WorldWideScience

Sample records for in-vivo elemental analysis

  1. In-vivo elemental analysis at Birmingham 1968-1981

    International Nuclear Information System (INIS)

    Chettle, D.R.; Scott, M.C.

    1986-01-01

    Techniques have been developed to measure a number of elements in-vivo. Some have been measured by producing a radioactive isotope in the body by neutron bombardment and subsequently counting γ-rays given off during its decay. Measurements of calcium and sodium have been those most frequently used; copper, iron and phosphorus have also been measured in this way. Gamma-rays emitted 10 -18 s-10 -12 s following neutron capture have also been used for elemental analysis. This method, which involved detectors being in position by the subject during the neutron irradiation, has been widely applied to measurements of both nitrogen and cadmium. Preliminary studies of nuclear resonance scattering have suggested that this could be used for in-vivo elemental analysis, provided technical difficulties in source preparation could be overcome. Recently the use of X-ray fluorescence has been investigated for in-vivo analyses of lead in bone; the extension of this technique to measure mercury in the kidney is under consideration. (author)

  2. In-vivo elemental imaging of plants using in-air submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, Shigeo; Ishii, Keizo; Kikuchi, Yohei; Kawamura, Yu; Yamazaki, Hiromichi; Watanabe, Ryohei; Tashiro, Kumiko; Inoue, Chihiro

    2008-01-01

    We developed a PIXE analysis system which provides spatial distribution images of elements in a region of 3x3 cm 2 with a spatial resolution of ∼0.5 mm. We call this system a submilli-PIXE camera. For in-vivo imaging of plants, we combined the submilli-PIXE camera with an in-air analysis. The high-speed beam scanning and the in-air analysis also reduce the risk of damaging the plants, thus in-vivo imaging could be realized. We applied the in-air submilli-PIXE camera to phytoremediation research. Phytoremediation is a technology for cleaning metal-contaminated soils using plant physiology. To study accumulation mechanisms for heavy metals, elemental distribution in plant organ should be known as well as average concentration. Elemental images of fronds were obtained in-vivo without sample preparation. Elemental map of the fronds showed that arsenic was accumulated in the edges of Pteris vittata fronds. The in-air submilli-PIXE camera clearly shows the accumulation of arsenic in fronds. The in-air submilli-PIXE camera is an effective tool for undertaking phytoremediation research. (author)

  3. Application of cyclic activation to in vivo elemental analysis

    International Nuclear Information System (INIS)

    Spyrou, N.M.

    1984-01-01

    Experience over the past seven years with a prototype cyclic system, based on an oscillating 5Ci AmBe neutron source, suggests that multielemental in vivo analysis is possible and more specifically indicates that the determination of selenium and cadmium in liver may allow the examination of the interaction of the two elements at acceptable doses. Detection limits obtained for selenium and cadmium, in the same experiment but through different modes of detection i.e. the measurement of delayed gamma-rays from short-lived Se-77m (17.6 s) and prompt gamma-rays from Cd-114, in a cyclic sequence of irradiations, are 0.4 ppm and 6 ppm respectively, for a total irradiation period of 1800s and an equivalent dose to the irradiated region of 5mSv. The redesigning of the prototype system is being considered in order to decrease the detection limit of selenium to a value of 0.1 ppm or less and the effect of increasing the neutron flux tenfold is investigated. This could result in an improvement by a factor of 4 to 5 in detection, for the same dose. 36 references, 6 figures

  4. Multi-element analysis of the obese subject by in vivo neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Siwek, R A; Burkinshaw, L; Oxby, C B [Leeds General Infirmary (UK); Robinson, P A.J. [Saint James' s University Hospital, Leeds (UK)

    1984-06-01

    The Leeds facility for in vivo neutron activation analysis has been modified and calibrated for the simultaneous measurement of nitrogen, potassium, sodium, chlorine, phosphorus and calcium in obese patients weighing up to 210 kg. The effects of body size and shape were incorporated into the calibration by measuring 14 anthropomorphic phantoms of known composition representing individual patients being treated for obesity. The phantoms were constructed from tissue substitutes representing lean skeletal and adipose tissues, arranged to simulate the distributions of the corresponding tissues within the patients, as visualised by CT scanning. The precision of the method, determined by measuring a single phantom ten times over a period of ten weeks, is between two and three per cent for all elements except calcium, for which it is 11.3%. Accuracy is estimated to be similar to precision. The procedure has been used to study changes in body composition of patients undergoing therapeutic starvation.

  5. In vivo detection of the toxic heavy elements, lead and cadmium

    International Nuclear Information System (INIS)

    Thomas, B.J.; Thomas, B.W.; Davey, J.F.; Baddeley, H.; Summers, V.; Craswell, P.

    1986-01-01

    Portable systems for the in vivo measurement of the toxic heavy elements, cadmium and lead are described. The cadmium concentration in either the liver or left kidney is determined using a technique of thermal neutron capture gamma-ray analysis. X-ray fluorescence analysis is used to measure lead within the bone of the second phalanx of the index finger. Each of the measurements is used as an index of long term exposure to the element and applied to screening of exposed industrial workers. The results of these industrial health applications are presented. Clinical application of the measurements to the study of the involvement of these elements in renal disease is described in brief. (author)

  6. In vivo elemental analysis in occupational medicine using X-ray fluorescence

    International Nuclear Information System (INIS)

    Christoffersson, J.O.

    1986-01-01

    A technique for the in vivo determination of cadmium in the kidney cortex using X-ray fluorescence analysis (XRF) has been developed for clinical use. The method uses the Cd K-alfa X-rays. The radiation from the tube was polarized by scattering at 90 degrees in a plastic disc. Using a Si(Li) detector the minimum detectable concentration (MDC) of cadmium in the renal cortex was about 6 ppm for an effective dose equivalent of 3 micro-Sievert. The precision of the method was estimated to be about 23 percent. The clinical usefulness was confirmed by studying 20 occupationally exposed cadmium workers and three controls. The cadmium workers showed levels of cadmium in the kidney in the range 47-317 ppm, and controls showed levels below 30 ppm. Using XRF in vivo large-scale measurements of lead in the fingerbone of more than 100 lead workers were performed. The technique used included two 57-Co sources for excitation and a higher-purity Ge detector for the analysis of the Pb K-alfa X-rays. The MDC was about 20 ppm for an effective dose equivalent of 0.1 micro-Sievert. The precision of the method was estimated to be about 15 per cent. The in vivo measurements showed levels of fingerbone-Pb up to 148 ppm. The existence of a significant endogenous exposure from lead in the skeleton was confirmed. The fingerbone-Pb was correlated to time-integrated blood-Pb indicating that it could be used as a rough estimated of time-integrated exposure. The results from the measurements were used to develop a three-compartment (cortical bone, trabecular bone, blood/soft tissues) model. Using this model, lead levels in fingerbone, vertebrae and blood could be predicted in good agreement with observations. (author)

  7. Applications of nuclear technologies for in vivo elemental analysis

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Wielopolski, L.

    1983-01-01

    The objectives of this Department of Energy sponsored program are (1) to improve existing nuclear techniques, and (2) to develop new techniques for the analysis and solution of both medical problems and those associated with environmental pollution. Measurement facilities developed, to date, include a unique whole body counter, (WBC); a total body neutron activation facility (TBNAA); and a partial body activation facility (PBNAA). A variation of the prompt gamma neutron activation technique for measuring total body nitrogen has been developed to study body composition of cancer patients and the effect of nutritional regimens on the composition. These new techniques provide data in numerous clinical studies not previously amenable to investigation. The development and perfection of these techniques provide unique applications of radiation and radioisotopes to the early diagnosis of certain diseases and the evaluation of therapeutic programs. The PBNAA technique has been developed and calibrated for in vivo measurement of metals. Development has gone forward on prompt gamma neutron activation for the measurement of cadmium, x-ray fluorescence (XRF) for measurement of lead, and nuclear resonance scattering (NRS) for measurement of iron. Other techniques are being investigated for in vivo measurement of metals such as silicon and beryllium. Cardinal to all toxicological studies of Cd and other metal pollutants is an accurate and sensitive noninvasive technique for measuring organ burdens. In keeping with the mission of Brookhaven, these facilities have been made available to qualified scientists and members of the medical community throughout the world

  8. In vivo XRF measurements of heavy elements: Summary of a workshop

    International Nuclear Information System (INIS)

    Wielopolski, L.; Ryon, R.W.

    1995-01-01

    This is a brief summary of the first workshop of open-quotes In Vivo XRF Measurements of Heavy Elements,close quotes at the Denver Conference on Applications of X-Ray Analysis. In vivo x-ray fluorescence has been applied to medical applications since the 1960's, with much of the pioneering work being done in Sweden (1). First measurements were of iodine in the thyroid. Elements from iron ID uranium have now been measured, at natural and elevated levels. Elevated levels occur either unintentionally through occupational or environmental exposure, or intentionally through medical administration. Examples of measurements are cadmium in kidney and liver, platinum in kidneys and tumors, mercury in the wrists and skulls of dentists, lead in various near-surface bones, copper in the eye and iron in skin. Nearly all measurements make use of either silicon or germanium detectors; radioisotopes and less frequently x-ray tubes are used for excitation. One question that those who work in an analytical chemistry laboratory often ask concerns radiation doses. Concern for x-ray safety ordinarily precludes putting living subjects into the x-ray beam. It turns out that radiation exposure due to in vivo x-ray fluorescence is quite low. The effective dose values for measurement of tibia lead concentration using a 109 Cd source (30 minute exposure) ranges from 0.036 uSv for adults to 1.1 uSv for infants (less than one tenth of a single dental x-ray) (2). Lower effective doses were reported when an x-ray machine was Used to measure L x-rays (3). These values are far below proposed limits of negligibility (10 USv) and average annual U.S. natural background radiation (3000 uSv). 17 refs

  9. In vivo neutron activation analysis: body composition studies in health and disease

    International Nuclear Information System (INIS)

    Ellis, K.J.; Cohn, S.H.

    1984-01-01

    In vivo analysis of body elements by neutron activation is an important tool in medical research. It has provided a direct quantitative measure of body composition of human beings in vivo. Basic physiological differences related to age, sex, race, and body size have been assessed by this noninvasive technique. The diagnosis and management of patients with various metabolic disorders and diseases has also been demonstrated. Two major facilities at Brookhaven are being utilized exclusively for in vivo neutron activation analysis (IVNAA) of calcium, phosphorus, sodium, chlorine, nitrogen, hydrogen, and potassium. These elements serve as the basis for a four compartment model of body composition: protein, water, mineral ash, and fat. Variations in these compartments are demonstrated in clinical research programs investigating obesity, anorexia, cancer, renal failure, osteoporosis, and normal aging. IVNAA continues to provide a unique approach to the evaluation of clinical diagnosis, efficacy of therapeutic regimens, and monitoring of the aging process. Classical balance studies usually require the patient to be admitted to a hospital for extended periods of confinement. IVNAA, however, allows for clinical management of the patient on an out-patient basis, an important aspect for treatment of chronic diseases. 25 references, 3 figures, 5 tables

  10. In vivo neutron activation analysis: body composition studies in health and disease

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, K.J.; Cohn, S.H.

    1984-01-01

    In vivo analysis of body elements by neutron activation is an important tool in medical research. It has provided a direct quantitative measure of body composition of human beings in vivo. Basic physiological differences related to age, sex, race, and body size have been assessed by this noninvasive technique. The diagnosis and management of patients with various metabolic disorders and diseases has also been demonstrated. Two major facilities at Brookhaven are being utilized exclusively for in vivo neutron activation analysis (IVNAA) of calcium, phosphorus, sodium, chlorine, nitrogen, hydrogen, and potassium. These elements serve as the basis for a four compartment model of body composition: protein, water, mineral ash, and fat. Variations in these compartments are demonstrated in clinical research programs investigating obesity, anorexia, cancer, renal failure, osteoporosis, and normal aging. IVNAA continues to provide a unique approach to the evaluation of clinical diagnosis, efficacy of therapeutic regimens, and monitoring of the aging process. Classical balance studies usually require the patient to be admitted to a hospital for extended periods of confinement. IVNAA, however, allows for clinical management of the patient on an out-patient basis, an important aspect for treatment of chronic diseases. 25 references, 3 figures, 5 tables.

  11. In vivo detection of dynamics of elements in a living rat using multitracer technique

    International Nuclear Information System (INIS)

    Matsumoto, Ken-ichiro; Ui, Iori; Endo, Kazutoyo; Hirunuma, Rieko; Enomoto, Shuichi

    2002-01-01

    In vivo detection technique for radioactivity of the nuclide in the multitracer intravenously administered to a living rat was proposed using a special setting of lead slit and high-purity Ge semiconducting detector. In vivo time courses of the relative distribution of 7 Be, 4 8 V, 54 Mn, 58 Co, 65 Zn, 74 As, 75 Se, 83 Rb, 85 Sr, and 88 Y in upper abdomen and head of six week old male Wistar rats were analyzed. The dynamics of the elements were estimated using the relative distribution of 74 As as base line of blood concentration, since exogenous arsenic tracer is mainly taken into red blood cell. In the head, elements distributed mainly in bones or muscles except for Co and Se, while these elements in blood. In the upper abdomen, Mn, Co, Zn, Se, Rb, V, and Y are distributed in to the liver, which is a main organ for accumulating metals. It is the first report that dynamics of biotrace elements within an hour after administration was non-invasively obtained in living animal. (author)

  12. Regulatory elements in vivo in the promoter of the abscisic acid responsive gene rab17 from maize.

    Science.gov (United States)

    Busk, P K; Jensen, A B; Pagès, M

    1997-06-01

    The rab17 gene from maize is transcribed in late embryonic development and is responsive to abscisic acid and water stress in embryo and vegetative tissues. In vivo footprinting and transient transformation of rab17 were performed in embryos and vegetative tissues to characterize the cis-elements involved in regulation of the gene. By in vivo footprinting, protein binding was observed to nine elements in the promoter, which correspond to five putative ABREs (abscisic acid responsive elements) and four other sequences. The footprints indicated that distinct proteins interact with these elements in the two developmental stages. In transient transformation, six of the elements were important for high level expression of the rab17 promoter in embryos, whereas only three elements were important in leaves. The cis-acting sequences can be divided in embryo-specific, ABA-specific and leaf-specific elements on the basis of protein binding and the ability to confer expression of rab17. We found one positive, new element, called GRA, with the sequence CACTGGCCGCCC. This element was important for transcription in leaves but not in embryos. Two other non-ABRE elements that stimulated transcription from the rab17 promoter resemble previously described abscisic acid and drought-inducible elements. There were differences in protein binding and function of the five ABREs in the rab17 promoter. The possible reasons for these differences are discussed. The in vivo data obtained suggest that an embryo-specific pathway regulates transcription of the rab genes during development, whereas another pathway is responsible for induction in response to ABA and drought in vegetative tissues.

  13. Applications of nuclear technologies for in-vivo elemental analysis

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Wielopolski, L.

    1982-01-01

    Measurement facilities developed, to date, include a unique whole-body-counter, (WBC); a total-body neutron-activation facility (TBNAA); and a partial-body activation facility (PBNAA). A variation of the prompt-gamma neutron-activation technique for measuring total-body nitrogen was developed to study body composition of cancer patients and the effect of nutritional regimens on the composition. These new techniques provide data in numerous clinical studies not previously amenable to investigation. The development and perfection of these techniques provide unique applications of radiation and radioisotopes to the early diagnosis of certain diseases and the evaluation of therapeutic programs. The PBNAA technique has been developed and calibrated for in-vivo measurement of metals. Development has gone forward on prompt-gamma neutron activation for the measurement of cadmium, x-ray fluorescence (XRF) for measurement of iron. Other techniques are being investigated for in-vivo measurement of metals such as silicon and beryllium

  14. ED-XRF spectrometric analysis of comparative elemental composition of in vivo and in vitro roots of Andrographis paniculata (Burm.f.) Wall. ex Nees-a multi-medicinal herb

    Energy Technology Data Exchange (ETDEWEB)

    Behera, P.R., E-mail: priyaranjan2004@gmail.co [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Nayak, P [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Barik, D.P., E-mail: barikdp@yahoo.co [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Rautray, T.R., E-mail: trrautray@gmail.co [Ion Beam Laboratory, Institute of Physics, Bhubaneswar 751013, Orissa (India); Thirunavoukkarasu, M [Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Chand, P.K., E-mail: pkchanduubot@yahoo.co.i [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India)

    2010-12-15

    The multi-elemental composition of in vitro-proliferated root tissues of Andrographis paniculata (Burm.f.) Wall. ex Nees was compared with that of the naturally grown in vivo plants. Trace elements namely Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Rb, Sr and Pb in addition to two macro-elements K and Ca were identified and quantified in root tissues of both sources using the energy dispersive X-ray fluorescence (ED-XRF) technique. ED-XRF analysis was performed using Mo K X-rays generated from a secondary molybdenum target. The elemental content of in vitro roots was found to be at par with that of naturally grown plants of the same species. This opens up a possibility of exploiting in vitro root cultures as a viable, alternative and renewable source of phytochemicals of relevance, besides providing a means for conservation of the valuable natural resources.

  15. ED-XRF spectrometric analysis of comparative elemental composition of in vivo and in vitro roots of Andrographis paniculata (Burm.f.) Wall. ex Nees-a multi-medicinal herb

    International Nuclear Information System (INIS)

    Behera, P.R.; Nayak, P.; Barik, D.P.; Rautray, T.R.; Thirunavoukkarasu, M.; Chand, P.K.

    2010-01-01

    The multi-elemental composition of in vitro-proliferated root tissues of Andrographis paniculata (Burm.f.) Wall. ex Nees was compared with that of the naturally grown in vivo plants. Trace elements namely Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Rb, Sr and Pb in addition to two macro-elements K and Ca were identified and quantified in root tissues of both sources using the energy dispersive X-ray fluorescence (ED-XRF) technique. ED-XRF analysis was performed using Mo K X-rays generated from a secondary molybdenum target. The elemental content of in vitro roots was found to be at par with that of naturally grown plants of the same species. This opens up a possibility of exploiting in vitro root cultures as a viable, alternative and renewable source of phytochemicals of relevance, besides providing a means for conservation of the valuable natural resources.

  16. In vivo detection of dynamics of elements in a living rat using multitracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Ken-ichiro; Ui, Iori; Endo, Kazutoyo [Showa Pharmaceutical Univ., Dept. of Physical Chemistry, Machida, Tokyo (Japan); Hirunuma, Rieko; Enomoto, Shuichi [The Inst. of Physical and Chemical Research, Cyclotron Center, Division of Radioisotope Technology, Wako, Saitama (Japan)

    2002-04-01

    In vivo detection technique for radioactivity of the nuclide in the multitracer intravenously administered to a living rat was proposed using a special setting of lead slit and high-purity Ge semiconducting detector. In vivo time courses of the relative distribution of {sup 7}Be, 4{sup 8}V, {sup 54}Mn, {sup 58}Co, {sup 65}Zn, {sup 74}As, {sup 75}Se, {sup 83}Rb, {sup 85}Sr, and {sup 88}Y in upper abdomen and head of six week old male Wistar rats were analyzed. The dynamics of the elements were estimated using the relative distribution of {sup 74}As as base line of blood concentration, since exogenous arsenic tracer is mainly taken into red blood cell. In the head, elements distributed mainly in bones or muscles except for Co and Se, while these elements in blood. In the upper abdomen, Mn, Co, Zn, Se, Rb, V, and Y are distributed in to the liver, which is a main organ for accumulating metals. It is the first report that dynamics of biotrace elements within an hour after administration was non-invasively obtained in living animal. (author)

  17. In vivo bone strain and finite element modeling of a rhesus macaque mandible during mastication.

    Science.gov (United States)

    Panagiotopoulou, Olga; Iriarte-Diaz, José; Wilshin, Simon; Dechow, Paul C; Taylor, Andrea B; Mehari Abraha, Hyab; Aljunid, Sharifah F; Ross, Callum F

    2017-10-01

    Finite element analysis (FEA) is a commonly used tool in musculoskeletal biomechanics and vertebrate paleontology. The accuracy and precision of finite element models (FEMs) are reliant on accurate data on bone geometry, muscle forces, boundary conditions and tissue material properties. Simplified modeling assumptions, due to lack of in vivo experimental data on material properties and muscle activation patterns, may introduce analytical errors in analyses where quantitative accuracy is critical for obtaining rigorous results. A subject-specific FEM of a rhesus macaque mandible was constructed, loaded and validated using in vivo data from the same animal. In developing the model, we assessed the impact on model behavior of variation in (i) material properties of the mandibular trabecular bone tissue and teeth; (ii) constraints at the temporomandibular joint and bite point; and (iii) the timing of the muscle activity used to estimate the external forces acting on the model. The best match between the FEA simulation and the in vivo experimental data resulted from modeling the trabecular tissue with an isotropic and homogeneous Young's modulus and Poisson's value of 10GPa and 0.3, respectively; constraining translations along X,Y, Z axes in the chewing (left) side temporomandibular joint, the premolars and the m 1 ; constraining the balancing (right) side temporomandibular joint in the anterior-posterior and superior-inferior axes, and using the muscle force estimated at time of maximum strain magnitude in the lower lateral gauge. The relative strain magnitudes in this model were similar to those recorded in vivo for all strain locations. More detailed analyses of mandibular strain patterns during the power stroke at different times in the chewing cycle are needed. Copyright © 2017. Published by Elsevier GmbH.

  18. In vivo identification of promoter elements and transcription factors mediating activation of hepatic HMG-CoA reductase by T{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Boone, Lindsey R.; Niesen, Melissa I. [Department of Molecular Medicine, College of Medicine, University of South Florida, Tampa, FL (United States); Jaroszeski, Mark [Department of Chemical and Biomedical Engineering, College of Engineering, University of South Florida, Tampa, FL (United States); Ness, Gene C., E-mail: gness@hsc.usf.edu [Department of Molecular Medicine, College of Medicine, University of South Florida, Tampa, FL (United States)

    2009-07-31

    The promoter elements and transcription factors necessary for triiodothyronine (T{sub 3}) induction of hepatic HMG-CoA reductase (HMGR) were investigated by transfecting rat livers with wild type and mutant HMGR promoter-luciferase constructs using in vivo electroporation. Mutations in the sterol response element (SRE), nuclear factor-y (NF-Y) site, and the newly identified upstream transcription factor-2 (USF-2) site essentially abolished the T{sub 3} response. Chromatin immunoprecipitation (ChIP) analysis demonstrated that T{sub 3} treatment caused a 4-fold increase in in vivo binding of USF-2 to the HMGR promoter. Co-transfection of the wild type HMGR promoter with siRNAs to USF-2, SREBP-2, or NF-Y nearly abolished the T{sub 3} induction, as measured by promoter activity. These data provide in vivo evidence for functional roles for USF-2, SREBP-2, and NF-Y in mediating the T{sub 3}-induction of hepatic HMGR transcription.

  19. In-Field, In Situ, and In Vivo 3-Dimensional Elemental Mapping for Plant Tissue and Soil Analysis Using Laser-Induced Breakdown Spectroscopy

    Directory of Open Access Journals (Sweden)

    Chunjiang Zhao

    2016-10-01

    Full Text Available Sensing and mapping element distributions in plant tissues and its growth environment has great significance for understanding the uptake, transport, and accumulation of nutrients and harmful elements in plants, as well as for understanding interactions between plants and the environment. In this study, we developed a 3-dimensional elemental mapping system based on laser-induced breakdown spectroscopy that can be deployed in- field to directly measure the distribution of multiple elements in living plants as well as in the soil. Mapping is performed by a fast scanning laser, which ablates a micro volume of a sample to form a plasma. The presence and concentration of specific elements are calculated using the atomic, ionic, and molecular spectral characteristics of the plasma emission spectra. Furthermore, we mapped the pesticide residues in maize leaves after spraying to demonstrate the capacity of this method for trace elemental mapping. We also used the system to quantitatively detect the element concentrations in soil, which can be used to further understand the element transport between plants and soil. We demonstrate that this method has great potential for elemental mapping in plant tissues and soil with the advantages of 3-dimensional and multi-elemental mapping, in situ and in vivo measurement, flexible use, and low cost.

  20. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zimian; Pierson, Richard N [Obesity Research Center, St Luke' s-Roosevelt Hospital, Columbia University, College of Physicians and Surgeons, New York, NY (United States); Heymsfield, Steven B [Clinical Research, Metabolism, Merck Research Laboratories, Rahway, NJ (United States); Chen Zhao [Mel and Enid Zuckerman College of Public Health, University of Arizona, Tucson, AZ (United States); Zhu Shankuan, E-mail: zw28@columbia.ed [Obesity and Body Composition Research Center, Zhejiang University, School of Public Health, Hangzhou (China)

    2010-05-07

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R{sub ST} value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R{sub ST} concept depends on the mass of each major element in the human body. The DXA R{sub ST} values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R{sub ST} value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body {sup 40}K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R{sub ST} values. The DXA R{sub ST} values were strongly associated with the R{sub ST} values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted R{sub ST} to systematically exceed the DXA-measured R{sub ST} (mean {+-} SD, 1.389 {+-} 0.024 versus 1.341 {+-} 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 {+-} 12.0% versus 24.9 {+-} 11.1%, r = 0.983, P < 0.001). DXA R{sub ST} is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  1. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    International Nuclear Information System (INIS)

    Wang Zimian; Pierson, Richard N; Heymsfield, Steven B; Chen Zhao; Zhu Shankuan

    2010-01-01

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R ST value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R ST concept depends on the mass of each major element in the human body. The DXA R ST values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R ST value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body 40 K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R ST values. The DXA R ST values were strongly associated with the R ST values predicted from elemental content (r = 0.976, P ST to systematically exceed the DXA-measured R ST (mean ± SD, 1.389 ± 0.024 versus 1.341 ± 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 ± 12.0% versus 24.9 ± 11.1%, r = 0.983, P ST is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  2. In-vivo assessment of femoral bone strength using Finite Element Analysis (FEA based on routine MDCT imaging: a preliminary study on patients with vertebral fractures.

    Directory of Open Access Journals (Sweden)

    Hans Liebl

    Full Text Available To experimentally validate a non-linear finite element analysis (FEA modeling approach assessing in-vitro fracture risk at the proximal femur and to transfer the method to standard in-vivo multi-detector computed tomography (MDCT data of the hip aiming to predict additional hip fracture risk in subjects with and without osteoporosis associated vertebral fractures using bone mineral density (BMD measurements as gold standard.One fresh-frozen human femur specimen was mechanically tested and fractured simulating stance and clinically relevant fall loading configurations to the hip. After experimental in-vitro validation, the FEA simulation protocol was transferred to standard contrast-enhanced in-vivo MDCT images to calculate individual hip fracture risk each for 4 subjects with and without a history of osteoporotic vertebral fractures matched by age and gender. In addition, FEA based risk factor calculations were compared to manual femoral BMD measurements of all subjects.In-vitro simulations showed good correlation with the experimentally measured strains both in stance (R2 = 0.963 and fall configuration (R2 = 0.976. The simulated maximum stress overestimated the experimental failure load (4743 N by 14.7% (5440 N while the simulated maximum strain overestimated by 4.7% (4968 N. The simulated failed elements coincided precisely with the experimentally determined fracture locations. BMD measurements in subjects with a history of osteoporotic vertebral fractures did not differ significantly from subjects without fragility fractures (femoral head: p = 0.989; femoral neck: p = 0.366, but showed higher FEA based risk factors for additional incident hip fractures (p = 0.028.FEA simulations were successfully validated by elastic and destructive in-vitro experiments. In the subsequent in-vivo analyses, MDCT based FEA based risk factor differences for additional hip fractures were not mirrored by according BMD measurements. Our data suggests, that MDCT

  3. Can glycogen be measured by in vivo neutron activation analysis?

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Smith, A.H.; King, R.F.G.H.; Smith, M.A.

    1992-01-01

    The object of this note is to examine the feasibility of measuring liver glycogen using in vivo neutron activation analysis. The authors present equations which allow the mass of glycogen to be expressed in terms of the masses of oxygen, hydrogen, carbon and nitrogen. Using the most precise, published measurements of these elements, the standard deviation in the estimate of liver glycogen was 34 g. The magnitude of this error precluded observing changes in liver glycogen which are normally in the range 16 g to 72 g. However, this technique might be useful in detecting transient high concentrations of liver glycogen.(UK)

  4. In vivo trace element speciation study by using enriched stable isotopic tracer technique

    International Nuclear Information System (INIS)

    Feng Weiyue; Chai Zhifang; Shi Junwen; Ding Wenjun

    2005-01-01

    In contrast to the radioactive tracer method, the enriched stable isotopic technique used in life sciences will not cause radiation damage to cells and its operation will be no radioactive risk, In our laboratory, the enriched stable isotopes Cr-50, Hg-196 and Hg-198 combined with biochemical separation, neutron activation analysis (NAA) and inductively coupled plasma mass spectrometry (ICP-IVIS) have been used to investigate the element speciation in vivo. Chromium (Cr) is proposed to act as a potentiator of insulin action in animals and human beings. Its deficiency induces the symptoms resembling diabetes and its supplement can alleviate these symptoms. However, as the concentration of Cr in vivo is usually at ultratrace level(- ng/g), its speciation study is usually difficult, since it is almost impossible to avoid the exogenous Cr contamination caused by separation and determination processes. Therefore, in this study, 50 Cr 2 O 3 with 94.2% 50 Cr was used as a tracer combined with gel chromatography to study the Cr speciation in serum, liver, urine and other tissues of healthy and diabetic rats. The Cr concentrations can be determined via 50 Cr(n, γ) 51 Cr by NAA, which is ideally suited for the ultratrace element analyses due to its high precision, accuracy and sensitivity. Such research have found that the most quantity of chromium in vivo is mainly combined with high molecular weight proteins, which is later identified as transferrin and low molecular weight protein is mainly excreted from urine. Mercury is listed by the International Program of Chemical Safety as one of the six most dangerous chemicals in the global environment. Mercury compounds in the environment are often difficult to degrade. However, the mechanism on mercury toxicity to developing children following long term and low dose of mercury exposure is still not clear. Therefore, high sensitive method in vivo needs to be developed to study such low level mercury toxicity to fetus In this

  5. Incorporating in vivo fall assessments in the simulation of femoral fractures with finite element models

    NARCIS (Netherlands)

    Zijden, A.M. van der; Janssen, D.W.; Verdonschot, N.J.J.; Groen, B.E.; Nienhuis, B.; Weerdesteijn, V.G.M.; Tanck, E.J.M.

    2015-01-01

    Femoral fractures are a major health issue. Most experimental and finite element (FE) fracture studies use polymethylmethacrylate cups on the greater trochanter (GT) to simulate fall impact loads. However, in vivo fall studies showed that the femur is loaded distally from the GT. Our objective was

  6. Modelling optimization involving different types of elements in finite element analysis

    International Nuclear Information System (INIS)

    Wai, C M; Rivai, Ahmad; Bapokutty, Omar

    2013-01-01

    Finite elements are used to express the mechanical behaviour of a structure in finite element analysis. Therefore, the selection of the elements determines the quality of the analysis. The aim of this paper is to compare and contrast 1D element, 2D element, and 3D element used in finite element analysis. A simple case study was carried out on a standard W460x74 I-beam. The I-beam was modelled and analyzed statically with 1D elements, 2D elements and 3D elements. The results for the three separate finite element models were compared in terms of stresses, deformation and displacement of the I-beam. All three finite element models yield satisfactory results with acceptable errors. The advantages and limitations of these elements are discussed. 1D elements offer simplicity although lacking in their ability to model complicated geometry. 2D elements and 3D elements provide more detail yet sophisticated results which require more time and computer memory in the modelling process. It is also found that the choice of element in finite element analysis is influence by a few factors such as the geometry of the structure, desired analysis results, and the capability of the computer

  7. The use of reference materials in the elemental analysis of biological samples

    International Nuclear Information System (INIS)

    Bowen, H.J.M.

    1975-01-01

    Reference materials (RMs) are useful to compare the accuracy and precision of laboratories and techniques. The desirable properties of biological reference materials are listed, and the problems of production, homogenization and storage described. At present there are only 10 biological RMs available compared with 213 geological and 520 metallurgical RMs. There is a need for more biological RMs including special materials for microprobe analysis and for in vivo activation analysis. A study of 650 mean values for elements in RM Kale, analysed by many laboratories, leads to the following conclusions. 61% of the values lie within +-10% of the best mean, and 80% lie within +-20% of the best mean. Atomic absorption spectrometry gives results that are 5-30% high for seven elements, while intrumental neutron activation analysis gives low and imprecise results for K. Other techniques with poor interlaboratory precision include neutron activation for Mg, polarography for Zn and arc-spectrometry for many elements. More than half the values for elements in Kale were obtained by neutron activation, confirming the importance of this technique and the need for RMs. As a rough estimate, 6 x 10 9 elemental analyses of biological materials are carried out each year, mostly by medical, agricultural and food scientists. It seems likely that a substantial percentage of these are inaccurate, a situation that might be improved by quality control using standard RMs. (author)

  8. Cadmium analysis in vivo

    International Nuclear Information System (INIS)

    Bergman, R.

    1980-12-01

    The report describes the development of a method for in vivo Cd-analysis. The method is based on the analysis of the prompt gamma radiation which is emitted by neutron capture of the isotope Cd113. Different parts of the body can be analysed selectively by neutrons in the interval of 1 to 100 KeV. The results show that the level of Cd in Kidneys can be measured without exceeding the dose of 40 mrad and that only 20% uncertainty is introduced when analysing Cd. The development has been made at the R2 reactor in Studsvik using 25 KeV neutrons. (G.B.)

  9. Application of spectral decomposition analysis to in vivo quantification of aluminum by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Comsa, D.C. E-mail: comsadc@mcmaster.ca; Prestwich, W.V.; McNeill, F.E.; Byun, S.H

    2004-12-01

    The toxic effects of aluminum are cumulative and result in painful forms of renal osteodystrophy, most notably adynamic bone disease and osteomalacia, but also other forms of disease. The Trace Element Group at McMaster University has developed an accelerator-based in vivo procedure for detecting aluminum body burden by neutron activation analysis (NAA). Further refining of the method was necessary for increasing its sensitivity. In this context, the present study proposes an improved algorithm for data analysis, based on spectral decomposition. A new minimum detectable limit (MDL) of (0.7{+-}0.1) mg Al was reached for a local dose of (20{+-}1) mSv. The study also addresses the feasibility of a new data acquisition technique, the electronic rejection of the coincident events detected by a NaI(Tl) system. It is expected that the application of this technique, together with spectral decomposition analysis, would provide an acceptable MDL for the method to be valuable in a clinical setting.

  10. In vivo X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Ahlgren, L.

    1980-02-01

    Measurements on five occupationally exposed persons have shown that it is possible to use X-ray fluorescence analysis for in vivo measurements of lead in the skeleton. The technique for calibrating in vivo X-ray fluorescence measurements of lead in bone tissue has been studied in detail and a two-component phantom simulating the bone and the soft tissue parts of the finger constructed. The technique has been used for in vivo measurements on 22 occupationally exposed persons. The minimum detectable concentration of lead in fingerbones was found to be around 20 μg x g -1 . The lead concentrations in their skeletons and blood were compared: the correlation was poor. The variations in lead concentrations in the skeleton have been studied in occupationally exposed persons and in samples from archaeological skeletons. The sensitivity and the minimum detectable concentration of cadmium in the kidney cortex in in vivo measurements has been studied by measurements on kidney models. The minimum detectable concentration was 20 μg x g -1 at a skin-kidney distance of 30 mm and 40 μg x g -1 at 40 mm. Five persons occupationally exposed were studied. (Author)

  11. In Vivo Enhancer Analysis Chromosome 16 Conserved NoncodingSequences

    Energy Technology Data Exchange (ETDEWEB)

    Pennacchio, Len A.; Ahituv, Nadav; Moses, Alan M.; Nobrega,Marcelo; Prabhakar, Shyam; Shoukry, Malak; Minovitsky, Simon; Visel,Axel; Dubchak, Inna; Holt, Amy; Lewis, Keith D.; Plajzer-Frick, Ingrid; Akiyama, Jennifer; De Val, Sarah; Afzal, Veena; Black, Brian L.; Couronne, Olivier; Eisen, Michael B.; Rubin, Edward M.

    2006-02-01

    The identification of enhancers with predicted specificitiesin vertebrate genomes remains a significant challenge that is hampered bya lack of experimentally validated training sets. In this study, weleveraged extreme evolutionary sequence conservation as a filter toidentify putative gene regulatory elements and characterized the in vivoenhancer activity of human-fish conserved and ultraconserved1 noncodingelements on human chromosome 16 as well as such elements from elsewherein the genome. We initially tested 165 of these extremely conservedsequences in a transgenic mouse enhancer assay and observed that 48percent (79/165) functioned reproducibly as tissue-specific enhancers ofgene expression at embryonic day 11.5. While driving expression in abroad range of anatomical structures in the embryo, the majority of the79 enhancers drove expression in various regions of the developingnervous system. Studying a set of DNA elements that specifically droveforebrain expression, we identified DNA signatures specifically enrichedin these elements and used these parameters to rank all ~;3,400human-fugu conserved noncoding elements in the human genome. The testingof the top predictions in transgenic mice resulted in a three-foldenrichment for sequences with forebrain enhancer activity. These datadramatically expand the catalogue of in vivo-characterized human geneenhancers and illustrate the future utility of such training sets for avariety of iological applications including decoding the regulatoryvocabulary of the human genome.

  12. Direct restoration modalities of fractured central maxillary incisors: A multi-levels validated finite elements analysis with in vivo strain measurements.

    Science.gov (United States)

    Davide, Apicella; Raffaella, Aversa; Marco, Tatullo; Michele, Simeone; Syed, Jamaluddin; Massimo, Marrelli; Marco, Ferrari; Antonio, Apicella

    2015-12-01

    To quantify the influence of fracture geometry and restorative materials rigidity on the stress intensity and distribution of restored fractured central maxillary incisors (CMI) with particular investigation of the adhesive interfaces. Ancillary objectives are to present an innovative technology to measure the in vivo strain state of sound maxillary incisors and to present the collected data. A validation experimental biomechanics approach has been associated to finite element analysis. FEA models consisted of CMI, periodontal ligament and the corresponding alveolar bone process. Three models were created representing different orientation of the fracture planes. Three different angulations of the fracture plane in buccal-palatal direction were modeled: the fracture plane perpendicular to the long axis in the buccal-palatal direction (0°); the fracture plane inclined bucco-palatally in apical-coronal direction (-30°); the fracture plane inclined palatal-buccally in apical-coronal direction (+30°). First set of computing runs was performed for in vivo FE-model validation purposes. In the second part, a 50N force was applied on the buccal aspect of the CMI models. Ten patients were selected and subjected to the strain measurement of CMI under controlled loading conditions. The main differences were noticed in the middle and incisal thirds of incisors crowns, due to the presence of the incisal portion restoration. The stress intensity in -30° models is increased in the enamel structure close to the restoration, due to a thinning of the remaining natural tissues. The rigidity of the restoring material slightly reduces such phenomenon. -30° model exhibits the higher interfacial stress in the adhesive layer with respect to +30° and 0° models. The lower stress intensity was noticed in the 0° models, restoration material rigidity did not influenced the interfacial stress state in 0° models. On the contrary, material rigidity influenced the interfacial stress state

  13. In vivo and in vitro study of the 99mTc-DMSA radiopharmaceutical connection to blood elements

    International Nuclear Information System (INIS)

    Freitas, Rosimeire de S.; Gomes, Maria L.; Mattos, Deise M.M.; Moreno, Silvana R.F.; Dire, Glaucio F.; Lima, Elaine A.; Lima-Filho, Guilherme L.; Aleixo, Luiz Claudio; Bernardo-Filho, Mario; Instituto Nacional do Cancer, Rio de Janeiro

    2002-01-01

    Radiopharmaceuticals are widely used in nuclear medicine. The comprehension of their uptake mechanism in target organs, as well as their clearance may depend on the elucidation of their biochemical characteristics, for instance, their binding to blood elements. The reported precipitating studies of blood with radiopharmaceuticals have shown that the results can not be easily compared. Then, we decide evaluate of the binding proteins on the blood elements using trichloroacetic acid (TCA) to determine the radioactivity of the dimercaptosuccinic acid with technetium-99m (99mTc-DMSA) present in precipitating plasma (P) and blood cells (BC). Depending on the TCA concentration we have determined different values in the insoluble fractions of the plasma when the in vivo and in vitro evaluations were carried out. (author)

  14. In vivo predictive dissolution: transport analysis of the CO2 , bicarbonate in vivo buffer system.

    Science.gov (United States)

    Krieg, Brian J; Taghavi, Seyed Mohammad; Amidon, Gordon L; Amidon, Gregory E

    2014-11-01

    Development of an oral in vivo predictive dissolution medium for acid drugs with a pKa in the physiological range (e.g., Biopharmaceutics Classification System Class IIa) requires transport analysis of the complex in vivo CO2 /bicarbonate buffering system. In this report, we analyze this buffer system using hydrodynamically defined rotating disk dissolution. Transport analysis of drug flux was predicted using the film model approach of Mooney et al based on equilibrium assumptions as well as accounting for the slow hydration reaction, CO2 + H2 O → H2 CO3 . The accuracy of the models was compared with experimentally determined results using the rotating disk dissolution of ibuprofen, indomethacin, and ketoprofen. The equilibrium and slow hydration reaction rate models predict significantly different dissolution rates. The experimental results are more accurately predicted by accounting for the slow hydration reaction under a variety of pH and hydrodynamic conditions. Although the complex bicarbonate buffering system requires further consideration given its dynamic nature in vivo, a simplifying irreversible reaction (IRR) transport analysis accurately predicts in vitro rotating disk dissolution rates of several carboxylic acid drugs. This IRR transport model provides further insight into bicarbonate buffer and can be useful in developing more physiologically relevant buffer systems for dissolution testing. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  15. Techniques of in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Chettle, D.R.; Fremlin, J.H.

    1984-01-01

    This review is dealt with under the following headings, intended to reflect the different factors affecting the measurement sensitivity, starting with the choice of neutron source and proceeding, through the reaction characteristics, to the detection system, the questions of dosimetry and ethical constraints being also discussed: 1) neutron sources, slowing down and interaction processes, energy spectrum and flux uniformity, timing 2) neutron reactions used for in vivo analyses 3) detectors, choice, geometrical considerations and detector shielding 4) data collection and processing 5) interpretation, major elements, absolute or sequential measurements, relationship to other parameters 6) dosimetry, framework for dose levels, biological effects of neutron interactions, neutron doses in practice 7) implications for measurement of calcium, nitrogen and cadmium. (U.K.)

  16. Medical applications of in vivo neutron inelastic scattering and neutron activation analysis: Technical similarities to detection of explosives and contraband

    International Nuclear Information System (INIS)

    Kehayias, J.J.

    2001-01-01

    Nutritional status of patients can be evaluated by monitoring changes in elemental body composition. Fast neutron activation (for N and P) and neutron inelastic scattering (for C and O) are used in vivo to assess elements characteristic of specific body compartments. There are similarities between the body composition techniques and the detection of hidden explosives and narcotics. All samples have to be examined in depth and the ratio of elements provides a 'signature' of the chemical of interest. The N/H and C/O ratios measure protein and fat content in the body. Similarly, a high C/O ratio is characteristic of narcotics and a low C/O together with a strong presence of N is a signature of some explosives. The available time for medical applications is about 20 min - compared to a few seconds for the detection of explosives - but the permitted radiation exposure is limited. In vivo neutron analysis is used to measure H, O, C, N, P, Na, Cl, and Ca for the study of the mechanisms of lean tissue depletion with aging and wasting diseases, and to investigate methods of preserving function and quality of life in the elderly

  17. In vivo analysis of the Notch receptor S1 cleavage.

    Directory of Open Access Journals (Sweden)

    Robert J Lake

    2009-08-01

    Full Text Available A ligand-independent cleavage (S1 in the extracellular domain of the mammalian Notch receptor results in what is considered to be the canonical heterodimeric form of Notch on the cell surface. The in vivo consequences and significance of this cleavage on Drosophila Notch signaling remain unclear and contradictory. We determined the cleavage site in Drosophila and examined its in vivo function by a transgenic analysis of receptors that cannot be cleaved. Our results demonstrate a correlation between loss of cleavage and loss of in vivo function of the Notch receptor, supporting the notion that S1 cleavage is an in vivo mechanism of Notch signal control.

  18. Analysis of clustered point mutations in the human ribosomal RNA gene promoter by transient expression in vivo

    International Nuclear Information System (INIS)

    Jones, M.H.; Learned, R.M.; Tjian, R.

    1988-01-01

    The authors have mapped the cis regulatory elements required in vivo for initiation at the human rRNA promoter by RNA polymerase I. Transient expression in COS-7 cells was used to evaluate the transcription phenotype of clustered base substitution mutations in the human rRNA promoter. The promoter consists of two major elements: a large upstream region, composed of several domains, that lies between nucleotides -234 and -107 relative to the transcription initiation site and affects transcription up to 100-fold and a core element that lies between nucleotides -45 and +20 and affects transcription up to 1000-fold. The upstream regions is able to retain partial function when positioned within 100-160 nucleotides of the transcription initiation site, but it cannot stimulate transcription from distances of ≥ 600 nucleotides. In addition, they demonstrate, using mouse-human hybrid rRNA promoters, that the sequences responsible for human species-specific transcription in vivo appear to reside in both the core and upstream elements, and sequences from the mouse rRNA promoter cannot be substituted for them

  19. Enhancer Analysis Unveils Genetic Interactions between TLX and SOX2 in Neural Stem Cells and In Vivo Reprogramming.

    Science.gov (United States)

    Islam, Mohammed M; Smith, Derek K; Niu, Wenze; Fang, Sanhua; Iqbal, Nida; Sun, Guoqiang; Shi, Yanhong; Zhang, Chun-Li

    2015-11-10

    The orphan nuclear receptor TLX is a master regulator of postnatal neural stem cell (NSC) self-renewal and neurogenesis; however, it remains unclear how TLX expression is precisely regulated in these tissue-specific stem cells. Here, we show that a highly conserved cis-element within the Tlx locus functions to drive gene expression in NSCs. We demonstrate that the transcription factors SOX2 and MYT1 specifically interact with this genomic element to directly regulate Tlx enhancer activity in vivo. Knockdown experiments further reveal that SOX2 dominantly controls endogenous expression of TLX, whereas MYT1 only plays a modulatory role. Importantly, TLX is essential for SOX2-mediated in vivo reprogramming of astrocytes and itself is also sufficient to induce neurogenesis in the adult striatum. Together, these findings unveil functional genetic interactions among transcription factors that are critical to NSCs and in vivo cell reprogramming.

  20. Neutron-activation analysis of trace elements in thyroids

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Petri, H.; Kanash, N.V.; Malenchenko, A.F.

    1999-01-01

    Neutron activation analysis was used for routine measurement of trace elements in thyroids of inhabitants of Belarus as well as in thyroids of people operated for thyroid cancer. The method chosen allowed the analysis of 28 elements, among them essential and toxic ones, with a good accuracy. The results obtained showed significant differences in the elemental composition of thyroid from the different regions. The changes of elemental composition of thyroids of inhabitants of the Gomel region, where goiter is endemic, seem to be identical to those in the tumor tissue. (author)

  1. Clinical applications of in vivo neutron-activation analysis

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1982-01-01

    In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into and modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, enhancing uniformity, and reducing the dose required for the measurement. The work presently underway will yield significant data on a variety of environmental contaminants such as Cd. Compositional studies are determining the level of vital constituents such as nitrogen and potassium in both normal subjects and in patients with a variety of metabolic disorders. Therapeutic programs can be assessed while in progress

  2. Advanced tools for in vivo skin analysis.

    Science.gov (United States)

    Cal, Krzysztof; Zakowiecki, Daniel; Stefanowska, Justyna

    2010-05-01

    A thorough examination of the skin is essential for accurate disease diagnostics, evaluation of the effectiveness of topically applied drugs and the assessment of the results of dermatologic surgeries such as skin grafts. Knowledge of skin parameters is also important in the cosmetics industry, where the effects of skin care products are evaluated. Due to significant progress in the electronics and computer industries, sophisticated analytic devices are increasingly available for day-to-day diagnostics. The aim of this article is to review several advanced methods for in vivo skin analysis in humans: magnetic resonance imaging, electron paramagnetic resonance, laser Doppler flowmetry and time domain reflectometry. The molecular bases of these techniques are presented, and several interesting applications in the field are discussed. Methods for in vivo assessment of the biomechanical properties of human skin are also reviewed.

  3. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  4. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Fischer, E.

    1976-05-01

    A neutron activation method for multielement determination in biological material was developed. The individual steps of the method include radiochemical processing as well as nondestructive techniques. In order to develop a high resolution gamma spectrometric method the indispensable assumptions were the application of Ge(Li)-semiconductor detectors, multi-channel pulse height analyzers and the use of electronic data evaluation with mini-computers for the automatic evaluation of complex gamma spectra. After radiochemical separation (RNAA) 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements is 4 days. The neutron activation method is used routinely for the determination of trace elements in foodstuffs and in the field of nutrition research. (orig.) [de

  5. Enhancer Analysis Unveils Genetic Interactions between TLX and SOX2 in Neural Stem Cells and In Vivo Reprogramming

    Science.gov (United States)

    Islam, Mohammed M.; Smith, Derek K.; Niu, Wenze; Fang, Sanhua; Iqbal, Nida; Sun, Guoqiang; Shi, Yanhong; Zhang, Chun-Li

    2015-01-01

    Summary The orphan nuclear receptor TLX is a master regulator of postnatal neural stem cell (NSC) self-renewal and neurogenesis; however, it remains unclear how TLX expression is precisely regulated in these tissue-specific stem cells. Here, we show that a highly conserved cis-element within the Tlx locus functions to drive gene expression in NSCs. We demonstrate that the transcription factors SOX2 and MYT1 specifically interact with this genomic element to directly regulate Tlx enhancer activity in vivo. Knockdown experiments further reveal that SOX2 dominantly controls endogenous expression of TLX, whereas MYT1 only plays a modulatory role. Importantly, TLX is essential for SOX2-mediated in vivo reprogramming of astrocytes and itself is also sufficient to induce neurogenesis in the adult striatum. Together, these findings unveil functional genetic interactions among transcription factors that are critical to NSCs and in vivo cell reprogramming. PMID:26607952

  6. Enhancer Analysis Unveils Genetic Interactions between TLX and SOX2 in Neural Stem Cells and In Vivo Reprogramming

    Directory of Open Access Journals (Sweden)

    Mohammed M. Islam

    2015-11-01

    Full Text Available The orphan nuclear receptor TLX is a master regulator of postnatal neural stem cell (NSC self-renewal and neurogenesis; however, it remains unclear how TLX expression is precisely regulated in these tissue-specific stem cells. Here, we show that a highly conserved cis-element within the Tlx locus functions to drive gene expression in NSCs. We demonstrate that the transcription factors SOX2 and MYT1 specifically interact with this genomic element to directly regulate Tlx enhancer activity in vivo. Knockdown experiments further reveal that SOX2 dominantly controls endogenous expression of TLX, whereas MYT1 only plays a modulatory role. Importantly, TLX is essential for SOX2-mediated in vivo reprogramming of astrocytes and itself is also sufficient to induce neurogenesis in the adult striatum. Together, these findings unveil functional genetic interactions among transcription factors that are critical to NSCs and in vivo cell reprogramming.

  7. Multi-element analysis of unidentified fallen objects from Tatale in ...

    African Journals Online (AJOL)

    A multi-element analysis has been carried out on two fallen objects, # 01 and # 02, using instrumental neutron activation analysis technique. A total of 17 elements were identified in object # 01 while 21 elements were found in object # 02. The two major elements in object # 01 were Fe and Mg, which together constitute ...

  8. Prompt and delay gamma ray measurements for 'in vivo' neutron activation analysis using a cyclic system

    International Nuclear Information System (INIS)

    Matthews, I.P.

    1979-09-01

    Early attempts at determining the elemental composition of the body by radioactive isotope dilution techniques are reviewed. The development and current status of in-vivo neutron activation analysis and the ways in which it supersedes or supplements certain of the former techniques are outlined. An irradiation facility is described which employs a 5 Ci neutron source and is capable of performing prompt and delay γ-ray measurements as well as cyclic activation. The uniformity of thermal neutron flux in a phantom is demonstrated and the neutron spectrum at a depth in the phantom has been obtained by means of threshold detectors. An examination is made of the possible applications of the Monte Carlo method to the design of irradiation and detection facilities and in yielding information about inaccessible areas. Detection limits for the bulk body elements and trace elements are presented. It is shown that the depth of a region of the body can be determined from a prompt gamma ray spectrum. This technique can be used to correct measurements when it is known that activation and detection is non-uniform. The feasibility of using a C.T. whole body scanner to measure bone demineralisation is explored. (author)

  9. Calibration procedures for in vivo sodium iodide spectrometry of plutonium and americium in the human lung

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Jett, J.H.

    1976-01-01

    This paper describes the calibration techniques and associated error analysis for the in vivo measurement by NaI spectrometry of heavy elements in the lung, specifically plutonium and americium. A very brief description of the instrumentation system is included

  10. Storage and pre-neutron-activation-analysis treatment for trace-element analysis in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.

    1985-01-01

    The problems regarding storage and pre-neutron-activation-analysis treatment for the elements aluminum, calcium, vanadium, selenium, copper, iodine, zinc, manganese, and magnesium in a urine matrix are reviewed. The type of collection and storage procedure and pre-neutron activation analysis treatment of urine depend on the specific trace element; that is, its inherent physical and chemical properties. Specifically polyethylene in teflon containers are the most suitable for general determinations. Whether any preservative is added would depend upon the stability of the trace element and its tendency for surface adsorption. Preferably, preservatives should contain no radioactivatable elements for maximum efficacy. Freeze drying or packing urine shipments under dry ice needs to be explored on an individual basis. Each pre- or post-neutron activation analysis treatment is specific and optimized for the trace element analyzed

  11. A Dual Super-Element Domain Decomposition Approach for Parallel Nonlinear Finite Element Analysis

    Science.gov (United States)

    Jokhio, G. A.; Izzuddin, B. A.

    2015-05-01

    This article presents a new domain decomposition method for nonlinear finite element analysis introducing the concept of dual partition super-elements. The method extends ideas from the displacement frame method and is ideally suited for parallel nonlinear static/dynamic analysis of structural systems. In the new method, domain decomposition is realized by replacing one or more subdomains in a "parent system," each with a placeholder super-element, where the subdomains are processed separately as "child partitions," each wrapped by a dual super-element along the partition boundary. The analysis of the overall system, including the satisfaction of equilibrium and compatibility at all partition boundaries, is realized through direct communication between all pairs of placeholder and dual super-elements. The proposed method has particular advantages for matrix solution methods based on the frontal scheme, and can be readily implemented for existing finite element analysis programs to achieve parallelization on distributed memory systems with minimal intervention, thus overcoming memory bottlenecks typically faced in the analysis of large-scale problems. Several examples are presented in this article which demonstrate the computational benefits of the proposed parallel domain decomposition approach and its applicability to the nonlinear structural analysis of realistic structural systems.

  12. Correct use of Membrane Elements in Structural Analysis

    Directory of Open Access Journals (Sweden)

    Rothman Timothy

    2016-01-01

    Full Text Available Structural analysis of consumer electronic devices such as phones and tablets involves Finite Element Analysis (FEA. Dynamic loading conditions such as device dropping and bending dictate accurate FEA models to reduce design risk in many areas. The solid elements typically used in structural analysis do not have integration points on the surface. The outer surface is of most interest because that is where the cracks start. Analysts employ a post processing trick through using membranes to bring accurate stress/strain results to the surface. This paper explains numerical issues with implementation of membranes and recommends a methodology for accurate structural analysis.

  13. Combined in vivo and ex vivo analysis of mesh mechanics in a porcine hernia model.

    Science.gov (United States)

    Kahan, Lindsey G; Lake, Spencer P; McAllister, Jared M; Tan, Wen Hui; Yu, Jennifer; Thompson, Dominic; Brunt, L Michael; Blatnik, Jeffrey A

    2018-02-01

    Hernia meshes exhibit variability in mechanical properties, and their mechanical match to tissue has not been comprehensively studied. We used an innovative imaging model of in vivo strain tracking and ex vivo mechanical analysis to assess effects of mesh properties on repaired abdominal walls in a porcine model. We hypothesized that meshes with dissimilar mechanical properties compared to native tissue would alter abdominal wall mechanics more than better-matched meshes. Seven mini-pigs underwent ventral hernia creation and subsequent open repair with one of two heavyweight polypropylene meshes. Following mesh implantation with attached radio-opaque beads, fluoroscopic images were taken at insufflation pressures from 5 to 30 mmHg on postoperative days 0, 7, and 28. At 28 days, animals were euthanized and ex vivo mechanical testing performed on full-thickness samples across repaired abdominal walls. Testing was conducted on 13 mini-pig controls, and on meshes separately. Stiffness and anisotropy (the ratio of stiffness in the transverse versus craniocaudal directions) were assessed. 3D reconstructions of repaired abdominal walls showed stretch patterns. As pressure increased, both meshes expanded, with no differences between groups. Over time, meshes contracted 17.65% (Mesh A) and 0.12% (Mesh B; p = 0.06). Mesh mechanics showed that Mesh A deviated from anisotropic native tissue more than Mesh B. Compared to native tissue, Mesh A was stiffer both transversely and craniocaudally. Explanted repaired abdominal walls of both treatment groups were stiffer than native tissue. Repaired tissue became less anisotropic over time, as mesh properties prevailed over native abdominal wall properties. This technique assessed 3D stretch at the mesh level in vivo in a porcine model. While the abdominal wall expanded, mesh-ingrown areas contracted, potentially indicating stresses at mesh edges. Ex vivo mechanics demonstrate that repaired tissue adopts mesh properties, suggesting

  14. Elemental analysis: Reduction to SI units; Rueckfuehrung in der Elementanalytik

    Energy Technology Data Exchange (ETDEWEB)

    Rienitz, O.; Jaehrling, R.; Schiel, D. [PTB-Arbeitsgruppe ' ' Anorganische Analytik' ' , Braunschweig (Germany); Matschat, R.; Kipphardt, H. [Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Gernand, W.; Oeter, D. [MercK KGaA (Germany)

    2005-12-15

    In a joint project, PTB, BAM and Merck KGaA worked on a metrological reduction system for all elements relevant to analysis. The BAM certified primary pure substances with a relative error of U{sub rel} {<=} 0.01% for the mass of the main element. This was achieved by measuring the mass components of all potential impurities, i.e. practically all elements of the periodic system except the main element. These pure substances are the national reference standards of elemental analysis. From them, PTB produces primary elementa solutions and transfer solutions which are passed on as reference standards. The industrial partner constructed the DKD calibration laboratory, which certifies commercial secondary calibration solutions on the basis of the reference standard solutions produced by PTB. With this final product, measurements in elemental analysis can be reduced to the SI units system as a routine procedure. (orig.)

  15. In vivo energy dispersive X-ray fluorescence for measuring the content of essential and toxic trace elements in teeth

    International Nuclear Information System (INIS)

    Zaichick, V.; Ovchjarenko, N.; Zaichick, S.

    1999-01-01

    The calibration and application of a facility, based on energy dispersive X-ray fluorescent analysis (EDXRF) using 109 Cd as an excitation source, for in vivo and in vitro estimation of Ca, Pb, Sr and Zn in tooth enamel is described. During the in vivo measurements, the device ensures tissue protection of face and mouth cavity from radiation, and only a small part of tooth surface under study is irradiated. To calibrate the facility, the contents of Ca, Sr and Zn were analyzed simultaneously in the enamel of 50 teeth by EDXRF and instrumental neutron activation analysis (INAA). Standards prepared from powdered tooth enamel with additions of chemically pure lead compounds were used to calibrate for lead graduation. Enamel calcium is suggested as an internal standard during in vivo EDXRF of teeth. The content of enamel Sr, Zn and Pb was determined by EDXRF in 35 permanent intact teeth of teenagers and adults. It was shown that lead concentration didn't exceed 3 μg/g for all the teeth

  16. Embryonic lineage analysis using three-dimensional, time-lapse in-vivo fluorescent microscopy

    Science.gov (United States)

    Minden, Jonathan; Kam, Zvi; Agard, David A.; Sedat, John W.; Alberts, Bruce

    1990-08-01

    Drosophila melanogaster has become one of the most extensively studied organisms because of its amenability to genetic analysis. Unfortunately, the biochemistry and cell biology ofDrosophila has lagged behind. To this end we have been microinjecting fluorescently labelled proteins into the living embryo and observing the behavior of these proteins to determine their role in the cell cycle and development. Imaging of these fluorescent probes is an extremely important element to this form of analysis. We have taken advantage of the sensitivity and well behaved characteristics of the charge coupled device (CCD) camera in conjunction with digital image enhancement schemes to produce highly accurate images of these fluorescent probes in vivo. One of our major goals is to produce a detailed map of cell fate so that we can understand how fate is determined and maintained. In order produce such a detailed map, protocols for following the movements and mitotic behavior of a large number of cells in three dimensions over relatively long periods of time were developed. We will present our results using fluorescently labelled histone proteins as a marker for nuclear location1. In addition, we will also present our initial results using a photoactivatable analog of fluorescein to mark single cells so that their long range fate can be unambiguously determined.

  17. Chemical analysis of useful trace elements in sea water

    International Nuclear Information System (INIS)

    Katoh, Shunsaku; Fujii, Ayako; Miyai, Yoshitaka; Sakane, Kohji; Ogata, Noboru.

    1983-01-01

    The methods for the analysis of useful trace elements in sea water which have been tried so far are reviewed, and these methods are described briefly from the standpoint of studying the collection of resources. Ag and Au can be determined by concentrating sea water by ion-exchange method, solvent extraction method and electrodeposition method, then the elements are measured quantitatively by activation analysis and atomic absorption spectrochemical analysis. Sr, B and Li, which exist in relatively high concentration in sea water, are determined easily by atomic absorption spectrochemical analysis and absorption spectrometry. U, Mo and V are measured suitably by concentrating the elements by coprecipitation or solvent extraction method, and measuring by fluorescence analysis and arsenazo-3 method for U and through graphite-atomic absorption analysis for Mo and V. It has been revealed that the concentration of Ag and Au in sea water is extremely low, accordingly the recovery study is not conducted recently. On the other hand, the adsorption method using hydrated titanium oxide and amidoxim adsorbents for U, Mo and V, the adsorption method using aluminum adsorbent for Li, and the adsorption method using magnesium oxide and zirconium hydroxide and the solvent extraction method for B are hopeful to recover these elements. (Yoshitake, I.)

  18. Optical selection of trace elements for discriminant analysis

    International Nuclear Information System (INIS)

    Rasmussen, S.E.; Erasmus, C.S.; Watterson, J.I.W.; Sellschop, J.P.F.

    This report describes different methods of element selection; a combination of stepwise multivariate analysis of variance for primary element selection, and principle component analysis regression for the element interrelationship analysis. These offer a satisfactory solution to the problem of element selection

  19. In vivo bone strain and finite-element modeling of the craniofacial haft in catarrhine primates

    Science.gov (United States)

    Ross, Callum F; Berthaume, Michael A; Dechow, Paul C; Iriarte-Diaz, Jose; Porro, Laura B; Richmond, Brian G; Spencer, Mark; Strait, David

    2011-01-01

    Hypotheses regarding patterns of stress, strain and deformation in the craniofacial skeleton are central to adaptive explanations for the evolution of primate craniofacial form. The complexity of craniofacial skeletal morphology makes it difficult to evaluate these hypotheses with in vivo bone strain data. In this paper, new in vivo bone strain data from the intraorbital surfaces of the supraorbital torus, postorbital bar and postorbital septum, the anterior surface of the postorbital bar, and the anterior root of the zygoma are combined with published data from the supraorbital region and zygomatic arch to evaluate the validity of a finite-element model (FEM) of a macaque cranium during mastication. The behavior of this model is then used to test hypotheses regarding the overall deformation regime in the craniofacial haft of macaques. This FEM constitutes a hypothesis regarding deformation of the facial skeleton during mastication. A simplified verbal description of the deformation regime in the macaque FEM is as follows. Inferior bending and twisting of the zygomatic arches about a rostrocaudal axis exerts inferolaterally directed tensile forces on the lateral orbital wall, bending the wall and the supraorbital torus in frontal planes and bending and shearing the infraorbital region and anterior zygoma root in frontal planes. Similar deformation regimes also characterize the crania of Homo and Gorilla under in vitro loading conditions and may be shared among extant catarrhines. Relatively high strain magnitudes in the anterior root of the zygoma suggest that the morphology of this region may be important for resisting forces generated during feeding. PMID:21105871

  20. Feasibility of measuring selenium in humans using in vivo neutron activation analysis.

    Science.gov (United States)

    Tahir, S N A; Chettle, D R; Byun, S H; Prestwich, W V

    2015-11-01

    Selenium (Se) is an element that, in trace quantities, plays an important role in the normal function of a number of biological processes in humans. Many studies have demonstrated that selenium deficiency in the body may contribute to an increased risk for certain neoplastic, cardiovascular, osseous, and nervous system diseases including retardation of bone formation. However, at higher concentrations Se is cytotoxic. For these reasons it is desirable to have a means of monitoring selenium concentration in humans.This paper presents the outcome of a feasibility study carried out for measuring selenium in humans using in vivo neutron activation analysis (IVNAA). In this technique a small dose of neutrons is delivered to the organ of interest, the neutrons are readily captured by the target nuclei, and the γ-rays given off are detected outside of the body. For the present study, human hand (bone) tissue equivalent phantoms were prepared with varying amounts of Se. These were irradiated by a low energy fast neutron beam produced by the (7)Li(p,n)(7)Be reaction employing the high beam current Tandetron accelerator. The counting data saved using a 4π NaI(TI) detection system were analyzed. The selenium was detected via the neutron capture reaction, (76)Se(n,γ)(77 m)Se, whereas calcium was detected through the (48)Ca(n,γ)(49)Ca reaction for the purpose of normalization of the Se signals to the calcium signals. From the calibration lines drawn between Se/Ca concentrations and Se/Ca counts ratio, the minimum detection limits (MDLs) were computed for two sets of phantoms irradiated under different irradiation parameters.In this study the optimized MDL value was determined to be 81 ng g(-1) (Se/phantom mass) for an equivalent dose of 188 mSv to the phantom. This MDL was found at least 10 times lower than the reported data on Se concentration measured in bone tissues. It was concluded that the NAA technique would be a feasible means of performing in vivo measurements of

  1. Chemical analysis of rare earth elements

    International Nuclear Information System (INIS)

    Tsukahara, Ryoichi; Sakoh, Takefumi; Nagai, Iwao

    1994-01-01

    Recently attention has been paid to ICP-AES or ICP-MS, and the reports on the analysis of rare earth elements by utilizing these methods continue to increase. These reports have become to take about 30% of the reports on rare earth analysis, and this is because these methods are highly sensitive to rare earth elements, and also these methods have spread widely. In ICP-AES and ICP-MS, mostly solution samples are measured, therefore, solids must be made into solution. At the time of quantitatively determining the rare earth elements of low concentration, separation and concentration are necessary. Referring to the literatures reported partially in 1990 and from 1991 to 1993, the progress of ICP-AES and ICP-MS is reported. Rare earth oxides and the alloys containing rare earth elements are easily decomposed with acids, but the decomposition of rocks is difficult, and its method is discussed. The separation of the rare earth elements from others in geochemical samples, cation exchange process is frequently utilized. Also solvent extraction process has been studied. For the separation of rare earth elements mutually, chromatography is used. The spectral interference in spectral analysis was studied. The comparison of these methods with other methods is reported. (K.I)

  2. Disappearance of nucleosome positioning in mitotic chromatin in vivo.

    Science.gov (United States)

    Komura, Jun-ichiro; Ono, Tetsuya

    2005-04-15

    During mitosis, transcription is silenced and most transcription factors are displaced from their recognition sequences. By in vivo footprinting analysis, we have confirmed and extended previous studies showing loss of transcription factors from an RNA polymerase II promoter (c-FOS) and, for the first time, an RNA polymerase III promoter (U6) in HeLa cells. Because little was known about nucleosomal organization in mitotic chromosomes, we performed footprinting analysis for nucleosomes on these promoters in interphase and mitotic cells. During interphase, each of the promoters had a positioned nucleosome in the region intervening between proximal promoter elements and distal enhancer elements, but the strong nucleosome positioning disappeared during mitosis. Thus, the nucleosomal organization that appears to facilitate transcription in interphase cells may be lost in mitotic cells, and nucleosome positioning during mitosis does not seem to be a major component of the epigenetic mechanisms to mark genes for rapid reactivation after this phase.

  3. A finite element model for protein transport in vivo

    Directory of Open Access Journals (Sweden)

    Montas Hubert J

    2007-06-01

    Full Text Available Abstract Background Biological mass transport processes determine the behavior and function of cells, regulate interactions between synthetic agents and recipient targets, and are key elements in the design and use of biosensors. Accurately predicting the outcomes of such processes is crucial to both enhancing our understanding of how these systems function, enabling the design of effective strategies to control their function, and verifying that engineered solutions perform according to plan. Methods A Galerkin-based finite element model was developed and implemented to solve a system of two coupled partial differential equations governing biomolecule transport and reaction in live cells. The simulator was coupled, in the framework of an inverse modeling strategy, with an optimization algorithm and an experimental time series, obtained by the Fluorescence Recovery after Photobleaching (FRAP technique, to estimate biomolecule mass transport and reaction rate parameters. In the inverse algorithm, an adaptive method was implemented to calculate sensitivity matrix. A multi-criteria termination rule was developed to stop the inverse code at the solution. The applicability of the model was illustrated by simulating the mobility and binding of GFP-tagged glucocorticoid receptor in the nucleoplasm of mouse adenocarcinoma. Results The numerical simulator shows excellent agreement with the analytic solutions and experimental FRAP data. Detailed residual analysis indicates that residuals have zero mean and constant variance and are normally distributed and uncorrelated. Therefore, the necessary and sufficient criteria for least square parameter optimization, which was used in this study, were met. Conclusion The developed strategy is an efficient approach to extract as much physiochemical information from the FRAP protocol as possible. Well-posedness analysis of the inverse problem, however, indicates that the FRAP protocol provides insufficient

  4. Analysis of trace elements in serum from human eating irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi; Chen Shijie; Gao Sumei

    1987-01-01

    A method of trace element analysis by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AEC) in serum from human eating food preserved by irradiation is described. Trace element analysis in human serum is one of the research projects concerning the wholesomeness. 78 serum samples of the human eating food preserved by irradiation were collected. After ashing and solving ICP-AES analysis of serum is performed for detecting 12 trace elements in specimen solution. The detection limitations are in the range of 10 -2 - 10 -3 ppm for differemt elements. The recoveries of elements are over 73%. Concentrations of 12 trace elements in 78 human serum has been calculated with F and t tests at PDP 11/70 computer and it was concluded that there is no significant difference between testing group and control group

  5. Finite element analysis theory and application with ANSYS

    CERN Document Server

    Moaveni, Saeed

    2015-01-01

    For courses in Finite Element Analysis, offered in departments of Mechanical or Civil and Environmental Engineering. While many good textbooks cover the theory of finite element modeling, Finite Element Analysis: Theory and Application with ANSYS is the only text available that incorporates ANSYS as an integral part of its content. Moaveni presents the theory of finite element analysis, explores its application as a design/modeling tool, and explains in detail how to use ANSYS intelligently and effectively. Teaching and Learning Experience This program will provide a better teaching and learning experience-for you and your students. It will help: *Present the Theory of Finite Element Analysis: The presentation of theoretical aspects of finite element analysis is carefully designed not to overwhelm students. *Explain How to Use ANSYS Effectively: ANSYS is incorporated as an integral part of the content throughout the book. *Explore How to Use FEA as a Design/Modeling Tool: Open-ended design problems help stude...

  6. Elemental analysis with external-beam PIXE

    Science.gov (United States)

    Lin, E. K.; Wang, C. W.; Teng, P. K.; Huang, Y. M.; Chen, C. Y.

    1992-05-01

    A beamline system and experimental setup has been established for elemental analysis using PIXE with an external beam. Experiments for the study of the elemental composition of ancient Chinese potsherds (the Min and Ching ages) were performed. Continuum X-ray spectra from the samples bombarded by 3 MeV protons have been measured with a Si(Li) detector. From the analysis of PIXE data, the concentration of the main elements (Al, Si, K, and Ca) and of more than ten trace elements in the matrices and glazed surfaces were determined. Results for two different potsherds are presented, and those obtained from the glaze colorants are compared with the results of measurements on a Ching blue-and-white porcelain vase.

  7. Instrumental trace element analysis of California market milk

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Langhorst, A.L.; Ralston, H.R.; Heft, R.

    1975-01-01

    Trace element analysis for 15 elements (Zn, Na, Br, Rb, Sr, Mg, Al, Ca, Cl, I, K, Fe, Co, Se, Cs) was carried out on 32 samples of California market milk and 6 samples of Colorado milk in a pilot study of toxic and nutrient trace elements in the soil-forage-cow-milk food chain. The techniques of instrumental neutron activation analysis and x-ray fluorescence analysis are described. Sample collection, preparation, analysis, and data reduction procedures are discussed. The mean values and variations of trace element concentrations in milk are compared to data from other studies. (U.S.)

  8. Finite element analysis of piezoelectric materials

    International Nuclear Information System (INIS)

    Lowrie, F.; Stewart, M.; Cain, M.; Gee, M.

    1999-01-01

    This guide is intended to help people wanting to do finite element analysis of piezoelectric materials by answering some of the questions that are peculiar to piezoelectric materials. The document is not intended as a complete beginners guide for finite element analysis in general as this is better dealt with by the individual software producers. The guide is based around the commercial package ANSYS as this is a popular package amongst piezoelectric material users, however much of the information will still be useful to users of other finite element codes. (author)

  9. Optimized isolation enables Ex vivo analysis of microglia from various central nervous system regions

    NARCIS (Netherlands)

    De Haas, Alexander H.; Boddeke, Hendricus W. G. M.; Brouwer, Nieske; Biber, Knut

    2007-01-01

    Ex vivo analysis is an accurate and convenient way to study in vivo microglia phenotype and function. However, current microglia isolation protocols for ex vivo analysis show many differences in isolation steps (perfusion, removal of meninges and blood vessels, mechanical dissociation, enzymatic

  10. A compact, in vivo screen of all 6-mers reveals drivers of tissue-specific expression and guides synthetic regulatory element design.

    Science.gov (United States)

    Smith, Robin P; Riesenfeld, Samantha J; Holloway, Alisha K; Li, Qiang; Murphy, Karl K; Feliciano, Natalie M; Orecchia, Lorenzo; Oksenberg, Nir; Pollard, Katherine S; Ahituv, Nadav

    2013-07-18

    Large-scale annotation efforts have improved our ability to coarsely predict regulatory elements throughout vertebrate genomes. However, it is unclear how complex spatiotemporal patterns of gene expression driven by these elements emerge from the activity of short, transcription factor binding sequences. We describe a comprehensive promoter extension assay in which the regulatory potential of all 6 base-pair (bp) sequences was tested in the context of a minimal promoter. To enable this large-scale screen, we developed algorithms that use a reverse-complement aware decomposition of the de Bruijn graph to design a library of DNA oligomers incorporating every 6-bp sequence exactly once. Our library multiplexes all 4,096 unique 6-mers into 184 double-stranded 15-bp oligomers, which is sufficiently compact for in vivo testing. We injected each multiplexed construct into zebrafish embryos and scored GFP expression in 15 tissues at two developmental time points. Twenty-seven constructs produced consistent expression patterns, with the majority doing so in only one tissue. Functional sequences are enriched near biologically relevant genes, match motifs for developmental transcription factors, and are required for enhancer activity. By concatenating tissue-specific functional sequences, we generated completely synthetic enhancers for the notochord, epidermis, spinal cord, forebrain and otic lateral line, and show that short regulatory sequences do not always function modularly. This work introduces a unique in vivo catalog of short, functional regulatory sequences and demonstrates several important principles of regulatory element organization. Furthermore, we provide resources for designing compact, reverse-complement aware k-mer libraries.

  11. Diode In-vivo Dosimetry for External Beam Radiotherapy: Patient Data Analysis

    International Nuclear Information System (INIS)

    Mrcela, I.; Bokulic, T.; Budanec, M; Froebe, A.; Soldic, Z.; Kusic, Z.

    2008-01-01

    In-vivo dosimetry is known as simple and reliable method for checking the final accuracy of the dose delivered in external radiotherapy making a supplement to the regular quality control. Entrance dose measurements in the beginning of the treatment assure detection of major errors that can affect the therapy outcome. Silicon diodes are often the detectors of choice for their ability of real time dose measurements and the simplicity of use. There are many publications describing the procedures for the implementation of in-vivo dosimetry. Routine in-vivo dosimetry has been introduced in our department after initial procedures including physical characterization, calibration and determination of correction factors for the detectors in use. This work presents patient data analysis with more than 700 field measurements taken in last 2 years period

  12. Neutron activation analysis of trace elements in IAEA reference materials

    International Nuclear Information System (INIS)

    Cheema, M.N.; Hasany, S.M.; Hanif, I.; Chaudhry, M.S.; Qureshi, I.H.

    1978-09-01

    Analytical Chemistry Group of Nuclear Chemistry Division at PINSTECH has been participating in IAEA Intercomparison programme of analytical quality control since 1972. So far fifteen samples of a variety of materials received from the Agency have been analyzed for different minor and trace elements. Mostly destructive and non-destructive neutron activation analysis techniques have been used for elemental analysis. In this report the description of the samples and the experimental procedures employed have been mentioned. The results of elemental analysis have been reported and compared with IAEA values which are based on the average computed from the results of different participating laboratories. (authors)

  13. Dynamic relaxation method in analysis of reinforced concrete bent elements

    Directory of Open Access Journals (Sweden)

    Anna Szcześniak

    2015-12-01

    Full Text Available The paper presents a method for the analysis of nonlinear behaviour of reinforced concrete bent elements subjected to short-term static load. The considerations in the range of modelling of deformation processes of reinforced concrete element were carried out. The method of structure effort analysis was developed using the finite difference method. The Dynamic Relaxation Method, which — after introduction of critical damping — allows for description of the static behaviour of a structural element, was used to solve the system of nonlinear equilibrium equations. In order to increase the method effectiveness in the range of the post-critical analysis, the Arc Length Parameter on the equilibrium path was introduced into the computational procedure.[b]Keywords[/b]: reinforced concrete elements, physical nonlinearity, geometrical nonlinearity, dynamic relaxation method, arc-length method

  14. Comparative Study on Interface Elements, Thin-Layer Elements, and Contact Analysis Methods in the Analysis of High Concrete-Faced Rockfill Dams

    Directory of Open Access Journals (Sweden)

    Xiao-xiang Qian

    2013-01-01

    Full Text Available This paper presents a study on the numerical performance of three contact simulation methods, namely, the interface element, thin-layer element, and contact analysis methods, through the analysis of the contact behavior between the concrete face slab and the dam body of a high concrete-faced rockfill dam named Tianshengqiao-I in China. To investigate the accuracy and limitations of each method, the simulation results are compared in terms of the dam deformation, contact stress along the interface, stresses in the concrete face slab, and separation of the concrete face slab from the cushion layer. In particular, the predicted dam deformation and slab separation are compared with the in-situ observation data to classify these methods according to their agreement with the in-situ observations. It is revealed that the interface element and thin-layer element methods have their limitations in predicting contact stress, slab separation, and stresses in the concrete face slab if a large slip occurs. The contact analysis method seems to be the best choice whether the separation is finite or not.

  15. Why do probabilistic finite element analysis ?

    CERN Document Server

    Thacker, Ben H

    2008-01-01

    The intention of this book is to provide an introduction to performing probabilistic finite element analysis. As a short guideline, the objective is to inform the reader of the use, benefits and issues associated with performing probabilistic finite element analysis without excessive theory or mathematical detail.

  16. [Principal component analysis and cluster analysis of inorganic elements in sea cucumber Apostichopus japonicus].

    Science.gov (United States)

    Liu, Xiao-Fang; Xue, Chang-Hu; Wang, Yu-Ming; Li, Zhao-Jie; Xue, Yong; Xu, Jie

    2011-11-01

    The present study is to investigate the feasibility of multi-elements analysis in determination of the geographical origin of sea cucumber Apostichopus japonicus, and to make choice of the effective tracers in sea cucumber Apostichopus japonicus geographical origin assessment. The content of the elements such as Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Hg and Pb in sea cucumber Apostichopus japonicus samples from seven places of geographical origin were determined by means of ICP-MS. The results were used for the development of elements database. Cluster analysis(CA) and principal component analysis (PCA) were applied to differentiate the sea cucumber Apostichopus japonicus geographical origin. Three principal components which accounted for over 89% of the total variance were extracted from the standardized data. The results of Q-type cluster analysis showed that the 26 samples could be clustered reasonably into five groups, the classification results were significantly associated with the marine distribution of the sea cucumber Apostichopus japonicus samples. The CA and PCA were the effective methods for elements analysis of sea cucumber Apostichopus japonicus samples. The content of the mineral elements in sea cucumber Apostichopus japonicus samples was good chemical descriptors for differentiating their geographical origins.

  17. Application of trace element analysis to determine trace element concentrations in the field of medicine

    International Nuclear Information System (INIS)

    Kasperek, K.; Feinendegen, L.E.

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis such as, e.g., neutron activation analysis. Essential trace elements act as stabilisators (iron in haem), structural elements (silicium in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalysators. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection. (orig./AK) [de

  18. Phytochemical screening, proximate and elemental analysis of ...

    African Journals Online (AJOL)

    Citrus sinensis was screened for its phytochemical composition and was evaluated for the proximate and elemental analysis. The phytochemical analysis indicated the presence of reducing sugar, saponins, cardiac glycosides, tannins and flavonoids. The elemental analysis indicated the presence of the following mineral ...

  19. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  20. Finite Element Analysis of Pipe T-Joint

    OpenAIRE

    P.M.Gedkar; Dr. D.V. Bhope

    2012-01-01

    This paper reports stress analysis of two pressurized cylindrical intersection using finite element method. The different combinations of dimensions of run pipe and the branch pipe are used to investigate thestresses in pipe at the intersection. In this study the stress analysis is accomplished by finite element package ANSYS.

  1. Finite element analysis of inclined nozzle-plate junctions

    International Nuclear Information System (INIS)

    Dixit, K.B.; Seth, V.K.; Krishnan, A.; Ramamurthy, T.S.; Dattaguru, B.; Rao, A.K.

    1979-01-01

    Estimation of stress concentration at nozzle to plate or shell junctions is a significant problem in the stress analysis of nuclear reactors. The topic is a subject matter of extensive investigations and earlier considerable success has been reported on analysis for the cases when the nozzle is perpendicular to the plate or is radial to the shell. Analytical methods for the estimation of stress concentrations for the practical situations when the intersecting nozzle is inclined to the plate or is non-radial to the shell is rather scanty. Specific complications arise in dealing with the junction region when the nozzle with circular cross-section meets the non-circular cut-out on the plate or shell. In this paper a finite element analysis is developed for inclined nozzles and results are presented for nozzle-plate junctions. A method of analysis is developed with a view to achieving simultaneously accuracy of results and simplicity in the choice of elements and their connectivity. The circular nozzle is treated by axisymmetric conical shell elements. The nozzle portion in the region around the junction and the flat plate is dealt with by triangular flat shell elements. Special transition elements are developed for joining the flat shell elements with the axisymmetric elements under non-axisymmetric loading. A substructure method of analysis is adopted which achieves considerable economy in handling the structure and also conveniently combines the different types of elements in the structure. (orig.)

  2. In vivo prompt gamma activation analysis facility for total body nitrogen and cadmium

    International Nuclear Information System (INIS)

    Munive, Marco; Solis, Jose; Revilla, Angel

    2008-01-01

    Full text: Prompt Neutron Activation Analysis (PGNAA) is a technique that could have medical applications, like determination of body's contents of protein and heavy metals in vivo. The in vivo PGNAA facility, contains a neutron source (Cf-252) with safety device, a compartment for animal irradiation, and a gamma rays detecting system based on the NaI(Tl) detector with an analytical software. The prompt gamma rays were emitted after 10 -15 s of the interaction, so they don't produce radioactive waste, and have a characteristics energy for each element, i.e. a strong peak at 2.24 MeV is observed for H. The facility has been used with laboratory mice. Water-filled phantom placed in the neutron beam was used to system calibration. Three study groups of 5 mice each one were selected and were feed with a different diet and the total body nitrogen (TBN) of the mice was monitored with the facility. The diet produced a different TBN for each group. Some mice drunk diluted water with Cl 2 Cd, so the presence of Cd was detected in the mouse. The minimum Cd concentration that the system can detect was 20 ppm. The total dose (neutron and gamma dose was measured from TLDs and simulated by MNCP-4B in the sample compartment during the irradiation time (5 minutes) is less than 2.5 mSv. This total dose is low than the dose from other analytical radiological techniques (25 a 50 mSv). (author)

  3. Application of activation analysis for determination of some elements in cassiterite samples

    International Nuclear Information System (INIS)

    Armelin, Maria Jose Aguirre

    1978-01-01

    This work consists in the development of an analytical method using activation by thermal neutrons for the determination of some minor elements and traces present in cassiterite (tin ore). This method was then applied to determine these elements in samples of cassiterite from different regions of Brazil. An analysis was made of the mineralogy characteristic of cassiterite as well as of the minerals most commonly associated with it. Four main types of interference were found to occur in the analysis by activation of trace elements in samples of cassiterite. The method involves the analysis without chemical separation for the determination of some elements and the analysis with chemical separation for the determination of other elements. The steps involved in both types of analysis are described. In the analysis with chemical separation the matrix element (tin) is separated by distillation in an H 2 SO 4 -HBr medium, after fusion of the ore with Na 2 O 2 . Arsine and antimony are determined in the distilled, whereas some lanthanide elements and uranium are determined in the distillation residue by separating them as a group by precipitation with lanthanum fluoride. A discussion on the precision, accuracy and sensibility of the method is also included. (author)

  4. Probabilistic finite elements for transient analysis in nonlinear continua

    Science.gov (United States)

    Liu, W. K.; Belytschko, T.; Mani, A.

    1985-01-01

    The probabilistic finite element method (PFEM), which is a combination of finite element methods and second-moment analysis, is formulated for linear and nonlinear continua with inhomogeneous random fields. Analogous to the discretization of the displacement field in finite element methods, the random field is also discretized. The formulation is simplified by transforming the correlated variables to a set of uncorrelated variables through an eigenvalue orthogonalization. Furthermore, it is shown that a reduced set of the uncorrelated variables is sufficient for the second-moment analysis. Based on the linear formulation of the PFEM, the method is then extended to transient analysis in nonlinear continua. The accuracy and efficiency of the method is demonstrated by application to a one-dimensional, elastic/plastic wave propagation problem. The moments calculated compare favorably with those obtained by Monte Carlo simulation. Also, the procedure is amenable to implementation in deterministic FEM based computer programs.

  5. Elemental misinterpretation in automated analysis of LIBS spectra.

    Science.gov (United States)

    Hübert, Waldemar; Ankerhold, Georg

    2011-07-01

    In this work, the Stark effect is shown to be mainly responsible for wrong elemental allocation by automated laser-induced breakdown spectroscopy (LIBS) software solutions. Due to broadening and shift of an elemental emission line affected by the Stark effect, its measured spectral position might interfere with the line position of several other elements. The micro-plasma is generated by focusing a frequency-doubled 200 mJ pulsed Nd/YAG laser on an aluminum target and furthermore on a brass sample in air at atmospheric pressure. After laser pulse excitation, we have measured the temporal evolution of the Al(II) ion line at 281.6 nm (4s(1)S-3p(1)P) during the decay of the laser-induced plasma. Depending on laser pulse power, the center of the measured line is red-shifted by 130 pm (490 GHz) with respect to the exact line position. In this case, the well-known spectral line positions of two moderate and strong lines of other elements coincide with the actual shifted position of the Al(II) line. Consequently, a time-resolving software analysis can lead to an elemental misinterpretation. To avoid a wrong interpretation of LIBS spectra in automated analysis software for a given LIBS system, we recommend using larger gate delays incorporating Stark broadening parameters and using a range of tolerance, which is non-symmetric around the measured line center. These suggestions may help to improve time-resolving LIBS software promising a smaller probability of wrong elemental identification and making LIBS more attractive for industrial applications.

  6. Scanning Electron Microscope-Cathodoluminescence Analysis of Rare-Earth Elements in Magnets.

    Science.gov (United States)

    Imashuku, Susumu; Wagatsuma, Kazuaki; Kawai, Jun

    2016-02-01

    Scanning electron microscope-cathodoluminescence (SEM-CL) analysis was performed for neodymium-iron-boron (NdFeB) and samarium-cobalt (Sm-Co) magnets to analyze the rare-earth elements present in the magnets. We examined the advantages of SEM-CL analysis over conventional analytical methods such as SEM-energy-dispersive X-ray (EDX) spectroscopy and SEM-wavelength-dispersive X-ray (WDX) spectroscopy for elemental analysis of rare-earth elements in NdFeB magnets. Luminescence spectra of chloride compounds of elements in the magnets were measured by the SEM-CL method. Chloride compounds were obtained by the dropwise addition of hydrochloric acid on the magnets followed by drying in vacuum. Neodymium, praseodymium, terbium, and dysprosium were separately detected in the NdFeB magnets, and samarium was detected in the Sm-Co magnet by the SEM-CL method. In contrast, it was difficult to distinguish terbium and dysprosium in the NdFeB magnet with a dysprosium concentration of 1.05 wt% by conventional SEM-EDX analysis. Terbium with a concentration of 0.02 wt% in an NdFeB magnet was detected by SEM-CL analysis, but not by conventional SEM-WDX analysis. SEM-CL analysis is advantageous over conventional SEM-EDX and SEM-WDX analyses for detecting trace rare-earth elements in NdFeB magnets, particularly dysprosium and terbium.

  7. In-vivo neutron activation analysis: principles and clinical applications

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1982-01-01

    In vivo neutron activation has opened a new era of both clinical diagnosis and therapy evaluation, and investigation into and modelling of body composition. The techniques are new, but it is already clear that considerable strides can be made in increasing accuracy and precision, increasing the number of elements susceptible to measurement, enhancing uniformity, and reducing the dose required for the measurement. The work presently underway will yield significant data on a variety of environmental contaminants such as Cd. Compositional studies are determining the level of vital constituents such as nitrogen and potassium in both normal subjects and in patients with a variety of metabolic disorders. Therapeutic programs can be assessed while in progress. It seems likely that by the end of this century there will have been significant progress with this research tool, and exciting insights obtained into the nature and dynamics of human body composition

  8. Application of trace element analysis to determine trace element concentrations in the field of medicine. [Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kasperek, K; Feinendegen, L E

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis, such as neutron activation analysis. Essential trace elements act as stabilizators (iron in haem), structural elements (silicon in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalyzers. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection.

  9. Determination of mutually interfering elements in activation analysis

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.

    1979-01-01

    The determination of the elements present in the groups scandium-zinc, mercury-selenium and arsenic-antimony-bromine represents a classical problem in thermal neutron activation analysis because the gamma-ray peaks of the radioisotopes produced from these elements by activation appear very close in the spectrum. A study is made of the possibility of simultaneous instrumental determination of these elements by means of the spectrum stripping technique, using a 400-channel analyser coupled to a Nal(Tl) detector and a 4096-channel analyser coupled to a Ge(Li) detector. Artificial mixtures of the interfering elements in varying proportions are prepared, so as to reproduce possible real samples, where the elements may be present at several concentrations. Radiochemical separation techniques for the cited elements are studied with the use of tracers. For the separation of scadium and zinc, the technique of extraction chromatography is applied. The separation of mercury and selenium is accomplished by means of ion exchange. The technique of coprecipitation is used to separate bromine from arsenic and antimony followed by ion exchange to isolate these two elements from each other. The precision and the accuracy of the results are discussed. (Author) [pt

  10. Ring-element analysis of layered orthotropic bodies

    DEFF Research Database (Denmark)

    Jørgensen, O.

    1993-01-01

    For the analysis of arbitrarily laminated circular bodies, a displacement-based ring-element is presented. The analysis is performed in a cylindrical coordinate system. The method of analysis requires the boundary conditions as well as the external forces to be pi-periodic. The element formulation...... accounts for a desired degree of approximation of the displacement field in the direction of the circumference. This is done by a truncated Fourier expansion of the angular dependence of the displacements in terms of trigonometric functions. Thus the Fourier expansion coefficients are the unknowns...... to that of solutions obtained by traditional 3D elements. A scheme for analytical integration of the angular dependence of the stiffness matrix is given....

  11. Elemental hair analysis: A review of procedures and applications

    International Nuclear Information System (INIS)

    Pozebon, D.; Scheffler, G.L.; Dressler, V.L.

    2017-01-01

    Although exogenous contamination and unreliable reference values have limited the utility of scalp hair as a biomarker of chemical elements exposure, its use in toxicological, clinical, environmental and forensic investigations is growing and becoming more extensive. Therefore, hair elemental analysis is reviewed in the current manuscript which spans articles published in the last 10 years. It starts with a general discussion of history, morphology and possible techniques for elemental analysis, where inductively coupled plasma-mass spectrometry (ICP-MS) is clearly highlighted since this technique is leading quantitative ultra-trace elemental analysis. Emphasis over sampling, quality assurance, washing procedures and sample decomposition is given with detailed protocols compiled in tables as well as the utility of hair to identify human gender, age, diseases, healthy conditions, nutrition status and contamination sites. Isotope ratio information, chemical speciation analysis and analyte preconcentration are also considered for hair. Finally, the potential of laser ablation ICP-MS (LA-ICP-MS) to provide spatial resolution and time-track the monitoring of elements in hair strands instead of conventional bulk analysis is spotlighted as a real future trend in the field. - Highlights: • Elemental analysis of hair is critically reviewed, with focus on ICP-MS employment. • Standards protocols of hair washing and sample decomposition are compiled. • The usefulness of elemental and/or isotopic analysis of hair is demonstrated. • The potential of LA-ICP-MS for elemental time tracking in hair is highlighted.

  12. Fast XRF analysis of mineral elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Constantinescu, B.; Preoteasa, E.

    2001-01-01

    Dental composites, made of particles of glass, ceramics or quartz embedded in an organic polymer matrix, extensively replaced silver amalgam in tooth fillings and enabled new applications for restorative dentistry. Long-term alteration of dental fillings together with market pressure motivates the development of composites at a high rate, largely by progress of materials forming their mineral phase. Therefore, dental composites constantly bring at the interface with enamel and dentine new elements foreign to the organism, whose biological action has not been studied. Atomic and nuclear methods for surface multielemental analysis have been used in dental research but not for composites. X-ray fluorescence (XRF) is suited for the fast microanalytical screening of the elements and of their changes at the biomaterial's surface. The potential of radioisotope-excited XRF for the analysis of dental composites has been examined. Flat disk-shaped samples of composites have been prepared and polymerized chemically or by irradiation with intense 420-500 nm light. The measurements were performed with a spectrometric chain containing a 30 mCi source of 241 Am, a Si(Li) detector, and a multichannel analyzer. The spectra were built up for 2000-6000 sec. The characteristic X lines were integrated and normalized to source lines. The following Z ≥ 20 elements were detected in the studied composites: Ba only in Charisma (Kulzer) and Pekafill (Bayer); Zr, Ba, Yb in Tetric Ceram, and Ca, Ba, Yb together with traces of possibly Ti and Fe in Ariston (both from Vivadent); Zr, Hf in Valux Plus (3M Dental); and Sr, Ba together with some trace element, seemingly Cu, in F2000 Compomer (3M Dental) and with other trace elements like Ca, Fe in Surefil (Dentsply). Among older materials, Concise (3M Dental) contained only light (Z 3 that releases F for protection of enamel and dentine. Yb, Zr, Ba, Hf improve the radiological opacity of the materials. Some elements may accompany others as

  13. 40 CFR 798.5385 - In vivo mammalian bone marrow cytogenetics tests: Chromosomal analysis.

    Science.gov (United States)

    2010-07-01

    ... Genetic Toxicity § 798.5385 In vivo mammalian bone marrow cytogenetics tests: Chromosomal analysis. (a... chosen for the test. Slides shall be coded before microscopic analysis. (f) Data and report—(1) Treatment... cytogenetics tests: Chromosomal analysis. 798.5385 Section 798.5385 Protection of Environment ENVIRONMENTAL...

  14. Analysis of elements present in beers and brewing waters by neutron activation analysis

    International Nuclear Information System (INIS)

    Krausova, Ivana; Kucera, Jan; Dostalek, Pavel; Potesil, Vaclav

    2011-01-01

    Neutron activation analysis (NAA) was used for determination of Si, Na, K, Ca, Sc, V, Cr, Mn, Fe, Co, Zn, Rb, Cs, and La in Czech beers and brewing waters. The Si concentration in beer determined by the reaction 29 Si(n,p) 29 Al with fast neutrons confirmed that beer is an important Si source in human diet. Determination of other trace elements by NAA with the whole spectrum of reactor neutrons aimed at the feasibility of identification of Gambrinus beers brewed in various breweries. The elements Ca and V appeared to be the best candidates for this purpose. The concentrations of elements determined by NAA were also compared with the recommended daily element intake for humans. The accuracy of the method was proved by analysis of reference materials, specifically NIST SRM 2704 Buffalo River Sediment, NIST SRM 1633b Coal Fly Ash, and NIST SRM 1515 Apple Leaves. (author)

  15. Activation analysis with small mobile reactors

    International Nuclear Information System (INIS)

    Chung, C.

    1990-01-01

    A small nuclear reactor (a low-power reactor without heat removal devices) usually has thermal power output under 100 W and an average in-core thermal neutron flux below 10 9 n/cm 2 s. Conventional activation analysis is restricted to determination of specific elements with large neutron capture cross sections in sizable samples. In-vivo prompt gamma activation analysis (IVPGAA) can be used for diagnosis of elemental composition of the human body, particularly the essential elements Ca, Cl, N, and P in the whole body, and toxic Cd and Hg in contaminated organs. In this chapter, activation analysis using an external neutron beam from the Tsing Hua Mobile Educational Reactor (THMER) for in vivo activation is described. Characteristics of the mobile reactor, in-vivo medical diagnosis, and radiation safety are emphasized. 17 refs, 12 figs, 3 tabs

  16. Comparison of the bioavailability of elemental waste laden soils using ''in vivo'' and ''in vitro'' analytical methodology and refinement of exposure/dose models. 1998 annual progress report

    International Nuclear Information System (INIS)

    Buckley, B.; Gallo, M.; Georgopoulos, P.; Lioy, P.J.; Tate, R.

    1998-01-01

    'The authors hypotheses are: (1) the more closely the synthetic, in vitro, extractant mimics the extraction properties of the human digestive bio-fluids, the more accurate will be the estimate of an internal dose; (2) performance can be evaluated by in vivo studies with a rat model and quantitative examination of a mass balance, calculation and dose estimates from model simulations for the in vitro and in vivo system; and (3) the concentration of the elements Pb, Cd, Cr and selected Radionuclides present in the bioavailable fraction obtained with a synthetic extraction system will be a better indicator of contaminant ingestion from a contaminated soil because it represents the portion of the mass which can yield exposure, uptake and then the internal dose to an individual. As of April 15, 1998, they have made significant progress in the development of a unified approach to the examination of bioavailability and bioaccessibility of elemental contamination of soils for the ingestion route of exposure. This includes the initial characterization of the soil, in vitro measurements of bioaccessibility, and in vivo measurements of bioavailability. They have identified the basic chemical and microbiological characteristics of waste laden soils. These have been used to prioritize the soils for potential mobility of the trace elements present in the soil. Subsequently they have employed a mass balance technique, which for the first time tracked the movement and distribution of elements through an in vitro or in vivo experimental protocol to define the bioaccessible and the bioavailable fractions of digested soil. The basic mass balance equation for the in vitro system is: MT = MSGJ + MIJ + MR. where MT is the total mass extractable by a specific method, MSGJ, is the mass extracted by the saliva and the gastric juices, MIJ is the mass extracted by the intestinal fluid, and MR is the unextractable portion of the initial mass. The above is based upon the use of a synthetic

  17. Finite elements for analysis and design

    CERN Document Server

    Akin, J E; Davenport, J H

    1994-01-01

    The finite element method (FEM) is an analysis tool for problem-solving used throughout applied mathematics, engineering, and scientific computing. Finite Elements for Analysis and Design provides a thoroughlyrevised and up-to-date account of this important tool and its numerous applications, with added emphasis on basic theory. Numerous worked examples are included to illustrate the material.Key Features* Akin clearly explains the FEM, a numerical analysis tool for problem-solving throughout applied mathematics, engineering and scientific computing* Basic theory has bee

  18. Medical application of in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Zanzi, I.; Aloia, J.F.

    1978-01-01

    The clinical usefulness of total body neutron activation analysis (TBNAA) was clearly established at an IAEA panel meeting in Vienna in 1972. It is best demonstrated by the studies involving the measurement of total-body calcium. This measurement provides data useful for the diagnosis and management of metabolic bone disorders. It should be emphasized, however, that while most of the applications to date have involved calcium and phosphorus, the measurement of sodium, chlorine and nitrogen also appear to be useful clinically. Total-body calcium measurements utilizing TBNAA have been used in studies of osteoporosis to establish absolute and relative deficits of calcium in patients with this disease in comparison to a normal contrast population. Changes in total-body calcium (skeletal mass) have also been useful for quantitating the efficacy of various therapies in osteoporosis. Serial measurements over periods of years provide long-term balance data by direct measurement with a higher precision (+- 2%) than is possible by the use of any other technique. In the renal osteodystrophy observed in patients with renal failure, disorders of both calcium and phosphorus, as well as electrolyte disturbances, have been studied. The measure of total-body levels of these elements gives the clinician useful data upon which to design dialysis therapy. The measurement of bone changes in endocrine dysfunction has been studied, particularly in patients with thyroid and parathyroid disorders. In parathyroidectomy, the measurement of total-body calcium, post-operatively, can indicate the degree of bone resorption. Skeletal metabolism and body composition in acromegaly and Cushing's disease have also been investigated by TBNAA. Levels of cadmium in liver and kidney have also been measured in-vivo by prompt-gamma neutron activation and associated with hypertension, emphysema and cigarette smoking

  19. Medical application of in vivo neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Zanzi, I.; Aloia, J.F.

    1978-01-01

    The clinical usefulness of total body neutron activation analysis (TBNAA) was clearly established at an IAEA panel meeting in Vienna in 1972. It is best demonstrated by the studies involving the measurement of total-body calcium. This measurement provides data useful for the diagnosis and management of metabolic bone disorders. It should be emphasized, however, that while most of the applications to date have involved calcium and phosphorus, the measurement of sodium, chlorine and nitrogen also appear to be useful clinically. Total-body calcium measurements utilizing TBNAA have been used in studies of osteoporosis to establish absolute and relative deficits of calcium in patients with this disease in comparison to a normal contrast population. Changes in total-body calcium (skeletal mass) have also been useful for quantitating the efficacy of various therapies in osteoporosis. Serial measurements over periods of years provide long-term balance data by direct measurement with a higher precision (+- 2%) than is possible by the use of any other technique. In the renal osteodystrophy observed in patients with renal failure, disorders of both calcium and phosphorus, as well as electrolyte disturbances, have been studied. The measure of total-body levels of these elements gives the clinician useful data upon which to design dialysis therapy. The measurement of bone changes in endocrine dysfunction has been studied, particularly in patients with thyroid and parathyroid disorders. In parathyroidectomy, the measurement of total-body calcium, post-operatively, can indicate the degree of bone resorption. Skeletal metabolism and body composition in acromegaly and Cushing's disease have also been investigated by TBNAA. Levels of cadmium in liver and kidney have also been measured in-vivo by prompt-gamma neutron activation and associated with hypertension, emphysema and cigarette smoking.

  20. Analysis of Riboflavin Compounds in the Rabbit Cornea In Vivo.

    Science.gov (United States)

    Hammer, Arthur; Rudaz, Serge; Guinchard, Sylvie; Kling, Sabine; Richoz, Olivier; Hafezi, Farhad

    2016-09-01

    To investigate the composition and concentration of individual riboflavin compounds in the corneal stroma in vivo after soaking with various commercially available riboflavin formulations. Experiments were performed in 26 rabbit corneas in vivo: 24 corneas were soaked with riboflavin formulations for 30 minutes or with 0.9% NaCl for control (n = 2). After treatment, corneas were excised and prepared for ultra-high-pressure liquid chromatography (UHPLC) analysis. Additionally, computational chemical analysis of riboflavin compounds and keratan sulfate were performed. The amount of riboflavin and riboflavin phosphate isomers in cornea decreased by a factor of 10 to 100, when compared to the amount in riboflavin formulations. In particular, we found an inverse relationship in the ratio of riboflavin to riboflavin phosphate isomer concentration between formulations and cornea. The electronegativity and ionization potential of riboflavin and phosphate isomers are different. The inverse relationship observed might be explained by a stronger electronegativity of the phosphate isomers, leading to a stronger repulsion by corneal proteoglycans. Indicating the individual concentration of riboflavin compounds in formulations is more representative than the total riboflavin concentration. Riboflavin formulations and CXL protocols might be improved considering the differences in diffusion and ionization potentials of the different riboflavin compounds.

  1. In vivo measurements of nitrogen, hydrogen, and carbon in genetically obese and lean pigs

    International Nuclear Information System (INIS)

    Ellis, K.J.; Shypailo, R.J.; Sheng, H.-P.; Pond, W.G.

    1992-01-01

    Characteristic gamma-rays are emitted promptly by elements during exposure to neutrons. These emissions enable a radioanalytical analysis of the body's composition of protein (nitrogen), water (hydrogen), and fat (carbon). We have used this method in vivo to determine the body composition of obese and lean pigs (10 to 20 kg body wt) fed an altered cholesterol diet. (author) 10 refs.; 5 figs.; 1 tab

  2. METHODOLOGICAL ELEMENTS OF SITUATIONAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Tetyana KOVALCHUK

    2016-07-01

    Full Text Available The article deals with the investigation of theoretical and methodological principles of situational analysis. The necessity of situational analysis is proved in modern conditions. The notion “situational analysis” is determined. We have concluded that situational analysis is a continuous system study which purpose is to identify dangerous situation signs, to evaluate comprehensively such signs influenced by a system of objective and subjective factors, to search for motivated targeted actions used to eliminate adverse effects of the exposure of the system to the situation now and in the future and to develop the managerial actions needed to bring the system back to norm. It is developed a methodological approach to the situational analysis, its goal is substantiated, proved the expediency of diagnostic, evaluative and searching functions in the process of situational analysis. The basic methodological elements of the situational analysis are grounded. The substantiation of the principal methodological elements of system analysis will enable the analyst to develop adaptive methods able to take into account the peculiar features of a unique object which is a situation that has emerged in a complex system, to diagnose such situation and subject it to system and in-depth analysis, to identify risks opportunities, to make timely management decisions as required by a particular period.

  3. Single-cell and subcellular pharmacokinetic imaging allows insight into drug action in vivo.

    Science.gov (United States)

    Thurber, Greg M; Yang, Katy S; Reiner, Thomas; Kohler, Rainer H; Sorger, Peter; Mitchison, Tim; Weissleder, Ralph

    2013-01-01

    Pharmacokinetic analysis at the organ level provides insight into how drugs distribute throughout the body, but cannot explain how drugs work at the cellular level. Here we demonstrate in vivo single-cell pharmacokinetic imaging of PARP-1 inhibitors and model drug behaviour under varying conditions. We visualize intracellular kinetics of the PARP-1 inhibitor distribution in real time, showing that PARP-1 inhibitors reach their cellular target compartment, the nucleus, within minutes in vivo both in cancer and normal cells in various cancer models. We also use these data to validate predictive finite element modelling. Our theoretical and experimental data indicate that tumour cells are exposed to sufficiently high PARP-1 inhibitor concentrations in vivo and suggest that drug inefficiency is likely related to proteomic heterogeneity or insensitivity of cancer cells to DNA-repair inhibition. This suggests that single-cell pharmacokinetic imaging and derived modelling improve our understanding of drug action at single-cell resolution in vivo.

  4. A dynamic real time in vivo and static ex vivo analysis of granulomonocytic cell migration in the collagen-induced arthritis model.

    Directory of Open Access Journals (Sweden)

    Ruth Byrne

    Full Text Available Neutrophilic granulocytes and monocytes (granulomonocytic cells; GMC drive the inflammatory process at the earliest stages of rheumatoid arthritis (RA. The migratory behavior and functional properties of GMC within the synovial tissue are, however, only incompletely characterized. Here we have analyzed GMC in the murine collagen-induced arthritis (CIA model of RA using multi-photon real time in vivo microscopy together with ex vivo analysis of GMC in tissue sections.GMC were abundant as soon as clinical arthritis was apparent. GMC were motile and migrated randomly through the synovial tissue. In addition, we observed the frequent formation of cell clusters consisting of both neutrophilic granulocytes and monocytes that actively contributed to the inflammatory process of arthritis. Treatment of animals with a single dose of prednisolone reduced the mean velocity of cell migration and diminished the overall immigration of GMC.In summary, our study shows that the combined application of real time in vivo microscopy together with elaborate static post-mortem analysis of GMC enables the description of dynamic migratory characteristics of GMC together with their precise location in a complex anatomical environment. Moreover, this approach is sensitive enough to detect subtle therapeutic effects within a very short period of time.

  5. Finite element analysis of tibial fractures

    DEFF Research Database (Denmark)

    Wong, Christian Nai En; Mikkelsen, Mikkel Peter W; Hansen, Leif Berner

    2010-01-01

    Project. The data consisted of 21,219 3D elements with a cortical shell and a trabecular core. Three types of load of torsion, a direct lateral load and axial compression were applied. RESULTS: The finite element linear static analysis resulted in relevant fracture localizations and indicated relevant...

  6. Analysis of concrete beams using applied element method

    Science.gov (United States)

    Lincy Christy, D.; Madhavan Pillai, T. M.; Nagarajan, Praveen

    2018-03-01

    The Applied Element Method (AEM) is a displacement based method of structural analysis. Some of its features are similar to that of Finite Element Method (FEM). In AEM, the structure is analysed by dividing it into several elements similar to FEM. But, in AEM, elements are connected by springs instead of nodes as in the case of FEM. In this paper, background to AEM is discussed and necessary equations are derived. For illustrating the application of AEM, it has been used to analyse plain concrete beam of fixed support condition. The analysis is limited to the analysis of 2-dimensional structures. It was found that the number of springs has no much influence on the results. AEM could predict deflection and reactions with reasonable degree of accuracy.

  7. Radiolabelled cellular blood elements

    International Nuclear Information System (INIS)

    Sinzinger, H.

    1990-01-01

    This book reports on radiolabelled cellular blood elements, covering new advances made during the past several years, in particular the use of Tc-99 as a tracer for blood elements. Coverage extends to several radiolabelled monoclonal antibodies that are specific for blood components and may label blood elements in vivo

  8. Trace elements in Australian opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Fardy, J.J.

    1994-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 42 samples of black, grey and white opals taken from a number of recognised Australian field. The results were evaluated to determine if a relationship exited between trace element content and opal colour. (author) 12 refs.; 12 figs.; 3 tabs

  9. VIRTUAL EXPERIMENTAL ANALYSIS ON CLEANING ELEMENT OF SUGARCANE HARVESTER

    Institute of Scientific and Technical Information of China (English)

    Ma Fanglan; Li Shangping; He Yulin; Meng Yanmei; Chen Weixu

    2005-01-01

    The laws of influence of different factors have been analyzed in order to enhance the working efficiency and fatigue life of the cleaning element in brush shape of the sugarcane harvester.Based on the principle of orthogonal experiment design, the virtual-orthogonal-experimental analysis for the cleaning element is carried out on the finite element analysis (FEA) software-ANSYS after analyzing the nonlinear structural behavior in the working procedure. The results are analyzed with the overall balancing method, and then the optimal combination is got, which is made up of different levels of different factors. Also the optimal combination of design parameters of the cleaning element received from the virtual experimental analysis is conducted an experiment to confirm that the virtual analysis model and results are right, and the effect of factors on the function of the cleaning element is obtained by more analysis and further optimizing.

  10. In vivo measurements of nitrogen, hydrogen, carbon and potassium in genetically obese and lean pigs

    International Nuclear Information System (INIS)

    Ellis, K.J.; Shypailo, R.J.; Sheng, H.P.; Mersmann, H.J.; Pond, W.G.

    1991-01-01

    Characteristic gamma rays are emitted promptly by elements during exposure to neutrons. Gamma ray emissions enable a radioanalytical analysis of the body's composition of protein (nitrogen), water (hydrogen), fat (carbon), and muscle (natural 40 K). The authors have used this method in vivo to detect changes in the body composition of obese and lean pigs (10-20 kg body wt) in response to an altered cholesterol diet

  11. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  12. Investigation of Shear Stud Performance in Flat Plate Using Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    T.S. Viswanathan

    2014-09-01

    Full Text Available Three types of shear stud arrangement, respectively featuring an orthogonal, a radial and a critical perimeter pattern, were evaluated numerically. A numerical investigation was conducted using the finite element software ABAQUS to evaluate their ability to resist punching shear in a flat plate. The finite element analysis here is an application of the nonlinear analysis of reinforced concrete structures using three-dimensional solid finite elements. The nonlinear characteristics of concrete were achieved by employing the concrete damaged plasticity model in the finite element program. Transverse shear stress was evaluated using finite element analysis in terms of shear stress distribution for flat plate with and without shear stud reinforcement. The model predicted that shear studs placed along the critical perimeter are more effective compared to orthogonal and radial patterns.

  13. An ovine in vivo framework for tracheobronchial stent analysis.

    Science.gov (United States)

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Shea, Mary B; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2017-10-01

    Tracheobronchial stents are most commonly used to restore patency to airways stenosed by tumour growth. Currently all tracheobronchial stents are associated with complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. The present work develops a computational framework to evaluate tracheobronchial stent designs in vivo. Pressurised computed tomography is used to create a biomechanical lung model which takes into account the in vivo stress state, global lung deformation and local loading from pressure variation. Stent interaction with the airway is then evaluated for a number of loading conditions including normal breathing, coughing and ventilation. Results of the analysis indicate that three of the major complications associated with tracheobronchial stents can potentially be analysed with this framework, which can be readily applied to the human case. Airway deformation caused by lung motion is shown to have a significant effect on stent mechanical performance, including implications for stent migration, granulation formation and stent fracture.

  14. 3D morphological analysis of the mouse cerebral vasculature: Comparison of in vivo and ex vivo methods.

    Directory of Open Access Journals (Sweden)

    Joe Steinman

    Full Text Available Ex vivo 2-photon fluorescence microscopy (2PFM with optical clearing enables vascular imaging deep into tissue. However, optical clearing may also produce spherical aberrations if the objective lens is not index-matched to the clearing material, while the perfusion, clearing, and fixation procedure may alter vascular morphology. We compared in vivo and ex vivo 2PFM in mice, focusing on apparent differences in microvascular signal and morphology. Following in vivo imaging, the mice (four total were perfused with a fluorescent gel and their brains fructose-cleared. The brain regions imaged in vivo were imaged ex vivo. Vessels were segmented in both images using an automated tracing algorithm that accounts for the spatially varying PSF in the ex vivo images. This spatial variance is induced by spherical aberrations caused by imaging fructose-cleared tissue with a water-immersion objective. Alignment of the ex vivo image to the in vivo image through a non-linear warping algorithm enabled comparison of apparent vessel diameter, as well as differences in signal. Shrinkage varied as a function of diameter, with capillaries rendered smaller ex vivo by 13%, while penetrating vessels shrunk by 34%. The pial vasculature attenuated in vivo microvascular signal by 40% 300 μm below the tissue surface, but this effect was absent ex vivo. On the whole, ex vivo imaging was found to be valuable for studying deep cortical vasculature.

  15. Simultaneous multi-element analysis of some edible pulses using neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, F.H.; Metwally, E.; Abdel-Khalik, H.

    2007-01-01

    This paper comprises the application of instrumental neutron activation analysis (INAA) for multi-element determination in some edible pulse samples. These edible pulses are usually daily used in the Egyptian kitchen. These were: anise, cumin, coriander, caraway, black cumin, white kidney bean, lupine, lentil, chickpea, broad bean, peanut, almond, and fenugreek. The pulses have been analyzed as dehulled pulses, in the case of legume and oil pulses with simultaneous analysis of their respective skins. The determined elements were: Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Th and Zn. The element content in the dehulled pulses and their respective skins has been compared. Some elements were major or minor elements where others were trace elements. Standard reference materials were used to assure quality control, accuracy and precision of the technique. (author)

  16. Accuracy of gastrocnemius muscles forces in walking and running goats predicted by one-element and two-element Hill-type models.

    Science.gov (United States)

    Lee, Sabrina S M; Arnold, Allison S; Miara, Maria de Boef; Biewener, Andrew A; Wakeling, James M

    2013-09-03

    Hill-type models are commonly used to estimate muscle forces during human and animal movement-yet the accuracy of the forces estimated during walking, running, and other tasks remains largely unknown. Further, most Hill-type models assume a single contractile element, despite evidence that faster and slower motor units, which have different activation-deactivation dynamics, may be independently or collectively excited. This study evaluated a novel, two-element Hill-type model with "differential" activation of fast and slow contractile elements. Model performance was assessed using a comprehensive data set (including measures of EMG intensity, fascicle length, and tendon force) collected from the gastrocnemius muscles of goats during locomotor experiments. Muscle forces predicted by the new two-element model were compared to the forces estimated using traditional one-element models and to the forces measured in vivo using tendon buckle transducers. Overall, the two-element model resulted in the best predictions of in vivo gastrocnemius force. The coefficient of determination, r(2), was up to 26.9% higher and the root mean square error, RMSE, was up to 37.4% lower for the two-element model than for the one-element models tested. All models captured salient features of the measured muscle force during walking, trotting, and galloping (r(2)=0.26-0.51), and all exhibited some errors (RMSE=9.63-32.2% of the maximum in vivo force). These comparisons provide important insight into the accuracy of Hill-type models. The results also show that incorporation of fast and slow contractile elements within muscle models can improve estimates of time-varying, whole muscle force during locomotor tasks. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Uncertainties in elemental quantitative analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Paschoa, A.S.; Barros Leite, C.V.

    1979-01-01

    The effects of the degree of non-uniformity of the particle beam, matrix composition and matrix thickness in a quantitative elemental analysis by particle induced X-ray emission (PIXE) are discussed and a criterion to evaluate the resulting degree of uncertainty in the mass determination by this method is established. (Auth.)

  18. PIXE analysis of trace and other mineral elements in phytopharmaceutical drugs

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Harangus, Livia; Iordan, Andreea; Gugiu, M.

    2002-01-01

    Despite of ongoing progress in the biochemistry of phytopharmaceutical drugs, their mineral micro- and trace elements have not been studied in detail. These elements may have therapeutic or toxic activity which should be assessed by sensitive investigations. The latter can be done by multielemental analysis with nuclear and atomic methods. We previously found 28 elements in some Romanian plant drugs by nuclear activation analysis. The availability of this method is, however, limited by the access to a nuclear reactor. Particle-induced X-ray emission (PIXE) is an alternative method with high performances in biomedicine and requiring no sample preparation for drugs' studies. We applied PIXE in the qualitative analysis of three plant drugs - Liv52, Mentat, and Geriforte - used as invigorators, protectors and prophylactics in oxidative stress diseases. Measurements with 3 MeV protons at the 8.5 MV NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector and no additional absorber foil, evidenced unusually complex elemental compositions of drugs. Up to 31 elements with Z > 15 were found: P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Hg, and As and/or Pb, from major to trace levels. The three drugs' qualitative composition were found to be rather similar. Relative concentrations were well evaluated with X-ray yields calculated for another kind of light element thick target. Drug's toxic elements - As and/or Pb, Hg, and possibly Ga - were all at trace levels, but their accumulation might be harmful. Some essential elements like K, Ca, Cr, Fe, Cu, Zn, Br, Rb, Sr can be biologically useful. X-ray yields improvement and other ways for PIXE quantitative analysis of the phytotherapeutic drugs are outlined. (authors)

  19. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G D; Smallwood, A [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  20. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1996-01-01

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs

  1. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  2. Finite Element Analysis of Circular Plate using SolidWorks

    International Nuclear Information System (INIS)

    Kang, Yeo Jin; Jhung, Myung Jo

    2011-01-01

    Circular plates are used extensively in mechanical engineering for nuclear reactor internal components. The examples in the reactor vessel internals are upper guide structure support plate, fuel alignment plate, lower support plate etc. To verify the structural integrity of these plates, the finite element analyses are performed, which require the development of the finite element model. Sometimes it is very costly and time consuming to make the model especially for the beginners who start their engineering job for the structural analysis, necessitating a simple method to develop the finite element model for the pursuing structural analysis. Therefore in this study, the input decks are generated for the finite element analysis of a circular plate as shown in Fig. 1, which can be used for the structural analysis such as modal analysis, response spectrum analysis, stress analysis, etc using the commercial program Solid Works. The example problems are solved and the results are included for analysts to perform easily the finite element analysis of the mechanical plate components due to various loadings. The various results presented in this study would be helpful not only for the benchmark calculations and results comparisons but also as a part of the knowledge management for the future generation of young designers, scientists and computer analysts

  3. Trace and ultratrace level elemental and speciation analysis

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2012-01-01

    Accurate determination of elements present at parts per million and billion levels in various matrices is a growing requirement in different fields. In environmental sciences various trace elements need to be analyzed so as establish the dispersal models of pollutants or the adequacy of effluent treatment prior to discharge into water bodies. The issues of bioaccumulation and magnification are important in aquatic systems. In nutrition and biochemistry one has to establish the bio-availability of essential and toxic elemental species as toxic elements prevent assimilation of essential elements. Fission and fusion technologies use a variety of structural materials requiring many trace elements to be present at levels strictly below the specified levels. Ultra-pure bulk semiconductor materials are required for fabrication devices. In metallurgy and materials sciences too, various trace elements are known to influence the properties. In the emerging fields like nanotechnology, it is necessary to understand the passage and accumulation of nano-particles inside the cells, through trace analysis. Many analytical techniques exist which can provide the concentration information in the bulk materials with good accuracy. They include ICP-AES, FAAS, and ICP-MS, which are solution based techniques. Direct solid state analytical techniques are Glow Discharge Mass Spectrometry (GDMS) and XRF. Accelerator based ion-beam analysis techniques can provide information on concentration and depth profiles of different elements in layered structures. Hyphenated techniques such as HPLC/lC-ICPMS, are helpful in identifying various chemical oxidation states in which a given element might be present in a matrix, which is termed as speciation analysis. This presentation will include the existing analytical competencies and the laboratory requirements for trace and ultra trace element elemental and speciation analyses and their applications. (author)

  4. Infinite elements for soil-structure interaction analysis in multi-layered halfspaces

    International Nuclear Information System (INIS)

    Yun, Chung Bang; Kim, Jae Min; Yang, Shin Chu

    1994-01-01

    This paper presents the theoretical aspects of a computer code (KIESSI) for soil-structure interaction analysis in a multi-layered halfspace using infinite elements. The shape functions of the infinite elements are derived from approximate expressions of the analytical solutions. Three different infinite elements are developed. They are the horizontal, the vertical and the comer infinite elements (HIE, VIE and CIE). Numerical example analyses are presented for demonstrating the effectiveness of the proposed infinite elements

  5. Single cell elemental analysis using nuclear microscopy

    International Nuclear Information System (INIS)

    Ren, M.Q.; Thong, P.S.P.; Kara, U.; Watt, F.

    1999-01-01

    The use of Particle Induced X-ray Emission (PIXE), Rutherford Backscattering Spectrometry (RBS) and Scanning Transmission Ion Microscopy (STIM) to provide quantitative elemental analysis of single cells is an area which has high potential, particularly when the trace elements such as Ca, Fe, Zn and Cu can be monitored. We describe the methodology of sample preparation for two cell types, the procedures of cell imaging using STIM, and the quantitative elemental analysis of single cells using RBS and PIXE. Recent work on single cells at the Nuclear Microscopy Research Centre,National University of Singapore has centred around two research areas: (a) Apoptosis (programmed cell death), which has been recently implicated in a wide range of pathological conditions such as cancer, Parkinson's disease etc, and (b) Malaria (infection of red blood cells by the malaria parasite). Firstly we present results on the elemental analysis of human Chang liver cells (ATTCC CCL 13) where vanadium ions were used to trigger apoptosis, and demonstrate that nuclear microscopy has the capability of monitoring vanadium loading within individual cells. Secondly we present the results of elemental changes taking place in individual mouse red blood cells which have been infected with the malaria parasite and treated with the anti-malaria drug Qinghaosu (QHS)

  6. Qualitative PIXE analysis of mineral elements in some phytopharmaceutic drugs

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Harangus, Livia; Gugiu, M; Iordan, Andreea; Ciortea, C.

    2002-01-01

    A large number of phytopharmaceutic drugs are being developed, due to positive effects in various diseases and to high tolerance by the organism. While their medicinally active compounds have been identified, little attention has been paid to their mineral micro- and trace elements. The mineral elements in the drug may have therapeutic or toxic effects which should be properly assessed. Nuclear and atomic methods allow sensitive multielement detection and we previously performed nuclear activation analysis of some Romanian drugs made by plants. Despite this method's high sensitivity, its use is limited by the availability of a nuclear reactor. Particle-induced X-ray emission (PIXE) provides an alternative, and here we examined its potential for the analysis of mineral elements in three commercial phytopharmaceutical preparations, namely, Liv52, Mentat, and Geriforte. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normally oriented and connected to a multichannel analyzer and to a computer; the drug pills were fixed at 45 angle with respect to the beam. In all drugs PIXE detected mineral elements with Z > 16 down to trace levels. Major elements included K, Ca, Fe, Cu, and Zn, and minor/trace amounts of S, Cl, Ti, Cr, Mn, Ni, Ga, Br, Rb, Sr, Hg, and As/Pb were detected. Some differences were seen between the three drugs. Although at trace levels Ga, As, Hg and Pb are not toxic, one should consider that their accumulation might be harmful and caution seems recommendable on long-term cure. Most of the other elements are known to exert a positive biological role, and both in major and trace levels they may contribute to the therapeutic action. Thus PIXE analysis of mineral elements in phytopharmaceutic drugs, even qualitative, is useful for evaluating the benefits and risks in the therapy. (authors)

  7. Direct evaluation of radiation damage in human hematopoietic progenitor cells in vivo

    International Nuclear Information System (INIS)

    Kyoizumi, Seishi; McCune, J.M.; Namikawa, Reiko

    1994-01-01

    We have developed techniques by which normal functional elements of human bone marrow can be implanted into immunodeficient C.B-17 scid/scid (SCID) mice. Afterward, long-term multilineage human hematopoiesis is sustained in vivo. We evaluated the effect of irradiation on the function of human bone marrow with this in vivo model. After whole-body X irradiation of the engrafted animals, it was determined that the D 0 value of human committed progenitor cells within the human marrow was 1.00 ± 0.09 (SEM) Gy for granulocyte-macrophage colony-forming units (CFU-GM) and 0.74 ± 0.12 Gy for erythroidburst-forming units (BFU-E). The effects of irradiation on the hematopoietic elements were reduced when the radioprotective agent WR-2721 was administered prior to irradiation. After low-dose irradiation, recovery of human granulocyte colony-stimulating factor (G-CSF). This small animal model may prove amenable for the analysis of the risk of the exposure of humans to irradiation as well as for the development of new modalities for the prevention and treatment of radiation-induced hematopoietic damage. 41 refs., 5 figs., 1 tab

  8. Titanium implants with modified surfaces: Meta-analysis of in vivo osteointegration

    Energy Technology Data Exchange (ETDEWEB)

    Gasik, Michael, E-mail: michael.gasik@aalto.fi [Aalto University Foundation, School of Chemical Technology, P.O. Box 16200, FIN-00076 AALTO (Finland); Braem, Annabel [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44, B-3001 Heverlee (Belgium); Chaudhari, Amol; Duyck, Joke [Department of Prosthetic Dentistry, BIOMAT Research Cluster, KU Leuven, Kapucijnenvoer 7a, B-3000 Leuven (Belgium); Vleugels, Jozef [Department of Metallurgy and Materials Engineering, KU Leuven, Kasteelpark Arenberg 44, B-3001 Heverlee (Belgium)

    2015-04-01

    Titanium-based implants are widely used in modern clinical practice, but their “optimal” properties in terms of porosity and topology, roughness and hydrophilic parameters are being a subject of intensive discussions. Recent in vitro results have shown a possibility to optimize the surface of an implant with maximal repelling of bacteria (Staphylococcus aureus, Staphylococcus epidermidis) and improvement in human osteogenic and endothelial cell adhesion, proliferation and differentiation. In this work, these different grades titanium implants were tested in vivo using the same analytical methodology. In addition to material parameters, key histomorphometrical parameters such a regeneration area, bone adaptation area and bone-to-implant contact were determined after 2 and 4 weeks of implantation in rabbit animal model. Porous implants have more clear differences than non-porous ones, with the best optimum values obtained on hydrothermally treated electrophoretically deposited titanium. These in vivo data correlate well with the optimal prediction made by in vitro tests. - Highlights: • Various titanium specimens were studied in vivo on osteointegration vs their properties. • Non-porous implants had a better performance when coated with bioactive glass. • Porous implants have shown the best results for hydrothermally treated specimens. • Good correlation was found with the previous in vitro tests. • New analysis of the in vivo data has shown benefits to assess biomaterials performance.

  9. Titanium implants with modified surfaces: Meta-analysis of in vivo osteointegration

    International Nuclear Information System (INIS)

    Gasik, Michael; Braem, Annabel; Chaudhari, Amol; Duyck, Joke; Vleugels, Jozef

    2015-01-01

    Titanium-based implants are widely used in modern clinical practice, but their “optimal” properties in terms of porosity and topology, roughness and hydrophilic parameters are being a subject of intensive discussions. Recent in vitro results have shown a possibility to optimize the surface of an implant with maximal repelling of bacteria (Staphylococcus aureus, Staphylococcus epidermidis) and improvement in human osteogenic and endothelial cell adhesion, proliferation and differentiation. In this work, these different grades titanium implants were tested in vivo using the same analytical methodology. In addition to material parameters, key histomorphometrical parameters such a regeneration area, bone adaptation area and bone-to-implant contact were determined after 2 and 4 weeks of implantation in rabbit animal model. Porous implants have more clear differences than non-porous ones, with the best optimum values obtained on hydrothermally treated electrophoretically deposited titanium. These in vivo data correlate well with the optimal prediction made by in vitro tests. - Highlights: • Various titanium specimens were studied in vivo on osteointegration vs their properties. • Non-porous implants had a better performance when coated with bioactive glass. • Porous implants have shown the best results for hydrothermally treated specimens. • Good correlation was found with the previous in vitro tests. • New analysis of the in vivo data has shown benefits to assess biomaterials performance

  10. Elemental Study in Soybean and Products by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Vorapot, Permnamtip; Arporn Busamongkol; Sirinart, Laoharojanaphand

    2009-07-01

    Full text: Elements were analyzed in soybean and products by Instrumental Neutron Activation Analysis (INAA), Pseudo-Cyclic Instrumental Neutron Activation Analysis (PCINAA) and Epithermal Instrumental Neutron Activation Analysis (EINAA). Elements detected in sample were include Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn. The result showed that the nutritional contents changed after food processing. From experiments (n = 2), it was found that after food processing, the concentration of Cl and Na in soy bean curd increased from 0.0045 and 0.0011% to found 0.91 and 0.39 %, respectively. Other elements did not differ from soybean. Limits of detection for Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn were 0.05, 0.2, 50, 6, 10, 15, 0.05, 30, 40, 5, 5, 0.05 and 1 mg.kg - 1, respectively

  11. X-ray fluorescent elemental analysis. Ch. 16

    International Nuclear Information System (INIS)

    Baryshev, V.; Kulipanov, G.; Skrinsky, A.

    1991-01-01

    X-ray fluorescence analysis (XFA) is used worldwide to define a quantitative content of the elements as well as to visualize the distribution of elements in different regions (element mapping). Utilization of synchrotron radiation (SR) to excite X-ray fluorescence enables the XFA method to be qualitatively improved. This chapter reviews the experimental work in especially the last decade (author). 71 refs.; 24 figs.; 3 tabs

  12. Trace element analysis of common salt using neutron activation analysis

    International Nuclear Information System (INIS)

    Usman, K.

    1993-01-01

    Instrumental Fast Neutron Activation Analysis (IFNAA) technique has been used in the qualitative and quantitative determination of the impurity elements in common salt. Samples of the different types of common salt processed in Nigeria and some of those imported into the country were used. The type A711 KAMAN neutron generator and a high-purity Germanium (HpGe) gamma spectrometer available at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria has been used. The ORTEC ADCAM 100 Emulation Software (Maestro) was used in the qualitative measurement of the detected elements. The G.R.G Activation Analysis System by G. R. Gilmore, 1987, was used in the quantitative determination of the elements detected by relative method. Aluminium and arsenic were detected and measured

  13. Trace-element analysis in environmental sciences

    International Nuclear Information System (INIS)

    Valkovic, V.; Moschini, G.

    1988-01-01

    The use of charged-particle accelerators in trace-element analysis in the field of environmental sciences is described in this article. Nuclear reactions, charged-particle-induced X-ray emission as well as other nuclear and atomic processes can be used individually, or combined, in developing adequate analytical systems. In addition to concentration levels, concentration levels, concentration profiles can be measured, resulting in unique information. Some examples of experiments performed are described together with the suggestions for future measurements [pt

  14. Analysis of trace elements in human hair by PIXE

    International Nuclear Information System (INIS)

    Baptista, G.B.; Montenegro, E.C.; Paschoa, A.S.; Barros Leite, C.V. de.

    1980-10-01

    The PIXE method was applied to the analysis of trace elements in scalp hair using two methods for target preparation. In the first method eigth hair strands each with nearly cylindrical geommetry and approximately the same diameter were selected and placed on an aluminum frame. In the second method a given mass of hair was dissolved with nitric acid and a known amount of strontium was added to the solution and dripped on a membrane filter using a micropipet. The results for the concentrations of trace elements in hair obtained by the two methods are compared and several aspects of the analysis is discussed. (Author) [pt

  15. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1995-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 50 samples of orange, yellow, honey, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were evaluated to determine the relationship between trace elements content and opal colour. (author). 10 refs., 10 figs., 3 tabs

  16. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  17. Finite element analysis of tubular joints in offshore structures ...

    African Journals Online (AJOL)

    ... representing a 2-D model of the joint between the brace and the chord walls. This was subsequently followed but finite element analysis of six tubular joints. A global analysis was initially undertaken, then the submodel analysis carried in the areas of stress concentration. Journal of Civil Engineering, JKUAT (2001) Vol 6, ...

  18. In vivo neutron activation facility at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ma, R.; Yasumura, Seiichi; Dilmanian, F.A.

    1997-11-01

    Seven important body elements, C, N, Ca, P, K, Na, and Cl, can be measured with great precision and accuracy in the in vivo neutron activation facilities at Brookhaven National Laboratory. The facilities include the delayed-gamma neutron activation, the prompt-gamma neutron activation, and the inelastic neutron scattering systems. In conjunction with measurements of total body water by the tritiated-water dilution method several body compartments can be defined from the contents of these elements, also with high precision. In particular, body fat mass is derived from total body carbon together with total body calcium and nitrogen; body protein mass is derived from total body nitrogen; extracellular fluid volume is derived from total body sodium and chlorine; lean body mass and body cell mass are derived from total body potassium; and, skeletal mass is derived from total body calcium. Thus, we suggest that neutron activation analysis may be valuable for calibrating some of the instruments routinely used in clinical studies of body composition. The instruments that would benefit from absolute calibration against neutron activation analysis are bioelectric impedance analysis, infrared interactance, transmission ultrasound, and dual energy x-ray/photon absorptiometry.

  19. Electrical machine analysis using finite elements

    CERN Document Server

    Bianchi, Nicola

    2005-01-01

    OUTLINE OF ELECTROMAGNETIC FIELDSVector AnalysisElectromagnetic FieldsFundamental Equations SummaryReferencesBASIC PRINCIPLES OF FINITE ELEMENT METHODSIntroductionField Problems with Boundary ConditionsClassical Method for the Field Problem SolutionThe Classical Residual Method (Galerkin's Method)The Classical Variational Method (Rayleigh-Ritz's Method)The Finite Element MethodReferencesAPPLICATIONS OF THE FINITE ELEMENT METHOD TO TWO-DIMENSIONAL FIELDSIntroductionLinear Interpolation of the Function fApplication of the Variational MethodSimple Descriptions of Electromagnetic FieldsAppendix: I

  20. ANSYS mechanical APDL for finite element analysis

    CERN Document Server

    Thompson, Mary Kathryn

    2017-01-01

    ANSYS Mechanical APDL for Finite Element Analysis provides a hands-on introduction to engineering analysis using one of the most powerful commercial general purposes finite element programs on the market. Students will find a practical and integrated approach that combines finite element theory with best practices for developing, verifying, validating and interpreting the results of finite element models, while engineering professionals will appreciate the deep insight presented on the program's structure and behavior. Additional topics covered include an introduction to commands, input files, batch processing, and other advanced features in ANSYS. The book is written in a lecture/lab style, and each topic is supported by examples, exercises and suggestions for additional readings in the program documentation. Exercises gradually increase in difficulty and complexity, helping readers quickly gain confidence to independently use the program. This provides a solid foundation on which to build, preparing readers...

  1. Intercomparison and determination of trace elements in urban dust by neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Park, Kwang Won; Kang, Sang Hun

    2000-01-01

    Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratory's mean as target standard deviation, and a good result was obtained that the values fall between-1 and +1 except some elements. (author)

  2. Trace element determination study in human hair by neutron activation analysis

    International Nuclear Information System (INIS)

    Frazao, Selma Violato

    2008-01-01

    Human hair analysis studies have been subject of continuous interest due to the fact that they can be used as an important tool to evaluate trace element levels in the human body. These determinations have been carried out to use hair for environmental and occupational monitoring, to identify intoxication or poisoning by toxic metals, to assess nutritional status, to diagnose and to prevent diseases and in forensic sciences. Although hair analysis presents several advantages over other human tissue or fluid analyses, such as organ tissue, blood, urine and saliva, there are some controversies regarding the use of hair analysis data. These controversies arise from the fact that it is difficult to establish reliable reference values for trace elements in hair. The purpose of this study was to evaluate the factors that affect element concentrations in hair samples from a population considered healthy and residing in the Sao Paulo metropolitan area. The collected human head hair was cut in small pieces, washed, dried and analyzed by neutron activation analysis (NAA). Aliquots of hair samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor for 16 h under a thermal neutron flux of about 5x10 12 n cm -2 s -1 for As, Br, Ca, Co, Cr, Cs, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn determinations. The induced gamma activities of the standards and samples were measured using a gamma ray spectrometer coupled to an hiperpure Ge detector. For quality control of the results, IAEA- 85 Human Hair and INCT-TL-1 Tea Leaves certified reference materials (CRMs) were analyzed. Results obtained in these CRMs presented for most of elements, good agreement with the values of the certificates (relative errors less than 10%) and good precision (variation coefficients less than 13.6%). Results of replicate hair sample analysis showed good reproducibility indicating homogeneity of the prepared sample. Results obtained in the analyses of dyed and non-dyed hair

  3. Developments in Dynamic Analysis for quantitative PIXE true elemental imaging

    International Nuclear Information System (INIS)

    Ryan, C.G.

    2001-01-01

    Dynamic Analysis (DA) is a method for projecting quantitative major and trace element images from PIXE event data-streams (off-line or on-line) obtained using the Nuclear Microprobe. The method separates full elemental spectral signatures to produce images that strongly reject artifacts due to overlapping elements, detector effects (such as escape peaks and tailing) and background. The images are also quantitative, stored in ppm-charge units, enabling images to be directly interrogated for the concentrations of all elements in areas of the images. Recent advances in the method include the correction for changing X-ray yields due to varying sample compositions across the image area and the construction of statistical variance images. The resulting accuracy of major element concentrations extracted directly from these images is better than 3% relative as determined from comparisons with electron microprobe point analysis. These results are complemented by error estimates derived from the variance images together with detection limits. This paper provides an update of research on these issues, introduces new software designed to make DA more accessible, and illustrates the application of the method to selected geological problems.

  4. In-vivo analysis of ankle joint movement for patient-specific kinematic characterization.

    Science.gov (United States)

    Ferraresi, Carlo; De Benedictis, Carlo; Franco, Walter; Maffiodo, Daniela; Leardini, Alberto

    2017-09-01

    In this article, a method for the experimental in-vivo characterization of the ankle kinematics is proposed. The method is meant to improve personalization of various ankle joint treatments, such as surgical decision-making or design and application of an orthosis, possibly to increase their effectiveness. This characterization in fact would make the treatments more compatible with the specific patient's joint physiological conditions. This article describes the experimental procedure and the analytical method adopted, based on the instantaneous and mean helical axis theories. The results obtained in this experimental analysis reveal that more accurate techniques are necessary for a robust in-vivo assessment of the tibio-talar axis of rotation.

  5. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  6. PIXE analysis of caries related trace elements in tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Annegarn, H J; Jodaikin, A; Cleaton-Jones, P E; Sellschop, J P.F.; Madiba, C C.P.; Bibby, D [University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit; University of the Witwatersrand, Johannesburg (South Africa). Dental Research Unit)

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  7. Trace element analysis in rheumatoid arthritis under chrysotherapy

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.; Barrette, M.; Lamoureux, G.; Menard, H.A.

    1981-01-01

    Proton induced X-ray emission (PIXE) analysis is used to measure trace element concentrations in blood serum from patients with rheumatoid arthritis. Initially trace element contaminations in blood-collecting and storing devices are determined. Then mean values and nyctemeral cycles are measured both in normal subjects and patients with rheumatoid arthritis and other similar pathologies. Abnormal concentrations of Cu and Zn and anomalies in the nyctemeral cycle are found in the patients. In the second phase of the project, the special case of chrysotherapeutically treated (gold salt treatment) rheumatoid arthritis patients is studied for extended periods of time (up to 53 weeks). (orig.)

  8. Finite element application to global reactor analysis

    International Nuclear Information System (INIS)

    Schmidt, F.A.R.

    1981-01-01

    The Finite Element Method is described as a Coarse Mesh Method with general basis and trial functions. Various consequences concerning programming and application of Finite Element Methods in reactor physics are drawn. One of the conclusions is that the Finite Element Method is a valuable tool in solving global reactor analysis problems. However, problems which can be described by rectangular boxes still can be solved with special coarse mesh programs more efficiently. (orig.) [de

  9. Using the ion microprobe mass analyser for trace element analysis

    International Nuclear Information System (INIS)

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  10. Multispectral fingerprinting for improved in vivo cell dynamics analysis

    Directory of Open Access Journals (Sweden)

    Cooper Cameron HJ

    2010-09-01

    Full Text Available Abstract Background Tracing cell dynamics in the embryo becomes tremendously difficult when cell trajectories cross in space and time and tissue density obscure individual cell borders. Here, we used the chick neural crest (NC as a model to test multicolor cell labeling and multispectral confocal imaging strategies to overcome these roadblocks. Results We found that multicolor nuclear cell labeling and multispectral imaging led to improved resolution of in vivo NC cell identification by providing a unique spectral identity for each cell. NC cell spectral identity allowed for more accurate cell tracking and was consistent during short term time-lapse imaging sessions. Computer model simulations predicted significantly better object counting for increasing cell densities in 3-color compared to 1-color nuclear cell labeling. To better resolve cell contacts, we show that a combination of 2-color membrane and 1-color nuclear cell labeling dramatically improved the semi-automated analysis of NC cell interactions, yet preserved the ability to track cell movements. We also found channel versus lambda scanning of multicolor labeled embryos significantly reduced the time and effort of image acquisition and analysis of large 3D volume data sets. Conclusions Our results reveal that multicolor cell labeling and multispectral imaging provide a cellular fingerprint that may uniquely determine a cell's position within the embryo. Together, these methods offer a spectral toolbox to resolve in vivo cell dynamics in unprecedented detail.

  11. Finite element analysis of an inflatable torus considering air mass structural element

    Science.gov (United States)

    Gajbhiye, S. C.; Upadhyay, S. H.; Harsha, S. P.

    2014-01-01

    Inflatable structures, also known as gossamer structures, are at high boom in the current space technology due to their low mass and compact size comparing to the traditional spacecraft designing. Internal pressure becomes the major source of strength and rigidity, essentially stiffen the structure. However, inflatable space based membrane structure are at high risk to the vibration disturbance due to their low structural stiffness and material damping. Hence, the vibration modes of the structure should be known to a high degree of accuracy in order to provide better control authority. In the past, most of the studies conducted on the vibration analysis of gossamer structures used inaccurate or approximate theories in modeling the internal pressure. The toroidal shaped structure is one of the important key element in space application, helps to support the reflector in space application. This paper discusses the finite-element analysis of an inflated torus. The eigen-frequencies are obtained via three-dimensional small-strain elasticity theory, based on extremum energy principle. The two finite-element model (model-1 and model-2) have cases have been generated using a commercial finite-element package. The structure model-1 with shell element and model-2 with the combination of the mass of enclosed fluid (air) added to the shell elements have been taken for the study. The model-1 is computed with present analytical approach to understand the convergence rate and the accuracy. The convergence study is made available for the symmetric modes and anti-symmetric modes about the centroidal-axis plane, meeting the eigen-frequencies of an inflatable torus with the circular cross section. The structural model-2 is introduced with air mass element and analyzed its eigen-frequency with different aspect ratio and mode shape response using in-plane and out-plane loading condition are studied.

  12. Analysis and design of lumped element Marchand baluns

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Krozer, Viktor

    2008-01-01

    In this paper a novel design procedure for lumped element Marchand baluns is proposed. An analysis is performed on the balun structure in order to determine the conditions for ideal balun performance in terms of the lumped element values. The analysis is verified by two broadband designs centered...... around 22.75 GHz and differing only in terms of their impedance transformation ratio. EM simulation results on our proposed lumped element Marchand balun structure predicts an insertion loss of 4 dB and return loss of 40 dB at the design frequency of 22.75 GHz. The amplitude and phase imbalance...

  13. Elements of real analysis

    CERN Document Server

    Sprecher, David A

    2010-01-01

    This classic text in introductory analysis delineates and explores the intermediate steps between the basics of calculus and the ultimate stage of mathematics: abstraction and generalization.Since many abstractions and generalizations originate with the real line, the author has made it the unifying theme of the text, constructing the real number system from the point of view of a Cauchy sequence (a step which Dr. Sprecher feels is essential to learn what the real number system is).The material covered in Elements of Real Analysis should be accessible to those who have completed a course in

  14. Multi-element analysis of small biological samples

    International Nuclear Information System (INIS)

    Rokita, E.; Cafmeyer, J.; Maenhaut, W.

    1983-01-01

    A method combining PIXE and INAA was developed to determine the elemental composition of small biological samples. The method needs virtually no sample preparation and less than 1 mg is sufficient for the analysis. The method was used for determining up to 18 elements in leaves taken from Cracow Herbaceous. The factors which influence the elemental composition of leaves and the possible use of leaves as an environmental pollution indicator are discussed

  15. A CAREM type fuel element dynamic analysis

    International Nuclear Information System (INIS)

    Magoia, J.E.

    1990-01-01

    A first analysis on the dynamic behaviour of a fuel element designed for the CAREM nuclear reactor (Central Argentina de Elementos Modulares) was performed. The model used to represent this dynamic behaviour was satisfactorily evaluated. Using primary estimations for some of its numerical parameters, a first approximation to its natural vibrational modes was obtained. Results obtained from fuel elements frequently used in nuclear power plants of the PWR (Pressurized Water Reactors) type, are compared with values resulting from similar analysis. (Author) [es

  16. Trace element analysis of nail polishes

    International Nuclear Information System (INIS)

    Misra, G.; Mittal, V.K.; Sahota, H.S.

    1999-01-01

    Instrumental neutron activation analysis (INAA) technique was used to measure the concentrations of various trace elements in nail polishes of popular Indian and foreign brands. The aim of the present experiment was to see whether trace elements could distinguish nail polishes of different Indian and foreign brands from forensic point of view. It was found that cesium can act as a marker to differentiate foreign and Indian brands. (author)

  17. Hydrothermal analysis in engineering using control volume finite element method

    CERN Document Server

    Sheikholeslami, Mohsen

    2015-01-01

    Control volume finite element methods (CVFEM) bridge the gap between finite difference and finite element methods, using the advantages of both methods for simulation of multi-physics problems in complex geometries. In Hydrothermal Analysis in Engineering Using Control Volume Finite Element Method, CVFEM is covered in detail and applied to key areas of thermal engineering. Examples, exercises, and extensive references are used to show the use of the technique to model key engineering problems such as heat transfer in nanofluids (to enhance performance and compactness of energy systems),

  18. Elemental analysis techniques using proton microbeam

    International Nuclear Information System (INIS)

    Sakai, Takuro; Oikawa, Masakazu; Sato, Takahiro

    2005-01-01

    Proton microbeam is a powerful tool for two-dimensional elemental analysis. The analysis is based on Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma-ray Emission (PIGE) techniques. The paper outlines the principles and instruments, and describes the dental application has been done in JAERI Takasaki. (author)

  19. Prediction and phylogenetic analysis of mammalian short interspersed elements (SINEs).

    Science.gov (United States)

    Rogozin, I B; Mayorov, V I; Lavrentieva, M V; Milanesi, L; Adkison, L R

    2000-09-01

    The presence of repetitive elements can create serious problems for sequence analysis, especially in the case of homology searches in nucleotide sequence databases. Repetitive elements should be treated carefully by using special programs and databases. In this paper, various aspects of SINE (short interspersed repetitive element) identification, analysis and evolution are discussed.

  20. Multielement analysis of reagents used in chemical identification of transuranic elements

    International Nuclear Information System (INIS)

    Montalvan Estrada, A.; Brigido Flores, O.; Maslov, O.D.; Dmitriev, S.N.

    2006-01-01

    For more than 40 years, chemical identification of transuranic elements has been used at the Laboratory of Nuclear Reactions of the Join Institute for Nuclear Research, Dubna, Russia, as a secondary method of identification. Chlorination of transuranic elements obtained by nuclear reactions is an important step of the procedure in order to obtain volatile compounds able to pass through a thermo chromatographic process. To access the quality of the reagents TiCl 4 and SOCl 2 multielement analysis was carried out using both X-rays fluorescence and gamma activation. It was followed the simplest procedure for reagents samples pretreatment, so further interferences from other chemical products were avoided. X-rays fluorescence analysis was performed in a spectrometer with Si(Li) detector with a resolution for Fe (K?) of 190 eV. Both Cd-109 and Am-241 were used as isotopic sources of excitation. Gamma activation analysis was carried out using the compact electron accelerator MT-25, where gamma rays are produced in a stopping target. Among the parameters of the MT-25 are the following: energy range-10-25 MeV, gamma-ray flux-10 14 photon/s, power consumption-20 kw. Measurements of the induced activity were performed with the help of a HPGe detector, thin and coaxial Ge(Li) detectors. There were identified two elements in SOCl 2 -Nickel (3*10 -6 g/g) and Antimony (2*10 -7 g/g), while there were identified three elements in TiCl 4 - Zirconium (8*10 -7 g/g), Arsenic (9*10 -7 g/g) and Antimony (5*10 -7 g/g). Only five elements were detected in trace concentrations in the two analyzed reagents, that is for more than 57 elements capable of being detected using gamma activation analysis with the MT-25 only 5 had concentrations above the detection limits of the method. Not being chemical analogs of the synthesized transuranic elements (Z-104 and 106) and not being able to alpha or fission disintegrations there is not expected any interference from them in the chemical

  1. Analysis of light elements by PIGE

    International Nuclear Information System (INIS)

    Kim, Y. S.; Choi, H. W.; Kim, D. K.; Woo, H. J.; Kim, N. B.; Park, K. S.

    2000-01-01

    The PIGE (Proton Induced Gamma ray Emission) method was applied for the measurement of light elements Li - K. A test measurement has been performed for geological, biological, environmental and material samples by using a standard sample for each element. The measurement was performed for the two proton energies of 2.4 and 3.4 MeV, and 3.4MeV was found to yield better result for multielemental analysis. The result shows a fair agreement within 15% for all elements with standard values. The detection limits of Li, B, F and Na are less than 100 ppm, while those of the other elements are from a few hundred ppm to a few percents. (author)

  2. Development and analysis of an in vivo-compatible metabolic network of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Reifman Jaques

    2010-11-01

    Full Text Available Abstract Background During infection, Mycobacterium tuberculosis confronts a generally hostile and nutrient-poor in vivo host environment. Existing models and analyses of M. tuberculosis metabolic networks are able to reproduce experimentally measured cellular growth rates and identify genes required for growth in a range of different in vitro media. However, these models, under in vitro conditions, do not provide an adequate description of the metabolic processes required by the pathogen to infect and persist in a host. Results To better account for the metabolic activity of M. tuberculosis in the host environment, we developed a set of procedures to systematically modify an existing in vitro metabolic network by enhancing the agreement between calculated and in vivo-measured gene essentiality data. After our modifications, the new in vivo network contained 663 genes, 838 metabolites, and 1,049 reactions and had a significantly increased sensitivity (0.81 in predicted gene essentiality than the in vitro network (0.31. We verified the modifications generated from the purely computational analysis through a review of the literature and found, for example, that, as the analysis suggested, lipids are used as the main source for carbon metabolism and oxygen must be available for the pathogen under in vivo conditions. Moreover, we used the developed in vivo network to predict the effects of double-gene deletions on M. tuberculosis growth in the host environment, explore metabolic adaptations to life in an acidic environment, highlight the importance of different enzymes in the tricarboxylic acid-cycle under different limiting nutrient conditions, investigate the effects of inhibiting multiple reactions, and look at the importance of both aerobic and anaerobic cellular respiration during infection. Conclusions The network modifications we implemented suggest a distinctive set of metabolic conditions and requirements faced by M. tuberculosis during

  3. Toenail elemental analysis of Korean young adults by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lee, O.

    2016-01-01

    The element contents in toenail clippings of healthy Korean young adults were measured using an instrumental neutron activation analysis. The average contents of elements such as Na, K, Cl, Ca, Fe, Se, and Zn are 449, 474, 1024, 1677, 66, 0.7 and 94 mg/kg in men, whereas those contents in women respectively 332, 476, 836, 1097, 66, 0.8 and 104 mg/kg. The correlation analysis of toenail elements with chronic disease risks showed positive associations between Na and serum HDL-cholesterol, blood pressure, and negative associations between Se and Hs-CRP, between Zn and hemoglobin level. (author)

  4. Structural analysis of reactor fuel elements

    International Nuclear Information System (INIS)

    Weeks, R.W.

    1977-01-01

    An overview of fuel-element modeling is presented that traces the development of codes for the prediction of light-water-reactor and fast-breeder-reactor fuel-element performance. It is concluded that although the mathematical analysis is now far advanced, the development and incorporation of mechanistic constitutive equations has not kept pace. The resultant reliance on empirical correlations severely limits the physical insight that can be gained from code extrapolations. Current efforts include modeling of alternate fuel systems, analysis of local fuel-cladding interactions, and development of a predictive capability for off-normal behavior. Future work should help remedy the current constitutive deficiencies and should include the development of deterministic failure criteria for use in design

  5. Test Capability of Comparative NAA Method in Analysis of Long Lived Element in SRM 1648

    International Nuclear Information System (INIS)

    Sri-Wardani

    2005-01-01

    The comparative NAA method had been examine on the analysis of long-lived elements content in air particulate sample of NIST.SRM 1648 for evaluation of a capability of comparative NAA method that used at P2TRR. From the result of analysis it could be determined analysis elements contained in the sample, namely: Sc, Co, Zn, Br, Rb, Sb, Hf and Th with optimum results in bias of 10%. The optimum result of long-lived elements obtained on a good accuracy and precision. From the analysis data obtained showed that the comparative NAA method with Gamma Trac and APTEC software capable to analyze several kinds of elements in environmental samples. Therefore, this method could be implement in biological and healthy samples. (author)

  6. Determination of essential elements in herbal extracts by neutron activation analysis

    International Nuclear Information System (INIS)

    Francisconi, Lucilaine S.; Goncalves, Rodolfo D.M.R.; Silva, Paulo S.C. da

    2013-01-01

    Different types of therapies have been introduced as an alternative treatment to various types of human disorders, among them,the use of herbal teas have been highlighted due to its low cost, easiness of acquisition and administration. The aim of this study was to evaluate the concentrations of the elements As, Ba, Br, Ca, Co, Cr, Cs, Fe, Hf, K, Na, Rb, Sb, Sc, Se, Ta, Th, U, Zn and Zr by neutron activation analysis in extracts of medicinal plants whose use is regulated by ANVISA. The relevance of this analysis is justified by the need of contributing to the recommendation of these plants as secure sources of mineral elements both for therapeutic and dietary purpose. The technique showed good sensitivity in determining the appropriate concentration of all the determined elements. Elements potentially toxic were found at concentration that do not present threats to the organism and the elements that present important roles in metabolism were determined at concentrations that can assist both therapeutic and nutritional purposes. (author)

  7. Determination of essential elements in herbal extracts by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Francisconi, Lucilaine S.; Goncalves, Rodolfo D.M.R.; Silva, Paulo S.C. da, E-mail: lfrancisconi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Different types of therapies have been introduced as an alternative treatment to various types of human disorders, among them,the use of herbal teas have been highlighted due to its low cost, easiness of acquisition and administration. The aim of this study was to evaluate the concentrations of the elements As, Ba, Br, Ca, Co, Cr, Cs, Fe, Hf, K, Na, Rb, Sb, Sc, Se, Ta, Th, U, Zn and Zr by neutron activation analysis in extracts of medicinal plants whose use is regulated by ANVISA. The relevance of this analysis is justified by the need of contributing to the recommendation of these plants as secure sources of mineral elements both for therapeutic and dietary purpose. The technique showed good sensitivity in determining the appropriate concentration of all the determined elements. Elements potentially toxic were found at concentration that do not present threats to the organism and the elements that present important roles in metabolism were determined at concentrations that can assist both therapeutic and nutritional purposes. (author)

  8. Knock-in Luciferase Reporter Mice for In Vivo Monitoring of CREB Activity.

    Directory of Open Access Journals (Sweden)

    Dmitry Akhmedov

    Full Text Available The cAMP response element binding protein (CREB is induced during fasting in the liver, where it stimulates transcription of rate-limiting gluconeogenic genes to maintain metabolic homeostasis. Adenoviral and transgenic CREB reporters have been used to monitor hepatic CREB activity non-invasively using bioluminescence reporter imaging. However, adenoviral vectors and randomly inserted transgenes have several limitations. To overcome disadvantages of the currently used strategies, we created a ROSA26 knock-in CREB reporter mouse line (ROSA26-CRE-luc. cAMP-inducing ligands stimulate the reporter in primary hepatocytes and myocytes from ROSA26-CRE-luc animals. In vivo, these animals exhibit little hepatic CREB activity in the ad libitum fed state but robust induction after fasting. Strikingly, CREB was markedly stimulated in liver, but not in skeletal muscle, after overnight voluntary wheel-running exercise, uncovering differential regulation of CREB in these tissues under catabolic states. The ROSA26-CRE-luc mouse line is a useful resource to study dynamics of CREB activity longitudinally in vivo and can be used as a source of primary cells for analysis of CREB regulatory pathways ex vivo.

  9. In vivo myograph measurement of muscle contraction at optimal length

    Directory of Open Access Journals (Sweden)

    Ahmed Aminul

    2007-01-01

    Full Text Available Abstract Background Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. Methods We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. Results In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. Conclusion We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

  10. Alphavirus replicon approach to promoterless analysis of IRES elements.

    Science.gov (United States)

    Kamrud, K I; Custer, M; Dudek, J M; Owens, G; Alterson, K D; Lee, J S; Groebner, J L; Smith, J F

    2007-04-10

    Here we describe a system for promoterless analysis of putative internal ribosome entry site (IRES) elements using an alphavirus (family Togaviridae) replicon vector. The system uses the alphavirus subgenomic promoter to produce transcripts that, when modified to contain a spacer region upstream of an IRES element, allow analysis of cap-independent translation of genes of interest (GOI). If the IRES element is removed, translation of the subgenomic transcript can be reduced >95% compared to the same transcript containing a functional IRES element. Alphavirus replicons, used in this manner, offer an alternative to standard dicistronic DNA vectors or in vitro translation systems currently used to analyze putative IRES elements. In addition, protein expression levels varied depending on the spacer element located upstream of each IRES. The ability to modulate the level of expression from alphavirus vectors should extend the utility of these vectors in vaccine development.

  11. Quantitative in vivo elemental analysis using X-ray fluorescence and scattering techniques. Applications to cadmium, lead and bone mineral

    International Nuclear Information System (INIS)

    Nilsson, Ulf.

    1994-05-01

    The X-ray fluorescence technique for in vivo determination of cadmium concentration in the human body has been considerably improved so that the minimum concentration now is 10 μg/g for a skin-organ distance of 50 mm and a measurement time of 30 minutes. The technique has been used for measurements of cadmium in the kidney cortex of 60 non-occupationally exposed persons, showing twice the concentration (26±9 μg/g) in a sub-group of frequent tobacco smokers compared with a group of non-smokers (10±11 μg/g). Concentrations of lead in the skeleton of 112 persons have been measured at three bone sites (finger bone, tibia, heel bone) using in vivo XRF techniques either based on Co-57 or Cd-109 sources. There was a good correlation between lead levels at the three bone sites as well as to cumulative exposure index. However, the association between the amount of chelatable lead and measured bone lead levels was poor. The retention of lead in the skeleton of 14 retired workers, now studied for up to 18 years after retirement, shows a half-time of 16 years. 43 refs

  12. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guelovali, M.C.; Guenduez, G.

    1983-01-01

    The concentration of 20 trace elements in nine brands of Turkish cigarette tobacco and in a brand of pipe tobacco ash has been determined by instrumental neutron activation analysis. The percent transference of elements into smoke has been estimated from the amounts remaining in the ash. (author)

  13. A General Finite Element Scheme for Limit State Analysis and Optimization

    DEFF Research Database (Denmark)

    Damkilde, Lars

    1999-01-01

    Limit State analysis which is based on a perfect material behaviour is used in many different applications primarily within Structural Engineering and Geotechnics. The calculation methods have not reached the same level of automation such as Finite Element Analysis for elastic structures....... The computer based systems are more ad hoc based and are typically not well-integrated with pre- and postprocessors well-known from commercial Finite Element codes.A finite element based formulation of limit state analysis is presented which allows an easy integration with standard Finite Element codes...... for elastic analysis. In this way the user is able to perform a limit state analysis on the same model used for elastic analysis only adding data for the yield surface.The method is based on the lower-bound theorem and uses stress-based elements with a linearized yield surface. The mathematical problem...

  14. Application of finite element analysis in pre-operative planning for deformity correction of abnormal hip joints--a case series.

    Science.gov (United States)

    Rhyu, K H; Kim, Y H; Park, W M; Kim, K; Cho, T-J; Choi, I H

    2011-09-01

    In experimental and clinical research, it is difficult to directly measure responses in the human body, such as contact pressure and stress in a joint, but finite element analysis (FEA) enables the examination of in vivo responses by contact analysis. Hence, FEA is useful for pre-operative planning prior to orthopaedic surgeries, in order to gain insight into which surgical options will result in the best outcome. The present study develops a numerical simulation technique based on FEA to predict the surgical outcomes of osteotomy methods for the treatment of slipped capital femoral epiphyses. The correlation of biomechanical parameters including contact pressure and stress, for moderate and severe cases, is investigated. For severe slips, a base-of-neck osteotomy is thought to be the most reliable and effective surgical treatment, while any osteotomy may produce dramatic improvement for moderate slips. This technology of pre-operative planning using FEA can provide information regarding biomechanical parameters that might facilitate the selection of optimal osteotomy methods and corresponding surgical options.

  15. Multi elemental analysis of indigenous food spices in Southern Ethiopia using INAA technique

    International Nuclear Information System (INIS)

    Melkegna, T.H.; Chaubey, A.K.; Beyene, G.A.; Bitewlign, T.A.

    2017-01-01

    The objective of this study is a quantitative and qualitative analysis of essential and trace elements of four indigenous Ethiopian spices and herbs using instrumental neutron activation analysis technique. Results obtained for 16 elements: Major elements; Mg, Cl, and K; Minor elements; Na, Fe, and Mn, Zn, Br. While Al, V, Sm, Sc, La, Ba, Eu, Rb were found in traces. The spices, Affromumom korarima and Lippa Adonesis var. Koseret sebsebe were found to be very good sources of essential trace elements like Fe, Zn and Mn. The highest concentration of Mg was found in Ajowan whereas K and Fe were measured in Coriander seeds. The average daily dietary intake of some essential elements from the use of these spices were found to be below the recommended upper limit by WHO. (author)

  16. Failure location prediction by finite element analysis for an additive manufactured mandible implant.

    Science.gov (United States)

    Huo, Jinxing; Dérand, Per; Rännar, Lars-Erik; Hirsch, Jan-Michaél; Gamstedt, E Kristofer

    2015-09-01

    In order to reconstruct a patient with a bone defect in the mandible, a porous scaffold attached to a plate, both in a titanium alloy, was designed and manufactured using additive manufacturing. Regrettably, the implant fractured in vivo several months after surgery. The aim of this study was to investigate the failure of the implant and show a way of predicting the mechanical properties of the implant before surgery. All computed tomography data of the patient were preprocessed to remove metallic artefacts with metal deletion technique before mandible geometry reconstruction. The three-dimensional geometry of the patient's mandible was also reconstructed, and the implant was fixed to the bone model with screws in Mimics medical imaging software. A finite element model was established from the assembly of the mandible and the implant to study stresses developed during mastication. The stress distribution in the load-bearing plate was computed, and the location of main stress concentration in the plate was determined. Comparison between the fracture region and the location of the stress concentration shows that finite element analysis could serve as a tool for optimizing the design of mandible implants. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Some studies on light-element analysis with particle accelerators in South Africa

    International Nuclear Information System (INIS)

    Peisach, M.; Pillay, A.E.

    1993-01-01

    The analysis of elements in the range 1 ≤ Z ≤ is often difficult by most contemporary methods. The practical utility of various ion-beam techniques on light-element analysis is examined, and a comprehensive evaluation of the major analytical aspects on determinations of this nature, with particular reference to work done in South Africa, is provided. 40 refs., 8 figs., 3 tabs

  18. Determination of trace elements in chewing gum by neutron activation analysis

    International Nuclear Information System (INIS)

    Dietz, M.L.

    1990-01-01

    Six trace elements of nutritional or toxicological interest (Al, Ca, Cl, Mn, Na and Sr) were determined in three different brands of chewing gum by instrumental neutron activation analysis. For the particular brands of gum examined, none of the detected elements was found to be present at a level representing a substantial contribution to the total dietary intake of the element for an American adult. (author) 11 refs.; 3 tabs

  19. Molecular analysis of diverse elements mediating VanA glycopeptide resistance in enterococci

    DEFF Research Database (Denmark)

    Palepou, M.F.I.; Adebiyi, A.M.A.; Tremlett, C.H.

    1998-01-01

    Differences were examined among 24 distinct elements mediating VanA-type glycopeptide resistance in enterococci isolated from hospital patients and non-human sources in the UK. The methods used included long-PCR restriction fragment length polymorphism (L-PCR RFLP) analysis and DNA hybridization...... characterized by the presence of an IS1216V/IS3-like/orf1 complex and a point mutation in vanX, both of which were absent from the other 23 groups of VanA elements. This finding is consistent with the dissemination of a stable resistance element. We conclude that L-PCR RFLP analysis, combined with DNA...

  20. Sensitivity analysis overlaps of friction elements in cartridge seals

    Directory of Open Access Journals (Sweden)

    Žmindák Milan

    2018-01-01

    Full Text Available Cartridge seals are self-contained units consisting of a shaft sleeve, seals, and gland plate. The applications of mechanical seals are numerous. The most common example of application is in bearing production for automobile industry. This paper deals with the sensitivity analysis of overlaps friction elements in cartridge seal and their influence on the friction torque sealing and compressive force. Furthermore, it describes materials for the manufacture of sealings, approaches usually used to solution of hyperelastic materials by FEM and short introduction into the topic wheel bearings. The practical part contains one of the approach for measurement friction torque, which results were used to specifying the methodology and precision of FEM calculation realized by software ANSYS WORKBENCH. This part also contains the sensitivity analysis of overlaps friction elements.

  1. Elemental analysis of cotton by laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Schenk, Emily R.; Almirall, Jose R.

    2010-05-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to the elemental characterization of unprocessed cotton. This research is important in forensic and fraud detection applications to establish an elemental fingerprint of U.S. cotton by region, which can be used to determine the source of the cotton. To the best of our knowledge, this is the first report of a LIBS method for the elemental analysis of cotton. The experimental setup consists of a Nd:YAG laser that operates at the fundamental wavelength as the LIBS excitation source and an echelle spectrometer equipped with an intensified CCD camera. The relative concentrations of elements Al, Ba, Ca, Cr, Cu, Fe, Mg, and Sr from both nutrients and environmental contributions were determined by LIBS. Principal component analysis was used to visualize the differences between cotton samples based on the elemental composition by region in the U.S. Linear discriminant analysis of the LIBS data resulted in the correct classification of >97% of the cotton samples by U.S. region and >81% correct classification by state of origin.

  2. Qualitative PIXE analysis of mineral elements in some dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Gugiu, M.; Moldovan, Maria

    2002-01-01

    Dental composites, made by particles of glass, ceramics and quartz embedded in an organic polymer, develop at a high rate. However, commercial composites are expensive and recently the 'Restacril' biomaterials company became prepared to offer a low-cost alternative. The durability of dental fillings depends not only on biomaterial's gross chemical composition, but also on impurities. These may influence the chemical, mechanical and surface properties of the inorganic particles and modify the composites' clinical behavior. Thus elemental analysis is necessary to improve the biomaterials' quality. Nuclear and atomic methods allow sensitive multielement detection, and we previously analyzed some commercial composites by particle-induced X-ray emission (PIXE). Here we applied PIXE in the qualitative analysis of six new Romanian biomaterials, aiming to compare their nominal and detected composition and paying attention to the impurities. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normal to the beam and connected to a multichannel analyzer and to a computer. Solid samples of composites with a flat surface were fixed at 45 angle, absorber foil of Al 30 mm thick was used, and integration of beam current was done. In all composites PIXE detected mineral elements with Z > 19 down to trace levels. All major nominal elements with Z > 20 - Ca, Sr, Zr, Ba, and Yb - were detected by PIXE. In addition, many minor and trace elements absent from the nominal formulations were seen, including K, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Ag, Cd, Hf, and As/Pb. Such impurities may come from rough materials and preparative technologies. The impurities in Romanian composites are comparable to those in some commercial biomaterials but higher than in other ones. Thus PIXE analysis of mineral elements in Romanian composites, even qualitative, appears useful for quality control and improvement. (authors)

  3. Application of micro-PIXE analysis to investigate trace elements in deciduous teeth enamel

    International Nuclear Information System (INIS)

    Igari, K.; Takahashi, A.; Ando, H.

    2010-01-01

    The early life environment has widespread consequences for later health and disease. To prevent the disease in later life, the assessment of fetal environment is very important. In Japan, birthweight has fallen rapidly during recent two decades. The reduction of birthweight represents reduced fetal nutrition. Deciduous tooth enamel contains pre- and postnatal enamel and its chemical composition reflects the status of metabolism of trace elements during formation period. Deciduous tooth enamel is considered to be a suitable indicator of trace elements exposure in utero. We applied micro-PIXE analysis to investigate the trace elemental content in deciduous tooth enamel. Two deciduous canines from one healthy Japanese boy were used for this study. The enamel section including pre- and postnatal enamel was prepared for micro-PIXE analysis. Five trace elements (Na, Mg, Cl, Zn, and Sr) were detected in the scanning area of tooth. The distribution profiles of 5 elements were obtained as X-ray maps. The distribution profiles of zinc and chlorine were specific, and showed higher concentration in surface enamel. No elements showed different profiles of X-ray maps between pre- and postnatal enamel in this sample. The results of this study suggested that micro-PIXE analysis would be able to estimate the trace elements in prenatal and postnatal enamel, respectively. (author)

  4. PIXE - a new method for elemental analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1983-01-01

    With elemental analysis we mean the determination of which chemical elements are present in a sample and of their concentration. This is an old and important problem in chemistry. The earliest methods were purely chemical and many such methods are still used. However, various methods based on physical principles have gradually become more and more important. One such method is neutron activation. When the sample is bombarded with neutrons it becomes radioactive and the various radioactive isotopes produced can be identified by the radiation they emit. From the measured intensity of the radiation one can calculate how much of a certain element that is present in the sample. Another possibility is to study the light emitted when the sample is excited in various ways. A spectroscopic investigation of the light can identify the chemical elements and allows also a determination of their concentration in the sample. In the same way, if a sample can be brought to emit X-rays, this radiation is also characteristic for the elements present and can be used to determine the elemental concentration. One such X-ray method which has been developed recently is PIXE. The name is an acronym for Particle Induced X-ray Emission and indicates the principle of the method. Particles in this context means heavy, charged particles such as protons and a-particles of rather high energy. Hence, in PIXE-analysis the sample is irradiated in the beam of an accelerator and the emitted X-rays are studied. (author)

  5. Analysis of toxical element in the whitening cream cosmetic samples using neutron activation analysis (NAA)

    International Nuclear Information System (INIS)

    Th Rina M; Sunarko

    2007-01-01

    Neutron activation analysis has been done to analyze of toxical elements that is not allowed in the whitening cream cosmetic. These samples have been randomly selected from the cosmetic market. The samples were irradiated at thermal neutron flux of 10"1"33n.cm"-"2s"-"1 in the irradiation facility of rabbit system in the RSG-GAS reactor Serpong. Counting of irradiated samples have been done by a high resolution HPGe detector couple to multichannel analyzer. Data have been analyzed by GENIE 2000. The sample have been qualitatively determined up to 19 elements. These elements are: As, Br, Ce, Co, Cr, Cs, Eu, Fe, Hg, K, La, Na, Rb, Sb, Se, Sc, Rb, Th, IV, and Zn. The result of qualitative analysis showed that the toxical elements present in the samples are Hg, As, Cr and Sb with the following concentration ranges in μg/g 25.2-65.1, 1.0-6.3, 30.5-89.1 and 2.9-5.3, respectively and these element not allowed in the whitening cream cosmetic. Besides that, the others elements have been detected in the samples are Br, Fe, Zn, Sc and Co, with concentration ranges, 13.1-36.4, 65.6-159.3, 0.79-77.1, 0.5-19.5, and 6.8-31.7 μg/g, respectively, in the sample whitening cream cosmetic. (author)

  6. Determination of toxic elements in tobacco products by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, S.; Chaudhry, M.S.; Qureshi, I.H.

    1979-01-01

    The concentration of 15 elements in various brands of cigarette tobacco and cigarette wrapping paper were determined using instrumental neutron activation analysis. The paper of some of the brands contains higher concentrations of toxic elements than the tobacco. The cigarette filter and the ash were also analyzed to determine the adsorption of toxic elements on the filter and their transference in smoke. The toxic effects of some of the elements have been briefly discussed. (author)

  7. Elemental analysis of bottom ash from municipal incinerator by neutron activation analysis

    International Nuclear Information System (INIS)

    Kim, S. H.; Jang, S. H.; Moon, J. H.; Jung, Y. S.; Kim, Y. J.

    2003-01-01

    Elemental analysis of bottom ash generated from municipal solid waste incinerator was performed by neutron activation analysis. For this study, ash samples monthly collected from incinerator in D city were sieved with 5 mm mesh size, dried, pulverized by agate mortar and finally re-sieved with 200μ mesh size. Prepared samples were irradiated by neutrons using NAA No.1 irradiation hole in Korea Atomic Energy Research Institute. Activated samples were measured by gamma-ray spectrometer according to the relevant nuclear properties of target nuclides and the concentration of 33 elements were determined from the collected ash samples. Quality control was conducted by comparative analysis with two NIST standard reference materials simultaneously. Mean values and standard deviations of hazardous elements such as As, Cr, Cu, Fe, Mn, Sb and Zn among the determined elements were 3.8±6.9mg/kg, 620±0.12 %, 4.76±0.37 %, 0.26±0.10 %, 115±29 mg/kg and 0.71±0.19 %, respectively

  8. ICP-AES analysis of trace elements in serum from animals fed with irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi

    1986-01-01

    A method of trace element analysis by ICP-AES in serum from animals fed with irradiated food is described. In order to demonstrate that irradiated food is suitable for human consumption, it is necessary to perform an experiment of animal feeding with these food before use for human. Trace element analysis in animal serum could provide an actual evidence for further human consumption study. 53 serum samples of the rats fed with irradiated food were obtained. After ashed and solved, ICP-AES analysis has been used for determining 20 trace elements in specimen solution. The detection limitation is in the range of 10 -2 -10 -3 ppm for different elements. The recovery of elements is from 70.08% to 98.28%. The relative standard deviation is found to be 0.71% to 11.52%

  9. A refined element-based Lagrangian shell element for geometrically nonlinear analysis of shell structures

    Directory of Open Access Journals (Sweden)

    Woo-Young Jung

    2015-04-01

    Full Text Available For the solution of geometrically nonlinear analysis of plates and shells, the formulation of a nonlinear nine-node refined first-order shear deformable element-based Lagrangian shell element is presented. Natural co-ordinate-based higher order transverse shear strains are used in present shell element. Using the assumed natural strain method with proper interpolation functions, the present shell element generates neither membrane nor shear locking behavior even when full integration is used in the formulation. Furthermore, a refined first-order shear deformation theory for thin and thick shells, which results in parabolic through-thickness distribution of the transverse shear strains from the formulation based on the third-order shear deformation theory, is proposed. This formulation eliminates the need for shear correction factors in the first-order theory. To avoid difficulties resulting from large increments of the rotations, a scheme of attached reference system is used for the expression of rotations of shell normal. Numerical examples demonstrate that the present element behaves reasonably satisfactorily either for the linear or for geometrically nonlinear analysis of thin and thick plates and shells with large displacement but small strain. Especially, the nonlinear results of slit annular plates with various loads provided the benchmark to test the accuracy of related numerical solutions.

  10. Neutron activation analysis of trace elements in rain water

    International Nuclear Information System (INIS)

    Luten, J.B.

    1977-01-01

    In this thesis the principles and practical aspects of activation analysis which are of direct importance in the analysis of rain water, are presented together with recent literature data on other techniques. Problems due to the storage of rain water samples are discussed. A multi-element method for the determination of trace elements in rain water by instrumental neutron activation analysis is described. Gamma ray spectrometry using Ge(Li) detectors offers the possibility to determine Na, Al, Cl, V, Mn, Co, Cu, Br and I in rain water samples of 2.5 ml after a 4-min irradiation in a thermal neutron flux of 5 x 10 13 n cm -2 s -1 . In residues of rain water samples of 100 ml, irradiated during 2 days in a thermal neutron flux of >5 x 10 13 n cm -2 s -1 Cr, Fe, Co, Zn and Sb can be determined after a cooling period of approximately 21 days. The detection limits are lower than those reported in previous investigations except for Cu. The precision is about 10% or better, except for Co, Cu and I. A routine method for the determination of bromine and iodine in rain water by n.a.a. is presented. The elements are isolated by isotope exchange between the irradiated sample and a solution of Br 2 or I 2 in CCl 4 . The method is not sensitive to the chemical species in which the halogen is present. Irradiation of solutions of iodine compounds in a high thermal neutron flux gives rise to the formation of iodate. Results of a further investigation of this phenomenon are given, as well as the determination of iodate in rain water by n.a.a. Iodate is separated by anion exchange. The combination of n.a.a. and solvent extraction is used for the determination of five trace elements (V, Co, Cu, Zn and In) in 10-ml rain water samples. For V, Co and Cu this method is more sensitive and reproducible than instrumental n.a.a. The results of the analysis of eleven sequential 30-ml samples from the beginning of the shower are presented as an illustration of possible applications of the

  11. Finite element analysis of structures through unified formulation

    CERN Document Server

    Carrera, Erasmo; Petrolo, Marco; Zappino, Enrico

    2014-01-01

    The finite element method (FEM) is a computational tool widely used to design and analyse  complex structures. Currently, there are a number of different approaches to analysis using the FEM that vary according to the type of structure being analysed: beams and plates may use 1D or 2D approaches, shells and solids 2D or 3D approaches, and methods that work for one structure are typically not optimized to work for another. Finite Element Analysis of Structures Through Unified Formulation deals with the FEM used for the analysis of the mechanics of structures in the case of linear elasticity. The novelty of this book is that the finite elements (FEs) are formulated on the basis of a class of theories of structures known as the Carrera Unified Formulation (CUF). It formulates 1D, 2D and 3D FEs on the basis of the same ''fundamental nucleus'' that comes from geometrical relations and Hooke''s law, and presents both 1D and 2D refined FEs that only have displacement variables as in 3D elements. It also covers 1D...

  12. Analysis of Brick Masonry Wall using Applied Element Method

    Science.gov (United States)

    Lincy Christy, D.; Madhavan Pillai, T. M.; Nagarajan, Praveen

    2018-03-01

    The Applied Element Method (AEM) is a versatile tool for structural analysis. Analysis is done by discretising the structure as in the case of Finite Element Method (FEM). In AEM, elements are connected by a set of normal and shear springs instead of nodes. AEM is extensively used for the analysis of brittle materials. Brick masonry wall can be effectively analyzed in the frame of AEM. The composite nature of masonry wall can be easily modelled using springs. The brick springs and mortar springs are assumed to be connected in series. The brick masonry wall is analyzed and failure load is determined for different loading cases. The results were used to find the best aspect ratio of brick to strengthen brick masonry wall.

  13. Method to determine trace elements in water samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Kueppers, G.; Erdtmann, G.

    1981-05-01

    For the determination of trace elements in water by neutron activation analysis irradiation porcedures and chemical separation procedures have been developed. Irradiation in melted quarz glass ampoules in the presence of a platinum wire (for recombination of the oxyhydrogen gas produced by radiolysis) proved successfull with different variants of the irradiation methods, as long irradiation periods without pressure build-up could be achieved. Possible falsifications of the analysis results were investigated in detail (losses by absorption on vessel walls etc.). The irradiated samples can be measured directly with a gamma ray spectrometer and from the radionuclides found the trace element contents may be calculated. More sensitive determinations are possible if the radionuclides are chemically separated. Procedures for removing the matrix activities, for the separation of the radionuclides in groups of elements and for the isolation of single elements have been developed. For especially sensitive determination of some elements selective separation procedures for antimony, cadmium, selenium, mercury and uranium have been developed. The analytical procedures described have been applied to trace element determinations in river water, glacier ice and water solutions from technical processes. (orig./RB) [de

  14. A proposal for a determination method of element division on an analytical model for finite element elastic waves propagation analysis

    International Nuclear Information System (INIS)

    Ishida, Hitoshi; Meshii, Toshiyuki

    2010-01-01

    This study proposes an element size selection method named the 'Impact-Meshing (IM) method' for a finite element waves propagation analysis model, which is characterized by (1) determination of element division of the model with strain energy in the whole model, (2) static analysis (dynamic analysis in a single time step) with boundary conditions which gives a maximum change of displacement in the time increment and inertial (impact) force caused by the displacement change. In this paper, an example of application of the IM method to 3D ultrasonic wave propagation problem in an elastic solid is described. These examples showed an analysis result with a model determined by the IM method was convergence and calculation time for determination of element subdivision was reduced to about 1/6 by the IM Method which did not need determination of element subdivision by a dynamic transient analysis with 100 time steps. (author)

  15. Determination of trace elements in tea leaves by neutron activation analysis

    International Nuclear Information System (INIS)

    Kasrai, M.; Shoushtarian, M.J.; Bozorgzadeh, M.H.

    1977-01-01

    Instrumental neutron-activation analysis has been employed to determine 14 trace elements in two brands of Iranian and foreign tea. A popular local brand (Ghoncheh) and a foreign brand (Lipton tea bags) were randomly purchased. The samples were dried in an oven (100 deg C) and used without further treatment. In order to measure the concentration of elements in tea solution, weighed amounts of tea were mixed with double-distilled boiling water. After cooling the leaves were separated by centrifugation. Aliquots of clear solution were dried for analysis. Three sets of standards containing the following elements using the spec-pure materials were prepared: (a) Cl, Mn, Na, K; (b) Br, La, Au; (c) Cr, Fe, Rb, Sc, Cs, Zn, Co. In each irradiation, one set of standards, along with the sample, was neutron irradiated at a thermal flux of approximately 2x10 13 ncm -2 sec -1 in the Research Reactor of the Nuclear Research Centre. The period of irradiation ranged from 10 min to 4 hrs, depending on the radionuclides to be measured. The transference ratio of the elements into solution, when tea is leached by percolation, is also reported. It was found that some elements are totally transferred into solution and some are partially retained by the leaves. (T.G.)

  16. Multi-element analysis for environmental characterization and its future trends

    International Nuclear Information System (INIS)

    Sansoni, B.

    1987-04-01

    Before starting to characterize the environment by its elemental composition, it may be useful to ask about the objective of these efforts. This includes questions about the scope of environmental protection, the definition of the environment and the limitations of its characterization by elemental composition alone. In the second part of this lecture, examples are given of the elemental composition of well analysed samples from the atmosphere, hydrosphere, lithosphere and biosphere. The third part introduces the principle of multi-element analysis and the fourth part gives examples. Finally, future aspects of modern chemical analysis are outlined with respect to the multi-element principle. (orig.)

  17. Dynamic analysis and application of fuel elements pneumatic transportation in a pebble bed reactor

    International Nuclear Information System (INIS)

    Liu, Hongbing; Du, Dong; Han, Zandong; Zou, Yirong; Pan, Jiluan

    2015-01-01

    Almost 10,000 spherical fuel elements are transported pneumatically one by one in the pipeline outside the core of a pebble bed reactor every day. Any failure in the transportation will lead to the shutdown of the reactor, even safety accidents. In order to ensure a stable and reliable transportation, it's of great importance to analyze the motion and force condition of the fuel element. In this paper, we focus on the dynamic analysis of the pneumatic transportation of the fuel element and derive kinetic equations. Then we introduce the design of the transportation pipeline. On this basis we calculate some important data such as the velocity of the fuel element, the force between the fuel element and the pipeline and the efficiency of the pneumatic transportation. Then we analyze these results and provide some suggestions for the design of the pipeline. The experiment was carried out on an experimental platform. The velocities of the fuel elements were measured. The experimental results were consistent with and validated the theoretical analysis. The research may offer the basis for the design of the transportation pipeline and the optimization of the fuel elements transportation in a pebble bed reactor. - Highlights: • The kinetic equations of the fuel element in pneumatic transportation are derived. • The dynamic characteristics of the fuel element are analyzed. • Some important parameters are calculated based on the kinetic equations. • The experimental results were consistent with the analysis and verified the analysis. • This paper may offer an important guide to the research of a pebble bed reactor

  18. Determination of trace elements in biological material by neutron activation analysis

    International Nuclear Information System (INIS)

    Tran Van, L.; Teherani, D.K.

    1989-01-01

    Eighteen trace elements in biological materials [grass (Imperata cylindrica), mimosa plant (Mimosa pudica), rice] by neutron activation method were determined. In the comparative analysis the content of the same element was different in each material, although they were collected at the same place and the same sampling method was applied. (author) 4 refs.; 1 fig.; 1 tab

  19. 7th international conference ''Modern trends in activation analysis''

    International Nuclear Information System (INIS)

    Obrusnik, I.

    1987-01-01

    The conference was held on 23-27 June, 1986 in Copenhagen (DK) with the participation of specialists from 42 countries. 175 papers were submitted covering the wide field of applications of neutron activation analysis, from novel techniques to sample preparation, information processes and control, activation techniques, light element and rare earth element determination, ultratracer analysis, quality assurance, comparator methods, and reference materials. The poster session was mainly oriented to industrial applications of activation analysis, biological applications, in vivo use of neutron activation analysis, the applications of neutron activation analysis in environmental control, criminology, etc. (E.S.)

  20. Survey of trace elements in coals and coal-related materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Ruch, R.R.; Cahill, R.A.; Frost, J.K.; Camp, L.R.; Gluskoter, H.J.

    1977-01-01

    Utilizing primarily instrumental neutron activation analysis and other analytical methods such as neutron-activation analysis with radiochemical separation, emission spectrochemical analysis, atomic absorption spectroscopy, X-ray fluorescence analysis, ion-selective electrode analysis, and American Society for Testing of Materials procedures (ASTM), as many as 61 elements were quantitatively surveyed in 170 U.S. whole coals, 70 washed coals, and 40 bench samples. Data on areal and vertical distributions in various regions were obtained along with extensive information on the mode of occurence of various elements in the coal matrix itself. Efforts have been made to attain the maximal accuracy and precision possible for a wide variety of elements in the inhomogeneous coal matrix. (T.G.)

  1. Elements of abstract harmonic analysis

    CERN Document Server

    Bachman, George

    2013-01-01

    Elements of Abstract Harmonic Analysis provides an introduction to the fundamental concepts and basic theorems of abstract harmonic analysis. In order to give a reasonably complete and self-contained introduction to the subject, most of the proofs have been presented in great detail thereby making the development understandable to a very wide audience. Exercises have been supplied at the end of each chapter. Some of these are meant to extend the theory slightly while others should serve to test the reader's understanding of the material presented. The first chapter and part of the second give

  2. Determination of trace elements in cigarette and tobacco by neutron activation analysis

    International Nuclear Information System (INIS)

    Nouchpramool, S.

    1988-01-01

    The objective of this work is to determine the concentration of 22 trace elements in cigarette and tobacco by instrumental neutron activation analysis in which multielements can be analyzed simultaneously with high sensitivity and reliability as well as easy and rapid. It is well known that, trace toxic elements with high concentration may be harmful for health of smokers. Since they might damage the respiratory system and might cause other diseases. The finding for this report can be used as the basis of further study on toxic of trace elements to the smoker. The results of this analysis show that the bromine content in all samples is significantly high, but the concentration of the other elements are varying from one to another. Bromine concentration might come from soil and/or smoked tobacco leaves with methyl bromide as fungicide

  3. Complex finite element sensitivity method for creep analysis

    International Nuclear Information System (INIS)

    Gomez-Farias, Armando; Montoya, Arturo; Millwater, Harry

    2015-01-01

    The complex finite element method (ZFEM) has been extended to perform sensitivity analysis for mechanical and structural systems undergoing creep deformation. ZFEM uses a complex finite element formulation to provide shape, material, and loading derivatives of the system response, providing an insight into the essential factors which control the behavior of the system as a function of time. A complex variable-based quadrilateral user element (UEL) subroutine implementing the power law creep constitutive formulation was incorporated within the Abaqus commercial finite element software. The results of the complex finite element computations were verified by comparing them to the reference solution for the steady-state creep problem of a thick-walled cylinder in the power law creep range. A practical application of the ZFEM implementation to creep deformation analysis is the calculation of the skeletal point of a notched bar test from a single ZFEM run. In contrast, the standard finite element procedure requires multiple runs. The value of the skeletal point is that it identifies the location where the stress state is accurate, regardless of the certainty of the creep material properties. - Highlights: • A novel finite element sensitivity method (ZFEM) for creep was introduced. • ZFEM has the capability to calculate accurate partial derivatives. • ZFEM can be used for identification of the skeletal point of creep structures. • ZFEM can be easily implemented in a commercial software, e.g. Abaqus. • ZFEM results were shown to be in excellent agreement with analytical solutions

  4. Implementation of advanced finite element technology in structural analysis computer codes

    International Nuclear Information System (INIS)

    Kohli, T.D.; Wiley, J.W.; Koss, P.W.

    1975-01-01

    Advances in finite element technology over the last several years have been rapid and have largely outstripped the ability of general purpose programs in the public domain to assimilate them. As a result, it has become the burden of the structural analyst to incorporate these advances himself. This paper discusses the implementation and extension of specific technological advances in Bechtel structural analysis programs. In general these advances belong in two categories: (1) the finite elements themselves and (2) equation solution algorithms. Improvements in the finite elements involve increased accuracy of the elements and extension of their applicability to various specialized modelling situations. Improvements in solution algorithms have been almost exclusively aimed at expanding problem solving capacity. (Auth.)

  5. A computer program for structural analysis of fuel elements

    International Nuclear Information System (INIS)

    Hayashi, I.M.V.; Perrotta, J.A.

    1988-01-01

    It's presented the code ELCOM for the matrix analysis of tubular structures coupled by rigid spacers, typical of PWR's fuel elements. The code ELCOM makes a static structural analysis, where the displacements and internal forces are obtained for each structure at the joints with the spacers, and also, the natural frequencies and vibrational modes of an equivalent integrated structure are obtained. The ELCOM result is compared to a PWR fuel element structural analysis obtained in published paper. (author) [pt

  6. Integral finite element analysis of turntable bearing with flexible rings

    Science.gov (United States)

    Deng, Biao; Liu, Yunfei; Guo, Yuan; Tang, Shengjin; Su, Wenbin; Lei, Zhufeng; Wang, Pengcheng

    2018-03-01

    This paper suggests a method to calculate the internal load distribution and contact stress of the thrust angular contact ball turntable bearing by FEA. The influence of the stiffness of the bearing structure and the plastic deformation of contact area on the internal load distribution and contact stress of the bearing is considered. In this method, the load-deformation relationship of the rolling elements is determined by the finite element contact analysis of a single rolling element and the raceway. Based on this, the nonlinear contact between the rolling elements and the inner and outer ring raceways is same as a nonlinear compression spring and bearing integral finite element analysis model including support structure was established. The effects of structural deformation and plastic deformation on the built-in stress distribution of slewing bearing are investigated on basis of comparing the consequences of load distribution, inner and outer ring stress, contact stress and other finite element analysis results with the traditional bearing theory, which has guiding function for improving the design of slewing bearing.

  7. Determination of minor-and trace elements in magnesite samples, by activation analysis

    International Nuclear Information System (INIS)

    Sepulveda Munita, C.J.A.

    1979-01-01

    A method employing activation analysis with thermal neutron was developed for the determination of minor and trace elements in magnesite samples from the states of Ceara and Bahia (Brazil). Ten samples were analyzed. A qualitative analysis of the samples indicated the presence of Mn, Fe, Sc, Ca, Cu, Co and some of the lanthanides. The experimental part includes a non-destructive analysis of manganese and analysis with chemical separation of the other elements, individually or in groups, after sample dissolution, The dissolutions were made with concentrated HCl and the further separations were carried out in 8 N HCl medium. Iron was separated by means of an extraction of HFeCl 4 with isopropyl ether. Scandium and calcium were determined by retention of scandium with di-(2-ehylhexyl) phosphoric acid (HDEHP). The activities of 46 Sc and 47 Sc (a 47 Ca descendant) were employed for the analysis of scandium and calcium in the sample. In the effluent of the kieselguhr column copper and cobalt were determined, after retention in an anionic resin of the CuCl - 3 and CoCl - 3 complexes. Finally, in the effluent of the resin, the lanthanide group was separated by oxalate precipitation. In the gamma-ray spectrum of this precipitate the elements europium, cerium, samarium and lanthanum were determined. A detailed study of the possible interferences in the neutron activation analysis of the elements analysed was also made. The precision and accuracy of the results obtained and the sensitivity of the method are discussed. (Author) [pt

  8. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I.J.; Serfor-Armah, Y.; Nyarko, B.; Odamtten, G.T.

    1999-01-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard and certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done beating in mind microclimatic factors, specie type and nature of soil. (author)

  9. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I. J.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Odamtten, G.T.

    1999-04-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done bearing in mind microclimatic factors, specie type and nature of soil. (author)

  10. Determination of 28 elements in American cigarette tobacco by neutron-activation analysis

    International Nuclear Information System (INIS)

    Iskander, F.Y.; Bauer, T.L.; Klein, D.E.

    1986-01-01

    The concentrations of 28 toxic and other elements in cigarette tobacco of twelve brands commercially manufactured in the USA were determined using instrumental neutron-activation analysis. The elements determined were Al, As, Ba, Br, Ca, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, K, La, Mg, Mn, Na, Ni, Rb, Sb, Sc, Se, Sr, Th, Ti, V and Zn. The concentrations of the determined elements in the American cigarettes were compared with the elemental concentrations reported for Iranian, Pakistani and Japanese brands. It was concluded that the concentrations of As, Br, Ca, Eu, K and Zn in the samples under investigation are lower than those reported for the analysis of University of Kentucky reference cigarettes, whereas the concentrations of Mn and Na are higher. The contents of Al, Cl, Co, Cr, Cs, Fe, La, Sb, Sc, and Se are similar to those in the reference cigarettes. (author)

  11. Trace elements in precious and common opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1997-01-01

    Neutron activation analysis (NAA) was used to determine the concentration of trace elements in 44 precious and 52 common opals sampled from a number of recognised fields within Australia. The purpose of this study was to determine if precious and common opals of the same colour and location have the same or a different trace element profile. Similar numbers of black, white and grey samples were studied in each case. In most cases, common opals had a significantly higher concentration of certain trace elements when compared with precious opals. (author)

  12. Finite element analysis of FRP-strengthened RC beams

    Directory of Open Access Journals (Sweden)

    Teeraphot Supaviriyakit

    2004-05-01

    Full Text Available This paper presents a non-linear finite element analysis of reinforced concrete beam strengthened with externally bonded FRP plates. The finite element modeling of FRP-strengthened beams is demonstrated. Concrete and reinforcing bars are modeled together as 8-node isoparametric 2D RC element. The FRP plate is modeled as 8-node isoparametric 2D elastic element. The glue is modeled as perfect compatibility by directly connecting the nodes of FRP with those of concrete since there is no failure at the glue layer. The key to the analysis is the correct material models of concrete, steel and FRP. Cracks and steel bars are modeled as smeared over the entire element. Stress-strain properties of cracked concrete consist of tensile stress model normal to crack, compressive stress model parallel to crack and shear stress model tangential to crack. Stressstrain property of reinforcement is assumed to be elastic-hardening to account for the bond between concrete and steel bars. FRP is modeled as elastic-brittle material. From the analysis, it is found that FEM can predict the load-displacement relation, ultimate load and failure mode of the beam correctly. It can also capture the cracking process for both shear-flexural peeling and end peeling modes similar to the experiment.

  13. Elemental analysis of granite by instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF)

    International Nuclear Information System (INIS)

    El-Taher, A.

    2012-01-01

    The instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite samples collected from four locations in the Aswan area in South Egypt. The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10 11 n/cm 2 s in the TRIGA Mainz research reactor. Gamma-ray spectra from an hyper-pure germanium detector were analyzed. The present study provides the basic data of elemental concentrations of granite rocks. The following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U. The X-ray fluorescence (XRF) was used for comparison and to detect elements, which can be detected only by XRF such as F, S, Cl, Co, Cu, Mo, Ni, Pb, Se and V. The data presented here are our contribution to understanding the elemental composition of the granite rocks. Because there are no existing databases for the elemental analysis of granite, our results are a start to establishing a database for the Egyptian granite. It is hoped that the data presented here will be useful to those dealing with geochemistry, granite chemistry and related fields. - Highlights: ► Instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite. ► The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10 11 n/cm 2 s in the TRIGA Mainz research reactor. ► Following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U.

  14. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, Eric M.

    1997-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed

  15. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1996-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed

  16. Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis.

    Science.gov (United States)

    Papageorgiou, Spyridon N; Keilig, Ludger; Hasan, Istabrak; Jäger, Andreas; Bourauel, Christoph

    2016-06-01

    Biomechanical analysis of orthodontic tooth movement is complex, as many different tissues and appliance components are involved. The aim of this finite element study was to assess the relative effect of material alteration of the various components of the orthodontic appliance on the biomechanical behaviour of tooth movement. A three-dimensional finite element solid model was constructed. The model consisted of a canine, a first, and a second premolar, including the surrounding tooth-supporting structures and fixed appliances. The materials of the orthodontic appliances were alternated between: (1) composite resin or resin-modified glass ionomer cement for the adhesive, (2) steel, titanium, ceramic, or plastic for the bracket, and (3) β-titanium or steel for the wire. After vertical activation of the first premolar by 0.5mm in occlusal direction, stress and strain calculations were performed at the periodontal ligament and the orthodontic appliance. The finite element analysis indicated that strains developed at the periodontal ligament were mainly influenced by the orthodontic wire (up to +63 per cent), followed by the bracket (up to +44 per cent) and the adhesive (up to +4 per cent). As far as developed stresses at the orthodontic appliance are concerned, wire material had the greatest influence (up to +155 per cent), followed by bracket material (up to +148 per cent) and adhesive material (up to +8 per cent). The results of this in silico study need to be validated by in vivo studies before they can be extrapolated to clinical practice. According to the results of this finite element study, all components of the orthodontic fixed appliance, including wire, bracket, and adhesive, seem to influence, to some extent, the biomechanics of tooth movement. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  17. A Study on the Effect of Cohesive Laws on Finite Element Analysis of Crack Propagation Using Cohesive Elements

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyeongseok; Baek, Hyungchan; Kim, Hyungyu [Seoul Nat' l Univ. of Sci. and Tech., Seoul (Korea, Republic of)

    2014-04-15

    In this paper, the effect of cohesive laws on the finite element analysis of crack propagation using cohesive elements is investigated through three-point bending and double cantilever beam problems. The cohesive elements are implemented into ABAQUS/Standard user subroutines(UEL), and the shape of cohesive law is varied by changing parameters in polynomial functions of cohesive traction-separation relations. In particular, crack propagation behaviors are studied by comparing load-displacement curves of the analysis models which have different shapes of cohesive laws with the same values of fracture energy and cohesive strength. Furthermore, the influence of the element size on crack propagation is discussed in this study.

  18. Efficient Fatigue Analysis of Helix Elements in Umbilicals and Flexible Risers: Theory and Applications

    Directory of Open Access Journals (Sweden)

    Geir Skeie

    2012-01-01

    Full Text Available Fatigue analysis of structural components such as helix tensile armors and steel tubes is a critical design issue for dynamic umbilicals and flexible pipes. The basis for assessment of fatigue damage of such elements is the long-term stress cycle distribution at critical locations on the helix elements caused by long-term environmental loading on the system. The long-term stress cycle distribution will hence require global dynamic time domain analysis followed by a detailed cross-sectional analysis in a large number of irregular sea states. An overall computational consistent and efficient fatigue analysis scheme is outlined with due regard of the cross-sectional analysis technique required for fatigue stress calculation with particular attention to the helix elements. The global cross-section is exposed to pure bending, tensile, torsion, and pressure loading. The state of the different cross-section elements is based on the global response. Special emphasis is placed on assessment of friction stresses caused by the stick-slip behavior of helix elements in bending that are of special importance for fatigue life assessments. The described cross-sectional analysis techniques are based on an extensive literature survey and are hence considered to represent industry consensus. The performance of the described calculation scheme is illustrated by case studies.

  19. Nuclear-based techniques for the in vivo study of human body composition

    International Nuclear Information System (INIS)

    1986-03-01

    This report comprises working papers presented at an Advisory Group Meeting organized by the International Atomic Energy Agency. Fourteen contributions from seven countries describe measurement systems, and their applications, for the in vivo study of human body composition, mainly with respect to the elements calcium, nitrogen, sodium, chlorine, phosphorus, cadmium and lead. The techniques used include neutron activation analysis, X-ray fluorescence analysis, computerized axial tomography, nuclear resonance scattering and photon absorptiometry. Also included is a collection of ''system descriptions'' containing information on equipment developed for such measurements at seventeen centres in eight countries (institute address and name of persons to contact for more information, overall system performance, irradiation and country device, estimated cost)

  20. Finite element analysis of plastic recycling machine designed for ...

    African Journals Online (AJOL)

    ... design was evaluated using finite element analysis (FEA) tool in Solid Works Computer ... Also, a minimum factor of safety value of 5.3 was obtained for shredder shaft ... Machine; Design; Recycling; Sustainability; Finite Element; Simulation ...

  1. Assessment of bone formation capacity using in vivo transplantation assays: procedure and tissue analysis

    DEFF Research Database (Denmark)

    Abdallah, Basem; Ditzel, Nicholas; Kassem, Moustapha

    2008-01-01

    In vivo assessment of bone formation (osteogenesis) potential by isolated cells is an important method for analysis of cells and factors control ling bone formation. Currently, cell implantation mixed with hydroxyapa-tite/tricalcium phosphate in an open system (subcutaneous implantation) in immun...

  2. Improved PIXE analysis of micro- and trace elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Ciortea, C.; Fluerasu, D.; Enescu, S. E.; Preoteasa, E.

    2001-01-01

    Due to the interactions occurring at the solid-solid and solid-liquid interfaces of a tooth's filling, the mineral elements of the restorative composite may induce a complex response of the organism. To study such problems, sensitive surface trace element analysis is required. Particle-induced X-ray emission (PIXE) has a detection limit one order of magnitude lower than XRF and has been used for hard dental tissues, but not yet for dental composites. We evaluated the potential of PIXE in a study of ten types of composites used in restorative dentistry, some of them with two color shades each. The samples were prepared as described for XRF. The measurements were performed with 3 MeV protons from a van de Graaff tandem linear accelerator, using a hyper pure Ge detector and collecting the spectra for 1.5-4 hours. The spectra were processed with the program Leone. The proton route in the sample calculated with the Trim program (∼ 50-100 μm) exceeded the size of mineral particles (0.02-30 μm), thus granularity did not affect the analysis. The PIXE analysis detected Z ≥ 19 elements in all composites, and Z≥14 elements in only one low Z material. PIXE detected generally the same dominant elements, but many more trace elements than XRF. Thus both Charisma (Kulzer) and Pekafill (Bayer) contained Ba as the major element, but trace elements were Ni, Zn, In, in the first, and Fe, Cu, Zn, Sr, Ag in the second. In other glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr, In, and possibly Ti in Tetric Ceram and in Ariston (both from Vivadent); Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental); Sr, Ba (major), K, Fe, Mn (minor), and traces of Ni, Zn, In, in F2000 Compomer (3M Dental); Ba (major) and traces of Fe, Ni, Sr in Surefil (Dentsply). In quartz-based materials we detected: Si, Ca, Ti, Fe and traces of K, Cl, Cr, Ni, Cu, Zn in Evicrol (Spofa); low and trace levels of Ca, Ti, Cr, Mn, Fe, Cu in

  3. In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating

    Directory of Open Access Journals (Sweden)

    Nicolas A. Alba

    2015-10-01

    Full Text Available Neural electrodes hold tremendous potential for improving understanding of brain function and restoring lost neurological functions. Multi-walled carbon nanotube (MWCNT and dexamethasone (Dex-doped poly(3,4-ethylenedioxythiophene (PEDOT coatings have shown promise to improve chronic neural electrode performance. Here, we employ electrochemical techniques to characterize the coating in vivo. Coated and uncoated electrode arrays were implanted into rat visual cortex and subjected to daily cyclic voltammetry (CV and electrochemical impedance spectroscopy (EIS for 11 days. Coated electrodes experienced a significant decrease in 1 kHz impedance within the first two days of implantation followed by an increase between days 4 and 7. Equivalent circuit analysis showed that the impedance increase is the result of surface capacitance reduction, likely due to protein and cellular processes encapsulating the porous coating. Coating’s charge storage capacity remained consistently higher than uncoated electrodes, demonstrating its in vivo electrochemical stability. To decouple the PEDOT/MWCNT material property changes from the tissue response, in vitro characterization was conducted by soaking the coated electrodes in PBS for 11 days. Some coated electrodes exhibited steady impedance while others exhibiting large increases associated with large decreases in charge storage capacity suggesting delamination in PBS. This was not observed in vivo, as scanning electron microscopy of explants verified the integrity of the coating with no sign of delamination or cracking. Despite the impedance increase, coated electrodes successfully recorded neural activity throughout the implantation period.

  4. A study on the nonlinear finite element analysis of reinforced concrete structures: shell finite element formulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Jin; Seo, Jeong Moon

    2000-08-01

    The main goal of this research is to establish a methodology of finite element analysis of containment building predicting not only global behaviour but also local failure mode. In this report, we summerize some existing numerical analysis techniques to be improved for containment building. In other words, a complete description of the standard degenerated shell finite element formulation is provided for nonlinear stress analysis of nuclear containment structure. A shell finite element is derived using the degenerated solid concept which does not rely on a specific shell theory. Reissner-Mindlin assumptions are adopted to consider the transverse shear deformation effect. In order to minimize the sensitivity of the constitutive equation to structural types, microscopic material model is adopted. The four solution algorithms based on the standard Newton-Raphson method are discussed. Finally, two numerical examples are carried out to test the performance of the adopted shell medel.

  5. A study on the nonlinear finite element analysis of reinforced concrete structures: shell finite element formulation

    International Nuclear Information System (INIS)

    Lee, Sang Jin; Seo, Jeong Moon

    2000-08-01

    The main goal of this research is to establish a methodology of finite element analysis of containment building predicting not only global behaviour but also local failure mode. In this report, we summerize some existing numerical analysis techniques to be improved for containment building. In other words, a complete description of the standard degenerated shell finite element formulation is provided for nonlinear stress analysis of nuclear containment structure. A shell finite element is derived using the degenerated solid concept which does not rely on a specific shell theory. Reissner-Mindlin assumptions are adopted to consider the transverse shear deformation effect. In order to minimize the sensitivity of the constitutive equation to structural types, microscopic material model is adopted. The four solution algorithms based on the standard Newton-Raphson method are discussed. Finally, two numerical examples are carried out to test the performance of the adopted shell medel

  6. Completely non-destructive elemental analysis of bulky samples by PGA

    International Nuclear Information System (INIS)

    Oura, Y.; Nakahara, H.; Sueki, K.; Sato, W.; Tomizawa, T.

    1998-01-01

    A new non-destructive method is proposed for the elemental analysis of bulk samples. It is essentially a combination of PGA and NAA by a single neutron irradiation, and allows determinations of elemental contents of both major and minor constituents relative to that of some reference element. Major elements and some trace elements such as B, Sm, and Gd are mostly determined by the measurement of prompt gamma rays emitted when a bulky sample in its original form, namely, without any reduction of the sample size, is placed in the beam of neutrons guided from a nuclear reactor. Minor elements are then determined by the off-line measurements of gamma rays emitted from the radioactive nuclides produced within the sample by neutron capture reactions. As the radioactivity remaining in the sample becomes negligibly small after a few weeks cooling, the proposed method will be most usefully applied for the elemental analysis of bulky precious samples such as archaeological samples, and arts and crafts. In this presentation, applicability of the method will be demonstrated for porcelain and bronze samples. (author)

  7. In Vivo Characterization of a Vertebrate Ultra-conserved Enhancer

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Francis; Nobrega, Marcelo A.; Plajzer-Frick, Ingrid; Holt, Amy; Afzal, Veena; Rubin, Edward M.; Pennacchio, Len

    2004-10-01

    Genomic sequence comparisons between human, mouse and pufferfish (Takifugu rubripes (Fugu))have revealed a set of extremely conserved noncoding sequences. While this high degree of sequence conservation suggests severe evolutionary constraint and predicts a lack of tolerance to change in order to retain in vivo functionality, such elements have been minimally explored experimentally. In this study, we describe the in-depth characterization of an ancient conserved enhancer, Dc2 located near the dachshund gene, which displays a human-Fugu identity of 84 percent over 424 basepairs (bp). In addition to this large overall conservation, we find that Dc2 is characterized by the presence of a large block of sequence (144 bp) that is completely identical between human, mouse, chicken, zebrafish and Fugu. Through the testing of reporter vector constructs in transgenic mice, we observed that the 424 bp Dc2 conserved element is necessary and sufficient for brain tissue enhancer activity. In vivo analyses also revealed that the 144 bp 100 percent conserved sequence is necessary, but not sufficient, to replicate Dc2 enhancer function. However, the introduction of two separate 16 bp insertions into the highly conserved enhancer core did not cause any detectable modification of its in vivo activity. Our observations indicate that the 144 bp 100 percent conserved element is tolerant of change at least at the resolution of this transgenic mouse assay and suggest that purifying selection on Dc2 sequence might not be as strong as we predicted or that some unknown property also constrains this highly conserved enhancer sequence.

  8. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    Energy Technology Data Exchange (ETDEWEB)

    Dahing, Lahasen Normanshah [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia); Yahya, Redzuan [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Yahya, Roslan; Hassan, Hearie [Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia)

    2014-09-03

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  9. Nonlinear Finite Element Analysis of Shells with Large Aspect Ratio

    Science.gov (United States)

    Chang, T. Y.; Sawamiphakdi, K.

    1984-01-01

    A higher order degenerated shell element with nine nodes was selected for large deformation and post-buckling analysis of thick or thin shells. Elastic-plastic material properties are also included. The post-buckling analysis algorithm is given. Using a square plate, it was demonstrated that the none-node element does not have shear locking effect even if its aspect ratio was increased to the order 10 to the 8th power. Two sample problems are given to illustrate the analysis capability of the shell element.

  10. Finite element analysis of thermal stress distribution in different ...

    African Journals Online (AJOL)

    Nigerian Journal of Clinical Practice • Jan-Feb 2016 • Vol 19 • Issue 1. Abstract ... Key words: Amalgam, finite element method, glass ionomer cement, resin composite, thermal stress ... applications for force analysis and assessment of different.

  11. Orthodontic treatment: Introducing finite element analysis

    NARCIS (Netherlands)

    Driel, W.D. van; Leeuwen, E.J. van

    1998-01-01

    The aim of orthodontic treatment is the displacement of teeth by means ofspecial appliances, like braces and brackets. Through these appliances the orthodontist can apply a set of forces to the teeth which wilt result in its displacement through the jawbone. Finite Element analysis of this process

  12. Noninvasive Strategy Based on Real-Time in Vivo Cataluminescence Monitoring for Clinical Breath Analysis.

    Science.gov (United States)

    Zhang, Runkun; Huang, Wanting; Li, Gongke; Hu, Yufei

    2017-03-21

    The development of noninvasive methods for real-time in vivo analysis is of great significant, which provides powerful tools for medical research and clinical diagnosis. In the present work, we described a new strategy based on cataluminescence (CTL) for real-time in vivo clinical breath analysis. To illustrate such strategy, a homemade real-time CTL monitoring system characterized by coupling an online sampling device with a CTL sensor for sevoflurane (SVF) was designed, and a real-time in vivo method for the monitoring of SVF in exhaled breath was proposed. The accuracy of the method was evaluated by analyzing the real exhaled breath samples, and the results were compared with those obtained by GC/MS. The measured data obtained by the two methods were in good agreement. Subsequently, the method was applied to real-time monitoring of SVF in exhaled breath from rat models of the control group to investigate elimination pharmacokinetics. In order to further probe the potential of the method for clinical application, the elimination pharmacokinetics of SVF from rat models of control group, liver fibrosis group alcohol liver group, and nonalcoholic fatty liver group were monitored by the method. The raw data of pharmacokinetics of different groups were normalized and subsequently subjected to linear discriminant analysis (LDA). These data were transformed to canonical scores which were visualized as well-clustered with the classification accuracy of 100%, and the overall accuracy of leave-one-out cross-validation procedure is 88%, thereby indicating the utility of the potential of the method for liver disease diagnosis. Our strategy undoubtedly opens up a new door for real-time clinical analysis in a pain-free and noninvasive way and also guides a promising development direction for CTL.

  13. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1997-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed. copyright 1997 American Institute of Physics

  14. Finite element analysis of degraded concrete structures - Workshop proceedings

    International Nuclear Information System (INIS)

    1999-09-01

    This workshop is related to the finite element analysis of degraded concrete structures. It is composed of three sessions. The first session (which title is: the use of finite element analysis in safety assessments) comprises six papers which titles are: Historical Development of Concrete Finite Element Modeling for Safety Evaluation of Accident-Challenged and Aging Concrete Structures; Experience with Finite Element Methods for Safety Assessments in Switzerland; Stress State Analysis of the Ignalina NPP Confinement System; Prestressed Containment: Behaviour when Concrete Cracking is Modelled; Application of FEA for Design and Support of NPP Containment in Russia; Verification Problems of Nuclear Installations Safety Software of Strength Analysis (NISS SA). The second session (title: concrete containment structures under accident loads) comprises seven papers which titles are: Two Application Examples of Concrete Containment Structures under Accident Load Conditions Using Finite Element Analysis; What Kind of Prediction for Leak rates for Nuclear Power Plant Containments in Accidental Conditions; Influence of Different Hypotheses Used in Numerical Models for Concrete At Elevated Temperatures on the Predicted Behaviour of NPP Core Catchers Under Severe Accident Conditions; Observations on the Constitutive Modeling of Concrete Under Multi-Axial States at Elevated Temperatures; Analyses of a Reinforced Concrete Containment with Liner Corrosion Damage; Program of Containment Concrete Control During Operation for the Temelin Nuclear Power Plant; Static Limit Load of a Deteriorated Hyperbolic Cooling Tower. The third session (concrete structures under extreme environmental load) comprised five papers which titles are: Shear Transfer Mechanism of RC Plates After Cracking; Seismic Back Calculation of an Auxiliary Building of the Nuclear Power Plant Muehleberg, Switzerland; Seismic Behaviour of Slightly Reinforced Shear Wall Structures; FE Analysis of Degraded Concrete

  15. Capture analysis of element content of a substance with other neutron methods

    International Nuclear Information System (INIS)

    Kurbanov, B.I.

    2004-01-01

    Full text: Neutron analysis method of determining element composition have found wide range of applications in industry thanks to different types of interaction of neutron with substances /1/. With the aim of widening the range of problems to be solved, on the basis of the device /2/ for determining the element content of substance, possibilities of combining the method based on the use of neutron capture gamma-ray spectrometry with other neutron methods, in particular neutron activation analysis and neutron absorption analysis were studied. In this radionuclide source ( 252 Cf) with the yield of 1,5 x 10 7 neutron/sec is used. By means of using neutron capture gamma radiation spectrometry the possibilities of determining some elements (H, B, N, S etc. ), which are not determined by very widely used method, activation analysis. These elements can be determined by both the semiconductor and scintillation detectors with parameters fitting the manufacturing requirements. And for a number of elements ( B, Cl, Cd, Sm, Gd) very high limits of determination ( up to 10- 5 %) are possible using semiconductor Ge (Li) -detectors with high resolution. Possibility of determination of some 'well' activated elements ( K, Al, Fe, Mn, Ti, Sc etc.) in samples of ore and products of their processing using the neutron-activation analysis. For 1 hour of irradiation on the experimental device quite accurate analytical peak, of these elements are obtained, allowing to determine them qualitatively. However, with decreasing neutron yield of radionuclide source it becomes more difficult to achieve the necessary parameters both in neutron capture and activation analysis. Experimental works on determination of some elements with large cross-sections of capture ( B, Cd, Sm ) by absorption of neutrons in the investigated substance, i.e. using the neutron absorption analysis method with absence of other large capture cross section elements in the samples being studied

  16. Comparison of Elemental Composition in Korean Irradiated Foods using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Lee, Kye Hong; Kim, Young Jin; Choi, Jong Il; Lee, Joo Eun

    2010-01-01

    The information and role of trace mineral elements from an intake of created and processed foodstuff are important as a indicator of human health and nutritional parameter, as well as a quality control of food and diet. Particularly, special food created for consumption by astronauts in outer space may differ with common food on the earth in order to compensate a decrease of taste and nutrition by strong cosmic rays, a state of nongravitation, low pressure, and enclosed space environment. In April 2008, Korea's first astronaut became a crew member of the international space station and she was brought special space versions of Korea's national dishes such as Kimchi, boiled rice, hot red paste, green tea, ramyun, and so on. Accurate quantitative analysis of trace elements in various kinds of biological samples is also important for data quality. Neutron activation analysis is a sensitive, non-destructive, multi-elemental analytical method, and is proper for tracing elements in a biological sample in order to avoid loss and contamination by chemical pretreatment. This study analyses the distribution of concentrations for both essential and toxic elements in six kinds of Korean space foods developed by KAERI. The quantitative analytical results from instrumental neutron activation analysis are presented

  17. Measurements of fluorine in contemporary urban Canadians: a comparison of the levels found in human bone using in vivo and ex vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Mostafaei, F; McNeill, F E; Chettle, D R; Prestwich, W V; Wainman, B C; Pidruczny, A E

    2015-01-01

    Non-invasive in vivo neutron activation analysis (NAA) was used to measure the fluorine concentration in 35 people in Hamilton, Ontario, Canada. Measurement and precision data of this second generation NAA system were determined in 2013, and the results were compared with the performance of a first generation system used in a pilot study of 33 participants from the Hamilton area in 2008. Improvements in precision in line with those predicted by phantom studies were observed, but the use of fewer technicians during measurement seemed adversely to affect performance. We compared the levels of fluorine observed in people between the two studies and found them to be comparable. The average fluorine concentration in bone was found to be 3  ±  0.3 mg and 3.5  ±  0.4 mg F/g Ca for 2013 and 2008 measurements respectively. Ten people were measured in both studies; the observed average change in bone fluorine in this subgroup was consistent with that predicted by the observation of the relationship between bone fluorine and age in the wider group. In addition, we observed differences in the relationship between bone fluorine level and age between men and women, which may be attributable either to sex or gender differences. The rate of increase in fluorine content for men was found to be 0.096  ±  0.022 mg F/g Ca per year while the rate of increase for women was found to be slightly less than half that of men, 0.041  ±  0.017 mg F/g Ca per year. A discontinuity in the rate of increase in fluorine content with age was observed in women at around age 50. Bone fluorine content was significantly lower (p<0.01) in women age 50 to 59 than in women age 40 to 49, which we suggest may be attributable to bone metabolism changes associated with menopause. We also observed increased fluorine levels in tea drinkers as compared to non-tea drinkers, suggesting tea may be a significant source of exposure in Canada. The rate of increase in fluorine content

  18. Multi-element analysis of emeralds and associated rocks by k0 neutron activation analysis

    International Nuclear Information System (INIS)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B.

    2000-01-01

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k 0 method (k 0 INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method

  19. In vivo analysis at the Service Hospitalier Frederic Joliot (1965-1981)

    International Nuclear Information System (INIS)

    Maziere, B.

    1986-01-01

    In the first chapter, historical development of In-vivo Neutron Activation Analysis (I.V.N.A.A.) at the Service Hospitalier Frederic Joliot is presented. Then after having reviewed the preliminary animal experiments, the author explains the choice of the irradiation facilities used for human partial I.V.N.A.A. The clinical applications of this technique in the field of thyroid and bone metabolisms are described. The clinical results obtained in patients suffering from various demineralizing bone diseases (osteoporosis, renal osteodystrophy) are given in detail. (author)

  20. Determination of elements in cisadane river sediments by neutron activation analysis

    International Nuclear Information System (INIS)

    Kamarz, H.

    1997-01-01

    Determination of elements in Cisadane river sediments by neutron activation analysis has been conducted. Samples of sediments were obtained from some location along Cisadane river, i.e. Leuranji, Karanggan, Cibigo, Cisauk, Warung Mangga Pintu Air and Estuary Teluk Naga. the elements analysed were Al, Mn, Mg, V, K, Na, Fe, Cr, Co, U and Zn, and the results were compared to the SRM of sediment sample from IAEA. Generally, the results showed that the mean concentration of elements were found in Cibogo, Cisauk, Pintu Air and Muara Teluk Naga which were higher than others. Concentration factor of elements in sediments were in between of 0,02 - 3,45, this factor indicated that Cisadane river sediments have not been contaminated. CRM sediments 2704 from IAEA used as NAA Quality Control (author)

  1. Optimal parameters to avoid thermal necrosis during bone drilling: A finite element analysis.

    Science.gov (United States)

    Mediouni, Mohamed; Schlatterer, Daniel R; Khoury, Amal; Von Bergen, Tobias; Shetty, Sunil H; Arora, Manit; Dhond, Amit; Vaughan, Neil; Volosnikov, Alexander

    2017-11-01

    The drilling bone may potentially cause excessive frictional heat, which can lead to local bone necrosis. This heat generation and local necrosis has been suggested to contribute to the resorption of bone around the placed screws, ending in loss of screw purchase in the bone and inadvertent loosening and/or the bone-implant construct. In vivo studies on this subject have inherent obstacles not the least of which is controlling the variables and real time bone temperature data acquisition. Theoretical models can be generated using computer software and the inclusion of known constants for the mechanical properties of metal and bone. These known Data points for the variables (drill bit and bone) enables finite element analysis of various bone drilling scenarios. An elastic-plastic three-dimensional (3D) acetabular bone mode was developed and finite element model analysis (FEA) was applied to various simulated drilling procedures. The FEA results clearly indicate that the depth of drilling and the drill speed both have a significant effect on the temperature during drilling procedures. The reduction of the feeding speed leads to a reduction in bone temperature. Our data suggests that reducing the feeding speed regardless of RPMs and pressure applied could be a simple useful and effective way to reduce drilling temperatures. This study is the first step in helping any surgeon who drills bone and places screws to better understand the ideal pressure to apply and drill speed to employ and advance rate to avoid osteonecrosis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2386-2391, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Evaluation of the antidiabetic property of aqueous leaves extract of Zanthoxylum armatum DC. using in vivo and in vitro approaches

    Directory of Open Access Journals (Sweden)

    Carey Vana Rynjah

    2018-01-01

    Full Text Available The present study was designed to evaluate the antidiabetic potential of the aqueous leaves extract of Zanthoxylum armatum DC. leaves using in vivo and in vitro approaches. For in vivo studies, blood glucose level was monitored at different intervals after administration of varying doses of the extract for its hypoglycemic (100–6000 mg/kg b.w. and antihyperglycemic (250 mg/kg b.w. effect in normoglycemic and diabetic mice. In vitro enzymatic inhibition activity was tested against α-amylase, α- and β-glucosidase and lipase. Additionally hydroxyl radical, hydrogen peroxide scavenging assay and phytochemical screening were also performed. Element analysis of the plant was studied by Atomic Absorption Spectrometry (AAS and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES. The plant extract showed significant hypoglycemic and antihyperglycemic effect in normoglycemic and diabetic mice. The IC50 values of extract for α-amylase, β-glucosidase, lipase, hydroxyl radical scavenging activity, hydrogen peroxide scavenging activity were 7.40 mg/ml, 0.30 mg/ml, 8.35 mg/ml, 3.25 mg/ml, 9.62 mg/ml respectively and the percentage of inhibition for α-glucosidase was 79.82% at 0.8 mg/ml. In vitro studies were compared with their respective standards. Elemental analysis revealed the presence of essential elements such as Mg, V, Fe, Cr, Zn, Cu, Mo, Mn, K, Ca, P and Sr which are all known to play a role in regulating blood glucose. The results demonstrate that Z. armatum aqueous leaves extract possess antidiabetic property in both in vivo and in vitro condition.

  3. Static Analysis of Steel Fiber Concrete Beam With Heterosis Finite Elements

    Directory of Open Access Journals (Sweden)

    James H. Haido

    2014-08-01

    Full Text Available Steel fiber is considered as the most commonly used constructional fibers in concrete structures. The formulation of new nonlinearities to predict the static performance of steel fiber concrete composite structures is considered essential. Present study is devoted to investigate the efficiency of utilizing heterosis finite elements analysis in static analysis of steel fibrous beams. New and simple material nonlinearities are proposed and used in the formulation of these elements. A computer program coded in FORTRAN was developed to perform current finite element static analysis with considering four cases of elements stiffness matrix determination. The results are compared with the experimental data available in literature in terms of central deflections, strains, and failure form, good agreement was found. Suitable outcomes have been observed in present static analysis with using of tangential stiffness matrix and stiffness matrix in second iteration of the load increment.

  4. Elemental analysis of biological materials. Current problems and techniques with special reference to trace elements

    International Nuclear Information System (INIS)

    1980-01-01

    Selected techniques were reviewed for the assay of trace and minor elements in biological materials. Other relevant information is also presented on the need for such analyses, sampling, sample preparation and analytical quality control. In order to evaluate and compare the applicability of the various analytical techniques on a meaningful and objective basis, the materials chosen for consideration were intended to be typical of a wide range of biological matrics of different elemental compositions, namely Bowen's kale, representing a plant material, and NBS bovine liver, IAEA animal muscle, and blood serum, representing animal tissues. The subject is reviewed under the following headings: on the need for trace element analyses in the life sciences (4 papers); sampling and sample preparation for trace element analysis (2 papers); analytical techniques for trace and minor elements in biological materials (7 papers); analytical quality control (2 papers)

  5. Application of the Rutherford backscattering analysis (RBS analysis) for detecting heavy impurity elements in pBN crucible materials

    International Nuclear Information System (INIS)

    Bethge, K.; Meyer, J.D.; Michelmann, R.; Krauskopf, J.

    1992-01-01

    By means of the Rutherford backscattering analysis evidence is given of an inhomogeneous depth distribution of the elements C, O, F, Na, Mg, Al, Si, P, S, Cl, Ca, Ti, Cr, Fe, Ni in pBN (pyrolytic boron nitride) materials of crucibles. This inhomogenous distribution is observed both at the original surface and at the surface of inner cracks. In addition, the distribution of the elements is found to differ depending on the spots chosen for analysis. The RBS measurements alone do not yield information on the volume concentration of the elements. (orig.) With 2 refs [de

  6. The Determination Of Trace Element Levels In Diet By Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Kukuh, Ratnawati; Djojosubroto, Harjoto

    2002-01-01

    Trace element levels in foodstuff are normally low. Although the levels are low, certain trace elements which are called essential trace elements have an important role in metabolism process. Deficiency or intoxication of essential trace elements may lead to abnormal health. In this study the levels of Zn, Fe, AI, Mn, and Co in diet samples were determined by neutron activation analysis, and then the daily intakes of these elements were estimated. The samples were prepared by duplicate diet method, representing those that were consumed by population from West, Central and East Java. Following the collection the respective samples were blended, then were freeze dried at-54 o c. The elemental quantification were performed by neutron activation analysis. The traceability of the determination was ensured using standard reference material NIST-SRM-1548a. The results show that the daily intake for Zn were 2.8-22.8 mg/day (reference value were 5- 40 mg/day), Fe were 3.1-26.5 mg/day (reference value were 6-40 mg/day), AI were 4,2-32.9 mg/day (reference value were 2-45 mg/day), Mn were 1.0-5,6 mg/day (reference value were 0.4-10,0 mg/day), and Co were 0,005-0,074 mg/day (reference value were 0.005 -1.8 mg/day

  7. Trace element determination in soft tissues of marine bivalves by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2003-01-01

    Trace elements in soft tissues of marine bivalves were determined by neutron activation analysis (NAA) and photon activation analysis (PAA). Elemental levels of Ag, As, Br, Co, Cu, Fe, I, Mn, Ni, Rb, Se, and Zn in the organs of giant ezoscallos, rock oysters, and giant crams were obtained. The metal-bound proteins were extracted from the mantles and hepatopancreases of rock oysters. By irradiating the fraction obtained by HPLC gel chromatography, the possibility for the existence of an Ag bound protein in the mantles was found. (author)

  8. Downhole Elemental Analysis with LIBS

    Science.gov (United States)

    Moreschini, Paolo; Zacny, Kris; Rickman, Doug

    2011-01-01

    In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a

  9. Trace elements in cigarette tobacco by a method of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Noordin Ibrahim

    1986-01-01

    A total of ten cigarette brands were investigated for determining the trace elemental concentrations in tobacco so as to assess their role in the induction of related diseases through smoking. A method instrumental Neutron Activation analysis was employed due to high sensitivity, speed and ability to analyse sample for a wide spectrum of elements simultaneously. A total of 18 elements were detected of which the majority are toxic elements. A full result and conclusion will be reported in the forthcoming paper. (A.J.)

  10. Potential interferences inherent in neutron-activation analysis of trace elements in biological materials

    International Nuclear Information System (INIS)

    Cornells, R.; Hoste, J.; Versieck, J.

    1982-01-01

    A comprehensive review is given of how neutron-activation analysis for trace elements in biological matrices can be jeopardized by radiation damage, by the impurities present in the packing material or by nuclear interferences of major elements. Systematic errors during the counting process and the quantitative interpretation of the γ-ray spectra should not be disregarded. (author)

  11. Analysis and characterization of trace elements in shale oil and shale oil products by instrumental neutron activation analysis. Master's thesis

    International Nuclear Information System (INIS)

    Shaw, P.

    1978-12-01

    Trace elements and their mobilization constitute an important consideration in the development of new fossil fuel technologies. Shale oil produced by in situ retorting of oil shale is an alternative fossil energy source. This study deals with the analysis of trace elements in various shale oil products using instrumental neutron activation analysis (INAA). INAA offers several advantages for those elements for which it is applicable. The greatest advantage is the lack of sample preparation prior to analysis, which greatly simplifies the process and prevents sample contamination. The elements for which analyses are reported in this study are aluminum, antimony, arsenic, bromine, cerium, chlorine, chromium, cobalt, copper, gallium, gold, iodine, iron, manganese, mercury, molybdenum, potassium, selenium, sodium, sulfur, tungsten, vanadium, and zinc

  12. Introduction to nonlinear finite element analysis

    CERN Document Server

    Kim, Nam-Ho

    2015-01-01

    This book introduces the key concepts of nonlinear finite element analysis procedures. The book explains the fundamental theories of the field and provides instructions on how to apply the concepts to solving practical engineering problems. Instead of covering many nonlinear problems, the book focuses on three representative problems: nonlinear elasticity, elastoplasticity, and contact problems. The book is written independent of any particular software, but tutorials and examples using four commercial programs are included as appendices: ANSYS, NASTRAN, ABAQUS, and MATLAB. In particular, the MATLAB program includes all source codes so that students can develop their own material models, or different algorithms. This book also: ·         Presents clear explanations of nonlinear finite element analysis for elasticity, elastoplasticity, and contact problems ·         Includes many informative examples of nonlinear analyses so that students can clearly understand the nonlinear theory ·    ...

  13. Investigation of the Behavior of Steel Shear Walls Using Finite Elements Analysis

    Directory of Open Access Journals (Sweden)

    K. Abubakri

    2016-10-01

    Full Text Available Currently, steel shear walls are considered by engineers as an economic method against lateral loads imposed by wind and earthquake in tall structures. Accordingly, there is a growing need to develop accurate methods alongside approximation methods to estimate the behavior of these structural elements. The finite element technique is one of the strongest numerical methods in analysis of solid mechanics problems. Finite element analysis however requires high technical knowledge of the behavioral models of materials. Therefore, it is less used by designers for certain structural elements such as steel shear walls. This study examines the failure mechanism of steel shear walls using finite elements analysis and validates this modeling by comparing the results with experimental studies.

  14. Three dimensional finite element linear analysis of reinforced concrete structures

    International Nuclear Information System (INIS)

    Inbasakaran, M.; Pandarinathan, V.G.; Krishnamoorthy, C.S.

    1979-01-01

    A twenty noded isoparametric reinforced concrete solid element for the three dimensional linear elastic stress analysis of reinforced concrete structures is presented. The reinforcement is directly included as an integral part of the element thus facilitating discretization of the structure independent of the orientation of reinforcement. Concrete stiffness is evaluated by taking 3 x 3 x 3 Gauss integration rule and steel stiffness is evaluated numerically by considering three Gaussian points along the length of reinforcement. The numerical integration for steel stiffness necessiates the conversion of global coordiantes of the Gaussian points to nondimensional local coordinates and this is done by Newton Raphson iterative method. Subroutines for the above formulation have been developed and added to SAP and STAP routines for solving the examples. The validity of the reinforced concrete element is verified by comparison of results from finite element analysis and analytical results. It is concluded that this finite element model provides a valuable analytical tool for the three dimensional elastic stress analysis of concrete structures like beams curved in plan and nuclear containment vessels. (orig.)

  15. Hyperspectral wide gap second derivative analysis for in vivo detection of cervical intraepithelial neoplasia

    Science.gov (United States)

    Zheng, Wenli; Wang, Chaojian; Chang, Shufang; Zhang, Shiwu; Xu, Ronald X.

    2015-12-01

    Hyperspectral reflectance imaging technique has been used for in vivo detection of cervical intraepithelial neoplasia. However, the clinical outcome of this technique is suboptimal owing to multiple limitations such as nonuniform illumination, high-cost and bulky setup, and time-consuming data acquisition and processing. To overcome these limitations, we acquired the hyperspectral data cube in a wavelength ranging from 600 to 800 nm and processed it by a wide gap second derivative analysis method. This method effectively reduced the image artifacts caused by nonuniform illumination and background absorption. Furthermore, with second derivative analysis, only three specific wavelengths (620, 696, and 772 nm) are needed for tissue classification with optimal separability. Clinical feasibility of the proposed image analysis and classification method was tested in a clinical trial where cervical hyperspectral images from three patients were used for classification analysis. Our proposed method successfully classified the cervix tissue into three categories of normal, inflammation and high-grade lesion. These classification results were coincident with those by an experienced gynecology oncologist after applying acetic acid. Our preliminary clinical study has demonstrated the technical feasibility for in vivo and noninvasive detection of cervical neoplasia without acetic acid. Further clinical research is needed in order to establish a large-scale diagnostic database and optimize the tissue classification technique.

  16. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used

  17. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used.

  18. In vivo flow cytometry for blood cell analysis using differential epi-detection of forward scattered light

    Science.gov (United States)

    Paudel, Hari P.; Jung, Yookyung; Raphael, Anthony; Alt, Clemens; Wu, Juwell; Runnels, Judith; Lin, Charles P.

    2018-02-01

    The present standard of blood cell analysis is an invasive procedure requiring the extraction of patient's blood, followed by ex-vivo analysis using a flow cytometer or a hemocytometer. We are developing a noninvasive optical technique that alleviates the need for blood extraction. For in-vivo blood analysis we need a high speed, high resolution and high contrast label-free imaging technique. In this proceeding report, we reported a label-free method based on differential epi-detection of forward scattered light, a method inspired by Jerome Mertz's oblique back-illumination microscopy (OBM) (Ford et al, Nat. Meth. 9(12) 2012). The differential epi-detection of forward light gives phase contrast image at diffraction-limited resolution. Unlike reflection confocal microscopy (RCM), which detects only sharp refractive index variation and suffers from speckle noise, this technique is suitable for detection of subtle variation of refractive index in biological tissue and it provides the shape and the size of cells. A custom built high speed electronic detection circuit board produces a real-time differential signal which yields image contrast based on phase gradient in the sample. We recorded blood flow in-vivo at 17.2k lines per second in line scan mode, or 30 frames per second (full frame), or 120 frame per second (quarter frame) in frame scan mode. The image contrast and speed of line scan data recording show the potential of the system for noninvasive blood cell analysis.

  19. Medical and health-related trace element analysis by TXRF

    International Nuclear Information System (INIS)

    Greaves, E.D.

    2000-01-01

    The advantages offered with TXRF analysis by direct irradiation with monochromatic X-rays of tissue homogenates and body fluids make the technique appropriate for a number of medical and health related applications. The ability to detect low levels of toxic heavy elements is being used as an aid in accidental poisoning diagnosis and treatment, in treatment-induced toxicity control and as an accessory in medical and health research. Thus lead-in-whole-blood analysis is used in confirmation of diagnosis of victims of poisoning, or monitoring the evolution and efficiency of the clinical treatment. Measurement and control of plasma platinum levels of cancer patients undergoing chemotherapy with Pt-containing drugs includes: establishment of the drug level-tumor remission response, measurement of Pt plasma level curves and establishment of optimum dosage to minimize the nephrotoxicity of platinum, and bioequivalence comparisons of different commercially available platinum containing anticancer drugs. Analysis as an aid in clinical research applications includes: trace element determination of amniotic fluid in fetus malformation studies; analysis of brain specimens and cerebrospinal fluid in diagnosis of central nervous system disorders; the influence of trace elements in cataract genesis and the influence of heavy elements in semen quality in human reproduction studies. Human body samples require the use of monochromatized beams of x-rays in order to derive the special advantage of its use: i) The reduction in the spectrum background allowing direct irradiation of organic matter specimens. Hence human tissue and body fluids are prepared by simple procedures involving dilution, homogenization and standard addition avoiding the need for specimen digestion. This results in faster, cheaper methods that decrease sample contamination problems. ii) The presence of a large Compton scattered signal in the spectrum and its use as an internal standard reference allows further

  20. Introduction to finite element analysis using MATLAB and Abaqus

    CERN Document Server

    Khennane, Amar

    2013-01-01

    There are some books that target the theory of the finite element, while others focus on the programming side of things. Introduction to Finite Element Analysis Using MATLAB(R) and Abaqus accomplishes both. This book teaches the first principles of the finite element method. It presents the theory of the finite element method while maintaining a balance between its mathematical formulation, programming implementation, and application using commercial software. The computer implementation is carried out using MATLAB, while the practical applications are carried out in both MATLAB and Abaqus. MA

  1. Finite Element Analysis and Design of Experiments in Engineering Design

    OpenAIRE

    Eriksson, Martin

    1999-01-01

    Projects with the objective of introducing Finite Element Analysis (FEA) into the early phases of the design process have previously been carried out at the Department of Machine Design, see e.g. the Doctoral thesis by Burman [13]. These works clearly highlight the usefulness of introducing design analysis early in the design process. According to Bjärnemo and Burman [10] the most significant advantage of applying design analysis early in the design process was the shift from verification to ...

  2. Structural weights analysis of advanced aerospace vehicles using finite element analysis

    Science.gov (United States)

    Bush, Lance B.; Lentz, Christopher A.; Rehder, John J.; Naftel, J. Chris; Cerro, Jeffrey A.

    1989-01-01

    A conceptual/preliminary level structural design system has been developed for structural integrity analysis and weight estimation of advanced space transportation vehicles. The system includes a three-dimensional interactive geometry modeler, a finite element pre- and post-processor, a finite element analyzer, and a structural sizing program. Inputs to the system include the geometry, surface temperature, material constants, construction methods, and aerodynamic and inertial loads. The results are a sized vehicle structure capable of withstanding the static loads incurred during assembly, transportation, operations, and missions, and a corresponding structural weight. An analysis of the Space Shuttle external tank is included in this paper as a validation and benchmark case of the system.

  3. Application of the neutron activation analysis method for determing trace elements in Brazilian food sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Vasconcellos, M.B.A.

    1988-01-01

    Recently there has been an increase of consciousness about the importance of trace elements in human health and disease as well as rising concern about food contamination. The development of sensitive, accurate and price methods is one of the most important of the knowledge of trace elements contents in foods and in biological samples. Neutron activation analysis is one of the most suitable tecniques because a great number of elements can be determined in concentrations in the range of μg/g to ng/g. The present work is a part of an AIEA Co-ordinated Research Programme on the applications of nuclear techniques for toxic elements in foodstuffs. Neutron activation analysis is applied to analysis of bread, milk powder and rice that are considered essential foods in the Brazilian diet. Some aspects of the activation analysis of biological matrices are discussed. (author) [pt

  4. Study on the dynamics of halogen elements in the agro-environment and these element`s deficiency, toxicity and environmental hazards by the application of the neutron activation analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Yuita, Kouichi [National Inst. of Agro-Environmental Sciences, Tsukuba, Ibaraki (Japan)

    1998-03-01

    A neutron activation analysis method is an accurate and highly sensitive method for analyzing halogen elements (iodine, bromine and chlorine) except fluorine. It is unsubstitutable and valuable method especially for iodine (including radioactive {sup 129}I) and bromine which are present at lower levels. Halogen elements have high chemical and physiological activities and move widely in the environment. As a result, deficiency and an excess of halogen elements in plants and animals have occurred and artificial halogen compounds have caused environmental pollution in wide areas. We efficiently utilized the neutron activation analysis method and an activable tracer method to obtain valuable findings which contribute to the clarification of and measures against these actual problems and which are also concerned with the occurrence, distribution and migration of halogen elements in the environment, especially agricultural and forestry ecosystems in space and in time. (author)

  5. Six key elements' analysis of FAC effective management in nuclear power plant

    International Nuclear Information System (INIS)

    Zhong Zhaojiang; Chen Hanming

    2010-01-01

    Corporate Commitment, Analysis, Operating Experience, Inspection, Training and Engineering Judgment, Long-Term Strategy are the six key elements of FAC effective management in nuclear power plant. Corporate commitment is the economy base of FAC management and ensure of management system, Analysis is the method of FAC's optimization and consummation, Operating experience is the reference and complementarity of FAC, Inspection is the base of accumulating FAC data, Training and engineering judgment is the technical complementarity and deepening, Long-term strategy is successful key of FAC management. Six key elements supplement each other, and make up of a full system of FAC effective management. For present FAC management in our national nuclear power plant, six key elements are the core and bring out the best in each other to found the FAC effective management system and prevent great FAC occurrence. (authors)

  6. Application of neutron activation analysis to the monitoring of trace elements in Brazilian foodstuffs

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.; Maihara, V.A.; Munita, C.J.A.S.; Favaro, D.I.T.; Armelin, M.J.A.

    1994-01-01

    Due to lack of data on trace element levels in Brazilian foodstuffs, nuclear analytical techniques were used to determine about twenty elements in foods samples collected from local markets of the city of Sao Paulo. Drinking water was also analyzed. The methods employed were mainly instrumental and radiochemical neutron activation analysis. In the case of the analysis of toxic elements, such as mercury, selenium, arsenic and antimony, the purely instrumental approach failed in yielding results for very low concentrations of these elements. For INAA, samples and multielemental synthetic standards were irradiated in the IEA R1 research reactor for periods of time ranging from minutes to several hours, under thermal neutron fluxes from 10 11 to 10 13 n·cm -2 ·s -1 ; after suitable cooling times, γ-ray spectra were measured using a Ge(Li) or Ge solid state detector. The RNAA approach involved the distillation of mercury and selenium in HBr medium; selenium was then reduced to the metal form with sodium metabisulphide and mercury was precipitated as sulphide with thioacetamide. For water analysis, a preconcentration procedure based on retention of several elements in a Chelex-100 resin was employed. The elements retained were Hg, Cr, Zn, Fe, Co while Se was measured in the effluent after absorption on active charcoal. The levels of the trace inorganic elements determined in the Brazilian foodstuffs analyzed were always below the levels established by the existing regulations in our country. (author). 16 refs, 18 tabs

  7. In vivo clonal analysis reveals lineage-restricted progenitor characteristics in mammalian kidney development, maintenance, and regeneration

    NARCIS (Netherlands)

    Rinkevich, Y.; Montoro, D.T.; Contreras-Trujillo, H.; Harari-Steinberg, O.; Newman, A.M.; Tsai, J.M.; Lim, X.; van Amerongen, R.; Bowman, A.; Januszyk, M.; Pleniceanu, O.; Nusse, R.; Longaker, M.T.; Weissman, I.L.; Dekel, B.

    2014-01-01

    The mechanism and magnitude by which the mammalian kidney generates and maintains its proximal tubules, distal tubules, and collecting ducts remain controversial. Here, we use long-term in vivo genetic lineage tracing and clonal analysis of individual cells from kidneys undergoing development,

  8. Isogeometric finite element analysis of poroelasticity

    NARCIS (Netherlands)

    Irzal, F.; Remmers, J.J.C.; Verhoosel, C.V.; Borst, de R.

    2013-01-01

    We present an alternative numerical approach for predicting the behaviour of a deformable fluid-saturated porous medium. The conventional finite element technology is replaced by isogeometric analysis that uses non-uniform rational B-splines. The ability of these functions to provide higher-order

  9. Nonlinear nonstationary analysis with the finite element method

    International Nuclear Information System (INIS)

    Vaz, L.E.

    1981-01-01

    In this paper, after some introductory remarks on numerical methods for the integration of initial value problems, the applicability of the finite element method for transient diffusion analysis as well as dynamic and inelastic analysis is discussed, and some examples are presented. (RW) [de

  10. Systematic In Vivo RNAi Analysis Identifies IAPs as NEDD8-E3 Ligases

    DEFF Research Database (Denmark)

    Broemer, Meike; Tenev, Tencho; Rigbolt, Kristoffer T G

    2010-01-01

    -like proteins (UBLs), and deconjugating enzymes that remove the Ub or UBL adduct. Systematic in vivo RNAi analysis identified three NEDD8-specific isopeptidases that, when knocked down, suppress apoptosis. Consistent with the notion that attachment of NEDD8 prevents cell death, genetic ablation of deneddylase 1...

  11. Structural imprints in vivo decode RNA regulatory mechanisms.

    Science.gov (United States)

    Spitale, Robert C; Flynn, Ryan A; Zhang, Qiangfeng Cliff; Crisalli, Pete; Lee, Byron; Jung, Jong-Wha; Kuchelmeister, Hannes Y; Batista, Pedro J; Torre, Eduardo A; Kool, Eric T; Chang, Howard Y

    2015-03-26

    Visualizing the physical basis for molecular behaviour inside living cells is a great challenge for biology. RNAs are central to biological regulation, and the ability of RNA to adopt specific structures intimately controls every step of the gene expression program. However, our understanding of physiological RNA structures is limited; current in vivo RNA structure profiles include only two of the four nucleotides that make up RNA. Here we present a novel biochemical approach, in vivo click selective 2'-hydroxyl acylation and profiling experiment (icSHAPE), which enables the first global view, to our knowledge, of RNA secondary structures in living cells for all four bases. icSHAPE of the mouse embryonic stem cell transcriptome versus purified RNA folded in vitro shows that the structural dynamics of RNA in the cellular environment distinguish different classes of RNAs and regulatory elements. Structural signatures at translational start sites and ribosome pause sites are conserved from in vitro conditions, suggesting that these RNA elements are programmed by sequence. In contrast, focal structural rearrangements in vivo reveal precise interfaces of RNA with RNA-binding proteins or RNA-modification sites that are consistent with atomic-resolution structural data. Such dynamic structural footprints enable accurate prediction of RNA-protein interactions and N(6)-methyladenosine (m(6)A) modification genome wide. These results open the door for structural genomics of RNA in living cells and reveal key physiological structures controlling gene expression.

  12. Low dose human calcium assay in vivo via the 40Ca(n,α) reaction

    International Nuclear Information System (INIS)

    Bigler, R.E.; Laughlin, J.S.; Davis, R. Jr.; Evans, J.C.

    1974-01-01

    A compact medical cyclotron was investigated to elucidate its merit as a neutron source for both qualitative and quantitative activation analysis human studies in vivo of calcium and other elements within the human body and at reasonable radiation dose levels. Emphasis is given to those properties necessary for carrying out quantitative whole body calcium measurements using the 40 (n,α) 37 Ar reaction, which because of the low radiation dose and relatively modest equipment requirements, give this method potential for wide application in diagnostic studies of calcium metabolism. (U.S.)

  13. Low dose human calcium assay in vivo via the 40Ca(n,α) reaction

    International Nuclear Information System (INIS)

    Bigler, R.E.; Davis, R. Jr.; Evans, J.C.

    1974-01-01

    A compact medical cyclotron has been investigated to elucidate its merit as a neutron source for both qualitative and quantitative activation analysis human studies in vivo of calcium and other elements within the human body and at reasonable radiation dose levels. Emphasis is given to those properties necessary for carrying out quantitative whole body calcium measurements using the 40 Ca(n, α) 37 Ar reaction, which because of the low radiation dose and relatively modest equipment requirements, give this method potential for wide application in diagnostic studies of calcium metabolism

  14. Microlocal methods in the analysis of the boundary element method

    DEFF Research Database (Denmark)

    Pedersen, Michael

    1993-01-01

    The application of the boundary element method in numerical analysis is based upon the use of boundary integral operators stemming from multiple layer potentials. The regularity properties of these operators are vital in the development of boundary integral equations and error estimates. We show...

  15. Trace element determination in human bones using the neutron activation analysis method

    International Nuclear Information System (INIS)

    Kramarski, Sila; Saiki, Mitiko; Borelli, Aurelio; Batalha, Joao R.F.

    1997-01-01

    This work presents the results obtained in the analysis of rib bone samples from normal human individuals by applying instrumental neutron activation analysis. In these analyses, the elements Br, Cl, Fe, K, Mg, Na, Rb, Sr and Zn were found at the ppm level and the elements Ca and P at the level of percentage. The precision and the of the results were evaluated by using biological reference materials NIST SRM 1577a Bovine Liver, IAEA A-11 Milk powder, NIES CRM 9 Sargasso e NIES CRM 10A Rice Flour Unpolished. (author). 5 refs., 3 tabs

  16. Finite element stress analysis of brick-mortar masonry under ...

    African Journals Online (AJOL)

    Stress analysis of a brick-mortar couplet as a substitute for brick wall structure has been performed by finite element method, and algorithm for determining the element stiffness matrix for a plane stress problem using the displacement approach was developed. The nodal displacements were derived for the stress in each ...

  17. Multi-element determination in environmental samples by mass spectrometric isotope dilution analysis using thermal ionization. Pt. 2

    International Nuclear Information System (INIS)

    Hilpert, K.; Waidmann, E.

    1988-01-01

    An analytical procedure for the multi-element analysis of the elements Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Ba, Tl, and Pb in pine needles by mass spectrometric isotope dilution analysis using thermal ionization has been reported in Part I of this paper. This procedure is now transferred to the non-vegetable material 'Oyster Tissue' (Standard Reference Material 1566, National Bureau of Standards, USA). By a modification of the analytical procedure, it was possible to determine Cr in this material in addition to the aforementioned elements. No concentrations are certified for the elements Ga, Ba and Tl analyzed in this work. The concentrations of the remaining elements obtained by the multi-element analysis agree well with those certified. (orig.)

  18. Proton induced x-ray emission analysis of trace elements in thick bread samples

    International Nuclear Information System (INIS)

    Mohamed Baker Al-bedri; Ikram Jameel Abdul Ghani; Ibrahim Abdul Rahman Al-aghil

    2009-01-01

    Proton induced X-ray emission (PIXE) technique has been used for identification and quantitative analysis of the elemental concentration in thick bread samples. Bread samples were air-oven dried at 60degC and milled in a clean agate mortar to homogenize the sample and pressed into a pellet. PIXE technique relies on the analysis of the energy spectra of the characteristic X-ray emitted from the thick bread sample and the orchard leaf standard (NIST-SRM-1571) bombarded with 2.0 MeV protons. The concentration of the elements (Cl, K, Ca, Mn, Fe, Cu, and Zn) in the bread samples was determined by comparison with NIST orchard leaf standard. The accuracy of the measurements ranged between ±2% and ±10% for the most elements detected in this method. The aim of this study is to establish the reference concentration of trace elements in the Iraqi bread using PIXE technique. (author)

  19. Trace elemental analysis of the aerosol particulates in northern Punjab

    International Nuclear Information System (INIS)

    Iqbal, M.Z.

    2002-01-01

    Trace elemental analysis of the aerosol particulates was studied in the atmosphere of Lahore, Faisalabad, Islamabad, Sheikhupura, Wah Cantt. And Khanispur. The amount of the aerosol particulates in the above mentioned areas was compared to the U.S. EPA maximum permissible limits. Scavenging mechanism of the aerosol particulates through precipitation was studied in the atmosphere of Lahore and Sheikhupura by using HPLC and ICP-AES techniques. The site distribution and morphological structure of the aerosol particulates was studied by using Scanning Electron Microscope model JSM-35CF. Trace elemental composition of the aerosol particulates in the atmosphere of the selected areas of Pakistan was carried out by using NAA. The elements thus studied were Ce, Yb, Se, Cr, Hf, Cs, Sc, Fe, Co, Eu, Sb, Mo, Ba, Zn, Hg, Br, Na, Gd, Sm, Nd and In while Pb and Cd were estimated by using ASS technique. (author)

  20. Determination of toxic elements in tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yaprak, G.; Cam, N.F.

    1998-01-01

    The concentration of toxic elements in the tobacco of six different brands of domestic and two brands of imported cigarettes heavily smoked in Turkey were determined using instrumental neutron activation analysis (INAA)

  1. Live imaging of companion cells and sieve elements in Arabidopsis leaves.

    Directory of Open Access Journals (Sweden)

    Thibaud Cayla

    Full Text Available The phloem is a complex tissue composed of highly specialized cells with unique subcellular structures and a compact organization that is challenging to study in vivo at cellular resolution. We used confocal scanning laser microscopy and subcellular fluorescent markers in companion cells and sieve elements, for live imaging of the phloem in Arabidopsis leaves. This approach provided a simple framework for identifying phloem cell types unambiguously. It highlighted the compactness of the meshed network of organelles within companion cells. By contrast, within the sieve elements, unknown bodies were observed in association with the PP2-A1:GFP, GFP:RTM1 and RTM2:GFP markers at the cell periphery. The phloem lectin PP2-A1:GFP marker was found in the parietal ground matrix. Its location differed from that of the P-protein filaments, which were visualized with SEOR1:GFP and SEOR2:GFP. PP2-A1:GFP surrounded two types of bodies, one of which was identified as mitochondria. This location suggested that it was embedded within the sieve element clamps, specific structures that may fix the organelles to each another or to the plasma membrane in the sieve tubes. GFP:RTM1 was associated with a class of larger bodies, potentially corresponding to plastids. PP2-A1:GFP was soluble in the cytosol of immature sieve elements. The changes in its subcellular localization during differentiation provide an in vivo blueprint for monitoring this process. The subcellular features obtained with these companion cell and sieve element markers can be used as landmarks for exploring the organization and dynamics of phloem cells in vivo.

  2. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-05-01

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce

  3. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1965-05-15

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce.

  4. Elemental analysis of hair using PIXE-tomography and INAA

    International Nuclear Information System (INIS)

    Beasley, D.; Gomez-Morilla, I.; Spyrou, N.

    2008-01-01

    3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic PIXE analysis to analysis of hair are discussed. The conclusions drawn from the PIXE-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey. (author)

  5. Proton induced X-Ray fluorescence study as a tool trace element analysis

    International Nuclear Information System (INIS)

    El-Kady, Ahmed A.

    1978-01-01

    Usefulness and limitations of trace elemental analysis by high energy charged particles and photon induced X-ray have been discussed. Comparison with the well established neutron activation analysis technique is also given. Back-ground radiation due to bremsstrahlung from secondary electrons and due to charged particle bremsstrahlung have been reviewed for different projectiles. The sensitivity of elemental analysis by proton induced X-ray fluorescence have been examined by measuring the characteristic X-ray emission cross section for K and L transitions of many elements and for different proton energies and compared with theroretical values. The discussion given in this report show that with suitable proton generator and a high resolution X-ray detector, proton X-ray fluorescence technique is capable of analyzing many elements simultaneously at the part per million level and offers a rapid and reliable method for trace element analysis. Data on water, blood and tissue samples given in this report are few examples of many possible applications

  6. Magnesium degradation influenced by buffering salts in concentrations typical of in vitro and in vivo models.

    Science.gov (United States)

    Agha, Nezha Ahmad; Feyerabend, Frank; Mihailova, Boriana; Heidrich, Stefanie; Bismayer, Ulrich; Willumeit-Römer, Regine

    2016-01-01

    Magnesium and its alloys have considerable potential for orthopedic applications. During the degradation process the interface between material and tissue is continuously changing. Moreover, too fast or uncontrolled degradation is detrimental for the outcome in vivo. Therefore in vitro setups utilizing physiological conditions are promising for the material/degradation analysis prior to animal experiments. The aim of this study is to elucidate the influence of inorganic salts contributing to the blood buffering capacity on degradation. Extruded pure magnesium samples were immersed under cell culture conditions for 3 and 10 days. Hank's balanced salt solution without calcium and magnesium (HBSS) plus 10% of fetal bovine serum (FBS) was used as the basic immersion medium. Additionally, different inorganic salts were added with respect to concentration in Dulbecco's modified Eagle's medium (DMEM, in vitro model) and human plasma (in vivo model) to form 12 different immersion media. Influences on the surrounding environment were observed by measuring pH and osmolality. The degradation interface was analyzed by electron-induced X-ray emission (EIXE) spectroscopy, including chemical-element mappings and electron microprobe analysis, as well as Fourier transform infrared reflection micro-spectroscopy (FTIR). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Determination of the elemental content in cigarettes by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Metwally, E.

    2001-01-01

    Cigarette smoking, a worldwide habit, has a very bad and hazardous effect on the human body. Neutron activation analysis technique is used in the present study. Different kinds of cigarette brands have been collected from local and foreign markets representing ten countries all over the world. All the selected samples are irradiated in first Ins has reactor, ER-1 in Egypt. A comprehensive study of the elemental content in cigarette samples under investigation has been carried out. Concentrations of the polluting elements, tracers' content and more than twenty elements have been determined. The obtained data resulting from the present work are discussed

  8. Multi-element analysis of emeralds and associated rocks by k{sub 0} neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B

    2000-12-15

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k{sub 0} method (k{sub 0} INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method.

  9. In vivo studies on the nitrogen, chlorine, calcium and phosphorus composition of rats by neutron activation analysis

    International Nuclear Information System (INIS)

    Morel-Jacrot, Micheline.

    1975-01-01

    The role of neutron activation analysis 'in vivo' to determine the elementary composition of the rat organism is demonstrated. In part one the possibilities offered by certain methods which establish the elementary composition of living organisms are analyzed, together with the contribution and scope of neutron activation analysis. In part two the technical details of the neutron activation of rats in vivo are determined and the problems raised by application of the method considered. This is followed by an application of neutron activation analysis to research on changes in the nitrogen, chlorine, calcium and phosphorus composition of rats during growth (from 30 to 440 days) and important biological events such as puberty in both sexes, reproduction and lactation. Finally a study of the fertility rate and the effects of repeated irradiations on Sprague-Dawley rats are described [fr

  10. Elemental content of Vietnamese rice. Part 2. Multivariate data analysis.

    Science.gov (United States)

    Kokot, S; Phuong, T D

    1999-04-01

    Rice samples were obtained from the Red River region and some other parts of Vietnam as well as from Yanco, Australia. These samples were analysed for 14 elements (P, K, Mg, Ca, Mn, Zn, Fe, Cu, Al, Na, Ni, As, Mo and Cd) by ICP-AES, ICP-MS and FAAS as described in Part 1. This data matrix was then submitted to multivariate data analysis by principal component analysis to investigate the influences of environmental and crop cultivation variables on the elemental content of rice. Results revealed that geographical location, grain variety, seasons and soil conditions are the most likely significant factors causing changes in the elemental content between the rice samples. To assess rice quality according to its elemental content and physio-biological properties, a multicriteria decision making method (PROMETHEE) was applied. With the Vietnamese rice, the sticky rice appeared to contain somewhat higher levels of nutritionally significant elements such as P, K and Mg than the non-sticky rice. Also, rice samples grown during the wet season have better levels of nutritionally significant mineral elements than those of the dry season, but in general, the wet season seemed to provide better overall elemental and physio-biological rice quality.

  11. Statistical Energy Analysis (SEA) and Energy Finite Element Analysis (EFEA) Predictions for a Floor-Equipped Composite Cylinder

    Science.gov (United States)

    Grosveld, Ferdinand W.; Schiller, Noah H.; Cabell, Randolph H.

    2011-01-01

    Comet Enflow is a commercially available, high frequency vibroacoustic analysis software founded on Energy Finite Element Analysis (EFEA) and Energy Boundary Element Analysis (EBEA). Energy Finite Element Analysis (EFEA) was validated on a floor-equipped composite cylinder by comparing EFEA vibroacoustic response predictions with Statistical Energy Analysis (SEA) and experimental results. Statistical Energy Analysis (SEA) predictions were made using the commercial software program VA One 2009 from ESI Group. The frequency region of interest for this study covers the one-third octave bands with center frequencies from 100 Hz to 4000 Hz.

  12. Element analysis of Japanese traditional papers by PIXE method

    International Nuclear Information System (INIS)

    Suzuki, Tatsuya; Yasuda, Keisuke; Tani, Teruhiro

    2000-01-01

    The Japanese papers, 'washi', are made from the bast fibers of the plants. Since washi have the informations of the raw material plants, there is potentiality of the identification of the production place by the element analysis of the washi. Three kinds of washi made of kozo, which have different habitats, were prepared. The elements in their washi were measured by the PIXE. It was confirmed that the amount of elements included in the washi depend on the habitats of their raw material plants. (author)

  13. PIXE and neutron activation analysis: intercomparison in the elemental concentration of airborne particulate matter

    International Nuclear Information System (INIS)

    Cassorla, V.; Rojas, X.; Gras, N.; Chuaqui, L.; Dinator, M.I.; Morales, J.R.; Llona, F.; Romo-Kroeger, C.

    1993-01-01

    Two nuclear analytical techniques, neutron activation analysis (NAA) and proton induced X-ray emission (PIXE), were used to determine major and trace elements in airborne particulate matter collected during the first fortnight of June 1991 at the La Reina Nuclear Center. NAA detected the presence of 15 elements in the samples. PIXE, for the same samples, allowed the detection of 12 elements. The elements determined by both techniques were Al, Ca, Mn, Fe, Cu, and Zn. A good correlation between results for these elements for each of the two techniques was demonstrated. (author)

  14. Advanced chemical analysis service for elements, radionuclides and phases

    International Nuclear Information System (INIS)

    Sansoni, B.

    1986-01-01

    A review is given on the structure, organisation and performance of the chemical analysis service of the Central Department for Chemical Analysis at the Kernforschungsanlage Juelich GmbH. The research and development programs together with the infrastructure of the Centre afford to analyse almost all stable elements of the periodical table in almost any material. The corresponding chemical analysis service has been organized according to a new modular system of analytical steps. According to this, the most complicated and, therefore, most general case of an analytical scheme for element and radionuclide analysis in any type of material can be differentiated into about 14 different steps, the modules. They are more or less independent of the special problem. The laboratory is designed and organized according to these steps. (orig./PW) [de

  15. Determination of trace elements in Turkish tea leaves by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Demiralp, R.

    1986-01-01

    The human body continuously assimilates a variety of inorganic elements from food and the environment. Some of these elements are closely related to human health and disorder. Tea is one of the most popular stimulating beverages which is consumed by low and high income family groups in many countries. Instrumental neutron activation analysis is one of the preferred methods because information on a large number of elements can be obtained simultaneously. Five packets each of the seven commonly used brands of tea were obtained from the market. In order to determine the transfer of trace elements into the drinkable portion about 2-3g. of the tea leaves were boiled in hot water for 2 min. After filtration the used tea leaves were dried at 65 deg. C in an oven and a portion, about 200mg was used for analysis. Samples and standards were irradiated 10 min. and 2 hrs. at pneumatic system and central thimble in the TRIGA MARK-II research reactor. After irradiation, the activities of samples and standards were measured with a aoaxial Ge detector coupled to a spectroscopic amplifier. A Canbera 90 model multi- channel analyzer with an 8K memory was used for pulse height analysis. The system has a resolution of 2.0 KeV. for the 1332.5 KeV gamma ray of 60 Co. The activity of the sample and standard was compared and the element contst of the sample was calculated. (author)

  16. Trace elements in 11 fruits widely-consumed in the USA as determined by neutron activation analysis

    International Nuclear Information System (INIS)

    Michenaud-Rague, A.; Robinson, S.; Landsberger, S.

    2012-01-01

    While there is a lot of information on the elemental content of food for nutritional and pollution studies, the analysis of fruits has received little attention. We have investigated 11 commonly eaten fruits for their trace and minor element constituents by neutron activations including thermal and epithermal neutron activation analysis. Our results revealed that both blueberries and strawberries had the most of top two highest elemental concentrations followed by raspberries, oranges and mango. Bananas, grapes, plums, apples, pears, and cherries had the fewest or none of the most elevated elemental concentrations. (author)

  17. Trace element determination in beauty products by k0-instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Sneyers, L.; Verheyen, L.; Vermaercke, P.; Bruggeman, M.

    2009-01-01

    A recent study on trace elements in beauty products and cosmetics sold on the Asian market has shown the presence of high levels of U, Th and rare earth elements in so called 'Hormesis cosmetics'. For the purpose of comparison, some more information about trace elements in European cosmetics would be useful. In this paper the results obtained using k 0 -standardised Instrumental Neutron Activation Analysis (k 0 -INAA) for more than 20 trace elements in 20 different beauty products collected from the European market are presented. We found traces of Ba, As and Sb which is in breach with European legislation. For some of the other elements like Cr and Co further speciation is needed in order to evaluate their presence in beauty products. (author)

  18. Applications of X-ray emission to elemental analysis of foods

    International Nuclear Information System (INIS)

    Flocchini, R.G.; Lagunas-Solar, M.C.; Perley, B.P.

    1996-01-01

    Trace element analysis via X-Ray Fluorescence (XRF) and Proton-Induced X-Ray Emission (PIXE) techniques were applied to several samples of fresh and processed foods. Thin samples of fresh fruits and vegetables, processed dry foods, and spices were included in these analyses. The results indicate that XRF and/or PIXE analysis is applicable to these types of samples but require special and simple modifications in sample preparation techniques, and the inclusion of new matrix type corrections for data analysis. However, the non-destructive nature, reproducibility, efficiency and high sensitivity that characterize these multi-element analytical procedures can provide new potential methods for detecting trace elements in foods and in many agricultural commodities. Toxic metals such as Hg, Pb, and As were detected in some foods. In addition, other essential or neutral trace elements such as Na, K, Mg, Ca, Cu, Cr, V, Zn, Mo, Fe, Mn, Ni, Se, Cl, S, and P were also detected. These and other elements can be analyzed rapidly and with high sensitivity for applications in process control and for certification of food quality. Developing these techniques and procedures specifically for food and for various agricultural products may provide new analytical options and help mitigate the expected impact of forthcoming regulations intended to establish limits and tolerance levels for micro toxicants and other essential nutrients in foods and agricultural products. (author)

  19. Semianalytic Design Sensitivity Analysis of Nonlinear Structures With a Commercial Finite Element Package

    International Nuclear Information System (INIS)

    Lee, Tae Hee; Yoo, Jung Hun; Choi, Hyeong Cheol

    2002-01-01

    A finite element package is often used as a daily design tool for engineering designers in order to analyze and improve the design. The finite element analysis can provide the responses of a system for given design variables. Although finite element analysis can quite well provide the structural behaviors for given design variables, it cannot provide enough information to improve the design such as design sensitivity coefficients. Design sensitivity analysis is an essential step to predict the change in responses due to a change in design variables and to optimize a system with the aid of the gradient-based optimization techniques. To develop a numerical method of design sensitivity analysis, analytical derivatives that are based on analytical differentiation of the continuous or discrete finite element equations are effective but analytical derivatives are difficult because of the lack of internal information of the commercial finite element package such as shape functions. Therefore, design sensitivity analysis outside of the finite element package is necessary for practical application in an industrial setting. In this paper, the semi-analytic method for design sensitivity analysis is used for the development of the design sensitivity module outside of a commercial finite element package of ANSYS. The direct differentiation method is employed to compute the design derivatives of the response and the pseudo-load for design sensitivity analysis is effectively evaluated by using the design variation of the related internal nodal forces. Especially, we suggest an effective method for stress and nonlinear design sensitivity analyses that is independent of the commercial finite element package is also discussed. Numerical examples are illustrated to show the accuracy and efficiency of the developed method and to provide insights for implementation of the suggested method into other commercial finite element packages

  20. Finite element analysis of car hood for impact test by using ...

    African Journals Online (AJOL)

    Finite element analysis of car hood for impact test by using solidworks software ... high safety and at the same time can be built according to market demands. ... Keywords: finite element analysis; impact test; Solidworks; automation, car hood.

  1. Identification of Se trace element in the soybean using neutron activation analysis

    International Nuclear Information System (INIS)

    Sihombing, E.; Sri Wardani; Hamzah, A.

    1999-01-01

    Neutron Activation Analysis method has been developed as a fast analysis method with high sensitivity, accuracy and precision in determining distribution of element content of various types of seed food materials. In this research the element content of Se was determined by irradiating sample of black and white soybean that can be bought in the market. For determining the content of long decay time element of Se, a samples of 1.3 - 2.3 grams of seed was irradiated within 45 minutes where as for short decay time of Se, the 1,2 - 2,2 grams of seed was irradiated within 30 minutes in the reactor wall. The activated sample, then, was analyzed using gamma spectrometry method. The gamma spectrum was acquired with Hp Ge detector with counting time within 2 - 60 minutes. The results showed that there is a small deviation on Se's quantity of contents with vary between 154,2 and 165,8 ppb

  2. The use of synchrotron radiation for trace element analysis and element mapping by scanning X-ray fluorescence

    International Nuclear Information System (INIS)

    Davies, S.T.

    1983-01-01

    Synchrotron Radiation excited X-Ray Fluorescence is a potentially powerful tool for the routine quantitative chemical analysis of materials, with minimum detection limits typically of the order of a tenth of a ppm, and with the added advantages of simultaneous multi-element detection capability, spatial resolution on a micron scale, large signal to noise ratios and short analysis times. This paper presents a brief review of the use of Synchrotron Radiation in Trace Element Analysis and discusses the requirements for a microprobe for chemical analysis utilising SR. Data obtained at the Synchrotron Radiation Source, Daresbury Laboratory include XRF spectra of standard reference materials and an application of the technique to the study of ion implanted layers in semiconductors is outlined. (author)

  3. Determination of Inorganic Elements in White Rice by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Moon, J. H.; Kim, S. H.; Lim, J. M.; Lee, Y. N.; Chung, Y. S.

    2011-01-01

    Rice is a staple food and provides an important information of mineral supplement as well as a large portion of calorie for Korean. As scientists have focused their researches on health impacts caused by mineral nutrient deficiency and hazardous elements, public concerns about mineral intake by dietary food is rising. The objectives of this study were to determine inorganic elemental contents in white rice by neutron activation analysis(NAA) and to assist the evaluation of nutritional and harmful status for Korean people

  4. PIXE methodology of rare earth element analysis and its applications

    International Nuclear Information System (INIS)

    Ma Xinpei

    1992-01-01

    The Proton Induced X-ray Emission (PIXE) methodology of rare earth element (REEs) analysis is discussed, including the significance of REE analysis, the principle of PIXE applied to REE, selection of characteristic X-ray for Lanthanide series elements, deconvolution of highly over lapped PIXE spectrum and minimum detection limit (MDL) of REEs. Some practical applications are presented. And the specialities of PIXE analysis to the high pure REE chemicals are discussed. (author)

  5. Preliminary Nuclear Analysis for the HANARO Fuel Element with Burnable Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Chul Gyo; Kim, So Young; In, Won Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Burnable absorber is used for reducing reactivity swing and power peaking in high performance research reactors. Development of the HANARO fuel element with burnable absorber was started in the U-Mo fuel development program at HANARO, but detailed full core analysis was not performed because the current HANARO fuel management system is uncertain to analysis the HANARO core with burnable absorber. A sophisticated reactor physics system is required to analysis the core. The McCARD code was selected and the detailed McCARD core models, in which the basic HANARO core model was developed by one of the McCARD developers, are used in this study. The development of nuclear fuel requires a long time and correct developing direction especially by the nuclear analysis. This paper presents a preliminary nuclear analysis to promote the fuel development. Based on the developed fuel, the further nuclear analysis will improve reactor performance and safety. Basic nuclear analysis for the HANARO and the AHR were performed for getting the proper fuel elements with burnable absorber. Addition of 0.3 - 0.4% Cd to the fuel meat is promising for the current HANARO fuel element. Small addition of burnable absorber may not change any fuel characteristics of the HANARO fuel element, but various basic tests and irradiation tests at the HANARO core are required.

  6. Adaptive finite-element ballooning analysis of bipolar ionized fields

    International Nuclear Information System (INIS)

    Al-Hamouz, Z.M.

    1995-01-01

    This paper presents an adaptive finite-element iterative method for the analysis of the ionized field around high-voltage bipolar direct-current (HVDC) transmission line conductors without resort to Deutsch's assumption. A new iterative finite-element ballooning technique is proposed to solve Poisson's equation wherein the commonly used artificial boundary around the transmission line conductors is simulated at infinity. Unlike all attempts reported in the literature for the solution of ionized field, the constancy of the conductors' surface field at the corona onset value is directly implemented in the finite-element formulation. In order to investigate the effectiveness of the proposed method, a laboratory model was built. It has been found that the calculated V-I characteristics and the ground-plane current density agreed well with those measured experimentally. The simplicity in computer programming in addition to the low number of iterations required to achieve convergence characterize this method of analysis

  7. Activation analysis of toxic elements in meat and farinaceous foodstuffs of the Republic of Argentina

    International Nuclear Information System (INIS)

    Resnizky, S.M.; Bertini, L.M.; Moreno, M.A.; Cohen, I.M.; Videtti Piedracoba, N. de; Pla, R.R.; Gomez, C.D.

    1994-01-01

    As a result of the industrial and agrochemical developments, there has been an increase of the environmental pollution. Foodstuffs are one of the ways of incorporating some heavy metals or other contaminants into the human body. So, it is important to know the amount of these elements in the food consumed by the population. Our project on determination of toxic elements in meat and farinaceous food largely consumed in our country, was carried out by neutron activation analysis. Different kinds of flours and noodles were analyzed as farinaceous, and hamburgers and sausages as manufactured meat products. Specific separation methods were developed by radiochemical neutron activation analysis for As, Sb, Se, Hg and Cd. All these separations were based on precipitation or coprecipitation of the elements as sulphides. Other elements such as Fe, Br, Co, Zn, Rb, and also Se, were analyzed using instrumental neutron activation analysis. Using daily intake of analyzed foodstuffs from consumption tables and their average elemental composition, an intake of the studied elements was calculated. The values obtained for toxic elements were lower than the maximum permissible levels in Argentina. The results of this project could serve as a basis of a wider study including more foodstuffs as raw meat and will be used by other research groups. (author). 8 refs, 3 figs, 4 tabs

  8. Trace Element Analysis of Selenium

    International Nuclear Information System (INIS)

    Soliman, M.S.A.

    2010-01-01

    The present thesis divided into four chapters as follows:Chapter (1):This chapter contains an introduction on different oxidation states of organic and inorganic species for selenium in environmental and biological samples, the process for separation of selenium from these samples and the importance of selenium as a component for these samples. Also gives notes about the techniques which are used in the elemental analysis for selenium species and the detection limits for selenium in these techniques, selenium species in human body and the importance of these species in protecting the body from the different types of cancer and the sources of selenium in environmental samples (soil and water) and distribution levels of selenium in these samples.Chapter (2):This chapter is divided into two parts :The first part deals with the sample collection process for environmental samples (underground water, soil) and the wet digestion ( microwave digestion ) process of soil samples. It also contains the theory of work of the closed microwave digestion system.The second part contains detailed information concerning the theoretical considerations of the used analytical techniques. These techniques include Hydride generation - Atomic Absorption Spectrometer (HG-AAS), Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Neutron Activation Analysis (NAA).Chapter (3): This chapter includes the methods of sampling, sample preparation, and sample digesition. The measures of quality assurance are disscused in this chapter. It describes in details the closed microwave digestion technique and the analytical methods used in this study which are present in Central Laboratory for Elemental and Isotopic Analysis (CLEIA) and the Egypt Second Research Reactor (ETRR-2). The described techniques are Atomic Absorption Spectrometer (AAS 6 vario, Analytical Jena GmbH, Germany), JMS-PLASMAX2 Mass Spectrometer (ICP-MS) and the Egypt Second Research Reactor (NAA).

  9. Applications of finite-element scaling analysis in primatology.

    Science.gov (United States)

    Richtsmeier, J T

    1989-01-01

    The study of biological shape in three dimensions using landmark data can now be accomplished using several alternative methods. This report focuses on the use of finite-element scaling analysis in primate craniofacial morphology. The method is particularly useful in its ability to localize the differences between forms, thereby indicating those loci that differ most between specimens. Several examples of this feature are provided from primatological research. Particulars of the methods are also discussed in an attempt to provide the reader with cautionary knowledge for prudent application of the method in future research.

  10. Separation of interfering elements in the neutron activation analysis of lanthanides in geological materials

    International Nuclear Information System (INIS)

    Saiki, M.

    1988-01-01

    A chemical procedure has been developed for the separation of U, Th, Fe, Sc, Na,Ta, and Mo which interfere in the neutron activation analysis of the lanthanide elements in geological materials. This procedure is based on the solvent extraction of interferents using a solution of tetracycline in benzyl alcohol. The lanthanide elements remaining in the aqueous phase are coprecipitated on calcium oxalate or ferric hydroxide for irradiation and subsequent determination by gamma ray spectrometry. The chemical separation procedure was applied in the analysis of lanthanides in two international geological reference materials GSP-1 (USGS), GS-N (CRPG) and in the analysis of a volcanic rock from Pocos de Caldas, MG, Brazil. The sensitivities for all the lanthanides were determined. (author) [pt

  11. Distinct Prion Domain Sequences Ensure Efficient Amyloid Propagation by Promoting Chaperone Binding or Processing In Vivo.

    Directory of Open Access Journals (Sweden)

    Christine R Langlois

    2016-11-01

    Full Text Available Prions are a group of proteins that can adopt a spectrum of metastable conformations in vivo. These alternative states change protein function and are self-replicating and transmissible, creating protein-based elements of inheritance and infectivity. Prion conformational flexibility is encoded in the amino acid composition and sequence of the protein, which dictate its ability not only to form an ordered aggregate known as amyloid but also to maintain and transmit this structure in vivo. But, while we can effectively predict amyloid propensity in vitro, the mechanism by which sequence elements promote prion propagation in vivo remains unclear. In yeast, propagation of the [PSI+] prion, the amyloid form of the Sup35 protein, has been linked to an oligopeptide repeat region of the protein. Here, we demonstrate that this region is composed of separable functional elements, the repeats themselves and a repeat proximal region, which are both required for efficient prion propagation. Changes in the numbers of these elements do not alter the physical properties of Sup35 amyloid, but their presence promotes amyloid fragmentation, and therefore maintenance, by molecular chaperones. Rather than acting redundantly, our observations suggest that these sequence elements make complementary contributions to prion propagation, with the repeat proximal region promoting chaperone binding to and the repeats promoting chaperone processing of Sup35 amyloid.

  12. Determination of trace elements in drinking water by neutron activation analysis

    International Nuclear Information System (INIS)

    Munita, C.S.; Abe, R.M.; Andrade e Silva, L.G. de.

    1988-10-01

    The concentracao of Hg, Cr, Zn, Fe and Co has been determined in fresh drinking water by a combination of preconcentration and neutron activation analysis. In order to preconcentrate the trace metals, a Chelex-100 resin in the NH + - form has been employed and it was not necessary to use special NH 4 + - form has been employed and it was not necessary to use special agents for the adsorption of the elements which are practically quantitatively retained by the resin. The retention of each element during the preconcentration was investigated using radioactive tracers. Selenium is known as a strongly interferent element for the analysis since the (n,Π) produced 75 Se has a Π-line at 0.279 MeV which coincides with the only Π-line of 203 Hg. The separation was made by a selective retention of mercury. After the sample had passed through the resin, the column was transfered to a polythylene envelope and irradiated at a neutron flux of about 5.10 12 ncm -2 s -1 for 8 h. For Hg the resin was irradiated in quartz ampoules. The samples were counted 15 days after the irradiation. The present method is superior to most other Chelex-100 separation procesures where elements of interest are eluted from the resin prior determinations thereby introducing the possibility of additional reagent blanks and incomplete as well as non-reproducible recoveries. (author) [pt

  13. Development of an accelerator based system for in vivo neutron activation analysis measurements of manganese in humans

    Science.gov (United States)

    Arnold, Michelle Lynn

    2001-11-01

    Manganese is required by the human body, but as with many heavy elements, in large amounts it can be toxic, producing a neurological disorder similar to that of Parkinson's Disease. The primary industrial uses of the element are for the manufacturing of steel and alkali batteries. Environmental exposure may occur via drinking water or exhaust emissions from vehicles using gasoline with the manganese containing compound MMT as an antiknock agent (MMT has been approved for use in both Canada and the United States). Preclinical symptoms of toxicity have recently been detected in individuals occupationally exposed to airborne manganese at levels below the present threshold limit value set by the EPA. Evidence also suggests that early detection of manganese toxicity is crucial since once the symptoms have developed past a certain point, the syndrome will continue to progress even if manganese exposure ceases. The development of a system for in vivo neutron activation analysis (IVNAA) measurement of manganese levels was investigated, with the goal being to have a means of monitoring both over exposed and manganese deficient populations. The McMaster KN-accelerator was used to provide low-energy neutrons, activation within an irradiation site occurred via the 55Mn(n,gamma) 56Mn capture reaction, and the 847 keV gamma-rays emitted when 56Mn decayed were measured using one or more Nal(TI) detectors. The present data regarding manganese metabolism and storage within the body are limited, and it is unclear what the optimal measurement site would be to provide a suitable biomarker of past exposure. Therefore the feasibility of IVNAA measurements in three sites was examined---the liver, brain and hand bones. Calibration curves were derived, minimum detectable limits determined and resulting doses calculated for each site (experimentally in the case of the liver and hand bones, and through computer simulations for the brain). Detailed analytical calculations of the 7Li(p,n) 7Be

  14. Analysis of arsenic and some other elements in coal fly ash by X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Ohki, Akira; Nakajima, Tsunenori; Sakaguchi, Yuka; Iwashita, Akira; Takanashi, Hirokazu

    2005-01-01

    Surface characterization of coal fly ash (CFA) was carried out by use of X-ray photoelectron spectroscopy (XPS), especially focusing on the occurrence of As. A peak in the XPS spectrum of CFA was assigned to oxide forms of As(3d). The molar ratios of Al, As, Ca, Fe, and S normalized to Si were obtained from XPS analysis (MR-X). Also, the molar ratios of those elements were calculated from bulk analysis (total element concentration in CFA) (MR-B). The MR-X/MR-B ratio of As was much higher than those of other elements, suggesting that As is highly enriched on the surface of CFA. When eight CFA samples were analyzed, there was an approximate relationship between the MR-X values and MR-B values for As. The leaching of elements from CFA was examined by XPS analysis and by bulk analysis. The leaching tests using EDTA and HNO 3 resulted in a great decrease in the As(3d) peak area; the %leaching of As obtained by XPS analysis was almost equal to that by bulk analysis

  15. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gulovali, M.C.

    1977-01-01

    This study was undertaken to determine the concentration of trace elements in nine different brands of Turkish cigarette tobacco, pipe tobacco and tobacco ash. Instrumental neutron activation analysis was employed, and a gamma-ray spectrometer consisting of 40 cm 3 Ge(Li) detector coupled to 1024 and 4096-channel analyzers were used. Samples were irradiated at a thermal neutron flux of about 10 13 cm -2 sec -1 . Concentrations of Na, K, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Sb, Cs, Ba, La, Ce, Eu, Hf, Hg and Th were determined in tobacco and ash; percent transference of these elements into ash were calculated. It was found out that trace elements in cigarette tobacco are left in the ash but only a small percentage is transferred into the smoke

  16. PIXE analysis of trace and other mineral elements in Romanian dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Moldovan, Maria

    2002-01-01

    Dental composites made of silicates and oxides particles embedded in an organic polymer, show a dynamic evolution but are rather expensive. Recently, the Romanian biomaterial 'Restacril' offered a low-cost alternative. Because the durability of the composite dental fillings depends both on the main chemical composition and on the impurities that may influence the inorganic particles' properties and thus modifying the bio material clinical behaviour, the elemental analysis of the material is necessary for improving its quality. Particle-induced X-ray emission (PIXE), a sensitive method for multielemental trace detection widely used in biomedical applications, allowed us to evidence 21 mineral elements with Z > 14 in some commercial dental composites. Here we evaluate the performances of PIXE for the control of dental composites by carrying out qualitative analysis of three Romanian biomaterials. PIXE measurements on thick composite samples with a flat surface were done with 3 MeV protons at the NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector, 30 mm thick Al absorber foil and integration of beam current. Up to 21 elements with Z > 19 were detected: K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Ga, Sr, Zr, Nb, Ru, Ag, Ba, Yb, Nd, Hf, Au, As and Pb. The orders of magnitude of relative concentrations were evaluated using X-ray yields obtained for another light element thick composite target. The Romanian composites have specific and diverse compositions, containing a great number of minor and trace elements, many of whom are impurities. Use of higher purity raw materials is suggested to reduce the latter and improve the materials' quality. Refinement of X-ray yields by better matching matrixes calculations and use of concentration standards are proposed for quantitative PIXE analysis of the dental composites. (authors)

  17. In vivo 7Li and 19F NMR studies of drugs in the brain

    International Nuclear Information System (INIS)

    Komoroski, Richard A.

    1999-01-01

    For various reasons, it is advantageous to measure the concentration of a psychoactive drug in the brain in vivo. Many drugs contain the element fluorine. Using 19 F NMR spectroscopy, we have studied the psychoactive drugs trifluoperazine and fluoxetine in the brain in vivo. Using 7 Li NMR, it is possible to detect lithium ion, used to treat manic depressive illness. We have measured the concentration and distribution of lithium in both human and rat brain in vivo. Measurement of drug levels in the human brain may provide a measure of therapeutic or toxic effects, as well as insight into drug metabolism and mechanism of action. (author)

  18. Liquid phase microextraction for the analysis of trace elements and their speciation

    International Nuclear Information System (INIS)

    Hu, Bin; He, Man; Chen, Beibei; Xia, Linbo

    2013-01-01

    Trace/ultra-trace elements and their speciation analysis in complex matrices usually require sample preparation procedures to achieve sample clean-up and analyte preconcentration. Sample preparation is often the bottleneck in trace elements and their speciation analysis which has a direct impact on accuracy, precision and limits of detection and is often the rate-determining step of the analytical process. Recent trends in sample preparation include miniaturization, automation, high-throughput performance and reduction in solvent/sample consumption and operation time. Liquid-phase microextraction (LPME) technique as a novel and promising alternative in sample preparation can meet these requirements and has become a very efficient sample preparation technique. This review updates the state of art of LPME for trace elements and their speciation analysis and discusses its promising prospects. The major thrust of the article highlights the applications of LPME including single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME) to the fields of elemental and their speciation analysis by atomic spectrometry-based methods, especially inductively coupled plasma mass spectrometry. General and specific concepts, different extraction formats and characteristics of LPME are described and compared, along with examples of recent innovations and applications presented to demonstrate its potential for trace elements and their speciation analysis in biological and environmental fields. Moreover, the application potential and an outlook on the combination of LPME and atomic spectrometry-based techniques for inorganic analysis are commentated. - Highlights: • The state of art of LPME for trace elements and their speciation analysis is updated. • Different extraction formats of LPME are described. • The application potential and future

  19. Finite element analysis of beam-to-column joints in steel frames under cyclic loading

    Directory of Open Access Journals (Sweden)

    Elsayed Mashaly

    2011-03-01

    Full Text Available The aim of this paper is to present a simple and accurate three-dimensional (3D finite element model (FE capable of predicting the actual behavior of beam-to-column joints in steel frames subjected to lateral loads. The software package ANSYS is used to model the joint. The bolted extended-end-plate connection was chosen as an important type of beam–column joints. The extended-end-plate connection is chosen for its complexity in the analysis and behavior due to the number of connection components and their inheritable non-linear behavior. Two experimental tests in the literature were chosen to verify the finite element model. The results of both the experimental and the proposed finite element were compared. One of these tests was monotonically loaded, whereas the second was cyclically loaded. The finite element model is improved to enhance the defects of the finite element model used. These defects are; the long time need for the analysis and the inability of the contact element type to follow the behavior of moment–rotation curve under cyclic loading. As a contact element, the surface-to-surface element is used instead of node-to-node element to enhance the model. The FE results show good correlation with the experimental one. An attempt to improve a new technique for modeling bolts is conducted. The results show that this technique is supposed to avoid the defects above, give much less elements number and less solution time than the other modeling techniques.

  20. Determination of trace elements in airborne particulates by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Cho, Seung Yun

    1995-01-01

    Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis(INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux, 1 x 10 13 n/cm 2 s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 were chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different countries. In the analytical result of two or both of standard reference materials, relative standard deviation was within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at two different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources. 3 figs., 8 tabs., 19 refs. (Author)

  1. Determination of trace element impurities in aspirin tablets by neutron activation analysis

    International Nuclear Information System (INIS)

    Iskander, F.Y.; Klein, D.E.; Bauer, T.L.

    1986-01-01

    Twenty-five trace and minor elements in five different Egyptian aspirin brands (Aspo, Askin, Aspocid, Aspeol and Rivo) were determined by instrumental neutron activation analysis. It was concluded that the concentration of As, Ba, Br, Co, Cr, Fe (except in Aspocid), Mg, Mn, Rb, Se, Sr and Zn in the Egyptian brands is below or within the concentration range reported for these elements in 16 American aspirin and aspirin-like brands. (author)

  2. Investigation of the Behavior of Steel Shear Walls Using Finite Elements Analysis

    OpenAIRE

    Abubakri, K.; Veladi, H.

    2016-01-01

    Currently, steel shear walls are considered by engineers as an economic method against lateral loads imposed by wind and earthquake in tall structures. Accordingly, there is a growing need to develop accurate methods alongside approximation methods to estimate the behavior of these structural elements. The finite element technique is one of the strongest numerical methods in analysis of solid mechanics problems. Finite element analysis however requires high technical knowledge of the behavior...

  3. Analysis of the in vivo confocal Raman spectral variability in human skin

    Science.gov (United States)

    Mogilevych, Borys; dos Santos, Laurita; Rangel, Joao L.; Grancianinov, Karen J. S.; Sousa, Mariane P.; Martin, Airton A.

    2015-06-01

    Biochemical composition of the skin changes in each layer and, therefore, the skin spectral profile vary with the depth. In this work, in vivo Confocal Raman spectroscopy studies were performed at different skin regions and depth profile (from the surface down to 10 μm) of the stratum corneum, to verify the variability and reproducibility of the intra- and interindividual Raman data. The Raman spectra were collected from seven healthy female study participants using a confocal Raman system from Rivers Diagnostic, with 785 nm excitation line and a CCD detector. Measurements were performed in the volar forearm region, at three different points at different depth, with the step of 2 μm. For each depth point, three spectra were acquired. Data analysis included the descriptive statistics (mean, standard deviation and residual) and Pearson's correlation coefficient calculation. Our results show that inter-individual variability is higher than intraindividual variability, and variability inside the SC is higher than on the skin surface. In all these cases we obtained r values, higher than 0.94, which correspond to high correlation between Raman spectra. It reinforces the possibility of the data reproducibility and direct comparison of in vivo results obtained with different study participants of the same age group and phototype.

  4. Accumulation and in vivo tissue distribution of pollutant elements in Erica andevalensis

    International Nuclear Information System (INIS)

    Rossini Oliva, S.; Valdes, B.; Leidi, E.O.

    2009-01-01

    Erica andevalensis is an endemic shrub from an area in the southwest of Spain (Andalucia) characterized by acidic and contaminated soils. Scanning electron microscopy (SEM) of samples after conventional or cryo-fixation preparation protocols was used for morphological and anatomical studies. SEM coupled with EDX-analysis was employed to localise and quantify different elements within plant parts (leaves, stems and roots) in samples collected in the field. Morphological studies revealed that the species has typical adaptive structures to drought-stress such as rolled needle-like leaves, sunken stomata and a thick waxy cuticle on the upper epidermis. Roots were associated with fungi which formed intra and extra-cellular mycelia. The SEM studies showed that Cu was not sequestrated into the root tissues and was uniformly distributed in leaf tissues. Meanwhile, Pb was only localised within epidermal root tissues which indicates that its sequestration in an external matrix might represent a tolerance mechanism in this species. Iron was uniformly distributed throughout the leaves, while in roots it was predominantly retained on the epidermal cell walls. The exclusion and tolerance mechanisms adopted by this species to survive in mining areas indicate that it can be used successfully in the re-vegetation of contaminated areas

  5. Accumulation and in vivo tissue distribution of pollutant elements in Erica andevalensis

    Energy Technology Data Exchange (ETDEWEB)

    Rossini Oliva, S. [Department of Plant Biology and Ecology, University of Seville, Avda. Reina Mercedes s/n, Apartado de Correo 1095, 41080 Sevilla (Spain)], E-mail: sabina@us.es; Valdes, B. [Department of Plant Biology and Ecology, University of Seville, Avda. Reina Mercedes s/n, Apartado de Correo 1095, 41080 Sevilla (Spain); Leidi, E.O. [Department of Plant Biotechnology, IRNAS-CSIC, Avda. Reina Mercedes 10, 41012 Sevilla (Spain)

    2009-03-01

    Erica andevalensis is an endemic shrub from an area in the southwest of Spain (Andalucia) characterized by acidic and contaminated soils. Scanning electron microscopy (SEM) of samples after conventional or cryo-fixation preparation protocols was used for morphological and anatomical studies. SEM coupled with EDX-analysis was employed to localise and quantify different elements within plant parts (leaves, stems and roots) in samples collected in the field. Morphological studies revealed that the species has typical adaptive structures to drought-stress such as rolled needle-like leaves, sunken stomata and a thick waxy cuticle on the upper epidermis. Roots were associated with fungi which formed intra and extra-cellular mycelia. The SEM studies showed that Cu was not sequestrated into the root tissues and was uniformly distributed in leaf tissues. Meanwhile, Pb was only localised within epidermal root tissues which indicates that its sequestration in an external matrix might represent a tolerance mechanism in this species. Iron was uniformly distributed throughout the leaves, while in roots it was predominantly retained on the epidermal cell walls. The exclusion and tolerance mechanisms adopted by this species to survive in mining areas indicate that it can be used successfully in the re-vegetation of contaminated areas.

  6. Probabilistic finite elements for fracture and fatigue analysis

    Science.gov (United States)

    Liu, W. K.; Belytschko, T.; Lawrence, M.; Besterfield, G. H.

    1989-01-01

    The fusion of the probabilistic finite element method (PFEM) and reliability analysis for probabilistic fracture mechanics (PFM) is presented. A comprehensive method for determining the probability of fatigue failure for curved crack growth was developed. The criterion for failure or performance function is stated as: the fatigue life of a component must exceed the service life of the component; otherwise failure will occur. An enriched element that has the near-crack-tip singular strain field embedded in the element is used to formulate the equilibrium equation and solve for the stress intensity factors at the crack-tip. Performance and accuracy of the method is demonstrated on a classical mode 1 fatigue problem.

  7. Determination of oral mucosal Poisson's ratio and coefficient of friction from in-vivo contact pressure measurements.

    Science.gov (United States)

    Chen, Junning; Suenaga, Hanako; Hogg, Michael; Li, Wei; Swain, Michael; Li, Qing

    2016-01-01

    Despite their considerable importance to biomechanics, there are no existing methods available to directly measure apparent Poisson's ratio and friction coefficient of oral mucosa. This study aimed to develop an inverse procedure to determine these two biomechanical parameters by utilizing in vivo experiment of contact pressure between partial denture and beneath mucosa through nonlinear finite element (FE) analysis and surrogate response surface (RS) modelling technique. First, the in vivo denture-mucosa contact pressure was measured by a tactile electronic sensing sheet. Second, a 3D FE model was constructed based on the patient CT images. Third, a range of apparent Poisson's ratios and the coefficients of friction from literature was considered as the design variables in a series of FE runs for constructing a RS surrogate model. Finally, the discrepancy between computed in silico and measured in vivo results was minimized to identify the best matching Poisson's ratio and coefficient of friction. The established non-invasive methodology was demonstrated effective to identify such biomechanical parameters of oral mucosa and can be potentially used for determining the biomaterial properties of other soft biological tissues.

  8. Seismic analysis of the APR1400 nuclear reactor system using a verified beam element model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong-beom [Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722 (Korea, Republic of); Park, No-Cheol, E-mail: pnch@yonsei.ac.kr [Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722 (Korea, Republic of); Lee, Sang-Jeong; Park, Young-Pil [Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722 (Korea, Republic of); Choi, Youngin [Korea Institute of Nuclear Safety, 62 Gwahak-ro, Yuseong-gu, Daejeon 34142 (Korea, Republic of)

    2017-03-15

    Highlights: • A simplified beam element model is constructed based on the real dynamic characteristics of the APR1400. • Time history analysis is performed to calculate the seismic responses of the structures. • Large deformations can be observed at the in-phase mode of reactor vessel and core support barrel. - Abstract: Structural integrity is the first priority in the design of nuclear reactor internal structures. In particular, nuclear reactor internals should be designed to endure external forces, such as those due to earthquakes. Many researchers have performed finite element analyses to meet these design requirements. Generally, a seismic analysis model should reflect the dynamic characteristics of the target system. However, seismic analysis based on the finite element method requires long computation times as well as huge storage space. In this research, a beam element model was developed and confirmed based on the real dynamic characteristics of an advanced pressurized water nuclear reactor 1400 (APR1400) system. That verification process enhances the accuracy of the finite element analysis using the beam elements, remarkably. Also, the beam element model reduces seismic analysis costs. Therefore, the beam element model was used to perform the seismic analysis. Then, the safety of the APR1400 was assessed based on a seismic analysis of the time history responses of its structures. Thus, efficient, accurate seismic analysis was demonstrated using the proposed beam element model.

  9. Seismic analysis of the APR1400 nuclear reactor system using a verified beam element model

    International Nuclear Information System (INIS)

    Park, Jong-beom; Park, No-Cheol; Lee, Sang-Jeong; Park, Young-Pil; Choi, Youngin

    2017-01-01

    Highlights: • A simplified beam element model is constructed based on the real dynamic characteristics of the APR1400. • Time history analysis is performed to calculate the seismic responses of the structures. • Large deformations can be observed at the in-phase mode of reactor vessel and core support barrel. - Abstract: Structural integrity is the first priority in the design of nuclear reactor internal structures. In particular, nuclear reactor internals should be designed to endure external forces, such as those due to earthquakes. Many researchers have performed finite element analyses to meet these design requirements. Generally, a seismic analysis model should reflect the dynamic characteristics of the target system. However, seismic analysis based on the finite element method requires long computation times as well as huge storage space. In this research, a beam element model was developed and confirmed based on the real dynamic characteristics of an advanced pressurized water nuclear reactor 1400 (APR1400) system. That verification process enhances the accuracy of the finite element analysis using the beam elements, remarkably. Also, the beam element model reduces seismic analysis costs. Therefore, the beam element model was used to perform the seismic analysis. Then, the safety of the APR1400 was assessed based on a seismic analysis of the time history responses of its structures. Thus, efficient, accurate seismic analysis was demonstrated using the proposed beam element model.

  10. Investigation of faulted tunnel models by combined photoelasticity and finite element analysis

    International Nuclear Information System (INIS)

    Ladkany, S.G.; Huang, Yuping

    1994-01-01

    Models of square and circular tunnels with short faults cutting through their surfaces are investigated by photoelasticity. These models, when duplicated by finite element analysis can predict the stress states of square or circular faulted tunnels adequately. Finite element analysis, using gap elements, may be used to investigate full size faulted tunnel system

  11. The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience

    International Nuclear Information System (INIS)

    Halter, Ryan J; Zhou, Tian; Meaney, Paul M; Hartov, Alex; Barth, Richard J Jr; Rosenkranz, Kari M; Wells, Wendy A; Kogel, Christine A; Borsic, Andrea; Rizzo, Elizabeth J; Paulsen, Keith D

    2009-01-01

    Electromagnetic (EM) breast imaging provides low-cost, safe and potentially a more specific modality for cancer detection than conventional imaging systems. A primary difficulty in validating these EM imaging modalities is that the true dielectric property values of the particular breast being imaged are not readily available on an individual subject basis. Here, we describe our initial experience in seeking to correlate tomographic EM imaging studies with discrete point spectroscopy measurements of the dielectric properties of breast tissue. The protocol we have developed involves measurement of in vivo tissue properties during partial and full mastectomy procedures in the operating room (OR) followed by ex vivo tissue property recordings in the same locations in the excised tissue specimens in the pathology laboratory immediately after resection. We have successfully applied all of the elements of this validation protocol in a series of six women with cancer diagnoses. Conductivity and permittivity gauged from ex vivo samples over the frequency range 100 Hz–8.5 GHz are found to be similar to those reported in the literature. A decrease in both conductivity and permittivity is observed when these properties are gauged from ex vivo samples instead of in vivo. We present these results in addition to a case study demonstrating how discrete point spectroscopy measurements of the tissue can be correlated and used to validate EM imaging studies

  12. Elemental analysis in bed sediment samples of Karnafuli estuarine zone in the Bay of Bengal by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Molla, N.I.; Hossain, S.M.; Basunia, S.; Miah, R.U.; Rahman, M.; Sikder, D.H.; Chowdhury, M.I.

    1997-01-01

    The concentration of rare earths and other elements have been determined in the bed sediment samples of Karnafuli estuarine zone in the Bay of Bengal by instrumental neutron activation analysis (INAA). The samples and the standards soil-5, soil-7, coal fly ash and pond sediment were prepared and simultaneously irradiated for short and long time at the TRIGA Mark-II research reactor facility of Atomic Energy Research Establishment, Savar, Dhaka. The maximum thermal neutron flux was of the order of 10 13 n x cm -2 x s -1 . After irradiation the radioactivity of the product nuclides was measured by using a high resolution high purity germanium detector system. Analysis of γ-ray spectra and quantitative analysis of the elemental concentration were done via the software GANAAS. It has been possible to determine the concentration level of 27 elements including the rare earths La, Ce, Sm, Eu, Tb, Dy and Yb and uranium and thorium. (author)

  13. Proposal for element size and time increment selection guideline by 3-D finite element method for elastic waves propagation analysis

    International Nuclear Information System (INIS)

    Ishida, Hitoshi; Meshii, Toshiyuki

    2008-01-01

    This paper proposes a guideline for selection of element size and time increment by 3-D finite element method, which is applied to elastic wave propagation analysis for a long distance of a large structure. An element size and a time increment are determined by quantitative evaluation of strain, which must be 0 on the analysis model with a uniform motion, caused by spatial and time discretization. (author)

  14. Research on the relationship between the elements and pharmacological activities in velvet antler using factor analysis and cluster analysis

    Science.gov (United States)

    Zhou, Libing

    2017-04-01

    Velvet antler has certain effect on improving the body's immune cells and the regulation of immune system function, nervous system, anti-stress, anti-aging and osteoporosis. It has medicinal applications to treat a wide range of diseases such as tissue wound healing, anti-tumor, cardiovascular disease, et al. Therefore, the research on the relationship between pharmacological activities and elements in velvet antler is of great significance. The objective of this study was to comprehensively evaluate 15 kinds of elements in different varieties of velvet antlers and study on the relationship between the elements and traditional Chinese medicine efficacy for the human. The factor analysis and the factor cluster analysis methods were used to analyze the data of elements in the sika velvet antler, cervus elaphus linnaeus, flower horse hybrid velvet antler, apiti (elk) velvet antler, male reindeer velvet antler and find out the relationship between 15 kinds of elements including Ca, P, Mg, Na, K, Fe, Cu, Mn, Al, Ba, Co, Sr, Cr, Zn and Ni. Combining with MATLAB2010 and SPSS software, the chemometrics methods were made on the relationship between the elements in velvet antler and the pharmacological activities. The first commonality factor F1 had greater load on the indexes of Ca, P, Mg, Co, Sr and Ni, and the second commonality factor F2 had greater load on the indexes of K, Mn, Zn and Cr, and the third commonality factor F3 had greater load on the indexes of Na, Cu and Ba, and the fourth commonality factor F4 had greater load on the indexes of Fe and Al. 15 kinds of elements in velvet antler in the order were elk velvet antler>flower horse hybrid velvet antler>cervus elaphus linnaeus>sika velvet antler>male reindeer velvet antler. Based on the factor analysis and the factor cluster analysis, a model for evaluating traditional Chinese medicine quality was constructed. These studies provide the scientific base and theoretical foundation for the future large-scale rational

  15. Upstand Finite Element Analysis of Slab Bridges

    OpenAIRE

    O'Brien, Eugene J.; Keogh, D.L.

    1998-01-01

    For slab bridge decks with wide transverse edge cantilevers, the plane grillage analogy is shown to be an inaccurate method of linear elastic analysis due to variations in the vertical position of the neutral axis. The upstand grillage analogy is also shown to give inaccurate results, this time due to inappropriate modelling of in-plane distortions. An alternative method, known as upstand finite element analysis, is proposed which is sufficiently simple to be used on an everyday basis in the ...

  16. Determination of trace elements: Neutron-activation analysis in geochemistry and cosmochemistry

    International Nuclear Information System (INIS)

    Kolesov, G.M.

    1994-01-01

    Geochemistry, like cosmochemistry, open-quotes studies chemical elements hor-ellipsis of the crust and hor-ellipsis the Earth hor-ellipsis their history, their distribution hor-ellipsis their genetic hor-ellipsis connectionsclose quotes and is based on data on the abundance and distribution of elements obtained by various analytical methods. Neutron-activation analysis (NAA) plays a particular role in this respect. This is due to its high sensitivity (detection limit as small as 10 -14 g), which makes possible the use of samples of arbitrary mass, and also due to the possibility of obtaining information about composition without destruction of the object, conserving, if required, the unique material under investigation. Of the most interest are the data on the contents for a number of trace elements (at a level of 10 -7 - 10 -4 %), among which are rare-earth elements (REE), U, Th, Zr, Hf, Ta, W, Ga, Ni, Rb, Cs, platinum-group metals, Ag, Au, etc. These elements are considered as indicators of geochemical processes associated with the genesis and evolution of solar system bodies in early and more recent stages of evolution; they are also used to study processes and phenomena at zone boundaries: river-sea, ocean-atmosphere, and so on. The aim of this work is to show the capabilities of NAA in the determination of trace elements

  17. Geospatial analysis of residential proximity to open-pit coal mining areas in relation to micronuclei frequency, particulate matter concentration, and elemental enrichment factors.

    Science.gov (United States)

    Espitia-Pérez, Lyda; Arteaga-Pertuz, Marcia; Soto, José Salvador; Espitia-Pérez, Pedro; Salcedo-Arteaga, Shirley; Pastor-Sierra, Karina; Galeano-Páez, Claudia; Brango, Hugo; da Silva, Juliana; Henriques, João A P

    2018-05-03

    During coal surface mining, several activities such as drilling, blasting, loading, and transport produce large quantities of particulate matter (PM) that is directly emitted into the atmosphere. Occupational exposure to this PM has been associated with an increase of DNA damage, but there is a scarcity of data examining the impact of these industrial operations in cytogenetic endpoints frequency and cancer risk of potentially exposed surrounding populations. In this study, we used a Geographic Information Systems (GIS) approach and Inverse Distance Weighting (IDW) methods to perform a spatial and statistical analysis to explore whether exposure to PM 2.5 and PM 10 pollution, and additional factors, including the enrichment of the PM with inorganic elements, contribute to cytogenetic damage in residents living in proximity to an open-pit coal mining area. Results showed a spatial relationship between exposure to elevated concentrations of PM 2.5, PM 10 and micronuclei frequency in binucleated (MNBN) and mononucleated (MNMONO) cells. Active pits, disposal, and storage areas could be identified as the possible emission sources of combustion elements. Mining activities were also correlated with increased concentrations of highly enriched elements like S, Cu and Cr in the atmosphere, corroborating its role in the inorganic elements pollution around coal mines. Elements enriched in the PM 2.5 fraction contributed to increasing of MNBN but seems to be more related to increased MNMONO frequencies and DNA damage accumulated in vivo. The combined use of GIS and IDW methods could represent an important tool for monitoring potential cancer risk associated to dynamically distributed variables like the PM. Copyright © 2018. Published by Elsevier Ltd.

  18. Experimental and finite element analysis of bond-slip in reinforced concrete

    Directory of Open Access Journals (Sweden)

    A. R. V. WOLENSKI

    Full Text Available Abstract The modeling of reinforced concrete structures has taken advantage of the increasing progress on Computational Mechanics, in such way that complex phenomena, such as cracking and crushing, creep, reinforcement yielding, steel-concrete bond loss, can be modeled in a reasonable realistic way, using the proper set of numerical and computational resources. Among several options, the ones based on the Finite Element Method (FEM allow complex analysis simulations of reinforced concrete structures, including the interaction of different nonlinear effects. This paper deals with the nonlinear finite element analysis of the bond-slip between reinforcing steel and concrete, taking into account an experimental study previously performed. The FEM analysis presented uses a combination of resources where the material behavior of concrete is described by the Microplane Constitutive Model, and an embedded reinforcement model is used to represent steel inside the concrete and take into account the effect of bond-slip. The FEM models were created using the INSANE (INteractive Structural ANalysis Environment computational system, open source software that has a set of FEM tools for nonlinear analysis of reinforced concrete structures. The correlations between numerical-experimentals results and several parameters validate the proposed combination of resources and identifies the significance of various effects on the response.

  19. Elemental analysis of Oum er Rbia Moroccan river-water using TXRF

    International Nuclear Information System (INIS)

    Zahry, F.; Bounakhla, M.; El Hamdaoui, A.; Labraimi, M.

    2000-01-01

    The x-ray fluorescence analysis of water and suspended particulate matter (SPM) from Oum er Rbia Moroccan river for the content of 17 elements has been performed utilizing the energy dispersive x-ray fluorescence spectrometer and total reflection excitation. SPM samples were dissolved in nitric acid. For all samples direct measurements are feasible by spiking a few ml of the sample with Ga as internal standard element, and drying an aliquot of 20 μl on a quartz glass carrier. The detection limits of 10 to 20 ppb are sufficient for most of the elements to be determined. Results were assessed for accuracy by the analysis of the 15474 ICP multi-elemental standard I. Some results were also compared with AAS and ICP-AES. The results for most of the elements obtained by TXRF were accurate to about 2-15 %. The objectives of the analysis were to determine the geo-chemical areas on this river, to explain the mechanism of sediment transport and to assess the pollution of the river by human activities. 36 samples had been collected along the river between its source in Middle Atlas and the Atlantic ocean at Azemour city. (author)

  20. Finite element elastic-plastic analysis of LMFBR components

    International Nuclear Information System (INIS)

    Levy, A.; Pifko, A.; Armen, H. Jr.

    1978-01-01

    The present effort involves the development of computationally efficient finite element methods for accurately predicting the isothermal elastic-plastic three-dimensional response of thick and thin shell structures subjected to mechanical and thermal loads. This work will be used as the basis for further development of analytical tools to be used to verify the structural integrity of liquid metal fast breeder reactor (LMFBR) components. The methods presented here have been implemented into the three-dimensional solid element module (HEX) of the Grumman PLANS finite element program. These methods include the use of optimal stress points as well as a variable number of stress points within an element. This allows monitoring the stress history at many points within an element and hence provides an accurate representation of the elastic-plastic boundary using a minimum number of degrees of freedom. Also included is an improved thermal stress analysis capability in which the temperature variation and corresponding thermal strain variation are represented by the same functional form as the displacement variation. Various problems are used to demonstrate these improved capabilities. (Auth.)

  1. A finite-element for the analysis of shell intersections

    International Nuclear Information System (INIS)

    Koves, W.J.; Nair, S.

    1994-01-01

    The analysis of discontinuity stresses at shell intersections is a problem of great importance in several major industries. Some of the major areas of interest are pressure-containing equipment, such as reactors and piping, in the nuclear and fossil power industry; pressure vessels and heat exchangers in the petrochemical industry; bracing in offshore oil platforms; and aerospace structures. A specialized shell-intersection finite element, which is compatible with adjoining shell elements, has been developed that has the capability of physically representing the complex three-dimensional geometry and stress state at shell intersections. The element geometry is a contoured shape that matches a wide variety of practical nozzle configurations used in ASME Code pressure vessel construction, and allows computational rigor. A closed-form theory of elasticity solution was used to compute the stress state and strain energy in the element. The concept of an energy-equivalent nodal displacement and force vector set was then developed to allow complete compatibility with adjoining shell elements and retain the analytical rigor within the element. This methodology provides a powerful and robust computation scheme that maintains the computational efficiency of shell element solutions. The shell-intersection element was then applied to the cylinder-sphere and cylinder-cylinder intersection problems

  2. Global and local approaches to population analysis: Bonding patterns in superheavy element compounds

    Science.gov (United States)

    Oleynichenko, Alexander; Zaitsevskii, Andréi; Romanov, Stepan; Skripnikov, Leonid V.; Titov, Anatoly V.

    2018-03-01

    Relativistic effective atomic configurations of superheavy elements Cn, Nh and Fl and their lighter homologues (Hg, Tl and Pb) in their simple compounds with fluorine and oxygen are determined using the analysis of local properties of molecular Kohn-Sham density matrices in the vicinity of heavy nuclei. The difference in populations of atomic spinors with the same orbital angular momentum and different total angular momenta is demonstrated to be essential for understanding the peculiarities of chemical bonding in superheavy element compounds. The results are fully compatible with those obtained by the relativistic iterative version of conventional projection analysis of global density matrices.

  3. Elemental analysis of two Egyptian iron ores and produced industrial iron samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Sroor, A.; Abdel-Basset, N.; Abdel-Haleem, A.S.; Hassan, A.M.

    2001-01-01

    Elemental analysis of two iron ores and initial industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were performed by the instrumental neutron activation analysis technique. Five samples of each type were irradiated for 48 h in a thermal neutron flux of 4x10 12 n/cm 2 s in the first Egyptian research reactor ET-RR-1. Also, the Pneumatic Irradiation Rabbit System (PIRS), attached to the reactor ET-RR-1 in Inshass, was used to measure short-life elements. The γ-ray spectra were obtained with a hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. Implications of the elemental concentration values obtained are presented

  4. A New Approach to Sequence Analysis Exemplified by Identification of cis-Elements in Abscisic Acid Inducible Promoters

    DEFF Research Database (Denmark)

    Busk, Peter Kamp; Hallin, Peter Fischer; Salomon, Jesper

    -regulatory elements. We have developed a method for identifying short, conserved motifs in biological sequences such as proteins, DNA and RNA5. This method was used for analysis of approximately 2000 Arabidopsis thaliana promoters that have been shown by DNA array analysis to be induced by abscisic acid6....... These promoters were compared to 28000 promoters that are not induced by abscisic acid. The analysis identified previously described ABA-inducible promoter elements such as ABRE, CE3 and CRT1 but also new cis-elements were found. Furthermore, the list of DNA elements could be used to predict ABA...

  5. Trace element analysis in liquids by proton induced x-ray emission

    International Nuclear Information System (INIS)

    Deconninck, G.

    Proton induced x-ray emission (PIXE) from liquid has been developed for quantitative and simultaneous analysis of trace elements. Liquid drops and trickles are bombarded at atmospheric pressure, x-rays are detected in a non dispersive Si(Li) solid state detector. Absolute determinations are made by comparison with standard solutions. Detection limits in a 5 minutes run are in the ppm range for a single drop (0.05 ml). The application of this technique to the determination of trace elements in biological liquids is investigated (Cr, Mn, Fe, Co, Ni, Cu, Zn, in plant extracts, haemocyanine, albumins...). (author)

  6. Validation of multi-element isotope dilution ICPMS for the analysis of basalts

    Energy Technology Data Exchange (ETDEWEB)

    Willbold, M.; Jochum, K.P.; Raczek, I.; Amini, M.A.; Stoll, B.; Hofmann, A.W. [Max-Planck-Institut fuer Chemie, Mainz (Germany)

    2003-09-01

    In this study we have validated a newly developed multi-element isotope dilution (ID) ICPMS method for the simultaneous analysis of up to 12 trace elements in geological samples. By evaluating the analytical uncertainty of individual components using certified reference materials we have quantified the overall analytical uncertainty of the multi-element ID ICPMS method at 1-2%. Individual components include sampling/weighing, purity of reagents, purity of spike solutions, calibration of spikes, determination of isotopic ratios, instrumental sources of error, correction of mass discrimination effect, values of constants, and operator bias. We have used the ID-determined trace elements for internal standardization to improve indirectly the analysis of 14 other (mainly mono-isotopic trace elements) by external calibration. The overall analytical uncertainty for those data is about 2-3%. In addition, we have analyzed USGS and MPI-DING geological reference materials (BHVO-1, BHVO-2, KL2-G, ML3B-G) to quantify the overall bias of the measurement procedure. Trace element analysis of geological reference materials yielded results that agree mostly within about 2-3% relative to the reference values. Since these results match the conclusions obtained by the investigation of the overall analytical uncertainty, we take this as a measure for the validity of multi-element ID ICPMS. (orig.)

  7. The Impact of Fluid Inertia on In Vivo Estimation of Mitral Valve Leaflet Constitutive Properties and Mechanics.

    Science.gov (United States)

    Bark, David L; Dasi, Lakshmi P

    2016-05-01

    We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstruction of markers from stereo images. To investigate the effect in vivo, the analysis is repeated on a published dataset for an ovine mitral valve (Journal of Biomechanics 42(16): 2697-2701). The membrane experiment demonstrates that the relationship between pressure and strain must be corrected with a fluid inertia term if the ratio of inertia to pressure differential approaches 1. In the mitral valve, this ratio reaches 0.7 during isovolumetric contraction for an acceleration of 6 m/s(2). Acceleration is reduced by 72% during isovolumetric relaxation. Fluid acceleration also varies along the leaflet during isovolumetric phases, resulting in spatial variations in stress. These results demonstrate that fluid inertia may be the source of the temporally and spatially varying stiffness measurements previously seen through inverse finite element analysis of in vivo data during isovolumetric phases. This study demonstrates that there is a need to account for added mass effects when analyzing in vivo constitutive relationships of heart valves.

  8. Determination of trace elements in fisheries samples by instrumental neutron and photon activation analysis

    International Nuclear Information System (INIS)

    Chattopadhyay, A.; Ellis, K.M.; Nimalasiri Desilva, K.

    1979-01-01

    An instrumental neutron activation analysis (INAA) method has been developed for the simultaneous determination of trace concentrations of up to 23 elements in fisheries samples. The INAA method consists of irradiations of wet and lyophilized cod muscle and liver samples for three different periods at a flux density of 5x10 11 n.cm -2 .s -1 and subsequent measurements after four different decay periods using high-resolution Ge(Li) gamma-ray spectrometry. Concentrations of several essential and toxic elements have been determined. Loss of certain elements during lyophilization has been studied. Elemental distribution in muscles and livers as a function of the age of fish has been investigated. Precision and accuracy of the INAA method have been evaluated by analysing replicate samples, National Bureau of Standards' bovine liver standard reference material, and an intercalibration fish flour sample provided by the International Council for the Exploration of the Sea. A few fish samples have also been analysed by an alternative method, namely instrumental photon activation analysis (IPAA). Elemental concentrations determined by both INAA and IPAA methods are reported here. (author)

  9. Development and use of in vivo neutron activation analysis at Leeds

    International Nuclear Information System (INIS)

    Burkinshaw, L.; Oxby, C.B.; Ellis, R.E.

    1986-01-01

    We have devised a technique for measuring the total amounts of the elements K, N, Na, Cl, P and Ca in the living human body by neutron activation analysis. We have used it to study changes in body composition associated with disease and are now extending it to measure total body C, H and O also. (author)

  10. Analysis of pipe mitred bends using beam models - by finite element method

    International Nuclear Information System (INIS)

    Salles, A.C.S.L. de.

    1984-01-01

    The formulation of a recently proposed displacement based straight pipe element for the analysis of pipe mitred bends is summarized in this work. The element kinematics includes axial, bending, torsional and ovalisation displacements, all varying cubically along the axis of the element. Interaction effects between angle adjoined straight pipe section are modeled including the appropriate additional strain terms in the stiffness matrix formulation and by using a penalty procedure to enforce continuity of pipe skin flexural rotations at the common helical edge. The element model capabilities are ilustrated in some sample analysis and the results are compared with other available experimental, analytical or more complex numerical models. (Author) [pt

  11. Investigation of trace elements in Elbe water by means of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Motamedi, K.

    1977-01-01

    Investigations of trace elements in Elbe water were carried out as a contribution to environmental research, hydrology, and geochemistry. The method applied - instrumental neutron activation analysis - is described, and problems connected with the course of analysis - sample taking, handling and preparation as well as optimization of in-pile irradiation and measurement by means of γ spectrometry - are discussed and presented one by one. The computer programme set up for automatic evaluation is described in more detail. This programme AKAN has a very general concept which makes it applicable for general use. The reliability of the evaluation procedure - monostandard method - and the reproducibility of the results are discussed. For the studies, samples were taken at different times, every time from 8 positions along a long section of the Elbe. The content of solids was analyzed; in a number of samples, this was done by separating suspended and dissolved materials. Up to 38 elements were analyzed, whose local and time-dependent concentration curves are given. The contents of some elements are compared with the few available data from literature. Correlation calculations indicate a similar behaviour of single element groups and yield information on the natural origin of the trace elements and on anthropogenic influence to be noticed in the trace element contents. (orig.) [de

  12. Analysis of trace elements in chicken embryo cells

    International Nuclear Information System (INIS)

    Qiu Zhijun; Wang Jiqing; Guo Panlin; Li Xiaolin; Zhu Jieqing; Lu Rongrong

    2002-01-01

    A scanning proton microprobe (SPM) with high resolution and high sensitivity was applied to analyze trace elements in chicken embryo forebrain neutron cell and skeletal muscle myotube cell. The absorption of the two different cells to zinc ions, correlation of elements and trace elemental distributions in the cells were studied. The results indicate that the absorptive capacity of the chicken embryo forebrain neuron cell to zinc ions is larger than that of the chicken embryo skeletal muscle myotube cell, and the concentrations of intracellular trace elements such as Cr, Fe, Ni are explicitly higher. The correlations of elements such as S and Zn or Fe and Zn are positive, but the correlations of P and Ni or Cr and Fe are negative. From the maps of cellular elemental distribution the contents of the different elements are different in the intracellular parts, for example, the contents of the elements phosphorus, sulfur, potassium in the cell membranes are higher than that in the cells

  13. Finite element analysis of adanced composite structures containing mechanically fastened joints

    International Nuclear Information System (INIS)

    Baumann, E.

    1982-01-01

    Although the usual engineering practice is to ignore joint effects in finite element models of overall structures, there are times when the inclusion of fastener effects in a model is necessary for accurate analysis. This paper describes some simple but accurate methods for accommodating this modeling requirement. The approach involves correlation of test results from a few composite mechanically fastened joints with finite element analyses of joints. It is assumed that if the fastener actions in the test articles can be properly predicted by simple finite element techniques, then these same techniques can be applied to large overall structure models. During the course of this test-analysis effort it was determined that it is possible to obtain correct results for overall structure-joint analyses by using simple modeling concepts provided special care is employed. Also, some emphasis is given in this paper to the importance of properly reducing test data in order to obtain meaningful correlations with finite element analysis. Finally, for those interested, the appendix contains brief descriptions of the test results and failure modes explored in the test program. (orig.)

  14. The role of neutron activation analysis for trace elements characterization, analysis and certification in atmospheric particulates

    International Nuclear Information System (INIS)

    Rizzio, Enrico; Gallorini, Mario

    2002-01-01

    The Neutron Activation Analysis (NAA) owns these requirements and is universally accepted as one of the most reliable analytical tools for trace and ultratrace elements determination. Its use in trace elements atmospheric pollution related studies has been and is still extensive as can be demonstrate by several specific works and detailed reviews. In this work, the application of this nuclear technique, in solving a series of different analytical problems related to trace elements in air pollution processes is reported. Examples and results are given on the following topics: characterization of urban and rural airborne particulate samples; particles size distribution in the different inhalable and respirable fractions (PM10 and PM 2.5); certification of related Standard Reference Materials for data quality assurance. (author)

  15. The state-of-the-art and problems of fuel element structural analysis

    International Nuclear Information System (INIS)

    Lassmann, K.

    1980-02-01

    This study of fuel element structural analysis is arranged in two parts: In the first, self-contained, part the general basic principles of deterministic computer programs for structural analysis of fuel elements are reviewed critically and an approach is shown which can be used to expand the system with respect to statistical investigations. The second part contains technical details summarized in 11 publications, all of which appeared in periodicals with reviewer teams. The major aspects of this study are thought to be the following ones: Contributions to the 'philosophy' of fuel element structural analysis. Critical analysis of the basic structure of computer programs. Critical analysis of the mechanical concept of integral fuel rod computer programs. Establishment of a comprehensive computer program system (URANUS). Expansion from purely deterministic information by statistical analyses. Methodological and computer program developments for the analysis of fast accidents. (orig.) 891 HP/orig. 892 MKO [de

  16. Optimization of data analysis for the in vivo neutron activation analysis of aluminum in bone

    International Nuclear Information System (INIS)

    Mohseni, H.K.; Matysiak, W.; Chettle, D.R.; Byun, S.H.; Priest, N.; Atanackovic, J.; Prestwich, W.V.

    2016-01-01

    An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5 μg Al/g Ca) compared to the inverse-variance weighted mean (5.2 μg Al/g Ca), rendering both equally applicable to human measurements. - Highlights: • Data analysis optimization for measuring aluminum in human subjects. • Development and Comparison of multiple approaches to data analysis for NAA of Al. • Improving the MDL of IVNAA method for Al measurement compared to previous studies. • Exploring the advantage of sequential data acquisition for IVNAA data analysis.

  17. Neutron activation analysis applied to the determination of trace elements in human nails

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo

    2001-01-01

    There is a considerable interest in the determination of trace elements in human nails in order to use this tissue as a monitor of nutritional and healthy status of individuals, of occupational exposure diseases and of the environmental contamination. In this work, instrumental neutron activation analysis was applied to determine trace elements in finger nail clippings to make comparisons between the elemental concentrations obtained in nails from healthy individuals of a control group and those from cystic fibrosis (CF) patients. Firstly, a protocol for sample collection and preparation for analysis was established. Finger and toe nail samples from CF patients were collected at the Instituto da Crianca of Medicine School, University of Sao Paulo, SP. The nail samples from control group were collected from healthy adults and from children living in Sao Paulo city, SP. These samples were cleaned by stirring them witha a diluted Triton X100 solution and then by washing with distilled water and acetone. The analytical procedure consisted of irradiation nail samples and elemental standards in the IEA-R1m nuclear reactor under thermal neutro flux of about 10 12 n cm -2 s -1 , for short and long period irradiations. The activities of the radionuclides were measured using a gamma-ray spectrometer comprising an hyperpure Ge detector and associated electronic system. The biological reference materials Bovine Liver 1577b and Oyster Tissue 1566a, both from National Institute of Standards and Technology, USA were analysed in order to evaluate the accuracy and precision of the results. The analysis of variance (ANOVA) and F-test at the significance level of 5% were used to make a comparison between the sets of results obtained in this work. In the comparison of the results obtained for finger and toe nails from CF patients, the Br concentrations were higher in finger nails that those obtained for toe nails. For the control group of children, the finger nails presented different

  18. Characteristic and analysis of structural elements of corporate social responsibility

    Directory of Open Access Journals (Sweden)

    J. S. Bilonog

    2015-04-01

    Full Text Available In this article attention is focused on social responsibility of business and on necessity to estimate its condition in Ukraine. Materials regarding elements and the principles of corporate social responsibility are structured. On this basis unification of quantitative elements of business social responsibility is offered according to which it is possible to carry out the analysis of the non­financial reporting. It is proposed to use not only quantitative techniques of data analysis but also refer to the qualitative ones. As a result of this, the analysis of social reports will be more productive and would minimize subjectivity of the researcher or representatives of the company which are responsible for presenting the information to the general public. The basic principles by which the companies can realize the strategy of corporate social responsibility are considered. Due to the empirical analysis of corporate reports expediency to use specified elements is proved. Reports of the companies in producing and non­productive sector are analyzed in more detail; features of displaying information on corporate social responsibility are defined. The attention to need of carrying out monitoring researches in the sphere of the corporate social reporting is updated.

  19. Finite element analysis of rotating beams physics based interpolation

    CERN Document Server

    Ganguli, Ranjan

    2017-01-01

    This book addresses the solution of rotating beam free-vibration problems using the finite element method. It provides an introduction to the governing equation of a rotating beam, before outlining the solution procedures using Rayleigh-Ritz, Galerkin and finite element methods. The possibility of improving the convergence of finite element methods through a judicious selection of interpolation functions, which are closer to the problem physics, is also addressed. The book offers a valuable guide for students and researchers working on rotating beam problems – important engineering structures used in helicopter rotors, wind turbines, gas turbines, steam turbines and propellers – and their applications. It can also be used as a textbook for specialized graduate and professional courses on advanced applications of finite element analysis.

  20. Detection of secondary structure elements in proteins by hydrophobic cluster analysis.

    Science.gov (United States)

    Woodcock, S; Mornon, J P; Henrissat, B

    1992-10-01

    Hydrophobic cluster analysis (HCA) is a protein sequence comparison method based on alpha-helical representations of the sequences where the size, shape and orientation of the clusters of hydrophobic residues are primarily compared. The effectiveness of HCA has been suggested to originate from its potential ability to focus on the residues forming the hydrophobic core of globular proteins. We have addressed the robustness of the bidimensional representation used for HCA in its ability to detect the regular secondary structure elements of proteins. Various parameters have been studied such as those governing cluster size and limits, the hydrophobic residues constituting the clusters as well as the potential shift of the cluster positions with respect to the position of the regular secondary structure elements. The following results have been found to support the alpha-helical bidimensional representation used in HCA: (i) there is a positive correlation (clearly above background noise) between the hydrophobic clusters and the regular secondary structure elements in proteins; (ii) the hydrophobic clusters are centred on the regular secondary structure elements; (iii) the pitch of the helical representation which gives the best correspondence is that of an alpha-helix. The correspondence between hydrophobic clusters and regular secondary structure elements suggests a way to implement variable gap penalties during the automatic alignment of protein sequences.

  1. Elemental composition of platelets. Part I. Sampling and sample preparation of platelets for trace-element analysis

    International Nuclear Information System (INIS)

    Iyengar, G.V.; Borberg, H.; Kasperek, K.; Kiem, J.; Siegers, M.; Feinendegen, L.E.; Gross, R.

    1979-01-01

    Sampling of platelets for trace-element analysis poses special problems: obtaining adequate sample materials, achieving a sufficient cell purity, preserving viability (integrity), correcting for trapped plasma, and controlling contamination. We used a blood-cell separator for the primary isolation of platelets from blood, and differential centrifugation in natural plasma to further isolate them. The pyrimidopyrimidine RA233 was used as a stabilizer to maintain viability. 131 I-labeled human serum albumin was used to estimate trapped plasma. Contamination was controlled by using five-times-distilled water to simulate donor's blood in the system and by comparing three fractions: the serum, the first portion of the platelet-rich plasma, and the supernatant plasma after the final centrifugation. Neutron activation analysis was used for the elemental analysis. A single differential centrifugation of the platelet-rich plasma from the blood-cell separator at 400 x g for 8 min was optimum (mean mass fractions: erythrocytes/platelets < 5 mg/g and leukocytes/platelets < 20 mg/g). The trapped plasma in the wet platelet samples amounted to about 0.40 g/g. No appreciable contamination from the sampling system was found for the elements Ag, Cd, Co, Cr, Cs, Cu, Fe, Mo, Rb, Sb, Se, and Zn. 2 figures, 3 tables

  2. FINITE ELEMENT ANALYSIS OF HASTELLOY C-22HS IN END MILLING

    Directory of Open Access Journals (Sweden)

    K. Kadirgama

    2011-12-01

    Full Text Available This paper presents a finite element analysis of the stress distribution in the end milling operation of nickel-based superalloy HASTELLOY C-2000. Commercially available finite element software was used to develop the model and analyze the distribution of stress components in the machined surface of HASTELLOY C-22HS following end milling with coated carbide tools. The friction interaction along the tool-chip interface was modeled using the Coulomb friction law. It was found that the stress had lower values under the cut surface and that it increased gradually near the cutting edge.

  3. Prompt gamma-ray spectroscopy and its use for the elemental chemical analysis

    International Nuclear Information System (INIS)

    Deconninck, G.; Demortier, G.; Bodart, F.

    The elemental chemical analysis by nuclear techniques has been widely developed since a quarter of century. In this review the analysis by irradiation of the the sample (solid or liquid) of a majority of chemical elements by means of the charged particles and the detection during this irradiation of the gamma photons characteristic of the element are considered. After a brief account of the physical phenomena peculiar to the prompt detection of photons in comparison with the activation methods where a delayed activity is measured, a brief description of the experimental equipment for this kind of analysis is given. A comprehensive critical survey of the recent applications to the analysis of metals, semiconductors and electric insulating substances is presented. The necessary informations for the choice of the nuclear reaction to use for a specific analysis are contained in a set of tables. (AF)

  4. Application of PIXE analysis to environmental samples stable element distribution in sea algae by scanning microprobe analysis

    International Nuclear Information System (INIS)

    Ishikawa, M.; Kitao, K.; Imaseki, H.; Ishii, T.; Uchida, S.

    1984-01-01

    The resolution of a 33+-3 μm microprobe focussed with quadrupole doublet installed at the 3 MV Van de Graaff of the National Institute of Radiological Sciences, Japan, was used for the present analysis. Brown algae, Hizikia fusiforme was the sample target bombarded with a 2 MeV proton beam collimated mechanically into a rectangular image of 100 μm x 700 μm. Scanning across the sample target prepared into a longitudinal section from the caulis of the algae provided the following observations. More than 12 elements such as Al, Si, P, Cl, Ca, Mn, Fe, Cu, Zn, As, Br and Sr were determined simultaneously, together with their distributional information across the diameter. In the medullary layer, Mn and Zn were specific in their accumulation, while the deposition of Fe, Cu, As and Br were observed to be high in the epithelial layer, especially Fe and Cu which were found on the surface, where they contacted ambient sea water, but no significant change in pattern was indicated for such elements as Al, P and Cl. The PIXE microprobe analysis was, therefore, effective in its detectability for elements below a few ppm level, resultantly providing further possibilities for collecting information from bio-medical and environmental samples on trace characterization of elements. (author)

  5. Co-localized or randomly distributed? Pair cross correlation of in vivo grown subgingival biofilm bacteria quantified by digital image analysis.

    Directory of Open Access Journals (Sweden)

    Claudia Schillinger

    Full Text Available The polymicrobial nature of periodontal diseases is reflected by the diversity of phylotypes detected in subgingival plaque and the finding that consortia of suspected pathogens rather than single species are associated with disease development. A number of these microorganisms have been demonstrated in vitro to interact and enhance biofilm integration, survival or even pathogenic features. To examine the in vivo relevance of these proposed interactions, we extended the spatial arrangement analysis tool of the software daime (digital image analysis in microbial ecology. This modification enabled the quantitative analysis of microbial co-localization in images of subgingival biofilm species, where the biomass was confined to fractions of the whole-image area, a situation common for medical samples. Selected representatives of the disease-associated red and orange complexes that were previously suggested to interact with each other in vitro (Tannerella forsythia with Fusobacterium nucleatum and Porphyromonas gingivalis with Prevotella intermedia were chosen for analysis and labeled with specific fluorescent probes via fluorescence in situ hybridization. Pair cross-correlation analysis of in vivo grown biofilms revealed tight clustering of F. nucleatum/periodonticum and T. forsythia at short distances (up to 6 µm with a pronounced peak at 1.5 µm. While these results confirmed previous in vitro observations for F. nucleatum and T. forsythia, random spatial distribution was detected between P. gingivalis and P. intermedia in the in vivo samples. In conclusion, we successfully employed spatial arrangement analysis on the single cell level in clinically relevant medical samples and demonstrated the utility of this approach for the in vivo validation of in vitro observations by analyzing statistically relevant numbers of different patients. More importantly, the culture-independent nature of this approach enables similar quantitative analyses for "as

  6. Uniform elemental analysis of materials by sputtering and photoionization mass spectrometry

    International Nuclear Information System (INIS)

    Chun, He; Basler, J.N.; Becker, C.H.

    1997-01-01

    Analysis of the elemental composition of surfaces commonly involves techniques in which atoms or ions are ablated from the material's surface and detected by mass spectrometry. Secondary-ion mass spectrometry is widely used for detection with high sensitivity (down to a few parts per billion) but technical problems prevent it from being truly quantitative. Some of these problems are circumvented by nonresonant laser post-ionization of sputtered atoms followed by time-of-flight mass spectrometry (surface analysis by laser ionization: SALI). But when there are large differences in ionization probabilities amongst different elements in the material, the detection sensitivity can be non-uniform and accurate quantification remains out of reach. Here we report that highly uniform, quantitative and sensitive analysis of materials can be achieved using a high-energy (5-keV) ion beam for sputtering coupled with a very-high-intensity laser to induce multiphoton ionization of the sputtered atoms. We show uniform elemental sensitivity for several samples containing elements with very different ionization potentials, suggesting that this approach can now be regarded as quantitative for essentially any material. (author)

  7. Overview of adaptive finite element analysis in computational geodynamics

    Science.gov (United States)

    May, D. A.; Schellart, W. P.; Moresi, L.

    2013-10-01

    The use of numerical models to develop insight and intuition into the dynamics of the Earth over geological time scales is a firmly established practice in the geodynamics community. As our depth of understanding grows, and hand-in-hand with improvements in analytical techniques and higher resolution remote sensing of the physical structure and state of the Earth, there is a continual need to develop more efficient, accurate and reliable numerical techniques. This is necessary to ensure that we can meet the challenge of generating robust conclusions, interpretations and predictions from improved observations. In adaptive numerical methods, the desire is generally to maximise the quality of the numerical solution for a given amount of computational effort. Neither of these terms has a unique, universal definition, but typically there is a trade off between the number of unknowns we can calculate to obtain a more accurate representation of the Earth, and the resources (time and computational memory) required to compute them. In the engineering community, this topic has been extensively examined using the adaptive finite element (AFE) method. Recently, the applicability of this technique to geodynamic processes has started to be explored. In this review we report on the current status and usage of spatially adaptive finite element analysis in the field of geodynamics. The objective of this review is to provide a brief introduction to the area of spatially adaptive finite analysis, including a summary of different techniques to define spatial adaptation and of different approaches to guide the adaptive process in order to control the discretisation error inherent within the numerical solution. An overview of the current state of the art in adaptive modelling in geodynamics is provided, together with a discussion pertaining to the issues related to using adaptive analysis techniques and perspectives for future research in this area. Additionally, we also provide a

  8. Use of multivariate and neutron activation analysis on studying element interrelationships in Brazilian phosphorite

    International Nuclear Information System (INIS)

    Delgado, J.U.; Carvalho, J.L.S.; Tauhata, L.

    1993-01-01

    Methods to determine U, Th and other constituent elements in mineral matrices through Instrumental Neutron Activation Analysis (INAA), have been widely utilized due to their capability to extract a large quantity of information from small samples. In the present work, an experimental methodology based on INAA associated to the cluster statistics technique was used to determine the uranium concentration and its correlation with other elements present in the mineral phosphorites from the northeast region of Brazil. Data for 22 elements including rare-earth elements are presented. A good correlation between uranium and rare-earth elements is observed. For the transition metals, correlation with uranium was not noted. (author) 11 refs.; 2 figs.; 1 tab

  9. Analysis of Trace Elements in South African Clinkers using Latent ...

    African Journals Online (AJOL)

    The trace element content of clinkers (and possibly of cements) can be used to identify the manufacturing factory. The Mg, Sr, Ba, Mn, Ti, Zr, Zn and V content of clinkers give detailed information for the determination of the origin of clinkers produced in different factories. However, for the analysis of such complex data there ...

  10. Nondestructive elemental analysis of coins using accelerator-based thermal neutrons

    International Nuclear Information System (INIS)

    Khairi, F.Z.; Aksoy, A.; Al-Haddad, M.N.

    2007-01-01

    The accelerator-based thermal-neutrons activation analysis setup at KFUPM has an adequate thermal -neutron flux that can be advantageously used for the elemental analysis of a variety of samples including archeological ones. The thermal neutrons are derived from the moderation of fast neutrons from the D (d, n) He reaction which produces fast 2.5 MeV neutrons. A maximum thermals flux of about 2.5x10 n/m-s was achieved. For the purpose of determining the suitability of the set up for the analysis of contemporary and ancient coins, we carried out a feasibility study by irradiating a selected number of Saudi Arabian coins dating from 1958 to 1987 in the thermal-neutron flux. The induced gamma-ray activities were then counted using a HP-GMX detector coupled to a PC-based data acquisition and analysis system. The elements that were determined in the coins were copper (75%), nickel (around 25%) and manganese (<0.5%). Calibration curves were also established for these elements. The determined concentrations are in agreement with the data published by the Standard Catalogue of World Coins. (author)

  11. Elemental analysis of sub-hourly ambient aerosol collections

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, C.B.; Ondov, J.M. [University of Maryland, College Park, MD (USA). Dept. of Chemical & Biochemistry

    2004-03-01

    Simultaneous multielement graphite furnace atomic absorption spectrometry was used to determine Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Se, and Zn in ambient air sampled at 170 L.min{sup -1} for 30 min and collected as a slurry after dynamic preconcentration. Analyses of slurries of NIST SRM 1648, Urban Particulate Matter, were typically within 10% of expected values for all elements except Al, Cr, and Fe, elements for which deviations were mostly due to difficulties in transferring large particles. This problem will be reduced for urban fine particulate matter samples (PM2.5). Trends in the concentrations of elemental source markers were readily correlated with wind direction and other meteorological factors to identify the influences of local industrial emissions, including motor vehicle traffic, coal- and oil-fired power plants, and municipal incinerators. Factor analysis was applied to the 88-sample data set to extract 7 factors: urban dust, meteorological factors, incinerators, coal- fired power plants, Tour Bus emission, unknown As source, and oil-fired power plants. Factor analysis was also applied to an 18-sample data set representing 2.5 h averages of the 30 min data to simulate the effect of longer sample collection times. Only 6 factors were extracted from this data set, which shows that increased temporal resolution enhances the power of factor analysis to resolve sources. These results indicate that a wealth of detailed information is revealed at this level of temporal resolution.

  12. Energy Finite Element Analysis Developments for Vibration Analysis of Composite Aircraft Structures

    Science.gov (United States)

    Vlahopoulos, Nickolas; Schiller, Noah H.

    2011-01-01

    The Energy Finite Element Analysis (EFEA) has been utilized successfully for modeling complex structural-acoustic systems with isotropic structural material properties. In this paper, a formulation for modeling structures made out of composite materials is presented. An approach based on spectral finite element analysis is utilized first for developing the equivalent material properties for the composite material. These equivalent properties are employed in the EFEA governing differential equations for representing the composite materials and deriving the element level matrices. The power transmission characteristics at connections between members made out of non-isotropic composite material are considered for deriving suitable power transmission coefficients at junctions of interconnected members. These coefficients are utilized for computing the joint matrix that is needed to assemble the global system of EFEA equations. The global system of EFEA equations is solved numerically and the vibration levels within the entire system can be computed. The new EFEA formulation for modeling composite laminate structures is validated through comparison to test data collected from a representative composite aircraft fuselage that is made out of a composite outer shell and composite frames and stiffeners. NASA Langley constructed the composite cylinder and conducted the test measurements utilized in this work.

  13. Trace elements in several species of crustaceans of Amami Island Group in Japan determined by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2001-01-01

    Concentration levels of trace elements were determined in several species of subtropical crustaceans from Amami Islands in Japan in order to evaluate the levels of specific accumulation of elements among species. Tissue samples prepared from gill, muscle, hepatopancreas, and testis were irradiated for photon activation analysis (PAA) and neutron activation analysis (NAA). By PAA and NAA, eighteen elements could be determined. The levels of Br and I were extremely high in gills of spiny lobster and shovel-nosed lobster, respectively. A high concentration of Ag was found in the hepatopancreas of spiny lobsters collected from the Amami Island, while this element was not detected in the same species collected from Toba. The results suggest that the distribution of the trace elements in different tissues and species varies according to both species and environmental differences. To study the molecular forms of the elements in tissue, fractions that contained protein-bound elements from the hepatopancreas of spiny lobsters were separated by ultracentrifugation and gel filtration chromatography. Elution profiles of the chromatography suggest that Cu, Fe, and Se were bound to proteins, while Ag was not. (author)

  14. Finite elements for non-linear analysis of pipelines

    International Nuclear Information System (INIS)

    Benjamim, A.C.; Ebecken, N.F.F.

    1982-01-01

    The application of a three-dimensional lagrangian formulation for the great dislocations analysis and great rotation of pipelines systems is studied. This formulation is derived from the soil mechanics and take into account the shear stress effects. Two finite element models are implemented. The first, of right axis, uses as interpolation functions the conventional gantry functions, defined in relation to mobile coordinates. The second, of curve axis and variable cross sections, is obtained from the degeneration of the three-dimensional isoparametric element, and uses as interpolation functions third degree polynomials. (E.G.) [pt

  15. Fourier analysis of finite element preconditioned collocation schemes

    Science.gov (United States)

    Deville, Michel O.; Mund, Ernest H.

    1990-01-01

    The spectrum of the iteration operator of some finite element preconditioned Fourier collocation schemes is investigated. The first part of the paper analyses one-dimensional elliptic and hyperbolic model problems and the advection-diffusion equation. Analytical expressions of the eigenvalues are obtained with use of symbolic computation. The second part of the paper considers the set of one-dimensional differential equations resulting from Fourier analysis (in the tranverse direction) of the 2-D Stokes problem. All results agree with previous conclusions on the numerical efficiency of finite element preconditioning schemes.

  16. The fingerprint element analysis on provenance of ancient chinese Jun porcelain

    International Nuclear Information System (INIS)

    Gao Zhengyao; Chen Songhua; Wang Jie; Huang Zhongxiang; Jia Xiuqin; Han Song

    1997-01-01

    Forty-three samples of ancient Jun porcelains and so on were chosen. Neutron activation analysis (NAA) was used to measure the 36 trace elements in every sample. Seven elements were chosen as the 'fingerprint elements'. The provenance of the glazes and bodies of ancient Chinese Jun porcelain were investigated by the fingerprint element analysis method. The result shows that although the ancient Chinese Jun porcelain samples have been leapt over six hundred years, and glaze colors are utterly different and are from many different kilns, there are long term, stable and same mainly raw material source. The near provenance relation between ancient Jun porcelain and ancient Ru porcelain is preliminarily analyzed. A few modern Jun porcelains approximate from ancient Jun porcelains, the majority become estranged from ancient Jun porcelain

  17. Sensitivity analysis of the Galerkin finite element method neutron diffusion solver to the shape of the elements

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, Seyed Abolfaz [Dept. of Energy Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of)

    2017-02-15

    The purpose of the present study is the presentation of the appropriate element and shape function in the solution of the neutron diffusion equation in two-dimensional (2D) geometries. To this end, the multigroup neutron diffusion equation is solved using the Galerkin finite element method in both rectangular and hexagonal reactor cores. The spatial discretization of the equation is performed using unstructured triangular and quadrilateral finite elements. Calculations are performed using both linear and quadratic approximations of shape function in the Galerkin finite element method, based on which results are compared. Using the power iteration method, the neutron flux distributions with the corresponding eigenvalue are obtained. The results are then validated against the valid results for IAEA-2D and BIBLIS-2D benchmark problems. To investigate the dependency of the results to the type and number of the elements, and shape function order, a sensitivity analysis of the calculations to the mentioned parameters is performed. It is shown that the triangular elements and second order of the shape function in each element give the best results in comparison to the other states.

  18. Numerical simulation of in vivo intraosseous torsional failure of a hollow-screw oral implant

    Directory of Open Access Journals (Sweden)

    Akca Kivanc

    2006-11-01

    Full Text Available Abstract Background Owing to the complexity and magnitude of functional forces transferred to the bone-implant interface, the mechanical strength of the interface is of great importance. The purpose of this study was to determine the intraosseous torsional shear strength of an osseointegrated oral implant using 3-D finite element (FE stress analysis implemented by in vivo failure torque data of an implant. Methods A Ø 3.5 mm × 12 mm ITI® hollow screw dental implant in a patient was subjected to torque failure test using a custom-made strain-gauged manual torque wrench connected to a data acquisition system. The 3-D FE model of the implant and peri-implant circumstances was constructed. The in vivo strain data was converted to torque units (N.cm to involve in loading definition of FE analysis. Upon processing of the FE analysis, the shear stress of peri-implant bone was evaluated to assume torsional shear stress strength of the bone-implant interface. Results The in vivo torque failure test yielded 5952 μstrains at custom-made manual torque wrench level and conversion of the strain data resulted in 750 N.cm. FE revealed that highest shear stress value in the trabecular bone, 121 MPa, was located at the first intimate contact with implant. Trabecular bone in contact with external surface of hollow implant body participated shear stress distribution, but not the bone resting inside of the hollow. Conclusion The torsional strength of hollow-screw implants is basically provided by the marginal bone and the hollow part has negligible effect on interfacial shear strength.

  19. A quantitative analysis of statistical power identifies obesity end points for improved in vivo preclinical study design.

    Science.gov (United States)

    Selimkhanov, J; Thompson, W C; Guo, J; Hall, K D; Musante, C J

    2017-08-01

    The design of well-powered in vivo preclinical studies is a key element in building the knowledge of disease physiology for the purpose of identifying and effectively testing potential antiobesity drug targets. However, as a result of the complexity of the obese phenotype, there is limited understanding of the variability within and between study animals of macroscopic end points such as food intake and body composition. This, combined with limitations inherent in the measurement of certain end points, presents challenges to study design that can have significant consequences for an antiobesity program. Here, we analyze a large, longitudinal study of mouse food intake and body composition during diet perturbation to quantify the variability and interaction of the key metabolic end points. To demonstrate how conclusions can change as a function of study size, we show that a simulated preclinical study properly powered for one end point may lead to false conclusions based on secondary end points. We then propose the guidelines for end point selection and study size estimation under different conditions to facilitate proper power calculation for a more successful in vivo study design.

  20. The trace element analysis in freshwater fish species, water and sediment in Iyidere stream (Rize-Turkey).

    Science.gov (United States)

    Verep, Bulent; Mutlu, Cengiz; Apaydin, Gokhan; Cevik, Ugur

    2012-07-15

    Many environmental problems like dam construction, agricultural debris, flooding and industrial establishments threaten Iyidere stream (Rize, Turkey) on the southeastern coast of the Black Sea (Turkey). The trace element concentrations in water, fish and sediments in lyidere stream (Rize, Turkey) were investigated in this study. The concentration of six different elements in ten freshwater fish species and sediment was determined using energy dispersive X-ray fluorescence method. A radioisotope excited X-ray fluorescence analysis using the method of multiple standard addition is applied for the elemental analysis of fish and sediments. Water samples for trace metals were analyzed using standard spectrophotometry methods. A qualitative analysis of spectral peaks showed that ten different freshwater fish samples (Chondrostoma colchicum, Chalcalburnus chalcoides, Salmo trutta labrax, Alburnoides bipunctatus, Leuciscus cephalus, Barbus taurus escherichia, Capoeta tinca, Neogobius kessleri, Rutilus frisii, Lampetra lanceolata) and sediment contained phosphorus (P), sulphur (S), chlorine (Cl), potassium (K), calcium (Ca) and titanium (Ti). Heavy metals as toxic elements for biota (Pb, Cd, Hg, Zn and Mn etc.) were not detected in fish, water and sediments. Thus, It can be declared that freshwater fish of Iyidere does not contains health risks for consumers in terms of metal pollution.

  1. A study on chemical element determinations in human nails by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro; Saiki, Mitiko

    2013-01-01

    Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the Sao Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 10 12 n cm -2 s -1 at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO 3 solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in replicate. A

  2. A study on chemical element determinations in human nails by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro

    2012-01-01

    Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the Sao Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 10 12 n cm -2 s -1 at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO 3 solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in replicate. A

  3. A study on chemical element determinations in human nails by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Thalita Pinheiro; Saiki, Mitiko, E-mail: thalitapsanches@usp.br, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the Sao Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 10{sup 12} n cm{sup -2} s{sup -1} at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO{sub 3} solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in

  4. Sample preparation procedure for PIXE elemental analysis on soft tissues

    International Nuclear Information System (INIS)

    Kubica, B.; Kwiatek, W.M.; Dutkiewicz, E.M.; Lekka, M.

    1997-01-01

    Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed. The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples. (author)

  5. Determination of certain elements in camel's milk by neutron activation analysis

    International Nuclear Information System (INIS)

    Bejey, M.A.; Markus, W.M.; Etwir, R.H.

    1995-01-01

    Natural milk samples were analysed by instrumental neutron activation analysis (INAA) for (Mn, Fe, Zn, Co, Cr, Rb, Br, I). These samples were collected from different regions of libya co-operation with camel,s research center in tripoli. In our laboratories trace elements in human and milk powder samples have been, also determined using the (INAA) technique. The concentration level of the elements of interest of interest are in agreement to within 10% with obtained values for human and powder milk, except for the concentration of Br, I, and Rb which were found to be higher in camel's milk results of this investigation will be presented. 6 figs

  6. Determination of trace elements in lichen samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Horimoto, Lidia K.; Vasconcellos, Marina B.A.; Marcelli, Marcelo P.; Sumita, Nairo M.; Saldiva, Paulo H.N.

    2001-01-01

    Samples of Canoparmelia texana lichen collected in different sites of Sao Paulo and Parana States, Brazil, were analysed by neutron activation analysis in order to obtain preliminary information on the air quality in these regions and also to select a region of interest for biomonitoring studies. Also Tadescantia pallida plant has been analysed in order to study the viability of using this specimen in environmental pollution monitoring. Lichens samples were collected from tree barks which were also collected to investigate the contribution of substrate derived elements to elements present in lichens. Young and old leaves of T. pallida were collected separately in order to study the leaf age effects on their elemental levels. The samples were cleaned, washed with distilled water, dried and ground for the analyses. Samples and standards were irradiated at the IEA-Rlm nuclear reactor for short and long periods and concentrations of the elements Al, As, Ca, Cd, Cl, Co, Cr, Cs, Fe, Hf, Mg, Mn, Rb, Sb, Sc, D, Th, U, V Zn and lanthanides were determined. Preliminary results obtained for T. texana lichen indicated that three sites (Ibiuna, Botanical Garden and Parque de Vila Velha) present low concentrations of the most elements analysed. Therefore lichens from these regions could be analysed to establish baseline levels of elements for monitoring purposes. Samples collected in open areas presented high concentrations of some elements probably due to the accumulation of elements originating from soil and from heavy vehicular traffic. Elemental concentrations obtained in outer barks were similar or smaller than those results obtained for lichens. Results obtained for T. pallida indicated that concentrations of elements in old leaves of this plant are of the same magnitude or slightly higher than those presented in young ones. (author)

  7. Determination of elemental levels in radiopharmaceuticals by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, Gil; Guevara, Sergio Ribeiro; Arribere, Maria; Hernandez Rivero, Tulio

    2001-01-01

    Neutron Activation Analysis (NAA) both Instrumental (INAA) and Radiochemical (RNAA) have been extensively applied to the determination of minor and trace elements in samples of quite different origin and composition. Particularly, the analysis of microquantities of toxic elements in biological samples by INAA and RNAA is extensively reported. NAA has been also applied to the determination of minor and trace constituents in biomedical products. The use of the INAA in pharmaceutical samples has not been reported yet. This could be due in some extent because of the specificity of these types of samples, and also because of the need to irradiate the samples in a nuclear reactor. The objective of the present work was to study the feasibility of applying INAA for the quantification of minor and trace constituents in three radiopharmaceuticals. The formulation of these products was elaborated by the Isotope Center and proposed for registration to the corresponding authorities. The active components of three radiopharmaceuticals were analyzed: Hexamethylene propylene Amino oxine (HMPAO), Dimercaptosuccinic Acid (DMSA) and Diethylenetriamine penta-acetic Acid (DTPA). The samples were dried up to constant weight at room temperature. In order to avoid possible interferences from the irradiated polyethylene vials, the samples were pressed into the form of pills using a die of stainless steel. The weights of the samples ranged from 50 mg to 200 mg. Samples in duplicates were irradiated in the 0.5 k W Bariloche RA-6 Research Nuclear Reactor. To induce more (n,gamma) reactions and therefore increase the number of analytes and also to minimize interferences from activation products, the irradiation was carried out using two regimens. For the measurement, irradiated pills were put into clean polyethylene containers. The measurements were carried out with a 67 cm 3 ORTEC HPGe intrinsic-N coaxial detector with a resolution of 2.0 keV FWHM at 1.33 MeV and with an efficiency of 12

  8. Analysis of Piezoelectric Solids using Finite Element Method

    Science.gov (United States)

    Aslam, Mohammed; Nagarajan, Praveen; Remanan, Mini

    2018-03-01

    Piezoelectric materials are extensively used in smart structures as sensors and actuators. In this paper, static analysis of three piezoelectric solids is done using general-purpose finite element software, Abaqus. The simulation results from Abaqus are compared with the results obtained using numerical methods like Boundary Element Method (BEM) and meshless point collocation method (PCM). The BEM and PCM are cumbersome for complex shape and complicated boundary conditions. This paper shows that the software Abaqus can be used to solve the governing equations of piezoelectric solids in a much simpler and faster way than the BEM and PCM.

  9. Contribution to the analysis of light elements using x fluorescence excited by radio-elements

    International Nuclear Information System (INIS)

    Robert, A.

    1964-01-01

    In order to study the possibilities of using radioactive sources for the X-fluorescence analysis of light elements, the principle is given, after a brief description of X-fluorescence, of the excitation of this phenomenon by X, β and α emission from radio-elements. The operation and use of the proportional gas counter for X-ray detection is described. A device has been studied for analysing the elements of the 2. and 3. periods of the Mendeleev table. It makes it possible to excite the fluorescence with a radioactive source emitting X-rays or a particles; the X-ray fluorescence penetrates into a window-less proportional counter, this being made possible by the use of an auxiliary electric field in the neighbourhood of the sample. The gas detection pressure leading to the maximum detection yield is given. The spectra are given for the K α lines of 3. period elements excited by 55 Fe, 3 H/Zr and 210 Po sources; for the 2. period the K α spectra of carbon and of fluorine excited by the α particles of 210 Po. (author) [fr

  10. Analysis of some metallic elements and metalloids composition and relationships in parasol mushroom Macrolepiota procera.

    Science.gov (United States)

    Falandysz, Jerzy; Sapkota, Atindra; Dryżałowska, Anna; Mędyk, Małgorzata; Feng, Xinbin

    2017-06-01

    The aim of the study was to characterise the multi-elemental composition and associations between a group of 32 elements and 16 rare earth elements collected by mycelium from growing substrates and accumulated in fruiting bodies of Macrolepiota procera from 16 sites from the lowland areas of Poland. The elements were quantified by inductively coupled plasma quadrupole mass spectrometry using validated method. The correlation matrix obtained from a possible 48 × 16 data matrix has been used to examine if any association exits between 48 elements in mushrooms foraged from 16 sampling localizations by multivariate approach using principal component (PC) analysis. The model could explain up to 93% variability by eight factors for which an eigenvalue value was ≥1. Absolute values of the correlation coefficient were above 0.72 (significance at p < 0.05) for 43 elements. From a point of view by consumer, the absolute content of Cd, Hg, Pb in caps of M. procera collected from background (unpolluted) areas could be considered elevated while sporadic/occasional ingestion of this mushroom is considered safe. The multivariate functional analysis revealed on associated accumulation of many elements in this mushroom. M. procera seem to possess some features of a bio-indicative species for anthropogenic Pb but also for some geogenic metals.

  11. A positron emission tomography analysis of glucose metabolism in Alzheimer's disease brain using [18F] fluorodeoxyglucose. A parallel study with elemental concentrations

    International Nuclear Information System (INIS)

    Cutts, D.A.; Spyrou, N.M.; Stedman, J.D.

    2000-01-01

    Alzheimer's disease (AD) is a debilitating form of dementia which leads to impaired memory, thinking and behavior. Elemental concentrations between 'normal' and AD subjects as well as the hemispherical differences within the brain were examined. Tissue samples from both hemispheres of the frontal lobe in both AD and normal subjects were examined for their trace element concentrations using PIXE and RBS analyses. Elemental concentrations were seen to differ between AD and normal brain tissue samples. While in the normal group concentrations were found to be significantly higher in the right hemisphere than in the left the converse was tru in AD. A change in elemental concentrations may indicate possible alterations in the function of the blood brain barrier. This was examined by determining regional cerebral metabolic rates of glucose (rCMRGlu) using the in vivo technique of positron emission tomography (PET). Again variations between both hemispheres and between AD and normal were found. (author)

  12. OXYGEN PRESSURE REGULATOR DESIGN AND ANALYSIS THROUGH FINITE ELEMENT MODELING

    Directory of Open Access Journals (Sweden)

    Asterios KOSMARAS

    2017-05-01

    Full Text Available Oxygen production centers produce oxygen in high pressure that needs to be defused. A regulator is designed and analyzed in the current paper for medical use in oxygen production centers. This study aims to design a new oxygen pressure regulator and perform an analysis using Finite Element Modeling in order to evaluate its working principle. In the design procedure,the main elements and the operating principles of a pressure regulator are taking into account. The regulator is designed and simulations take place in order to assessthe proposed design. Stress analysis results are presented for the main body of the regulator, as well as, flow analysis to determine some important flow characteristics in the inlet and outlet of the regulator.

  13. Analysis of technology and quality control the fuel elements production process

    International Nuclear Information System (INIS)

    Katanic, J.; Spasic, Z.; Momcilovic, I.

    1976-01-01

    Recently great attention has been paid at the international level to the analysis of production processes and quality control of fuel elements with the aim to speed up activity of proposing and accepting standards and measurement methods. IAEA also devoted great interest to these problems appealing to more active participation of all users and procedures of fuel elements in a general effort to secure successful work with nuclear plants. For adequate and timely participation in future of the establishment and analysis of general requirements and documentation for the control of purchased or self produced fuel elements in our country, it is necessary to be well informed and to follow this activity at the international level

  14. Finite element analysis of ARPS structures

    International Nuclear Information System (INIS)

    Ruhkamp, J.D.; McDougal, J.R.; Kramer, D.P.

    1998-01-01

    Algor finite element software was used to determine the stresses and deflections in the metallic walls of Advanced Radioisotope Power Systems (ARPS) designs. The preliminary design review of these systems often neglects the structural integrity of the design which can effect fabrication and the end use of the design. Before finite element analysis (FEA) was run on the canister walls of the thermophotovoltaic (TPV) generator, hand calculations were used to approximate the stresses and deflections in a flat plate. These results compared favorably to the FEA results of a similar size flat plate. The AMTEC (Alkali Metal Thermal-to-Electric Conversion) cells were analyzed by FEA and the results compared to two cells that were mechanically tested. The mechanically tested cells buckled in the thin sections, one at the top and one in the lower section. The FEA predicted similar stress and shape results but the critical buckling load was found to be very shape dependent

  15. Trace elements in termites by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, T. E-mail: tsuyoshi@termite.kuwri.kyoto-u.ac.jp; Kagemori, N.; Kawai, S.; Sera, K.; Futatsugawa, S

    2002-04-01

    Trace elements in a Japanese subterranean xylophagous termite, Coptotermes formosanus Shiraki, were analyzed by the PIXE method. The total amount of the 14 predominant elements out of 27 detected in an intact termite was higher in a soldier termite (23 000 {mu}g/g) than in a worker termite (10 000 {mu}g/g). A block of wood (Pinus densiflora Sieb. et Zucc.) for termite feed had a much lower concentration (3600 {mu}g/g) compared with that in an intact termite. This probably relates the functional bio-condensation and/or bio-recycling of trace elements in C. formosanus. When a termite was separated into three anatomical parts, head, degutted body and gut, the worker gut contained the highest total amount of the 14 predominant measured elements (31 000 {mu}g/g). This might be correlated with the higher activity of food digestion and energy production in the worker gut. Moreover, the mandible of the soldier head, with an exoskeleton that is intensely hardened, showed a preferential distribution of Mn and Fe. These results suggest that the characteristic localization of elements will be closely related to the functional role of the individual anatomical part of C. formosanus.

  16. Trace element analysis in soy sauce. 2

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomita, Michio; Yoshida, Koji.

    1994-01-01

    Trace elements in four kinds of soybean and three kinds of salt have been measured by means of in-air PIXE. In soybeans, which were made in Japan, America, Canada and China, six kinds of trace elements were detected, such as Mn, Fe, Ni, Cu, Zn and Br. The concentration of these elements varied depending on the place they were made. American soybean showed characteristic feature compared with other soybeans. As to the bromine concentration, American soybean contains ten times as much as Japanese one. In salts Br and Sr were detected. (author)

  17. Application of neutron activation analysis to the monitoring of trace elements in Brazilian foodstuffs

    International Nuclear Information System (INIS)

    Vasconcellos, M.B.A.; Munita, C.J.S.; Maihara, V.A.; Abe, R.M.

    1988-01-01

    The work of the group of the Radiochemistry Division on food analysis started with milk powder and bread samples, since these foodstuffs are largely consumed by the population of Sao Paulo (Brazil). Both instrumental and radiochemical NAA techniques were employed, allowing the determination of the elements Na, Cl, Mn, Br, Fe, Zn, Rb, Sb, Se, Cr, Al, Mg, Cu and La. Nuclear techniques for toxic elements in foodstuffs, were applied more specifically to the analysis of rice, specially for Hg and Se. A radiochemical separation procedure was developed for the determination of these two elements, at the ppb level, based on distillation and precipitation. INAA was applied to determine As, Br, Na, K, Rb and Zn, as well. 3 tabs

  18. The distribution of selected inorganic elements in tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jenkins, R.W.; Grubbs, H.J.; Newman, R.H.; Bass, R.T.; Brenizer, J.S.; Jones, D.C.; Williamson, T.G.; Danehower, D.A.; Long, R.C.

    1986-01-01

    The use of instrumental neutron activation analysis (INAA) in determining selected elements in biological materials has been reported by numerous authors. Some of these have detailed the use of INAA to determine an elemental analysis in tobaccos of various geographical origins. This paper describes the first use of INAA to measure the distribution of selected inorganic elements within the tobacco leaf at a single plant stalk position for one tobacco curing routine. Three replicate plots of a common bright tobacco cultivar were grown under normal cultural conditions characteristic for the bright variety. The tobacco leaves were sampled at selected positions in the leaf. The bright tobacco was cured in a conventional flue-curing barn using standard practices. Immediately after collection, each individual sample was freeze-dried, crushed and sampled. The leaf midrib samples were prepared using a similar procedure. A subsample of about 100 mg was taken from each sample, sealed in a polyethyelene bag, irradiated in a thermal neutron flux of 2 x 10 17 n-m -2 -s -1 in a pneumatic rabbit system, and subsequently counted to obtain the reported data. A standard reference material was used as a comparator to yield relative elemental concentrations for Ca, Mg, Mn, Na, K, Cl, and Br. The data show that chlorine, potassium, sodium and calcium have definite concentration trends within the tobacco leaf. The data also show that some elements, e,g, Mn, were more uniformly distributed throughout the leaf. (author)

  19. Determination of elemental concentrations in environmental plant samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Datta, J.; Chowdhury, D.P.; Verma, R.; Reddy, A.V.R.

    2012-01-01

    The intake of leafy vegetables in daily diet is very important to meet our nutritional needs. Vegetables provide the essential elements which are necessary and recommended for human growth. However, due to rapid industrialization and urbanization our environment becomes polluted and this affects the normal growth of agricultural products and composition of environmental species. The elemental concentrations present in the environmental samples are good indicators to assess the toxicological levels due to pollution affects. In the present work we have analysed several vegetable plant samples by instrumental neutron activation analysis to determine the elemental concentrations at major, minor and trace levels. The leafy vegetables like spinach, red leafy vegetable, pui, gourd leaf, lettuce and katoua were chosen as these are extensively consumed by local people in eastern part of India. We have determined 15 elements in the above mentioned vegetable samples and some of these are essential elements and some are toxic elements. It was found that Na and K were present as major elements, Fe and Zn as minor elements and As, Ce, Cr, Co, La, Mo, Rb, Sc, Sm, Sr as trace elements. The concentration level of Cr was found to be higher than that of recommended value certified by WHO and National environment quality control for human consumption. The validation of our analytical results have been performed by the Z-score tests through the determination of concentrations of the elements of interest in certified reference materials. (author)

  20. Establishing a protocol for element determination in human nail clippings by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro; Saiki, Mitiko

    2011-01-01

    Human nail samples have been analyzed to evaluate occupational exposure, nutritional status and to diagnose certain diseases. However, sampling and washing protocols for nail analyses vary from study to study not allowing comparisons between studies. One of the difficulties in analyzing nail samples is to eliminate only surface contamination without removing elements of interest in this tissue. In the present study, a protocol was defined in order to obtain reliable results of element concentrations in human nail clippings. Nail clippings collected from all 10 fingers or toes were previously pre cleaned using an ethyl alcohol solution to eliminate microbes. Then, the clippings were cut in small pieces and submitted to different reagents for washing by shaking. Neutron activation analysis (NAA) was applied for nail samples analysis which consisted of irradiating aliquots of samples together with synthetic elemental standards in the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Comparisons made between the results obtained for nails submitted to different reagents for cleaning indicated that the procedure using acetone and Triton X100 solution is more effective than that of nitric acid solution. Analyses in triplicates of a nail sample indicated results with relative standard deviations lower than 15% for most of elements, showing the homogeneity of the prepared sample. Qualitative analyses of different nail polishes showed that the presence of elements determined in the present study is negligible in these products. Quality control of the analytical results indicated that the applied NAA procedure is adequate for human nail analysis. (author)

  1. In vitro and in vivo analysis of radiolabeled clindamycin hydrogel gel by radioscintigraphic techniques

    International Nuclear Information System (INIS)

    Kumar, N.; Datta, M.; Chopra, M.K.; Soni, N.L.; Mittal, G.; Singh, T.; Bhatnagar, A.; Bhawna

    2010-01-01

    Full text: Acne is one of the common dermatological problems caused by microorganism Acne vulgaris, therefore being used commonly in the treatment of acne. Clindamycin is the 7- deoxy, 7- chloro congener of the lincomycin, a macrolide antibiotic derived from Streptomyces lincolnensis. This study was performed for in-vitro and in-vivo estimation of radiolabeled clindamycin hydrogel using radioscintigraphic techniques for transdermal permeation. Clindamycin was supplied as a gift sample by Glenmark Research Laboratory (Mumbai, India) and other chemicals and reagents used were of analytical grade and were purchased from Merck Chemicals (India). Clindamycin was radiolabeled with 99m Tc-pertechnetate using stannous chloride as a reducing agent. Radiolabeled clindamycin was characterized for its stability at room temperature and in physiological conditions (serum). Clindamycin hydrogel was prepared by dispersion of radiolabeled clindamycin in carbopol 980 containing polaxomer as surfactant and methyl paraben as preservative solution. The prepared hydrogel was analysed for in vitro analysis via franz diffusion cell and in vivo studies were performed in balb-C mice for biodistribution and skin permeation and were analysed by radiometry. The results obtained showed labeling efficiency of clindamycin was more than 90%, and that was consistent and the radiolabeled drug was stable upto 24 hrs in serum. In vitro release studies showed an increased release rate till four hours and it's become plateaus after 4 hours. In vivo biodistribution studies were showed 99m Tc clindamycin hydrogel remains stable and follow predominantly hepatic excretion. Biodistribution pattern suggests late redistribution from a storage sight, probably, body fats

  2. Application of neutron activation analysis to the detrmination of toxic elements in Australian foodstuffs

    International Nuclear Information System (INIS)

    Fardy, J.J.; McOrist, G.D.; Farrar, Y.J.; Gorman, T.F.; Bowles, C.H.; Tan Mingguang

    1988-01-01

    Recent measurements in our laboratory have indicated that the average selenium content in the plasma of Australians is 0.09 mg L -1 which is significantly lower than that found in the inhabitants of most other Western countries with the exception of New Zealand. Research aimed at explaining these low levels had begun when an invitation was received from the IAEA to join a Coordinated Research Programme on Nuclear Techniques for Toxic Elements in Foodstuffs. The investigation was widened, therefore, to include other toxic elements, arsenic, mercury, zinc and antimony and the suite of trace elements determined by neutron activation analysis (NAA) techniques. To complete the survey of toxic elements, the lead and cadmium of the chosen foodstuffs are being analysed by anodic stripping voltammetry (ASV) and soon will be examined by inductively coupled plasma mass spectrometry (ICPMS). Drinking water from a number of locations were sampled in cleaned, screw-top polystyrene containers, frozen and stored in a freezer until ready for analysis. 7 refs, 4 figs, 4 tabs

  3. Electromagnetic analysis of locking device for SMART control element drive mechanism

    International Nuclear Information System (INIS)

    Heo, H.; Kim, J. I.; Kim, J. H.; Kim, Y. W.; Park, J. S.

    1998-01-01

    A numerical electromagnetic analysis was performed for the control rod locking device which is installed in the control element drive mechanism of integral reactor, SMART. A plunger model for the electromagnetic analysis of the locking device was developed and theoretical bases for the model were established. Design parameters related to plunger pushing force were identified, and the optimum design point was determined by analyzing the trend of the plunger pushing force with finite element method

  4. Transcriptional regulation of rod photoreceptor homeostasis revealed by in vivo NRL targetome analysis.

    Directory of Open Access Journals (Sweden)

    Hong Hao

    Full Text Available A stringent control of homeostasis is critical for functional maintenance and survival of neurons. In the mammalian retina, the basic motif leucine zipper transcription factor NRL determines rod versus cone photoreceptor cell fate and activates the expression of many rod-specific genes. Here, we report an integrated analysis of NRL-centered gene regulatory network by coupling chromatin immunoprecipitation followed by high-throughput sequencing (ChIP-Seq data from Illumina and ABI platforms with global expression profiling and in vivo knockdown studies. We identified approximately 300 direct NRL target genes. Of these, 22 NRL targets are associated with human retinal dystrophies, whereas 95 mapped to regions of as yet uncloned retinal disease loci. In silico analysis of NRL ChIP-Seq peak sequences revealed an enrichment of distinct sets of transcription factor binding sites. Specifically, we discovered that genes involved in photoreceptor function include binding sites for both NRL and homeodomain protein CRX. Evaluation of 26 ChIP-Seq regions validated their enhancer functions in reporter assays. In vivo knockdown of 16 NRL target genes resulted in death or abnormal morphology of rod photoreceptors, suggesting their importance in maintaining retinal function. We also identified histone demethylase Kdm5b as a novel secondary node in NRL transcriptional hierarchy. Exon array analysis of flow-sorted photoreceptors in which Kdm5b was knocked down by shRNA indicated its role in regulating rod-expressed genes. Our studies identify candidate genes for retinal dystrophies, define cis-regulatory module(s for photoreceptor-expressed genes and provide a framework for decoding transcriptional regulatory networks that dictate rod homeostasis.

  5. Application of neutron activation analysis to trace element determinations in lung samples

    International Nuclear Information System (INIS)

    Rocero, Sizue Ota

    1992-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from the Medicine College of the University of Sao Paulo, SP, Brazil. Adequate conditions for preparation and analysis of samples were previously established. The preparation of samples consisted of homogenization, lyophilization and sterilization in 60 Co source. The samples and standards were irradiated in the IEA-R1 reactor under thermal neutron flux of 3.7 x 10 11 n.cm -2 .s -1 for 30 min to determine Cl, K, Mn and Na and for 16 h under flux of 10 19 n.cm -2 .s -1 for the determination of Au, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Rb, Sb, Sc, Se, Th and Zn. The counting were carried out with a hiperpure (ge) detector connected to a 4096 channels analyzer and a microcomputer. the results obtained for lung sample analyses indicated a good reproducibility of the method for most of the elements determined with relative standard deviations lower than 10.5%. The accuracy of the method was evaluated by analyzing reference materials such as IAEA Animal Muscle H-4, NIST Bovine Liver 1577a, IUPAC Bowen's Kale and NIES Vehicle Exhaust Particulates. The results obtained from these analyzes agreed with the values of the literature for several elements with relative errors less than 20%. Less precise and accurate results were obtained for elements with concentrations at the Mup/Kg levels. Elemental concentrations obtained in the lung tissue analyses were within the range of reference values for normal subjects presented in the literature, except for the Cl concentrations for non smokers, Hf in both groups and Sb for the smokers. By comparing results obtained for lung samples from smokers and non smokers, the concentrations of Ce, Cr and Sb were higher in lungs from smokers and the others elements were

  6. A solution for the integration of finite element analysis in a ship design environment

    International Nuclear Information System (INIS)

    Finifter, D.; Wyniecki, P.; Castel, J. de

    1982-01-01

    The DEMAIN system for the pre- and post-processing of finite element analyses of ship structures is presented. It is shown that this new modelling concept, although being self-contained and specialized, has features which relate it to computer-aided design applications of a more general nature. Thus, compared to other finite element pre/post-processors, it allows a more natural occurrence of the structural analysis task in the design flow and can be considered a major step towards an integrated design and analysis system. (orig.)

  7. Elements of healthy death: a thematic analysis.

    Science.gov (United States)

    Estebsari, Fatemeh; Taghdisi, Mohammad Hossein; Mostafaei, Davood; Rahimi, Zahra

    2017-01-01

    Background: Death is a natural and frightening phenomenon, which is inevitable. Previous studies on death, which presented a negative and tedious image of this process, are now being revised and directed towards acceptable death and good death. One of the proposed terms about death and dying is "healthy death", which encourages dealing with death positively and leading a lively and happy life until the last moment. This study aimed to explain the views of Iranians about the elements of healthy death. Methods: This qualitative study was conducted for 12 months in two general hospitals in Tehran (capital of Iran), using the thematic analysis method. After conducting 23 in-depth interviews with 21 participants, transcription of content, and data immersion and analysis, themes, as the smallest meaningful units were extracted, encoded and classified. Results: One main category of healthy death with 10 subthemes, including dying at the right time, dying without hassle, dying without cost, dying without dependency and control, peaceful death, not having difficulty at dying, not dying alone and dying at home, inspired death, preplanned death, and presence of a clergyman or a priest, were extracted as the elements of healthy death from the perspective of the participants in this study. Conclusion: The study findings well explained the elements of healthy death. Paying attention to the conditions and factors causing healthy death by professionals and providing and facilitating quality services for patients in the end stage of life make it possible for patients to experience a healthy death.

  8. Determination of trace elements in seawater by neutron activation analysis and electrochemical separation

    International Nuclear Information System (INIS)

    Jorstad, K.; Salbu, B.

    1980-01-01

    The combination of neutron activation analysis and electrolysis at a constant, controlled potential has proved itself to be a useful multielement method for the determination of 28 elements in seawater. After freeze-drying and irradiation, the samples are dissolved and electrolyzed for 1 h. The radioactive species deposited on the mercury cathode allow determination of 14 elements (Ag, As, Au, Cd, Co, Cr, Fe, Ga, Hg, La, Mo, Sb, Se, Zn). Another 14 elements (Ba, Br, Ca, Ce, Cs, Eu, Na, Rb, Sc, Sm, Sr, Th, U, Yb) are quantitatively determined by measuring the activities in the residual solution. To obtain a reproducible electrolysis, radioactive tracers have been used to study the decrease of element concentrations in solution as a function of time of electrolysis, the influence of the initial element concentration on the rate constant k, the effect of cathode material and of the pH in the solution. 4 figures, 4 tables

  9. Potential of PIXE for the elemental analysis of calcium hydroxide used in dentistry

    International Nuclear Information System (INIS)

    Suciu, Ioana; Ionescu, Ecaterina; Bodnar, Dan; Preoteasa, Eugen A.; Gurban, Dan

    2006-01-01

    Calcium hydroxide is used in dentistry and generally shows a clinically acceptable biocompatibility. However various commercial assortments show differences in their clinical performances, suggesting that certain aspects of their action are not completely understood and pointing to the necessity of new investigation methods. We report a preliminary study on two types of calcium hydroxide products carried out by thick target PIXE with 3.0 MeV protons, aiming to assess the potential of this method for the analysis of such biomaterials used in endodontic dentistry. (Semi)quantitative analysis was performed by use of reference materials, and relative concentrations of elements with respect to Ca were determined with an accuracy of about 30%; tentative absolute concentrations were also estimated by using Ca as a reference element. In both formulations, a number of trace elements (Mn, Fe, Zn and Sr, and possibly Cu and Pb - probably impurities from the raw materials) were evidenced. These trace elements together with the Ba/Ca ratio are reliable fingerprints for the identification of the materials, and evidenced a different origin for the Ca(OH) 2 used in the two specimens. Possible applications of PIXE in dental research may bring relevant compositional insight, and further studies of such materials are suggested. (authors)

  10. Ion-selective electrodes in organic elemental and functional group analysis: a review

    Energy Technology Data Exchange (ETDEWEB)

    Selig, W.

    1977-11-08

    The literature on the use of ion-selective electrodes in organic elemental and functional group analysis is surveyed in some detail. The survey is complete through Chemical Abstracts, Vol. 83 (1975). 40 figures, 52 tables, 236 references.

  11. Ion-selective electrodes in organic elemental and functional group analysis: a review

    International Nuclear Information System (INIS)

    Selig, W.

    1977-01-01

    The literature on the use of ion-selective electrodes in organic elemental and functional group analysis is surveyed in some detail. The survey is complete through Chemical Abstracts, Vol. 83 (1975). 40 figures, 52 tables, 236 references

  12. Finite element analysis of multilayer coextrusion.

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, Matthew Morgan; Schunk, Peter Randall; Baer, Thomas A. (Proctor & Gamble Company, West Chester, OH); Mrozek, Randy A. (Army Research Laboratory, Adelphi, MD); Lenhart, Joseph Ludlow (Army Research Laboratory, Adelphi, MD); Rao, Rekha Ranjana; Collins, Robert (Oak Ridge National Laboratory); Mondy, Lisa Ann

    2011-09-01

    Multilayer coextrusion has become a popular commercial process for producing complex polymeric products from soda bottles to reflective coatings. A numerical model of a multilayer coextrusion process is developed based on a finite element discretization and two different free-surface methods, an arbitrary-Lagrangian-Eulerian (ALE) moving mesh implementation and an Eulerian level set method, to understand the moving boundary problem associated with the polymer-polymer interface. The goal of this work is to have a numerical capability suitable for optimizing and troubleshooting the coextrusion process, circumventing flow instabilities such as ribbing and barring, and reducing variability in layer thickness. Though these instabilities can be both viscous and elastic in nature, for this work a generalized Newtonian description of the fluid is used. Models of varying degrees of complexity are investigated including stability analysis and direct three-dimensional finite element free surface approaches. The results of this work show how critical modeling can be to reduce build test cycles, improve material choices, and guide mold design.

  13. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  14. Preliminary In-Vivo Evaluation of Convex Array Synthetic Aperture Imaging

    DEFF Research Database (Denmark)

    Pedersen, Morten Høgholm; Gammelmark, Kim; Jensen, Jørgen Arendt

    2004-01-01

    of STA imaging in comparison to conventional imaging. The purpose is to evaluate whether STA imaging is feasible in-vivo. and whether the image quality obtained is comparable to traditional scanned imaging in terms of penetration depth, spatial resolution, contrast resolution, and artifacts. Acquisition...... was done using our RASMUS research scanner and a 5.5 MHz convex array transducer. STA imaging applies spherical wave emulation using multi-element subapertures and a 20 mus linear FM signal as excitation pulse. For conventional imaging a 64 element aperture was used in transmit and receive with a 1.5 cycle...

  15. Analysis of toxic elements and macro-micro nutrients in food stuff by using neutron activation analysis

    International Nuclear Information System (INIS)

    Rina Mulyaningsih, Th.; Istanto; Saeful Yusuf; Siti Suprapti

    2010-01-01

    Determination of toxic elements and macro-micro nutrient in food stuff by neutron activation analysis (NAA) has been done. The kinds of samples are vegetables, legume, mace and flavor, flour, fish and flesh. Samples had been collected from market in Serpong. Analysis of the samples show macro nutrients with concentration >1000 mg/kg, as K, Ca, Mg, Na, and Cl; micronutrients with concentration 10 - 100 mg/kg: Fe, Mn, Zn, Se, Br, Rb, and La; and toxic elements with concentration below 5 mg/kg as Co, Sb, Hg, As and Cr. As concentration in fish and rice and Hg concentration in fish and red chili is exceed from government permission value. Zinc concentration in some kind of samples is more than permission value, but it should be considered because of its average daily intake is lower then recommended value 15 mg/day. The Zn deficiencies can disturb growth and metabolism. Al concentration in samples is high enough 10 – 500 mg/kg; it must be take into account serious attention because of its toxicity. Evaluation of these elements is compared to sufficiency value of daily requirement RDA (Recommended Daily Acceptable). In this study was discussed potential hazards for human while its deficiencies or excessive intake. (author)

  16. Viscoelastic finite element analysis of residual stresses in porcelain-veneered zirconia dental crowns.

    Science.gov (United States)

    Kim, Jeongho; Dhital, Sukirti; Zhivago, Paul; Kaizer, Marina R; Zhang, Yu

    2018-06-01

    The main problem of porcelain-veneered zirconia (PVZ) dental restorations is chipping and delamination of veneering porcelain owing to the development of deleterious residual stresses during the cooling phase of veneer firing. The aim of this study is to elucidate the effects of cooling rate, thermal contraction coefficient and elastic modulus on residual stresses developed in PVZ dental crowns using viscoelastic finite element methods (VFEM). A three-dimensional VFEM model has been developed to predict residual stresses in PVZ structures using ABAQUS finite element software and user subroutines. First, the newly established model was validated with experimentally measured residual stress profiles using Vickers indentation on flat PVZ specimens. An excellent agreement between the model prediction and experimental data was found. Then, the model was used to predict residual stresses in more complex anatomically-correct crown systems. Two PVZ crown systems with different thermal contraction coefficients and porcelain moduli were studied: VM9/Y-TZP and LAVA/Y-TZP. A sequential dual-step finite element analysis was performed: heat transfer analysis and viscoelastic stress analysis. Controlled and bench convection cooling rates were simulated by applying different convective heat transfer coefficients 1.7E-5 W/mm 2 °C (controlled cooling) and 0.6E-4 W/mm 2 °C (bench cooling) on the crown surfaces exposed to the air. Rigorous viscoelastic finite element analysis revealed that controlled cooling results in lower maximum stresses in both veneer and core layers for the two PVZ systems relative to bench cooling. Better compatibility of thermal contraction coefficients between porcelain and zirconia and a lower porcelain modulus reduce residual stresses in both layers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Uncovering the Repertoire of Endogenous Flaviviral Elements in Aedes Mosquito Genomes.

    Science.gov (United States)

    Suzuki, Yasutsugu; Frangeul, Lionel; Dickson, Laura B; Blanc, Hervé; Verdier, Yann; Vinh, Joelle; Lambrechts, Louis; Saleh, Maria-Carla

    2017-08-01

    Endogenous viral elements derived from nonretroviral RNA viruses have been described in various animal genomes. Whether they have a biological function, such as host immune protection against related viruses, is a field of intense study. Here, we investigated the repertoire of endogenous flaviviral elements (EFVEs) in Aedes mosquitoes, the vectors of arboviruses such as dengue and chikungunya viruses. Previous studies identified three EFVEs from Aedes albopictus cell lines and one from Aedes aegypti cell lines. However, an in-depth characterization of EFVEs in wild-type mosquito populations and individual mosquitoes in vivo has not been performed. We detected the full-length DNA sequence of the previously described EFVEs and their respective transcripts in several A. albopictus and A. aegypti populations from geographically distinct areas. However, EFVE-derived proteins were not detected by mass spectrometry. Using deep sequencing, we detected the production of PIWI-interacting RNA-like small RNAs, in an antisense orientation, targeting the EFVEs and their flanking regions in vivo The EFVEs were integrated in repetitive regions of the mosquito genomes, and their flanking sequences varied among mosquito populations. We bioinformatically predicted several new EFVEs from a Vietnamese A. albopictus population and observed variation in the occurrence of those elements among mosquitoes. Phylogenetic analysis of an A. aegypti EFVE suggested that it integrated prior to the global expansion of the species and subsequently diverged among and within populations. The findings of this study together reveal the substantial structural and nucleotide diversity of flaviviral integrations in Aedes genomes. Unraveling this diversity will help to elucidate the potential biological function of these EFVEs. IMPORTANCE Endogenous viral elements (EVEs) are whole or partial viral sequences integrated in host genomes. Interestingly, some EVEs have important functions for host fitness and

  18. Development of an in vivo visual robot system with a magnetic anchoring mechanism and a lens cleaning mechanism for laparoendoscopic single-site surgery (LESS).

    Science.gov (United States)

    Feng, Haibo; Dong, Dinghui; Ma, Tengfei; Zhuang, Jinlei; Fu, Yili; Lv, Yi; Li, Liyi

    2017-12-01

    Surgical robot systems which can significantly improve surgical procedures have been widely used in laparoendoscopic single-site surgery (LESS). For a relative complex surgical procedure, the development of an in vivo visual robot system for LESS can effectively improve the visualization for surgical robot systems. In this work, an in vivo visual robot system with a new mechanism for LESS was investigated. A finite element method (FEM) analysis was carried out to ensure the safety of the in vivo visual robot during the movement, which was the most important concern for surgical purposes. A master-slave control strategy was adopted, in which the control model was established by off-line experiments. The in vivo visual robot system was verified by using a phantom box. The experiment results show that the robot system can successfully realize the expected functionalities and meet the demands of LESS. The experiment results indicate that the in vivo visual robot with high manipulability has great potential in clinical application. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Boundary element inverse analysis for rebar corrosion detection: Study on the 2004 tsunami-affected structure in Aceh

    Directory of Open Access Journals (Sweden)

    S. Fonna

    2018-06-01

    Full Text Available Evaluation of rebar/reinforcing-steel corrosion for the 2004 tsunami-affected reinforced concrete (RC buildings in Aceh was conducted using half-cell potential mapping technique. However, the results only show qualitative meaning as corrosion risk rather than the corrosion itself, such as the size and location of corrosion. In this study, boundary element inverse analysis was proposed to be performed to detect rebar corrosion of the 2004 tsunami-affected structure in Aceh, using several electrical potential measurement data on the concrete surface. One RC structure in Peukan Bada, an area heavily damaged by the tsunami, was selected for the study. In 2004 the structure was submerged more than 5 m by the tsunami. Boundary element inverse analysis was developed by combining the boundary element method (BEM and particle swarm optimization (PSO. The corrosion was detected by evaluating measured and calculated electrical potential data. The measured and calculated electrical potential on the concrete surface was obtained by using a half-cell potential meter and by performing BEM, respectively. The solution candidates were evaluated by employing PSO. Simulation results show that boundary element inverse analysis successfully detected the size and location of corrosion for the case study. Compared with the actual corrosion, the error of simulation result was less than 5%. Hence, it shows that boundary element inverse analysis is very promising for further development to detect rebar corrosion. Keywords: Inverse analysis, Boundary element method, PSO, Corrosion, Reinforced concrete

  20. Qualitative analysis of the rare earth element by simulation of inductively coupled plasma emission spectra

    International Nuclear Information System (INIS)

    Hashimoto, M.S.; Tobishima, Taeko; Kamitake, Seigo; Yasuda, Kazuo.

    1985-01-01

    The emission lines for qualitative analysis of rare earth elements by a simulation technique of ICP spectra were proposed. The spectra were simulated by employing a Gaussian (or a Lorentzian at high concentrations) profile. The simulated spectra corresponded quite well with the observed ones. The emission lines were selected so that the interference was as small as possible. The present qualitative analysis is based on a pattern recognition method where observed intensity ratios of the emission lines in each element are compared with those of a single analyte element. The qualitative analysis was performed for twelve standard solutions containing a single rare earth element and for eight standard solutions containing an element other than rare earth elements. The selection of the emission lines and the algorithm of the present qualitative analysis were justified. (author)

  1. Spinal cord dopamine D2/D3 receptors: in vivo and ex vivo imaging in the rat using 18F/11C-fallypride

    International Nuclear Information System (INIS)

    Kaur, Jasmeet; Khararjian, Armen; Coleman, Robert A.; Constantinescu, Cristian C.; Pan, Min-Liang; Mukherjee, Jogeshwar

    2014-01-01

    Objectives: The spinal cord is known to be innervated with dopaminergic cells with catecholaminergic projections arising from the medulla and pons and dopaminergic transmission in the spinal cord is vital for sensory and motor function. Our goal was to evaluate and compare the imaging capability of dopamine D2/D3 receptors in the rat spinal cord using PET ligands 18 F-fallypride and 11 C-fallypride. Methods: Male Sprague–Dawley rats were used in all in vitro and in vivo studies. Spinal cord and brain sections were used for in vitro autoradiography and ex vivo autoradiography. For in vivo studies animals received a 18 F-fallypride scan or a 11 C-fallypride PET scan. The spinal cord and the brain were then harvested, flash-frozen and imaged ex vivo. For in vivo analysis Logan plots with cerebellum as a reference was used to evaluate binding potentials (BP). Tissue ratios were used for ex vivo analysis. Drug effects were evaluated using clozapine, haloperidol and dopamine were evaluated on spinal cord sections in vitro. Results: In vitro studies showed 18 F-fallypride binding to superficial dorsal horn (SDH), dorsal horn (DH), ventral horn (VH) and the pars centralis (PC). In the cervical section, the greatest amount of binding appeared to be in the SDH. Ex vivo studies showed approximately 6% of 18 F-fallypride in SDH compared to that observed in the striatum. In vivo analysis of both 18 F-fallypride and 11 C-fallypride in the spinal cord were comparable to that in the extrastriatal regions. Haloperidol and clozapine displaced more than 75% of the 18 F-fallypride in spinal cord sections. Conclusions: Our studies showed 18 F-fallypride and 11 C-fallypride binding in the spinal cord in vitro and in vivo. The binding pattern correlates well with the known distribution of dopamine D2/D3 receptors in the spinal cord

  2. Towards in vivo regulon kinetics: PurR activation by 5-phosphoribosyl-a-1-pyrophosphate during purine depletion in Lactococcus lactis

    DEFF Research Database (Denmark)

    Jendresen, Christian Bille; Dimitrov, Peter; Gautier, Laurent

    2014-01-01

    Short-term adaptation to changing environments relies on regulatory elements translating shifting metabolite concentrations into a specifically optimized transcriptome. So far the focus of analyses has been divided between regulatory elements identified in vivo and kinetic studies of small molecu...

  3. Advanced Imaging Approaches to Characterize Stromal and Metabolic Changes in In Vivo Mammary Tumor Models

    Science.gov (United States)

    2015-02-01

    Bird , L. Yan, K. M. Vrotsos, K. W. Eliceiri, E. M. Vaughan, P. J. Keely, J. G. White, N. Ramanujam, Metabolic mapping of MCF10A human breast cells...1   Award Number: W81XWH-12-1-0025 TITLE: Advanced Imaging Approaches to Characterize Stromal and Metabolic Changes in In Vivo Mammary... Metabolic Changes in In Vivo Mammary Tumor Models 5b. GRANT NUMBER BC112240 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Betty Diamond 5d. PROJECT NUMBER

  4. Analysis of the elements sputtered during the lanthanum implantation in stainless steels

    International Nuclear Information System (INIS)

    Ager, F.J.; Respaldiza, M.A.; Silva, M.F. da; Redondo, L.M.; Soares, J.C.

    1998-01-01

    The evidence of the modification of the surface structure of the AISI-304 stainless steel during the implantation of lanthanum makes the analysis of the sputtered elements very interesting. Those sputtered elements are deposited on a carbon sheet placed in front of the steel being implanted, and studied by means of RBS and PIXE, together with the implanted specimens. Besides, the protective effect of the implanted ions during the high temperature oxidation is also studied by those techniques together with XRD and thermogravimetric methods. (orig.)

  5. Comprehensive multilevel in vivo and in vitro analysis of heart rate fluctuations in mice by ECG telemetry and electrophysiology.

    Science.gov (United States)

    Fenske, Stefanie; Pröbstle, Rasmus; Auer, Franziska; Hassan, Sami; Marks, Vanessa; Pauza, Danius H; Biel, Martin; Wahl-Schott, Christian

    2016-01-01

    The normal heartbeat slightly fluctuates around a mean value; this phenomenon is called physiological heart rate variability (HRV). It is well known that altered HRV is a risk factor for sudden cardiac death. The availability of genetic mouse models makes it possible to experimentally dissect the mechanism of pathological changes in HRV and its relation to sudden cardiac death. Here we provide a protocol that allows for a comprehensive multilevel analysis of heart rate (HR) fluctuations. The protocol comprises a set of techniques that include in vivo telemetry and in vitro electrophysiology of intact sinoatrial network preparations or isolated single sinoatrial node (SAN) cells. In vitro preparations can be completed within a few hours, with data acquisition within 1 d. In vivo telemetric ECG requires 1 h for surgery and several weeks for data acquisition and analysis. This protocol is of interest to researchers investigating cardiovascular physiology and the pathophysiology of sudden cardiac death.

  6. Class I gene regulation of haplotype preference may influence antiviral immunity in vivo

    DEFF Research Database (Denmark)

    Thomsen, Allan Randrup; Marker, O

    1989-01-01

    targets. In regard to the in vivo significance of haplotype preference it was found that (C X C3) F1 mice expressed an earlier and stronger virus-specific delayed type hypersensitivity response and exerted a more efficient virus control than did (C-H-2dm2 X C3) F1. Taken together these findings suggest...... that haplotype preference reflects a selection process favoring the restriction element associated with the most efficient immune response in vivo. The implications of this are discussed....

  7. Determination of trace elements in lichen samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Coccaro, D.M.B.; Vasconcellos, M.B.A.; Marcelli, M.P.

    1999-01-01

    Epiphytic lichens have been used as bioindicators of environmental pollution studies because of their ability to accumulate metals present in the atmosphere at very low concentrations. In this work, experimental conditions for collection and preparation of the lichen samples as well as the experimental procedure for neutron activation analysis were established in order to obtain reliable and useful data for environmental monitoring purposes. Lichen samples were collected from the barks of trees. They were first examined in a stereo microscope, cleaned and then they were washed with water, freeze-dried and ground for analysis. Out of the five species Usnea sp, Parmotrena tinctorum, Canoparmelia caroliniana, Parmotrema sanctiangeli and Canoparmelia texana analysed, the latter was chosen for this work since this species is very abundant on the Brazilian territory except for the coast. The samples and synthetic standards of elements were irradiated at the IEA-R1 nuclear reactor and the concentrations of the elements Al, As, Br, Ca, Cd, Cl, Co, Cr, Cs, Fe, K, lanthanides, Mg, Mn, Na, Rb, Sb, Sc, Se, Th, U, V and Zn were determined by using short and long irradiations. Results obtained in the washed and unwashed lichen samples showed that the cleaning with water can be used in order to eliminate adhering materials. Indeed, most of elements of interest for the environmental contamination accumulated by the lichens were not removed. The study of the influence of the age of the lichen indicated that its elemental concentrations increase with its age or with the length of exposure. Results obtained for lichens collected from four different trees in the same sampling area varied from about 3.4 to 50%. The homogeneity of the sample was checked by analyzing replicates. The precision and the accuracy of the method were evaluated by analyzing IAEA 336 Lichen and NIST 1752 Citrus Leaves. (author)

  8. Determination of trace elements in human brain tissues using neutron activation analysis

    International Nuclear Information System (INIS)

    Leite, R.E.P.; Jacob-Filho, W.; Grinberg, L.T.; Ferretti, R.E.L.

    2008-01-01

    Neutron activation analysis was applied to assess trace element concentrations in brain tissues from normal (n = 21) and demented individuals (n = 21) of both genders aged more than 50 years. Concentrations of the elements Br, Fe, K, Na, Rb, Se and Zn were determined. Comparisons were made between the results obtained for the hippocampus and frontal cortex tissues, as well as, those obtained in brains of normal and demented individuals. Certified reference materials, NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver were analyzed for quality of the analytical results. (author)

  9. Use of personal computers in performing a linear modal analysis of a large finite-element model

    International Nuclear Information System (INIS)

    Wagenblast, G.R.

    1991-01-01

    This paper presents the use of personal computers in performing a dynamic frequency analysis of a large (2,801 degrees of freedom) finite-element model. Large model linear time history dynamic evaluations of safety related structures were previously restricted to mainframe computers using direct integration analysis methods. This restriction was a result of the limited memory and speed of personal computers. With the advances in memory capacity and speed of the personal computers, large finite-element problems now can be solved in the office in a timely and cost effective manner. Presented in three sections, this paper describes the procedure used to perform the dynamic frequency analysis of the large (2,801 degrees of freedom) finite-element model on a personal computer. Section 2.0 describes the structure and the finite-element model that was developed to represent the structure for use in the dynamic evaluation. Section 3.0 addresses the hardware and software used to perform the evaluation and the optimization of the hardware and software operating configuration to minimize the time required to perform the analysis. Section 4.0 explains the analysis techniques used to reduce the problem to a size compatible with the hardware and software memory capacity and configuration

  10. Trace element analysis in soy sauce

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomiya, Michio

    1993-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mn, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of Br about 160 ppm. Comparison of Br content of the imported raw materials with those of the domestic ones suggested that the large amount of Br was the residual fumigation chemicals in the imported raw materials. (author)

  11. Electromagnetic analysis of control element drive mechanism for KSNP

    International Nuclear Information System (INIS)

    Kim, H. M.; Kim, I. G.; Kim, I. Y.

    2002-01-01

    The magnetic jack type Control Element Drive Mechanism (CEDM) for Korean Standard Nuclear Power Plant (KSNP) is an electromechanical device which provides controlled linear motion to the Control Element Assembly (CEA) through the Extension Shaft Assembly (ESA) in response to operational signals received from the Control Element Drive Mechanism Control System (CEDMCS). The CEDM is operated by applying localized magnetic flux fields to movable latch and lift magnets, which are in the coolant pressure boundary. The CEDM design had been developed through electromechanical testing of the system including the magnetic force lifting the ESA. But it will be inefficient if parametric studies should be performed to improve the CEDM by test due to the consumption of high cost and long duration. So it becomes necessary to develop a computational model to simulate the electromagnetic characteristics of the CEDM to improve the CEDM design efficiently. In this paper, the electromagnetic analysis using a 2D finite element model has been carried out to simulate magnetic force of the lift magnet of the CEDM, to provide effective evaluation between leakage flux and lift force and to compare with test results. Analysis results show the lift force satisfied the test results and design requirement and the lift force depend on the shape of the components, leakage flux and B-H curve

  12. In Vivo Clonal Analysis Reveals Lineage-Restricted Progenitor Characteristics in Mammalian Kidney Development, Maintenance, and Regeneration

    Directory of Open Access Journals (Sweden)

    Yuval Rinkevich

    2014-05-01

    Full Text Available The mechanism and magnitude by which the mammalian kidney generates and maintains its proximal tubules, distal tubules, and collecting ducts remain controversial. Here, we use long-term in vivo genetic lineage tracing and clonal analysis of individual cells from kidneys undergoing development, maintenance, and regeneration. We show that the adult mammalian kidney undergoes continuous tubulogenesis via expansions of fate-restricted clones. Kidneys recovering from damage undergo tubulogenesis through expansions of clones with segment-specific borders, and renal spheres developing in vitro from individual cells maintain distinct, segment-specific fates. Analysis of mice derived by transfer of color-marked embryonic stem cells (ESCs into uncolored blastocysts demonstrates that nephrons are polyclonal, developing from expansions of singly fated clones. Finally, we show that adult renal clones are derived from Wnt-responsive precursors, and their tracing in vivo generates tubules that are segment specific. Collectively, these analyses demonstrate that fate-restricted precursors functioning as unipotent progenitors continuously maintain and self-preserve the mouse kidney throughout life.

  13. Membrane versus shell type elements in F.E. analysis of box type buildings

    International Nuclear Information System (INIS)

    Canetta, G.

    1979-01-01

    Finite element analysis of box-type buildings is discussed under typical loading conditions - gravity, seismic and temperature loads. The computation effort is recognized to be noticeably different, according to whether membrane or shell type elements are used. The relevance of membrane and bending stress components to the total stress distribution is outlined in the table below; the different role of the typical members under the various loading conditions is emphasized. (orig.)

  14. Nonlinear Finite Element Analysis of Reinforced Concrete Shells

    Directory of Open Access Journals (Sweden)

    Mustafa K. Ahmed

    2013-05-01

    Full Text Available This investigation is to develop a numerical model suitable for nonlinear analysis of reinforced concrete shells. A nine-node Lagrangian element Figure (1 with enhanced shear interpolation will be used in this study. Table (1 describes shape functions and their derivatives of this element.An assumed transverse shear strain is used in the formulation of this element to overcome shear locking. Degenerated quadratic thick plate elements employing a layered discrelization through the thickness will be adopted. Different numbers of layers for different thickness can be used per element. A number of layers between (6 and 10 have proved to be appropriate to represent the nonlinear material behavior in structures. In this research 8 layers will be adequate. Material nonlinearities due to cracking of concrete, plastic flow or crushing of concrete in compression and yield condition of reinforcing steel are considered. The maximum tensile strength is used as a criterion for crack initiation. Attention is given to the tension stiffening phenomenon and the degrading effect of cracking on the compressive and shear strength of concrete. Perfect bond between concrete and steel is assumed. Attention is given also to geometric nonlinearities. An example have been chosen in order to demonstrate the suitability of the models by comparing the predicted behaviour with the experimental results for shell exhibiting various modes of failure.

  15. Comparison and determination of elemental composition in Korean space foods using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong-Sam Chung; Sun-Ha Kim; Gwang-Min Sun; Jong-Hwa Moon; Jong-Il Choi; Beom-Seok Song; Jae-Hun Kim

    2013-01-01

    A quantitative analysis of mineral contents in several kinds of foods is needed to obtain information on a comprehensive elemental composition as well as an investigation on the effects of human health and nutrition based on the dietary intake of mineral elements. In 2012, six kinds of new Korean space foods (KSF) such as sweet pumpkin porridge, dakgalbi (spicy grilled chicken), Manila clam porridge, ox leg bone-cabbage soup, ginseng-chicken porridge, and chicken curry rice were developed by KAERI, and the contents of more than 15 elements in the samples were determined using an instrumental neutron activation analysis. A certified reference material associated with a biological food sample was used for analytical quality control. The analytical results were evaluated according to the elemental concentrations with KSF samples and compared with the reported values. These results will be applied toward the identification of gamma-irradiated foods. (author)

  16. The use of physical methods for elemental analysis of ecological samples

    International Nuclear Information System (INIS)

    Kudryashov, V.I.; Zhuravleva, E.L.; Maslov, O.D.

    1996-01-01

    The possibility of the application of difference X-ray and instrumental activation methods elemental analysis of rock ice, snow, water, soil and other natural samples was investigated. The content of some elements in ice samples from the glaciers of the Pamirs-Alaj mountain system for period 1973-1984 years has been determined. The recommendations for the choice of analysis methods with the aim of the environmental control have been given. (author). 10 refs., 6 figs., 1 tab

  17. Analysis of inorganic elements in biological samples of C57BL/6J mouse strain using INAA

    Energy Technology Data Exchange (ETDEWEB)

    Metairon, Sabrina; Zamboni, Cibele B.; Suzuki, Miriam F.; Kovacs, Luciana, E-mail: metairon@usp.br, E-mail: czamboni@ipen.br, E-mail: mfsuzuki@ipen.br, E-mail: lukovacs@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Bueno Junior, Carlos R., E-mail: carmao11@yahoo.com.br [Universidade de Sao Paulo (IB/USP), Sao Paulo, SP (Brazil). Instituto de Biociencias. Centro de Estudos do Genoma Humano

    2013-07-01

    The research for new medicine, vaccines and other products of interest in health area, for any disease, requires several in vivo tests using animal models on experiments for clinical analysis of actions in organism, focusing on the relation between these and the responses or reactions to their use, allowing or not their use in human being. The present investigation deals with the determination of elements concentration (Ca, Cl, K, Mg and Na) of clinical relevance in kidney and liver of C57BL/6J mice strain using the Instrumental Neutron Activation Analysis technique. Particularly, the C57BL/6J strain is one of the most widely used mice genetically modified for human disease studies. The biological samples were collected from 2 month old adult mice bred in the Biotherium (animal breeding) of UNIFESP (Federal University of Sao Paulo, Brasil) and at Human Genome Research Center (University of Sao Paulo, Brasil) and Biotechnology Center (IPEN, Sao Paulo, Brasil). The measurements were performed in the nuclear reactor IEA-R1 (3.5-4.5MW, pool type) at IPEN. These data will allow researchers to optimize their studies, both in terms of cost and time, by knowing the basal reference values in blood and organs of this strain. Additionally, this analytical procedure meets the needs of the world tendency that emphasizes the requirements to propose alternative methods for clinical research that contribute to animal welfare. (author)

  18. Analysis of inorganic elements in biological samples of C57BL/6J mouse strain using INAA

    International Nuclear Information System (INIS)

    Metairon, Sabrina; Zamboni, Cibele B.; Suzuki, Miriam F.; Kovacs, Luciana; Bueno Junior, Carlos R.

    2013-01-01

    The research for new medicine, vaccines and other products of interest in health area, for any disease, requires several in vivo tests using animal models on experiments for clinical analysis of actions in organism, focusing on the relation between these and the responses or reactions to their use, allowing or not their use in human being. The present investigation deals with the determination of elements concentration (Ca, Cl, K, Mg and Na) of clinical relevance in kidney and liver of C57BL/6J mice strain using the Instrumental Neutron Activation Analysis technique. Particularly, the C57BL/6J strain is one of the most widely used mice genetically modified for human disease studies. The biological samples were collected from 2 month old adult mice bred in the Biotherium (animal breeding) of UNIFESP (Federal University of Sao Paulo, Brasil) and at Human Genome Research Center (University of Sao Paulo, Brasil) and Biotechnology Center (IPEN, Sao Paulo, Brasil). The measurements were performed in the nuclear reactor IEA-R1 (3.5-4.5MW, pool type) at IPEN. These data will allow researchers to optimize their studies, both in terms of cost and time, by knowing the basal reference values in blood and organs of this strain. Additionally, this analytical procedure meets the needs of the world tendency that emphasizes the requirements to propose alternative methods for clinical research that contribute to animal welfare. (author)

  19. Determination of 25 elements in biological standard reference materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Guzzi, G.; Pietra, R.; Sabbioni, E.

    1974-12-01

    Standard and Certified Reference Materials programme of the JRC includes the determination of trace elements in complex biological samples delivered by the U.S. National Bureau of Standards: Bovine liver (NBS SRM 1577), Orchard Leaves (NBS SRM 1571) and Tomato Leaves. The study has been performed by the use of neutron activation analysis. Due to the very low concentration of some elements, radiochemical groups or elemental separation procedures were necessary. The paper describes the techniques used to analyse 25 elements. Computer assisted instrumental neutron activation analysis with high resolution Ge(Li) spectrometry was considerably advantageous in the determination of Na, K, Cl, Mn, Fe, Rb and Co and in some cases of Ca, Zn, Cs, Sc, and Cr. For low contents of Ca, Mg, Ni and Si special chemical separation schemes, followed by Cerenkov counting have been developped. Two other separation procedures allowing the determination of As, Cd, Ga, Hg, Mo, Cu, Sr Se, Ba and P have been set up. The first, the simplified one involves the use of high resolution Ge(Li) detectors, the second, the more complete one involves a larger number of shorter measurements performed by simpler and more sensitive techniques, such as NaI(Tl) scintillation spectrometry and Cerenkov counting. The results obtained are presented and discussed

  20. Optimization of data analysis for the in vivo neutron activation analysis of aluminum in bone.

    Science.gov (United States)

    Mohseni, H K; Matysiak, W; Chettle, D R; Byun, S H; Priest, N; Atanackovic, J; Prestwich, W V

    2016-10-01

    An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5μg Al/g Ca) compared to the inverse-variance weighted mean (5.2μg Al/g Ca), rendering both equally applicable to human measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Comparative analysis of C A R A fuel element in argentinean PHWR Argentinas

    International Nuclear Information System (INIS)

    Brasnarof D; Marino, A. C; Florido, P. C; Daverio, H

    2006-01-01

    This paper presents an analysis of the thermal mechanical behaviour, fuel consumption and economical estimations of the CARA fuel element in the Atucha and Embalse nuclear power plants, compared with the present fuel performance.The present results show that the expect profit by the use of the CARA fuel element in our reactor guaranties the recovery of fund for its development. Likewise it reduces the number of spent fuel to be storage and treated [es

  2. Finite element analysis of helical flows in human aortic arch: A novel index

    OpenAIRE

    Lee, Cheng-Hung; Liu, Kuo-Sheng; Jhong, Guan-Heng; Liu, Shih-Jung; Hsu, Ming-Yi; Wang, Chao-Jan; Hung, Kuo-Chun

    2014-01-01

    This study investigates the helical secondary flows in the aortic arch using finite element analysis. The relationship between helical flow and the configuration of the aorta in patients of whose three-dimensional images constructed from computed tomography scans was examined. A finite element model of the pressurized root, arch, and supra-aortic vessels was developed to simulate the pattern of helical secondary flows. Calculations indicate that most of the helical secondary flow was formed i...

  3. Dissipation element analysis of turbulent scalar fields

    International Nuclear Information System (INIS)

    Wang Lipo; Peters, Norbert

    2008-01-01

    Dissipation element analysis is a new approach for studying turbulent scalar fields. Gradient trajectories starting from each material point in a scalar field Φ'(x-vector,t) in ascending directions will inevitably reach a maximal and a minimal point. The ensemble of material points sharing the same pair ending points is named a dissipation element. Dissipation elements can be parameterized by the length scale l and the scalar difference Δφ ', which are defined as the straight line connecting the two extremal points and the scalar difference at these points, respectively. The decomposition of a turbulent field into dissipation elements is space-filling. This allows us to reconstruct certain statistical quantities of fine scale turbulence which cannot be obtained otherwise. The marginal probability density function (PDF) of the length scale distribution based on a Poisson random cutting-reconnection process shows satisfactory agreement with the direct numerical simulation (DNS) results. In order to obtain the further information that is needed for the modeling of scalar mixing in turbulence, such as the marginal PDF of the length of elements and all conditional moments as well as their scaling exponents, there is a need to model the joint PDF of l and Δφ ' as well. A compensation-defect model is put forward in this work to show the dependence of Δφ ' on l. The agreement between the model prediction and DNS results is satisfactory, which may provide another explanation of the Kolmogorov scaling and help to improve turbulent mixing models. Furthermore, intermittency and cliff structure can also be related to and explained from the joint PDF.

  4. Principle of neutron activation analysis and its use for determination of trace elements in sediment

    International Nuclear Information System (INIS)

    Verma, Rakesh

    2012-01-01

    Neutron Activation analysis (NAA) is a multi element analysis technique, often non-destructive in nature where approximately 75 elements can be measured with the detection limits ranging from 10 -6 to 10 -12 g of element in a sample. Typical sample sizes range from 1 mg to 1 g, however in principle much larger samples can be activated and the size is only limited by the capacity of the neutron irradiation facility. In NAA, a sample (solid or liquid or gas) is exposed to neutrons and radiations emitted by the radioactive products, formed during the nuclear reaction, are measured using a suitable detector. The energy of the emitted radiation is a characteristic of a radioisotope whereas the intensity of the emitted radiation is proportional to the mass of the analyte. NAA can be carried out by measurement of (i) prompt gamma rays emitted by compound nucleus, called prompt gamma ray NAA (PGNAA) and (ii) β rays emitted from radioactive product or delayed gamma rays emitted subsequent to β decay, called conventional NAA or simply NAA. PGNAA is an online measurement method. PGNAA is complementary to conventional NAA in terms of analyzing low Z elements. Conventional NAA is an offline method and is easy to perform. Depending upon the nature of matrix and analyte to be determined, three approaches are possible in NAA namely, (i) instrumental neutron activation analysis (INAA), (ii) radiochemical neutron activation analysis (RNAA), and (iii) chemical neutron activation analysis (CNAA). Quantification is accomplished by any of the three standardisation methodologies namely (i) absolute method (ii) relative method and (iii) single comparator method. The relative method is most precise and simple to perform. Natural processes responsible for the formation of bottom sediments can be altered by anthropogenic activities. Bottom sediments are a sink as well as a source of contaminants in the aquatic environment. Analysis of-sediments provides environmentally significant

  5. Neutron activation analysis for environmental trace element research determination of elemental composition of sediments in the Sea of Galillee, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Lavi, N; Ne` eman, E; Brenner, S; Butenko, V [Tel Aviv Univ. (Israel). Medical School

    1996-12-01

    The aims of this work were to: a) demonstrate the effectiveness of instrumental neutron activation analysis for determining the background concentrations of trace elements in the sediments collected from the Sea of Gallile. b) determine the advantage factors for epithermal neutron irradiation. c) determine the contribution of silicon to the total {sup 28}Al activity by the {sup 28}Si(n,p){sup 28}Al reaction. c) check the validity of the method by determining the elemental content of U.S. NBS Standard Reference Material SRM-1633a (fly ash). d) calculate the average enrichment factors for the elements in sediments . e) determine the concentrations of the artificial radionuclides {sup 134}Cs, {sup 137}Cs and the naturally occurring radionuclides {sup 40}K, {sup 226}Ra and {sup 232}Th (authors).

  6. Nonlinear Finite Element Analysis of Pull-Out Test

    DEFF Research Database (Denmark)

    Saabye Ottesen, N

    1981-01-01

    A specific pull-out test used to determine in-situ concrete compressive strength is analyzed. This test consists of a steel disc that is extracted from the structure. The finite element analysis considers cracking as well as strain hardening and softening in the pre- and post-failure region...

  7. Finite element analysis of inelastic structural behavior

    International Nuclear Information System (INIS)

    Argyris, J.H.; Szimmat, J.; Willam, K.J.

    1977-01-01

    The paper describes recent achievements in the finite element analysis of inelastic material behavior. The main purpose is to examine the interaction of three disciplines; (i) the finite element formulation of large deformation problems in the light of a systematic linearization, (ii) the constitutive modelling of inelastic processes in the rate-dependent and rate-independent response regime and (iii) the numerical solution of nonlinear rate problems via incremental iteration techniques. In the first part, alternative finite element models are developed for the idealization of large deformation problems. A systematic approach is presented to linearize the field equations locally by an incremental procedure. The finite element formulation is then examined for the description of inelastic material processes. In the second part, nonlinear and inelastic material phenomena are classified and illustrated with representative examples of concrete and metal components. In particular, rate-dependent and rate-independent material behavior is examined and representative constitutive models are assessed for their mathematical characterization. Hypoelastic, elastoplastic and endochronic models are compared for the description rate-independent material phenomena. In the third part, the numerial solution of inelastic structural behavior is discussed. In this context, several incremental techniques are developed and compared for tracing the evolution of the inelastic process. The numerical procedures are examined with regard to stability and accuracy to assess the overall efficiency. The 'optimal' incremental technique is then contrasted with the computer storage requirements to retain the data for the 'memory-characteristics' of the constitutive model

  8. Trace elements detection in whole food samples by Neutron Activation Analysis, k0-method

    International Nuclear Information System (INIS)

    Sathler, Márcia Maia; Menezes, Maria Ângela de Barros Correia; Salles, Paula Maria Borges de

    2017-01-01

    Inorganic elements, from natural and anthropogenic sources are present in foods in different concentrations. With the increase in anthropogenic activities, there was also a considerable increase in the emission of these elements in the environment, leading to the need of monitoring the elemental composition of foods available for consumption. Numerous techniques have been used to detect inorganic elements in biological and environmental matrices, always aiming at reaching lower detection limits in order to evaluate the trace element content in the sample. Neutron activation analysis (INAA), applying the k 0 -method, produces accurate and precise results without the need of chemical preparation of the samples – that could cause their contamination. This study evaluated the presence of inorganic elements in whole foods samples, mainly elements on trace levels. For this purpose, seven samples of different types of whole foods were irradiated in the TRIGA MARK I IPR-R1 research reactor - located at CDTN/CNEN, in Belo Horizonte, MG. It was possible to detect twenty two elements above the limit of detection in, at least, one of the samples analyzed. This study reaffirms the INAA, k 0 - method, as a safe and efficient technique for detecting trace elements in food samples. (author)

  9. Needle Type Solid State Detectors for In-Vivo Measurement of Tracer Activity

    Energy Technology Data Exchange (ETDEWEB)

    Lauber, A [AB Atomenergi, Nykoeping (Sweden); Wolgast, W [Univ. of Uppsala (Sweden). Inst. of Physiology and Medical Biophysics

    1970-07-15

    A set of miniature detector probes for in-vivo-measurement of beta and gamma tracer activity is described. The probes use a lithium-compensated p-i-n silicon detector as sensing element. The standard 'needle probe' contains a cylindrical detector 0.9 mm in diameter and 3 mm long, enclosed in a stainless steel tube 1.1 mm in outer diameter and with walls 0. 05 mm thick. For particular applications several modified types have been developed: probes with larger sensing elements, probes with extra thin walls for low-energy beta detection, probes with two or three sensing elements in the same needle and probes containing a movable sensing element. This report describes the construction and the properties of the different needle probes.

  10. Needle Type Solid State Detectors for In-Vivo Measurement of Tracer Activity

    International Nuclear Information System (INIS)

    Lauber, A.; Wolgast, W.

    1970-07-01

    A set of miniature detector probes for in-vivo-measurement of beta and gamma tracer activity is described. The probes use a lithium-compensated p-i-n silicon detector as sensing element. The standard 'needle probe' contains a cylindrical detector 0.9 mm in diameter and 3 mm long, enclosed in a stainless steel tube 1.1 mm in outer diameter and with walls 0. 05 mm thick. For particular applications several modified types have been developed: probes with larger sensing elements, probes with extra thin walls for low-energy beta detection, probes with two or three sensing elements in the same needle and probes containing a movable sensing element. This report describes the construction and the properties of the different needle probes

  11. Multi-element trace analysis of solid samples using one-photon two-step RIMS

    International Nuclear Information System (INIS)

    Telle, H. H.; Abraham, C. J.; Jones, O. R.; Krustev, T.

    1998-01-01

    In this study we have investigated the feasibility of multi-element analysis using a simple 1+1 photo-excitation/photo-ionization scheme. Although such schemes are usually far from ideal for optimum resonance ionization, they are the approach of choice if one wishes to maintain a simple, easy-to-operate laser set-up which is potentially suitable for routine analysis. In addition, we only made use of the second-harmonic tuning range of a single dye. While this limits the range of elements which are accessible in the 1+1 RIS scheme it further adds to the simplicity and allows for automation of sequential multi-element analysis

  12. Piezoelectric Analysis of Saw Sensor Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Vladimír KUTIŠ

    2013-06-01

    Full Text Available In this contribution modeling and simulation of surface acoustic waves (SAW sensor using finite element method will be presented. SAW sensor is made from piezoelectric GaN layer and SiC substrate. Two different analysis types are investigated - modal and transient. Both analyses are only 2D. The goal of modal analysis, is to determine the eigenfrequency of SAW, which is used in following transient analysis. In transient analysis, wave propagation in SAW sensor is investigated. Both analyses were performed using FEM code ANSYS.

  13. Lipidots: competitive organic alternative to quantum dots for in vivo fluorescence imaging

    Science.gov (United States)

    Gravier, Julien; Navarro, Fabrice P.; Delmas, Thomas; Mittler, Frédérique; Couffin, Anne-Claude; Vinet, Françoise; Texier, Isabelle

    2011-09-01

    The use of fluorescent nanostructures can bring several benefits on the signal to background ratio for in vitro microscopy, in vivo small animal imaging, and image-guided surgery. Fluorescent quantum dots (QDs) display outstanding optical properties, with high brightness and low photobleaching rate. However, because of their toxic element core composition and their potential long term retention in reticulo-endothelial organs such as liver, their in vivo human applications seem compromised. The development of new dye-loaded (DiO, DiI, DiD, DiR, and Indocyanine Green (ICG)) lipid nanoparticles for fluorescence imaging (lipidots) is described here. Lipidot optical properties quantitatively compete with those of commercial QDs (QTracker®705). Multichannel in vivo imaging of lymph nodes in mice is demonstrated for doses as low as 2 pmols of particles. Along with their optical properties, fluorescent lipidots display very low cytotoxicity (IC50 > 75 nM), which make them suitable tools for in vitro, and especially in vivo, fluorescence imaging applications.

  14. In vivo neutron activation analysis in a study of cadmium and hypertension in South Wales

    International Nuclear Information System (INIS)

    Morgan, W.D.; Cummins, P.E.; Elwood, P.C.; Evans, C.J.; Dutton, J.; Sivyer, A.

    1980-01-01

    There is conflicting evidence concerning the influence of cadmium on the incidence of essential hypertension. Blood and urine are not very good indicators of body burden, and furthermore, the importance in such studies of matching for age and smoking habit has often been overlooked. In this respect, the technique for cadmium measurements in vivo by neutron capture prompt gamma analysis has many advantages. Fast neutron irradiation of a subject generates a thermal neutron flux at depths within the body such that capture reactions may occur. These will take place predominantly with hydrogen but also with cadmium and other body elements depending upon their cross-section and tissue abundance. The characteristic 559 keV prompt gamma rays from cadmium are detected using a 21% efficient Ge(Li) detector which is shielded against neutron and gamma radiation emerging both from the source and shield and from the subject. A detection limit (2 s.d. of the background) of 3.2 mg cadmium in the kidney is achieved for an organ dose of 0.3 rem delivered in 33 min. A study of 30 hypertensive subjects and 30 controls, matched for age, sex and smoking habit, has shown a mean kidney cadmium content of 3.3 +- 2.3 mg in the hypertensives which is not significantly different from the 4.4 +- 2.7 mg in the controls. However, in 13 pairs of non-smokers within the study, the mean value of 2.4 +- 2.5 mg in the hypertensives was significantly (p < 0.05) lower than the 3.9 +- 1.2 mg observed in the controls. Since the hypertensive patients had been treated for several years this raises the question of whether such therapy has reduced the level of renal cadmium below that which might be found in untreated hypertensives. Finally, the study confirmed the previously reported association between cigarette smoking and cadmium burden

  15. Analysis of central enterprise architecture elements in models of six eHealth projects.

    Science.gov (United States)

    Virkanen, Hannu; Mykkänen, Juha

    2014-01-01

    Large-scale initiatives for eHealth services have been established in many countries on regional or national level. The use of Enterprise Architecture has been suggested as a methodology to govern and support the initiation, specification and implementation of large-scale initiatives including the governance of business changes as well as information technology. This study reports an analysis of six health IT projects in relation to Enterprise Architecture elements, focusing on central EA elements and viewpoints in different projects.

  16. Major and minor elements analysis in soil samples by neutron activation analysis and X-ray fluorescence

    International Nuclear Information System (INIS)

    Morcelli, Claudia Petronilho Ribeiro; Ana Maria Graciano; Enzweiler, Jacinta

    2002-01-01

    In the present work, Instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence were employed to analyze major and minor elements in soil samples collected near Bandeirantes road. Elements of environmental interest, such as Al, Sb, As, Ba, Cd, Pb, Co, Cu, Cr, Fe, Mn, Mo, Ni, Se, V and Zn, which have reference background levels, were determined. The samples were dried in an oven at 40 deg C, were sieved (<2 mm), grinded and were analyzed by INAA and FRX. The aims of this work were: to evaluate the possible variations in the concentration levels in soil due to emission of particulate from vehicles and other anthropogenic sources; to compare the results obtained by using both techniques. This preliminary study showed that the concentration levels of the elements of environmental interest agree with reference values for tropical soils in the sampling sites, except for Ba, which presented higher values. (author)

  17. Elemental analysis of combustion products by neutron activation

    International Nuclear Information System (INIS)

    Heft, R.E.; Koszykowski, R.F.

    1980-01-01

    This paper gives a brief description of the neutron activation analysis method, which is being used to determine the elemental profile of combustion products from coal-fired power plants, oil shale retorting, and underground coal gasification

  18. Trace element analysis: a diagnostic tool

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Cheema, M.N.

    1976-09-01

    The human mody continuously assimilates a variety of elements from the environment, and the concentration of these elements in the blood is regulated by means of various homeostatic mechanisms. Some of the elements, though present in very small amounts, have highly specialized functions in initiating many biochemical reactions. These elements, known as essential trace elements, are closely related to human diseases since their deficiency or excess induces physiological changes. Many diseases such as hypertension, atherosclerosis, diabetes, etc., are related to an imbalance in trace element. The measurement of trace elements in body fluids and tissues can, therefore, be effectively employed for diagnostic tests

  19. [Content of mineral elements of Gastrodia elata by principal components analysis].

    Science.gov (United States)

    Li, Jin-ling; Zhao, Zhi; Liu, Hong-chang; Luo, Chun-li; Huang, Ming-jin; Luo, Fu-lai; Wang, Hua-lei

    2015-03-01

    To study the content of mineral elements and the principal components in Gastrodia elata. Mineral elements were determined by ICP and the data was analyzed by SPSS. K element has the highest content-and the average content was 15.31 g x kg(-1). The average content of N element was 8.99 g x kg(-1), followed by K element. The coefficient of variation of K and N was small, but the Mn was the biggest with 51.39%. The highly significant positive correlation was found among N, P and K . Three principal components were selected by principal components analysis to evaluate the quality of G. elata. P, B, N, K, Cu, Mn, Fe and Mg were the characteristic elements of G. elata. The content of K and N elements was higher and relatively stable. The variation of Mn content was biggest. The quality of G. elata in Guizhou and Yunnan was better from the perspective of mineral elements.

  20. Assessment of non-linear analysis finite element program (NONSAP) for inelastic analysis

    International Nuclear Information System (INIS)

    Chang, T.Y.; Prachuktam, S.; Reich, M.

    1976-11-01

    An assessment on a nonlinear structural analysis finite element program called NONSAP is given with respect to its inelastic analysis capability for pressure vessels and components. The assessment was made from the review of its theoretical basis and bench mark problem runs. It was found that NONSAP has only limited capability for inelastic analysis. However, the program was written flexible enough that it can be easily extended or modified to suit the user's need. Moreover, some of the numerical difficulties in using NONSAP are pointed out

  1. Advanced neutron source reactor conceptual safety analysis report, three-element-core design: Chapter 15, accident analysis

    International Nuclear Information System (INIS)

    Chen, N.C.J.; Wendel, M.W.; Yoder, G.L.; Harrington, R.M.

    1996-02-01

    In order to utilize reduced enrichment fuel, the three-element-core design for the Advanced Neutron Source has been proposed. The proposed core configuration consists of inner, middle, and outer elements, with the middle element offset axially beneath the inner and outer elements, which are axially aligned. The three-element-core RELAP5 model assumes that the reactor hardware is changed only within the core region, so that the loop piping, heat exchangers, and pumps remain as assumed for the two-element-core configuration. To assess the impact of changes in the core region configuration and the thermal-hydraulic steady-state conditions, the safety analysis has been updated. This report gives the safety margins for the loss-of-off-site power and pressure-boundary fault accidents based on the RELAP5 results. AU margins are greater for the three-element-core simulations than those calculated for the two-element core

  2. Electromagnetic analysis of locking device for SMART control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hyung; Kim, J. I.; Kim, J. H. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-09-01

    A numerical electromagnetic analysis was performed for the control rod locking device which is installed in the control element drive mechanism of integral reactor, SMART. A plunger model for the electromagnetic analysis of the locking device was developed and theoretical bases for the model were established. Design parameters related to plunger pushing force were identified, and the optimum design point was determined by analysing the trend of the plunger pushing force with finite element method. 8 refs., 22 figs., 2 tabs. (Author)

  3. Costs of Quality: Exploratory Analysis of Hidden Elements and Prioritization using Analytic Hierarchy Process

    Directory of Open Access Journals (Sweden)

    Sailaja A

    2015-02-01

    Full Text Available Cost of Quality analysis is emerged as an effective tool for the industrial managers for pinpointing the deficiencies in the system as well as for identifying the improvement areas by highlighting the cost reduction opportunities. However , this analysis will be fully effective only if it is further extended to identify the cost incurred in ensuring quality in all areas of the supply chain including the hidden costs and costs of missed out opportunities. Most of the hidden elements of quality costs are difficult to track and not accounted by the traditional accounting tools. An exploratory analysis is made in this research to identify the hidden elements of quality costs in manufacturing industry. Further, the identified cost elements are classified into various groups for better analysis and, finally, prioritized to identify the vital few among them. Analytic Hierarchy Process (AHP technique which is one of the most popular Multi Criteria Decision Method (MCDM and Pareto analysis were used in this study for prioritizing the hidden quality cost elements based on their degree of impact on overall cost of quality. By this analysis, the key cost elements which are to be addressed to reduce the overall cost of quality are identified.

  4. In vivo monitoring of heavy metals in man: cadmium and mercury

    International Nuclear Information System (INIS)

    Ellis, K.J.; Vartsky, D.; Cohn, S.H.

    1982-01-01

    Direct in vivo measurements of selected heavy metals is possible by nuclear analytical techniques. In particular, cadmium and mercury are retained in the body in sufficient quantities for their detection by neutron activation analysis. Autopsy data on cadmium of adult male non-smokers living in the US indicates an average body burden of 30 mg by age 50. The distribution of cadmium in the body, however, is nonuniform, approximately 50% being located in the kidneys and liver. The increased concentration of cadmium within these organs has made possible the direct in vivo measurements of this metal by prompt-gamma neutron activation analysis (PGNAA). At present, in vivo determinations of mercury have been performed on phantoms only. These in vivo techniques provide a unique method of obtaining accurate organ burden data in humans that can be related to the toxicological effects of these metals

  5. Radiochemical neutron activation analysis for trace elements evaluation of human milk

    International Nuclear Information System (INIS)

    Gill, K.P.; Zaidi, J.H.; Ahmad, S.

    2003-01-01

    The principal objective pursued in this study is to establish the base-line data on the status of elemental composition in human milk from Pakistani subjects of Rawalpindi/Islamabad area. Radiochemical neutron activation analysis (RNAA) methodology was developed and successfully employed to determine the concentration of 18 minor and trace elements (essential, toxic and nonessential) in human milk. This methodology has significantly improved the detection limits of most of these elements due to suppression of Compton background. The data provide the base-line values of these elements in human milk of low- and medium-income group subjects of the region. The results obtained show good compatibility with the data reported by the WHO on elemental composition of human milk from different geological regions. (orig.)

  6. Functional analysis of Pro-inflammatory properties within the cerebrospinal fluid after subarachnoid hemorrhage in vivo and in vitro

    Directory of Open Access Journals (Sweden)

    Schneider Ulf C

    2012-02-01

    Full Text Available Abstract Background To functionally characterize pro-inflammatory and vasoconstrictive properties of cerebrospinal fluid after aneurysmal subarachnoid hemorrhage (SAH in vivo and in vitro. Methods The cerebrospinal fluid (CSF of 10 patients suffering from SAH was applied to the transparent skinfold chamber model in male NMRI mice which allows for in vivo analysis of the microcirculatory response to a superfusat. Microvascular diameter changes were quantified and the numbers of rolling and sticking leukocytes were documented using intravital multifluorescence imaging techniques. Furthermore, the pro-inflammatory properties of CSF were assessed in vitro using a monocyte transendothelial migration assay. Results CSF superfusion started to induce significant vasoconstriction on days 4 and 6 after SAH. In parallel, CSF superfusion induced a microvascular leukocyte recruitment, with a significant number of leukocytes rolling (day 6 and sticking (days 2-4 to the endothelium. CSF of patients presenting with cerebral edema induced breakdown of blood vessel integrity in our assay as evidenced by fluorescent marker extravasation. In accordance with leukocyte activation in vivo, significantly higher in vitro monocyte migration rates were found after SAH. Conclusion We functionally characterized inflammatory and vasoactive properties of patients' CSF after SAH in vivo and in vitro. This pro-inflammatory milieu in the subarachnoid space might play a pivotal role in the pathophysiology of early and delayed brain injury as well as vasospasm development following SAH.

  7. Finite element analysis of nonlinear creeping flows

    International Nuclear Information System (INIS)

    Loula, A.F.D.; Guerreiro, J.N.C.

    1988-12-01

    Steady-state creep problems with monotone constitutive laws are studied. Finite element approximations are constructed based on mixed Petrov-Galerkin formulations for constrained problems. Stability, convergence and a priori error estimates are proved for equal-order discontinuous stress and continuous velocity interpolations. Numerical results are presented confirming the rates of convergence predicted in the analysis and the good performance of this formulation. (author) [pt

  8. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  9. Location analysis for the estrogen receptor-α reveals binding to diverse ERE sequences and widespread binding within repetitive DNA elements

    Science.gov (United States)

    Mason, Christopher E.; Shu, Feng-Jue; Wang, Cheng; Session, Ryan M.; Kallen, Roland G.; Sidell, Neil; Yu, Tianwei; Liu, Mei Hui; Cheung, Edwin; Kallen, Caleb B.

    2010-01-01

    Location analysis for estrogen receptor-α (ERα)-bound cis-regulatory elements was determined in MCF7 cells using chromatin immunoprecipitation (ChIP)-on-chip. Here, we present the estrogen response element (ERE) sequences that were identified at ERα-bound loci and quantify the incidence of ERE sequences under two stringencies of detection: ERE sequence. We demonstrate that ∼50% of all ERα-bound loci do not have a discernable ERE and show that most ERα-bound EREs are not perfect consensus EREs. Approximately one-third of all ERα-bound ERE sequences reside within repetitive DNA sequences, most commonly of the AluS family. In addition, the 3-bp spacer between the inverted ERE half-sites, rather than being random nucleotides, is C(A/T)G-enriched at bona fide receptor targets. Diverse ERα-bound loci were validated using electrophoretic mobility shift assay and ChIP-polymerase chain reaction (PCR). The functional significance of receptor-bound loci was demonstrated using luciferase reporter assays which proved that repetitive element ERE sequences contribute to enhancer function. ChIP-PCR demonstrated estrogen-dependent recruitment of the coactivator SRC3 to these loci in vivo. Our data demonstrate that ERα binds to widely variant EREs with less sequence specificity than had previously been suspected and that binding at repetitive and nonrepetitive genomic targets is favored by specific trinucleotide spacers. PMID:20047966

  10. Location analysis for the estrogen receptor-alpha reveals binding to diverse ERE sequences and widespread binding within repetitive DNA elements.

    Science.gov (United States)

    Mason, Christopher E; Shu, Feng-Jue; Wang, Cheng; Session, Ryan M; Kallen, Roland G; Sidell, Neil; Yu, Tianwei; Liu, Mei Hui; Cheung, Edwin; Kallen, Caleb B

    2010-04-01

    Location analysis for estrogen receptor-alpha (ERalpha)-bound cis-regulatory elements was determined in MCF7 cells using chromatin immunoprecipitation (ChIP)-on-chip. Here, we present the estrogen response element (ERE) sequences that were identified at ERalpha-bound loci and quantify the incidence of ERE sequences under two stringencies of detection: ERE sequence. We demonstrate that approximately 50% of all ERalpha-bound loci do not have a discernable ERE and show that most ERalpha-bound EREs are not perfect consensus EREs. Approximately one-third of all ERalpha-bound ERE sequences reside within repetitive DNA sequences, most commonly of the AluS family. In addition, the 3-bp spacer between the inverted ERE half-sites, rather than being random nucleotides, is C(A/T)G-enriched at bona fide receptor targets. Diverse ERalpha-bound loci were validated using electrophoretic mobility shift assay and ChIP-polymerase chain reaction (PCR). The functional significance of receptor-bound loci was demonstrated using luciferase reporter assays which proved that repetitive element ERE sequences contribute to enhancer function. ChIP-PCR demonstrated estrogen-dependent recruitment of the coactivator SRC3 to these loci in vivo. Our data demonstrate that ERalpha binds to widely variant EREs with less sequence specificity than had previously been suspected and that binding at repetitive and nonrepetitive genomic targets is favored by specific trinucleotide spacers.

  11. Digital Radiography for Determination of Primary Tooth Length: In Vivo and Ex Vivo Studies

    Directory of Open Access Journals (Sweden)

    Maria D. Basso

    2015-01-01

    Full Text Available Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm. The apparent tooth length (APTL was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0, whereas the actual tooth length (ACTL was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed (P≤0.48 between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

  12. Failure analysis for WWER-fuel elements

    International Nuclear Information System (INIS)

    Boehmert, J.; Huettig, W.

    1986-10-01

    If the fuel defect rate proves significantly high, failure analysis has to be performed in order to trace down the defect causes, to implement corrective actions, and to take measures of failure prevention. Such analyses are work-consuming and very skill-demanding technical tasks, which require examination methods and devices excellently developed and a rich stock of experience in evaluation of features of damage. For that this work specifies the procedure of failure analyses in detail. Moreover prerequisites and experimental equipment for the investigation of WWER-type fuel elements are described. (author)

  13. PIXE trace element analysis of a selection of wines

    International Nuclear Information System (INIS)

    Houdayer, A.; Hinrichsen, P.F.; Martin, J.P.; Belhadfa, A.

    1987-01-01

    The University of Montreal EN Tandem accelerator and a Si (Li) X-ray detector were used for a PIXE (Proton Induced X-ray emission) trace element analysis of a selection of wines. Quantitative measurements of the concentrations of the sixteen trace elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Co, Cu, Zn, and Br were made. To optimize the sensitivity, spectra were recorded at 1.0 MeV proton energy for elements with Z 19. The absolute concentrations of the trace elements were determined by doping the samples of wine with 1000 ppm of vanadium for the 1.0 MeV bombardments, and 1000 ppm of yttrium for the 3.0 MeV irradiations. The targets were prepared by depositing a few microliters of the wine onto a Nuclepore filter

  14. Simultaneous multi-element determination in different seed samples of Dodonaea viscosa hopseed using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, Fatma H.; El-Amir, Mahmoud A.; Mostafa, Mohamed; Ramadan, Hala E.; Rashad, Ghada M.

    2016-01-01

    Instrumental neutron activation analysis technique (INAA) was applied for nondestructive multi-element analysis of seed samples of the plant Dodonaea viscosa hopseed. This plant is distributed all over Egypt, because of its suitable properties. The samples were collected from some bushes grown at different sites in some governorates, in July of each year during the period from 2004 to 2011. The determined elements are: Co, Cs, Eu, Fe, Hg, Ni, Rb, Sc, Se, Sr and Zn, under the chosen irradiation and cooling times. The content of some elements has been compared with data obtained from previous work on analysis of various kinds of seeds. The influence of some parameters on the determined elemental content is discussed. Standard reference materials IAEA-155 and IAEA-V-10 were used to assure quality control, accuracy and precision of the technique.

  15. Simultaneous multi-element determination in different seed samples of Dodonaea viscosa hopseed using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, Fatma H.; El-Amir, Mahmoud A.; Mostafa, Mohamed; Ramadan, Hala E.; Rashad, Ghada M. [Atomic Energy Authority, Cairo (Egypt). Hot Lab. Center

    2016-07-01

    Instrumental neutron activation analysis technique (INAA) was applied for nondestructive multi-element analysis of seed samples of the plant Dodonaea viscosa hopseed. This plant is distributed all over Egypt, because of its suitable properties. The samples were collected from some bushes grown at different sites in some governorates, in July of each year during the period from 2004 to 2011. The determined elements are: Co, Cs, Eu, Fe, Hg, Ni, Rb, Sc, Se, Sr and Zn, under the chosen irradiation and cooling times. The content of some elements has been compared with data obtained from previous work on analysis of various kinds of seeds. The influence of some parameters on the determined elemental content is discussed. Standard reference materials IAEA-155 and IAEA-V-10 were used to assure quality control, accuracy and precision of the technique.

  16. Facilitating in vivo tumor localization by principal component analysis based on dynamic fluorescence molecular imaging

    Science.gov (United States)

    Gao, Yang; Chen, Maomao; Wu, Junyu; Zhou, Yuan; Cai, Chuangjian; Wang, Daliang; Luo, Jianwen

    2017-09-01

    Fluorescence molecular imaging has been used to target tumors in mice with xenograft tumors. However, tumor imaging is largely distorted by the aggregation of fluorescent probes in the liver. A principal component analysis (PCA)-based strategy was applied on the in vivo dynamic fluorescence imaging results of three mice with xenograft tumors to facilitate tumor imaging, with the help of a tumor-specific fluorescent probe. Tumor-relevant features were extracted from the original images by PCA and represented by the principal component (PC) maps. The second principal component (PC2) map represented the tumor-related features, and the first principal component (PC1) map retained the original pharmacokinetic profiles, especially of the liver. The distribution patterns of the PC2 map of the tumor-bearing mice were in good agreement with the actual tumor location. The tumor-to-liver ratio and contrast-to-noise ratio were significantly higher on the PC2 map than on the original images, thus distinguishing the tumor from its nearby fluorescence noise of liver. The results suggest that the PC2 map could serve as a bioimaging marker to facilitate in vivo tumor localization, and dynamic fluorescence molecular imaging with PCA could be a valuable tool for future studies of in vivo tumor metabolism and progression.

  17. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1964-06-15

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected.

  18. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1964-06-01

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected

  19. Provenance Establishment of Stingless Bee Honey Using Multi-element Analysis in Combination with Chemometrics Techniques.

    Science.gov (United States)

    Shadan, Aidil Fahmi; Mahat, Naji A; Wan Ibrahim, Wan Aini; Ariffin, Zaiton; Ismail, Dzulkiflee

    2018-01-01

    As consumption of stingless bee honey has been gaining popularity in many countries including Malaysia, ability to identify accurately its geographical origin proves pertinent for investigating fraudulent activities for consumer protection. Because a chemical signature can be location-specific, multi-element distribution patterns may prove useful for provenancing such product. Using the inductively coupled-plasma optical emission spectrometer as well as principal component analysis (PCA) and linear discriminant analysis (LDA), the distributions of multi-elements in stingless bee honey collected at four different geographical locations (North, West, East, and South) in Johor, Malaysia, were investigated. While cross-validation using PCA demonstrated 87.0% correct classification rate, the same was improved (96.2%) with the use of LDA, indicating that discrimination was possible for the different geographical regions. Therefore, utilization of multi-element analysis coupled with chemometrics techniques for assigning the provenance of stingless bee honeys for forensic applications is supported. © 2017 American Academy of Forensic Sciences.

  20. The nonlinear finite element analysis program NUCAS (NUclear Containment Analysis System) for reinforced concrete containment building

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Jin; Lee, Hong Pyo; Seo, Jeong Moon [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    The maim goal of this research is to develop a nonlinear finite element analysis program NUCAS to accurately predict global and local failure modes of containment building subjected to internal pressure. In this report, we describe the techniques we developed throught this research. An adequate model to the analysis of containment building such as microscopic material model is adopted and it applied into the development Reissner-Mindlin degenerated shell element. To avoid finite element deficiencies, the substitute strains based on the assumed strain method is used in the shell formulation. Arc-length control method is also adopted to fully trace the peak load-displacement path due to crack formation. In addition, a benchmark test suite is developed to investigate the performance of NUCAS and proposed as the future benchmark tests for nonlinear analysis of reinforced concrete. Finally, the input format of NUCAS and the examples of input/output file are described. 39 refs., 65 figs., 8 tabs. (Author)

  1. Theoretical basis for a transient thermal elastic-plastic stress analysis of nuclear reactor fuel elements

    International Nuclear Information System (INIS)

    Hsu, T.R.; Bertels, A.W.M.; Banerjee, S.; Harrison, W.C.

    1976-07-01

    This report presents the theoretical basis for a transient thermal elastic-plastic stress analysis of a nuclear reactor fuel element subject to severe transient thermo-mechanical loading. A finite element formulation is used for both the non-linear stress analysis and thermal analysis. These two major components are linked together to form an integrated program capable of predicting fuel element transient behaviour in two dimensions. Specific case studies are presented to illustrate capabilities of the analysis. (author)

  2. Space-resolved analysis of trace elements in fresh vegetables using ultraviolet nanosecond laser-induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Juve, Vincent; Portelli, Richard; Boueri, Myriam; Baudelet, Matthieu; Yu Jin

    2008-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to analyze trace elements contained in fresh vegetables. A quadrupled Nd:YAG laser is used in the experiments for ablation. Analyzed samples come from local markets and represent frequently consumed vegetables. For a typical root vegetable, such as potato, spectral analysis of the plasma emission reveals more than 400 lines emitted by 27 elements and 2 molecules, C 2 and CN. Among these species, one can find trace as well as ultra-trace elements. A space-resolved analysis of several trace elements with strong emissions is then applied to typical root, stem and fruit vegetables. The results from this study demonstrate the potential of an interesting tool for botanical and agricultural studies as well for food quality/safety and environment pollution assessment and control

  3. Interfering elements in activation analysis. Study of instrumental analysis possibilities for the groups: Sc-Zn, Hg-Se and As-Sb-Br

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.; Atalla, L.T.

    1979-01-01

    The determination of the elements present in the groups Sc-Zn, Hg-Se and As-Sb-Br represents a classical problem in thermal neutron activation analysis, since the energy values of the gamma-ray photopeaks of the radioisotopes of these elements formed by thermal neutron activation are very closely located in the spectrum. A study is presented of the possibility of simultaneous instrumental determination of these elements by means of the spectrum stripping technique. For this purpose, artificial mixtures of the interfering elements, in varying proportions, were prepared. Radiochemical separations procedures for the above mentioned elements were also studied by means of tracers. (Author) [pt

  4. In-situ elemental analysis of coal by neutron activation

    International Nuclear Information System (INIS)

    Mikesell, J.L.; Senftle, F.E.; Tanner, A.B.

    1986-01-01

    The U.S. Geological Survey (USGS) has worked to develop neutron techniques for the borehole measurement of the elemental composition of ores since 1969, and first demonstrated a borehole ultimate analysis of coal in 1977. Borehole measurements such as these permit real-time evaluation of coal quality without the expense of coring or the delays associated with laboratory analyses. Two technological innovations make such measurements possible: the availability, from Savannah River Operations Office, DOE, of small californium-252 (/sup 252/Cf) fission neutron sources, and the development, by USGS and Princeton Gamma-Techn, of the melting-cryogen-cooled high-purity germanium borehole gamma-ray detector. A technique of relating mass fractions to measured gamma-ray intensities, which eliminates the need for detailed knowledge of the geometry of the neutron distribution, is used to calculate elemental compositions without resorting to the test pits or computer borehole modeling. In coal, all of the major constituents (C, H, N, S, Si, Al, Fe, Ti) except oxygen can be determined quantitatively by thermal neutron capture gamma-ray spectroscopy

  5. Analysis of oil shale and oil shale products for certain minor elements

    International Nuclear Information System (INIS)

    Dickman, P.T.; Purdy, M.; Doerges, J.E.; Ryan, V.A.; Poulson, R.E.

    1977-01-01

    The University of Wyoming was contracted by the Department of Energy's Laramie Energy Research Center (LERC) to develop rapid, inexpensive, and simple methods of quantitative and qualitative elemental analysis for products used and generated in the simulated in-situ retorting of oil shale. Alpha particle spectrometry was used to determine the radioisotope content of the aqueous retort products. Alpha particles are mono-energetic and the spectrometry method employed had very low background levels (1 count per 2000 seconds). These factors allow for both the quantitative and qualitative analysis of natural radioisotopes at the 1 ppm level. Sample preparation does not require any chemical treatment. Energy dispersive x-ray fluorescence (XRF) was used for the multi-element analysis of the retort products. The XRF, integrated with a mini-computer, allows rapid analysis of several elements in multiple samples. XRF samples require minimal amounts of preparation and analytical results are highly reproducible. This paper presents the methods developed and preliminary analytical results from oil shale by-products. Results from the analysis of oil shale rocks are not yet ready for presentation

  6. Biological reference materials and analysis of toxic elements

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, R; Sukumar, A

    1988-12-01

    Biological monitoring of toxic metal pollution in the environment requires quality control analysis with use of standard reference materials. A variety of biological tissues are increasingly used for analysis of element bioaccumulation, but the available Certified Reference Materials (CRMs) are insufficient. An attempt is made to review the studies made using biological reference materials for animal and human tissues. The need to have inter-laboratory studies and CRM in the field of biological monitoring of toxic metals is also discussed.

  7. Finite element analysis of residual stress in plasma-sprayed ceramic

    International Nuclear Information System (INIS)

    Mullen, R.L.; Hendricks, R.C.; McDonald, G.

    1985-01-01

    Residual stress in a ZrO 2 -Y 2 O 3 ceramic coating resulting from the plasma spraying operation is calculated. The calculations were done using the finite element method. Both thermal and mechanical analysis were performed. The resulting residual stress field was compared to the measurements obtained by Hendricks and McDonald. Reasonable agreement between the predicted and measured moment occurred. However, the resulting stress field is not in pure bending

  8. Electromagnetic and thermal analysis of electromagnet for SMART control element drive mechanism

    International Nuclear Information System (INIS)

    Huh, H.; Kim, J. H.; Park, J. S.; Kim, Y. W.; Kim, J. I.

    1999-01-01

    A numerical electromagnetic and thermal analysis was performed for the electromagnet which is installed in the control element drive mechanism(CEDM) of the integral reactor SMART. A model for the electromagnetic analysis of the electromagnet was developed and theoretical bases for the model were established. Design parameters related to thrust force were identified, and the optimum design point was determined by analyzing the trend of the magnetic saturation with finite element method. Also It is important that the temperature of the electomagnet windings be maintained within the allowable limit of the insulation, since the electromagnet of CEDM is always supplied with current during the reactor operation. So the thermal analysis of the winding insulation which is composed of polyimide and air were performed by finite element method. The electromagnetic and thermal properties obtained here will be used as input for the optimization analysis of the electromagnet

  9. PHARMACOPOEIA METHODS FOR ELEMENTAL ANALYSIS OF MEDICINES: A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Tetiana M. Derkach

    2018-01-01

    Full Text Available The article is devoted to the problem of quality assurance of medicinal products, namely the determination of elemental impurity concentration compared to permitted daily exposures for and the correct choice analytical methods that are adequate to the formulated tasks. The paper goal is to compare characteristics of four analytical methods recommended by the Pharmacopoeia of various countries to control the content of elemental impurities in medicines, including medicinal plant raw materials and herbal medicines. Both advantages and disadvantages were described for atomic absorption spectroscopy with various atomising techniques, as well as atomic emission spectroscopy and mass spectrometry with inductively coupled plasma. The choice of the most rational analysis method depends on a research task and is reasoned from the viewpoint of analytical objectives, possible complications, performance attributes, and economic considerations. The methods of ICP-MS and GFAAS were shown to provide the greatest potential for determining the low and ultra-low concentrations of chemical elements in medicinal plants and herbal medicinal products. The other two methods, FAAS and ICP-AES, are limited to the analysis of the main essential elements and the largest impurities. The ICP-MS is the most efficient method for determining ultra-low concentrations. However, the interference of mass peaks is typical for ICP-MS. It is formed not only by impurities but also by polyatomic ions with the participation of argon, as well as atoms of gases from the air (C, N and O or matrices (O, N, H, P, S and Cl. Therefore, a correct sample preparation, which guarantees minimisation of impurity contamination and loss of analytes becomes the most crucial stage of analytical applications of ICP-MS. The detections limits for some chemical elements, which content is regulated in modern Pharmacopoeia, were estimated for each method and analysis conditions of medicinal plant raw

  10. Trace-Element Analysis by Use of PIXE Technique on Agricultural Products

    Science.gov (United States)

    Takagi, A.; Yokoyama, R.; Makisaka, K.; Kisamori, K.; Kuwada, Y.; Nishimura, D.; Matsumiya, R.; Fujita, Y.; Mihara, M.; Matsuta, K.; Fukuda, M.

    2009-10-01

    In order to examine whether a trace-element analysis by PIXE (Particle Induced X-ray Emission) gives a clue to identify production area of agricultural products, we carried out a study on soy beans as an example. In the present study, a proton beam at the energy of 2.3MeV was provided by Van de Graaff accelerator at Osaka University. We used a Ge detector with Be window to measure X-ray spectra. We prepared sample soy beans from China, Thailand, Taiwan, and 7 different areas in Japan. As a result of PIXE analysis, 5 elements, potassium, iron, zinc, arsenic and rubidium, have been identified. There are clear differences in relative amount of trace-elements between samples from different international regions. Chinese beans contain much more Rb than the others, while there are significant differences in Fe and Zn between beans of Thailand and Taiwan. There are relatively smaller differences among Japanese beans. This result shows that trace-elements bring us some practical information of the region where the product grown.

  11. Studies on elemental analysis of widely consumed traditional herbs in Libya by ko instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Abugassa, I. O.; Abunawael, M. E.

    2012-12-01

    Herbs are accepted as an alternative medicine for specific treatment of illness of among different ethnic groups worldwide. It is vital to know the contents of these herbs used in Libya were analysed by k-0 instrumental neutron activation analysis. A total of 32 trace and major elements (Ag, As, Au, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, Hg, K, La, Mo, Na, Nd, Rb, Sb, Sc, Se, Sm, Sr, Tb, Th, Tm, U, Yb and Zn) were determined. The concentration of elements varied depending on the origin of the herb. The study showed that the toxic elements found in the samples were below the levels prescribed by health regulations. The method was justified by analyzing two SRM. All the results are in good agreement with the certified values. (Author)

  12. Correction for interelement effect in X-Ray fluorescence analysis of trace elements in geological materials

    International Nuclear Information System (INIS)

    El-Behay, A.Z.; Attawiya, M.Y.; Khattab, F.M.

    1984-01-01

    In a trial to obtain accurate results from X-ray fluorescence technique for the analysis of trace elements in geological materials, two corrections were used for the obtained data, namely, correction for the observed x-ray intensities for absorption and/or enhancement effects due to the presence of other elements in the system and correction for spectral deconvolution to account for the overlapping lines. Significant improvement in the precision and accuracy was obtained and evaluated

  13. A new discrete Kirchhoff-Mindlin element based on Mindlin-Reissner plate theory and assumed shear strain fields. I - An extended DKT element for thick-plate bending analysis. II - An extended DKQ element for thick-plate bending analysis

    Science.gov (United States)

    Katili, Irwan

    1993-06-01

    A new three-node nine-degree-of-freedom triangular plate bending element is proposed which is valid for the analysis of both thick and thin plates. The element, called the discrete Kirchhoff-Mindlin triangle (DKMT), has a proper rank, passes the patch test for thin and thick plates in an arbitrary mesh, and is free of shear locking. As an extension of the DKMT element, a four-node element with 3 degrees of freedom per node is developed. The element, referred to as DKMQ (discrete Kirchhoff-Mindlin quadrilateral) is found to provide good results for both thin and thick plates without any compatibility problems.

  14. PLANS; a finite element program for nonlinear analysis of structures. Volume 2: User's manual

    Science.gov (United States)

    Pifko, A.; Armen, H., Jr.; Levy, A.; Levine, H.

    1977-01-01

    The PLANS system, rather than being one comprehensive computer program, is a collection of finite element programs used for the nonlinear analysis of structures. This collection of programs evolved and is based on the organizational philosophy in which classes of analyses are treated individually based on the physical problem class to be analyzed. Each of the independent finite element computer programs of PLANS, with an associated element library, can be individually loaded and used to solve the problem class of interest. A number of programs have been developed for material nonlinear behavior alone and for combined geometric and material nonlinear behavior. The usage, capabilities, and element libraries of the current programs include: (1) plastic analysis of built-up structures where bending and membrane effects are significant, (2) three dimensional elastic-plastic analysis, (3) plastic analysis of bodies of revolution, and (4) material and geometric nonlinear analysis of built-up structures.

  15. In vitro-in vivo correlation in skin permeation.

    Science.gov (United States)

    Mohammed, D; Matts, P J; Hadgraft, J; Lane, M E

    2014-02-01

    In vitro skin permeation studies have been used extensively in the development and optimisation of delivery of actives in vivo. However, there are few reported correlations of such in vitro studies with in vivo data. The aim of this study was to investigate the skin permeation of a model active, niacinamide, both in vitro and in vivo. Conventional diffusion cell studies were conducted in human skin to determine niacinamide permeation from a range of vehicles which included dimethyl isosorbide (DMI), propylene glycol (PG), propylene glycol monolaurate (PGML), N-methyl 2-pyrrolidone (NMP), Miglyol 812N® (MG), and mineral oil (MO). Single, binary or ternary systems were examined. The same vehicles were subsequently examined to investigate niacinamide delivery in vivo. For this proof-of-concept study one donor was used for the in vitro studies and one volunteer for the in vivo investigations to minimise biovariability. Analysis of in vitro samples was conducted using HPLC and in vivo uptake of niacinamide was evaluated using Confocal Raman spectroscopy (CRS). The amount of niacinamide permeated through skin in vitro was linearly proportional to the intensity of the niacinamide signal determined in the stratum corneum in vivo. A good correlation was observed between the signal intensities of selected vehicles and niacinamide signal intensity. The findings provide further support for the use of CRS to monitor drug delivery into and across the skin. In addition, the results highlight the critical role of the vehicle and its disposition in skin for effective dermal delivery.

  16. Neutron activation analysis of rare earths and some other elements in material of geochemical interest

    International Nuclear Information System (INIS)

    Brunfelt, A.O.

    1975-01-01

    ngle-element methods for the determination by neutron activation analysis of antimony, chromium, phosphorus, selenium and silver in international geochemical standard rocks, and the determination of rare earth elements i in standard rocks and apatites are described and discussed in twelve previously published papers, and in an eighteen page summary. Chemical separationtechniques are also discussed and the results are compared with previously obtained results with the same standard rocks. The accuracy of neutron activation analysis is discussed in comparison with isotope dilution mass spectroscopy, atomic absorption, gas chromatography and spark source mass spectrometry. (JIW)

  17. Trace elemental analysis of carcinoma kidney and stomach by PIXE method

    International Nuclear Information System (INIS)

    Reddy, S. Bhuloka; John Charles, M.; Naga Raju, G.J.; Vijayan, V.; Seetharami Reddy, B.; Ravi Kumar, M.; Sundareswar, B.

    2003-01-01

    Trace elemental analysis was carried out in the biological samples of carcinoma kidney and stomach using particle induced X-ray emission technique. A 2 MeV proton beam was employed to excite the samples. From the present results, the levels of elements K, Ca, Fe, Ni and Se are lower and those of the elements Ti, Co, Zn, As and Cd are higher in the cancer tissue of kidney than those observed in the normal tissue. In the case of stomach, the concentrations of elements Cl, K, Ca, Ti, Mn, Fe, Co, Cu and Zn are lower while concentrations of elements Cr, Ni, As and Br are higher in the cancer tissue of stomach than those observed in the normal tissue. The observed deficiency or excess of certain elements is correlated to carcinogenesis of that organ. The present results of carcinoma stomach support the previous observations that nickel and chromium are carcinogenic agents. The low levels of selenium observed in the carcinoma tissue of kidney and the low levels of manganese observed in the carcinoma tissue of stomach support the view that selenium and manganese inhibit the growth of cancer in kidney and stomach respectively. The observed high levels of zinc in the cancer tissue of kidney suggest that zinc is involved in the tumor growth and development of neoplastic transformation in kidney while the observed low levels of zinc in the carcinoma tissue of stomach suggest that zinc inhibits the growth of cancer in this organ. For correctly assessing the role played by the trace elements in initiating, promoting or inhibiting cancer in various organs, there is a need for acquisition of more data by trace elemental analysis from several investigations of this type undertaken in different regions

  18. Finite element analysis of cylindrical pressure vessels having a misalignment in a circumferential joint

    International Nuclear Information System (INIS)

    Aseer Brabin, T.; Christopher, T.; Nageswara Rao, B.

    2010-01-01

    Finite element analysis (FEA) has been carried out to obtain the elastic stress distribution at cylinder-to-cylinder junction in pressurized shell structures that have applications in space - vehicle design. To validate the finite element modeling and analysis results, three joint configurations, (viz., unfilleted butt joint with equal thickness, unfilleted butt joint with unequal thickness and filleted butt joint with equal thickness) having test results in open literature were considered. The peak stress values for these configurations obtained from FEA are close to that of test results. The peak stress value is found to reduce due to filleted butt joint as expected and also confirmed through test results.

  19. Intravital multiphoton tomography as a novel tool for non-invasive in vivo analysis of human skin affected with atopic dermatitis

    Science.gov (United States)

    Huck, Volker; Gorzelanny, Christian; Thomas, Kai; Niemeyer, Verena; Luger, Thomas A.; König, Karsten; Schneider, Stefan W.

    2010-02-01

    Atopic Dermatitis (AD) is an inflammatory disease of human skin. Its pathogenesis is still unknown; however, dysfunctions of the epidermal barrier and the immune response are regarded as key factors for the development of AD. In our study we applied intravital multiphoton tomography (5D-IVT), equipped with a spectral-FLIM module for in-vivo and ex-vivo analysis of human skin affected with AD. In addition to the morphologic skin analysis, FLIM technology gain access to the metabolic status of the epidermal cells referring to the NADH specific fluorescence lifetime. We evaluated a characteristic 5D-IVT skin pattern of AD in comparison to histological sections and detected a correlation with the disease activity measured by SCORAD. FLIM analysis revealed a shift of the mean fluorescence lifetime (taum) of NADH, indicating an altered metabolic activity. Within an ex-vivo approach we have investigated cryo-sections of human skin with or without barrier defects. Spectral-FLIM allows the detection of autofluorescent signals that reflect the pathophysiological conditions of the defect skin barrier. In our study the taum value was shown to be different between healthy and affected skin. Application of the 5D-IVT allows non-invasive in-vivo imaging of human skin with a penetration depth of 150 μm. We could show that affected skin could be distinguished from healthy skin by morphological criteria, by FLIM and by spectral-FLIM. Further studies will evaluate the application of the 5D-IVT technology as a diagnostic tool and to monitor the therapeutic efficacy.

  20. Complex of the equipment for instrumental element analysis

    International Nuclear Information System (INIS)

    Borisov, G.I.; Komkov, M.M.; Kuz'michev, V.A.

    1986-01-01

    Complex of the equipment for instrumental element analysis at the IR-8 reactor is designed, fabricated and taken into operation. The complex is provided with a multichannel system of vacuum pneumatic transport with radiation positions in the reactor horizontal tangential channel for neutron-activation analysis by short-lived isotopes; specialized dry vertical channels in a beryllium reflector of the reactor and remote system of radioactive sample replacement for neutron-activation analysis by long-lived isotopes; a specialized horizontal tangential channel for neutron beam extraction by means of a beryllium converter and remote device for studied sample replacement under radiation and measurement of prompt γ-radiation for neutron-radiation analysis; a measuring center using minicomputers for experimental data accumulation and processing and analysis control