conducted in the Drain Tube Test Stand (DTTS) with 1/4 inch beads, 3/8 inch beads, and a 50/50 mixture to identify any process concerns. Results of the DTTS tests are summarized in Attachment 1. A somewhat larger volume expansion was experienced in all three DTTS runs as compared to a standard run using cullet. Further testing of the use of glass beads in the CIM5 was requested by the Design Authority as Task 1.02 of Technical Task Request 99-MNSS/SE-006. Since the Technical Task Plan was not yet approved, the completion of this task was conducted under an authorization request approved by the SRTC Laboratory Director, S. Wood. This request is included as Attachment 2

  11. Computational fluid dynamics analysis of space shuttle main propulsion feed line 17-inch disconnect valves

    Science.gov (United States)

    Kandula, Max; Pearce, Daniel

    1989-01-01

    A steady incompressible three-dimensional (3-D) viscous flow analysis was conducted for the Space Shuttle Main Propulsion External Tank (ET)/Orbiter (ORB) propellant feed line quick separable 17-inch disconnect flapper valves for liquid oxygen (LO2) and liquid hydrogen (LH2). The main objectives of the analysis were to predict and correlate the hydrodynamic stability of the flappers and pressure drop with available water test data. Computational Fluid Dynamics (CFD) computer codes were procured at no cost from the public domain, and were modified and extended to carry out the disconnect flow analysis. The grid generator codes SVTGD3D and INGRID were obtained. NASA Ames Research Center supplied the flow solution code INS3D, and the color graphics code PLOT3D. A driver routine was developed to automate the grid generation process. Components such as pipes, elbows, and flappers can be generated with simple commands, and flapper angles can be varied easily. The flow solver INS3D code was modified to treat interior flappers, and other interfacing routines were developed, which include a turbulence model, a force/moment routine, a time-step routine, and initial and boundary conditions. In particular, an under-relaxation scheme was implemented to enhance the solution stability. Major physical assumptions and simplifications made in the analysis include the neglect of linkages, slightly reduced flapper diameter, and smooth solid surfaces. A grid size of 54 x 21 x 25 was employed for both the LO2 and LH2 units. Mixing length theory applied to turbulent shear flow in pipes formed the basis for the simple turbulence model. Results of the analysis are presented for LO2 and LH2 disconnects.

  12. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  13. The Six-Inch Lunar Atlas A Pocket Field Guide

    CERN Document Server

    Spain, Don

    2009-01-01

    The Six-Inch Lunar Atlas has been designed specifically for use in the field by lunar observers so it’s perfect for fitting into an observer’s pocket! The author’s own lunar photographs were taken with a 6-inch (150mm) telescope and CCD camera, and closely match the visual appearance of the Moon when viewed through 3-inch to 8-inch telescopes. Each picture is shown oriented "as the Moon really is" when viewed from the northern hemisphere, and is supplemented by exquisite computer sketches that list the main features. Two separate computer sketches are provided to go with each photograph, one oriented to appear as seen through an SCT telescope (e.g. the Meade and Celestron ranges), the other oriented for Newtonian and refracting telescopes. Observers using the various types telescopes will find it extremely helpful to identify lunar features as the human brain is very poor at making "mirror-image" visual translations.

  14. Aerosol Research Branch (ARB) 48 inch Lidar Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARB_48_IN_LIDAR data set contains data collected from a 48-inch lidar system located at NASA Langley Research Center. Each granule consists of one year of data....

  15. 16 CFR 500.19 - Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI...

    Science.gov (United States)

    2010-01-01

    .../pound quantities and inch/pound quantities to SI metric quantities. 500.19 Section 500.19 Commercial... LABELING ACT § 500.19 Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI metric quantities. (a) For calculating the conversion of SI metric quantities to inch/pound...

  16. Development of 52 inches last stage blade for steam turbines

    International Nuclear Information System (INIS)

    Suzuki, Atsuhide; Hisa, Shoichi; Nagao, Shinichiro; Ogata, Hisao

    1986-01-01

    The last stage blades of steam turbines are the important component controlling the power output and performance of plants. In order to realize a unit of large capacity and high efficiency, the proper exhaust area and the last stage blades having good performance are indispensable. Toshiba Corp. has completed the development of the 52 inch last stage blades for 1500 and 1800 rpm steam turbines. The 52 inch last stage blades are the longest in the world, which have the annular exhaust area nearly 1.5 times as much as that of 41 inch blades used for 1100 MW, 1500 rpm turbines in nuclear power stations. By adopting these 52 inch blades, the large capacity nuclear power plants up to 1800 MW can be economically constructed, the rate of heat consumption of 1350 MW plants is improved by 3 ∼ 4 % as compared with 41 inch blades, and in the plants up to 1100 MW, LP turbines can be reduced from three sets to two. The features of 52 inch blades, the flow pattern and blade form design, the structural strength analysis and the erosion withstanding property, and the verification by the rotation test of the actual blades, the performance test using a test turbine, the vibration analysis of the actually loaded blades and the analysis of wet steam behavior are reported. (Kako, I.)

  17. Refurbishment and modification of existing protective shipping packages (for 30-inch UF{sub 6} cylinders) per USDOT specification No. USA-DOT-21PF-1A

    Energy Technology Data Exchange (ETDEWEB)

    Housholder, W.R. [Nuclear Containers, Incorporated, Elizabethton, TN (United States)

    1991-12-31

    This paper addresses the refurbishment procedures for existing shipping containers for 30-inch diameter UF{sub 6} cylinders in accordance with DOT Specification 21PF-1 and the criteria used to determine rejection when such packages are unsuitable for refurbishment.

  18. A PROTOTYPE FOUR INCH SHORT HYDRIDE (FISH) BED AS A REPLACEMENT TRITIUM STORAGE BED

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.; Estochen, E.; Shanahan, K.; Heung, L.

    2011-02-23

    The Savannah River Site (SRS) tritium facilities have used 1st generation (Gen1) metal hydride storage bed assemblies with process vessels (PVs) fabricated from 3 inch nominal pipe size (NPS) pipe to hold up to 12.6 kg of LaNi{sub 4.25}Al{sub 0.75} metal hydride for tritium gas absorption, storage, and desorption for over 15 years. The 2nd generation (Gen2) of the bed design used the same NPS for the PV, but the added internal components produced a bed nominally 1.2 m long, and presented a significant challenge for heater cartridge replacement in a footprint limited glove-box. A prototype 3rd generation (Gen3) metal hydride storage bed has been designed and fabricated as a replacement candidate for the Gen2 storage bed. The prototype Gen3 bed uses a PV pipe diameter of 4 inch NPS so the bed length can be reduced below 0.7 m to facilitate heater cartridge replacement. For the Gen3 prototype bed, modeling results show increased absorption rates when using hydrides with lower absorption pressures. To improve absorption performance compared to the Gen2 beds, a LaNi{sub 4.15}Al{sub 0.85} material was procured and processed to obtain the desired pressure-composition-temperature (PCT) properties. Other bed design improvements are also presented.

  19. 76 FR 7815 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2011-02-11

    ... International Trade Administration Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure... certain large diameter carbon and alloy seamless standard, line, and pressure pipe (over 4\\1/2\\ inches... with sections 751(a)(3)(A) and 777(i)(1) of the Act. Dated: February 3, 2011. Christian Marsh, Deputy...

  20. 77 FR 59374 - Certain Small Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe (Under 41/2

    Science.gov (United States)

    2012-09-27

    ...] Certain Small Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe (Under 4\\1/2\\ Inches... administrative review of the antidumping order on certain small diameter carbon and alloy seamless standard, line...: September 20, 2012. Christian Marsh, Deputy Assistant Secretary for Antidumping and Countervailing Duty...

  1. Separation Efficiency of Nagar Parker China Clay Using Two Inch Hydrocyclone

    Directory of Open Access Journals (Sweden)

    Abdul Ghani Pathan

    2013-01-01

    Full Text Available Performance efficiency of two inch hydrocyclone has been investigated, using the Nagar Parker china clay. Raw china clay was initially washed with tap water and -75 ?m size fraction was separated through wet sieving. Washed china clay of -75 ?m was used as feed sample in hydrocyclone tests. Solids concentration in slurry was kept as 2.5%. 45 tests were conducted with different combinations of pressure, vortex finder and spigot. Three sizes of spigot viz. 3.2, 2.2 and 1.5mm and three sizes of vortex finder viz. 7.00, 5.5 and 3.00mm were used. Hydrocyclone rig was operated at five different pressures viz. 20, 30, 40, 50 and 60 psi in conjunction with various combinations of vortex finder and spigot. Laser light scattering technique was used for particle size analysis of O/F (Overflow and U/F (Underflow products. Separation efficiency of the hydrocyclone, for various combinations of Vortex Finder, Spigot and operating pressure, was determined for two size fractions, i.e. less than ten micron and less than twenty micron, present in O/F and U/F products. From the results it was concluded that the best separation efficiency of 2 inch hydrocyclone is achieved by using the vortex finder of 7.0mm size and spigot of 1.5mm size. It was also concluded that the separation efficiency of the hydrocyclone decreases by increasing the pressure.

  2. 78 FR 22843 - Small Diameter Graphite Electrodes From the People's Republic of China: Affirmative Preliminary...

    Science.gov (United States)

    2013-04-17

    ..., produced and/or exported by Sinosteel Jilin Carbon Co., Ltd. and Jilin Carbon Import & Export Company (collectively, ``Jilin Carbon''), with an actual or nominal diameter of 17 inches, and otherwise meeting the... memorandum from Christian Marsh, Deputy Assistant Secretary for Antidumping and Countervailing Duty...

  3. Production of medical radioisotopes in ORNL 86-Inch Cyclotron

    International Nuclear Information System (INIS)

    Skidmore, M.R.

    1975-01-01

    Procedures, targets, and costs are discussed for the production of iodine-123 at the ORNL 86-Inch Cyclotron. The cyclotron is a fixed frequency machine producing 22-MeV proton beams with currents of 3 mA. Flat plate targets are used in the bombardment of readily fabricated metals when highest production rates are necessary, while capsule targets are used when flat plate coatings are difficult or when high production rates are not required. Window targets with metal foils or powders, inorganic compounds, or isotopically enriched materials are also used. (PMA)

  4. Small diameter carbon nanopipettes

    Science.gov (United States)

    Singhal, Riju; Bhattacharyya, Sayan; Orynbayeva, Zulfiya; Vitol, Elina; Friedman, Gary; Gogotsi, Yury

    2010-01-01

    Nanoscale multifunctional carbon probes facilitate cellular studies due to their small size, which makes it possible to interrogate organelles within living cells in a minimally invasive fashion. However, connecting nanotubes to macroscopic devices and constructing an integrated system for the purpose of fluid and electrical signal transfer is challenging, as is often the case with nanoscale components. We describe a non-catalytic chemical vapor deposition based method for batch fabrication of integrated multifunctional carbon nanopipettes (CNPs) with tip diameters much smaller (10-30 nm) than previously reported (200 nm and above) and approaching those observed for multiwalled carbon nanotubes. This eliminates the need for complicated attachment/assembly of nanotubes into nanofluidic devices. Variable tip geometries and structures were obtained by controlled deposition of carbon inside and outside quartz pipettes. We have shown that the capillary length and gas flow rate have a marked effect on the carbon deposition. This gives us a flexible protocol, useful for growing carbon layers of different thicknesses at selective locations on a glass pipette to yield a large variety of cellular probes in bulk quantities. The CNPs possess an open channel for fluid transfer with the carbon deposited inside at 875 °C behaving like an amorphous semiconductor. Vacuum annealing of the CNP tips at temperatures up to 2000 °C yields graphitic carbon structures with an increase in conductivity of two orders of magnitude. Penetration of the integrated carbon nanoprobes into cells was shown to produce minimal Ca2+ signals, fast recovery of basal Ca2+ levels and no adverse activation of the cellular metabolism during interrogation times as long as 0.5-1 h.

  5. Optimizing Facility Configurations and Operating Conditions for Improved Performance in the NASA Ames 24 Inch Shock Tube

    Science.gov (United States)

    Bogdanoff, David W.; Cruden, Brett A.

    2016-01-01

    The Ames Electric Arc Shock Tube (EAST) is a shock tube wherein the driver gas can be heated by an electric arc discharge. The electrical energy is stored in a 1.2 MJ capacitor bank. Four inch and 24 inch diameter driven tubes are available. The facility is described and the need for testing in the 24 inch tube to better simulate low density NASA mission profiles is discussed. Three test entries, 53, 53B and 59, are discussed. Tests are done with air or Mars gas (95.7% CO2/2.7% N2/1.6% Ar) at pressures of 0.01 to 0.14 Torr. Velocities spanned 6.3-9.2 km/s, with a nominal center of 7 km/s. Many facility configurations are studied in an effort to improve data quality. Various driver and driven tube configurations and the use of a buffer section between the driver and the driven tube are studied. Diagnostics include test times, time histories of the shock light pulses and tilts of the shock wave off the plane normal to the tube axis. The report will detail the results of the various trials, give the best configuration/operating conditions found to date and provide recommendations for further improvements. Finally, diaphragm performance is discussed.

  6. The DIAMET campaign

    Science.gov (United States)

    Vaughan, G.

    2012-04-01

    DIAMET (DIAbatic influences on Mesoscale structures in ExTratropical storms) is a joint project between the UK academic community and the Met Office. Its focus is on understanding and predicting mesoscale structures in synoptic-scale storms, and in particular on the role of diabatic processes in generating and maintaining them. Such structures include fronts, rain bands, secondary cyclones, sting jets etc, and are important because much of the extreme weather we experience (e.g. strong winds, heavy rain) comes from such regions. The project conducted two field campaigns in the autumn of 2011, from September 14 - 30 and November 24 - December 14, based around the FAAM BAe146 aircraft with support from ground-based radar and radiosonde measurements. Detailed modelling, mainly using the Met Office Unified model, supported the planning and interpretation of these campaigns. This presentation will give a brief overview of the campaigns. Both in September and November-December the weather regime was westerly, with a strong jet stream directed across the Atlantic. Three IOPs were conducted in September, to observe a convective band ahead of an upper-level trough, waves on a long trailing cold front, and a warm conveyor belt associated with a secondary cyclone. In November-December six IOPs were conducted, to observe frontal passages and high winds. This period was notable for a number of very strong windstorms passing across the north of the UK, and gave us an opportunity to examine bent-back warm fronts in the southern quadrant of these storms where the strongest winds are found. The case studies fell into two basic patterns. In the majority of cases, dropsonde legs at high level were used to obtain a cross-section of winds and thermodynamic structure (e.g. across a front), followed by in situ legs at lower levels (generally where the temperature was between 0 and -10°) to examine microphysical processes, especially ice multiplication and the extent of supercooled water

  7. Numerical and experimental study of a solid pellet feed continuous Czochralski growth process for silicon single crystals

    Science.gov (United States)

    Anselmo, A.; Prasad, V.; Koziol, J.; Gupta, K. P.

    1993-07-01

    A polysilicon pellets (≅1 mm diameter) feed continuous Czochralski (CCZ) growth process for silicon single crystals is proposed and investigated. Experiments in an industrial puller (14-18 inch diameter crucible) successfully demonstrate the feasibility of this process. The advantages of the proposed scheme are: a steady state growth process, a low aspect ratio melt, uniformity of heat addition and a growth apparatus with single crucible and no baffle(s). The addition of dopant with the solid charge will allow a better control of oxygen concentration leading to crystals of uniform properties and better quality. This paper presents theoretical results on melting of fully and partially immersed silicon spheres and numerical solutions on temperature and flow fields in low aspect ration melts with and without the addition of solid pellets. The theoretical and experimental results obtained thus far show a great promise for the proposed scheme.

  8. Packing configuration performance for small stem diameters

    International Nuclear Information System (INIS)

    Aikin, J.A.; Spence, C.G.; Cumming, D.

    1997-01-01

    The extensive use of graphite packing and its excellent track record for large isolating valves in CANDU, Primary Heat Transfer (PHT) systems has resulted in an increased application of graphite packing on the conventional side. Many of these applications are in air operated valves (AOVs) where the packing sets are used on small stem diameters (<1 inch) with frequent short-cycling strokes (± 10% of full stroke). The direct application of the proven packing configurations for large isolated valves to control valve application has generated problems such as stiction, packing wear and, in isolated cases, stem stall. To address this issue, a test program was conducted at AECL, CRL by MED branch. The testing showed that by reconfiguring the packing sets and using PTFE wafers reductions in stem friction of 50% at ambient conditions, a 3 fold at hot conditions are achievable. The test program also demonstrated benefits gained in packing wear with different stem roughness finishes and the potential need to exercise small stems valves that see less than full stroke cycling. The paper describes the tests results and provides field support experience. (author)

  9. Remote target removal for the Oak Ridge 86-inch Cyclotron

    International Nuclear Information System (INIS)

    Walls, A.A.

    1982-01-01

    A remotely operated target remover has been plaed in operation at the 86-Inch Cyclotron located in Oak Ridge. The system provides for the remote removal of a target from inside the cyclotron, loading it into a cask, and the removal of the cask from the 1.5 m (5-ft) shielding walls. The remote system consists of multiple electrical and pneumatically operated equipment which is designed for controlled step-by-step operation, operated with an electrical control panel, and monitored by a television system. The target remover has reduced the radiation exposures to operating personnel at the facility and has increased the effective operating time. The system is fast, requires a minimum of skill to operate, and has demonstrated both reliability and durability

  10. Differences in mean fibre diameter and fibre diameter variance in ...

    African Journals Online (AJOL)

    sampled at five different body locations (Figure 1) at an age of 15 months. Samples were analysed by the Wool Testing. Bureaux, using an Optical Fibre Diameter Analyser which measured 4000 individual fibres in each sample. Apart from the mean, the variance of fibre diameter within samples was available. The statistical ...

  11. Wheel Diameter and Speedometer Reading

    Science.gov (United States)

    Murray, Clifton

    2010-01-01

    Most introductory physics students have seen vehicles with nonstandard wheel diameters; some may themselves drive "low-rider" cars or "big-wheel" pickup trucks. But how does changing wheel diameter affect speedometer readout for a given speed? Deriving the answer can be followed readily by students who have been introduced to rotation, and it…

  12. Nanocrystalline solids

    International Nuclear Information System (INIS)

    Gleiter, H.

    1991-01-01

    Nanocrystalline solids are polycrystals, the crystal size of which is a few (typically 1 to 10) nanometres so that 50% or more of the solid consists of incoherent interfaces between crystals of different orientations. Solids consisting primarily of internal interfaces represent a separate class of atomic structures because the atomic arrangement formed in the core of an interface is known to be an arrangement of minimum energy in the potential field of the two adjacent crystal lattices with different crystallographic orientations on either side of the boundary core. These boundary conditions result in atomic structures in the interfacial cores which cannot be formed elsewhere (e.g. in glasses or perfect crystals). Nanocrystalline solids are of interest for the following four reasons: (1) Nanocrystalline solids exhibit an atomic structure which differs from that of the two known solid states: the crystalline (with long-range order) and the glassy (with short-range order). (2) The properties of nanocrystalline solids differ (in some cases by several orders of magnitude) from those of glasses and/or crystals with the same chemical composition, which suggests that they may be utilized technologically in the future. (3) Nanocrystalline solids seem to permit the alloying of conventionally immiscible components. (4) If small (1 to 10 nm diameter) solid droplets with a glassy structure are consolidated (instead of small crystals), a new type of glass, called nanoglass, is obtained. Such glasses seem to differ structurally from conventional glasses. (orig.)

  13. Performance and Flowfield Measurements on a 10-inch Ducted Rotor VTOL UAV

    Science.gov (United States)

    Martin, Preston; Tung, Chee

    2004-01-01

    A ducted fan VTOL UAV with a 10-inch diameter rotor was tested in the US Army 7-by 10-Foot Wind Tunnel. The test conditions covered a range of angle of attack from 0 to 110 degrees to the freestream. The tunnel velocity was varied from 0 (simulating a hover condition) to 128 ft/sec in propeller mode. A six-component internal balance measured the aerodynamic loads for a range of model configurations. including the isolated rotor, the isolated duct, and the full configuration of the duct and rotor. For some conditions, hotwire velocity surveys were conducted along the inner and outer surface of the duct and across the downstream wake. In addition, fluorescent oil flow visualization allowed the flow separation patterns inside and outside of the duct to be mapped for a few test conditions. Two different duct shapes were tested to determine the performance effects of leading edge radius. For each duct, a range of rotor tip gap from 1%R to 4.5%R was tested to determine the performance penalty in hover and axial flight. Measured results are presented in terms of hover performance, hover performance in a crosswind, and high angle of attack performance in propeller mode. In each case, the effects of both tip gap and duct leading edge radius are illustrated using measurements. Some of the hover performance issues were also studied using a simple analytical method, and the results agreed with the measurements.

  14. Development of 8-inch Key Processes for Insulated-Gate Bipolar Transistor

    Directory of Open Access Journals (Sweden)

    Guoyou Liu

    2015-09-01

    Full Text Available Based on the construction of the 8-inch fabrication line, advanced process technology of 8-inch wafer, as well as the fourth-generation high-voltage double-diffused metal-oxide semiconductor (DMOS+ insulated-gate bipolar transistor (IGBT technology and the fifth-generation trench gate IGBT technology, have been developed, realizing a great-leap forward technological development for the manufacturing of high-voltage IGBT from 6-inch to 8-inch. The 1600 A/1.7 kV and 1500 A/3.3 kV IGBT modules have been successfully fabricated, qualified, and applied in rail transportation traction system.

  15. Diameter 2 properties and convexity

    Czech Academy of Sciences Publication Activity Database

    Abrahamsen, T. A.; Hájek, Petr Pavel; Nygaard, O.; Talponen, J.; Troyanski, S.

    2016-01-01

    Roč. 232, č. 3 (2016), s. 227-242 ISSN 0039-3223 R&D Projects: GA ČR GA16-07378S Institutional support: RVO:67985840 Keywords : diameter 2 property * midpoint locally uniformly rotund * Daugavet property Subject RIV: BA - General Mathematics Impact factor: 0.535, year: 2016 https://www.impan.pl/pl/wydawnictwa/czasopisma-i-serie-wydawnicze/studia- mathematica /all/232/3/91534/diameter-2-properties-and-convexity

  16. A small-diameter NMR logging tool for groundwater investigations

    Science.gov (United States)

    Walsh, David; Turner, Peter; Grunewald, Elliot; Zhang, Hong; Butler, James J.; Reboulet, Ed; Knobbe, Steve; Christy, Tom; Lane, John W.; Johnson, Carole D.; Munday, Tim; Fitzpatrick, Andrew

    2013-01-01

    A small-diameter nuclear magnetic resonance (NMR) logging tool has been developed and field tested at various sites in the United States and Australia. A novel design approach has produced relatively inexpensive, small-diameter probes that can be run in open or PVC-cased boreholes as small as 2 inches in diameter. The complete system, including surface electronics and various downhole probes, has been successfully tested in small-diameter monitoring wells in a range of hydrogeological settings. A variant of the probe that can be deployed by a direct-push machine has also been developed and tested in the field. The new NMR logging tool provides reliable, direct, and high-resolution information that is of importance for groundwater studies. Specifically, the technology provides direct measurement of total water content (total porosity in the saturated zone or moisture content in the unsaturated zone), and estimates of relative pore-size distribution (bound vs. mobile water content) and hydraulic conductivity. The NMR measurements show good agreement with ancillary data from lithologic logs, geophysical logs, and hydrogeologic measurements, and provide valuable information for groundwater investigations.

  17. Lowell Observatory's 24-inch Clark Refractor: Its History and Renovation

    Science.gov (United States)

    Schindler, Kevin; Nye, Ralph; Rosenthal, Peter

    2016-01-01

    In 1895, Percival Lowell hired eminent telescope maker Alvan G. Clark to build a 24-inch refractor. Lowell intended the telescope intitally for observing Mars in support of his controversial theories about life on that planet. Clark finished the telescope within a year and at a cost of $20,000. Lowell and his staff of assistants and astronomers began observing through it on July 23, 1896, setting off a long and productive career for the telescope.While Lowell's Mars studies dominated early work with the Clark, V.M. Slipher by the 1910s was using it to observe planetary rotations and atmospheric compositions. He soon revolutionized spectroscopic studies, gathering excruciatingly long spectra - some in excess of 40 hours - of the so-called white nebula and determining startling radial velocities, evidence of an expanding universe. In the 1960s, scientists and artists teamed up on the Clark and created detailed lunar maps in support of the Apollo program.In recent decades, the Clark has played a central role in the education programs at Lowell, with general public audiences, students, and private groups all taking advantage of this unique resource.With this nearly 120 years of contant use, the Clark had been wearing down in recent years. The telescope was becoming more difficult to move, old electrical wiring in the dome was a fire hazard, and many of the telescope's parts needed to be repaired or replaced.In 2013, Lowell Observatory began a fundraising campaign, collecting $291,000 to cover the cost of dome and telescope renovation. Workers removed the entire telescope mount and tube assembly from the dome, examining every part from tube sections to individuals screws. They also stabilized the dome, adding a water vapor barrier and new outer wall while reinforcing the upper dome. The project lasted from January, 2014 through August, 2015. The facility reopened for daytime tours in September, 2015 and evening viewing the following month.

  18. Experimental Investigation of Project Orion Crew Exploration Vehicle Aeroheating: LaRC 20-Inch Mach 6 Air Tunnel Test 6931

    Science.gov (United States)

    Hollis, Brian R.

    2009-01-01

    An investigation of the aeroheating environment of the Project Orion Crew Entry Vehicle has been performed in the Langley Research Center 20-Inch Mach 6 Air Tunnel. Data were measured on a approx.3.5% scale model (0.1778-m/7-inch diameter) of the vehicle using coaxial thermocouples at free stream Reynolds numbers of 2.0 10(exp 6)/ft to 7.30 10(exp 6)/ft and computational predictions were generated for all test conditions. The primary goals of this test were to obtain convective heating data for use in assessing the accuracy of the computational technique and to validate test methodology and heating data from a test of the same wind tunnel model in the Arnold Engineering Development Center Tunnel 9. Secondary goals were to determine the extent of transitional/turbulent data which could be produced on a CEV model in this facility, either with or without boundary-layer trips, and to demonstrate continuous pitch-sweep operation in this tunnel for heat transfer testing.

  19. Diameters of classes of smooth functions

    Science.gov (United States)

    Kudryavtsev, S. N.

    1995-08-01

    We describe the weak asymptotic behaviour of diameters of n-th order of the unit ball of W_p^l H^\\omega (I^d) in L_q(I^d), where I=(0,1), in dependence on n. Namely we consider the Kolmogorov diameter, the Gel'fand diameter, the linear diameter, the Aleksandrov diameter and the entropy diameter.

  20. 16 CFR 460.20 - R-value per inch claims.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false R-value per inch claims. 460.20 Section 460.20 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES LABELING AND ADVERTISING OF HOME INSULATION § 460.20 R-value per inch claims. In labels, fact sheets, ads, or other promotional...

  1. Torque expression of 0.018 and 0.022 inch conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond(R) Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch.

  2. Comparison of silicon strip tracker module size using large sensors from 6 inch wafers

    CERN Multimedia

    Honma, Alan

    1999-01-01

    Two large silicon strip sensor made from 6 inch wafers are placed next to each other to simulate the size of a CMS outer silicon tracker module. On the left is a prototype 2 sensor CMS inner endcap silicon tracker module made from 4 inch wafers.

  3. Two inch large area patterning on a vertical light-emitting diode by nano-imprinting technology

    International Nuclear Information System (INIS)

    Byeon, Kyeong-Jae; Hong, Eun-Ju; Park, Hyoungwon; Yoon, Kyung-Min; Lee, Heon; Song, Hyun Don; Lee, Jin Wook; Kim, Sun-Kyung; Cho, Hyun Kyong; Kwon, Ho Ki

    2010-01-01

    A vertical light-emitting diode (LED) with a chip size of 500 × 500 µm 2 was fabricated by the laser lift-off (LLO) process of an InGaN-based blue LED wafer. After the LLO process, photonic crystal patterns by UV nano-imprint lithography were formed on the n-GaN top layer of the vertical LED over the entire area with a diameter of 2 inches. As the result of n-GaN patterning, light output power of the vertical LED with photonic crystals was increased by up to 44% compared to that of the vertical LED without a photonic crystal at a driving current of 1000 mA

  4. Effect of logging wounds on diameter growth of sawlog-size Appalachian hardwood crop trees

    Science.gov (United States)

    Neil I. Lamson; H. Clay Smith; H. Clay Smith

    1988-01-01

    In previously thinned, even-aged Appalachian hardwood stands, 5-year diameter growth of 102 wounded and 102 unwounded codominant crop trees were compared. A wounded crop tre was defined as one with at least one exposed sapwood logging wound at least 100 inch2 in size. An unwounded crop tree of the same species and size was selected near each of the 102 wounded trees....

  5. Application of Derrick Corporation's stack sizer technology for slimes reduction in 6 inch clean coal hydrocyclone circuits

    Energy Technology Data Exchange (ETDEWEB)

    Brodzik, P.

    2009-04-15

    The article discusses the successful introduction of Derrick Corporation's Stack Sizer technology for removing minus 200 mesh slimes from 6-inch coal hydrocyclone underflow prior to froth flotation or dewatering by screen bowl centrifuges. In 2006, the James River Coal Company selected the Stack Sizer fitted with Derrick 150 micron and 100 micron urethane screen panels for removal of the minus 100 mesh high ash clay fraction from the clean coal spiral product circuits. After this application proved successful, Derrick Corporation introduced new 75 micron urethane screen panels for use on the Stack Sizer. Evaluation of feed slurry to flotation cells and screen bowl centrifuges showed significant amounts of minus 75 micron that could potentially be removed by efficient screening technology. Removal of the minus 75 micron fraction was sought to reduce ash and moisture content of the final clean coal product. Full-scale lab tests confirmed that the Stack Sizer fitted with Derrick 75 micron urethane screen panels consistently reduced the minus 75 micron percentage in coal slurry from 6-inch clean coal hydrocyclone underflow that is approximately 15 to 20% solid by-weight and 30 to 60% minus 75 micron to a clean coal fraction that is approximately 13 to 16% minus 75 micron. As a result total ash is reduced from approximately 36 to 38% in the hydrocyclone underflow to 14 to 16% in the oversize product fraction form the Stack Sizers. 1 fig., 2 tabs., 5 photos.

  6. Determination of the Tapping Part Diameter of the Thread Mill

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2015-01-01

    Full Text Available Currently, there is a tendency to increase the proportion of thread milling operations, among other ways of tapping, which is associated with increasing number of CNC machines, flexibility and versatility of the process.Developments presently existing in the RF and used in the thread mills deal, mainly, with the thread milling cutter designs, to process internal and external thread with straight flutes made from high-speed steel.The paper presents a technique to calculate and select the initial design parameters, i.e. the external diameter of the tapping part of thread milling cutter, which is chosen as a basic computational design. The analysis of directories of tool companies containing foreign de-signs of solid thread end-milling cutters has shown that most of them rep-resent the thread cutter designs made of solid carbide. There are solid and interlocking side milling cutters, which use a tapping part both as a single-disk and as a multi-disk one; chip flutes are made to be both as direct and as screw; solid designs of cutters are made from carbide with a diameter of up to 20 ... 25 mm; thread cutters can be left- and right-hand cutting; Designs of the combined thread mills are proposed; internal channels are used for coolant supply.It is shown that the purpose of the external diameter of the tapping part of the thread mill should take into account the effect of the thread mill diameter on the milling process performance, precision of thread profile received, taper thread, tool strength, and the volume of flutes.The analysis has shown that when choosing the external diameter of the thread mill it worth taking its maximum diameter to improve the char-acteristics of the process under the restrictions imposed on the accuracy of the formed thread.

  7. MT. BIGELOW 61-INCH IMAGES OF 9P/TEMPEL 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains 6 images of 9P/Tempel 1 obtained on five nights in 1994 using a visual CCD mounted on the 61-inch Kuiper telescope of the Mt. Bigelow...

  8. Corrosion and deposit determination in large diameter pipes by radiography

    International Nuclear Information System (INIS)

    Harara, W.

    2006-08-01

    Two steel reference pipes with outer diameters of 8 and 12 inches were machined to make artificial defects on each of them, such as inside and outside steps of different wall thicknesses, inside and outside flat bottomed holes (FBH) of different diameters and depths on steps, flat area (FA), and ground patch (GP). The artificial defect were made to simulate natural corrosion attack as regular corrosion and pitting. The two reference pipes were tested according to tangential radiography technique and double wall single image technique. Tangential radiography technique had been applied using Co-60 radio-isotope to determine the steps thicknesses, the FBH, the remaining wall thickness under the FA, the remaining wall thickness above the GP, and the minimum detectable thickness of the artificial cement deposit on the two reference pipes, with and without insulation. Double wall single image technique had also been applied on the two reference pipes with and without insulation using Ir-192 radio-isotope to measure the flat bottomed holes depths, GP depth, and FA depth by density measurement. The measurement results obtained from the radiographs confirm that, tangential radiography technique can be applied to detect and evaluate the inside and outside regular corrosion attack in the large diameter pipes. It can also be applied to detect and evaluate the outside FBH with depth equal or greater than 10%. Inside 10% FBH and inside 20% FBH can not be detected if their diameters are not larger than certain value related to diameter and wall thickness of the pipe under test. Increasing the film density up to 5 outside the pipe did not provide any detection improvement of 10% and 20% inside FBH. Tangential radiography technique can also be applied to detect and measure the deposit inside the pipes. Double wall technique can be applied as an alternative method of the tangential radiography technique to detect and to evaluate the shallow and small diameter, 10% and 20% inside FBH

  9. Risk assessment of K Basin twelve-inch and four-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-06-23

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rate which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. Five four-inch drain valves are located in the north and south loadout pits (NLOP and SLOP), the weasel pit, the technical viewing pit, and the discharge chute pit. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations indicate that only the valve's bonnet and stem are exposed above the basin concrete floor for the twelve-inch drain valve and that much less of the valve's bonnet and stem are exposed above the basin concrete floor for the five four-inch drain valves. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this analysis are to: (1) evaluate the likelihood of damaging the three twelve-inch drain valves located along the north wall of the main basin and the five four-inch drain valves located in the pits from a seismic initiating event, and (2) determine the likelihood of exceeding a specific consequence (initial leak rate) from a damaged valve. The analysis process is a risk-based uncertainty analysis where each variable is modeled using available information and engineering judgement. The uncertainty associated with each variable is represented by a probability distribution (probability density function). Uncertainty exists because of the inherent

  10. Development of gamma spectroscopy employing NaI(Tl) detector 3 inch x 3 inch and readout electronic of flash-ADC/FPGA-based technology

    Energy Technology Data Exchange (ETDEWEB)

    Hai, Vo Hong [HCMC-National Univ., Hochiminh City (Viet Nam). Inst. of Nuclear Physics; Ton Duc Thang Univ., Ho Chi Minh City (Viet Nam). Div. of Nuclear Physics; Hung, Nguyen Quoc [HCMC-National Univ., Hochiminh City (Viet Nam). Inst. of Nuclear Physics; Khai, Bui Tuan [Osaka Univ. (Japan). Dept. of Physics

    2015-05-15

    n this article the development of a gamma spectroscopy system is described using a scintillation detector NaI(Tl) of 3 inch x 3 inch. The readout electronic for the spectroscopy is built from the fast analog-digital conversion of Flash Analog-Digital Converter (Flash-ADC) 250 MHz - 8 bits resolution, and the embedded Field-Programmable Gate Array (FPGA) technology. The embedded VHSIC Hardware Description Language (VHDL) code for FPGA is built in such a way that it works as a multi channel analyser (MCA) with 4096 Digital Charge Integration (DCI) channels. A pulse generator with frequency varying from Hz up to 12 kHz is used to evaluate the time response of the system. Two standard radioisotope sources of {sup 133}Ba and {sup 152}Eu with multi gamma energies ranging from several tens keV to MeV are used to evaluate the linearity and energy resolution of the system.

  11. Blow-Out Velocities of Solutions of Hydrocarbons and Boron Hydride - Hydrocarbon Reaction Products in a 1 7/8-Inch-Diameter Combustor

    Science.gov (United States)

    Morris, James F.; Lord, Albert M.

    1957-01-01

    Blow-out velocities were determined for JP-4 solutions containing: (1) 10 % ethylene - decaborane reaction product, (2) 10% and 20% acetylene - diborane reaction product, and (3) 5.5%, 15.7%, and 30.7% methylacetylene - diborane reaction product. These were compared with blow-out velocities for JP-4, propylene oxide, and neohexane and previously reported data for JP-4 solutions of pentaborane. For those reaction products investigated, the blow-out velocities at a fixed equivalence ratio were higher for those materials containing higher boron concentrations; that is, blow-out velocity increased in the following order: (1) methylacetylene - diborane, (2) acetylene - diborane, and (3) ethylene - decaborane reaction products.

  12. SEX DETERMINATION FROM FEMORAL HEAD DIAMETERS IN ...

    African Journals Online (AJOL)

    hi-tech

    2000-03-01

    Mar 1, 2000 ... Request for reprints to: Dr. P S Igbigbi, Department of Anatomy, College of Medicine, Private Bag 360 Chichiri, Blantyre 3 Malawi. SEX DETERMINATION .... Figure 2. Bar chart showing the ranges of head diameters of male and female femurs. (RVD-Right vertical diameter; LVD-Left vertical diameter; RTD -.

  13. 7 CFR 51.2850 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Diameter. 51.2850 Section 51.2850 Agriculture... Diameter. Diameter means the greatest dimension measured at right angles to a straight line running from the stem to the root. ...

  14. 7 CFR 51.3211 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Diameter. 51.3211 Section 51.3211 Agriculture... Standards for Grades of Bermuda-Granex-Grano Type Onions Definitions § 51.3211 Diameter. Diameter means the greatest dimension of the onion at right angles to a line running from the stem to the root. Metric...

  15. On the performance of small diameter gas cyclones

    International Nuclear Information System (INIS)

    Halasz, Marcos Roberto Teixeira

    2002-02-01

    Small diameter cyclones represent a potential alternative for the removal of small diameter particles from gaseous mixtures as well as the environmental control of their emission. In order to establish feasible configurations of a small diameter cyclone applied in the separation of solid particles dispersed in a gas and considering a large quantify of experimental data in literature, neural networks were used to estimate the equipment grade efficiency and pressure drop. In order to evaluate a performance of many small diameters configurations and analysis was carried of parametrical sensibility which determines the most important variables on separation efficiency determination. A set of experimental runs was carried out in a lab-scale mini-cyclone in order to obtain the separation efficiency and pressure drop for different configurations, and evaluate the feasibility of coupling a post-cyclone device to improve the equipment overall performance. The cyclones used presented diameters of 0.03 and 0.05 m and the remaining dimensions varied proportionally about those found in Stairmand high-efficiency cyclones. Experimental separation efficiencies up to 99% were obtained in this work. These results confirm the feasibility of the experimental set-up configuration proposed. (author)

  16. Evaluation of 3 Inch SN-219 Failure and S and SX Tank Farm Saltwell Piping

    International Nuclear Information System (INIS)

    ELSEN, J.J.

    2000-01-01

    Evaluation of direct buried piping currently in use or designated for future Saltwell pumping in S and SX Farms. Documented evaluation of failed S-103 saltwell pumping transfer line 3 inch SN-219. This evaluation is intended to reflect current status of Saltwell piping, when taken in context with referenced documents

  17. Full scale ambient water flow tests of a 10-inch emergency release coupling for LNG transfer

    NARCIS (Netherlands)

    Putte, L.J. van der; Webber, T.; Bokhorst, E. van; Revell, C.

    2016-01-01

    For LNG transfer in ship-to-ship and ship-to-shore configurations emergency release couplings (F.RC) in combination with loading arms and multi-composite hoses are applied In view of a demand for increasing transfer flow rates in offshore LNG applications a 10-inch ERC has been developed intended

  18. Characterization and Detailed Analysis of Regression Behavior for HTPB Solid Fuels Containing High Aluminum Loadings

    Science.gov (United States)

    Kibbey, Timothy P.; Cortopassi, Andrew C.; Boyer, Eric C.

    2017-01-01

    NASA Marshall Space Flight Center's Materials and Processes Department, with support from the Propulsion Systems Department, has renewed the development and maintenance of a hybrid test bed for exposing ablative thermal protection materials to an environment similar to that seen in solid rocket motors (SRM). The Solid Fuel Torch (SFT), operated during the Space Shuttle program, utilized gaseous oxygen for oxidizer and an aluminized hydroxyl-terminated polybutadiene (HTPB) fuel grain to expose a converging section of phenolic material to a 400 psi, 2-phase flow combustion environment. The configuration allows for up to a 2 foot long, 5 inch diameter fuel grain cartridge. Wanting to now test rubber insulation materials with a turn-back feature to mimic the geometry of an aft dome being impinged by alumina particles, the throat area has now been increased by several times to afford flow similarity. Combined with the desire to maintain a higher operating pressure, the oxidizer flow rate is being increased by a factor of 10. Out of these changes has arisen the need to characterize the fuel/oxidizer combination in a higher mass flux condition than has been previously tested at MSFC, and at which the literature has little to no reporting as well. For (especially) metalized fuels, hybrid references have pointed out possible dependence of fuel regression rate on a number of variables: mass flux, G - oxidizer only (G0), or - total mass flux (Gtot), Length, L, Pressure, P, and Diameter, D.

  19. Performance of large diameter polyvinyl chloride (PVC) pipes in water applications

    Science.gov (United States)

    Deshmukh, Pradip P.

    Polyvinyl chloride (PVC) pipes are used in water management utilities to manage safe and efficient water transport. The material's advantages includes strength, flexibility, anti-corrosive properties and easy installation methods. The disadvantages include joint failure, pipe fractures, material contamination and oxidative degradation. This thesis evaluates the use of 24 inch and larger diameter PVC pipes in water management utilities. Center of Undergraduate Infrastructure and Research Education (CUIRE) conducted surveys consisting of questions pertaining to PVC pipe material and installation practices to different water management utilities. While PVC material is most commonly used in pipelines less than 24", the CUIRE responses show that PVC pipes are not the most common type of pipe material in 24" and larger diameters installed in the facilities for various reasons. These reasons are discussed and evaluated in hopes of understanding the material's fallbacks in the piping industry. Finally, future research recommendations are constructed for researchers in the PVC piping industry.

  20. Numerical Investigation of Liquid Carryover in T-Junction with Different Diameter Ratios

    Science.gov (United States)

    Pao, William; Sam, Ban; Saieed, Ahmed; Tran, Cong Minh

    2018-03-01

    In offshore Malaysia, T-junction is installed at the production header as a compact separator to tap produced gas from reservoir as fuel gas for power generation. However, excessive liquid carryover in T-junction presents a serious operational issue because it trips the whole production platform. The primary objective of present study is to numerically investigate the liquid carryover due to formation of slug, subsequently its liquid carryover at different diameter ratio. The analyses were carried out on a model with 0.0254 m (1 inch) diameter horizontal main arm and a vertically upward side arm using Volume of Fluid Method. Three different sides to main arm diameter ratio of 1.0, 0.5 and 0.3 were investigated with different gas and liquid superficial velocities. The results showed that, while the general trend is true that smaller diameter ratio T-junction has lesser liquid take off capacity, it has a very high frequency of low liquid carryover threshold. In other words, under slug flow, smaller diameter ratio T-junction is constantly transporting liquid even though at a lesser volume in comparison to regular T-junction.

  1. Shock shapes on blunt bodies in hypersonic-hypervelocity helium, air, and CO2 flows, and calibration results in Langley 6-inch expansion tube

    Science.gov (United States)

    Miller, C. G., III

    1975-01-01

    Shock shape results for flat-faced cylinders, spheres, and spherically blunted cones in various test gases, along with preliminary results from a calibration study performed in the Langley 6-inch expansion tube are presented. Free-stream velocities from 5 to 7 km/sec are generated at hypersonic conditions with helium, air, and CO2, resulting in normal shock density ratios from 4 to 19. Ideal-gas shock shape predictions, in which an effective ratio of specific heats is used as input, are compared with the measured results. The effect of model diameter is examined to provide insight to the thermochemical state of the flow in the shock layer. The regime for which equilibrium exists in the shock layer for the present air and CO2 test conditions is defined. Test core flow quality, test repeatability, and comparison of measured and predicted expansion-tube flow quantities are discussed.

  2. Health physics challenges involved with opening a "seventeen-inch" concrete waste vault.

    Science.gov (United States)

    Sullivan, Patrick T; Pizzulli, Michelle

    2005-05-01

    This paper describes the various activities involved with opening a sealed legacy "Seventeen-inch" concrete vault and the health physics challenges and solutions employed. As part of a legacy waste stream that was removed from the former Hazardous Waste Management Facility at Brookhaven National Laboratory, the "Seventeen-inch" concrete vault labeled 1-95 was moved to the new Waste Management Facility for ultimate disposal. Because the vault contained 239Pu foils with a total activity in excess of the transuranic waste limits, the foils needed to be removed and repackaged for disposal. Conventional diamond wire saws could not be used because of facility constraints, so this project relied mainly on manual techniques. The planning and engineering controls put in place enabled personnel to open the vault and remove the waste while keeping dose as low as reasonably achievable.

  3. Schlesinger's Telescope: A Brief History of the Yale 26-inch Refractor

    Science.gov (United States)

    van Altena, W. F.; Hoffleit, E. D.

    2003-08-01

    Frank Schlesinger began planning for the establishment of a southern observatory when he arrived at Yale in 1920. After discussing the possibility of a location in Auckland, New Zealand and gathering site survey observations for a four-month period, he decided to select a site in Johannesburg, South Africa. A large photographically corrected 26-inch objective was ground, polished and completed by James McDowell in 1923, while the telescope was built largely in the Yale shops in New Haven. Schlesinger left New Haven in 1924 with the lens, and the telescope followed shortly thereafter. Installation of the 26-inch refractor was completed in early June and dedicated by the Prince of Wales on June 22, 1924. The principal observational program for the 26-inch refractor was the determination of parallaxes of the bright stars and it was continued until 1952, when the telescope was moved to Mt. Stromlo due to the deteriorating sky conditions in Johannesburg. The parallax program continued at Mt. Stromlo until 1963 when the telescope was donated to the Commonwealth Observatory and the Yale-Columbia project moved to Argentina, Columbia having joined with Yale in 1943. Approximately 70,000 plates were taken with the refractor for the parallax programs and about 2,000 stellar parallaxes determined. The Schlesinger 26-inch refractor was destroyed by a firestorm on January 18, 2003, along with the other telescopes on Mount Stromlo, the workshop, library and many of the residences. This event was a sad ending to a telescope that played a major role in defining our knowledge of the distances, motions and masses of the brighter stars during the first half of the 20th century.

  4. Design of a 18F production system at ORNL 86-inch cyclotron

    International Nuclear Information System (INIS)

    Shaeffer, M.C.; Barreto, F.; Datesh, J.R.; Goldstein, B.R.

    1977-01-01

    A target system for the production of 18 F by proton bombardment of H 2 18 O was designed for the ORNL 86-inch cyclotron facility. The system consists of concentric titanium and aluminum cylinders. Oxygen-18-enriched H 2 O circulates through the inner titanium cylinder and through an external heat exchanger with cooling water flowing in the annulus. Yields of 5.0 curies are expected for a 250-μA proton beam current and 24-min irradiation time

  5. Aircraft Water-Based Solid Film Lubricants.

    Science.gov (United States)

    1983-06-10

    mately 1-1/2 inches in diameter. The underside of the screen shall be cautiously heated with a Bunsen burner in a manner which will not cause the flame ...to project through or above the screen. As soon as the compound begins to decompose or vilatilize, a second burner shall be used to ignite any vapors...evolved. The specimen will be considered nonflammable if the burning ceases as both burners are withdrawn from the screen. Heating shall be continued

  6. Digital image processing for diameter distribution evaluation of nuclear tracks

    International Nuclear Information System (INIS)

    Lira, J.; Camacho, S.; Balcazar-Garcia, M.; Peralta-Fabi, R.

    1984-01-01

    Fast reliable, and accurate evaluation of diameter distribution of nuclear tracks, etched on solid state nuclear detectors is necessary, to infer general information from the particular ions detected. To achieve this, it is primarily required to develop an on-line method, that is, a method fast enough so as the reading and information extraction processes became simultaneous. In order to accomplish this, adaptive matched filtering has been generalized to two dimensions; this lessens the noise content and the unwanted features present in the detector, and avoids distorting results significantly. (author)

  7. The George C. Marshall Space Flight Center's 14 X 14-Inch Trisonic Wind Tunnel: A Historical Perspective

    Science.gov (United States)

    Springer, A.

    1994-01-01

    A history of the National Aeronautics and Space Administration (NASA) George C. Marshall Space Flight Center's (MSFC) 14 x 14-Inch Trisonic Wind Tunnel is presented. Its early and continuing role in the United States space program is shown through highlights of the tunnel's history and the major programs tested in the tunnel over the past 40 years. The 14-Inch Tunnel has its beginning with the Army in the late 1950's under the Army Ballistic Missile Agency (ABMA). Such programs as the Redstone, Jupiter, Pershing, and early Saturn were tested in the 14-Inch Tunnel in the late 1950's. America's first launch vehicle, the Jupiter C, was designed and developed using the 14-Inch Wind Tunnel. Under NASA, the 14-Inch Wind Tunnel has made large contributions to the Saturn, Space Transportation System, and future launch vehicle programs such as Shuttle-C and the National Launch System. A technical description of the tunnel is presented for background information on the type and capabilities of the 14-Inch Wind Tunnel. The report concludes in stating: the 14-Inch Wind Tunnel as in speed of sound; transonic, at or near the speed of sound the past, will continue to play a large but unseen role in he development of America's space program.

  8. The effect of growth rate, diameter and impurity concentration on structure in Czochralski silicon crystal growth

    Science.gov (United States)

    Digges, T. G., Jr.; Shima, R.

    1980-01-01

    It is demonstrated that maximum growth rates of up to 80% of the theoretical limit can be attained in Czochralski-grown silicon crystals while maintaining single crystal structure. Attaining the other 20% increase is dependent on design changes in the grower, to reduce the temperature gradient in the liquid while increasing the gradient in the solid. The conclusions of Hopkins et al. (1977) on the effect of diameter on the breakdown of structure at fast growth rates are substantiated. Copper was utilized as the test impurity. At large diameters (greater than 7.5 cm), concentrations of greater than 1 ppm copper were attained in the solid (45,000 ppm in the liquid) without breakdown at maximum growth speeds. For smaller diameter crystals, the sensitivity of impurities is much more apparent. For solar cell applications, impurities will limit cell performance before they cause crystal breakdown for fast growth rates of large diameter crystals.

  9. Effective diameters and corresponding states of fluids

    Science.gov (United States)

    Del Río, Fernando

    Effective hard-sphere diameters of fluids with purely repulsive interactions are derived from a generalized corresponding-states principle of Leland, Rowlinson and coworkers. Various alternative definitions are discussed and related. Virial expansions of the effective diameters and their corresponding volumes are obtained and compared with results of perturbation theory. Applications are made to inverse-power potentials, the repulsive part of the Lennard-Jones potential and hard spherocylinders and dumbells.

  10. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  11. Bijective Diameters of Gene Tree Parsimony Costs.

    Science.gov (United States)

    Gorecki, Pawel; Eulenstein, Oliver

    2017-08-04

    Synthesizing median trees from a collection of gene trees under the biologically motivated gene tree parsimony (GTP) costs has provided credible species tree estimates. GTP costs are defined for each of the classic evolutionary processes. These costs count the minimum number of events necessary to reconcile the gene tree with the species tree where the leaf-genes are mapped to the leaf-species through a function called labeling. To better understand the synthesis of median trees under these costs there is an increased interest in analyzing their diameters. The diameters of a GTP cost between a gene tree and a species tree are the maximum values of this cost of one or both topologies of the trees involved. We are concerned about the diameters of the GTP costs under bijective labelings. While these diameters are linear time computable for the gene duplication and deep coalescence costs, this has been unknown for the classic gene duplication and loss, and for the loss cost. For the first time, we show how to compute these diameters and proof that this can be achieved in linear time, and thus, completing the computational time analysis for all of the bijective diameters under the GTP costs.

  12. A tape-controlled remote automatic diameter measurement machine

    International Nuclear Information System (INIS)

    Jennison, W.; Salmon, A.M.

    1978-01-01

    The machine is designed for the automatic measurement of fuel pins after irradiation in the fast reactors and is a modified version of a machine which has been in use for several years. These modifications consist of mechanical improvements and solid state control circuitry but the design criteria are unchanged. Irradiated fuel pins with diameters up to 0.875 in. are measured at fixed axial positions and angular intervals. Axial stepping of either 1 cm or 1 in. with a standard deviation of 5 x 10 -4 in. and angular rotation by multiples of 18 0 with a non-cumulative error of 1 0 can be selected. Data on axial position to 0.1 in. or 0.1 cm and fuel element diameter to 5 x 10 -5 in. are both punched and printed out for computer evaluation. The standard deviation of a single measurement on cylindrical specimens with an eccentricity of up to at least 0.1 in. should be no worse than 1 x 10 -4 in. No operator attention is required after the pin is positioned in the machine and 40 sets of 10 diameter readings at 36 0 intervals can be performed in an hour. Switches can be set between 1 and 99 to terminate an examination when power is switched off with the machine in its rest position. (author)

  13. Properties of 8-inch photomultiplier tubes for a large volume imaging water Cerenkov detector

    International Nuclear Information System (INIS)

    Oehler, Ch.

    1996-01-01

    In the Institut fuer Kernphysik I conceptional studies for a possible succession project for the KARMEN-ν-detector are performed. This design studies propose to build a large volume 1300 t imaging water Cerenkov detector. The main goal of this experiment will be the investigation of ν-e - -scattering in the medium energy range up to 50 MeV. The sensitive surface of this detector will be instrumented with about 3000 8-inch photomultiplier tubes (PMT) providing a coverage of 20%. In the framework of this detector design, studies of the properties of hemispherical 8-inch phototubes have been investigated in this work. The topic was to optimise the quality of the important PMT properties like time- and energy-resolution which are crucial to achieve the required spatial and angular resolutions. A second task of this work was to construct a test facility for the PMT, with the possibility to test large quantities. Monte Carlo calculations show that the required detector resolutions of σ E /E(E e ≤50 MeV)=5.2%+47%/√E, σ t (E e ∼30 MeV)=0.6 ns, σ x (E e ∼30 MeV)=13 cm, σ Θ (E e ∼30 MeV)=20 , can be achieved if the phototubes have a transit-time spread less than 1 ns. Up to now, two different 8-inch tubes are available and have been tested, the HAMAMATSU R5912 and the EMI 9353. (orig.)

  14. Photometric Typing Analyses of Three Young Supernovae with the Robotic Palomar 60-Inch Telescope

    OpenAIRE

    Rajala, Anne M.; Fox, Derek B.; Gal-Yam, Avishay; Leonard, Douglas C.; Soderberg, Alicia M.; Kulkarni, S. R.; Cenko, S. Bradley; Moon, Dae-Sik; Harrison, Fiona A.

    2004-01-01

    We present photometric typing analyses of three young supernovae observed with the Robotic 60-inch Telescope at Palomar Observatory (P60). This represents the first time that such photo-typing has been attempted, in a blind fashion, on newly-discovered supernovae. For one of the target supernovae, SN2004cs, our photometry provided the first constraint on the SN type, which we predicted would be type Ia. To the contrary, however, our subsequent Keck spectroscopy shows it to be an unusual type ...

  15. Nanomanipulation of 2 inch wafer fabrication of vertically aligned carbon nanotube arrays by nanoimprint lithography

    DEFF Research Database (Denmark)

    Bu, Ian Y. Y.; Eichhorn, Volkmar; Carlson, Kenneth

    2011-01-01

    Carbon nanotube (CNT) arrays are typically defined by electron beam lithography (EBL), and hence limited to small areas due to the low throughput. To obtain wafer‐scale fabrication we propose large area thermal nanoimprint lithography (NIL). A 2‐inch stamp master is defined using EBL for subsequent......, efficient production of wafer‐scale/larger arrays of CNTs has been achieved. The CNTs have been deposited by wafer‐scale plasma enhanced chemical vapour deposition (PECVD) of C2H2/NH3. Substrates containing such nanotubes have been used to automate nanorobotic manipulation sequences of individual CNTs...

  16. First thin AC-coupled silicon strip sensors on 8-inch wafers

    Energy Technology Data Exchange (ETDEWEB)

    Bergauer, T., E-mail: thomas.bergauer@oeaw.ac.at [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Dragicevic, M.; König, A. [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Hacker, J.; Bartl, U. [Infineon Technologies Austria AG, Siemensstrasse 2, 9500 Villach (Austria)

    2016-09-11

    The Institute of High Energy Physics (HEPHY) in Vienna and the semiconductor manufacturer Infineon Technologies Austria AG developed a production process for planar AC-coupled silicon strip sensors manufactured on 200 μm thick 8-inch p-type wafers. In late 2015, the first wafers were delivered featuring the world's largest AC-coupled silicon strip sensors. Detailed electrical measurements were carried out at HEPHY, where single strip and global parameters were measured. Mechanical studies were conducted and the long-term behavior was investigated using a climate chamber. Furthermore, the electrical properties of various test structures were investigated to validate the quality of the manufacturing process.

  17. Elemental Water Impact Test: Phase 2 36-Inch Aluminum Tank Head

    Science.gov (United States)

    Vassilakos, Gregory J.

    2014-01-01

    Spacecraft are being designed based on LS-DYNA simulations of water landing impacts. The Elemental Water Impact Test (EWIT) series was undertaken to assess the accuracy of LS-DYNA water impact simulations. EWIT Phase 2 featured a 36-inch aluminum tank head. The tank head was outfitted with one accelerometer, twelve pressure transducers, three string potentiometers, and four strain gages. The tank head was dropped from heights of 1 foot and 2 feet. The focus of this report is the correlation of analytical models against test data. As a measure of prediction accuracy, peak responses from the baseline LS-DYNA model were compared to peak responses from the tests.

  18. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  19. High-Volume Production of Lightweight, Multi-Junction Solar Cells Using 6-inch GaAs, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In the proposed Phase II program, we will transition MicroLink's 6-inch epitaxial lift-off (ELO) solar cell fabrication process into a manufacturing platform capable...

  20. Directed growth of diameter-tunable nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Birol; Talukdar, Ishan; Flanders, Bret N [Department of Physics, Oklahoma State University, 145 Physical Sciences II, Stillwater, OK 74078 (United States)

    2007-09-12

    This study characterizes a method for controlling the nanowire diameter in the directed electrochemical nanowire assembly technique, where alternating voltages applied to electrodes in simple salt solutions induce the crystallization of metallic wires. Dendritic solidification is identified as an important component of this technique. A characteristic of dendritic solidification is that the growth velocity and tip radius are anti-correlated. This relationship is exploited here to realize diameter-tunable nanowire growth. The experimental parameter that provides this control is {omega}, the frequency of the alternating voltage. Increasing {omega} effectively steepens the metal cation concentration gradient at the wire-solution interface, thereby increasing the growth velocity of the wire. For indium wires, increasing {omega} from 0.5 to 3.5 MHz increases their growth velocity from 11 to 78 {mu}m s{sup -1} and reduces their diameter from 770 to 114 nm. Gold wires exhibit diameter-tunability that ranges from 150 nm to 45 nm. Thus, it is possible to tune the wire diameter from the microscale down to the nanoscale. Moreover, this control is a consequence of non-stationary dendritic growth, which distinguishes this process from most previously studied examples of dendritic solidification.

  1. Recommendations for protecting against failure by brittle fracture: Category II and III ferritic steel shipping containers with wall thickness greater than four inches

    International Nuclear Information System (INIS)

    Schwartz, M.W.; Fischer, L.E.

    1996-08-01

    This report provides criteria for selecting ferritic steels that would prevent brittle fracture in Category II and III shipping containers with wall thickness greater than 4 inches. These methods are extensions of those previously used for Category II and III containers less than 4 inches thick and Category I containers more than 4 inches thick

  2. A new alignment procedure for the South African Astronomical Observatory's 74-inch telescope

    Science.gov (United States)

    Crause, Lisa A.; Booth, John A.; Doss, David; Loubser, Egan; O'Connor, James E.; Sass, Craig; Sickafoose, Amanda A.; Worters, Hannah L.

    2016-07-01

    Considerable effort has gone into improving the performance and reliability of the SAAO's 74-inch telescope. This included replacing the telescope encoders, refining the pointing model and increasing the telescope throughput. The latter involved re-aluminising the primary and formulating a procedure to ensure optimal alignment of the telescope mirrors. To this end, we developed the necessary hardware and techniques to ensure that such alignment is achieved and maintained, particularly following re-aluminising of the mirrors. In essence, the procedure involves: placing a Taylor Hobson Alignment Telescope on the mechanical rotation axis of the 74-inch (which we define to be the optical axis, since the Cassegrain instruments attach to the associated turntable), then adjusting the tip/tilt of the secondary mirror to get it onto that axis and, lastly, adjusting the tip/tilt of the primary mirror to eliminate coma. An eyepiece (or wavefront camera) is installed at the Cassegrain port for this final step since comatic star images indicate the need to tip/tilt the primary mirror to align it to the secondary. Tuning out any brightness gradients seen in an out-of-focus image of a bright star may also be used for feedback when adjusting the tip/tilt of the primary mirror to null coma.

  3. Artist autonomy in a digital era: The case of Nine Inch Nails

    Directory of Open Access Journals (Sweden)

    Steven C. Brown

    2012-09-01

    Full Text Available A 2009 presentation by Michael Masnick (CEO and founder of insight company Floor64 entitled ‘How Trent Reznor and Nine Inch Nails represent the Future of the Music Business’ brought the success of the business models employed by Reznor in distributing Nine Inch Nails’ music into the spotlight. The present review provides a comprehensive timeline of the band circa 2005-2010, evaluating the success of the distribution methods employed in accordance with Masnick’s (2009 proposed business model of connecting with fans and providing them with a reason to buy. The model is conceptualised in the wider context in which Reznor’s distribution methods take place (including a brief consideration of Radiohead’s much cited pay-what-you- want model, addressing the perceived gaps in the model by exploring the involvement of musical preferences; age and consumer purchasing behavior and fan worship. Implications are discussed concerning the applicability of the model for new and emerging bands.

  4. Solids Accumulation Scouting Studies

    Energy Technology Data Exchange (ETDEWEB)

    Duignan, M. R.; Steeper, T. J.; Steimke, J. L.

    2012-09-26

    the solids mounds. The mounds were scanned after tank supernatant was removed. 4. Core sampler to determine the stainless steel solids distribution within the solids mounds. This sampler was designed and built to remove small sections of the mounds to evaluate concentrations of the stainless steel solids at different special locations. 5. Computer driven positioner that placed the laser rangefinders and the core sampler in appropriate locations over solids mounds that accumulated on the bottom of a scaled staging tank where mixing is poor. These devices and techniques were effective to estimate the movement, location, and concentrations of the solids representing heavier particles and could perform well at a larger scale The experiment contained two campaigns with each comprised of ten cycles to fill and empty the scaled staging tank. The tank was filled without mixing, but emptied, while mixing, in seven batches; the first six were of equal volumes of 13.1 gallons each to represent the planned fullscale batches of 145,000 gallons, and the last, partial, batch of 6.9 gallons represented a full-scale partial batch of 76,000 gallons that will leave a 72-inch heel in the staging tank for the next cycle. The sole difference between the two campaigns was the energy to mix the scaled staging tank, i.e., the nozzle velocity and jet rotational speed of the two jet pumps. Campaign 1 used 22.9 ft/s, at 1.54 rpm based on past testing and Campaign 2 used 23.9 ft/s at 1.75 rpm, based on visual observation of minimum velocity that allowed fast settling solids, i.e., sand and stainless steel, to accumulate on the scaled tank bottom.

  5. Numerical simulation of two-phase slug flow with liquid carryover in different diameter ratio T-junction

    Science.gov (United States)

    Pao, W.; Hon, L.; Saieed, A.; Ban, S.

    2017-10-01

    A smaller diameter conduit pointing at 12 o’clock position is typically hot-tapped to a horizontal laying production header in offshore platform to tap produced gas for downstream process train. This geometric feature is commonly known as T-junction. The nature of multiphase fluid splitting at the T-junction is a major operational challenge due to unpredictable production environment. Often, excessive liquid carryover occurs in the T-junction, leading to complete platform trip and halt production. This is because the downstream process train is not designed to handle excessive liquid. The objective of this research is to quantify the effect of different diameter ratio on phase separation efficiency in T-junction. The liquid carryover is modelled as two-phase air-water flow using Eulerian Mixture Model coupled with Volume of Fluid Method to mimic the slug flow in the main pipe. The focus in this paper is 0.0254 m (1 inch) diameter horizontal main arm and vertical branch arm with diameter ratio of 1.0, 0.5 and 0.3. The present research narrowed the investigation to only slug flow regime using Baker’s map as reference. The investigation found that, contrary to common believe, smaller diameter ratio T-junction perform worse than larger diameter ratio T-junction.

  6. Height - Diameter predictive equations for Rubber (Hevea ...

    African Journals Online (AJOL)

    BUKOLA

    The importance of calibrating models on height-diameter relationship can never be over emphasized in predicting mean ... parameters that variously important in forest growth modeling and many sustainable forest management options(e.g., Van ..... Natural forest Ecosystem, southwest Nigeria. Research Journal of Forestry ...

  7. Liquid-vapor rectilinear diameter revisited

    Science.gov (United States)

    Garrabos, Y.; Lecoutre, C.; Marre, S.; Beysens, D.; Hahn, I.

    2018-02-01

    In the modern theory of critical phenomena, the liquid-vapor density diameter in simple fluids is generally expected to deviate from a rectilinear law approaching the critical point. However, by performing precise scannerlike optical measurements of the position of the SF6 liquid-vapor meniscus, in an approach much closer to criticality in temperature and density than earlier measurements, no deviation from a rectilinear diameter can be detected. The observed meniscus position from far (10 K ) to extremely close (1 mK ) to the critical temperature is analyzed using recent theoretical models to predict the complete scaling consequences of a fluid asymmetry. The temperature dependence of the meniscus position appears consistent with the law of rectilinear diameter. The apparent absence of the critical hook in SF6 therefore seemingly rules out the need for the pressure scaling field contribution in the complete scaling theoretical framework in this SF6 analysis. More generally, this work suggests a way to clarify the experimental ambiguities in the simple fluids for the near-critical singularities in the density diameter.

  8. Maximum Diameter of Impacting Liquid Droplets

    NARCIS (Netherlands)

    Laan, N.; de Bruin, K.G.; Bartolo, D.; Josserand, C.; Bonn, D.

    2014-01-01

    The maximum diameter a droplet that impacts on a surface will attain is the subject of controversy, notably for high-velocity impacts of low-viscosity liquids such as water or blood. We study the impact of droplets of simple liquids of different viscosities, and a shear-thinning complex fluid

  9. Photoacoustic determination of blood vessel diameter

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Klaessens, John H.G.M.; Hondebrink, Erwin; Hopman, Jeroen C.W.; de Mul, F.F.M.; Steenbergen, Wiendelt; Thijssen, Johan M.; van Leeuwen, Ton

    2004-01-01

    A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-topeak time (τ pp) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual vessel

  10. Diameter preserving linear maps and isometries, II

    Indian Academy of Sciences (India)

    We study linear bijections of simplex spaces A ( S ) which preserve the diameter of the range, that is, the seminorm ϱ ( f ) = sup { | f ( x ) − f ( y ) | : x , y ∈ S } . Author Affiliations. Félix Cabello Sánchez1. Departamento de Matemáticas, Universidad de Extremadura, Avenida de Elvas 06071- Badajoz, Spain. Dates. Manuscript ...

  11. Tannins gravimetric yield condensed in Anadenanthera peregrina bark in different diameter classes

    Directory of Open Access Journals (Sweden)

    Caroline Junqueira Sartori

    2014-06-01

    Full Text Available This work aimed to determine the gravimetric yield of condensed tannins in the Anadenanthera peregrina bark in different diameter classes. Fifty-nine trees samples were collected of Anadenanthera peregrina, at 1.30m of the ground (diameter at breast height - DBH, distributed in seven diameter classes. The barks were dried and crushed in mill of hammer. Composite sample was made to prepare the extract. The extraction was done using water in the ratio 15:1 (v/w, added 3% sodium sulfite (w/w in water-bath at 70°C for 4 hours. The material was filtered using fine cloth strainer and concentrated on a heating plate at approximately 150 g. It was determined the extract mass and removed 10 g for obtaining solids content and 20g for the Stiasny's index. The average values of total solids content, Stiasny's index, condensed tannin content and the compound content non-tannin were 11.34%; 75.79%; 12.76% and 4.07%, respectively. The content of solids, Stiasny's index, compound content non-tannin show significant differences between diameter classes. For the condensed tannins production, the diameter class parameter there was no influence.

  12. FDG gamma camera PET equipped with one inch crystal and XCT. Assessment of myocardial viability

    Energy Technology Data Exchange (ETDEWEB)

    Beheshti, M. [Dept. of Nuclear Medicine, Medical Univ., General Hospital of Vienna (Austria); Dept. of Nuclear Medicine and Endocrinology, PET CT Centre, St. Vincent' s Hospital, Linz (Austria); Khorsand, A.; Graf, S. [Dept. of Cardiology, Medical Univ., General Hospital of Vienna (Austria); Dobrozemsky, G. [Dept. of Nuclear Medicine, Medical Univ. of Innsbruck (Austria); Oezer, S.; Kletter, K.; Dudczak, R. [Dept. of Nuclear Medicine, Medical Univ., General Hospital of Vienna (Austria); Pirich, C. [Dept. of Nuclear Medicine und Endocrinology, Paracelsus Private Medical Univ., SALK, Salzburg (Austria)

    2006-07-01

    Metabolic imaging with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) is actually considered as the best method to detect and quantitatively assess myocordial tissue viability. The aim of this study was to investigate the accuracy of FDG gamma camera positron emission tomography (GCPET) imaging equipped with one inch NaI crystals in comparison to FDG dedicated PET (dPET) imaging as a ''gold standard'' in phantom and clinical studies. Patients, methods: nineteen patients with coronary artery disease (CAD) underwent both imaging modalities. Phantom and clinical GCPET imaging were performed with a dual-headed, coincidence based gamma camera equipped with 1 inch thick NaI crystals and an X-ray tube (XCT) for attenuation correction (AC), as well as with a dedicated PET scanner with AC. {sup 99m}Tc tetrofosmin single-photon emission tomography (SPET) studies were performed for assessment of myocardial perfusion, with AC. Results: phantom studies showed a significant relation in segmental activity between FDG imaging with AC using GCPET and dPET (r = 0.91, p < 0.001). In clinical studies with AC correlation coefficients of mean segmental FDG uptake and regional defect size were r = 0.87 (p < 0.0001) and r = 0.83 (p < 0.0001), respectively. In regional analysis close agreement was even found in the most attenuated regions of the heart if AC was used in GCPET imaging. The overall agreement for detection of viable myocardium was 81% between FDG-dPET (AC) and FDG-GCPET (AC) and 74% between FDG-dPET (AC) and FDG-GCPET (NC). Conclusions: suggests that the assessment of myocardial metabolism by means of FDG is feasible with a coincidence based gamma camera equipped with 1 inch thick NaI crystal if AC is performed. The results reveal a close concordance and agreement between FDG-dPET (AC) and FDG-GCPET (AC) as compared to FDG-GCPET (NC). (orig.)

  13. Simulation of adsorber tube diameter's effect on new design silica gel-water adsorption chiller

    Science.gov (United States)

    Nasruddin, Taufan, A.; Manga, A.; Budiman, D.

    2017-03-01

    A new design of silica gel-water adsorption chiller is proposed. The design configuration is composed of two sorption chambers with compact fin tube heat exchangers as adsorber, condenser, and evaporator. Heat and mass recovery were adopted in order to increase the cooling capacity. Numerical modelling and calculation were used to show the performance of the chiller with different adsorber tube diameter. Under typical condition for hot water inlet/cooling water inlet/chilled water outlet temperatures are 90/30/7°C, respectively, the simulation results showed the best average value of COP, SCP, and cooling power are 0.19, 15.88 W/kg and 279.89 W using 3/8 inch tube.

  14. Testing of one-inch UF{sub 6} cylinder valves under simulated fire conditions

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, P.G. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Accurate computational models which predict the behavior of UF{sub 6} cylinders exposed to fires are required to validate existing firefighting and emergency response procedures. Since the cylinder valve is a factor in the containment provided by the UF{sub 6} cylinder, its behavior under fire conditions has been a necessary assumption in the development of such models. Consequently, test data is needed to substantiate these assumptions. Several studies cited in this document provide data related to the behavior of a 1-inch UF{sub 6} cylinder valve in fire situations. To acquire additional data, a series of tests were conducted at the Paducah Gaseous Diffusion Plant (PGDP) under a unique set of test conditions. This document describes this testing and the resulting data.

  15. Recent developments in high charge state heavy ion beams at the LBL 88-inch Cyclotron

    International Nuclear Information System (INIS)

    Gough, R.A.; Clark, D.J.; Glasgow, L.R.

    1978-01-01

    Recent advances in design and operation of the internal PIG sources at the LBL 88-Inch Cyclotron have led to the development of high charge state (0.4 16 O 8+ . Total external intensities of these beams range from 10 12 particles/s for 6 Li 3+ to 0.1 particles/s for 16 O 8+ . Techniques have been developed for routine tune-out of the low intensity beams. These include use of model beams and reliance on the large systematic data base of cyclotron parameters which has been developed over many years of operation. Techniques for delivery of these weak beams to the experimental target areas are presented. Source design and operation, including special problems associated with Li, Be, and B beams are discussed

  16. LOFT transient thermal analysis for 10 inch primary coolant blowdown piping weld

    International Nuclear Information System (INIS)

    Howell, S.K.

    1978-01-01

    A flaw in a weld in the 10 inch primary coolant blowdown piping was discovered by LOFT personnel. As a result of this, a thermal analysis and fracture mechanics analysis was requested by LOFT personnel. The weld and pipe section were analyzed for a complete thermal cycle, heatup and Loss of Coolant Experiment (LOCE), using COUPLE/MOD2, a two-dimensional finite element heat conduction code. The finite element representation used in this analysis was generated by the Applied Mechanics Branch. The record of nodal temperatures for the entire transient was written on tape VSN=T9N054, and has been forwarded to the Applied Mechanics Branch for use in their mechanical analysis. Specific details and assumptions used in this analysis are found in appropriate sections of this report

  17. Development and characterization of a CCD camera system for use on six-inch manipulator systems

    International Nuclear Information System (INIS)

    Logory, L.M.; Bell, P.M.; Conder, A.D.; Lee, F.D.

    1996-01-01

    The Lawrence Livermore National Laboratory has designed, constructed, and fielded a compact CCD camera system for use on the Six Inch Manipulator (SIM) at the Nova laser facility. The camera system has been designed to directly replace the 35 mm film packages on all active SIM-based diagnostics. The unit's electronic package is constructed for small size and high thermal conductivity using proprietary printed circuit board technology, thus reducing the size of the overall camera and improving its performance when operated within the vacuum environment of the Nova laser target chamber. The camera has been calibrated and found to yield a linear response, with superior dynamic range and signal-to-noise levels as compared to T-Max 3200 optic film, while providing real-time access to the data. Limiting factors related to fielding such devices on Nova will be discussed, in addition to planned improvements of the current design

  18. Coke from small-diameter tubes analyzed

    International Nuclear Information System (INIS)

    Albright, L.F.

    1988-01-01

    The mechanism for coke deposit formation and the nature of the coke itself can vary with the design of the ethylene furnace tube bank. In this article, coke deposits from furnaces with small-diameter pyrolysis tubes are examined. The samples were taken from four furnaces of identical design (Plant B). As in both the first and second installments of the series, the coke deposits were examined using a scanning electron microscope (SEM) and an energy dispersive X-ray analyzer (EDAX). The deposits from the small-diameter tubes are compared with the coke deposits from the furnace discussed in earlier articles. Analysis of the coke in both sets of samples are then used to offer recommendations for improved decoking procedures, operating procedures, better feed selection, and better selection of the metallurgy used in furnace tubes, to extend the operating time of the furnace tubes by reducing the amount and type of coke build up

  19. On finding minimum-diameter clique trees

    Energy Technology Data Exchange (ETDEWEB)

    Blair, J.R.S. (Tennessee Univ., Knoxville, TN (United States). Dept. of Computer Science); Peyton, B.W. (Oak Ridge National Lab., TN (United States))

    1991-08-01

    It is well-known that any chordal graph can be represented as a clique tree (acyclic hypergraph, join tree). Since some chordal graphs have many distinct clique tree representations, it is interesting to consider which one is most desirable under various circumstances. A clique tree of minimum diameter (or height) is sometimes a natural candidate when choosing clique trees to be processed in a parallel computing environment. This paper introduces a linear time algorithm for computing a minimum-diameter clique tree. The new algorithm is an analogue of the natural greedy algorithm for rooting an ordinary tree in order to minimize its height. It has potential application in the development of parallel algorithms for both knowledge-based systems and the solution of sparse linear systems of equations. 31 refs., 7 figs.

  20. Elaboration of building materials from industrial waste from solid granular diatomaceous earth

    International Nuclear Information System (INIS)

    Del Angel S, A.

    2015-01-01

    In this work the initial characterization of granular solid industrial waste from diatomaceous earth was carried out using techniques of Scanning Electron Microscopy and X-ray Diffraction. In a second stage leaching of the material was undertaken to the US Patent Number 5, 376,000 and 5, 356,601 obtaining the samples M1-S ph 2, M1-L ph, M1-S ph 10 and M1-L ph 10. In the third stage a new characterization of the samples obtained with the techniques of Scanning Electron Microscopy, X-ray Diffraction and Atomic Absorption Spectrometry was performed, the latter in order to determine the efficiency percentage of the leaching process. In the fourth stage the specimens for performing mechanical, physical and chemical tests were manufactured, using molds as PVC pipes of 1 inch in diameter and 2 inches in length, with a composition of 50% of diatomaceous earth and 50% of cement produced in each. Finally, in the fifth stage mechanical testing (compression resistance), physical (moisture absorption rate) and chemical (composition and structure of the material) are performed. In the last stage, when conducting mechanical testing with the test specimens, the presence of bubbles enclosed in each obtaining erroneous results noted, so it was necessary to develop the specimens again, obtaining in this occasion concentrations of 20:80, 40:60, 60:40 and 80:20 of diatomaceous earth with the cement. These results were analyzed to determine if the used material is suitable for the production of building materials such as bricks or partitions, being demonstrated by the tests carried out if they are eligible. (Author)

  1. Prediction of Ablation Rates from Solid Surfaces Exposed to High Temperature Gas Flow

    Science.gov (United States)

    Akyuzlu, Kazim M.; Coote, David

    2013-01-01

    ablation. Two different ablation models are proposed to determine the heat loss from the solid surface due to the ablation of the solid material. Both of them are physics based. Various numerical simulations were carried out using both models to predict the temperature distribution in the solid and in the gas flow, and then predict the ablation rates at a typical NTR motor hydrogen gas temperature and pressure. Solid mass loss rate per foot of a pipe was also calculated from these predictions. The results are presented for fully developed turbulent flow conditions in a sample SS pipe with a 6 inch diameter.

  2. Fast and robust shape diameter function.

    Science.gov (United States)

    Chen, Shuangmin; Liu, Taijun; Shu, Zhenyu; Xin, Shiqing; He, Ying; Tu, Changhe

    2018-01-01

    The shape diameter function (SDF) is a scalar function defined on a closed manifold surface, measuring the neighborhood diameter of the object at each point. Due to its pose oblivious property, SDF is widely used in shape analysis, segmentation and retrieval. However, computing SDF is computationally expensive since one has to place an inverted cone at each point and then average the penetration distances for a number of rays inside the cone. Furthermore, the shape diameters are highly sensitive to local geometric features as well as the normal vectors, hence diminishing their applications to real-world meshes which often contain rich geometric details and/or various types of defects, such as noise and gaps. In order to increase the robustness of SDF and promote it to a wide range of 3D models, we define SDF by offsetting the input object a little bit. This seemingly minor change brings three significant benefits: First, it allows us to compute SDF in a robust manner since the offset surface is able to give reliable normal vectors. Second, it runs many times faster since at each point we only need to compute the penetration distance along a single direction, rather than tens of directions. Third, our method does not require watertight surfaces as the input-it supports both point clouds and meshes with noise and gaps. Extensive experimental results show that the offset-surface based SDF is robust to noise and insensitive to geometric details, and it also runs about 10 times faster than the existing method. We also exhibit its usefulness using two typical applications including shape retrieval and shape segmentation, and observe a significant improvement over the existing SDF.

  3. Rapid construction of Pacific Street Bridge with o.7 inch strands.

    Science.gov (United States)

    2010-10-01

    The Pacific Street Bridge over I-680 in Omaha, NE is the first bridge in the United States to use 0.7-in.-diameter prestressing : strands in pretensioned concrete girders. This project was funded by FHWA through NDOR under the Innovative Bridge Resea...

  4. 29 mm Diameter Target Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Olivas, Eric Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Naranjo, Angela Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-10-23

    After numerous delays, the test of the 29 mm diameter target was conducted on 8/18/2017. The complete target design report, dated 8/15/2016, is reproduced below for completeness. This describes in detail the 10 disk target with varying thickness disks. The report presents and discusses the test results. In brief summary, there appears to have been multiple instrumentation errors. Measured temperatures, pressures and IR camera window temperature measurement are all suspect. All tests were done at 35 MeV, with 171 μA current, or 6 kW of beam power.

  5. Sagittal Abdominal Diameter: Application in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Thaís Da Silva-Ferreira

    2014-05-01

    Full Text Available Excess visceral fat is associated with cardiovascular risk factors. Sagittal abdominal diameter (SAD has recently been highlighted as an indicator of abdominal obesity, and also may be useful in predicting cardiovascular risk. The purpose of the present study was to review the scientific literature on the use of SAD in adult nutritional assessment. A search was conducted for scientific articles in the following electronic databases: SciELO , MEDLINE (PubMed and Virtual Health Library. SAD is more associated with abdominal fat (especially visceral, and with different cardiovascular risk factors, such as, insulin resistance, blood pressure, and serum lipoproteins than the traditional methods of estimating adiposity, such as body mass index and waist-to-hip ratio. SAD can also be used in association with other anthropometric measures. There are still no cut-off limits established to classify SAD as yet. SAD can be an alternative measure to estimate visceral adiposity. However, the few studies on this diameter, and the lack of consensus on the anatomical site to measure SAD, are obstacles to establish cut-off limits to classify it.

  6. The Berkeley accelerator space effects facility (BASE) - A newmission for the 88-inch cyclotron at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, M.A.

    2005-09-06

    In FY04, the 88-Inch Cyclotron began a new operating mode that supports a local research program in nuclear science, R&D in accelerator technology and a test facility for the National Security Space (NSS) community (the U.S. Air Force and NRO). The NSS community (and others on a cost recovery basis) can take advantage of both the light- and heavy-ion capabilities of the Cyclotron to simulate the space radiation environment. A significant portion of this work involves the testing of microcircuits for single event effects. The experimental areas within the building that are used for the radiation effects testing are now called the Berkeley Accelerator and Space Effects (BASE) facility. Improvements to the facility to provide increased reliability, quality assurance and new capabilities are underway and will be discussed. These include a 16 AMeV ''cocktail'' of beams for heavy ion testing, a neutron beam, more robust dosimetry, and other upgrades.

  7. Design evaluation of the 20-cm (8-inch) secondary burner system

    Energy Technology Data Exchange (ETDEWEB)

    Rode, J.S.

    1977-08-01

    This report describes an evaluation of the design of the existing 20-cm (8-inch) engineering-scale secondary burner system in the HTGR reprocessing cold pilot plant at General Atomic Co. The purpose of this evaluation is to assess the suitability of the existing design as a prototype of the HTGR Recycle Demonstration Facility (HRDF) secondary burner system and to recommend alternatives where the existing design is thought to be unsuitable as a prototype. This evaluation has led to recommendations for the parallel development of two integrated design concepts for a prototype secondary burner system. One concept utilizes the existing burner heating and cooling subsystems in order to minimize development risk, but simplifies a number of other features associated with remote maintenance and burner operation. The other concept, which offers maximum cost reduction, utilizes internal gas cooling of the burner, retains the existing heating subsystem for design compatibility, but requires considerable development to reduce the risk to acceptable limits. These concepts, as well as other design alternatives, are described and evaluated.

  8. Experimental performance of an internal resistance heater for Langley 6-inch expansion tube driver

    Science.gov (United States)

    Creel, T. R., Jr.

    1972-01-01

    An experimental investigation of the heating characteristics of an internal resistance heating element was conducted in the driver of the Langley 6-inch expansion tube to obtain actual operating conditions, to compare these results to theory, and to determine whether any modification need be made to the heater element. The heater was operated in pressurized helium from 138. MN/sq m to 62.1 MN/sq m. This investigation revealed large temperature variations within the heater element caused primarily by area reductions at insulator locations. These large temperature variations were reduced by welding small tabs over all grooves. Previous predictions of heater element and driver gas temperature were unacceptable so new equations were derived. These equations predict element and gas temperature within 10 percent of the test data when either the constant power cycle or the interrupted power cycle is used. Visual observation of the heater element, when exposed to the atmosphere with power on, resulted in a decision to limit the heater element to 815 K. Experimental shock Mach numbers are in good agreement with theory.

  9. Summary of LaRC 2-inch Erectable Joint Hardware Heritage Test Data

    Science.gov (United States)

    Dorsey, John T.; Watson, Judith J.

    2016-01-01

    As the National Space Transportation System (STS, also known as the Space Shuttle) went into service during the early 1980's, NASA envisioned many missions of exploration and discovery that could take advantage of the STS capabilities. These missions included: large orbiting space stations, large space science telescopes and large spacecraft for manned missions to the Moon and Mars. The missions required structures that were significantly larger than the payload volume available on the STS. NASA Langley Research Center (LaRC) conducted studies to design and develop the technology needed to assemble the large space structures in orbit. LaRC focused on technology for erectable truss structures, in particular, the joint that connects the truss struts at the truss nodes. When the NASA research in large erectable space structures ended in the early 1990's, a significant amount of structural testing had been performed on the LaRC 2-inch erectable joint that was never published. An extensive set of historical information and data has been reviewed and the joint structural testing results from this historical data are compiled and summarized in this report.

  10. Design evaluation of the 20-cm (8-inch) secondary burner system

    International Nuclear Information System (INIS)

    Rode, J.S.

    1977-08-01

    This report describes an evaluation of the design of the existing 20-cm (8-inch) engineering-scale secondary burner system in the HTGR reprocessing cold pilot plant at General Atomic Co. The purpose of this evaluation is to assess the suitability of the existing design as a prototype of the HTGR Recycle Demonstration Facility (HRDF) secondary burner system and to recommend alternatives where the existing design is thought to be unsuitable as a prototype. This evaluation has led to recommendations for the parallel development of two integrated design concepts for a prototype secondary burner system. One concept utilizes the existing burner heating and cooling subsystems in order to minimize development risk, but simplifies a number of other features associated with remote maintenance and burner operation. The other concept, which offers maximum cost reduction, utilizes internal gas cooling of the burner, retains the existing heating subsystem for design compatibility, but requires considerable development to reduce the risk to acceptable limits. These concepts, as well as other design alternatives, are described and evaluated

  11. Development of the Software for 30 inch Telescope Control System at KHAO

    Science.gov (United States)

    Mun, B.-S.; Kim, S.-J.; Jang, M.; Min, S.-W.; Seol, K.-H.; Moon, K.-S.

    2006-12-01

    Even though 30inch optical telescope at Kyung Hee Astronomy Observatory has been used to produce a series of scientific achievements since its first light in 1992, numerous difficulties in the operation of the telescope have hindered the precise observations needed for further researches. Since the currently used PC-TCS (Personal Computer based Telescope Control system) software based on ISA-bus type is outdated, it doesn't have a user friendly interface and make it impossible to scale. Also accumulated errors which are generated by discordance from input and output signals into a motion controller required new control system. Thus we have improved the telescope control system by updating software and modifying mechanical parts. We applied a new BLDC (brushless DC) servo motor system to the mechanical parts of the telescope and developed a control software using Visual Basic 6.0. As a result, we could achieve a high accuracy in controlling of the telescope and use the userfriendly GUI (Graphic User Interface).

  12. Simultaneous SO[sub 2]/NO/particulate removal from coal combustion gas by solid-state electrochemical technology

    Energy Technology Data Exchange (ETDEWEB)

    Cornell, L.P.; Cook, W.J.; Keyvani, M.; Neyman, M. (Helipump Corp., Cleveland, OH (United States)); Helfritch, D.J. (Research-Cottrell, Inc., Somerville, NJ (United States). Environmental Services and Technologies Div.)

    1991-01-21

    A solid-state electrochemical process now in an early stage of development converts NO[sub x]and SO[sub x] to nitrogen, oxygen, and sulfur. Process objectives are to remove 90+% of SO[sub x] and NO[sub x] and 99% of particulates from Ohio coal combustion flue gases. The electrochemical reactor cell uses ionically conductive ceramics as electrolyte, and electronically conductive materials (including some ceramics) as electrodes; there are no moving parts, no consumable reagents, no by-product sludges, and no process fluids except the flue gas. Downstream of the electro-chemical cell, particulates are removed with a filter or electrostatic precipitator and elemental sulfur is condensed. This work developed and tested electrocatalysts for their ability to selectively reduce SO[sub 2] and NO[sub x] in the presence of oxygen gas in concentrations typical of coal combustion flue gases. Several solid electrolytes and various electrode materials were also tested for use in the electrochemical cell. Gold was chosen as the electrode in the tests because it is porous, resistant to chemical attack, and conductive. Electrocatalyst coatings containing a single transition metal were applied to one inch diameter yttria stabilized ceria disks and tested for NO and SO[sub 2] reduction.

  13. Buckling Test Results and Preliminary Test and Analysis Correlation from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA02

    Science.gov (United States)

    Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.; Thornburgh, Robert P

    2017-01-01

    Results from the testing of cylinder test article SBKF-P2-CYL-TA02 (referred to herein as TA02) are presented. TA02 is an 8-foot-diameter (96-inches), 78.0-inch-long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch-vehicle structures and was designed to exhibit global buckling when subjected to combined compression and bending loads. The testing was conducted at the Marshall Space Flight Center (MSFC), February 3-6, 2009, in support of the Shell Buckling Knockdown Factor Project (SBKF). The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF researchers.

  14. INVESTIGATION OF 3-INCH/70 CARTRIDGES FROM AMMUNITION LOT PV-4-C-57

    Science.gov (United States)

    cartridge components from the same ammunition lot , PV-4-C-57, failed to reproduce a similar preignition. It was concluded that: the cartridges from...ammunition lot PV-4-C-57 appear to be serviceable; the premature ignition, upon ramming, of a 3-in/70 cartridge probably would not be caused by solid

  15. Maximizing Drilling Performance through Enhanced Solid Control System

    Science.gov (United States)

    Irawan, S.; Kinif, B. I.; Bayuaji, R.

    2017-11-01

    High solid content in drilling mud may affect its properties and result in uncertainties at downhole condition. It eventually contributes to poor rig operation performance and operating cost. This research focus on developing solid control system that is suit for drilling 12.25-inch hole. The first part discussed the performance of Rate of Penetration (ROP), Equivalent Circulating Density (ECD) and drill string drag while the second part of the research discussed about the effect of solid control system performance to mud properties Plastic Viscosity (PV), Yield Point (YP) and Low-Gravity Solid (LGS). The input parameters were gathered from two different set up of solid control systems that were used in Well A and Well B. The result is mainly based on the performance of original solid control system new design versus old design. Installation of distributor tank and channel the mud to respective shale shakers significantly enhanced the system and operational performance. The ROP at 12.25-inch drilling were improved by 20%. New design improved average the ECD margin by reducing additional pressure exerted using original mud from 4.9% to 2.9%. High ECD margin is not recommended because it can break the weak formation. Mud properties while drilling the 12.25-inch hole section; PV, YP and LGS values were improved by 14 %, 17 % and 25 % respectively. Proper mud flow control and routing system at new develop design of solid control system effectively removed the solid in the drilling fluid. This improvement minimizes the tendency of frequent mud flow, screen mesh plugging and tool wear issue. Mud properties such PV, YP and LGS were maintained with an acceptable mud design envelope.

  16. Development of Erosive Burning Models for CFD Predictions of Solid Rocket Motor Internal Environments

    Science.gov (United States)

    Wang, Qun-Zhen

    2003-01-01

    Four erosive burning models, equations (11) to (14). are developed in this work by using a power law relationship to correlate (1) the erosive burning ratio and the local velocity gradient at propellant surfaces; (2) the erosive burning ratio and the velocity gradient divided by centerline velocity; (3) the erosive burning difference and the local velocity gradient at propellant surfaces; and (4) the erosive burning difference and the velocity gradient divided by centerline velocity. These models depend on the local velocity gradient at the propellant surface (or the velocity gradient divided by centerline velocity) only and, unlike other empirical models, are independent of the motor size. It was argued that, since the erosive burning is a local phenomenon occurring near the surface of the solid propellant, the erosive burning ratio should be independent of the bore diameter if it is correlated with some local flow parameters such as the velocity gradient at the propellant surface. This seems to be true considering the good results obtained by applying these models, which are developed from the small size 5 inch CP tandem motor testing, to CFD simulations of much bigger motors.

  17. Solid Matter

    CERN Document Server

    Angelo, Joseph A

    2011-01-01

    Supported by a generous quantity of full-color illustrations and interesting sidebars, Solid Matter introduces the basic characteristics and properties of solid matter. It briefly describes the cosmic connection of the elements, leading readers through several key events in human pre-history that resulted in more advanced uses of matter in the solid state. Chapters include:. -Solid Matter: An Initial Perspective. -Physical Behavior of Matter. -The Gravity of Matter. -Fundamentals of Materials Science. -Rocks and Minerals. -Metals. -Building Materials. -Carbon Earth's Most Versatile Element. -S

  18. MLEP-Fail calibration for 1/8 inch thick cast plate of 17-4 steel.

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    The purpose of the work presented in this memo was to calibrate the Sierra material model Multilinear Elastic-Plastic Hardening Model with Failure (MLEP-Fail) for 1/8 inch thick cast plate of 17-4 steel. The calibration approach is essentially the same as that recently used in a previous memo using data from smooth and notched tensile specimens. The notched specimens were manufactured with three notch radii R = 1=8, 1/32 and 1/64 inches. The dimensions of the smooth and notched specimens are given in the prints in Appendix A. Two cast plates, Plate 3 and Plate 4, with nominally identical properties were considered.

  19. Mockup Small-Diameter Air Distribution System

    Energy Technology Data Exchange (ETDEWEB)

    A. Poerschke and A. Rudd

    2016-05-01

    This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

  20. Body diameters in 3 - 6 years old children from Plovdiv

    Directory of Open Access Journals (Sweden)

    Tineshev Slavi

    2013-01-01

    Full Text Available The purpose of the research is to analyze the body diameters in 3-6 year old children. The biacromial diameters were taken as well as the two chest diameters, the bicristal and bitrohanterial diameters in 316 children (157 boys and 159 girls 3, 4, 5 and 6 years of age attending kindergarten in Plovdiv. The analysis shows that all diameters, with the exception of the bitrohanterial have higher values in boys. The absolute year's increment of the diameters is greater in girls. The growth velocity of the researched features is greatest at the age of 3-4 and 4-5, decreasing at different rates for the different features at the age of 5-6. The only exception is the sagittal chest diameter in both sexes and the bitrohanterial diameters in girls.

  1. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari, Gerard T. Pittard

    2004-01-01

    optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to the design, fabrication and testing of a entry fitting in a 4-inch prototype and is now being used to complete drawings for use in 12-inch diameter pipe. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

  2. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M Kothari; Gerard T. Pittard

    2004-07-01

    ) continued with additional in-pipe testing required to optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being manufactured. The 12-inch ball valve for allowing no-blow access was also procured. Task 8 (System Integration and Laboratory Validation) continued with the development of the robot module inter-connects and of a master LabView-based system display and control software.

  3. Lumbar Vertebral Canal Diameters in Adult Ugandan Skeletons ...

    African Journals Online (AJOL)

    The midsagittal, transverse diameters of the lumbar vertebral canal and the anteroposterior diameter of the inferior vertebral notch were measured using an electronic digital caliper. Collected data was analyzed using SPSS 12.0 computer program. Results and discussion: In both sexes, the midsagittal diameter of the canal ...

  4. Aortic Root Diameter and Longitudinal Blood Pressure Tracking

    OpenAIRE

    Ingelsson, Erik; Pencina, Michael J.; Levy, Daniel; Aragam, Jayashri; Mitchell, Gary F.; Benjamin, Emelia J.; Vasan, Ramachandran S.

    2008-01-01

    Proximal aortic diameter, including aortic root (AoR) diameter, has been inversely related to pulse pressure (PP) in cross-sectional studies. So, investigators have hypothesized that a smaller AoR diameter may increase risk of developing hypertension. Prospective studies are lacking to test this hypothesis.

  5. Solid waste

    International Nuclear Information System (INIS)

    1995-01-01

    The article drawn up within the framework of 'the assessment of the state of the environment in Lebanon' provides an overview of solid waste management, and assesses future wastes volume and waste disposal issues.In particular it addresses the following concerns: - Long term projections of solid waste arisings (i.e. domestic, industrial, such commercial wastes, vehicle types, construction waste, waste oils, hazardous toxic wastes and finally hospital and clinical wastes) are described. - Appropriate disposal routes, and strategies for reducing volumes for final disposal - Balance between municipal and industrial solid waste generation and disposal/treatment and - environmental impacts (aesthetics, human health, natural environment )of existing dumps, and the potential impact of government plans for construction of solid waste facilities). Possible policies for institutional reform within the waste management sector are proposed. Tables provides estimations of generation rates and distribution of wastes in different regions of Lebanon. Laws related to solid waste management are summarized

  6. 60-inch annular pitch polisher for LASL's LASER-fusion effort

    International Nuclear Information System (INIS)

    Williamson, R.

    1978-01-01

    The Antares laser will require that about 100 high-precision NaCl windows of 18-in. diameter be produced, maintained, and repaired. To aid the industry in achieving the required production rates, a polishing development program was undertaken by LASL's Laser Division in collaboration with the Air Force and International Laser Systems. The design and initial shakedown of the polishing machine is described. Preliminary results indicate the machine's design is sound, its operation is generally simple, and it should be capable of finishing 18-in. NaCl to better than lambda/2 visible and 20-10 surface. Shakedown work with glass has demonstrated 0-0 surface, complete absence of edge roll, and lambda/16 over 12 in., and lambda/6 over 19 in

  7. Screw fixation diameter for fifth metatarsal jones fracture: a cadaveric study.

    Science.gov (United States)

    Scott, Ryan T; Hyer, Christopher F; DeMill, Shyler L

    2015-01-01

    The fifth metatarsal Jones fracture is a well-documented injury occurring at the proximal diaphyseal-metaphyseal junction. Conservative versus surgical intervention has been discussed in published studies for the management of Jones fractures. Solid intramedullary fixation relies on accurate matching of the screw diameter to the intraosseous diameter. The purpose of the present cadaveric study was to determine the average intraosseous diameter of the proximal fifth metatarsal as it relates to screw size selection for Jones fracture stabilization. Twenty fresh-frozen cadaver legs were used for examination. The fifth metatarsal was completely dissected. A transverse osteotomy was performed from laterally to medially along the midline of the metatarsal. A digital caliper was used to measure the diameter of the medullary canal of the fifth metatarsal. The measurement was taken at the narrowest portion of the medullary canal just distal to the proximal metaphysis. The mean dorsal to plantar diameter of the fifth metatarsal was 6.475 ± 1.54 (range 4 to 12) mm and the mean medial to lateral diameter was 4.6 ± 0.85 (range 3 to 6) mm. Intramedullary screw fixation has shown beneficial results in the treatment protocol of fifth metatarsal Jones fractures. Our study has demonstrated that a 4.5-mm cannulated screw is the narrowest diameter screw that can be used in the average fifth metatarsal and still obtain adequate intraosseous purchase. When selecting the appropriate screw, the surgeon must be comfortable selecting the largest screw that will achieve the maximal interface with the dense cortical bone in both the medial to lateral and dorsal to plantar plane. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Effectiveness of catch basins equipped with hoods in retaining gross solids and hydrocarbons in highway runoff, Southeast Expressway, Boston, Massachusetts, 2008-09

    Science.gov (United States)

    Smith, Kirk P.

    2011-01-01

    Stormwater mobilizes litter and other debris along the roadway where it is transported to the highway drainage systems. Initial treatment for stormwater runoff typically is provided by catch basins in highway settings. Modification of catch basins to include hoods that cover the catch-basin outlet is intended to enhance catch-basin performance by retaining floatable debris and various hydrophobic organic compounds that tend to float on the water surface within the sump of the catch basin. The effectiveness of six deep-sump off-line catch basins equipped with hoods in reducing the mass of gross solids greater than 0.25 inches in diameter and concentrations of oil and grease (OG) and total petroleum hydrocarbons (TPH) was examined along the Southeast Expressway, in Boston, Massachusetts. Two deep-sump catch basins were equipped with cast-iron hoods. Three were equipped with molded plastic hoods, known as an Eliminator, and a single catch basin was equipped with a fiberglass anti-siphoning hood, known as a Snout. Samples of gross solids greater than 0.25 inches in diameter, excluding gravel and metallic materials, were routinely collected for a 6-month period from a collection structure mounted at the end of each catch-basin outlet pipe. After about 6 months, all floatable, saturated low-density and high-density solids were removed from each catch basin. In addition to the collection of samples of gross solids, samples of sump water from five catch basins and flow-weighted composite samples of stormwater from the outlet of one catch basin were collected and analyzed for concentrations of OG and TPH. A mass balance approach was used to assess the effectiveness of each catch basin equipped with a hood in retaining gross solids. The effectiveness of the deep-sump catch basins fitted with one of three types of hoods in retaining gross solids ranged from 27 to 52 percent. From 45 to 90 percent of the gross solids collected from the catch-basin sumps were composed of

  9. Catalytic growth of metallic tungsten whiskers based on the vapor-solid-solid mechanism

    International Nuclear Information System (INIS)

    Wang, S L; He, Y H; Huang, B Y; Zou, J; Wang, Y; Huang, H; Liu, C T; Liaw, P K

    2008-01-01

    Metallic W whiskers with tip diameters of 50-250 nm and lengths of 2-4 μm have been successfully synthesized in large quantities using Co-Ni alloyed catalysts. The relatively low growth temperature of 850 deg. C and the large catalyst size (over 100 nm) suggest that the growth of the W whiskers must be governed by the vapor-solid-solid mechanism. Our results show that the vapor-solid-solid model is suitable not only for the growth of nano-scaled whiskers with diameters below 100 nm, but also for submicro-scaled whiskers with diameters well above 100 nm. This technique has great potential to synthesize well controlled metallic whiskers

  10. The quantitative evaluation of intracranial pressure by optic nerve sheath diameter/eye diameter CT measurement.

    Science.gov (United States)

    Bekerman, Inessa; Sigal, Tal; Kimiagar, Itzhak; Ben Ely, Anna; Vaiman, Michael

    2016-12-01

    The changes of the optic nerve sheath diameter (ONSD) have been used to assess changes of the intracranial pressure for 20 years. The aim of this research was to further quantify the technique of measuring the ONSD for this purpose. Retrospective study of computed tomographic (CT) data of 1766 adult patients with intracranial hypotension (n=134) or hypertension (n=1632) were analyzed. The eyeball transverse diameter (ETD) and ONSD were obtained bilaterally, and the ONSD/ETD ratio was calculated. The ratio was used to calculate the normal ONSD for patients and to estimate the intracranial pressure of the patients before and after the onset of the pathology. Correlation analysis was performed with invasively measured intracranial pressure, the presence or absence of papilledema, sex, and age. In hypotension cases, the ONSD by CT was 3.4±0.7 mm (P=.03 against normative 4.4±0.8 mm). In cases with hypertension, the diameter was 6.9±1.3 (P=.02, with a cutoff value ˃5.5 mm). The ONSD/ETD ratio was 0.29±0.04 against 0.19±0.02 in healthy adults (P=.01). The ONSD and the ONSD/ETD ratio can indicate low intracranial pressure, but quantification is impossible at intracranial pressure less than 13 mm Hg. In elevated intracranial pressure, the ONSD and the ratio provide readings that correspond to readings in millimeters of mercury. The ONSD method, reinforced with additional calculations, may help to indicate a raised intracranial pressure, evaluate its severity quantitatively, and establish quantitative goals for treatment of intracranial hypertension, but the limitations of the method are to be taken into account. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Simultaneous SO{sub 2}/NO/particulate removal from coal combustion gas by solid-state electrochemical technology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cornell, L.P.; Cook, W.J.; Keyvani, M.; Neyman, M. [Helipump Corp., Cleveland, OH (United States); Helfritch, D.J. [Research-Cottrell, Inc., Somerville, NJ (United States). Environmental Services and Technologies Div.

    1991-01-21

    A solid-state electrochemical process now in an early stage of development converts NO{sub x}and SO{sub x} to nitrogen, oxygen, and sulfur. Process objectives are to remove 90+% of SO{sub x} and NO{sub x} and 99% of particulates from Ohio coal combustion flue gases. The electrochemical reactor cell uses ionically conductive ceramics as electrolyte, and electronically conductive materials (including some ceramics) as electrodes; there are no moving parts, no consumable reagents, no by-product sludges, and no process fluids except the flue gas. Downstream of the electro-chemical cell, particulates are removed with a filter or electrostatic precipitator and elemental sulfur is condensed. This work developed and tested electrocatalysts for their ability to selectively reduce SO{sub 2} and NO{sub x} in the presence of oxygen gas in concentrations typical of coal combustion flue gases. Several solid electrolytes and various electrode materials were also tested for use in the electrochemical cell. Gold was chosen as the electrode in the tests because it is porous, resistant to chemical attack, and conductive. Electrocatalyst coatings containing a single transition metal were applied to one inch diameter yttria stabilized ceria disks and tested for NO and SO{sub 2} reduction.

  12. Analysis of Gear Wheel-shaft Joint Characterized by Comparable Pitch Diameter and Mounting Diameter

    Directory of Open Access Journals (Sweden)

    J. Ryś

    2003-01-01

    Full Text Available This paper presents the design procedure for a gear wheel-shaft direct frictional joint. The small difference between the operating pitch diameter of the gear and the mounting diameter of the frictional joint is the key feature of the connection. The contact surface of the frictional joint must be placed outside the bottom land of the gear, and the geometry of the joint is limited to the specific type of solutions.The strength analysis is based on the relation between the torque and statistical load intensity of the gear transmission. Several dimensionless parameters are introduced to simplify the calculations. Stress-strain verifying analysis with respect to combined loading, the condition of appropriate load-carrying capacity of the frictional joint and the fatigue strength of the shaft are applied to obtain the relations between the dimensions of the joint and other parameters. The final engineering solution may then be suggested. The approach is illustrated by a numerical example.The proposed procedure can be useful in design projects for small, high-powered modern reducers and new-generation geared motors, in particular when manufactured in various series of types.

  13. China's modern day Great Wall : the 40 inch West to East Gas Pipeline Project

    International Nuclear Information System (INIS)

    Gray, L.A.B.

    2004-01-01

    In order to fuel China's economic growth, PetroChina began construction of the West to East Natural Gas Pipeline Project (WEPP) in 2001 to transport large quantities of natural gas reserves from the Tarim Basin in the Xinjiang Autonomous Region in far western China to markets in eastern China. The WEPP is the first large diameter, cross-country pipeline project ever constructed in China, and was the first to use automatic welding and automatic ultrasonic inspection on pipelines in China. This paper addressed the management, engineering, procurement and construction challenges of the WEPP. Upon completion of the 3,800 km, 1.016 mm mainline pipeline, construction will begin on other major facilities, such 294 km of lateral line, dual fiber optic conduits with the mainline, 1,100 km of access roads, 23 metering stations, 18 pigging stations, 10 compressor stations, 16 mountain tunnels, 16 aerial crossings, 1 crossing of the Yangtze River, 3 crossings of the Yellow River, a gas control center, and SCADA system. Houston-based Universal Ensco Inc. was awarded a contract to perform a feasibility study as well as a construction supervision contract by PetroChina for the WEPP. Universal also designed a gas turbine drive compressor station at Lunnan and an electric drive compressor station at Zhengzhou. This paper demonstrated that business in China for foreign companies in the pipeline industry is evolving and several changes can be expected as the state planned economy is reformed to a free market economy. 4 refs., 5 tabs., 17 figs.

  14. Low-Cost, Manufacturable, 6-Inch Wafer Bonding Process for Next-Generation 5-Junction IMM+Ge Photovoltaic Devices Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a 6-inch wafer bonding process to allow bonding of a multi-junction inverted metamorphic (IMM) tandem solar cell structure to an...

  15. MRIR/Nimbus-2 Images of Daytime Brightness Temperature on 4 x 5 inch Film Sheets V001 (MRIRN2IM) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — MRIRN2IM is the Nimbus-2 Medium Resolution Infrared Radiometer (MRIR) data product consisting of 4 x 5 inch photographic film sheets. Each film sheet contains an...

  16. MRIR/Nimbus-3 Images of Daytime Brightness Temperature on 4 x 5 inch Film Sheets V001 (MRIRN3IM) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — MRIRN3IM is the Nimbus-3 Medium Resolution Infrared Radiometer (MRIR) data product consisting of 4 x 5 inch photographic film sheets. Each film sheet contains an...

  17. Diameter-tailored telecom-band luminescence in InP/InAs heterostructure nanowires grown on InP (111)B substrate with continuously-modulated diameter from microscale to nanoscale.

    Science.gov (United States)

    Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki

    2018-04-02

    We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.

  18. Diameter-tailored telecom-band luminescence in InP/InAs heterostructure nanowires grown on InP (111)B substrate with continuously-modulated diameter from microscale to nanoscale

    Science.gov (United States)

    Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki

    2018-04-01

    We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.

  19. Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

  20. Atom-bond connectivity index and diameter of graphs

    Directory of Open Access Journals (Sweden)

    Lin WU

    2016-12-01

    Full Text Available For further study of the numerous nice properties of topological indices in physical and chemical fields, it is worth considering the relation between a degree-based index and a distance-based index. With the fact that diameter is an invariant based on distance, the relations between atom-bond connectivity index, diameter in trees and unicyclic graphs are studied. Based on relative lemma, the relation between atom-bond connectivity index and diameter in tree and unicyclic graphs is investigated, then the sharp lower bounds of the difference of index and diameter are given.

  1. Combined influence of implant diameter and alveolar ridge width on crestal bone stress: a quantitative approach.

    Science.gov (United States)

    Yu, Wonjae; Jang, Yoon-Je; Kyung, Hee-Moon

    2009-01-01

    To quantitatively evaluate the combined influence of implant diameter and alveolar ridge width on crestal bone stress. ITI solid-screw implants, 10 mm in length and 3.3, 4.1, and 4.8 mm in diameter, and the alveolar bone were modeled using axisymmetric finite elements. Four different alveolar ridge geometries were selected for each implant: 5-, 6-, 7-, and 8-mm-wide ridges for the 3.3-mm implants; 6-, 7-, 8-, and 9-mm-wide ridges for the 4.1-mm implants; and 7-, 8-, 9-, and 10-mm-wide ridges for the 4.8-mm implants. A nonaxial oblique load of 100 N was applied at 30 degrees to the implant axis. Regression analysis was used to avoid ambiguity when estimating the peak stress occurring at the coronal contact point between the implant and the crestal bone, ie, the singularity point. Peak stresses were dependent on both implant diameter and alveolar ridge width. Substantially lower stresses were recorded around the implants placed in narrower ridges. A regression analysis may be used to quantify the peak stress at the singularity point. An implant with a diameter that is at least half the ridge width is recommended to reduce the stress concentration in the crestal bone.

  2. Investigation of the relations between screw diameter and pilot hole diameter with withdrawal resistance in LVL for establishing regression model

    Directory of Open Access Journals (Sweden)

    mossayeb dalvand

    2018-02-01

    Full Text Available In this study, variation in screw diameter and corresponding pilot hole, and relationship between these variables with withdrawal resistance for establishing multiple linear regression model was investigated. In this investigation 9-ply LVL was made of poplar (Populus deltoids. LVL was produced with polyvinyl acetate adhesive. Test specimens were prepared from LVL produced with dimensions of 7.5 * 7.5 cm. Dimension of pilot hole embedded in specimens at 4 levels (50, 60, 70 and 80 present of nominal screw diameter. The test Specimens were studied with nominal screw diameter 4.2, 5, 6 and 7mm were produced. Withdrawal resistance of screw was tested from surface and, edge and cross-sections. Results have shown that withdrawal resistance from edge (perpendicular to grain was more than withdrawal resistance from face and cross-section (parallel to grain. Also the results have shown that withdrawal resistance of different screw diameter decreased with increase of pilot hole diameter, but withdrawal resistance increased with increase of screw diameter itself. The highest withdrawal resistance was obtained from screw 7 mm in diameters and predrilled hole diameter 50% of screw diameter. The lowest withdrawal resistance was observed from screw 4.2 mm in diameter and predrilled hole diameter 80% of screw diameter. Finally multiple linear regression models ys= 3.055+.411X1-3.358X2, ye║=2.6361.694X1+.089X2 and ye┴= 2.334+.509X1-2.901X2 were obtained to predict of withdrawal resistance for face, cross-section and edge respectively.

  3. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    Energy Technology Data Exchange (ETDEWEB)

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  4. Effect of Crucible Diameter Reduction on the Convection, Macrosegregation, and Dendritic Morphology during Directional Solidification of Pb-2.2 Wt Pct Sb Alloy

    Science.gov (United States)

    Chen, Jun; Tewari, S. N.; Magadi, G.; DeGroh, H. C., III

    2003-01-01

    The Pb-2.2 wt pct Sb alloy has been directionally solidified in 1-, 2-, 3-, and 7-mm-diameter crucibles with planar and dendritic liquid-solid interface orphology. For plane front solidification, the experimentally observed macrosegregation along the solidified length follows the relationship proposed by Favier. Application of a 0.4 T transverse magnetic field has no effect on the extent of convection. Reducing the ampoule diameter appears to decrease the extent of convection. However, extensive convection is still present even in the 1-mm-diameter crucible. An extrapolation of the observed behavior indicated that nearly diffusive transport conditions require ampoules that are about 40 microns in diameter. Reduction of the crucible diameter does not appear to have any significant effect on the primary dendrite spacing. However, it results in considerable distortion of the dendrite morphology and ordering. This is especially true for the 1-mm diameter samples.

  5. Elaboration of building materials from industrial waste from solid granular diatomaceous earth; Elaboracion de material de construccion a partir de residuos industriales solidos granulares procedentes de tierras diatomaceas

    Energy Technology Data Exchange (ETDEWEB)

    Del Angel S, A.

    2015-07-01

    In this work the initial characterization of granular solid industrial waste from diatomaceous earth was carried out using techniques of Scanning Electron Microscopy and X-ray Diffraction. In a second stage leaching of the material was undertaken to the US Patent Number 5, 376,000 and 5, 356,601 obtaining the samples M1-S ph 2, M1-L ph, M1-S ph 10 and M1-L ph 10. In the third stage a new characterization of the samples obtained with the techniques of Scanning Electron Microscopy, X-ray Diffraction and Atomic Absorption Spectrometry was performed, the latter in order to determine the efficiency percentage of the leaching process. In the fourth stage the specimens for performing mechanical, physical and chemical tests were manufactured, using molds as PVC pipes of 1 inch in diameter and 2 inches in length, with a composition of 50% of diatomaceous earth and 50% of cement produced in each. Finally, in the fifth stage mechanical testing (compression resistance), physical (moisture absorption rate) and chemical (composition and structure of the material) are performed. In the last stage, when conducting mechanical testing with the test specimens, the presence of bubbles enclosed in each obtaining erroneous results noted, so it was necessary to develop the specimens again, obtaining in this occasion concentrations of 20:80, 40:60, 60:40 and 80:20 of diatomaceous earth with the cement. These results were analyzed to determine if the used material is suitable for the production of building materials such as bricks or partitions, being demonstrated by the tests carried out if they are eligible. (Author)

  6. Sex Dimorphism of the Heart Diameters and Cardiothoracic Ratios ...

    African Journals Online (AJOL)

    Objective: To determine gender associated differences in the cardiothoracic ratio (CTR) and heart diameters in a normal Nigerian population. Subject and Method: The normal heart diameters and cardiothoracic ratios were measured from posteroanterior (PA) chest radiographs of healthy 510 male and 508 female ...

  7. Generalized height-diameter models for Populus tremula L. stands

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... Using permanent sample plot data, selected tree height and diameter functions were evaluated for their predictive abilities for Populus tremula stands in Turkey. Two sets of models were evaluated. The first set included five models for estimating height as a function of individual tree diameter; the second set.

  8. Mean particle diameters : From statistical definition to physical understanding

    NARCIS (Netherlands)

    Alderliesten, M.

    2008-01-01

    Mean particle diameters are important for the science of particulate systems. This thesis deals with a definition system for these mean diameters, called Moment-Ratio (M-R) definition system, and provides a general statistical and physical basis. Also, the current DIN/ISO definition system is

  9. Growth process and diameter structure of Pinus tabulaeformis forest ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... Using stem analysis method, the biomass, growing process and diameter structure of 21-year shady and sunny slope Pinus tabulaeformis forest were investigated in hilly loess-gully region. Results showed that there were distinct difference in the indexes, tree height, diameter at breast height (DBH).

  10. Mean Normal Portal Vein Diameter Using Sonography among ...

    African Journals Online (AJOL)

    BACKGROUND: Mean portal vein diameter is considered as the best indicator for portal hypertension. However, the cutoff point differs from study to study (above 10-15 mm) despite the existence of normal mean portal vein diameter between 10-15 mm in different settings.This implies the existence of limited evidence on ...

  11. Growth process and diameter structure of Pinus tabulaeformis forest ...

    African Journals Online (AJOL)

    Using stem analysis method, the biomass, growing process and diameter structure of 21-year shady and sunny slope Pinus tabulaeformis forest were investigated in hilly loess-gully region. Results showed that there were distinct difference in the indexes, tree height, diameter at breast height (DBH) and timber volume ...

  12. Relationships between stem diameter at breast height (DBH), tree ...

    African Journals Online (AJOL)

    Trees show considerable variation and flexibility in their size of crowns, height and stem diameter at breast height (dbh). Dbh has been used as predictor variables in diameter and height growth equations. Relationships between dbh, tree height, crown length, crown height and crown ratio of Vitellaria paradoxa were ...

  13. Generalized height-diameter models for Populus tremula L. stands ...

    African Journals Online (AJOL)

    On average, by including stand level attributes, root mean square values were reduced by 21 cm. In the second set, the best results were obtained by the Schnute's function. In this function, dominant diameter and dominant height independent variables in addition to tree diameter were found significant at 0.01 significant ...

  14. Relationships between diameter and height of trees in natural ...

    African Journals Online (AJOL)

    Relationships between diameter and height of trees in natural tropical forest in Tanzania. Wilson A Mugasha, Ole M Bollandsås, Tron Eid. Abstract. The relationship between tree height (h) and tree diameter at breast height (dbh) is an important element describing forest stands. In addition, h often is a required variable in ...

  15. Influence of high intensity ultrasound with different probe diameter ...

    African Journals Online (AJOL)

    The main goal of this research is to analyze the influence of ultrasonic probe diameters (7 and 10 mm) of high-intensity ultrasound with constant frequency (30 kHz) on the degree of homogenization (variance) of cow milk. Influence of different probe diameters on the physical properties of cow milk was also tested. Changes ...

  16. Solid surface tension measured by a liquid drop under a solid film.

    Science.gov (United States)

    Nadermann, Nichole; Hui, Chung-Yuen; Jagota, Anand

    2013-06-25

    We show that a drop of liquid a few hundred microns in diameter placed under a solid, elastic, thin film (∼10 μm thick) causes it to bulge by tens of microns. The deformed shape is governed by equilibrium of tensions exerted by the various interfaces and the solid film, a form of Neumann's triangle. Unlike Young's equation, which specifies the contact angles at the junction of two fluids and a (rigid) solid, and is fundamentally underdetermined, both tensions in the solid film can be determined here if the liquid-vapor surface tension is known independently. Tensions in the solid film have a contribution from elastic stretch and a constant residual component. The residual component, extracted by extrapolation to films of vanishing thickness and supported by analysis of the elastic deformation, is interpreted as the solid-fluid surface tension, demonstrating that compliant thin-film structures can be used to measure solid surface tensions.

  17. Diameter of common bile duct: what are the predicting factors?

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2007-07-01

    Full Text Available

    BACKGROUND: This was a study to determine the correlation between the common bile duct (CBD diameter and demographic data, fasting, and the history of opium addiction.
    METHODS: This was a cross-sectional study on 375 patients (>16 years old including 219 females and 156 males. They had no evident hepatobiliary or pancreatic disease and underwent abdominopelvic ultrasonography for measurement of their CBD diameter. Ultrasound (US was performed to measure CBD diameter at the porta hepatis (proximal part and behind the head of the pancreas (distal part. Correlation coefficients for the association between CBD diameter and predictive factors were calculated. t-test was applied to compare the means between the groups.
    RESULTS: The mean CBD diameter (1 standard deviation, in proximal and distal parts were 3.64 mm (±1.2 and 3.72 mm (±1.2, respectively. The CBD diameters (proximal and distal were significantly (P<0.05 correlated with age (r = 0.55 and 0.54, respectively, BMI (r = 0.25 and 0.27, respectively and portal vein diameter (r = 0.24 and 0.22, respectively. Distal diameter of CBD was significantly larger in opium addicts (5.66 ± 2.65 in comparison with non addicts (3.68 ± 1.17, P = 0.04.
    CONCLUSIONS: CBD diameter associates with age, BMI, portal vein diameter and opium addiction. CBD dilatation, if it can not be explained by age, opium usage or large BMI, should be evaluated further to rule out obstruction.
    KEY WORDS: Common bile duct, predicting factors, ultrasonography.

  18. Relation of Coronary Artery Diameters With Cardiorespiratory Fitness.

    Science.gov (United States)

    Ho, John S; Cannaday, John J; FitzGerald, Shannon J; Leonard, David; Finley, Carrie E; Wade, Wendy A; Reinhardt, Dale B; Ellis, Joe R; Barlow, Carolyn E; Haskell, William L; Defina, Laura F; Gibbons, Larry W; Cooper, Kenneth H

    2018-02-06

    Cardiorespiratory fitness is associated with reduced cardiovascular morbidity and mortality when adjusted for traditional risk factors. Mechanisms by which fitness reduces risk have been studied but remain incompletely understood. We hypothesize that higher fitness is associated with larger coronary artery diameters independent of its effect on traditional risk factors. Two independent measurements of the proximal diameters of the left main, left anterior descending, left circumflex, and right coronary arteries were obtained from gated multidetector computed tomography scans in 500 men from the Cooper Center Longitudinal Study (CCLS). Men with coronary artery calcium scores ≥10 were excluded. Fitness was measured with a maximal exercise treadmill test and reported by quintiles and as a function of METs. We then evaluated the relation between coronary artery diameters and fitness using mixed effect regression models. Higher fitness was associated with larger coronary artery diameters after adjustment for body surface area, smoking status, low-density lipoprotein and high-density lipoprotein cholesterol, resting systolic blood pressure, and serum glucose. When examined continuously, each MET increase in fitness was associated with a mean 0.03 ± 0.01 mm larger diameter of the left main, a 0.04 ± 0.01 mm larger diameter of the left anterior descending, a 0.05 ± 0.01 mm larger diameter of the left circumflex, and a 0.07 ± 0.01 mm larger diameter of the right coronary artery (p = 0.002). This correlation between fitness and coronary artery diameters was most prominent for fitness levels above 10 METs. In conclusion, higher fitness is associated with larger coronary artery diameters. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Influence of spacing on the survival, frequency of diameter classes and height/diameter ratio in Eucalyptus urophylla. [In Portuguese

    Energy Technology Data Exchange (ETDEWEB)

    Brandi, R.M.; Couto, L.; Neto, F. de P.

    1977-01-01

    Survival of hybrid (unspecified parentage) E. urophylla in Minas Gerais after 93 months ranged from 47.1% at a spacing of 2 x 2 m to 60.5% at 3 x 4 m. Close spacing gave the largest number of trees per unit area, but with smaller average diameter Height/diameter ratio was not influenced by spacing.

  20. Pulmonary adenocarcinomas appearing as part-solid ground-glass nodules: Is measuring solid component size a better prognostic indicator?

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Eui Jin; Ryu, Youngjin; Lee, Sang Min [Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, 101, Daehangno, Jongno-gu, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, 101, Daehangno, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Kim, Young Tae [Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Thoracic and Cardiovascular Surgery, Seoul (Korea, Republic of); Kim, Young Whan [Seoul National University College of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine and Lung Institute, Seoul (Korea, Republic of)

    2014-10-02

    To assess whether measuring the solid portion of adenocarcinomas appearing as part-solid ground-glass nodules (GGNs) can predict a patient's prognosis accurately and how the prognosis corresponds to that of solid nodules. 501 patients (solid nodule group, 304; part-solid GGN group, 197) underwent curative surgery for stage I adenocarcinomas. Maximal diameters of the whole lesion including ground-glass opacities (D{sub whole}) and solid components only (D{sub solid}) were measured on CT. Disease-free survival (DFS) and overall survival (OS) were calculated from the date of surgery. D{sub solid} was a significant prognostic factor in the part-solid GGN group, while D{sub whole} was not. Part-solid GGNs with D{sub solid} ≤2 cm showed significantly better DFS (P = 0.016) and OS (P = 0.004) than solid nodules; however, those with D{sub solid} >2 cm did not show a significant difference. Hazard ratio (HR) for increase in D{sub solid} was significantly greater in part-solid GGNs than in solid nodules (P = 0.009). For OS, HR for increase in D{sub solid} was greater in part-solid GGNs than in solid nodule, which was marginally not significant (P = 0.060). D{sub solid} was better than D{sub whole} for prognosis prediction of adenocarcinomas appearing as part-solid GGNs. In addition, the influence of D{sub solid} on prognosis in the part-solid GGN group was greater than in the solid nodule group. (orig.)

  1. An ecophysiological and developmental perspective on variation in vessel diameter.

    Science.gov (United States)

    Hacke, Uwe G; Spicer, Rachel; Schreiber, Stefan G; Plavcová, Lenka

    2017-06-01

    Variation in xylem vessel diameter is one of the most important parameters when evaluating plant water relations. This review provides a synthesis of the ecophysiological implications of variation in lumen diameter together with a summary of our current understanding of vessel development and its endogenous regulation. We analyzed inter-specific variation of the mean hydraulic vessel diameter (D v ) across biomes, intra-specific variation of D v under natural and controlled conditions, and intra-plant variation. We found that the D v measured in young branches tends to stay below 30 µm in regions experiencing winter frost, whereas it is highly variable in the tropical rainforest. Within a plant, the widest vessels are often found in the trunk and in large roots; smaller diameters have been reported for leaves and small lateral roots. D v varies in response to environmental factors and is not only a function of plant size. Despite the wealth of data on vessel diameter variation, the regulation of diameter is poorly understood. Polar auxin transport through the vascular cambium is a key regulator linking foliar and xylem development. Limited evidence suggests that auxin transport is also a determinant of vessel diameter. The role of auxin in cell expansion and in establishing longitudinal continuity during secondary growth deserve further study. © 2016 John Wiley & Sons Ltd.

  2. Diameter dependent electron transfer kinetics in semiconductor-enzyme complexes.

    Science.gov (United States)

    Brown, Katherine A; Song, Qing; Mulder, David W; King, Paul W

    2014-10-28

    Excited state electron transfer (ET) is a fundamental step for the catalytic conversion of solar energy into chemical energy. To understand the properties controlling ET between photoexcited nanoparticles and catalysts, the ET kinetics were measured for solution-phase complexes of CdTe quantum dots and Clostridium acetobutylicum [FeFe]-hydrogenase I (CaI) using time-resolved photoluminescence spectroscopy. Over a 2.0-3.5 nm diameter range of CdTe nanoparticles, the observed ET rate (kET) was sensitive to CaI concentration. To account for diameter effects on CaI binding, a Langmuir isotherm and two geometric binding models were created to estimate maximal CaI affinities and coverages at saturating concentrations. Normalizing the ET kinetics to CaI surface coverage for each CdTe diameter led to k(ET) values that were insensitive to diameter, despite a decrease in the free energy for photoexcited ET (ΔGET) with increasing diameter. The turnover frequency (TOF) of CaI in CdTe-CaI complexes was measured at several molar ratios. Normalization for diameter-dependent changes in CaI coverage showed an increase in TOF with diameter. These results suggest that k(ET) and H2 production for CdTe-CaI complexes are not strictly controlled by ΔG(ET) and that other factors must be considered.

  3. The Relationship amongst Intervertebral Disc Vertical Diameter, Lateral Foramen Diameter and Nerve Root Impingement in Lumbar Vertebra

    Directory of Open Access Journals (Sweden)

    Yusof MI

    2018-03-01

    Full Text Available Introduction: The vertical diameter of the foramen is dependent upon the vertical diameter of the corresponding intervertebral disc. A decrease in disc vertical diameter has direct anatomic consequences to the foraminal diameter and area available for the nerve root passing through it. This study is to establish the relationship amongst the intervertebral disc vertical diameter, lateral foramen diameters and nerve root compression in the lumbar vertebra. Materials and Methods: Measurements of the study parameters were performed using sagittal MRI images. The parameters studied were: intervertebral disc vertical diameter (DVD, foraminal vertical diameter (FVD, foraminal transverse diameter (FTD and nerve root diameter (NRD of both sides. The relationship between the measured parameters were then analyzed. Results: A total of 62 MRI images were available for this study. Statistical analysis showed moderate to strong correlation between DVD and FVD at all the lumbar levels except at left L23 and L5S1 and right L3L4 and L4L5. Correlation between DVD and FTD were not significant at all lumbar levels. Regression analysis showed that a decrease of 1mm of DVD was associated with 1.3, 1.7, 3.3, 3.3 and 1.3mm reduction of FVD at L1L2, L2L3, L3L4, L4L5 and L5S1 respectively. Conclusion: Reduction of DVD was associated with reduction of FVD. However, FVD was relatively wide for the nerve root even with complete loss of DVD. FTD was much narrower than the FVD making it more likely to cause nerve root compression at the exit foramina. These anatomical details should be given consideration in treating patients with lateral canal stenosis.

  4. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-01-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed in prior quarters while Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in cast-iron test pipe segments. Efforts in the current quarter continued to focus on Tasks 4-8. Highly valuable lessons were learned from field tests of the 4-inch gas pipe repair robot in cast-iron pipe at Public Service Electric & Gas. (These field tests were conducted and reported last quarter.) These tests identified several design issues which need to be implemented in both the small- and large-diameter

  5. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-11-01

    & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe in the previous quarter. Field tests with the 4-inch size fitting were completely successful and did not reveal any significant design issues. The primary suggestion from the PSE&G field crew was to produce a version which completely bolts together and does not require a long seam weld. This could be used in low-pressure cast iron mains to reduce installation time. A bolt-on version is now being designed based on this recommendation. Task 8 (System Integration and Laboratory Validation) continued with the development of the robot module inter-connects and of a master LabView-based system display and control software.

  6. Characterization of the first double-sided 3D radiation sensors fabricated at FBK on 6-inch silicon wafers

    International Nuclear Information System (INIS)

    Sultan, D.M.S.; Mendicino, R.; Betta, G.-F. Dalla; Boscardin, M.; Ronchin, S.; Zorzi, N.

    2015-01-01

    Following 3D pixel sensor production for the ATLAS Insertable B-Layer, Fondazione Bruno Kessler (FBK) fabrication facility has recently been upgraded to process 6-inch wafers. In 2014, a test batch was fabricated to check for possible issues relevant to this upgrade. While maintaining a double-sided fabrication technology, some process modifications have been investigated. We report here on the technology and the design of this batch, and present selected results from the electrical characterization of sensors and test structures. Notably, the breakdown voltage is shown to exceed 200 V before irradiation, much higher than in earlier productions, demonstrating robustness in terms of radiation hardness for forthcoming productions aimed at High Luminosity LHC upgrades

  7. Calibration of the radiometric asteroid scale using occultation diameters

    Science.gov (United States)

    Brown, R. H.; Morrison, D.; Telesco, C. M.; Brunk, W. E.

    1982-10-01

    The paper describes a new approach to the calibration of the radiometric asteroid scale, which relies on recent accurate occultation measurements of the diameters of 2 Pallas (Wasserman et al., 1979) and 3 Juno (Millis et al., 1981), and the Voyager diameter of J4 Callisto, as well as IR photometry of these objects obtained with the NASA 3-m Infrared Telescope Facility. It is shown that this calibration is internally consistent to better than 5%, and probably has an absolute accuracy of + or - 5%. It is noted that a revision of the TRIAD radiometric diameters downward is required to bring them into agreement with the new calibration.

  8. The development of 8 inch roll-to-plate nanoimprint lithography (8-R2P-NIL) system

    Science.gov (United States)

    Lee, Lai Seng; Mohamed, Khairudin; Ooi, Su Guan

    2017-07-01

    Growth in semiconductor and integrated circuit industry was observed in the past decennium of years for industrial technology which followed Moore's law. The line width of nanostructure to be exposed was influenced by the essential technology of photolithography. Thus, it is crucial to have a low cost and high throughput manufacturing process for nanostructures. Nanoimprint Lithography technique invented by Stephen Y. Chou was considered as major nanolithography process to be used in future integrated circuit and integrated optics. The drawbacks of high imprint pressure, high imprint temperature, air bubbles formation, resist sticking to mold and low throughput of thermal nanoimprint lithography on silicon wafer have yet to be solved. Thus, the objectives of this work is to develop a high throughput, low imprint force, room temperature UV assisted 8 inch roll to plate nanoimprint lithography system capable of imprinting nanostructures on 200 mm silicon wafer using roller imprint with flexible mold. A piece of resist spin coated silicon wafer was placed onto vacuum chuck drives forward by a stepper motor. A quartz roller wrapped with a piece of transparent flexible mold was used as imprint roller. The imprinted nanostructures were cured by 10 W, 365 nm UV LED which situated inside the quartz roller. Heat generated by UV LED was dissipated by micro heat pipe. The flexible mold detaches from imprinted nanostructures in a 'line peeling' pattern and imprint pressure was measured by ultra-thin force sensors. This system has imprinting speed capability ranging from 0.19 mm/s to 5.65 mm/s, equivalent to imprinting capability of 3 to 20 pieces of 8 inch wafers per hour. Speed synchronization between imprint roller and vacuum chuck was achieved by controlling pulse rate supplied to stepper motor which drive the vacuum chuck. The speed different ranging from 2 nm/s to 98 nm/s is achievable. Vacuum chuck height was controlled by stepper motor with displacement of 5 nm/step.

  9. Validity of using modified capillary column with larger diameter to study the Cs diffusion in local Taiwan laterite

    International Nuclear Information System (INIS)

    Tsing-Hai Wang; National Tsing Hua University, Hsinchu, Taiwan; Wen-Chun Yeh; Shih-Chin Tsai; Yi-Lin Jan; Shi-Ping Teng

    2008-01-01

    We have examined the working diameter of capillary columns with diameter of 5, 7, 10 and 20 mm. These modified capillary columns were carefully filled with local Taiwan laterite (LTL). The porosity and density of these packed columns was 0.51±0.02 g/g and 1.27±0.05 g/cm 3 , respectively. The diffusion experiments were then carried out in synthetic groundwater with Cs loading of 0.1mM at room temperature. Experimental results have shown that the diffusion profiles of modified capillary columns fit Fick's second law very well. This result revealed that the working diameter of a capillary column can be expanded to at least to 20 mm without affecting the validity of the derived diffusion coefficients. Among these columns, the ones with 5 mm diameter show the most consistent results of the derived K d , apparent and effective diffusion coefficients. Although the derived distribution and effective diffusion coefficients slightly decrease as the diameter of these columns increases due to the increase of the solid/liquid ratio. These values are still informative of the Cs diffusion in local Taiwan laterite. Moreover, our results clearly demonstrate the potential of using 'modified capillary method' to study the diffusion behaviors of concerned radionuclide because columns with large diameter enable the filling with more versatile geological substances. (author)

  10. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...... initial response and a higher ultimate capacity. The initial stiffness of the soil-structure interaction measured in the centrifuge tests, equivalent to initial stiffness of p-y curves, shows a dependency of depth and diameter. Control issues in relation to cyclic tests have resulted in tests...... on the structure and the productivity of the turbine. Current design practice for monopiles are based on p-y curves developed for slender piles with a diameter of 0.6 m. The focus on the structure stiffness has entailed a significant research on the soil-structure interaction for large diameter monopiles...

  11. Porosity Assessment for Different Diameters of Coir Lignocellulosic Fibers

    Science.gov (United States)

    da Luz, Fernanda Santos; Paciornik, Sidnei; Monteiro, Sergio Neves; da Silva, Luiz Carlos; Tommasini, Flávio James; Candido, Verônica Scarpini

    2017-10-01

    The application of natural lignocellulosic fibers (LCFs) in engineering composites has increased interest in their properties and structural characteristics. In particular, the inherent porosity of an LCF markedly affects its density and the adhesion to polymer matrices. For the first time, both open and closed porosities of a natural LCF, for different diameter ranges, were assessed. Fibers extracted from the mesocarp of the coconut fruit were investigated by nondestructive methods of density measurements and x-ray microtomography (microCT). It was found that, for all diameter ranges, the closed porosity is significantly higher than the open porosity. The total porosity increases with diameter to around 60% for coir fibers with more than 503 μm in diameter. The amount and characteristics of these open and closed porosities were revealed by t test and Weibull statistics as well as by microCT.

  12. Synthesis of very small diameter silica nanofibers using sound waves.

    Science.gov (United States)

    Datskos, Panos; Chen, Jihua; Sharma, Jaswinder

    2014-07-14

    Silica nanofibers of an average diameter ≈30 nm and length ≈100 μm have been synthesized using an unprecedented strategy: sound waves. A new phenomenon, spinning off the nanofibers at silica rod tips, is also observed.

  13. Observations on placentome diameters in gestating West African ...

    African Journals Online (AJOL)

    ADEYEYE

    2015-09-09

    /10.4314/sokjvs.v13i3.4. Observations on placentome diameters in gestating West. African dwarf does experimentally infected with Trypanosoma brucei. OO Leigh. Department of Veterinary Surgery and Reproduction, ...

  14. Deriving muscle fiber diameter from recorded single fiber potential.

    Science.gov (United States)

    Zalewska, Ewa

    2017-12-01

    The aim of the study was to estimate muscle fiber diameters through analysis of single muscle fiber potentials (SFPs) recorded in the frontalis muscle of a healthy subject. Our previously developed analytical and graphic method to derive fiber diameter from the analysis of the negative peak duration and the amplitude of SFP, was applied to a sample of ten SFPs recorded in vivo. Muscle fiber diameters derived from the simulation method for the sample of frontalis muscle SFPs are consistent with anatomical data for this muscle. The results confirm the utility of proposed simulation method. Outlying data could be considered as the result of a contribution of other fibers to the potential recorded using an SFEMG electrode. Our graphic tool provides a rapid estimation of muscle fiber diameter. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. NEOWISE DIAMETERS AND ALBEDOS V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This PDS data set represents a compilation of published diameters, optical albedos, near-infrared albedos, and beaming parameters for minor planets detected by...

  16. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure......PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...

  17. Ultrasonic measurement of biparietal diameter and femur in foetal ...

    African Journals Online (AJOL)

    Our objective was to verify ultrasonic measurement of biparietal diameter and femur in foetal age determination in the second and third trimester of pregnancy. The prospective cross sectional ... (3) L'errur standard pour la longueur du femur était de 0.2552 contre 0.3009 pour l'estimation du diameter bi-pariétal. Les résultats ...

  18. Catalytic growth of carbon nanotubes with large inner diameters

    Directory of Open Access Journals (Sweden)

    WEI REN ZHONG

    2005-02-01

    Full Text Available Carbon nanotubes (2.4 g/g catalyst, with large inner diameters were successfully synthesized through pyrolysis of methane on a Ni–Cu–Al catalyst by adding sodium carbonate into the carbon nanotubes growth system. The inner diameter of the carbon nanotubes prepared by this method is about 20–60 nm, while their outer diameter is about 40–80 nm. Transmission electron microscopy and X-ray diffraction were employed to investigate the morphology and microstructures of the carbon nanotubes. The analyses showed that these carbon nanotubes have large inner diameters and good graphitization. The addition of sodium carbonate into the reaction system brings about a slight decrease in the methane conversion and the yield of carbon. The experimental results showed that sodium carbonate is a mildly toxic material which influenced the catalytic activity of the Ni–Cu–Al catalyst and resulted in the formation of carbon nanotubes with large inner diameters. The growth mechanism of the carbon nanotubes with large inner diameters is discussed in this paper.

  19. Reduction of nanowire diameter beyond lithography limits by controlled catalyst dewetting

    Science.gov (United States)

    Calahorra, Yonatan; Kerlich, Alexander; Amram, Dor; Gavrilov, Arkady; Cohen, Shimon; Ritter, Dan

    2016-04-01

    Catalyst assisted vapour-liquid-solid is the most common method to realize bottom-up nanowire growth; establishing a parallel process for obtaining nanoscale catalysts at pre-defined locations is paramount for further advancement towards commercial nanowire applications. Herein, the effect of a selective area mask on the dewetting of metallic nanowire catalysts, deposited within lithography-defined mask pinholes, is reported. It was found that thin disc-like catalysts, with diameters of 120-450 nm, were transformed through dewetting into hemisphere-like catalysts, having diameters 2-3 fold smaller; the process was optimized to about 95% yield in preventing catalyst splitting, as would otherwise be expected due to their thickness-to-diameter ratio, which was as low as 1/60. The catalysts subsequently facilitated InP and InAs nanowire growth. We suggest that the mask edges prevent surface migration mediated spreading of the dewetted metal, and therefore induce its agglomeration into a single particle. This result presents a general strategy to diminish lithography-set dimensions for NW growth, and may answer a fundamental challenge faced by bottom-up nanowire technology.

  20. Diameter optimization of VLS-synthesized ZnO nanowires, using statistical design of experiment

    International Nuclear Information System (INIS)

    Shafiei, Sepideh; Nourbakhsh, Amirhasan; Ganjipour, Bahram; Zahedifar, Mostafa; Vakili-Nezhaad, Gholamreza

    2007-01-01

    The possibility of diameter optimization of ZnO nanowires by using statistical design of experiment (DoE) is investigated. In this study, nanowires were synthesized using a vapor-liquid-solid (VLS) growth method in a horizontal reactor. The effects of six synthesis parameters (synthesis time, synthesis temperature, thickness of gold layer, distance between ZnO holder and substrate, mass of ZnO and Ar flow rate) on the average diameter of a ZnO nanowire were examined using the fractional factorial design (FFD) coupled with response surface methodology (RSM). Using a 2 III 6-3 FFD, the main effects of the thickness of the gold layer, synthesis temperature and synthesis time were concluded to be the key factors influencing the diameter. Then Box-Behnken design (BBD) was exploited to create a response surface from the main factors. The total number of required runs for the DoE process is 25, 8 runs for FFD parameter screening and 17 runs for the response surface obtained by BBD. Three extra runs are done to confirm the predicted results

  1. Development and testing of 11- and 24-inch hybrid motors under the joint government/industry IR&D program

    Science.gov (United States)

    Boardman, T. A.; Carpenter, R. L.; Goldberg, B. E.; Shaeffer, C. W.

    1993-01-01

    Establishment of a test facility and associated 11-in.-diameter motor for hybrid propulsion technology development at NASA's George C. Marshall Space Flight Center is discussed in this paper. Results of twenty 11-in.-diameter motor tests with a UTF-29901 (60 percent polycyclopentadiene, 40 percent hydroxyl-terminated polybutadiene)/gaseous oxygen propellant system are presented. Tests at this scale have developed fuel regression correlations for comparison with results of yet-to-be-completed, 24-in.-diameter motor tests; demonstrated combustion efficiency levels in the 95 percent range for both single- and multiple-port grain configurations; have shown smooth and stable throttling characteristics over flight-type throttle ranges; and have begun to establish criteria for stable combustion in hybrid motors. The testing of 24-in. motors has not as yet been initiated and is not addressed.

  2. Girth weld failure in a large diameter gas transmission pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, Chris; Scrivner, Ron [Stress Engineering Services, Inc., Houston, Texas (United States)], email: ron.scrivner@stress.com, email: chris.alexander@stress.com; Exley, Butch [Williams Gas Pipeline, Houston, Texas (United States)], email: butch.d.exley@williams.com

    2010-07-01

    In early 2008, a 30-inch, Grade X52 line pipe ruptured, and an initial failure analysis was conducted on examination of the failed girth weld. Preexisting welding imperfections, dating from the 1940s, were determined to be the metallurgical cause, but another factor was external loading dating from the 1980s. The authors conducted a comprehensive investigation that also included a fracture mechanics analysis and a finite element analysis to find out about localized stresses in the girth weld. The overriding conclusion is that the failure cannot be imputed to any single factor. Weld imperfections generated higher stresses because, after excavation work and refill with non-compact material, ground settlement applied excessive loads on the pipe. If the pipe had not displaced vertically, the failure would probably not have occurred. Excavation practices would probably have been adequate in normal soil conditions, but lack of compaction, followed with excessive moisture just before the failure, generated excessive bending stresses that caused the leak.

  3. Failure Diameter of PBX 9502: Simulations with the SURFplus model

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-03

    SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regime are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.

  4. Diameter measurements of polystyrene particles with atomic force microscopy

    Science.gov (United States)

    Garnaes, J.

    2011-09-01

    The size of (nano) particles is a key parameter used in controlling their function. The particle size is also important in order to understand their physical and chemical properties and regulate their number in health and safety issues. In this work, the geometric diameters of polystyrene spheres of nominal diameter 100 nm are measured using atomic force microscopy. The measurements are based on the apex height and on the average distance between neighbouring spheres when they form a close-packed monolayer on a flat mica substrate. The most important influence parameters for the determination of the geometric diameter are the lateral air gaps and deformation of the spheres. The lateral air gaps are caused by significant size variations of the individual spheres, and a correction is calculated based on the simulation of packing of spheres. The deformation of the spheres is caused mainly by capillary forces acting when they are in contact with each other or with the mica substrate. Based on calculated capillary forces and the literature values of the elastic properties of the polystyrene and mica, the deformation is estimated to be 2 nm with a standard uncertainty of 2 nm. The geometric diameter of the polystyrene spheres was measured with a combined standard uncertainty of ≈3 nm. The measured vertical diameter of 92.3 nm and the certified mobility equivalent diameter measured by differential mobility analysis (DMA) are marginally consistent at a confidence level of 95%. However, the measured lateral geometric diameter was 98.9 nm and is in good agreement with DMA.

  5. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-04-01

    optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being placed into manufacture. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

  6. WET SOLIDS FLOW ENHANCEMENT; SEMIANNUAL

    International Nuclear Information System (INIS)

    Hugo S. Caram; Natalie Foster

    1997-01-01

    The objective was to visualize the flow of granular materials in flat bottomed silo. This was done by for dry materials introducing mustard seeds and poppy seeds as tracer particles and imaging them using Nuclear Magnetic Resonance. The region sampled was a cylinder 25 mm in diameter and 40 mm in length. Eight slices containing 128*128 to 256*256 pixels were generated for each image. The size of the silo was limited by the size of the high resolution NMR imager available. Cross-sections of 150mm flat bottomed silos, with the tracer layers immobilized by a gel, showed similar qualitative patterns for both dry and wet granular solids

  7. Memory, emotion, and pupil diameter: Repetition of natural scenes.

    Science.gov (United States)

    Bradley, Margaret M; Lang, Peter J

    2015-09-01

    Recent studies have suggested that pupil diameter, like the "old-new" ERP, may be a measure of memory. Because the amplitude of the old-new ERP is enhanced for items encoded in the context of repetitions that are distributed (spaced), compared to massed (contiguous), we investigated whether pupil diameter is similarly sensitive to repetition. Emotional and neutral pictures of natural scenes were viewed once or repeated with massed (contiguous) or distributed (spaced) repetition during incidental free viewing and then tested on an explicit recognition test. Although an old-new difference in pupil diameter was found during successful recognition, pupil diameter was not enhanced for distributed, compared to massed, repetitions during either recognition or initial free viewing. Moreover, whereas a significant old-new difference was found for erotic scenes that had been seen only once during encoding, this difference was absent when erotic scenes were repeated. Taken together, the data suggest that pupil diameter is not a straightforward index of prior occurrence for natural scenes. © 2015 Society for Psychophysiological Research.

  8. Parametric Probability Distribution Functions for Axon Diameters of Corpus Callosum

    Directory of Open Access Journals (Sweden)

    Farshid eSepehrband

    2016-05-01

    Full Text Available Axon diameter is an important neuroanatomical characteristic of the nervous system that alters in the course of neurological disorders such as multiple sclerosis. Axon diameters vary, even within a fiber bundle, and are not normally distributed. An accurate distribution function is therefore beneficial, either to describe axon diameters that are obtained from a direct measurement technique (e.g., microscopy, or to infer them indirectly (e.g., using diffusion-weighted MRI. The gamma distribution is a common choice for this purpose (particularly for the inferential approach because it resembles the distribution profile of measured axon diameters which has been consistently shown to be non-negative and right-skewed. In this study we compared a wide range of parametric probability distribution functions against empirical data obtained from electron microscopy images. We observed that the gamma distribution fails to accurately describe the main characteristics of the axon diameter distribution, such as location and scale of the mode and the profile of distribution tails. We also found that the generalized extreme value distribution consistently fitted the measured distribution better than other distribution functions. This suggests that there may be distinct subpopulations of axons in the corpus callosum, each with their own distribution profiles. In addition, we observed that several other distributions outperformed the gamma distribution, yet had the same number of unknown parameters; these were the inverse Gaussian, log normal, log logistic and Birnbaum-Saunders distributions.

  9. First mile, first inch

    CSIR Research Space (South Africa)

    Morris, C

    2007-05-01

    Full Text Available Access to Information and Communication Technologies (ICTs) remains one of the biggest challenges to Africa in leapfrogging the development chasm. The African digital divide can be in part attributed to a restrictive regulatory policy...

  10. Characteristics of two-phase flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65401 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2016-12-15

    Two-phase flows in large diameter channels have a great deal of importance in a wide variety of industrial applications. Nuclear systems, petroleum refineries, and chemical processes make extensive use of larger systems. Flows in such channels have very different properties from flows in smaller channels which are typically used in experimental research. In this paper, the various differences between flows in large and small channels are highlighted using the results of previous experimental and analytical research. This review is followed by a review of recent experiments in and model development for flows in large diameter channels performed by the authors. The topics of these research efforts range from void fraction and interfacial area concentration measurement to flow regime identification and modeling, drift-flux modeling for high void fraction conditions, and evaluation of interfacial area transport models for large diameter channels.

  11. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single......This paper proposes a technique for a previously unaddressed problem, namely, mapping axon diameter in crossing fiber regions, using diffusion MRI. Direct measurement of tissue microstructure of this kind using diffusion MRI offers a new class of biomarkers that give more specific information about...... orientation assumption is a reasonable one. However, fiber crossings and other complex configurations are widespread in the brain. In such areas, the existing techniques will fail to provide useful axon diameter indices for any of the individual fiber populations. We propose a novel crossing fiber tissue...

  12. NEOWISE REACTIVATION MISSION YEAR TWO: ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Bauer, J.; Kramer, E. A.; Masiero, J.; Sonnett, S. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2016-09-01

    The Near-Earth Object Wide-Field Infrared Survey Explorer (NEOWISE) mission continues to detect, track, and characterize minor planets. We present diameters and albedos calculated from observations taken during the second year since the spacecraft was reactivated in late 2013. These include 207 near-Earth asteroids (NEAs) and 8885 other asteroids. Of the NEAs, 84% NEAs did not have previously measured diameters and albedos by the NEOWISE mission. Comparison of sizes and albedos calculated from NEOWISE measurements with those measured by occultations, spacecraft, and radar-derived shapes shows accuracy consistent with previous NEOWISE publications. Diameters and albedos fall within ±∼20% and ±∼40%, 1-sigma, respectively, of those measured by these alternate techniques. NEOWISE continues to preferentially discover near-Earth objects which are large (>100 m), and have low albedos.

  13. Diameter sensitive effect in singlewalled carbon nanotubes upon acid treatment

    International Nuclear Information System (INIS)

    Costa, S.; Borowiak-Palen, E.

    2009-01-01

    Singlewalled carbon nanotubes (SWCNT) exhibit very unique properties. As an electronic system they undergo amphoteric doping effects (n-type and p-type) which can be reversed. These processes affect the optical and vibronic properties of the carbon nanotubes. The most common and widely used procedure which changes the properties of the SWCNT is acid treatment applied as a purification procedure. This effect has been widely studied but not fully understood so far. Here, we present a study, in which a diameter sensitive effect has been observed. Therefore, two kinds of SWCNT samples have been studied: (i) produced via chemical vapour deposition with a broad diameter distribution, and (ii) synthesised by the laser ablation technique which is commonly known to result in narrow diameter distribution bulk SWCNT samples. Resonance Raman spectroscopy, optical absorption spectroscopy, and Fourier transform middle-infrared spectroscopy have been applied for the characterisation of the samples.

  14. Bubble behaviour and mean diameter in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Zeitoun, O.; Shoukri, M. [McMaster Univ., Hamilton, Ontario (Canada)

    1995-09-01

    Bubble behaviour and mean bubble diameter in subcooled upward flow boiling in a vertical annular channel were investigated under low pressure and mass flux conditions. A high speed video system was used to visualize the subcooled flow boiling phenomenon. The high speed photographic results indicated that, contrary to the common understanding, bubbles tend to detach from the heating surface upstream of the net vapour generation point. Digital image processing technique was used to measure the mean bubble diameter along the subcooled flow boiling region. Data on the axial area-averaged void fraction distributions were also obtained using a single beam gamma densitometer. Effects of the liquid subcooling, applied heat flux and mass flux on the mean bubble size were investigated. A correlation for the mean bubble diameter as a function of the local subcooling, heat flux and mass flux was obtained.

  15. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su [Korea Atomic Energy Research Institute, Yusung, Taejon (Korea, Republic of)] [and others

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties.

  16. Assessment of RELAP/MOD3 using BETHSY 6.2TC 6-inch cold leg side break comparative test

    International Nuclear Information System (INIS)

    Chung, Young-Jong; Jeong, Jae-Jun; Chang, Won-Pyo; Kim, Dong-Su

    1996-10-01

    This report presents the results of the RELAP5/MOD3 Version 7j assessment on BETHSY 6.2TC. BETHSY 6.2TC test corresponding to a six inch cold leg break LOCA of the Pressurizer Water Reactor(PWR). The primary objective of the test was to provide reference data of two facilities of different scales (BETHSY and LSTF facility). On the other hand, the present calculation aims at analysis of RELAP5/N4OD3 capability on the small break LOCA simulation, The results of calculation have shown that the RELAP5/MOD3 reasonably predicts occurrences as well as trends of the major phenomena such as primary pressure, timing of loop seal clearing, liquid hold up, etc. However, some disagreements also have been found in the predictions of loop seal clearing, collapsed core water level after loop seal clearing, and accumulator injection behaviors. For better understanding of discrepancies in same predictions, several sensitivity calculations have been performed as well. These include the changes of two-phase discharge coefficient at the break junction and some corrections of the interphase drag term. As result, change of a single parameter has not improved the overall predictions and it has been found that the interphase drag model has still large uncertainties

  17. Development of a 55 μm pitch 8 inch CMOS image sensor for the high resolution NDT application

    Science.gov (United States)

    Kim, M. S.; Kim, G.; Cho, G.; Kim, D.

    2016-11-01

    A CMOS image sensor (CIS) with a large area for the high resolution X-ray imaging was designed. The sensor has an active area of 125 × 125 mm2 comprised with 2304 × 2304 pixels and a pixel size of 55 × 55 μm2. First batch samples were fabricated by using an 8 inch silicon CMOS image sensor process with a stitching method. In order to evaluate the performance of the first batch samples, the electro-optical test and the X-ray test after coupling with an image intensifier screen were performed. The primary results showed that the performance of the manufactured sensors was limited by a large stray capacitance from the long path length between the analog multiplexer on the chip and the bank ADC on the data acquisition board. The measured speed and dynamic range were limited up to 12 frame per sec and 55 dB respectively, but other parameters such as the MTF, NNPS and DQE showed a good result as designed. Based on this study, the new X-ray CIS with ~ 50 μm pitch and ~ 150 cm2 active area are going to be designed for the high resolution X-ray NDT equipment for semiconductor and PCB inspections etc.

  18. Modeling the growth of Byssochlamys fulva and Neosartorya fischeri on solidified apple juice by measuring colony diameter and ergosterol content.

    Science.gov (United States)

    Tremarin, Andréia; Longhi, Daniel Angelo; Salomão, Beatriz de Cassia Martins; Aragão, Gláucia Maria Falcão

    2015-01-16

    Byssochlamys fulva and Neosartorya fischeri are heat-resistant fungi which are a concern to food industries (e.g. apple juice industry) since their growth represents significant economic liabilities. Although the most common method used to assess fungal growth in solid substrates is by measuring the colony's diameter, it is difficult to apply this method to food substrates. Alternatively, ergosterol contents have been used to quantify fungal contamination in some types of food. The current study aimed at modeling the growth of the heat-resistant fungi B. fulva and N. fischeri by measuring the colony diameter and ergosterol content, fitting the Baranyi and Roberts model to the results, and finally establishing a correlation between the parameters of the two analytical methods. Whereas the colony diameter was measured daily, the quantification of ergosterol was performed when the colonies reached diameters of 30, 60, 90, 120 and 150 mm. Results showed that B. fulva and N. fischeri were able to grow successfully on solidified apple juice at 10, 15, 20, 25 and 30 °C, and the Baranyi and Roberts model showed good ability to describe growth data. The correlation curves between the parameters of colony diameter and ergosterol content were obtained with satisfactory statistical indexes. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. NEOWISE REACTIVATION MISSION YEAR ONE: PRELIMINARY ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Masiero, J.; Bauer, J.; Kramer, E.; Sonnett, S.; Stevenson, R. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2015-12-01

    We present preliminary diameters and albedos for 7956 asteroids detected in the first year of the NEOWISE Reactivation mission. Of those, 201 are near-Earth asteroids and 7755 are Main Belt or Mars-crossing asteroids. 17% of these objects have not been previously characterized using the Near-Earth Object Wide-field Infrared Survey Explorer, or “NEOWISE” thermal measurements. Diameters are determined to an accuracy of ∼20% or better. If good-quality H magnitudes are available, albedos can be determined to within ∼40% or better.

  20. Specification for modular plug-in unit and standard 19-inch rack mounting unit based on NIM standard (for electronic nuclear instruments)

    International Nuclear Information System (INIS)

    1978-01-01

    The object is to define standard dimensions of a modular system based on NIM standard and comprising the plug-in unit Type N specified in IEC Publication 482, Dimensions of Electronic Instrument Modules (for Nuclear Electronic Instruments), the corresponding 19-inch rack mounting unit Type NC (conforming to IEC Publication 297, Dimensions of Panels and Racks) and the associated connectors. (author)

  1. FACES WITH LARGE DIAMETER ON THE SYMMETRICAL TRAVELING SALESMAN POLYTOPE

    NARCIS (Netherlands)

    SIERKSMA, G; TIJSSEN, GA

    This paper deals with the symmetric traveling salesman polytope and contains three main theorems. The first one gives a new characterization of (non)adjacency. Based on this characterization a new upper bound for the diameter of the symmetric traveling salesman polytope (conjectured to be 2 by M.

  2. Sex determination from femoral head diameters in black Malawians ...

    African Journals Online (AJOL)

    Objectives: To determine the sex of black Malawians from femoral head diameters. Design: A retrospective study on patients investigated in three x-ray departments. Setting: Radiographs were collected from the archives of Queen Elizabeth Central, Chikwawa and Balaka hospitals. Subject: X-ray films of 496 pelves of adult ...

  3. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  4. Ultrasound Assessment of Normal Portal Vein Diameter in ...

    African Journals Online (AJOL)

    Even if the additional use of color and spectral Doppler improves the assessment of patients suspected of having portal hypertension, gray scale assessment of portal vein diameter is corner stone in the initial evaluation. Knowing the normal portal venous dimension in a specified population is so crucial. Methods: This is a ...

  5. Pupil Center as a Function of Pupil Diameter

    DEFF Research Database (Denmark)

    Ahmed, Zaheer; Mardanbegi, Diako; Hansen, Dan Witzner

    2016-01-01

    We investigate the gaze estimation error induced by pupil size changes using simulated data. We investigate the influence of pupil diameter changes on estimated gaze point error obtained by two gaze estimation models. Simulation data show that at wider viewing angles and at small eye...

  6. Individual tree diameter, height, and volume functions for longleaf pine

    Science.gov (United States)

    Carlos A. Gonzalez-Benecke; Salvador A. Gezan; Timothy A. Martin; Wendell P. Cropper; Lisa J. Samuelson; Daniel J. Leduc

    2014-01-01

    Currently, little information is available to estimate individual tree attributes for longleaf pine (Pinus palustris Mill.), an important tree species of the southeastern United States. The majority of available models are local, relying on stem diameter outside bark at breast height (dbh, cm) and not including stand-level parameters. We developed...

  7. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  8. Novel Genetic Loci Associated with Retinal Microvascular Diameter

    NARCIS (Netherlands)

    R.A. Jensen (Richard); X. Sim (Xueling); G.D. Smith; X. Li (Xiaohui); M. Jakobsdottir (Margret); C-Y. Cheng (Ching-Yu); J. Brody (Jennifer); M.F. Cotch (Mary Frances); B. McKnight (Barbara); R. Klein (Ronald); J.J. Wang (Jie Jin); A. Kifley (Annette); T.B. Harris (Tamara); L.J. Launer (Lenore); K.D. Taylor (Kent D.); B.E.K. Klein (Barbara); L.J. Raffel (Leslie); X. Li (Xiang); M.A. Ikram (Arfan); C.C.W. Klaver (Caroline); S.J. van der Lee (Sven); U. Mutlu (Unal); A. Hofman (Albert); A.G. Uitterlinden (André); C. Liu (Chunyu); A. Kraja (Aldi); P. Mitchell (Paul); V. Gudnason (Vilmundur); J.I. Rotter (Jerome I.); E.A. Boerwinkle (Eric); C.M. van Duijn (Cornelia); B.M. Psaty (Bruce); T.Y. Wong (Tien Yin)

    2016-01-01

    textabstractBackground-There is increasing evidence that retinal microvascular diameters are associated with cardiovascular and cerebrovascular conditions. The shared genetic effects of these associations are currently unknown. The aim of this study was to increase our understanding of the genetic

  9. Assessment of vessel diameters for MR brain angiography processed images

    Science.gov (United States)

    Moraru, Luminita; Obreja, Cristian-Dragos; Moldovanu, Simona

    2015-12-01

    The motivation was to develop an assessment method to measure (in)visible differences between the original and the processed images in MR brain angiography as a method of evaluation of the status of the vessel segments (i.e. the existence of the occlusion or intracerebral vessels damaged as aneurysms). Generally, the image quality is limited, so we improve the performance of the evaluation through digital image processing. The goal is to determine the best processing method that allows an accurate assessment of patients with cerebrovascular diseases. A total of 10 MR brain angiography images were processed by the following techniques: histogram equalization, Wiener filter, linear contrast adjustment, contrastlimited adaptive histogram equalization, bias correction and Marr-Hildreth filter. Each original image and their processed images were analyzed into the stacking procedure so that the same vessel and its corresponding diameter have been measured. Original and processed images were evaluated by measuring the vessel diameter (in pixels) on an established direction and for the precise anatomic location. The vessel diameter is calculated using the plugin ImageJ. Mean diameter measurements differ significantly across the same segment and for different processing techniques. The best results are provided by the Wiener filter and linear contrast adjustment methods and the worst by Marr-Hildreth filter.

  10. Uncertainty budget for optical coordinate measurements of circle diameter

    DEFF Research Database (Denmark)

    Morace, Renate Erica; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2004-01-01

    An uncertainty analysis for circle diameter measurements using a coordinate measuring machine (CMM) equipped with an optical probe is presented in this paper. A mathematical model for data evaluation and uncertainty assessment was formulated in accordance with Guide to the Expression of Uncertain...

  11. Determination of perimysial and fascicular diameters of triceps ...

    African Journals Online (AJOL)

    In this study, it was observed that all the muscles studied presented normal histomorphology of a typical skeletal muscle, it was discovered that the biceps brachii muscle from camel aged 7 years had higher and significant value for the perimysial diameter compared to that of cattle. Similarly, it was shown that there is an ...

  12. Retinal vessel diameters and risk of stroke: the Rotterdam Study

    NARCIS (Netherlands)

    Ikram, M. K.; de Jong, F. J.; Bos, M. J.; Vingerling, J. R.; Hofman, A.; Koudstaal, P. J.; de Jong, P. T. V. M.; Breteler, M. M. B.

    2006-01-01

    Retinal vessels may provide information on cerebral vascular pathology, because they share many features with cerebral vessels. A smaller ratio of the retinal arteriolar-to-venular diameters reportedly predicts the risk of stroke. It is unclear if this is due to arteriolar narrowing or venular

  13. Bipartite Diametrical Graphs of Diameter 4 and Extreme Orders

    Directory of Open Access Journals (Sweden)

    Salah Al-Addasi

    2008-01-01

    in which this upper bound is attained, this graph can be viewed as a generalization of the Rhombic Dodecahedron. Then we show that for any ≥2, the graph (2,2 is the unique (up to isomorphism bipartite diametrical graph of diameter 4 and partite sets of cardinalities 2 and 2, and hence in particular, for =3, the graph (6,8 which is just the Rhombic Dodecahedron is the unique (up to isomorphism bipartite diametrical graph of such a diameter and cardinalities of partite sets. Thus we complete a characterization of -graphs of diameter 4 and cardinality of the smaller partite set not exceeding 6. We prove that the neighborhoods of vertices of the larger partite set of (2,2 form a matroid whose basis graph is the hypercube . We prove that any -graph of diameter 4 is bipartite self complementary, thus in particular (2,2. Finally, we study some additional properties of (2,2 concerning the order of its automorphism group, girth, domination number, and when being Eulerian.

  14. Modelling diameter growth, mortality and recruitment of trees in ...

    African Journals Online (AJOL)

    Miombo woodlands cover large areas in Tanzania but very little reliable data on forest dynamics for the woodlands exist. The main objective of this study was to develop a model system describing such dynamics based on easily measurable tree variables. Individual tree diameter growth and mortality models, and ...

  15. Sex differences in diameter of the coronary sinus ostium: Correlation ...

    African Journals Online (AJOL)

    Seventy-four hearts of adult black Kenyans [43 male, 31 females; age range 20 – 70 years] obtained during autopsy at the Department of Human Anatomy, University of Nairobi, Kenya were weighed. The coronary sinus ostium was identified and its transverse and supero-inferior diameters measured in millimeters.

  16. Mountain pine beetle infestations in relation to lodgepole pine diameters

    Science.gov (United States)

    Walter E. Cole; Gene D. Amman

    1969-01-01

    Tree losses resulting from infestation by the mountain pine beetle (Dendroctonus ponderosae Hopkins) were measured in two stands of lodgepole pine (Pinus contorta Dougl.) where the beetle population had previously been epidemic. Measurement data showed that larger diameter trees were infested and killed first. Tree losses...

  17. Height-Diameter Predictive Equations for Rubber ( Hevea ...

    African Journals Online (AJOL)

    Many of the resulting models and curves agreed with silvicultural expectation of sigmoidal growth functions; and can provide dependable cum flexible options of predicting heights, given dbh for many plantation species in Nigeria. Keywords: height-diameter equations, allometric models, predictive equations, sigmoidal ...

  18. Experimental study on strain sensing by small-diameter FBG

    Science.gov (United States)

    Liu, Rong-mei; Li, Qiufeng; Zhu, Lujia; Liang, Dakai

    2016-11-01

    Fiber Bragg grating (FBG) sensors were attractive in various fields for structural health monitoring. Because of their accurate performance and real time response, embedded FBG sensors are promising for strain monitoring in composite materials. As an optical fiber sensor was embedded inside a composite, interface would form around the embedded optical fiber and the host polymer composite. In order to study the influence of the embedded optical fiber to the mechanical character, finite elemental analysis was applied to study the stress distribution inside the composite. Keeping the resin rich area the same size, laminates with optical fibers in different diameters, which were 250 and 125 micrometers, were analyzed. The simulation results represent that stress singularity would occur around the embedded optical fiber. The singularity value for the laminate with optical fiber at 250 micrometer was higher than that with optical fiber at 125 micrometer. Micro- cracks would arise at the stress singularity point. Therefore, the optical fiber in smaller diameter was preferred since the mechanical strength could be higher. Four points bending test was carried out on a steel beam with a small-diameter FBG on the bottom surface. Besides, a strain gauge was stuck on bottom to validate the monitoring results by FBG sensor. The tested results indicated that the strain monitoring results by the small-diameter FBG sensor almost identical with the theoretical ones and what recorded by strain gauge. The maximum testing error for the designed FBG is less than 2% compared with the theoretical one.

  19. Study of tube diameter effect on the burnout

    International Nuclear Information System (INIS)

    Levitan, L.L.; Lantsman, F.P.; Dedneva, E.I.

    1981-01-01

    Effect of a tube diameter d on boundary steam content Xsub(b) is experimentally investigated during unwashed liquid wall film drying in the disperse-ring flow regime. For this purpose systematical experimental investigations of the burnout of the second kind in tubes with diameters of 4, 6 and 12 mm have been carried out as well as the other data relating to burnout in tubes with diameter from 4 to 40 mm are used. The investigations have been carried out at water and steam pressures of 4.9-13.7 MPa and mass velocities from 750 to 5000 kg/m 2 xs. It is elucidated that increase in the tube diameter results in reducing the ranges of pressures and mass velocities at which Xsub(b) is independent of heat flux. Quantity dependence Xsub(b)=f(d) has been obtained as well. The best agreement with data from different experiments is observed when taking into account the effect of d on Xsub(b) by means of the following relation: Xsub(b) is proportional to dsup(-0.25). In this case divergence, as a rule, does not exceed 10% [ru

  20. NEOWISE Reactivation Mission Year Three: Asteroid Diameters and Albedos

    Energy Technology Data Exchange (ETDEWEB)

    Masiero, Joseph R.; Mainzer, A. K.; Kramer, E. [Jet Propulsion Laboratory/California Institute of Technology, 4800 Oak Grove Drive, MS 183-301, Pasadena, CA 91109 (United States); Nugent, C.; Cutri, R. M. [California Institute of Technology, Infrared Processing and Analysis Center, 1200 California Boulevard, Pasadena, CA 91125 (United States); Wright, E. L. [University of California, Los Angeles, CA 90095 (United States); Bauer, J. M. [University of Maryland, College Park, MD 20742 (United States); Grav, T.; Sonnett, S., E-mail: Joseph.Masiero@jpl.nasa.gov [Planetary Science Institute, 1700 E Fort Lowell Road #106, Tucson, AZ 85719 (United States)

    2017-10-01

    The Near-Earth Object Wide-field Infrared Survey Explorer (NEOWISE) reactivation mission has completed its third year of surveying the sky in the thermal infrared for near-Earth asteroids and comets. NEOWISE collects simultaneous observations at 3.4 and 4.6  μ m of solar system objects passing through its field of regard. These data allow for the determination of total thermal emission from bodies in the inner solar system, and thus the sizes of these objects. In this paper, we present thermal model fits of asteroid diameters for 170 NEOs and 6110 Main Belt asteroids (MBAs) detected during the third year of the survey, as well as the associated optical geometric albedos. We compare our results with previous thermal model results from NEOWISE for overlapping sample sets, as well as diameters determined through other independent methods, and find that our diameter measurements for NEOs agree to within 26% (1 σ ) of previously measured values. Diameters for the MBAs are within 17% (1 σ ). This brings the total number of unique near-Earth objects characterized by the NEOWISE survey to 541, surpassing the number observed during the fully cryogenic mission in 2010.

  1. Height-diameter allometry of tropical forest trees

    Science.gov (United States)

    T.R. Feldpausch; L. Banin; O.L. Phillips; T.R. Baker; S.L. Lewis; C.A. Quesada; K. Affum-Baffoe; E.J.M.M. Arets; N.J. Berry; M. Bird; E.S. Brondizio; P de Camargo; J. Chave; G. Djagbletey; T.F. Domingues; M. Drescher; P.M. Fearnside; M.B. Franca; N.M. Fyllas; G. Lopez-Gonzalez; A. Hladik; N. Higuchi; M.O. Hunter; Y. Iida; K.A. Salim; A.R. Kassim; M. Keller; J. Kemp; D.A. King; J.C. Lovett; B.S. Marimon; B.H. Marimon-Junior; E. Lenza; A.R. Marshall; D.J. Metcalfe; E.T.A. Mitchard; E.F. Moran; B.W. Nelson; R. Nilus; E.M. Nogueira; M. Palace; S. Patiño; K.S.-H. Peh; M.T. Raventos; J.M. Reitsma; G. Saiz; F. Schrodt; B. Sonke; H.E. Taedoumg; S. Tan; L. White; H. Woll; J. Lloyd

    2011-01-01

    Tropical tree height-diameter (H:D) relationships may vary by forest type and region making large-scale estimates of above-ground biomass subject to bias if they ignore these differences in stem allometry. We have therefore developed a new global tropical forest database consisting of 39 955 concurrent H and D measurements encompassing 283 sites in 22 tropical...

  2. Prediction and error of baldcypress stem volume from stump diameter

    Science.gov (United States)

    Bernard R. Parresol

    1998-01-01

    The need to estimate the volume of removals occurs for many reasons, such as in trespass cases, severance tax reports, and post-harvest assessments. A logarithmic model is presented for prediction of baldcypress total stem cubic foot volume using stump diameter as the independent variable. Because the error of prediction is as important as the volume estimate, the...

  3. predictive accuracy of transcerebellar diameter in comparison with ...

    African Journals Online (AJOL)

    2014-04-04

    Apr 4, 2014 ... IOMETRIC PARAMETERS FOR GESTATIONAL AGE ESTIMATION AMONG PREGNANT NIGERIAN WOMEN. A. A. Adeyekun ... Objective: To compare the predictive accuracy of foetal trans-cerebellar diameter(TCD) with those of other ... due to increased curvature of the foetus, which affects reliability of ...

  4. Percentile-based Weibull diameter distribution model for Pinus ...

    African Journals Online (AJOL)

    Using a site index equation and stem volume model developed for Pinus kesiya in the Philippines, a yield prediction system was created to predict the volume per ha (VPH) for each diameter class and, subsequently, the total volume of a stand. To evaluate the yield prediction system, the predicted mean VPH for each ...

  5. Multi-diameter pigging: factors affecting the design and selection of pigging tools for multi-diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl [Pipeline Engineering and Supply Co. Ltd., Richmond, NY (United States)

    2009-07-01

    This paper will consider the process involved in pigging tool selection for pipelines with two or more significant internal diameters which require pigging tools capable of negotiating the different internal diameters whilst also carrying out the necessary pipeline cleaning operation. The paper will include an analysis of pipeline features that affect pigging tool selection and then go on to look at other variables that determine the pigging tool design; this will include a step by step guide outlining how the tool is designed, the development of prototype pigs and the importance of testing and validation prior to final deployment in operational pigging programmes. (author)

  6. Fabrication of Cell-Laden Hydrogel Fibers with Controllable Diameters

    Directory of Open Access Journals (Sweden)

    Zhuoqun Cheng

    2017-05-01

    Full Text Available Cell-laden hydrogel fibers are widely used as the fundamental building blocks to fabricate more complex functional three-dimensional (3D structures that could mimic biological tissues. The control on the diameter of the hydrogel fibers is important so as to precisely construct structures in the above 3D bio-fabrication. In this paper, a pneumatic-actuated micro-extrusion system is developed to produce hydrogel fibers based on the crosslinking behavior of sodium alginate with calcium ions. Excellent uniformity has been obtained in the diameters of the fabricated hydrogel fibers as a proportional-integral-derivative (PID control algorithm is applied on the driving pressure control. More importantly, a linear relationship has been obtained between the diameter of hydrogel fiber and the driving pressure. With the help of the identified linear model, we can precisely control the diameter of the hydrogel fiber via the control of the driving pressure. The differences between the measured and designed diameters are within ±2.5%. Finally, the influence of the calcium ions on the viability of the encapsulated cells is also investigated by immersing the cell-laden hydrogel fibers into the CaCl2 bath for different periods of time. LIVE/DEAD assays show that there is little difference among the cell viabilities in each sample. Therefore, the calcium ions utilized in the fabrication process have no impact on the cells encapsulated in the hydrogel fiber. Experimental results also show that the cell viability is 83 ± 2% for each sample after 24 h of culturing.

  7. Measurement error in CT assessment of appendix diameter

    Energy Technology Data Exchange (ETDEWEB)

    Trout, Andrew T.; Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Department of Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-12-15

    Appendiceal diameter continues to be cited as an important criterion for diagnosis of appendicitis by computed tomography (CT). To assess sources of error and variability in appendiceal diameter measurements by CT. In this institutional review board-approved review of imaging and medical records, we reviewed CTs performed in children <18 years of age between Jan. 1 and Dec. 31, 2010. Appendiceal diameter was measured in the axial and coronal planes by two reviewers (R1, R2). One year later, 10% of cases were remeasured. For patients who had multiple CTs, serial measurements were made to assess within patient variability. Measurement differences between planes, within and between reviewers, within patients and between CT and pathological measurements were assessed using correlation coefficients and paired t-tests. Six hundred thirty-one CTs performed in 519 patients (mean age: 10.9 ± 4.9 years, 50.8% female) were reviewed. Axial and coronal measurements were strongly correlated (r = 0.92-0.94, P < 0.0001) with coronal plane measurements significantly larger (P < 0.0001). Measurements were strongly correlated between reviewers (r = 0.89-0.9, P < 0.0001) but differed significantly in both planes (axial: +0.2 mm, P=0.003; coronal: +0.1 mm, P=0.007). Repeat measurements were significantly different for one reviewer only in the axial plane (0.3 mm difference, P<0.05). Within patients imaged multiple times, measured appendix diameters differed significantly in the axial plane for both reviewers (R1: 0.5 mm, P = 0.031; R2: 0.7 mm, P = 0.022). Multiple potential sources of measurement error raise concern about the use of rigid diameter cutoffs for the diagnosis of acute appendicitis by CT. (orig.)

  8. Stand diameter distribution modelling and prediction based on Richards function.

    Directory of Open Access Journals (Sweden)

    Ai-guo Duan

    Full Text Available The objective of this study was to introduce application of the Richards equation on modelling and prediction of stand diameter distribution. The long-term repeated measurement data sets, consisted of 309 diameter frequency distributions from Chinese fir (Cunninghamia lanceolata plantations in the southern China, were used. Also, 150 stands were used as fitting data, the other 159 stands were used for testing. Nonlinear regression method (NRM or maximum likelihood estimates method (MLEM were applied to estimate the parameters of models, and the parameter prediction method (PPM and parameter recovery method (PRM were used to predict the diameter distributions of unknown stands. Four main conclusions were obtained: (1 R distribution presented a more accurate simulation than three-parametric Weibull function; (2 the parameters p, q and r of R distribution proved to be its scale, location and shape parameters, and have a deep relationship with stand characteristics, which means the parameters of R distribution have good theoretical interpretation; (3 the ordinate of inflection point of R distribution has significant relativity with its skewness and kurtosis, and the fitted main distribution range for the cumulative diameter distribution of Chinese fir plantations was 0.4∼0.6; (4 the goodness-of-fit test showed diameter distributions of unknown stands can be well estimated by applying R distribution based on PRM or the combination of PPM and PRM under the condition that only quadratic mean DBH or plus stand age are known, and the non-rejection rates were near 80%, which are higher than the 72.33% non-rejection rate of three-parametric Weibull function based on the combination of PPM and PRM.

  9. Vertebral Artery Diameter and Flow: Nature or Nurture.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  10. Computational identification of genes modulating stem height-diameter allometry.

    Science.gov (United States)

    Jiang, Libo; Ye, Meixia; Zhu, Sheng; Zhai, Yi; Xu, Meng; Huang, Minren; Wu, Rongling

    2016-12-01

    The developmental variation in stem height with respect to stem diameter is related to a broad range of ecological and evolutionary phenomena in trees, but the underlying genetic basis of this variation remains elusive. We implement a dynamic statistical model, functional mapping, to formulate a general procedure for the computational identification of quantitative trait loci (QTLs) that control stem height-diameter allometry during development. Functional mapping integrates the biological principles underlying trait formation and development into the association analysis of DNA genotype and endpoint phenotype, thus providing an incentive for understanding the mechanistic interplay between genes and development. Built on the basic tenet of functional mapping, we explore two core ecological scenarios of how stem height and stem diameter covary in response to environmental stimuli: (i) trees pioneer sunlit space by allocating more growth to stem height than diameter and (ii) trees maintain their competitive advantage through an inverse pattern. The model is equipped to characterize 'pioneering' QTLs (piQTLs) and 'maintaining' QTLs (miQTLs) which modulate these two ecological scenarios, respectively. In a practical application to a mapping population of full-sib hybrids derived from two Populus species, the model has well proven its versatility by identifying several piQTLs that promote height growth at a cost of diameter growth and several miQTLs that benefit radial growth at a cost of height growth. Judicious application of functional mapping may lead to improved strategies for studying the genetic control of the formation mechanisms underlying trade-offs among quantities of assimilates allocated to different growth parts. © 2016 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  11. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    -pile interaction. Hence, a modified expression for the p-y curves for statically loaded piles in sand is proposed in which the initial slope of the p-y curves depends on the depth below the soil surface, the pile diameter and the internal angle of friction. The evaluation is based on three-dimensional numerical...

  12. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  13. Statics of deformable solids

    CERN Document Server

    Bisplinghoff, Raymond L; Pian, Theodore HH

    2014-01-01

    Profusely illustrated exposition of fundamentals of solid mechanics and principles of mechanics, statics, and simple statically indeterminate systems. Covers strain and stress in three-dimensional solids, elementary elasticity, energy principles in solid continuum, and more. 1965 edition.

  14. Solid lubricants: A survey

    Science.gov (United States)

    Campbell, M. E.

    1972-01-01

    A survey is presented of the most recent developments and trends in the field of solid lubrication. Topics discussed include: a history of solid lubrication, lubricating solids, bonded lubricants, new developments, methods of evaluation, environmental effects, application methods, novel materials, and designs for the use of solid lubricants. Excerpts of solid lubricant specifications and a discussion of contact stresses imposed on specimens in three types of test machines used for the evaluation of solid lubricants are presented.

  15. Angular diameters of Magellanic Cloud plantary nebulae. I. Speckle interferometry

    International Nuclear Information System (INIS)

    Wood, P.R.; Bessell, M.S.; Dopita, M.A.

    1986-01-01

    Speckle interferometric angular diameters of Magellanic Cloud planetary nebulae are presented. The mass of ionized gas in each nebula has been derived from the angular diameter and published H-beta line fluxes; the derives masses range from less than 0.006 to more than 0.19 solar mass. The planetary nebulae observed were the brightest in the Magellanic Clouds; consequently, they are all relatively small, young, bright, and dense. They are almost certainly only partially ionized, so that the masses derived for the ionized parts of the nebula are lower limits to the total nebula mass. The properties of the Magellanic Cloud nebulae are compared with those of planetary nebulae at the galactic center. 27 references

  16. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-04-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of old cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed previously. Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in test cast-iron pipe segments. Efforts in the current quarter continued to be focused on Tasks 4-8. Highly valuable lessons were learned from field tests of the 4-inch gas pipe repair robot in cast-iron pipe at Public Service Electric & Gas. (These field tests were conducted and reported previously.) Several design issues were identified which need to be implemented in both the small- and large-diameter repair

  17. The diameter and thermal inertia of 433 Eros

    Science.gov (United States)

    Morrison, D.

    1976-01-01

    Radiometry of Eros at 10 and 20 micrometers demonstrates that the thermal conductivity of the upper centimeter of the surface is approximately as low as that of the moon, suggesting that the asteroid has a regolith of highly porous rocky material. When combined with photoelectric photometry, these infrared measurements yield an effective diameter of Eros at maximum light of 22 plus or minus 2 km and a geometric albedo of 0.18 plus or minus 0.03.

  18. Diameter of common bile duct: what are the predicting factors?

    OpenAIRE

    Atoosa Adibi; Behrooz Givechian

    2007-01-01

    BACKGROUND: This was a study to determine the correlation between the common bile duct (CBD) diameter and demographic data, fasting, and the history of opium addiction.
    METHODS: This was a cross-sectional study on 375 patients (>16 years old) including 219 females and 156 males. They had no evident hepatobiliary or pancreatic disease and underwent abdominopelvic ultrasonography for measurement of their CBD di...

  19. Conditioning a segmented stem profile model for two diameter measurements

    Science.gov (United States)

    Raymond L. Czaplewski; Joe P. Mcclure

    1988-01-01

    The stem profile model of Max and Burkhart (1976) is conditioned for dbh and a second upper stem measurement. This model was applied to a loblolly pine data set using diameter outside bark at 5.3m (i.e., height of 17.3 foot Girard form class) as the second upper stem measurement, and then compared to the original, unconditioned model. Variance of residuals was reduced...

  20. A versatile Czochralski crystal growth system with automatic diameter control

    Science.gov (United States)

    Aggarwal, M. D.; Metzl, R.; Wang, W. S.; Choi, J.

    1995-07-01

    A versatile Czochralski crystal pulling system with automatic diameter control for the growth of nonlinear optical oxide crystals is discussed. Pure and doped bulk single crystals of bismuth silicon oxide (Bi12SiO20) have been successfully grown using this system. The system consists of a regular Czochralski type pulling system with provision for continuous weighing of the growing crystal to provide feedback for power control.

  1. Cost of Czochralski wafers as a function of diameter

    Science.gov (United States)

    Leipold, M. H.; Radics, C.; Kachare, A.

    1980-02-01

    The impact of diameter in the range of 10 to 15 cm on the cost of wafers sliced from Czochralski ingots was analyzed. Increasing silicon waste and decreasing ingot cost with increasing ingot size were estimated along with projected costs. Results indicate a small but continuous decrease in sheet cost with increasing ingot size in this size range. Sheet costs including silicon are projected to be $50 to $60/sq m (1980 $) depending upon technique used.

  2. A study of the heated length to diameter effects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Ho; Baek, Won Pil; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1997-12-31

    An analytical and experimental investigation has been performed on the heated length-to-diameter effect on critical heat flux exit conditions. A L/D correction factor is developed by applying artificial neural network and conventional regression techniques to the KAIST CHF data base. In addition, experiment is being performed to validate the developed L/D correction factor with independent data. Assessment shows that the developed correction factor is promising for practical applications. 6 refs., 8 figs. (Author)

  3. Visual function and retinal vessel diameters during hyperthermia in man

    DEFF Research Database (Denmark)

    Jensen, Bettina Hagström; Bram, Thue; Kappelgaard, Per

    2017-01-01

    .01), a 10.6-mmHg mean reduction in diastolic blood pressure (p vein...... laser ophthalmoscopy was used to measure retinal trunk vessel diameters. Assessment was made at baseline, during hyperthermia and after cooling. RESULTS: The induction of a mean increase in core body temperature of 1.02°C was associated with a 7.15-mmHg mean reduction in systolic blood pressure (p

  4. Hitungan Diameter Pipa pada Sistem Penyediaan Air Minum sederhana

    Directory of Open Access Journals (Sweden)

    Wahyu Widiyanto

    2010-02-01

    Full Text Available Drinking water sector is one of the public services which is connected tightly to poverty decrease. A small community water supply is more suitable if it uses a simple system which does not need sophisticated planning and construction. Nevertheless, hydraulics calculation should be always conducted accurately because it will influence water supply performance. In this case, pipe hydraulics needs more overview because system reliability depends on pipe capacity. This study discusses two methods of pipe diameter calculation at a simple drinking water supply system. For planning assistance, Directorate General Cipta Karya-Public Work Ministry issued Technical Guideline Book for Simple Drinking Water Construction in 2007. One of its chapters discusses about a method to find pipe diameter based on several tables available, but it is not given an explanation about basic theory of the tables so there is a doubt for planners. For the reason, comparison between the use of the tables (Juknis Method and Darcy-Weisbach Formula to calculate pipe diameter will be discussed. Data from 5 villages in Kebumen Regency will be utilized to support analysis. The result of procedure for making comparison shows that there is no significant difference (less than 4% between the result of calculation by Darcy-Weisbach Formula and Juknis Method with accurate interpolation. Both of the methods can be applied with its advantages and disadvantages. It is suggested that Darcy-Weisbach Formula is always implemented to re-check toward pipe diameter which is available in the market and will be used in the system.

  5. Theoretical solid state physics

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    Research activities at ORNL in theoretical solid state physics are described. Topics covered include: surface studies; particle-solid interactions; electronic and magnetic properties; and lattice dynamics

  6. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  7. Tree height–diameter allometry across the United States

    Science.gov (United States)

    Hulshof, Catherine M; Swenson, Nathan G; Weiser, Michael D

    2015-01-01

    The relationship between tree height and diameter is fundamental in determining community and ecosystem structure as well as estimates of biomass and carbon storage. Yet our understanding of how tree allometry relates to climate and whole organismal function is limited. We used the Forest Inventory and Analysis National Program database to determine height–diameter allometries of 2,976,937 individuals of 293 tree species across the United States. The shape of the allometric relationship was determined by comparing linear and nonlinear functional forms. Mixed-effects models were used to test for allometric differences due to climate and floristic (between angiosperms and gymnosperms) and functional groups (leaf habit and shade tolerance). Tree allometry significantly differed across the United States largely because of climate. Temperature, and to some extent precipitation, in part explained tree allometric variation. The magnitude of allometric variation due to climate, however, had a phylogenetic signal. Specifically, angiosperm allometry was more sensitive to differences in temperature compared to gymnosperms. Most notably, angiosperm height was more negatively influenced by increasing temperature variability, whereas gymnosperm height was negatively influenced by decreasing precipitation and increasing altitude. There was little evidence to suggest that shade tolerance influenced tree allometry except for very shade-intolerant trees which were taller for any given diameter. Tree allometry is plastic rather than fixed and scaling parameters vary around predicted central tendencies. This allometric variation provides insight into life-history strategies, phylogenetic history, and environmental limitations at biogeographical scales. PMID:25859325

  8. Tree height-diameter allometry across the United States.

    Science.gov (United States)

    Hulshof, Catherine M; Swenson, Nathan G; Weiser, Michael D

    2015-03-01

    The relationship between tree height and diameter is fundamental in determining community and ecosystem structure as well as estimates of biomass and carbon storage. Yet our understanding of how tree allometry relates to climate and whole organismal function is limited. We used the Forest Inventory and Analysis National Program database to determine height-diameter allometries of 2,976,937 individuals of 293 tree species across the United States. The shape of the allometric relationship was determined by comparing linear and nonlinear functional forms. Mixed-effects models were used to test for allometric differences due to climate and floristic (between angiosperms and gymnosperms) and functional groups (leaf habit and shade tolerance). Tree allometry significantly differed across the United States largely because of climate. Temperature, and to some extent precipitation, in part explained tree allometric variation. The magnitude of allometric variation due to climate, however, had a phylogenetic signal. Specifically, angiosperm allometry was more sensitive to differences in temperature compared to gymnosperms. Most notably, angiosperm height was more negatively influenced by increasing temperature variability, whereas gymnosperm height was negatively influenced by decreasing precipitation and increasing altitude. There was little evidence to suggest that shade tolerance influenced tree allometry except for very shade-intolerant trees which were taller for any given diameter. Tree allometry is plastic rather than fixed and scaling parameters vary around predicted central tendencies. This allometric variation provides insight into life-history strategies, phylogenetic history, and environmental limitations at biogeographical scales.

  9. Optical coating uniformity of 200mm (8") diameter precut wafers

    Science.gov (United States)

    Burt, Travis C.; Fisher, Mark; Brown, Dean; Troiani, David

    2017-02-01

    Automated spectroscopic profiling (mapping) of a 200 mm diameter near infrared high reflector (centered at 1064 nm) are presented. Spatial resolution at 5 mm or less was achieved using a 5 mm × 1.5 mm monochromatic beam. Reflection changes of 1.0% across the wafer diameter were observed under s-polarized and p- polarized conditions. Redundancy was established for each chord by re-measuring the center of the wafer and reproducibility of approximately used to measure the reflectance and transmittance of a sample across a range of angles (θi) at near normal angles of incidence (AOI). A recent development by Agilent Technologies, the Cary 7000 Universal Measurement Spectrophotometer (UMS) combines both reflection and transmission measurements from the same patch of a sample's surface in a single automated platform for angles of incidence in the range 5°use of MPS on the Cary 7000 UMS with rotational (Φ) and vertical (z) sample positioning control. MPS(θi,Φ,z) provides for automated unattended multi-angle R/T analysis of at 200 mm diameter samples with the goal to provide better spectroscopic measurement feedback into large wafer manufacturing to ensure yields are maximized, product quality is better controlled and waste is reduced before further down-stream processing.

  10. Critical Diameter Study of Unconfined Australian Manufactured Composition B, Grades A and B

    National Research Council Canada - National Science Library

    Swinton, R

    1997-01-01

    .... To this end, the critical diameter, which is the minimum diameter which will sustain a stable detonation, and the limiting value of the velocity of detonation at infinite charge diameter D(infinity...

  11. Geometric interpretation of the ratio of overall diameter to rim crest diameter for lunar and terrestrial craters.

    Science.gov (United States)

    Siegal, B. S.; Wickman, F. E.

    1973-01-01

    An empirical linear relationship has been established by Pike (1967) between the overall diameter and the rim crest diameter for rimmed, flat-floored as well as bowl-shaped, lunar and terrestrial craters formed by impact and explosion. A similar relationship for experimentally formed fluidization craters has been established by Siegal (1971). This relationship is examined in terms of the geometry of the crater and the slope angles of loose materials. The parameter varies from 1.40 to 1.65 and is found to be dependent on mean interior flat floor radius, exterior and interior rim slope angles, angle of aperture of the crater cone, and the volume fraction of crater void accounted for in the rim. The range of the observed parameter can be understood in terms of simple crater geometry by realistic values of the five parameters.

  12. 49 CFR 231.24 - Box and other house cars with roofs, 16 feet 10 inches or more above top of rail. 1

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Box and other house cars with roofs, 16 feet 10... APPLIANCE STANDARDS § 231.24 Box and other house cars with roofs, 16 feet 10 inches or more above top of.... Same as specified for “Box and Other House Cars.” (2) Dimensions. Same as specified for “Box and Other...

  13. Calculation of the reaction rate and response matrix of a neutron spectroscopy consisting of a water sphere of variable diameter and BF3 detector using the MCNP5-beta code

    International Nuclear Information System (INIS)

    Albashir, K.; Nahili, M.; Al-Zawahera, S.

    2015-01-01

    The MCNP5-beta code was used to calculate the reaction rate 1 0B(n,α) 7 Li and the neutron energy response matrix of a neutron spectrometer consisting of a water sphere with variable diameter and detector BF 3 using point and disk neutron sources 2 41Am-Be. The reaction rate and the response matrix of disk neutron source shows higher value than these obtained from the point neutron source. The response of the matrix disk neutron source in the energy range from 4.14x10 - 7 to 11.09 MeV show a maximum value for sphere of 12 inch diameter, where the response with point neutron source stile increasing calculated value in this condition .The calculated values of neutron energy responses for a disk neutron source agreed well with published results. (author)

  14. Food intake in relation to pouch volume, stoma diameter, and pouch emptying after gastroplasty for morbid obesity

    DEFF Research Database (Denmark)

    Andersen, T; Pedersen, B H; Henriksen, Jens Henrik Sahl

    1988-01-01

    emptying was determined as the mean transit time by a scintigraphic method. None of the measured variables was found to influence the change in food intake taking place during the first 6 months, when most of the weight loss was observed. Between 6 and 12 months, the change of stoma diameter was positively......This study investigated possible determinants of food intake change after gastroplastry. Preoperatively and 6 and 12 months postoperatively, 27 morbidly obese patients were prospectively examined with 7-day food registration and radiologic measurement of pouch volume and stoma diameter. Pouch...... associated with the change of solid foods consumed (by weight, p = 0.01; by energy content, p = 0.02). The change of pouch volume was negatively associated with the change of energy from beverages (p = 0.005). In conclusion, it seems impossible to tailor the reduction of food intake through adjustments...

  15. Solid lubricants and surfaces

    CERN Document Server

    Braithwaite, E R

    1964-01-01

    Solid Lubricants and Surfaces deals with the theory and use of solid lubricants, particularly in colloidal form. Portions of this book are devoted to graphite and molybdenum disulfides, which are widely used solid lubricants in colloidal form. An extensive literature on the laboratory examination of hundreds of solids as potential lubricants is also provided in this text. Other topics discussed include the metals and solid lubricants; techniques for examining surfaces; other solid lubricants; metal shaping; and industrial uses of solid-lubricant dispersions. This publication is beneficial to e

  16. Fabricated nano-fiber diameter as liquid concentration sensors

    Science.gov (United States)

    Chyad, Radhi M.; Mat Jafri, Mohd Zubir; Ibrahim, Kamarulazizi

    Nanofiber is characterized by thin, long, and very soft silica. Taper fibers are made using an easy and low cost chemical method. Etching is conducted with a HF solution to remove cladding and then a low molarity HF solution to reduce the fiber core diameter. One approach to on-line monitoring of the etching process uses spectrophotometer with a white light source. In the aforementioned technique, this method aims to determine the diameter of the reduced core and show the evolution of the two different processes from the nanofiber regime to the fixed regime in which the mode was remote from the surrounding evanescent field, intensity can propagate outside the segment fiber when the core diameter is less than 500 nm. Manufacturing technologies of nano-fiber sensors offer a number of approved properties of optical fiber sensors utilized in various sensory applications. The nano-fiber sensor is utilized to sense the difference in the concentration of D-glucose in double-distilled deionized water and to measure the refractive index (RI) of a sugar solution. Our proposed method exhibited satisfactory capability based on bimolecular interactions in the biological system. The response of the nano-fiber sensors indicates a different kind of interaction among various groups of AAs. These results can be interpreted in terms of solute-solute and solute-solvent interactions and the structure making or breaking ability of solutes in the given solution. This study utilized spectra photonics to measure the transmission of light through different concentrations of sugar solution, employing cell cumber and nano-optical fibers as sensors.

  17. Corrosion and deposit evaluation in large diameter pipes using radiography

    International Nuclear Information System (INIS)

    Boateng, A.

    2012-01-01

    The reliability and safety of industrial equipment in the factories and processing industries are substantially influenced by degradation processes such as corrosion, erosion, deposits and blocking of pipes. These might lead to low production, unpredictable and costly shutdowns due to repair and replacement and sometimes combined environmental pollution and risk of personnel injuries. Only periodic inspection for the integrity of pipes and equipment can reduce the risk in connection with other maintenance activities. The research explored two methods of radiographic inspection techniques, the double wall technique and the tangential radiographic technique using Ir-192 for evaluating deposits and corrosion attacks across the inner and outer walls of steel pipes with diameter greater than 150 mm with or without insulation. The application of both techniques was conducted depending on pipe diameter, wall thickness, radiation source (Ir-92) and film combination. The iridium source was positioned perpendicular with respect to the pipe axis projecting the double wall of the pipe on the plated radiographic film. With the tangential radiographic technique, the source was placed tangential to the pipe wall and because of its large diameter, the source was collimated to prevent backscatter and also to focus the beam at the target area of interest. All measurements were performed on special designed test pieces to simulate corrosion attack and deposits on industrial pipes. Pitting corrosion measurements based on Tangential Radiographic Technique were more sophisticated, and therefore magnification factor and correction were used to establish the estimated pit depth on the film. The insulating material used to conserve the thermodynamic properties of the transported media had relatively negligible attenuation coefficient compared to the concrete deposit. The two explored techniques were successful in evaluating corrosion attack and deposit on the walls of the pipe and the risk

  18. Radio source orientation and the angular diameter-redshift relation

    Science.gov (United States)

    Onuora, L. I.

    1991-08-01

    The effect of a nonrandom source orientation on the angular diameter-redshift relation was considered for the 3CR sample of Laing et al., based on the 'unified' scheme of Barthel. For an inhomogeneous sample of objects displaying milliarcsecond scale structure, it was found that there was no evidence for a systematic variation for orientation angle with redshift. However, if it was assumed that quasars are closer to the line of sight than powerful extended radio galaxies, then the observed angular size-redshift relation could be interpreted in terms of source orientation, rather than linear size evolution.

  19. Real time observation of ZnO nanostructure formation via the solid-vapor and solid-solid-vapor mechanisms.

    Science.gov (United States)

    Kim, B J; Kim, M W; Jang, J S; Stach, E A

    2014-06-21

    We report in situ transmission electron microscopy studies of the formation of ZnO nanostructures--nanoscale depressions, nanoholes, nanoribbons, and nanosheets--and the phase stability and kinetics of Au catalysts on ZnO. During annealing, the ZnO layer produces hexagonally shaped, vertical nanoscale depressions, which increase in size along the 〈 0001 〉 growth direction through preferential dissociation from the {101[combining macron]0} facet and which subsequently form hexagonal islands at their six-fold junctions. Real time observations of the annealing of Au deposited on ZnO show that the catalysts remain solid up to 900 °C, an observation that has implications regarding ZnO nanowire growth via the vapor-solid-solid mechanism (VSS). The Au also creates hexagonal nanoscale holes only at the location of solid Au catalysts, via the solid-solid-vapor (SSV) mechanism. Importantly, coarsening of the Au particles is negligible due to limited Au diffusion on the side facets of the nanoscale depressions, suggesting an approach to the growth of uniform hybrid nanowires with control over both diameter and location. Furthermore, we directly monitor the evolution of the transformation of a nanoribbon into a nanosheet with {101[combining macron]0} facets. This process takes place through a periodic, kinetic roughening transition of the surface, which is controlled by the kinetic competition between surface growth and the transfer of evaporated gases. In total, these observations give new insights into multiple growth processes occurring in this important materials system.

  20. Polymer blend lithography for metal films: large-area patterning with over 1 billion holes/inch(2).

    Science.gov (United States)

    Huang, Cheng; Förste, Alexander; Walheim, Stefan; Schimmel, Thomas

    2015-01-01

    Polymer blend lithography (PBL) is a spin-coating-based technique that makes use of the purely lateral phase separation between two immiscible polymers to fabricate large area nanoscale patterns. In our earlier work (Huang et al. 2012), PBL was demonstrated for the fabrication of patterned self-assembled monolayers. Here, we report a new method based on the technique of polymer blend lithography that allows for the fabrication of metal island arrays or perforated metal films on the nanometer scale, the metal PBL. As the polymer blend system in this work, a mixture of polystyrene (PS) and poly(methyl methacrylate) (PMMA), dissolved in methyl ethyl ketone (MEK) is used. This system forms a purely lateral structure on the substrate at controlled humidity, which means that PS droplets are formed in a PMMA matrix, whereby both phases have direct contact both to the substrate and to the air interface. Therefore, a subsequent selective dissolution of either the PS or PMMA component leaves behind a nanostructured film which can be used as a lithographic mask. We use this lithographic mask for the fabrication of metal patterns by thermal evaporation of the metal, followed by a lift-off process. As a consequence, the resulting metal nanostructure is an exact replica of the pattern of the selectively removed polymer (either a perforated metal film or metal islands). The minimum diameter of these holes or metal islands demonstrated here is about 50 nm. Au, Pd, Cu, Cr and Al templates were fabricated in this work by metal PBL. The wavelength-selective optical transmission spectra due to the localized surface plasmonic effect of the holes in perforated Al films were investigated and compared to the respective hole diameter histograms.

  1. Polymer blend lithography for metal films: large-area patterning with over 1 billion holes/inch2

    Directory of Open Access Journals (Sweden)

    Cheng Huang

    2015-05-01

    Full Text Available Polymer blend lithography (PBL is a spin-coating-based technique that makes use of the purely lateral phase separation between two immiscible polymers to fabricate large area nanoscale patterns. In our earlier work (Huang et al. 2012, PBL was demonstrated for the fabrication of patterned self-assembled monolayers. Here, we report a new method based on the technique of polymer blend lithography that allows for the fabrication of metal island arrays or perforated metal films on the nanometer scale, the metal PBL. As the polymer blend system in this work, a mixture of polystyrene (PS and poly(methyl methacrylate (PMMA, dissolved in methyl ethyl ketone (MEK is used. This system forms a purely lateral structure on the substrate at controlled humidity, which means that PS droplets are formed in a PMMA matrix, whereby both phases have direct contact both to the substrate and to the air interface. Therefore, a subsequent selective dissolution of either the PS or PMMA component leaves behind a nanostructured film which can be used as a lithographic mask. We use this lithographic mask for the fabrication of metal patterns by thermal evaporation of the metal, followed by a lift-off process. As a consequence, the resulting metal nanostructure is an exact replica of the pattern of the selectively removed polymer (either a perforated metal film or metal islands. The minimum diameter of these holes or metal islands demonstrated here is about 50 nm. Au, Pd, Cu, Cr and Al templates were fabricated in this work by metal PBL. The wavelength-selective optical transmission spectra due to the localized surface plasmonic effect of the holes in perforated Al films were investigated and compared to the respective hole diameter histograms.

  2. Tunable engineered skin mechanics via coaxial electrospun fiber core diameter.

    Science.gov (United States)

    Blackstone, Britani Nicole; Drexler, Jason William; Powell, Heather Megan

    2014-10-01

    Autologous engineered skin (ES) offers promise as a treatment for massive full thickness burns. Unfortunately, ES is orders of magnitude weaker than normal human skin causing it to be difficult to apply surgically and subject to damage by mechanical shear in the early phases of engraftment. In addition, no manufacturing strategy has been developed to tune ES biomechanics to approximate the native biomechanics at different anatomic locations. To enhance and tune ES biomechanics, a coaxial (CoA) electrospun scaffold platform was developed from polycaprolactone (PCL, core) and gelatin (shell). The ability of the coaxial fiber core diameter to control both scaffold and tissue mechanics was investigated along with the ability of the gelatin shell to facilitate cell adhesion and skin development compared to pure gelatin, pure PCL, and a gelatin-PCL blended fiber scaffold. CoA ES exhibited increased cellular adhesion and metabolism versus PCL alone or gelatin-PCL blend and promoted the development of well stratified skin with a dense dermal layer and a differentiated epidermal layer. Biomechanics of the scaffold and ES scaled linearly with core diameter suggesting that this scaffold platform could be utilized to tailor ES mechanics for their intended grafting site and reduce graft damage in vitro and in vivo.

  3. The Use of Narrow Diameter Implants in the Molar Area

    Directory of Open Access Journals (Sweden)

    M. Saad

    2016-01-01

    Full Text Available Implant rehabilitations in the posterior jaw are influenced by many factors such as the condition of the remaining teeth, the force factors related to the patient, the quality of the bone, the maintenance of the hygiene, the limited bone height, the type and extent of edentulism, and the nature of the opposing arch. The gold standard is to place a regular diameter implant (>3.7 mm or a wide one to replace every missing molar. Unfortunately, due to horizontal bone resorption, this option is not possible without lateral bone augmentation. In this situation, narrow diameter implant (NDI < 3.5 mm could be the alternative to lateral bone augmentation procedures. This paper presents a clinical study where NDIs were used for the replacement of missing molars. They were followed up to 11 years. Special considerations were observed and many parameters were evaluated. NDI could be used to replace missing molar in case of moderate horizontal bone resorption if strict guidelines are respected. Yet, future controlled prospective clinical trials are required to admit their use as scientific evidence.

  4. Carbon microtubes: tuning internal diameters and conical angles.

    Science.gov (United States)

    Bhimarasetti, Gopinath; Cowley, John M; Sunkara, Mahendra K

    2005-07-01

    In this paper, we report a synthesis strategy for a new class of hollow, curved carbon morphologies, 'carbon microtubes' (CMTs), with absolute control over their conical angles and internal diameters. Our synthesis methodology employs nitrogen or oxygen dosing to change the wetting behaviour of gallium metal with the growing carbon walls to tune the conical angles. Increasing N(2) concentrations in the gas phase during growth increases the conical angles of CMTs from +25° to about -20°. A methodology using the timing of oxygen or nitrogen dosing during CMT growth is shown to tune the internal diameters anywhere from a few nanometres to a few microns. The walls of the carbon microtubes are characterized using transmission electron microscopy (TEM) and Raman spectroscopy and are found to consist of aligned graphite nanocrystals (2-5 nm in size). Furthermore, dark field images of CMTs showed that the graphite nanocrystals are aligned with their c-axes perpendicular to the wall surface and that the crystals themselves are oriented with respect to the wall surface depending upon the conical angle of the CMT.

  5. Muscle fiber diameter assessment in cleft lip using image processing.

    Science.gov (United States)

    Khan, M F J; Little, J; Abelli, L; Mossey, P A; Autelitano, L; Nag, T C; Rubini, M

    2018-04-01

    To pilot investigation of muscle fiber diameter (MFD) on medial and lateral sides of the cleft in 18 infants with cleft lip with or without cleft palate (CL/P) using image processing. Formalin-fixed paraffin-embedded (FFPE) tissue samples from the medial and lateral sides of the cleft were analyzed for MFD using an image-processing program (ImageJ). For within-case comparison, a paired Student's t test was performed. For comparisons between classes, an unpaired t test was used. Image processing enabled rapid measurement of MFD with majority of fibers showing diameter between 6 and 11 μm. There was no significant difference in mean MFD between the medial and lateral sides, or between CL and CLP. However, we found a significant difference on the medial side (p = .032) between males and females. The image processing on FFPE tissues resulted in easy quantification of MFD with finding of a smaller MFD on the medial side in males suggesting possible differences in orbicularis oris (OO) muscle between the two sexes in CL that warrants replication using larger number of cases. Moreover, this finding can aid subclinical phenotyping and potentially in the restoration of the anatomy and function of the upper lip. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  6. Diameter of titanium nanotubes influences anti-bacterial efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Ercan, Batur; Taylor, Erik; Webster, Thomas J [School of Engineering, Brown University, Providence, RI 02917 (United States); Alpaslan, Ece, E-mail: thomas_webster@brown.edu [Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul (Turkey)

    2011-07-22

    Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.

  7. Unobtrusively tracking mammographers' eye gaze direction and pupil diameter

    Science.gov (United States)

    Barrett, James R.; deParedes, Ellen S.; Dwyer, Samuel J., III; Merickel, Michael B.; Hutchinson, Thomas E.

    1994-04-01

    We developed techniques to unobtrusively track direction and pupil diameter of radiologists reading a wide variety of films. This study concentrated on mammography since the use of mammograms is important for successful treatment of breast cancer, and we wished to determine how previous studies of eye gaze with lung films relate to the specialized field of mammography. Our objective was to identify eye gaze patterns in mammographic experts as they observe features, such as masses and microcalcification clusters: identification of these patterns could lead to improving the rate of early detection of breast cancer. Our near IR light system successfully tracked eye gaze direction and pupil diameter of mammographic experts evaluating films. The association of long eye gaze dwells with diagnostic accuracy varied with the type of object being viewed. In films with masses, false positive diagnoses were associated with long dwells: this is similar to published results of observing lung nodule diagnosis. In mammograms with microcalcifications, true positive diagnoses were associated with long dwells. The association of prolonged dwells with true positive diagnoses of microcalcifications is a new observation.

  8. MODELING AND DESIGN OF INNOVATIVE SMALL DIAMETER GRAVITY SEWERAGE SYSTEM

    Directory of Open Access Journals (Sweden)

    Tadeusz Nawrot

    2017-05-01

    Full Text Available The article presents modern methods of hydraulic design of an innovative small diameter gravity sewerage system. In this system, domestic wastewater is preliminary treated in septic tanks equipped with outlet filters, thus the effluent features are similar to those of clear water. Innovative non-return valves at the outlets eliminate introduction of air to the system and thus the flows can be treated as one-phase ones. Computer codes EPANET 2 and SWMM 5.0 were applied and compared. Two flow schemes typical for the sewerage system were implemented in EPANET 2, and the third - in a slightly modified SWMM 5.0. Simulation results were validated on empirical data obtained on a laboratory physical model, consisting of four tanks of minimum volumes 600 dm3 each, connecting PE pipelines of diameters 25 mm and 36 mm and relevant sanitary fittings. Water inflows, typical for domestic wastewater outflows from single homesteads, were provided by a pump. Water flows were measured using water meters with pulse outputs, and water levels in tanks by pressure transducers. Hydraulic characteristics of filters and non-return valves were provided. Simulation results showed good agreement with the empirical data. Ranges of values of design parameters, needed for successful application of both codes, were established and discussed.

  9. Diameter of titanium nanotubes influences anti-bacterial efficacy

    Science.gov (United States)

    Ercan, Batur; Taylor, Erik; Alpaslan, Ece; Webster, Thomas J.

    2011-07-01

    Bacterial infection of in-dwelling medical devices is a growing problem that cannot be treated by traditional antibiotics due to the increasing prevalence of antimicrobial resistance and biofilm formation. Here, due to changes in surface parameters, it is proposed that bacterial adhesion can be prevented through nanosurface modifications of the medical device alone. Toward this goal, titanium was created to possess nanotubular surface topographies of highly controlled diameters of 20, 40, 60, or 80 nm, sometimes followed by heat treatment to control chemistry and crystallinity, through a novel anodization process. For the first time it was found that through the control of Ti surface parameters including chemistry, crystallinity, nanotube size, and hydrophilicity, significantly changed responses of both Staphylococcus epidermidis and Staphylococcus aureus (pathogens relevant for orthopaedic and other medical device related infections) were measured. Specifically, heat treatment of 80 nm diameter titanium tubes produced the most robust antimicrobial effect of all surface treatment parameters tested. This study provides the first step toward understanding the surface properties of nano-structured titanium that improve tissue growth (as has been previously observed with nanotubular titanium), while simultaneously reducing infection without the use of pharmaceutical drugs.

  10. Threshold Particle Diameters in Miniemulsion Reversible-Deactivation Radical Polymerization

    Directory of Open Access Journals (Sweden)

    Hidetaka Tobita

    2011-11-01

    Full Text Available Various types of controlled/living radical polymerizations, or using the IUPAC recommended term, reversible-deactivation radical polymerization (RDRP, conducted inside nano-sized reaction loci are considered in a unified manner, based on the polymerization rate expression, Rp = kp[M]K[Interm]/[Trap]. Unique miniemulsion polymerization kinetics of RDRP are elucidated on the basis of the following two factors: (1 A high single molecule concentration in a nano-sized particle; and (2 a significant statistical concentration variation among particles. The characteristic particle diameters below which the polymerization rate start to deviate significantly (1 from the corresponding bulk polymerization, and (2 from the estimate using the average concentrations, can be estimated by using simple equations. For stable-radical-mediated polymerization (SRMP and atom-transfer radical polymerization (ATRP, an acceleration window is predicted for the particle diameter range, . For reversible-addition-fragmentation chain-transfer polymerization (RAFT, degenerative-transfer radical polymerization (DTRP and also for the conventional nonliving radical polymerization, a significant rate increase occurs for . On the other hand, for  the polymerization rate is suppressed because of a large statistical variation of monomer concentration among particles.

  11. Solid state physics

    CERN Document Server

    Burns, Gerald

    2013-01-01

    Solid State Physics, International Edition covers the fundamentals and the advanced concepts of solid state physics. The book is comprised of 18 chapters that tackle a specific aspect of solid state physics. Chapters 1 to 3 discuss the symmetry aspects of crystalline solids, while Chapter 4 covers the application of X-rays in solid state science. Chapter 5 deals with the anisotropic character of crystals. Chapters 6 to 8 talk about the five common types of bonding in solids, while Chapters 9 and 10 cover the free electron theory and band theory. Chapters 11 and 12 discuss the effects of moveme

  12. Theoretical solid state physics

    CERN Document Server

    Haug, Albert

    2013-01-01

    Theoretical Solid State Physics, Volume 1 focuses on the study of solid state physics. The volume first takes a look at the basic concepts and structures of solid state physics, including potential energies of solids, concept and classification of solids, and crystal structure. The book then explains single-electron approximation wherein the methods for calculating energy bands; electron in the field of crystal atoms; laws of motion of the electrons in solids; and electron statistics are discussed. The text describes general forms of solutions and relationships, including collective electron i

  13. Development of well logging neutron tube with diameter 22 mm

    International Nuclear Information System (INIS)

    Xiao Kunxiang; Xiang Wei; Mei Lin; Liang Chuan

    2014-01-01

    The structure design and performance of well logging neutron tube with diameter 22 mm are introduced. The ion source of neutron tube is penning ion source, the alnico is placed in the elicitation cathode which make the ion densely and concentration in elicitation hole. The single electrode is used in ion optics and the resistor is used in target electrode, which increase the stably performances of neutron tube. The discharge current is over 200 microampere when pressure is 10 -2 Pa in ion source and the neutron output is over l.5 × lO 8 neutron per second. The well logging neutron tube has good characteristics, such as small volume, enduring high temperature, high neutron yield etc. The development neutron tube can be used in well logging in oil field. (authors)

  14. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    for the radial and dorsalis pedis artery was 22 +/- 3 and 28 +/- 3% lower during handgrip than the relation during rest, respectively. After one-leg knee extension both arteries reached 30 +/- 4% lower values. This study demonstrated arterial constriction in the resting limbs within the first 30 s of static......In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... of another limb. Static exercise increased heart rate and mean arterial pressure, which were largest during one-leg knee extension. After exercise heart rate and mean arterial pressure returned to the resting level. No changes were recorded in arterial carbon dioxide tension, and the rate of perceived...

  15. Integrated spectral study of small angular diameter galactic open clusters

    Science.gov (United States)

    Clariá, J. J.; Ahumada, A. V.; Bica, E.; Pavani, D. B.; Parisi, M. C.

    2017-10-01

    This paper presents flux-calibrated integrated spectra obtained at Complejo Astronómico El Leoncito (CASLEO, Argentina) for a sample of 9 Galactic open clusters of small angular diameter. The spectra cover the optical range (3800-6800 Å), with a resolution of ˜14 Å. With one exception (Ruprecht 158), the selected clusters are projected into the fourth Galactic quadrant (282o evaluate their membership status. The current cluster sample complements that of 46 open clusters previously studied by our group in an effort to gather a spectral library with several clusters per age bin. The cluster spectral library that we have been building is an important tool to tie studies of resolved and unresolved stellar content.

  16. Design of a hot clamp for small diameter LMFBR piping

    International Nuclear Information System (INIS)

    Jones, J.W.; Hamel, D.

    1980-01-01

    In order to evaluate the feasibility of using a strap-type clamp on breeder reactor small diameter piping, a series of analyses were conducted to determine the thermal and mechanical stresses induced in the pipe by the clamp. The effect of using a thin layer of insulation of varying thickness between the pipe and clamp was also investigated. A thermal analysis of the pipe and clamp was conducted for each thermal transient rate. Various insulation values ranging from metal-to-metal condition to perfect insulation between the pipe and clamp were analyzed to determine the effect of insulating the pipe from the clamp. An axisymmetric finite element model was used to determine the axial thermal and stress patterns

  17. Evaluation of crown mesiodistal diameter of permanent teeth

    Directory of Open Access Journals (Sweden)

    H. Ravanmehr

    1994-06-01

    Full Text Available The aim of this study was to evaluate mesiodistal diameter of permanent teeth and evaluating it's distribution in Iran. In current study, 850 plastery impressions or 16590 teeth were precisely measured by a digital coulis with 0.01 mm accuracy.The obtained measures of the permanent teeth are shown in table 1. Table (4 demonstrates the symmetry of left and right maxillary and mandibular teeth. Obtainedmeasurements in Table 1 were compared with Gran's measures (Table 2 which are shown in Table (3.Bolton analysis was done and results were found close to the BolType text or a website address or translate a document.ton measures. It was concluded that it is better to replace measurements of our society instead of Bolton's. Since we found minor difference with the measures of other researchers, especially for teeth anterior to first molar, using our measures in treatment plans would not bring about any problem.

  18. Modifying Thermal Transport in Colloidal Nanocrystal Solids with Surface Chemistry.

    Science.gov (United States)

    Liu, Minglu; Ma, Yuanyu; Wang, Robert Y

    2015-12-22

    We present a systematic study on the effect of surface chemistry on thermal transport in colloidal nanocrystal (NC) solids. Using PbS NCs as a model system, we vary ligand binding group (thiol, amine, and atomic halides), ligand length (ethanedithiol, butanedithiol, hexanedithiol, and octanedithiol), and NC diameter (3.3-8.2 nm). Our experiments reveal several findings: (i) The ligand choice can vary the NC solid thermal conductivity by up to a factor of 2.5. (ii) The ligand binding strength to the NC core does not significantly impact thermal conductivity. (iii) Reducing the ligand length can decrease the interparticle distance, which increases thermal conductivity. (iv) Increasing the NC diameter increases thermal conductivity. (v) The effect of surface chemistry can exceed the effect of NC diameter and becomes more pronounced as NC diameter decreases. By combining these trends, we demonstrate that the thermal conductivity of NC solids can be varied by an overall factor of 4, from ∼0.1-0.4 W/m-K. We complement these findings with effective medium approximation modeling and identify thermal transport in the ligand matrix as the rate-limiter for thermal transport. By combining these modeling results with our experimental observations, we conclude that future efforts to increase thermal conductivity in NC solids should focus on the ligand-ligand interface between neighboring NCs.

  19. Design of small diameter HT/HP sour service reeled rigid pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Daniel; Gouveia, Joao; Tardelli, Luciano [Tecnitas, Rio de Janeiro, RJ (Brazil)], e-mail: daniel.carneiro@br.bureauveritas.com; Parrilha, Rafael [Bureau Veritas Group, London (United Kingdom); Oazen, Eduardo; Cardoso, Carlos [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    The paper presents an overview of the challenges overcome in the engineering design of two 219 mm diameter, 6 km length oil production pipelines, to be installed by reeling at Espirito Santo Basin, offshore Brazilian coast in 1500 m water depth. The high temperature and high pressure (HT/HP) operating conditions and sour content associated with the small diameter required to single well oil production would usually lead to flexible flow line solution in Brazilian fields. The decision of employing small diameter thick-walled rigid C-Mn steel pipelines with thick thermal insulation made necessary extensive engineering work to achieve a safe and robust thermal expansion control arrangement, including the design of walking mitigation and buckle initiation apparatus; a feasible weld acceptance criterion covering both high cycle fatigue due to pipe lay and vortex induced vibration (VIV) at free spans, and high strain low cycle fatigue and fracture growth induced by reeling installation and in-service lateral buckling. Several studies were performed using highly non-linear three-dimensional finite element models considering: pipe-soil interaction with full 3D seabed bathymetry; load history maintained from pipe lay to operational cycles, including temperature transient effects; high plastic strains (including steel properties de-rating due to high temperature) and section ovalization; mechanical contact between pipe and appurtenances during both installation and operational phases. Pipe-soil interaction comprised embedment considering dynamic effects of pipe lay and full non-linear lateral and axial response curves including break-out and residual resistance. Strain concentration factors due to field joints were evaluated using detailed solid models considering non-linear response of both steel and insulation materials. Susceptibility to VIV at free spans was assessed considering post loaded deformed span natural frequencies, including multi-span interaction effects and

  20. Solid phase radioimmunoassays

    International Nuclear Information System (INIS)

    Wide, L.

    1977-01-01

    Solid phase coupled antibodies were introduced to facilitate the separation of bound and free labelled ligand in the competitive inhibition radioimmunoassay. Originally, the solid matrix used was in the form of small particles and since then a number of different matrices have been used such as very fine powder particles, gels, paper and plastic discs, magnetic particles and the inside surface of plastic tubes. The coupling of antibodies may be that of a covalent chemical binding, a strong physical adsorbtion, or an immunological binding to a solid phase coupled antigen. New principles of radioimmunoassay such as the solid phase sandwich techniques and the immunoradiometric assay were developped from the use of solid phase coupled antigens and antibodies. The solid phase sandwich techniques are reagent excess methods with a very wide applicability. Several of the different variants of solid phase techniques are suitable for automation. Advantages and disadvantages of solid phase radioimmunoassays when compared with those using soluble reagents are discussed. (orig.) [de

  1. The Prediction Methods for Potential Suspended Solids Clogging Types during Managed Aquifer Recharge

    Directory of Open Access Journals (Sweden)

    Xinqiang Du

    2014-04-01

    Full Text Available The implementation and development of managed aquifer recharge (MAR have been limited by the clogging attributed to physical, chemical, and biological reactions. In application field of MAR, physical clogging is usually the dominant type. Although numerous studies on the physical clogging mechanism during MAR are available, studies on the more detailed suspended clogging types and its prediction methods still remain few. In this study, a series of column experiments were inducted to show the process of suspended solids clogging process. The suspended solids clogging was divided into three types of surface clogging, inner clogging and mixed clogging based on the different clogging characteristics. Surface clogging indicates that the suspended solids are intercepted by the medium surface when suspended solids grain diameter is larger than pore diameter of infiltration medium. Inner clogging indicates that the suspended solids particles could transport through the infiltration medium. Mixed clogging refers to the comprehensive performance of surface clogging and inner clogging. Each suspended solids clogging type has the different clogging position, different changing laws of hydraulic conductivity and different deposition profile of suspended solids. Based on the experiment data, the ratio of effective medium pore diameter (Dp and median grain size of suspended solids (d50 was proposed as the judgment index for suspended solids clogging types. Surface clogging occurred while Dp/d50 was less than 5.5, inner clogging occurred while Dp/d50 was greater than 180, and mixed clogging occurred while Dp/d50 was between 5.5 and 180. In order to improve the judgment accuracy and applicability, Bayesian method, which considered more ratios of medium pore diameter (Dp and different level of grain diameter of suspended solids (di, were developed to predict the potential suspended solids types.

  2. Analysis of risk and dose when using thermal protection on non-fissile and fissile-excepted UF6 48-inch cylinder packages

    International Nuclear Information System (INIS)

    Chambers, D.B.; Lowe, L.M.; Elizabeth Darrough, M.; Jones, R.H.

    2004-01-01

    An industry consortium of owners of large (i.e., the 48-inch or 48X and 48Y) cylinders commissioned an independent study to evaluate the safety of using thermal protective covers on the cylinders and the likelihood that the cylinders would experience the regulations' hypothetical thermal accident. The study examined the demonstrable risks of the protective covers, i.e., increased dose to workers and the potential for accidents associated with the extra handling, vs. the theoretical risk of the UF 6 cylinders' encountering the hypothetical fire, to evaluate the appropriateness of using the thermal protective covers

  3. Laser cooling of solids

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, Richard I [Los Alamos National Laboratory; Sheik-bahae, Mansoor [UNM

    2008-01-01

    We present an overview of solid-state optical refrigeration also known as laser cooling in solids by fluorescence upconversion. The idea of cooling a solid-state optical material by simply shining a laser beam onto it may sound counter intuitive but is rapidly becoming a promising technology for future cryocooler. We chart the evolution of this science in rare-earth doped solids and semiconductors.

  4. High burn rate solid composite propellants

    Science.gov (United States)

    Manship, Timothy D.

    High burn rate propellants help maintain high levels of thrust without requiring complex, high surface area grain geometries. Utilizing high burn rate propellants allows for simplified grain geometries that not only make production of the grains easier, but the simplified grains tend to have better mechanical strength, which is important in missiles undergoing high-g accelerations. Additionally, high burn rate propellants allow for a higher volumetric loading which reduces the overall missile's size and weight. The purpose of this study is to present methods of achieving a high burn rate propellant and to develop a composite propellant formulation that burns at 1.5 inches per second at 1000 psia. In this study, several means of achieving a high burn rate propellant were presented. In addition, several candidate approaches were evaluated using the Kepner-Tregoe method with hydroxyl terminated polybutadiene (HTPB)-based propellants using burn rate modifiers and dicyclopentadiene (DCPD)-based propellants being selected for further evaluation. Propellants with varying levels of nano-aluminum, nano-iron oxide, FeBTA, and overall solids loading were produced using the HTPB binder and evaluated in order to determine the effect the various ingredients have on the burn rate and to find a formulation that provides the burn rate desired. Experiments were conducted to compare the burn rates of propellants using the binders HTPB and DCPD. The DCPD formulation matched that of the baseline HTPB mix. Finally, GAP-plasticized DCPD gumstock dogbones were attempted to be made for mechanical evaluation. Results from the study show that nano-additives have a substantial effect on propellant burn rate with nano-iron oxide having the largest influence. Of the formulations tested, the highest burn rate was a 84% solids loading mix using nano-aluminum nano-iron oxide, and ammonium perchlorate in a 3:1(20 micron: 200 micron) ratio which achieved a burn rate of 1.2 inches per second at 1000

  5. Experimental study of the viscosity of suspensions: effect of solid fraction, particle size and suspending liquid

    NARCIS (Netherlands)

    Konijn, B.J.; Sanderink, O.B.J.; Kruyt, Nicolaas P.

    2014-01-01

    The behaviour of nearly neutrally-buoyant suspensions has been studied experimentally, using a concentric-cylinder rheometer. The effect on the suspension viscosity of: (i) solid fraction, (ii) diameter of the solid, spherical particles, (iii) viscosity of the suspending liquid, and (iv) shear rate

  6. Buckling Test Results from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA01. [Test Dates: 19-21 November 2008

    Science.gov (United States)

    Hilburger, Mark W.; Waters, W. Allen, Jr.; Haynie, Waddy T.

    2015-01-01

    Results from the testing of cylinder test article SBKF-P2-CYLTA01 (referred to herein as TA01) are presented. The testing was conducted at the Marshall Space Flight Center (MSFC), November 19?21, 2008, in support of the Shell Buckling Knockdown Factor (SBKF) Project.i The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF project researchers. TA01 is an 8-foot-diameter (96-inches), 78.0-inch long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch vehicle structures and was designed to exhibit global buckling when subjected to compression loads. Five different load sequences were applied to TA01 during testing and included four sub-critical load sequences, i.e., loading conditions that did not cause buckling or material failure, and one final load sequence to buckling and collapse. The sub-critical load sequences consisted of either uniform axial compression loading or combined axial compression and bending and the final load sequence subjected TA01 to uniform axial compression. Traditional displacement transducers and strain gages were used to monitor the test article response at nearly 300 locations and an advanced digital image correlation system was used to obtain low-speed and high-speed full-field displacement measurements of the outer surface of the test article. Overall, the test facility and test article performed as designed. In particular, the test facility successfully applied all desired load combinations to the test article and was able to test safely into the postbuckling range of loading, and the test article failed by global buckling. In addition, the test results correlated well with initial pretest predictions.

  7. Aerial Photography and Imagery, Ortho-Corrected, 4 inch aerial photography (color, infrared, and color oblique) in urban areas, 1 foot in national forest, Published in 2006, 1:600 (1in=50ft) scale, Los Angeles County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Aerial Photography and Imagery, Ortho-Corrected dataset current as of 2006. 4 inch aerial photography (color, infrared, and color oblique) in urban areas, 1 foot in...

  8. Aerial Photography and Imagery, Ortho-Corrected, Spring 2006 - natural color - countywide 12 inch pixel orthophotography - County of Polk, Wisconsin, Published in 2006, 1:2400 (1in=200ft) scale, Polk County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Aerial Photography and Imagery, Ortho-Corrected dataset current as of 2006. Spring 2006 - natural color - countywide 12 inch pixel orthophotography - County of Polk,...

  9. Aerial Photography and Imagery, Ortho-Corrected, Six-inch orthoimagery of Washburn County, Wisconsin. The imagery was collected May 5, 2004 by ImageAmerica, Published in 2004, 1:4800 (1in=400ft) scale, Washburn County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Aerial Photography and Imagery, Ortho-Corrected dataset current as of 2004. Six-inch orthoimagery of Washburn County, Wisconsin. The imagery was collected May 5,...

  10. Solid State Division

    International Nuclear Information System (INIS)

    Green, P.H.; Watson, D.M.

    1989-08-01

    This report contains brief discussions on work done in the Solid State Division of Oak Ridge National Laboratory. The topics covered are: Theoretical Solid State Physics; Neutron scattering; Physical properties of materials; The synthesis and characterization of materials; Ion beam and laser processing; and Structure of solids and surfaces

  11. Solid State Division

    Energy Technology Data Exchange (ETDEWEB)

    Green, P.H.; Watson, D.M. (eds.)

    1989-08-01

    This report contains brief discussions on work done in the Solid State Division of Oak Ridge National Laboratory. The topics covered are: Theoretical Solid State Physics; Neutron scattering; Physical properties of materials; The synthesis and characterization of materials; Ion beam and laser processing; and Structure of solids and surfaces. (LSP)

  12. Solid state radiation dosimetry

    International Nuclear Information System (INIS)

    Moran, P.R.

    1976-01-01

    Important recent developments provide accurate, sensitive, and reliable radiation measurements by using solid state radiation dosimetry methods. A review of the basic phenomena, devices, practical limitations, and categories of solid state methods is presented. The primary focus is upon the general physics underlying radiation measurements with solid state devices

  13. Carbon-based strong solid acid for cornstarch hydrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Nata, Iryanti Fatyasari, E-mail: yanti_tkunlam@yahoo.com [Chemical Engineering Study Program, Faculty of Engineering, Lambung Mangkurat University, Jl. A. Yani Km. 36 Banjarbaru, South Kalimantan 70714 (Indonesia); Irawan, Chairul; Mardina, Primata [Chemical Engineering Study Program, Faculty of Engineering, Lambung Mangkurat University, Jl. A. Yani Km. 36 Banjarbaru, South Kalimantan 70714 (Indonesia); Lee, Cheng-Kang, E-mail: cklee@mail.ntust.edu.tw [Department of Chemical Engineering, National Taiwan University of Science and Technology, 43 Keelung Rd. Sec.4, Taipei 106, Taiwan (China)

    2015-10-15

    Highly sulfonated carbonaceous spheres with diameter of 100–500 nm can be generated by hydrothermal carbonization of glucose in the presence of hydroxyethylsulfonic acid and acrylic acid at 180 °C for 4 h. The acidity of the prepared carbonaceous sphere C4-SO{sub 3}H can reach 2.10 mmol/g. It was used as a solid acid catalyst for the hydrolysis of cornstarch. Total reducing sugar (TRS) concentration of 19.91 mg/mL could be obtained by hydrolyzing 20 mg/mL cornstarch at 150 °C for 6 h using C4-SO{sub 3}H as solid acid catalyst. The solid acid catalyst demonstrated good stability that only 9% decrease in TRS concentration was observed after five repeat uses. The as-prepared carbon-based solid acid catalyst can be an environmentally benign replacement for homogeneous catalyst. - Highlights: • Carbon solid acid was successfully prepared by one-step hydrothermal carbonization. • The acrylic acid as monomer was effectively reduce the diameter size of particle. • The solid acid catalyst show good catalytic performance of starch hydrolysis. • The solid acid catalyst is not significantly deteriorated after repeated use.

  14. Carbon-based strong solid acid for cornstarch hydrolysis

    International Nuclear Information System (INIS)

    Nata, Iryanti Fatyasari; Irawan, Chairul; Mardina, Primata; Lee, Cheng-Kang

    2015-01-01

    Highly sulfonated carbonaceous spheres with diameter of 100–500 nm can be generated by hydrothermal carbonization of glucose in the presence of hydroxyethylsulfonic acid and acrylic acid at 180 °C for 4 h. The acidity of the prepared carbonaceous sphere C4-SO 3 H can reach 2.10 mmol/g. It was used as a solid acid catalyst for the hydrolysis of cornstarch. Total reducing sugar (TRS) concentration of 19.91 mg/mL could be obtained by hydrolyzing 20 mg/mL cornstarch at 150 °C for 6 h using C4-SO 3 H as solid acid catalyst. The solid acid catalyst demonstrated good stability that only 9% decrease in TRS concentration was observed after five repeat uses. The as-prepared carbon-based solid acid catalyst can be an environmentally benign replacement for homogeneous catalyst. - Highlights: • Carbon solid acid was successfully prepared by one-step hydrothermal carbonization. • The acrylic acid as monomer was effectively reduce the diameter size of particle. • The solid acid catalyst show good catalytic performance of starch hydrolysis. • The solid acid catalyst is not significantly deteriorated after repeated use

  15. Modelling of tomato stem diameter growth rate based on physiological responses

    International Nuclear Information System (INIS)

    Li, L.; Tan, J.; Lv, T.

    2017-01-01

    The stem diameter is an important parameter describing the growth of tomato plant during vegetative growth stage. A stem diameter growth model was developed to predict the response of plant growth under different conditions. By analyzing the diurnal variations of stem diameter in tomato (Solanum lycopersicum L.), it was found that the stem diameter measured at 3:00 am was the representative value as the daily basis of tomato stem diameter. Based on the responses of growth rate in stem diameter to light and temperature, a linear regression relationship was applied to establish the stem diameter growth rate prediction model for the vegetative growth stage in tomato and which was further validated by experiment. The root mean square error (RMSE) and relative error (RE) were used to test the correlation between measured and modeled stem diameter variations. Results showed that the model can be used in prediction for stem diameter growth rate at vegetative growth stage in tomato. (author)

  16. Fragmentation of Solid Materials Using Shock Tubes. Part 1: First Test Series in a Small Diameter Shock Tube

    Science.gov (United States)

    2017-01-01

    major issues. Table 7. Issues faced in curve fitting experimental fragment size distributions. Issue Discussion Solution 1. Independent...results in overpopulated small bins and underpopulated large bins, both of which adversely impact fit quality. Away from the extremes, choose bin...implement the solutions given in Table 7. Unfortunately, because of the difficulty of optimizing across two variables using MS Excel macros, these

  17. Fragmentation of Solid Materials Using Shock Tubes. Part 2: First Test Series in a Large Diameter Shock Tube

    Science.gov (United States)

    2017-12-01

    SUPPLEMENTARY NOTES 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...in 81.4 (*) 13,500 Mounted in the center of a thick steel plate. 18 Fully Tempered Glass Window 4-ft x 6-ft x ¼-in 81.4 (*) 13,500 Mounted in the...center of a thick steel plate. 19 Fully Tempered Glass Window 4-ft x 6-ft x ¼-in 81.4 (*) 13,500 Mounted in the center of a thick steel plate. 20

  18. Modular Small Diameter Vascular Grafts with Bioactive Functionalities

    Science.gov (United States)

    Neufurth, Meik; Wang, Xiaohong; Tolba, Emad; Dorweiler, Bernhard; Schröder, Heinz C.; Link, Thorben; Diehl-Seifert, Bärbel; Müller, Werner E. G.

    2015-01-01

    We report the fabrication of a novel type of artificial small diameter blood vessels, termed biomimetic tissue-engineered blood vessels (bTEBV), with a modular composition. They are composed of a hydrogel scaffold consisting of two negatively charged natural polymers, alginate and a modified chitosan, N,O-carboxymethyl chitosan (N,O-CMC). Into this biologically inert scaffold two biofunctionally active biopolymers are embedded, inorganic polyphosphate (polyP) and silica, as well as gelatin which exposes the cell recognition signal, Arg-Gly-Asp (RGD). These materials can be hardened by exposure to Ca2+ through formation of Ca2+ bridges between the polyanions, alginate, N,O-CMC, and polyP (alginate-Ca2+-N,O-CMC-polyP). The bTEBV are formed by pressing the hydrogel through an extruder into a hardening solution, containing Ca2+. In this universal scaffold of the bTEBV biomaterial, polycations such as poly(l-Lys), poly(d-Lys) or a His/Gly-tagged RGD peptide (three RGD units) were incorporated, which promote the adhesion of endothelial cells to the vessel surface. The mechanical properties of the biopolymer material (alginate-Ca2+-N,O-CMC-polyP-silica) revealed a hardness (elastic modulus) of 475 kPa even after a short incubation period in CaCl2 solution. The material of the artificial vascular grafts (bTEBVs with an outer size 6 mm and 1.8 mm, and an inner diameter 4 mm and 0.8 mm, respectively) turned out to be durable in 4-week pulsatile flow experiments at an alternating pressure between 25 and 100 mbar (18.7 and 75.0 mm Hg). The burst pressure of the larger (smaller) vessels was 850 mbar (145 mbar). Incorporation of polycationic poly(l-Lys), poly(d-Lys), and especially the His/Gly-tagged RGD peptide, markedly increased the adhesion of human, umbilical vein/vascular endothelial cells, EA.HY926 cells, to the surface of the hydrogel. No significant effect of the polyP samples on the clotting of human plasma is measured. We propose that the metabolically degradable

  19. Solid polymer electrolyte composite membrane comprising laser micromachined porous support

    Science.gov (United States)

    Liu, Han [Waltham, MA; LaConti, Anthony B [Lynnfield, MA; Mittelsteadt, Cortney K [Natick, MA; McCallum, Thomas J [Ashland, MA

    2011-01-11

    A solid polymer electrolyte composite membrane and method of manufacturing the same. According to one embodiment, the composite membrane comprises a rigid, non-electrically-conducting support, the support preferably being a sheet of polyimide having a thickness of about 7.5 to 15 microns. The support has a plurality of cylindrical pores extending perpendicularly between opposing top and bottom surfaces of the support. The pores, which preferably have a diameter of about 5 microns, are made by laser micromachining and preferably are arranged in a defined pattern, for example, with fewer pores located in areas of high membrane stress and more pores located in areas of low membrane stress. The pores are filled with a first solid polymer electrolyte, such as a perfluorosulfonic acid (PFSA) polymer. A second solid polymer electrolyte, which may be the same as or different than the first solid polymer electrolyte, may be deposited over the top and/or bottom of the first solid polymer electrolyte.

  20. Solid state phenomena

    CERN Document Server

    Lawrance, R

    1972-01-01

    Solid State Phenomena explores the fundamentals of the structure and their influence on the properties of solids. This book is composed of five chapters that focus on the electrical and thermal conductivities of crystalline solids. Chapter 1 describes the nature of solids, particularly metals and crystalline materials. This chapter also presents a model to evaluate crystal structure, the forces between atom pairs, and the mechanism of plastic and elastic deformation. Chapter 2 demonstrates random vibrations of atoms in a solid using a one-dimensional array, while Chapter 3 examines the resista

  1. Design of supporting devices for thin pipes of large diameter

    International Nuclear Information System (INIS)

    Marsault, J.J.; Dornez, R.

    1981-01-01

    When an analysis is made in accordance with ASME Code Class 1 for piping by the stress indices method (NB 3650), the stresses induced locally in the piping by the supports are not taken into account. For piping whose thickness is small in relation to its diameter, which is subject to sudden temperature changes, to seismic shocks and which also operates at high temperature, it is no longer possible to ignore these effects. This is the case with piping of the sodium circuits of fast breeder reactors for which, after performance of mechanical analyses by the Zick method and thermo-mechanical analyses on the support collars of the classic type, with all the uncertainties involved in reckoning the real forces of contact, a design was finally decided upon which corresponds to the double imperative of permitting free radial expansion of the piping while withstanding considerable loads with a minimum of local deformations in the piping. The device adopted consists of a rigid collar connected to the piping by blades which are flexible radially in relation to the pipe and rigid tangentially. These blades are attached to very short ring lugs welded on to the piping. (orig./GL)

  2. Sieving experiments and pore diameter: it's not a simple relationship.

    Science.gov (United States)

    Krauss, Daniel; Gillespie, Dirk

    2010-10-01

    The classic sieving experiment for estimating an ion channel's diameter with successively larger ions is re-examined. Using a very reduced model of a calcium channel, it is shown that sieving experiments measure a combination of three mechanisms: the cross-sectional area available to the sieving ions (the classic interpretation), the exclusion of the sieving ions from a pore crowded with amino acid side chains that protrude into the permeation pathway, and competitive selectivity of the sieving ions with other ions in the bath (even if those are present only at trace concentrations). The latter two can be called sieving-by-crowding because they stem from the excluded volume of the amino acids in the permeation pathway. The model shows that--to a first--order approximation-sieving experiments measure the available volume inside a selectivity filter, rather than the available cross-sectional area. The two are only the same if the narrow part of the pore does not have flexible amino acid side chains interacting directly with the permeant ions; this may be true of potassium channels, but not calcium, sodium, and other channels with "crowded" selectivity filters.

  3. Through pore diameter in the cell wall of Chara corallina.

    Science.gov (United States)

    Berestovsky, G N; Ternovsky, V I; Kataev, A A

    2001-06-01

    Determination of pore size of the cell wall of Chara corallina has been made by using the polyethylene glycol (PEG) series as the hydrophilic probing molecules. In these experiments, the polydispersity of commercial preparation of PEGs was allowed for. The mass share (gamma(p)) of polyethylene glycol preparation fractions penetrating through the pores was determined using a cellular 'ghost', i.e. fragments of internodal cell walls filled with a 25% solution of non-penetrating PEG 6000 and tied up at the ends. In water, such a 'ghost' developed a hydrostatic pressure close to the cell turgor which persisted for several days. The determination of gamma(p), for polydisperse polyethylene glycols with different average molecular mass (M) was calculated from the degree of pressure restoration after water was replaced by a 5-10% polymer solution. Pressure was recorded using a dynamometer, which measures, in the quasi-isometric mode, the force necessary for the partial compression of the 'ghost' in its small fragment. By utilizing the data on the distribution of PEG 1000, 1450, 2000, and 3350 fractions over molecular mass (M), it was found that gamma(p), for these polyethylene glycols corresponded to the upper limit of ML=800-1100 D (hydrodynamic radius of molecules, r(h)=0.85-1.05 nm). Thus, the effective diameter of the pores in the cell wall of Chara did not exceed 2.1 nm.

  4. First phase of small diameter heater experiments in tuff

    International Nuclear Information System (INIS)

    Zimmerman, R.M.

    1983-01-01

    As part of the Nevada Nuclear Waste Storage Investigations (NNWSI) project, we have undertaken small diameter heater experiments in the G-Tunnel Underground Facility on the Nevada Test Site (NTS). These experiments are to evaluate the thermal and hydrothermal behavior which might be encountered if heat producing nuclear waste were disposed of in welded and nonwelded tuffs. The two Phase I experiments discussed have focused on vertical borehole emplacements. In each experiment, temperatures were measured along the surface of the 10.2-cm-dia heater and the 12.7-cm-dia boreholes. For each experiment, measurements were compared with computer model representations. Maximum temperatures reached were: 196 0 C for the welded tuff after 21 days of operations at 800W and 173 0 C for the nonwelded tuff after 35 days of operations at 500W. Computed results indicate that the same heat transfer model (includes conduction and radiation only) can describe the behavior of both tuffs using empirical techniques to describe pore water vaporization. Hydrothermal measurements revealed heat-indiced water migration. Results indicated that small amounts of liquid water migrated into the welded tuff borehole early in the heating period. Once the rock-wall temperatures exceeded 94 0 C, in both tuffs, there was mass transport of water vapor as evidence indicated condensation cooler regions. Borehole pressures remained essentially ambient during the thermal periods

  5. Small-Diameter PTFE Portosystemic Shunts: Portocaval vs Mesocaval

    Directory of Open Access Journals (Sweden)

    Robert Shields

    1998-01-01

    Full Text Available Fifty-seven patients with failed sclerotherapy received a mesocaval interposition shunt with an externally supported, ringed polytetrafluoroethylene prosthesis of either 10 or 12 mm diameter. Thirty-one patients had Child-Pugh gradeA disease and 26 grade B; all had a liver volume of 1000– 2500 ml. Follow-up ranged from 16 months to 6 years 3 months. Three patients (5 per cent died in the postoperative period. There were two postoperative recurrences of variceal haemorrhage and one recurrent bleed in the second year after surgery. The cumulative shunt patency rate was 95 per cent and the incidence of encephalopathy 9 per cent; the latter was successfully managed by protein restriction and/or lactulose therapy. The actuarial survival rate for the whole group at 6 years was 78 per cent, for those with Child-Pugh grade A 88 per cent and for grade B 67 per cent. Small-lumen mesocaval interposition shunting achieves portal decompression, preserves hepatopetal flow, has a low incidence of shunt thrombosis, prevents recurrent variceal bleeding and is not associated with significant postoperative encephalopathy.

  6. Patch diameter limits for tiered subaperture SAR image formation algorithms

    Science.gov (United States)

    Doerry, Armin W.

    1995-06-01

    Synthetic aperture radar image formation algorithms typically use transform techniques that often require trading between image resolution, algorithm efficiency, and focused image scene size limits. This is due to assumptions for the data such as simplified (often straight-line) flight paths, simplified imaging geometry, and simplified models for phase functions. Many errors in such assumptions are typically untreatable due to their dependance on both data domain positions and image domain positions. The result is that large scenes often require inefficient multiple image formation iterations, followed by a mosaicking operation of the focused image patches. One class of image formation algorithms that perform favorably divides the spatial and frequency apertures into subapertures, and perhaps those subapertures into sub- subapertures, and so on, in a tiered subaperture fashion. This allows a gradual shift from data domain into image domain that allows correcting many types of errors that limit other image formation algorithms, even in a dynamic motion environment, thereby allowing large focused image patches without mosaicking. This paper presents and compared focused patch diameter limits for tiered subaperture image formation algorithms, for various numbers of tiers of subapertures. Examples are given that show orders-of-magnitude improvement in non- mosaicked focused image patch size over traditional polar format processing, and that patch size limits increase with the number of tiers of subapertures, although with diminishing returns.

  7. A 24mm diameter fibre positioner for spectroscopic surveys

    Science.gov (United States)

    Hörler, Philipp; Kronig, Luzius; Kneib, Jean-Paul; Bleuler, Hannes; Bouri, Mohamed

    2016-07-01

    One of the big research topics in modern cosmology is the mystery of dark Energy. To unveil the secret, cosmologists want to measure precisely the evolution of large scale structures in the universe. One way of doing so is to measure the 3D location of a high number of galaxies. By measuring the redshift of a galaxy, it is possible to find its distance. In order to measure a high number of galaxies in a practical amount of time, we need to observe multiple objects in parallel. Instead of a spectrograph, thousands of optical fibres are placed in the focal plane of a telescope. They will transmit the light of many objects to a spectrograph. Each fibre has to be positioned to several μm precision in the focal plane of a telescope for each exposure. Each fibre is positioned by a 2-axis fibre positioner. In this paper such a fibre positioner with 24-mm diameter is presented. It is driven by two brushless DC motors in combination with a backlash free gearbox. The positioner has an optimal central fibre path and improved angular alignment. The fibre runs through the centre of the positioner and is only bent at the top to reach its target position. In this way, the flexion and torsion of the fibre are minimal. In addition to the high positioning accuracy, the design is optimized to allow a minimal tilt error of the fibre. This is demonstrated using a novel optical tilt measurement system.

  8. Continuous Measurement of Particle Hygroscopicity as a Function of Diameter

    Science.gov (United States)

    Brock, C. A.; Anderson, B. E.; Ziemba, L. D.; Thornhill, K. L.; Moore, R.; Beyersdorf, A. J.; Winstead, E. L.; Crumeyrolle, S.; Wagner, N.; Langridge, J. M.; Richardson, M.; Lack, D. A.; Law, D. C.; Shingler, T.; Sorooshian, A.

    2012-12-01

    An ultra-high sensitivity aerosol spectrometer (UHSAS, Droplet Measurement Technologies, Boulder, CO, USA) has been substantially modified to humidify the aerosol sample stream. The size distribution of deliquesced particles at humidities as high as 95% is measured. By combining a Mie model of instrument response with measurements of dry and wet size distributions, the hygroscopic growth factor as a function of particle diameter can be estimated. By operating a second, well-calibrated dry UHSAS simultaneously with the humidified UHSAS, the size-dependent particle hygroscopicity can be determined continuously, which is particularly useful for airborne sampling where rapid time response is required. The technique has been applied to laboratory particles of inorganic salts and of polystyrene latex, and to mixed sulfate/organic particles and dense forest fire smoke measured on an aircraft during the Deep Convective Clouds and Chemistry (DC3) project. Results will be compared with measurements of aerosol extinction at different RH values and of hygroscopic growth made with a differential aerosol sizing and hygroscopicity spectrometer probe (DASH-SP). Initial evaluations of changes in hygroscopicity due to processing in convective clouds will be presented. Limitations of the technique, such as the effects of external mixtures and insoluble components, will be discussed.

  9. Magnetorheology of submicron diameter iron microwires dispersed in silicone oil

    International Nuclear Information System (INIS)

    Bell, R C; Karli, J O; Vavreck, A N; Zimmerman, D T; Ngatu, G T; Wereley, N M

    2008-01-01

    We investigate the magnetorheological (MR) properties of suspensions containing iron microwires with 260 nm diameter and two distinct length distributions of 5.4 ± 5.2 µm and 7.6 ± 5.1 µm suspended in silicone oil (0.45 Pa s). The rheological properties of these fluids were determined using a parallel plate rheometer equipped with a variable strength electromagnet. The shear stress was measured as a function of shear rate for increasing applied magnetic fields. These results were modeled using the Bingham-plastic constitutive model to determine the apparent yield stress and viscosity as a function of increasing volume fraction and length of microwires. At a saturated magnetic flux density, the yield stress using the 5.4 µm microwires was found to be 0.65, 2.23, and 4.76 kPa for the 2, 4, and 6 vol% suspensions, respectively. For the 7.6 µm wires, the yield stress increases to 8.2 kPa for the 6 vol% suspension. Compared with conventional MR fluids employing spherical particles, the degree of settling is markedly decreased in the microwire-based fluids. At 6 vol%, conventional fluids display appreciable settling whereas the microwire-based fluids display no discernable settling. Moreover, the rod-shaped microwires are shown to increase the yield stress of the fluids and enhance the MR performance

  10. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    The development of offshore wind turbines has been in rapid growth since the construction of the first offshore wind farm in 1991 at Vindeby, Denmark. Developing from 11 turbines at a water depth of 2-6 m each with a capacity of 450 kW to the latest farms with up to 175 turbines each with a capac......The development of offshore wind turbines has been in rapid growth since the construction of the first offshore wind farm in 1991 at Vindeby, Denmark. Developing from 11 turbines at a water depth of 2-6 m each with a capacity of 450 kW to the latest farms with up to 175 turbines each...... with a capacity of 3.6 MW and placed at water depths beyond 25 m. Different foundation solutions have over the years been applied for offshore turbines, but monopiles are currently the most applied foundation type and are typically with a pile diameter of 4-6 m and applied up to a water depth of 25 m....... The expected development of offshore wind farms is towards larger farms, larger turbines and larger water depths. Monopiles have been applied widely and it is of interest to investigate the possibilities to further optimize the design and in particular the modelling of the soil-structure interaction...

  11. Multi-diameter silicon nanowires: Fabrication, characterization, and modeling

    Science.gov (United States)

    Alagoz, Arif Sinan

    Nanotechnology is a rapidly expanding interdisciplinary field offering novel devices for broad range of applications. Quantum effects and surface to volume ratio of nanostructures are strongly size dependent, and redefine material properties at nanoscale. Silicon is one of the most promising materials for next generation nanostructured transistors, photonics devices, Li-ion batteries, photovoltaic solar cells, and thermoelectric energy generators. Since electrical, optical, and mechanical properties of nanostructures strongly depend on their shape, size, periodicity, and crystal structure; it is crucial to control these parameters in order to optimize device performance for targeted applications. This dissertation is intended to develop a low-cost, low-temperature, high-throughput, and large-area nanowire fabrication method that can produce well-ordered arrays of hierarchical single-crystal silicon nanowires at large scale by using nanosphere lithography and metal-assisted chemical etching. Nanowire morphology was characterized by using scanning electron microscope and optical properties of nanowire arrays were modeled with the help of finite-difference-time domain method. These novel multi-diameter silicon nanowire arrays have the potential applications in many fields including but not limited to next generation nanowire solar cells to field ionization gas sensors.

  12. Auxin and ethylene regulation of diameter growth in trees.

    Science.gov (United States)

    Savidge, R A

    1988-12-01

    Recent studies on the phytohormonal regulation of seasonal cell-division activity in the cambium, primary-wall radial expansion of cambial derivatives, differentiation of xylem cells, and growth of the cortex in forest trees of the north temperate zone are reviewed. Indol-3-ylacetic acid (IAA, auxin) has been characterized by combined gas chromatography-mass spectrometry (GC-MS) in the cambial region of Abies balsamea, Pinus densiflora, Pinus sylvestris and Quercus robur. All of the evidence supports the hypothesis that developing leaves and extending shoots are primary sources of IAA. The rate of ethylene emanation varies among conifer species when adjoining phloem and cambial tissues are incubated in vitro. The cambium from young cuttings of Abies balsamea produces more ethylene than that from older cuttings. Ethylene production by seven-year-old Abies balsamea cambium is substantially increased in vitro when the tissue is provided with exogenous 1-aminocyclopropane-1-carboxylic acid and IAA. In response to elevated ethylene concentrations, cortex growth is accelerated in both hardwood and conifer seedlings. Ethrel (2-chloroethylphosphonic acid) increases ray size and ray-cell number and promotes traumatic resin-canal development in xylem. In Ulmus americana, endogenous ethylene concentrations are inversely correlated with cambial activity. Ethylene decreases vessel diameter in Acer negundo, Acer platanoides and Ulmus americana. Several studies suggest that ethylene has a role in regulating reaction-wood formation in both conifers and hardwoods.

  13. Solid Base Catalysis

    CERN Document Server

    Ono, Yoshio

    2011-01-01

    The importance of solid base catalysts has come to be recognized for their environmentally benign qualities, and much significant progress has been made over the past two decades in catalytic materials and solid base-catalyzed reactions. The book is focused on the solid base. Because of the advantages over liquid bases, the use of solid base catalysts in organic synthesis is expanding. Solid bases are easier to dispose than liquid bases, separation and recovery of products, catalysts and solvents are less difficult, and they are non-corrosive. Furthermore, base-catalyzed reactions can be performed without using solvents and even in the gas phase, opening up more possibilities for discovering novel reaction systems. Using numerous examples, the present volume describes the remarkable role solid base catalysis can play, given the ever increasing worldwide importance of "green" chemistry. The reader will obtain an overall view of solid base catalysis and gain insight into the versatility of the reactions to whic...

  14. Comparison of CT-Determined Pulmonary Artery Diameter, Aortic Diameter, and Their Ratio in Healthy and Diverse Clinical Conditions.

    Directory of Open Access Journals (Sweden)

    Sang Hoon Lee

    Full Text Available The main pulmonary artery diameter (mPA, aortic diameter (Ao, and the mPA/Ao ratio, easily measured using chest computed tomography (CT, provide information that enables the diagnosis and evaluation of cardiopulmonary diseases. Here, we used CT to determine the sex- and age-specific distribution of normal reference values for mPA, Ao, and mPA/Ao ratio in an adult Korean population.Data from non-contrast, ECG-gated, coronary-calcium-scoring CT images of 2,547 individuals who visited the Health Screening Center of the Severance Hospital were analyzed. Healthy individuals (n = 813 included those who do not have hypertension, diabetes, asthma, obstructive lung disease, ischemic heart disease, stroke, smoking, obesity, and abnormal CT findings. Both mPA and Ao were measured at the level of bifurcation of the main pulmonary artery.The mean mPA and Ao were 25.9 mm and 30.0 mm in healthy participants, respectively, while the mean mPA/Ao ratio was 0.87. Medical conditions associated with a larger mPA were male, obesity, smoking history, hypertension, and diabetes. A larger mPA/Ao ratio was associated with female, the obese, non-smoker, normotensive, and normal serum level of lipids, while a smaller mPA/Ao ratio was associated with older age. In healthy individuals, the 90th percentile sex-specific mPA, Ao, and mPA/Ao ratio were, 31.3 mm (95% CI 29.9-32.2, 36.8 mm (95% CI 35.7-37.5, and 1.05 (95% CI 0.99-1.07 in males, and 29.6 mm (95% CI 29.1-30.2, 34.5 mm (95% CI 34.1-34.9, and 1.03 (95% CI 1.02-1.06 in females, respectively.In the Korean population, the mean mPA reference values in male and female were 26.5 mm and 25.8 mm, respectively, while the mean mPA/Ao ratio was 0.87. These values were influenced by a variety of underlying medical conditions.

  15. Silicon doped boron carbide nanorod growth via a solid-liquid-solid process

    Science.gov (United States)

    Han, Wei-Qiang

    2006-03-01

    Here we report the synthesis of silicon doped boron carbide (Si-doped B4C) nanorods via a solid reaction using activated carbon, boron, and silicon powder as reactants. These nanorods have been studied by high-resolution transmission electron microscopy, scanning electron microscopy, electron energy loss spectroscopy, and energy-dispersive x-ray spectrometry. The diameter of Si-doped B4C nanorods ranges from 15to70nm. The length of Si-doped B4C nanorods is up to 30μm. NixCoyBz nanoparticles are used as catalysts for the growth of Si-doped B4C nanorods. A solid-liquid-solid growth mechanism is proposed.

  16. Bark thickness related to tree diameter in sugar maple (Acer saccharum Marsh.)

    Science.gov (United States)

    H. Clay Smith

    1969-01-01

    Bark thickness for sugar maple trees in Vermont was found to be related to tree diameter at breast height (d.b.h.). The relationship was positive-as the diameter increased, the bark thickness increased.

  17. Anatomic radiological study of transverse diameter of abdominal aorta by computerized tomography

    International Nuclear Information System (INIS)

    Ures, S.

    1984-01-01

    The transverse diameter of abdominal aorta by computerized tomography is studied. The purpose is establish the frequent standard diameters and then diagnose early pathologies, mainly aneurisms. (M.A.C.) [pt

  18. Bloch-Wave Engineered Submicron Diameter Micropillars with Quality Factors Exceeding 10,000

    DEFF Research Database (Denmark)

    Hofling, S.; Lermer, M.; Gregersen, Niels

    2011-01-01

    Adiabatic design submicron diameter quantum-dot micropillars have been designed and implemented for cavity quantum electrodynamics experiments. Ultra-high experimental quality factors (>10,000) are obtained for submicron diameters and strong light-matter interaction is observed.......Adiabatic design submicron diameter quantum-dot micropillars have been designed and implemented for cavity quantum electrodynamics experiments. Ultra-high experimental quality factors (>10,000) are obtained for submicron diameters and strong light-matter interaction is observed....

  19. Predicting past and future diameter growth for trees in the northeastern United States

    Science.gov (United States)

    James A. Westfall

    2006-01-01

    Tree diameter growth models are widely used in forestry applications, often to predict tree size at a future point in time. Also, there are instances where projections of past diameters are needed. A relative diameter growth model was developed to allow prediction of both future and past growth rates. Coefficients were estimated for 15 species groups that cover most...

  20. Mixed-effects height–diameter models for ten conifers in the inland ...

    African Journals Online (AJOL)

    To demonstrate the utility of mixed-effects height–diameter models when conducting forest inventories, mixedeffects height–diameter models are presented for several commercially and ecologically important conifers in the inland Northwest of the USA. After obtaining height–diameter measurements from a plot/stand of ...

  1. 78 FR 60897 - Certain Welded Large Diameter Line Pipe From Japan

    Science.gov (United States)

    2013-10-02

    ... COMMISSION Certain Welded Large Diameter Line Pipe From Japan Determination On the basis of the record \\1... the antidumping duty order on certain welded large diameter line pipe from Japan would likely to lead... Certain Welded Large Diameter Line Pipe from Japan: Investigation No. 731-TA-919 (Second Review). By order...

  2. Periodic Annual Diameter Increment After Overstory Removal in Mixed Conifer Stands

    Science.gov (United States)

    Fabian C.C. Uzoh; K. Leroy Dolph; John R. Anstead

    1998-01-01

    Diameter growth rates of understory trees were measured for periods both before and after overstory removal on six study areas in northern California. All the species responded with increased diameter growth after adjusting to their new environments. Linear regression equations that predict periodic annual increment of the diameters of the residual trees after...

  3. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep

  4. Movement mechanisms of gross solids in intermittent flow.

    Science.gov (United States)

    Littlewood, K; Butler, D

    2003-01-01

    Gross solids, such as used tampons, sanitary towels and faecal stools, are introduced into the sewer network via the WC. Although small diameter pipes (< or = 150mm diameter) make up a large proportion of most sewer networks, the transport behaviour of gross solids in these smaller pipes is not fully established. In particular, there are concerns about the effect of water conservation measures on the transport of gross solids in the intermittent flow regime prevalent in small pipes. This paper introduces a study carried out on the movement of solids in this flow regime. An extensive series of experiments has been carried out to investigate the movement mechanisms and behaviour in detail. It was found that there are three different mechanisms of movement, and photographic evidence is provided in the paper. The concept and implications of the "limiting solid transport distance" is also introduced. It is argued that solid movement is dependent on factors other than just WC flush volume and that increased blockage potential is not inevitable.

  5. Detection and quantification of the solid component in pulmonary subsolid nodules by semiautomatic segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, Ernst T. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Kennemer Gasthuis, Department of Radiology, Haarlem (Netherlands); Jacobs, Colin; Riel, Sarah van [Radboud University Medical Center, Diagnostic Image Analysis Group, Nijmegen (Netherlands); Ginneken, Bram van [Radboud University Medical Center, Diagnostic Image Analysis Group, Nijmegen (Netherlands); Fraunhofer MEVIS, Bremen (Germany); Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Koning, Harry J. de [Erasmus Medical Center, Department of Public Health, Rotterdam (Netherlands); Horeweg, Nanda [Erasmus Medical Center, Department of Public Health, Rotterdam (Netherlands); Erasmus Medical Center, Department of Pulmonology, Rotterdam (Netherlands); Prokop, Mathias [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands); Gietema, Hester A.; Mali, Willem P.T.M.; Jong, Pim A. de [University Medical Center, Department of Radiology, Utrecht (Netherlands)

    2014-10-07

    To determine whether semiautomatic volumetric software can differentiate part-solid from nonsolid pulmonary nodules and aid quantification of the solid component. As per reference standard, 115 nodules were differentiated into nonsolid and part-solid by two radiologists; disagreements were adjudicated by a third radiologist. The diameters of solid components were measured manually. Semiautomatic volumetric measurements were used to identify and quantify a possible solid component, using different Hounsfield unit (HU) thresholds. The measurements were compared with the reference standard and manual measurements. The reference standard detected a solid component in 86 nodules. Diagnosis of a solid component by semiautomatic software depended on the threshold chosen. A threshold of -300 HU resulted in the detection of a solid component in 75 nodules with good sensitivity (90 %) and specificity (88 %). At a threshold of -130 HU, semiautomatic measurements of the diameter of the solid component (mean 2.4 mm, SD 2.7 mm) were comparable to manual measurements at the mediastinal window setting (mean 2.3 mm, SD 2.5 mm [p = 0.63]). Semiautomatic segmentation of subsolid nodules could diagnose part-solid nodules and quantify the solid component similar to human observers. Performance depends on the attenuation segmentation thresholds. This method may prove useful in managing subsolid nodules. (orig.)

  6. Solid state video cameras

    CERN Document Server

    Cristol, Y

    2013-01-01

    Solid State Video Cameras reviews the state of the art in the field of solid-state television cameras as compiled from patent literature. Organized into 10 chapters, the book begins with the basic array types of solid-state imagers and appropriate read-out circuits and methods. Documents relating to improvement of picture quality, such as spurious signal suppression, uniformity correction, or resolution enhancement, are also cited. The last part considerssolid-state color cameras.

  7. Nanoscale hydrodynamics near solids

    Science.gov (United States)

    Camargo, Diego; de la Torre, J. A.; Duque-Zumajo, D.; Español, Pep; Delgado-Buscalioni, Rafael; Chejne, Farid

    2018-02-01

    Density Functional Theory (DFT) is a successful and well-established theory for the study of the structure of simple and complex fluids at equilibrium. The theory has been generalized to dynamical situations when the underlying dynamics is diffusive as in, for example, colloidal systems. However, there is no such a clear foundation for Dynamic DFT (DDFT) for the case of simple fluids in contact with solid walls. In this work, we derive DDFT for simple fluids by including not only the mass density field but also the momentum density field of the fluid. The standard projection operator method based on the Kawasaki-Gunton operator is used for deriving the equations for the average value of these fields. The solid is described as featureless under the assumption that all the internal degrees of freedom of the solid relax much faster than those of the fluid (solid elasticity is irrelevant). The fluid moves according to a set of non-local hydrodynamic equations that include explicitly the forces due to the solid. These forces are of two types, reversible forces emerging from the free energy density functional, and accounting for impenetrability of the solid, and irreversible forces that involve the velocity of both the fluid and the solid. These forces are localized in the vicinity of the solid surface. The resulting hydrodynamic equations should allow one to study dynamical regimes of simple fluids in contact with solid objects in isothermal situations.

  8. Multivalent ion conducting solids

    Energy Technology Data Exchange (ETDEWEB)

    Imanaka, N. [Osaka Univ., Suita, Osaka (Japan). Dept. of Applied Chemistry

    2008-07-01

    Solid electrolytes possess important characteristics for industrial applications. Only a single ionic species can macroscopically migrate in these solids. This paper described a the new NASICON (M-Zr-Nb-P-O) type system, exhibiting an exceptionally high level of trivalent M3+ ion conductivity on polycrystalline solids. The partial substitution of the smaller higher valent Nb5+ ion for Zr4+ stabilized the NASICON phase and realized the M3+ ion conduction in the NASICON structure. It was concluded that the conductivities of the series are comparable to those of the practically applied solid electrolytes of oxide anion conductors of YSZ and CSZ. 3 refs., 2 figs.

  9. Management of solid waste

    International Nuclear Information System (INIS)

    Thompson, W.T.; Stinton, L.H.

    1980-01-01

    Compliance with the latest regulatory requirements addressing disposal of radioactive, hazardous, and sanitary solid waste requires the application of numerous qualitative and quantitative criteria in the selection, design, and operation of solid waste management facilities. Due to the state of flux of these regulatory requirements from EPA and NRC several waste management options were identified as being applicable to the management of the various types of solid waste. This paper highlights the current regulatory constraints and the design and operational requirements for construction of both storage and disposal facilities for use in management of DOE-ORO solid waste. Capital and operational costs are included for both disposal and storage options

  10. Understanding solid state physics

    CERN Document Server

    Holgate, Sharon Ann

    2009-01-01

    Where Sharon Ann Holgate has succeeded in this book is in packing it with examples of the application of solid state physics to technology. … All the basic elements of solid state physics are covered … . The range of materials is good, including as it does polymers and glasses as well as crystalline solids. In general, the style makes for easy reading. … Overall this book succeeds in showing the relevance of solid state physics to the modern world … .-Contemporary Physics, Vol. 52, No. 2, 2011I was indeed amused and inspired by the wonderful images throughout the book, carefully selected by th

  11. Parameters Affecting the Erosive Burning of Solid Rocket Motor

    Directory of Open Access Journals (Sweden)

    Abdelaziz Almostafa

    2018-01-01

    Full Text Available Increasing the velocity of gases inside solid rocket motors with low port-to-throat area ratios, leading to increased occurrence and severity of burning rate augmentation due to flow of propellant products across burning propellant surfaces (erosive burning, erosive burning of high energy composite propellant was investigated to supply rocket motor design criteria and to supplement knowledge of combustion phenomena, pressure, burning rate and high velocity of gases all of these are parameters affect on erosive burning. Investigate the phenomena of the erosive burning by using the 2’inch rocket motor and modified one. Different tests applied to fulfil all the parameters that calculated out from the experiments and by studying the pressure time curve and erosive burning phenomena.

  12. Filmwise condensation on low integral-fin tubes of different diameter

    OpenAIRE

    Van Petten, Thomas Louis

    1988-01-01

    Heat transfer measurements were made for filmwise condensation of R-113, steam and ethylene glycol on three sets of finned tubes which differed only in root diameter. The fin root diameters were 12.7 mm. 19.05 mm and 25.0 mm. A comparison of the enhancement ratios (based on constant vapor-side temperature drop) revealed that, within the range of diameter tested, the effect of root diameter was small. Results indicated that two or more trends may exist while increasing root diameter. With the ...

  13. Study of the equivalent diameter concept for heat transfer by forced convection in annular channels

    International Nuclear Information System (INIS)

    Mendez T, D.

    1994-01-01

    This work describes a comparative analysis between experimental values of heat transfer coefficients in fully developed turbulent flow for a concentric annular channel, and those calculated with the empirical correlations obtained for tubes by Dittus-Boelter, Sieder and Tate, a modified Colburn equation, and that proposed by Gnielinski which applies the analogy between friction and heat transfer. The coefficients were calculated by means of two different equivalent diameters: 1) The hydraulic equivalent diameter; and 2) The heated equivalent diameter. It was concluded that the hydraulic equivalent diameter gives much better results than the heated equivalent diameter. (Author)

  14. RESULTS OF PHYSICOCHEMICAL CHARACTERIZATION AND CAUSTIC DISSOLUTION TESTS ON TANK 241-C-108 HEEL SOLIDS

    Energy Technology Data Exchange (ETDEWEB)

    CALLAWAY WS; HUBER HJ

    2010-07-01

    Based on an ENRAF waste surface measurement taken February 1, 2009, double-shell tank (DST) 241-AN-106 (AN-106) contained approximately 278.98 inches (793 kgal) of waste. A zip cord measurement from the tank on February 1, 2009, indicated a settled solids layer of 91.7 inches in height (280 kgal). The supernatant layer in February 2009, by difference, was approximately 187 inches deep (514 kgal). Laboratory results from AN-106 February 1, 2009 (see Table 2) grab samples indicated the supernatant was below the chemistry limit that applied at the time as identified in HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control (AC) 5.16, 'Corrosion Mitigation Controls.' (The limits have since been removed from the Technical Safety Requirements (TSR) and are captured in OSD-T-151-00007, Operating Specifications for the Double-Shell Storage Tanks.) Problem evaluation request WRPS-PER-2009-0218 was submitted February 9, 2009, to document the finding that the supernatant chemistry for grab samples taken from the middle and upper regions of the supernatant was noncompliant with the chemistry control limits. The lab results for the samples taken from the bottom region of the supernatant met AC 5.16 limits.

  15. Results Of Physicochemical Characterization And Caustic Dissolution Tests On Tank 241-C-108 Heel Solids

    International Nuclear Information System (INIS)

    Callaway, W.S.; Huber, H.J.

    2010-01-01

    Based on an ENRAF waste surface measurement taken February 1, 2009, double-shell tank (DST) 241-AN-106 (AN-106) contained approximately 278.98 inches (793 kgal) of waste. A zip cord measurement from the tank on February 1, 2009, indicated a settled solids layer of 91.7 inches in height (280 kgal). The supernatant layer in February 2009, by difference, was approximately 187 inches deep (514 kgal). Laboratory results from AN-106 February 1, 2009 (see Table 2) grab samples indicated the supernatant was below the chemistry limit that applied at the time as identified in HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control (AC) 5.16, 'Corrosion Mitigation Controls.' (The limits have since been removed from the Technical Safety Requirements (TSR) and are captured in OSD-T-151-00007, Operating Specifications for the Double-Shell Storage Tanks.) Problem evaluation request WRPS-PER-2009-0218 was submitted February 9, 2009, to document the finding that the supernatant chemistry for grab samples taken from the middle and upper regions of the supernatant was noncompliant with the chemistry control limits. The lab results for the samples taken from the bottom region of the supernatant met AC 5.16 limits.

  16. Radiation Characterization Summary: ACRR Central Cavity Free-Field Environment with the 32-Inch Pedestal at the Core Centerline (ACRR-FF-CC-32-cl).

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Richard Manuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Parma, Edward J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Naranjo, Gerald E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lippert, Lance L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-01

    This document presents the facilit y - recommended characteri zation o f the neutron, prompt gamma - ray, and delayed gamma - ray radiation fields in the Annular Core Research Reactor ( ACRR ) for the cen tral cavity free - field environment with the 32 - inch pedestal at the core centerline. The designation for this environmen t is ACRR - FF - CC - 32 - cl. The neutron, prompt gamma - ray , and delayed gamma - ray energy spectra , uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma - ray fluence profiles within the experiment area of the cavity . Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples . Acknowledgements The authors wish to th ank the Annular Core Research Reactor staff and the Radiation Metrology Laboratory staff for their support of this work . Also thanks to David Ames for his assistance in running MCNP on the Sandia parallel machines.

  17. Neutron Reference Benchmark Field Specification: ACRR 44 Inch Lead-Boron (LB44) Bucket Environment (ACRR-LB44-CC-32-CL).

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Richard Manuel [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Parma, Edward J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Griffin, Patrick J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This report was put together to support the International Atomic Energy Agency (IAEA) REAL- 2016 activity to validate the dosimetry community’s ability to use a consistent set of activation data and to derive consistent spectral characterizations. The report captures details of integral measurements taken in the Annular Core Research Reactor (ACRR) central cavity with the 44 inch Lead-Boron (LB44) bucket, reference neutron benchmark field. The field is described and an “a priori” calculated neutron spectrum is reported, based on MCNP6 calculations, and a subject matter expert (SME) based covariance matrix is given for this “a priori” spectrum. The results of 31 integral dosimetry measurements in the neutron field are reported.

  18. Description and operating performance of a parallel-rail electric-arc system with helium driver gas for the Langley 6-inch expansion tube

    Science.gov (United States)

    Moore, J. A.

    1976-01-01

    A parallel-rail arc-discharge system to heat and pressurize the initial helium driver gas of the Langley 6-inch expansion tube is described. This system was designed for a 2.44-m-long driver vessel rated at 138 MPa, with a distance between rails of 20.3 cm. Electric energy was obtained from a capacitor storage system rated at 12,000 V with a maximum energy of 5 MJ. Tests were performed over a range of energy from 1.74 MJ to the maximum value. The operating experience and system performance are discussed, along with results from a limited number of expansion-tube tests with air and carbon dioxide as test gases.

  19. Height-diameter allometry of tropical forest trees

    Directory of Open Access Journals (Sweden)

    T. R. Feldpausch

    2011-05-01

    Full Text Available Tropical tree height-diameter (H:D relationships may vary by forest type and region making large-scale estimates of above-ground biomass subject to bias if they ignore these differences in stem allometry. We have therefore developed a new global tropical forest database consisting of 39 955 concurrent H and D measurements encompassing 283 sites in 22 tropical countries. Utilising this database, our objectives were:

    1. to determine if H:D relationships differ by geographic region and forest type (wet to dry forests, including zones of tension where forest and savanna overlap.

    2. to ascertain if the H:D relationship is modulated by climate and/or forest structural characteristics (e.g. stand-level basal area, A.

    3. to develop H:D allometric equations and evaluate biases to reduce error in future local-to-global estimates of tropical forest biomass.

    Annual precipitation coefficient of variation (PV, dry season length (SD, and mean annual air temperature (TA emerged as key drivers of variation in H:D relationships at the pantropical and region scales. Vegetation structure also played a role with trees in forests of a high A being, on average, taller at any given D. After the effects of environment and forest structure are taken into account, two main regional groups can be identified. Forests in Asia, Africa and the Guyana Shield all have, on average, similar H:D relationships, but with trees in the forests of much of the Amazon Basin and tropical Australia typically being shorter at any given D than their counterparts elsewhere. The region-environment-structure model with the lowest Akaike's information criterion and lowest deviation estimated stand-level H across all plots to within amedian −2.7 to 0.9% of the true value. Some of the plot-to-plot variability in

  20. Laser ablation studies of solid aerosols on the Baltic coast

    Directory of Open Access Journals (Sweden)

    Robert Jaworski

    2004-09-01

    Full Text Available A Berner cascade impactor was used for the separation of solid urban aerosols in two localities of the Baltic coastal macro-region - Słupsk and Hel - in different seasons and weathers. Ten ranges of aerodynamic diameters between 0.009 and 8.11 µm were used. The elementary composition for each diameter was obtained in a complex procedure consisting of laser ablation of deposits, then their successive ionization in an inductively coupled plasma generator, and finally, mass selection in a quadrupole spectrometer. Despite its complexity, the chemical element analysis method proved to be versatile, allowing the identification air pollution from natural and industrial sources, and road traffic.

  1. Universal decoherence in solids.

    Science.gov (United States)

    Chudnovsky, Eugene M

    2004-03-26

    Symmetry implications for the decoherence of quantum oscillations of a two-state system in a solid are studied. When the oscillation frequency is small compared to the Debye frequency, the universal lower bound on the decoherence due to the atomic environment is derived in terms of the macroscopic parameters of the solid, with no unknown interaction constants.

  2. Effect of Coal Contaminants on Solid Oxide Fuel System Performance and Service Life

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, Gopala N.; Jayaweera, Palitha; Perez, Jordi; Hornbostel, M.; Albritton, John R.; Gupta, Raghubir P.

    2007-10-31

    The U.S. Department of Energy’s SECA program envisions the development of high-efficiency, low-emission, CO2 sequestration-ready, and fuel-flexible technology to produce electricity from fossil fuels. One such technology is the integrated gasification-solid oxide fuel cell (SOFC) that produces electricity from the gas stream of a coal gasifier. SOFCs have high fuel-to-electricity conversion efficiency, environmental compatibility (low NOx production), and modularity. The primary objective of the Phase I study was to determine the sensitivity of the performance of solid oxide fuel cells to trace level contaminants present in a coal-derived gas stream in the temperature range 700° to 900°C. Laboratory-scale tests were performed with 1-inch diameter solid oxide fuel cells procured from InDec B.V., Netherlands. These cells produce 0.15, 0.27, and 0.35 W/cm2 at 700°, 750°, and 800°C, respectively, in a H2 anode feed and are expected to be stable within 10% of the original performance over a period of 2000 h. A simulated coal-derived gas containing 30.0% CO, 30.6% H2 11.8% CO2, 27.6% H2O was used at a rate of ~100 standard cm3/min to determine the effect of contaminants on the electrical performance of the cells. Alumina or zirconia components were used for the gas manifold to prevent loss of contaminants by reaction with the surfaces of the gas manifold Short-term accelerated tests were conducted with several contaminants including As, P, CH3Cl, HCl, Hg, Sb, and Zn vapors. In these tests, AsH3, PH3, Cd vapor and CH3Cl identified as the potential contaminants that can affect the electrical performance of SOFCs. The effect of some of these contaminants varied with the operating temperature. Cell failure due to contact break inside the anode chamber occurred when the cell was exposed to 10 ppm arsenic vapor at 800°C. The electrical performance of SOFC

  3. Food intake in relation to pouch volume, stoma diameter, and pouch emptying after gastroplasty for morbid obesity

    DEFF Research Database (Denmark)

    Andersen, T; Pedersen, B H; Henriksen, Jens Henrik Sahl

    1988-01-01

    associated with the change of solid foods consumed (by weight, p = 0.01; by energy content, p = 0.02). The change of pouch volume was negatively associated with the change of energy from beverages (p = 0.005). In conclusion, it seems impossible to tailor the reduction of food intake through adjustments...... of the surgical dimensions, at least within the ranges of our observations. Increased food consumption and decreased energy intake with beverages may be caused by late dilations, or vice versa.......This study investigated possible determinants of food intake change after gastroplastry. Preoperatively and 6 and 12 months postoperatively, 27 morbidly obese patients were prospectively examined with 7-day food registration and radiologic measurement of pouch volume and stoma diameter. Pouch...

  4. Lubrication with solids.

    Science.gov (United States)

    Buckley, D. H.; Johnson, R. L.

    1972-01-01

    Brief discussion of the historical background, variety range, chemistry, physics, and other properties of solid lubricants, and review of their current uses. The widespread use of solid lubricants did not occur until about 1947. At present, they are the object of such interest that a special international conference on their subject was held in 1971. They are used at temperatures beyond the useful range of conventional lubricating oils and greases. Their low volatility provides them with the capability of functioning effectively in vacuum and invites their use in space applications. Their high load carrying ability makes them useful with heavily loaded components. Solid lubricants, however, do lack some of the desirable properties of conventional lubricants. Unlike oils and greases, which have fluidity and can continuously be carried back into contact with lubricated surfaces, solid lubricants, because of their immobility, have finite lives. Also, oils and greases can carry away frictional heat from contacting surfaces, while solid lubricants cannot.

  5. Applied mechanics of solids

    CERN Document Server

    Bower, Allan F

    2009-01-01

    Modern computer simulations make stress analysis easy. As they continue to replace classical mathematical methods of analysis, these software programs require users to have a solid understanding of the fundamental principles on which they are based. Develop Intuitive Ability to Identify and Avoid Physically Meaningless Predictions Applied Mechanics of Solids is a powerful tool for understanding how to take advantage of these revolutionary computer advances in the field of solid mechanics. Beginning with a description of the physical and mathematical laws that govern deformation in solids, the text presents modern constitutive equations, as well as analytical and computational methods of stress analysis and fracture mechanics. It also addresses the nonlinear theory of deformable rods, membranes, plates, and shells, and solutions to important boundary and initial value problems in solid mechanics. The author uses the step-by-step manner of a blackboard lecture to explain problem solving methods, often providing...

  6. Carbon-based strong solid acid for cornstarch hydrolysis

    Science.gov (United States)

    Nata, Iryanti Fatyasari; Irawan, Chairul; Mardina, Primata; Lee, Cheng-Kang

    2015-10-01

    Highly sulfonated carbonaceous spheres with diameter of 100-500 nm can be generated by hydrothermal carbonization of glucose in the presence of hydroxyethylsulfonic acid and acrylic acid at 180 °C for 4 h. The acidity of the prepared carbonaceous sphere C4-SO3H can reach 2.10 mmol/g. It was used as a solid acid catalyst for the hydrolysis of cornstarch. Total reducing sugar (TRS) concentration of 19.91 mg/mL could be obtained by hydrolyzing 20 mg/mL cornstarch at 150 °C for 6 h using C4-SO3H as solid acid catalyst. The solid acid catalyst demonstrated good stability that only 9% decrease in TRS concentration was observed after five repeat uses. The as-prepared carbon-based solid acid catalyst can be an environmentally benign replacement for homogeneous catalyst.

  7. Catalyst and its diameter dependent growth kinetics of CVD grown GaN nanowires

    International Nuclear Information System (INIS)

    Samanta, Chandan; Chander, D. Sathish; Ramkumar, J.; Dhamodaran, S.

    2012-01-01

    Graphical abstract: GaN nanowires with controlled diameter and aspect ratio has been grown using a simple CVD technique. The growth kinetics of CVD grown nanowires investigated in detail for different catalysts and their diameters. A critical diameter important to distinguish the growth regimes has been discussed in detail. The results are important which demonstrates the growth of diameter and aspect ratio controlled GaN nanowires and also understand their growth kinetics. Highlights: ► Controlled diameter and aspect ratio of GaN nanowires achieved in simple CVD reactor. ► Nanowire growth kinetics for different catalyst and its diameters were understood. ► Adatoms vapor pressure inside reactor plays a crucial role in growth kinetics. ► Diffusion along nanowire sidewalls dominate for gold and nickel catalysts. ► Gibbs–Thomson effect dominates for palladium catalyst. -- Abstract: GaN nanowires were grown using chemical vapor deposition with controlled aspect ratio. The catalyst and catalyst-diameter dependent growth kinetics is investigated in detail. We first discuss gold catalyst diameter dependent growth kinetics and subsequently compare with nickel and palladium catalyst. For different diameters of gold catalyst there was hardly any variation in the length of the nanowires but for other catalysts with different diameter a strong length variation of the nanowires was observed. We calculated the critical diameter dependence on adatoms pressure inside the reactor and inside the catalytic particle. This gives an increasing trend in critical diameter as per the order gold, nickel and palladium for the current set of experimental conditions. Based on the critical diameter, with gold and nickel catalyst the nanowire growth was understood to be governed by limited surface diffusion of adatoms and by Gibbs–Thomson effect for the palladium catalyst.

  8. Inter-observer reproducibility of semi-automatic tumor diameter measurement and volumetric analysis in patients with lung cancer.

    Science.gov (United States)

    Dinkel, J; Khalilzadeh, O; Hintze, C; Fabel, M; Puderbach, M; Eichinger, M; Schlemmer, H-P; Thorn, M; Heussel, C P; Thomas, M; Kauczor, H-U; Biederer, J

    2013-10-01

    Therapy monitoring in oncologic patient requires precise measurement methods. In order to improve the precision of measurements, we used a semi-automated generic segmentation algorithm to measure the size of large lung cancer tumors. The reproducibility of computer-assisted measurements were assessed and compared with manual measurements. CT scans of 24 consecutive lung cancer patients who were referred to our hospital over a period of 6 months were analyzed. The tumor sizes were measured manually by 3 independent radiologists, according to World Health Organization (WHO) and the Revised Response Evaluation Criteria in Solid Tumors (RECIST) guidelines. At least 10 months later, measurements were repeated semi-automatically on the same scans by the same radiologists. The inter-observer reproducibility of all measurements was assessed and compared between manual and semi-automated measurements. Manual measurements of the tumor longest diameter were significantly (p < 0.05) smaller compared with the semi-automated measurements. The intra-rater correlations coefficients were significantly higher for measurements of longest diameter (intra-class correlation coefficients: 0.998 vs. 0.986; p < 0.001) and area (0.995 vs. 0.988; p = 0.032) using semi-automated compared with manual method. The variation coefficient for manual measurement of the tumor area (WHO guideline, 15.7% vs. 7.3%) and the longest diameter (RECIST guideline, 7.7% vs. 2.7%) was 2-3 times that of semi-automated measurement. By using computer-assisted size assessment in primary lung tumor, interobserver-variability can be reduced to about half to one-third compared to standard manual measurements. This indicates a high potential value for therapy monitoring in lung cancer patients. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Solid Lithium Ion Conductors (SLIC) for Lithium Solid State Batteries

    Data.gov (United States)

    National Aeronautics and Space Administration — To identify the most lithium-ion conducting solid electrolytes for lithium solid state batteries from the emerging types of solid electrolytes, based on a...

  10. Using quadratic mean diameter and relative spacing index to enhance height-diameter and crown ratio models fitted to longitudinal data

    Science.gov (United States)

    Pradip Saud; Thomas B. Lynch; Anup K. C.; James M. Guldin

    2016-01-01

    The inclusion of quadratic mean diameter (QMD) and relative spacing index (RSI) substantially improved the predictive capacity of height–diameter at breast height (d.b.h.) and crown ratio models (CR), respectively. Data were obtained from 208 permanent plots established in western Arkansas and eastern Oklahoma during 1985–1987 and remeasured for the sixth time (2012–...

  11. Calibration of the Diameter Distribution Derived from the Area-based Approach with Individual Tree-based Diameter Estimates Using the Airborne Laser Scanning

    Science.gov (United States)

    Xu, Q.; Hou, Z.; Maltamo, M.; Tokola, T.

    2015-12-01

    Diameter distributions of trees are important indicators of current forest stand structure and future dynamics. A new method was proposed in the study to combine the diameter distributions derived from the area-based approach (ABA) and the diameter distribution derived from the individual tree detection (ITD) in order to obtain more accurate forest stand attributes. Since dominant trees can be reliably detected and measured by the Lidar data via the ITD, the focus of the study is to retrieve the suppressed trees (trees that were missed by the ITD) from the ABA. Replacement and histogram matching were respectively employed at the plot level to retrieve the suppressed trees. Cut point was detected from the ITD-derived diameter distribution for each sample plot to distinguish dominant trees from the suppressed trees. The results showed that calibrated diameter distributions were more accurate in terms of error index and the entire growing stock estimates. Compared with the best performer between the ABA and the ITD, calibrated diameter distributions decreased the relative RMSE of the estimated entire growing stock, saw log and pulpwood fractions by 2.81%, 3.05% and 7.73% points respectively. Calibration improved the estimation of pulpwood fraction significantly, resulting in a negligible bias of the estimated entire growing stock.

  12. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    Science.gov (United States)

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  13. A Study on Optimal Sizing of Pipeline Transporting Equi-sized Particulate Solid-Liquid Mixture

    International Nuclear Information System (INIS)

    Asim, Taimoor; Mishra, Rakesh; Pradhan, Suman; Ubbi, Kuldip

    2012-01-01

    Pipelines transporting solid-liquid mixtures are of practical interest to the oil and pipe industry throughout the world. Such pipelines are known as slurry pipelines where the solid medium of the flow is commonly known as slurry. The optimal designing of such pipelines is of commercial interests for their widespread acceptance. A methodology has been evolved for the optimal sizing of a pipeline transporting solid-liquid mixture. Least cost principle has been used in sizing such pipelines, which involves the determination of pipe diameter corresponding to the minimum cost for given solid throughput. The detailed analysis with regard to transportation of slurry having solids of uniformly graded particles size has been included. The proposed methodology can be used for designing a pipeline for transporting any solid material for different solid throughput.

  14. PLGA and PHBV Microsphere Formulations and Solid-State Characterization

    DEFF Research Database (Denmark)

    Yang, Chiming; Plackett, David; Needham, David

    2009-01-01

    To develop and characterize the solid-state properties of poly(DL-lactic-co-glycolic acid) (PLGA) and poly(3-hydroxybutyric acid-co-3-hydroxyvaleric acid) (PHBV) microspheres for the localized and controlled release of fusidic acid (FA). The effects of FA loading and polymer composition on the mean...... diameter, encapsulation efficiency and FA released from the microspheres were determined. The solid-state and phase separation properties of the microspheres were characterized using DSC, XRPD, Raman spectroscopy, SEM, laser confocal and real time recording of single microspheres formation. Above a loading...

  15. Automatic calculation of tree diameter from stereoscopic image pairs using digital image processing.

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu

    2012-06-20

    Automatic operations play an important role in societies by saving time and improving efficiency. In this paper, we apply the digital image processing method to the field of lumbering to automatically calculate tree diameters in order to reduce culler work and enable a third party to verify tree diameters. To calculate the cross-sectional diameter of a tree, the image was first segmented by the marker-controlled watershed transform algorithm based on the hue saturation intensity (HSI) color model. Then, the tree diameter was obtained by measuring the area of every isolated region in the segmented image. Finally, the true diameter was calculated by multiplying the diameter computed in the image and the scale, which was derived from the baseline and disparity of correspondence points from stereoscopic image pairs captured by rectified configuration cameras.

  16. A Fractal Model for the Maximum Droplet Diameter in Gas-Liquid Mist Flow

    Directory of Open Access Journals (Sweden)

    Xiao-Hua Tan

    2013-01-01

    Full Text Available Distribution characteristics of liquid droplet size are described using the fractal theory for liquid droplet size distribution in gas-liquid mist flow. Thereby, the fractal expression of the maximum droplet diameter is derived. The fractal model for maximum droplet diameter is obtained based on the internal relationship between maximum droplet diameter and the droplet fractal dimension, which is obtained by analyzing the balance between total droplet surface energy and total gas turbulent kinetic energy. Fractal model predictions of maximum droplet diameter agree with the experimental data. Maximum droplet diameter and droplet fractal dimension are both found to be related to the superficial velocity of gas and liquid. Maximum droplet diameter decreases with an increase in gas superficial velocity but increases with an increase in liquid superficial velocity. Droplet fractal dimension increases with an increase in gas superficial velocity but decreases with an increase in liquid superficial velocity. These are all consistent with the physical facts.

  17. Diameter Tuning of Single-Walled Carbon Nanotubes by Diffusion Plasma CVD

    Directory of Open Access Journals (Sweden)

    Toshiaki Kato

    2011-01-01

    Full Text Available We have realized a diameter tuning of single-walled carbon nanotubes (SWNTs by adjusting process gas pressures with plasma chemical vapor deposition (CVD. Detailed photoluminescence measurements reveal that the diameter distribution of SWNTs clearly shifts to a large-diameter region with an increase in the pressure during plasma CVD, which is also confirmed by Raman scattering spectroscopy. Based on the systematical investigation, it is found that the main diameter of SWNTs is determined by the pressure during the heating in an atmosphere of hydrogen and the diameter distribution is narrowed by adjusting the pressure during the plasma generation. Our results could contribute to an application of SWNTs to high-performance thin-film transistors, which requires the diameter-controlled semiconductor-rich SWNTs.

  18. A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis.

    Science.gov (United States)

    Zalewska, Ewa; Nandedkar, Sanjeev D; Hausmanowa-Petrusewicz, Irena

    2012-12-01

    We have used computer simulation to study the relationship between the muscle fiber diameter and parameters: peak-to-peak amplitude and duration of the negative peak of the muscle fiber action potential. We found that the negative peak duration is useful in the determination of fiber diameter via the diameter dependence of conduction velocity. We have shown a direct link between the underlying physiology and the measurements characterizing single fiber potential. Using data from simulations, a graphical tool and an analytical method to estimate the muscle fiber diameter from the recorded action potential has been developed. The ability to quantify the fiber diameter can add significantly to the single fiber electromyography examination. It may help study of muscle fiber diameter variability and thus compliment the muscle biopsy studies.

  19. The solid state maser

    CERN Document Server

    Orton, J W; Walling, J C; Ter Haar, D

    1970-01-01

    The Solid State Maser presents readings related to solid state maser amplifier from the first tentative theoretical proposals that appeared in the early 1950s to the successful realization of practical devices and their application to satellite communications and radio astronomy almost exactly 10 years later. The book discusses a historical account of the early developments (including that of the ammonia maser) of solid state maser; the properties of paramagnetic ions in crystals; the development of practical low noise amplifiers; and the characteristics of maser devices designed for communica

  20. Laser cooling of solids

    OpenAIRE

    Nemova, Galina

    2009-01-01

    Parallel to advances in laser cooling of atoms and ions in dilute gas phase, which has progressed immensely, resulting in physics Nobel prizes in 1997 and 2001, major progress has recently been made in laser cooling of solids. I compare the physical nature of the laser cooling of atoms and ions with that of the laser cooling of solids. I point out all advantages of this new and very promising area of laser physics. Laser cooling of solids (optical refrigeration) at the present time can be lar...

  1. Applications in solid mechanics

    DEFF Research Database (Denmark)

    Ølgaard, Kristian Breum; Wells, Garth N.

    2012-01-01

    Problems in solid mechanics constitute perhaps the largest field of application of finite element methods. The vast majority of solid mechanics problems involve the standard momentum balance equation, posed in a Lagrangian setting, with different models distinguished by the choice of nonlinear...... or linearized kinematics, and the constitutive model for determining the stress. For some common models, the constitutive relationships are rather complex. This chapter addresses a number of canonical solid mechanics models in the context of automated modeling, and focuses on some pertinent issues that arise...

  2. Positron annihilation characteristics in multi-wall carbon nanotubes with different average diameters

    International Nuclear Information System (INIS)

    Tuyen, L A; Khiem, D D; Phuc, P T; Kajcsos, Zs; Lázár, K; Tap, T D

    2013-01-01

    Positron lifetime spectroscopy was used to study multi-wall carbon nanotubes. The measurements were performed in vacuum on the samples having different average diameters. The positron lifetime values depend on the nanotube diameter. The results also show an influence of the nanotube diameter on the positron annihilation intensity on the nanotube surface. The change in the annihilation probability is described and interpreted by the modified diffusion model introducing the positron escape rate from the nanotubes to their external surface.

  3. Use of Gumbel and Weibull functions to model extreme values of diameter distributions in forest stands

    OpenAIRE

    Gorgoso-Varela, J. Javier; Rojo-Alboreca, Alberto

    2014-01-01

    International audience; & Context Families of the Gumbel (type I), Fréchet (type II) and Weibull (type III) distributions can be combined in the generalized extreme value (GEV) family of distributions. Maximum and minimum values of diameters in forest stands can be used in forest modelling, mainly to define parameters of the functions used in diameter class models as well as in some practical cases, such as modelling maximum diameters for sawing and processing purposes. & Aims The purpose of ...

  4. Investigation of the ramp testing behaviour of fuel pins with different diameters

    International Nuclear Information System (INIS)

    Pott, G.; Herren, M.; Wigger, B.

    1979-09-01

    The aim of these experiments was the investigation of the influence of different fuel pin diameter on the ramp testing behaviour. Fuel elements with diameter between 10,75 and 15,6 mm and different cladding thickness had been ramptested in the HBWR (Halden Boiling Water Reactor) after preirradiated in the same facility. Fuel pins with the smallest diameter of 10,75 mm failed. This was indicated by fission gas release measurement. Metallographic examination showed these failure were caused by hydride blisters. A systematic influence of fuel pin diameter and cladding thickness on the ramptesting behaviour was not observed. (orig.) [de

  5. Spontaneous and controlled-diameter synthesis of single-walled and few-walled carbon nanotubes

    Science.gov (United States)

    Inoue, Shuhei; Lojindarat, Supanat; Kawamoto, Takahiro; Matsumura, Yukihiko; Charinpanitkul, Tawatchai

    2018-05-01

    In this study, we explored the spontaneous and controlled-diameter growth of carbon nanotubes. We evaluated the effects of catalyst density, reduction time, and a number of catalyst coating on the substrate (for multi-walled carbon nanotubes) on the diameter of single-walled carbon nanotubes and the number of layers in few-walled carbon nanotubes. Increasing the catalyst density and reduction time increased the diameters of the carbon nanotubes, with the average diameter increasing from 1.05 nm to 1.86 nm for single-walled carbon nanotubes. Finally, we succeeded in synthesizing a significant double-walled carbon nanotube population of 24%.

  6. Body hair scores and total hair diameters in healthy women in the Kirikkale Region of Turkey.

    Science.gov (United States)

    Sagsoz, Nevin; Kamaci, Mansur; Orbak, Zerrin

    2004-06-30

    It was aimed to determine the normal hair scores of women of Kirikkale region according to the Ferriman- Gallwey scale and to investigate the relationship between the hair shaft diameter and hair scores. Hair scores were calculated in 204 healthy women, and hair shaft diameters were measured from the hair samples collected from 60 patients. Body mass index, waist to hip ratio, insulin resistance and blood androgen levels were determined. Neutral, hormonal and total hair scores were 2.1 1.4, 3.1 2.7 and 5.2 3.6, respectively. The average total hair diameter and hormonal hair diameter were 191.93 90.49 m and 121.8 75.9 m respectively. The correlation between total hair diameter and total hair score was statistically significant (r=0.704 p 0.001). Also, the correlation between hormonal hair diameter and hormonal hair score was statistically significant (r=0.724 p 0.001). While hair scores and diameters show meaningful positive correlation with androgen levels, they show negative correlation with age. In our population, 95% value of total hair score was 11, and for the hormonal score, it was 9. Hair diameters increase with hair score, regardless of total or hormonal of hair scores. Hair scores and hair diameters may be affected by blood androgens in healthy women.

  7. Root diameter variations explained by anatomy and phylogeny of 50 tropical and temperate tree species.

    Science.gov (United States)

    Gu, Jiacun; Xu, Yang; Dong, Xueyun; Wang, Hongfeng; Wang, Zhengquan

    2014-04-01

    Root diameter, a critical indicator of root physiological function, varies greatly among tree species, but the underlying mechanism of this high variability is unclear. Here, we sampled 50 tree species across tropical and temperate zones in China, and measured root morphological and anatomical traits along the first five branch orders in each species. Our objectives were (i) to reveal the relationships between root diameter, cortical thickness and stele diameter among tree species in tropical and temperate forests, and (ii) to investigate the relationship of both root morphological and anatomical traits with divergence time during species radiation. The results showed that root diameter was strongly affected by cortical thickness but less by stele diameter in both tropical and temperate species. Changes in cortical thickness explained over 90% of variation in root diameter for the first order, and ∼74-87% for the second and third orders. Thicker roots displayed greater cortical thickness and more cortical cell layers than thinner roots. Phylogenetic analysis demonstrated that root diameter, cortical thickness and number of cortical cell layers significantly correlated with divergence time at the family level, showing similar variation trends in geological time. The results also suggested that trees tend to decrease their root cortical thickness rather than stele diameter during species radiation. The close linkage of variations in root morphology and anatomy to phylogeny as demonstrated by the data from the 50 tree species should provide some insights into the mechanism of root diameter variability among tree species.

  8. Estimation of the fustal diameter on the central knotty cylinder in oak basal logs, Chile

    Directory of Open Access Journals (Sweden)

    Patricio Corvalán Vera

    2018-01-01

    Full Text Available In order to determine the diameter of the central knotted cylinder both alive and dead, a total of 60 trees belonging to the upper quartile of diametric classes in unmanaged renewal of N. obliqua from the Maule foothills were sampled. It is assumed that these are determined by the lowest living and dead branch present in tree height, respectively. We analyzed the relationships between the diameter of the central knotty cylinder, and the diameters at the lower end of logs 1.2, 2.4 and 3.6 m above the stump, the normal diameter and the insertion height of the first branch. From the analysis it is deduced that: i the diameter of the live and dead central knotted cylinder increases linearly with the normal diameter of the tree, ii that the diameter at the smaller end of the logs increases as it does and decreases as increases in height above the ground and iii that the fustal diameter on the dead central knotty cylinder increases linearly with the normal diameter and the insertion height of the lowest dead branch of the tree, allowing to determine the zone of occlusion of the knots of the tree.

  9. Measurement of Vein Diameter for Peripherally Inserted Central Catheter (PICC) Insertion: An Observational Study.

    Science.gov (United States)

    Sharp, Rebecca; Cummings, Melita; Childs, Jessie; Fielder, Andrea; Mikocka-Walus, Antonina; Grech, Carol; Esterman, Adrian

    2015-01-01

    Choosing an appropriately sized vein reduces the risk of venous thromboembolism associated with peripherally inserted central catheters. This observational study described the diameters of the brachial, basilic, and cephalic veins and determined the effect of patient factors on vein size. Ultrasound was used to measure the veins of 176 participants. Vein diameter was similar in both arms regardless of hand dominance and side. Patient factors-including greater age, height, and weight, as well as male gender-were associated with increased vein diameter. The basilic vein tended to have the largest diameter statistically. However, this was the case in only 55% of patients.

  10. Layered inorganic solids

    Czech Academy of Sciences Publication Activity Database

    Čejka, Jiří; Morris, R. E.; Nachtigall, P.; Roth, Wieslaw Jerzy

    2014-01-01

    Roč. 43, č. 27 (2014), s. 10274-10275 ISSN 1477-9226 Institutional support: RVO:61388955 Keywords : layered inorganic solids * physical chemistry * catalysis Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.197, year: 2014

  11. Solid State Grid Modulator

    National Research Council Canada - National Science Library

    Jones, Franklin

    2001-01-01

    This program was for the design, construction and test of two Solid State Grid Modulators to provide enhanced performance and improved reliability in existing S-band radar transmitters at the Rome Research Site...

  12. The solid waste dilemma

    Science.gov (United States)

    Amey, E.B.; Russell, J.A.; Hurdelbrink, R.J.

    1996-01-01

    In 1976, the U.S. Congress enacted the Resource Conservation and Recovery Act (RCRA) to further address the problem of increasing industrial and municipal waste. The main objectives of RCRA were to responsibly manage hazardous and solid waste and to procure materials made from recovered wastes. To fulfill these objectives, four main programs of waste management were developed. These programs were defined under Subtitle C, the Hazardous Waste Program; Subtitle D, the Solid Waste Program; Subtitle I, the Underground Storage Tank Program; and Subtitle J, the Medical Waste Program. Subtitle D illustrates the solid waste dilemma occurring in the United States. Under this program, states are encouraged to develop and implement their own waste management plans. These plans include the promotion of recycling solid wastes and the closing and upgrading of all environmentally unsound dumps. ?? 1996 International Association for Mathematical Geology.

  13. Solid Waste Management Districts

    Data.gov (United States)

    Vermont Center for Geographic Information — The Solid waste management districts layer is part of a dataset that contains administrative boundaries for Vermont's Agency of Natural Resources. This dataset...

  14. Organic Molecular Solids

    CERN Document Server

    Schwoerer, Marcus

    2007-01-01

    This is the first comprehensive textbook on the physical aspects of organic solids. All phenomena which are necessary in order to understand modern technical applications are being dealt with in a way which makes the concepts of the topics accessible for students. The chapters - from the basics, production and characterization of organic solids and layers to organic semiconductors, superconductors and opto-electronical applications - have been arranged in a logical and well thought-out order.

  15. Solid polymer electrolytes

    Science.gov (United States)

    Abraham, Kuzhikalail M.; Alamgir, Mohamed; Choe, Hyoun S.

    1995-01-01

    This invention relates to Li ion (Li.sup.+) conductive solid polymer electrolytes composed of poly(vinyl sulfone) and lithium salts, and their use in all-solid-state rechargeable lithium ion batteries. The lithium salts comprise low lattice energy lithium salts such as LiN(CF.sub.3 SO.sub.2).sub.2, LiAsF.sub.6, and LiClO.sub.4.

  16. Heat transfer across the interface between nanoscale solids and gas.

    Science.gov (United States)

    Cheng, Chun; Fan, Wen; Cao, Jinbo; Ryu, Sang-Gil; Ji, Jie; Grigoropoulos, Costas P; Wu, Junqiao

    2011-12-27

    When solid materials and devices scale down in size, heat transfer from the active region to the gas environment becomes increasingly significant. We show that the heat transfer coefficient across the solid-gas interface behaves very differently when the size of the solid is reduced to the nanoscale, such as that of a single nanowire. Unlike for macroscopic solids, the coefficient is strongly pressure dependent above ∼10 Torr, and at lower pressures it is much higher than predictions of the kinetic gas theory. The heat transfer coefficient was measured between a single, free-standing VO(2) nanowire and surrounding air using laser thermography, where the temperature distribution along the VO(2) nanowire was determined by imaging its domain structure of metal-insulator phase transition. The one-dimensional domain structure along the nanowire results from the balance between heat generation by the focused laser and heat dissipation to the substrate as well as to the surrounding gas, and thus serves as a nanoscale power-meter and thermometer. We quantified the heat loss rate across the nanowire-air interface, and found that it dominates over all other heat dissipation channels for small-diameter nanowires near ambient pressure. As the heat transfer across the solid-gas interface is nearly independent of the chemical identity of the solid, the results reveal a general scaling relationship for gaseous heat dissipation from nanostructures of all solid materials, which is applicable to nanoscale electronic and thermal devices exposed to gaseous environments.

  17. Lyophilization -Solid Waste Treatment

    Science.gov (United States)

    Litwiller, Eric; Flynn, Michael; Fisher, John; Reinhard, Martin

    2004-01-01

    This paper discusses the development of a solid waste treatment system that has been designed for a Mars transit exploration mission. The technology described is an energy-efficient lyophilization technique that is designed to recover water from spacecraft solid wastes. Candidate wastes include feces, concentrated brines from water processors, and other solid wastes that contain free water. The system is designed to operate as a stand-alone process or to be integrated into the International Space Station Waste Collection System. In the lyophilization process, water in an aqueous waste is frozen and then sublimed, separating the waste into a dried solid material and liquid water. The sublimed water is then condensed in a solid ice phase and then melted to generate a liquid product. In the subject system the waste solids are contained within a 0.2 micron bio-guard bag and after drying are removed from the system and stored in a secondary container. This technology is ideally suited to applications such as the Mars Reference Mission, where water recovery rates approaching 100% are desirable but production of CO2 is not. The system is designed to minimize power consumption through the use of thermoelectric heat pumps. The results of preliminary testing of a prototype system and testing of the final configuration are provided. A mathematical model of the system is also described.

  18. Pengujian Tarik Dan Impak Pada Pengerjaan Pengelasan SMAW Dengan Mesin Genset Menggunakan Diameter Elektroda Yang Berbeda

    Directory of Open Access Journals (Sweden)

    M Zaenal Mawahib

    2017-02-01

    Full Text Available Pengaruh hasil sumber daya listrik yang dihasilkan dari mesin genset yaitu kemungkinan terjadinya lubang cacing dan retak, dan apabila arus yang terlalu rendah akan mengakibatkan kurangnya penembusan dan kemungkinan terak terperangkap tinggi, sehingga dapat mengakibatkan kekuatan dari sambungan lasan yang rendah. Pengujian pada sambungan pengelasan  yang berbeda diameter elektroda dengan menggunakan mesin genset, akan diperoleh kekuatan tarik dan kekuatan impak maksimum dari masing-masing material uji dan dapat diketahui pemilihan diameter elektroda yang paling baik digunakan untuk masing-masing pelat. Pengelasan menggunakan jenis sambungan butt joint (single V-groove dengan sudut 600, dengan diameter elektroda 3,2 mm dan 4 mm dengan tebal masing-masing material uji 8 mm dan 10 mm. Hasil pengujian didapatkan kuat tarik dari diameter elektroda 3,2 mm tebal material 8 mm adalah rata-rata 443,747 N/mm2, diameter elektroda 3,2 mm tebal material 10 mm adalah rata-rata 435,187 N/mm2, diameter elektroda 4 mm tebal material 8 mm adalah rata-rata 447,23 N/mm2, dan diameter elektroda 4 mm tebal material 10 mm adalah rata-rata 447,07 N/mm2. Hasil penelitian, modulus elastisitas dan tegangan luluh sama-sama memiliki kenaikan nilai, serta nilai pada regangan menurun. Sedangkan hasil pengujian impak didapatkan energi impak dari diameter elektroda 3,2 mm tebal material 8 mm adalah rata-rata 90,67 Joule, diameter elektroda 3,2 mm tebal material 10 mm adalah rata-rata 295,9 Joule, diameter elektroda 4 mm tebal material 8 mm adalah rata-rata 44,91 Joule, dan diameter elektroda 4 mm tebal material 10 mm adalah rata-rata 273,83 Joule.

  19. Crown-Stump Diameter Model for Parkia biglobosa Benth. Species in Makurdi, Benue State, Nigeria

    Directory of Open Access Journals (Sweden)

    O. Chukwu

    2017-07-01

    Full Text Available The crown of tree is the centre of physiological activity which gives an indication of the potential photosynthetic capacity on a tree. Though, its measurement remains a challenge in forest inventory task. The ability to predict crown diameter from stump diameter provides an effective technique of obtaining its estimate. This helps in detecting the excessive tree felling than actual requirements and wildlife suitability.The main objective of this study was to develop and test crown diameter prediction models for silvicultural management of naturally grown Parkia biglobosa within the University of Agriculture, Makurdi. Nine 100 m x 100 m temporary sample plots were established using simple random sampling method. Crown diameter and stump diameter were measured in all living P. biglobosa trees with stump diameter ≥10.0 cm. Least square method was used to convert the counted stumps into harvested crown dimension. Three linear and three non-linear models using stump diameter as the exploratory variable were developed and evaluated using the adjusted coefficient of determination (Adj.R2, standard error of estimate (SEE, prediction error sum of squares (PRESS and Akaike information criterion (AIC. The crown-stump diameter relationship was best described by the double logarithmic function with .The result showed that Crown diameter estimation was feasible even when the only information available is stump diameter.The resulting equation was tested for validation with independent data obtained from additional plots and was found to be desirable for estimating the crown diameter for Parkia biglobosa in Makurdi, Benue State, Nigeria.

  20. Understanding the Vapor-Liquid-Solid and Vapor-Solid-Solid Mechanisms of Si Nanowire Growth to Synthetically Encode Precise Nanoscale Morphology

    Science.gov (United States)

    Pinion, Christopher William

    Precise patterning of semiconductor materials utilizing top-down lithographic techniques is integral to the advanced electronics we use on a daily basis. However, continuing development of these lithographic technologies often results in the trade-off of either high cost or low throughput, and three-dimensional (3D) patterning can be difficult to achieve. Bottom-up, chemical methods to control the 3D nanoscale morphology of semiconductor nanostructures have received significant attention as a complementary technique. Semiconductor nanowires, nanoscale filaments of semiconductor material 10-500 nm in diameter and 1-50 microns in length, are an especially promising platform because the wire composition can be modulated during growth and the high aspect ratio, one-dimensional structure enables integration in a range of devices. In this thesis, we first report a bottom-up method to break the conventional "wire" symmetry and synthetically encode a high-resolution array of arbitrary shapes along the nanowire growth axis. Rapid modulation of phosphorus doping combined with selective wet-chemical etching enables morphological features as small as 10 nm to be patterned over wires more than 50 ?m in length. Next, our focus shifts to more fundamental studies of the nanowire synthetic mechanisms. We presented comprehensive experimental measurements on the growth rate of Au catalyzed Si nanowires and developed a kinetic model of vapor-liquid-solid growth. Our analysis revealed an abrupt transition from a diameter-independent growth rate that is limited by incorporation to a diameter-dependent growth rate that is limited by crystallization. While investigating the vapor-liquid-solid mechanism, we noticed instances of unique catalyst behavior. Upon further study, we showed that it is possible to instantaneously and reversibly switch the phase of the catalyst between a liquid and superheated solid state under isothermal conditions above the eutectic temperature. The solid catalyst

  1. Parametric study on vapor-solid-solid growth mechanism of multiwalled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Shukrullah, S., E-mail: zshukrullah@gmail.com [Center of Innovative Nanostructures and Nanodevices, Universiti Teknologi PETRONAS, 32610, Bandar Seri Iskandar, Perak (Malaysia); Mohamed, N.M. [Center of Innovative Nanostructures and Nanodevices, Universiti Teknologi PETRONAS, 32610, Bandar Seri Iskandar, Perak (Malaysia); Shaharun, M.S. [Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 32610, Bandar Seri Iskandar, Perak (Malaysia); Naz, M.Y. [Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610, Bandar Seri Iskandar, Perak (Malaysia)

    2016-06-15

    This study aimed at investigating the effect of the fluidized bed chemical vapor deposition (FBCVD) process parameters on growth mechanism, morphology and purity of the multiwalled carbon nanotubes (MWCNTs). Nanotubes were produced in a vertical FBCVD reactor by catalytic decomposition of ethylene over Al{sub 2}O{sub 3} supported nano-iron catalyst buds at different flow rates. FESEM, TEM, Raman spectroscopy and TGA thermograms were used to elaborate the growth parameters of the as grown MWCNTs. As the growth process was driven by the process temperatures well below the iron-carbon eutectic temperature (1147 °C), the appearance of graphite platelets from the crystallographic faces of the catalyst particles suggested a solid form of the catalyst during CNT nucleation. A vapor-solid-solid (VSS) growth mechanism was predicted for nucleation of MWCNTs with very low activation energy. The nanotubes grown at optimized temperature and ethylene flow rate posed high graphitic symmetry, purity, narrow diameter distribution and shorter inter-layer spacing. In Raman and TGA analyses, small I{sub D}/I{sub G} ratio and residual mass revealed negligible ratios of structural defects and amorphous carbon in the product. However, several structural defects and impurity elements were spotted in the nanotubes grown under unoptimized process parameters. - Graphical abstract: Arrhenius plot of relatively pure MWCNTs grown over Al2O3 supported nano-iron buds. - Highlights: • Vapor–solid–solid growth mechanism of MWCNTs was studied in a vertical FBCVD reactor. • MWCNTs were grown over Al2O3 supported nano-iron buds at very low activation energy. • FBCVD reactor was operated at temperatures well below the iron-carbon eutectic point. • Ideally graphitized structures were obtained at a process temperature of 800 °C. • Tube diameter revealed a narrow distribution of 20–25 nm at the optimum temperature.

  2. Fracture toughness of 6.4 mm (0.25 inch) Arc-Cast molybdenum and molybdenum-TZM plate at room temperature and 300 oC

    International Nuclear Information System (INIS)

    Shields, J.A. jr.; Lipetzky, P.; Mueller, A.J.

    2001-01-01

    The fracture toughness of 6.4 mm (0.25 inch) low carbon arc-cast (LCAC) molybdenum and arc-cast molybdenum-TZM alloy plate were measured at room temperature and 300 o C using compact tension specimens. The effect of crack plane orientation (longitudinal vs. transverse) and annealing practice (stress-relieved vs. recrystallized) were evaluated. Depending upon the test temperature either a standard K IC or a J-integral analysis was used to obtain the toughness value. At room temperature, regardless of alloy, orientation, or microstructure, fracture toughness values between 15 and 22 MPa m 1/2 (14 and 20 ksi in 1/2 ) were measured. These K IC values were consistent with measurements by other authors. Increasing temperature improves the toughness, due to the fact that one takes advantage of the ductile-brittle transition behavior of molybdenum. At 300 o C, the fracture toughness of recrystallized LCAC and arc-cast TZM molybdenum were also similar at approximately 64 MPa m 1/2 (58 ksi in 1/2 ). In the stress-relieved condition, however, the toughness of arc-cast TZM (91 MPa m 1/2 / 83 ksi in 1/2 ) was higher than that of the LCAC molybdenum (74 MPa m 1/2 / 67 ksi in 1/2 ). (author)

  3. MOVPE growth of GaN on 6-inch SOI-substrates: effect of substrate parameters on layer quality and strain

    Science.gov (United States)

    Lemettinen, J.; Kauppinen, C.; Rudzinski, M.; Haapalinna, A.; Tuomi, T. O.; Suihkonen, S.

    2017-04-01

    We demonstrate that higher crystalline quality, lower strain and improved electrical characteristics can be achieved in gallium nitride (GaN) epitaxy by using a silicon-on-insulator (SOI) substrate compared to a bulk silicon (Si) substrate. GaN layers were grown by metal-organic vapor phase epitaxy on 6-inch bulk Si and SOI wafers using the standard step graded AlGaN and AlN approach. The GaN layers grown on SOI exhibited lower strain according to x-ray diffraction analysis. Defect selective etching measurements suggested that the use of SOI substrate for GaN epitaxy reduces the dislocation density approximately by a factor of two. Furthermore, growth on SOI substrate allows one to use a significantly thinner AlGaN buffer compared to bulk Si. Synchrotron radiation x-ray topography analysis confirmed that the stress relief mechanism in GaN on SOI epitaxy is the formation of a dislocation network to the SOI device Si layer. In addition, the buried oxide layer significantly improves the vertical leakage characteristics as the onset of the breakdown is delayed by approximately 400 V. These results show that the GaN on the SOI platform is promising for power electronics applications.

  4. Effect of DS Concentration on the PRO Performance Using a 5-Inch Scale Cellulose Triacetate-Based Hollow Fiber Membrane Module

    Directory of Open Access Journals (Sweden)

    Masahiro Yasukawa

    2018-05-01

    Full Text Available In this study, pressure-retarded osmosis (PRO performance of a 5-inch scale cellulose triacetate (CTA-based hollow fiber (HF membrane module was evaluated under a wide range of operating conditions (0.0–6.0 MPa of applied pressure, 0.5–2.0 L/min feed solution (FS inlet flow rate, 1.0–6.0 L/min DS inlet flow rate and 0.1–0.9 M draw solution (DS concentration by using a PRO/reverse osmosis (RO hybrid system. The subsequent RO system for DS regeneration enabled the evaluation of the steady-stated module performance. In the case of pilot-scale module operation, since the DS dilution and the feed solution (FS up-concentration had occurred and was not negligible, unlike the lab-scale experiment, PRO performance strongly depended on operating conditions such as inlet flow rates of both the DS and FS concentration. To compare the module performance with different configurations, we proposed a converted parameter in which a difference of the packing density between the spiral wound (SW and the HF module was fairly considered. In the case of HF configuration, because of high packing density, volumetric-based performance was higher than that of SW module, that is, the required number of the module would be less than that of SW module in a full-scale PRO plant.

  5. Radiation Characterization Summary: ACRR Cadmium-Polyethylene (CdPoly) Bucket Located in the Central Cavity on the 32-Inch Pedestal at the Core Centerline

    Energy Technology Data Exchange (ETDEWEB)

    Parma, Edward J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Naranjo, Gerald E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kaiser, Krista Irene [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Arnold, James F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lippert, Lance L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Clovis, Ralph D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Martin, Lonnie E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Quirk, Thomas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vehar, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    This document presents the facility-recommended characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the Annular Core Research Reactor (ACRR) for the cadmium-polyethylene (CdPoly) bucket in the central cavity on the 32-inch pedestal at the core centerline. The designation for this environment is ACRR-CdPoly-CC-32-cl. The neutron, prompt gamma-ray, and delayed gamma-ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma-ray fluence profiles within the experiment area of the bucket. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples. Acknowledgements The authors wish to thank the Annular Core Research Reactor staff and the Radiation Metrology Laboratory staff for their support of this work. Also thanks to Drew Tonigan for helping field the activation experiments in ACRR, David Samuel for helping to finalize the drawings and get the parts fabricated, and Elliot Pelfrey for preparing the active dosimetry plots.

  6. Some Measurements of Noise Transmission and Stress Response of a 0.020-Inch Duralumin Panel in the Presence of Air Flow

    Science.gov (United States)

    Kantarges, George T.

    1960-01-01

    Noise transmission measurements were made for a 0.020-inch panel with and without air flow on its surface. Tests were conducted with both an absorbent and reverberant chamber behind the panel. Panel stresses for some of these tests were also determined. Noise spectra obtained inside the absorbent chamber with flow attached and flow not attached to the panel appeared to contain several peaks corresponding in frequency to panel vibration modes. These peaks were notably absent when the chamber was reverberant. The noise reduction through the test panel measured with the aid of an absorbent chamber for the flow-not-attached case is in general agreement with values predicted by the theoretical weight law, which assumes negligible panel stiffness. Corresponding data for the flow-attached case do not follow the weight law but rather indicate less noise reduction at the high frequencies. The main stress responses of the panel without air flow occurred at its fundamental vibration mode. In the presence of air flow the main response occurs in a vibration mode having a node line perpendicular to the direction of air flow.

  7. A Numerical Simulation of Base Shear Forces and Moments Exerted by Waves on Large Diameter Pile

    Directory of Open Access Journals (Sweden)

    You-liang Cheng

    2017-01-01

    Full Text Available To solve the problem of the dynamic variation of wave force diameter of pile foundation for offshore wind turbines, wave force and moment of large diameter pile foundation can be calculated. In this paper, simulation technique is used to calculate the wave force and moment of different large diameter pile foundation, and the base shear force and moment of the interval 20-degree phase angle are obtained by the base line of the pile. Under the action of a certain load, the complete stress variation of the pile foundation is obtained. According to the basic principle of diffraction theory, the process curve of large diameter pile, and analysis of wave force, diffraction force changes in a certain period of time interval. The results show that the wave after the large diameter pile formed around the vortex, large diameter pile base shear, and moment dynamic change is nonlinear in a complete cycle, the diameter of the pile increases by 0.5 m, and the wave force increases by about 5%, the results show that it provides certain reference value for the offshore pile foundation pile with large diameter primary site. Some significant results for practical application are discussed.

  8. Influence of tube and particle diameter on heat transport in packed beds

    NARCIS (Netherlands)

    Borkink, J.G.H.; Borkink, J.G.H.; Westerterp, K.R.

    1992-01-01

    Influence of the tube and particle diameter and shape, as well as their ratio, on the radial heat transport in packed beds has been studied. Heat transport experiments were performed with four different packings in three wall-cooled tubes, which differed in inner diameter only. Experimental values

  9. Computing Diameter in the Streaming and Sliding-Window Models (Preprint)

    National Research Council Canada - National Science Library

    Feigenbaum, Joan; Kannan, Sampath; Zhang, Jian

    2002-01-01

    We investigate the diameter problem in the streaming and sliding-window models. We show that, for a stream of n points or a sliding window of size n, any exact algorithm for diameter requires Omega(n) bits of space...

  10. Automated Nanofiber Diameter Measurement in SEM Images Using a Robust Image Analysis Method

    Directory of Open Access Journals (Sweden)

    Ertan Öznergiz

    2014-01-01

    Full Text Available Due to the high surface area, porosity, and rigidity, applications of nanofibers and nanosurfaces have developed in recent years. Nanofibers and nanosurfaces are typically produced by electrospinning method. In the production process, determination of average fiber diameter is crucial for quality assessment. Average fiber diameter is determined by manually measuring the diameters of randomly selected fibers on scanning electron microscopy (SEM images. However, as the number of the images increases, manual fiber diameter determination becomes a tedious and time consuming task as well as being sensitive to human errors. Therefore, an automated fiber diameter measurement system is desired. In the literature, this task is achieved by using image analysis algorithms. Typically, these methods first isolate each fiber in the image and measure the diameter of each isolated fiber. Fiber isolation is an error-prone process. In this study, automated calculation of nanofiber diameter is achieved without fiber isolation using image processing and analysis algorithms. Performance of the proposed method was tested on real data. The effectiveness of the proposed method is shown by comparing automatically and manually measured nanofiber diameter values.

  11. Board-Foot and Diameter Growth of Yellow-Poplar After Thinning

    Science.gov (United States)

    Donald E. Beck; Lino Della-Bianca

    1975-01-01

    Board-foot growth and yield of thinned yellow-poplar stands (Liriodendron tulipifera L.)is related to age, site index, residual basal area, and residual quadratic mean stand diameter after thinning. Diameter growth of individual trees is increased considerably by thinning. Equations describing growth and yield are based on data from 141 natura1 yellow-poplar stands in...

  12. The diameters of long positive streamers in atmospheric air under lightning impulse voltage

    Science.gov (United States)

    Chen, She; Zeng, Rong; Zhuang, Chijie

    2013-09-01

    Results from experiments on long positive streamers in atmospheric air under lightning impulse voltage are presented. The length of the rod-plane gap is 57 cm. The peak voltages applied to the gap are +210-290 kV. The voltage and current are measured through a synchronized measurement system. The streamer diameters are obtained by the analysis of photographs taken by an intensified CCD (ICCD) camera. The four continuous photographs of single streamer discharge allow us to investigate the variation of the streamer diameters with time. For the hemispherical electrode 2 cm in diameter the diameters vary in the range 1.6-6.3 mm when the streamer length is 2-16 cm. The streamers are thicker when the electrode diameter is doubled from 2 to 4 cm. There is a downward trend in the streamer diameter with the propagation of the streamer heads. Their diameters for higher voltage decline at a lower rate. A modified analytical model is also employed to explain the observations. The streamer head potential and the maximum electric field are analysed for long streamers of tens of centimetres. The model can predict the value of the streamer diameter for different streamer head positions during its propagation. The experimental data and the calculated results are in good agreement.

  13. Patterns of variability in the diameter of lateral roots in the banana root system.

    Science.gov (United States)

    Lecompte, François; Pagès, Loïc; Ozier-Lafontaine, Harry

    2005-09-01

    The relative importance of root system structure, plant carbon status and soil environment in the determination of lateral root diameter remains unclear, and was investigated in this study. Banana (Musa acuminata) plants were grown at various moderate levels of soil compaction in two distinct experiments, in a field experiment (FE) and in a glasshouse experiment (GE). Radiant flux density was 5 times lower in GE. The distribution of root diameter was measured for several root branching orders. Root diameters ranged between 0.09 and 0.52 mm for secondary roots and between 0.06 and 0.27 mm for tertiary roots. A relationship was found between the diameter of the parent bearing root and the median diameter of its laterals, which appears to be valid for a wide range of species. Mean lateral root diameter increased with distance to the base of the root and decreased with branching density [number of lateral roots per unit length of bearing root (cm(-1))]. Typical symptoms of low light availability were observed in GE. In this case, lateral root diameter variability was reduced. Although primary root growth was affected by soil compaction, no effects on lateral root diameter were observed.

  14. Subarachnoid space diameter in chromosomally abnormal fetuses at 11-13 weeks' gestation.

    Science.gov (United States)

    Ferreira, Carolina; Rouxinol-Dias, Ana Lidia; Loureiro, Teresa; Nicolaides, Kypros

    2018-01-16

    To examine the subarachnoid space diameters in chromosomally abnormal fetuses at 11-13 weeks' gestation. Stored three-dimensional (3D) ultrasound volumes of the fetal head at 11-13 weeks' gestation from 407 euploid and 88 chromosomally abnormal fetuses (trisomy 21, n = 40; trisomy 18, n = 19; trisomy 13, n = 7; triploidy, n = 14; Turner syndrome, n = 8) were analyzed. The subarachnoid space diameters, measured in the sagittal and transverse planes of the fetal head, in relation to biparietal diameter (BPD) in each group of aneuploidies was compared to that in euploid fetuses. A total of 20 head volumes were randomly selected and all the measurements were recorded by two different observers to examine the interobserver variability in measurements. In euploid fetuses, the anteroposterior, transverse and sagittal diameters of the subarachnoid space increased with BPD. The median of the observed to expected diameters for BPD were significantly increased in triploidy and trisomy 13 but were not significantly altered in trisomies 21 and 18 or Turner syndrome. In triploidy, the subarachnoid space diameters for BPD were above the 95th centile of euploid fetuses in 92.9% (13 of 14) cases. The intraclass reliability or agreement was excellent for all three subarachnoid space diameters. Most fetuses with triploidy at 11-13 weeks' gestation demonstrate increased subarachnoid space diameters.

  15. Carotid flow velocity/diameter ratio is a predictor of cardiovascular events in hypertensive patients

    DEFF Research Database (Denmark)

    Bellinazzi, Vera R; Cipolli, José A; Pimenta, Marcio V

    2015-01-01

    OBJECTIVE: The aim of this study was to evaluate the performance of common carotid artery diameter, flow velocity and flow velocity/artery diameter ratio as predictors of major adverse cardiovascular events (MACEs) in a sample of hypertensive patients. METHODS: A cohort of 403 hypertensive patien...

  16. Precise measurement of inner diameter of mono-capillary optic using X-ray imaging technique.

    Science.gov (United States)

    Kwon, Soonmu; Lim, Jae Hong; Namba, Yoshiharu; Chon, Kwon Su

    2017-11-16

    Mono-capillary optics have been applied to increase the performance of X-ray instruments. However, performance of a mono-capillary optic strongly depends on the shape accuracy, which is determined by the diameters of the inner hollow of the capillary along the axial direction. To precisely determine the inner diameter of the capillary optic used in X-ray imaging technique, which aims to replace the conventional method using a visible microscope. High spatial resolution X-ray images of the mono-capillary optic were obtained by a synchrotron radiation beamline. The inner diameter of the mono-capillary optic was measured and analyzed by the pixel values of the X-ray image. Edge enhancement effect was quite useful in determining the inner diameter, and the accuracy of the diameter determination was less than 1.32 μm. Many images obtained by scanning the mono-capillary optic along the axial direction were combined, and the axial profile, consisting of diameters along the axial direction, was obtained from the combined image. The X-ray imaging method could provide an accurate measurement with slope error of±19 μrad. Applying X-ray imaging technique to determine the inner diameter of a mono-capillary optic can contribute to increasing fabrication accuracy of the mono-capillary optic through a feedback process between the fabrication and measurement of its diameter.

  17. Sample preparation and scanning protocol for computerised analysis of root length and diameter

    NARCIS (Netherlands)

    Bouma, T.J.; Nielsen, K.F.; Koutstaal, B.P.

    2000-01-01

    Root length and diameter distribution are important characteristics to be considered when describing and comparing root systems. Root length and root-diameter distribution may be obtained in two ways: by microscopical measurements, which are laborious, or by computerised analysis, which is fast but

  18. Experimental use of large diameter boreholes in clay deposits for radioactive waste storage

    International Nuclear Information System (INIS)

    Dmitriev, S.; Litinsky, Y.; Tkachenko, A.; Guskov, A.

    2010-01-01

    Document available in extended abstract form only. Application of radioactive substances in industry, medicine and scientific research leads to generation of radioactive waste. The problem of improving reliability of isolation of the radioactive waste is becoming more acute with each passing year, and requirements for ecological safety are getting more and more stringent. Near surface repositories are usually considered to be acceptable for storage of waste with short lived radionuclides of low and intermediate activity level (LILW). However, the experience with LILW isolation in the near surface facilities in Russia has shown that a lot of operational and natural factors impact on the engineered barriers, and in case of traditional near surface repositories can cause failure of the isolation and discharge of radionuclides into near field. Operation of the old repositories with already contaminated surroundings and construction of similar new facilities require more and more area. SUE MosSIA 'RADON' from early 60-s was responsible for development of new approaches for waste treatment and long term storage. In accordance with this direction, research and experimental work is carried out both in field of upgrading safety for typical near surface repository constructions and in developing new repository types. Significant increase of LILW isolation reliability and land saving could be achieved by use of large diameter boreholes (LDB) drilled in clayey deposits for waste storage. Due to the depth of the borehole and depth of waste package emplacement, this type of facility can be considered as near surface facility. To date technology of LDB construction and its experimental use is being conducted in SUE Mos SIA 'Radon'. The diameter of a LDB type repository may range from 1 to 6 m depending on drilling rig capabilities and parameters of the repository in whole. The depth of the boreholes should depend on geological and hydro-geological conditions

  19. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound: Volume Versus Diameter.

    Science.gov (United States)

    Ghulam, Q M; Bredahl, K K; Lönn, L; Rouet, L; Sillesen, H H; Eiberg, J P

    2017-10-01

    Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. In total, 179 patients with small infrarenal AAAs (diameter 30-55 mm) were enrolled consecutively. At enrolment and at 12 month follow-up, maximum diameter, using dual plane technique, and three dimensional volume were measured. Based on a previous accuracy study, significant change in diameter and volume were defined as an increase exceeding the known range of variability (ROV) of each US technique; ±3.7 mm and ±8.8 mL, respectively. Post-hoc Kaplan-Meier analysis was performed to estimate time to conversion to treatment after the conclusion of the follow-up period between two groups. In total, 125 patients (70%) had an unchanged diameter during follow-up. In this group, 50 patients (40%) had an increasing aortic volume. Forty-five (83%) of the 54 patients with an increasing aortic diameter showed a corresponding volume increase. During a median follow-up of 367 days (364-380 days), a mean increase in diameter of 2.7 mm (±2.6 mm) and a mean increase in volume of 11.6 mL (±9.9 mL) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. In this cohort of small AAAs, 40% of patients with a stable diameter had an increasing volume at 12 month follow-up. From this perspective, 3D-US could have a future supplemental role in AAA surveillance programmes. Copyright © 2017 European Society for Vascular Surgery. Published

  20. Analysis of pressurized resistance vessel diameter changes with a low cost digital image processing device.

    Science.gov (United States)

    Fischer, J G; Mewes, H; Hopp, H H; Schubert, R

    1996-06-01

    A low cost digital image processing device (frame grabber) together with a program running under MS_WINDOWS for automatic on-line analysis of diameter changes of in vitro pressurized blood vessels with an inner diameter of 80-400 microns is presented. The frame grabber is designed to receive light microscopic images either from a video camera or from a VCR and to present the digitized image on the computer monitor. The special software allows to manipulate the image, e.g. filtering, calibrating, storing of vessel images, and detects the outer and inner border of the two vessel walls with a new, simple algorithm. The inner diameter and the vessel wall thickness are calculated and the diameter is presented in a diameter versus time diagram on the monitor screen. Further, these data are stored in an ASCII-file for later import into calculation and presentation programs like MS-EXCEL.

  1. Observation of Ureteric Diameter in Negative Intravenous Urogram in Hospital Universiti Kebangsaan Malaysia

    Science.gov (United States)

    Wong, Siong Lung; Abdul Hamid, Hamzaini

    2010-01-01

    Background: This study observed the widest ureteric diameter in negative intravenous urogram (IVU) examinations using low osmolar contrast media. Methods: We reviewed a total of one hundred and eighty four ureters from 92 negative IVUs. Results: The results show a mean diameter for the abdominal ureter of 4.19 mm with an SD of 1.27 mm and a mean pelvic ureteric diameter of 4.45 mm with an SD of 1.37 mm. The upper limits for abdominal ureter and pelvic ureter based on a confidence interval of 95% were 4.37 mm and 4.64 mm, respectively. Conclusions: There was no significant difference between the right and left ureteric diameter in both female and male subjects. There was no significant correlation between ureteric diameters and the age of subjects, from the second to the eighth decades. PMID:22135531

  2. Diameter structure modeling and the calculation of plantation volume of black poplar clones

    Directory of Open Access Journals (Sweden)

    Andrašev Siniša

    2004-01-01

    Full Text Available A method of diameter structure modeling was applied in the calculation of plantation (stand volume of two black poplar clones in the section Aigeiros (Duby: 618 (Lux and S1-8. Diameter structure modeling by Weibull function makes it possible to calculate the plantation volume by volume line. Based on the comparison of the proposed method with the existing methods, the obtained error of plantation volume was less than 2%. Diameter structure modeling and the calculation of plantation volume by diameter structure model, by the regularity of diameter distribution, enables a better analysis of the production level and assortment structure and it can be used in the construction of yield and increment tables.

  3. Optimization of solid state fermentation of sugar cane by Aspergillus niger considering particles size effect

    Energy Technology Data Exchange (ETDEWEB)

    Echevarria, J.; Rodriguez, L.J.A.; Delgado, G. (Instituto Cubano de Investigaciones de los Derivados de la Cana de Azucar (ICIDCA), La Habana (Cuba)); Espinosa, M.E. (Centro Nacional de Investigaciones Cientificas, La Habana (Cuba))

    1991-01-01

    The protein enrichment of sugar cane by solid state fermentation employing Aspergillus niger was optimized in a packed bed column using a two Factor Central Composit Design {alpha} = 2, considering as independent factors the particle diameter corresponding to different times of grinding for a sample and the air flow rate. It was significative for the air flow rate (optimum 4.34 VKgM) and the particle diameter (optimum 0.136 cm). The average particle size distribution, shape factor, specific surface, volume-surface mean diameter, number of particles, real and apparent density and holloweness for the different times of grinding were determined, in order to characterize the samples. (orig.).

  4. Template assisted solid state electrochemical growth of silver micro- and nanowires

    International Nuclear Information System (INIS)

    Peppler, Klaus; Janek, Juergen

    2007-01-01

    We report on a template based solid state electrochemical method for fabricating silver nanowires with predefined diameter, depending only on the pore diameter of the template. As templates we used porous silicon with pore diameters in the μm range and porous alumina with pore diameters in the nm range. The template pores were filled with silver sulfide (a mixed silver cation and electronic conductor) by direct chemical reaction of silver and sulfur. The filled template was then placed between a silver foil as anode (bottom side) and a microelectrode (top side) as cathode. An array of small cylindrical transference cells with diameters in the range of either micro- or nanometers was thus obtained. By applying a cathodic voltage to the microelectrode silver in the form of either micro- or nanowires was deposited at about 150 deg. C. The growth rate is controllable by the electric current

  5. Up and down translocation events and electric double-layer formation inside solid-state nanopores.

    Science.gov (United States)

    Zanjani, Mehdi B; Engelke, Rebecca E; Lukes, Jennifer R; Meunier, Vincent; Drndić, Marija

    2015-08-01

    We present a theoretical study of nanorod translocation events through solid-state nanopores of different sizes which result in positive or negative ion conductance changes. Using theoretical models, we show that positive conductance changes or up events happen for nanopore diameters smaller than a transition diameter dt, and negative conductance changes or down events occur for nanopore diameters larger than dt. We investigate the underlying physics of such translocation phenomena and describe the significance of the electric double-layer effects for nanopores with small diameters. Furthermore, for nanopores with large diameters, it is shown that a geometric model, formulated based on the nanoparticle blockade inside the nanopore, provides a straightforward and reasonably accurate prediction of ion conductance change. Based on this concept, we also implement a method to distinguish and detect nanorods of different sizes by focusing solely on the sign and not the exact value of the conductance change.

  6. Impact of vent pipe diameter on characteristics of waste degradation in semi-aerobic bioreactor landfill.

    Science.gov (United States)

    Jiang, Guobin; Liu, Dan; Chen, Weiming; Ye, Zhicheng; Liu, Hong; Li, Qibin

    2017-10-01

    The evolution mechanism of a vent pipe diameter on a waste-stabilization process in semi-aerobic bioreactor landfills was analyzed from the organic-matter concentration, biodegradability, spectral characteristics of dissolved organic matter, correlations and principal-component analysis. Waste samples were collected at different distances from the vent pipe and from different landfill layers in semi-aerobic bioreactor landfills with different vent pipe diameters. An increase in vent pipe diameter favored waste degradation. Waste degradation in landfills can be promoted slightly when the vent pipe diameter increases from 25 to 50 mm. It could be promoted significantly when the vent pipe diameter was increased to 75 mm. The vent pipe diameter is important in waste degradation in the middle layer of landfills. The dissolved organic matter in the waste is composed mainly of long-wave humus (humin), short-wave humus (fulvic acid) and tryptophan. The humification levels of the waste that was located at the center of vent pipes with 25-, 50- and 75-mm diameters were 2.2682, 4.0520 and 7.6419 Raman units, respectively. The appropriate vent pipe diameter for semi-aerobic bioreactor landfills with an 800-mm diameter was 75 mm. The effect of different vent pipe diameters on the degree of waste stabilization is reflected by two main components. Component 1 is related mainly to the content of fulvic acid, biologically degradable material and organic matter. Component 2 is related mainly to the content of tryptophan and humin from the higher vascular plants.

  7. Optic Nerve Sheath Diameter Increase on Ascent to High Altitude: Correlation With Acute Mountain Sickness.

    Science.gov (United States)

    Kanaan, Nicholas C; Lipman, Grant S; Constance, Benjamin B; Holck, Peter S; Preuss, James F; Williams, Sarah R

    2015-09-01

    Elevated optic nerve sheath diameter on sonography is known to correlate with increased intracranial pressure and is observed in acute mountain sickness. This study aimed to determine whether optic nerve sheath diameter changes on ascent to high altitude are associated with acute mountain sickness incidence. Eighty-six healthy adults enrolled at 1240 m (4100 ft), drove to 3545 m (11,700 ft) and then hiked to and slept at 3810 m (12,500 ft). Lake Louise Questionnaire scores and optic nerve sheath diameter measurements were taken before, the evening of, and the morning after ascent. The incidence of acute mountain sickness was 55.8%, with a mean Lake Louise Questionnaire score ± SD of 3.81 ± 2.5. The mean maximum optic nerve sheath diameter increased on ascent from 5.58 ± 0.79 to 6.13 ± 0.73 mm, a difference of 0.91 ± 0.55 mm (P = .09). Optic nerve sheath diameter increased at high altitude regardless of acute mountain sickness diagnosis; however, compared to baseline values, we observed a significant increase in diameter only in those with a diagnosis of acute mountain sickness (0.57 ± 0.77 versus 0.21 ± 0.76 mm; P = .04). This change from baseline, or Δ optic nerve sheath diameter, was associated with twice the odds of developing acute mountain sickness (95% confidence interval, 1.08-3.93). The mean optic nerve sheath diameter increased on ascent to high altitude compared to baseline values, but not to a statistically significant degree. The magnitude of the observed Δ optic nerve sheath diameter was positively associated with acute mountain sickness diagnosis. No such significant association was found between acute mountain sickness and diameter elevation above standard cutoff values, limiting the utility of sonography as a diagnostic tool. © 2015 by the American Institute of Ultrasound in Medicine.

  8. Defects in flexoelectric solids

    Science.gov (United States)

    Mao, Sheng; Purohit, Prashant K.

    2015-11-01

    A solid is said to be flexoelectric when it polarizes in proportion to strain gradients. Since strain gradients are large near defects, we expect the flexoelectric effect to be prominent there and decay away at distances much larger than a flexoelectric length scale. Here, we quantify this expectation by computing displacement, stress and polarization fields near defects in flexoelectric solids. For point defects we recover some well known results from strain gradient elasticity and non-local piezoelectric theories, but with different length scales in the final expressions. For edge dislocations we show that the electric potential is a maximum in the vicinity of the dislocation core. We also estimate the polarized line charge density of an edge dislocation in an isotropic flexoelectric solid which is in agreement with some measurements in ice. We perform an asymptotic analysis of the crack tip fields in flexoelectric solids and show that our results share some features from solutions in strain gradient elasticity and piezoelectricity. We also compute the energy release rate for cracks using simple crack face boundary conditions and use them in classical criteria for crack growth to make predictions. Our analysis can serve as a starting point for more sophisticated analytic and computational treatments of defects in flexoelectric solids which are gaining increasing prominence in the field of nanoscience and nanotechnology.

  9. Solid biomass barometer

    International Nuclear Information System (INIS)

    Anon.

    2006-01-01

    The European (EU 25) wish to substitute solid biomass origin energy consumption (principally wood and wood waste, but also straw, crop harvest residues, vegetal and animal waste) for a part of that of fossil fuel origin (petrol, gas and coal) is beginning to pay off. 58,7 million tons oil equivalent (Mtoe) of solid biomass was produced in 2005, i.e. a 3.1 Mtoe increase with respect to 2004. Production of primary energy coming from direct combustion of renewable municipal solid waste in incineration plants should also be added on to this figure. The 0,2 Mtoe increase in this production with respect to 2004 brings valorization of this type of waste up to 5,3 Mtoe in 2005. (author)

  10. Estimating root collar diameter growth for multi-stem western woodland tree species on remeasured forest inventory and analysis plots

    Science.gov (United States)

    Michael T. Thompson; Maggie. Toone

    2012-01-01

    Tree diameter growth models are widely used in many forestry applications, often to predict tree size at a future point in time. Also, there are instances where projections of past diameters are needed. An individual tree model has been developed to estimate diameter growth of multi-stem woodland tree species where the diameter is measured at root collar. The model was...

  11. On solid bulk liquefaction

    OpenAIRE

    Fkhir, Moustafa

    2016-01-01

    Solid bulk cargoes, such as nickel ore and iron ore, have a tendency to liquefy. Such goods can transform from hard to liquid state very rapidly leaving no time for the master or crew to do anything but face their imminent fate. The liquefaction of solid bulk cargoes has claimed many seafarers’ lives and dozens of ships. The moisture content present in these cargoes can be dramatically increased to unsafe limits by the mere reason of the vessel’s rolling on waves. In response to the alarming ...

  12. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  13. Photochemistry on solid surfaces

    CERN Document Server

    Matsuura, T

    1989-01-01

    The latest developments in photochemistry on solid surfaces, i.e. photochemistry in heterogeneous systems, including liquid crystallines, are brought together for the first time in a single volume. Distinguished photochemists from various fields have contributed to the book which covers a number of important applications: molecular photo-devices for super-memory, photochemical vapor deposition to produce thin-layered electronic semiconducting materials, sensitive optical media, the control of photochemical reactions pathways, etc. Photochemistry on solid surfaces is now a major field and this

  14. Solid-state circuits

    CERN Document Server

    Pridham, G J

    2013-01-01

    Solid-State Circuits provides an introduction to the theory and practice underlying solid-state circuits, laying particular emphasis on field effect transistors and integrated circuits. Topics range from construction and characteristics of semiconductor devices to rectification and power supplies, low-frequency amplifiers, sine- and square-wave oscillators, and high-frequency effects and circuits. Black-box equivalent circuits of bipolar transistors, physical equivalent circuits of bipolar transistors, and equivalent circuits of field effect transistors are also covered. This volume is divided

  15. Hybrid elastic solids

    KAUST Repository

    Lai, Yun

    2011-06-26

    Metamaterials can exhibit electromagnetic and elastic characteristics beyond those found in nature. In this work, we present a design of elastic metamaterial that exhibits multiple resonances in its building blocks. Band structure calculations show two negative dispersion bands, of which one supports only compressional waves and thereby blurs the distinction between a fluid and a solid over a finite frequency regime, whereas the other displays super anisotropy-in which compressional waves and shear waves can propagate only along different directions. Such unusual characteristics, well explained by the effective medium theory, have no comparable analogue in conventional solids and may lead to novel applications. © 2011 Macmillan Publishers Limited. All rights reserved.

  16. Solid-State Nanopore

    Directory of Open Access Journals (Sweden)

    Zhishan Yuan

    2018-02-01

    Full Text Available Abstract Solid-state nanopore has captured the attention of many researchers due to its characteristic of nanoscale. Now, different fabrication methods have been reported, which can be summarized into two broad categories: “top-down” etching technology and “bottom-up” shrinkage technology. Ion track etching method, mask etching method chemical solution etching method, and high-energy particle etching and shrinkage method are exhibited in this report. Besides, we also discussed applications of solid-state nanopore fabrication technology in DNA sequencing, protein detection, and energy conversion.

  17. Solid state theory

    CERN Document Server

    Harrison, Walter A

    2011-01-01

    ""A well-written text . . . should find a wide readership, especially among graduate students."" - Dr. J. I. Pankove, RCA.The field of solid state theory, including crystallography, semi-conductor physics, and various applications in chemistry and electrical engineering, is highly relevant to many areas of modern science and industry. Professor Harrison's well-known text offers an excellent one-year graduate course in this active and important area of research. While presenting a broad overview of the fundamental concepts and methods of solid state physics, including the basic quantum theory o

  18. Optical properties of solids

    CERN Document Server

    Wooten, Frederick

    1972-01-01

    Optical Properties of Solids covers the important concepts of intrinsic optical properties and photoelectric emission. The book starts by providing an introduction to the fundamental optical spectra of solids. The text then discusses Maxwell's equations and the dielectric function; absorption and dispersion; and the theory of free-electron metals. The quantum mechanical theory of direct and indirect transitions between bands; the applications of dispersion relations; and the derivation of an expression for the dielectric function in the self-consistent field approximation are also encompassed.

  19. The impact of exercise training on the diameter dilator response to forearm ischaemia in healthy men.

    Science.gov (United States)

    Thijssen, D H J; Tinken, T M; Hopkins, N; Dawson, E A; Cable, N T; Green, D J

    2011-04-01

    Recent studies found differences between groups in the rate of diameter increase following the flow-mediated dilation (FMD). Whilst exercise training alters the magnitude of the FMD, little is known about the impact of exercise training on the rate of diameter increase. The aim of this study is to examine post-cuff deflation changes in brachial artery diameter following 5 min forearm ischaemia every 2 weeks across 8-weeks of a handgrip exercise training regimen. Post-deflation changes in brachial artery diameter following 5-min of ischaemia were examined before, after and every 2-weeks across an 8-week handgrip training programme in healthy young men (n = 11) using echo-Doppler. The magnitude of dilation increased at week 2-4-6, but returned towards baseline values at week 8 (anova: P = 8.001). The time-to-peak diameter (42 ± 15s) demonstrated a significant prolongation at week 4 (77 ± 32s), but returned towards baseline values at weeks 6 and 8 (anova: P < 0.001). The rate of diameter increase did not differ across the intervention. Exercise training in healthy subjects is initially characterized by a larger dilation. Since the rate of dilation did not change, a longer time-to-peak dilation was necessary to achieve the increase in magnitude of dilation. As exercise training continues, the timing and magnitude of the peak diameter response returns to near baseline levels.

  20. Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200 (cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. The UrV150 (cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume. (author)

  1. Effects of implant diameter and prosthesis retention system on the reliability of single crowns.

    Science.gov (United States)

    Bonfante, Estevam A; Almeida, Erika O; Lorenzoni, Fabio C; Coelho, Paulo G

    2015-01-01

    The probability of survival of implant-supported prostheses may be affected by the interplay between different implant diameters supporting screwed or cemented crowns. The purpose of this study was to investigate the effect of implant diameter and prosthesis retention system on the reliability and failure modes of single crowns. Internal-hexagon implants were divided into six groups (n = 21 each) according to implant diameter (3.3, 4.0, or 5.0 mm) and crown retention system (screwed or cemented). Abutments were torqued to the implants, and crowns were then fixed and subjected to step-stress accelerated life testing in water. Use-level probability Weibull curves and reliability for missions of 50,000 cycles at 100, 150, and 200 N were calculated. Failure analysis was performed. Cemented systems presented higher reliability than screwed ones, except between 3.3-mm-diameter cemented and screwed systems at a load of 100 or 150 N. Failure modes were restricted to the abutment screw and varied with implant diameter only in the cement-retained groups. Higher reliability was observed for cement-retained crowns and implants of larger diameter compared to screw-retained and smaller diameter. Failure modes differed between groups.

  2. DETEKSI DIAMETER TUMOR PADA KULIT MENGGUNAKAN SEGMENTASI CITRA BERDASARKAN KARAKTERISTIK ABCDE

    Directory of Open Access Journals (Sweden)

    Wuwanjie Septian

    2016-09-01

    ABSTRAK Kanker kulit merupakan pertumbuhan sel kulit abnormal yang tidak dapat dikendalikan dan pada stadium lanjut dapat mengakibatkan kematian. Menemukan penyakit ini sedini mungkin merupakan salah satu cara untuk menghindari kecacatan maupun kemungkinan terburuk. Karena letaknya dipermukaan kulit, akan mudah bagi siapa saja untuk mengenali sendiri kanker kulit. Deteksi dini kanker kulit dalam bidang dermatologi, dapat dideteksi berdasarkan karakteristik Asymmetrical Shape, Border, Color, Diameter, Evolution (ABCDE. Dalam penelitian ini, deteksi dini difokuskan pada identifikasi diameter pada 30 citra nevus. Metode penelitian berupa pengolahan citra nevus dengan melakukan konversi citra menjadi citra HSI lalu diubah menjadi citra biner, selanjutnya dilakukan tahap segmentasi menggunakan filter median, proses rekonstruksi morfologi dan pada tahap akhir dilakukan deteksi tepi dengan menggunakan operator sobel. Proses deteksi tepi akan mempermudah menghitung nilai luas diameter nevus. Hasil penelitian deteksi dini kanker kulit terhadap 30 citra nevus, diperoleh hasil bahwa metode pengolahan citra yang diusulkan dapat mendeteksi diameter nevus dan berhasil mengidentifikasi citra tersebut sebagai 26 citra memiliki luas diameter nevus yang diidentifikasi sebagai tumor jinak dan 4 citra nevus yang memiliki diameter > 6 mm dan dinyatakan sebagai tumor melanoma. Kata Kunci: Nevus, Melanoma, Segmentasi, Deteksi Diameter

  3. The effect of nozzle diameter, injection pressure and ambient temperature on spray characteristics in diesel engine

    Science.gov (United States)

    Rhaodah Andsaler, Adiba; Khalid, Amir; Sharifhatul Adila Abdullah, Nor; Sapit, Azwan; Jaat, Norrizam

    2017-04-01

    Mixture formation of the ignition process is a key element in the diesel combustion as it influences the combustion process and exhaust emission. Aim of this study is to elucidate the effects of nozzle diameter, injection pressure and ambient temperature to the formation of spray. This study investigated diesel formation spray using Computational Fluid Dynamics. Multiphase volume of fluid (VOF) behaviour in the chamber are determined by means of transient simulation, Eulerian of two phases is used for implementation of mixing fuel and air. The detail behaviour of spray droplet diameter, spray penetration and spray breakup length was visualised using the ANSYS 16.1. This simulation was done in different nozzle diameter 0.12 mm and 0.2 mm performed at the ambient temperature 500 K and 700 K with different injection pressure 40 MPa, 70 MPa and 140 MPa. Results show that high pressure influence droplet diameter become smaller and the penetration length longer with the high injection pressure apply. Smaller nozzle diameter gives a shorter length of the breakup. It is necessary for nozzle diameter and ambient temperature condition to improve the formation of spray. High injection pressure is most effective in improvement of formation spray under higher ambient temperature and smaller nozzle diameter.

  4. Induction Chemotherapy and Continuous Hyperfractionated Accelerated Radiotherapy (CHART) for Patients With Locally Advanced Inoperable Non-Small-Cell Lung Cancer: The MRC INCH Randomized Trial

    International Nuclear Information System (INIS)

    Hatton, Matthew; Nankivell, Matthew; Lyn, Ethan; Falk, Stephen; Pugh, Cheryl; Navani, Neal; Stephens, Richard; Parmar, Mahesh

    2011-01-01

    Purpose: Recent clinical trials and meta-analyses have shown that both CHART (continuous hyperfractionated accelerated radiation therapy) and induction chemotherapy offer a survival advantage over conventional radical radiotherapy for patients with inoperable non-small cell-lung cancer (NSCLC). This multicenter randomized controlled trial (INCH) was set up to assess the value of giving induction chemotherapy before CHART. Methods and Materials: Patients with histologically confirmed, inoperable, Stage I-III NSCLC were randomized to induction chemotherapy (ICT) (three cycles of cisplatin-based chemotherapy followed by CHART) or CHART alone. Results: Forty-six patients were randomized (23 in each treatment arm) from 9 UK centers. As a result of poor accrual, the trial was closed in December 2007. Twenty-eight patients were male, 28 had squamous cell histology, 34 were Stage IIIA or IIIB, and all baseline characteristics were well balanced between the two treatment arms. Seventeen (74%) of the 23 ICT patients completed the three cycles of chemotherapy. All 42 (22 CHART + 20 ICT) patients who received CHART completed the prescribed treatment. Median survival was 17 months in the CHART arm and 25 months in the ICT arm (hazard ratio of 0.60 [95% CI 0.31-1.16], p = 0.127). Grade 3 or 4 adverse events (mainly fatigue, dysphagia, breathlessness, and anorexia) were reported for 13 (57%) CHART and 13 (65%) ICT patients. Conclusions: This small randomized trial indicates that ICT followed by CHART is feasible and well tolerated. Despite closing early because of poor accrual, and so failing to show clear evidence of a survival benefit for the additional chemotherapy, the results suggest that CHART, and ICT before CHART, remain important options for the treatment of inoperable NSCLC and deserve further study.

  5. The impact of baseline diameter on flow-mediated dilation differs in young and older humans.

    Science.gov (United States)

    Thijssen, Dick H J; van Bemmel, Marieke M; Bullens, Lauren M; Dawson, Ellen A; Hopkins, Nicola D; Tinken, Toni M; Black, Mark A; Hopman, Maria T E; Cable, N Timothy; Green, Daniel J

    2008-10-01

    Flow-mediated dilation (FMD) has become a commonly applied approach for the assessment of vascular function and health, but methods used to calculate FMD differ between studies. For example, the baseline diameter used as a benchmark is sometimes assessed before cuff inflation, whereas others use the diameter during cuff inflation. Therefore, we compared the brachial artery diameter before and during cuff inflation and calculated the resulting FMD in healthy children (n=45; 10+/-1 yr), adults (n=31; 28+/-6 yr), and older subjects (n=22; 58+/-5 yr). Brachial artery FMD was examined after 5 min of distal ischemia. Diameter was determined from either 30 s before cuff inflation or from the last 30 s during cuff inflation. Edge detection and wall tracking of high resolution B-mode arterial ultrasound images was used to calculate conduit artery diameter. Brachial artery diameter during cuff inflation was significantly larger than before inflation in children (P=0.02) and adults (P<0.001) but not in older subjects (P=0.59). Accordingly, FMD values significantly differed in children (11.2+/-5.1% vs. 9.4+/-5.2%; P=0.02) and adults (7.3+/-3.2% vs. 4.6+/-3.3%; P<0.001) but not in older subjects (6.3+/-3.4% vs. 6.0+/-4.2%; P=0.77). When the diameter before cuff inflation was used, an age-dependent decline was evident in FMD, whereas FMD calculated using the diameter during inflation was associated with higher FMD values in older than younger adults. In summary, the inflation of the cuff significantly increases brachial artery diameter, which results in a lower FMD response. This effect was found to be age dependent, which emphasizes the importance of using appropriate methodology to calculate the FMD.

  6. Solid bolus swallowing in the radiologic evaluation of dysphagia

    International Nuclear Information System (INIS)

    Westen, D. van; Ekberg, O.

    1993-01-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.)

  7. Diameter-dependent electronic transport properties of Au-catalyst/Ge-nanowire Schottky diodes

    Energy Technology Data Exchange (ETDEWEB)

    Picraux, S Thomas [Los Alamos National Laboratory; Leonard, Francois [SNL; Swartzentruber, Brian S [SNL; Talin, A Alee [SNL

    2008-01-01

    We present electronic transport measurements in individual Au-catalyst/Ge-nanowire interfaces demonstrating the presence of a Schottky barrier. Surprisingly, the small-bias conductance density increases with decreasing diameter. Theoretical calculations suggest that this effect arises because electron-hole recombination in the depletion region is the dominant charge transport mechanism, with a diameter dependence of both the depletion width and the electron-hole recombination time. The recombination time is dominated by surface contributions and depends linearly on the nanowire diameter.

  8. Production of a large diameter ECR plasma with low electron temperature

    International Nuclear Information System (INIS)

    Koga, Mayuko; Hishikawa, Yasuhiro; Tsuchiya, Hayato; Kawai, Yoshinobu

    2006-01-01

    A large diameter plasma over 300 mm in diameter is produced by electron cyclotron resonance (ECR) discharges using a cylindrical vacuum chamber of 400 mm in inner diameter. It is found that the plasma uniformity is improved by adding the nitrogen gas to pure Ar plasma. The electron temperature is decreased by adding the nitrogen gas. It is considered that the electron energy is absorbed in the vibrational energy of nitrogen molecules and the electron temperature decreases. Therefore, the adjunction of the nitrogen gas is considered to be effective for producing uniform and low electron temperature plasma

  9. Diameter-Controllable Magnetic Properties of Co Nanowire Arrays by Pulsed Electrodeposition

    Directory of Open Access Journals (Sweden)

    Youwen Yang

    2010-01-01

    Full Text Available The Co nanowires with different diameters were prepared by pulsed electrodeposition into anodic alumina membranes oxide templates. The micrographs and crystal structures of nanowires were studied by FE-SEM, TEM, and XRD. Due to their cylindrical shape, the nanowires exhibit perpendicular anisotropy. The coercivity and loop squareness (Mr/Ms of Co nanowires depend strongly on the diameter. Both coercivity and Mr/Ms decrease with increasing wire diameter. The behavior of the nanowires is explained briefly in terms of localized magnetization reversal.

  10. Solid biomass barometer 2011

    International Nuclear Information System (INIS)

    2012-01-01

    The winter of 2011 was exceptionally mild, even in Northern Europe, with unusually warm temperatures. As a result the demand for firewood and solid biomass fuel was low. The European Union's primary energy production from solid biomass contracted by 2.9% slipping to 78.8 Mtoe. The first 4 countries are Germany (11.690 Mtoe), France (9.223 Mtoe), Sweden (8.165 Mtoe) and Finland (7.476 Mtoe) and when the production is relative to the population the first 4 countries become: Finland (1.391 toe/inhab.), Sweden (0.867 toe/inhab.), Latvia (0.784 toe/inhab.) and Estonia (0.644 toe/inhab.). Solid biomass electricity production continued to grow, driven by the additional take-up of biomass co-firing, to reach 72.800 TWh at the end of 2011, it means +2.6% compared to 2010. The energy policy of various states concerning solid biomass is analyzed

  11. Solid Oxide Fuel Cell

    DEFF Research Database (Denmark)

    2010-01-01

    The solid oxide fuel cell comprising a metallic support material, an active anode layer consisting of a good hydrocarbon cracking catalyst, an electrolyte layer, an active cathode layer, and a transition layer consisting of preferably a mixture of LSM and a ferrite to the cathode current collector...

  12. Continuous mixing of solids

    NARCIS (Netherlands)

    Raouf, M.S.

    1963-01-01

    The most important literature on theoretical aspects of mixing solids was reviewed.

    Only when the mixed materials showed no segregation it was possible to analyse the mixing process quantitatively. In this case the mixture could be described by the 'χ' Square test. Longitudinal mixing could be

  13. Physical properties of solids

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, M. K.; Young, Jr, F. W.

    1977-10-01

    Research at ORNL into the physical properties of solids is described. Topics covered include: optical, electrical, and magnetic properties of magnesium oxide; ionic conductivity and superconductivity; surface physics and catalysis; defects and impurities in insulating crystals; photovoltaic conversion of solar energy; and fracture studies. (GHT)

  14. Thiokol Solid Rocket Motors

    Science.gov (United States)

    Graves, S. R.

    2000-01-01

    This paper presents viewgraphs on thiokol solid rocket motors. The topics include: 1) Communications; 2) Military and government intelligence; 3) Positioning satellites; 4) Remote sensing; 5) Space burial; 6) Science; 7) Space manufacturing; 8) Advertising; 9) Space rescue space debris management; 10) Space tourism; 11) Space settlements; 12) Hazardous waste disposal; 13) Extraterrestrial resources; 14) Fast package delivery; and 15) Space utilities.

  15. Solid-Waste Management

    Science.gov (United States)

    Science Teacher, 1973

    1973-01-01

    Consists of excerpts from a forthcoming publication of the United States Environmental Protection Agency, Student's Guide to Solid-Waste Management.'' Discusses the sources of wastes from farms, mines, factories, and communities, the job of governments, ways to collect trash, methods of disposal, processing, and suggests possible student action.…

  16. Current Solid Mechanics Research

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    2016-01-01

    About thirty years ago James Lighthill wrote an essay on “What is Mechanics?” With that he also included some examples of the applications of mechanics. While his emphasis was on fluid mechanics, his own research area, he also included examples from research activities in solid mechanics....

  17. alumina solid electrolyte

    Indian Academy of Sciences (India)

    -β/β -alumina; solid electrolyte; calcium impurity; specific resistance. 1. Introduction. Since its development in the 1980s, the Na/S battery has been one of the most promising candidates for energy storage applications. The Na/S battery functions based on the elec- trochemical reaction between sodium and sulphur to form.

  18. alumina solid electrolyte

    Indian Academy of Sciences (India)

    alumina was synthesized using a solid-state reaction. The changes in ... sive, because of its abundant lowcost raw materials and is suitable for high-volume mass production. The battery is composed of a sodium anode, a sulphur cathode, and. Na. +.

  19. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  20. Abdominal Aortic Diameter Is Increased in Males with a Family History of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Mejnert Jørgensen, Trine; Houlind, K; Green, A

    2014-01-01

    OBJECTIVE: To investigate, at a population level, whether a family history of abdominal aortic aneurysm (AAA) is independently related to increased aortic diameter and prevalence of AAA in men, and to elucidate whether the mean aortic diameter and the prevalence of AAA are different between...... participants with male and female relatives with AAA. DESIGN: Observational population-based cross-sectional study. MATERIALS: 18,614 male participants screened for AAA in the VIVA-trial 2008-2011 with information on both family history of AAA and maximal aortic diameter. METHODS: Standardized ultrasound scan...... measurement of maximum antero-posterior aortic diameter. Family history obtained by questionnaire. Multivariate regression analysis was used to test for confounders: age, sex, smoking, comorbidity and medication. RESULTS: From the screened cohort, 569 participants had at least one first degree relative...

  1. Automatic diameter control system applied to the laser heated pedestal growth technique

    Directory of Open Access Journals (Sweden)

    Andreeta M.R.B.

    2003-01-01

    Full Text Available We described an automatic diameter control system (ADC, for the laser heated pedestal growth technique, that reduces the diameter fluctuations in oxide fibers grown from unreacted and non-sinterized pedestals, to less than 2% of the average fiber diameter, and diminishes the average diameter fluctuation, over the entire length of the fiber, to less than 1%. The ADC apparatus is based on an artificial vision system that controls the pulling speed and the height of the molten zone within a precision of 30 mum. We also show that this system can be used for periodic in situ axial doping the fiber. Pure and Cr3+ doped LaAlO3 and pure LiNbO3 were usedas model materials.

  2. LBA-ECO ND-02 Secondary Forest Tree Heights and Diameters, Para, Brazil: 1999-2005

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set provides tree diameters and heights measured from 1999 to 2005 in plots of a secondary-growth forest fertilization experiment located 6.5-km...

  3. LBA-ECO ND-02 Secondary Forest Tree Heights and Diameters, Para, Brazil: 1999-2005

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides tree diameters and heights measured from 1999 to 2005 in plots of a secondary-growth forest fertilization experiment located 6.5-km northwest...

  4. LBA-ECO CD-08 Tree Diameter Measurements, Jacaranda Plots, Manaus, Brazil: 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides diameter at breast height (DBH) measurements made of trees in a dense terra-firme tropical moist forest at the ZF-2 Experimental Station, 90...

  5. LBA-ECO CD-08 Tree Diameter Measurements, Jacaranda Plots, Manaus, Brazil: 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set provides diameter at breast height (DBH) measurements made of trees in a dense terra-firme tropical moist forest at the ZF-2 Experimental...

  6. Pupil Diameter Does Not Correlate with Fixation Duration - or Does It?

    DEFF Research Database (Denmark)

    Lykke Jakobsen, Arnt; Carl, Michael; Elming, Jakob

    2013-01-01

    A number of pupillometric studies have suggested that dynamic differences in pupil diameter correlate with dierent levels of cognitive intensity or excitement. Other studies have suggested a similar correlation between fixation duration and cognitive effort. Since both methodologies for hypothesi...

  7. Simulation on Effect of Preform Diameter in Injection Stretch Blow Molding

    Science.gov (United States)

    Tan, Z. Q.; Rosli, Nurrina; Oktaviandri, Muchamad

    2018-03-01

    Polyethylene terephthalate (PET) is the most common material of resin for manufacturing plastic bottle by injection stretch blow molding due to its excellent properties. As various issues of health and environmental hazards due to the PET use have risen, PET bottle manufacture may be improved by minimizing the wall thickness to reduce the PET use. One of the critical qualifications of the manufacturing process which lead to the wall thickness distribution is the initial preform diameter. In this project, we used the ANSYS Polyflow with aim to evaluate the wall thickness distribution of PET bottle for different diameter of initial preform. As a result, only 4 mm preform diameter presented wall thickness below than 1 mm. On the other hand, at least 6 mm preform diameter can permit the wall thickness 1.3 mm i.e. at the shoulder area.

  8. Diameter-Selective Dispersion of Carbon Nanotubes via Polymers: A Competition between Adsorption and Bundling.

    Science.gov (United States)

    Yang, Hongliu; Bezugly, Viktor; Kunstmann, Jens; Filoramo, Arianna; Cuniberti, Gianaurelio

    2015-09-22

    The mechanism of the selective dispersion of single-walled carbon nanotubes (CNTs) by polyfluorene polymers is studied in this paper. Using extensive molecular dynamics simulations, it is demonstrated that diameter selectivity is the result of a competition between bundling of CNTs and adsorption of polymers on CNT surfaces. The preference for certain diameters corresponds to local minima of the binding energy difference between these two processes. Such minima in the diameter dependence occur due to abrupt changes in the CNT's coverage with polymers, and their calculated positions are in quantitative agreement with preferred diameters reported experimentally. The presented approach defines a theoretical framework for the further understanding and improvement of dispersion/extraction processes.

  9. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  10. Effect of diameter and surface roughness on ultrasonic properties of GaAs nanowires

    Science.gov (United States)

    Dhawan, Punit Kumar; Wan, Meher; Verma, S. K.; Pandey, D. K.; Yadav, R. R.

    2015-02-01

    Second and third order elastic constants of GaAs Nanowires (NWs) are calculated using the many-body interaction potential model. The velocities of ultrasonic waves at different orientations of propagation with unique axis are evaluated using the second order elastic constants. The ultrasonic attenuation and thermal relaxation times of the single crystalline GaAs-NW are determined as a function of diameter and surface roughness by means of Mason theoretical approach using the thermal conductivity and higher order elastic constants. The diameter variation of ultrasonic attenuation and thermal relaxation exhibit second order polynomial function of diameter. It is also found that ultrasonic attenuation and thermal relaxation follow the exponential decay with the surface roughness for GaAs-NW due to reduction in thermal conductivity caused by dominance of surface asperities. Finally, the correlations among ultrasonic parameters, thermal conductivity, surface roughness, and diameter for GaAs-NWs are established leading towards potential applications.

  11. 77 FR 30260 - Welded Large Diameter Line Pipe From Japan: Notice of Rescission of Antidumping Duty...

    Science.gov (United States)

    2012-05-22

    ...; ] DEPARTMENT OF COMMERCE International Trade Administration Welded Large Diameter Line Pipe From Japan: Notice of Rescission of Antidumping Duty Administrative Review AGENCY: Import Administration, International... rules that are applicable to the public. Notices of hearings #0;and investigations, committee meetings...

  12. Synthesis of uniform carbon at silica nanocables and luminescent silica nanotubes with well controlled inner diameters

    International Nuclear Information System (INIS)

    Qian Haisheng; Yu Shuhong; Ren Lei; Yang Yipeng; Zhang Wei

    2006-01-01

    Uniform carbon at silica nanocables and silica nanotubes with well-controlled inner diameters can be synthesized in an easy way by a sacrificial templating method. This was performed using carbon nanofibres as hard templates that were synthesized previously by a hydrothermal carbonization process. Silica nanotubes with well-controlled inner diameters were synthesized from carbon at silica core-shell nanostructures by removal of the core carbon component. The inner diameters of the as-prepared silica nanotubes can be well controlled from several nanometres to hundreds of nanometres by adjusting the diameters of the carbon nanofibres. The silica nanotubes synthesized by this method display strong photoluminescence in ultraviolet at room temperature. Such uniform silica nanotubes might find potential applications in many fields such as encapsulation, catalysis, chemical/biological separation, and sensing

  13. Speedy fabrication of diameter-controlled Ag nanowires using glycerolunder microwave irradiation conditions

    Science.gov (United States)

    Diameter-controlled Ag nanowires were rapidly fabricated (1 min) using inexpensive, abundant, and environmentally-friendly glycerol as both reductant and solvent under non-stirred microwave irradiation conditions; no Ag particles were formed using conventional heating methods. Th...

  14. Relationship between retinal vessel diameters and retinopathy in the Inter99 Eye Study

    DEFF Research Database (Denmark)

    Drobnjak, Dragana; Munch, Inger Christine; Glümer, Charlotte

    2017-01-01

    was 6.3 µm (CI 95%: 1.0 to 11.6, p = 0.020) wider and CRVE was 7.9 µm (CI 95%: 0.7 to 15.2, p = 0.030) wider in those with retinopathy compared to those without retinopathy, after adjusting for age, gender, HbA1c, blood pressure, smoking, serum total and HDL cholesterol. In all participants, CRAE...... of one or more retinal hemorrhages or one or more microaneurysms. Vessel diameters were expressed as central retinal artery equivalent diameter (CRAE) and central retinal vein equivalent diameter (CRVE). Multiple linear regression analyses were performed. RESULTS: Among participants with diabetes, CRAE...... increased with presence of retinopathy (p = 0.005) and with smoking (p = 0.001), and CRAE decreased with hypertension (p vein equivalent diameter increased with presence of retinopathy (p = 0.022) and with smoking (p

  15. Is there a relationship between the diameter of the inferior vena cava ...

    African Journals Online (AJOL)

    2015-04-12

    sectional study was performed included patients aged ≥ 18 years with an unstable haemodynamic and/or respiratory status who were referred to the ED for non-traumatic issues. IVC diameters were measured by ultrasound ...

  16. Luminescence and the solid state

    CERN Document Server

    Ropp, Richard C

    2013-01-01

    Since the discovery of the transistor in 1948, the study of the solid state has been burgeoning. Recently, cold fusion and the ceramic superconductor have given cause for excitement. There are two approaches possible to this area of science, namely, that of solid state physics and solid state chemistry, although both overlap extensively. The former is more concerned with electronic states in solids (including electromagnetics) whereas the latter is more concerned with interactions of atoms in solids. The area of solid state physics is well documented, however, there are very few texts which de

  17. SolidWorks Administration Bible

    CERN Document Server

    Lombard, Matt

    2009-01-01

    What you need to prepare, install, and maintain SolidWorks. It's not enough to know how to use SolidWorks, if your job also requires you to install or maintain it, train new users, and implement standards. This in-depth guide was written for those of you who have to actually manage your company's SolidWorks system. From hardware selection to helping users to licensing and more, this is the everyday, bread-and-butter SolidWorks administration resource that IT and CAD managers have been seeking.:; SolidWorks is a powerful 3D solid modeling system that is popular with CAD users everywhere, but of

  18. Change of pulmonary arterial and bronchial diameter during respiration : HRCT findings

    International Nuclear Information System (INIS)

    Yang, Sang Kyu; Kwak, Byung Kook; Kim, Young Min; Jung, Gul Ho; Lee, Shin Hyung; Lee, Chang Joon; Song, Chi Ho

    1997-01-01

    To evaluate the changes and normal ranges of the artery-bronchus ratio(ABR) during respiration We analyzed HRCT of 10 healthy adults. The HRCT findings of ten healthy adults were analysed. CT scanning was performed with 1mm collimation at 3mm intervals during full inspiration and full expiration, with a range during inspiration from 2cm to 4cm above the carina and from 4cm above to 2cm below the right hemidiaphragm. The range during expiration was from 1cm to 3cm above the carina and from 4cm above to 2cm below the right hemidiaphragm. ABiR (defined as the diameter of pulmonary artery divided by the inner diameter of the bronchus), ABoR (defined as the diameter of pulmonary artery divided by the outer diameter of the bronchus) and BLR (defined as the inner diameter of the bronchus divided by the outer diameter of the bronchus) were measured on the display console. The mean inner diameter of the bronchi was 2.04±0.73mm during inspiration and 1.68±0.51mm during expiration, while the mean diameter of the arteries was 3.95±1.03mm during inspiration and 4.37±1.09mm during expiration. The diameters of the bronchi were thus seen to increase during inspiration, and the diameters of the pulmonary arteries, to decrease. The mean thickness of the bronchial wall was 1.07±0.19mm during inspiration and 1.06±0.24mm during expiration;thus, no change in thickness was seen during respiration (p<0.05). Mean ABiR was 2.01±0.60 (range 1.15-4.58) during inspiration and 2.59±0.74(range 1.16-4.9) during expiration, and in all cases the inner diameter of the bronchus was less than that of the accompanying pulmonary artery. Mean ABoR was 0.91±0.19 during inspiration and 1.09±0.22 during expiration. While for BLR, the corresponding fingures were 0.46±0.06, and 0.44±0.09. HRCT is a useful tool for evaluating changes in the pulmonary arteries and bronchi during respiration

  19. Development of a 1.0 mm inside diameter temperature-assisted focusing precolumn for use with 2.1 mm inside diameter columns.

    Science.gov (United States)

    Groskreutz, Stephen R; Horner, Anthony R; Weber, Stephen G

    2017-11-10

    On-column solute focusing is a simple and powerful method to decrease the influence of precolumn band spreading and increase the allowable volume injected increasing sensitivity. It relies on creating conditions so that the retention factor, k', is transiently increased during the injection process. Both solvent composition and temperature control can be used to effect solute focusing. In the case of temperature, the release of the transiently delayed solute band requires increasing the temperature rapidly and with a minimum of radial thermal gradients. Thus, the focus of attention in temperature-based efforts to carry out on-column focusing has been on capillary columns. As a result, the benefits of this simple and reliable approach, temperature-assisted solute focusing or TASF, are not available to those using larger diameter columns, in particular the highly successful 2.1mm inside diameter columns. Based on considerations of thermal entrance length at the volume flow rates used with 2.1mm inside diameter columns, TASF would not be effective with such columns. However, we determined that the thermal entrance length for a 1.0mm inside diameter precolumn is sufficiently short, about 2mm, that it could work as a precolumn before a 2.1mm inside diameter analytical column. Finite element calculations demonstrate that a 1.0×20mm precolumn packed with 5μm reversed phase particles is effective at a flow rate of 250μL/min, suitable for the 2.1mm inside diameter column. Eight 1-cm 2 Peltier devices are used to heat (and cool) the precolumn. The computed axial temperature profile shows that the center of the column heats more rapidly than the ends. Based on the changes in back pressure, the full temperature transient from 5°C (focus) to 80°C (release) takes about 10s. Experimental van Deemter curves indicate that the reduced velocity in the precolumn at 250μL/min flow rate is about 50. Nonetheless, about 1000 theoretical plates are generated. When operating as a

  20. Economic feasibility of products from inland west small-diameter timber. Forest Service general technical report

    Energy Technology Data Exchange (ETDEWEB)

    Spelter, H.; Wang, R.; Ince, P.

    1996-05-01

    A large part of the forests located in the Rocky Mountain region of the U.S. West (inland West) is characterized by densely packed, small-diameter stands. The purpose of this study was to examine the economic feasibility of using small-diameter material from this resource to manufacture various wood products: oriented strandboard (OSB), stud lumber, random-length dimension lumber, machine-stress-rated random-length lumber, laminated veneer lumber (LVL), and market pulp.

  1. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2013-08-15

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  2. SAGITTAL DIAMETER OF FORAMEN MAGNUM IN NORMAL POPULATION: AN MRI STUDY

    OpenAIRE

    Lakshmi

    2015-01-01

    Lower position of cerebellar tonsils was frequently noticed in Western studies. In some of the studies, sagittal diameter of foramen magnum was found to be larger in cases of Chiari malformation. However, there are no Indian studies for comparison. Our study was proposed to determine the standard values for sagittal diameter of foramen magnum in various age groups and both sexes. This gives a guideline for further studies in pathological conditions like Craniovertebral Junctional ...

  3. A new method to optimize root order classification based on the diameter interval of fine root

    OpenAIRE

    Liu, Ying; Wang, Guoliang; Yu, Kunxia; Li, Peng; Xiao, Lie; Liu, Guobin

    2018-01-01

    Plant roots are a highly heterogeneous and hierarchical system. Although the root-order method is superior to the root diameter method for revealing differences in the morphology and physiology of fine roots, its complex partitioning limits its application. Whether root order can be determined by partitioning the main root based on its diameter remains uncertain. Four methods were employed for studying the morphological characteristics of seedling roots of two Pinus species in a natural and n...

  4. A quick method to determine root biomass distribution in diameter classes

    OpenAIRE

    Blouin, Manuel; Barot, Sébastien; Roumet, C.

    2007-01-01

    Describing root biomass distribution in diameter classes is a fundamental way to understand the relation between a plant and its surrounding soil. Current methods used for its measurement are not well adapted to large root systems. A new quick method is proposed for the measurement of diameter distribution in large root systems. It is based on the one used in pedology to assess soil granulometry. Roots are dried, cut in a mixer and placed on a sieve column; biomass distribution according to r...

  5. Film behaviour of vertical gas-liquid flow in a large diameter pipe

    OpenAIRE

    Zangana, Mohammed Haseeb Sedeeq

    2011-01-01

    Gas-liquid flow commonly occurs in oil and gas production and processing system. Large diameter vertical pipes can reduce pressure drops and so minimize operating costs. However, there is a need for research on two-phase flow in large diameter pipes to provide confidence to designers of equipments such as deep water risers. In this study a number of experimental campaigns were carried out to measure pressure drop, liquid film thickness and wall shear in 127mm vertical pipe. Total pressur...

  6. Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.

    Science.gov (United States)

    Arlen, Angela M; Leong, Traci; Guidos, P Joseph; Alexander, Siobhan E; Cooper, Christopher S

    2017-12-01

    Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. STUDY OF VARIATION OF THE DIAMETER OF THE SPINAL CANAL AND THE FORAMINA IN SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Enguer Beraldo Garcia

    2016-03-01

    Full Text Available ABSTRACT Objective: To define and quantify the degree of change of the spinal canal diameter in patients with degenerative and spondylolytic spondylolisthesis. Methods: We studied CT scans of 54 patients. Of this total, 37 (29 women and 8 men had degenerative type and 17 (7 women and 10 men had spondylolytic type. Results: In the degenerative spondylolisthesis group, the average diameter of the spinal canal at the injured vertebra level was 17.35 mm and 17.64 mm for the upper vertebra level. The average diameter of the foramen at the level of the affected vertebra was 14.61 mm to left side and 15.00 mm to the right side. The average diameter of the foramen at the upper vertebra level was 16.82 mm to the left side and 16.51 mm to the right side. In the spondylolytic group, the average diameter of the spinal canal at the level of the affected vertebra was 23.25 mm and at the upper vertebra level was 18.66 mm. The average diameter of the foramen at the level of the affected vertebra was 11.98 mm to the left side and 12.34 mm to the right side. The average diameter of the foramen at the level of the upper vertebra was 16.97 mm to the left side and 15.58 mm to the right side. Conclusion: The diameter of the spinal canal in the sagittal plane showed no statistically significant increase in the spondylolytic spondylolisthesis group, in contrast to what is found in the degenerative spondylolisthesis group. It was also observed a reduction in vertebral foramina of the injured level in both groups.

  8. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography

    International Nuclear Information System (INIS)

    Lucarelli, Claudio Luiz

    1995-01-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  9. Spontaneous high frequency diameter oscillations of larger retinal arterioles are reduced in type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Bek, Toke; Jeppesen, Peter; Kanters, Jørgen K.

    2013-01-01

    Diabetic retinopathy is characterized by morphological changes in the retina secondary to disturbances in retinal blood flow. Vasomotion is a mechanism for regulating blood flow by spontaneous oscillations in the diameter of retinal resistance arterioles, and has been shown to be disturbed outside...... the eye in diabetic patients. Therefore, the purpose of the present study was to characterize spontaneous oscillations in the diameter of retinal arterioles in normal persons and in persons with different severity of diabetic retinopathy....

  10. A combination of permanent magnet and magnetic coil for a large diameter ion source

    International Nuclear Information System (INIS)

    Uramoto, Joshin; Kubota, Yusuke; Miyahara, Akira.

    1980-02-01

    A large diameter ion source for fast neutral beam injection is designed under a magnetic field (we call ''Uramoto Field'') composed of a circular ferrite permanent magnet and a usual coreless magnetic coil. As the magnetic filed is reduced abruptly in a discharge anode, an ion source with a uniform ion current density over a large diameter is produced easily without a ''button'' of ORNL duoPIGatron type ion source (a floating electrode to diffuse an axial plasma flow radially). (author)

  11. Editorial Commentary: Size Does Matter-Anterior Cruciate Ligament Graft Diameter Affects Biomechanical and Clinical Outcomes.

    Science.gov (United States)

    Steiner, Mark

    2017-05-01

    Anterior cruciate ligament (ACL) graft strength is related to graft diameter and how ACL grafts heal. All grafts appear to lose strength during healing. Clinical studies have documented that hamstring grafts less than 8 mm wide are more vulnerable to failure. Tripling the semitendinosus allows to increase the graft diameter and strength. A recent study documents a semitendinosus tripling technique with excellent clinical results. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Estimation of vessel diameter and blood flow dynamics from laser speckle images

    DEFF Research Database (Denmark)

    Postnov, Dmitry D.; Tuchin, Valery V.; Sosnovtseva, Olga

    2016-01-01

    Laser speckle imaging is a rapidly developing method to study changes of blood velocity in the vascular networks. However, to assess blood flow and vascular responses it is crucial to measure vessel diameter in addition to blood velocity dynamics. We suggest an algorithm that allows for dynamical...... masking of a vessel position and measurements of it's diameter from laser speckle images. This approach demonstrates high reliability and stability....

  13. Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

    International Nuclear Information System (INIS)

    Simon, R.S.; Mozurkewich, D.; Johnston, K.J.; Gaume, R.; Hutter, D.J.; Bowers, P.F.; Colavita, M.M.; Shao, M.

    1990-01-01

    Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm. 10 refs

  14. METHODS OF CONTROLLING THE AVERAGE DIAMETER OF THE THREAD WITH ASYMMETRICAL PROFILE

    Directory of Open Access Journals (Sweden)

    L. M. Aliomarov

    2015-01-01

    Full Text Available To handle the threaded holes in hard materials made of marine machinery, operating at high temperatures, heavy loads and in aggressive environments, the authors have developed the combined tool core drill -tap with a special cutting scheme, which has an asymmetric thread profile on the tap part. In order to control the average diameter of the thread of tap part of the combined tool was used the method three wires, which allows to make continuous measurement of the average diameter of the thread along the entire profile. Deviation from the average diameter from the sample is registered by inductive sensor and is recorded by the recorder. In the work are developed and presented control schemes of the average diameter of the threads with a symmetrical and asymmetrical profile. On the basis of these schemes are derived formulas for calculating the theoretical option to set the wires in the thread profile in the process of measuring the average diameter. Conducted complex research and the introduction of the combined instrument core drill-tap in the production of products of marine engineering, shipbuilding, ship repair power plants made of hard materials showed a high efficiency of the proposed technology for the processing of high-quality small-diameter threaded holes that meet modern requirements.

  15. Film boiling heat transfer from relatively large diameter downward-facing hemispheres

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Soo; Suh, Kune Y.; Park, Goon Cherl; Lee, Un Chul [Seoul National Univ., Seoul (Korea, Republic of); Yoon, Ho Jun [Purdue Univ., Indiana (United States)

    2003-08-01

    Film boiling heat transfer coefficients for a downward-facing hemispherical surface are measured from the quenching tests in DELTA (Downward-boiling Experimental Loop for Transient Analysis). Two test sections are made of copper to maintain Bi below 0.1. The outer diameters of the hemispheres are 120 mm and 294 mm, respectively. The thickness of both the test sections is 30 mm. The effect of diameter on film boiling heat transfer is quantified utilizing results obtained from the two test sections. The measured heat transfer coefficients for the test section with diameter 120 mm lie within the bounding values from the laminar film boiling analysis, while those for diameter 294 mm are found to be greater than the numerical results on account of the Helmholtz instability. There is little difference observed between the film boiling heat transfer coefficients measured from the two test sections. In addition, the higher thermal conductivity of copper results in the higher minimum heat flux in the tests. For the test section of diameter 120 mm, the Leidenfrost point is lower than that for the test section of diameter 294 mm. Destabilization of film boiling propagates radially inward for the 294 mm test section versus radially outward for the 120 mm test section.

  16. Pitfalls in Root Trait Calculations: How Ignoring Diameter Heterogeneity Can Lead to Overestimation of Functional Traits.

    Science.gov (United States)

    Rose, Laura

    2017-01-01

    Specific root length (SRL) and root tissue density (RTD) are ecologically functional traits which are calculated from root length or volume and root dry weight. Both can be converted into each other using the root diameter assuming roots are cylindrical. The calculation of volume from length or length from volume is, however, problematic because samples of roots do usually not have a constant diameter. Ignorance of the diameter heterogeneity leads to an overestimation of length and an underestimation of volume if standard formulas are used. Here I show for two datasets that SRL and RTD are overestimated on average 67% for the two analyzed datasets, but up to 150%, if calculated from each other. I further highlight that the volume values for the total sample as provided by the commonly used software WinRHIZO TM should only be used for objects with constant diameter. I recommend to use volume values provided for each diameter class of a sample if WinRHIZO TM is used. If manual methods, like the line-intersect method, are used, roots should be separated into diameter classes before length measurements if the volume is calculated from length. Trait to trait conversions for whole samples are not recommended.

  17. A new method to optimize root order classification based on the diameter interval of fine root.

    Science.gov (United States)

    Liu, Ying; Wang, Guoliang; Yu, Kunxia; Li, Peng; Xiao, Lie; Liu, Guobin

    2018-02-13

    Plant roots are a highly heterogeneous and hierarchical system. Although the root-order method is superior to the root diameter method for revealing differences in the morphology and physiology of fine roots, its complex partitioning limits its application. Whether root order can be determined by partitioning the main root based on its diameter remains uncertain. Four methods were employed for studying the morphological characteristics of seedling roots of two Pinus species in a natural and nitrogen-enriched environment. The intrinsic relationships among categories of roots by root order and diameter were systematically compared to explore the possibility of using the latter to describe root morphology. The normal transformation method proved superior to the other three in that the diameter intervals corresponded most closely (at least 68.3%) to the morphological characteristics. The applied methods clearly distinguished the results from the natural and nitrogen-rich environments. Considering both root diameter and order simplified the classification of fine roots, and improved the estimation of root lifespan and the data integrity of field collection, but failed to partition all roots into uniform diameter intervals.

  18. Prediction of bubble detachment diameter in flow boiling based on force analysis

    International Nuclear Information System (INIS)

    Chen Deqi; Pan Liangming; Ren Song

    2012-01-01

    Highlights: ► All the forces acting on the growing bubbles are taken into account in the model. ► The bubble contact diameter has significant effect on bubble detachment. ► Bubble growth force and surface tension are more significant in narrow channel. ► A good agreement between the predicted and the measured results is achieved. - Abstract: Bubble detachment diameter is one of the key parameters in the study of bubble dynamics and boiling heat transfer, and it is hard to be measured in a boiling system. In order to predict the bubble detachment diameter, a theoretical model is proposed based on forces analysis in this paper. All the forces acting on a bubble are taken into account to establish a model for different flow boiling configurations, including narrow and conventional channels, upward, downward and horizontal flows. A correlation of bubble contact circle diameter is adopted in this study, and it is found that the bubble contact circle diameter has significant effect on bubble detachment. A new correlation taking the bubble contact circle diameter into account for the evaluation of bubble growth force is proposed in this study, and it is found that the bubble growth force and surface tension force are more significant in narrow channel when comparing with that in conventional channel. A visual experiment was carried out in order to verify present model; and the experimental data from published literature are used also. A good agreement between predicted and measured results is achieved.

  19. Relationship between the tensile strengths and diameters of human umbilical cords.

    Science.gov (United States)

    Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H

    2018-03-06

    Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  20. Morphology of living cells cultured on nanowire arrays with varying nanowire densities and diameters.

    Science.gov (United States)

    Li, Zhen; Persson, Henrik; Adolfsson, Karl; Oredsson, Stina; Prinz, Christelle N

    2018-04-02

    Vertical nanowire arrays are increasingly investigated for their applications in steering cell behavior. The geometry of the array is an important parameter, which influences the morphology and adhesion of cells. Here, we investigate the effects of array geometry on the morphology of MCF7 cancer cells and MCF10A normal-like epithelial cells. Different gallium phosphide nanowire array-geometries were produced by varying the nanowire density and diameter. Our results show that the cell size is smaller on nanowires compared to flat gallium phosphide. The cell area decreases with increasing the nanowire density on the substrate. We observed an effect of the nanowire diameter on MCF10A cells, with a decreased cell area on 40 nm diameter nanowires, compared to 60 and 80 nm diameter nanowires in high-density arrays. The focal adhesion morphology depends on the extent to which cells are contacting the substrate. For low nanowire densities and diameters, cells are lying on the substrate and we observed large focal adhesions at the cell edges. In contrast, for high nanowire densities and diameters, cells are lying on top of the nanowires and we observed point-like focal adhesions distributed over the whole cell. Our results constitute a step towards the ability to fine-tune cell behavior on nanowire arrays.