WorldWideScience

Sample records for inch acrylic column

  1. Poly[hydroxyethyl acrylate-co-poly(ethylene glycol) diacrylate] monolithic column for efficient hydrophobic interaction chromatography of proteins.

    Science.gov (United States)

    Li, Yuanyuan; Tolley, H Dennis; Lee, Milton L

    2009-11-15

    Rigid poly[hydroxyethyl acrylate-co-poly(ethylene glycol) diacrylate] monoliths were synthesized inside 75 mum i.d. capillaries by one-step UV-initiated copolymerization using methanol and ethyl ether as porogens. The optimized monolithic column was evaluated for hydrophobic interaction chromatography (HIC) of standard proteins. Six proteins were separated within 20 min with high resolution using a 20 min elution gradient, resulting in a peak capacity of 54. The effect of gradient rate and initial salt concentration on the retention of proteins were investigated. Mass recovery was found to be greater than 96%, indicating the biocompatibility of this monolith. The monolith was mechanically stable and showed nearly no swelling or shrinking in different polarity solvents. The preparation of this in situ polymerized acrylate monolithic column was highly reproducible. The run-to-run and column-to-column reproducibilities were less than 2.0% relative standard deviation (RSD) on the basis of the retention times of protein standards. The performance of this monolithic column for HIC was comparable or superior to the performance of columns packed with small particles.

  2. Dipentaerythritol penta-/hexa-acrylate based-highly cross-linked hybrid monolithic column: Preparation and its applications for ultrahigh efficiency separation of proteins.

    Science.gov (United States)

    Ma, Junqian; Dai, Qian; Li, Xueyun; Zhu, Xianghui; Ma, Teng; Qiao, Xiaoqiang; Shen, Shigang; Liu, Xiuhua

    2017-04-22

    In this study, multi-acrylate based dipentaerythritol penta-/hexa-acrylate (DPEPA) was exploited for fabrication of highly cross-linked hybrid monolithic column by copolymerization with polyhedral oligomeric silsesquioxane methacryl substituted (POSS-MA) via a "one-pot" method. The new DPEPA-POSS hybrid monolithic column was respectively characterized by Fourier transform infrared spectrometry, thermogravimetric analysis, scanning electron microscopy and nitrogen adsorption/desorption measurement. When it was used for the separation of amides, thioureas and positional isomers of phenols, ultrahigh column efficiency separation (up to 511,000 N m -1 ) was achieved with excellent selectivity. Moreover, intact protein standards could be efficiently separated with minimum tailing peaks, outperforming the commercially available silica-based C8 column. Furthermore, successful separation of complex egg white proteins and expressed BARD1 BRCT domains protein sample was also achieved with good chromatographic performance. In the future work, the DPEPA-POSS hybrid monolithic column will be further exploited and applied in capillary electrochromatography as well as the top-down based proteome research. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Acrylic composition

    International Nuclear Information System (INIS)

    Kimura, Tadashi; Ozeki, Takao; Kobayashi, Juichi; Nakamoto, Hideo; Meda, Yutaka.

    1969-01-01

    An acrylic composition and a process for the production of an easily hardenable coating material by irradiating with active energy, particularly electron beams and ultraviolet light, are provided using a mixture of 10%-100% by weight of an unsaturated compound and 90%-0% of a vinyl monomer. The composition has a high degree of polymerization, low volatility, low viscosity and other properties similar to thermosetting acrylic or amino alkyd resins. The aforesaid unsaturated compound is produced by primarily reacting saturated cyclocarboxylic anhydride and/or alpha-, beta-ethylene unsaturated carboxylic anhydride and by secondarily reacting an epoxy radical-containing vinyl monomer by addition reaction with polyhydric alcohols. Each reaction is conducted in the presence of a tertiary amino radical-containing vinyl monomer as a catalyst. The cross-linking is effected generally with an electron beam accelerator of 0.1-2.0 MeV or with a light beam in the 2,000-8,000A range in the presence of a photosensitive agent. In one example, 62 parts of ethylene glycol and 196 parts of maleic anhydride were dissolved in a mixture consisting of 100 parts of n-butyl methacrylate and 30 parts of styrene. To the mixture were added 5 parts of 2-methyl 5 vinyl piridine and 0.005 part of hydroquinone monomethyl ether. After the reaction at 90 0 C for 3 hours, a compound HOC:O-CH=CHC:OCH 2 CH 2 C:OOH was produced. To this solution were added 285 parts of glycidyl methacrylate. After the reaction at 90 0 C for 6 hours, 95% of the carboxylic acids reacted with epoxy radicals. Fourteen examples are given. (Iwakiri, K.)

  4. 8-inch IBM floppy disk

    CERN Multimedia

    1971-01-01

    The 8-inch floppy disk was a magnetic storage disk for the data introduced commercially by IBM in 1971. It was designed by an IBM team as an inexpensive way to load data into the IBM System / 370. Plus it was a read-only bare disk containing 80 KB of data. The first read-write version was introduced in 1972 by Memorex and could contain 175 KB on 50 tracks (with 8 sectors per track). Other improvements have led to various coatings and increased capacities. Finally, it was surpassed by the mini diskette of 5.25 inches introduced in 1976.

  5. Synthesis of acrylic prepolymer

    International Nuclear Information System (INIS)

    Hussin bin Mohd Nor; Dahlan bin Haji Mohd; Mohamad Hilmi bin Mahmood.

    1988-04-01

    An acrylic prepolymer was synthesized from glycidyl methacrylate (GMA), butyl methacrylate (BMA), methyl methacrylate (MMA) and acrylic acid (AA). Butyl acetate (BAc), benzoyl peroxide (BzO), 4-methoxyphenol (MPh) and triethylamine (TEA) were used as solvent, initiator, inhibitor and catalyst respectively. Observations of the synthesis leading to the formation of acrylic prepolymer are described. (author)

  6. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  7. Ten inch Planar Optic Display

    Energy Technology Data Exchange (ETDEWEB)

    Beiser, L. [Beiser (Leo) Inc., Flushing, NY (United States); Veligdan, J. [Brookhaven National Lab., Upton, NY (United States)

    1996-04-01

    A Planar Optic Display (POD) is being built and tested for suitability as a high brightness replacement for the cathode ray tube, (CRT). The POD display technology utilizes a laminated optical waveguide structure which allows a projection type of display to be constructed in a thin (I to 2 inch) housing. Inherent in the optical waveguide is a black cladding matrix which gives the display a black appearance leading to very high contrast. A Digital Micromirror Device, (DMD) from Texas Instruments is used to create video images in conjunction with a 100 milliwatt green solid state laser. An anamorphic optical system is used to inject light into the POD to form a stigmatic image. In addition to the design of the POD screen, we discuss: image formation, image projection, and optical design constraints.

  8. 10-inch planar optic display

    Science.gov (United States)

    Beiser, Leo; Veligdan, James T.

    1996-05-01

    A planar optic display (POD) is being built and tested for suitability as a high brightness replacement for the cathode ray tube, (CRT). The POD display technology utilizes a laminated optical waveguide structure which allows a projection type of display to be constructed in a thin (1 to 2 inch) housing. Inherent in the optical waveguide is a black cladding matrix which gives the display a black appearance leading to very high contrast. A digital micromirror device, (DMD) from Texas Instruments is used to create video images in conjunction with a 100 milliwatt green solid state laser. An anamorphic optical system is used to inject light into the POD to form a stigmatic image. In addition to the design of the POD screen, we discuss: image formation, image projection, and optical design constraints.

  9. Acrylic purification and coatings

    International Nuclear Information System (INIS)

    Kuzniak, Marcin

    2011-01-01

    Radon (Rn) and its decay daughters are a well-known source of background in direct WIMP detection experiments, as either a Rn decay daughter or an alpha particle emitted from a thin inner surface layer of a detector could produce a WIMP-like signal. Different surface treatment and cleaning techniques have been employed in the past to remove this type of contamination. A new method of dealing with the problem has been proposed and used for a prototype acrylic DEAP-1 detector. Inner surfaces of the detector were coated with a layer of ultra pure acrylic, meant to shield the active volume from alphas and recoiling nuclei. An acrylic purification technique and two coating techniques are described: a solvent-borne (tested on DEAP-1) and solvent-less (being developed for the full scale DEAP-3600 detector).

  10. Antimicrobial Acrylic Fiber

    Science.gov (United States)

    2006-08-01

    the spinneret fitted with a 325 mesh wire screen filter inside. Extrusion conditions were as follows: 2 Process: dry-jet wet spinning...crude nonwoven fabric (one inch square), treated samples were challenged with Staphylococcus aureus (ATCC 6538) using a modified AATCC Test Method 100...obtained chlorine after chlorination. The fibers were formed into a nonwoven matt which upon chlorination with 10% household bleach became

  11. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  12. Performance evaluation of a rectifier column using gamma column scanning

    Directory of Open Access Journals (Sweden)

    Aquino Denis D.

    2017-12-01

    Full Text Available Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.

  13. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  14. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  15. Bonding auto-polymerising acrylic resin to acrylic denture teeth.

    LENUS (Irish Health Repository)

    Nagle, Susan

    2009-09-01

    This study investigated the effect of surface treatments on the shear bond strength of an auto-polymerising acrylic resin cured to acrylic denture teeth. The surface treatments included a combination of grit-blasting and\\/or wetting the surface with monomer. Samples were prepared and then stored in water prior to shear testing. The results indicated that the application of monomer to the surface prior to bonding did not influence the bond strength. Grit blasting was found to significantly increase the bond strength.

  16. The Six-Inch Lunar Atlas A Pocket Field Guide

    CERN Document Server

    Spain, Don

    2009-01-01

    The Six-Inch Lunar Atlas has been designed specifically for use in the field by lunar observers so it’s perfect for fitting into an observer’s pocket! The author’s own lunar photographs were taken with a 6-inch (150mm) telescope and CCD camera, and closely match the visual appearance of the Moon when viewed through 3-inch to 8-inch telescopes. Each picture is shown oriented "as the Moon really is" when viewed from the northern hemisphere, and is supplemented by exquisite computer sketches that list the main features. Two separate computer sketches are provided to go with each photograph, one oriented to appear as seen through an SCT telescope (e.g. the Meade and Celestron ranges), the other oriented for Newtonian and refracting telescopes. Observers using the various types telescopes will find it extremely helpful to identify lunar features as the human brain is very poor at making "mirror-image" visual translations.

  17. Aerosol Research Branch (ARB) 48 inch Lidar Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARB_48_IN_LIDAR data set contains data collected from a 48-inch lidar system located at NASA Langley Research Center. Each granule consists of one year of data....

  18. 16 CFR 500.19 - Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI...

    Science.gov (United States)

    2010-01-01

    .../pound quantities and inch/pound quantities to SI metric quantities. 500.19 Section 500.19 Commercial... LABELING ACT § 500.19 Conversion of SI metric quantities to inch/pound quantities and inch/pound quantities to SI metric quantities. (a) For calculating the conversion of SI metric quantities to inch/pound...

  19. Development of 52 inches last stage blade for steam turbines

    International Nuclear Information System (INIS)

    Suzuki, Atsuhide; Hisa, Shoichi; Nagao, Shinichiro; Ogata, Hisao

    1986-01-01

    The last stage blades of steam turbines are the important component controlling the power output and performance of plants. In order to realize a unit of large capacity and high efficiency, the proper exhaust area and the last stage blades having good performance are indispensable. Toshiba Corp. has completed the development of the 52 inch last stage blades for 1500 and 1800 rpm steam turbines. The 52 inch last stage blades are the longest in the world, which have the annular exhaust area nearly 1.5 times as much as that of 41 inch blades used for 1100 MW, 1500 rpm turbines in nuclear power stations. By adopting these 52 inch blades, the large capacity nuclear power plants up to 1800 MW can be economically constructed, the rate of heat consumption of 1350 MW plants is improved by 3 ∼ 4 % as compared with 41 inch blades, and in the plants up to 1100 MW, LP turbines can be reduced from three sets to two. The features of 52 inch blades, the flow pattern and blade form design, the structural strength analysis and the erosion withstanding property, and the verification by the rotation test of the actual blades, the performance test using a test turbine, the vibration analysis of the actually loaded blades and the analysis of wet steam behavior are reported. (Kako, I.)

  20. Poly(alkyl acrylate) nonparticles

    International Nuclear Information System (INIS)

    Kreuter, J.

    1985-01-01

    This study deals with the preparation of poly(alkyl acrylic) and poly(alkyl cyanocrylic) nanoparticles. Nonoparticles are solid colloidal particles, consisting of macromolecular materials in which drugs or biologically active materials are dissolved, entrapped, and encapsulated, and/or to which the active substance is adsorbed or attached. Poly(alkyl acrylic) nanoparticles are much more slowly biodegradable than poly(alkyl cyanoacrylate) nanoparticles, and are thus more suitable for drug delivery purposes. Poly(methyl methacrylate) is the material of choice for the use of nanoparticles as an adjuvant for vaccines and are produced by emulsifier-free polymerization in aqueous media. The polymerization, which can be initiated with gamma rays or with potassium peroxodisulfate, is described

  1. Rheology of Polyaniline Dispersions in Acrylic Resin

    OpenAIRE

    PLESU, Nicoleta; LIESCU, Smaranda; ILIA, Gheorghe

    2006-01-01

    Acrylic dispersions based on polyaniline were obtained and characterised. The polyaniline was obtained by chemical polymerisation of aniline in different organic acid containing phosphorous, in the presence of ammonium-peroxidisulphate as oxidant agent. The blends were obtained by mechanical dispersion of polyaniline in commercially available acrylic resin. The flow behaviour of these dispersions at different shear rates was studied. Furthermore, the resulting acrylic dispersions w...

  2. Radiation curing applications of palm oil acrylates

    International Nuclear Information System (INIS)

    Mohd Hilmi Mahmood; Khairul Zaman; Rida, Anak Tajau; Mek Zah Salleh; Rosley Che Ismail

    2007-01-01

    Various palm oil based urethan acrylate prepolymers (UP) were prepared from palm oil based polyols, diisocyanate compounds and hydroxyl terminated acrylate monomers by following procedure derived from established methods. The products were compared with each other in term of their molecular weights (MW), viscosities, curing speed by UV irradiation, gel contents and film hardness. The molecular structure of diisocyanate compounds and hydroxyl acrylate monomers were tend to determine the molecular weights and hence viscosities of the final products of urethan acrylate prepolymers (UP), whereas, the MW of the UP has no direct effects on the UV curing properties of the prepolymers. (author)

  3. Corrosion-Resistant Acrylic Coatings

    Science.gov (United States)

    1992-03-31

    ester solvents include ethylene glycol acceptable for anti-corrosive compositions. Blistering in monoethyl ether acetate, diethylene glycol monoethyl ...corrosion and 0 is i inch or more methyl isobutyl ketone. diethyl ketone, and cyclohexa- creepage from the scribe. Ratings of 3 or above are none. Glycol ...45 * coating is determined in accordance with ASTM ether acetate, etc. D714-56. This method describes blister size as numbers The coating has

  4. Concretes reinforced with acrylic fibres

    Directory of Open Access Journals (Sweden)

    Amat, T.

    1997-12-01

    Full Text Available This article is based on works, carried out at the IETcc, aimed to evaluate the behaviour of concretes reinforced with acrylic polyacrylonitrile fibres, and to study the influence they have on concrete physical and mechanical properties.

    El presente artículo está basado en trabajos realizados en el Instituto de Ciencias de la Construcción Eduardo Torroja, teniendo por objetivo evaluar el comportamiento de los hormigones reforzados con fibras acrílicas de poliacrilonitrilo, estudiando la influencia que tiene sobre sus propiedades físicas y mecánicas.

  5. Synthesis and characterization of acrylated Parkia biglobosa ...

    African Journals Online (AJOL)

    The results revealed that acid functional acrylic copolymers containing maleic anhydride as a functional co-monomer can successfully be used to modify alkyd resins yielding acrylated resins with better drying, flexibility, scratch hardness, impact resistance and chemical resistance properties. However there exist optimum ...

  6. Rheology of acrylic bone cements.

    Science.gov (United States)

    Ferracane, J L; Greener, E H

    1981-01-01

    The rheological properties of setting acrylic bone cements were examined with a rotational cone and plate viscometer. The cements were tested over two orders of magnitude of shear rate to determine the nature of any non-Newtonian flow behavior. All three cements behaved with moderate pseudoplasticity (i.e., shear thinning) during setting, suggesting the use of higher pressures during administration for better flow and penetration. The low viscosity brand was found to be nearly one-half as viscous as the conventional cements during the working time (i.e., 2-5 minutes). A series of sieving experiments were performed to determine the particle size distributions of the powder components. Statistical analysis (chi square) showed the cements to have different distributions, with the low viscosity brand containing a larger proportion of smaller polymer particles. This difference is thought to contribute to the lower viscosity of this cement.

  7. UV curing of nanoparticle reinforced acrylates

    Science.gov (United States)

    Bauer, F.; Flyunt, R.; Czihal, K.; Ernst, H.; Naumov, S.; Buchmeiser, M. R.

    2007-12-01

    To improve the surface hardness of radiation cured acrylate coatings, both silica nanoparticles and alumina particles with a few microns in size have been embedded into acrylate formulations. Regular mixing of nanoparticles into acrylate formulations, however, leads to highly viscous solutions inappropriate for coating procedures. The incompatibility of inorganic fillers and organic polymers can be avoided by surface modification of nanoparticles using trialkoxysilanes, which provide an interface between the two dissimilar materials. Nanoparticles modified by methacryloxypropyltrimethoxysilane (MEMO) and vinyltrimethoxysilane (VTMO), both having polymerisation-active groups, may be crosslinked with the acrylate resin. UV curing of the nanocomposites revealed an unexpected lower reactivity of the vinyl groups of VTMO modified silica compared to MEMO grafted on silica. For VTMO modification, DFT calculations showed a decrease of Mulliken atomic charge for the olefinic carbons pointing to a lower reactivity. For UV cured nano/microhybrid composites, a significant improvement of abrasion resistance was obtained.

  8. UV curing of nanoparticle reinforced acrylates

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, F. [Leibniz-Institut fuer Oberflaechenmodifizierung, Permoserstr. 15, Leipzig D-04318 (Germany)], E-mail: frank.bauer@iom-leipzig.de; Flyunt, R.; Czihal, K. [Leibniz-Institut fuer Oberflaechenmodifizierung, Permoserstr. 15, Leipzig D-04318 (Germany); Ernst, H. [University of Leipzig, Department of Experimental Physics I, Leipzig D-04103 (Germany); Naumov, S. [Leibniz-Institut fuer Oberflaechenmodifizierung, Permoserstr. 15, Leipzig D-04318 (Germany); Buchmeiser, M.R. [Leibniz-Institut fuer Oberflaechenmodifizierung, Permoserstr. 15, Leipzig D-04318 (Germany); University of Leipzig, Institute of Technical Chemistry, Leipzig D-04103 (Germany)

    2007-12-15

    To improve the surface hardness of radiation cured acrylate coatings, both silica nanoparticles and alumina particles with a few microns in size have been embedded into acrylate formulations. Regular mixing of nanoparticles into acrylate formulations, however, leads to highly viscous solutions inappropriate for coating procedures. The incompatibility of inorganic fillers and organic polymers can be avoided by surface modification of nanoparticles using trialkoxysilanes, which provide an interface between the two dissimilar materials. Nanoparticles modified by methacryloxypropyltrimethoxysilane (MEMO) and vinyltrimethoxysilane (VTMO), both having polymerisation-active groups, may be crosslinked with the acrylate resin. UV curing of the nanocomposites revealed an unexpected lower reactivity of the vinyl groups of VTMO modified silica compared to MEMO grafted on silica. For VTMO modification, DFT calculations showed a decrease of Mulliken atomic charge for the olefinic carbons pointing to a lower reactivity. For UV cured nano/microhybrid composites, a significant improvement of abrasion resistance was obtained.

  9. Synthesis of epoxidised soya bean oil acrylate

    International Nuclear Information System (INIS)

    Hussin bin Mohd Nor; Mohamad Hilmi bin Mahmood; Dahlan bin Haji Mohd.

    1988-10-01

    An epoxy acrylate was synthesized from Asahi's epoxy resin AER 331 which is an epoxidised soya bean oil (ESBO). Triethylamine (TEA) and Hydroquinone (HQ) were used as catalyst and inhibitor respectively. Observations of the experiment are described. (author)

  10. Disinfection of denture base acrylic resin.

    Science.gov (United States)

    Lin, J J; Cameron, S M; Runyan, D A; Craft, D W

    1999-02-01

    During repair or adjustments of acrylic resin removable complete and partial dentures, particles of the acrylic resin from the interior of the prosthesis may expose dental personnel to microbial health hazards if the prosthesis has not been thoroughly disinfected. This study investigates the efficacy of a commercially prepared microbial disinfectant (Alcide) on the external and internal surfaces of acrylic resins. Four groups of acrylic resin were incubated in an experimental model to simulate the oral environment over time. Specimens were treated in 2 groups, disinfected and not disinfected, and then further grouped by breaking and not breaking. Analysis was performed with microbial colony counts, SEM, and statistical analyses. Viable microorganisms still remain on the internal and external surfaces of treated resins. Chlorine dioxide reduces, but does not eliminate, viable microorganisms on these dental prostheses.

  11. Modeling Stone Columns.

    Science.gov (United States)

    Castro, Jorge

    2017-07-11

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  12. Mechanistic insights on acrylate insertion polymerization.

    Science.gov (United States)

    Guironnet, Damien; Caporaso, Lucia; Neuwald, Boris; Göttker-Schnetmann, Inigo; Cavallo, Luigi; Mecking, Stefan

    2010-03-31

    Complexes [{(PwedgeO)PdMe}(n)] (1(n); PwedgeO = kappa(2)-P,O-Ar(2)PC(6)H(4)SO(2)O with Ar = 2-MeOC(6)H(4)) are a single-component precursor of the (PwedgeO)PdMe fragment devoid of additional coordinating ligands, which also promotes the catalytic oligomerization of acrylates. Exposure of 1(n) to methyl acrylate afforded the two diastereomeric chelate complexes [(PwedgeO)Pd{kappa(2)-C,O-CH(C(O)OMe)CH(2)CH(C(O)OMe)CH(2)CH(3)}] (3-meso and 3-rac) resulting from two consecutive 2,1-insertions of methyl acrylate into the Pd-Me bond with the same or opposite stereochemistry, respectively, in a 3:2 ratio as demonstrated by comprehensive NMR spectroscopic studies and single crystal X-ray diffraction. These six-membered chelate complexes are direct key models for intermediates of acrylate insertion polymerization, and also ethylene-acrylate copolymerization to high acrylate content copolymers. Studies of the binding of various substrates (pyridine, dmso, ethylene and methyl acrylate) to 3-meso and 3-rac show that hindered displacement of the chelating carbonyl moiety by pi-coordination of incoming monomer significantly retards, but does not prohibit, polymerization. For 3-meso,3-rac + C(2)H(4) right arrow over left arrow 3-meso-C(2)H(4,) 3-rac-C(2)H(4) an equilibrium constant K(353 K) approximately 2 x 10(-3) L mol(-1) was estimated. Reaction of 3-meso, 3-rac with methyl acrylate afforded higher insertion products [(PwedgeO)Pd(C(4)H(6)O(2))(n)Me] (n = 3, 4) as observed by electrospray ionization mass spectrometry (ESI-MS). Theoretical studies by DFT methods of consecutive acrylate insertion provide relative energies of intermediates and transition states, which are consistent with the aforementioned experimental observations, and give detailed insights to the pathways of multiple consecutive acrylate insertions. Acrylate insertion into 3-meso,3-rac is associated with an overall energy barrier of ca. 100 kJ mol(-1).

  13. Sticky Glass - Structural bonded joints with acrylates

    OpenAIRE

    WELLER, Bernhard; VOGT, Iris

    2009-01-01

    p. 2982-2989 UV and light curing acrylates present a whole host of possibilities for designing glass construction with adhesively bonded joints. Their clear and colourless appearance produces a transparent and lightweight construction. Short curing times consisting of no more than mere minutes allow for quick production with minimal downtime within the overall process. Processing can resume immediately once bonding has occurred. The advantages of acrylates can be silhouetted against the...

  14. Production of medical radioisotopes in ORNL 86-Inch Cyclotron

    International Nuclear Information System (INIS)

    Skidmore, M.R.

    1975-01-01

    Procedures, targets, and costs are discussed for the production of iodine-123 at the ORNL 86-Inch Cyclotron. The cyclotron is a fixed frequency machine producing 22-MeV proton beams with currents of 3 mA. Flat plate targets are used in the bombardment of readily fabricated metals when highest production rates are necessary, while capsule targets are used when flat plate coatings are difficult or when high production rates are not required. Window targets with metal foils or powders, inorganic compounds, or isotopically enriched materials are also used. (PMA)

  15. ( Anogeissus leiocarpus ) timber columns

    African Journals Online (AJOL)

    A procedure for designing axially loaded Ayin (Anogeissus leiocarpus) wood column or strut has been investigated. Instead of the usual categorization of columns into short, intermediate and slender according to the value of slenderness ratio, a continuous column formula representing the three categories was derived.

  16. Investigation of Gas Holdup in a Vibrating Bubble Column

    Science.gov (United States)

    Mohagheghian, Shahrouz; Elbing, Brian

    2015-11-01

    Synthetic fuels are part of the solution to the world's energy crisis and climate change. Liquefaction of coal during the Fischer-Tropsch process in a bubble column reactor (BCR) is a key step in production of synthetic fuel. It is known from the 1960's that vibration improves mass transfer in bubble column. The current study experimentally investigates the effect that vibration frequency and amplitude has on gas holdup and bubble size distribution within a bubble column. Air (disperse phase) was injected into water (continuous phase) through a needle shape injector near the bottom of the column, which was open to atmospheric pressure. The air volumetric flow rate was measured with a variable area flow meter. Vibrations were generated with a custom-made shaker table, which oscillated the entire column with independently specified amplitude and frequency (0-30 Hz). Geometric dependencies can be investigated with four cast acrylic columns with aspect ratios ranging from 4.36 to 24, and injector needle internal diameters between 0.32 and 1.59 mm. The gas holdup within the column was measured with a flow visualization system, and a PIV system was used to measure phase velocities. Preliminary results for the non-vibrating and vibrating cases will be presented.

  17. Remote target removal for the Oak Ridge 86-inch Cyclotron

    International Nuclear Information System (INIS)

    Walls, A.A.

    1982-01-01

    A remotely operated target remover has been plaed in operation at the 86-Inch Cyclotron located in Oak Ridge. The system provides for the remote removal of a target from inside the cyclotron, loading it into a cask, and the removal of the cask from the 1.5 m (5-ft) shielding walls. The remote system consists of multiple electrical and pneumatically operated equipment which is designed for controlled step-by-step operation, operated with an electrical control panel, and monitored by a television system. The target remover has reduced the radiation exposures to operating personnel at the facility and has increased the effective operating time. The system is fast, requires a minimum of skill to operate, and has demonstrated both reliability and durability

  18. Seismic fragility test of a 6-inch diameter pipe system

    International Nuclear Information System (INIS)

    Chen, W.P.; Onesto, A.T.; DeVita, V.

    1987-02-01

    This report contains the test results and assessments of seismic fragility tests performed on a 6-inch diameter piping system. The test was funded by the US Nuclear Regulatory Commission (NRC) and conducted by ETEC. The objective of the test was to investigate the ability of a representative nuclear piping system to withstand high level dynamic seismic and other loadings. Levels of loadings achieved during seismic testing were 20 to 30 times larger than normal elastic design evaluations to ASME Level D limits would permit. Based on failure data obtained during seismic and other dynamic testing, it was concluded that nuclear piping systems are inherently able to withstand much larger dynamic seismic loadings than permitted by current design practice criteria or predicted by the probabilistic risk assessment (PRA) methods and several proposed nonlinear methods of failure analysis

  19. All-acrylic superelastomers: facile synthesis and exceptional mechanical behavior

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei; Goodwin, Andrew; Wang, Yangyang; Yin, Panchao; Wang, Weiyu; Zhu, Jiahua; Wu, Ting; Lu, Xinyi; Hu, Bin; Hong, Kunlun; Kang, Nam-Goo; Mays, Jimmy (Tennessee-K); (ORNL)

    2018-01-01

    All-acrylic multigraft copolymers made by a facile synthesis procedure exhibit elongation at break >1700% and strain recovery behavior far exceeding those of commercial acrylic and styrenic triblock copolymers.

  20. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  1. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  2. Waterborne hyperbranched alkyd-acrylic resin obtained by miniemulsion polymerization

    OpenAIRE

    Murillo, Edwin; López, Betty

    2016-01-01

    Abstract Four waterborne hyperbranched alkyd-acrylic resins (HBRAA) were synthesized by miniemulsion polymerization from a hyperbranched alkyd resin (HBR), methyl methacrylate (MMA), butyl acrylate (BA) and acrylic acid (AA), by using benzoyl peroxide (BPO) and ammonium persulfate (AP) as initiators. The reaction between HBR and acrylic monomers was evidenced by differential scanning calorimetric (DSC), nuclear magnetic resonance (NMR) and gel permeation chromatography (GPC). The conversion p...

  3. In-depth disinfection of acrylic resins.

    Science.gov (United States)

    Chau, V B; Saunders, T R; Pimsler, M; Elfring, D R

    1995-09-01

    This study demonstrated that bacteria penetrate three kinds of dental acrylic resin after a short time period. Samples of acrylic resin were contaminated with a variety of bacteria and were then placed in three different disinfecting solutions as directed by the manufacturers. After the specific dilution and immersion time, cultures were made from the resin samples. The only effective disinfectant was a 0.525% solution of sodium hypochlorite at a 10-minute immersion. It disinfected not only the surfaces but also the bacteria that penetrated the surfaces to a depth of 3 mm.

  4. 40 CFR 721.324 - Alkoxylated acrylate polymer (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Alkoxylated acrylate polymer (generic... Substances § 721.324 Alkoxylated acrylate polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as alkoxylated acrylate polymer...

  5. Amylase catalyzed synthesis of glycosyl acrylates and their polymerization

    NARCIS (Netherlands)

    Kloosterman, Wouter M.J.; Jovanovic, Danijela; Brouwer, Sander; Loos, Katja

    2014-01-01

    The enzymatic synthesis of novel (di)saccharide acrylates from starch and 2-hydroxyethyl acrylate, 2-hydroxyethyl methacrylate and 4-hydroxybutyl acrylate (2-HEA, 2-HEMA and 4-HBA) catalyzed by various commercially available amylase preparations is demonstrated. Both liquefaction and

  6. 21 CFR 573.120 - Acrylamide-acrylic acid resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Acrylamide-acrylic acid resin. 573.120 Section 573.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Food Additive Listing § 573.120 Acrylamide-acrylic acid resin. Acrylamide-acrylic acid resin...

  7. Investigation of Acrylic Acid at High Pressure using Neutron Diffraction

    DEFF Research Database (Denmark)

    Johnston, Blair F.; Marshall, William G.; Parsons, Simon

    2014-01-01

    This article details the exploration of perdeuterated acrylic acid at high pressure using neutron diffraction. The structural changes that occur in acrylic acid-d4 are followed via diffraction and rationalised using the Pixel method. Acrylic acid undergoes a reconstructive phase transition to a new...

  8. 21 CFR 175.210 - Acrylate ester copolymer coating.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Acrylate ester copolymer coating. 175.210 Section... COATINGS Substances for Use as Components of Coatings § 175.210 Acrylate ester copolymer coating. Acrylate ester copolymer coating may safely be used as a food-contact surface of articles intended for packaging...

  9. Poly(lauryl acrylate) and poly(stearyl acrylate) grafted multiwalled carbon nanotubes for polypropylene composites

    DEFF Research Database (Denmark)

    Daugaard, Anders Egede; Jankova Atanasova, Katja; Hvilsted, Søren

    2014-01-01

    Two new polymer grafts on an industrial grade multiwalled carbon nanotube (MWCNT) were prepared through a non-oxidative pathway employing controlled free radical polymerization for surface initiated polymer grafting. After photochemical introduction of an ATRP initiator onto the MWCNT......, polymerizations of lauryl or stearyl acrylate were performed, resulting in two novel polymer modifications on the MWCNT (poly(lauryl acrylate) or poly(stearyl acrylate)). The method was found to give time dependent loading of polymers as a function of time (up to 38 wt% for both acrylates), and showed a plateau...... in loading after 12 h of polymerization. The modified nanomaterials were melt mixed into polypropylene composites with very low filler loading (0.3 wt%), whereafter both the thermal and electrical properties were investigated by DSC and dielectric resonance spectroscopy. The electrical properties were found...

  10. Acrylate oligomers in ultraviolet cured PSA's glass transition, molecular weight versus peel strength

    International Nuclear Information System (INIS)

    Miller, H.C.

    1999-01-01

    Typically those not skilled in the art relate Glass Transition Temperature to Pressure Sensitive Adhesives. You need a low Tg material to prepare good pressure sensitive adhesives. This report deals with a wide range acrylate terminated oligomers in a standard formulation. Molecular weight, chemical structure variations are examined versus the Glass Transition of the oligomers and final peel strength. Each formulated adhesive will require unique oligomer properties to reach one hundred newtons per 100 millimeters (5.71 pounds per square inch) peel strength. Excellent peel strengths may be obtained with oligomer molecular weight ranging from six thousand to one thousand molecular weight and glass transition temperatures ranging from minus seventy four degrees centigrade up to thirteen degrees centigrade

  11. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  12. Use of Acrylic Acid Sodium Acrylate Polymer to Maintain Cocoa Seed Viability

    OpenAIRE

    Pudji Rahardjo; Faila Sophia Hartatri

    2010-01-01

    The main problem of cocoa seed storage is moisture content of the seeds because cocoa seeds will germinate if cocoa seeds moisture content is high. The objective of this research is to maintain the cocoa seeds viability in storage using acrylic acid sodium acrylate polymer (AASAP). The function of AASAP is to absorb humidity in storage due to their ability to retain water and to prevent water loss. The experiment was conducted in a laboratory of Indonesian Coffee and Cocoa Research Institute ...

  13. Thermal bulk polymerization of cholesteryl acrylate

    NARCIS (Netherlands)

    de Visser, A.C.; de Groot, K.; Feijen, Jan; Bantjes, A.

    1971-01-01

    The thermal bulk polymerization of cholesteryl acrylate was carried out in the solid phase, the mesomorphic phase, and the liquid phase to study the effect of monomer ordering on polymerization rate and polymer properties. The rate increased with decreasing ordering (or enhanced mobility) of the

  14. Biodegradation of acrylic based resins: A review.

    Science.gov (United States)

    Bettencourt, Ana F; Neves, Cristina B; de Almeida, Marise S; Pinheiro, Lídia M; Oliveira, Sofia Arantes e; Lopes, Luís P; Castro, Matilde F

    2010-05-01

    The development of different types of materials with application in dentistry is an area of intense growth and research, due to its importance in oral health. Among the different materials there are the acrylic based resins that have been extensively used either in restorations or in dentures. The objective of this manuscript was to review the acrylic based resins biodegradation phenomena. Specific attention was given to the causes and consequences of materials degradation under the oral environment. Information from scientific full papers, reviews or abstracts published from 1963 to date were included in the review. Published material was searched in dental literature using general and specialist databases, like the PubMED database. Published studies regarding the description of biodegradation mechanisms, in vitro and in vivo release experiments and cell based studies conducted on acrylic based resins or their components were evaluated. Studies related to the effect of biodegradation on the physical and mechanical properties of the materials were also analyzed. Different factors such as saliva characteristics, chewing or thermal and chemical dietary changes may be responsible for the biodegradation of acrylic based resins. Release of potential toxic compounds from the material and change on their physical and mechanical properties are the major consequences of biodegradation. Increasing concern arises from potential toxic effects of biodegradation products under clinical application thus justifying an intensive research in this area. 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. Development and Evaluation of Ketoprofen Acrylic Transdermal ...

    African Journals Online (AJOL)

    Keywords: Ketoprofen, Transdermal patch, Skin permeation, Acrylic matrix, Terpenes, Pressure- ... gastrointestinal irritation when administered orally. One promising method to reduce this adverse effect is to deliver the drug through the skin. Various methods have been tried to .... pore size = 0.45 m) prior to injection. The.

  16. SYNTHESIS AND CHARACTERIZATION OF ACRYLATED PARKIA ...

    African Journals Online (AJOL)

    a

    acid containing acrylic copolymer and a monoglyceride followed by the addition of polyol and dibasic acid has been ... superstructure of ships, the paint is also in addition to the above exposed to wind driven salt spray. Under these ... The resultant mixture was heated to 75-80 oC to break the soap stock and the neutral oil ...

  17. Large Acrylic Spherical Windows In Hyperbaric Underwater Photography

    Science.gov (United States)

    Lones, Joe J.; Stachiw, Jerry D.

    1983-10-01

    Both acrylic plastic and glass are common materials for hyperbaric optical windows. Although glass continues to be used occasionally for small windows, virtually all large viewports are made of acrylic. It is easy to uderstand the wide use of acrylic when comparing design properties of this plastic with those of glass, and glass windows are relatively more difficult to fabricate and use. in addition there are published guides for the design and fabrication of acrylic windows to be used in the hyperbaric environment of hydrospace. Although these procedures for fabricating the acrylic windows are somewhat involved, the results are extremely reliable. Acrylic viewports are now fabricated to very large sizes for manned observation or optical quality instrumen tation as illustrated by the numerous acrylic submersible vehicle hulls for hu, an occupancy currently in operation and a 3600 large optical window recently developed for the Walt Disney Circle Vision under-water camera housing.

  18. Distillation Column Flooding Predictor

    Energy Technology Data Exchange (ETDEWEB)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  19. Nuclear reactor control column

    International Nuclear Information System (INIS)

    Bachovchin, D.M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest crosssectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor

  20. Development of 8-inch Key Processes for Insulated-Gate Bipolar Transistor

    Directory of Open Access Journals (Sweden)

    Guoyou Liu

    2015-09-01

    Full Text Available Based on the construction of the 8-inch fabrication line, advanced process technology of 8-inch wafer, as well as the fourth-generation high-voltage double-diffused metal-oxide semiconductor (DMOS+ insulated-gate bipolar transistor (IGBT technology and the fifth-generation trench gate IGBT technology, have been developed, realizing a great-leap forward technological development for the manufacturing of high-voltage IGBT from 6-inch to 8-inch. The 1600 A/1.7 kV and 1500 A/3.3 kV IGBT modules have been successfully fabricated, qualified, and applied in rail transportation traction system.

  1. Lowell Observatory's 24-inch Clark Refractor: Its History and Renovation

    Science.gov (United States)

    Schindler, Kevin; Nye, Ralph; Rosenthal, Peter

    2016-01-01

    In 1895, Percival Lowell hired eminent telescope maker Alvan G. Clark to build a 24-inch refractor. Lowell intended the telescope intitally for observing Mars in support of his controversial theories about life on that planet. Clark finished the telescope within a year and at a cost of $20,000. Lowell and his staff of assistants and astronomers began observing through it on July 23, 1896, setting off a long and productive career for the telescope.While Lowell's Mars studies dominated early work with the Clark, V.M. Slipher by the 1910s was using it to observe planetary rotations and atmospheric compositions. He soon revolutionized spectroscopic studies, gathering excruciatingly long spectra - some in excess of 40 hours - of the so-called white nebula and determining startling radial velocities, evidence of an expanding universe. In the 1960s, scientists and artists teamed up on the Clark and created detailed lunar maps in support of the Apollo program.In recent decades, the Clark has played a central role in the education programs at Lowell, with general public audiences, students, and private groups all taking advantage of this unique resource.With this nearly 120 years of contant use, the Clark had been wearing down in recent years. The telescope was becoming more difficult to move, old electrical wiring in the dome was a fire hazard, and many of the telescope's parts needed to be repaired or replaced.In 2013, Lowell Observatory began a fundraising campaign, collecting $291,000 to cover the cost of dome and telescope renovation. Workers removed the entire telescope mount and tube assembly from the dome, examining every part from tube sections to individuals screws. They also stabilized the dome, adding a water vapor barrier and new outer wall while reinforcing the upper dome. The project lasted from January, 2014 through August, 2015. The facility reopened for daytime tours in September, 2015 and evening viewing the following month.

  2. Buckling of liquid columns

    NARCIS (Netherlands)

    Habibi, M.; Rahmani, Y.; Bonn, D.; Ribe, N.M.

    2010-01-01

    Under appropriate conditions, a column of viscous liquid falling onto a rigid surface undergoes a buckling instability. Here we show experimentally and theoretically that liquid buckling exhibits a hitherto unsuspected complexity involving three different modes—viscous, gravitational, and

  3. METHACRYLATE AND ACRYLATE ALLERGY IN DENTAL STUDENTS.

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2013-09-01

    Full Text Available A multitude of acrylic monomers is used in dentistry, and when dental personnel, patients or students of dental medicine become sensitized, it is of great importance to identify the dental ;acrylic preparations to which the sensitized individual can be exposed. Numerous studies confirm high incidence of sensitization to (meth acrylates in dentatal professionals, as well as in patients undergoing dental treatment and exposed to resin-based materials. Quite a few studies are available aiming to evaluate the incidence of sensitization in students of dental medicineThe purpose of the study is to evaluate the incidence of contact sensitization to some (meth acrylates in students of dental medicine at the time of their education, in dental professionals (dentists, nurses and attendants and in patients, the manifestation of co-reactivity.A total of 139 participants were included in the study, divided into four groups: occupationally exposed to (methacrylates and acrylic monomers dental professionals, 3-4 year-of-education students of dental medicine, 6th year–of-education students of dental medicine and patients with suspected or established sensitization to acrylates, without occupational exposure. All of them were patch-tested with methyl methacrylate (MMA, triethyleneglycol dimethacrylate (TREGDMA, ethyleneglycol dimethacrylate (EGDMA, 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy phenyl]propane (bis-GMA, 2-hydroxyethyl methacrylate (2-HEMA, and tetrahidrofurfuril metacrylate. The overall sensitization rates to methacrylates in the studied population are comparative high – from 25.9% for MMA to 31.7% for TREGDMA. Significantly higher incidence of sensitization in the group of 3-4 course students compared to the one in the group of dental professionals for MMA and TREGDMA was observed. Highest was the incidence of sensitization to ethyleneglycol dimethacrylate, BIS-GMA, 2-HEMA and tetrahydrofurfuryl methacrylate in the group of patients, with

  4. Solvent extraction columns

    International Nuclear Information System (INIS)

    Middleton, P.; Smith, J.R.

    1979-01-01

    In pulsed columns for use in solvent extraction processes, e.g. the reprocessing of nuclear fuel, the horizontal perforated plates inside the column are separated by interplate spacers manufactured from metallic neutron absorbing material. The spacer may be in the form of a spiral or concentric circles separated by radial limbs, or may be of egg-box construction. Suitable neutron absorbing materials include stainless steel containing boron or gadolinium, hafnium metal or alloys of hafnium. (UK)

  5. Cycloolefin effect in cycloolefin-(meth)acryl copolymer

    Science.gov (United States)

    Lim, Hyun Soon; Seo, Dong Chul; Lee, Chang Soo; Park, Sang Wok; Kim, Sang Jin; Shin, Dae Hyeon; Shin, Jin Bong; Park, Joo Hyun

    2008-11-01

    One of the most important factors in ArF resist development is a resin platform, which dominates a lot of parts of resist characteristics. It has been much changed in order to improve their physical properties such as resolution, pattern profile, etch resistance and line edge roughness. Through the low etch resistance in ArF initial (meth)acryl type copolymer and low transmittance in COMA type copolymer most researchers were interested in developing of (meth)acryl type copolymer again for ArF photoresist. On the other hand, we have studied various polymer platforms suitable ArF photoresist except for meth(acryl) type copolymer. As a result of this study we had developed ROMA type polymers and cycloolefin-(meth)acryl type copolymers. Among the polymers cycloolefin-(meth)acryl type copolymer has many attractions such as etch roughness, resist reflow which needs low glass transition temperature and solvent solubility. In this study, we intend to find out cycloolefin-(meth)acryl copolymer characteristics compared with (meth)acryl copolymer. And, we have tried to find out any differences between acrylate type copolymer and cycloolefin-(meth)acrylate type copolymer with various evaluation results. As a result of this study we are going to talk about the reason that the resist using acrylate type copolymer and cycloolefin-(meth)acryl type copolymer show good pattern profile while acrylate type copolymer show poor pattern profile. We also intend to explain the role of cycloolefin as a function of molecular weight variation and substitution ratio variation of cycloolefin in cycloolefin-(meth)acrylate resin.One of the most important factors in ArF resist development is a resin platform, which dominates a lot of parts of resist characteristics. It has been much changed in order to improve their physical properties such as resolution, pattern profile, etch resistance and line edge roughness. Through the low etch resistance in ArF initial (meth)acryl type copolymer and low

  6. Shear bond strength of acrylic teeth to acrylic denture base after different surface conditioning methods.

    Science.gov (United States)

    Madhav, Gajula Venu; Raj, Soundar; Yadav, Naveen; Mudgal, Ishitha; Mehta, Nidhi; Tatwadiya, Riddhi

    2013-09-01

    Acrylic resin ruled the dental profession for 60 years, and this success is attributed to its aesthetics, handling properties, physical and biological compatibility, its stability in oral environment and its cost effectiveness. The objective of this study is to evaluate and compare the bond strength of acrylic resin teeth treated with various conditioning materials like monomer and silane coupling agent. METHDOLOGY: A study was carried out in which 96 samples were grouped into 3 groups with a sample size of 32 each (16 premolars, 16 molars). They were conditioned with different conditioning materials i,e monomer and silane coupling agent. Monomer, Silane coupling agent are coated on the ridge lap area before thermocycling and cured according to the manufacturer recommendations. The samples are retained from the fask; trimmed and polished. The samples are then subjected to shear bond strength using the Insteron Universal Testing Machine. In the present study it was found that application of monomer increased the bond strength between acrylic teeth and denture base, when compared to the conventionally processed samples. However it was found that application of silane coupling agent further increased the shear bond strength between acrylic teeth and denture base. Interprations and Within the confnes of this study it is found that there was a signifcant improvement in the bond strength between the acrylic teeth and denture base when silane coupling agent and monomer were used as surface conditioning material. The order of shear strength of samples is control > monomer > silane coupling agent.

  7. 16 CFR 460.20 - R-value per inch claims.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false R-value per inch claims. 460.20 Section 460.20 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES LABELING AND ADVERTISING OF HOME INSULATION § 460.20 R-value per inch claims. In labels, fact sheets, ads, or other promotional...

  8. Orthopedic stretcher with average-sized person can pass through 18-inch opening

    Science.gov (United States)

    Lothschuetz, F. X.

    1966-01-01

    Modified Robinson stretcher for vertical lifting and carrying, will pass through an opening 18 inches in diameter, while containing a person of average height and weight. A subject 6 feet tall and weighing 200 pounds was lowered and raised out of an 18 inch diameter opening in a tank to test the stretcher.

  9. Torque expression of 0.018 and 0.022 inch conventional brackets

    NARCIS (Netherlands)

    Sifakakis, I.; Pandis, N.; Makou, M.; Eliades, T.; Katsaros, C.; Bourauel, C.

    2013-01-01

    The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond(R) Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch.

  10. Comparison of silicon strip tracker module size using large sensors from 6 inch wafers

    CERN Multimedia

    Honma, Alan

    1999-01-01

    Two large silicon strip sensor made from 6 inch wafers are placed next to each other to simulate the size of a CMS outer silicon tracker module. On the left is a prototype 2 sensor CMS inner endcap silicon tracker module made from 4 inch wafers.

  11. Acrylated Chitosan Nanoparticles with Enhanced Mucoadhesion

    Directory of Open Access Journals (Sweden)

    Shaked Eliyahu

    2018-01-01

    Full Text Available The aim of this study was to investigate the effect of acrylate modification on the mucoadhesion of chitosan at the nanoscale. Nanoparticles were fabricated from acrylated chitosan (ACS via ionic gelation with tripolyphosphate and were characterized in terms of size, zeta potential, stability, and nanoparticle yield. Chitosan (CS nanoparticles, serving as a control, were fabricated using the same procedure. The mucoadhesion of the nanoparticles was evaluated using the flow-through method after different incubation periods. The retention percentages of ACS nanoparticles were found to be significantly higher than those of CS nanoparticles, for all studied time intervals. An additional indication for the increased mucoadhesion of ACS nanoparticles was the increase in particle size obtained from the mucin particle method, in which mucin and nanoparticles are mixed at different ratios. NMR data verified the presence of free acrylate groups on the ACS nanoparticles. Thus, the improved mucoadhesion could be due to a Michael-type addition reaction between the nanoparticles and thiol groups present in mucin glycoprotein, in addition to entanglements and hydrogen bonding. Overall, ACS nanoparticles exhibit enhanced mucoadhesion properties as compared to CS nanoparticles and could be used as vehicles for drug delivery systems.

  12. Test procedure for the Master-Lee and the modified Champion four inch hydraulic cutters

    International Nuclear Information System (INIS)

    Crystal, J.B.

    1995-01-01

    The Master-Lee and the modified Champion 4 Inch hydraulic cutters are being retested to gather and document information related to the following: determine if the Master-Lee cutters will cut the trunnions of an Aluminum fuel canister and a Stainless Steel fuel canister; determine if the Master-Lee cutters will cut 1 1/2 inch diameter fire hose; determine if the modified Champion 4 inch blade will cut sections of piping; and determine the effectiveness of the centering device for the Champion 4 Inch cutters. Determining the limitations of the hydraulic cutter will aid in the process of debris removal in the K-Basin. Based on a previous test, the cutters were returned to the manufacturer for modifications. The modifications to the Champion 4 Inch Cutter and further testing of the Master-Lee Cutter are the subjects of these feature tests

  13. Waterborne hyperbranched alkyd-acrylic resin obtained by miniemulsion polymerization

    Directory of Open Access Journals (Sweden)

    Edwin Murillo

    Full Text Available Abstract Four waterborne hyperbranched alkyd-acrylic resins (HBRAA were synthesized by miniemulsion polymerization from a hyperbranched alkyd resin (HBR, methyl methacrylate (MMA, butyl acrylate (BA and acrylic acid (AA, by using benzoyl peroxide (BPO and ammonium persulfate (AP as initiators. The reaction between HBR and acrylic monomers was evidenced by differential scanning calorimetric (DSC, nuclear magnetic resonance (NMR and gel permeation chromatography (GPC. The conversion percentage, glass transition temperature (Tg, content of acrylic polymer (determined by soxhlet extraction and molecular weight increased with the content of acrylic monomers used in the synthesis. The main structure formed during the synthesis was the HBRAA. The analysis by dynamic light scattering (DLS showed that the particle size distribution of HBRAA2, HBRAA3 and HBRAA4 resins were mainly monomodal. The film properties (gloss, flexibility, adhesion and drying time of the HBRAA were good.

  14. Five points on columns

    Directory of Open Access Journals (Sweden)

    Kathleen S Rockland

    2010-06-01

    Full Text Available Abstract “Column,” like “gene,” has both conceptual and linguistic shortcomings. The simple question “what is a column” is not easy to answer and the word itself is not easy to replace. In the present article, I have selected five points, in no way comprehensive or canonical, but which may nevertheless serve as a prompt and aid for further discussions and reevaluation. These are: that anatomical columns are not solid structures, that they are part of locally interdigitating systems, that any delimited column also participates in a widely distributed network, that columns are not an obligatory cortical feature, and that columns (as “modules” occur widely in the brain in non-cortical structures. I focus on the larger scale macrocolumns, mainly from an anatomical perspective. My position is that cortical organization is inherently dynamic and likely to incorporate multiple processing styles. One can speculate that the distributed mappings within areas like piriform cortex may resemble at least one mode of neocortical processing strategy.

  15. Decoding the Pantheon Columns

    Directory of Open Access Journals (Sweden)

    Gerd Grasshoff

    2014-06-01

    Full Text Available The goal of this study has been to reconstruct the design principles underlying the construction of the Pantheon’s portico columns as well as to demonstrate how digital investigation methods and models can be used to improve our understanding of ancient architectural knowledge. Thanks to the data of the Bern Digital Pantheon Model, a synthesis of all the scanned surface points obtained during a digitization campaign of the Karman Center for Advanced Studies in the Humanities of the University of Bern in 2005, we have been able to determine empirically the column profiles of the portico with unprecedented precision. A second stage of our investigation involved explaining the profile of the column shafts by a construction model that takes into account the parameters recommended by Vitruvius and design methods such as those that can be found in the construction drawings discovered at Didyma. Our analysis shows that the design principles of the portico’s columns can be successfully reconstructed, and has led to the surprising result that at least two different variants of a simple circle construction were used. Finally, we have been able to deduce from the distribution of the different profile types among the columns that the final profiles were designed and executed in Rome.

  16. Assembly for connecting the column ends of two capillary columns

    International Nuclear Information System (INIS)

    Kolb, B.; Auer, M.; Pospisil, P.

    1984-01-01

    In gas chromatography, the column ends of two capillary columns are inserted into a straight capillary from both sides forming annular gaps. The capillary is located in a tee out of which the capillary columns are sealingly guided, and to which carrier gas is supplied by means of a flushing flow conduit. A ''straight-forward operation'' having capillary columns connected in series and a ''flush-back operation'' are possible. The dead volume between the capillary columns can be kept small

  17. Investigation of Acrylic Acid at High Pressure Using Neutron Diffraction

    OpenAIRE

    Johnston, Blair F.; Marshall, William G.; Parsons, Simon; Urquhart, Andrew J.; Oswald, Iain D. H.

    2014-01-01

    This article details the exploration of perdeuterated acrylic acid at high pressure using neutron diffraction. The structural changes that occur in acrylic acid-d4 are followed via diffraction and rationalized using the Pixel method. Acrylic acid undergoes a reconstructive phase transition to a new phase at ∼0.8 GPa and remains molecular to 7.2 GPa before polymerizing on decompression to ambient pressure. The resulting product is analyzed via Raman and FT-IR spectroscopy and differential scan...

  18. Ultrasonic cleaning reduces the residual monomer in acrylic resins

    OpenAIRE

    Charasseangpaisarn, Taksid; Wiwatwarrapan, Chairat; Leklerssiriwong, Nonthida

    2016-01-01

    Background/purpose: The residual monomer remaining in acrylic resin can cause an allergic reaction and is toxic to oral soft tissue. This study determined the effect of the duration of ultrasonic cleaning on the amount of residual methyl methacrylate monomer in one heat-polymerized acrylic resin, Meliodent, and three autopolymerized acrylic resins, Unifast Trad Ivory, Unifast Trad Pink, and Unifast III. Materials and methods: Thirty-six disc-shaped specimens of each brand were prepared and...

  19. Palm oil based polyols for acrylated polyurethane production

    International Nuclear Information System (INIS)

    Rida Tajau; Mohd Hilmi Mahmood; Mek Zah Salleh; Khairul Zaman Mohd Dahlan; Rosley Che Ismail

    2006-01-01

    Palm oil becomes important renewable resources for the production of polyols for the polyurethane manufacturing industry. The main raw materials used for the production of acrylated polyurethane are polyols, isocyanates and hydroxyl terminated acrylate compounds. In these studies, polyurethane based natural polymer (palm oil), i.e., POBUA (Palm Oil Based Urethane Acrylate) were prepared from three different types of palm oil based polyols i.e., epoxidised palm oil (EPOP), palm oil oleic acid and refined, bleached and deodorized (RBD) palm olein based polyols. The performances of these three acrylated polyurethanes when used for coatings and adhesives were determined and compared with each other. (Author)

  20. Synthesis and characterization of acrylated Parkia biglobosa medium oil alkyds

    Directory of Open Access Journals (Sweden)

    E.T. Akintayo

    2004-12-01

    Full Text Available Acrylated Parkia biglobosa medium oil alkyd prepared by the reaction between an acid containing acrylic copolymer and a monoglyceride followed by the addition of polyol and dibasic acid has been investigated for improved properties. The results revealed that acid functional acrylic copolymers containing maleic anhydride as a functional co-monomer can successfully be used to modify alkyd resins yielding acrylated resins with better drying, flexibility, scratch hardness, impact resistance and chemical resistance properties. However there exist optimum levels for modification of alkyds with such copolymers beyond which certain film properties are adversely affected.

  1. Occupational allergic contact dermatitis due to acrylates in Lodz.

    Science.gov (United States)

    Kiec-Swierczynska, M K

    1996-06-01

    Among 1619 patients suspected of occupational contact dermatitis examined during the years 1990-1994, sensitivity to acrylates was diagnosed in 9 persons (4 dental technicians, 4 dentists, 1 textile printer). Ethyleneglycol dimethacrylate (5 positive patch tests), methyl methacrylate (4), 2-hydroxyethyl methacrylate (4) and triethyleneglycol dimethacrylate (4) were the most common sensitizers. Comparison of patch test results in dental technicians and dentists indicated that dentists were sensitive to a greater number of (meth)acrylate (acrylate and methacrylate) allergens and also to certain other allergens (metals and rubber additives). Dental technicians were sensitive almost exclusively to methacrylates, while the textile printer only to acrylates.

  2. Slender CRC Columns

    OpenAIRE

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    CRC is a high-performance steel fibre reinforced concrete with a typical compressive strength of 150 MPa. Design methods for a number of structural elements have been developed since CRC was invented in 1986, but the current project set out to further investigate the range of columns for which current design guides can be used. The columns tested had a slenderness varying from 1.11 to 12.76 and a reinforcement ratio (area of rebar to area of concrete) ranging from 0 to 8.8 %. A total of 77 te...

  3. ADVANCED DIAGNOSTIC TECHNIQUES FOR THREE-PHASE SLURRY BUBBLE COLUMN REACTORS(SBCR)

    Energy Technology Data Exchange (ETDEWEB)

    M.H. Al-Dahhan; L.S. Fan; M.P. Dudukovic

    2002-07-25

    This report summarizes the accomplishment made during the third year of this cooperative research effort between Washington University, Ohio State University and Air Products and Chemicals. Data processing of the performed Computer Automated Radioactive Particle Tracking (CARPT) experiments in 6 inch column using air-water-glass beads (150 {micro}m) system has been completed. Experimental investigation of time averaged three phases distribution in air-Therminol LT-glass beads (150 {micro}m) system in 6 inch column has been executed. Data processing and analysis of all the performed Computed Tomography (CT) experiments have been completed, using the newly proposed CT/Overall gas holdup methodology. The hydrodynamics of air-Norpar 15-glass beads (150 {micro}m) have been investigated in 2 inch slurry bubble column using Dynamic Gas Disengagement (DGD), Pressure Drop fluctuations, and Fiber Optic Probe. To improve the design and scale-up of bubble column reactors, a correlation for overall gas holdup has been proposed based on Artificial Neural Network and Dimensional Analysis.

  4. Practical column design guide

    CERN Document Server

    Nitsche, M

    2017-01-01

    This book highlights the aspects that need to be considered when designing distillation columns in practice. It discusses the influencing parameters as well as the equations governing them, and presents several numerical examples. The book is intended both for experienced designers and for those who are new to the subject.

  5. Columns in Clay

    Science.gov (United States)

    Leenhouts, Robin

    2010-01-01

    This article describes a clay project for students studying Greece and Rome. It provides a wonderful way to learn slab construction techniques by making small clay column capitols. With this lesson, students learn architectural vocabulary and history, understand the importance of classical architectural forms and their influence on today's…

  6. Steel column base classification

    OpenAIRE

    Jaspart, J.P.; Wald, F.; Weynand, K.; Gresnigt, A.M.

    2008-01-01

    The influence of the rotational characteristics of the column bases on the structural frame response is discussed and specific design criteria for stiffness classification into semi-rigid and rigid joints are derived. The particular case of an industrial portal frame is then considered. Peer reviewed

  7. European Analytical Column

    DEFF Research Database (Denmark)

    Karlberg, B.; Grasserbauer, M.; Andersen, Jens Enevold Thaulov

    2009-01-01

    The European Analytical Column has once more invited a guest columnist to give his views on various matters related to analytical chemistry in Europe. This year, we have invited Professor Manfred Grasserbauer of the Vienna University of Technology to present some of the current challenges for Eur...

  8. Electron beam curing of acrylic oligomers

    International Nuclear Information System (INIS)

    Seto, J.; Arakawa, S.; Ishimoto, C.; Miyashita, M.; Nagai, T.; Noguchi, T.; Shibata, A.

    1984-01-01

    The electron-beam curing process of acrylic oligomers, with and without γ-Fe 2 O 3 pigment filler and blended linear polymer, was investigated in terms of molecular structure and reaction mechanism. The polymerized fraction of trimethylolpropane-triacrylate (TMPTA) oligomers increases with increasing total dose, and is independent of the dose rate. Since the reaction rate is linearly dependent on the dose rate, the reaction mechanism involves monomolecular termination. The reaction rate does not depend on the number of functional groups of the oligomer at low doses, but above 0.3 Mrad the rate is slower for oligomers of higher functionality. A gel is formed more readily upon curing of a polyfunctional than a monofunctional oligomer, especially at high conversion to polymer; the resulting loss of flexibility of the polymer chains slows the reaction. Decrease of the molecular weight per functional group results in lower conversion; this is also due to the loss of chain flexibility, which is indicated as well by a higher glass-transition temperature. Modification of the acrylate oligomers with urethane results in more effective cross-linking reactions because of the more rigid molecular chains. Addition of γ-Fe 2 O 3 pigment reduces the reaction rate very little, but has the effect of providing added structural integrity, as indicated by the decrease of solvent-extractable material and the improvement of anti-abrasion properties. However, the flexibility of the coating and its adhesion to a PET base film are diminished. To increase the flexibility, linear polyvinylchloride and/or polyurethane were added to the acrylic oligomers. Final conversion to polymer was nearly 100 percent, and a higher elastic modulus and better antiabrasion properties were realized

  9. Ionizing radiation-induced copolymerization of 2-ethylhexyl acrylate and acrylic acid and ionomer formation

    Science.gov (United States)

    Weaver, Alia

    The ionizing radiation-induced polymerization of acrylate esters is a technique employed for the curing of such materials for a variety of adhesive, coating, ink, and lithographic applications. The work presented in this dissertation involves the synthesis of a copolymer composed of 2-ethylhexyl acrylate (2-EHA) and acrylic acid (AA) using pulsed electron beam and gamma irradiation. The structure and synthesis kinetics of this copolymer were investigated by 1H nuclear magnetic resonance (NMR), electron pulse radiolysis with kinetic spectroscopic detection (PR-KSD), and Fourier transform infrared spectroscopy (FTIR). The effects of total dose, dose rate, and acrylic acid content on the polymerization reaction were studied. The conversion of 2-EHA monomer into polymer at a given total dose was found to be enhanced at lower dose rates and higher concentrations of acrylic acid. The pulse radiolysis investigation of the polymerization of 2-EHA and AA was performed through studies of four different types of systems: (i) neat 2-EHA, (ii) 2-EHA/methanol (MeOH) solutions, (iii) mixtures of 2-EHA and AA, and (iv) 2-EHA/AA/MeOH solutions. The build-up of carbon-centered neutral 2-EHA free radicals in neat 2-EHA was found to obey a second order rate law with a rate coefficient of ((7 +/- 3) x 108)epsilon EHA·, whereas in 2-EHA/AA mixtures it was found to obey a pseudo-first order rate law with a rate coefficient of (1.5 +/- 0.3) x 10 10 mol-1 dm3 s-1. This phenomenon is suggested to originate in the increased H+ ion concentration in the presence of acrylic acid, which leads to a faster neutralization step of 2-EHA radical anions as they are transformed into neutral free radicals during the initiation step of the reaction. An investigation of the formation of ion-containing copolymers (known as ionomers) was performed using the radiation-synthesized poly(2-EHA-co-AA) and iron cations. Verification of successful incorporation of iron into the copolymer was identified by an

  10. MT. BIGELOW 61-INCH IMAGES OF 9P/TEMPEL 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains 6 images of 9P/Tempel 1 obtained on five nights in 1994 using a visual CCD mounted on the 61-inch Kuiper telescope of the Mt. Bigelow...

  11. Project W320 52-inch diameter equipment container load test: Test report

    International Nuclear Information System (INIS)

    Bellomy, J.R.

    1995-01-01

    This test report summarizes testing activities and documents the results of the load tests performed on-site and off-site to structural qualify the 52-inch equipment containers designed and fabricated under Project W-320

  12. Artificial saliva effect on toxic substances release from acrylic resins

    Directory of Open Access Journals (Sweden)

    Kostić Milena

    2015-01-01

    Full Text Available Background/Aim. Acrylic-based resins are intensively used in dentistry practice as restorative or denture-base materials. The purpose of this study was to analyze the surface structure of denture base resins and the amount of released potentially toxic substances (PTS immediately upon polymerization and incubation in different types of artificial saliva. Methods. Storage of acrylic samples in two models of artificial saliva were performed in a water bath at the temperature of 37 ± 1°C. Analysis of the surface structure of samples was carried out using scanning electronic microscopy analysis immediately after polymerization and after the 30-day incubation. The amounts of PTS per day, week and month extracts were measured using high-pressure liquid chromatography. Results. Surface design and amount of PTS in acrylic materials were different and depended on the types and duration of polymerization. The surfaces of tested acrylates became flatter after immersing in solutions of artificial saliva. The degree of acrylic materials release was not dependent on the applied model of artificial saliva. Conclusion. In order to improve biological features of acrylic resin materials, it was recommended that dentures lined with soft or hard coldpolymerized acrylates should be kept at least 1 to 7 days in water before being given to a patient. So, as to reach high degree of biocompatibility preparation of prosthetic restorations from heat-polymerized acrylate was unnecessary. [Projekat Ministarstva nauke Republike Srbije, br. 41017

  13. The Acrylation of Glycerol: a Precursor to Functionalized Lipids

    Science.gov (United States)

    Didecanoylacryloylglycerol was synthesized from decanoic and acrylic acids and glycerol using K2O as catalyst. This reaction was carried out in hexane in a closed stainless steel reactor at 200°C for 5h. The reactants were added in a 1:3:4 glycerol:decanoic acid:acrylic acid molar ratio. The resu...

  14. Acrylate in Phaeocystis colonies does not affect the surrounding bacteria

    NARCIS (Netherlands)

    Noordkamp, DJB; Gieskes, WWC; Gottschal, JC; Forney, LJ; van Rijssel, M

    Acrylate accumulates to concentrations of 1.3-6.5 mM in the mucus of Phaeocystis colonies and may have an effect on the surrounding bacterial community, either as an inhibitor or as a carbon source. Both in the held and in the laboratory, effects of acrylate on bacterial growth and on its

  15. Nine Words - Nine Columns

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2016-01-01

    of computational and mechanical processes towards an anesthetic. Each team received a single word, translating and evolving that word first into a double-curved computational surface, next a ruled computational surface, and then a physically shaped foam mold via a 6-axis robot. The foam molds then operated...... as formwork for the shaping of wood veneer. The resulting columns ‘wear’ every aspect of this design pipeline process and display the power of process towards an architectural resolution....

  16. Slender CRC Columns

    DEFF Research Database (Denmark)

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    in standard fire conditions. The tests showed good correlation between test results and results calculated according to established deisgn guides. The fire tests demonstrate that the load capacity of slender columns can be reduced very quickly due to thermal stresses and a reduction of stiffness - also...... in cases where temperature at the rebar is still relatively low. However, guidelines for achieving acceptable fire resistance can be determined based on the test results....

  17. Nine Words - Nine Columns

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2016-01-01

    This book records the efforts of a one-week joint workshop between Master students from Studio 2B of Arkitektskolen Aarhus and Master students from the Harbin Institute of Technology in Harbin, China. The workshop employed nine action words to instigate team-based investigation into the effects o...... as formwork for the shaping of wood veneer. The resulting columns ‘wear’ every aspect of this design pipeline process and display the power of process towards an architectural resolution....

  18. Bond strength test of acrylic artificial teeth with prosthetic base

    Directory of Open Access Journals (Sweden)

    Erna Kurnikasari

    2008-07-01

    Full Text Available Denture consists of acrylic artificial teeth and acrylic prothesis base bond chemically with a bond strength of 315 kgF/cm2. Most of the commercial acrylic artificial teeth do not specify their specifications and all of those acrylic artificial teeth do not include mechanical data (bond strength. The aim of this study is to discover which acrylic artificial teeth meet ADA specification no. 15. This study is a descriptive analytic study performed to 5 acrylic artificial teeth posterior brands commonly used by dentists and technicians. From each brand, 3 sample teeth were taken. The acrylic artificial teeth were prepared into a rectangular shape and were attached between acrylic prothesis base simulation and jigs. The sample was given tensile load using a Universal Testing Machine. The amount of force that causes the teeth to be fractured was recorded and the bond strength was calculated. The results of the study show that the average value for the five acrylic artificial teeth for the five brands were as followed: Brand A, 125.993 kgF/cm2; B, 188.457 kgF/cm2; C, 175.880 kgF/cm2; D, 153.373 kgF/cm2; E, 82.839 kgF/cm2. The data can be tested statistically by using One Way ANOVA test and Dunnett test (alpha = 0.05. From the study, it is concluded that the five acrylic artificial teeth have a bond strength below the ADA specification no. 15.

  19. Monolithic column in gas chromatography.

    Science.gov (United States)

    Kurganov, A

    2013-05-02

    Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Ya-wen Guo

    2014-01-01

    Full Text Available Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. Results. The hydrophilic acrylic IOLs showed significantly lower straylight values than those of the hydrophobic acrylic IOLs in dilated pupils at 1 week and 1 month after surgery (P0.05. Moreover, no significant difference was found in straylight between natural and dilated pupils in each group at 1 week and 1 month postoperatively (P>0.05. Conclusions. Although the hydrophobic acrylic IOL induced more intraocular straylight, straylight differences among the 3 IOLs were minimal. Pupil size showed no effect on intraocular straylight; the intraocular straylight was stable 1 week after surgery.

  1. Risk assessment of K Basin twelve-inch and four-inch drain valve failure from a postulated seismic initiating event

    Energy Technology Data Exchange (ETDEWEB)

    MORGAN, R.G.

    1999-06-23

    The Spent Nuclear Fuel (SNF) Project will transfer metallic SNF from the Hanford 105 K-East and 105 K-West Basins to safe interim storage in the Canister Storage Building in the 200 Area. The initial basis for design, fabrication, installation, and operation of the fuel removal systems was that the basin leak rate which could result from a postulated accident condition would not be excessive relative to reasonable recovery operations. However, an additional potential K Basin water leak path is through the K Basin drain valves. Three twelve-inch drain valves are located in the main basin bays along the north wall. Five four-inch drain valves are located in the north and south loadout pits (NLOP and SLOP), the weasel pit, the technical viewing pit, and the discharge chute pit. The sumps containing the valves are filled with concrete which covers the drain valve body. Visual observations indicate that only the valve's bonnet and stem are exposed above the basin concrete floor for the twelve-inch drain valve and that much less of the valve's bonnet and stem are exposed above the basin concrete floor for the five four-inch drain valves. It was recognized, however, that damage of the drain valve bonnet or stem during a seismic initiating event could provide a potential K Basin water leak path. The objectives of this analysis are to: (1) evaluate the likelihood of damaging the three twelve-inch drain valves located along the north wall of the main basin and the five four-inch drain valves located in the pits from a seismic initiating event, and (2) determine the likelihood of exceeding a specific consequence (initial leak rate) from a damaged valve. The analysis process is a risk-based uncertainty analysis where each variable is modeled using available information and engineering judgement. The uncertainty associated with each variable is represented by a probability distribution (probability density function). Uncertainty exists because of the inherent

  2. Use of Acrylic Acid Sodium Acrylate Polymer to Maintain Cocoa Seed Viability

    Directory of Open Access Journals (Sweden)

    Pudji Rahardjo

    2010-08-01

    Full Text Available The main problem of cocoa seed storage is moisture content of the seeds because cocoa seeds will germinate if cocoa seeds moisture content is high. The objective of this research is to maintain the cocoa seeds viability in storage using acrylic acid sodium acrylate polymer (AASAP. The function of AASAP is to absorb humidity in storage due to their ability to retain water and to prevent water loss. The experiment was conducted in a laboratory of Indonesian Coffee and Cocoa Research Institute and in Kaliwining Experimental Garden. This experiment was arranged by factorial randomized complete design, in wich AASAP dosages 0%; 0.1% (0.1 g/100 seeds; 0.2% (0.2 g/100 seeds, 0.3% (0.3 g/100 seeds, 0,4% (0,4g/100 seeds, combined with seeds storage period 1, 2, 3 and 4 weeks. The experiment used 3 replications and each repli cation used 100 seeds. Parameter of observation consisted of percentage of seeds germinated in storage, percentage of seeds infected by fungi in storage, seeds moisture content, percentage of seeds germination after storage, and early growth of cocoa seedlings. The results of the experiment showed that AASAP application with some dosages cocoa seeds storage cause to germinate in storage during 2 weeks. AASAP application with some dosages in cocoa seeds storage for 2 weeks would not result in infection by fungi and did not significantly affect seed germination after storage for 1, 2 and 4 weeks, and percentage of germination of cocoa seed after storage for 3 weeks decreased with increase dosage of AASAP. Higher dosage of AASAP would reduce early growth of cocoa seedling. Key words : Theobroma cacao, seed, acrylic acid sodium acrylate, seed storage, viabilty.

  3. Dynamical mechanical analysis of photocrosslinked hyperbranched urethane acrylates

    Directory of Open Access Journals (Sweden)

    BRANKO DUNJIC

    2004-06-01

    Full Text Available A series of acrylate functionalized samples based on hyperbranched hydroxy-terminated polyesters with different molecular weights and different degrees of acrylation were synthesized. The obtained urethane acrylates were slightly yellow viscose liquids. Their composition was characterized by FTIR and 1H-NMR spectroscopy and their molecular weights were measured by GPC. All the synthesized samples were diluted with 25 wt.% 1,4-butanediol dimethacrylate (BDDM. The rheological properties of the uncured samples and the dynamic mechanical properties of the UV cured samples were examined. All the samples exhibit Newtonian behavior, which indicates the absence of physical entanglements in these polymers. The viscosity increases with increasing number of acrylic groups per molecule. The glass transition temperature of the UV cured samples increases with increasing the number of acrylic groups per molecule. The value of the storage modulus in the rubber-elastic plateau and the cross-link density increase with increasing number of acrylic groups per molecule. The formed networks are inhomogeneous and the residual unsaturation is the highest in the samples with the largest number of acrylic groups per molecule.

  4. COMPARATIVE ANALYSIS OF WATER SORPTION BY DIFFERENT ACRYLIC MATERIALS

    Directory of Open Access Journals (Sweden)

    Milena Kostić

    2014-06-01

    Full Text Available Acrylic materials are used daily for the production of mobile dental restorations and orthodontic appliances. The presence of residual monomer, as a product of incomplete polymerisation of material, results in more porous structure of the material, which greatly reduces the mechanical and physical quality of the acrylic restorations and increases the absorption of liquids. The aim of this study was to examine the water absorption of different types of resin material. In the study it was assumed that the cold polymerized acrylates show a greater potential for absorbing fluid from the environment in relation to the hot polymerized acrylic. The study included two hot and two cold polymerized acrylates, and cold polymerized acrylate impregnated with aesthetic pearls. In order to determine the degree of water absorption, the mass of the samples was measured before and after one day, seven days and thirty days of immersion in a water bath of body temperature. The tested hot and cold polymerized acrylates after immersion in water bath showed standard values of water absorption. The degree of water absorption was not significantly influenced by the type and manner of polymerisation. Water absorption values were significantly higher after seven days and thirty days of water storage relative to the observational period of one day.

  5. Dynamically formed hydrous zirconium (IV) oxide-polyelectrolyte membranes. III: Poly(acrylic acid) and substituted poly(acrylic acid) homo, co and terpolymer membranes

    International Nuclear Information System (INIS)

    Van Reenen, A.J.; Sanderson, R.D.

    1989-01-01

    A series of acrylic acid and substituted acrylic acid homo, co and terpolymers was synthesised. These polymers were used as polyelectrolytes in dynamically formed hydrous zirconium (iv) oxide-polyelectrolyte membranes. Substitution of the acrylic acid α-hydrogen was done to increase the number of carboxylic acid groups per monomer unit and to change the acid strength of acrylic acid carboxylic acid group. None of these changes improved the salt rejection of these membranes over that of commercially used poly(acrylic acid). Improvement in rejection was found when a hydrophobic comonomer, vinyl acetate, was used in conjunction with acrylic acid in a copolymer dynamic membrane. 16 refs., 6 figs., 1 tab

  6. Electrochemical characterization of aminated acrylic conducting polymer

    International Nuclear Information System (INIS)

    Rashid, Norma Mohammad; Heng, Lee Yook; Ling, Tan Ling

    2015-01-01

    New attempt has been made to synthesize aminated acrylic conducting polymer (AACP) using precursor of phenylvinylsulfoxide (PVS). The process was conducted via the integration of microemulsion and photopolymerization techniques. It has been utilized for covalent immobilization of amino groups by the adding of N-achryiloxisuccinimide (NAS). Thermal eliminating of benzene sulfenic acids from PVS has been done at 250 °C to form electroactive polyacetylene (PA) segment. Characterization of AACP has been conducted using fourier transform infrared (FTIR), scanning electron microscopy (SEM) and linear sweep cyclic voltammetry (CV). A range of 0.3-1.25μm particle size obtained from SEM characterization. A quasi-reversible system performed as shown in electrochemical study

  7. Column: Every Last Byte

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-06-01

    Full Text Available Inheritance powder is the name that was given to poisons, especially arsenic, that were commonly used in the 17th and early 18th centuries to hasten the death of the elderly. For most of the 17th century, arsenic was deadly but undetectable, making it nearly impossible to prove that someone had been poisoned. The first arsenic test produced a gas—hardly something that a scientist could show to a judge. Faced with a growing epidemic of poisonings, doctors and chemists spent decades searching for something better.(see PDF for full column

  8. Chemo-enzymatic synthesis route to poly(glucosyl-acrylates) using glucosidase from almonds

    NARCIS (Netherlands)

    Kloosterman, Wouter M. J.; Roest, Steven; Priatna, Siti R.; Stavila, Erythrina; Loos, Katja

    2014-01-01

    Novel types of glucosyl-acrylate monomers are obtained by beta-glucosidase from almond catalyzed glycosidation reaction. The saccharide-acrylate monomers were synthesized by reaction of D-glucose with hydroxyl functional acrylates: 2-hydroxyethyl acrylate (2-HEA), 2-hydroxyethyl methacrylate

  9. Development of gamma spectroscopy employing NaI(Tl) detector 3 inch x 3 inch and readout electronic of flash-ADC/FPGA-based technology

    Energy Technology Data Exchange (ETDEWEB)

    Hai, Vo Hong [HCMC-National Univ., Hochiminh City (Viet Nam). Inst. of Nuclear Physics; Ton Duc Thang Univ., Ho Chi Minh City (Viet Nam). Div. of Nuclear Physics; Hung, Nguyen Quoc [HCMC-National Univ., Hochiminh City (Viet Nam). Inst. of Nuclear Physics; Khai, Bui Tuan [Osaka Univ. (Japan). Dept. of Physics

    2015-05-15

    n this article the development of a gamma spectroscopy system is described using a scintillation detector NaI(Tl) of 3 inch x 3 inch. The readout electronic for the spectroscopy is built from the fast analog-digital conversion of Flash Analog-Digital Converter (Flash-ADC) 250 MHz - 8 bits resolution, and the embedded Field-Programmable Gate Array (FPGA) technology. The embedded VHSIC Hardware Description Language (VHDL) code for FPGA is built in such a way that it works as a multi channel analyser (MCA) with 4096 Digital Charge Integration (DCI) channels. A pulse generator with frequency varying from Hz up to 12 kHz is used to evaluate the time response of the system. Two standard radioisotope sources of {sup 133}Ba and {sup 152}Eu with multi gamma energies ranging from several tens keV to MeV are used to evaluate the linearity and energy resolution of the system.

  10. Annular pulse column development studies

    International Nuclear Information System (INIS)

    Benedict, G.E.

    1980-01-01

    The capacity of critically safe cylindrical pulse columns limits the size of nuclear fuel solvent extraction plants because of the limited cross-sectional area of plutonium, U-235, or U-233 processing columns. Thus, there is a need to increase the cross-sectional area of these columns. This can be accomplished through the use of a column having an annular cross section. The preliminary testing of a pilot-plant-scale annular column has been completed and is reported herein. The column is made from 152.4-mm (6-in.) glass pipe sections with an 89-mm (3.5-in.) o.d. internal tube, giving an annular width of 32-mm (1.25-in.). Louver plates are used to swirl the column contents to prevent channeling of the phases. The data from this testing indicate that this approach can successfully provide larger-cross-section critically safe pulse columns. While the capacity is only 70% of that of a cylindrical column of similar cross section, the efficiency is almost identical to that of a cylindrical column. No evidence was seen of any non-uniform pulsing action from one side of the column to the other

  11. Conversion of Lignocellulosic Biomass to Ethanol and Butyl Acrylate

    Energy Technology Data Exchange (ETDEWEB)

    Binder, Thomas [Archer Daniels Midland Company, Decatur, IL (United States); Erpelding, Michael [Archer Daniels Midland Company, Decatur, IL (United States); Schmid, Josef [Archer Daniels Midland Company, Decatur, IL (United States); Chin, Andrew [Archer Daniels Midland Company, Decatur, IL (United States); Sammons, Rhea [Archer Daniels Midland Company, Decatur, IL (United States); Rockafellow, Erin [Archer Daniels Midland Company, Decatur, IL (United States)

    2015-04-10

    Conversion of Lignocellulosic Biomass to Ethanol and Butyl Acrylate. The purpose of Archer Daniels Midlands Integrated Biorefinery (IBR) was to demonstrate a modified acetosolv process on corn stover. It would show the fractionation of crop residue to distinct fractions of cellulose, hemicellulose, and lignin. The cellulose and hemicellulose fractions would be further converted to ethanol as the primary product and a fraction of the sugars would be catalytically converted to acrylic acid, with butyl acrylate the final product. These primary steps have been demonstrated.

  12. Investigation of acrylic acid at high pressure using neutron diffraction.

    Science.gov (United States)

    Johnston, Blair F; Marshall, William G; Parsons, Simon; Urquhart, Andrew J; Oswald, Iain D H

    2014-04-10

    This article details the exploration of perdeuterated acrylic acid at high pressure using neutron diffraction. The structural changes that occur in acrylic acid-d4 are followed via diffraction and rationalized using the Pixel method. Acrylic acid undergoes a reconstructive phase transition to a new phase at ∼ 0.8 GPa and remains molecular to 7.2 GPa before polymerizing on decompression to ambient pressure. The resulting product is analyzed via Raman and FT-IR spectroscopy and differential scanning calorimetry and found to possess a different molecular structure compared with polymers produced via traditional routes.

  13. Am/Cm TTR testing - 3/8-inch glass beads evaluation in CIM5

    International Nuclear Information System (INIS)

    Witt, D. C.

    2000-01-01

    To facilitate the procurement and handling of the glass former for Am/Cm vitrification in the F-Canyon MPPF, 1/4 inch and 3/8 inch diameter glass beads were purchased from Corning for evaluation in the 5 inch Cylindrical Induction Melter (CIM5). Prior to evaluating the beads in the CIM5, tests were conducted in the Drain Tube Test Stand (DTTS) with 1/4 inch beads, 3/8 inch beads, and a 50/50 mixture to identify any process concerns. Results of the DTTS tests are summarized in Attachment 1. A somewhat larger volume expansion was experienced in all three DTTS runs as compared to a standard run using cullet. Further testing of the use of glass beads in the CIM5 was requested by the Design Authority as Task 1.02 of Technical Task Request 99-MNSS/SE-006. Since the Technical Task Plan was not yet approved, the completion of this task was conducted under an authorization request approved by the SRTC Laboratory Director, S. Wood. This request is included as Attachment 2

  14. Comparision of Incidental Reflection From Containerized Maintenance/Housekeeping Solutions and One Inch of Water

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Bryan Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); MacQuigg, Michael Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wysong, Andrew Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-12-15

    This document addresses the incidental reflector reactivity worth of containerized maintenance/housekeeping fluids for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze containerized maintenance/housekeeping fluids which will be analyzed as water that may be present under normal conditions of an operation. The reactivity worth is compared to the reactivity worth due to I-inch of close-fitting 4n water reflection and I-inch of close-fitting radial water reflection. Both have been used to bound incidental reflection by 2-liter bottles in criticality safety evaluations. The conclusion is that, when the maintenance/housekeeping fluids are containerized the reactivity increase from a configuration which is bounding of normal conditions (up to eight bottles modeled with 2-liters of solution at varying diameter) is bound by I-inch of close fitting 4n water relection.

  15. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  16. Column: File Cabinet Forensics

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-12-01

    Full Text Available Researchers can spend their time reverse engineering, performing reverse analysis, or making substantive contributions to digital forensics science. Although work in all of these areas is important, it is the scientific breakthroughs that are the most critical for addressing the challenges that we face.Reverse Engineering is the traditional bread-and-butter of digital forensics research. Companies like Microsoft and Apple deliver computational artifacts (operating systems, applications and phones to the commercial market. These artifacts are bought and used by billions. Some have evil intent, and (if society is lucky, the computers end up in the hands of law enforcement. Unfortunately the original vendors rarely provide digital forensics tools that make their systems amenable to analysis by law enforcement. Hence the need for reverse engineering.(see PDF for full column

  17. Using a nitrilase for the surface modification of acrylic fibres

    OpenAIRE

    Matamá, Maria Teresa; Carneiro, Ana Filipa Gonçalves da Costa; Caparrós Vásquez, Cristina Maria; Gübitz, Georg M.; Paulo, Artur Cavaco

    2007-01-01

    The surface of an acrylic fibre was modified with a commercial nitrilase (EC 3.5.5.1). The effect of fibre solvents and polyols on nitrilase catalysis efficiency and stability was investigated. The nitrilase action on the acrylic fabric was improved by the combined addition of 1 M sorbitol and 4% N, N-dimethylacetamide. The colour levels for samples treated with nitrilase increased 156% comparing to the control samples. When the additives were introduced in the treatment media, the colour lev...

  18. Ureido cytosine and cytosine-containing acrylic copolymers

    OpenAIRE

    Zhang, Keren; Chen, Mingtao; Drummey, Kevin J.; Talley, Samantha J.; Anderson, Lindsey J.; Moore, Robert B.; Long, Timothy E.

    2016-01-01

    Regioselective Michael addition afforded a novel N1-substituted cytosine acrylate monomer for the synthesis of acrylic random copolymers with cytosine pendant groups. Quantitative post-functionalization converted cytosine to ureido-cytosine (UCy) with an increased self-association strength due to quadruple hydrogen bond formation. Thermogravimetric analysis (TGA) revealed a lower onset temperature of weight loss (∼200 °C) for UCy-containing copolymers, however, they proved to be more thermall...

  19. Spectroscopic techniques and the conservation of artists’ acrylic emulsion paints

    OpenAIRE

    Willneff, EA; Schroeder, SLM; Ormsby, BA

    2014-01-01

    Artists’ acrylic emulsion paints are used in many contexts such as paintings, murals, sculptures, works on paper and mixed media; and are forming increasing proportions of modern and contemporary art collections. Although acrylic emulsion paints have been the focus of museum-led research over the past decade, the impact of artists’ technique and conservation treatment on the upper-most surface of these paints remains essentially unexplored ; This paper summarises previous studies using vibrat...

  20. Buckling of a holey column.

    Science.gov (United States)

    Pihler-Puzović, D; Hazel, A L; Mullin, T

    2016-09-14

    We report the results from a combined experimental and numerical investigation of buckling in a novel variant of an elastic column under axial load. We find that including a regular line of centred holes in the column can prevent conventional, global, lateral buckling. Instead, the local microstructure introduced by the holes allows the column to buckle in an entirely different, internal, mode in which the holes are compressed in alternate directions, but the column maintains the lateral reflection symmetry about its centreline. The internal buckling mode can be accommodated within a smaller external space than the global one; and it is the preferred buckling mode over an intermediate range of column lengths for sufficiently large holes. For very short or sufficiently long columns a modification of the classical, global, lateral buckling is dominant.

  1. Antimicrobial activity of poly(acrylic acid) block copolymers

    International Nuclear Information System (INIS)

    Gratzl, Günther; Paulik, Christian; Hild, Sabine; Guggenbichler, Josef P.; Lackner, Maximilian

    2014-01-01

    The increasing number of antibiotic-resistant bacterial strains has developed into a major health problem. In particular, biofilms are the main reason for hospital-acquired infections and diseases. Once formed, biofilms are difficult to remove as they have specific defense mechanisms against antimicrobial agents. Antimicrobial surfaces must therefore kill or repel bacteria before they can settle to form a biofilm. In this study, we describe that poly(acrylic acid) (PAA) containing diblock copolymers can kill bacteria and prevent from biofilm formation. The PAA diblock copolymers with poly(styrene) and poly(methyl methacrylate) were synthesized via anionic polymerization of tert-butyl acrylate with styrene or methyl methacrylate and subsequent acid-catalyzed hydrolysis of the tert-butyl ester. The copolymers were characterized via nuclear magnetic resonance spectroscopy (NMR), size-exclusion chromatography (SEC), Fourier transform infrared spectroscopy (FTIR), elemental analysis, and acid–base titrations. Copolymer films with a variety of acrylic acid contents were produced by solvent casting, characterized by atomic force microscopy (AFM) and tested for their antimicrobial activity against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. The antimicrobial activity of the acidic diblock copolymers increased with increasing acrylic acid content, independent of the copolymer-partner, the chain length and the nanostructure. - Highlights: • Acrylic acid diblock copolymers are antimicrobially active. • The antimicrobial activity depends on the acrylic acid content in the copolymer. • No salts, metals or other antimicrobial agents are needed

  2. Pressure-actuated monolithic acrylic microfluidic valves and pumps.

    Science.gov (United States)

    Guevara-Pantoja, Pablo E; Jiménez-Valdés, Rocío J; García-Cordero, Jose L; Caballero-Robledo, Gabriel A

    2018-02-13

    In this article, we describe a microfluidic device with embedded valves and pumps made exclusively of layers of acrylic glass. Flat acrylic sheets are carved out with a micromilling machine and bonded together by solvent bonding. The working principle of the valves is based on a thin flexible membrane (≈100 μm) machined on one acrylic sheet and actuated with pneumatic pressure. A completely closed valve resists a pressure difference of ≈17 kPa (≈2.5 psi), and when open, it can sustain flow rates of up to 100 μL s -1 . Pumping is achieved by combining two valves and a pumping chamber in series, which is also based on the bending of a thin acrylic membrane. The maximum flow rate obtained with this pumping mechanism is 20 μL min -1 . Acrylic is a popular rigid thermoplastic because it is inexpensive, making it ideal for mass production of disposable devices, and also because it has demonstrated compatibility with different biochemical assays. The physical and optical properties it shares with other thermoplastics could lead to this material being implemented for similar valves and pumps. As a proof-of-concept of our technology, we implemented a controlled cell-staining assay in two parallel incubation chambers integrating four valves and one pump into one device. Our monolithic acrylic valves can enable the mass production of disposable microfluidic devices that require fluid control with pressure-actuated valves and aid in the automation of biochemical assays.

  3. Antimicrobial activity of poly(acrylic acid) block copolymers

    Energy Technology Data Exchange (ETDEWEB)

    Gratzl, Günther, E-mail: guenther.gratzl@jku.at [Johannes Kepler University Linz, Institute for Chemical Technology of Organic Materials, Altenberger Str. 69, 4040 Linz (Austria); Paulik, Christian [Johannes Kepler University Linz, Institute for Chemical Technology of Organic Materials, Altenberger Str. 69, 4040 Linz (Austria); Hild, Sabine [Johannes Kepler University Linz, Institute of Polymer Science, Altenberger Str. 69, 4040 Linz (Austria); Guggenbichler, Josef P.; Lackner, Maximilian [AMiSTec GmbH and Co. KG, Leitweg 13, 6345 Kössen, Tirol (Austria)

    2014-05-01

    The increasing number of antibiotic-resistant bacterial strains has developed into a major health problem. In particular, biofilms are the main reason for hospital-acquired infections and diseases. Once formed, biofilms are difficult to remove as they have specific defense mechanisms against antimicrobial agents. Antimicrobial surfaces must therefore kill or repel bacteria before they can settle to form a biofilm. In this study, we describe that poly(acrylic acid) (PAA) containing diblock copolymers can kill bacteria and prevent from biofilm formation. The PAA diblock copolymers with poly(styrene) and poly(methyl methacrylate) were synthesized via anionic polymerization of tert-butyl acrylate with styrene or methyl methacrylate and subsequent acid-catalyzed hydrolysis of the tert-butyl ester. The copolymers were characterized via nuclear magnetic resonance spectroscopy (NMR), size-exclusion chromatography (SEC), Fourier transform infrared spectroscopy (FTIR), elemental analysis, and acid–base titrations. Copolymer films with a variety of acrylic acid contents were produced by solvent casting, characterized by atomic force microscopy (AFM) and tested for their antimicrobial activity against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. The antimicrobial activity of the acidic diblock copolymers increased with increasing acrylic acid content, independent of the copolymer-partner, the chain length and the nanostructure. - Highlights: • Acrylic acid diblock copolymers are antimicrobially active. • The antimicrobial activity depends on the acrylic acid content in the copolymer. • No salts, metals or other antimicrobial agents are needed.

  4. Cortical columns for quick brains

    OpenAIRE

    Stoop, Ralph L.; Saase, Victor; Wagner, Clemens; Stoop, Britta; Stoop, Ruedi

    2012-01-01

    It is widely believed that the particular wiring observed within cortical columns boosts neural computation. We use rewiring of neural networks performing real-world cognitive tasks to study the validity of this argument. In a vast survey of wirings within the column we detect, however, no traces of the proposed effect. It is on the mesoscopic inter-columnar scale that the existence of columns - largely irrespective of their inner organization - enhances the speed of information transfer and ...

  5. Advances in acrylic-alkyd hybrid synthesis and characterization

    Science.gov (United States)

    Dziczkowski, Jamie

    2008-10-01

    In situ graft acrylic-alkyd hybrid resins were formed by polymerizing acrylic and acrylic-mixed monomers in the presence of alkyds by introduction of a free radical initiator to promote graft formation. Two-dimensional NMR, specifically gradient heteronuclear multiple quantum coherence (gHMQC), was used to clarify specific graft sites of the hybrid materials. Both individual and mixed-monomer systems were produced to determine any individual monomer preferences and to model current acrylic-alkyd systems. Different classes of initiators were used to determine any initiator effects on graft location. The 2D-NMR results confirm grafting at doubly allylic hydrogens located on the fatty acid chains and the polyol segment of the alkyd backbone. The gHMQC spectra show no evidence of grafting across double bonds on either pendant fatty acid groups or THPA unsaturation sites for any of the monomer or mixed monomer systems. It was also determined that choice of initiator has no effect on graft location. In addition, a design of experiments using response surface methodology was utilized to obtain a better understanding of this commercially available class of materials and relate both the chemical and physical properties to one another. A Box-Behnkin design was used, varying the oil length of the alkyd phase, the degree of unsaturation in the polyester backbone, and acrylic to alkyd ratio. Acrylic-alkyd hybrid resins were reduced with an amine/water mixture. Hydrolytic stability was tested and viscoelastic properties were obtained to determine crosslink density. Cured films were prepared and basic coatings properties were evaluated. It was found that the oil length of the alkyd is the most dominant factor for final coatings properties of the resins. Acrylic to alkyd ratio mainly influences the resin properties such as acid number, average molecular weight, and hydrolytic stability. The degree of unsaturation in the alkyd backbone has minimal effects on resin and film

  6. Industrially relevant epoxy-acrylate hybrid resin photopolymerizations

    Science.gov (United States)

    Ajiboye, Gbenga I.

    Photopolymerization of epoxy-acrylate hybrid resins takes advantages of inherent properties present in the free-radical and cationic reactions to reduce oxygen inhibition problems that plague free-radical reactions. Similarly, the combined reaction mechanisms reduce moisture sensitivity of the cationic reactions. Despite the advantages of epoxy-acrylate hybrid resins, problems persist that need to be addressed. For example, low conversion and polymerization rate of the epoxides are a problem, because the fast acrylate conversion prevents the epoxide from reaching high conversion. Controlling phase separation is challenging, since two moieties with different properties are reacting. The physical properties of the polymer will be impacted by the availability of different moieties. High shrinkage stress results from the acrylate moiety, causing buckling and cracking in film and coating applications. The overall goal of this study is to use the fundamental knowledge of epoxy-acrylate hybrid resins to formulate industrially viable polymers. In order to achieve this goal, the study focuses on the following objectives: (I) determine the apparent activation energy of the hybrid monomer METHB, (II) increase epoxide conversion and polymerization rate of hybrid formulations, and (III) control physical properties in epoxy-acrylate hybrid resins. In order to increase the epoxide conversion and rate of polymerization, the sensitivity of epoxides to alcohol is used to facilitate the activated monomer (AM) mechanism and induce a covalent bond between the epoxide and acrylate polymers through the hydroxyl group. It is hypothesized that if the AM mechanism is facilitated, epoxide conversion will increase. As a result, the resins can be tailored to control phase separation and physical properties, and shrinkage stress can be reduced. In pursuit of these objectives, the hybrid monomer METHB was polymerized at temperatures ranging from 30°C to 70°C to obtain apparent activation

  7. Evaluation of 3 Inch SN-219 Failure and S and SX Tank Farm Saltwell Piping

    International Nuclear Information System (INIS)

    ELSEN, J.J.

    2000-01-01

    Evaluation of direct buried piping currently in use or designated for future Saltwell pumping in S and SX Farms. Documented evaluation of failed S-103 saltwell pumping transfer line 3 inch SN-219. This evaluation is intended to reflect current status of Saltwell piping, when taken in context with referenced documents

  8. Full scale ambient water flow tests of a 10-inch emergency release coupling for LNG transfer

    NARCIS (Netherlands)

    Putte, L.J. van der; Webber, T.; Bokhorst, E. van; Revell, C.

    2016-01-01

    For LNG transfer in ship-to-ship and ship-to-shore configurations emergency release couplings (F.RC) in combination with loading arms and multi-composite hoses are applied In view of a demand for increasing transfer flow rates in offshore LNG applications a 10-inch ERC has been developed intended

  9. Interim results: fines recycle testing using the 4-inch diameter primary graphite burner

    International Nuclear Information System (INIS)

    Palmer, W.B.

    1975-05-01

    The results of twenty-two HTGR primary burner runs in which graphite fines were recycled pneumatically to the 4-inch diameter pilot-plant primary fluidized-bed burner are described. The result of the tests showed that zero fines accumulation can easily be achieved while operating at plant equivalent burn rates. (U.S.)

  10. SURFACE ENERGETIC CHARACTERISTICS OF ACRYLIC BIOMATERIALS

    Directory of Open Access Journals (Sweden)

    Mihaela-Papusa Vasiliu (Diaconu

    2011-09-01

    Full Text Available Introduction: Surface energetic characteristics of biomaterials influence their adherence to cells and bacteria, surface adsobtion of plasmatic proteins, as well as the capacity of such surfaces of immobilizing some biological species extremely important in medicine. Materials and method: Acrylic surfaces with an area of approximately 2 cm² were employed for the experiments: Duracryl® Plus (Spofa/Dental Product, Czechia, Duracryl® Plus covered with Palaseal (Heraeus Kulzer GmbH, Wehrheim, Germany; artificial saliva AFNOR S90-701 (pH 8.01 was used as a working solution. Results and discussion: Drops of distilled water and artificial saliva, deposited on the working materials: Duracryl and Duracryl covered with Palaseal, were photographed with an optical device, after which each drop was computer-processed, and the contact angle for each liquid surface on the surfaces of the biomaterials here under investigation was determined. On the basis of the determinations made for each material in part, the arihtmetic mean was established. Conclusions: The wettability of dental materials is wholly characterized by the values of the contact angle between the drop of biological liquid and the surface. Low values of the contact angles indicate a good wettability. The results obtained support the conclusion that the surface energy of the solid and rugosity are essential for controlling the adhesive properties of saliva unto dental materials.

  11. Clinical Aspects of Combination of Ceramic and Acrylic Occlusal Surfaces

    Directory of Open Access Journals (Sweden)

    Z. Ozhohan

    2017-03-01

    Full Text Available The objective of the research was to develop and substantiate the methods of constructing the occlusal surfaces when manufacturing aesthetic fixed restorations through the combination of different materials. Materials and methods. The study included 65 patients with ceramic and acrylic occlusal surfaces of aesthetic fixed dental prostheses. Group I included 21 patients with a combination of ceramic and acrylic occlusal surfaces. Group II included 22 patients with a combination of ceramic occlusal surfaces. Group III included 22 patients with a combination of acrylic occlusal surfaces. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. The greatest increase in the occlusal contact surface area of fixed restorations was observed in Group I, that is, when combining dental prostheses with ceramic and acrylic occlusal surfaces. Considering uneven abrasion of the occlusal surfaces, we do not recommend to combine different materials when veneering the occlusal surface of the antagonistic teeth. Conclusions. This study demonstrated the important role of the correct combination of materials when veneering the occlusal surfaces. Physical and chemical properties of materials, namely the abrasion resistance play a significant role in the long-term denture functioning. The smallest increase in the occlusal contact surface area was observed in Group II when combining ceramic occlusal surfaces. It was due to a good abrasion resistance of ceramics as compared to acrylic resin as well as the presence of the glazed layer which prevents the premature abrasion of the occlusal surfaces of the antagonistic teeth due to lower surface roughness. The combination of acrylic resin and ceramics when constructing the occlusal surfaces of fixed restorations in Group I demonstrated the highest rate of the increase in the occlusal contact surface area – 9.93%. It was due to a low hardness of acrylic resin and its high surface roughness. In

  12. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  13. Large deformation micromechanics of particle filled acrylics at elevated temperatures

    Science.gov (United States)

    Gunel, Eray Mustafa

    The main aim of this study is to investigate stress whitening and associated micro-deformation mechanism in thermoformed particle filled acrylic sheets. For stress whitening quantification, a new index was developed based on image histograms in logarithmic scale of gray level. Stress whitening levels in thermoformed acrylic composites was observed to increase with increasing deformation limit, decreasing forming rate and increasing forming temperatures below glass transition. Decrease in stress whitening levels above glass transition with increasing forming temperature was attributed to change in micro-deformation behavior. Surface deformation feature investigated with scanning electron microscopy showed that source of stress whitening in thermoformed samples was a combination of particle failure and particle disintegration depending on forming rate and temperature. Stress whitening level was strongly correlated to intensity of micro-deformation features. On the other hand, thermoformed neat acrylics displayed no surface discoloration which was attributed to absence of micro-void formation on the surface of neat acrylics. Experimental damage measures (degradation in initial, secant, unloading modulus and strain energy density) have been inadequate in describing damage evolution in successive thermoforming applications on the same sample at different levels of deformation. An improved version of dual-mechanism viscoplastic material model was proposed to predict thermomechanical behavior of neat acrylics under non-isothermal conditions. Simulation results and experimental results were in good agreement and failure of neat acrylics under non-isothermal conditions ar low forming temperatures were succesfully predicted based on entropic damage model. Particle and interphase failure observed in acrylic composites was studied in a multi-particle unit cell model with different volume fractions. Damage evolution due to particle failure and interphase failure was simulated

  14. Attachment of Streptococcus oralis on acrylic substrates of varying roughness.

    Science.gov (United States)

    Charman, K M; Fernandez, P; Loewy, Z; Middleton, A M

    2009-04-01

    To determine the effect of the surface roughness of denture acrylic on the attachment of Streptococcus oralis. Roughened denture acrylic samples were assessed for bacterial attachment, over time, using microscopy. The area of the image covered by bacteria was calculated and converted into a percentage of the total area sampled. The results showed an increasing bacterial coverage with time of incubation and increasing roughness. Differences were seen between heat cured acrylic and cold cured acrylic. This study successfully demonstrated a system for the assessment of the amount of attached bacteria on denture acrylic varying roughness. The system was able to discern the difference in surface area coverage by attached bacteria over a roughness range relevant to brushing dentures with dentifrices. This study provides strong support for the scratches caused by brushing dentures with dentifrice encouraging bacterial attachment. This is likely to have a significant effect on efficacy of denture cleaning, general hygiene and biofilm re-formation between cleaning regimens and may indicate that alternative low abrasive cleaners, such as antimicrobial denture-cleaning tablets, offer a more appropriate regimen.

  15. New acrylic resin composite with improved thermal diffusivity.

    Science.gov (United States)

    Messersmith, P B; Obrez, A; Lindberg, S

    1998-03-01

    Studies have shown that physical characteristics of denture base materials may affect patient acceptance of denture prostheses by altering sensory experience of food during mastication. Thermal diffusivity is one material property that has been cited as being important in determining gustatory response, with denture base acrylic resins having low thermal diffusivity compared with denture base metal alloys. This study prepared and characterized experimental acrylic resin composite material with increased thermal diffusivity. Sapphire (Al2O3) whiskers were added to conventional denture base acrylic resin during processing to achieve loadings of 9.35% and 15% by volume. Cylindrical test specimens containing an embedded thermocouple were used to determine thermal diffusivity over a physiologic temperature range (0 degree to 70 degrees C). Thermal diffusivities of the sapphire containing composites were found to be significantly higher than the unmodified acrylic resin. Thermal diffusivity was found to increase in proportion to the volume percentage of sapphire filler, which suggested that the high aspect ratio ceramic particles formed a pathway for heat conduction through the insulating polymer matrix. The thermal diffusivity of denture base acrylic resin was increased by the addition of thermally conducting sapphire whiskers.

  16. Column-Oriented Database Systems (Tutorial)

    NARCIS (Netherlands)

    D. Abadi; P.A. Boncz (Peter); S. Harizopoulos

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as

  17. Fabrication of 0.5-inch diameter FBR mixed oxide fuel pellets

    International Nuclear Information System (INIS)

    Rasmussen, D.E.; Benecke, M.W.; McCord, R.B.

    1979-01-01

    Large diameter (0.535 inch) mixed oxide fuel pellets for Fast Breeder Reactor application were successfully fabricated by the cold-press-and-sinter technique. Enriched UO 2 , PuO 2 -UO 2 , and PuO 2 -ThO 2 compositions were fabricated into nominally 90% theoretical density pellets for the UO 2 and PuO 2 -UO 2 compositions, and 88% and 93% T.D. for the PuO 2 -ThO 2 compositions. Some processing adjustments were required to achieve satisfactory pellet quality and density. Furnace heating rate was reduced from 200 to 50 0 C/h for the organic binder burnout cycle for the large, 0.535-inch diameter pellets to eliminate pellet cracking during sintering. Additional preslugging steps and die wall lubrication during pressing were used to eliminate pressing cracks in the PuO 2 -ThO 2 pellets

  18. Health physics challenges involved with opening a "seventeen-inch" concrete waste vault.

    Science.gov (United States)

    Sullivan, Patrick T; Pizzulli, Michelle

    2005-05-01

    This paper describes the various activities involved with opening a sealed legacy "Seventeen-inch" concrete vault and the health physics challenges and solutions employed. As part of a legacy waste stream that was removed from the former Hazardous Waste Management Facility at Brookhaven National Laboratory, the "Seventeen-inch" concrete vault labeled 1-95 was moved to the new Waste Management Facility for ultimate disposal. Because the vault contained 239Pu foils with a total activity in excess of the transuranic waste limits, the foils needed to be removed and repackaged for disposal. Conventional diamond wire saws could not be used because of facility constraints, so this project relied mainly on manual techniques. The planning and engineering controls put in place enabled personnel to open the vault and remove the waste while keeping dose as low as reasonably achievable.

  19. Using a nitrilase for the surface modification of acrylic fibres.

    Science.gov (United States)

    Matamá, Teresa; Carneiro, Filipa; Caparrós, Cristina; Gübitz, Georg M; Cavaco-Paulo, Artur

    2007-03-01

    The surface of an acrylic fibre was modified with a commercial nitrilase (EC 3.5.5.1). The effect of fibre solvents and polyols on nitrilase catalysis efficiency and stability was investigated. The nitrilase action on the acrylic fabric was improved by the combined addition of 1 M sorbitol and 4% N, N-dimethylacetamide. The colour levels for samples treated with nitrilase increased 156% comparing to the control samples. When the additives were introduced in the treatment media, the colour levels increased 199%. The enzymatic conversion of nitrile groups into the corresponding carboxylic groups, on the fibre surface, was followed by the release of ammonia and polyacrylic acid. A surface erosion phenomenon took place and determined the "oscillatory" behaviour of the amount of dye uptake with time of treatment. These results showed that the outcome of the application of the nitrilase for the acrylic treatment is intimately dependent on reaction media parameters, such as time, enzyme activity and formulation.

  20. Nucleophilic Addition of Reactive Dyes on Amidoximated Acrylic Fabrics

    Science.gov (United States)

    El-Shishtawy, Reda M.; El-Zawahry, Manal M.; Abdelghaffar, Fatma; Ahmed, Nahed S. E.

    2014-01-01

    Seven reactive dyes judiciously selected based on chemical structures and fixation mechanisms were applied at 2% owf of shade on amidoximated acrylic fabrics. Amidoximated acrylic fabric has been obtained by a viable amidoximation process. The dyeability of these fabrics was evaluated with respect to the dye exhaustion, fixation, and colour strength under different conditions of temperature and dyeing time. Nucleophilic addition type reactive dyes show higher colour data compared to nucleophilic substitution ones. FTIR studies further implicate the binding of reactive dyes on these fabrics. A tentative mechanism is proposed to rationalize the high fixation yield obtained using nucleophilic addition type reactive dyes. Also, the levelling and fastness properties were evaluated for all dyes used. Excellent to good fastness and levelling properties were obtained for all samples irrespective of the dye used. The result of investigation offers a new method for a viable reactive dyeing of amidoximated acrylic fabrics. PMID:25258720

  1. Lightweight bonded acrylic facing at the Vitra VSL Factory

    Directory of Open Access Journals (Sweden)

    Matthias

    2013-12-01

    Full Text Available Corresponding author: Matthias Michel, E-mail: michel@imagine-structure.eu Acrylic glass is omnipresent in the industrialised world; but as a building material most architects, facade planners and engineers are still unfamiliar with this material. In most cases it is applied as a substitute for glass which leads to inappropriate joints and fixtures. During the years of the path toward the digital era, the authors were in the fortunate position to be involved in several unconventional glass and acrylic glass projects. On the basis of their most recent project, the facade of the Vitra VSL Factory by SANAA Architekten, they describe the development of a facade for which they chose acrylic glass not as a substitute for glass but rather as a conscious material choice. Since the entire facade is it was possible to apply the manufacturing technology of deep-drawing, allowing for very thin wall thicknesses.

  2. Nucleophilic addition of reactive dyes on amidoximated acrylic fabrics.

    Science.gov (United States)

    El-Shishtawy, Reda M; El-Zawahry, Manal M; Abdelghaffar, Fatma; Ahmed, Nahed S E

    2014-01-01

    Seven reactive dyes judiciously selected based on chemical structures and fixation mechanisms were applied at 2% of of shade on amidoximated acrylic fabrics. Amidoximated acrylic fabric has been obtained by a viable amidoximation process. The dyeability of these fabrics was evaluated with respect to the dye exhaustion, fixation, and colour strength under different conditions of temperature and dyeing time. Nucleophilic addition type reactive dyes show higher colour data compared to nucleophilic substitution ones. FTIR studies further implicate the binding of reactive dyes on these fabrics. A tentative mechanism is proposed to rationalize the high fixation yield obtained using nucleophilic addition type reactive dyes. Also, the levelling and fastness properties were evaluated for all dyes used. Excellent to good fastness and levelling properties were obtained for all samples irrespective of the dye used. The result of investigation offers a new method for a viable reactive dyeing of amidoximated acrylic fabrics.

  3. Preparation and Characterization of Acrylic Primer for Concrete Substrate Application

    Directory of Open Access Journals (Sweden)

    El-Sayed Negim

    2016-01-01

    Full Text Available This study dealt with the properties of acrylic primer for concrete substrate using acrylic syrup, made from a methyl methacrylate monomer solution of terpolymers. Terpolymer systems consisting of methyl methacrylate (MMA, 2-ethylhexyl acrylate (2-EHA, and methacrylic acid (MAA with different chemical composition ratios of MMA and 2-EHA were synthesized through bulk polymerization using azobisisobutyronitrile (AIBN as initiator. The terpolymer composition is characterized by FTIR, 1H NMR, DSC, TGA, and SEM. The glass transition temperature and the thermal stability increased with increasing amounts of MMA in the terpolymer backbone. The effect of chemical composition of terpolymers on physicomechanical properties of primer films was investigated. However, increasing the amount of MMA in terpolymer backbone increased tensile and contact angle of primer films while elongation at break, water absorption, and bond strength are decreased. In particular, the primer syrup containing 65% 2-EHA has good bonding strength with concrete substrate around 1.1 MPa.

  4. Ionizing radiation method for forming acrylic pressure sensitive adhesives and coated substrates

    International Nuclear Information System (INIS)

    Dowbenko, R.; Christenson, R.M.

    1975-01-01

    Pressure-sensitive adhesive having improved adhesive properties are formed by subjecting a mixture comprising a monomer selected from the group consisting of alkyl acrylates, hydroxyalkyl acrylates, alkoxyalkyl acrylates, cyanoalkyl acrylates, alkyl methacrylates, hydroxyalkyl methacrylates, alkoxyalkyl methacrylates, cyanoalkyl methacrylates, N-alkoxymethylacrylamides, and N-alkoxymethylmethacrylamides, and a homopolymer or copolymer selected from the group consisting of polymers of alkyl acrylates, hydroxyalkyl acrylates, alkoxyalkyl acrylates, cyanoalkyl acrylates, alkyl methacrylates, hydroxyalkyl methacrylates, alkoxyalkyl methacrylates, cyanoalkyl methacrylates, acrylamide, methacrylamide, N-(substituted alkyl) acrylamides, N-(substituted alkyl) methacrylamides, alkyl acrylamides, alkyl methacrylamides, and N-alkoxymethylacrylamides and N-alkoxymethylmethacrylamides to ionizing irradiation. The adhesive material finds utility as binding resins in laminates, coatings on substrates, and as film adhesives. (U.S.)

  5. Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins

    Directory of Open Access Journals (Sweden)

    Nour M. Ajaj-ALKordy

    2014-01-01

    Conclusion: Within the limitations of this study, it can be concluded that the high-impact acrylic resin is a suitable denture base material for patients with clinical fracture of the acrylic denture.

  6. Schlesinger's Telescope: A Brief History of the Yale 26-inch Refractor

    Science.gov (United States)

    van Altena, W. F.; Hoffleit, E. D.

    2003-08-01

    Frank Schlesinger began planning for the establishment of a southern observatory when he arrived at Yale in 1920. After discussing the possibility of a location in Auckland, New Zealand and gathering site survey observations for a four-month period, he decided to select a site in Johannesburg, South Africa. A large photographically corrected 26-inch objective was ground, polished and completed by James McDowell in 1923, while the telescope was built largely in the Yale shops in New Haven. Schlesinger left New Haven in 1924 with the lens, and the telescope followed shortly thereafter. Installation of the 26-inch refractor was completed in early June and dedicated by the Prince of Wales on June 22, 1924. The principal observational program for the 26-inch refractor was the determination of parallaxes of the bright stars and it was continued until 1952, when the telescope was moved to Mt. Stromlo due to the deteriorating sky conditions in Johannesburg. The parallax program continued at Mt. Stromlo until 1963 when the telescope was donated to the Commonwealth Observatory and the Yale-Columbia project moved to Argentina, Columbia having joined with Yale in 1943. Approximately 70,000 plates were taken with the refractor for the parallax programs and about 2,000 stellar parallaxes determined. The Schlesinger 26-inch refractor was destroyed by a firestorm on January 18, 2003, along with the other telescopes on Mount Stromlo, the workshop, library and many of the residences. This event was a sad ending to a telescope that played a major role in defining our knowledge of the distances, motions and masses of the brighter stars during the first half of the 20th century.

  7. Design of a 18F production system at ORNL 86-inch cyclotron

    International Nuclear Information System (INIS)

    Shaeffer, M.C.; Barreto, F.; Datesh, J.R.; Goldstein, B.R.

    1977-01-01

    A target system for the production of 18 F by proton bombardment of H 2 18 O was designed for the ORNL 86-inch cyclotron facility. The system consists of concentric titanium and aluminum cylinders. Oxygen-18-enriched H 2 O circulates through the inner titanium cylinder and through an external heat exchanger with cooling water flowing in the annulus. Yields of 5.0 curies are expected for a 250-μA proton beam current and 24-min irradiation time

  8. Colour stability of heat and cold cure acrylic resins.

    Science.gov (United States)

    Bohra, Pavan Kumar; Ganesh, P R; Reddy, Madan Mohan; Ebenezar, A V Rajesh; Sivakumar, G

    2015-01-01

    To evaluate the colour stability of heat and cold cure acrylic resins under simulated oral conditions with different colorants. Three different brands of heat cure acrylic resin and two rapid cure auto polymerizing acrylic resin of commercial products such as Trevelon Heat Cure (THC), DPI Heat cure (DHC), Pyrax Heat Cure (PHC), DPI Cold cure (DCC) and Acralyn-R-Cold cure (ACC) have been evaluated for discoloration and colour variation on subjecting it to three different, commonly employed food colorants such as Erythrosine, Tartarizine and Sunset yellow. In order to simulate the oral condition the food colorants were diluted with artificial saliva to the samples taken up for the study. These were further kept in an incubator at 37°C ± 1°C. The UV-visible spectrophotometer has been utilized to evaluate the study on the basis of CIE L* a* b* system. The prepared samples for standard evaluation have been grouped as control group, which has been tested with a white as standard, which is applicable for testing the colour variants. The least colour changes was found to be with Sunset Yellow showing AE* value of 3.55 with heat cure acrylic resin branded as PHC material and the highest colour absorption with Tartarizine showing AE* value of 12.43 in rapid cure autopolymerzing acrylic resin material branded as ACC material. ACC which is a self cure acrylic resin shows a higher colour variation to the tartarizine food coloration. There were not much of discoloration values shown on the denture base resins as the food colorants are of organic azodyes.

  9. Technology and the use of acrylics for provisional dentine protection.

    Science.gov (United States)

    Kapusevska, Biljana; Dereban, Nikola; Popovska, Mirjana; Nikolovska, Julijana; Radojkova Nikolovska, Vеrа; Zabokova Bilbilova, Efka; Mijoska, Aneta

    2013-01-01

    Acrylics are compounds polymerized from monomers of acrylic, metacrylic acid or acrylonitrates. The purpose of this paper is to present the technology and use of acrylics for provisional dentine protection in the practice of dental prosthodontics. For this reason, we followed 120 clinical cases from the everyday clinical practice, divided into 4 groups of 30 patients who needed prosthetic reconstruction. The first group included cases in which we applied celluloid crowns for dentine protection, for the second group we used acrylic teeth from a set of teeth for complete dentures; in the third and fourth groups the fabrication was done with the system of an impression matrix and the acrylic resin block technique respectively. In all the examined patients, the gingival index by Silness and Loe and the vitality of the dental pulp were verified clinically, after preparation and 8 days from the placement of the provisional crown. The value for dental sensitivity measured after preparation was 2.59, and 8 days after the placement of the provisional crown it bwas 3.1. From these results we can conclude that after the 8th day from the placement of the provisional crown, there was an adaptation period, characterized by a decrease in the painful sensations. The value of the Silness and Loe gingival index measured after the preparation was 1.34, and 8 days from the placement of the provisional crown was 0.94. The results inclined us to the fact that the provisional acrylic crowns facilitated the reparation of the periodontal tissue.

  10. Water Column Sonar Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The collection and analysis of water column sonar data is a relatively new avenue of research into the marine environment. Primary uses include assessing biological...

  11. The development of epoxidised palm oil acrylate (EPOLA) and its applications

    International Nuclear Information System (INIS)

    Mohd Hilmi Mahmood

    1993-01-01

    The topics are discussed briefly. Acrylated palm oil is prepared through acrylation process, whereby, acrylic acid is introduced into oxirane group of the EPOP (epoxidised palm oil products), EPOLA (epoxidised palm oil products acrylate) was found curable when subjected to UV (ultrviolet) light giving soft coatings. EPOLA is used as radiation curable filler/sealer, radiation curable pressure sensitive adhesives and satisfactorily be coated on wood substrates (rubberwood parquets)

  12. Nanopigmented Acrylic Resin Cured Indistinctively by Water Bath or Microwave Energy for Dentures

    OpenAIRE

    L. S. Acosta-Torres; M. C. Arenas; R. E. Nuñez­-Anita; F. H. Barceló-Santana; C. A. Álvarez-Gayosso; J. Palacios-Alquisira; J. de la Fuente-Hernández; Marcos Cajero-Juárez; V. M. Castaño

    2014-01-01

    The highlight of this study was the synthesis of nanopigmented poly(methyl methacrylate) nanoparticles that were further processed using a water bath and/or microwave energy for dentures. The experimental acrylic resins were physicochemically characterized, and the adherence of Candida albicans and biocompatibility were assessed. A nanopigmented acrylic resin cured by a water bath or by microwave energy was obtained. The acrylic specimens possess similar properties to commercial acrylic resin...

  13. Behavior of Confined Columns under Different Techniques

    OpenAIRE

    Mostafa Osman; Ata El-Kareim Shoeib Soliman

    2015-01-01

    Since columns are the most important elements of the structures, failure of one column in a critical location can cause a progressive collapse. In this respect, the repair and strengthening of columns is a very important subject to reduce the building failure and to keep the columns capacity. Twenty columns with different parameters is tested and analysis. Eleven typical confined reinforced concrete (RC) columns with different types of techniques are assessment. And also,...

  14. LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  15. Application of ftir in the determination of acrylate content in poly(sodium acrylate-co-acrylamide superabsorbent hydrogels

    Directory of Open Access Journals (Sweden)

    Antônio Sávio G. Magalhães

    2012-01-01

    Full Text Available Hydrogels have been prepared by free-radical solution copolymerization of acrylamide and sodium acrylate (NaAc, with molar ratio ranging from 25/75 to 80/20, respectively, using methylene bisacrylamide as the crosslinking agent. A FTIR spectroscopy procedure to determine the acrylate/acrylamide ratio in these hydrogels was proposed based on absorbance at 1410 cm-1 (nCOO- and 2940 cm-1 (nCH and nCH2. A straight line with a good linear correlation coefficient (0.998 was obtained by plotting the acrylate content (Ac% versus relative absorbance (Arel = A1410/A2940. Results were confirmed by the amount of sodium cation released in acid medium determined by atomic absorption spectrometry.

  16. Effects of Novel Structure Bonding Materials on Properties of Aeronautical Acrylic

    Directory of Open Access Journals (Sweden)

    LI Zhisheng

    2017-06-01

    Full Text Available Novel structure bonding materials, J-351 epoxy adhesive film with low curing temperature and liquid modified acrylate SY-50s adhesive were chosen and characterized. The effects of adhesives on the mechanical properties of acrylic were studied. The results reveal that both adhesives have excellent bonding properties to acrylic. The stress-solvent crazing value of J-351 is higher than that of SY-50s. With the application of adhesive on the surface, mechanical properties of acrylic are declined. Casting acrylic shows more drastic decline than that of oriented acrylic. Through the characterization of fracture surface, we find that fracture of tensile sample derives from the side with adhesive. Mechanical properties of acrylic are more sensitive to SY-50s, because the liquid adhesive presents integrate bonding interface with acrylic. The interface between J-351 and acrylic is clear, making acrylic insensitive to J-351 film. Edge attachment strength of samples bonded with J-351 are higher than that of samples bonded with SY-50s due to the effects of adhesives on acrylic. J-351 epoxy adhesive film presents preferable application performance in the structure bonding of aeronautical acrylic.

  17. 40 CFR 180.1162 - Acrylate polymers and copolymers; exemption from the requirement of a tolerance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Acrylate polymers and copolymers... RESIDUES IN FOOD Exemptions From Tolerances § 180.1162 Acrylate polymers and copolymers; exemption from the requirement of a tolerance. (a) Acrylate polymers and copolymers are exempt from the requirement of a...

  18. 40 CFR 721.10147 - Acrylate derivative of alkoxysilylalkane ester and mixed metal oxides (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Acrylate derivative of... SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.10147 Acrylate derivative of... reporting. (1) The chemical substance identified generically as acrylate derivative of alkoxysilylalkane...

  19. The George C. Marshall Space Flight Center's 14 X 14-Inch Trisonic Wind Tunnel: A Historical Perspective

    Science.gov (United States)

    Springer, A.

    1994-01-01

    A history of the National Aeronautics and Space Administration (NASA) George C. Marshall Space Flight Center's (MSFC) 14 x 14-Inch Trisonic Wind Tunnel is presented. Its early and continuing role in the United States space program is shown through highlights of the tunnel's history and the major programs tested in the tunnel over the past 40 years. The 14-Inch Tunnel has its beginning with the Army in the late 1950's under the Army Ballistic Missile Agency (ABMA). Such programs as the Redstone, Jupiter, Pershing, and early Saturn were tested in the 14-Inch Tunnel in the late 1950's. America's first launch vehicle, the Jupiter C, was designed and developed using the 14-Inch Wind Tunnel. Under NASA, the 14-Inch Wind Tunnel has made large contributions to the Saturn, Space Transportation System, and future launch vehicle programs such as Shuttle-C and the National Launch System. A technical description of the tunnel is presented for background information on the type and capabilities of the 14-Inch Wind Tunnel. The report concludes in stating: the 14-Inch Wind Tunnel as in speed of sound; transonic, at or near the speed of sound the past, will continue to play a large but unseen role in he development of America's space program.

  20. Radiotracer Imaging of Sediment Columns

    Science.gov (United States)

    Moses, W. W.; O'Neil, J. P.; Boutchko, R.; Nico, P. S.; Druhan, J. L.; Vandehey, N. T.

    2010-12-01

    Nuclear medical PET and SPECT cameras routinely image radioactivity concentration of gamma ray emitting isotopes (PET - 511 keV; SPECT - 75-300 keV). We have used nuclear medical imaging technology to study contaminant transport in sediment columns. Specifically, we use Tc-99m (T1/2 = 6 h, Eγ = 140 keV) and a SPECT camera to image the bacteria mediated reduction of pertechnetate, [Tc(VII)O4]- + Fe(II) → Tc(IV)O2 + Fe(III). A 45 mL bolus of Tc-99m (32 mCi) labeled sodium pertechnetate was infused into a column (35cm x 10cm Ø) containing uranium-contaminated subsurface sediment from the Rifle, CO site. A flow rate of 1.25 ml/min of artificial groundwater was maintained in the column. Using a GE Millennium VG camera, we imaged the column for 12 hours, acquiring 44 frames. As the microbes in the sediment were inactive, we expected most of the iron to be Fe(III). The images were consistent with this hypothesis, and the Tc-99m pertechnetate acted like a conservative tracer. Virtually no binding of the Tc-99m was observed, and while the bolus of activity propagated fairly uniformly through the column, some inhomogeneity attributed to sediment packing was observed. We expect that after augmentation by acetate, the bacteria will metabolically reduce Fe(III) to Fe(II), leading to significant Tc-99m binding. Imaging sediment columns using nuclear medicine techniques has many attractive features. Trace quantities of the radiolabeled compounds are used (micro- to nano- molar) and the half-lives of many of these tracers are short (Image of Tc-99m distribution in a column containing Rifle sediment at four times.

  1. Performance of waterborne acrylic surface coatings on wood ...

    Indian Academy of Sciences (India)

    1, February 2011, pp. 113–119. c Indian Academy of Sciences. Performance of waterborne acrylic surface coatings on wood impregnated with Cu-ethanolamine preservatives. M HUMAR, M PAVLI ˇC, D ŽLINDRA†, M TOMAŽI ˇC†† and M PETRI ˇC. ∗. Department of Wood Science and Technology, University of Ljubljana, ...

  2. Effect of acrylic acid on the properties of polyvinylpyrrolidone ...

    African Journals Online (AJOL)

    Hydrogels based on polyvinylpyrrolidone (PVP) networks grafted with acrylic acid (AAc) was prepared by using γ-rays from a Co-60 source at room temperature. The parameters like effect of radiation dose and concentration of AAc were studied. The properties such as gel content, swelling behavior and thermal stability ...

  3. Test of a large size acrylic scintillation counter

    International Nuclear Information System (INIS)

    Bertino, M.; De Zorzi, G.; Zanello, D.

    1984-01-01

    We have tested the behaviour of an acrylic scintillator measuring the attenuation length and the time resolution of a 7.8 m long counter. On a small sample the photon yield relative to the NE 110 plastic has been measured. (orig.)

  4. Hydrogen Bonding Interaction between 1-Propanol and Acrylic ...

    African Journals Online (AJOL)

    The association between 1-propanol and acrylic esters (methyl methacrylate, ethyl methacrylate and butyl methacrylate) in non-polar solvents, viz. n-heptane, CCl4, and benzene has been investigated by means of FTIR spectroscopy. The formation constants of the 1:1 complexes have been calculated using Nash's method.

  5. Studies on thin film materials on acrylics for optical applications

    Indian Academy of Sciences (India)

    Unknown

    Antireflection coatings made on PMMA substrate using Substance2 (H2) and SiO2 combination showed very fine cracks when observed under microscope. Optical performance of the coatings has been explained with the help of optical micrographs. Keywords. Coatings on acrylics; dielectric thin films; optical coatings; low ...

  6. Comparison of classical dermatoscopy and acrylic globe magnifier dermatoscopy

    DEFF Research Database (Denmark)

    Lorentzen, Henrik F; Eefsen, Rikke Løvendahl; Weismann, Kaare

    2008-01-01

    % confidence interval 83-97%). Sensitivity for melanoma, benign melanocytic naevi and basal cell carcinoma was 100%, 98% and 85%, respectively. Specificity was 95%, 94% and 100% for melanoma, naevi and basal cell carcinoma. Acrylic globe dermatoscopy enables a diagnostic accuracy similar to epiluminescence...

  7. Microstructure and properties of styrene acrylate polymer cement concrete

    NARCIS (Netherlands)

    Undetermined, U.

    1995-01-01

    The paper systematically describes the evolution of the microstructure of a styrene acrylate polymer cement concrete in relation to its mechanical properties and durability. The results presented and discussed at the present paper involve the interaction of the polymer dispersion with portland

  8. Lightweight bonded acrylic facing at the Vitra VSL Factory

    NARCIS (Netherlands)

    Michel, M.T.; Techen, H.

    2013-01-01

    Acrylic glass is omnipresent in the industrialised world; but as a building material most architects, facade planners and engineers are still unfamiliar with this material. In most cases it is applied as a substitute for glass which leads to inappropriate joints and fixtures. During the years of the

  9. Investigation into nanocellulosics versus acacia reinforced acrylic films

    Science.gov (United States)

    Yunqiao Pu; Jianguo Zhang; Thomas Elder; Yulin Deng; Paul Gatenholm; Arthur J. Ragauskas

    2007-01-01

    Three closely related cellulosic acrylic latex films were prepared employing acacia pulp fibers, cellulose whiskers and nonocellulose balls and their respective strength properties were determined. Cellulose whisker reinforced composites had enhanced strength properties compared to the acacia pulp and nanoball composites. AFM analysis indicated that the cellulose...

  10. Simultaneous production of biobased styrene and acrylates using ethenolysis

    NARCIS (Netherlands)

    Spekreijse, J.; Notre, le J.E.L.; Haveren, van J.; Scott, E.L.; Sanders, J.P.M.

    2012-01-01

    Phenylalanine (1), which could be potentially obtained from biofuel waste streams, is a precursor of cinnamic acid (2) that can be converted into two bulk chemicals, styrene (3) and acrylic acid (4), via an atom efficient pathway. With 5 mol% of Hoveyda–Grubbs 2nd generation catalyst, 1 bar of

  11. Bond strength between acrylic resin and maxillofacial silicone

    Directory of Open Access Journals (Sweden)

    Marcela Filié Haddad

    2012-12-01

    Full Text Available The development of implant dentistry improved the possibilities of rehabilitation with maxillofacial prosthesis. However, clinically it is difficult to bond the silicone to the attachment system. OBJECTIVES: This study aimed to evaluate the effect of an adhesive system on the bond strength between acrylic resin and facial silicone. MATERIAL AND METHODS: A total of 120 samples were fabricated with auto-polymerized acrylic resin and MDX 4-4210 facial silicone. Both materials were bonded through mechanical retentions and/or application of primers (DC 1205 primer and Sofreliner primer S and adhesive (Silastic Medical Adhesive Type A or not (control group. Samples were divided into 12 groups according to the method used to attach the silicone to the acrylic resin. All samples were subjected to a T-peel test in a universal testing machine. Failures were classified as adhesive, cohesive or mixed. The data were evaluated by the analysis of variance (ANOVA and the Tukey's HSD test (α=.05. RESULTS: The highest bond strength values (5.95 N/mm; 3.07 N/mm; 4.75 N/mm were recorded for the samples that received a Sofreliner primer application. These values were significantly higher when the samples had no scratches and did not receive the application of Silastic Medical Adhesive Type A. CONCLUSIONS: The most common type of failure was adhesive. The use of Sofreliner primer increased the bond strength between the auto-polymerized acrylic resin and the Silastic MDX 4-4210 facial silicone.

  12. Oil-acrylic hybrid latexes as binders for waterborne coatings

    NARCIS (Netherlands)

    Hamersveld, van E.M.S.; Es, van J.; German, A.L.; Cuperus, F.P.; Weissenborn, P.; Hellgren, A.C.

    1999-01-01

    The combination of the characteristics of oil, or alkyd, emulsions and acrylic latexes in a waterborne binder has been the object of various studies in the past. Strategies for combining the positive properties of alkyds, e.g. autoxidative curing, gloss and penetration in wood, with the fast drying

  13. Antimicrobial activity of poly(acrylic acid) block copolymers.

    Science.gov (United States)

    Gratzl, Günther; Paulik, Christian; Hild, Sabine; Guggenbichler, Josef P; Lackner, Maximilian

    2014-05-01

    The increasing number of antibiotic-resistant bacterial strains has developed into a major health problem. In particular, biofilms are the main reason for hospital-acquired infections and diseases. Once formed, biofilms are difficult to remove as they have specific defense mechanisms against antimicrobial agents. Antimicrobial surfaces must therefore kill or repel bacteria before they can settle to form a biofilm. In this study, we describe that poly(acrylic acid) (PAA) containing diblock copolymers can kill bacteria and prevent from biofilm formation. The PAA diblock copolymers with poly(styrene) and poly(methyl methacrylate) were synthesized via anionic polymerization of tert-butyl acrylate with styrene or methyl methacrylate and subsequent acid-catalyzed hydrolysis of the tert-butyl ester. The copolymers were characterized via nuclear magnetic resonance spectroscopy (NMR), size-exclusion chromatography (SEC), Fourier transform infrared spectroscopy (FTIR), elemental analysis, and acid-base titrations. Copolymer films with a variety of acrylic acid contents were produced by solvent casting, characterized by atomic force microscopy (AFM) and tested for their antimicrobial activity against Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. The antimicrobial activity of the acidic diblock copolymers increased with increasing acrylic acid content, independent of the copolymer-partner, the chain length and the nanostructure. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Calibration of an Electron Linear Accelerator using an acrylic puppet

    International Nuclear Information System (INIS)

    Guzman C, C.S.; Picon C, C.

    1998-01-01

    The finality of this work is to find the dose for electron beams using acrylic puppets and inter comparing with the measurements in water, found also its respective conversion factor. With base in this, its may be realize interesting measurements for the good performance of a linear accelerator and special clinical treatments in less time. (Author)

  15. Performance of waterborne acrylic surface coatings on wood ...

    Indian Academy of Sciences (India)

    Two waterborne acrylic coatings were applied on spruce wood, impregnated with two copperethanolamine containing preservatives (CuE and CuEQ), one of them (CuEQ) containing a boron compound, octanoic acid and a quaternary ammonium compound as additives. Lower contact angles and deeper penetration of both ...

  16. Synthesis and characterization of poly(2-ethylhexyl acrylate ...

    Indian Academy of Sciences (India)

    Abstract. This investigation reports a comparative study of poly(2-ethylhexyl acrylate) (PEHA) prepared via atom transfer radical polymerization (ATRP), reverse atom transfer radical polymerization (RATRP) and con- ventional free radical polymerization (FRP). The molecular weights and the molecular weight distributions.

  17. Decarboxylation-based traceless linking with aroyl acrylic acids

    DEFF Research Database (Denmark)

    Nielsen, John

    1998-01-01

    beta-Keto carboxylic acids are known to decarboxylate readily. In our pursuit to synthesize beta-indolinyl propiophenones, we have exploited this chemistry as a mean of establishing a traceless handle. 2-Aroyl acrylic acids have been esterified to a trityl resin, after which Michael-type addition...

  18. Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns?

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Dennis, Gary R; Shalliker, R Andrew

    2015-08-19

    Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 μm particles. The data showed that reaction loops beyond 100 μL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column. Copyright © 2015. Published by Elsevier B.V.

  19. Nanopigmented Acrylic Resin Cured Indistinctively by Water Bath or Microwave Energy for Dentures

    Directory of Open Access Journals (Sweden)

    L. S. Acosta-Torres

    2014-01-01

    Full Text Available The highlight of this study was the synthesis of nanopigmented poly(methyl methacrylate nanoparticles that were further processed using a water bath and/or microwave energy for dentures. The experimental acrylic resins were physicochemically characterized, and the adherence of Candida albicans and biocompatibility were assessed. A nanopigmented acrylic resin cured by a water bath or by microwave energy was obtained. The acrylic specimens possess similar properties to commercial acrylic resins, but the transverse strength and porosity were slightly improved. The acrylic resins cured with microwave energy exhibited reduced C. albicans adherence. These results demonstrate an improved noncytotoxic material for the manufacturing of denture bases in dentistry.

  20. Properties of 8-inch photomultiplier tubes for a large volume imaging water Cerenkov detector

    International Nuclear Information System (INIS)

    Oehler, Ch.

    1996-01-01

    In the Institut fuer Kernphysik I conceptional studies for a possible succession project for the KARMEN-ν-detector are performed. This design studies propose to build a large volume 1300 t imaging water Cerenkov detector. The main goal of this experiment will be the investigation of ν-e - -scattering in the medium energy range up to 50 MeV. The sensitive surface of this detector will be instrumented with about 3000 8-inch photomultiplier tubes (PMT) providing a coverage of 20%. In the framework of this detector design, studies of the properties of hemispherical 8-inch phototubes have been investigated in this work. The topic was to optimise the quality of the important PMT properties like time- and energy-resolution which are crucial to achieve the required spatial and angular resolutions. A second task of this work was to construct a test facility for the PMT, with the possibility to test large quantities. Monte Carlo calculations show that the required detector resolutions of σ E /E(E e ≤50 MeV)=5.2%+47%/√E, σ t (E e ∼30 MeV)=0.6 ns, σ x (E e ∼30 MeV)=13 cm, σ Θ (E e ∼30 MeV)=20 , can be achieved if the phototubes have a transit-time spread less than 1 ns. Up to now, two different 8-inch tubes are available and have been tested, the HAMAMATSU R5912 and the EMI 9353. (orig.)

  1. Anionic polymerization of acrylates. XIV. Synthesis of MMA/acrylate block copolymers initiated with ester-enolate/tert-alkoxide complex

    Czech Academy of Sciences Publication Activity Database

    Vlček, Petr; Čadová, Eva; Kříž, Jaroslav; Látalová, Petra; Janata, Miroslav; Toman, Luděk; Masař, Bohumil

    2005-01-01

    Roč. 46, č. 14 (2005), s. 4991-5000 ISSN 0032-3861 Institutional research plan: CEZ:AV0Z4050913 Keywords : ligated anionic polymerization * (meth)acrylates * block copolymers Subject RIV: CD - Macromolecular Chemistry Impact factor: 2.849, year: 2005

  2. Photometric Typing Analyses of Three Young Supernovae with the Robotic Palomar 60-Inch Telescope

    OpenAIRE

    Rajala, Anne M.; Fox, Derek B.; Gal-Yam, Avishay; Leonard, Douglas C.; Soderberg, Alicia M.; Kulkarni, S. R.; Cenko, S. Bradley; Moon, Dae-Sik; Harrison, Fiona A.

    2004-01-01

    We present photometric typing analyses of three young supernovae observed with the Robotic 60-inch Telescope at Palomar Observatory (P60). This represents the first time that such photo-typing has been attempted, in a blind fashion, on newly-discovered supernovae. For one of the target supernovae, SN2004cs, our photometry provided the first constraint on the SN type, which we predicted would be type Ia. To the contrary, however, our subsequent Keck spectroscopy shows it to be an unusual type ...

  3. Nanomanipulation of 2 inch wafer fabrication of vertically aligned carbon nanotube arrays by nanoimprint lithography

    DEFF Research Database (Denmark)

    Bu, Ian Y. Y.; Eichhorn, Volkmar; Carlson, Kenneth

    2011-01-01

    Carbon nanotube (CNT) arrays are typically defined by electron beam lithography (EBL), and hence limited to small areas due to the low throughput. To obtain wafer‐scale fabrication we propose large area thermal nanoimprint lithography (NIL). A 2‐inch stamp master is defined using EBL for subsequent......, efficient production of wafer‐scale/larger arrays of CNTs has been achieved. The CNTs have been deposited by wafer‐scale plasma enhanced chemical vapour deposition (PECVD) of C2H2/NH3. Substrates containing such nanotubes have been used to automate nanorobotic manipulation sequences of individual CNTs...

  4. First thin AC-coupled silicon strip sensors on 8-inch wafers

    Energy Technology Data Exchange (ETDEWEB)

    Bergauer, T., E-mail: thomas.bergauer@oeaw.ac.at [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Dragicevic, M.; König, A. [Institute of High Energy Physics of the Austrian Academy of Sciences, Nikolsdorfer Gasse 18, 1050 Wien (Vienna) (Austria); Hacker, J.; Bartl, U. [Infineon Technologies Austria AG, Siemensstrasse 2, 9500 Villach (Austria)

    2016-09-11

    The Institute of High Energy Physics (HEPHY) in Vienna and the semiconductor manufacturer Infineon Technologies Austria AG developed a production process for planar AC-coupled silicon strip sensors manufactured on 200 μm thick 8-inch p-type wafers. In late 2015, the first wafers were delivered featuring the world's largest AC-coupled silicon strip sensors. Detailed electrical measurements were carried out at HEPHY, where single strip and global parameters were measured. Mechanical studies were conducted and the long-term behavior was investigated using a climate chamber. Furthermore, the electrical properties of various test structures were investigated to validate the quality of the manufacturing process.

  5. Elemental Water Impact Test: Phase 2 36-Inch Aluminum Tank Head

    Science.gov (United States)

    Vassilakos, Gregory J.

    2014-01-01

    Spacecraft are being designed based on LS-DYNA simulations of water landing impacts. The Elemental Water Impact Test (EWIT) series was undertaken to assess the accuracy of LS-DYNA water impact simulations. EWIT Phase 2 featured a 36-inch aluminum tank head. The tank head was outfitted with one accelerometer, twelve pressure transducers, three string potentiometers, and four strain gages. The tank head was dropped from heights of 1 foot and 2 feet. The focus of this report is the correlation of analytical models against test data. As a measure of prediction accuracy, peak responses from the baseline LS-DYNA model were compared to peak responses from the tests.

  6. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  7. High-Volume Production of Lightweight, Multi-Junction Solar Cells Using 6-inch GaAs, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In the proposed Phase II program, we will transition MicroLink's 6-inch epitaxial lift-off (ELO) solar cell fabrication process into a manufacturing platform capable...

  8. Stand Development 25 Years after a 9.0-inch Diameter-Limit First Cutting In Appalachian Hardwoods

    Science.gov (United States)

    H. Clay Smith; N. I. Lamson

    1977-01-01

    This report is a case history of stand development 25 years after a 9.0-inch diameter-limit cutting in a primarily second growth 40- to 45-year-old Appalachian hardwood stand. Some old residual trees from the early 1900 logging era were scattered throughout the stand. In 1950, a 9.0-inch diameter-limit cutting removed 8,650 board feet per acre and reduced the basal...

  9. Recommendations for protecting against failure by brittle fracture: Category II and III ferritic steel shipping containers with wall thickness greater than four inches

    International Nuclear Information System (INIS)

    Schwartz, M.W.; Fischer, L.E.

    1996-08-01

    This report provides criteria for selecting ferritic steels that would prevent brittle fracture in Category II and III shipping containers with wall thickness greater than 4 inches. These methods are extensions of those previously used for Category II and III containers less than 4 inches thick and Category I containers more than 4 inches thick

  10. A new alignment procedure for the South African Astronomical Observatory's 74-inch telescope

    Science.gov (United States)

    Crause, Lisa A.; Booth, John A.; Doss, David; Loubser, Egan; O'Connor, James E.; Sass, Craig; Sickafoose, Amanda A.; Worters, Hannah L.

    2016-07-01

    Considerable effort has gone into improving the performance and reliability of the SAAO's 74-inch telescope. This included replacing the telescope encoders, refining the pointing model and increasing the telescope throughput. The latter involved re-aluminising the primary and formulating a procedure to ensure optimal alignment of the telescope mirrors. To this end, we developed the necessary hardware and techniques to ensure that such alignment is achieved and maintained, particularly following re-aluminising of the mirrors. In essence, the procedure involves: placing a Taylor Hobson Alignment Telescope on the mechanical rotation axis of the 74-inch (which we define to be the optical axis, since the Cassegrain instruments attach to the associated turntable), then adjusting the tip/tilt of the secondary mirror to get it onto that axis and, lastly, adjusting the tip/tilt of the primary mirror to eliminate coma. An eyepiece (or wavefront camera) is installed at the Cassegrain port for this final step since comatic star images indicate the need to tip/tilt the primary mirror to align it to the secondary. Tuning out any brightness gradients seen in an out-of-focus image of a bright star may also be used for feedback when adjusting the tip/tilt of the primary mirror to null coma.

  11. A PROTOTYPE FOUR INCH SHORT HYDRIDE (FISH) BED AS A REPLACEMENT TRITIUM STORAGE BED

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.; Estochen, E.; Shanahan, K.; Heung, L.

    2011-02-23

    The Savannah River Site (SRS) tritium facilities have used 1st generation (Gen1) metal hydride storage bed assemblies with process vessels (PVs) fabricated from 3 inch nominal pipe size (NPS) pipe to hold up to 12.6 kg of LaNi{sub 4.25}Al{sub 0.75} metal hydride for tritium gas absorption, storage, and desorption for over 15 years. The 2nd generation (Gen2) of the bed design used the same NPS for the PV, but the added internal components produced a bed nominally 1.2 m long, and presented a significant challenge for heater cartridge replacement in a footprint limited glove-box. A prototype 3rd generation (Gen3) metal hydride storage bed has been designed and fabricated as a replacement candidate for the Gen2 storage bed. The prototype Gen3 bed uses a PV pipe diameter of 4 inch NPS so the bed length can be reduced below 0.7 m to facilitate heater cartridge replacement. For the Gen3 prototype bed, modeling results show increased absorption rates when using hydrides with lower absorption pressures. To improve absorption performance compared to the Gen2 beds, a LaNi{sub 4.15}Al{sub 0.85} material was procured and processed to obtain the desired pressure-composition-temperature (PCT) properties. Other bed design improvements are also presented.

  12. Artist autonomy in a digital era: The case of Nine Inch Nails

    Directory of Open Access Journals (Sweden)

    Steven C. Brown

    2012-09-01

    Full Text Available A 2009 presentation by Michael Masnick (CEO and founder of insight company Floor64 entitled ‘How Trent Reznor and Nine Inch Nails represent the Future of the Music Business’ brought the success of the business models employed by Reznor in distributing Nine Inch Nails’ music into the spotlight. The present review provides a comprehensive timeline of the band circa 2005-2010, evaluating the success of the distribution methods employed in accordance with Masnick’s (2009 proposed business model of connecting with fans and providing them with a reason to buy. The model is conceptualised in the wider context in which Reznor’s distribution methods take place (including a brief consideration of Radiohead’s much cited pay-what-you- want model, addressing the perceived gaps in the model by exploring the involvement of musical preferences; age and consumer purchasing behavior and fan worship. Implications are discussed concerning the applicability of the model for new and emerging bands.

  13. Separation Efficiency of Nagar Parker China Clay Using Two Inch Hydrocyclone

    Directory of Open Access Journals (Sweden)

    Abdul Ghani Pathan

    2013-01-01

    Full Text Available Performance efficiency of two inch hydrocyclone has been investigated, using the Nagar Parker china clay. Raw china clay was initially washed with tap water and -75 ?m size fraction was separated through wet sieving. Washed china clay of -75 ?m was used as feed sample in hydrocyclone tests. Solids concentration in slurry was kept as 2.5%. 45 tests were conducted with different combinations of pressure, vortex finder and spigot. Three sizes of spigot viz. 3.2, 2.2 and 1.5mm and three sizes of vortex finder viz. 7.00, 5.5 and 3.00mm were used. Hydrocyclone rig was operated at five different pressures viz. 20, 30, 40, 50 and 60 psi in conjunction with various combinations of vortex finder and spigot. Laser light scattering technique was used for particle size analysis of O/F (Overflow and U/F (Underflow products. Separation efficiency of the hydrocyclone, for various combinations of Vortex Finder, Spigot and operating pressure, was determined for two size fractions, i.e. less than ten micron and less than twenty micron, present in O/F and U/F products. From the results it was concluded that the best separation efficiency of 2 inch hydrocyclone is achieved by using the vortex finder of 7.0mm size and spigot of 1.5mm size. It was also concluded that the separation efficiency of the hydrocyclone decreases by increasing the pressure.

  14. Bubble columns : Structures or stability?

    NARCIS (Netherlands)

    Harteveld, W.K.

    2005-01-01

    The aim of the thesis is to contribute to the understanding of the hydrodynamics of the gravity driven bubbly flow that can be found in bubble columns. Special attention is paid to the large scale structures that have a strong impact on several key parameters such as the degree of mixing, mass and

  15. Influence of denture cleansers on the color stability of three types of denture base acrylic resin.

    Science.gov (United States)

    Hong, Guang; Murata, Hiroshi; Li, YingAi; Sadamori, Sinshuke; Hamada, Taizo

    2009-03-01

    Color stability is an important property of denture base acrylic resin. Color changes indicate aging or damaged dental materials. However, little information is available on the influence of denture cleansers on the color stability of acrylic resins. The purpose of this study was to determine the influence of denture cleansers on the color stability of 3 different types of acrylic resin. One heat-polymerized (HP) acrylic denture base resin (Acron), 1 autopolymerized (AP) hard direct reline acrylic resin (Denture Liner), and 1 visible-light-polymerized (VLP) hard direct reline acrylic resin (Tokuso Lite-Rebase) were evaluated. Five specimens of each material, 10 x 10 x 2 mm, were immersed in 1 of 9 commercial denture cleanser solutions or distilled water (control). Color changes were measured with a colorimeter and evaluated using the CIE L*a*b* colorimetric system. Data were analyzed using 1-way and 3-way ANOVA and the Student-Newman-Keuls test (alpha=.05). Significant differences (P<.05) were found among the acrylic resins and denture cleansers in terms of color change (DeltaE) produced after 365 days. The DeltaE values of all denture base acrylic resins increased with time. The DeltaE of the AP acrylic resin was larger than that of the other acrylic resins. The least discoloration was found with ZTC denture cleanser (acid type). The influence of alkaline peroxide-type denture cleanser (Steradent) on the color stability of HP acrylic resin and AP acrylic resin was significantly greater (P<.05) than that of the other cleansers. These results suggest that the color stability of denture base acrylic resins is influenced by polymerization type and the type of denture cleanser used.

  16. Laboratory and exterior durability of high performance acrylic sealants

    Energy Technology Data Exchange (ETDEWEB)

    Demarest, V.A.; Dionne, J.A.; Lertora, M.; Magnotta, J.R. [Rohm and Haas Co., Spring House, PA (United States). Caulk and Sealants Group

    1998-12-31

    This paper documents the laboratory and exterior durability of high performance, Class 25 acrylic sealants. Commercial silicone and polyurethane sealants are used as controls. Laboratory durability is evaluated by measuring sealant flexibility, tensile properties and ASTM C920 and ISO 11600 joint movement capabilities. Many of these properties are measured both before and after 2500 hours of Weather-Ometer exposure. Exterior durability is assessed by monitoring 2 to 15 year exterior exposures in moving joints in low rise commercial buildings of brick, aluminum and Exterior Insulation Finishing Systems (EIFS) construction. Both laboratory and exterior durability measurements indicate that high performance Class 25 acrylic sealants have good joint movement capabilities, excellent weatherability and aesthetics, and are generally able to maintain an effective seal to a variety of substrates after extended exterior exposure. They perform and test in a manner similar to other Class 25 sealants of alternative chemistries.

  17. Correlation in the mechanical properties of acrylic denture base resins.

    Science.gov (United States)

    Lee, Hae-Hyoung; Lee, Chung-Jae; Asaoka, Kenzo

    2012-02-03

    The aim of the present study was to measure various mechanical properties of acrylic denture base resins, including flexural modulus, flexural strength, fracture toughness, Barcol and Vickers hardness and their related properties, and to investigate correlations between different mechanical properties. Resin specimens were prepared according to manufacturers' recommended instructions. The mechanical properties were measured under specified standards. Data from the mechanical tests were examined using correlation tests. In general, the mean results for mechanical properties of each specimen group were differently ranked depending on the tested mechanical property. The flexural modulus value showed strong or reasonable positive correlation with those of proportional limit, flexural strength, and surface hardness. In contrast, fracture toughness revealed strong negative correlations with the flexural parameters and hardness values. Results of correlation tests for the different parameters can be used for estimation of mechanical performance of acrylic denture bases in clinical situation and for quality control purposes.

  18. Imparting permanent antimicrobial activity onto viscose and acrylic fabrics.

    Science.gov (United States)

    Mekewi, M; El-Sayed, A Atef; Amin, M S; Said, Hala I

    2012-05-01

    Viscose and acrylic fabrics were aminated to enhance metal chelation of Cu, Zn and Ni for the purpose of imparting fabrics antimicrobial activity against Escherichia coli and Staphylococcus aureus. Fabrics were firstly epoxidized using epichlorohydrin prior amination. Optimization of the reaction conditions, e.g., temperature, medium pH, amine type and metal type and their concentrations, are reported. Aminated fabrics of viscose and acrylic were shown to be viable for chelation with divalent metal cations. The overall results revealed that antibacterial resistance of metalized aminated fabrics that the activity trend of metals is in the order Cu-complex>Zn-complex>Ni-complex with regard to fighting of microorganisms and permanent even after 10 washing. Reaction mechanism of epoxidation, amination and metal chelation of fabrics are offered supported by FT-IR structural study, nitrogen content and atomic absorption spectroscopy. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Acrylic partial dentures--interim or permanent prostheses?

    Science.gov (United States)

    Wilson, V J

    2009-11-01

    An acrylic partial denture (APD) is one option for replacing missing teeth and is also the most cost effective treatment option. Dentists are faced with the demand for replacing missing teeth from patients with limited financial resources; therefore the replacement of missingteeth with an APD is a common occurrence. One of the disadvantages of APD's is its poor strength. Dentists and dental technicians tend to design and construct acrylic partial dentures with little or no tooth support. This can have a detrimental effect on the surrounding hard as well as soft tissue. This article argues that APD's can be considered as a permanent prosthesis, provided that proper patient selection, education and the principles of partial denture design are adhered to.

  20. Plant oil-based shape memory polymer using acrylic monolith

    Directory of Open Access Journals (Sweden)

    T. Tsujimoto

    2015-09-01

    Full Text Available This article deals with the synthesis of a plant oil-based material using acrylic monolith. An acrylic monolith bearing oxirane groups was prepared via simple technique that involved the dissolution of poly(glycidyl methacrylate-comethyl methacrylate (PGMA in ethanolic – aqueous solution by heating and subsequent cooling. The PGMA monolith had topologically porous structure, which was attributed to the phase separation of the polymer solution. The PGMA monolith was impregnated by epoxidized soybean oil (ESO containing thermally-latent catalyst, and the subsequent curing produced a crosslinked material with relatively good transparency. The Young’s modulus and the tensile strength of polyESO/PGMA increased compared with the ESO homopolymer. The strain at break of polyESO/PGMA was larger than that of the ESO homopolymer and crosslinked PGMA. Furthermore, polyESO/PGMA exhibited good shape memory-recovery behavior.

  1. Relative Clinical Success of Bis-Acryl Composite Provisional Crowns.

    Science.gov (United States)

    Kozmacs, Carla; Baumann, Vanessa; Bunz, Oskar; Piwowarczyk, Andree

    2018-01-01

    The high demands on the clinical performance of a single-tooth provisional restoration necessitate that said performance be examined. The authors evaluated 24 teeth evaluated. Two test groups received bis-acrylic composite for provisional crowns (n = 12) and a single-unit, self-supporting, malleable, light-curing composite crown (n = 12). Final crowns (n = 24) served as paired controls. Evaluation of clinical success was measured using previously selected subcategories of FDI criteria. Statistical analysis was performed using McNemar's Test (α = 0.05). The null hypothesis of no improvement of the definitive crown relative to the provisionals was rejected at the 5% significance level (McNemar's P value provisional crowns, 75% received a clinically insufficient valuation, while only 8% of the definitive crowns did. The authors concluded that, independent of the manufacturing process, a bis-acrylic composite provisional crown cannot serve as a replacement for a conventionally manufactured definitive crown.

  2. INCIDENCE AND CAUSES OF FRACTURE OF ACRYLIC RESIN COMPLETE DENTURE

    OpenAIRE

    Sampa; Pradip Kumar; Manabendra; Saibal Kumar

    2014-01-01

    CONTEXT (BACKGROUND): Replacement of missing teeth and the associated structures are done with the help of artificial prosthesis. Acrylic resin, by virtue of its excellent properties is widely used as a material of choice for fabrication of denture base. In spite of its higher esthetic quality, tissue compatibility and ease of manipulation, it has an inherent deficiency of proneness to fracture. AIMS: The present study was being undertaken to find out the incidence of frac...

  3. Effectiveness of coating acrylic resin dentures on preventing Candida adhesion.

    Science.gov (United States)

    Ali, Aiman A; Alharbi, Fahad A; Suresh, C S

    2013-08-01

    The aim of this study was to prevent the adhesion of C. albicans on acrylic resin dentures by modifying their surfaces. Ninety acrylic resin plates were divided into three groups. Group I: conventionally processed acrylic resin plates. Group II: plates painted with 2-Octyl Cyanoacrylate adhesive. Group III: plates painted with Adper Single Bond Adhesive. All specimens were immersed separately in containers filled with artificial saliva that contained C. albicans and then incubated for 11 days at 37°C. Three methods of evaluation were used to count the adhered Candida: direct culture, slide count, and serial dilutions. C. albicans in 1/10, 1/10², and 1/10³ dilutions showed overgrowth in group I, while overgrowth was noted only with 1/10 dilution in group III. For group III, mean colony numbers of 123, 22, 3.4, and 0 were found for the 1/10², 1/10³, 1/10⁴, and 1/10⁵ dilutions, respectively. Regarding the slide counts, group I showed a mean fungal count of 166 compared to 40 for group III with 1/10 dilution, 21 compared to 9 with 1/10³ dilution, 8.6 compared to 0.7 with 1/10³ dilution, and 1.2 compared to 0 with 1/10⁴ dilution. No plates in group II showed any candidal colonies regardless of the method of evaluation (0%). These differences were statistically significant (p acrylic resin dentures with Adper Single Bond Adhesive was effective in reducing C. albicans adhesion to dentures, while coating with 2-Octyl Cyanoacrylate adhesive completely inhibited such adhesion. © 2013 by the American College of Prosthodontists.

  4. FDG gamma camera PET equipped with one inch crystal and XCT. Assessment of myocardial viability

    Energy Technology Data Exchange (ETDEWEB)

    Beheshti, M. [Dept. of Nuclear Medicine, Medical Univ., General Hospital of Vienna (Austria); Dept. of Nuclear Medicine and Endocrinology, PET CT Centre, St. Vincent' s Hospital, Linz (Austria); Khorsand, A.; Graf, S. [Dept. of Cardiology, Medical Univ., General Hospital of Vienna (Austria); Dobrozemsky, G. [Dept. of Nuclear Medicine, Medical Univ. of Innsbruck (Austria); Oezer, S.; Kletter, K.; Dudczak, R. [Dept. of Nuclear Medicine, Medical Univ., General Hospital of Vienna (Austria); Pirich, C. [Dept. of Nuclear Medicine und Endocrinology, Paracelsus Private Medical Univ., SALK, Salzburg (Austria)

    2006-07-01

    Metabolic imaging with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) is actually considered as the best method to detect and quantitatively assess myocordial tissue viability. The aim of this study was to investigate the accuracy of FDG gamma camera positron emission tomography (GCPET) imaging equipped with one inch NaI crystals in comparison to FDG dedicated PET (dPET) imaging as a ''gold standard'' in phantom and clinical studies. Patients, methods: nineteen patients with coronary artery disease (CAD) underwent both imaging modalities. Phantom and clinical GCPET imaging were performed with a dual-headed, coincidence based gamma camera equipped with 1 inch thick NaI crystals and an X-ray tube (XCT) for attenuation correction (AC), as well as with a dedicated PET scanner with AC. {sup 99m}Tc tetrofosmin single-photon emission tomography (SPET) studies were performed for assessment of myocardial perfusion, with AC. Results: phantom studies showed a significant relation in segmental activity between FDG imaging with AC using GCPET and dPET (r = 0.91, p < 0.001). In clinical studies with AC correlation coefficients of mean segmental FDG uptake and regional defect size were r = 0.87 (p < 0.0001) and r = 0.83 (p < 0.0001), respectively. In regional analysis close agreement was even found in the most attenuated regions of the heart if AC was used in GCPET imaging. The overall agreement for detection of viable myocardium was 81% between FDG-dPET (AC) and FDG-GCPET (AC) and 74% between FDG-dPET (AC) and FDG-GCPET (NC). Conclusions: suggests that the assessment of myocardial metabolism by means of FDG is feasible with a coincidence based gamma camera equipped with 1 inch thick NaI crystal if AC is performed. The results reveal a close concordance and agreement between FDG-dPET (AC) and FDG-GCPET (AC) as compared to FDG-GCPET (NC). (orig.)

  5. Slow- Release Fertilizer Formulation Using Acrylic and Chitosan Coating

    Directory of Open Access Journals (Sweden)

    Lili Handayani

    2015-01-01

    Full Text Available The low-efficiency problem in fertilizer application can be overcome by controlling fertilizer solubility, i.e. by rendering the fertilizer to be released gradually; such material is also known as slow-release fertilizer (SRF. This research was aimed to formulate SRF by coating technique using acrylic and chitosan as the coating material, and to evaluate fertilizer resistance to too fast disintegration, and rate of nutrient release method. The results demonstrated that fertilizer formulation containing N, P, K, Fe, Cu, and Zn with granulation technique yielded 74% of granules with 2-5 mm in diameter. The SRFs (formulated fertilizer with acrylic or chitosan coating were more resistant to water pounding than non-SRF. Furthermore, shaking test with distilled water or 2% citric acid, or by percolation test with distilled water showed that the SRFs had lower nutrient solubility than the non-SRFs. The results of shaking test also specifically indicated that coating with acrylic made the fertilizer more resistant to the citric acid,suggesting that this coating material would be more suitable in acidic soils. The SRFs formulated with the addition of chitosan during blending of micronutrients prior to mixing with macronutrients, granulation, and final coating exhibited lower nutrient solubility than the SRFs without the pre-coating chitosan addition.

  6. Amphiphilic photosensitive dextran-g-poly(o-nitrobenzyl acrylate) glycopolymers.

    Science.gov (United States)

    Soliman, Soliman Mehawed Abdellatif; Colombeau, Ludovic; Nouvel, Cécile; Babin, Jérôme; Six, Jean-Luc

    2016-01-20

    Among all photosensitive monomers reported in the literature, o-nitrobenzyl acrylate (NBA) was selected in this present study. Two strategies were compared to produce azido-terminated poly(o-nitrobenzyl acrylate) (PNBA) using controlled Single Electron Transfer-Living Radical Polymerization (SET-LRP). In a parallel way, dextran (Dex) was modified by the introduction of several alkynyl-terminated hydrophobic chains. Finally, an Huisgen-type Copper (I)-catalyzed Azide-Alkyne Cycloaddition (CuAAC) click-chemistry was carried out to produce amphiphilic Dex-g-PNBA glycopolymers with different number and length of PNBA grafts. 2D DOSY (1)H NMR was used to prove the formation of such glycopolymers. Preliminary study on Dex-g-PNBA self-assembly was done by measuring the critical water content (CWC) above which Dex-g-PNBA started to auto-organize themselves to produce nano-objects. Finally, under UV irradiation, PNBA grafts turn into poly(acrylic acid) ones giving light-sensitive properties to such amphiphilic Dex-g-PNBA. Such properties were evaluated and compared with those of PNBA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Thermogravimetric analysis of photodegraded acrylic coated lime wood.

    Science.gov (United States)

    Popescu, Carmen-Mihaela; Tibirna, Carmen Mihaela; Vasile, Cornelia

    2011-01-01

    A series of experiments were carried out to investigate the photodegradation of lime wood (Tilia cordata Mill.) coated with acrylic copolymer during artificial UV/Vis light irradiation for 600 h. Photodegradation of the Paraloid B72 films and Paraloid B72 treated lime wood samples was evaluated by thermogravimetry throughout the irradiation period of 100 h. The results obtained indicate a shifting of the DTG maxima to lower temperatures, which may be related to a decrease in the stability of the copolymer and wood during photodegradation. The decrease of weight loss with increasing time of exposure was observed, while the global kinetic parameters for the main peak increases when increasing exposure time of wood to the UV light. Even when the surface of the wood was covered with a thin layer of acrylic resin, some photodegradation reactions of the wood surface occurred. The modifications in the wood structure may be influenced by the newly formed structures from acrylic resin photodegradation. © 2011 The Authors. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  8. Midline Fractures in Single Maxillary Complete Acrylic vs Flexible Dentures.

    Science.gov (United States)

    Dhiman, R K; Chowdhury, Sk Roy

    2009-04-01

    Patients using single maxillary denture against their natural mandibular teeth face the problem of midline fracture in their routine acrylic dentures. Various techniques have failed over the years to address the problem. In this study, flexible denture material (Lucitone) with injection moulding system has been used and evaluated for midline fracture in these patients. A total of 58 patients in the age group of 38 to 80 years, who had experienced midline fracture in their acrylic maxillary dentures were selected. They were provided with new dentures using flexible denture material. Various parameters, namely, mastication, phonetics, esthetics and comfort level were evaluated. Only two cases reported slight crack in the palatal region of the-maxillary dentures after 18 months of use. Mastication and phonetics were found to be improved with flexible dentures. The flexible denture is a promising material for preventing midline fractures in a single maxillary denture. It is well tolerated by the patients as compared to the methyl meth-acrylate dentures.

  9. Comparison of patient satisfaction with acrylic and flexible partial dentures.

    Science.gov (United States)

    Akinyamoju, Clara Arianta; Ogunrinde, Tunde Joshua; Taiwo, Juliana Obontu; Dosumu, Oluwole Oyekunle

    2017-01-01

    Restoration of partial edentulous mouth may be done using a variety of treatment options. Removable partial denture (RPD) is commonly used because of its availability. RPDs from flexible resins unlike those from acrylic engage hard and soft tissue undercuts and feel more comfortable in the mouth. The aim of the study was to compare satisfaction with dentures made from these two types of materials. It was a quasi-experimental study among thirty patients at the Prosthetics Clinic, University College Hospital, Ibadan. Patients aged 16 years or more, requiring RPDs with one to three missing teeth in the anterior region of either the upper or lower arch participated. A modified semi-structured interviewer-administered questionnaire was used to collect data on sociodemographics and oral health variables. The level of satisfaction was assessed using a visual analogue scale. Data were analysed using descriptive and multivariate statistics at a significance level of P dentures, 6 (20.0%) with acrylic dentures while 3 (10.0%) were equally satisfied with both types of dentures (P = 0.04). Subjects were more satisfied with the flexible RPD than the acrylic resin RPD.

  10. Microhardness of heat cure acrylic resin after treatment with disinfectants.

    Science.gov (United States)

    Amin, Faiza; Rehman, Abdur; Abbas, Muhammad

    2015-08-01

    To evaluate the effect of disinfectants and distilled water on the micro-hardness of heat cure acrylic resins. The case-control study was conducted at Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, and Nadirshaw Edulji Dinshaw University of Engineering and Technology, Karachi, from April to October 2011. Specimens were fabricated from heat cure acrylic resin material and they were divided into four equal groups. Group 1 was evaluated at baseline and was taken as the control group. Group 2 was immersed in distilled water for 20 minutes, Group 3 in1% sodium hypochlorite for 20 minutes, and Group 4 in 2% alkaline gluteraldehyde for 10 minutes. All specimens were polished, stored in distilled water for 24 hours prior to experiment. All the specimens were immersed twice daily for a total of 60 days after which they were tested for Vickers micro-hardness test. Statistical analysis was conducted with one-way analysis of variance and Tukey post hoc test (a=0.05). There were 72 specimens divided into four groups of 18(25%) each. Statistically significant differences were found among all groups (pacrylic resins. Group 4 showed the most reduction in the hardness value which was followed by Group 3. The hardness of heat cure acrylic resin was affected by disinfectants.

  11. Antifungal Effect of Silver Nanoparticles in Acrylic Resins

    Directory of Open Access Journals (Sweden)

    Ahmad Ghahremanloo

    Full Text Available Introduction: In patients using dental prosthesis, growth of various microorganisms under the prosthesis base which leads to inflammation and infections such as candidiasis is common. The aim of this study was to assess the antifungal effects of acrylic resins containing silver nanoparticles on candida Albicans.Materials & Methods: To accomplish this in vitro study inorder to prepare acrylic samples, metallic cylindricals with a diameter of 10mm and thickness of 4mm were used. Forty samples as standard control group and 40 samples containing silver nanoparticles in four different concentrations were used. Immersion of samples in fungal suspension (standard and hospitally isolated were carried out to accomplish antifungal tests. After 0,1,6 and 24 hours the fungal colonies were counted. To describe the data and to compare groups, student-t test was used.Results: In the silver nanoparticles with 2.5% concentration, the highest mean difference for standard candida Albicans after 24 hours of exposure time was 501.0±23.1 and for 5% concentration after 6 hours of exposure time was 953±87 and for 10% concentration after 6 hours of exposure time was 1000±24.9.Conclusion: In acrylic resins, increasing both the silver nanoparticles concentration and the exposure time will increase the antifungal effect.

  12. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  13. Testing of one-inch UF{sub 6} cylinder valves under simulated fire conditions

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, P.G. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Accurate computational models which predict the behavior of UF{sub 6} cylinders exposed to fires are required to validate existing firefighting and emergency response procedures. Since the cylinder valve is a factor in the containment provided by the UF{sub 6} cylinder, its behavior under fire conditions has been a necessary assumption in the development of such models. Consequently, test data is needed to substantiate these assumptions. Several studies cited in this document provide data related to the behavior of a 1-inch UF{sub 6} cylinder valve in fire situations. To acquire additional data, a series of tests were conducted at the Paducah Gaseous Diffusion Plant (PGDP) under a unique set of test conditions. This document describes this testing and the resulting data.

  14. Recent developments in high charge state heavy ion beams at the LBL 88-inch Cyclotron

    International Nuclear Information System (INIS)

    Gough, R.A.; Clark, D.J.; Glasgow, L.R.

    1978-01-01

    Recent advances in design and operation of the internal PIG sources at the LBL 88-Inch Cyclotron have led to the development of high charge state (0.4 16 O 8+ . Total external intensities of these beams range from 10 12 particles/s for 6 Li 3+ to 0.1 particles/s for 16 O 8+ . Techniques have been developed for routine tune-out of the low intensity beams. These include use of model beams and reliance on the large systematic data base of cyclotron parameters which has been developed over many years of operation. Techniques for delivery of these weak beams to the experimental target areas are presented. Source design and operation, including special problems associated with Li, Be, and B beams are discussed

  15. LOFT transient thermal analysis for 10 inch primary coolant blowdown piping weld

    International Nuclear Information System (INIS)

    Howell, S.K.

    1978-01-01

    A flaw in a weld in the 10 inch primary coolant blowdown piping was discovered by LOFT personnel. As a result of this, a thermal analysis and fracture mechanics analysis was requested by LOFT personnel. The weld and pipe section were analyzed for a complete thermal cycle, heatup and Loss of Coolant Experiment (LOCE), using COUPLE/MOD2, a two-dimensional finite element heat conduction code. The finite element representation used in this analysis was generated by the Applied Mechanics Branch. The record of nodal temperatures for the entire transient was written on tape VSN=T9N054, and has been forwarded to the Applied Mechanics Branch for use in their mechanical analysis. Specific details and assumptions used in this analysis are found in appropriate sections of this report

  16. Development and characterization of a CCD camera system for use on six-inch manipulator systems

    International Nuclear Information System (INIS)

    Logory, L.M.; Bell, P.M.; Conder, A.D.; Lee, F.D.

    1996-01-01

    The Lawrence Livermore National Laboratory has designed, constructed, and fielded a compact CCD camera system for use on the Six Inch Manipulator (SIM) at the Nova laser facility. The camera system has been designed to directly replace the 35 mm film packages on all active SIM-based diagnostics. The unit's electronic package is constructed for small size and high thermal conductivity using proprietary printed circuit board technology, thus reducing the size of the overall camera and improving its performance when operated within the vacuum environment of the Nova laser target chamber. The camera has been calibrated and found to yield a linear response, with superior dynamic range and signal-to-noise levels as compared to T-Max 3200 optic film, while providing real-time access to the data. Limiting factors related to fielding such devices on Nova will be discussed, in addition to planned improvements of the current design

  17. The evolution of palm oil acrylates within 20 years in Nuclear Malaysia

    International Nuclear Information System (INIS)

    Mek Zah Salleh; Rida Tajau; Nurul Huda Mudri

    2016-01-01

    Acrylated palm oil was synthesized from epoxidized palm oil (EPOP), in early 1989, through acrylation/methacrylation process at Radiation Technology Division laboratory. The acrylated products namely Epoxidized Palm Oil Acrylate/Methacrylate (EPOLA/ EPOMA), with the molecular weight around 2000-3000 g/mol, was found curable when subjected to UV or EB irradiations. Isocyanation of EPOLAs resulted in a resin called Palm Oil Based Urethane Acrylate (POBUA). POBUA possess certain advantages over EPOLA such as much higher molecular weight between 5000 to 20000 g/ mol, better curing speed, crosslinking density, higher abrasion resistance and also higher pendulum hardness. Hyper branched polyurethane acrylate (HBPUA) from palm oil oleic was synthesized by a three-step reaction in 2012. The reaction was confirmed by several analytical data; hydroxyl value (OHV), FTIR, GPC and NMR spectroscopy analyses. The thermal decomposition of HBPUA formulations shows good thermal stability up to 450 degree Celsius. (author)

  18. Waterborne hyperbranched alkyd-acrylic resin obtained by mini emulsion polymerization

    International Nuclear Information System (INIS)

    Murillo, Edwin; Lopez, Betty

    2016-01-01

    Four waterborne hyper branched alkyd-acrylic resins (HBRAA) were synthesized by mini emulsion polymerization from a hyper branched alkyd resin (HBR), methyl methacrylate (MMA), butyl acrylate (BA) and acrylic acid (AA), by using benzoyl peroxide (BPO) and ammonium persulfate (AP) as initiators. The reaction between HBR and acrylic monomers was evidenced by differential scanning calorimetric (DSC), nuclear magnetic resonance (NMR) and gel permeation chromatography (GPC). The conversion percentage, glass transition temperature (T g ), content of acrylic polymer (determined by soxhlet extraction) and molecular weight increased with the content of acrylic monomers used in the synthesis. The main structure formed during the synthesis was the HBRAA. The analysis by dynamic light scattering (DLS) showed that the particle size distribution of HBRAA2, HBRAA3 and HBRAA4 resins were mainly mono modal. The film properties (gloss, flexibility, adhesion and drying time) of the HBRAA were good. (author)

  19. Effects of laboratory disinfecting agents on color stability of denture acrylic resins.

    Science.gov (United States)

    McNeme, S J; von Gonten, A S; Woolsey, G D

    1991-07-01

    This study determined the effects of chemical disinfecting agents on denture acrylic resins. Tested resins included the products CH Lucitone, Triad VLC, and Truliner. The disinfecting agents were sodium hypochlorite, Exspor, Cidex, and Wescodyne-D. Acrylic resin samples were placed in the various disinfecting agents and then evaluated for color changes at time intervals ranging from 15 minutes to 72 hours. No observable color change of any acrylic resin was seen before 2 hours. Both 1% sodium hypochlorite and 2% Cidex disinfectants produced the least discoloration of the acrylic resins, and Wescodyne-D disinfectant produced the most acrylic resin discoloration. Truliner resin discolored more than Triad VLC resin, and both underwent more color change than CH Lucitone resin. If manufacturers' recommended disinfecting times are followed, clinical and laboratory disinfection of acrylic resin dentures should cause no observable color change.

  20. Waterborne hyperbranched alkyd-acrylic resin obtained by mini emulsion polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Murillo, Edwin, E-mail: edwinalbertomurillo@gmail.com [Grupo de Investigacion en Materiales Polimericos (GIMAPOL), Universidad Francisco de Paula Santander, San Jose de Cucuta (Colombia); Lopez, Betty [Grupo de Investigacion en Ciencia de los Materiales, Universidad de Antioquia, Calle, Medellin (Colombia)

    2016-10-15

    Four waterborne hyper branched alkyd-acrylic resins (HBRAA) were synthesized by mini emulsion polymerization from a hyper branched alkyd resin (HBR), methyl methacrylate (MMA), butyl acrylate (BA) and acrylic acid (AA), by using benzoyl peroxide (BPO) and ammonium persulfate (AP) as initiators. The reaction between HBR and acrylic monomers was evidenced by differential scanning calorimetric (DSC), nuclear magnetic resonance (NMR) and gel permeation chromatography (GPC). The conversion percentage, glass transition temperature (T{sub g}), content of acrylic polymer (determined by soxhlet extraction) and molecular weight increased with the content of acrylic monomers used in the synthesis. The main structure formed during the synthesis was the HBRAA. The analysis by dynamic light scattering (DLS) showed that the particle size distribution of HBRAA2, HBRAA3 and HBRAA4 resins were mainly mono modal. The film properties (gloss, flexibility, adhesion and drying time) of the HBRAA were good. (author)

  1. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    Science.gov (United States)

    Tajau, Rida; Ibrahim, Mohammad Izzat; Yunus, Nurulhuda Mohd; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik

    2014-02-01

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough.

  2. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    International Nuclear Information System (INIS)

    Rida Tajau; Nurulhuda Mohd Yunus; Mohd Hilmi Mahmood; Mek Zah Salleh; Nik Ghazali Nik Salleh

    2013-01-01

    Full-text: The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidized palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) for example EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80 %) than the palm oil based compounds (up to 70 %), where the different is around 10-15 %. The hardness property from this two type coatings can reached until 50 % at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newton's (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photo initiator give higher adhesion property and their also showed a higher glossiness property on the glass substrate compared to the coatings containing irgacure-819 photo initiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough. (author)

  3. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    International Nuclear Information System (INIS)

    Tajau, Rida; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik; Ibrahim, Mohammad Izzat; Yunus, Nurulhuda Mohd

    2014-01-01

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough

  4. Development of palm oil-based UV-curable epoxy acrylate and urethane acrylate resins for wood coating application

    Energy Technology Data Exchange (ETDEWEB)

    Tajau, Rida; Mahmood, Mohd Hilmi; Salleh, Mek Zah; Salleh, Nik Ghazali Nik [Radiation Processing Technology Division, Malaysian Nuclear Agency (Nuclear Malaysia), Bangi, 43000 Kajang, Selangor (Malaysia); Ibrahim, Mohammad Izzat [Faculty of Science, University of Malaya (UM), 50603 Kuala Lumpur (Malaysia); Yunus, Nurulhuda Mohd [Faculty of Science and Technology, National University Malaysia (UKM), 43600 Bangi, Selangor (Malaysia)

    2014-02-12

    The trend of using renewable sources such as palm oil as raw material in radiation curing is growing due to the demand from the market to produce a more environmental friendly product. In this study, the radiation curable process was done using epoxy acrylate and urethane acrylate resins which are known as epoxidised palm olein acrylate (EPOLA) and palm oil based urethane acrylate (POBUA), respectively. The purpose of the study was to investigate curing properties and the application of this UV-curable palm oil resins for wood coating. Furthermore, the properties of palm oil based coatings are compared with the petrochemical-based compound such as ebecryl (EB) i.e. EB264 and EB830. From the experiment done, the resins from petrochemical-based compounds resulted higher degree of crosslinking (up to 80%) than the palm oil based compounds (up to 70%), where the different is around 10-15%. The hardness property from this two type coatings can reached until 50% at the lower percentage of the oligomer. However, the coatings from petrochemical-based have a high scratch resistance as it can withstand at least up to 3.0 Newtons (N) compared to the palm oil-based compounds which are difficult to withstand the load up to 1.0 N. Finally, the test on the rubber wood substrate showed that the coatings containing benzophenone photoinitiator give higher adhesion property and their also showed a higher glosiness property on the glass substrate compared to the coatings containing irgacure-819 photoinitiator. This study showed that the palm oil coatings can be a suitable for the replacement of petrochemicals compound for wood coating. The palm oil coatings can be more competitive in the market if the problems of using high percentage palm oil oligomer can be overcome as the palm oil price is cheap enough.

  5. The transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion

    OpenAIRE

    Rianti, Devi

    2006-01-01

    A laboratoric experimental study was conducted on the transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion. The aim of this study is to know the difference of acrylic resin transverse strengths caused by immersion time variations in a concentrate solution. The study was carried out on unpolished acrylic resin plates with 65 × 10 × 2,5 mm dimension; solution with 15% Coleus amboinicus, Lour extract, and 30, 60, 90 days immersion times to measure the tra...

  6. Effect of silver nanoparticles incorporation on viscoelastic properties of acrylic resin denture base material

    OpenAIRE

    Mahross, Hamada Zaki; Baroudi, Kusai

    2015-01-01

    Objective: The objective was to investigate the effect of silver nanoparticles (AgNPs) incorporation on viscoelastic properties of acrylic resin denture base material. Materials and Methods: A total of 20 specimens (60 ? 10 ? 2 mm) of heat cured acrylic resin were constructed and divided into four groups (five for each), according to the concentration of AgNPs (1%, 2%, and 5% vol.) which incorporated into the liquid of acrylic resin material and one group without additives (control group). Th...

  7. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

    OpenAIRE

    Jang, Dae-Eun; Lee, Ji-Young; Jang, Hyun-Seon; Lee, Jang-Jae; Son, Mee-Kyoung

    2015-01-01

    PURPOSE The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study...

  8. Investigation of neighbour group effects in releasing of 5-aminosicylic acid from acrylic polymeric prodrugs

    OpenAIRE

    Babzadeh, Mirzaagha; Naserian, Sona

    2011-01-01

    Acrylic-type polymeric systems having degradable ester bonds linked to 5-ASA were synthesized and evaluated az materials for drug delivery. prodrugs. 5-aminosalicylic acid (5-ASA) was linked to 2-hydroxypropyl methacrylate by carbonyldiimidazole (CDI) to obtain metachryloyloxy propyl 5-amino salicylate. The resulting acrylic derivative of 5-ASA was copolymerized with 2-hydroxyethyl methacrylat, methyl metacrylat and 2-ethylh hexyl acrylate (in 1:3 mole ratio) by free radical polymerization me...

  9. Influence of Zwitterions on Thermomechanical Properties and Morphology of Acrylic Copolymers: Implications for Electroactive Applications

    Science.gov (United States)

    2011-09-30

    properties of ethyl acrylate and n-butyl acrylate ( nBA )-based sulfobetaine-containing copolymers.10,11 They found that the incorporation of...ammonio]-1-propanesulfonate (SBMA), a zwitterionic mono- mer. Copolymerization of both charge-containing monomers with nBA elucidates the influence of...3-[[2-(methacryloyloxy)ethyl]- (dimethyl)ammonio]-1-propanesulfonate (SBMA), was generously provided by Raschig GmbH. n-Butyl acrylate ( nBA , Alfa

  10. The potential dermal irritating effect of residual (meth)acrylic monomers in pressure sensitive adhesive tapes.

    Science.gov (United States)

    Tokumura, Fumio; Matsui, Tetsuya; Suzuki, Yasuko; Sado, Masashi; Taniguchi, Masaharu; Kobayashi, Ichiro; Kamiyama, Masashi; Suda, Shin; Nakamura, Atsushi; Yamazaki, Yuhiro; Yamori, Akira; Igarashi, Ryosuke; Kawai, Jun; Oka, Keiji

    2010-01-01

    It is generally thought that residual unpolymerized (meth)acrylic monomers commonly found in pressure sensitive adhesive tapes for medical use may cause dermal irritation, but a systematic study has never been carried out. Therefore, we assessed the potential dermal irritating effect of residual (meth)acrylic monomers. We studied seven acrylic monomers, acrylic acid (AA), methyl acrylate (MA), ethyl acrylate (EA), n-butyl acrylate (n-BA), n-hexyl acrylate (n-HA), 2-ethylhexyl acrylate (2-EHA) and 2-hydroxyethyl acrylate (HEA), as well as three methacrylic monomers, methacrylic acid (MAA), methyl methacrylate (MMA) and 2-hydroxyethyl methacrylate (2-HEMA). We first examined their cytotoxic effect on a cultured dermis model using the MTT method to determine their EC(50) and then performed a primary irritation test in rabbits using the monomers at three different concentrations (i.e., EC(50) , one-tenth EC(50) and 10 times EC(50)). Marked variations were found in cytotoxic and dermal irritating activities among the (meth)acrylic monomers tested. HEA exhibited the most potent dermal irritation having the lowest erythema dose (the concentration which gives a primary dermal irritation index of 1.00) of 460 ppm. But the other monomers exhibited less potent dermal irritation (lowest erythema doses > or =1000 ppm). For the monomers, significant correlation was found between cytotoxic activity and in vivo dermal irritating activity. Our results show that residual unpolymerized (meth)acrylic monomers in adhesive tapes are unlikely to induce skin irritation except for HEA. This study also suggests that cultured skin models are extremely useful as a screening method for chemical substances that could potentially cause dermal irritating activity.

  11. Temperature programmable microfabricated gas chromatography column

    Science.gov (United States)

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  12. 29 CFR 1926.755 - Column anchorage.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Column anchorage. 1926.755 Section 1926.755 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.755 Column anchorage. (a) General requirements for erection stability. (1) All columns shall be anchored by a minimum of 4 anchor...

  13. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials.

    Science.gov (United States)

    Heidari, Bijan; Firouz, Farnaz; Izadi, Alireza; Ahmadvand, Shahbaz; Radan, Pegah

    2015-05-01

    Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a common clinical occurrence, which often develops in the midline of the denture base. This study aimed to evaluate the efficacy of cold-cure and heat-cure acrylic resins, reinforced with glass fibers, polyethylene fibers, and metal wire for denture base repair. Ninety specimens were prepared and allocated to nine groups. Ten specimens were considered as controls, and 80 were divided into 8 experimental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was divided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were subjected to a 3-point bending test, and the flexural strength was calculated. The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement. Repairing denture base with heat cure acrylic resin, reinforced with glass fibers increases the flexural strength of denture base.

  14. Thermal Modeling Analysis Of CST Media In The Small Column Ion Exchange Project

    International Nuclear Information System (INIS)

    Lee, S.

    2010-01-01

    immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed (a primary heat transfer mechanism), inadvertent column drainage, and loss of active cooling in the column. The calculation results showed that for a wet CST column with active cooling through one central and four outer tubes and 35 C ambient external air, the peak temperature for the fully-loaded column is about 63 C under the loss of fluid flow accident, which is well below the supernate boiling point. The peak temperature for the naturally-cooled (no active, engineered cooling) wet column is 156 C under fully-loaded conditions, exceeding the 130 C boiling point. Under these conditions, supernate boiling would maintain the column temperature near 130 C until all supernate was vaporized. Without active engineered cooling and assuming a dry column suspended in unventilated air at 35 C, the fully-loaded column is expected to rise to a maximum of about 258 C due to the combined loss-of coolant and column drainage accidents. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. Results for the in-tank modeling calculations clearly indicate that when realistic heat transfer boundary conditions are imposed on the bottom surface of the tank wall, as much as 450 gallons of ground CST (a volume equivalent to two ion exchange processing cycles) in an ideal hemispherical shape (the most conservative geometry) can be placed in the tank without exceeding the 100 C wall temperature limit. Furthermore, in the case of an evenly-distributed flat layer, the tank wall reaches the temperature limit after the ground CST material reaches a height of approximately 8 inches.

  15. Experimental Study and Numerical Solution of Poly Acrylic Acid Supported Magnetite Nanoparticles Transport in a One-Dimensional Porous Media

    Directory of Open Access Journals (Sweden)

    M. Golzar

    2014-01-01

    Full Text Available Recently, iron nanoparticles have attracted more attention for groundwater remediation due to its potential to reduce subsurface contaminants such as PCBs, chlorinated solvents, and heavy metals. The magnetic properties of iron nanoparticles cause to attach to each other and form bigger colloid particles of iron nanoparticles with more rapid sedimentation rate in aqueous environment. Using the surfactants such as poly acrylic acid (PAA prevents iron nanoparticles from forming large flocs that may cause sedimentation and so increases transport distance of the nanoparticles. In this study, the transport of iron oxide nanoparticles (Fe3O4 stabilized with PAA in a one-dimensional porous media (column was investigated. The slurries with concentrations of 20,100 and 500 (mg/L were injected into the bottom of the column under hydraulic gradients of 0.125, 0.375, and 0.625. The results obtained from experiments were compared with the results obtained from numerical solution of advection-dispersion equation based on the classical colloid filtration theory (CFT. The experimental and simulated breakthrough curves showed that CFT is able to predict the transport and fate of iron oxide nanoparticles stabilized with PAA (up to concentration 500 ppm in a porous media.

  16. Effect of 5.25 % sodium hypochlorite on color stability of acrylic and silicone based soft liners and a denture base acrylic resin.

    Science.gov (United States)

    Salloum, Alaa'a M

    2014-06-01

    The purpose of the current study was to investigate the effect of a chemical disinfectant (sodium hypochlorite 5.25 %) on color stability of a denture base acrylic resin and two processed soft denture lining materials of two different types (acrylic-based and silicone-based). Ten specimens from each type of materials tested were made (2 × 20 × 20 mm). All specimens were immersed in sodium hypochlorite (5.25 %). Colorimetric measurements for each specimen were taken before immersion, and after 24 h and 7 days of immersion. Color changes were evaluated using the CIE L*a*b* colorimetric system. Data were statistically analyzed with one-way analysis of variance (ANOVA) (α = 0.05). ANOVA was followed by Bonferroni test to determine which groups differed from each other. ΔE and ΔL* of the silicone-based liner at the 1st and 7th days of immersion were significantly more than of denture base acrylic resin and acrylic-based liner. Change in ΔL* values of denture base acrylic resin and acrylic-based liner was small and statistically insignificant after 24 h of its immersion. However, the increase in ΔL* values of the acrylic-based liner after 7 days of immersion was considerably more than of denture base acrylic resin. Color changes in denture base acrylic resin and soft denture liners tended to increase with longer immersion times, and the color stability of the soft denture liners was influenced by its chemical type.

  17. Axisymmetric collapses of granular columns

    Science.gov (United States)

    Lube, Gert; Huppert, Herbert E.; Sparks, R. Stephen J.; Hallworth, Mark A.

    2004-06-01

    Experimental observations of the collapse of initially vertical columns of small grains are presented. The experiments were performed mainly with dry grains of salt or sand, with some additional experiments using couscous, sugar or rice. Some of the experimental flows were analysed using high-speed video. There are three different flow regimes, dependent on the value of the aspect ratio a {=} h_i/r_i, where h_i and r_i are the initial height and radius of the granular column respectively. The differing forms of flow behaviour are described for each regime. In all cases a central, conically sided region of angle approximately 59(°) , corresponding to an aspect ratio of 1.7, remains undisturbed throughout the motion. The main experimental results for the final extent of the deposit and the time for emplacement are systematically collapsed in a quantitative way independent of any friction coefficients. Along with the kinematic data for the rate of spread of the front of the collapsing column, this is interpreted as indicating that frictional effects between individual grains in the bulk of the moving flow only play a role in the last instant of the flow, as it comes to an abrupt halt. For a {reach r_infty is given by t_infty {=} 3(h_i/g)(1/2} {=} 3(r_i/g)({1/2}a^{1/2)) , where g is the gravitational acceleration. The insights and conclusions gained from these experiments can be applied to a wide range of industrial and natural flows of concentrated particles. For example, the observation of the rapid deposition of the grains can help explain details of the emplacement of pyroclastic flows resulting from the explosive eruption of volcanoes.

  18. Adhesive retention of experimental fiber-reinforced composite, orthodontic acrylic resin, and aliphatic urethane acrylate to silicone elastomer for maxillofacial prostheses.

    Science.gov (United States)

    Kosor, Begüm Yerci; Artunç, Celal; Şahan, Heval

    2015-07-01

    A key factor of an implant-retained facial prosthesis is the success of the bonding between the substructure and the silicone elastomer. Little has been reported on the bonding of fiber reinforced composite (FRC) to silicone elastomers. Experimental FRC could be a solution for facial prostheses supported by light-activated aliphatic urethane acrylate, orthodontic acrylic resin, or commercially available FRCs. The purpose of this study was to evaluate the bonding of the experimental FRC, orthodontic acrylic resin, and light-activated aliphatic urethane acrylate to a commercially available high-temperature vulcanizing silicone elastomer. Shear and 180-degree peel bond strengths of 3 different substructures (experimental FRC, orthodontic acrylic resin, light-activated aliphatic urethane acrylate) (n=15) to a high-temperature vulcanizing maxillofacial silicone elastomer (M511) with a primer (G611) were assessed after 200 hours of accelerated artificial light-aging. The specimens were tested in a universal testing machine at a cross-head speed of 10 mm/min. Data were collected and statistically analyzed by 1-way ANOVA, followed by the Bonferroni correction and the Dunnett post hoc test (α=.05). Modes of failure were visually determined and categorized as adhesive, cohesive, or mixed and were statistically analyzed with the chi-squared goodness-of-fit test (α=.05). As the mean shear bond strength values were evaluated statistically, no difference was found among the experimental FRC, aliphatic urethane acrylate, and orthodontic acrylic resin subgroups (P>.05). The mean peel bond strengths of experimental fiber reinforced composite and aliphatic urethane acrylate were not found to be statistically different (P>.05). The mean value of the orthodontic acrylic resin subgroup peel bond strength was found to be statistically lower (P.05). Shear forces predominantly exhibited cohesive failure (64.4%), whereas peel forces predominantly exhibited adhesive failure (93.3%). The

  19. Characterization of Bis-Acryl Composite Resins for Provisional Restorations.

    Science.gov (United States)

    Schwantz, Júlia K; Oliveira-Ogliari, Aline; Meereis, Carine T; Leal, Fernanda B; Ogliari, Fabrício A; Moraes, Rafael R

    2017-01-01

    This study investigated the in vitro performance of the commercial bis-acryl composite resins Systemp C&B II (SYS, Ivoclar Vivadent), Protemp 4 (PT4, 3M ESPE), Structur 2C (ST2, Voco) and ProviPlast (PVP, Biodinamica). Characterization involved optical (color stability, translucency parameter, fluorescence), surface (roughness, morphology and elemental composition), physical-chemical (viscosity, polymerization kinetics) and mechanical analyses (Poisson ratio, biaxial flexural strength, flexural modulus). Most tests were carried out after 24 h, but optical and mechanical analyses were carried out after storage in water at 37 °C for 1, 15, and 30 days. Data were statistically analyzed (a=0.05). Most results were material dependent. SYS and PT4 showed stability in color and translucency over time. All materials had similar or higher fluorescence than human enamel. SC2 and PVP showed rougher surfaces than the other bis-acryl composites. Smaller filler particles were observed on the surface of PT4 and PVP compared with the coarser particles from ST2 and SYS. Viscosity readings indicated a thixotropic behavior for all tested materials. SYS had the lowest and PT4 the highest degree of C=C conversion after 10 min. In the polymerization kinetics, PT4 had the highest maximum polymerization rate and reached earlier the transition between polymerization autoacceleration and autodeceleration. PT4 and SYS had significantly higher flexural strength and modulus than ST2 and PVP for most storage times. Results for Poisson ratio varied between materials. Longer storage periods were generally associated with higher frequency of catastrophic failures in the flexural tests. In conclusion, the performance of bis-acryl composite resins varied largely among materials.

  20. Photo stabilization of polymeric materials by photo set acrylate coatings

    Energy Technology Data Exchange (ETDEWEB)

    Decker, C. E-mail: c.decker@uha.fr; Zahouily, K

    2002-01-01

    Different types of polymeric materials have been made more resistant to photodegradation by protecting their surface with a UV-cured coating containing a HALS radical scavenger and a phenyl triazine UV absorber. The tri dimensional polymer network formed by photo polymerization of an aliphatic polyurethane-acrylate telechelic oligomer proved to be very resistant to accelerated weathering in the presence of these light stabilizers. The chemical modifications occurring upon QUV-ageing were monitored by infrared spectroscopy/ a very sensitive technique well suited for quantitative analysis at an early stage of the photodegradation.

  1. Radiation polymerisation of cyclohexyl acrylate in presence of cyclohexanol

    International Nuclear Information System (INIS)

    Roger, R.; Rao, M.H.; Rao, K.N.

    1986-01-01

    Radiation polymerisation of cyclohexyl acrylate in presence of cyclohexanol has been studied at various dose rates. The dose rate exponent determined approx. 0.66 indicates the possibility of the existence of the chain transfer to cyclohexanol. GPC chromatogram shows the presence of the low molecular weight polymer suppressing the high molecular weight fraction. These results suggest that the origin of the low molecular weight polymer could be through free radical initiation. High molecular weight fraction which is due to ionic initiation is suppressed completely indicating the possibility of cyclohexanol acting as a chain transfer agent for ions. (author)

  2. The radiolysis of styrene methyl acrylate copolymers: An ESR study

    International Nuclear Information System (INIS)

    Kellman, R.; Hill, D.T.J.; O'Donnell, J.H.; Pomery, P.J.

    1990-01-01

    The authors have examined the degradation of poly(styrene-co-methyl acrylate) under high-energy radiation, and wish to report results of an ESR study on the formation and fate of radical species produced during radiolysis. Radical yields, G[R], for STY-co-MA polymers have been determined at both 77K and 300K. ESR spectral analysis has allowed structural determination and an examination of the behavior of radicals species produced on radiolysis. Aspects of the free radical chemistry responsible for polymer degradation are discussed

  3. Electron beam curing polyurethane acrylate oligomer in air

    International Nuclear Information System (INIS)

    Zhu, Zhenkang; Chen, Xing; Zhou, Jichun; Ma, Zue-Teh

    1988-01-01

    It has been found according to our synthesis that a novel kind of polyurethane acrylate oligomer can be cured by electron beam in the presence of oxygen, even at normal atomospheric levels, without any additives. Irradiation of the oligomer with substantially complete cure to a solid non-tacky state is quite remarkable. It has the same gel content (90 %) in air as in nitrogen at dose of 33 kGy. Double bond conversion of the oligomer is about 50 % by I.R. (author)

  4. Alumina column Rb-82 generator

    International Nuclear Information System (INIS)

    Yano, Y.; Roth, E.P.

    1977-10-01

    The use of an alumina column for the adsorption of radioactive Sr for the generator production of 75-sec 82 Rb was evaluated in both batches and column experiments using 85 Sr and cyclotron-produced 82 Sr. Comparisons of alumina, Bio-Rex 70 and Chelex 100 ion exchangers were made to determine Sr adsorption, 82 Rb elution yield and Sr breakthrough. The adsorption of Sr is similar for alumina and Chelex 100 but different for Bio-Rex 70. Alumina and Chelex 100 exhibit a small fraction of poorly bound Sr which appears as higher breakthrough in the early elution volumes. The remaining Sr activity is strongly bound to these ion exchangers and the breakthrough remains stable at a lower breakthrough value through a large number of elutions. Bio-Rex 70 on the other hand does not exhibit the poorly bound Sr fraction and the breakthrough of Sr remains the lowest of the three ion exchangers through a moderate number of elutions and then the Sr breakthrough gradually increases with each additional elution

  5. The Berkeley accelerator space effects facility (BASE) - A newmission for the 88-inch cyclotron at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, M.A.

    2005-09-06

    In FY04, the 88-Inch Cyclotron began a new operating mode that supports a local research program in nuclear science, R&D in accelerator technology and a test facility for the National Security Space (NSS) community (the U.S. Air Force and NRO). The NSS community (and others on a cost recovery basis) can take advantage of both the light- and heavy-ion capabilities of the Cyclotron to simulate the space radiation environment. A significant portion of this work involves the testing of microcircuits for single event effects. The experimental areas within the building that are used for the radiation effects testing are now called the Berkeley Accelerator and Space Effects (BASE) facility. Improvements to the facility to provide increased reliability, quality assurance and new capabilities are underway and will be discussed. These include a 16 AMeV ''cocktail'' of beams for heavy ion testing, a neutron beam, more robust dosimetry, and other upgrades.

  6. Design evaluation of the 20-cm (8-inch) secondary burner system

    Energy Technology Data Exchange (ETDEWEB)

    Rode, J.S.

    1977-08-01

    This report describes an evaluation of the design of the existing 20-cm (8-inch) engineering-scale secondary burner system in the HTGR reprocessing cold pilot plant at General Atomic Co. The purpose of this evaluation is to assess the suitability of the existing design as a prototype of the HTGR Recycle Demonstration Facility (HRDF) secondary burner system and to recommend alternatives where the existing design is thought to be unsuitable as a prototype. This evaluation has led to recommendations for the parallel development of two integrated design concepts for a prototype secondary burner system. One concept utilizes the existing burner heating and cooling subsystems in order to minimize development risk, but simplifies a number of other features associated with remote maintenance and burner operation. The other concept, which offers maximum cost reduction, utilizes internal gas cooling of the burner, retains the existing heating subsystem for design compatibility, but requires considerable development to reduce the risk to acceptable limits. These concepts, as well as other design alternatives, are described and evaluated.

  7. Performance and Flowfield Measurements on a 10-inch Ducted Rotor VTOL UAV

    Science.gov (United States)

    Martin, Preston; Tung, Chee

    2004-01-01

    A ducted fan VTOL UAV with a 10-inch diameter rotor was tested in the US Army 7-by 10-Foot Wind Tunnel. The test conditions covered a range of angle of attack from 0 to 110 degrees to the freestream. The tunnel velocity was varied from 0 (simulating a hover condition) to 128 ft/sec in propeller mode. A six-component internal balance measured the aerodynamic loads for a range of model configurations. including the isolated rotor, the isolated duct, and the full configuration of the duct and rotor. For some conditions, hotwire velocity surveys were conducted along the inner and outer surface of the duct and across the downstream wake. In addition, fluorescent oil flow visualization allowed the flow separation patterns inside and outside of the duct to be mapped for a few test conditions. Two different duct shapes were tested to determine the performance effects of leading edge radius. For each duct, a range of rotor tip gap from 1%R to 4.5%R was tested to determine the performance penalty in hover and axial flight. Measured results are presented in terms of hover performance, hover performance in a crosswind, and high angle of attack performance in propeller mode. In each case, the effects of both tip gap and duct leading edge radius are illustrated using measurements. Some of the hover performance issues were also studied using a simple analytical method, and the results agreed with the measurements.

  8. Experimental performance of an internal resistance heater for Langley 6-inch expansion tube driver

    Science.gov (United States)

    Creel, T. R., Jr.

    1972-01-01

    An experimental investigation of the heating characteristics of an internal resistance heating element was conducted in the driver of the Langley 6-inch expansion tube to obtain actual operating conditions, to compare these results to theory, and to determine whether any modification need be made to the heater element. The heater was operated in pressurized helium from 138. MN/sq m to 62.1 MN/sq m. This investigation revealed large temperature variations within the heater element caused primarily by area reductions at insulator locations. These large temperature variations were reduced by welding small tabs over all grooves. Previous predictions of heater element and driver gas temperature were unacceptable so new equations were derived. These equations predict element and gas temperature within 10 percent of the test data when either the constant power cycle or the interrupted power cycle is used. Visual observation of the heater element, when exposed to the atmosphere with power on, resulted in a decision to limit the heater element to 815 K. Experimental shock Mach numbers are in good agreement with theory.

  9. Summary of LaRC 2-inch Erectable Joint Hardware Heritage Test Data

    Science.gov (United States)

    Dorsey, John T.; Watson, Judith J.

    2016-01-01

    As the National Space Transportation System (STS, also known as the Space Shuttle) went into service during the early 1980's, NASA envisioned many missions of exploration and discovery that could take advantage of the STS capabilities. These missions included: large orbiting space stations, large space science telescopes and large spacecraft for manned missions to the Moon and Mars. The missions required structures that were significantly larger than the payload volume available on the STS. NASA Langley Research Center (LaRC) conducted studies to design and develop the technology needed to assemble the large space structures in orbit. LaRC focused on technology for erectable truss structures, in particular, the joint that connects the truss struts at the truss nodes. When the NASA research in large erectable space structures ended in the early 1990's, a significant amount of structural testing had been performed on the LaRC 2-inch erectable joint that was never published. An extensive set of historical information and data has been reviewed and the joint structural testing results from this historical data are compiled and summarized in this report.

  10. Design evaluation of the 20-cm (8-inch) secondary burner system

    International Nuclear Information System (INIS)

    Rode, J.S.

    1977-08-01

    This report describes an evaluation of the design of the existing 20-cm (8-inch) engineering-scale secondary burner system in the HTGR reprocessing cold pilot plant at General Atomic Co. The purpose of this evaluation is to assess the suitability of the existing design as a prototype of the HTGR Recycle Demonstration Facility (HRDF) secondary burner system and to recommend alternatives where the existing design is thought to be unsuitable as a prototype. This evaluation has led to recommendations for the parallel development of two integrated design concepts for a prototype secondary burner system. One concept utilizes the existing burner heating and cooling subsystems in order to minimize development risk, but simplifies a number of other features associated with remote maintenance and burner operation. The other concept, which offers maximum cost reduction, utilizes internal gas cooling of the burner, retains the existing heating subsystem for design compatibility, but requires considerable development to reduce the risk to acceptable limits. These concepts, as well as other design alternatives, are described and evaluated

  11. Development of the Software for 30 inch Telescope Control System at KHAO

    Science.gov (United States)

    Mun, B.-S.; Kim, S.-J.; Jang, M.; Min, S.-W.; Seol, K.-H.; Moon, K.-S.

    2006-12-01

    Even though 30inch optical telescope at Kyung Hee Astronomy Observatory has been used to produce a series of scientific achievements since its first light in 1992, numerous difficulties in the operation of the telescope have hindered the precise observations needed for further researches. Since the currently used PC-TCS (Personal Computer based Telescope Control system) software based on ISA-bus type is outdated, it doesn't have a user friendly interface and make it impossible to scale. Also accumulated errors which are generated by discordance from input and output signals into a motion controller required new control system. Thus we have improved the telescope control system by updating software and modifying mechanical parts. We applied a new BLDC (brushless DC) servo motor system to the mechanical parts of the telescope and developed a control software using Visual Basic 6.0. As a result, we could achieve a high accuracy in controlling of the telescope and use the userfriendly GUI (Graphic User Interface).

  12. Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture.

    Science.gov (United States)

    Jang, Dae-Eun; Lee, Ji-Young; Jang, Hyun-Seon; Lee, Jang-Jae; Son, Mee-Kyoung

    2015-08-01

    The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

  13. Formation of Methyl Acrylate from CO 2 and Ethylene via Methylation of Nickelalactones

    KAUST Repository

    Bruckmeier, Christian

    2010-05-24

    The nickel-induced coupling of ethylene and CO2 represents a promising pathway toward acrylates. To overcome the high bond dissociation energies of the M-O moieties, we worked out an in situ methylation of nickelalactones to realize the β-hydride elimination and the liberation of the acrylate species. © 2010 American Chemical Society.

  14. Synthesis of Radiation Curable Palm Oil-Based Epoxy Acrylate: NMR and FTIR Spectroscopic Investigations.

    Science.gov (United States)

    Salih, Ashraf M; Ahmad, Mansor Bin; Ibrahim, Nor Azowa; Dahlan, Khairul Zaman Hj Mohd; Tajau, Rida; Mahmood, Mohd Hilmi; Yunus, Wan Md Zin Wan

    2015-08-04

    Over the past few decades, there has been an increasing demand for bio-based polymers and resins in industrial applications, due to their potential lower cost and environmental impact compared with petroleum-based counterparts. The present research concerns the synthesis of epoxidized palm oil acrylate (EPOLA) from an epoxidized palm oil product (EPOP) as environmentally friendly material. EPOP was acrylated by acrylic acid via a ring opening reaction. The kinetics of the acrylation reaction were monitored throughout the reaction course and the acid value of the reaction mixture reached 10 mg KOH/g after 16 h, indicating the consumption of the acrylic acid. The obtained epoxy acrylate was investigated intensively by means of FTIR and NMR spectroscopy, and the results revealed that the ring opening reaction was completed successfully with an acrylation yield about 82%. The UV free radical polymerization of EPOLA was carried out using two types of photoinitiators. The radiation curing behavior was determined by following the conversion of the acrylate groups. The cross-linking density and the hardness of the cured EPOLA films were measured to evaluate the effect of the photoinitiator on the solid film characteristics, besides, the thermal and mechanical properties were also evaluated.

  15. Enzyme-Catalyzed Synthesis of Saccharide Acrylate Monomers from Nonedible Biomass

    NARCIS (Netherlands)

    Kloosterman, Wouter M. J.; Brouwer, Sander; Loos, Katja

    Various cellulase preparations were found to catalyze the transglycosidation between cotton linters and 2-hydroxyethyl acrylate. The conversion and enzyme activity were found to be optimal in reaction mixtures that contained 5 vol% of the acrylate. The structures of the products were revealed by

  16. Contact-killing of adhering streptococci by a quaternary ammonium compound incorporated in an acrylic resin

    NARCIS (Netherlands)

    Mei, Li; Ren, Yijin; Loontjens, Ton J. A.; van der Mei, Henny C.; Busscher, Henk J.

    2012-01-01

    Purpose: Acrylates for bonding of joint prostheses and stainless-steel brackets in orthopedics and orthodontics are prone to bacterial adhesion and biofilm formation, respectively, leading to serious infectious complications. Here we describe the preparation of a contact-killing acrylic resin by

  17. Neutral, anionic, cationic, and zwitterionic diblock copolymers featuring poly(2-methoxyethyl acrylate) hydrophobic segments

    DEFF Research Database (Denmark)

    Javakhishvili, Irakli; Jankova Atanasova, Katja; Hvilsted, Søren

    2013-01-01

    ), and zwitterionic poly(3-(N-(2-methacryloyloxyethyl)-N,N- dimethylammonio)propane sulfonate) (PDMAPS) blocks are constructed. mPEG, poly(tert-butyl acrylate) (PtBA), and poly(tert-butyl methacrylate) (PtBMA) macroinitiators are chain extended with 2-methoxyethyl acrylate (MEA) employing copper-mediated atom...

  18. Use of an acrylic mold for mortise view improvement in ankle fractures: a feasibility study

    NARCIS (Netherlands)

    Donken, C.C.M.A.; Verhofstad, M.H.J.; Edwards, M.J.R.; Schoemaker, M.C.; Laarhoven, C.J.H.M. van

    2011-01-01

    We investigated an acrylic mold for use in obtaining ankle radiographs in 31 consecutive patients with ankle fracture. The radiologic examination consisted of routine lateral and mortise views, with the same views procured with the use of the acrylic mold to position the ankle. Radiographic evidence

  19. Heat-cured Acrylic Resin versus Light-activated Resin: A Patient ...

    African Journals Online (AJOL)

    Context: Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed ...

  20. Synthesis of Radiation Curable Palm Oil–Based Epoxy Acrylate: NMR and FTIR Spectroscopic Investigations

    Directory of Open Access Journals (Sweden)

    Ashraf M. Salih

    2015-08-01

    Full Text Available Over the past few decades, there has been an increasing demand for bio-based polymers and resins in industrial applications, due to their potential lower cost and environmental impact compared with petroleum-based counterparts. The present research concerns the synthesis of epoxidized palm oil acrylate (EPOLA from an epoxidized palm oil product (EPOP as environmentally friendly material. EPOP was acrylated by acrylic acid via a ring opening reaction. The kinetics of the acrylation reaction were monitored throughout the reaction course and the acid value of the reaction mixture reached 10 mg KOH/g after 16 h, indicating the consumption of the acrylic acid. The obtained epoxy acrylate was investigated intensively by means of FTIR and NMR spectroscopy, and the results revealed that the ring opening reaction was completed successfully with an acrylation yield about 82%. The UV free radical polymerization of EPOLA was carried out using two types of photoinitiators. The radiation curing behavior was determined by following the conversion of the acrylate groups. The cross-linking density and the hardness of the cured EPOLA films were measured to evaluate the effect of the photoinitiator on the solid film characteristics, besides, the thermal and mechanical properties were also evaluated.

  1. Evaluation of Packed Distillation Columns I - Atmospheric Pressure

    National Research Council Canada - National Science Library

    Reynolds, Thaine

    1951-01-01

    .... Four column-packing combinations of the glass columns and four column-packing combinations of the steel columns were investigated at atmospheric pressure using a test mixture of methylcyclohexane...

  2. Development of radiation curable surface coating based on soybean oil. part I. preparation and characterization of acrylated oil

    International Nuclear Information System (INIS)

    Ibrahim, M.S.; Said, H.M.; Moussa, I.M.

    2005-01-01

    An epoxy acrylate was synthesized from epoxidized soybean oil (ESOL) by using acrylic acid monomer. Triethyl amine (TEA) and hydroquinone were used as catalyst and inhibitor respectively. The epoxidized soybean oil acrylate (ESOLA) is done by introducing acrylic acid into oxirane groups of the epoxidized oil (ESOL). This reaction was confirmed by analytical data in terms of oxirane oxygen content, acid value, viscosity and spectroscopically analysis

  3. The transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion

    Directory of Open Access Journals (Sweden)

    Devi Rianti

    2006-12-01

    Full Text Available A laboratoric experimental study was conducted on the transverse strength of acrylic resin after Coleus amboinicus, Lour extract solution immersion. The aim of this study is to know the difference of acrylic resin transverse strengths caused by immersion time variations in a concentrate solution. The study was carried out on unpolished acrylic resin plates with 65 × 10 × 2,5 mm dimension; solution with 15% Coleus amboinicus, Lour extract, and 30, 60, 90 days immersion times to measure the transverse strength and sterilized aquadest was used as control. Acrylic resin plates transverse strength was measured using Autograph AG-10 TE. The data was analyzed using One-Way Anova and LSD with 5% degree of significance. The result showed that longer immersion time will decrease the transverse strength of the acrylic resin plates. After 90 days immersion time, the transverse strength decrease is still above the recommended standard transverse strength.

  4. Effect of disinfectant solutions on a denture base acrylic resin.

    Science.gov (United States)

    Carvalho, Cristiane F; Vanderlei, Aleska D; Marocho, Susana M Salazar; Pereira, Sarina M B; Nogueira, Lafayette; Paes-Júnior, Tarcisio J Arruda

    2012-01-01

    The aim of this study was to evaluate the hardness, roughness and mass loss of an acrylic denture base resin after in vitro exposure to four disinfectant solutions. Forty specimens (Clássico, Brazil) were prepared and randomly assigned to 4 groups n = 10) according to the disinfectant solution: G1: control, stored in distilled water at 37 degrees C; G2: 1% sodium hypochlorite; G3: 2% glutaraldehyde; G4: 4% chlorhexidine. G2 to G4 were immersed for 60 minutes in the disinfectant solution. Measurements were carried out both before and after immersion in the solution. The surface was analyzed with a surface roughness tester (Surfcorder SE 1700 KOZAKALAB), a microdurometer FM-700 (Future Tech) and a scanning electron microscope (DSM 962-ZEISS). Loss of mass was determined with a digital weighing scale. After disinfection procedures, values were analyzed statistically. The acrylic denture base resin may be vulnerable to surface changes after in vitro immersion in the disinfectant solutions studied.

  5. The adhesion of modern soft relining materials to acrylic dentures.

    Science.gov (United States)

    Więckiewicz, Włodzimierz; Kasperski, Jacek; Więckiewicz, Mieszko; Miernik, Marta; Król, Wojciech

    2014-01-01

    Silicone-based liners are widespread materials in prosthetic dentistry. Their mechanical properties have to meet several key requirements such as adequate adhesion to denture base polymers in order to provide right function of masticatory system and oral hygiene. The aim of this paper was to evaluate and compare tensile and shear bond strengths values of three modern autopolimeryzed silicone relining materials bonded to acrylic plates. Three silicone-based soft relining materials were investigated in this study (A-Soft Line 30, Bosworth Dentusil and Elite Super Soft). A total of 78 specimens were prepared: 13 of each material (total: 39) for testing tensile bond strength and 13 of each material for testing shear bond strength (total: 39). The obtained data were analyzed statistically. The average tensile bond strength results were 0.86 MPa for Bosworth Dentusil, 1.00 MPa for Elite Super Soft and 1.25 MPa for A-Soft Line 30. The silicone-based relining materials had different average values of shear bond strength: 0.67 MPa Elite Super Soft; 1.32 MPa A-Soft Line 30 and 1.57 MPa Bosworth Dentusil. As the result of the study it can be concluded that all tested materials have acceptable adhesion values to acrylic resin. According to tensile and shear bond strengths tests the best adhesive properties has A-Soft Line 30.

  6. Dissipation factor of acrylic dielectric elastomer--an experimental study.

    Science.gov (United States)

    Sahu, Raj Kumar; Pramanik, Bipul; Patra, Karali; Bhaumik, Shovan; Pandey, Arvind Kumar; Setua, Dipak Kumar

    2014-10-01

    This paper studies the effects of frequency, pre-strain and electrode types on the dielectric property of a commercially available and most widely used acrylic elastomer, VHB 4910. The acrylic VHB film is pre-stretched in biaxial directions with the help of an in-house developed biaxial stretching device. The stretched film has been sandwiched between two card board frames to prepare samples of different pre-stretch values. Three different types of electrodes namely copper tape, silver grease and carbon grease have been pasted on the both sides of prestretched samples. Dissipation factor of pre-stretched and electrode adhered VHB sample has been experimentally determined at different frequency (upto 1 MHz) of input voltage using a LCR meter. Experimental results on the variation of dissipation factor with pre-straining, frequency (low to high) and electrode types are reported. The dissipation factor value is further used to estimate electrical efficiency at different biaxial pre-straining, frequency and electrode types.

  7. Thin film of Poly(acrylic acid-co-allyl acrylate as a Sacrificial Protective Layer for Hydrophilic Self Cleaning Glass

    Directory of Open Access Journals (Sweden)

    Jānis Lejnieks

    2010-05-01

    Full Text Available Poly(acrylic acid-co-allyl acrylate statistical copolymers were synthesized in a controlled manner in two steps: first tert.butyl acrylate and allyl acrylate were polymerized via atom transfer radical polymerization (ATRP and afterwords the tert.butyl protective groups were removed via hydrolysis. Samples of self cleaning glass (SCG were coated with thin films of poly(acrylic acid-co-allyl acrylate and cross-linked afterwards by UV irradiation (in the presence of a photoinitiator and an accelerator. Solution cast thin films were transparent and homogeneous before and after UV cross-linking. The irradiated samples were found to be hydrophilic (Θ < 20° and water insoluble. The coating prevented the spontaneous hydrophobization of the SCG by residual silicon exhaled from the sealing material. The TiO2 photocatalyst that covers the glass surface was found to strip the protective coating. The rate of the photooxidation process was measured by IR spectroscopy. The real field performance of the protective coating was also tested.

  8. Biogeochemistry of Dimethylsulfide, Dimethylsulfoniopropionate, and Acrylic Acid in the Changjiang Estuary and the East China Sea

    Science.gov (United States)

    Wu, Xi; Li, Pei-Feng; Liu, Chun-Ying; Zhang, Hong-Hai; Yang, Gui-Peng; Zhang, Sheng-Hui; Zhu, Mao-Xu

    2017-12-01

    The distributions of dimethylsulfide (DMS), dimethylsulfoniopropionate (DMSP), and acrylic acid (AA) were investigated in the Changjiang Estuary during winter (dry season) and summer (wet season) 2014 and in the East China Sea (ECS) during summer 2015. The rates of dissolved DMSP (DMSPd) degradation with DMS and AA production, DMS degradation, and AA degradation in the ECS were also studied. Significant seasonal variations in DMS(P) and AA concentrations were observed in the Changjiang Estuary with higher values during the wet season than during the dry season. The maximum ratio of AA/chlorophyll a (Chl a) occurred at the mouth of the Changjiang Estuary due to the combined effects of production from DMSP and terrestrial inputs from the Changjiang Estuary. The distributions of DMS(P) and AA in the ECS were dramatically influenced by the Kuroshio Current and the upwelling caused by the Taiwan Warm Current. The ratios of DMS(P)/Chl a and AA/Chl a exhibited similar patterns in the surface seawater of the ECS, which indicated that phytoplankton species and biomass might play important roles in controlling the distributions of DMS(P) and AA. In vertical profiles, high values of AA emerged in the upper water column and bottom seawater of the Changjiang Estuary. Meanwhile, the maxima of DMS(P) and AA generally appeared in the surface or euphotic layer, whereas their minima arose in the bottom seawater of the ECS. The degradation rates of DMSPd, DMS, and AA in the inshore waters were higher than those in the open sea.

  9. Oscillating water column structural model

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, Guild [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bull, Diana L [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jepsen, Richard Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gordon, Margaret Ellen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    An oscillating water column (OWC) wave energy converter is a structure with an opening to the ocean below the free surface, i.e. a structure with a moonpool. Two structural models for a non-axisymmetric terminator design OWC, the Backward Bent Duct Buoy (BBDB) are discussed in this report. The results of this structural model design study are intended to inform experiments and modeling underway in support of the U.S. Department of Energy (DOE) initiated Reference Model Project (RMP). A detailed design developed by Re Vision Consulting used stiffeners and girders to stabilize the structure against the hydrostatic loads experienced by a BBDB device. Additional support plates were added to this structure to account for loads arising from the mooring line attachment points. A simplified structure was designed in a modular fashion. This simplified design allows easy alterations to the buoyancy chambers and uncomplicated analysis of resulting changes in buoyancy.

  10. REDISTRIBUTOR FOR LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Bradley, J.G.

    1957-10-29

    An improved baffle plate construction to intimately mix immiscible liquid solvents for solvent extraction processes in a liquid-liquid pulse column is described. To prevent the light and heavy liquids from forming separate continuous homogeneous vertical channels through sections of the column, a baffle having radially placed rectangular louvers with deflection plates opening upon alternate sides of the baffle is placed in the column, normal to the axis. This improvement substantially completely reduces strippiig losses due to poor mixing.

  11. Structural design of isolated column footings

    Directory of Open Access Journals (Sweden)

    Fathi Abdrabbo

    2016-09-01

    The study showed that shear span to depth ratio of a footing and distributions of contact stress at footing–soil interface are key factors in the structural design of the footing. ECP203-11, ACI318-08, and EC2-2004 code provisions, underestimate the structural failure loads of isolated column footings, while BS 8110.1-1997 overpredicts the failure loads of isolated column footings, if punching provisions at perimeter of column are pulled out from the code.

  12. Computational fluid dynamics analysis of space shuttle main propulsion feed line 17-inch disconnect valves

    Science.gov (United States)

    Kandula, Max; Pearce, Daniel

    1989-01-01

    A steady incompressible three-dimensional (3-D) viscous flow analysis was conducted for the Space Shuttle Main Propulsion External Tank (ET)/Orbiter (ORB) propellant feed line quick separable 17-inch disconnect flapper valves for liquid oxygen (LO2) and liquid hydrogen (LH2). The main objectives of the analysis were to predict and correlate the hydrodynamic stability of the flappers and pressure drop with available water test data. Computational Fluid Dynamics (CFD) computer codes were procured at no cost from the public domain, and were modified and extended to carry out the disconnect flow analysis. The grid generator codes SVTGD3D and INGRID were obtained. NASA Ames Research Center supplied the flow solution code INS3D, and the color graphics code PLOT3D. A driver routine was developed to automate the grid generation process. Components such as pipes, elbows, and flappers can be generated with simple commands, and flapper angles can be varied easily. The flow solver INS3D code was modified to treat interior flappers, and other interfacing routines were developed, which include a turbulence model, a force/moment routine, a time-step routine, and initial and boundary conditions. In particular, an under-relaxation scheme was implemented to enhance the solution stability. Major physical assumptions and simplifications made in the analysis include the neglect of linkages, slightly reduced flapper diameter, and smooth solid surfaces. A grid size of 54 x 21 x 25 was employed for both the LO2 and LH2 units. Mixing length theory applied to turbulent shear flow in pipes formed the basis for the simple turbulence model. Results of the analysis are presented for LO2 and LH2 disconnects.

  13. Thermally stable dexsil-400 glass capillary columns

    International Nuclear Information System (INIS)

    Maskarinec, M.P.; Olerich, G.

    1980-01-01

    The factors affecting efficiency, thermal stability, and reproducibility of Dexsil-400 glass capillary columns for gas chromatography in general, and for polycyclic aromatic hydrocarbons (PAHs) in particular were investigated. Columns were drawn from Kimble KG-6 (soda-lime) glass or Kimox (borosilicate) glass. All silylation was carried out at 200 0 C. Columns were coated according to the static method. Freshly prepared, degassed solutions of Dexsil-400 in pentane or methylene chloride were used. Thermal stability of the Dexsil 400 columns with respect to gas chromatography/mass spectrometry (GC/MS) were tested. Column-to-column variability is a function of each step in the fabrication of the columns. The degree of etching, extent of silylation, and stationary phase film thickness must be carefully controlled. The variability in two Dexsil-400 capillary column prepared by etching, silylation with solution of hexa methyl disilazone (HMDS), and static coating is shown and also indicates the excellent selectivity of Dexsil-400 for the separation of alkylated aromatic compounds. The wide temperature range of Dexsil-400 and the high efficiency of the capillary columns also allow the analysis of complex mixtures with minimal prefractionation. Direct injection of a coal liquefaction product is given. Analysis by GC/MS indicated the presence of parent PAHs, alkylated PAHs, nitrogen and sulfur heterocycles, and their alkylated derivatives. 4 figures

  14. Preparation and application of hydrophilic monolithic columns.

    Science.gov (United States)

    Jiang, Zhengjin; Smith, Norman William; Liu, Zhenghua

    2011-04-29

    Hydrophilic interaction chromatography (HILIC) has experienced increasing attention in recent years. Much research has been carried out in the area of HILIC separation mechanisms, column techniques and applications. Because of their good permeability, low resistance to mass transfer and easy preparation within capillaries, hydrophilic monolithic columns represent a trend among novel HILIC column techniques. This review attempts to present an overview of the preparation and applications of HILIC monolithic columns carried out in the past decade. The separation mechanism of various hydrophilic monolithic stationary phases is also reviewed. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Surfactant and counter-ion distribution in styrene-butyl acrylate-acrylic acid dry latex submonolayers

    Directory of Open Access Journals (Sweden)

    Keslarek Amauri José

    2004-01-01

    Full Text Available Styrene-butyl acrylate-acrylic acid latex submonolayers prepared using a non-reactive phosphate surfactant together with a reactive sulfonate surfactant were examined in a transmission microscope using electron energy loss spectroscopy imaging (ESI-TEM. Phosphorus is nearly absent from the particles core but it is detected in a thick shell and in unusual, strongly scattering structures with a low carbon content, and largely made out of inorganic phosphate. P is also dispersed outside the particles, while S is uniformly distributed within then. The Na and N elemental maps show that the respective monovalent ions (Na+ and NH4+ have different distributions, in the latex: Na signal within the particles is stronger than in the background, while N is accumulated at the particle borders. The distributions of surfactant and counter-ions are thus different from some current assumptions, but they support recent results on the distribution of ionic constituents in latex films, by scanning electric potential microscopy.

  16. Synthesis of Highly Porous Poly(tert-butyl acrylate)-b-polysulfone-b-poly(tert-butyl acrylate) Asymmetric Membranes

    KAUST Repository

    Xie, Yihui

    2016-03-24

    For the first time, self-assembly and non-solvent induced phase separation was applied to polysulfone-based linear block copolymers, reaching mechanical stability much higher than other block copolymers membranes used in this method, which were mainly based on polystyrene blocks. Poly(tert-butyl acrylate)-b-polysulfone-b-poly(tert-butyl acrylate) (PtBA30k-b-PSU14k-b-PtBA30k) with a low polydispersity of 1.4 was synthesized by combining step-growth condensation and RAFT polymerization. Various advanced electron microscopies revealed that PtBA30k-b-PSU14k-b-PtBA30k assembles into worm-like cylindrical micelles in DMAc and adopts a “flower-like” arrangement with the PSU central block forming the shell. Computational modeling described the mechanism of micelle formation and morphological transition. Asymmetric nanostructured membranes were obtained with a highly porous interconnected skin layer and a sublayer with finger-like macrovoids. Ultrafiltration tests confirmed a water permeance of 555 L m-2 h-1 bar-1 with molecular weight cut-off of 28 kg/mol. PtBA segments on the membrane surface were then hydrolyzed and complexed with metals, leading to cross-linking and enhancement of antibacterial capability.

  17. Specific Yield--Column drainage and centrifuge moisture content

    Science.gov (United States)

    Johnson, A.I.; Prill, R.C.; Morris, D.A.

    1963-01-01

    The specific yield of a rock or soil, with respect to water, is the ratio of (1) the volume of water which, after being saturated, it will yield by gravity to (2) its own volume. Specific retention represents the water retained against gravity drainage. The specific yield and retention when added together are equal to the total interconnected porosity of the rock or soil. Because specific retention is more easily determined than specific yield, most methods for obtaining yield first require the determination of specific retention. Recognizing the great need for developing improved methods of determining the specific yield of water-bearing materials, the U.S. Geological Survey and the California Department of Water Resources initiated a cooperative investigation of this subject. The major objectives of this research are (1) to review pertinent literature on specific yield and related subjects, (2) to increase basic knowledge of specific yield and rate of drainage and to determine the most practical methods of obtaining them, (3) to compare and to attempt to correlate the principal laboratory and field methods now commonly used to obtain specific yield, and (4) to obtain improved estimates of specific yield of water-bearing deposits in California. An open-file report, 'Specific yield of porous media, an annotated bibliography,' by A. I. Johnson, D. A. Morris, and R. C. Prill, was released in 1960 in partial fulfillment of the first objective. This report describes the second phase of the specific-yield study by the U.S. Geological Survey Hydrologic Laboratory at Denver, Colo. Laboratory research on column drainage and centrifuge moisture equivalent, two methods for estimating specific retention of porous media, is summarized. In the column-drainage study, a wide variety of materials was packed into plastic columns of 1- to 8-inch diameter, wetted with Denver tap water, and drained under controlled conditions of temperature and humidity. The effects of cleaning the

  18. The photocatalytic enhancement of acrylic and PET solar water disinfection (SODIS) bottles.

    Science.gov (United States)

    Carey, J M; Perez, T M; Arsiaga, E G; Loetscher, L H; Boyd, J E

    2011-01-01

    The solar water disinfection method (SODIS) was modified by the addition of a photocatalytic layer of titania on the interior surface of polyethylene terephthalate (PET) and acrylic bottles. Titania was solvent deposited on the interior of commercially available PET bottles, as well as bottles that were constructed from acrylic. Uncoated and titania-coated acrylic bottles removed 3,000,000-5,000,000 colony forming units per milliliter of K12 E. coli from 670 mL of contaminated water in 40 min of solar irradiance. After five hours of sunlight exposure, the concentration of 10 ppm methyl orange (a representative organic water contaminant), was reduced by 61% using the titania-coated acrylic bottles. The concentration of 87 ppb microcystin-LR (a representative algal toxin) was reduced by 70% after 7 hours of sunlight exposure in the titania-coated acrylic bottles. Acrylic is an effective alternative to PET for use in the SODIS method due to its greater UV transparency. The addition of titania to PET and acrylic bottles confers the ability to remove chemical contaminants in addition to inactivating microbiological contaminants.

  19. Gel polymer electrolytes based on nanofibrous polyacrylonitrile–acrylate for lithium batteries

    International Nuclear Information System (INIS)

    Kim, Dul-Sun; Woo, Jang Chang; Youk, Ji Ho; Manuel, James; Ahn, Jou-Hyeon

    2014-01-01

    Graphical abstract: - Highlights: • Nanofibrous polyacrylonitrile–acrylate membranes were prepared by electrospinning. • Trimethylolpropane triacrylate was used as a crosslinking agent of fibers. • The GPE based on PAN–acrylate (1/0.5) showed good electrochemical properties. - Abstract: Nanofibrous membranes for gel polymer electrolytes (GPEs) were prepared by electrospinning a mixture of polyacrylonitrile (PAN) and trimethylolpropane triacrylate (TMPTA) at weight ratios of 1/0.5 and 1/1. TMPTA is used to achieve crosslinking of fibers thereby improving mechanical strength. The average fiber diameters increased with increasing TMPTA concentration and the mechanical strength was also improved due to the enhanced crosslinking of fibers. GPEs based on electrospun membranes were prepared by soaking them in a liquid electrolyte of 1 M LiPF 6 in ethylene carbonate (EC)/dimethyl carbonate (DMC) (1:1, v/v). The electrolyte uptake and ionic conductivity of GPEs based on PAN and PAN–acrylate (weight ratio; 1/1 and 1/0.5) were investigated. Ionic conductivity of GPEs based on PAN–acrylate was the highest for PAN/acrylate (1/0.5) due to the proper swelling of fibers and good affinity with liquid electrolyte. Both GPEs based on PAN and PAN–acrylate membranes show good oxidation stability, >5.0 V vs. Li/Li + . Cells with GPEs based on PAN–acrylate (1/0.5) showed remarkable cycle performance with high initial discharge capacity and low capacity fading

  20. Gel polymer electrolytes based on nanofibrous polyacrylonitrile–acrylate for lithium batteries

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dul-Sun [Department of Chemical and Biological Engineering, Research Institute for Green Energy Convergence Technology, Gyeongsang National University, 900 Gajwa-dong, Jinju 660-701 (Korea, Republic of); Woo, Jang Chang [Department of Textile Engineering, Inha University, 100 Inharo, Nam-gu Incheon 402-751 (Korea, Republic of); Youk, Ji Ho, E-mail: youk@inha.ac.kr [Department of Textile Engineering, Inha University, 100 Inharo, Nam-gu Incheon 402-751 (Korea, Republic of); Manuel, James [Department of Chemical and Biological Engineering, Research Institute for Green Energy Convergence Technology, Gyeongsang National University, 900 Gajwa-dong, Jinju 660-701 (Korea, Republic of); Ahn, Jou-Hyeon, E-mail: jhahn@gnu.ac.kr [Department of Chemical and Biological Engineering, Research Institute for Green Energy Convergence Technology, Gyeongsang National University, 900 Gajwa-dong, Jinju 660-701 (Korea, Republic of); Department of Materials Engineering and Convergence Technology, Gyeongsang National University, 900 Gajwa-dong, Jinju 660-701 (Korea, Republic of)

    2014-10-15

    Graphical abstract: - Highlights: • Nanofibrous polyacrylonitrile–acrylate membranes were prepared by electrospinning. • Trimethylolpropane triacrylate was used as a crosslinking agent of fibers. • The GPE based on PAN–acrylate (1/0.5) showed good electrochemical properties. - Abstract: Nanofibrous membranes for gel polymer electrolytes (GPEs) were prepared by electrospinning a mixture of polyacrylonitrile (PAN) and trimethylolpropane triacrylate (TMPTA) at weight ratios of 1/0.5 and 1/1. TMPTA is used to achieve crosslinking of fibers thereby improving mechanical strength. The average fiber diameters increased with increasing TMPTA concentration and the mechanical strength was also improved due to the enhanced crosslinking of fibers. GPEs based on electrospun membranes were prepared by soaking them in a liquid electrolyte of 1 M LiPF{sub 6} in ethylene carbonate (EC)/dimethyl carbonate (DMC) (1:1, v/v). The electrolyte uptake and ionic conductivity of GPEs based on PAN and PAN–acrylate (weight ratio; 1/1 and 1/0.5) were investigated. Ionic conductivity of GPEs based on PAN–acrylate was the highest for PAN/acrylate (1/0.5) due to the proper swelling of fibers and good affinity with liquid electrolyte. Both GPEs based on PAN and PAN–acrylate membranes show good oxidation stability, >5.0 V vs. Li/Li{sup +}. Cells with GPEs based on PAN–acrylate (1/0.5) showed remarkable cycle performance with high initial discharge capacity and low capacity fading.

  1. Antimicrobial activity of a quaternary ammonium methacryloxy silicate-containing acrylic resin: a randomised clinical trial.

    Science.gov (United States)

    Liu, Si-ying; Tonggu, Lige; Niu, Li-na; Gong, Shi-qiang; Fan, Bing; Wang, Liguo; Zhao, Ji-hong; Huang, Cui; Pashley, David H; Tay, Franklin R

    2016-02-23

    Quaternary ammonium methacryloxy silicate (QAMS)-containing acrylic resin demonstrated contact-killing antimicrobial ability in vitro after three months of water storage. The objective of the present double-blind randomised clinical trial was to determine the in vivo antimicrobial efficacy of QAMS-containing orthodontic acrylic by using custom-made removable retainers that were worn intraorally by 32 human subjects to create 48-hour multi-species plaque biofilms, using a split-mouth study design. Two control QAMS-free acrylic disks were inserted into the wells on one side of an orthodontic retainer, and two experimental QAMS-containing acrylic disks were inserted into the wells on the other side of the same retainer. After 48 hours, the disks were retrieved and examined for microbial vitality using confocal laser scanning microscopy. No harm to the oral mucosa or systemic health occurred. In the absence of carry-across effect and allocation bias (disks inserted in the left or right side of retainer), significant difference was identified between the percentage kill in the biovolume of QAMS-free control disks (3.73 ± 2.11%) and QAMS-containing experimental disks (33.94 ± 23.88%) retrieved from the subjects (P ≤ 0.001). The results validated that the QAMS-containing acrylic exhibits favourable antimicrobial activity against plaque biofilms in vivo. The QAMS-containing acrylic may also be used for fabricating removable acrylic dentures.

  2. Antimicrobial properties of acrylic resins for dentures impregnated with silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Gligorijević Nikola

    2017-01-01

    Full Text Available Introduction. Porosity and surface adherence of acrylates make them collectors of infectious content from the mouth. This applies particularly to cold-curable acrylates, whose structure is less compact. The aim of this study was to investigate the antimicrobial effects of cold polymerized dental acrylics after impregnation with silver nanoparticles. Material and Methods. Different concentrations (2%, 5% and 10% of silver nanoparticles were added to the polymer components (powder of cold polymerizing acrylate, after which disk-shaped samples, 10 mm, in diameter, were made. A disk of silver nanoparticles was used as a control for our study. Antimicrobial activity was investigated using the disc diffusion method on the two most common oral cavity infecting agents - Gram positive bacterium, Staphylococcus aureus ATCC 25923, and fungus Candida albicans ATCC 2091. The results have shown that the control sample as well as the samples of silver impregnated acrylics resins exhibit antibacterial activity. The growth zone inhibition of Staphylococcus aureus in the culture medium is proportional to the concentration of silver nanoparticles in the cold curing acrylic resin. On the other hand, the test samples did not inhibit the growth of Candida albicans in the medium. Conclusion. Silver nanoparticles in cold curing acrylic resin demonstrated antibacterial activity. Expanding their antimicrobial spectrum of activity and their potential clinical application will be the subject of the future research.

  3. Antimicrobial activity of a quaternary ammonium methacryloxy silicate-containing acrylic resin: a randomised clinical trial

    Science.gov (United States)

    Liu, Si-ying; Tonggu, Lige; Niu, Li-na; Gong, Shi-qiang; Fan, Bing; Wang, Liguo; Zhao, Ji-hong; Huang, Cui; Pashley, David H.; Tay, Franklin R.

    2016-01-01

    Quaternary ammonium methacryloxy silicate (QAMS)-containing acrylic resin demonstrated contact-killing antimicrobial ability in vitro after three months of water storage. The objective of the present double-blind randomised clinical trial was to determine the in vivo antimicrobial efficacy of QAMS-containing orthodontic acrylic by using custom-made removable retainers that were worn intraorally by 32 human subjects to create 48-hour multi-species plaque biofilms, using a split-mouth study design. Two control QAMS-free acrylic disks were inserted into the wells on one side of an orthodontic retainer, and two experimental QAMS-containing acrylic disks were inserted into the wells on the other side of the same retainer. After 48 hours, the disks were retrieved and examined for microbial vitality using confocal laser scanning microscopy. No harm to the oral mucosa or systemic health occurred. In the absence of carry-across effect and allocation bias (disks inserted in the left or right side of retainer), significant difference was identified between the percentage kill in the biovolume of QAMS-free control disks (3.73 ± 2.11%) and QAMS-containing experimental disks (33.94 ± 23.88%) retrieved from the subjects (P ≤ 0.001). The results validated that the QAMS-containing acrylic exhibits favourable antimicrobial activity against plaque biofilms in vivo. The QAMS-containing acrylic may also be used for fabricating removable acrylic dentures. PMID:26903314

  4. An ORMOSIL-Containing Orthodontic Acrylic Resin with Concomitant Improvements in Antimicrobial and Fracture Toughness Properties

    Science.gov (United States)

    Rueggeberg, Frederick A.; Niu, Li-na; Mettenberg, Donald; Yiu, Cynthia K. Y.; Blizzard, John D.; Wu, Christine D.; Mao, Jing; Drisko, Connie L.; Pashley, David H.; Tay, Franklin R.

    2012-01-01

    Global increase in patients seeking orthodontic treatment creates a demand for the use of acrylic resins in removable appliances and retainers. Orthodontic removable appliance wearers have a higher risk of oral infections that are caused by the formation of bacterial and fungal biofilms on the appliance surface. Here, we present the synthetic route for an antibacterial and antifungal organically-modified silicate (ORMOSIL) that has multiple methacryloloxy functionalities attached to a siloxane backbone (quaternary ammonium methacryloxy silicate, or QAMS). By dissolving the water-insoluble, rubbery ORMOSIL in methyl methacrylate, QAMS may be copolymerized with polymethyl methacrylate, and covalently incorporated in the pressure-processed acrylic resin. The latter demonstrated a predominantly contact-killing effect on Streptococcus mutans ATCC 36558 and Actinomyces naselundii ATCC 12104 biofilms, while inhibiting adhesion of Candida albicans ATCC 90028 on the acrylic surface. Apart from its favorable antimicrobial activities, QAMS-containing acrylic resins exhibited decreased water wettability and improved toughness, without adversely affecting the flexural strength and modulus, water sorption and solubility, when compared with QAMS-free acrylic resin. The covalently bound, antimicrobial orthodontic acrylic resin with improved toughness represents advancement over other experimental antimicrobial acrylic resin formulations, in its potential to simultaneously prevent oral infections during appliance wear, and improve the fracture resistance of those appliances. PMID:22870322

  5. Preparation of Polyurethane Acrylate Coated Carbon Nanotube Nanocomposites by Emulsion Polymerization.

    Science.gov (United States)

    Talat, Jila; Sabzi, Mohammad; Safibonab, Behrouz; Hasanzadeh, Iraj; Arman, Ali; Karimzadeh, Isa

    2018-02-01

    The aim of this work was to prepare strong and conductive polyurethane acrylate nanocomposites. First, urethane prepolymers with different molecular weights and hydrophilicities were synthetized. Then, their corresponding polyurethane acrylate nanocomposites were prepared by ultrasonically-assisted emulsion polymerization in the presence of various ratios of urethane prepolymers and acrylate monomers. Thermogravimetric analysis (TGA) and tensile results showed that thermal stability and mechanical properties of polyurethane acrylate samples are significantly dependent on the molecular weight and hydrophilicity of the urethane prepolymer as well as the content of acrylate monomers. Polyurethane acrylate sample (i.e., PUAc-2B50) with optimum mechanical properties and thermal stability were chosen as matrix to prepare nanocomposites in the presence of nanotubes grafted with polymerizable acrylate groups (G-MWNTs). Transmission electron microscope (TEM) revealed that the surface of nanotubes is uniformly coated with polymer nanoparticles. The nanocomposites containing 3 wt% G-MWNTs demonstrated a great modulus up to 374 MPa and excellent strength up to 18.74 MPa. Meanwhile, they indicated remarkable high electrical and thermal conductivities; as the electrical conductivity of the nanocomposites increased by more than twelve orders of magnitude, and thermal conductivity reached to 12.5 times of the neat matrix. The developed nanocomposites hold high potential for diverse applications, such as printable electronic devices, nano-sensors, and heat/electrical induced shape memory polymers.

  6. Effect of thermal cycling and disinfection on microhardness of acrylic resin denture base.

    Science.gov (United States)

    Goiato, Marcelo Coelho; Dos Santos, Daniela Micheline; Baptista, Gabriella Trunckle; Moreno, Amália; Andreotti, Agda Marobo; Dekon, Stéfan Fiuza de Carvalho

    2013-04-01

    The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins.

  7. Polyurethane acrylate networks including cellulose nanocrystals: a comparison between UV and EB- curing

    Science.gov (United States)

    Furtak-Wrona, K.; Kozik-Ostrówka, P.; Jadwiszczak, K.; Maigret, J. E.; Aguié-Béghin, V.; Coqueret, X.

    2018-01-01

    A water-based polyurethane (PUR) acrylate water emulsion was selected as a radiation curable matrix for preparing nanocomposites including cellulose nanocrystals (CNC) prepared by controlled hydrolysis of Ramie fibers. Cross-linking polymerization of samples prepared in the form of films or of 1 mm-thick bars was either initiated by exposure to the 395 nm light of a high intensity LED lamp or by treatment with low energy electron beam (EB). The conversion level of acrylate functions in samples submitted to increasing radiation doses was monitored by Fourier Transform Infrared Spectroscopy (FTIR). Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) were used to characterize changes in the glass transition temperature of the PUR-CNC nanocomposites as a function of acrylate conversion and of CNC content. Micromechanical testing indicates the positive effect of 1 wt% CNC on Young's modulus and on the tensile strength at break (σ) of cured nanocomposites. The presence of CNC in the PUR acrylate matrix was shown to double the σ value of the nanocomposite cured to an acrylate conversion level of 85% by treatment with a 25 kGy dose under EB, whereas no increase of σ was observed in UV-cured samples exhibiting the same acrylate conversion level. The occurrence of grafting reactions inducing covalent linkages between the polysaccharide nanofiller and the PUR acrylate matrix during the EB treatment is advanced as an explanation to account for the improvement observed in samples cured under ionizing radiation.

  8. Gaseous carbon dioxide absorbing column

    International Nuclear Information System (INIS)

    Harashina, Heihachi.

    1994-01-01

    The absorbing column of the present invention comprises a cyclone to which CO 2 gas and Ca(OH) 2 are blown to form CaCO 3 , a water supply means connected to an upper portion of the cyclone for forming a thin water membrane on the inner wall thereof, and a water processing means connected to a lower portion of the cyclone for draining water incorporating CaCO 3 . If a mixed fluid of CO 2 gas and Ca(OH) 2 is blown in a state where a flowing water membrane is formed on the inner wall of the cyclone, formation of CaCO 3 is promoted also in the inside of the cyclone in addition to the formation of CaCO 3 in the course of blowing. Then, formed CaCO 3 is discharged from the lower portion of the cyclone together with downwardly flowing water. With such procedures, solid contents such as CaCO 3 separated at the inner circumferential wall are sent into the thin water membrane, adsorbed and captured, and the solid contents are successively washed out, so that a phenomenon that the solid contents deposit and grow on the inner wall of the cyclone can be prevented effectively. (T.M.)

  9. Column: Factors Affecting Data Decay

    Directory of Open Access Journals (Sweden)

    Kevin Fairbanks

    2012-06-01

    Full Text Available In nuclear physics, the phrase decay rate is used to denote the rate that atoms and other particles spontaneously decompose. Uranium-235 famously decays into a variety of daughter isotopes including Thorium and Neptunium, which themselves decay to others. Decay rates are widely observed and wildly different depending on many factors, both internal and external. U-235 has a half-life of 703,800,000 years, for example, while free neutrons have a half-life of 611 seconds and neutrons in an atomic nucleus are stable.We posit that data in computer systems also experiences some kind of statistical decay process and thus also has a discernible decay rate. Like atomic decay, data decay fluctuates wildly. But unlike atomic decay, data decay rates are the result of so many different interplaying processes that we currently do not understand them well enough to come up with quantifiable numbers. Nevertheless, we believe that it is useful to discuss some of the factors that impact the data decay rate, for these factors frequently determine whether useful data about a subject can be recovered by forensic investigation.(see PDF for full column

  10. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...

  11. The general packed column : an analytical solution

    NARCIS (Netherlands)

    Gielen, J.L.W.

    2000-01-01

    The transient behaviour of a packed column is considered. The column, uniformly packed on a macroscopic scale, is multi-structured on the microscopic level: the solid phase consists of particles, which may differ in incidence, shape or size, and other relevant physical properties. Transport in the

  12. Interaction Buckling Experiments of Box columns

    OpenAIRE

    永藤, 寿宮

    1988-01-01

    Box sections present very interesting properties in the field of compressed elements. The purpose of this experiment is to supply experimental data of interaction buckling (overall and local buckling). Test columns are classified into 4 types according to those columns length. Support conditions are pin-ended type by using new developed bowl shoe.

  13. Fringing-field effects in acceleration columns

    International Nuclear Information System (INIS)

    Yavor, M.I.; Weick, H.; Wollnik, H.

    1999-01-01

    Fringing-field effects in acceleration columns are investigated, based on the fringing-field integral method. Transfer matrices at the effective boundaries of the acceleration column are obtained, as well as the general transfer matrix of the region separating two homogeneous electrostatic fields with different field strengths. The accuracy of the fringing-field integral method is investigated

  14. Scintillation properties of acrylate based plastic scintillator by photoploymerization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hwan [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Lee, Joo Il [Dept. of of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima GoldTM LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380⁓520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400⁓ 800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

  15. Organoclay-epoxidized oil acrylate UV curable coatings

    International Nuclear Information System (INIS)

    Nantana Jiratumnukul; Patcharee Manowanna; Narangkhana Premmag

    2007-01-01

    Organoclay were prepared by cationic exchange process between Na + ions of montmorillonite in bentonite clay and two types of alkyl amines; hexadecylamine (primary amine) and hexadecyl trimethyl amine (tertiary amine). From XRD results showed that primary amine-modified bentonite clay provided greater inter-layer spacing than tertiary amine-modified bentonite clay. Modified clay with intercalation structure was incorporated into UV curable coating formulation using epoxidized linseed oil acrylate as an oligomer. Energy consumption in curing process and physical properties of cured films were studied as a function of the amount of modified clay incorporated in coating formulations. It was found that the energy consumption in curing process increased. In addition, hardness and flexibility of cured films also improved. (Author)

  16. Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses

    Directory of Open Access Journals (Sweden)

    Yunhai Dai

    2014-01-01

    Full Text Available Two three-piece hydrophobic acrylic intraocular lenses (IOLs were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to their opacified IOLs. In addition to light microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, confocal laser scanning microscopy was used for the first time to observe the explanted IOLs. The clinical aspect seemed to correspond to the phenomenon of surface light scattering, while laboratory analyses showed dense glistenings in the central layer of the IOL optic, which had no change next to the surface. Further studies on these phenomena are needed.

  17. Eco-friendly Crosslinking Agent for Acid Functional Acrylic Resin

    Directory of Open Access Journals (Sweden)

    Archana Shah

    2009-01-01

    Full Text Available Oil from J. multifida was extracted and it was first converted into N,N-bis(2-hydroxyethyl Jatropha fatty amide (HEJFA. HEJFA has been synthesized by reaction between Jatropha oil and diethanol amine in presence of zinc oxide as a catalyst. The reaction is relatively rapid and proceeded to high yield at 200±5 OC. The resulting HEJFA was used to formulate thermosetting coating compositions. Films were cured at ambient (air drying and elevated (stove drying temperatures using N, N-bis(2-hydroxyethyl Jatropha fatty amide (HEJFA as eco-friendly crosslinking agent for acrylic resin. The coating performance of the various compositions was tested by measurement of scratch hardness, impact strength and chemical resistance. The results show better performance of the HEJFA based compositions compared to butylated melamine formaldehyde (MF based compositions.

  18. Radiation curable coatings from palm oil acrylated polyester prepolymer

    International Nuclear Information System (INIS)

    Azam Ali, M.; Ooi, T.L.; Salmiah, A.; Ishiaku, U.S.; Mohd Ishak, Z.A.

    2002-01-01

    Radiation (ultra-violet, UV) curable coatings were prepared by using palm oil acrylated polyester prepolymer (PEPP-1) in combination with different reactive diluents in the presence of photoinitiator Irgacure 184 (Irg184). The effects of viscosity of coating materials, radiation dose and curing behavior were investigated. The UV cured polymeric films properties such as pendulum hardness, wettability (contact angle), gel ,content, swelling character, tensile strength, elongation at break, and deformation stability were then determined. The optimum formulations were also coated on wood substrates after which the gloss and hardness of the cured film on the wood substrate were measured. Some formulations showed promising coatings properties and has a good potential application for the wood coating industry. (Author)

  19. Crosslinkers of Different Types in Precipitation Polymerization of Acrylic Acid

    Directory of Open Access Journals (Sweden)

    H. Eshaghi

    2013-01-01

    Full Text Available Crosslinked poly(acrylic acids were prepared using two types of crosslinker by precipitation polymerization method in a binary organic solvent. N,N’-methylenebisacrylamide (MBA and polyethylene glycol dimethacrylate (PEGDMA-330 were used as low-molecular weight and long-chain crosslinkers, respectively. The effect of various types of crosslinkers on polymer characteristics (i.e., gel content, equilibrium swelling, glass transition temperature, and rheological properties was investigated. Maximum amount of viscosity was obtained by using long-chain crosslinker. The Flory-Rehner equation and rubber elasticity theory were used to discuss the network structure of polymer. It was observed that, the glass transition temperature (Tg of the synthesized polymer containing PEGDMA-330 is higher than that of polymer containing MBA. Apparent and rotational viscosity were used to determine the optimal crosslinker type. In addition, the consistencycoefficient (m and flow behavior index (n parameter of Ostwald equation were investigated as well.

  20. Water absorbency of chitosan grafted acrylic acid hydrogels

    Science.gov (United States)

    Astrini, N.; Anah, L.; Haryono, A.

    2017-07-01

    Acrylic acid (AA) monomer was directly grafted onto chitosan (CTS) using potassium persulfate (KPS) as an initiator and methylenebisacrylamide (MBA) as a crosslinking agent under an inert atmosphere. One factor affecting the swelling capacity of the obtained hydrogel, KPS concentration, were studied. The hydrogel products were characterized using Fourier Transform Infrared spectroscopy (FTIR) for chemical structure and scanning electron microscopy (SEM) for morphology. Swelling of the hydrogel samples in distilled water and saline solution ( 9% NaCl ) was examined. Swelling capacity of the CTS-g-PAA hydrogels in distilled water (88.53 g/g) was higher than in NaCl solution (29.94 g/g) The highest swelling capacity value was obtained when the grafted reaction was carried out using 2.5wt% initiator

  1. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials

    Science.gov (United States)

    Heidari, Bijan; Firouz, Farnaz; Izadi, Alireza; Ahmadvand, Shahbaz

    2015-01-01

    Objectives: Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a common clinical occurrence, which often develops in the midline of the denture base. This study aimed to evaluate the efficacy of cold-cure and heat-cure acrylic resins, reinforced with glass fibers, polyethylene fibers, and metal wire for denture base repair. Materials and Methods: Ninety specimens were prepared and allocated to nine groups. Ten specimens were considered as controls, and 80 were divided into 8 experimental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was divided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were subjected to a 3-point bending test, and the flexural strength was calculated. Results: The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement. Conclusion: Repairing denture base with heat cure acrylic resin, reinforced with glass fibers increases the flexural strength of denture base. PMID:26877726

  2. Flexural Strength of Cold and Heat Cure Acrylic Resins Reinforced with Different Materials

    Directory of Open Access Journals (Sweden)

    Bijan Heidari

    2015-10-01

    Full Text Available Objectives: Heat-polymerized acrylic resin has been the most commonly used denture base material for over 60 years. However, the mechanical strength of acrylic resin is not adequate for long-term clinical performance of dentures. Consequently, fracture is a com- mon clinical occurrence, which often occurs in the midline of denture base.This study aimed to evaluate the efficacy of cold cure and heat cure acrylic resins, rein- forced with glass fibers, polyethylene fibers, and metal wire for denture base repair.Materials and Methods: Ninety specimens were prepared and allocated to nine groups. Ten specimens were included in the control group, and 80 were allocated to 8 experi- mental groups. In the experimental groups, the specimens were sectioned into two halves from the middle, and were then divided into two main groups: one group was repaired with heat cure acrylic resin, and the other with cold cure acrylic resin. Each group was di- vided into 4 subgroups: unreinforced, reinforced with glass fibers, polyethylene fibers, and metal wire. All specimens were then subjected to a 3-point bending test, and the flexural strength was calculated.Results: The group repaired with heat cure acrylic resin and reinforced with glass fiber showed the highest flexural strength; however, the group repaired with cold cure acrylic resin and reinforced with polyethylene fibers had the lowest flexural strength. There was no significant difference between the groups repaired with heat cure and cold cure acrylic resins without reinforcement.Conclusion: Repairing denture base with heat cure acrylic resin, reinforced with glass fi- bers increases the flexural strength of denture base.

  3. Optimization of cellulose acrylate and grafted 4-vinylpyridine and 1-vinylimidazole synthesis

    Directory of Open Access Journals (Sweden)

    Bojanić Vaso

    2010-01-01

    Full Text Available Optimization of cellulose acrylate synthesis by reaction with sodium cellulosate and acryloyl chloride was carried out. Optimal conditions for conducting the synthesis reaction of cellulose acrylate were as follows: the molar ratio of cellulose/potassium-t-butoxide/acryloyl chloride was 1:3:10 and the optimal reaction time was 10 h. On the basis of elemental analysis with optimal conditions for conducting the reaction of cellulose acrylate, the percentage of substitution of glucose units in cellulose Y = 80.7%, and the degree of substitution of cellulose acrylate DS = 2.4 was determined. The grafting reaction of acrylate vinyl monomers onto cellulose in acetonitrile with initiator azoisobutyronitrile (AIBN in a nitrogen atmosphere was performed, by mixing for 5 h at acetonitrile boiling temperature. Radical copolymerization of synthesized cellulose acrylate and 4-vinylpyridine, 1-vinylimidazole, 1-vinyl-2-pyrrolidinone and 9-vinylcarbazole, cellulose-poly-4-vinylpyridine (Cell-PVP, cellulose-poly-1- vinylimidazole (Cell-PVIm and cellulose-poly-1-vinyl-2-pyrrolidinone (Cell-P1V2P and cellulose-poly-9-vinylcarbazole (Cell-P9VK were synthesized. Acrylate cellulose and cellulose grafted copolymers were confirmed by IR spectroscopy, based on elementary analysis and the characteristics of grafted copolymers of cellulose were determined. The mass share of grafted copolymers, X, the relationship of derivative parts/cellulose vinyl group, Z, and the degree of grafting copolymers of cellulose (mass% were determined. In reaction of methyl iodide and cellulose-poly-4-vinylpyridine (Cell-PVP the cellulose-1-methyl-poly-4-vinylpyridine iodide (Cell-1-Me-PVPJ was synthesized. Cellulose acrylate and grafted copolymers were obtained with better thermal, electrochemical and ion-emulation properties for bonding of noble metals Au, Pt, Pd from water solutions. The synthesis optimization of cellulose acrylate was applied as a model for the synthesis of grafted

  4. MLEP-Fail calibration for 1/8 inch thick cast plate of 17-4 steel.

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    The purpose of the work presented in this memo was to calibrate the Sierra material model Multilinear Elastic-Plastic Hardening Model with Failure (MLEP-Fail) for 1/8 inch thick cast plate of 17-4 steel. The calibration approach is essentially the same as that recently used in a previous memo using data from smooth and notched tensile specimens. The notched specimens were manufactured with three notch radii R = 1=8, 1/32 and 1/64 inches. The dimensions of the smooth and notched specimens are given in the prints in Appendix A. Two cast plates, Plate 3 and Plate 4, with nominally identical properties were considered.

  5. [The biomechanical behaviour of the flexible acrylic partial prosthetics].

    Science.gov (United States)

    Gheban, E; Forna, Norina Consuela

    2008-01-01

    The simulation methods constitute a modern method absolutely necessary at the forerunner stage of the practical unwinding of the research stages, outlining the precise directions for the practical application, the final results influencing the dental practice. Our study proposes itself to analyze through the method of the finite element the status of the tension and the deformations registered at the level of the partially extended indentured prosthetic field and at the level of the partially flexible acrylic prosthetics. The first step was constituted by the realization of CT followed by their scanning and the usage of the material constants. Following the tomographic computer exam at the patients submitted to the study, it was observed a resorption and an important atrophy at the level of the jaw indented crest, after a period of four months, with the flexible prosthetics type Valplast, this aspect having profound clinical and viability implications to the selected therapy solution. For the 3D reconstruction of the different types of partial extended indentation the Amira universal program was used for the 3D reconstructions for any type of Tomographic Computer. Following the 3D reconstructions of the information obtained on the tomographic computer on the images it can be observed an important resorption of the jaw bone in the area of the edentulous space with an acrylic flexible prosthetics. The intrusion of the silicon material Rubber type, as a viable solution for the reduction of the absorption rate and atrophy of the partially indented prosthetics field, has results proportional to the type of the force applied and the applying of this. The simulation of the real clinical situations following the contribution of the tomographic computer constitutes a highly important stage in the evaluation of the degree of resorption and atrophy at the level of the indented crests, process whose parameters are influenced by the factorial accumulation with a profound impact

  6. Flexural strength of acrylic resins polymerized by different cycles

    Directory of Open Access Journals (Sweden)

    Débora Barros Barbosa

    2007-10-01

    Full Text Available Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Clássico, a microwave-polymerized (Onda-Cryl and a autopolymerizing acrylic (Jet resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 sec, and manufacturing microwave cycle - 320W/3 min + 0W/3 min + 720W/3 min; T (Clássico, water bath cycle - 74ºC/9h and Q (Jet, press chamber cycle - 50ºC/15 min at 2 bar. Ten specimens (65 x 10 x 3.3mm were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5% level. The microwave-polymerized groups showed the highest means (p<0.05 for flexural strength (MPa (A = 106.97 ± 5.31; B = 107.57 ± 3.99; C = 109.63 ± 5.19, and there were no significant differences among them. The heat-polymerized group (T showed the lowest flexural strength means (84.40 ± 1.68, and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.

  7. Center column design of the PLT

    International Nuclear Information System (INIS)

    Citrolo, J.; Frankenberg, J.

    1975-01-01

    The center column of the PLT machine is a secondary support member for the toroidal field coils. Its purpose is to decrease the bending moment at the nose of the coils. The center column design was to have been a stainless steel casting with the toroidal field coils grouped around the casting at installation, trapping it in place. However, the castings developed cracks during fabrication and were unsuitable for use. Installation of the coils proceeded without the center column. It then became necessary to redesign a center column which would be capable of installation with the toroidal field coils in place. The final design consists of three A-286 forgings. This paper discusses the final center column design and the influence that new knowledge, obtained during the power tests, had on the new design

  8. Repair of bis-acryl provisional restorations using flowable composite resin.

    Science.gov (United States)

    Bohnenkamp, David M; Garcia, Lily T

    2004-11-01

    Provisional restorations provide interim coverage for prepared teeth while fixed definitive restorations are fabricated. Several types of autopolymerizing acrylic resins have been used for many years to fabricate provisional restorations. In recent years, bis-acryl resin composite material has gained popularity among clinicians for the direct fabrication of provisional fixed restorations. Occasionally, deficiencies may occur while fabricating a direct provisional restoration and require chairside repair. This article describes an effective procedure for the use of light-polymerized flowable composite resin for the intraoral repair of bis-acryl provisional restorations.

  9. Durability and Mechanical Performance of PMMA/Stone Sludge Nanocomposites for Acrylic Solid Surface Applications

    Directory of Open Access Journals (Sweden)

    Samah EL-Bashir

    2017-11-01

    Full Text Available Acrylic solid surface sheets were prepared by mixing different kinds of stone sludge fillers (SSF in Poly (methyl methacrylate (PMMA nanocomposites. PMMA nanocomposite syrups were made using free radical polymerization of methylmethacrylate (MMA, then two kinds of nanofillers were added, namely, hydrophilic nanosilica and clay Halloysite nanotubules (HNTs. Acrylic solid surface sheets were manufactured by mixing the syrups with SSFs. The morphology of the produced sheets was studied using optical, and Scanning Electron Microscopy (SEM that revealed the uniform distribution of stone sludge in the polymeric matrix. The study of the physical properties showed promising mechanical performance and durability of PMMA/SSF nanocomposites for acrylic solid surface applications.

  10. Studies on the Influence of Monomers on the Performance Properties of Epoxy Acrylate Resin

    Directory of Open Access Journals (Sweden)

    Amrita Sharma

    2008-01-01

    Full Text Available Twelve blend samples were prepared by physical mixing of epoxy acrylate resins with various monomers viz. ethoxylated phenol monoacrylate (EOPA, tripropylene glycol diacrylate (TPGDA and trimethylol propane tri acrylate(TMPTA, having weight ratio of epoxy acrylate resin and monomers are 50:50, 60:40, 70:30, 80:20. These samples were cured under UV radiation using 5% photo initiator by weight. These blends were evaluated for mechanical, chemical & thermal properties. It was found that the sample having mono & tri functional monomers shows better properties than the samples having di functional monomer.

  11. Admittance Scanning for Whole Column Detection.

    Science.gov (United States)

    Stamos, Brian N; Dasgupta, Purnendu K; Ohira, Shin-Ichi

    2017-07-05

    Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 μm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 μm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 μm i.d. column) of 500 μM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

  12. Optimizing Facility Configurations and Operating Conditions for Improved Performance in the NASA Ames 24 Inch Shock Tube

    Science.gov (United States)

    Bogdanoff, David W.; Cruden, Brett A.

    2016-01-01

    The Ames Electric Arc Shock Tube (EAST) is a shock tube wherein the driver gas can be heated by an electric arc discharge. The electrical energy is stored in a 1.2 MJ capacitor bank. Four inch and 24 inch diameter driven tubes are available. The facility is described and the need for testing in the 24 inch tube to better simulate low density NASA mission profiles is discussed. Three test entries, 53, 53B and 59, are discussed. Tests are done with air or Mars gas (95.7% CO2/2.7% N2/1.6% Ar) at pressures of 0.01 to 0.14 Torr. Velocities spanned 6.3-9.2 km/s, with a nominal center of 7 km/s. Many facility configurations are studied in an effort to improve data quality. Various driver and driven tube configurations and the use of a buffer section between the driver and the driven tube are studied. Diagnostics include test times, time histories of the shock light pulses and tilts of the shock wave off the plane normal to the tube axis. The report will detail the results of the various trials, give the best configuration/operating conditions found to date and provide recommendations for further improvements. Finally, diaphragm performance is discussed.

  13. Synthesis and characterization of poly(2-ethylhexyl acrylate ...

    Indian Academy of Sciences (India)

    polymerization results of PEHA prepared via ATRP,. RATRP and FRP in bulk and in solution. 2. Experimental. 2.1 Materials. 2-Ethylhexylacrylate (EHA) (98%, BASF) and methyl methacrylate (MMA) (99%, Aldrich) were used after removing inhibitor by passing through alu- mina (basic) packed column. CuBr (98%, Aldrich),.

  14. Field Applications of Gamma Column Scanning Technology

    International Nuclear Information System (INIS)

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  15. Collapse of tall granular columns in fluid

    Directory of Open Access Journals (Sweden)

    Kumar Krishna

    2017-01-01

    Full Text Available Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  16. Collapse of tall granular columns in fluid

    Science.gov (United States)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  17. Effect of silver nanoparticles incorporation on viscoelastic properties of acrylic resin denture base material.

    Science.gov (United States)

    Mahross, Hamada Zaki; Baroudi, Kusai

    2015-01-01

    The objective was to investigate the effect of silver nanoparticles (AgNPs) incorporation on viscoelastic properties of acrylic resin denture base material. A total of 20 specimens (60 × 10 × 2 mm) of heat cured acrylic resin were constructed and divided into four groups (five for each), according to the concentration of AgNPs (1%, 2%, and 5% vol.) which incorporated into the liquid of acrylic resin material and one group without additives (control group). The dynamic viscoelastic test for the test specimens was performed using the computerized material testing system. The resulting deflection curves were analyzed by material testing software NEXYGEN MT. The 5% nanoparticles of silver (NAg) had significantly highest mean storage modulus E' and loss tangent Tan δ values followed by 2% NAg (P 0.05). The AgNPs incorporation within the acrylic denture base material can improve its viscoelastic properties.

  18. Modeling the environmental fate of perfluoroctanoate and its precursors from global fluorotelomer acrylate polymer use.

    NARCIS (Netherlands)

    van Zelm, R.; Huijbregts, M.A.J.; Russell, M.H.; Jager, T.; van de Meent, D.

    2008-01-01

    The environment contains various direct and indirect sources of perfluorooctanoic acid (PFOA). The present study uses a dynamic multispecies environmental fate model to analyze the potential formation of perfluorooctanoate (PFO), the anion of PFOA, in the environment from fluorotelomer acrylate

  19. Preparation and characterization of emulsifier-free polyphenylsilsesquioxane-poly (styrene–butyl acrylate) hybrid particles

    International Nuclear Information System (INIS)

    Bai, Ruiqin; Qiu, Teng; Han, Feng; He, Lifan; Li, Xiaoyu

    2013-01-01

    The core–shell polyphenylsilsesquioxane-poly (styrene–butyl acrylate) hybrid latex paticles with polyphenylsilsesquioxane as core and poly (styrene–butyl acrylate) as shell were successfully synthesized by seeded emulsion polymerization using polyphenylsisesquioxane (PPSQ) latex particles as seeds. X-ray diffraction (XRD) indicated that the polyphenylsilsesquioxane (PPSQ) had ladder structure, and PPSQ had incorporated into the hybrid latex particles. Transmission electron microscopy (TEM) confirmed that the resultant hybrid latex particles had the core–shell structure. TEM and dynamic light scattering (DLS) analysis indicated that the polyphenylsisesquioxane latex particles and obtained core–shell hybrid latex particles were uniform and possessed narrow size distributions. X-ray photoelectron spectroscopy (XPS) analysis also indicated that the PPSQ core particles were enwrapped by the polymer shell. In addition, compared with pure poly (styrene–butyl acrylate) latex film, the polyphenylsilsesquioxane-poly (styrene–butyl acrylate) hybrid latex film exhibited lower water uptake, higher pencil hardness and better thermal stability.

  20. Extraction of metal cations by polyterephthalamide microcapsules containing a poly(acrylic acid) gel.

    Science.gov (United States)

    Laguecir, A; Ernst, B; Frère, Y; Danicher, L; Burgard, M

    2002-01-01

    Polyterephthalamide microcapsules containing a poly(acrylic acid) gel as a macromolecular ligand (PAA-CAPS) were prepared using an original two step polymerization process in a water-in-oil inverse emulsion system. A polyamide microcapsule containing acrylic acid, initiator and cross-linking agent, is formed by interfacial polycondensation of terephthaloyl dichloride with hexamethylenediamine. In situ radical polymerization of the microcapsule core acrylic acid is initiated to obtain encapsulated poly(acrylic acid) gel. Reference polyamide microcapsules, i.e. without ligand (CAPS), were also synthesized. The mean diameter of synthesized microcapsules was 210 microm, and the microcapsule wall thickness was evaluated by SEM and TEM observations of microcapsule cross-section cuts. The microcapsule water content was determined by thermogravimetric experiments. The extractabilities of Cu(II), Ni(II), Co(II) and Zn(II) into PAA-CAPS were examined. The stripping of the various cations can be promoted in diluted hydrochloric acid solutions.

  1. Synthesis and behavior of silyl group-containing acrylic resins as weather resistant coatings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, I.M. [Myongji University, Yongin (Korea); Kim, S.K. [Sam-Hwa Paints Ind. Co. Ltd., Ansan (Korea); Wu, J.P.; Kim, M.S.; Park, H.S. [Myongji University, Yongin (Korea)

    2001-05-01

    Silyl group-containing acrylic resins were synthesized to prepare weather resistant coatings. Acrylic copolymer was synthesized by the addition copolymerization of n-butyl acrylate and 3-methacryloxypropyl trimethoxysilane (MPTS). Acrylic copolymer were synthesized such that their T{sub g}'s were adjusted to 20 deg. C and their MPTS contents were varied to 10, 20 and 30 wt%. As the content of MPTS increase, viscosity of coatings increased and thermal stability at the high temperature was improved. Coatings was prepared by blending the synthesized resins with a white pigment. The adhesion performance of coatings was superior with various substrates and their other properties were on the whole suitable. Weather ability was tested by outdoor exposure test, WOM test and QU test. It was proved that resin with 30 wt% MPTS was suitable as the binder for weather resistant coatings. (author). 14 refs., 7 tabs., 11 figs.

  2. Do flexible acrylic resin lingual flanges improve retention of mandibular complete dentures?

    Science.gov (United States)

    Ahmed Elmorsy, Ayman Elmorsy; Ahmed Ibraheem, Eman Mostafa; Ela, Alaa Aboul; Fahmy, Ahmed; Nassani, Mohammad Zakaria

    2015-01-01

    The aim of this study was to compare the retention of conventional mandibular complete dentures with that of mandibular complete dentures having lingual flanges constructed with flexible acrylic resin "Versacryl." The study sample comprised 10 completely edentulous patients. Each patient received one maxillary complete denture and two mandibular complete dentures. One mandibular denture was made of conventional heat-cured acrylic resin and the other had its lingual flanges made of flexible acrylic resin Versacryl. Digital force-meter was used to measure retention of mandibular dentures at delivery and at 2 weeks and 45 days following denture insertion. The statistical analysis showed that at baseline and follow-up appointments, retention of mandibular complete dentures with flexible lingual flanges was significantly greater than retention of conventional mandibular dentures (P dentures, retention of dentures increased significantly over the follow-up period (P acrylic resin lingual flanges in the construction of mandibular complete dentures improved denture retention.

  3. Effects of water on starch-g-polystyrene and starch-g-poly(methyl acrylate) extrudates

    International Nuclear Information System (INIS)

    Henderson, A.M.; Rudin, A.

    1982-01-01

    Polystyrene and poly(methyl acrylate) were grafted onto wheat starch by gamma radiation and chemical initiation, respectively. The respective percent add-on values were 46 and 45; 68% of the polystyrene formed was grafted to starch, and corresponding proportion of poly(methyl acrylate) was 41%. The molecular weight distributions of the homopolymer and graft portions were characterized, and extrusion conditions were established for production of ribbon samples of starch-g-PS and starch-g-PMA. Both copolymer types were considerably weakened by soaking in water, and this effect was more immediate and drastic for starch-g-poly(methyl acrylate). Both graft copolymers regained their original tensile strengths on drying, but the poly(methyl acrylate) specimens did not recover their original unswollen dimensions and retained high breaking elongations characteristic of soaked specimens. Tensile and dynamic mechanical properties of extruded and molded samples of both graft polymers are reported, and plasticizing effects of water are summarized

  4. Emulsion polymerization of polystyrene-co-acrylic acid with Cu2O incorporation

    Science.gov (United States)

    Fahmiati, Sri; Harmami, Sri Budi; Meliana, Yenny; Haryono, Agus

    2017-01-01

    In this research, poly(styrene-co-acrylic acid-Cu) was prepared via emulsion polymerization.Cu contents were varied as 10%, 15% and 20% and mol ratio of styrene to acrylic acid as 1:1 and 2:1. Structure and surface of poly(styrene-co-acrylic acid-Cu) were characterized by FTIR (Fourier Transformed Infra Red), NMR (Nuclear Magnetic Resonance), and SEM/EDX (Scanning Electron Microcope/ Energy Dispersive X-Ray) spectroscopy. The NMR spectra showed that the polymer was formed, however FTIR spectra showed that there were still unreacted monomers. SEM-EDX confirmed that copper (Cu) was dispersed uniformly on poly(styrene-co-acrylic acid-Cu) matrix.

  5. Synthesis and characterization of amylose grafted poly(acrylic acid) and its application in ammonia adsorption.

    Science.gov (United States)

    Chen, Qing; Yu, Haojie; Wang, Li; Abdin, Zain-Ul; Yang, Xinpeng; Wang, Junhua; Zhou, Weidong; Zhang, Hongtao; Chen, Xiao

    2016-11-20

    Amylose grafted poly(acrylic acid) (Am-g-PAA) was synthesized by graft copolymerization of amylose with acrylic acid. The structure of Am-g-PAA was confirmed by (1)H NMR and FT-IR spectra. The morphology, crystallinity and thermal properties of amylose and Am-g-PAA were investigated by SEM, XRD and TGA, respectively. The highest degree of substitution (DS) of carboxyl group was 1.96 which was obtained after reacted for 1h at 60°C. Acrylic acid to anhydroglucose mole ratio for DS was 19.81. It was found that a large number of carboxyl groups were grafted on the backbone of amylose. It was also found that ammonia adsorption capacity of amylose increased by grafting poly(acrylic acid) on the backbone of amylose. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Carbon fiber reinforced thermoplastic composites from acrylic polymer matrices: Interfacial adhesion and physical properties

    Directory of Open Access Journals (Sweden)

    H. Kishi

    2017-04-01

    Full Text Available Acrylic polymers have high potential as matrix polymers for carbon fiber reinforced thermoplastic polymers (CFRTP due to their superior mechanical properties and the fact that they can be fabricated at relatively low temperatures. We focused on improving the interfacial adhesion between carbon fibers (CFs and acrylic polymers using several functional monomers for co-polymerization with methyl methacrylate (MMA. The copolymerized acrylic matrices showed good adhesion to the CF surfaces. In particular, an acrylic copolymer with acrylamide (AAm showed high interfacial adhesive strength with CFs compared to pure PMMA, and a hydroxyethyl acrylamide (HEAA copolymer containing both amide and hydroxyl groups showed high flexural strength of the CFRTP. A 3 mol% HEAA-copolymerized CFRTP achieved a flexural strength almost twice that of pure PMMA matrix CFRTP, and equivalent to that of an epoxy matrix CFRP.

  7. Effect of microwave cured acrylic resin on candidal growth in complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on candidal growth . Seven completely edentulous male patients with on history of denture wearing participated in this study. all the selected patients were re-habilitated by mucosa supported complete dentures .The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. one month resting period was allowed so as candidal count can reach to normal, then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique.

  8. Dynamic effects of diabatization in distillation columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    The dynamic effects of diabatization in distillation columns are investigated in simulation emphasizing the heat-integrated distillation column (HIDiC). A generic, dynamic, first-principle model has been formulated, which is flexible enough to describe various diabatic distillation configurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found and control...

  9. Dynamic Effects of Diabatization in Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2012-01-01

    The dynamic eects of diabatization in distillation columns are investigated in simulation with primary focus on the heat-integrated distillation column (HIDiC). A generic, dynamic, rst-principle model has been formulated, which is exible to describe various diabatic distillation congurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found. Control...

  10. Allergic contact dermatitis caused by nail acrylates in Europe. An EECDRG study

    DEFF Research Database (Denmark)

    Gonçalo, Margarida; Pinho, André; Agner, Tove

    2018-01-01

    BACKGROUND: Allergic contact dermatitis (ACD) caused by nail acrylates, also including methacrylates and cyanoacrylates here, is being increasingly reported. METHODS: A retrospective study in 11 European Environmental Contact Dermatitis Research Group (EECDRG) clinics collected information on cases......-hydroxypropyl methacrylate (88.6%), ethylene glycol dimethacrylate (69.2%), and ethyl cyanoacrylate (9.9%). CONCLUSIONS: Nail cosmetics were responsible for the majority of ACD cases caused by acrylates, affecting nail beauticians and consumers, and therefore calling for stricter regulation and preventive...

  11. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

    OpenAIRE

    Nam, Ki-Young

    2014-01-01

    PURPOSE This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transm...

  12. In vitro cytotoxicity of self-curing acrylic resins of different colors

    Directory of Open Access Journals (Sweden)

    Luciana Borges Retamoso

    2014-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess the in vitro cytotoxicity of acrylic resins of different colors over time. METHODS: Specimens were divided into 4 groups (n = 6 according to the color of the acrylic resin (Orto Class, Clássico, Campinas, São Paulo, Brazil: Group 1: clear acrylic resin; group 2: pink acrylic resin; group 3: blue acrylic resin and group 4: green acrylic resin. All specimens were fabricated according to the mass manipulation technique and submitted to mechanical polishing protocol. The control was performed with an amalgam specimen (C+, a glass specimen (C- and cell control (CC. Specimens were immersed in Minimum Eagle's Medium (MEM and incubated for 24 h at 37o C. The extracts from the experimental material were filtered and mixed with L929 fibroblast. Cytotoxicity was evaluated at 4 different times, 24, 48, 72 and 168 h. After contact, cells were incubated for 24 h and added to 100 µ of 0.01% neutral red dye. The cells were incubated for 3 h for pigment incorporation and fixed. Cells viability was determined by a spectroscopic (BioTek, Winooski, Vermont, USA with a 492-nm wavelength λ=492 nm. RESULTS: There were no statistical differences between the experimental groups and the CC and C- groups. CONCLUSION: Clear, pink, blue and green self-curing acrylic resins fabricated by means of the mass manipulation technique and mechanically polished are not cytotoxic. Neither the pigment added to the self-curing acrylic resin nor the factor of time influenced the cytotoxicity of the material.

  13. Do flexible acrylic resin lingual flanges improve retention of mandibular complete dentures?

    OpenAIRE

    Ahmed Elmorsy, Ayman Elmorsy; Ahmed Ibraheem, Eman Mostafa; Ela, Alaa Aboul; Fahmy, Ahmed; Nassani, Mohammad Zakaria

    2015-01-01

    Objectives: The aim of this study was to compare the retention of conventional mandibular complete dentures with that of mandibular complete dentures having lingual flanges constructed with flexible acrylic resin ?Versacryl.? Materials and Methods: The study sample comprised 10 completely edentulous patients. Each patient received one maxillary complete denture and two mandibular complete dentures. One mandibular denture was made of conventional heat-cured acrylic resin and the other had its ...

  14. Evaluation of methods for stain removal in acrylic resin denture teeth: in vitro study

    OpenAIRE

    CASSIANO,Ana Flávia Balestrero; LEITE,Andressa Rosa Perin; POLICASTRO,Vivian Barnabé; COMPAGNONI,Marco Antonio; PERO,Ana Carolina

    2016-01-01

    Abstract Introduction The staining of artificial teeth can be related to the acrylic resin abrasion caused by brushing, resulting in higher deposition of dyes from the beverage, and consequently higher aesthetic damage. Objective The aim of this in vitro study was to evaluate methods for removal of stains from acrylic denture teeth using spectrophotometric analysis. Material and method Artificial teeth were divided into twelve groups (n=10) according to the type of treatment (re-polishing ...

  15. Evaluation of thermal conductivity of heat-cured acrylic resin mixed with A1203

    OpenAIRE

    Ebadian B.; Parkan MA.

    2002-01-01

    One of the most important characteristics of denture base is thermal conductivity. This property has a major role in secretions of salivary glands and their enzymes, taste of the food and gustatory response. Polymethyl methacrylate used in prosthodontics is relatively an insulator. Different materials such as metal fillers and ceramics have been used to solve this problem. The aim of this study was the evaluation of AI2O3 effect on thermal conductivity of heat-cured acrylic resin. Acrylic res...

  16. Preparation of a Novel Water-based Acrylic Multi-Thermal Insulation Coating

    OpenAIRE

    Xiufang YE; Dongchu CHEN; Menglei CHANG; Youtian MO; Qingxiang WANG

    2017-01-01

    To efficiently improve the thermal insulation effect of coatings, a novel water-based acrylic multi-thermal insulation coating (multi-WATIC) combined with thermal obstruction, echo, and radiation was prepared. The category and ratio of thermal insulation functional fillers are crucial. First, water-based acrylic thermal insulation coating (WATIC) with single thermal insulation functional fillers was prepared, and the thermal insulation property tests were done. Thereafter, a novel multi-WATIC...

  17. Silane-Acrylate Chemistry for Regulating Network Formation in Radical Photopolymerization.

    Science.gov (United States)

    Steindl, Johannes; Koch, Thomas; Moszner, Norbert; Gorsche, Christian

    2017-10-10

    Photoinitiated silane-ene chemistry has the potential to pave the way toward spatially resolved organosilicon compounds, which might find application in biomedicine, microelectronics, and other advanced fields. Moreover, this approach could serve as a viable alternative to the popular photoinitiated thiol-ene chemistry, which gives access to defined and functional photopolymer networks. A difunctional bis(trimethylsilyl)silane with abstractable hydrogens (DSiH) was successfully synthesized in a simple one-pot procedure. The radical reactivity of DSiH with various homopolymerizable monomers (i.e., (meth)acrylate, vinyl ester, acrylamide) was assessed via 1 H NMR spectroscopic studies. DSiH shows good reactivity with acrylates and vinyl esters. The most promising silane-acrylate system was further investigated in cross-linking formulations toward its reactivity (e.g., heat of polymerization, curing time, occurrence of gelation, double-bond conversion) and compared to state-of-the-art thiol-acrylate resins. The storage stability of prepared resin formulations is greatly improved for silane-acrylate systems vs thiol-ene resins. Double-bond conversion at the gel point (DBC gel ) and overall DBC were increased, and polymerization-induced shrinkage stress has been significantly reduced with the introduction of silane-acrylate chemistry. Resulting photopolymer networks exhibit a homogeneous network architecture (indicated by a narrow glass transition) that can be tuned by varying silane concentration, and this confirms the postulated regulation of radical network formation. Similar to thiol-acrylate networks, this leads to more flexible photopolymer networks with increased elongation at break and improved impact resistance. Additionally, swelling tests indicate a high gel fraction for silane-acrylate photopolymers.

  18. Silane–Acrylate Chemistry for Regulating Network Formation in Radical Photopolymerization

    Science.gov (United States)

    2017-01-01

    Photoinitiated silane–ene chemistry has the potential to pave the way toward spatially resolved organosilicon compounds, which might find application in biomedicine, microelectronics, and other advanced fields. Moreover, this approach could serve as a viable alternative to the popular photoinitiated thiol–ene chemistry, which gives access to defined and functional photopolymer networks. A difunctional bis(trimethylsilyl)silane with abstractable hydrogens (DSiH) was successfully synthesized in a simple one-pot procedure. The radical reactivity of DSiH with various homopolymerizable monomers (i.e., (meth)acrylate, vinyl ester, acrylamide) was assessed via 1H NMR spectroscopic studies. DSiH shows good reactivity with acrylates and vinyl esters. The most promising silane–acrylate system was further investigated in cross-linking formulations toward its reactivity (e.g., heat of polymerization, curing time, occurrence of gelation, double-bond conversion) and compared to state-of-the-art thiol–acrylate resins. The storage stability of prepared resin formulations is greatly improved for silane–acrylate systems vs thiol–ene resins. Double-bond conversion at the gel point (DBCgel) and overall DBC were increased, and polymerization-induced shrinkage stress has been significantly reduced with the introduction of silane–acrylate chemistry. Resulting photopolymer networks exhibit a homogeneous network architecture (indicated by a narrow glass transition) that can be tuned by varying silane concentration, and this confirms the postulated regulation of radical network formation. Similar to thiol–acrylate networks, this leads to more flexible photopolymer networks with increased elongation at break and improved impact resistance. Additionally, swelling tests indicate a high gel fraction for silane–acrylate photopolymers. PMID:29033466

  19. Effect of nanosilver on thermal and mechanical properties of acrylic base complete dentures.

    OpenAIRE

    Fahimeh Hamedi-Rad; Tahereh Ghaffari; Farzad Rezaii; Ali Ramazani

    2014-01-01

    Objective: Polymethyl methacrylate (PMMA), widely used as a prosthodontic base, has many disadvantages, including a high thermal expansion coefficient and low thermal conductivity, a low elasticity coefficient, low impact strength and low resistance to fatigue. This study aimed to make an in vitro comparison of the thermal conductivity, compressive strength, and tensile strength of the acrylic base of complete dentures with those of acrylic reinforced with nanosilver. Materials and Methods: F...

  20. The effect of various frequencies of ultrasonic cleaner in reducing residual monomer in acrylic resin.

    Science.gov (United States)

    Charasseangpaisarn, Taksid; Wiwatwarrapan, Chairat

    2015-12-01

    Monomer remaining in denture base acrylic can be a major problem because it may cause adverse effects on oral tissue and on the properties of the material. The purpose of this study was to compare the effect of various ultrasonic cleaner frequencies on the amount of residual monomer in acrylic resin after curing. Forty-two specimens each of Meliodent heat-polymerized acrylic resin (M) and Unifast Trad Ivory auto-polymerized acrylic resin (U) were prepared according to their manufacturer's instructions and randomly divided into seven groups: Negative control (NC); Positive control (PC); and five ultrasonic treatment groups: 28 kHz (F1), 40 kHz (F2), 60 kHz (F3) (M=10 min, U=5 min), and 28 kHz followed by 60 kHz (F4: M=5 min per frequency, U=2.5 min per frequency, and F5: M=10 min followed by 5 min per frequency, U=5 min followed by 2.5 min per frequency). Residual monomer was determined by HPLC following ISO 20795-1. The data were analyzed by One-way ANOVA and Tukey HSD. There was significantly less residual monomer in the auto-polymerized acrylic resin in all ultrasonic treatment groups and the PC group than that of the NC group (pacrylic resin (p>0.05). The amount of residual monomer in heat-polymerized acrylic resin was significantly lower than that of auto-polymerized acrylic resin. In conclusion, ultrasonic treatment at low frequencies is recommended to reduce the residual monomer in auto-polymerized acrylic resin and this method is more practical in a clinical situation than previously recommended methods because of reduced chairside time. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Acrylic acid obtaining from methanol and acetic acid in the presence of complex oxide catalysts

    OpenAIRE

    Nebesnyi, Roman; Pikh, Zorian; Shpyrka, Iryna; Ivasiv, Volodymyr; Nebesna, Yulia; Fuch, Uliana

    2016-01-01

    The purpose of this work is to research process of single-stage acrylic acid obtaining from methanol and acetic acid, namely: to develop effective catalysts for the process of methanol oxidation to formaldehyde with its further aldol condensation with acetic acid to acrylic acid, and to determine optimum conditions for the process. Complex oxide catalysts consisting of oxides of boron, phosphorus, tungsten and vanadium supported on the silica gel have been investigated. The effect of vanadium...

  2. Synthesis of phosphorus-containing polyurethanes and poly(urethane-acrylate)s

    OpenAIRE

    SÜDEMEN, MAHİR BURAK; ÖNEN, HACER AYŞEN

    2017-01-01

    Solvent-based polyurethanes and poly(urethane-acrylate)s were synthesized using phosphorus-containing polyester polyols in order to compare the thermal properties of different polymer types. Since the location of the phosphorus group might have vital importance when comparing the thermal properties, phosphorus groups were kept on the pendant chains in poly(urethane-acrylate)s using phosphorus-containing urethane macromonomers while they were kept on the backbone in polyurethanes. The effect o...

  3. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    OpenAIRE

    Paulo Maurício Batista da Silva; Emílio José Tabaré Rodríguez Acosta; Matheus Jacobina; Luciana de Rezende Pinto; Vinícius Carvalho Porto

    2011-01-01

    OBJECTIVE: Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. MATERIAL AND METHODS: Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture ...

  4. IN VITRO ANTIFUNGAL ACTION OF DIFFERENT SUBSTANCES OVER MICROWAVED-CURED ACRYLIC RESINS

    OpenAIRE

    Montagner, Henrique; Montagner, Francisco; Braun, Katia Olmedo; Peres, Paulo Edelvar Correa; Gomes, Brenda Paula Figueiredo de Almeida

    2009-01-01

    OBJECTIVE: The presence of Candida albicans on the surfaces of denture-base acrylic resins is strongly related to the development of oral stomatitis. This study evaluated the antifungal action of different agents over microwave-cured acrylic resin without polishing specimens previously contaminated with Candida albicans. MATERIAL AND METHODS: Sixty specimens were immersed in BHI broth previously inoculated with the yeast and stored for 3 h at 37ºC. They were divided into 5 experimental groups...

  5. Evaluation of surface physical properties of acrylic resins for provisional prosthesis

    OpenAIRE

    Hilgenberg, Sérgio Paulo; Orellana-Jimenez, Emigdio Enrique; Sepúlveda-Navarro, Wilmer Fabian; Arana-Correa, Beatriz Elena; Alves, Dario César Teixeira; Campanha, Nara Hellen

    2008-01-01

    Acrylic resins used for provisional prostheses should have satisfactory superficial characteristics in order to ensure gingival health and low bacterial attachment. The purpose of the present study was to evaluate the superficial roughness and contact angle after two types of polishing and the Vickers hardness of three acrylic resins (Duralay - G1, Dencrilay - G2, and Dencor - G3), all shade 66, indicated for provisional fixed prostheses. Five 20 x 3 ± 1 mm diameter discoid specimens were obt...

  6. Insights on the Biodegradation of Acrylic Reline Resins

    Science.gov (United States)

    Neves, Maria Cristina Bettencourt

    Acrylic reline resins are extensively used in dentistry, since they readapt dentures to the continuous reabsorbed underlying tissues. Since present in the oral cavity for long periods of time, these materials are objective of the biodegradation phenomena, which represents the change on their chemical, physical and mechanical properties due to the oral environment conditions and its constituents. These processes may permanently alter the properties of the material and compromise its function. In addition, they can promote leachable products, which in turn may induce a series of biological responses on cells and tissues. The biodegradation impact on the biocompatibility of acrylic materials is controversial but concern about its clinical significance is a fact as subjective and objective complaints about these materials are increasing. Acetylcholinesterase (AChE) has been reported to degrade methacrylatebased monomers and had a strong catalytic activity when tested in human saliva. Hence, it was the aim of chapter two of the current work to determine the effect of the enzyme AChE on the degradation of three acrylic reline resins, Probase Cold, Kooliner and Ufi Gel Hard, which contain the monomers methylmethacrylate (MMA), isobutylmethacrylate (IBMA) and 1,6-hexanodioldimethacrylate (HDMA), respectively, through the quantification of residual monomer and one common by-product methacrylic acid (MA) by High- Performance Liquid Chromatography (HPLC). These monomers were first incubated with AChE and their respective hydrolysis was monitored. The study of the degradation of the resins was done by incubating specimens of each material in 5 mL of buffer or 5 mL of buffer with AChE at 5 U/mL (pH 7.4, 37º C) for 72 h. To simulate the short-term and a long-term usage of the resins in the oral cavity, two endpoints were established: immediate exposure and late exposure. Immediate exposure was studied in eluates of specimens incubated immediately after polymerization. Late

  7. Dimensional change of acrylic resin plate after the reinforcement of glass fibre

    Directory of Open Access Journals (Sweden)

    Dwiyanti Feriana Ratwita

    2007-06-01

    Full Text Available The effect of fibre reinforcement of polymethyl methacrylate was investigated. Glass fibres have been studied as strengthening material added to polymethyl methacrylate. The purpose of this study was to evaluate dimensional change of acrylic resin plate after glass fibre reinforcement. As a research subject is an acrylic resin plate of 65 × 10 × 2.5 mm with the number of 32 samples were distributed randomly in 4 experimental groups. Each group consisted of 8 samples and control groups. Group 1: acrylic resin plate and 1 sheet glass fibre; group 2: acrylic resin plate and 2 sheet glass fibre; group 3: acrylic resin plate and 3 sheet glass fibre. Control group which was not given treatment. Dimensional change was measured by profile projector. The data was analyzed by One-Way ANOVA and LSD test showed that there was significant difference in dimensional change (p < 0.005. The conclusion suggested that dimensional change of the acrylic resin plates after glass fibre reinforcement minimally done 1 sheet glass fibre.

  8. Quantification and identification of bacteria in acrylic resin dentures and dento-maxillary obturator-prostheses.

    Science.gov (United States)

    Takeuchi, Yasuhisa; Nakajo, Kazuko; Sato, Takuichi; Koyama, Shigeto; Sasaki, Keiichi; Takahashi, Nobuhiro

    2012-06-01

    To quantify and identify bacteria detected in acrylic resin dentures and dento-maxillary obturator-prostheses after long-term use. The internal layer of denture bases from 13 daily-use removable acrylic resin dentures was sampled, while the inner fluid samples/no-fluid samples of obturators were collected from 11 in-use acrylic resin dento-maxillary obturator-prostheses. Samples were cultured, and isolated bacteria were counted and identified by molecular biological methods. Bacteria were detected in five (38.5%) acrylic resin dentures and six (54.5%) acrylic resin obturators. Four Lactobacillus species and one Propionibacterium species were isolated from three repaired denture bases, and from two non-repaired dentures, two Actinomyces species and Streptococcus mutans were isolated. On the other hand, 17 bacterial species, belonging to the family and genera of Olsenella, Bacillus, Citrobacter, Enterobacteriaceae, Lactobacillus, Pantoea, Peptoniphilus, Klebsiella and Pseudomonas, were isolated from obturators. Several species of viable bacteria were detected in acrylic resin denture bases and obturators.

  9. Mechanistic insight into acrylate metabolism and detoxification in marine dimethylsulfoniopropionate-catabolizing bacteria.

    Science.gov (United States)

    Wang, Peng; Cao, Hai-Yan; Chen, Xiu-Lan; Li, Chun-Yang; Li, Ping-Yi; Zhang, Xi-Ying; Qin, Qi-Long; Todd, Jonathan D; Zhang, Yu-Zhong

    2017-09-01

    Dimethylsulfoniopropionate (DMSP) cleavage, yielding dimethyl sulfide (DMS) and acrylate, provides vital carbon sources to marine bacteria, is a key component of the global sulfur cycle and effects atmospheric chemistry and potentially climate. Acrylate and its metabolite acryloyl-CoA are toxic if allowed to accumulate within cells. Thus, organisms cleaving DMSP require effective systems for both the utilization and detoxification of acrylate. Here, we examine the mechanism of acrylate utilization and detoxification in Roseobacters. We propose propionate-CoA ligase (PrpE) and acryloyl-CoA reductase (AcuI) as the key enzymes involved and through structural and mutagenesis analyses, provide explanations of their catalytic mechanisms. In most cases, DMSP lyases and DMSP demethylases (DmdAs) have low substrate affinities, but AcuIs have very high substrate affinities, suggesting that an effective detoxification system for acylate catabolism exists in DMSP-catabolizing Roseobacters. This study provides insight on acrylate metabolism and detoxification and a possible explanation for the high K m values that have been noted for some DMSP lyases. Since acrylate/acryloyl-CoA is probably produced by other metabolism, and AcuI and PrpE are conserved in many organisms across all domains of life, the detoxification system is likely relevant to many metabolic processes and environments beyond DMSP catabolism. © 2017 John Wiley & Sons Ltd.

  10. Steel Protective Coating Based on Plasticized Epoxy Acrylate Formulation Cured by Electron Beam Irradiation

    International Nuclear Information System (INIS)

    Ibrahim, M.S.; Said, H.M.; Mohamed, I.M.; Mohamed, H.A.; Kandile, N.G.

    2011-01-01

    Electron beam (EB) was used to cure coatings based on epoxy acrylate oligomer (EA) and different plasticizers such as epoxidized soybean oil, glycerol and castor oil. The effect of irradiation doses (10, 25, 50 kGy) on the curing epoxy acrylate formulations containing plasticizers was studied. In the addition, the effect of the different plasticizers on the end use performance properties of epoxy acrylate coatings such as hardness, bending, adhesion, acid and alkali resistance tests were investigated. It was observed that the incorporation of castor oil in epoxy acrylate, diluted by 1,6 hexandiol diacrylate monomer (HD) with a ratio (EA 70%, HD 20%, castor oil 10%) under the dose 10 kGy improved the physical, chemical and mechanical properties of cured films than the other plasticizers. On the other hand, sunflower free fatty acids were epoxidized in-situ under well established conditions and then was subjected to react with aniline in sealed ampoules under inert atmosphere at 140 degree C. The produced adduct was added at different concentrations to epoxy acrylate coatings under certain EB irradiation dose and then evaluated as corrosion inhibitors for carbon steel surfaces in terms of weight loss measurements and corrosion resistance tests. It was observed that the formula containing 0.4 gm of aniline adduct / 100 gm epoxy acrylate resin gave the best corrosion protection for carbon steel

  11. Effect of autoclave postpolymerization treatments on the fracture toughness of autopolymerizing dental acrylic resins.

    Science.gov (United States)

    Durkan, Rukiye; Gürbüz, Ayhan; Yilmaz, Burak; Özel, M Birol; Bağış, Bora

    2012-06-26

    Microwave and water bath postpolymerization have been suggested as methods to improve the mechanical properties of heat and autopolymerizing acrylic resins. However, the effects of autoclave heating on the fracture properties of autopolymerizing acrylic resins have not been investigated. The aim of this study was to assess the effectiveness of various autoclave postpolymerization methods on the fracture properties of 3 different autopolymerizing acrylic resins. Forty-two specimens of 3 different autopolymerizing acrylic resins (Orthocryl, Paladent RR and Futurajet) were fabricated (40x8x4mm), and each group was further divided into 6 subgroups (n=7). Control group specimens remained as processed (Group 1). The first test group was postpolymerized in a cassette autoclave at 135°C for 6 minutes and the other groups were postpolymerized in a conventional autoclave at 130°C using different time settings (5, 10, 20 or 30 minutes). Fracture toughness was then measured with a three-point bending test. Data were analyzed by ANOVA followed by the Duncan test (α=0.05). The fracture toughness of Orthocryl and Paladent-RR acrylic resins significantly increased following conventional autoclave postpolymerization at 130°C for 10 minutes (Pautoclave postpolymerized Futurajet was not significantly different than its control specimens (Pautoclaved at 130°C for 10 minutes. Within the limitations of this study, it can be suggested that autoclave postpolymerization is an effective method for increasing the fracture toughness of tested autoploymerized acrylic resins.

  12. Epoxy-acrylic core-shell particles by seeded emulsion polymerization.

    Science.gov (United States)

    Chen, Liang; Hong, Liang; Lin, Jui-Ching; Meyers, Greg; Harris, Joseph; Radler, Michael

    2016-07-01

    We developed a novel method for synthesizing epoxy-acrylic hybrid latexes. We first prepared an aqueous dispersion of high molecular weight solid epoxy prepolymers using a mechanical dispersion process at elevated temperatures, and we subsequently used the epoxy dispersion as a seed in the emulsion polymerization of acrylic monomers comprising methyl methacrylate (MMA) and methacrylic acid (MAA). Advanced analytical techniques, such as scanning transmission X-ray microscopy (STXM) and peak force tapping atomic force microscopy (PFT-AFM), have elucidated a unique core-shell morphology of the epoxy-acrylic hybrid particles. Moreover, the formation of the core-shell morphology in the seeded emulsion polymerization process is primarily attributed to kinetic trapping of the acrylic phase at the exterior of the epoxy particles. By this new method, we are able to design the epoxy and acrylic polymers in two separate steps, and we can potentially synthesize epoxy-acrylic hybrid latexes with a broad range of compositions. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Unbonded Prestressed Columns for Earthquake Resistance

    Science.gov (United States)

    2012-05-01

    Modern structures are able to survive significant shaking caused by earthquakes. By implementing unbonded post-tensioned tendons in bridge columns, the damage caused by an earthquake can be significantly lower than that of a standard reinforced concr...

  14. Tests on duralumin columns for aircraft construction

    Science.gov (United States)

    Lee, John G

    1924-01-01

    The following paper is based on the results of tests, upon duralumin columns, contained in two theses presented to the Department of Civil and Sanitary Engineering of the Massachusetts Institute of Technology.

  15. The Sports Column on National Daily Newspapers

    Directory of Open Access Journals (Sweden)

    Alp Çelik

    2015-10-01

    Full Text Available National daily newspapers aim to report detailed daily news. Sport pages of the newspapers contain sport columns and news about sport activities. The aim of this research was to investigate the sport columns appearing on sport pages of national daily newspapers published in Turkey. During the research process, nine national daily newspapers published in Turkey were reviewed for one year. The number of sport columns, publishing page, publishing space in cm. and accessibility of newspapers are ascertained. Newspaper field measurement, statistical and percentage calculations are made by Microsoft Excel. The study was completed with the transfer of the data obtained from Excel to Word as a document. According to the obtained data, regarding the news density on sport columns; Milliyet has the most news published, Cumhuriyet has the most news on front page, Haber Turk has the most space allocated and Zaman has been the most accessible newspaper.

  16. PRTR ion exchange vault column sampling

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1995-01-01

    This report documents ion exchange column sampling and Non Destructive Assay (NDA) results from activities in 1994, for the Plutonium Recycle Test Reactor (PRTR) ion exchange vault. The objective was to obtain sufficient information to prepare disposal documentation for the ion exchange columns found in the PRTR Ion exchange vault. This activity also allowed for the monitoring of the liquid level in the lower vault. The sampling activity contained five separate activities: (1) Sampling an ion exchange column and analyzing the ion exchange media for purpose of waste disposal; (2) Gamma and neutron NDA testing on ion exchange columns located in the upper vault; (3) Lower vault liquid level measurement; (4) Radiological survey of the upper vault; and (5) Secure the vault pending waste disposal

  17. Thermal post-buckling of slender composite and FGM columns ...

    Indian Academy of Sciences (India)

    G Venkateswara Rao

    column or plate. Structural members such as columns/beams are basic components in many light weight applications of the structural systems. The columns/ beams, having axially immovable ends, experience axial compressive mechanical load ...

  18. Capacity of columns with splice imperfections

    International Nuclear Information System (INIS)

    Popov, E.P.; Stephen, R.M.

    1977-01-01

    To study the behavior of spliced columns subjected to tensile forces simulating situations which may develop in an earthquake, all of the spliced specimens were tested to failure in tension after first having been subjected to large compressive loads. The results of these tests indicate that the lack of perfect contact at compression splices of columns may not be important, provided that the gaps are shimmed and welding is used to maintain the sections in alignment

  19. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  20. Interpretation of the lime column penetration test

    International Nuclear Information System (INIS)

    Liyanapathirana, D S; Kelly, R B

    2010-01-01

    Dry soil mix (DSM) columns are used to reduce the settlement and to improve the stability of embankments constructed on soft clays. During construction the shear strength of the columns needs to be confirmed for compliance with technical assumptions. A specialized blade shaped penetrometer known as the lime column probe, has been developed for testing DSM columns. This test can be carried out as a pull out resistance test (PORT) or a push in resistance test (PIRT). The test is considered to be more representative of average column shear strength than methods that test only a limited area of the column. Both PORT and PIRT tests require empirical correlations of measured resistance to an absolute measure of shear strength, in a similar manner to the cone penetration test. In this paper, finite element method is used to assess the probe factor, N, for the PORT test. Due to the large soil deformations around the probe, an Arbitrary Lagrangian Eulerian (ALE) based finite element formulation has been used. Variation of N with rigidity index and the friction at the probe-soil interface are investigated to establish a range for the probe factor.

  1. Development of spent salt treatment technology by zeolite column system. Performance evaluation of zeolite column

    International Nuclear Information System (INIS)

    Miura, Hidenori; Uozumi, Koichi

    2009-01-01

    At electrorefining process, fission products(FPs) accumulate in molten salt. To avoid influence on heating control by decay heat and enlargement of FP amount in the recovered fuel, FP elements must be removed from the spent salt of the electrorefining process. For the removal of the FPs from the spent salt, we are investigating the availability of zeolite column system. For obtaining the basic data of the column system, such as flow property and ion-exchange performance while high temperature molten salt is passing through the column, and experimental apparatus equipped with fraction collector was developed. By using this apparatus, following results were obtained. 1) We cleared up the flow parameter of column system with zeolite powder, such as flow rate control by argon pressure. 2) Zeolite 4A in the column can absorb cesium that is one of the FP elements in molten salt. From these results, we got perspective on availability of the zeolite column system. (author)

  2. Structural Decoupling and Disturbance Rejection in a Distillation Column

    DEFF Research Database (Denmark)

    Bahar, Mehrdad; Jantzen, Jan; Commault, C.

    1996-01-01

    Introduction, distillation column model, input-output decoupling, disturbance rejection, concluding remarks, references.......Introduction, distillation column model, input-output decoupling, disturbance rejection, concluding remarks, references....

  3. Fabricating of full denture acrylic protheses with palatine torus

    Directory of Open Access Journals (Sweden)

    Ima Hariyati

    2016-06-01

    Full Text Available Full denture acrylic protheses can substitute all maxillary or mandibulary teeth naturally. The objective of fabricating full denture protheses is to substitute the tissue lost that was occupied by teeth or connective tissue before ward. This is a case of a 43 year old female with lost of all her upper and lower teeth. At the maxilla there is a palatine torus spreading along the midline with 25 mm length, 10 mm width and 6mm height. She has never worn prothese before. The process of full denture protheses fabrication were carried out in several steps, starting from making anatomical impression  to get study model, making of individual stock tray, making functional impression to get working model, choosing the design, making of midline, making of bite rim, inserting the model on articulator, preparing artificial teeth arrangement, fitting the wax, countoring wax, flasking, boiling out, packing, curing, deflasking, finishing, polishing and inserting the protheses. The process of this full denture protheses fabrication used tin foil as reducer to prevent overpressure of the tissue around the thin torus area so the prothesis will be more comfortable for the patient. The result was the protheses can be used by the patient, nicely and comfortably.

  4. Synthesis of acrylates and methacrylates from coal-derived syngas

    Energy Technology Data Exchange (ETDEWEB)

    Spivey, J.J.; Gogate, M.R.; Jang, B.W.L. [Bechtel, San Francisco, CA (United States)] [and others

    1995-12-31

    Acrylates and methacrylates are among the most widely used chemical intermediates in the world. One of the key chemicals of this type is methyl methacrylate. Of the 4 billion pounds produced each year, roughly 85% is made using the acetone-cyanohydrin process, which requires handling of large quantities of hydrogen cyanide and produces ammonium sulfate wastes that pose an environmental disposal challenge. The U.S. Department of Energy and Eastman Chemical Company are sharing the cost of research to develop an alternative process for the synthesis of methyl methacrylate from syngas. Research Triangle Institute is focusing on the synthesis and testing of active catalysts for the condensation reactions, and Bechtel is analyzing the costs to determine the competitiveness of several process alternatives. Results thus far show that the catalysts for the condensation of formaldehyde and the propionate are key to selectively producing the desired product, methacrylic acid, with a high yield. These condensation catalysts have both acid and base functions and the strength and distribution of these acid-base sites controls the product selectivity and yield.

  5. Synthesis, characterization and antimicrobial activity of important heterocyclic acrylic copolymers

    Directory of Open Access Journals (Sweden)

    2008-10-01

    Full Text Available The acrylate monomer, 7-acryloyloxy-4-methyl coumarin (AMC has been synthesized by reacting 7-hydroxy-4-methyl coumarin, with acryloyl chloride in the presence of NaOH at 0–5°C. Copolymers of 7-acryloyloxy-4-methyl coumarin (AMC with vinyl acetate (VAc were synthesized in DMF (dimethyl formamide solution at 70±1°C using 2,2′-azobisisobutyronitrile (AIBN as an initiator with different monomer-to-monomer ratios in the feed. The copolymers were characterized by Fourier transform infra red (FTIR spectroscopy. The copolymer composition was evaluated by 1H-NMR (proton nuclear magnetic resonance and was further used to determine reactivity ratios. The monomer reactivity ratios for AMC (M1-VAc (M2 pair were determined by the application of conventional linearization methods such as Fineman-Ross (r1 = 0.6924; r2 = 0.6431, Kelen-Tüdõs (r1 = 0.6776; r2 = 0.6374 and extended Kelen-Tüdõs (r1 = 0.6657; r2 = 0.6256. Thermo gravimetric analysis showed that thermal decomposition of the copolymers occurred in single stage in the temperature range of 263–458°C. The molecular weights of the polymers were determined using gel permeation chromatography. The homo and copolymers were tested for their antimicrobial properties against selected microorganisms.

  6. Characterization of Functionalized Acrylic acid /4- Vinyl Pyridine Graft Copolymers

    International Nuclear Information System (INIS)

    Kamal, H.; Mahmoud, Gh.A.; Hegazy, D.E.

    2009-01-01

    Properties and characterization of the membranes prepared by radiation grafting of acrylic acid (AAc) or/ and 4-vinyl pyridine (4VP) onto low density polyethylene (LDPE) and polypropylene (PP) films were carried out. The FTIR spectra for the grafted membranes were studied to evaluate the structure change as a result of grafting. The swelling behaviour of the graft copolymer in methanol was studied. It was found that the grafting of AAc and/ or 4- VP onto LDPE and PP resulted in introducing good hydrophilic properties to such polymer substrates. The hydrophilic properties were directly proportional to the amount of functional groups. The mechanical properties (Young's modulus, elongation percent and tensile strength) of the grafted membranes also, have been investigated. As the grafting degree increases, the modulus also increases. Increasing the hydrophilicity of the membranes by chemical treatment enhances its mechanical properties. The thermal parameters of the grafted membranes such as δH m1 . δH m2 , and T rc have been also studied by using DSC

  7. Icephobicity of polydimethylsiloxane-b-poly(fluorinated acrylate)

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hui [School of Materials Science and Engineering, Tianjin University, Tianjin 300072 (China); Tianjin Key Laboratory of Composite and Functional Materials, Tianjin 300072 (China); School of Chemistry and Chemical Engineering, Shandong Key Laboratory of Fluorine Chemistry and Chemical Engineering Materials, University of Jinan, Jinan 250022 (China); Li, Xiaohui; Luo, Chenghao; Zhao, Yunhui [School of Materials Science and Engineering, Tianjin University, Tianjin 300072 (China); Tianjin Key Laboratory of Composite and Functional Materials, Tianjin 300072 (China); Yuan, Xiaoyan, E-mail: yuanxy@tju.edu.cn [School of Materials Science and Engineering, Tianjin University, Tianjin 300072 (China); Tianjin Key Laboratory of Composite and Functional Materials, Tianjin 300072 (China)

    2014-12-31

    A facile process to fabricate icephobic surfaces was developed by spin-coating the polydimethylsiloxane-b-poly(fluorinated acrylate) (PDMS-b-PFA) block copolymers on the substrate. The surface microstructure and chemical composition of the block copolymer films can be adjusted by changing the PDMS content. Icephobic properties of the copolymer surface were mainly ascribed to “flexible-hard” microphase separation and the ratio of fluorine to silicon. The appropriate microphase domain size and the fluorine/silicon ratio could weaken the interaction of ice and copolymer surface and delay icing of water droplets on the copolymer surface. The copolymers containing 15 wt.% PDMS showed the most outstanding icephobicity by depressing the interaction between ice and the copolymer surface. - Highlights: • PDMS-b-PFA block copolymers with different PDMS contents were synthesized. • Surface microstructure can be adjusted by changing the content of PDMS. • The ratio of fluorine/silicon increased with the decrease of the PDMS content. • Ice adhesion and shear strength were decreased by the synergistic effect of silicon and fluorine.

  8. Cytocompatible antifungal acrylic resin containing silver nanoparticles for dentures

    Science.gov (United States)

    Acosta-Torres, Laura Susana; Mendieta, Irasema; Nuñez-Anita, Rosa Elvira; Cajero-Juárez, Marcos; Castaño, Víctor M

    2012-01-01

    Background Inhibition of Candida albicans on denture resins could play a significant role in preventing the development of denture stomatitis. The safety of a new dental material with antifungal properties was analyzed in this work. Methods Poly(methyl methacrylate) [PMMA] discs and PMMA-silver nanoparticle discs were formulated, with the commercial acrylic resin, Nature-CrylTM, used as a control. Silver nanoparticles were synthesized and characterized by ultraviolet-visible spectroscopy, dispersive Raman spectroscopy, and transmission electron microscopy. The antifungal effect was assessed using a luminescent microbial cell viability assay. Biocompatibility tests were carried out using NIH-3T3 mouse embryonic fibroblasts and a Jurkat human lymphocyte cell line. Cells were cultured for 24 or 72 hours in the presence or absence of the polymer formulations and analyzed using three different tests, ie, cellular viability by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and cell proliferation by enzyme-linked immunosorbent assay BrdU, and genomic DNA damage (Comet assay). Finally, the samples were evaluated mechanically, and the polymer-bearing silver nanoparticles were analyzed microscopically to evaluate dispersion of the nanoparticles. Results The results show that PMMA-silver nanoparticle discs significantly reduce adherence of C. albicans and do not affect metabolism or proliferation. They also appear not to cause genotoxic damage to cells. Conclusion The present work has developed a new biocompatible antifungal PMMA denture base material. PMID:22969297

  9. Acoustic Performance of Resilient Materials Using Acrylic Polymer Emulsion Resin

    Directory of Open Access Journals (Sweden)

    Haseog Kim

    2016-07-01

    Full Text Available There have been frequent cases of civil complaints and disputes in relation to floor impact noises over the years. To solve these issues, a substantial amount of sound resilient material is installed between the concrete slab and the foamed concrete during construction. A new place-type resilient material is made from cement, silica powder, sodium sulfate, expanded-polystyrene, anhydrite, fly ash, and acrylic polymer emulsion resin. Its physical characteristics such as density, compressive strength, dynamic stiffness, and remanent strain are analyzed to assess the acoustic performance of the material. The experimental results showed the density and the dynamic stiffness of the proposed resilient material is increased with proportional to the use of cement and silica powder due to the high contents of the raw materials. The remanent strain, related to the serviceability of a structure, is found to be inversely proportional to the density and strength. The amount of reduction in the heavyweight impact noise is significant in a material with high density, high strength, and low remanent strain. Finally, specimen no. R4, having the reduction level of 3 dB for impact ball and 1 dB for bang machine in the single number quantity level, respectively, is the best product to obtain overall acoustic performance.

  10. Strategic design and fabrication of acrylic shape memory polymers

    Science.gov (United States)

    Park, Ju Hyuk; Kim, Hansu; Ryoun Youn, Jae; Song, Young Seok

    2017-08-01

    Modulation of thermomechanics nature is a critical issue for an optimized use of shape memory polymers (SMPs). In this study, a strategic approach was proposed to control the transition temperature of SMPs. Free radical vinyl polymerization was employed for tailoring and preparing acrylic SMPs. Transition temperatures of the shape memory tri-copolymers were tuned by changing the composition of monomers. X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy analyses were carried out to evaluate the chemical structures and compositions of the synthesized SMPs. The thermomechanical properties and shape memory performance of the SMPs were also examined by performing dynamic mechanical thermal analysis. Numerical simulation based on a finite element method provided consistent results with experimental cyclic shape memory tests of the specimens. Transient shape recovery tests were conducted and optical transparence of the samples was identified. We envision that the materials proposed in this study can help develop a new type of shape-memory devices in biomedical and aerospace engineering applications.

  11. Rat hindlimb joint immobilization with acrylic resin orthoses

    Directory of Open Access Journals (Sweden)

    C.A. da Silva

    2006-07-01

    Full Text Available The objective of the present study was to propose an orthosis of light material that would be functional for the animal and that would maintain only the ankle joint immobilized. Male Wistar rats (3 to 4 months old, 250-300 g were divided into 2 groups (N = 6: control and immobilized for 7 days. Rats were anesthetized with sodium pentobarbital (40 mg/kg weight and the left hindlimb was immobilized with the orthoses composed of acrylic resin model, abdominal belt and lateral supports. The following analyses were performed: glycogen content of the soleus, extensor digitorum longus, white gastrocnemius, red gastrocnemius, and tibialis anterior muscles by the phenol sulfuric method, and the weight, fiber area and intramuscular connective tissue of the soleus by the planimetric system. Data were analyzed statistically by the Kolmogorov-Smirnov, Student t and Wilcoxon tests. Immobilization decreased glycogen in all muscles (P < 0.05; soleus: 31.6%, white gastrocnemius: 56.6%, red gastrocnemius: 39%, extensor digitorum longus: 41.7%, tibialis anterior: 45.2% in addition to reducing soleus weight by 34% (P < 0.05. Furthermore, immobilization promoted reduction of the fiber area (43%, P < 0.05 and increased the connective tissue (200%, P < 0.05. The orthosis model was efficient comparing with another alternative immobilization model, like plaster casts, in promoting skeletal muscle alterations, indicating that it could be used as a new model in other studies related to muscle disuse.

  12. Acoustic Performance of Resilient Materials Using Acrylic Polymer Emulsion Resin.

    Science.gov (United States)

    Kim, Haseog; Park, Sangki; Lee, Seahyun

    2016-07-19

    There have been frequent cases of civil complaints and disputes in relation to floor impact noises over the years. To solve these issues, a substantial amount of sound resilient material is installed between the concrete slab and the foamed concrete during construction. A new place-type resilient material is made from cement, silica powder, sodium sulfate, expanded-polystyrene, anhydrite, fly ash, and acrylic polymer emulsion resin. Its physical characteristics such as density, compressive strength, dynamic stiffness, and remanent strain are analyzed to assess the acoustic performance of the material. The experimental results showed the density and the dynamic stiffness of the proposed resilient material is increased with proportional to the use of cement and silica powder due to the high contents of the raw materials. The remanent strain, related to the serviceability of a structure, is found to be inversely proportional to the density and strength. The amount of reduction in the heavyweight impact noise is significant in a material with high density, high strength, and low remanent strain. Finally, specimen no. R4, having the reduction level of 3 dB for impact ball and 1 dB for bang machine in the single number quantity level, respectively, is the best product to obtain overall acoustic performance.

  13. Cytocompatible antifungal acrylic resin containing silver nanoparticles for dentures.

    Science.gov (United States)

    Acosta-Torres, Laura Susana; Mendieta, Irasema; Nuñez-Anita, Rosa Elvira; Cajero-Juárez, Marcos; Castaño, Víctor M

    2012-01-01

    Inhibition of Candida albicans on denture resins could play a significant role in preventing the development of denture stomatitis. The safety of a new dental material with antifungal properties was analyzed in this work. Poly(methyl methacrylate) [PMMA] discs and PMMA-silver nanoparticle discs were formulated, with the commercial acrylic resin, Nature-Cryl™, used as a control. Silver nanoparticles were synthesized and characterized by ultraviolet-visible spectroscopy, dispersive Raman spectroscopy, and transmission electron microscopy. The antifungal effect was assessed using a luminescent microbial cell viability assay. Biocompatibility tests were carried out using NIH-3T3 mouse embryonic fibroblasts and a Jurkat human lymphocyte cell line. Cells were cultured for 24 or 72 hours in the presence or absence of the polymer formulations and analyzed using three different tests, ie, cellular viability by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, and cell proliferation by enzyme-linked immunosorbent assay BrdU, and genomic DNA damage (Comet assay). Finally, the samples were evaluated mechanically, and the polymer-bearing silver nanoparticles were analyzed microscopically to evaluate dispersion of the nanoparticles. The results show that PMMA-silver nanoparticle discs significantly reduce adherence of C. albicans and do not affect metabolism or proliferation. They also appear not to cause genotoxic damage to cells. The present work has developed a new biocompatible antifungal PMMA denture base material.

  14. A stability study of plasma polymerized acrylic acid films

    Science.gov (United States)

    Cools, Pieter; Declercq, Heidi; De Geyter, Nathalie; Morent, Rino

    2018-02-01

    A medium pressure parallel-plate DBD set-up was used for the deposition of carboxylic acid-rich films using acrylic acid as precursor. A variety of discharge powers (21-33 W) and monomer flow rates (0.25-0.5 g/h) were applied to develop a range of coatings from highly unstable to completely stable in aqueous solutions. FT-IR and XPS were used to identify which coatings were stable under dynamic incubation conditions and what influence plasma operating parameters had on functional group preservation. White light interferometry was also used to calculate deposition rates (66-126 nm/min) and to determine the deposition regime (monomer deficient). Human foreskin fibroblasts were seeded onto the complete range of investigated samples and the effects of coating (in)stability on cell adhesion, viability and morphology were systematically studied. Results showed that the 27 W-0.25 g/h treatment conditions resulted in the most stable coatings. Although a concentration of only 0.7% of carboxylic acid groups was found under these experimental conditions, the positive effects of a highly acid-rich surface were still maintained as cell-material interactions were significantly enhanced.

  15. Radiation-induced synthesis of poly(acrylic acid) nanogels

    Science.gov (United States)

    Matusiak, Malgorzata; Kadlubowski, Slawomir; Ulanski, Piotr

    2018-01-01

    Nanogel is a two-component system of a diameter in the range of tens of nanometers, consisting of an intramolecularly crosslinked polymer chain and solvent, typically water, filling the space between segments of the macromolecule. Microgels are bigger than nanogels and their size range is between 100 nm to 100 μm. One of the methods used for synthesizing nanogels is linking the segments of a single macromolecule with the use of ionizing radiation, by intramolecular recombination of radiation-generated polymer radicals. The main advantage of this technique is absence of monomers, catalysts, surfactants or crosslinking agents. This method is an interesting alternative way of synthesizing polymeric carriers for biomedical applications. The aim of the study was radiation synthesis and characterization of poly(acrylic acid) - PAA - nanogels and microgels. The physico-chemical properties were described by determination of weight-average molecular weight and dimensions (radius of gyration, hydrodynamic radius) of the nanogels and microgels. Influence of polymer concentration and dose on these parameters was analyzed. Adjusting the PAA concentration and absorbed dose, one can control the molecular weight and dimensions of nanogels. The solutions of PAA were irradiated with two sources of ionizing radiation: γ-source and electron accelerator. The former method yields mainly microgels due to prevailing intermolecular crosslinking, while the latter promotes intramolecular recombination of PAA-derived radicals and in consequence formation of nanogels. In the future radiation-synthesized PAA nanogels, after functionalization, will be tested as carriers for delivering radionuclides to the tumor cells.

  16. Preparation and magnetic properties of polymer magnetic composites based on acrylate resin filled with nickel plating graphite nanosheets

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yi, E-mail: zhangyi520love@yahoo.com.cn [Department of Applied Chemistry, School of Science, Northwestern Polytechnical University, Xi' an 710072 (China); Qi Shuhua; Zhang Fan; Yang Yongqing; Duan Guochen [Department of Applied Chemistry, School of Science, Northwestern Polytechnical University, Xi' an 710072 (China)

    2011-11-01

    Nickel plating graphite nanosheets (Ni/GNs) were prepared by electroless plating method using graphite nanosheets (GNs). Then a novel polymer magnetic composites based on acrylate pressure-sensitive adhesive (acrylate PSA) filled with Ni/GNs were fabricated by solution blend method. The Ni/GNs and acrylate PSA/Ni/GNs composites were characterized by scanning electron microscope (SEM)/energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), vibrating sample magnetometer (VSM) and transmission electron microscope (TEM). All results showed that relatively uniform and compact Ni layer is successfully coated onto GNs under the given conditions, furthermore, Ni/GNs are homogeneously dispersed in acrylate PSA. The VSM results showed that the saturation magnetization of acrylate PSA/Ni/GNs composites increases with an increasing content of Ni/GNs while the coercivity decreases with an increasing content of Ni/GNs. When the content of GNs is 20 wt%, acrylate PSA/Ni/GNs composites exhibites good mechanical properties.

  17. Preparation and magnetic properties of polymer magnetic composites based on acrylate resin filled with nickel plating graphite nanosheets

    International Nuclear Information System (INIS)

    Zhang Yi; Qi Shuhua; Zhang Fan; Yang Yongqing; Duan Guochen

    2011-01-01

    Nickel plating graphite nanosheets (Ni/GNs) were prepared by electroless plating method using graphite nanosheets (GNs). Then a novel polymer magnetic composites based on acrylate pressure-sensitive adhesive (acrylate PSA) filled with Ni/GNs were fabricated by solution blend method. The Ni/GNs and acrylate PSA/Ni/GNs composites were characterized by scanning electron microscope (SEM)/energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), vibrating sample magnetometer (VSM) and transmission electron microscope (TEM). All results showed that relatively uniform and compact Ni layer is successfully coated onto GNs under the given conditions, furthermore, Ni/GNs are homogeneously dispersed in acrylate PSA. The VSM results showed that the saturation magnetization of acrylate PSA/Ni/GNs composites increases with an increasing content of Ni/GNs while the coercivity decreases with an increasing content of Ni/GNs. When the content of GNs is 20 wt%, acrylate PSA/Ni/GNs composites exhibites good mechanical properties.

  18. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    Science.gov (United States)

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  19. Low-Cost, Manufacturable, 6-Inch Wafer Bonding Process for Next-Generation 5-Junction IMM+Ge Photovoltaic Devices Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a 6-inch wafer bonding process to allow bonding of a multi-junction inverted metamorphic (IMM) tandem solar cell structure to an...

  20. MRIR/Nimbus-2 Images of Daytime Brightness Temperature on 4 x 5 inch Film Sheets V001 (MRIRN2IM) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — MRIRN2IM is the Nimbus-2 Medium Resolution Infrared Radiometer (MRIR) data product consisting of 4 x 5 inch photographic film sheets. Each film sheet contains an...

  1. MRIR/Nimbus-3 Images of Daytime Brightness Temperature on 4 x 5 inch Film Sheets V001 (MRIRN3IM) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — MRIRN3IM is the Nimbus-3 Medium Resolution Infrared Radiometer (MRIR) data product consisting of 4 x 5 inch photographic film sheets. Each film sheet contains an...

  2. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    OpenAIRE

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A.

    2016-01-01

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufactur...

  3. Preparation and Application of Crosslinked Poly(sodium acrylate)-Coated Magnetite Nanoparticles as Corrosion Inhibitors for Carbon Steel Alloy

    OpenAIRE

    Ayman M. Atta; Gamal A. El-Mahdy; Hamad A. Al-Lohedan; Ashraf M. El-Saeed

    2015-01-01

    This work presents a new method to prepare poly(sodium acrylate) magnetite composite nanoparticles. Core/shell type magnetite nanocomposites were synthesized using sodium acrylate as monomer and N,N-methylenebisacrylamide (MBA) as crosslinker. Microemulsion polymerization was used for constructing core/shell structures with magnetite nanoparticles as core and poly(sodium acrylate) as shell. Fourier transform infrared spectroscopy (FTIR) was employed to characterize the nanocomposite chemical ...

  4. Effect of "hard" comonomers styrene and methyl methacrylate in ethyl acrylate/acrylic acid latices on their thickening with associative thickener

    Czech Academy of Sciences Publication Activity Database

    Quadrat, Otakar; Šňupárek, J.; Mikešová, Jana; Horský, Jiří

    2005-01-01

    Roč. 253, 1-3 (2005), s. 163-168 ISSN 0927-7757 R&D Projects: GA AV ČR GA104/02/1360 Institutional research plan: CEZ:AV0Z40500505 Keywords : latices * thickening * acrylic copolymers containing styrene or methyl methacrylate groups Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.499, year: 2005

  5. Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

  6. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  7. Structural degradation of acrylic bone cements due to in vivo and simulated aging.

    Science.gov (United States)

    Hughes, Kerry F; Ries, Michael D; Pruitt, Lisa A

    2003-05-01

    Acrylic bone cement is the primary load-bearing material used for the attachment of orthopedic devices to adjoining bone. Degradation of acrylic-based cements in vivo results in a loss of structural integrity of the bone-cement-prosthesis interface and limits the longevity of cemented orthopedic implants. The purpose of this study is to investigate the effect of in vivo aging on the structure of the acrylic bone cement and to develop an in vitro artificial aging protocol that mimics the observed degradation. Three sets of retrievals are examined in this study: Palacos brand cement retrieved from hip replacements, and Simplex brand cement retrieved from both hip and knee replacement surgeries. In vitro aging is performed using oxidative and acidic environments on three acrylic-based cements: Palacos, Simplex, and CORE. Gel permeation chromatography (GPC) and Fourier transform infrared spectroscopy (FTIR) are used to examine the evolution of molecular weight and chemical species within the acrylic cements due to both in vivo and simulated aging. GPC analysis indicates that molecular weight is degraded in the hip retrievals but not in the knee retrievals. Artificial aging in an oxidative environment best reproduces this degradation mechanism. FTIR analysis indicates that there exists a chemical evolution within the cement due to in vivo and in vitro aging. These findings are consistent with scission-based degradation schemes in the cement. Based on the results of this study, a pathway for structural degradation of acrylic bone cement is proposed. The findings from this investigation have broad applicability to acrylic-based cements and may provide guidance for the development of new bone cements that resist degradation in the body. Copyright 2003 Wiley Periodicals, Inc.

  8. Causes and pattern of fracture of acrylic dentures among patients seen in a Nigerian teaching hospital.

    Science.gov (United States)

    Ogunrinde, T J; Ajayi, D M; Dosumu, O O

    2007-12-01

    There is little information on the causes and pattern of fracture of acrylic dentures in Nigerian patients despite being the most frequently employed design in Nigeria. The aim of this study was to determine the average life span of acrylic dentures before fracture, the causes and pattern of fracture of acrylic dentures in a Nigerian population. All consecutive patients that presented with fractured acrylic dentures at the Dental Centre, University College Hospital, Ibadan between January and July 2006 and were willing to participate were recruited into the study. A structured interviewer-administered questionnaire was used to record data from the patients. The questionnaire focused on patients' demographic data, age of acrylic denture as at the time of fracture, causes and pattern of fractures. The data were analysed using SPSS Version 11. A total of sixty-two patients were included in the study. They presented with sixty-nine fractured dentures. Five were complete dentures while 64 were partial dentures. The average life span was 7.4 years +/- 6.6 (SD) years. Early fracture was seen in 9 (13.4%), intermediate fracture in 29 (42%), and late fracture in 31 (44.9%) cases. The commonest cause of fracture was mastication as seen in 30.4% of the cases while the least cause was fight (4.3%). The commonest site of fracture (34.8%) was the palatal plate around the crest of the edentulous ridge while fracture of wrought metal clasps was the least, occurring in 1.4% of cases. We recommend proper design with balanced articulation and more emphasis on compliance to post insertion instructions by patients to prevent early fracture of acrylic dentures. Also, reinforcing the acrylic denture base especially in stress bearing area may prolong the life span of these prostheses.

  9. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    Science.gov (United States)

    da SILVA, Paulo Maurício Batista; ACOSTA, Emílio José Tabaré Rodríguez; JACOBINA, Matheus; PINTO, Luciana de Rezende; PORTO, Vinícius Carvalho

    2011-01-01

    Objective Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Material and Methods Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. Results There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Conclusions Repeated immersion cycles in disinfecting solutions alter ∆E* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye. PMID:22230997

  10. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins

    Directory of Open Access Journals (Sweden)

    Paulo Maurício Batista da Silva

    2011-12-01

    Full Text Available OBJECTIVE: Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. MATERIAL AND METHODS: Sixty disc-shaped specimens (40 mm x 3 mm were fabricated from two different brands (Artiplus and Trilux of denture tooth acrylic resin. The specimens from each brand (n=30 were randomly divided into 6 groups (n=5 and immersed in the following solutions: distilled water (control group and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate. Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE* were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA followed by Tukey tests. The significance level was set at 5%. RESULTS: There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. CONCLUSIONS: Repeated immersion cycles in disinfecting solutions alter ΔE* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye.

  11. Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins.

    Science.gov (United States)

    Silva, Paulo Maurício Batista da; Acosta, Emílio José Tabaré Rodríguez; Jacobina, Matheus; Pinto, Luciana de Rezende; Porto, Vinícius Carvalho

    2011-01-01

    Chemical solutions have been widely used for disinfection of dentures, but their effect on color stability of denture tooth acrylic resins after repeated procedures is still unclear. The aim of this in vitro study was to evaluate whether repeated cycles of chemical disinfectants affected the color stability of two denture tooth acrylic resins. Sixty disc-shaped specimens (40 mm x 3 mm) were fabricated from two different brands (Artiplus and Trilux) of denture tooth acrylic resin. The specimens from each brand (n=30) were randomly divided into 6 groups (n=5) and immersed in the following solutions: distilled water (control group) and 5 disinfecting solutions (1% sodium hypochlorite, 2% sodium hypochlorite, 5.25% sodium hypochlorite, 2% glutaraldehyde, and 4% chlorhexidine gluconate). Tooth color measurements were made by spectrophotometry. Before disinfection, the initial color of each tooth was recorded. Further color measurements were determined after subjecting the specimens to 7, 21, 30, 45, 60, and 90 immersion cycles in each tested solution. Color differences (ΔE*) were determined using the CIE L*a*b* color system. Data were analyzed using two-way repeated measures analysis of variance (ANOVA) followed by Tukey tests. The significance level was set at 5%. There were statistically significant differences in ΔE* among the 5 disinfectants and water during the 90 cycles of immersion for both denture tooth acrylic resins. Distilled water promoted the greatest color change in both denture tooth acrylic resins, nevertheless none of tested disinfectants promoted ΔE* values higher than 1.0 on these acrylic materials during the 90 cycles of disinfection. Repeated immersion cycles in disinfecting solutions alter ΔE* values, however these values do not compromise the color of the tested denture tooth acrylic resins because they are imperceptible to the human eye.

  12. [Preparation of strong cation-exchange monolithic column and its application in polypeptide separation by capillary electrochromatography].

    Science.gov (United States)

    Qi, Nan; Cui, Ruihong; You, Huiyan

    2011-09-01

    A strong cation-exchange monolithic column was prepared by polymerization inside the fused-silica capillary. The solution consisted of acrylic acid and 2-acrylamido-2-methyl-1-propanesulfonic acid as functional monomers, N,N'-methylenebisacrylamide as a cross-linking agent, dimethyl suiphoxide and dodecanol, 1 , 4-butanediol as organic porogenic solvents and azobisisobutyronitrile as a suitable initiator. The effects of the applied voltage, concentrations of organic modifier and salt solution, pH value on the electroosmotic flow were investigated. The experimental results showed that there existed a good linear relationship between the applied voltage and electroosmotic flow with a correlation coefficient of 0.9981; When the concentration of organic modifier (acetonitrile, ACN) was less than 70%, the swelling degree of stationary phase played a main role and the electroosmotic flow was decreased abnormally with the increase of ACN concentration; The electroosmotic flow was decreased with the increase of the concentration of phosphate. When the pH value was in the range of 3-9, it did not exert a significant change in electroosmotic flow. These results were consistent with the theoretical role. At the same time, five peptides were separated successfully under the optimal experimental conditions on the monolithic column for capillary electrochromatography. The column has obvious advantages in polypeptide separation and will be favorable for the protein investigation.

  13. ON THE ORIGIN OF THE HIGH COLUMN DENSITY TURNOVER IN THE H I COLUMN DENSITY DISTRIBUTION

    International Nuclear Information System (INIS)

    Erkal, Denis; Gnedin, Nickolay Y.; Kravtsov, Andrey V.

    2012-01-01

    We study the high column density regime of the H I column density distribution function and argue that there are two distinct features: a turnover at N H I ≈ 10 21 cm –2 , which is present at both z = 0 and z ≈ 3, and a lack of systems above N H I ≈ 10 22 cm –2 at z = 0. Using observations of the column density distribution, we argue that the H I-H 2 transition does not cause the turnover at N H I ≈ 10 21 cm –2 but can plausibly explain the turnover at N H I ∼> 10 22 cm –2 . We compute the H I column density distribution of individual galaxies in the THINGS sample and show that the turnover column density depends only weakly on metallicity. Furthermore, we show that the column density distribution of galaxies, corrected for inclination, is insensitive to the resolution of the H I map or to averaging in radial shells. Our results indicate that the similarity of H I column density distributions at z = 3 and 0 is due to the similarity of the maximum H I surface densities of high-z and low-z disks, set presumably by universal processes that shape properties of the gaseous disks of galaxies. Using fully cosmological simulations, we explore other candidate physical mechanisms that could produce a turnover in the column density distribution. We show that while turbulence within giant molecular clouds cannot affect the damped Lyα column density distribution, stellar feedback can affect it significantly if the feedback is sufficiently effective in removing gas from the central 2-3 kpc of high-redshift galaxies. Finally, we argue that it is meaningful to compare column densities averaged over ∼ kpc scales with those estimated from quasar spectra that probe sub-pc scales due to the steep power spectrum of H I column density fluctuations observed in nearby galaxies.

  14. Contributions to reversed-phase column selectivity: III. Column hydrogen-bond basicity.

    Science.gov (United States)

    Carr, P W; Dolan, J W; Dorsey, J G; Snyder, L R; Kirkland, J J

    2015-05-22

    Column selectivity in reversed-phase chromatography (RPC) can be described in terms of the hydrophobic-subtraction model, which recognizes five solute-column interactions that together determine solute retention and column selectivity: hydrophobic, steric, hydrogen bonding of an acceptor solute (i.e., a hydrogen-bond base) by a stationary-phase donor group (i.e., a silanol), hydrogen bonding of a donor solute (e.g., a carboxylic acid) by a stationary-phase acceptor group, and ionic. Of these five interactions, hydrogen bonding between donor solutes (acids) and stationary-phase acceptor groups is the least well understood; the present study aims at resolving this uncertainty, so far as possible. Previous work suggests that there are three distinct stationary-phase sites for hydrogen-bond interaction with carboxylic acids, which we will refer to as column basicity I, II, and III. All RPC columns exhibit a selective retention of carboxylic acids (column basicity I) in varying degree. This now appears to involve an interaction of the solute with a pair of vicinal silanols in the stationary phase. For some type-A columns, an additional basic site (column basicity II) is similar to that for column basicity I in primarily affecting the retention of carboxylic acids. The latter site appears to be associated with metal contamination of the silica. Finally, for embedded-polar-group (EPG) columns, the polar group can serve as a proton acceptor (column basicity III) for acids, phenols, and other donor solutes. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. The effects of Earth's magnetic field on 3-inch diameter photomultipliers used in KM3NeT neutrino telescope

    Science.gov (United States)

    Giordano, V.; Aiello, S.; Leonora, E.; Randazzo, N.

    2016-04-01

    The KM3NeT neutrino telescope will be the largest underwater neutrino telescope and will be located in the abyss of the Mediterranean Sea. In neutrino telescopes the key element of the detector is the optical module and for KM3NeT it consists of 31 PMTs stored inside a transparent pressure-resistant glass sphere of 17-inch that serves as mechanical protection while ensuring good light transmission. Since the PMTs installed into an underwater neutrino telescope can change their orientation because of movements of the detector structure due to sea currents, the influence of Earth's magnetic field has been investigated. Magnetic shielding by means of a mu-metal cage is used to reduce magnetic effects and to make the response of the PMT sufficiently orientation independent. In order to quantify the effect on magnetic field, we compared measurements on variation of gain, transit time spread and detection efficiency for a 3-inch PMT in shielded and unshielded condition at 3 PMT inclinations. Data shows that variations are sufficiently low especially for timing properties.

  16. Application of Derrick Corporation's stack sizer technology for slimes reduction in 6 inch clean coal hydrocyclone circuits

    Energy Technology Data Exchange (ETDEWEB)

    Brodzik, P.

    2009-04-15

    The article discusses the successful introduction of Derrick Corporation's Stack Sizer technology for removing minus 200 mesh slimes from 6-inch coal hydrocyclone underflow prior to froth flotation or dewatering by screen bowl centrifuges. In 2006, the James River Coal Company selected the Stack Sizer fitted with Derrick 150 micron and 100 micron urethane screen panels for removal of the minus 100 mesh high ash clay fraction from the clean coal spiral product circuits. After this application proved successful, Derrick Corporation introduced new 75 micron urethane screen panels for use on the Stack Sizer. Evaluation of feed slurry to flotation cells and screen bowl centrifuges showed significant amounts of minus 75 micron that could potentially be removed by efficient screening technology. Removal of the minus 75 micron fraction was sought to reduce ash and moisture content of the final clean coal product. Full-scale lab tests confirmed that the Stack Sizer fitted with Derrick 75 micron urethane screen panels consistently reduced the minus 75 micron percentage in coal slurry from 6-inch clean coal hydrocyclone underflow that is approximately 15 to 20% solid by-weight and 30 to 60% minus 75 micron to a clean coal fraction that is approximately 13 to 16% minus 75 micron. As a result total ash is reduced from approximately 36 to 38% in the hydrocyclone underflow to 14 to 16% in the oversize product fraction form the Stack Sizers. 1 fig., 2 tabs., 5 photos.

  17. Experimental Investigation of Project Orion Crew Exploration Vehicle Aeroheating: LaRC 20-Inch Mach 6 Air Tunnel Test 6931

    Science.gov (United States)

    Hollis, Brian R.

    2009-01-01

    An investigation of the aeroheating environment of the Project Orion Crew Entry Vehicle has been performed in the Langley Research Center 20-Inch Mach 6 Air Tunnel. Data were measured on a approx.3.5% scale model (0.1778-m/7-inch diameter) of the vehicle using coaxial thermocouples at free stream Reynolds numbers of 2.0 10(exp 6)/ft to 7.30 10(exp 6)/ft and computational predictions were generated for all test conditions. The primary goals of this test were to obtain convective heating data for use in assessing the accuracy of the computational technique and to validate test methodology and heating data from a test of the same wind tunnel model in the Arnold Engineering Development Center Tunnel 9. Secondary goals were to determine the extent of transitional/turbulent data which could be produced on a CEV model in this facility, either with or without boundary-layer trips, and to demonstrate continuous pitch-sweep operation in this tunnel for heat transfer testing.

  18. A stochastic view on column efficiency.

    Science.gov (United States)

    Gritti, Fabrice

    2018-03-09

    A stochastic model of transcolumn eddy dispersion along packed beds was derived. It was based on the calculation of the mean travel time of a single analyte molecule from one radial position to another. The exchange mechanism between two radial positions was governed by the transverse dispersion of the analyte across the column. The radial velocity distribution was obtained by flow simulations in a focused-ion-beam scanning electron microscopy (FIB-SEM) based 3D reconstruction from a 2.1 mm × 50 mm column packed with 2 μm BEH-C 18 particles. Accordingly, the packed bed was divided into three coaxial and uniform zones: (1) a 1.4 particle diameter wide, ordered, and loose packing at the column wall (velocity u w ), (2) an intermediate 130 μm wide, random, and dense packing (velocity u i ), and (3) the bulk packing in the center of the column (velocity u c ). First, the validity of this proposed stochastic model was tested by adjusting the predicted to the observed reduced van Deemter plots of a 2.1 mm × 50 mm column packed with 2 μm BEH-C 18 fully porous particles (FPPs). An excellent agreement was found for u i  = 0.93u c , a result fully consistent with the FIB-SEM observation (u i  = 0.95u c ). Next, the model was used to measure u i  = 0.94u c for 2.1 mm × 100 mm column packed with 1.6 μm Cortecs-C 18 superficially porous particles (SPPs). The relative velocity bias across columns packed with SPPs is then barely smaller than that observed in columns packed with FPPs (+6% versus + 7%). u w =1.8u i is measured for a 75 μm × 1 m capillary column packed with 2 μm BEH-C 18 particles. Despite this large wall-to-center velocity bias (+80%), the presence of the thin and ordered wall packing layer has no negative impact on the kinetic performance of capillary columns. Finally, the stochastic model of long-range eddy dispersion explains why analytical (2.1-4.6 mm i.d.) and capillary (columns can all be

  19. Vertebral Column Resection for Rigid Spinal Deformity.

    Science.gov (United States)

    Saifi, Comron; Laratta, Joseph L; Petridis, Petros; Shillingford, Jamal N; Lehman, Ronald A; Lenke, Lawrence G

    2017-05-01

    Broad narrative review. To review the evolution, operative technique, outcomes, and complications associated with posterior vertebral column resection. A literature review of posterior vertebral column resection was performed. The authors' surgical technique is outlined in detail. The authors' experience and the literature regarding vertebral column resection are discussed at length. Treatment of severe, rigid coronal and/or sagittal malalignment with posterior vertebral column resection results in approximately 50-70% correction depending on the type of deformity. Surgical site infection rates range from 2.9% to 9.7%. Transient and permanent neurologic injury rates range from 0% to 13.8% and 0% to 6.3%, respectively. Although there are significant variations in EBL throughout the literature, it can be minimized by utilizing tranexamic acid intraoperatively. The ability to correct a rigid deformity in the spine relies on osteotomies. Each osteotomy is associated with a particular magnitude of correction at a single level. Posterior vertebral column resection is the most powerful posterior osteotomy method providing a successful correction of fixed complex deformities. Despite meticulous surgical technique and precision, this robust osteotomy technique can be associated with significant morbidity even in the most experienced hands.

  20. Parametric resonance in concrete beam-columns

    Directory of Open Access Journals (Sweden)

    Mamta R. Sharma

    Full Text Available A dynamic instability, called parametric resonance, is exhibited by undampedelastic beam-columns when under the action of pulsating axial force. The scope of the existing theory of parametric resonance is restricted to physically linear beam-columns undergoing finite lateral displacements. In this Paper, the dynamic behaviour of physically nonlinear elastic cracked concrete beam-columns under pulsating axial force and constant lateral force is investigated. The constitutive equations derived earlier by Authors in the form of force-displacement relations are employed here to formulate equations of motion of the SDOF cantilever with mass lumped at its free end. The expected phenomenon of parametric resonance is exhibited in the form of regular subharmonic resonance at about the frequency ratio of two. Resonance peaks broaden with increase in pulsating force. Like damping, physical nonlinearity is also predicted to stabilize the dynamic response at resonance frequencies. In some particular statically unstable conditions, the loss of dynamic stability is shown to occur by divergence. Unexpectedly, similar phenomenon of parametric resonance is exhibited by these physically nonlinear beam-columns undergoing even small lateral displacements. The contribution made to the theory of parametric resonance and the potential relevance of the proposed theory to design of concrete beam-columns is discussed.

  1. Bioremediation of PAH polluted soils: column studies

    Energy Technology Data Exchange (ETDEWEB)

    Hallberg, R.O. [Dept. of Geology and Geochemistry, Stockholm Univ., Stockholm (Sweden); Trepte, B.S. [Angpannefoereningen AB, Stockholm (Sweden)

    2003-07-01

    Background. Due to spills, discharges and leakage, the gaswork site at Husarviken in Stockholm is today the largest (36 ha) creosote-contaminated site in Sweden. The main pollutants are creosote, lead and mercury. The remediation costs are estimated to be as high as US $125 million. It is thus of great interest to find more cost effective remediation methods. Objectives. The aim of this study was to investigate i) if the addition of NTA, EDTA, nitrate, iron and dry yeast would enhance the bioremediation rate of a complex organic pollutant like PAH and, if so, at what concentrations they would be most efficient, ii) the effect on PAH reduction when larger dimensions of the column is used to diminish the effect of water passing along the sides of the column, iii) long-term effects on the reduction of PAH in field-contaminated soil with high concentrations. Materials and Methods. Creosote-contaminated soil from the Husarviken gaswork site was treated with aerated water in column experiments at room temperature. Three column experiments were performed in 2 and 100 L of homogenised soil samples percolated by recirculating flushing water. Fluoranthene was analysed as a representative of the overall degradation of PAH in the columns. (orig.)

  2. SET-LRP of the Hydrophobic Biobased Menthyl Acrylate.

    Science.gov (United States)

    Bensabeh, Nabil; Ronda, Joan C; Galià, Marina; Cádiz, Virginia; Lligadas, Gerard; Percec, Virgil

    2018-04-09

    Cu(0) wire-catalyzed single electron transfer-living radical polymerization (SET-LRP) of (-)-menthyl acrylate, a biobased hydrophobic monomer, was investigated at 25 °C in ethanol, isopropanol, ethyl lactate, 2,2,2-trifluoroethanol (TFE), and 2,2,3,3-tetrafluoropropanol (TFP). All solvents are known to promote, in the presence of N ligands, the mechanistically required self-regulated disproportionation of Cu(I)Br into Cu(0) and Cu(II)Br 2 . Both fluorinated alcohols brought out their characteristics of universal SET-LRP solvents and showed the proper polarity balance to mediate an efficient polymerization of this bulky and hydrophobic monomer. Together with the secondary alkyl halide initiator, methyl 2-bromopropionate (MBP), and the tris(2-dimethylaminoethyl)amine (Me 6 -TREN) ligand, TFE and TPF mediated an efficient SET-LRP of MnA at room temperature that proceeds through a self-generated biphasic system. The results presented here demonstrate that Cu(0) wire-catalyzed SET-LRP can be used to target polyMnA with different block lengths and narrow molecular weight distribution at room temperature. Indeed, the use of a combination of techniques that include GPC, 1 H NMR, MALDI-TOF MS performed before and after thioetherification of bromine terminus via "thio-bromo" click chemistry, and in situ reinitiation copolymerization experiments supports the near perfect chain end functionality of the synthesized biobased hydrophobic polymers. These results expand the possibilities of SET-LRP into the area of renewable resources where hydrophobic compounds are widespread.

  3. Modern acrylics for post-embedding immunostaining techniques.

    Science.gov (United States)

    Newman, G R; Hobot, J A

    1987-09-01

    We describe two methods for rapid processing of biological tissues into LR White acrylic plastic. Both methods make use of LR White's compatibility with small amounts of water, enabling non-osmicated tissue to be only partially dehydrated before infiltration with the plastic, a procedure that improves the sensitivity of post-embedding immunocytochemistry. In addition, both methods are designed to reduce the time for which tissue is exposed to the damaging influence of the plastic monomer, which can cause extraction and sudden shrinkage. The tissue example used in the first method is immersion-fixed, surgically removed human pituitary which, by virtue of its thorough fixation, can be processed quickly at 50 degrees C using catalytic polymerization at room temperature. The concentration of the catalyst is critically set to prevent the temperature rising above 60 degrees C in the tissue blocks. Penetration of immunoperoxidase reagents into 330-nm LR White sections is demonstrated and possible modes of action are discussed. When "lightly" fixed tissue is processed as above, serious polymerization artifacts can result from autocatalysis. A second method, based on the first but employing slower polymerization at 0 degrees C, has therefore been developed. The high level of fine structure that can be retained using this method is illustrated by the demonstration of the trans-tubular Golgi in perfusion-fixed kidney of rat. Biotinylated lectin is localized to cells of the kidney proximal tubule with streptavidin-colloidal gold, to illustrate tissue reactivity. In a second example, the structure of the bacterial cell envelope is shown to be similar in appearance after partial dehydration and LR White embedding to that seen after progressive lowering of temperature, dehydration, and Lowicryl embedding.

  4. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  5. Computational analysis of ozonation in bubble columns

    International Nuclear Information System (INIS)

    Quinones-Bolanos, E.; Zhou, H.; Otten, L.

    2002-01-01

    This paper presents a new computational ozonation model based on the principle of computational fluid dynamics along with the kinetics of ozone decay and microbial inactivation to predict the performance of ozone disinfection in fine bubble columns. The model can be represented using a mixture two-phase flow model to simulate the hydrodynamics of the water flow and using two transport equations to track the concentration profiles of ozone and microorganisms along the height of the column, respectively. The applicability of this model was then demonstrated by comparing the simulated ozone concentrations with experimental measurements obtained from a pilot scale fine bubble column. One distinct advantage of this approach is that it does not require the prerequisite assumptions such as plug flow condition, perfect mixing, tanks-in-series, uniform radial or longitudinal dispersion in predicting the performance of disinfection contactors without carrying out expensive and tedious tracer studies. (author)

  6. Flooding characteristics in pulsed packed extraction columns

    Directory of Open Access Journals (Sweden)

    M. Asadollahzadeh

    2011-12-01

    Full Text Available Flooding behavior of a 76.2 mm diameter pulsed packed column has been determined using four different liquid-liquid systems. The effects of pulsation intensity, flow ratio, interfacial tension, and packing geometry on flood point have been investigated. The results showed that the maximum throughput of the column decreases with an increase in pulsation intensity and flow ratio, while it increases with an increase in interfacial tension. The applicability of the characteristic velocity method to this type of column for the analysis of the flood point was examined and a marked deviation was observed between experimental results and values calculated by this method. Two new empirical correlations for flooding velocity and holdup at flooding are derived in terms of operating variables, packing characteristics, and physical properties of the liquid systems. Good agreement between prediction and experiments has been found for all operating conditions that were investigated.

  7. Mathematical modeling of alcohol distillation columns

    Directory of Open Access Journals (Sweden)

    Ones Osney Pérez

    2011-04-01

    Full Text Available New evaluation modules are proposed to extend the scope of a modular simulator oriented to the sugar cane industry, called STA 4.0, in a way that it can be used to carry out x calculation and analysis in ethanol distilleries. Calculation modules were developed for the simulation of the columns that are combined in the distillation area. Mathematical models were supported on materials and energy balances, equilibrium relations and thermodynamic properties of the ethanol-water system. Ponchon-Savarit method was used for the evaluation of the theoretical stages in the columns. A comparison between the results using Ponchon- Savarit method and those obtained applying McCabe-Thiele method was done for a distillation column. These calculation modules for ethanol distilleries were applied to a real case for validation.

  8. Environmental Impacts on the Strength Parameters of Mineral-Acrylic (PMMA/ATH Facade Panels

    Directory of Open Access Journals (Sweden)

    Aleksander Byrdy

    2015-01-01

    Full Text Available Composite mineral-acrylic panels consist in 80% of natural minerals produced from bauxite (aluminium hydroxides (ATH and in 20% from acrylic resin (polymethyl methacrylate (PMMA. This material due to high usability is widely used in interior finishes. Recently, the mineral-acrylic panels have been used as external claddings of buildings. So far, there are several dozen elevations realized worldwide. Due to the variability of the strength parameters of PMMA acrylic resins depending on the environmental influence, a number of tests on samples of mineral-acrylic panels to verify their suitability for use in climate conditions in Central Europe were performed. The studies determined the change of the material parameters after being subjected to aging process in conditions of high temperature, high relative humidity, freeze-thaw cycles, and UV radiation. In the studies parameters such as flexural strength and modulus of elasticity were measured at a reference temperature of 23°C. In raised and lowered temperatures only the tensile strength tests were conducted. Due to the lack of information in the available literature, the authors carried out tests of the temperature influence on the PMMA/ATH composite modulus of elasticity and flexural strength which is crucial in designing process.

  9. Direct Synthesis of Hyperbranched Poly(acrylic acid-co-3-hydroxypropionate

    Directory of Open Access Journals (Sweden)

    Efkan Çatıker

    2015-01-01

    Full Text Available Hyperbranched poly(acrylic acid-co-3-hydroxypropionate (PAcHP was synthesized by base-catalyzed hydrogen transfer polymerization of acrylic acid through one step. The copolymers obtained through solution and bulk polymerization were insoluble in water and all organic solvents tried. Structural and compositional characterizations of hyperbranched PAcHP were performed by using FTIR, solid 13C-NMR, TGA, and titrimetric analysis. Acrylate fraction of the hyperbranched PAcHP obtained via bulk polymerization was determined as 60–65% by comparing TGA curves of hyperbranched PAcHP and pure poly(3-hydroxy propionate (PHP. However, analytical titration of the same sample revealed that acrylic acid units were about 47.3%. The results obtained from TGA and analytical titration were used to evaluate the chemical structure of the copolymer. Hyperbranched PAcHP exhibited hydrogel properties. Swelling behavior of the copolymer was investigated at a wide pH range and ionic strength. The dynamic swelling profiles of hyperbranched PAcHP exhibited a fast swelling behavior in the first hour and achieved the equilibrium state within 12 h in PBS. Depending on the conditions, the copolymers exhibited swelling ratios up to 2100%. As the copolymer has easily biodegradable propionate and versatile functional acrylic acid units, it can be used as not only biodegradable material in medical applications but also raw material in personal care commodities.

  10. Comparison of impact strength of acrylic resin reinforced with kevlar and polyethylene fibres.

    Science.gov (United States)

    Kamath, G; Bhargava, K

    2002-01-01

    The present study was done to evaluate the impact strengths of heat-activated acrylic resins reinforced with Kevlar fibres, polyethylene fibres and unreinforced heat activated acrylic resin. Each of three groups had 25 specimens. Brass rods of uniform length of 40 mm and diameter of 8 mm were used to prepare the moulds. A combination of long fibres (40 mm length) and short fibres (6 mm length) were used. The total amount of fibres incorporated was limited to 2% by weight of the resin matrix. Short and long fibres of equal weight were incorporated. The short fibres were mixed with polymer and monomer and packed into the mould, while, the long axis of the specimen, perpendicular to the applied force. The specimens were then processed. Impact strength testing was done on Hounsfield's impact testing machine. Kevlar fibre reinforced heat activated acrylic resin specimens recorded higher mean impact strength of 0.8464 Joules, while polyethylene fibres reinforced heat activated acrylic resin recorded mean impact strength of 0.7596 joules. The unreinforced heat activated acrylic resin recorded mean impact strength of 0.3440 Joules.

  11. Efficacy of antimicrobial photodynamic therapy in the disinfection of acrylic denture surfaces: A systematic review.

    Science.gov (United States)

    Varela Kellesarian, Sergio; Abduljabbar, Tariq; Vohra, Fahim; Malmstrom, Hans; Yunker, Michael; Varela Kellesarian, Tammy; Romanos, Georgios E; Javed, Fawad

    2017-03-01

    The aim of the present systematic review was to assess the efficacy of antimicrobial photodynamic therapy (aPDT) in the disinfection of acrylic denture surfaces. IN order to address the focused question: "Is aPDT more effective in decontaminating denture surfaces compared with traditional denture-disinfection techniques?" an electronic search without time or language restrictions was conducted up to November 2016 in indexed databases using different key words. The exclusion criteria included qualitative and/or quantitative reviews, case reports, case series, commentaries, letters to the editor, interviews, and updates. A total of 14 studies were included and processed for data extraction, out of which 1 study was a randomized clinical trial and 13 studies were performed in vitro. Results from 12 experimental studies reported that aPDT was effective in reducing bacteria and/or yeast cultured in single or multispecies biofilm growth on acrylic resin specimens. One experimental study reported selective microorganism reduction on acrylic resin after aPDT. One clinical randomized control trial reported that aPDT presented similar microorganism reduction compared with oral antifungal medication for the disinfection of denture surfaces. The role of aPDT in the disinfection of acrylic resin surfaces is unclear. From a clinical perspective further randomized control trials are needed to assess the efficacy of aPDT in the disinfection of acrylic resin surfaces. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. In vitro antifungal evaluation of seven different disinfectants on acrylic resins.

    Science.gov (United States)

    Yildirim-Bicer, A Z; Peker, I; Akca, G; Celik, I

    2014-01-01

    The aim of this study was to evaluate alternative methods for the disinfection of denture-based materials. Two different denture-based materials were included in the study. Before microbial test, the surface roughness of the acrylic resins was evaluated. Then, the specimens were divided into 8 experimental groups (n = 10), according to microorganism considered and disinfection methods used. The specimens were contaminated in vitro by standardized suspensions of Candida albicans ATCC#90028 and Candida albicans oral isolate. The following test agents were tested: sodium hypochlorite (NaOCl 1%), microwave (MW) energy, ultraviolet (UV) light, mouthwash containing propolis (MCP), Corega Tabs, 50% and 100% white vinegar. After the disinfection procedure, the number of remaining microbial cells was evaluated in CFU/mL. Kruskal-Wallis, ANOVA, and Dunn's test were used for multiple comparisons. Mann Whitney U test was used to compare the surface roughness. Statistically significant difference (P acrylic resins. The autopolymerised acrylic resin surfaces were rougher than surfaces of heat-cured acrylic resin. The most effective disinfection method was 100% white vinegar for tested microorganisms and both acrylic resins. This study showed that white vinegar 100% was the most effective method for tested microorganisms. This agent is cost-effective and easy to access and thus may be appropriate for household use.

  13. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  14. In Vitro Antifungal Evaluation of Seven Different Disinfectants on Acrylic Resins

    Directory of Open Access Journals (Sweden)

    A. Z. Yildirim-Bicer

    2014-01-01

    Full Text Available Objective. The aim of this study was to evaluate alternative methods for the disinfection of denture-based materials. Material and Methods. Two different denture-based materials were included in the study. Before microbial test, the surface roughness of the acrylic resins was evaluated. Then, the specimens were divided into 8 experimental groups (n=10, according to microorganism considered and disinfection methods used. The specimens were contaminated in vitro by standardized suspensions of Candida albicans ATCC#90028 and Candida albicans oral isolate. The following test agents were tested: sodium hypochlorite (NaOCl 1%, microwave (MW energy, ultraviolet (UV light, mouthwash containing propolis (MCP, Corega Tabs, 50% and 100% white vinegar. After the disinfection procedure, the number of remaining microbial cells was evaluated in CFU/mL. Kruskal-Wallis, ANOVA, and Dunn’s test were used for multiple comparisons. Mann Whitney U test was used to compare the surface roughness. Results. Statistically significant difference (P<0.05 was found between autopolymerised and heat-cured acrylic resins. The autopolymerised acrylic resin surfaces were rougher than surfaces of heat-cured acrylic resin. The most effective disinfection method was 100% white vinegar for tested microorganisms and both acrylic resins. Conclusion. This study showed that white vinegar 100% was the most effective method for tested microorganisms. This agent is cost-effective and easy to access and thus may be appropriate for household use.

  15. The Effect of Storage Environment on Dimensional Changes of Acrylic Resin Post Patterns

    Directory of Open Access Journals (Sweden)

    Abbas Fallahtafti

    2018-03-01

    Full Text Available Introduction: The purpose of this study was to compare dimensional changes of two types of auto polymerizing acrylic resin patterns (APARPs in three different storing environments. Methods: 60 acrylic post and core patterns were made of two types of Duralay acrylic resins (Aria dent, Iran and Reliance, Dental Mfg. Co, USA using a canine model. Then coronal, apical diameter and coronoapical length of patterns were measured. Afterwards, they were divided into two categories of 30 for each type of Duralay acrylic resin type. Each category was divided into three groups of ten randomly to immerse in three storage environments (Deconex®53plus Borer ChemieAG, Switzerland, Unident ® Impre(USF Healthcare S.A, Sweitzerland and water. After one hour, three mentioned values were measured again. Data were analyzed by SPSS20 using t-test, paired t-test and ANOVA. Results: Results showed that there were no statistically difference (p value> 0.05 about all dimensions of auto polymerizing acrylic post and core patterns except apical diameter and coronoapical length of Dental Mfg. Co, USA in Deconex®53 plus. Conclusion: The best environment to store Duralay APARPs with minimal changes was water and for disinfection, Deconex®53plus and Unident ® Imprecan showed acceptable properties with both of Duralay types.

  16. Surface morphology changes of acrylic resins during finishing and polishing phases

    Directory of Open Access Journals (Sweden)

    Glaucio Serra

    2013-12-01

    Full Text Available INTRODUCTION: The finishing and polishing phases are essential to improve smoothness and shining on the surface of acrylic resins used to make removable orthodontic appliances. A good surface finishing reduces roughness, which facilitates hygiene, prevents staining and provides greater comfort to the patients. OBJECTIVE: The aim of this paper was to analyze the changes on surface morphology of acrylic resins during finishing and polishing phases. METHODS: Thirty discs (10 mm in diameter and 5 mm in length were made with acrylic resin and randomly divided into ten groups. The control group did not receive any treatment while the other groups received gradual finishing and polishing. The last group received the entire finishing and polishing procedures. Surface morphology was qualitatively analyzed through scanning electron microscopy and quantitatively analyzed through a laser profilometer test. RESULTS: The acrylic resin surfaces without treatment showed bubbles which were not observed in the subsequent phases. Wearing out with multilaminated burs, finishing with wood sandpaper and finishing with water sandpaper resulted in surfaces with decreasing irregularities. The surfaces that were polished with pumice and with low abrasive liquids showed high superficial smoothness. CONCLUSION: Highly smooth acrylic resin surfaces can be obtained after mechanical finishing and polishing performed with multilaminated burs, wood sandpaper, water sandpaper, pumice and low abrasive liquids.

  17. Operation of the annular pulsed column, (2)

    International Nuclear Information System (INIS)

    Takahashi, Keiki; Tsukada, Takeshi

    1988-01-01

    The heat of reaction generated form the uranium extraction is considered to from the temperature profile inside the pulsed column. A simulation code was developed to estimate the temperature profile, considering heat generation and counter-current heat transfer. The temperature profiles calculated using this code was found to depend on both the position of the extraction zone and the operating condition. The reported experimental result was fairly represented by this simulation code. We consider that this presented simulation code is capable of providing with the temperature profile in the pulsed column and useful for the monitoring of the uranium extraction zone. (author)

  18. Distillation columns inspection through gamma scanning

    International Nuclear Information System (INIS)

    Garcia, Marco

    1999-09-01

    The application of nuclear energy is very wide and it allows the saving of economic resources since the investigation of a certain process is carried out without stop the plant. The gamma scanning of oil c racking c olumns are practical examples, they allow to determine the hydraulic operation of the inspected columns. A source of Co-60 22mCi and a detector with a crystal of INa(TI) are used. This paper shows the results got from a profile carried out in a column distillation

  19. Performance of RC columns with partial length corrosion

    International Nuclear Information System (INIS)

    Wang Xiaohui; Liang Fayun

    2008-01-01

    Experimental and analytical studies on the load capacity of reinforced concrete (RC) columns with partial length corrosion are presented, where only a fraction of the column length was corroded. Twelve simply supported columns were eccentrically loaded. The primary variables were partial length corrosion in tensile or compressive zone and the corrosion level within this length. The failure of the corroded column occurs in the partial length, mainly developed from or located nearby or merged with the longitudinal corrosion cracks. For RC column with large eccentricity, load capacity of the column is mainly influenced by the partial length corrosion in tensile zone; while for RC column with small eccentricity, load capacity of the column greatly decreases due to the partial length corrosion in compressive zone. The destruction of the longitudinally mechanical integrality of the column in the partial length leads to this great reduction of the load capacity of the RC column

  20. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  1. Convolutional Codes with Maximum Column Sum Rank for Network Streaming

    OpenAIRE

    Mahmood, Rafid; Badr, Ahmed; Khisti, Ashish

    2015-01-01

    The column Hamming distance of a convolutional code determines the error correction capability when streaming over a class of packet erasure channels. We introduce a metric known as the column sum rank, that parallels column Hamming distance when streaming over a network with link failures. We prove rank analogues of several known column Hamming distance properties and introduce a new family of convolutional codes that maximize the column sum rank up to the code memory. Our construction invol...

  2. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    Science.gov (United States)

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  3. Synthesis of acrylic and allylic bifunctional cross-linking monomers derived from PET waste

    International Nuclear Information System (INIS)

    Cruz-Aguilar, A; Herrera-González, A M; Vázquez-García, R A; Coreño, J; Navarro-Rodríguez, D

    2013-01-01

    An acrylic and two novel allylic monomers synthesized from bis (hydroxyethyl) terephthalate, BHET, are reported. This was obtained by glycolysis of post-consumer PET with boiling ethylene glycol. The bifunctional monomer bis(2-(acryloyloxy)ethyl) terephthalate was obtained from acryloyl chloride, while the allylic monomers 2-(((allyloxi)carbonyl)oxy) ethyl (2-hydroxyethyl) terephthalate and bis(2-(((allyloxi)carbonyl)oxy)ethyl) terephthalate, from allyl chloroformate. Cross-linking was studied in bulk polymerization using two different thermal initiators. Monomers were analyzed by means of 1 H NMR and the cross-linked polymers by infrared spectroscopy. Gel content higher than 90% was obtained for the acrylic monomer. In the case of the mixture of the allylic monomers, the cross-linked polymer was 80 % using BPO initiator, being this mixture 24 times less reactive than the acrylic monomer.

  4. Catalytic production of methyl acrylates by gold-mediated cross coupling of unsaturated aldehydes with methanol

    Science.gov (United States)

    Karakalos, Stavros; Zugic, Branko; Stowers, Kara J.; Biener, Monika M.; Biener, Juergen; Friend, Cynthia M.; Madix, Robert J.

    2016-10-01

    Modern methods of esterification, one of the most important reactions in organic synthesis, are reaching their limits, as far as waste and expense are concerned. Novel chemical approaches to ester formation are therefore of importance. Here we report a simple procedure free of caustic reagents or byproducts for the facile direct oxidative methyl esterification of aldehydes over nanoporous Au catalysts. Complementary model studies on single crystal gold surfaces establish the fundamental reactions involved. We find that methanol more readily reacts with adsorbed active oxygen than do the aldehydes, but that once the aldehydes do react, they form strongly-bound acrylates that block reactive sites and decrease the yields of acrylic esters under steady flow conditions at 420 K. Significant improvements in yield can be achieved by operating at higher temperatures, which render the site-blocking acrylates unstable.

  5. Preparation and characteristics of acrylic acid/styrene composite plasma polymerized membranes

    Science.gov (United States)

    Jiang, Zhongqing; Jiang, Zhong-jie; Shi, Yicai; Meng, Yuedong

    2010-08-01

    Plasma polymerization has gained increasing interest for the deposition of functional plasma-polymerized membranes suitable for a wide range of applications on account of its advantageous features. In this work, acrylic acid/styrene composite plasma polymerized membranes were synthesized by plasma polymerization of a mixture of acrylic acid and styrene monomers in a low-frequency after-glow capacitively coupled plasma (CCP) discharge process. The structure and composition of the plasma polymerized membranes were characterized by Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). The results showed that the partial pressure ratio between acrylic acid (AA) and styrene (St), applied discharge power and the energy of the extracted particles have considerable effects on the structure and the content of functional groups of the deposited membranes.

  6. Applications of Blue Light-curing Acrylic Resin to Forensic Sample Preparation and Microtomy.

    Science.gov (United States)

    Groves, Ethan; Palenik, Christopher S

    2016-03-01

    This study discusses the results of an evaluation of a one-part blue light-curing acrylic resin for embedding trace evidence prior to the preparation of thin sections with a microtome. Through a comparison to several epoxy resins, the physical properties relevant to both trace evidence examination and analytical microscopy in general, including as viscosity, clarity, color, hardness, and cure speed, were explored. Finally, thin sections from paint samples embedded in this acrylic resin were evaluated to determine if, through smearing or impregnation, the resin contributed to the infrared spectra. The results of this study show that blue light-curing acrylic resins provide the desired properties of an embedding medium, generate high-quality thin sections, and can significantly simplify the preparation of paint chips, fibers and a multitude of other types of microscopic samples in the forensic trace evidence laboratory. © 2015 American Academy of Forensic Sciences.

  7. Synthesis of acrylated palm oil nanoparticles using microemulsion polymerization initiated by gamma ray

    International Nuclear Information System (INIS)

    Rida Tajau; Wan Md Zin Wan Yunus; Khairul Zaman Mohd Dahlan; Mohd Hilmi Mahmood; Kamaruddin Hashim; Sim, Flora; Sharila Muhd Faizal

    2010-01-01

    The use of microemulsion in the development of nanoparticle based on acrylated palm oil product is demonstrated. The microemulsion polymerization was initiated by gamma ray for synthesizing crosslinked nanoparticle. Polymerization of acrylated palm oil in three-component ionic microemulsions was prepared with sodium dodecyl sulphate (SDS) and water. The resulted nanoparticle, before and after initiated by gamma ray, were evaluated in terms of particle diameter, surface charge and molecular structure. Type and concentration of surfactants, monomer concentration, radiation dose and time of storage strongly affected the size, charge and size stability of the particles. For the development of new microscopic polymer acrylated palm oil can be synthesized into nano sized particle and it has potential to be developed in medical devices and controlled-drug-release-applications. (author)

  8. APPLICATION OF DIRECT CONTACT TEST IN EVALUATION OF CYTOTOXICITY OF ACRYLIC DENTURE BASE RESINS

    Directory of Open Access Journals (Sweden)

    Milena Kostić

    2012-03-01

    Full Text Available The use of acrylic denture base resins is widely spread in dental practice. They belong to the group of biomaterials due to their role of morphological and functional substituent in the mouth. However, clinical practice has shown that some toxic ingredients of these materials may lead to adverse local and even systemic changes. The aim of the study was to evaluate cytotoxic effect of various denture base resins on cell culture using direct contact test. The effect of four different acrylic materials on HeLa cell structure was evaluated. Upon light microscopy analysis, MTT test was performed without previous removal of material samples. The obtained values of MTT indicate that cell proliferation is dependant on the type of acrylic denture base resins. Cold polymerization denture base resins showed mild inhibitory effect on the cell culture growth. The signs of toxicity were not observed in heat polymerization denture base resins.

  9. Influence of pressure on the properties of chromatographic columns. II. The column hold-up volume.

    Science.gov (United States)

    Gritti, Fabrice; Martin, Michel; Guiochon, Georges

    2005-04-08

    The effect of the local pressure and of the average column pressure on the hold-up column volume was investigated between 1 and 400 bar, from a theoretical and an experimental point of view. Calculations based upon the elasticity of the solids involved (column wall and packing material) and the compressibility of the liquid phase show that the increase of the column hold-up volume with increasing pressure that is observed is correlated with (in order of decreasing importance): (1) the compressibility of the mobile phase (+1 to 5%); (2) in RPLC, the compressibility of the C18-bonded layer on the surface of the silica (+0.5 to 1%); and (3) the expansion of the column tube (columns packed with the pure Resolve silica (0% carbon), the derivatized Resolve-C18 (10% carbon) and the Symmetry-C18 (20% carbon) adsorbents, using water, methanol, or n-pentane as the mobile phase. These solvents have different compressibilities. However, 1% of the relative increase of the column hold-up volume that was observed when the pressure was raised is not accounted for by the compressibilities of either the solvent or the C18-bonded phase. It is due to the influence of the pressure on the retention behavior of thiourea, the compound used as tracer to measure the hold-up volume.

  10. Characterization of the first double-sided 3D radiation sensors fabricated at FBK on 6-inch silicon wafers

    International Nuclear Information System (INIS)

    Sultan, D.M.S.; Mendicino, R.; Betta, G.-F. Dalla; Boscardin, M.; Ronchin, S.; Zorzi, N.

    2015-01-01

    Following 3D pixel sensor production for the ATLAS Insertable B-Layer, Fondazione Bruno Kessler (FBK) fabrication facility has recently been upgraded to process 6-inch wafers. In 2014, a test batch was fabricated to check for possible issues relevant to this upgrade. While maintaining a double-sided fabrication technology, some process modifications have been investigated. We report here on the technology and the design of this batch, and present selected results from the electrical characterization of sensors and test structures. Notably, the breakdown voltage is shown to exceed 200 V before irradiation, much higher than in earlier productions, demonstrating robustness in terms of radiation hardness for forthcoming productions aimed at High Luminosity LHC upgrades

  11. Two inch large area patterning on a vertical light-emitting diode by nano-imprinting technology

    International Nuclear Information System (INIS)

    Byeon, Kyeong-Jae; Hong, Eun-Ju; Park, Hyoungwon; Yoon, Kyung-Min; Lee, Heon; Song, Hyun Don; Lee, Jin Wook; Kim, Sun-Kyung; Cho, Hyun Kyong; Kwon, Ho Ki

    2010-01-01

    A vertical light-emitting diode (LED) with a chip size of 500 × 500 µm 2 was fabricated by the laser lift-off (LLO) process of an InGaN-based blue LED wafer. After the LLO process, photonic crystal patterns by UV nano-imprint lithography were formed on the n-GaN top layer of the vertical LED over the entire area with a diameter of 2 inches. As the result of n-GaN patterning, light output power of the vertical LED with photonic crystals was increased by up to 44% compared to that of the vertical LED without a photonic crystal at a driving current of 1000 mA

  12. Direct initiation of the photopolymerization of acrylates by 222 nm excimer UV radiation

    International Nuclear Information System (INIS)

    Knolle, W.; Scherzer, T.; Naumov, S.; Mehnert, R.

    2002-01-01

    Complete text of publication follows. Usually, the photopolymerisation of functionalised monomers and oligomers requires the addition of one or several photoinitiators to the formulation. The light of typically used mercury lamps (1>250 nm) is mainly absorbed by the photoinitiator leading to initiating species (radicals) with a high quantum yield. The introduction of excimer lamps as monochromatic UV sources with an intense short-wavelength emission opens up new possibilities for a photoinitiator-free initiation of the acrylate polymerisation. Like most other organic compounds, acrylates strongly absorb light with a wavelength shorter than about 220 to 240 nm, and they can therefore be directly excited by the 222 nm excimer radiation from a KrCl* lamp. Real-time FTIR-ATR spectroscopy was used to study the reactivity of various neat acrylates. Depending on the absorption coefficient, aliphatic acrylates can be cured up to a thickness of several microns whereas for highly absorbing aromatic acrylates, the depth of cure reaches only some hundred nanometres. Since the radical yield is low, photopolymerisation without photoinitiator has to be performed in an inert atmosphere. Laser photolysis experiments were carried out with a KrCl* excimer laser (pulse width 20 ns, up to 5 mJ per pulse) to investigate the primary processes of the direct initiation. Additionally, quantum chemical calculations were performed to assist the interpretation of the photolysis data. For all acrylates studied, direct excitation at 222 nm first leads to the formation of a triplet state which is highly localized at the vinyl double bond (and not at the carbonyl group). This triplet state may undergo different reactions like inter- and intramolecular hydrogen transfer and biradical formation as well as the addition to a ground state molecule (chain start). Our current interpretation of the experimental results and the quantum chemical calculations will be presented and discussed

  13. Cytotoxicity Evaluation of Two Bis-Acryl Composite Resins Using Human Gingival Fibroblasts.

    Science.gov (United States)

    Gonçalves, Fabiano Palmeira; Alves, Gutemberg; Guimarães, Vladi Oliveira; Gallito, Marco Antônio; Oliveira, Felipe; Scelza, Míriam Zaccaro

    2016-01-01

    Bis-acryl resins are used for temporary dental restorations and have shown advantages over other materials. The aim of this work was to evaluate the in vitro cytotoxicity of two bis-acryl composite resins (Protemp 4 and Luxatemp Star), obtained at 1, 7 and 40 days after mixing the resin components, using a standardized assay employing human primary cells closely related to oral tissues. Human gingival fibroblast cell cultures were exposed for 24 h to either bis-acryl composite resins, polystyrene beads (negative control) and latex (positive control) extracts obtained after incubation by the different periods, at 37 °C under 5% CO2. Cell viability was evaluated using a multiparametric procedure involving sequential assessment (using the same cells) of mitochondrial activity (XTT assay), membrane integrity (neutral red test) and total cell density (crystal violet dye exclusion test). The cells exposed to the resin extracts showed cell viability indexes exceeding 75% after 24 h. Even when cells were exposed to extracts prepared with longer conditioning times, the bis-acryl composite resins showed no significant cytotoxic effects (p>0.05), compared to the control group or in relation to the first 24 h of contact with the products. There were no differences among the results obtained for the bis-acryl composite resins evaluated 24 h, 7 days and 40 days after mixing. It may be concluded that the bis-acryl resins Protemp 4 and Luxatemp Star were cytocompatible with human gingival fibroblasts, suggesting that both materials are suitable for use in contact with human tissues.

  14. High-impact strength acrylic denture base material processed by autoclave.

    Science.gov (United States)

    Abdulwahhab, Salwan Sami

    2013-10-01

    To investigate the effect of two different cycles of autoclave processing on the transverse strength, impact strength, surface hardness and the porosity of high-impact strength acrylic denture base material. High Impact Acryl was the heat-cured acrylic denture base material included in the study. A total of 120 specimens were prepared, the specimens were grouped into: control groups in which high-impact strength acrylic resins processed by conventional water-bath processing technique (74°C for 1.5 h then boil for 30 min) and experimental groups in which high-impact strength acrylic resins processed by autoclave at 121°C, 210 kPa .The experimental groups were divided into (fast) groups for 15 min, and (slow) groups for 30 min. To study the effect of the autoclave processing (Tuttnauer 2540EA), four tests were conducted transverse strength (Instron universal testing machine), impact strength (Charpy tester), surface hardness (shore D), and porosity test. The results were analyzed to ANOVA and LSD test. In ANOVA test, there were highly significant differences between the results of the processing techniques in transverse, impact, hardness, and porosity test. The LSD test showed a significant difference between control and fast groups in transverse and hardness tests and a non-significant difference in impact test and a highly significant difference in porosity test; while, there were a highly significant differences between control and slow groups in all examined tests; finally, there were a non-significant difference between fast and slow groups in transverse and porosity tests and a highly significant difference in impact and hardness tests. In the autoclave processing technique, the slow (long) curing cycle improved the tested physical and mechanical properties as compared with the fast (short) curing cycle. The autoclave processing technique improved the tested physical and mechanical properties of High Impact Acryl. Copyright © 2013 Japan Prosthodontic Society

  15. On Row Rank Equal Column Rank

    Science.gov (United States)

    Khalili, Parviz

    2009-01-01

    We will prove a well-known theorem in Linear Algebra, that is, for any "m x n" matrix the dimension of row space and column space are the same. The proof is based on the subject of "elementary matrices" and "reduced row-echelon" form of a matrix.

  16. On Stability of a Bubble Column

    Czech Academy of Sciences Publication Activity Database

    Růžička, Marek

    2013-01-01

    Roč. 91, č. 2 (2013), s. 191-203 ISSN 0263-8762 R&D Projects: GA ČR GA104/07/1110 Institutional support: RVO:67985858 Keywords : bubble column * flow regimes * steady solution Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.281, year: 2013

  17. Flexural buckling of fire exposed aluminium columns

    NARCIS (Netherlands)

    Maljaars, J.; Twilt, L.; Soetens, F.

    2009-01-01

    In order to study buckling of fire exposed aluminium columns, a finite element model is developed. The results of this model are verified with experiments. Based on a parametric study with the finite element model, it is concluded that the simple calculation model for flexural buckling of fire

  18. Chief Editor's column/Science Smiles

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 4. Chief Editor's column / Science Smiles. R K Laxman. Science Smiles Volume 1 Issue 4 April 1996 pp 4-4. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/001/04/0004-0004. Author Affiliations.

  19. Column Stores as an IR Prototyping Tool

    NARCIS (Netherlands)

    H.F. Mühleisen (Hannes); T. Samar (Thaer); J.J.P. Lin (Jimmy); A.P. de Vries (Arjen)

    2014-01-01

    textabstract. We make the suggestion that instead of implementing custom index structures and query evaluation algorithms, IR researchers should simply store document representations in a column-oriented relational database and write ranking models using SQL. For rapid prototyping, this is

  20. Robust Geometric Control of a Distillation Column

    DEFF Research Database (Denmark)

    Kymmel, Mogens; Andersen, Henrik Weisberg

    1987-01-01

    A frequency domain method, which makes it possible to adjust multivariable controllers with respect to both nominal performance and robustness, is presented. The basic idea in the approach is that the designer assigns objectives such as steady-state tracking, maximum resonance peaks, bandwidth, m...... is used to examine and improve geometric control of a binary distillation column....

  1. Yield stress independent column buckling curves

    DEFF Research Database (Denmark)

    Stan, Tudor‐Cristian; Jönsson, Jeppe

    2017-01-01

    Using GMNIA and shell finite element modelling of steel columns it is ascertained that the buckling curves for given imperfections and residual stresses are not only dependent on the relative slenderness ratio and the cross section shape but also on the magnitude of the yield stress. The influence...

  2. "Dry-column" chromatography of plant pigments

    Science.gov (United States)

    Woeller, F. H.; Lehwalt, M. F.; Oyama, V. I.

    1973-01-01

    Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

  3. Seismic Behaviour of Synthetic-Frc Columns

    Science.gov (United States)

    Paultre, P.; Eid, R.

    2017-09-01

    Inclusion of short discrete fibres into the concrete mixture can increase the compressive strength and ductility of normal-strength concrete (NSC) and high-strength concrete (HSC) column specimens under compressive loading as already has been shown by several studies. Concrete design codes ensure ductile behaviour of columns by setting a requirement for a minimum amount of transverse steel reinforcement. Therefore, the inclusion of discrete short fibres into the concrete mixture combined with a reduced amount of lateral reinforcement can be an alternative to the latter full amount required by the codes. This paper presents tests that were performed on large-scale fibre-reinforced NSC circular columns under cyclic flexure and constant axial load simulating earthquake loading. The aim of this test program is to examine the combined confinement effect of steel or synthetic fibres and the transverse steel reinforcement type (spirals or hoops) on the structural performance of RC columns. The results show that in terms of ductility and energy dissipation, the behaviour of the fibre-reinforced concrete (FRC) specimens is improved compared to the nonfibrous ones. This behaviour is also predicted by the proposed confinement model which takes into account the mechanical and the geometrical properties of the concrete and the reinforcement as well as those of the fibres.

  4. Contexts for Column Addition and Subtraction

    Science.gov (United States)

    Lopez Fernandez, Jorge M.; Velazquez Estrella, Aileen

    2011-01-01

    In this article, the authors discuss their approach to column addition and subtraction algorithms. Adapting an original idea of Paul Cobb and Erna Yackel's from "A Contextual Investigation of Three-Digit Addition and Subtraction" related to packing and unpacking candy in a candy factory, the authors provided an analogous context by…

  5. The hydrodynamic behaviour of a pulsed column

    International Nuclear Information System (INIS)

    Vassallo, Gary.

    1983-01-01

    Holdup, droplet size and continuous-phase backmixing were measured in a 72 mm i.d. pulsed perforated-plate column. The contactor was operated using the system 2 M HNO 3 -30% TBP/OP. Pulse amplitude, frequency and both phase flow rates were varied over a wide range of values although the column was maintained in the continuous dispersion region. Dispersed-phase holdup appeared to pass through a minimum at a constant pulse velocity corresponding to the onset of continuous dispersion type operation. The value of this minimum varied linearly with the dispersed-phase flow rate. Measurements of holdup were correlated using the slip velocity concept, modified to allow for droplet coalescence. Values of the Sauter-mean droplet diameter were found to vary with the pulse velocity and holdup. It was shown that the ratio of the characteristic droplet velocity in a pulsed perforated-plate column to that in a spray column as derived from the correlation of Hu and Kintner is a function of the pulse velocity and holdup. This led to an expression which correlated the droplet size data with negligible error. Continuous-phase back mixing was found to increase with amplitude; frequency and dispersed-phase flow rate. The effect of the continuous-phase flow rate was variable. At low values, increasing the phase velocity reduced back mixing while at high values, an increase in the phase velocity had the reverse effect

  6. Maxillary zirconia implant fixed partial dentures opposing an acrylic resin implant fixed complete denture: a two-year clinical report.

    Science.gov (United States)

    Chang, Paul P; Henegbarth, Ernst A; Lang, Lisa A

    2007-06-01

    The fabrication of fixed implant-supported prostheses for edentulous patients may be performed using all-ceramic or acrylic resin materials. This clinical report describes the fabrication and 2-year follow-up of maxillary zirconia implant fixed partial dentures opposing a mandibular acrylic resin screw-retained fixed complete denture.

  7. Electroactive behavior assessment of poly(acrylic acid)-graphene oxide composite hydrogel in the detection of cadmium

    NARCIS (Netherlands)

    Bejarano-Jimenez, A.; Escobar-Barrios, V.A.; Kleijn, J.M.; Oritz-Ledon, C.A.; Chazaro-Ruiz, L.F.

    2014-01-01

    Super absorbent polymers of acrylic acid-graphene oxide (PAA-GO) were synthesized with different percentage of chemical neutralization (0, 10, and 20%) of the acrylic acid monomer before its polymerization. The influence of their swelling and adsorption/desorption capacity of cadmium ions in aqueous

  8. The influence of ultrasound on the release of gentamicin from antibiotic-loaded acrylic beads and bone cements

    NARCIS (Netherlands)

    Ensing, GT; Hendriks, JGE; Jongsma, JE; van Horn, [No Value; van der Mei, HC; Busscher, HJ

    2005-01-01

    Gentamicin-loaded acrylic beads are loosely placed in infected bone cavities, whereas gentamicin-loaded acrylic bone cement is used as a mechanical filler in bone to anchor prosthetic components. Both drug delivery systems are used to decrease infection rates by gentamicin release. The objective of

  9. A comparative Study of the Masticatory Efficiency in Complete Dentures Using Acrylic and Metal Occlusal Posterior Teeth-Photocolorimetric Analysis.

    Science.gov (United States)

    Awinashe, Vaibhav N; Nagda, Suhasini J

    2010-06-01

    Masticatory efficiency is always compromised in complete denture patients. The denture teeth with compromised occlusal anatomy and material further compound the inherent limitations of complete dentures. To compare the masticatory efficiency of patients with complete denture using acrylic and metal occlusal posterior teeth. Ten edentulous patients with well-formed ridges were selected. Complete dentures using acrylic and metal occlusal posterior teeth were fabricated. The masticatory efficiency was calculated using photo colorimeter. Complete dentures with 20° acrylic resin posterior teeth were fabricated for ten edentulous patients and masticatory efficiency was measured using raw beetroot as test food on a photocolorimeter after 10, 15, 20 strokes. The acrylic resin posterior teeth were replaced with metal occlusal posterior teeth on the same denture base. The masticatory efficiency was measured by the same method. The mean average percentage of masticatory efficiency with acrylic resin teeth and metal occlusal teeth were first calculated and statistical analysis was done using students unpaired t test. The average masticatory efficiency with acrylic teeth was 46.46% and metal occlusal teeth was 65.62, 't' = 5.38. The difference between the mean average masticatory performance percentage with acrylic teeth and metal occlusal teeth was significant at 1% i.e. P acrylic teeth without any alteration in position or relation.

  10. The development of 8 inch roll-to-plate nanoimprint lithography (8-R2P-NIL) system

    Science.gov (United States)

    Lee, Lai Seng; Mohamed, Khairudin; Ooi, Su Guan

    2017-07-01

    Growth in semiconductor and integrated circuit industry was observed in the past decennium of years for industrial technology which followed Moore's law. The line width of nanostructure to be exposed was influenced by the essential technology of photolithography. Thus, it is crucial to have a low cost and high throughput manufacturing process for nanostructures. Nanoimprint Lithography technique invented by Stephen Y. Chou was considered as major nanolithography process to be used in future integrated circuit and integrated optics. The drawbacks of high imprint pressure, high imprint temperature, air bubbles formation, resist sticking to mold and low throughput of thermal nanoimprint lithography on silicon wafer have yet to be solved. Thus, the objectives of this work is to develop a high throughput, low imprint force, room temperature UV assisted 8 inch roll to plate nanoimprint lithography system capable of imprinting nanostructures on 200 mm silicon wafer using roller imprint with flexible mold. A piece of resist spin coated silicon wafer was placed onto vacuum chuck drives forward by a stepper motor. A quartz roller wrapped with a piece of transparent flexible mold was used as imprint roller. The imprinted nanostructures were cured by 10 W, 365 nm UV LED which situated inside the quartz roller. Heat generated by UV LED was dissipated by micro heat pipe. The flexible mold detaches from imprinted nanostructures in a 'line peeling' pattern and imprint pressure was measured by ultra-thin force sensors. This system has imprinting speed capability ranging from 0.19 mm/s to 5.65 mm/s, equivalent to imprinting capability of 3 to 20 pieces of 8 inch wafers per hour. Speed synchronization between imprint roller and vacuum chuck was achieved by controlling pulse rate supplied to stepper motor which drive the vacuum chuck. The speed different ranging from 2 nm/s to 98 nm/s is achievable. Vacuum chuck height was controlled by stepper motor with displacement of 5 nm/step.

  11. Designing ultraviolet curing of multifunctional (meth)acrylate hard coats

    Science.gov (United States)

    Wen, Mei

    Ultraviolet (UV) curing rapidly converts multifunctional (meth)acrylate liquid monomers into highly cross-linked, impervious, hard polymeric coatings at ambient temperature. This solidification process occurs by free-radical cross-linking polymerization. To achieve a better design of this process, it is desirable to have high conversion of functional groups, low stress, adequate mechanical properties, and low costs. To approach this design goal, the following modeling and experimental work was carried out. Firstly, a kinetic model was developed to simulate radical trapping. This model predicts a peak in the concentration of active radicals and a monotonic rise of the concentration of trapped radicals during polymerization. It also predicts a decrease in the fraction of trapped radicals at a given conversion as the UV light intensity is raised. Secondly, a kinetic gelation model, in which reaction occurs locally on a lattice, was developed. Unlike previous such models, this model accounts for free radical reaction time more accurately. It was found that a more uniform distribution of reacted sites leads to a favored propagation at a given conversion. Moreover, radical trapping and termination were found to shorten the kinetic chain length and to lower the asymptotic conversion reached when initiators are exhausted. Thirdly, elastic modulus evolution was simulated with a rigidity percolation model, in which bonds created by free-radical polymerization are represented as rigidly jointed beams. Simulations show that modulus of a network depends on the connectivity between monomer units as well as bonding structure. Finally, experimental determination of volume shrinkage of a sandwiched film was measured with a dynamic mechanical analyzer probe. A faster reaction causes more severely delayed volume shrinkage from the thermodynamic equilibrium volume required by the reaction. Nevertheless, volume shrinks more when the shrinkage of the thermodynamic volume rises. In

  12. Single column and two-column H-D-T distillation experiments at TSTA

    International Nuclear Information System (INIS)

    Yamanishi, T.; Yoshida, H.; Hirata, S.; Naito, T.; Naruse, Y.; Sherman, R.H.; Bartlit, J.R.; Anderson, J.L.

    1988-01-01

    Cryogenic distillation experiments were peformed at TSTA with H-D-T system by using a single column and a two-column cascade. In the single column experiment, fundamental engineering data such as the liquid holdup and the HETP were measured under a variety of operational condtions. The liquid holdup in the packed section was about 10 /approximately/ 15% of its superficial volume. The HETP values were from 4 to 6 cm, and increased slightly with the vapor velocity. The reflux ratio had no effect on the HETP. For the wo-colunn experiemnt, dynamic behavior of the cascade was observed. 8 refs., 7 figs., 2 tabs

  13. Self-Compacting Concrete Incorporating Micro-SiO2 and Acrylic Polymer

    Directory of Open Access Journals (Sweden)

    Ali Heidari

    2014-01-01

    Full Text Available This study examined the effects of using acrylic polymer and micro-SiO2 in self-compacting concrete (SCC. Using these materials in SCC improves the characteristics of the concrete. Self-compacting samples with 1-2% of a polymer and 10% micro-SiO2 were made. In all cases, compressive strength, water absorption, and self-compacting tests were done. The results show that adding acrylic polymer and micro-SiO2 does not have a significant negative effect on the mechanical properties of self-compacting concrete. In addition using these materials leads to improving them.

  14. Antibacterial activity of chitosan and the interpolyelectrolyte complexes of poly(acrylic acid)-chitosan

    OpenAIRE

    Ortega-Ortiz, Hortensia; Gutiérrez-Rodríguez, Baltazar; Cadenas-Pliego, Gregorio; Jimenez, Luis Ibarra

    2010-01-01

    The antimicrobial activity of chitosan and water soluble interpolyelectrolyte complexes of poly(acrylic acid)-chitosan was studied. Chitosans of two different molecular weights were tested at different concentration for 0.5 to 5 g·L-1 as antimicrobial agents against P. aeruginosa and P. oleovorans. In both cases, the best microbial inhibition was obtained with the concentration of 5 g·L-1. However, the interpolyelectrolyte complexes of poly(acrylic acid)-chitosan with composition φ =2 pr...

  15. [Sectional acrylic dentures for a partially edentulous patient with microstomia: a clinical report].

    Science.gov (United States)

    Suzuki, Midori

    2006-01-01

    The patient was a 48-year-old partially edentulous male with microstomia. His chief complaints were masticatory disturbance and aesthetic problems caused by missing teeth. After trayless impressions for diagnostic casts were made, sectional trays and a sectional record block were used for the definitive impression and maxillomandibular registration. Maxillary and mandibular acrylic sectional dentures were simultaneously delivered. Low caries activity, minimal occlusal force, appropriate plaque control, and simple designs for connecting portions of the two halves of the sectional dentures might lead to satisfactory results in this case. No problems have been observed for approximately 6 years after delivery of the acrylic sectional dentures for this microstomic patient.

  16. The influence of Copolimers Acrylic Acid onto Poli(Etilene Terephthalate)woven fabric

    International Nuclear Information System (INIS)

    Srie-Sunaryati

    2000-01-01

    To improve suitability of wearing poli etilene terephthalate (PET) wovenfabric, it need to enhance the ability in absorbing of water vapour. For theabove reason acrylic acid (AA) has been grafted onto PET wovenfabric(PET-g-AA). Fourier Transform Infrared (FT-IR) data show that poly(acrylic acid) have grafted onto PET woven fabric. Thermal propertiesobtained from DSC (Differential Scanning Calorimeter) measurements of PET-g-AA show that the grafting does not affect bulk properties of PET. Thedecrease of the tensile strength had occurred to PET-g-MMA, however it ratherinfluenced by the reaction time than the initial concentration of acrylicacid. (author)

  17. Preparation of poly (vinyl alcohol) membranes grafted with n-vinyl pyridine/ acrylic acid binary monomers

    International Nuclear Information System (INIS)

    Ajji, A.; Ali, A.

    2014-03-01

    Poly(vinyl alcohol) films were grafted with two monomers using gamma radiation, acrylic acid and N-vinyl pyridine. The influence of different parameters on the grafting yield was investigated as: the comonomer concentration and composition, and irradiation dose. The suitable conditions of the process had been determined to prepare PVA membranes have both properties of the two monomers, acrylic acid and vinyl pyridine as comonomer concentration and composition, and irradiation dose. Some properties of the membranes had been investigated as maximum swelling and grafting. Also the ability of the grafted films to adsorb some heavy metals and dyes was elaborated and discussed.(author)

  18. Application of Functionalized SWCNTs for Increase of Degradation Resistance of Acrylic Paint for Cars

    Directory of Open Access Journals (Sweden)

    Osiel Lucas Flores

    2013-01-01

    Full Text Available Physical properties of automotive acrylic paint are improved by incorporation of three different types of carbon nanotubes: single-wall carbon nanotubes (SWCNTs, OH-functionalized single-wall carbon nanotubes (OH-SWCNTs, and aniline-functionalized single-wall carbon nanotubes (aniline-SWCNTs. The formed composites are studied by electron miscroscopy methods and Raman spectrometry. It is found that the acrylic paints with addition of OH-SWCNTs and aniline-SWCNTs show better quality for their applications. In particular, the resistance against degradation by electron beam increased in ~500%.

  19. Catalytic Cracking of Lactide and Poly(Lactic Acid) to Acrylic Acid at Low Temperatures.

    Science.gov (United States)

    Terrade, Frédéric G; van Krieken, Jan; Verkuijl, Bastiaan J V; Bouwman, Elisabeth

    2017-05-09

    Despite being a simple dehydration reaction, the industrially relevant conversion of lactic acid to acrylic acid is particularly challenging. For the first time, the catalytic cracking of lactide and poly(lactic acid) to acrylic acid under mild conditions is reported with up to 58 % yield. This transformation is catalyzed by strong acids in the presence of bromide or chloride salts and proceeds through simple S N 2 and elimination reactions. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  20. Tandem Three-Component Reactions of Aldehyde, Alkyl Acrylate, and Dialkylmalonate Catalyzed by Ethyl Diphenylphosphine

    Directory of Open Access Journals (Sweden)

    Utpal Das

    2012-03-01

    Full Text Available A new highly efficient three-component reaction of alkyl acrylate, aldehyde and dialkyl malonate using ethyl diphenylphosphine as organocatalyst has been described. Various highly functional compounds bearing hydroxyl groups and the ester functions can be easily prepared in moderate to good yields according to our one-step procedure. The reactions are believed to proceed via Morita-Baylis-Hillman reactions of alkyl acrylate and aldehydes, followed by the Michael addition reactions of dialkyl malonates. Our reactions indicated that the intermediate species formed in the phosphine-catalyzed MBH reaction are an effective organic base to catalyze the Michael addition reactions of dialkyl malonates to the preformed MBH adducts.

  1. Chemical Fixation of CO{sub 2} to Acrylates Using Low-Valent Molybdenum Sources

    Energy Technology Data Exchange (ETDEWEB)

    Bernskoetter, Wesley

    2013-09-30

    The kinetic, mechanistic, and reactivity experiments to access the viability and possible reaction design of coupling of carbon dioxide and ethylene at a zerovalent molybdenum for the production of acrylates are described. A general model of the reaction mechanism has been outlined, including assessment of the rate limiting step in the reaction. Kinetic and computational data have valuated the influence of a range of tridentate ligand platforms on the rate of coupling. An in situ reduction and acrylate formation activity screen protocol has also been developed to aid in the technology development of this process. Portions of descriptions of the research products presented here have also been adapted with permission from journal publications.

  2. Synthesis and Characterization of Waterborne Fluoropolymers Prepared by the One-Step Semi-Continuous Emulsion Polymerization of Chlorotrifluoroethylene, Vinyl Acetate, Butyl Acrylate, Veova 10 and Acrylic Acid

    Directory of Open Access Journals (Sweden)

    Hongzhu Liu

    2017-01-01

    Full Text Available Waterborne fluoropolymer emulsions were synthesized using the one-step semi-continuous seed emulsion polymerization of chlorotrifluoroethylene (CTFE, vinyl acetate (VAc, n-butyl acrylate (BA, Veova 10, and acrylic acid (AA. The main physical parameters of the polymer emulsions were tested and analyzed. Characteristics of the polymer films such as thermal stability, glass transition temperature, film-forming properties, and IR spectrum were studied. Meanwhile, the weatherability of fluoride coatings formulated by the waterborne fluoropolymer and other coatings were evaluated by the quick ultraviolet (QUV accelerated weathering test, and the results showed that the fluoropolymer with more than 12% fluoride content possessed outstanding weather resistance. Moreover, scale-up and industrial-scale experiments of waterborne fluoropolymer emulsions were also performed and investigated.

  3. Tuning the Molar Composition of "Charge-Shifting" Cationic Copolymers Based on 2-(N,N-Dimethylamino)Ethyl Acrylate and 2-(tert-Boc-Amino)Ethyl Acrylate.

    Science.gov (United States)

    Ho, Hien The; Bohec, Maël Le; Frémaux, Julien; Piogé, Sandie; Casse, Nathalie; Fontaine, Laurent; Pascual, Sagrario

    2017-03-01

    Copolymers of 2-(N,N-dimethylamino)ethyl acrylate (DMAEA) and 2-(tert-Boc-amino)ethyl acrylate (tBocAEA) are synthesized by reversible addition-fragmentation chain transfer polymerization in a controlled manner with defined molar masses and narrow molar masses distributions (Ð ≤ 1.17). Molar compositions of the P(DMAEA-co-tBocAEA) copolymers are assessed by means of 1 H NMR. A complete screening in molar composition is studied from 0% of DMAEA to 100% of DMAEA. Reactivity ratios of both comonomers are determined by the extended Kelen-Tüdos method (r DMAEA = 0.81 and r t BocAEA = 0.99). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Characterisation of UV-cured acrylate networks by means of hydrolysis followed by aqueous size-exclusion combined with reversed-phase chromatography

    NARCIS (Netherlands)

    Peters, R.; Litvinov, V. M.; Steeman, P.; Dias, A. A.; Mengerink, Y.; van Benthem, R.; de Koster, C. G.; van der Wal, S. J.; Schoenmakers, P.

    2007-01-01

    UV-cured networks prepared from mixtures of di-functional (polyethylene-glycol di-acrylate) and mono-functional (2-ethylhexyl acrylate) acrylates were analysed after hydrolysis, by aqueous size-exclusion chromatography coupled to on-line reversed-phase liquid-chromatography. The mean network density

  5. Preparation, Characterization and Permeation Behavior of Poly(methyl acrylate-Poly(dimethyl siloxane-Poly(methyl acrylate Block Copolymer/Poly(vinyl acetate Blend Membranes

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Semsarzadeh

    2015-03-01

    Full Text Available Structure of polymeric materials is of the most important factors in determination of the characteristics and properties of the membranes. Various research and developments on polymeric membranes confirm the direct correlation between structure-properties of polymeric membranes. In this research, the structural outcome of poly(methyl acrylate-poly(dimethyl siloxane-poly(methyl acrylate/poly(vinyl acetate blend membranes and its relationship with gas permeation behavior of the blends were investigated. The flexible block copolymer of poly(methyl acrylate-poly(dimethyl siloxane-poly(methyl acrylate (PMA-PDMS-PMA was synthesized via atom transfer radical polymerization. Morphology and chemical structure of the synthesized block copolymer was investigated by Fourier transform infrared spectroscopy, proton nuclear magnetic resonance, gel permeation chromatography, X-ray diffraction analysis, differential scanning calorimetry and scanning electron microscopy. Blend membranes of PMA-PDMS-PMA and poly(vinyl acetate (PVAc were prepared by solution casting method in different compositions. By adding poly(vinyl acetate to PMA-PDMS-PMA block copolymer, the selectivity of the membranes for carbon dioxide/methane pair gases were increased by 55%. Fractional free volume (an indication of chain packing efficiency in blend membranes and dielectric constant (an indication of the molar volume and molar polarization of the blend membranes were obtained as the factors reflected the microstructural effect of PMA-PDMS-PMA and PVAc blend membranes. The efforts were directed toward expressing more precise structure-properties relationship of PMA-PDMS-PMA/PVAc blend membranes. The experimental permeability values of the blend membranes reported in this research were compared with the modified logarithmic model. The modified logarithmic model was evaluated for other blend membranes.

  6. Column, particularly extraction column, for fission and/or breeder materials

    International Nuclear Information System (INIS)

    Vietzke, H.; Pirk, H.

    1980-01-01

    An absorber rod with a B 4 C insert is situated in the long extraction column for a uranyl nitrate solution or a plutonium nitrate solution. The geometrical dimensions are designed for a high throughput with little corrosion. (DG) [de

  7. HETP evaluation of structured packing distillation column

    Directory of Open Access Journals (Sweden)

    A. E. Orlando Jr.

    2009-09-01

    Full Text Available Several tests with a hydrocarbon mixture of known composition (C8-C14, obtained from DETEN Chemistry S.A., have been performed in a laboratory distillation column, having 40mm of nominal diameter and 2.2m high, with internals of Sulzer DX gauze stainless steel structured packing. The main purpose of this work was to evaluate HETP of a structured packing laboratory scale distillation column, operating continuously. Six HETP correlations available in the literature were compared in order to find out which is the most appropriate for structured packing columns working with medium distillates. Prior to the experimental tests, simulation studies using commercial software PRO/II® were performed in order to establish the optimum operational conditions for the distillation, especially concerning operating pressure, top and bottom temperatures, feed location and reflux ratio. The results of PRO/II® were very similar to the analysis of the products obtained during continuous operation, therefore permitting the use of the properties calculated by that software on the theoretical models investigated. The theoretical models chosen for HETP evaluation were: Bravo, Rocha and Fair (1985; Rocha, Bravo and Fair (1993, 1996; Brunazzi and Pagliant (1997; Carlo, Olujić and Pagliant (2006; Olujić et al., (2004. Modifications concerning calculation of specific areas were performed on the correlations in order to fit them for gauze packing HETP evaluation. As the laboratory distillation column was operated continuously, different HETP values were found by the models investigated for each section of the column. The low liquid flow rates in the top section of the column are a source of error for HETP evaluation by the models; therefore, more reliable HETP values were found in the bottom section, in which liquid flow rates were much greater. Among the theoretical models, Olujić et al. (2004 has shown good results relative to the experimental tests. In addition, the

  8. How to select equivalent and complimentary reversed phase liquid chromatography columns from column characterization databases.

    Science.gov (United States)

    Borges, Endler M

    2014-01-07

    Three RP-LC column characterization protocols [Tanaka et al. (1989), Snyder et al. (PQRI, 2002), and NIST SRM 870 (2000)] were evaluated using both Euclidian distance and Principal Components Analysis to evaluate effectiveness at identifying equivalent columns. These databases utilize specific chromatographic properties such as hydrophobicity, hydrogen bonding, shape/steric selectivity, and ion exchange capacity of stationary phases. The chromatographic parameters of each test were shown to be uncorrelated. Despite this, the three protocols were equally successful in identifying similar and/or dissimilar stationary phases. The veracity of the results has been supported by some real life pharmaceutical separations. The use of Principal Component Analysis to identify similar/dissimilar phases appears to have some limitations in terms of loss of information. In contrast, the use of Euclidian distances is a much more convenient and reliable approach. The use of auto scaled data is favoured over the use of weighted factors as the former data transformation is less affected by the addition or removal of columns from the database. The use of these free databases and their corresponding software tools shown to be valid for identifying similar columns with equivalent chromatographic selectivity and retention as a "backup column". In addition, dissimilar columns with complimentary chromatographic selectivity can be identified for method development screening strategies. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Modeling of Crystalline Silicotitanate Ion Exchange Columns

    International Nuclear Information System (INIS)

    Walker, D.D.

    1999-01-01

    Non-elutable ion exchange is being considered as a potential replacement for the In-Tank Precipitation process for removing cesium from Savannah River Site (SRS) radioactive waste. Crystalline silicotitanate (CST) particles are the reference ion exchange medium for the process. A major factor in the construction cost of this process is the size of the ion exchange column required to meet product specifications for decontaminated waste. To validate SRS column sizing calculations, SRS subcontracted two reknowned experts in this field to perform similar calculations: Professor R. G. Anthony, Department of Chemical Engineering, Texas A ampersand 038;M University, and Professor S. W. Wang, Department of Chemical Engineering, Purdue University. The appendices of this document contain reports from the two subcontractors. Definition of the design problem came through several meetings and conference calls between the participants and SRS personnel over the past few months. This document summarizes the problem definition and results from the two reports

  10. Assessment of the flexural strength of two heat-curing acrylic resins for artificial eyes.

    Science.gov (United States)

    Fernandes, Aline Ursula Rocha; Portugal, Aline; Veloso, Letícia Rocha; Goiato, Marcelo Coelho; Santos, Daniela Micheline dos

    2009-01-01

    Prosthetic eyes are artificial substitutes for the eyeball, made of heat-curing acrylic resin, serving to improve the esthetic appearance of the mutilated patient and his/her inclusion in society. The aim of this study was to assess the flexural strength of two heat-curing acrylic resins used for manufacturing prosthetic eyes. Thirty-six specimens measuring 64 x 10 x 3.3 mm were obtained and divided into four groups: acrylic resin for artificial sclera N1 (Artigos Odontológicos Clássico, São Paulo, SP, Brazil), heat-cure water technique (GI) and microwave-cured (GII); colorless acrylic resin for prosthetic eyes (Artigos Odontológicos Clássico, São Paulo, SP, Brazil), heat-cure water technique (GIII) and microwave-cured (GIV). Mechanical tests using three point loads were performed in a test machine (EMIC, São José dos Pinhais, PR, Brazil). The analysis of variance and the Tukey test were used to identify significant differences (p < 0.01). Groups GII and GIV presented, respectively, the highest (98.70 +/- 11.90 MPa) and lowest means (71.07 +/- 8.93 MPa), with a statistically significant difference. The cure method used for the prosthetic eye resins did not interfere in their flexural strength. It was concluded that all the resins assessed presented sufficient flexural strength values to be recommended for the manufacture of prosthetic eyes.

  11. Electrochemical Impedance Spectroscopy Study on Corrosion Protection of Acrylate Nanocomposite on Mild Steel Doped Carbon Nanotubes

    International Nuclear Information System (INIS)

    Mahmud, M R; Akhir, M M; Shamsudin, M S; Afaah, A N; Aadila, A; Asib, N A M; Harun, M K; Abdullah, S; Alrokayan, Salman A H; Khan, Haseeb A; Rusop, M

    2015-01-01

    Acrylate:carbon nanotubes (A:CNTs) nanocomposite thin film was prepared by sol- gel technique. The corrosion coating protection of acrylate:carbon nanotubes (CNTs) nanocomposite thin film has been coated on mild steel characterised by electrochemical impedance spectrometer (EIS) measurement and equivalent circuit model are employed to analyse coating impedance for corrosion protection. In this study, 3.5 w/v % sodium chloride (NaCl) solution was immersed the acrylate:carbon nanotubes nanocomposite thin film. As the results, the surface morphology were found that there formation of carbon nanotubes with good distribution on acrylate-based coating. From EIS measurement, A:CNTs nanocomposite thin film with 0.4 w/v % contain of CNTs was exhibited the highest coating impedance from Nyquist graph after immersed in sodium chloride solution and may provide the excellent corrosion protection. The Bode plots have shown the impedance is high at the beginning from the time at high frequency and slightly decreases with value of frequency become smaller. (paper)

  12. Screening of Catalyst and Important Variable for The Esterification of Acrylic Acid with 2 Ethylhexanol

    Science.gov (United States)

    Ahmad, M. A. A.; Chin, S. Y.

    2017-06-01

    The global demand of 2-ethylhexyl acrylate (2EHA) market has witnessed a significant growth in the past few years and this growth is anticipated to increase in the coming years. 2EHA is one of the basic organic building blocks that mainly used in the production of coatings, adhesives, superabsorbents, thickeners and plastic additives. Homogenous acid-catalysed esterification of acrylic acid (AA) with 2-ethylhexanol (2EH) is commonly used for the production of 2EHA. The homogeneous catalysts such as sulfuric and para-toluene sulfonic acid have resulted the costly and complicated downstream process that generates acidic, corrosive and non-environmental friendly waste. Therefore, it is importance to develop a cheaper process that employing heterogeneous catalysts and alternative raw material from wastewater containing acrylic acid. In this research, the study for the esterification of AA with 2EH catalysed by ion-exchange resin was conducted. The best sulfonic acid functional cation-exchange resin among SK104, SK1B, PK208, PK216, PK228, RCP145, and RCP160 was screened. PK208 outperformed the other resins and it was used subsequently in the parametric studies. The effect of important parameters (initial concentration of acrylic acid (AA), temperature, molar ratio of reactant (AA and 2EH), catalyst loading, and polymerisation inhibitor loading) was studied using 2 factorial design to determine the significant parameters to the esterification. It was found that the initial concentration of AA and temperature were most significantly affecting the esterification of AA with 2EH.

  13. Dielectric properties of solution-grown-undoped and acrylic-acid ...

    Indian Academy of Sciences (India)

    Dielectric capacities and losses were measured, in the temperature (50–170°C) and frequency (01–100 kHz range), for undoped and acrylic acid (AA) doped ethyl cellulose (EC) films (thickness about 20 m) with progressive increase in the concentration of dopant in the polymer matrix. The variation of capacity with ...

  14. Evaluation of thermal conductivity of heat-cured acrylic resin mixed with A1203

    Directory of Open Access Journals (Sweden)

    Ebadian B.

    2002-08-01

    Full Text Available One of the most important characteristics of denture base is thermal conductivity. This property has a major role in secretions of salivary glands and their enzymes, taste of the food and gustatory response. Polymethyl methacrylate used in prosthodontics is relatively an insulator. Different materials such as metal fillers and ceramics have been used to solve this problem. The aim of this study was the evaluation of AI2O3 effect on thermal conductivity of heat-cured acrylic resin. Acrylic resin was mixed with AI2O3 in two different weight rates (15 and 20 % of weight. So, group 1 and 2 were divided on this basis. Samples with pure acrylic resin were considered as control group. 18 cylindrical patterns were made in 9x9 mm dimensions and thermocouple wires embedded in each sample to act as conductor. The specimens were put in water with 70±1°C thermal range for 10 minutes. Then, thermal conductivity was measured. The results were analyzed with variance analysis and Dunken test. There was significant difference between thermal conductivity of all groups in all period times. It the first seconds, thermal conductivity in groups 1 and 2 were more than control group. Therefore, for developing of thermal conductivity of acrylic resin, A1203 can be used. Certainly, other characteristic of new resin should be evaluated.

  15. Siloxane urethane acrylate radiation curable compounds for use in coating compositions

    International Nuclear Information System (INIS)

    Friedlander, C.B.; McMullen, J.C.

    1978-01-01

    Radiation curable compounds are disclosed which are derived from the reaction of siloxy-containing carbinol, a polyisocyanate and a polyfunctional compound having hydroxy and acrylic functional groups. The compounds have high cure rates, are compatible with other components of radiation curable, film forming compositions and impart good slip and other properties to cured film coatings

  16. The removable acrylic partial denture in primary care: the experience and satisfaction of dental surgeons

    Directory of Open Access Journals (Sweden)

    Rita de Cássia SILVA

    2017-11-01

    Full Text Available Abstract Introduction The guidelines of the National Politics of Oral Health have led to the inclusion of elemental prostheses in the list of Primary Care procedures. Objective This paper aimed to evaluate the performance and satisfaction of dental surgeons with the implementation of Acrylic Partial Dentures. Metodology The sample was composed by 159 dental surgeons (sample calculation, in Belo Horizonte, MG, Brazil, selected via raffle (simple random sampling. A structured questionnaire was built with 72 questions on the daily practice of the performance of dental surgeons, using the SurveyMonkey platform. Result The results showed that for most of dental surgeons, the inclusion on the list of primary care procedures was a positive initiative and they have enjoyed the experience of using Acrylic Partial Dentures. Dental surgeons who had graduated in private institutions reported to have had more failures than those who had graduated in public institutions. The better prepared dental surgeons reported less difficulties and failures, and the more satisfied professionals with the performance of Acrylic Partial Dentures related had also experienced fewer failures. Considering the indication, the majority of participants did it according to the protocol of the institution (only for anterior teeth but many revealed the use of dentures also for premolars. Conclusion Acrylic partial dentures have been a reality in the Brazilian social context even before their inclusion in the list of Primary Care procedures. Such inclusion indicates their relevance; however, it is necessary to have their confection systematized by a protocol in public services.

  17. Comparative study of the fatigue strength of five acrylic denture resins.

    Science.gov (United States)

    Gurbuz, Ozlem; Unalan, Fatma; Dikbas, Idil

    2010-11-01

    The aim of this in vitro study was to compare the fatigue resistance of three kinds of heat-polymerized acrylic resins (conventional heat-polymerized, rapid heat-polymerized, high impact acrylic resin), a kind of visible light-cured resin and a kind of self-cured acrylic resin. A total of 60 notched and un-notched specimens (65 mm x 10 mm x 3 mm) were fabricated, 12 from each material. The fatigue resistance was measured by applying repeated three-point bending deflection to the specimens. For statistical analysis, Kruskal-Wallis test followed by Dunn's multiple comparison tests were used. The Kruskal-Wallis test revealed significant differences in the fatigue resistance among some groups (pacrylic resin, but the differences were statistically non-significant according to Dunn's test (p>0.05). High impact acrylic resin was also found to have significantly higher fatigue resistance value than that of self-cured resin and light-cured resin (p0.05). (c) 2010 Elsevier Ltd. All rights reserved.

  18. The bond between acrylic resin denture teeth and the denture base: recommendations for best practice.

    Science.gov (United States)

    Radford, D R; Juszczyk, A S; Clark, R K F

    2014-02-01

    Failure of the bond between denture teeth and base acrylic resin has been shown to be a cause of denture failure leading to inconvenience and costly repair. The optimal combination of acrylic resin denture tooth, denture base material, laboratory protocol and processing method has not yet been established. Extensive research enables the following recommendations for best practice to be made. Adopt practices that maximise the strength of the bond: select appropriate denture teeth; select base acrylic resin from the same manufacturer as the denture teeth; remove the glaze from ridgelaps of the denture teeth; apply monomer to the ridgelaps of the denture teeth before packing the base acrylic resin dough; use the manufacturers' recommended liquid/powder ratio; follow the manufacturers' recommended curing cycle; allow the flask to cool slowly and rest before deflasking. Adopt practices that avoid factors detrimental to bond strength: remove all traces of wax from the ridge laps of the denture teeth; remove all traces of mould seal from the ridgelaps of the denture teeth. It is evident that a number of factors are involved which may assist or prevent formation of an adequate bond, suggesting that attention to detail by the dental technician may be the most critical factor.

  19. Deep UV patterning of acrylic masters for molding biomimetic dry adhesives

    Science.gov (United States)

    Sameoto, D.; Menon, C.

    2010-11-01

    We present a novel fabrication method for the production of biomimetic dry adhesives that allows enormous variation in fiber shapes and sizes. The technology is based on deep-UV patterning of commercial acrylic with semi-collimated light available from germicidal lamps, and combined careful processing conditions, material selection and novel developer choices to produce relatively high-aspect-ratio fibers with overhanging caps on large areas. These acrylic fibers are used as a master mold for subsequent silicone rubber negative mold casting. Because the bulk acrylic demonstrates little inherent adhesion to silicone rubbers, the master molds created in this process do not require any surface treatments to achieve high-yield demolding of interlocked structures. Multiple polymers can be cast from silicone rubber negative molds and this process could be used to structure smart materials on areas over multiple square feet. Using direct photopatterning of acrylic allows many of the desired structures for biomimetic dry adhesives to be produced with relative ease compared to silicon-based molding processes, including angled fibers and hierarchical structures. Optimized fiber shapes for a variety of polymers can be produced using this process, and adhesion measurements on a well-characterized polyurethane, ST-1060, are used to determine the effect of fiber geometry on adhesion performance.

  20. Coronary artery perforation successfully treated with tris-acryl gelatin microsphere embolisation.

    Science.gov (United States)

    To, Andrew C Y; El-Jack, Seifeddin S; Webster, Mark W I; Stewart, James T

    2008-10-01

    We describe a case of coronary artery perforation in a 76-year-old man, successfully treated by tris-acryl gelatin microsphere embolisation. This novel interventional embolic material is used in interventional radiology for arterial embolisation. We believe that this is the first report of its use for a coronary artery perforation.

  1. EB curable coating based on soy-oil fatty acid modified acrylate

    International Nuclear Information System (INIS)

    Yi min; Li Jun; Zhang Jianbo; Wang Weijing

    1998-01-01

    Soy-oil fatty acid was used to synthesize the soy-oil fatty acid modified acrylic coating by esterification reaction. After coating and EB curing, the results showed that the properties of the film were excellent, and it was suitable for the coating of wood furniture cured by EB

  2. IR laser ablative modification of poly(ethylene-co-acrylic acid) zinc salt

    Czech Academy of Sciences Publication Activity Database

    Blazevska-Gilev, J.; Šubrt, Jan; Bastl, Zdeněk; Pola, Josef

    2006-01-01

    Roč. 91, č. 12 (2006), s. 2834-2839 ISSN 0141-3910 Institutional research plan: CEZ:AV0Z40320502; CEZ:AV0Z40400503; CEZ:AV0Z40720504 Keywords : poly(ethylene-co-acrylic acid) zinc salt * laser ablation * laser degradation Subject RIV: CA - Inorganic Chemistry Impact factor: 2.174, year: 2006

  3. Long-term toughness of photopolymerizable (meth)acrylate networks in aqueous environments.

    Science.gov (United States)

    Smith, Kathryn E; Trusty, Phillip; Wan, Beatrice; Gall, Ken

    2011-02-01

    Photopolymerizable (meth)acrylate networks are potentially advantageous biomaterials due to their ability to be formed in situ, their fast synthesis rates and their tailorable material properties. The objective of this study was to evaluate how immersion time in phosphate-buffered saline (PBS) affects the toughness of photopolymerizable methyl acrylate (MA)-co-methyl methacrylate-co-poly(ethylene glycol) dimethacrylate networks containing various concentrations of MA. Stress-strain behavior was determined by performing tensile strain to failure testing after soaking in PBS for different periods (1 day up to 9 months). In tandem, differential scanning calorimetry and PBS content measurements were undertaken at each time point in order to determine whether time-dependent changes in toughness were related to changes in T(g) or PBS absorption. The effect of immersion time on network toughness was shown to be dependent upon composition in a manner related to the viscoelastic state of the polymer upon initial immersion in PBS. The results demonstrate that tough acrylate-based materials may not maintain their toughness after several months in PBS. In addition, decreasing the PBS content by changing the network hydrophobicity resulted in better toughness maintenance after 9 months. The results provide a possible means to toughen various amorphous acrylate-based implant materials that are being explored for load-bearing biomedical applications, beyond the systems considered in this work. Published by Elsevier Ltd.

  4. The Effects of Silicone and Acrylic Ear Mold Materials on Outer Ear Canal Resonance Characteristics.

    Science.gov (United States)

    Alnıaçık Erdoğan, Asuman; Arslan, Şeyda Nur

    2016-08-01

    The aim of this study is to investigate the effects of earmolds made of silicone and acrylic on outer ear canal resonance characteristics in terms of resonance frequency and amplitude measured in a hearing aid fitting. Outer ear canal resonance frequencies and amplitudes in open ears and those measured with silicone and acrylic ear molds were obtained from 30 participants between the ages of 20 and 25 years (average age, 22.0 years; 18 females and 12 males) with a real ear gain measurement. To observe the changes depending on probe tube placement, test-retest variation was investigated in 10 participants before the study. There was no statistically significant difference between open ear canal resonance frequencies and those measured with silicone and acrylic earmolds (p>0.05). the silicone earmold resonance amplitude values were statistically significantly lower than the open ear canal resonance amplitudes when compared to those of the acrylic earmolds (p<0.05). Depending on the changes occurring in outer ear resonance features as a result of earmold materials used in hearing aid fittings, the application of earmolds should be done by experienced specialists.

  5. Thermal behavior of flax and jute reinforced in matrix acrylic composite

    Czech Academy of Sciences Publication Activity Database

    Samal, Sneha Manjaree; Stuchlík, M.; Petrikova, I.

    2017-01-01

    Roč. 131, č. 2 (2017), s. 1-6 ISSN 1388-6150 Institutional support: RVO:68378271 Keywords : flax * jute * acrylic resin * composite * DMA * TG * FTIR Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.953, year: 2016

  6. Gold Nanoparticles Protected with Thiol-Derivatized Amphiphilic Poly(epsilon-caprolactone)-b-poly(acrylic acid)

    DEFF Research Database (Denmark)

    Javakhishvili, Irakli; Hvilsted, Søren

    2009-01-01

    ) of tent-butyl acrylate (tBA) in a controlled fashion by use of NiBr2(PPh3)(2) catalyst to produce Prot-PCL-b-PtBA with narrow polydispersities (1.17-1.39). Subsequent mild deprotection protocols provided HS-PCL-b-PAA. Reduction of a gold salt in the presence of this macroligand under thiol...

  7. Customized acrylic implants for reconstruction of extensive skull defects: an exception approach for selected patients

    Directory of Open Access Journals (Sweden)

    RAFAEL DENADAI PIGOZZI DA SILVA

    Full Text Available ABSTRACT Objective: to present our experience in the surgical treatment of extensive skullcap defects with customized acrylic implants. Methods: we conducted a retrospective analysis of patients with extensive skull defects undergoing acrylic cranioplasties between 2004 and 2013. We carefully selected all patients and classified surgical results based on three scales (craniofacial esthetics, improvement of facial symmetry and need for additional surgery. Results: fifteen patients underwent cranioplasty with intraoperative acrylic implants, whether manually customized (46.67% or made with prototyped three-dimensional biomodels (53.33%. There were two (13.33% complications (one infection with implant withdrawal and one seroma. We considered the craniofacial aesthetics excellent (50%, the degree of improvement of craniofacial symmetry satisfactory (57.14%, and the overall mean of surgical results according to the need for new surgeries was 1.5±0.52. Conclusion: cranioplasties of patients with extensive skullcap defects should obey careful and predetermined criteria, both for selection and for the acrylic implant customization method.

  8. Bio-based acrylic acid from sugar via propylene glycol and allyl alcohol

    NARCIS (Netherlands)

    Pramod, C. V.; Fauziah, R.; Seshan, K.; Lange, J. P.

    2018-01-01

    A new route for producing bio-based acrylic acid is proposed. It starts with the conversion of carbohydrates to propylene glycol, being main or by-product, and proceeds via a subsequent dehydration to allyl alcohol under gas-phase conditions over K-modified ZrO2 and a final oxidation over MoWVOx

  9. Antifungal and physical characteristics of modified denture base acrylic incorporated with silver nanoparticles.

    Science.gov (United States)

    Nam, Ki-Young; Lee, Cheong-Hee; Lee, Chul-Jae

    2012-06-01

    This study evaluated the antifungal and physical characteristics of denture base acrylic combined with silver nanoparticles. Polymerized denture acrylic disc specimens containing 0 (control), 1.0, 5.0, 10.0, 20.0 and 30.0 wt% of silver nanoparticles were placed on separate culture plate dish and 100 ìL samples of yeast suspension of Candida albicans strain were inoculated on each specimens and incubated at 37°C, for 24 h. The antifungal effects were evaluated as a number of viable cells in retrieved fungal suspension. To characterize physical aspects, specimens were tested for elution of silver cation (Ag(+)) at 24 h and 30th day, thermal analysis (TG/DTA), scanning electron microscope and energy dispersed X-ray analysis (SEM/EDX) and color stability. Significant reduced CFU was exhibited at 20.0 and 30.0 wt% of silver nanoparticles incorporated (p denture acrylic containing silver nanoparticles was accessed by TG/DTA and EDX analysis. The modified denture base acrylic combined with silver nanoparticles displayed antifungal properties and acted like latent antifungal material itself with low-releasing Ag(+), however, the improvement of poor color stability was still required. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  10. Glass fibre reinforced acrylic resin complete dentures: a 5-year clinical study.

    Science.gov (United States)

    Goguţă, Luciana Maria; Bratu, Dorin; Jivănescu, Anca; Erimescu, Raluca; Mărcăuţeanu, Corina

    2012-03-01

    The aim of the study was to establish the wear resistance of the glass fiber reinforced complete dentures comparative to the traditional acrylic complete dentures. Complete new dentures were made to replace old fractured 'un'-reinforced acrylic dentures. The total number of dentures was 30 and woven E-glass fibre reinforcements were used in maxillary complete dentures. Unidirectional E-glass fibre reinforcements were used as partial fibre reinforcements in mandibular complete dentures. Ten complete acrylic un-reinforced dentures were used as control. The follow-up period was 5 years and the recalls were made at 6 months. After 5 years of wearing the new dentures, the control dentures suffered seven fractures. After 5 years all the mandibular reinforced dentures were in good shape. The maxillary complete reinforced dentures suffered four partial fractures. Fracture lines were restricted by the glass fibre net and the patients could still use their dentures. Pre-impregnated E-glass fibre nets and polymer pre-impregnated E-glass unidirectional fibres are useful in reinforcing acrylic resin complete dentures especially were heavy occlusal forces are involved. Glass fibre reinforcement will be applied on the tension side in both cases (total fibre reinforcement and partial fibre reinforcement). The reinforcement cannot replace the necessary linings and occlusal adjustments. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  11. Synthesis of acrylate guar-gum for delivery of bio-active molecules

    Indian Academy of Sciences (India)

    Acrylated guar-gum chain is synthesized and analysed using Fourier transform infrared, differential scanning calorimetry and X-ray diffraction techniques to gain an insight into the particle size and structural features. Chlorpyrifos is then entrapped into the polymer, and its release is studied under various conditions. Critical ...

  12. Termite and fungal resistance of in situ polymerized tributyltin acrylate and acetylated Indonesian and USA wood

    Science.gov (United States)

    Rebecca E. Ibach; Yusuf Sudo. Hadi; Dodi. Nandika; Sulaeman. Yusuf; Yuliati. Indrayani

    2000-01-01

    Wood [Indonesian pine (IP), Indonesian Jabon (IJ) and USA southern yellow pine (USP)] was either in situ polymerized with tributyltin acrylate (TBTA) or acetylated and then exposed to termite and fungal degradation both in laboratory tests and field exposure. The TBTA woods had an average weight percent gain (WPG) of 11% for IP, 12% for IJ, and 10% for USP. The...

  13. Color Stability of Heat‑cure Acrylic Resin Subjected to Simulated ...

    African Journals Online (AJOL)

    Background: Regular usage of denture cleansers is recommended in complete denture wearers for effective plaque control, and these cleansers alter the physical properties of acrylic resin over a period of time. Thus, an in vitro study was carried out to assess the effect of denture cleansers on the color stability of heat‑cure ...

  14. Polymorphism and polymerisation of acrylic and methacrylic acid at high pressure

    DEFF Research Database (Denmark)

    Oswald, Iain D. H.; Urquhart, Andrew J.

    2011-01-01

    The polymorphism and polymerisation of two related acids have been investigated under high pressure conditions. Acrylic acid crystallises as a new polymorph at 0.65 GPa whilst methacrylic acid crystallises in a new polymorph at a higher pressure of 1.5 GPa. Both these new polymorphs exhibit similar...

  15. Effect of silver nano particles on flexural strength of acrylic resins.

    Science.gov (United States)

    Sodagar, Ahmad; Kassaee, Mohammad Zaman; Akhavan, Azam; Javadi, Negar; Arab, Sepideh; Kharazifard, Mohammad Javad

    2012-04-01

    Poly(methyl methacrylate), PMMA, is widely used for fabrication of removable orthodontic appliances. Silver nano particles (AgNps) have been added to PMMA because of their antimicrobial properties. The aim of this study is to investigate the effect of AgNps on the flexural strength of PMMA. Acrylic liquid containing 0.05% and 0.2% AgNps was prepared for two kinds of acrylic resins: Rapid Repair &Selecta Plus. Two groups without AgNps were used as control groups. For each one, flexural strength was investigated via Three Point Bending method for the 15 acrylic blocks. Two-way ANOVA, one way ANOVA and Tukey tests were used for statistical analysis. Rapid Repair without AgNps showed the highest flexural strength. Addition of 0.05% AgNps to Rapid Repair, significantly decreased its flexural strength while, continuing the addition up to 0.2% increased it nearly up to its primary level. In contrast, addition of AgNps to Selecta Plus increased its flexural strength but addition of 0.05% nano particles was more effective than 0.2%. The effect of AgNps on flexural strength of PMMA depends on several factors including the type of acrylics and the concentrations of nano particles. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  16. Deep UV patterning of acrylic masters for molding biomimetic dry adhesives

    International Nuclear Information System (INIS)

    Sameoto, D; Menon, C

    2010-01-01

    We present a novel fabrication method for the production of biomimetic dry adhesives that allows enormous variation in fiber shapes and sizes. The technology is based on deep-UV patterning of commercial acrylic with semi-collimated light available from germicidal lamps, and combined careful processing conditions, material selection and novel developer choices to produce relatively high-aspect-ratio fibers with overhanging caps on large areas. These acrylic fibers are used as a master mold for subsequent silicone rubber negative mold casting. Because the bulk acrylic demonstrates little inherent adhesion to silicone rubbers, the master molds created in this process do not require any surface treatments to achieve high-yield demolding of interlocked structures. Multiple polymers can be cast from silicone rubber negative molds and this process could be used to structure smart materials on areas over multiple square feet. Using direct photopatterning of acrylic allows many of the desired structures for biomimetic dry adhesives to be produced with relative ease compared to silicon-based molding processes, including angled fibers and hierarchical structures. Optimized fiber shapes for a variety of polymers can be produced using this process, and adhesion measurements on a well-characterized polyurethane, ST-1060, are used to determine the effect of fiber geometry on adhesion performance

  17. Effect of thermal cycling and disinfection on colour stability of denture base acrylic resin.

    Science.gov (United States)

    Goiato, Marcelo C; Dos Santos, Daniela M; Baptista, Gabriella T; Moreno, Amália; Andreotti, Agda M; Bannwart, Lisiane C; Dekon, Stefan F C

    2013-12-01

    The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n = 7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60 days. All specimens were thermal cycled between 5 and 55°C with 30-s dwell times for 1000 cycles before and after disinfection. The specimens' colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T1 ), after disinfection (D) and after second thermal cycling (T2 ). Colour differences (ΔE) were calculated between T1 and B (T1 B), D and B (DB), and T2 and B (T2 B) time-points.   The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time-points, except for the Lucitone acrylic resin. The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters. © 2012 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  18. The effect of bioburden on in-depth disinfection of denture base acrylic resin.

    Science.gov (United States)

    Saunders, T R; Guillory, V L; Gregoire, S T; Pimsler, M; Mitchell, M S

    1998-11-01

    This study evaluated the effectiveness of three different disinfectant solutions against denture bioburden absorbed within the depth of acrylic resin. Specimens were taken from dentures that had been worn by the patients for 15 to 20 years and were scheduled for replacement.

  19. SCLERAL SUTURE FIXATION TECHNIQUE FOR ONE-PIECE ACRYLIC INTRAOCULAR LENS.

    Science.gov (United States)

    Leung, Ella H; Mohsenin, Amir; Smiddy, William E

    2016-12-14

    To apply a previously published scleral fixation technique to secure one-piece acrylic intraocular lenses (IOLs) to the sclera. Retrospective, consecutive, noncomparative case series. All patients (16 eyes of 15 patients) who underwent scleral fixation of 1-piece acrylic IOLs using the loop method from 2014 to 2016 were included. The mean follow-up was 8.1 months. Repositioning of dislocated 1-piece acrylic IOLs was performed in 8 eyes, a primary implantation in 5 eyes, and IOL exchange in 3 eyes. All IOLs remained well-centered postoperatively. The vision improved from an initial best-corrected visual acuity of 0.97 ± 0.74 logMAR (Snellen equivalent ≈20/190) to 0.47 ± 0.49 logMAR (≈20/60, P = 0.031) at the last follow-up. The postoperative complications were self-limited. The previously reported scleral suture fixation technique can be readily applied to one-piece acrylic IOLs.

  20. Acrylic acid surface-modified contact lens for the culture of limbal stem cells.

    Science.gov (United States)

    Zhang, Hong; Brown, Karl David; Lowe, Sue Peng; Liu, Guei-Sheung; Steele, David; Abberton, Keren; Daniell, Mark

    2014-06-01

    Surface treatment to a biomaterial surface has been shown to modify and help cell growth. Our aim was to determine the best surface-modified system for the treatment of limbal stem cell deficiency (LSCD), which would facilitate expansion of autologous limbal epithelial cells, while maintaining cultivated epithelial cells in a less differentiated state. Commercially available contact lenses (CLs) were variously surface modified by plasma polymerization with ratios of acrylic acid to octadiene tested at 100% acrylic acid, 50:50% acrylic acid:octadiene, and 100% octadiene to produce high-, mid-, and no-acid. X-ray photoelectron spectroscopy was used to analyze the chemical composition of the plasma polymer deposited layer. Limbal explants cultured on high acid-modified CLs outgrew more cells. Immunofluorescence and RT2-PCR array results indicated that a higher acrylic acid content can also help maintain progenitor cells during ex vivo expansion of epithelial cells. This study provides the first evidence for the ability of high acid-modified CLs to preserve the stemness and to be used as substrates for the culture of limbal cells in the treatment of LSCD.