WorldWideScience

Sample records for in-stent restenosis meta-analysis

  1. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  2. Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis

    International Nuclear Information System (INIS)

    Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo

    2005-01-01

    Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm

  3. Coated stents to prevent restenosis in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2005-11-01

    Full Text Available Background: In-stent-restenosis (ISR is considered to be an essential limiting factor of stenting in coronary heart disease (CHD. The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. Objectives: The present analysis addresses the questions on medical effectiveness and cost-effectiveness of the use of various coated stent types in CHD. Methods: The literature was searched in December 2004 in the most relevant medical and economic databases. The medical evaluation was conducted on the basis of published RCT. The data from the studies regarding various angiographic, sonographic and clinical endpoints were checked for methodical quality and summarised in meta-analyses. Within the scope of economic evaluation the primary studies were analysed and modelling was performed, applying clinical effect estimates from the meta-analyses of the medical evaluation and current estimates of German costs. Results: Medical evaluation: Ten different stenttypes were used in the included 26 RCT. The results for heparin, silicon-carbide, carbon and PTFE coated stenttypes could not reveal any significant differences between the medical effectiveness of coated and uncoated stents. The application of sirolimus, paclitaxel, everolimus and 7-hexanoyltaxol eluting stents showed a significant lower restenosis at 6-9 months with decrease in the rate of restenosis for polymer-based sirolimus, paclitaxel and 7-hexanoyltaxol eluting stents. In contrast, the use of gold-coated and actinomycin-D eluting stents was associated with a significantly higher restenosis. The polymer-based sirolimus and paclitaxel eluting stents also showed a significant and considerable reduction in the rate of repeated percutaneous revascularisations at 6-12 months (3.5% vs. 19.7%; p<0.0001, RR=0.19 [95%CI: 0.11; 0.33] and 3.5% vs. 12.2%; p<0.0001, RR=0.30 [95%CI: 0

  4. Risk factors for in-stent restenosis of vertebral artery origin after stent implantation: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Fang-fang HAO

    2018-01-01

    Full Text Available Objective To systematically review the risk factors for in-stent restenosis (ISR of vertebral artery origin after sent implantation to provide theoretical foundation for clinical prevention and treatment. Methods Taking vertebral artery, vertebrobasilar insufficiency, stents, drug-eluting stents, self expandable metallic stents in English and Chinese as key words, retrospective clinical studies about risk factors for ISR of vertebral artery origin were searched by using PubMed, EMBASE/SCOPUS, Cochrane Library, China Biology Medicine (CBM, China National Knowledge Infrastructure (CNKI, Wanfang Data and VIP database from January 1, 1966 to March 30, 2017. Quality assessment and Meta-analysis were made by using Newcastle-Ottawa Scale (NOS and Stata 12.0 software. Results The research enrolled 3468 articles in all, from which 11 studies were chosen after excluding duplicates and those not meeting the inclusion criteria. A total number of 1352 patients were divided into ISR group (N = 440 and non-ISR group (N = 912. The ISR incidence rate of smokers was significantly higher than non-smokers (OR = 2.179, 95%CI: 1.373-3.458; P = 0.001. The differences of bare metal stents (BMS utilization rate (OR = 2.072, 95% CI: 1.560-2.753; P = 0.000 and drug-eluting stents (DES utilization rate (OR = 0.483, 95% CI: 0.363-0.641; P = 0.000 between ISR group and non-ISR group were statistically significant. Conclusions Smoking and using BMS are risk factors for ISR of vertebral artery origin, and using DES is protective factor. Due to limited study quality, more high-quality studies are needed to verify this conclusion. DOI: 10.3969/j.issn.1672-6731.2017.12.004

  5. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    Aims: Data are limited on the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with coronary stents. We examined the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with percutaneous coronary intervention (PCI). Methods and results......: All patients who underwent stent implantation from 2002 to 2005 were identified in the Western Denmark Heart Registry. The hazard ratio (HR) for death associated with stent thrombosis or in-stent restenosis was estimated with a Cox regression analysis with stent thrombosis or in-stent restenosis...... as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  6. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  7. Quantification of in-stent restenosis parameters in rabbits by micro-CT

    International Nuclear Information System (INIS)

    Langheinrich, A.C.; Zoerb, C.; Jajima, J.; Lommel, D.; Rau, W.S.; Walker, G.; Mueller, K.M.; Bohle, R.M.

    2005-01-01

    Purpose: The well-defined model of angioplasty and stent implantation in the rabbit aorta is useful in experimental studies of restenosis. This study was performed to evaluate the feasibility of Micro-CT for quantification of in-stent restenosis in a rabbit aortic in-stent restenosis model. Material and Methods: To induce in-stent restenosis seven female New Zealand rabbits underwent balloon dilation and denudation prior to stenting the abdominal aorta. After six weeks on atherogenic diet, animals were killed and the aorta was perfused with contrast agent. Micro-CT morphometric analysis of balloon and stent injured arteries obtained by 700 transverse sections (voxel size 10 μm) was compared to conventional histological analysis. Results: Intimal hyperplasia was present in stented and balloon injured arteries with a moderate intimal area assessed by Micro-CT and conventional histology (3.91±0.5 mm 2 vs. 4.18±0.42; r=0.9). High significant correlations between Micro-CT image analysis and conventional histomorphometry were obtained for lesion size, size of media, size of lumen and stent area (r=0.84 to 0.96). Conclusion: Micro-CT is feasible for quantitative information about restenosis following balloon angioplasty and stent implantation and has the potential to become a standard technique in many laboratories which will augment serial histology as the reference method for ex-vivo studies of restenosis. (orig.)

  8. Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

    Science.gov (United States)

    Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado

    2015-01-01

    Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a

  9. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    Directory of Open Access Journals (Sweden)

    Geanina Onuta

    2011-01-01

    Full Text Available Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s of long-term autoimmune diabetes on development of in-stent restenosis. We here describe the development of in-stent restenosis in long-term (~7 months spontaneously diabetic and age-matched, thymectomized, nondiabetic Diabetes Prone BioBreeding (BBDP rats (n=6-7 in each group. Diabetes was suboptimally treated with insulin and was characterized by significant hyperglycaemia, polyuria, proteinuria, and increased HbA1c levels. Stented abdominal aortas were harvested 28 days after stenting. Computerized morphometric analysis revealed significantly increased neointima formation in long-term diabetic rats compared with nondiabetic controls. In conclusion, long-term autoimmune diabetes in BBDP rats enhances in-stent restenosis. This model can be used to study the underlying pathogenetic mechanisms of diabetes-enhanced in-stent restenosis as well as to test new therapeutic modalities.

  10. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  11. Stenting versus endarterectomy for restenosis following prior ipsilateral carotid endarterectomy : An individual patient data meta-analysis

    NARCIS (Netherlands)

    Fokkema, Margriet; Vrijenhoek, Joyce E P; Ruijter, Hester M Den; Groenwold, Rolf H H; Schermerhorn, Marc L.; Bots, Michiel L.; Pasterkamp, Gerard; Moll, Frans L.; De Borst, Gert Jan

    2015-01-01

    Objective: To study perioperative results and restenosis during follow-up of carotid artery stenting (CAS) versus carotid endarterectomy (CEA) for restenosis after prior ipsilateral CEA in an individual patient data (IPD) metaanalysis. Background: The optimal treatment strategy for patients with

  12. Coronary collaterals and risk for restenosis after percutaneous coronary interventions: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Meier Pascal

    2012-06-01

    Full Text Available Abstract Background The benefit of the coronary collateral circulation (natural bypass network on survival is well established. However, data derived from smaller studies indicates that coronary collaterals may increase the risk for restenosis after percutaneous coronary interventions. The purpose of this systematic review and meta-analysis of observational studies was to explore the impact of the collateral circulation on the risk for restenosis. Methods We searched the MEDLINE, EMBASE and ISI Web of Science databases (2001 to 15 July 2011. Random effects models were used to calculate summary risk ratios (RR for restenosis. The primary endpoint was angiographic restenosis > 50%. Results A total of 7 studies enrolling 1,425 subjects were integrated in this analysis. On average across studies, the presence of a good collateralization was predictive for restenosis (risk ratio (RR 1.40 (95% CI 1.09 to 1.80; P = 0.009. This risk ratio was consistent in the subgroup analyses where collateralization was assessed with intracoronary pressure measurements (RR 1.37 (95% CI 1.03 to 1.83; P = 0.038 versus visual assessment (RR 1.41 (95% CI 1.00 to 1.99; P = 0.049. For the subgroup of patients with stable coronary artery disease (CAD, the RR for restenosis with 'good collaterals' was 1.64 (95% CI 1.14 to 2.35 compared to 'poor collaterals' (P = 0.008. For patients with acute myocardial infarction, however, the RR for restenosis with 'good collateralization' was only 1.23 (95% CI 0.89 to 1.69; P = 0.212. Conclusions The risk of restenosis after percutaneous coronary intervention (PCI is increased in patients with good coronary collateralization. Assessment of the coronary collateral circulation before PCI may be useful for risk stratification and for the choice of antiproliferative measures (drug-eluting stent instead bare-metal stent, cilostazol.

  13. Modelling and simulating in-stent restenosis with complex automata

    NARCIS (Netherlands)

    Hoekstra, A.G.; Lawford, P.; Hose, R.

    2010-01-01

    In-stent restenosis, the maladaptive response of a blood vessel to injury caused by the deployment of a stent, is a multiscale system involving a large number of biological and physical processes. We describe a Complex Automata Model for in-stent restenosis, coupling bulk flow, drug diffusion, and

  14. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  15. On the Possible Interaction Mechanism between Collateral Vessels and Restenosis

    NARCIS (Netherlands)

    Zun, P.S.; Hoekstra, A.G.

    2015-01-01

    Several clinical studies and their meta-analysis suggest that developed collateral vessels in the heart correlate to an increased risk of in-stent restenosis. The possible physiological interaction between the collateral development and in-stent restenosis is investigated in this study. Based on

  16. Experimental study of the preventive effect of 1'03Pd stent on in-stent restenosis in rabbit iliac artery

    International Nuclear Information System (INIS)

    Luo Quanyong; Chen Libo; Yuan Zhibin; Lu Hankui; Zhu Ruisen

    2003-01-01

    Objective: To investigate the ability of γ-emitting 103 Pd radioactive stent implantation for preventing in-stent restenosis in iliac artery of rabbits. Methods: Twenty New Zealand white rabbits were divided into six groups on the basis of radioactivity loading [2.22 (n=3), 5.55 (n=4), 9.25 (n=4), 14.8 (n=3), 22.2 (n=3), 33.3 MBq (n=3)]. 103 Pd stent was implanted in one of the two iliac arteries of each rabbit and nonradioactive stent in the contralateral artery. The rabbits were fed with high fat diet. Treatment efficiency was assessed by angiography and quantitative histomorphometry of the stented iliac segments 28 d after the implantation. Results: Quantitative histomorphometry analysis indicated that 103 Pd stents induced a significant reduction in neointimal area and the percentage of stenosis within radioactive stents was lower compared with that in the control stents. Nevertheless, the suppression of neointima formation by 103 Pd stent implantation was not in a dose-dependent manner. Conclusions: Low-dose intravascular brachytherapy via a γ-particle-emitting 103 Pd radioactive stent potently inhibits neointimal hyperplasia and prevents the in-stent restenosis in rabbit iliac artery. 103 Pd stent implantation probably can be employed as a novel means to prevent in-stent restenosis

  17. Effects of 32P radioactive stents on in-stent restenosis in a double stent injury model of the porcine coronary arteries

    International Nuclear Information System (INIS)

    Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron

    2001-01-01

    Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained

  18. Study on the application of big cup membranate stent on restenosis after stenting for carcinoma of esophago cardia

    International Nuclear Information System (INIS)

    Wang Xiuping; Yao Zhongqiang; Liu Jian; Zhang Yan

    2007-01-01

    Objective: To evaluate the clinical value of self-designed big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia. Methods: 12 cases of restenosis after stenting for carcinoma of esophago-cardia were involved in the study. Self-designed big cup membranate stent made by Nanjing Weichuang Company (the length of the cup was 3.5 cm)was placed into the constricted stent under guidance of fluoroscopy. Clinical effect, restenosis, and complications were observed during followed up. Results: All the 12 cases of big cup membranat stent placement went along smoothly without indigitation of the cup of the stent. Follow-up of 1.5-8 months showed that 2 cases developed severe restenosis on the big cup of the stem, resulting in third grade difficult deglutition. Among them, one occurred 1 month after stenting, caused by hyperplasia of large amount of granulation tissue; another occurred 6 months after stenting, caused by growth of tumor tissue. 3 cases developed mild to moderate restenosis, 2.3-7 months (mean: 4.6 months) after stenting, with result of first grade difficult deglutition. The remaining 7 cases (mean 5.6 months follow-up) did not have difficulty during deglutition. Conclusions: Application of big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia can effectively prevent the stent from moving downwards and thus lower down the rate of restenosis, and postpone the occurrence of restenosis. (authors)

  19. Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Benjamin Bondue

    2016-01-01

    Full Text Available Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis.

  20. Optimization of cardiovascular stent against restenosis: factorial design-based statistical analysis of polymer coating conditions.

    Directory of Open Access Journals (Sweden)

    Gayathri Acharya

    Full Text Available The objective of this study was to optimize the physicodynamic conditions of polymeric system as a coating substrate for drug eluting stents against restenosis. As Nitric Oxide (NO has multifunctional activities, such as regulating blood flow and pressure, and influencing thrombus formation, a continuous and spatiotemporal delivery of NO loaded in the polymer based nanoparticles could be a viable option to reduce and prevent restenosis. To identify the most suitable carrier for S-Nitrosoglutathione (GSNO, a NO prodrug, stents were coated with various polymers, such as poly (lactic-co-glycolic acid (PLGA, polyethylene glycol (PEG and polycaprolactone (PCL, using solvent evaporation technique. Full factorial design was used to evaluate the effects of the formulation variables in polymer-based stent coatings on the GSNO release rate and weight loss rate. The least square regression model was used for data analysis in the optimization process. The polymer-coated stents were further assessed with Differential scanning calorimetry (DSC, Fourier transform infrared spectroscopy analysis (FTIR, Scanning electron microscopy (SEM images and platelet adhesion studies. Stents coated with PCL matrix displayed more sustained and controlled drug release profiles than those coated with PLGA and PEG. Stents coated with PCL matrix showed the least platelet adhesion rate. Subsequently, stents coated with PCL matrix were subjected to the further optimization processes for improvement of surface morphology and enhancement of the drug release duration. The results of this study demonstrated that PCL matrix containing GSNO is a promising system for stent surface coating against restenosis.

  1. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  2. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  3. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  4. Influence of a pressure gradient distal to implanted bare-metal stent on in-stent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Thuesen, Leif

    2007-01-01

    pullback recording in the entire length of the artery. METHODS AND RESULTS: In 98 patients with angina pectoris, 1 de novo coronary lesion was treated with a bare-metal stent. After stent implantation, pressure wire measurements (P(d)=mean hyperemic coronary pressure and P(a)=mean aortic pressure) were......-stent restenosis after 9 months. CONCLUSIONS: A residual abnormal P(d)/P(a) distal to a bare-metal stent was an independent predictor of in-stent restenosis after implantation of a coronary bare-metal stent. Udgivelsesdato: 2007-Dec-11......BACKGROUND: Fractional flow reserve predicts cardiac events after coronary stent implantation. The aim of the present study was to assess the 9-month angiographic in-stent restenosis rate in the setting of optimal stenting and a persisting gradient distal to the stent as assessed by a pressure wire...

  5. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial.

    Science.gov (United States)

    Lal, Brajesh K; Beach, Kirk W; Roubin, Gary S; Lutsep, Helmi L; Moore, Wesley S; Malas, Mahmoud B; Chiu, David; Gonzales, Nicole R; Burke, J Lee; Rinaldi, Michael; Elmore, James R; Weaver, Fred A; Narins, Craig R; Foster, Malcolm; Hodgson, Kim J; Shepard, Alexander D; Meschia, James F; Bergelin, Robert O; Voeks, Jenifer H; Howard, George; Brott, Thomas G

    2012-09-01

    In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63-1·29; p=0·58). Female sex (1·79, 1·25-2·56), diabetes (2·31, 1·61-3·31

  6. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  7. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  8. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  9. Restenosis after stenting in symptomatic vertebral arterial orifice disease and considerations for better outcome

    Science.gov (United States)

    Chang, Jun Young; Park, Hyun; Kwon, Oki

    2017-01-01

    We have performed stenting in 11 patients with symptomatic vertebral arterial orifice stenosis refractory to medical treatment or impairment in anterior circulation. Three of the 11 patients experienced asymptomatic severe in-stent restenosis or occlusion. Bare metal stents were used in those three patients, two of whom received revascularization therapy. Development of sufficient cervical collateral channels reconstituting the distal vertebral artery was the common feature in patients with asymptomatic in-stent restenosis. In selecting appropriate stents, consideration of mechanical strength and drug-eluting properties of a stent according to characteristics of the target vessel is important to reduce the risk of in-stent restenosis. Any decision to perform revascularization should be based on the presence of abundant cervical collaterals as well as clinical symptoms of vertebrobasilar ischemia. PMID:28304206

  10. The effect of stent structure changes on the hemodynamics and the formation of in-stent restenosis

    International Nuclear Information System (INIS)

    Wu Xia; Xu Ke; Xiao Liang; Zhang Xitong; Su Hongying; Feng Bo

    2009-01-01

    Objective: To investigate the effect of stent structure changes on the formation of in-stent restenosis by studying the influence of these changes on the shear force to the vascular wall, on the velocity of flow and on the flow pattern. Methods: Five stent models were established by using Pro/engineer wildfire 3.0. Model A was regarded as control structure. On the base structure of model A, transverse link component was added to form model B, and vertical link component was added to form model C. The thickness of model D was twice than that of model A, and the meshes density of model E was twice than that of model A. Fluid models were built up by importing these stent models into computational fluid dynamics (CFD) software ansys11.0-CFX, then, CFD analysis was proceeded to study the effect of stent structure on hemodynamics. Results: After the stents were implanted, the percentage of low wall shear stress on the surface of model A, B, C, D and E was 7.78%, 6.65%, 1.48%, 16.52% and 12.12%, respectively. The percentage of D and E was obviously larger than that of A, while the percentage of B was markedly smaller than that of A. The velocity vector on the cross-sectional planes showed that the low velocity and eddy areas in D and E were much larger than that in A, while this area in C was smaller than that in A. Conclusion: The stent structure changes can cause obvious changes in hemodynamics in the implanted vessels. The increase in the thickness and meshes density of the stent is the main factor that induces the formation of low wall shear stress, which will precipitate the development of in-stent restenosis. The added vertical link component will reduce the area of low wall shear stress as well as the occurrence of in-stent restenosis. (authors)

  11. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  12. Simple balloon dilation for drug-eluting in-stent restenosis: An optical coherent tomography analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arikawa, Ryo [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Yamaguchi, Hiroshi, E-mail: hyamaguchi@tsm.bbiq.jp [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Takaoka, Junichiro; Miyamura, Akihiro; Atsuchi, Nobuhiko; Ninomiya, Toshiko; Atsuchi, Yoshihiko [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Ohishi, Mitsuru [Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima (Japan); Terashima, Mitsuyasu [Department of Cardiology, Toyohashi Heart Center, Toyohashi (Japan); Kaneda, Hideaki [Okinaka Memorial Institute for Medical Research, Tokyo (Japan)

    2015-01-15

    Background: Although drug-eluting stent (DES) has significantly reduced restenosis, the treatment of DES-in-stent restenosis (ISR) remains a challenge with high restenosis rate. Methods: We examined whether morphologic appearance of restenosis tissue by optical coherent tomography (OCT) had an impact on outcomes after balloon angioplasty for DES-ISR. The morphologic appearance of restenosis tissue was qualitatively assessed for tissue structures such as homogeneous, layered, and heterogeneous patterns. Results: Using OCT, 50 patients with DES-ISR were divided into 2 groups: 25 lesions with homogeneous or layered patterns (homo/layered group) and 25 lesions with heterogeneous patterns (hetero group). Acute gain was larger in the hetero group (1.33 ± 0.41 mm vs. 1.06 ± 0.32 mm in the homo/layered group, P = 0.03). On intravascular ultrasound analysis, post-procedural percent neointimal area was smaller in the hetero group (27.4 ± 9.2% vs. 34.0 ± 11.2% in the homo/layered group, P = 0.05). Angiographic follow-up was performed in 37 lesions (74%). Follow-up minimal lumen diameter was larger in the hetero group (1.75 ± 0.89 mm vs. 1.01 ± 0.81 mm in the homo/layered group, P = 0.04). Target lesion revascularization rates tended to be lower in the hetero group (20% vs. 43% in the homo/layered group, P = 0.12). Conclusions: Balloon angioplasty was more effective for DES-ISR with heterogeneous tissue appearance than DES-ISR with homogeneous/layered tissue appearance. OCT assessment of DES-ISR morphology may be a useful adjunct in determining clinical strategies. Simple balloon dilatation is a possible treatment strategy for DES-ISR lesions with a heterogeneous appearance on OCT images.

  13. The Dresden in-stent restenosis radiation trial (DIRRT) with liquid-filled 188Re balloon

    International Nuclear Information System (INIS)

    Kropp, J.; Runge, R.R.; Reynen, K.; Koeckeritz, U.; Schmeisser, A.; Strasser, R.H.

    2002-01-01

    Full text: In some studies intracoronary radiation therapy (IRT) to minimize the restenosis rate after PTCA proved to be effective. We evaluated the performance, safety and effectiveness of IRT with 188 Re-perrhenate filled into a standard PTCA balloon. This kind of IRT allows a self-centering homogenous dose distribution to the vessel wall. 107 patients (pts) with a mean age of 63 years (81 m, 26 fin) with in-stent restenosis (type B in 39 %, type C in 61 %) and proven ischemia were included. After routine re-PTCA with or without additional stent implantation a second standard balloon was placed into the PTCA area and filled with β - -emitting liquid 188 Re at 3 atm. Irradiation time was 525 ± 167 sec to achieve a dose of 30 Gy at 0.5 mm depth of the vessel wall. In only one procedure there was a disconnection of the 188 Re containing system and the catheter but no contamination of the cath table or lab was measured. In 16 coronaries 21 stents were additionally implanted. In the follow-up 4 stent thromboses (1 day, 37 days, 2 x 6 months) with subsequent myocardial infarction were noticed, all in pts with additionally implanted stents. 57 pts had control angiography after 4 to 6 months after therapy and 41 after one year. Restenosis (stenosis > 50 % of luminal diameter) was shown in 9 out of 12 pts (75 %) with additionally implanted stents but only in 4 out of 24 pts (17 %) with PTCA alone. Reocclusion was noticed in 3 (25 %) pts with additional stent but only in 1 pt (4 %) without. No re-restenosis occurred in 20 patients which were without finding after 6 months. Intracoronary radiation therapy (IRT) with β - -emitting liquid-filled 188 Re balloon is a safe and effective therapy method which might be used routinely. Long-term results seem satisfactory in a patient group with in-stent restenosis and high risk of re-restenosis. But the positive effect of irradiation is abolished if an additional stent after PTCA is needed. (author)

  14. The Incidence and Risk Factors of In-Stent Restenosis for Vertebrobasilar Artery Stenting.

    Science.gov (United States)

    Zheng, Dai; Mingyue, Zhu; Wei, Shi; Min, Li; Wanhong, Chen; Qiliang, Dai; Yongjun, Jiang; Xinfeng, Liu

    2018-02-01

    In-stent restenosis (ISR) remains a challenge for vertebrobasilar artery stenting (VBAS). We aimed to investigate the incidence and risk factors of ISR. This was a retrospective study. From July 28, 2005, to July 30, 2015, patients who received VBAS with an angiographic follow-up time of 6 to 12 months after surgery were enrolled. The clinical and angiographic issues were recorded and analyzed. In total, 283 patients with 335 stents were incorporated into the study. Vertebral ostial lesions accounted for 73.4% (246/335) of the lesions. During the follow-up period, 58 patients with 60 stents experienced ISR (>50%). Stepwise logistic regression analysis showed that the degree of residual stenosis, stent diameter, and alcohol consumption were independent predictors of ISR. Our study demonstrated the incidence and risk factors of ISR after VBAS. This retrospective study with the largest cohort to date provided insight into the occurrence of ISR after VBAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Engineering Radioactive Stents for the Prevention of Restenosis

    International Nuclear Information System (INIS)

    Bruce Thomadsen; Nickles, Robert J.; Larry DeWerd; Douglass Henderson; Jonathan Nye; Wes Culberson; Stephen Peterson; Michael Meltsner; Liyong Lin

    2004-01-01

    Radiation has become an accepted treatment for the prevention of restenosis (re-blockage) of coronary arteries following angioplasty. Radioactive stents could be the easiest method of delivery for the radiation, although clinical trials were disappointing. One likely reason was the choice of P-32 as the radionuclide, which fails to match the biological needs of the problem. What radionuclide would perform best remains unknown. This project established the physical infrastructure necessary for a rational investigation to determine the optimum radiological characteristics for radioactive stents in the prevention of restenosis following angioplasty. The project investigated methods to activate coronary stents with radionuclides that spanned a range of energies and radiation types that could provide a mapping of the biological response. The project also provided calibration methods to determine the strength of the stents, an a process to calculate the dose distribution actually delivered to the patient's artery--quantities necessary for any future scientific study to improve the effectiveness of radioactive stents. Such studies could benefit the thousands of patients who receive angioplasty each year

  16. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  17. Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis

    International Nuclear Information System (INIS)

    Kim, D. E.; Park, S. A.; Kim, C. K.; Chang, J. A.; Jeong, J. W.; Oh, S. G.; Lee, C.

    2007-01-01

    It appears logical that myocardial perfusion should be fixed and not reversible, in the territory supplied by a dilated coronary artery. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis. Sixty-six patients that underwent M-SPECT within 24 hours of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively. Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis. This study shows that the predictive value of reversible perfusion defects on M-SPECT early after stent implantation with respect to the incidence of late restenosis was 47% in patients with a reversible defect, and 18% in those without it

  18. In-stent restenosis of innominate artery with critical stenosis of right internal carotid artery

    International Nuclear Information System (INIS)

    Hussain, S.; Raza, A.; Ahmed, W.

    2011-01-01

    A lady with aortitis syndrome developed in-stent restenosis (ISR) of the innominate artery stent and critical stenosis of right internal carotid artery. The therapeutic challenge was gaining access to the carotid vessel, after treating the innominate artery ISR and all the while using distal protection to circumvent potential cerebral embolism. Percutaneous transluminal angioplasty (PTA) with or without stenting is a safe therapeutic option for re-vascularization of the supra aortic vessels. In the event of re-stenosis, re-treatment with PTA and stenting is safe. Ample evidence-base exists now for carotid artery stenting (CAS) in preference to carotid endarterectomy in patients with stenotic lesions of the carotid vessels. (author)

  19. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  20. Laser Atherectomy for Treatment of Femoropopliteal In-Stent Restenosis.

    Science.gov (United States)

    Armstrong, Ehrin J; Thiruvoipati, Thejasvi; Tanganyika, Kundai; Singh, Gagan D; Laird, John R

    2015-08-01

    To investigate if laser atherectomy with adjunctive balloon angioplasty can improve endovascular treatment outcomes for femoropopliteal in-stent restenosis (ISR). A dual center study included 135 symptomatic patients (mean age 71 years; 76 men) who underwent endovascular treatment of femoropopliteal ISR between 2006 and 2013. Of these, 54 (40%) were treated with laser atherectomy and the remaining 81 patients with balloon angioplasty alone. Angiographic images were reviewed for lesion morphology and characteristics, TransAtlantic InterSociety Consensus (TASC) II classification, and distal runoff. Class I ISR was defined as focal lesions ≤50 mm, class II ISR as lesions >50 mm, and class III ISR as stent total occlusion. Recurrent ISR was determined by a peak systolic velocity ratio >2.4 by duplex ultrasound. Patients treated with laser atherectomy had longer mean ISR lesion length (222 vs 114 mm, patherectomy and rates of recurrent restenosis or occlusion for patients with class I/II ISR, but there was a significantly lower rate of target lesion revascularization at 2 years among patients treated with laser atherectomy (14% vs 44%, p=0.05). In comparison, patients with class III ISR treated with laser atherectomy had lower rates of recurrent restenosis at 1 year (54% vs 91%, p=0.05) and 2 years (69% vs 100%, p=0.05). Patients with class III ISR treated with laser atherectomy also had lower rates of recurrent in-stent occlusion at 2-year follow-up (33% vs 71%, p=0.04). When used to treat complex ISR, including in-stent occlusions, laser atherectomy with adjunctive balloon angioplasty may be associated with improved patency. © The Author(s) 2015.

  1. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  2. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    NARCIS (Netherlands)

    Onuta, Geanina; Groenewegen, Hendrik C.; Klatter, Flip A.; Boer, Mark Walther; Goris, Maaike; van Goor, Harry; Roks, Anton J. M.; Rozing, Jan; de Smet, Bart J. G. L.; Hillebrands, Jan-Luuk

    2011-01-01

    Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on development of

  3. Long-term type 1 diabetes enhances in-stent restenosis after aortic stenting in diabetes-prone BB rats

    NARCIS (Netherlands)

    J.-L. Hillebrands (Jan-Luuk); G. Onuta (Geanina); H.C. Groenewegen (Hendrik); F.A. Klatter (Flip); M. Walther Boer (Mark); M. Goris (Maaike); H. van Goor (Harry); A.J.M. Roks (Anton); J. Rozing (Jan); B.J.G.L. de Smet (Bart)

    2011-01-01

    textabstractType 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on

  4. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  5. Factors Associated with In-stent Restenosis in Patients Following Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Dedi Wihanda

    2015-07-01

    Full Text Available Aim: to determine factors associated with In-Stent Restenosis (ISR in patients following Percutaneous Coronary Intervention (PCI. Methods: a retrospective cross-sectional study was conducted using secondary information from medical records of post-PCI patients who underwent follow-up of angiography PCI between January 2009 and March 2014 at The Integrated Cardiovascular Service Unit, Cipto Mangunkusumo Hospital, Jakarta. Angiographic ISR was defined when the diameter of stenosis ≥50% at follow-up angiography including the diameter inside the stent and diameter with five-mm protrusion out of the proximal and distal ends of the stent. Results: there were 289 subjects including 133 subjects with and 156 subjects without ISR. The incidence of ISR in patients using of bare-metal stent (BMS and drug-eluting stent (DES were 61.3% and 40.7%, respectively. Factors associated with ISR are stent-type (OR=4.83, 95% CI 2.51-9.30, stent length (OR=3.71, 95% CI 1.99-6.90, bifurcation lesions (OR=2.43, 95% CI 1.16-5.10, smoking (OR=2.30, 95% CI 1.33-3.99, vascular diameter (OR=2.18, 95% CI 1.2-3.73, hypertension (OR=2.16, 95% CI 1.16-4.04 and diabetes mellitus (OR=2.14, 95% CI 1.23-3.70. Conclusion: stent type, stent length, bifurcation lesions, smoking, vascular diameter, hypertension and DM are factors associated with ISR in patients following PCI. Key words: bare-metal stent; drug-eluting stent; in-stent restenosis.

  6. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  7. A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); De Cecco, Carlo N.; Yamada, Ricardo T.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Fuller, Stephen R. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Vogl, Thomas J.; Wichmann, Julian L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Todoran, Thomas M. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2016-12-15

    To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F{sub 0}.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F{sub 0}.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F{sub 0}.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F{sub 0}.5 (90.9, 94.1, 89.3 %). 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. (orig.)

  8. Rotational and aspiration atherectomy for infrainguinal in-stent restenosis.

    Science.gov (United States)

    Beschorner, Ulrich; Krankenberg, Hans; Scheinert, Dierk; Sievert, Horst; Tübler, Thilo; Sixt, Sebastian; Noory, Elias; Rastan, Aljoscha; Macharzina, Roland; Zeller, Thomas

    2013-03-01

    To report feasibility and safety of the Pathway PV™ Atherectomy System during percutaneous peripheral vascular interventions of in-stent restenosis. 33 patients (66.7 % men; mean age 68.7 years; 39.4 % diabetics) with symptomatic infrainguinal in-stent restenosis were enrolled at 5 study sites. Primary study endpoint was the 30-day serious adverse event (SAE) rate. At one study site a subgroup of 13 patients was scheduled for additional follow-up examinations with duplex. Forty lesions with a mean lesion length of 85.7 mm (range 6 - 370 mm) were treated including total occlusions (20 %) and infrapopliteal lesions (5 %). In sixteen target lesions (40 %) procedural success was reached with atherectomy alone, 23 lesions (57.5 %) received adjunctive percutaneous transluminal angioplasty to obtain a sufficient angiographic result. Freedom from device-related SAEs was 100 %. Overall there were 11 unexpected adverse events in 11 patients, two of which were serious (retroperitoneal bleeding and access site infection). The ankle-brachial index increased significantly from 0.65 ± 0.13 at baseline to 0.82 ± 0.15 at 30 days. Mean Rutherford category improved from 2.8 ± 0.7 at baseline to 1.0 ± 1.2. In the subgroup with longer follow- up primary patency was 33 % after 12 months and 25 % after 24 months. Secondary patency was 92 % after 12 and 24 months. The use of the Pathway PV™ System during percutaneous peripheral vascular interventions of in-stent restenosis appears to be feasible and safe but does not seem to offer a sustainable solution regarding long term patency. A combination with drug eluting balloon angioplasty could be an interesting option and should be evaluated in further clinical trials.

  9. Matrix metalloproteinase 9 level as an indicator for restenosis following cervical and intracranial angioplasty and stenting

    Directory of Open Access Journals (Sweden)

    Jun-peng Liu

    2015-01-01

    Full Text Available Cervical and intracranial angioplasty and stenting is an effective and safe method of reducing the risk of ischemic stroke, but it may be affected by in-stent restenosis. The present study investigated serum level of matrix metalloproteinase 9 as a predictor of restenosis after 40 patients underwent cervical and/or intracranial angioplasty and stenting. Results showed that restenosis occurred in 30% (3/10 of patients when the serum level of matrix metalloproteinase 9 at 3 days after surgery was 2.5 times higher than preoperative level. No restenosis occurred when the serum level of matrix metalloproteinase 9 at 3 days after surgery was not 2.5 times higher than preoperative level. Restenosis occurred in 12% (2/17 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for more than 30 days after surgery, but only occurred in 4% (1/23 of patients when the serum level of matrix metalloproteinase 9 was higher than preoperative level for less than 30 days after surgery. However, the differences observed were not statistically significant (P > 0.05. Experimental findings indicate that when the serum level of matrix metalloproteinase 9 is 2.5 times higher than preoperative level at 3 days after cervical and intracranial angioplasty and stenting, it may serve as a predictor of in-stent restenosis.

  10. Drug-eluting stents studies in mice: Do we need atherosclerosis to study restenosis?

    NARCIS (Netherlands)

    Pires, N.M.M.; Jukema, J.W.; Daemen, M.J.A.P.; Quax, P.H.A.

    2006-01-01

    In 2001, the first human study with drug-eluting stents (DES) was published showing a nearly complete abolition of restenosis by using a sirolimus-eluting stent. This success was very encouraging to test new compounds in combination with the DES platform. Nevertheless, several other anti-restenotic

  11. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    presenting with a DES or bare-metal stent (BMS) in-stent restenosis. Methods: The ``Nordic Intravascular Ultrasound Study (NIVUS)'' study was conducted in Nordic and Baltic countries as a prospective multicenter registry. Two hundred nine patients (DES n = 121 and BMS n = 88) with instent restenosis were...

  12. Late In-Stent Restenosis of the Abdominal Aorta in a Patient with Takayasu's Arteritis and Related Pathology

    International Nuclear Information System (INIS)

    Ishibashi-Ueda, Hatsue; Yutani, Chikao; Kuribayashi, Sachio; Takamiya, Makoto; Imakita, Masami; Ando, Motomi

    1999-01-01

    This report describes an in-stent restenosis of the infrarenal aorta in a patient with Takayasu's arteritis in a nonactive state. A 10-mm-diameter Wallstent had been deployed 42 months previously. The stented restenosed segment was replaced by a surgical graft. Histopathological examination of the excised aortic segment showed a thin layer of fibrocellular neointima and massive organized and calcified thrombus. To our knowledge, this is the first histopathological report of a late in-stent restenosis of the abdominal aorta in Takayasu's arteritis. RID='''' ID='''' Correspondence to: H. Ishibashi-Ueda, M.D

  13. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. CYP2C19⁎2 Polymorphism in Chilean Patients with In-Stent Restenosis Development and Controls

    Directory of Open Access Journals (Sweden)

    Jenny Ruedlinger

    2017-01-01

    Full Text Available Clopidogrel is an antiplatelet drug especially used in patients undergoing percutaneous coronary interventions (PCI. Polymorphisms within CYP2C19 can result in important interindividual variations regarding therapeutic efficacy. Therefore, we aimed to evaluate the impact of the CYP2C19⁎2 variant (rs4244285 on in-stent restenosis occurrence in Chilean patients who underwent PCI and received clopidogrel. A total of 77 cases with stenosis >50% in the angioplasty site (62.75 ± 9.8 years, 80.5% males and 86 controls (65.45 ± 9.8 years, 72.1% males were studied. The polymorphism was genotyped using TaqMan® Drug Metabolism Genotyping Assays. Overall, CYP2C19⁎2 allele frequency was 8.3%. Diabetes, chronic lesions, and bare metal stents (BMS were observed more often in cases than in controls (p = 0.05, p = 0.04, and p = 0.02, resp.. Genotypic frequencies did not differ significantly between the groups (p = 0.15. Nonetheless, the mutated allele was observed in a greater proportion in patients without in-stent restenosis (p = 0.055. There was no significant association between the rs4244285 variant and the occurrence of in-stent restenosis after PCI (OR = 0.44; 95% CI: 0.19 to 1.04; p = 0.06. In summary, no association was identified between the CYP2C19⁎2 variant and the development of coronary in-stent restenosis.

  15. Factors inducing in-stent restenosis: an in-vitro model.

    Science.gov (United States)

    Santin, M; Morris, C; Harrison, M; Mikhalovska, L; Lloyd, A W; Mikhalovsky, S

    2004-05-01

    In-stent restenosis is caused by the proliferation of the smooth muscle cells (SMCs) following a host response towards the implanted device. However, the precise biochemical and cellular mechanisms are still not completely understood. In this paper, the behaviour of SMCs has been investigated by an in vitro model where the cells were stimulated by platelet derived growth factor (PDGF) on tissue-like substrates as well as on biomaterials such as stainless steel (St) and diamond-like carbon (DLC)-coated St. The results demonstrated that SMCs have a completely different adhesion mode on St and become particularly prone to proliferation and pro-inflammatory cytokine secretion under PDGF stimulus. This would suggest that restenosis may caused by the accidental contact of the SMC with the St substrate under an inflammatory insult.

  16. Role of Esophageal Metal Stents Placement and Combination Therapy in Inoperable Esophageal Carcinoma: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Lai, Andrew; Lipka, Seth; Kumar, Ambuj; Sethi, Sajiv; Bromberg, David; Li, Nanxing; Shen, Huafeng; Stefaniwsky, Lilia; Brady, Patrick

    2018-04-01

    More than 50% of patients with esophageal cancer already have inoperable disease at the time of diagnosis. Controversy surrounds the outcomes of patients with advanced esophageal cancer who receive palliative care by either stent alone or stent plus an additional modality. We set out to perform a systematic review and meta-analysis of studies assessing the use of metal stents as treatment options for symptomatic improvement, survival, and adverse events. We searched Embase, MEDLINE, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception until January 14, 2016, as well as other databases for randomized controlled trials (RCTs) comparing esophageal stent versus either esophageal stent plus brachytherapy, radiotherapy, or chemotherapy. For quality assurance purposes throughout the systematic review, multiple independent extractions were performed, and the process was executed as per the standards of the Cochrane collaboration. Primary outcomes were mean change in dysphagia score, overall survival, and quality of life. Secondary outcomes were adverse events including fever, severe pain, aspiration, fistula, stent migration, perforation, and restenosis. Eight RCTs enrolling 732 patients were included with three distinct comparisons: stents combination therapy vs stents alone (5 studies, n = 417), stents alone versus brachytherapy alone (2 studies, n = 274), and stents + brachytherapy vs brachytherapy alone (1 study, n = 41). Stents combination therapy was defined as stents plus radiotherapy, chemotherapy, or both. Mean change in dysphagia scores favored stents combination therapy versus stents alone, and the effect was seen in patients surviving longer than 3 months. Stents combination therapy was also associated with a more favorable overall survival. The risks of stent migration, aspiration pneumonia, and restenosis were lower in the stents combination group compared to stents alone, while the risks of severe pain, hemorrhage, and

  17. Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography

    International Nuclear Information System (INIS)

    Pan, Jingwei; Lu, Zhigang; Wei, Meng; Zhang, Jiayin; Li, Minghua

    2013-01-01

    To evaluate the diagnostic accuracy of Mehran's in-stent restenosis (ISR) classification by coronary computed angiography (CCTA), with reference to invasive coronary angiography (ICA). Consecutive symptomatic patients, who had clinically suspected ISR and implanted stent diameter ≥ 3 mm, were prospectively enrolled in our study. Mehran's classification was employed by CCTA and ICA to classify ISR lesions into four subtypes: focal, diffuse intrastent, diffuse proliferative and total occlusion. CCTA and ICA measurement of lesion length was further compared. Sixty-one patients with 101 implanted stents were included in our study. The overall sensitivity, specificity, PPV and NPV of CCTA diagnosis of binary ISR, as shown by patient-based analysis (n = 61), were 100 % (49/49), 75 % (8/12), 92.45 % (49/53) and 100 % (8/8) respectively. Mehran's classification of CCTA correlated well with ICA findings. The diagnostic accuracy of CCTA for class I, class II, class III and class IV lesions was 92.5 %, 91.67 %, 100 % and 100 % respectively. Lesion length was assessed to be significantly longer with CCTA than with ICA (11.03 ± 5.89 mm versus 8.56 ± 4.99 mm, P < 0.001). Angiographic patterns of in-stent restenosis can be accurately classified by coronary computed angiography. The lesion length measured by CCTA is longer than that assessed by invasive coronary angiography. (orig.)

  18. Randomized comparison between intracoronary β-radiation brachytherapy and implantation of paclitaxel-eluting stents for the treatment of diffuse in-stent restenosis

    International Nuclear Information System (INIS)

    Schukro, Christoph; Syeda, Bonni; Kirisits, Christian; Schmid, Rainer; Pichler, Philipp; Pokrajac, Boris; Lang, Irene; Poetter, Richard; Glogar, Dietmar

    2007-01-01

    Background and purpose: Intracoronary brachytherapy was the primary therapeutic option for the treatment of in-stent restenosis (ISR) during the last years. Especially for the treatment of diffuse ISR (lesions >10 mm), β-source brachytherapy was significantly superior to singular balloon angioplasty. Despite lacking clinical database, the implantation of drug eluting stents recently became a common procedure for the treatment of ISR. This randomized trial aimed to compare the efficacy of β-brachytherapy with β-radioisotopes 90 Sr/ 90 Y and paclitaxel-eluting stent implantation for the treatment of diffuse ISR. Material and methods: Thirty-seven patients with diffuse ISR were randomly assigned to β-brachytherapy after balloon angioplasty (Beta-Cath TM in 17 patients) or paclitaxel-eluting stent implantation (Taxus-Express2 TM in 20 patients). Six-month clinical follow-up was obtained for all patients, while angiographic follow-up was available for 30 patients. Results: Binary ISR (restenosis >50%) within target segment was observed in three patients treated with Beta-Cath TM , of which one needed target segment revascularisation for recurrent ISR, whereas no significant restenosis occurred in the patients treated with Taxus-Express2 TM (P = 0.037). No further major adverse cardiac (target segment revascularisation, myocardial infarction, death) was found in either group (P = NS). Stent implantation was the more time-saving (31 ± 11 min versus 60 ± 23 min, P TM arm, we found no difference in clinical outcome after implantation of paclitaxel-eluting stents for the treatment of diffuse ISR when compared to β-brachytherapy

  19. Experimental study of 103Pd stents for preventing the restenosis of biliary duct

    International Nuclear Information System (INIS)

    Gao Qinyi; Shu Qiang; Lu Xiangdong; Li Yaming; He Guijin; Pei Zhuguo; Xu Shuhe

    2004-01-01

    Objective: To explore the feasibility of preventing biliary duct restenosis with the stent treated with 103 Pd and to elucidate the mechanisms of the inhibition of the smooth muscle cell proliferation and the increase of apoptosis. Methods: The experimental dogs were randomly divided into common-stent group and 103 Pd stent group, each of 6 animals. Pathohistology, cell apoptosis, immunohistochemistry for proliferating cell nuclear antigen (PCNA), the expression of gene p53 by in situs hybridization, the test of the peripheral blood and measurement of radiation of tissue around the stent were studied. Results: The utmost intimal thickness of biliary duct in the 103 Pd stent group was found to be obviously less compared to that in common-stent group after 30 d, the percentages of the stenosis of the biliary duct were (54.73 ± 21.64)% and (17.61 ± 14.52)%, respectively, there was a significant difference between two groups (P 103 Pd stent group, and decreased in the common-stent group; the expression of PCNA of biliary smooth muscle cells of 103 Pd group was weaker compared with that in the common-group. Conclusion: 103 Pd stent may inhibit the proliferation of smooth muscle cells and prevent the restenosis of biliary duct. (authors)

  20. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  1. Clinical results of Intracoronary Brachytherapy (ICBT) for multiple in-stent restenosis

    International Nuclear Information System (INIS)

    Stadler, P.; Schaefer, C.; Chaber, S.; Putnik, K.; Treutwein, M.; Koelbl, O.; Muders, F.

    2006-01-01

    Background and purpose: treatment of in-stent restenosis (ISR) with percutaneous coronary intervention (PCI) alone is often followed by early re-restenosis. The present study focused on the effect of intracoronary brachytherapy (ICBT) on multiple in-stent restenosis (MISR) after repeated PCI. Patients and methods: 40 patients (27 male, 13 female, age: 66 ± 9 years) with MISR (two to six ISRs, median three ISRs) were retrospectively analyzed. All patients were treated by using the Novoste registered Beta-Cath trademark 3.5F System after PCI. The target vessel received 18.4-25.3 Gy of radiation at a depth of 2 mm from the center of the source. The restenosis-free survival and overall survival were calculated by Kaplan-Meier analysis (log-rank). The time interval between last PCI without ICBT and the consecutive recurrence was compared with the follow-up time after PCI with ICBT. Results: the 3-year overall survival rate after ICBT was 93%. The 0.5-, 1-, 2-, and 3-year ISR-free survival rates after PCI + ICBT were 81%, 72%, 52%, and 38%, respectively. After PCI alone, the 0.5-, 1-, and 2-year ISR-free survival rates were 30%, 13%, and 0%, respectively. This difference was highly significant (p < 0.0001). Patients with more than three ISRs before ICBT had a better outcome (3-year ISR-free survival: 80%) than patients with only two or three ISRs before ICBT (3-year ISR-free survival: 25%; p < 0.05). Conclusion: ICBT is highly effective and safe in patients with ISR. The results of this study are in accordance with the WRIST and BETA-WRIST data. After 6 months both studies revealed an ISR-free survival rate of 86% (WRIST) and 66% (BETA-WRIST), respectively. The ISR rates in the own control group (70%) were comparable to the placebo groups in WRIST (68%) and BETA-WRIST (72%). Interestingly, patients with more than three ISRs before ICBT had the lowest ISR rate after ICBT. (orig.)

  2. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  3. Microwave Spectrometry for the Assessment of the Structural Integrity and Restenosis Degree of Coronary Stents

    Science.gov (United States)

    Arauz-Garofalo, Gianluca; Lopez-Dominguez, Victor; Garcia-Santiago, Antoni; Tejada, Javier; O'Callaghan, Joan; Rodriguez-Leor, Oriol; Bayes-Genis, Antoni; Gmag Team; Hugtp Team; Upc Team

    2013-03-01

    Cardiovascular disease is the main cause of death worldwide. Coronary stents are one of the most important improvements to reduce deaths from cardiovascular disorders. Stents are prosthetic tube-shaped devices which are used to rehabilitate obstructed arteries. Despite their obvious advantages, reocclusion occurs in some cases arising from restenosis or structural distortions, so stented patients require chronic monitoring (involving invasive or ionizing procedures). We study microwave scattering spectra (between 2.0 - 18.0 GHz) of metallic stents in open air, showing that they behave like dipole antennas in terms of microwave scattering. They exhibit characteristic resonant frequencies in their microwave absorbance spectra that are univocally related to their length and diameter. This fact allows one to detect stent fractures or collapses. We also investigate the ``dielectric shift'' in the frequency of the resonances mentioned above due to the presence of different fluids along the stent lumen. This shift could give us information about the restenosis degree of implanted stents.

  4. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy

    Energy Technology Data Exchange (ETDEWEB)

    Martí, David, E-mail: docalcala@hotmail.com [Department of Cardiology, Hospital Central de la Defensa, Madrid (Spain); López, Edurne; Álvarez, Salvador; Palazuelos, Jorge; Rada, Ignacio [Department of Cardiology, Hospital Central de la Defensa, Madrid (Spain); Alfonso, Fernando [Department of Cardiology, Hospital Universitario de La Princesa, Madrid (Spain)

    2016-12-15

    The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. - Highlights: • Optical coherence tomography (OCT) has the unique ability to detect lipid accumulation within the stent margins (i.e. neoatherosclerosis). • Lipid-rich tissues produce light absorption and therefore they typically attenuate backward signals. • Occlusive neoatherosclerosis may appear even in optimally implanted drug eluting stents. • OCT identification of restenosis mechanisms may have implications not only in the interventional strategy, but also in the long-term medical treatment.

  5. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy

    International Nuclear Information System (INIS)

    Martí, David; López, Edurne; Álvarez, Salvador; Palazuelos, Jorge; Rada, Ignacio; Alfonso, Fernando

    2016-01-01

    The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. - Highlights: • Optical coherence tomography (OCT) has the unique ability to detect lipid accumulation within the stent margins (i.e. neoatherosclerosis). • Lipid-rich tissues produce light absorption and therefore they typically attenuate backward signals. • Occlusive neoatherosclerosis may appear even in optimally implanted drug eluting stents. • OCT identification of restenosis mechanisms may have implications not only in the interventional strategy, but also in the long-term medical treatment.

  6. Impact of Angioscopic Evaluation for Femoropopliteal In-Stent Restenosis Before and After Excimer Laser Atherectomy.

    Science.gov (United States)

    Idemoto, Akiko; Okamoto, Naotaka; Tanaka, Akihiro; Mori, Naoki; Nakamura, Daisuke; Yano, Masamichi; Makino, Nobuhiko; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Nishino, Masami

    2017-07-01

    In-stent restenosis (ISR) is a prevalent problem following stenting of femoropopliteal lesions. A potential novel treatment modality for ISR including excimer laser atherectomy (ELA) has become available. We performed ELA for in-stent chronic total occlusion (CTO) of femoropopliteal lesions and evaluated lesion morphology before and after ELA by angioscopy in 2 patients. The angioscopic findings clearly showed removal of in-stent thrombi after ELA. Thus, ELA may be effective for in-stent CTO of femoropopliteal lesions. This is the first report describing the direct visualization of ELA effect for vaporization of thrombi in femoropopliteal in-stent lesions by angioscopy.

  7. Higher plasma level of STIM1, OPG are correlated with stent restenosis after PCI.

    Science.gov (United States)

    Li, Haibin; Jiang, Zhian; Liu, Xiangdong; Yang, Zhihui

    2015-01-01

    Percutaneous Coronary Intervention (PCI) is one of the most effective treatments for Coronary Heart Disease (CHD), but the high rate of In Stent Restenosis (ISR) has plagued clinicians after PCI. We aim to investigate the correlation of plasma Stromal Interaction Molecular 1 (STIM1) and Osteoprotegerin (OPG) level with stent restenosis after PCI. A total of 100 consecutive patients with Coronary Heart Disease (CHD) received PCI procedure were recruited. Coronary angiography was performed 8 months after their PCI. Then patients were divided into 2 groups: observation group was composed by patients who existing postoperative stenosis after intervention; Control group was composed by patients with no postoperative stenosis. The plasma levels of STIM, OPG in all patients were tested before and after intervention. Pearson correlation and multiple linear regression analysis were performed to analysis the correlation between STIM, OPG level and postoperative stenosis. 35 cases were divided into observation group and other 65 were divided into control group. The plasma levels of STIM, OPG have no statistical difference before their PCI procedure, but we observed higher level of High-sensitivity C-reactive protein (Hs-CRP) existed in observation group. We observed higher level of plasma STIM, OPG in observation group when compared with control group after PCI procedure (P PCI, which could provide useful information for the restenosis control after PCI.

  8. [Meta-analysis of percutaneous transluminal atherectomy in the treatment for in-stent restenosis of lower extremity peripheral artery disease].

    Science.gov (United States)

    Li, Weihao; Zhang, Tao; Liu, Yunfeng; Zhang, Yongbao; Li, Qingle; Zhang, Xiaoming; Shen, Chenyang

    2015-11-24

    To evaluate the clinical safety and efficacy of percutaneous transluminal atherectomy for in-stent restenosis (ISR) in patients with low extremity peripheral arterial diseases (PAD). PubMed, Elsevier, EBSCO, Spring databases and Cochrane Library were searched for relevant articles. Based on the different mechanisms of atherectomy, the patients were divided into mechanic atherectomy group and laser atherectomy group. The safety end points included the rate of distal embolism and severe arterial wall injuries. And the efficacy end points included primary patency rate and freedom from target vessel revascularization (TVR-free) 6 months and 12 months after surgery. A total of 9 studies and 620 patients (published between 2006 and 2014) were accepted. The rate of distal embolism was 4.2% (95% confidence interval (CI): 1.7%-6.7%), while that of severe arterial wall injuries was 1.9% (95%CI: 0.9%-3.0%), respectively. Laser atherectomy was responsible for more distal embolism (6.8%) compared to mechanic atherectomy (2.0%), which was significantly different (Q=21.66, P=0.010). At 6-month follow-up, primary patency rate and rate of TVR-free were 63.0% (95% CI: 55.5%-70.6%) and 80.4% (95% CI: 70.5%-90.3%), while at 12-month follow-up were 43.5% (95%CI: 32.2%-54.9%) and 58.0% (95% CI: 52.1%-63.9%), respectively. The free-TVR rate at 6 months follow-up in mechanical atherectomy group was 77.9%, and was inferior to that in laser atherectomy group (80.8%, Q=13.49, P=0.009). Published bias was discovered at the analysis of 12-month TVR-free rate by means of Begg Test (P=0.039). Meta analysis concerned about the 3 randomized controlled trials demonstrated that there was no significant improvement using atherectomy for ISR comparing to standard balloon at 6-month TVR-free rate (OR=1.34, 95% CI: 0.86-2.07, P=0.196). To treat ISR lesion in lower extremities, laser atherectomy has a lower free-TVR rate in the middle term follow-up.A higher rate of distal embolism is noted though. On

  9. Results of a randomized clinical trial of external beam radiation to prevent restenosis after superficial femoral artery stenting.

    Science.gov (United States)

    Therasse, Eric; Donath, David; Elkouri, Stéphane; Lespérance, Jacques; Giroux, Marie-France; Oliva, Vincent L; Guertin, Marie-Claude; Bouchard, Louis; Perreault, Pierre; Gilbert, Patrick; Soulez, Gilles

    2016-06-01

    The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage study

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil

    2011-01-01

    Background. Percutaneous coronary intervention (PCI) with implantation of a metal stent is a common procedure performed in patients with symptomatic ischaemic heart disease. Intracoronary stents typically have a backbone of stainless steel, which contains nickel, chromium, and molybdenum, and it ......Background. Percutaneous coronary intervention (PCI) with implantation of a metal stent is a common procedure performed in patients with symptomatic ischaemic heart disease. Intracoronary stents typically have a backbone of stainless steel, which contains nickel, chromium, and molybdenum......, and it remains unclear whether individuals who are allergic to these metals have an increased risk of restenosis after PCI with stent implantation. Objectives. To further evaluate whether dermatitis patients with nickel and/or chromium allergy had an increased risk of developing cardiac in-stent restenosis...... with stainless steel stents. Methods. An individual-level linkage study was performed to identify dermatitis patients who had been patch tested with the European baseline series between 1979 and 2007 at Gentofte University Hospital (N = 18794) and who had also undergone PCI at some point in a Danish hospital...

  11. A new kind of 32P stent used for prevention of the restenosis after PTCA in rabbit iliac arteries

    International Nuclear Information System (INIS)

    Gao Dongsheng; Chen Runfen; Mao Jialiang; Huang Dingjiu

    2003-01-01

    Objective: To evaluate the effect and the mechanism of a new kind of 32 P stents used for prevention of the restenosis after percutaneous transluminal coronary angioplasty (PTCA); to observe the 'edge effect' caused by radioactive stents. Methods: Six 32 P-β-emitting stents made by compound plating, paired with 6 31 P nonradioactive(control) stents, were placed separately, one in one iliac artery in 6 rabbits, respectively. Animals were sacrificed after 30 d. Angiography, morphometry and immunohistochemistry work-up were performed. Results: There were no aneurysm or thrombosis in the arteries with stents placed. Morphometric measurements demonstrated that the mean minimum lumen diameter (MLD) was greater in 32 P stents than that in control stents (P 32 P stents was greater than that in control stents, but the later had marked neointimal area than the former (P 32 P-β-emitting stents made by compound plating could prevent in-stent restenosis significantly by inhibiting the neointimal growth even with low radioactivity; and it is safe, cheap and easy to make. But an unexpected increase in neointimal response, the so-called 'edge effect', was observed in the study

  12. Coronary In-Stent Restenosis: Assessment with Corrected Coronary Opacification Difference across Coronary Stents Measured with CT Angiography.

    Science.gov (United States)

    Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph

    2015-05-01

    To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.

  13. Clinical presentation and outcomes of coronary in-stent restenosis across 3-stent generations.

    Science.gov (United States)

    Magalhaes, Marco A; Minha, Sa'ar; Chen, Fang; Torguson, Rebecca; Omar, Al Fazir; Loh, Joshua P; Escarcega, Ricardo O; Lipinski, Michael J; Baker, Nevin C; Kitabata, Hironori; Ota, Hideaki; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-12-01

    Clinical presentation of bare metal stent in-stent restenosis (ISR) in patients undergoing target lesion revascularization is well characterized and negatively affects on outcomes, whereas the presentation and outcomes of first- and second-generation drug-eluting stents (DESs) remains under-reported. The study included 909 patients (1077 ISR lesions) distributed as follows: bare metal stent (n=388), first-generation DES (n=425), and second-generation DES (n=96), categorized into acute coronary syndrome (ACS) or non-ACS presentation mode at the time of first target lesion revascularization. ACS was further classified as myocardial infarction (MI) and unstable angina. For bare metal stent, first-generation DES and second-generation DES, ACS was the clinical presentation in 67.8%, 71.0%, and 66.7% of patients, respectively (P=0.470), whereas MI occurred in 10.6%, 10.1%, and 5.2% of patients, respectively (P=0.273). The correlates for MI as ISR presentation were current smokers (odds ratio, 3.02; 95% confidence interval [CI], 1.78-5.13; Ppresentations had an independent effect on major adverse cardiac events (death, MI, and re-target lesion revascularization) at 6 months (MI versus non-ACS: adjusted hazard ratio, 4.06; 95% CI, 1.84-8.94; Pclinical presentation is similar irrespective of stent type. MI as ISR presentation seems to be associated with patient and not device-related factors. ACS as ISR presentation has an independent effect on major adverse cardiac events, suggesting that ISR remains a hazard and should be minimized. © 2014 American Heart Association, Inc.

  14. Genetic variants in CCNB1 associated with differential gene transcription and risk of coronary in-stent restenosis

    NARCIS (Netherlands)

    Silvestre-Roig, Carlos; Fernández, Patricia; Mansego, María L.; van Tiel, Claudia M.; Viana, Rosa; Anselmi, Chiara Viviani; Condorelli, Gianluigi; de Winter, Robbert J.; Martín-Fuentes, Paula; Solanas-Barca, María; Civeira, Fernando; Focaccio, Amelia; de Vries, Carlie J. M.; Chaves, Felipe Javier; Andrés, Vicente

    2014-01-01

    The development of diagnostic tools to assess restenosis risk after stent deployment may enable the intervention to be tailored to the individual patient, for example, by targeting the use of drug-eluting stent to high-risk patients, with the goal of improving safety and reducing costs. The CCNB1

  15. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p 1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  17. Distinctive effects of CD34- and CD133-specific antibody-coated stents on re-endothelialization and in-stent restenosis at the early phase of vascular injury

    Science.gov (United States)

    Wu, Xue; Yin, Tieying; Tian, Jie; Tang, Chaojun; Huang, Junli; Zhao, Yinping; Zhang, Xiaojuan; Deng, Xiaoyan; Fan, Yubo; Yu, Donghong; Wang, Guixue

    2015-01-01

    It is not clear what effects of CD34- and CD133-specific antibody-coated stents have on re-endothelialization and in-stent restenosis (ISR) at the early phase of vascular injury. This study aims at determining the capabilities of different coatings on stents (e.g. gelatin, anti-CD133 and anti-CD34 antibodies) to promote adhesion and proliferation of endothelial progenitor cells (EPCs). The in vitro study revealed that the adhesion force enabled the EPCs coated on glass slides to withstand flow-induced shear stress, so that allowing for the growth of the cells on the slides for 48 h. The in vivo experiment using a rabbit model in which the coated stents with different substrates were implanted showed that anti-CD34 and anti-CD133 antibody-coated stents markedly reduced the intima area and restenosis than bare mental stents (BMS) and gelatin-coated stents. Compared with the anti-CD34 antibody-coated stents, the time of cells adhesion was longer and earlier present in the anti-CD133 antibody-coated stents and anti-CD133 antibody-coated stents have superiority in re-endothelialization and inhibition of ISR. In conclusion, this study demonstrated that anti-CD133 antibody as a stent coating for capturing EPCs is better than anti-CD34 antibody in promoting endothelialization and reducing ISR. PMID:26813006

  18. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    Science.gov (United States)

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study

  19. In-Stent Restenosis of Drug-Eluting Stents Compared With a Matched Group of Patients With De Novo Coronary Artery Stenosis.

    Science.gov (United States)

    Buchanan, Kyle D; Torguson, Rebecca; Rogers, Toby; Xu, Linzhi; Gai, Jiaxiang; Ben-Dor, Itsik; Suddath, William O; Satler, Lowell F; Waksman, Ron

    2018-03-13

    Drug-eluting stents (DES) significantly reduced the incidence of in-stent restenosis (ISR). However, ISR still exists in the contemporary DES era. Previously deemed to be a benign process, ISR leads to complex presentation and intervention. This study aimed to compare the presentation and outcome of DES-ISR versus de novo lesions. We performed a retrospective analysis of 11,666 patients receiving percutaneous coronary intervention from 2003 to 2017 and divided them into 2 groups by de novo stenosis and ISR. They were matched based on common cardiovascular risk factors at a 4:1 ratio, respectively. After matching, a total of 1,888 patients with 3,126 de novo lesions and 472 patients with 508 ISR lesions were analyzed. Patients with ISR presented more often with unstable angina (61% vs 45%, p stent technique and should motivate the continued development of fully bioresorbable scaffolds. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.

    Science.gov (United States)

    Nakamura, M; Yock, P G; Bonneau, H N; Kitamura, K; Aizawa, T; Tamai, H; Fitzgerald, P J; Honda, Y

    2001-05-01

    Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard stent deployment techniques. The vessel volume (VV), lumen volume (LV), and volume bordered by the stent (SV) were measured using Simpson's method. The volume of plaque and neointima outside the stent (peri-stent volume, PSV) and volume of neointima within the stent (intrastent volume) were also measured. The change of each parameter during the follow-up period (follow-up minus poststent) was calculated and then divided by SV to normalize these values (designated as percent change [%]). As expected, %PSV directly correlated with %VV (Pexterior to a coronary stent occurs to a variable degree after stent implantation. There is a distinct trade-off between positive remodeling and in-stent hyperplasia: in segments in which the degree of peri-stent remodeling is less, intrastent neointimal proliferation is greater and accompanied by more significant late lumen loss.

  1. Experimental 16-row CT evaluation of in-stent restenosis using new stationary and moving cardiac stent phantoms: experimental examination

    International Nuclear Information System (INIS)

    Yamamura, J.; Adam, G.; Begemann, P.G.; Stevendaal, U. van; Grass, M.; Koester, R.

    2006-01-01

    Purpose: The aim of this study was to evaluate in-stent restenosis using a newly developed stationary and moving cardiac stent phantom with three built-in artificial stenoses and a 16-row MDCT. Materials and Methods: A newly developed coronary stent phantom with three artificial stenoses - low (approx. 30%), medium (approx. 50%) and high (approx. 70%) - was attached to a moving heart phantom and used to evaluate the ability of 16-row MDCT to visualize in-stent restenosis. High resolution scans (16 x 0.75 mm, 250 mm FOV) were made to identify the baseline for image quality. The non-moving phantom was scanned (16 x 0.75 mm, routine cardiac scan protocol) first without and then with implementation of an ECG signal at various simulated heart rates (HR 40 to 120 bpm) and pitches (0.15 to 0.3). The moving cardiac phantom was scanned at the same simulated heart rates but at a pitch of 0.15. Images were reconstructed at every 10% of the RR interval using a multi-cycle real cone-beam reconstruction algorithm. Multi-planar reformations (MPR) were made for the image evaluation. The image quality was assessed using a three-point scale, and stent patency and stenoses detection were evaluated using a four-point scale. To evaluate the image quality and to grade the stent stenoses, the median values were calculated while considering the reconstruction interval. Results: The image quality for the static phantom was adequate in 97% of the measurements. In this phantom, every stenosis was detected independent of the pitch and heart rate used. The dynamic stent phantom yielded the best results at 0%, 40%, and 50% of the RR interval at a pitch of 0.15. The low stenosis was visible at a simulated heart rate of up to 80 bpm. Patency can be detected at heart rates greater than 80 bpm. (orig.)

  2. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  3. Directional atherectomy for treatment of restenosis within coronary stents: clinical, angiographic and histologic results

    NARCIS (Netherlands)

    B.H. Strauss (Bradley); V.A.W.M. Umans (Victor); R-J. van Suylen (Robert-Jan); P.J. de Feyter (Pim); J. Marco (Jean); G. Robertson; J. Renkin; G.R. Heyndrickx (Guy); V.D. Vuzevski (Vojislav); F.T.B. Bosman (Fré); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractAbstract OBJECTIVES: The safety and long-term results of directional coronary atherectomy in stented coronary arteries were determined. In addition, tissue studies were performed to characterize the development of restenosis. METHODS: Directional coronary atherectomy was performed in

  4. Relationship of serum S1P and HC-II levels with vasoactive substances and cytokines in patients with cerebral vascular restenosis after stent implantation

    Directory of Open Access Journals (Sweden)

    Yong Liu

    2017-04-01

    Full Text Available Objective: To study the relationship of serum sphingosine 1-phosphate (S1P and heparin cofactor II (HCII levels with vasoactive substances and cytokines in patients with cerebral vascular restenosis after stent implantation. Methods: 52 patients who received cerebrovascular stent implantation and developed restenosis in our hospital between May 2012 and December 2015 were collected as observation group, and 40 healthy patients with cerebrovascular stent implantation who had re-examination in our hospital during the same period were selected as control group. ELISA method was used to detect serum S1P and HC-II levels as well as vasoactive substance and inflammatory factor contents. Spearman correlation analysis was used to evaluate the relationship of serum S1P and HC-II levels with vasoactive substances and inflammatory factors. Results: Serum S1P and HC-II levels of observation group were lower than those of control group (P<0.05; serum vasoactive substances endothelin (ET, angiotensin II (AngII and thromboxane B2 (TXB2 contents of observation group were higher than those of control group while nitric oxide (NO content was lower than that of control group (P<0.05; serum inflammatory factors hypersensitive C-reactive protein (hs-CRP, interleukin-1 (IL-1, IL-6, IL-8 and IL-11 contents of observation group were higher than those of control group (P<0.05. Serum S1P and HC-II levels in patients with cerebral vascular restenosis after stent implantation were directly correlated with vasoactive substance and inflammatory factor contents. Conclusion: Serum S1P and HC-II levels decrease in patients with cerebral vascular restenosis after stent implantation, and it is an important cause of cerebral vascular dysfunction and systemic inflammatory response.

  5. Restenosis in coronary bare metal stents. Importance of time to follow-up: a comparison of coronary angiograms 6 months and 4 years after implantation

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Helqvist, Steffen; Kløvgaard, Lene

    2008-01-01

    Objectives. Angiographic late lumen loss measured 6 to 9 month after bare metal stent implantation in the coronary arteries is a validated restenosis parameter. Design. We performed a second angiographic follow-up after 4 years in event free survivors from the DANSTENT trial cohort. Results......-sectional vessel area and a 39% reduction of the binary restenosis rate over time. Conclusions. Instent late lumen loss in bare metal stents decreases spontaneously over time. Maturation of early hyperplastic tissue reaction after stent implantation with subsequent thinning of fibrotic tissue might explain...

  6. Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model

    Science.gov (United States)

    Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun

    2018-01-01

    Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643

  7. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  8. Restenosis of the sigmoid sinus after stenting for treatment of intracranial venous hypertension: case report

    International Nuclear Information System (INIS)

    Tsumoto, T.; Miyamoto, T.; Shimizu, M.; Inui, Y.; Nakakita, K.; Hayashi, S.; Terada, T.

    2003-01-01

    We report what we believe to be the first case of restenosis of the sigmoid sinus after stenting, in a 42-year-old man with an arteriovenous malformation with progressive right hemiparesis secondary to venous hypertension. Angiography revealed severe stenosis of the left sigmoid sinus, which was dilated with a self-expandable stent. Six months after the procedure, however, the sinus was again severely stenosed. Intravascular sonography revealed intimal proliferation in the stented sinus. It was dilated percutaneously, and the venous pressure decreased from 51 to 33 mmHg. On sonography, the intimal tissue decreased in thickness and the diameter of the stent enlarged a little. (orig.)

  9. Restenosis of the sigmoid sinus after stenting for treatment of intracranial venous hypertension: case report

    Energy Technology Data Exchange (ETDEWEB)

    Tsumoto, T.; Miyamoto, T.; Shimizu, M.; Inui, Y.; Nakakita, K.; Hayashi, S. [Department of Neurosurgery, Minami Wakayama National Hospital, Wakayama (Japan); Terada, T. [Department of Neurological Surgery, Wakayama Medical University, Wakayama (Japan)

    2003-12-01

    We report what we believe to be the first case of restenosis of the sigmoid sinus after stenting, in a 42-year-old man with an arteriovenous malformation with progressive right hemiparesis secondary to venous hypertension. Angiography revealed severe stenosis of the left sigmoid sinus, which was dilated with a self-expandable stent. Six months after the procedure, however, the sinus was again severely stenosed. Intravascular sonography revealed intimal proliferation in the stented sinus. It was dilated percutaneously, and the venous pressure decreased from 51 to 33 mmHg. On sonography, the intimal tissue decreased in thickness and the diameter of the stent enlarged a little. (orig.)

  10. The experimental study of 32P and diallyl trisulfide coating stent for inhibiting neointimal hyperplasia in a canine model of coronary restenosis

    International Nuclear Information System (INIS)

    Xu Shanghua; Jiang Hong; Li Gengshan; Jiang Xuejun; Li Xiaoyan; Chen Yuanxiu; Wang Hairong; Wu Kegui; Nie Xiaomin

    2004-01-01

    Objective: To assesses the efficiency of 32 P and diallyl trisulfide (DT)-coated coronary stents on neointimal proliferation in a canine model of restenosis. Methods: 32 P (740 kBq/stent), DT (210 μg/stent) alone and jointly coated stents were deployed with mild oversizing in both the left circumflex coronary artery (LCX) and the left anterior descending coronary artery (LAD) of 10 dogs. The implantation of protein-coated stents was used as the control. The therapeutic effect was assessed 6 months after the intervention. The dogs were sacrificed and the vessels were excised. For morphologic examinations the tissue sections were stained with HE and Van Gieson. Results: Compared with the control stents, the neointimal area reduced in stents coated with 32 P, DT alone and 32 P+DT [ 32 P: (2.63±0.48) mm 2 , DT: (2.50±0.49) mm 2 , 32 P+DT: (1.42±0.41) mm 2 vs control group: (4.87±0. 80) mm 2 , P=0.001]. 32 P+DT was more effective than either of them alone for reducing the neointimal area (P≤0.005). Both jointly and alone coated stents of 32 P, DT decreased the percent area stenosis [ 32 P: (32.48±4.79)%, DT: (30.04±5.43)%, 32 P+DT: (17.21±4.05)% vs control group: (54.62±6.82)%, P 32 P+DT group compared with 32 P or DT-coated stents group (P≤0.001). Angiographic restenosis (diameter stenosis) was lighter in stents coated with 32 P, DT and 32 P+DT compared with control stents (P 32 P+DT was more effective than 32 P or DT alone for reducing diameter stenosis (P≤0.005). No evidence of 'edge effect' was seen in adjacent, nonstented coronary segments. Conclusion: Coronary stents coated with 32 P plus DT produced a significantly reduced neointimal hyperplasia and restenosis rate in the canine LCX and LAD 6 months after stents implantation

  11. Diagnostic value of microRNA-143 in predicting in-stent restenosis for patients with lower extremity arterial occlusive disease

    OpenAIRE

    Yu, Zhi-Hai; Wang, Hai-Tao; Tu, Can

    2017-01-01

    Purpose This study was conducted to explore the diagnostic value of microRNA-143 (miRNA-143) in predicting in-stent restenosis (ISR) of lower extremity arterial occlusive disease (LEAOD). Methods From February 2012 to March 2015, 165 patients (112 males and 53 females) with LEAOD undergoing interventional treatment were enrolled in this study. Serum miRNA-143 expression was detected using quantitative real-time polymerase chain reaction (qRT-PCR). Patients were assigned into the restenosis an...

  12. A Phase II study of external-beam radiotherapy and endovascular brachytherapy with PTA and stenting for femoropopliteal artery restenosis

    International Nuclear Information System (INIS)

    Narayan, Kailash; Denton, Michael; Das, Ram; Bernshaw, David; Rolfo, Aldo; Dyk, Sylvia van; Mirakian, Alex

    2006-01-01

    Purpose: To assess the safety and seek evidence of efficacy of combined external-beam radiotherapy (EBRT) and endovascular brachytherapy in the treatment of stenotic vascular lesions. Methods and Materials: Seventeen patients with high risk for restenosis of femoropopliteal arteries were enrolled in this study from February 2000 to August 2002. The external beam radiotherapy regimen consisted of 10 Gy in 5 fractions of 2 Gy, starting on Day 0. This was followed on Day 6 by angiography, stent placement, and intraluminal brachytherapy to a dose of 10 Gy at 1.2 mm from stent surface. The EBRT was continued from the same day to another 10 Gy in 2 Gy daily fractions for 5 days. Results: The follow up ranged from 33 months to 60 months. At the time of analysis 15 of 17 patients were alive with patent stents. Of these, 10 were symptom-free. Two patients died of unrelated causes. Conclusions: The combination of EBRT and endovascular brachytherapy provided adequate dose distribution without any geographical miss or 'candy wrapper' restenosis. No incidence of aneurysmal dilation of radiated vascular segment was observed. The treatment was feasible, well tolerated, and achieved 88% stenosis free survival

  13. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  14. Novel Use of an Orbital Atherectomy Device for In-Stent Restenosis: Lessons Learned

    Directory of Open Access Journals (Sweden)

    K. Shaikh

    2016-01-01

    Full Text Available We present a case of a 67-year-old man with stage III chronic kidney disease, uncontrolled diabetes mellitus, coronary artery disease, and high surgical risk who presented with two episodes of acute coronary syndrome attributed to in-stent restenosis (ISR associated with heavily calcified lesions. In this case, we were able to improve luminal patency with orbital atherectomy system (OAS; however, withdrawal of the device resulted in a device/stent interaction, causing failure of the device. Given limitations in current evidence and therapies, managing ISR can be a technical and cognitive challenge. Balloon expansion of the affected region often provides unsatisfactory results, possibly related to significant calcium burden. OAS could be an efficacious way of reestablishing luminal patency in ISR lesions, as these lesions are often heavily calcified.

  15. Incidence and classification of neointimal proliferation and in-stent restenosis in post-stenting patients at 1-year interval: Findings from non-invasive coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Nan, E-mail: southmuch@hotmail.com [Department of Radiology, East Hospital, Tongji University School of Medicine, No. 150, Jimo Road, Shanghai 200120 (China); Zhang, Jiayin, E-mail: andrewssmu@msn.com [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Li, Minghua, E-mail: drliminghua@gmail.com [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Pan, Jingwei, E-mail: drpanjingwei@gmail.com [Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Lu, Zhigang, E-mail: drluzhigang@gmail.com [Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China)

    2014-10-15

    Highlights: • The incidence of silent in-stent restenosis at 1-year as revealed by CT is 7.6%. • The incidence of neointimal proliferation at 1-year as revealed by CT is 12.6%. • Diabetes are associated with higher incidence of neointimal proliferation. - Abstract: Objectives: To evaluate the incidence of coronary in-stent restenosis (ISR) and neointimal proliferation by coronary CT angiography (CCTA) at 1-year follow-up in asymptomatic patients. Methods: 234 patients (mean age: 67 ± 10.2 years, range 39–88 years, 180 males and 54 females) with 379 stents were prospectively enrolled in this study. Binary ISR was classified by CCTA into 4 types using Mehran classification. Neointimal proliferation was similarly classified into focal and diffuse types. All patients with CCTA-revealed ISR or neointimal proliferation underwent further invasive coronary angiography (ICA) for validation. Fisher's exact test was used for comparison. Results: ICA revealed patent stents with neointimal proliferation in 39 patients (16.7%, 39/234) and binary ISR in 23 patients (9.8%, 23/234). Lesion-based analysis showed 12 type I ISR lesions, 4 type II ISR lesions, 1 type III ISR lesion and 7 type IV ISR lesions. Among cases with neointimal proliferation, 27 lesions were classified as focal type whereas 13 lesions were classified as diffuse type. Patients with diabetes mellitus were associated with higher incidence of CCTA-revealed neointimal proliferation (21/77 vs. 18/157, p = 0.002) as well as ISR (12/77 vs. 11/157, p = 0.038), compared to patients without diabetes. CCTA was found to have good diagnostic performance for neointimal proliferation and ISR detection as well as classification, with an overall accuracy of 84.4% (54/64). Conclusions: Silent ISR as well as neointimal proliferation is not uncommon findings in asymptomatic post-stenting patients at 1-year interval, as revealed by CCTA. Patients with diabetes are prone to have higher incidence of neointimal

  16. [A Case of Peritoneal Metastasis in Which Colostomy Was Useful for Restenosis after Stenting].

    Science.gov (United States)

    Tagawa, Hiroko; Yoshimatsu, Kazuhiko; Yokomizo, Hajime; Yano, Yuki; Nakayama, Mao; Okayama, Sachiyo; Satake, Masaya; Sakuma, Akiko; Matsumoto, Atsuo; Fujimoto, Takashi; Shiozawa, Shunichi; Shimakawa, Takeshi; Katsube, Takao; Kato, Hiroyuki; Naritaka, Yoshihiko

    2015-11-01

    We report a case of restenosis after performing stenting twice for ileus caused by peritoneal dissemination that occurred after surgery for sigmoid colon cancer, in which colostomy was performed to improve the patient's QOL. The patient was a 58-year-old woman who underwent sigmoidectomy for sigmoid colon cancer. She presented with a peritoneal recurrence 3 times, and the third surgery was a non-curative resection. Chemotherapy was administered but was discontinued because of severe adverse events, and the patient was followed up with the best supportive care. An anastomotic stricture occurred 4 years after the initial surgery, and despite performing stenting twice, stenosis occurred 3 times within a few months. The third stenosis occurred shortly after the second episode, and colostomy was therefore performed. The patient died from cancer 4 months after colostomy without having another episode of stenosis. Although stenting is effective for patients with malignant colon stenosis, colostomy appears to be more effective for repeated post-stenting stenosis, when the patient is in an eligible general condition.

  17. Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun; Fujioka, Chikako; Kiguchi, Masao; Kohno, Shingo [Hiroshima University Hospital, Department of Clinical Radiology, Hiroshima (Japan); Yamamoto, Hideya; Kitagawa, Toshiro [Hiroshima University, Department of Molecular and Internal Medicine, Division of Clinical Medical Science, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan); Ito, Katsuhide [Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan)

    2009-10-15

    The purpose of this study was to compare coronary 64-slice CT angiography (CTA) protocols, specifically prospective electrocardiograph (ECG)-triggered and retrospective ECG-gated CT acquisition performed using a tube voltage of 140 kV and 120 kV, regarding intracoronary stent imaging. Coronary artery stents (n=12) with artificial in-stent restenosis (50% luminal reduction, 40 HU) on a cardiac phantom were examined by CT at heart rates of 50-75 beats per minute (bpm). The subjective visibility of in-stent restenosis was evaluated with a three-point scale (1 clearly visible, 2 visible, and 3 not visible), and artificial lumen narrowing [(inner stent diameter - measured lumen diameter)/inner stent diameter], lumen attenuation increase ratio [(in-stent attenuation - coronary lumen attenuation)/coronary lumen attenuation], and signal-to-noise ratio of in-stent lumen were determined. The effective dose was estimated. The artificial lumen narrowing (mean 43%), the increase of lumen attenuation (mean 46%), and signal-to-noise ratio (mean 7.8) were not different between CT acquisitions (p=0.12-0.91). However, the visibility scores of in-stent restenosis were different (p<0.05) between ECG-gated CTA techniques: (a) 140-kV prospective (effective dose 4.6 mSv), 1.6; (b) 120-kV prospective (3.3 mSv), 1.8; (c) 140-kV retrospective (16.4-18.8 mSv), 1.9; and (d) 120-kV retrospective (11.0-13.4 mSv), 1.9. Thus, 140-kV prospective ECG-triggered CTA improves coronary in-stent restenosis visibility at a lower radiation dose compared with retrospective ECG-gated CTA. (orig.)

  18. Restenosis Prevention Using Photon External Beam Radiation

    International Nuclear Information System (INIS)

    Goldstein, M.

    2002-01-01

    During transluminal coronary angioplasty, the balloon procedure is designed to crush the plaque and to support the weakened arterial wall by using the stent (an expandable metallic mesh). This procedure often tears the arterial wall as well. Some of the cells in the blood vessel respond to this injury by initiating repair which often leads to restenosis (reclosing) of the artery. In many cases restenosis occur despite the stent which become incorporated into the poliferative tissue that form around the lesion. But if the lesion is treated with radiation (8-30 Gy) the restenosis effect is inhibited. In this paper, the Adjoint Monte Carlo (AMC) method is used for external radiation treatment planning of the stent volume (the volume covered by the stent during a full cardiac cycle), while minimizing the damage to the organs at risk (OAR) and surrounding healthy tissue

  19. A Mechanobiological model for damage-induced growth in arterial tissue with application to in-stent restenosis

    Science.gov (United States)

    Fereidoonnezhad, B.; Naghdabadi, R.; Sohrabpour, S.; Holzapfel, G. A.

    In-stent restenosis (ISR) is one of the main drawbacks of stent implementation which limits the long-term success of the procedure. Morphological changes occurring within the arterial wall due to stent-induced mechanical injury are a major cause for activation of vascular smooth muscle cells (VSMCs), and the subsequent development of ISR. Considering the theory of volumetric mass growth and adopting a multiplicative decomposition of the deformation gradient into an elastic part and a growth part, we present a mechanobiological model for ISR. An evolution equation is developed for mass growth of the neointima, in which the activation of VSMCs due to stent-induced damage (injury) and the proliferation rate of the activated cells are considered. By introducing the mass evolution into the mass balance equation, we obtain the evolution of the growth tensor over time. The model is implemented in a finite element code and the procedure of angioplasty is simulated, whereby the features of the proposed growth model are illustrated.

  20. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  1. Meta-Analysis of Randomized Clinical Trials Comparing Biodegradable Polymer Drug-Eluting Stent to Second-Generation Durable Polymer Drug-Eluting Stents.

    Science.gov (United States)

    El-Hayek, Georges; Bangalore, Sripal; Casso Dominguez, Abel; Devireddy, Chandan; Jaber, Wissam; Kumar, Gautam; Mavromatis, Kreton; Tamis-Holland, Jacqueline; Samady, Habib

    2017-03-13

    The authors sought to perform a meta-analysis of randomized clinical trials (RCTs) comparing the safety and efficacy of biodegradable polymer drug-eluting stents (BP-DES) to second-generation durable polymer drug-eluting stents (DP-DES). Prior meta-analyses have established the superiority of BP-DES over bare-metal stents and first-generation DP-DES; however, their advantage compared with second-generation DP-DES remains controversial. The authors searched PubMed and Scopus databases for RCTs comparing BP-DES to the second-generation DP-DES. Outcomes included target vessel revascularization (TVR) as efficacy outcome and cardiac death, myocardial infarction (MI), and definite or probable stent thrombosis (ST) as safety outcomes. In addition, we performed landmark analysis for endpoints beyond 1 year of follow-up and a subgroup analysis based on the stent characteristics. The authors included 16 RCTs comprising 19,886 patients in the meta-analysis. At the longest available follow-up (mean duration 26 months), we observed no significant differences in TVR (p = 0.62), cardiac death (p = 0.46), MI (p = 0.98), or ST (risk ratio: 0.83, 95% confidence interval: 0.64 to 1.09; p = 0.19). Our landmark analysis showed that BP-DES were not associated with a reduction in the risk of very late ST (risk ratio: 0.87, 95% confidence interval: 0.49 to 1.53; p = 0.62). Similar outcomes were seen regardless of the eluting drug (biolimus vs. sirolimus), the stent platform (stainless steel vs. alloy), the kinetics of polymer degradation or drug release (6 months), the strut thickness of the BP-DES (thin 100 μm), or the DAPT duration (≥6 months vs. ≥12 months). BP-DES have similar safety and efficacy profiles to second-generation DP-DES. Published by Elsevier Inc.

  2. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  3. Clinical effectiveness of secondary interventions for restenosis after renal artery stenting

    Science.gov (United States)

    Simone, Thomas A.; Brooke, Benjamin S.; Goodney, Philip P.; Walsh, Daniel B.; Stone, David H.; Powell, Richard J.; Cronenwett, Jack L.; Nolan, Brian W.

    2013-01-01

    Objective Secondary interventions for renal artery restenosis (RAS) after renal artery stenting are common, despite limited data about their effectiveness. This study was designed to evaluate the outcomes of endovascular treatment of recurrent RAS. Methods We conducted a retrospective review of patients who underwent renal artery stenting between 2001 and 2011 at Dartmouth-Hitchcock Medical Center. Patients who required secondary interventions were compared with control patients who underwent only primary interventions for RAS. Multivariate regression models were used to identify factors associated with successful outcomes, as measured by changes in blood pressure, estimated glomerular filtration rate, and number of antihypertensive medications required. Results Sixty-five secondary (57 patients) renal interventions were undertaken for recurrent RAS associated with progressive hypertension or renal dysfunction and compared with outcomes after 216 primary (180 patients) renal artery stenting procedures. Patients undergoing primary vs secondary interventions did not differ significantly in the number of preoperative antihypertensive medications used, comorbid conditions, or blood pressure. All primary and secondary interventions were performed with stents and showed no difference in procedural complications. At a mean follow-up of 23 months (range, 1–128 months), similar improvements in renal function and blood pressure were found between patients undergoing primary and secondary interventions, and there was no difference in rates of restenosis or survival between cohorts. Regression models showed that the use of embolic protection devices was associated with improved renal function after primary (odds ratio [OR], 2.0; 95% confidence interval [CI], 1.1–3.8; P < .05) and secondary (OR, 4.7; 95% CI, 1.7–12.5; P < .05) interventions, whereas statin therapy was associated with improved renal (OR, 2.0; 95% CI, 1.3–3.2; P < .05) and blood pressure response (OR, 4

  4. Complications related to conventional self-expandable metal stent insertion and internal irradiation stent insertion in patients with advanced esophageal carcinoma: an analysis of 32 cases

    International Nuclear Information System (INIS)

    Xu Xingwen; Di Haiting; Zhu Jun; Shi Jian

    2011-01-01

    Objective: To compare the occurrence of complications between conventional self-expandable metal stent and internal irradiation stent insertion in treating patients with advanced esophageal carcinomas. Methods: A total of 32 patients with advanced esophageal carcinoma were randomly divided into irradiation stent group (n=15) and conventional stent group (n=17). Internal irradiation stent loaded with 125 I seeds was employed in patients of irradiation stent group, while conventional self-expandable metal stent was used in patients of conventional stent group. After the treatment, clinical follow-up was regularly conducted. Postoperative complications such as fever, severe chest pain, cough, esophageal perforation, pneumonia, hemorrhage, stent migration and restenosis, etc. were observed. Results: No significant difference in the occurrence of fever, severe chest pain, esophageal perforation and hemorrhage existed between the two groups (P>0.05). The difference in the occurrence of long-term complications such as stent migration or restenosis between the two groups was out statistically significant (P>0.05). However, the restenosis in irradiation stent group occurred obviously much later than that in conventional stent group. Conclusion: For the treatment of advanced esophageal carcinomas, the insertion of internal irradiation esophageal stent is safe. It dose not increase the incidence of postoperative complications. Therefore, it is worth popularizing this technique in clinical practice. (authors)

  5. Cryoplasty for the Prevention of Arterial Restenosis

    International Nuclear Information System (INIS)

    Wildgruber, Moritz G.; Berger, Hermann J.

    2008-01-01

    Restenosis after percutaneous transluminal angioplasty remains the limiting factor for the long-term benefit of endovascular therapies of peripheral arterial occlusive disease. Despite a variety of modifications and adjuncts to angioplasty such as bare metal stents, covered stents, and drug-eluting stents as well as a number of new technologies like laser angioplasty and cutting balloon angioplasty, restenosis rates have not been significantly affected and remain inferior to those for surgery for long lesions in the femoropopliteal segment. Cryoplasty, which combines balloon angioplasty with the application of cryothermal energy to the vessel wall, was suggested as a promising approach to prevent the formation of neointimal hyperplasia after angioplasty procedures. This review discusses the basic principles of cryoplasty, summarizes the current data on restenosis rates after cryoplasty treatment, and evaluates cryoplasty as a new treatment method to solve the problems associated with restenosis development. The results of the clinical studies suggest that cryoplasty is a feasible and safe technique in the treatment of femoropopliteal disease, however, they have failed to prove any superiority of cryoplasty over conventional angioplasty.

  6. Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    Science.gov (United States)

    Floren, Michael G; Günther, Rolf W; Schmitz-Rode, Thomas

    2004-05-01

    extensive necrosis area around the stent. Treatment time and stent temperature were optimized in further tests. Selective noninvasive energy transfer to coronary stainless steel stents by inductive heating is possible within a wide range of power. By thermal conduction, vital cells close to the stent struts can be affected. The frequency of 200 kHz turned out to be favorable. There is still room for further optimization of energy dosage with regard to material and stent design, to induce controlled cell death. The method has potential to serve as an alternative approach for prevention of instent restenosis.

  7. Angioplasty Guided by Intravascular Ultrasound: Meta-Analysis of Randomized Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, José Albuquerque Neto de, E-mail: jafneto@cardiol.br; Nogueira, Iara Antonia Lustosa [Universidade Federal do Maranhão, São Luiz, MA (Brazil); Figueiro, Mabel Fernandes; Buehler, Anna Maria; Berwanger, Otavio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo, SP (Brazil)

    2013-08-15

    The impact of intravascular ultrasound (IVUS) use on stenting has shown inconclusive results. Systematic review and meta-analysis of the impact of IVUS on stenting regarding the clinical and angiographic evolution. A search was performed in Medline/Pubmed, CENTRAL, Embase, Lilacs, Scopus and Web of Science databases. It included randomized clinical trials (RCTs) that evaluated the implantation of stents guided by IVUS, compared with those using angiography alone (ANGIO). The minimum follow-up duration was six months and the following outcomes were assessed: thrombosis, mortality, myocardial infarction, percutaneous and surgical revascularization, major adverse cardiovascular events (MACE) and restenosis. The binary outcomes were presented considering the number of events in each group; the estimates were generated by a random effects model, considering Mantel-Haenszel statistics as weighting agent and magnitude of effect for the relative risk (RR) with its respective 95% confidence interval (95%CI). Higgins I{sup 2} test was used to quantify the consistency between the results of each study. A total of 2,689 articles were evaluated, including 8 RCTs. There was a 27% reduction in angiographic restenosis (RR: 0.73, 95% CI: 0.54-0.97, I{sup 2} = 51%) and statistically significant reduction in the rates of percutaneous revascularization and overall (RR: 0.88; 95% CI: 0.51 to 1.53, I{sup 2} = 61%, RR: 0.73, 95% CI: 0.54 to 0.99, I{sup 2} = 55%), with no statistical difference in surgical revascularization (RR: 0.95, 95% CI: 0.52-1.74, I{sup 2} = 0%) in favor of IVUS vs. ANGIO. There were no differences regarding the other outcomes in the comparison between the two strategies. Angioplasty with stenting guided by IVUS decreases the rates of restenosis and revascularization, with no impact on MACE, acute myocardial infarction, mortality or thrombosis outcomes.

  8. Models and Analysis of Atherosclerosis, Restenosis, and Aneurysm Formation in the Mouse

    NARCIS (Netherlands)

    de Waard, Vivian; Gijbels, Marion J. J.; Lutgens, Esther; de Winther, Menno P. J.; de Vries, Carlie J. M.

    2012-01-01

    Atherosclerosis is considered a chronic inflammatory condition of the vessel wall and involves a high chronic concentration of low-density lipoprotein (LDL) in blood. In humans, restenosis develops after intravascular interventions such as angioplasty and stent placement to treat atherosclerosis,

  9. Análisis Costo Efectividad del Stent Farmacológico V/S Stent no Farmacológico en Cardiopatía Isquémica en Chile.

    Science.gov (United States)

    De la Puente, Catherine; Vallejos, Carlos; Velásquez, Mónica; Soto, David; Orellana, Juan

    2012-12-01

    To evaluate and compare the costs and effectiveness of two alternative stent, drug eluting stent (SF) and bare metal stent (SNF). Cost-utility analysis based on a Markov model using data from a cohort study of Hospital Las Higueras of Talcahuano, Chile. The effectiveness measure was the rate of restenosis and the time of restenosis. The effectiveness outcomes are expressed in quality-adjusted life years (QALY) gained. Costs are expressed in national currency 2011. The evaluation perspective was from the public heath budget. We model a cohort from age 63 to 80 years, life expectancy in Chile. Apply discount rate of 0, 3% and 6% for results and costs. Sensitivity analysis is performed according to the ranges of variability in costs, the utility values of the variables and transition between states. No differences in restenosis rates between the two stents, although there were differences in the time of restenosis. The incremental cost effectiveness ratio (ICER) no discount rate was CH$ 235.749 per QALY gained when using drug-eluting stent, the value below the equivalent of 1 Gross Domestic Product (PIB) per capita for 2011 in Chile. The drug-eluting stent (SF) is cost effective compared to bare metal stent (SNF). The ICER is not affected by the sensitivity analysis (variability of cost, utility ranges used, probability of restenosis). Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  10. Six-year clinical follow-up after treatment of diffuse in-stent restenosis with cutting balloon angioplasty followed by intracoronary brachytherapy with liquid rhenium-188-filled balloon via transradial approach

    International Nuclear Information System (INIS)

    Hang Chiling; Wu Chiungjen; Hsieh Bortsung

    2010-01-01

    Long-term follow-up studies revealed a significant decline in the benefits of intracoronary radiation for in-stent restenosis. A total of 25 study and 25 contemporaneous control patients with diffuse in-stent restenosis who underwent cutting balloon angioplasty (CBA) transradially, followed by subsequent intracoronary irradiation with a liquid β-emitter Rhenium-188 ( 188 Re)-filled balloon were enrolled in the study. The mean clinical follow-up durations were 64.9±13.0 and 66.3±13.8 months for the irradiated and control patients, respectively. Six-month angiographic restenosis was observed in 16% (4 of 25) of the patients in the irradiated group and 48% (12 of 25) of the patients in the control groups (P=0.03). The 6-month major adverse cardiac events (MACE) rate was 12% and 44%, respectively (P=0.025). The 3-year follow-up angiography was performed in 16 of 21 (76%) irradiated patients and in 4 of 13 (31%) control patients who had no significant restenosis at the 6-month angiographic follow-up. Restenosis occurred in 1 of 16 (7%) irradiated patients and 2 of 4 (50%) control patients. Late target lesion revascularization was performed in 1 irradiated and 2 control patients. The MACE rate within 6 years was significantly reduced in the irradiated group (20% vs. 56%, P=0.019). Brachytherapy using 188 Re-filled balloon following CBA for diffuse in-stent restenotic native coronary arteries is effective in reducing target lesion restenosis and improving long-term outcomes. (author)

  11. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    Science.gov (United States)

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation

    DEFF Research Database (Denmark)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian

    2017-01-01

    -stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. METHODS/RESULTS: The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability...... of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. CONCLUSION: In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt...... compared to segments treated with a DES (5.4% vs 0.76%; P15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold...

  13. Meta-analysis comparing efficacy and safety of first generation drug-eluting stents to bare-metal stents in patients with diabetes mellitus undergoing primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian

    2013-01-01

    revascularization (hazard ratio 0.42, 95% confidence interval 0.29 to 0.59, p 1 year) with DES. In conclusion, this meta-analysis, based on individual patients' data from 11 randomized trials, showed that among patients with diabetes with STEMIs who undergo primary percutaneous coronary intervention, sirolimus...... with high rates of target vessel revascularization after bare-metal stent (BMS) implantation but also higher rates of ST after DES implantation. Therefore, the aim of this study was to perform a meta-analysis of individual patients' data to evaluate the long-term safety and effectiveness of DES compared......Several concerns have emerged regarding the higher risk for stent thrombosis (ST) after drug-eluting stent (DES) implantation, especially in the setting of ST-segment elevation myocardial infarction (STEMI). Few data have been reported so far in patients with diabetes mellitus, which is associated...

  14. Timing of silicone stent removal in patients with post-tuberculosis bronchial stenosis.

    Science.gov (United States)

    Eom, Jung Seop; Kim, Hojoong; Park, Hye Yun; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung

    2013-10-01

    In patients with post-tuberculosis bronchial stenosis (PTBS), the severity of bronchial stenosis affects the restenosis rate after the silicone stent is removed. In PTBS patients with incomplete bronchial obstruction, who had a favorable prognosis, the timing of stent removal to ensure airway patency is not clear. We evaluated the time for silicone stent removal in patients with incomplete PTBS. A retrospective study examined PTBS patients who underwent stenting and removal of a silicone stent. Incomplete bronchial stenosis was defined as PTBS other than total bronchial obstruction, which had a luminal opening at the stenotic segment on bronchoscopic intervention. The duration of stenting was defined as the interval from stent insertion to removal. The study included 44 PTBS patients and the patients were grouped at intervals of 6 months according to the duration of stenting. Patients stented for more than 12 months had a significantly lower restenosis rate than those stented for less than 12 months (4% vs. 35%, P = 0.009). Multiple logistic regression revealed an association between stenting for more than 12 months and a low restenosis rate (odds ratio 12.095; 95% confidence interval 1.097-133.377). Moreover, no restenosis was observed in PTBS patients when the stent was placed more than 14 months previously. In patients with incomplete PTBS, stent placement for longer than 12 months reduced restenosis after stent removal.

  15. Usefulness of Eosinophil-Lymphocyte Ratio to Predict Stent Restenosis

    Directory of Open Access Journals (Sweden)

    Mehmet Zihni Bilik

    2016-06-01

    Full Text Available Objective: Stent restenosis (SR is an important compli­cation of percutaneous coronary intervention. There are many studies explored the relation of eosinophils with SR, however, there is no data about relationship between eo­sinophil-lymphocyte ratio (ELR and SR. In this study we aimed to investigate the relationship between the value of ELR on admission and SR. Methods: The study was included 314 patients who had been applied a coronary stent implantation and they were admitted to cardiology clinic with stabile angina and un­derwent repeat coronary angiography. The data obtained from patients were analyzed retrospectively. The patient group was consisted of 197 patients who were diagnosed as SR, and the control group was consisted of 117 pa­tients whose stents were patent angiographically. Results: The groups were similar in terms of age, gender, hypertension, diabetes mellitus, LDL-C, HDL-C, platelet count, platelet-lymphocyte ratio (PLR, hemoglobin and left ventricle ejection fraction (LVEF. White blood cell (WBC, neutrophil, eosinophil, C-reactive protein (CRP, ELR and neutrophil-lymphocyte ratio (NLR on admission were higher in the SR group compared to the controls. All patients were categorized into two groups according to ELR values and SR was more frequent in the high ELR group compared to low ELR group. An ELR value of ≥0.745 predicted SR with 64% sensitivity and 61% specif­ity. Conclusion: In this study ELR was found statistically higher in SR patients compared to the controls. Accord­ing to our data ELR as an inexpensive and easy method, may contribute to determination of high risk patients and increased ELR can be used as a predictor of SR.

  16. Evaluation of the small intestinal submucosa covered stent in preventing restenosis after percutaneous transluminal angioplasty in the swine

    International Nuclear Information System (INIS)

    Wang Xiaobai; Li Jinglei; Zhang Hong; Zhang Yan

    2012-01-01

    Objective: To compare the performance of small intestinal submucosa (SIS)-covered endografts (SCEs) to bare nitinol stents (BSs) in injured swine iliac arteries. Materials and methods: Twenty-eight nitinol stents were used: 14 externally SCEs and 14 BSs. Devices were implanted in each side of balloon-injured external iliac arteries of 14 swine via carotid approach. Arteriograms were obtained before and after implantation and before animal sacrifice at 4, 8, and 12 weeks. Histopathological and electron microscopy studies of explanted specimens were performed. Results: Implantation of all SCEs and BSs was technically successful, but one SCE and one BS were obstructed at 8 weeks after implantation. At sacrifice, the other 26 stents were patent, with angiogram showing no significant different luminal narrowing between SCEs and BSs. Proliferating cell nuclear antigen (PCNA) immunohistochemistry examination revealed that the percentage of PCNA(+) cells were lower in SCEs (p < 0.05). Additionally, histomorphological analysis indicated that the neointima area and percentage of narrowing area were greater in SCEs, but there was no statistical significance. Greater endothelial cell count in SCEs than in BSs per visual field at 4000 times magnification by scanning electron microscope (p < 0.05). Conclusion: Compared to BSs, no definite decrease of neointima and restenosis was found in SCEs in the present study. However, it is effective in promoting endothelial regeneration and strengthening endothelial function.

  17. iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Malvankar-Mehta, Monali S; Chen, Yufeng Nancy; Iordanous, Yiannis; Wang, Wan Wendy; Costella, John; Hutnik, Cindy M L

    2015-01-01

    Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of

  18. Timing of silicone stent removal in patients with post-tuberculosis bronchial stenosis

    Directory of Open Access Journals (Sweden)

    Jung Seop Eom

    2013-01-01

    Full Text Available Context: In patients with post-tuberculosis bronchial stenosis (PTBS, the severity of bronchial stenosis affects the restenosis rate after the silicone stent is removed. In PTBS patients with incomplete bronchial obstruction, who had a favorable prognosis, the timing of stent removal to ensure airway patency is not clear. Aims: We evaluated the time for silicone stent removal in patients with incomplete PTBS. Settings and Design: A retrospective study examined PTBS patients who underwent stenting and removal of a silicone stent. Methods: Incomplete bronchial stenosis was defined as PTBS other than total bronchial obstruction, which had a luminal opening at the stenotic segment on bronchoscopic intervention. The duration of stenting was defined as the interval from stent insertion to removal. The study included 44 PTBS patients and the patients were grouped at intervals of 6 months according to the duration of stenting. Results: Patients stented for more than 12 months had a significantly lower restenosis rate than those stented for less than 12 months (4% vs. 35%, P = 0.009. Multiple logistic regression revealed an association between stenting for more than 12 months and a low restenosis rate (odds ratio 12.095; 95% confidence interval 1.097-133.377. Moreover, no restenosis was observed in PTBS patients when the stent was placed more than 14 months previously. Conclusions: In patients with incomplete PTBS, stent placement for longer than 12 months reduced restenosis after stent removal.

  19. Esophageal Stent for Refractory Variceal Bleeding: A Systemic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Shao

    2016-01-01

    Full Text Available Background. Preliminary studies suggest that covered self-expandable metal stents may be helpful in controlling esophageal variceal bleeding. Aims. To evaluate the effectiveness and safety of esophageal stent in refractory variceal bleeding in a systematic review and meta-analysis. Methods. A comprehensive literature search was conducted on PubMed, EMBASE, and Cochrane Library covering the period from January 1970 to December 2015. Data were selected and abstracted from eligible studies and were pooled using a random-effects model. Heterogeneity was assessed using I2 test. Results. Five studies involving 80 patients were included in the analysis. The age of patients ranged from 18 to 91 years. The mean duration of follow-up was 46.8 d (range, 30–60 d. The success rate of stent deployment was 96.7% (95% CI: 91.6%–99.5% and complete response to esophageal stenting was in 93.9% (95% CI: 82.2%–99.6%. The incidence of rebleeding was 13.2% (95% CI: 1.8%–32.8% and the overall mortality was 34.5% (95% CI: 24.8%–44.8%. Most of patients (87.4% died from hepatic or multiple organ failure, and only 12.6% of patients died from uncontrolled bleeding. There was no stent-related complication reported and the incidence of stent migration was 21.6% (95% CI: 4.7%–46.1%. Conclusion. Esophageal stent may be considered in patients with variceal bleeding refractory to conventional therapy.

  20. Time-dependent 3D simulations of the hemodynamics in a stented coronary artery

    International Nuclear Information System (INIS)

    Faik, Isam; Mongrain, Rosaire; Leask, Richard L; Rodes-Cabau, Josep; Larose, Eric; Bertrand, Olivier

    2007-01-01

    Stenting is becoming the major interventional cardiology procedure worldwide. However restenosis remains a major limitation to the effectiveness of stents. Alterations to the local hemodynamics in the stented segment of the artery could be a potential factor in the development of in-stent restenosis. The characterization of wall shear stress and of blood flow patterns in a stented artery is therefore necessary for a good understanding of the role of hemodynamics in the development of in-stent restenosis. We have used a time-dependent 3D numerical model of a stented coronary artery to study the characteristics of the blood flow and the shear stress distribution. Our results show that the presence of the stent produces significant secondary flow that is limited to an annulus in the near wall region. Low shear stress zones were localized in the vicinity of the struts while the tips of the struts exhibited high values of shear stress. These results support the hypothesis that local hemodynamics may affect the development of in-stent restenosis and could influence the choice of stent geometries for future stent designs

  1. Clinical experience in coronary stenting with the Vivant Z Stent.

    Science.gov (United States)

    Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H

    2005-06-01

    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.

  2. Local delivery of sirolimus nanoparticles for the treatment of in-stent restenosis.

    Science.gov (United States)

    Zago, Alexandre C; Raudales, José C; Attizzani, Guilherme; Matte, Bruno S; Yamamoto, German I; Balvedi, Julise A; Nascimento, Ludmila; Kosachenco, Beatriz G; Centeno, Paulo R; Zago, Alcides J

    2013-02-01

    To test the local delivery of sirolimus nanoparticles following percutaneous transluminal coronary angioplasty (PTCA) to treat in-stent restenosis (ISR) in a swine model. Coronary bare-metal stent (BMS) implantation reduces major adverse cardiac events when compared with PTCA; however, ISR rates remain high. Eighteen swine underwent BMS deployment guided by intravascular ultrasound (IVUS). Of these, 16 developed ISR (1 stent/swine) and underwent angioplasty with a noncompliant balloon (PTCA-NC). The animals were then randomized into four groups for local infusion of sirolimus nanoparticles through a porous balloon catheter, as follows: (1) PTCA-NC alone (control); (2) PTCA-NC + (polylactic acid)-based nanoparticle formulation (anionic 1); (3) PTCA-NC + (polylactic-co-glycolic acid)-based nanoparticle formulation (anionic 2); and (4) PTCA-NC + Eudragit RS nanoparticle formulation (cationic). Coronary angiography and IVUS follow-up were performed 28 days after ISR treatment. There was one episode of acute coronary occlusion with the cationic formulation. Late area loss was similar in all groups at 28 days according to IVUS. However, luminal volume loss (control = 20.7%, anionic 1 = 4.0%, anionic 2 = 6.7%, cationic = 9.6%; P = 0.01) and neointimal volume gain (control = 68.7%, anionic 1 = 17.4%, anionic 2 = 29.5%, cationic = 31.2%; P = 0.019) were significantly reduced in all treatment groups, especially in anionic 1. PTCA-NC followed by local infusion of sirolimus nanoparticles was safe and efficacious to reduce neointima in this model, and this strategy may be a promising treatment for BMS ISR. Further studies are required to validate this method in humans. Copyright © 2012 Wiley Periodicals, Inc.

  3. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    International Nuclear Information System (INIS)

    Moscarella, Elisabetta; Varricchio, Attilio; Stabile, Eugenio; Franzone, Anna; Granata, Francesco; Rapacciuolo, Antonio; Galasso, Gennaro; Capozzolo, Claudia; Cirillo, Plinio

    2015-01-01

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  4. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    Energy Technology Data Exchange (ETDEWEB)

    Moscarella, Elisabetta [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Varricchio, Attilio [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Stabile, Eugenio, E-mail: geko50@hotmail.com [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Franzone, Anna [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Granata, Francesco [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Rapacciuolo, Antonio; Galasso, Gennaro [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Capozzolo, Claudia [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Cirillo, Plinio [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); and others

    2015-10-15

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  5. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    Science.gov (United States)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare

  6. External pancreatic duct stent reduces pancreatic fistula: a meta-analysis and systematic review.

    Science.gov (United States)

    Patel, Krishen; Teta, Anthony; Sukharamwala, Prashant; Thoens, Jonathan; Szuchmacher, Mauricio; DeVito, Peter

    2014-01-01

    Postoperative pancreatic fistula formation (POPF) remains one of the most common and detrimental complications following pancreaticojejunostomy (PJ). The aim of this meta-analysis is to analyze the efficacy of external pancreatic duct stent placement in preventing POPF formation following PJ. The primary end-point was the incidence of POPF formation following pancreaticoduodenectomy (PD) in the presence and absence of external stent placement. Secondary outcomes examined were the incidence of perioperative mortality, delayed gastric emptying, postoperative wound infection, operative time, blood loss, and length of hospital stay. Four trials were included comprising 416 patients. External pancreatic duct stenting was found to reduce the incidence of both any grade POPF formation (OR 0.37, 95% CI = 0.23 to 0.58, p = 0.0001) and clinically significant (grade B or C) POPF formation (OR 0.50, 95% CI = 0.30 to 0.84, p = 0.0009) following PD. The use of an external stent was also found to significantly lessen length of hospital stay (SMD -0.39, 95% CI = -0.63 to -0.15, p = 0.001). This analysis has shown that external pancreatic duct stenting is indeed efficacious in the incidence of both any grade as well as clinically significant POPF formation following PD. Length of hospital stay was also found to be significantly less by external duct stenting. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Overview of evidence on emergency carotid stenting in patients with acute ischemic stroke due to tandem occlusions: a systematic review and meta-analysis.

    Science.gov (United States)

    Coelho, Andreia; Lobo, Miguel; Gouveia, Ricardo; Silveira, Diogo; Campos, Jacinta; Augusto, Rita; Coelho, Nuno; Canedo, Alexandra

    2018-01-23

    Endovascular intracranial thrombectomy (IT) has established itself as the standard of care in treating large-vessel anterior circulation acute ischemic stroke (AIS). However, internal carotid artery (ICA) stenosis/occlusion hampers distal access and controversy about simultaneous emergency ICA stenting ensues. The purpose of this review was to evaluate the safety of emergency ICA stenting in combination with IT for AIS with tandem occlusions. To our knowledge this is the first meta-analysis to evaluate emergency ICA stenting in tandem occlusions, combining results from studies with a control group. A systematic review and meta-analysis was conducted according to the recommendations of the Preferred Reporting Items for Systematic reviews and Meta- Analyses (PRISMA) statement. A total of 649 potentially relevant articles were initially selected. After reviewing at title or abstract level, 87 articles were read in full and 23 were included. These studies recruited 1000 patients, 220 submitted to IT with no emergency ICA stenting and 780 to IT and emergency ICA stenting. Successful revascularization (Thrombolysis in cerebral infarction scale - TICI≥2b) was achieved in 48.6-100%. Good outcome (modified Rankin scale - mRS≤2) ranged from 18.2-100%. Symptomatic intracranial haemorrhage (sICH) ranged from 0-45.7% (overall n=168; 17.2%). Mortality at 90 days ranged from 0-45.4% (overall n=114; 11.7%). Time to recanalization was significantly longer in the stenting group with an overall mean difference of 1.76 (95% Confidence Interval: 1.59-1.93). In this meta-analysis time to recanalization was significantly longer in the emergency ICA stenting group. There was no benefit from emergency stenting in parameters such as successful revascularization (TICI≥2b), clinical outcome (mRS≤2) or 90-day mortality. Data on sICH were scarce. Emergency ICA stenting appears to increase time to revascularization and increase the risk of complications with no demonstrated clinical

  8. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  9. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  10. [Value of the optical coherence tomography in the treatment guided of the stent failure. Case report].

    Science.gov (United States)

    Macías, Enrico; Tellez, Alejandro; Ochoa, Jorge; Ortíz, José E

    2014-01-01

    Since the advent of bare metal and drug-eluting stents, the surgical revascularization have declined considerably, however the thrombosis and in-stent restenosis are important complications of these devices. There are several factors that predispose to thrombosis and in-stent restenosis. Conventional angiography has serious limitations to determine the causes of stent failure. Optical coherence tomography is a very sensitive technique to determine the cause of thrombosis and in-stent restenosis. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  11. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    Science.gov (United States)

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by

  12. Efficacy of beta radiation in prevention of post-angioplasty restenosis : An interim report from the beta energy restenosis trial

    NARCIS (Netherlands)

    D. Meerkin; R. Bonan (Raoul); I.R. Crocker; A. Arsenault (André); P. Chougule; V.L.M.A. Coen (Veronique); D.O. Williams (David); P.W.J.C. Serruys (Patrick); S.B. King 3rd (Spencer)

    1998-01-01

    textabstractRestenosis remains a major limitation of coronary angioplasty in spite of major advances in techniques and technology. Recent studies have demonstrated that ionizing radiation may limit the degree of this problem. Gamma radiation has been shown to be effective in reducing in stent

  13. Successful Expansion of an Underexpanded Stent by Rotational Atherectomy

    Science.gov (United States)

    Vales, Lori; Coppola, John; Kwan, Tak

    2013-01-01

    The current routine use of intracoronary stents in percutaneous coronary intervention (PCI) has significantly reduced rates of restenosis, compared with balloon angioplasty alone. On the contrary, small post-stenting luminal dimensions due to undilatable, heavily calcified plaques have repeatedly been shown to significantly increase the rates of in-stent restenosis. Rotational atherectomy of lesions is an alternative method to facilitate PCI and prevent underexpansion of stents, when balloon angioplasty fails to successfully dilate a lesion. Stentablation, using rotational atherectomy to expand underexpanded stents deployed in heavily calcified plaques, has also been reported. We report a case via the transradial approach of rotational-atherectomy–facilitated PCI of in-stent restenosis of a severely underexpanded stent due to a heavily calcified plaque. We review the literature and suggest rotational atherectomy may have a role in treating a refractory, severely underexpanded stent caused by a heavily calcified plaque through various proposed mechanisms. PMID:24436587

  14. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  15. Systematic Review of Infrapopliteal Drug-Eluting Stents: A Meta-Analysis of Randomized Controlled Trials

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [NHS Foundation Trust, King' s Health Partners, Department of Interventional Radiology, Guy' s and St. Thomas' Hospitals (United Kingdom); Spiliopoulos, Stavros [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece); Diamantopoulos, Athanasios [NHS Foundation Trust, King' s Health Partners, Department of Interventional Radiology, Guy' s and St. Thomas' Hospitals (United Kingdom); Karnabatidis, Dimitris [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece); Sabharwal, Tarun [NHS Foundation Trust, King' s Health Partners, Department of Interventional Radiology, Guy' s and St. Thomas' Hospitals (United Kingdom); Siablis, Dimitris [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece)

    2013-06-15

    IntroductionDrug-eluting stents (DES) have been proposed for the treatment of infrapopliteal arterial disease. We performed a systematic review to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing infrapopliteal DES.Materials and MethodsPubMed (Medline), EMBASE (Excerpta Medical Database), AMED (Allied and Complementary medicine Database), Scopus, CENTRAL (Cochrane Central Register of Controlled Trials), online content, and abstract meetings were searched in September 2012 for eligible RCTs according to the preferred reporting items for systematic reviews and meta-analyses selection process. Risk of bias was assessed using the Cochrane Collaboration's tool. Primary endpoint was primary patency defined as absence of {>=}50 % vessel restenosis at 1 year. Secondary outcome measures included patient survival, limb amputations, change of Rutherford-Becker class, target lesion revascularization (TLR) events, complete wound healing, and event-free survival at 1 year. Risk ratio (RRs) were calculated using the Mantel-Haenszel fixed effects model, and number-needed-to-treat values are reported.ResultsThree RCTs involving 501 patients with focal infrapopliteal lesions were analyzed (YUKON-BTX, DESTINY, and ACHILLES trials). All three RCTs included relatively short and focal infrapopliteal lesions. At 1 year, there was clear superiority of infrapopliteal DES compared with control treatments in terms of significantly higher primary patency (80.0 vs. 58.5 %; pooled RR = 1.37, 95 % confidence interval [CI] = 1.18-1.58, p < 0.0001; number-needed-to-treat (NNT) value = 4.8), improvement of Rutherford-Becker class (79.0 vs. 69.6 %; pooled RR = 1.13, 95 % CI = 1.002-1.275, p = 0.045; NNT = 11.1), decreased TLR events (9.9 vs. 22.0 %; pooled RR = 0.45, 95 % CI = 0.28-0.73, p = 0.001; NNT = 8.3), improved wound healing (76.8 vs. 59.7 %; pooled RR = 1.29, 95 % CI = 1.02-1.62, p = 0.04; NNT = 5.9), and better overall

  16. Systematic Review of Infrapopliteal Drug-Eluting Stents: A Meta-Analysis of Randomized Controlled Trials

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Spiliopoulos, Stavros; Diamantopoulos, Athanasios; Karnabatidis, Dimitris; Sabharwal, Tarun; Siablis, Dimitris

    2013-01-01

    IntroductionDrug-eluting stents (DES) have been proposed for the treatment of infrapopliteal arterial disease. We performed a systematic review to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing infrapopliteal DES.Materials and MethodsPubMed (Medline), EMBASE (Excerpta Medical Database), AMED (Allied and Complementary medicine Database), Scopus, CENTRAL (Cochrane Central Register of Controlled Trials), online content, and abstract meetings were searched in September 2012 for eligible RCTs according to the preferred reporting items for systematic reviews and meta-analyses selection process. Risk of bias was assessed using the Cochrane Collaboration’s tool. Primary endpoint was primary patency defined as absence of ≥50 % vessel restenosis at 1 year. Secondary outcome measures included patient survival, limb amputations, change of Rutherford–Becker class, target lesion revascularization (TLR) events, complete wound healing, and event-free survival at 1 year. Risk ratio (RRs) were calculated using the Mantel–Haenszel fixed effects model, and number-needed-to-treat values are reported.ResultsThree RCTs involving 501 patients with focal infrapopliteal lesions were analyzed (YUKON-BTX, DESTINY, and ACHILLES trials). All three RCTs included relatively short and focal infrapopliteal lesions. At 1 year, there was clear superiority of infrapopliteal DES compared with control treatments in terms of significantly higher primary patency (80.0 vs. 58.5 %; pooled RR = 1.37, 95 % confidence interval [CI] = 1.18–1.58, p < 0.0001; number-needed-to-treat (NNT) value = 4.8), improvement of Rutherford–Becker class (79.0 vs. 69.6 %; pooled RR = 1.13, 95 % CI = 1.002–1.275, p = 0.045; NNT = 11.1), decreased TLR events (9.9 vs. 22.0 %; pooled RR = 0.45, 95 % CI = 0.28–0.73, p = 0.001; NNT = 8.3), improved wound healing (76.8 vs. 59.7 %; pooled RR = 1.29, 95 % CI = 1.02–1.62, p = 0.04; NNT = 5.9), and better

  17. Influence of covered stent versus bare stent on long-term efficacy of transjugular intrahepatic portosystemic shunt: a meta-analysis

    Directory of Open Access Journals (Sweden)

    XU Lu

    2016-10-01

    Full Text Available Objective To investigate the long-term postoperative efficacy of transjugular intrahepatic portosystemic shunt (TIPS using polytetrafluoroethylene (PTFE-covered stent or bare stent, and to provide a basis of evidence-based medicine for the selection of stent in TIPS. Methods CBM, Wanfang Data, CNKI, VIP, MEDLINE, and PubMed were searched for controlled trials on TIPS in the treatment of cirrhotic portal hypertension published form 1989 to 2015; the studies which met the inclusion criteria were selected, and quality assessment was performed for these articles. RevMan 5.3 software was used to analyze the incidence rates of stent dysfunction and hepatic encephalopathy and 1-year survival rate after TIPS, and funnel plots were used to analyze publication bias. Results A total of 11 studies were included, consisting of 698 patients in PTFE-covered stent group and 1283 patients in bare stent group. The results of the meta-analysis showed that the PTFE-covered stent group showed a significantly lower incidence rate of stent dysfunction than the bare stent group (14.8% vs 47.0%, OR=0.18, 95% CI: 0.13-0.24, P<0.001. There was no significant difference in the incidence rate of hepatic encephalopathy between the two groups (23.5% vs 25.7%, OR=0.88, 95% CI: 0.66-1.17, P=0.37. The PTFE-covered stent group had a significantly higher 1-year survival rate than the bare stent group (76.9% vs 62.7%, OR=2.10, 95% CI: 1.54-2.85, P<0.001. The funnel plots which were plotted based on the incidence rates of stent dysfunction and hepatic encephalopathy and 1-year survival rate lacked symmetry, which suggested that a certain degree of publication bias might exist. Conclusion Compared with the bare stent, the PTFE-covered stent can improve stent dysfunction and 1-year survival rate after TIPS, while there is no significant change in the incidence rate of hepatic encephalopathy. Therefore, the PTFE-covered stent has certain advantages over the bare stent in TIPS. In

  18. Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) trial

    NARCIS (Netherlands)

    D.R. Holmes Jr (David); J.R. Granett (Jeffrey); J.J. Popma (Jeffrey); P.J. Fitzgerald (Peter); D. Fischman (David); J.J. Ferguson (James); A.M. Lincoff (Michael); S. Goldberg (Sheldon); J.A. Brinker; R. Chan; B.R. Davis (Barry); M. Poland; A.M. Zeiher (Andreas); J.T. Willerson (James); S.B. King 3rd (Spencer); L.M. Shapiro; M. Savage (Michael); J.M. Lablanche (Jean Marc); J.E. Tcheng (James); L. Grip (Lars); P.W.J.C. Serruys (Patrick)

    2002-01-01

    textabstractBACKGROUND: Restenosis after percutaneous coronary intervention (PCI) is a major problem affecting 15% to 30% of patients after stent placement. No oral agent has shown a beneficial effect on restenosis or on associated major adverse cardiovascular events. In limited trials, the oral

  19. Therapeutic evaluation of retrievable esophageal covered stent in treating achalasia

    International Nuclear Information System (INIS)

    Li Yuwei; Zhang Fuqiang; Yuan Liang; Li Yunhui; Luo Bin; Yu Li; Sun Dingqiang

    2010-01-01

    Objective: To evaluate the clinical effect of retrievable esophageal covered metal internal stent in treating patients with achalasia. Methods: Under DSA guidance, peroral 'Z-type' double horn covered metal internal stent implantation was performed in 16 patients with achalasia. Esophagography was carried out about 28 days after the procedure and the stent was retrieved. Results: Of 16 cases, the stent fell off into the stomach two weeks after the operation in one. And the stent was successfully replaced after it was taken out. The placed stent was successfully retrieved in all cases 28 days after the treatment. No serious complications occurred. All the patients were followed up for 3 months to 3 years. During the follow-up period restenosis of the esophagus developed in two cases (at one and 1.5 years respectively), and the restenosis degree was relived after balloon dilation. Clinically, no esophageal symptoms, such as dysphagia, occurred in all patients. Conclusion: As a simple and safe technique, the retrievable esophageal covered metal internal stent implantation is very effective with fewer complications for the treatment of achalasia. Moreover, the technique carries lower restenosis occurrence. (authors)

  20. Angiographic follow-up after carotid artery stenting of bifurcation stenosis; Angiographische Verlaufskontrolle nach Stentimplantation zur Behandlung der Karotisbifurkationsstenose

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)

    2006-08-15

    Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)

  1. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  2. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    Science.gov (United States)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; Pstents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  3. High coronary calcium score and post-procedural CK-MB are noninvasive predictors of coronary stent restenosis

    Directory of Open Access Journals (Sweden)

    Lee JB

    2017-02-01

    Full Text Available Jae-Beom Lee,1 Yun-Seok Choi,2 Woo-Baek Chung,2 Ami Kwon,2 Chul-Soo Park,2 Man-Young Lee2 1Anyang Sam Hospital, 2Division of Cardiology, Department of Internal Medicine, Youido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea Purpose: High coronary calcium score (CCS and post-procedural cardiac enzyme may be related with poor outcomes in patients with coronary stent implantation. Methods: A total of 1,072 patients (63.2% male, mean age: 61.7±10.3 years who underwent coronary multi-detect computed tomography at index procedure and follow-up coronary angiography (CAG after drug-eluting stent (DES were divided into two groups: those with and without target lesion revascularization (TLR; >50% reduction in luminal stent diameter or angina symptoms on follow-up CAG. The CCSs for predicting stent revascularization were elucidated. Results: There were no significant differences between the two groups with regard to risk factors. The initial CCS was significantly higher in the TLR group (1,102.4±743.7 vs 345.8±51.05, P=0.04. After adjustment of significant factors for TLR, only CCS and post-procedural creatine kinase MB form (CK-MB elevation were significant predictors of coronary artery TLR. Receiver operation curve revealed that >800 in CCS had 69% in sensitivity and 88% in specificity about predicting the TLR. Conclusion: High CCS with post-procedural CK-MB might be the useful predictors for TLR after DES implantation. Keywords: coronary restenosis, drug-eluting stents, calcium, creatine kinase

  4. Percutaneous coronary intervention with second-generation drug-eluting stent versus bare-metal stent: Systematic review and cost-benefit analysis.

    Science.gov (United States)

    Poder, Thomas G; Erraji, Jihane; Coulibaly, Lucien P; Koffi, Kouamé

    2017-01-01

    Drug-eluting stents (DESs) were considered as ground-breaking technology promising to eradicate restenosis and the necessity to perform multiple revascularization procedures subsequent to percutaneous coronary intervention. Soon after DESs were released on the market, however, there were reports of a potential increase in mortality and of early or late thrombosis. In addition, DESs are far more expensive than bare-metal stents (BMSs), which has led to their limited use in many countries. The technology has improved over the last few years with the second generation of DESs (DES-2). Moreover, costs have come down and an improved safety profile with decreased thrombosis has been reported. Perform a cost-benefit analysis of DES-2s versus BMSs in the context of a publicly funded university hospital in Quebec, Canada. A systematic review of meta-analyses was conducted between 2012 and 2016 to extract data on clinical effectiveness. The clinical outcome of interest for the cost-benefit analysis was target-vessel revascularization (TVR). Cost units are those used in the Quebec health-care system. The cost-benefit analysis was based on a 2-year perspective. Deterministic and stochastic models (discrete-event simulation) were used, and various risk factors of reintervention were considered. DES-2s are much more effective than BMSs with respect to TVR rate ratio (i.e., 0.29 to 0.62 in more recent meta-analyses). DES-2s seem to cause fewer deaths and in-stent thrombosis than BMSs, but results are rarely significant, with the exception of the cobalt-chromium everolimus DES. The rate ratio of myocardial infraction is systematically in favor of DES-2s and very often significant. Despite the higher cost of DES-2s, fewer reinterventions can lead to huge savings (i.e., -$479 to -$769 per patient). Moreover, the higher a patient's risk of reintervention, the higher the savings associated with the use of DES-2s. Despite the higher purchase cost of DES-2s compared to BMSs

  5. StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

    OpenAIRE

    Cura, Fernando; Albertal, Mariano; Candiello, Alfonsina; Nau, Gerardo; Bonvini, Victor; Tricherri, Hernan; Padilla, Lucio T.; Belardi, Jorge A.

    2013-01-01

    Introduction Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. Methods From December 2010 to December 2011, 38 patients (54 stents) were analyzed using IVUS and StentBoost. Minimal stent diameter and...

  6. Drug-Eluting Balloon versus New-Generation Drug-Eluting Stent for the Treatment of In-Stent Restenosis: An Updated Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Kong-Yong Cui

    2018-01-01

    Conclusions: The current meta-analysis showed that DEB and new-generation DES had comparable safety and efficacy for the treatment of ISR in RCTs. However, treatment with DEB was associated with higher risk of all-cause mortality in the real-world nonrandomized studies.

  7. Stent thrombosis and restenosis: what have we learned and where are we going? The Andreas Grüntzig Lecture ESC 2014

    Science.gov (United States)

    Byrne, Robert A.; Joner, Michael; Kastrati, Adnan

    2015-01-01

    Modern-day stenting procedures leverage advances in pharmacotherapy and device innovation. Patients treated with contemporary antiplatelet agents, peri-procedural antithrombin therapy and new-generation drug-eluting stents (DES) have excellent outcomes over the short to medium term. Indeed, coupled with the reducing costs of these devices in most countries there remain very few indications where patients should be denied treatment with standard-of-care DES therapy. The two major causes of stent failure are stent thrombosis (ST) and in-stent restenosis (ISR). The incidence of both has reduced considerably in recent years. Current clinical registries and randomized trials with broad inclusion criteria show rates of ST at or stent failure neoatherosclerotic change within the stented segment represents a final common pathway for both thrombotic and restenotic events. In future, a better understanding of the pathogenesis of this process may translate into improved late outcomes. Moreover, the predominance of non-stent-related disease as a cause of subsequent myocardial infarction during follow-up highlights the importance of lifestyle and pharmacological interventions targeted at modification of the underlying disease process. Finally, although recent developments focus on strategies which circumvent the need for chronically indwelling stents—such as drug-coated balloons or fully bioresorbable stents—more data are needed before the wider use of these therapies can be advocated. PMID:26417060

  8. Prosthetic bypass for restenosis after endarterectomy or stenting of the carotid artery.

    Science.gov (United States)

    Illuminati, Giulio; Belmonte, Romain; Schneider, Fabrice; Pizzardi, Giulia; Calió, Francesco G; Ricco, Jean-Baptiste

    2017-06-01

    The objective of this study was to evaluate the results of prosthetic carotid bypass (PCB) with polytetrafluoroethylene (PTFE) grafts as an alternative to carotid endarterectomy (CEA) in treatment of restenosis after CEA or carotid artery stenting (CAS). From January 2000 to December 2014, 66 patients (57 men and 9 women; mean age, 71 years) presenting with recurrent carotid artery stenosis ≥70% (North American Symptomatic Carotid Endarterectomy Trial [NASCET] criteria) were enrolled in a prospective study in three centers. The study was approved by an Institutional Review Board. Informed consent was obtained from all patients. During the same period, a total of 4321 CEAs were completed in the three centers. In these 66 patients, the primary treatment of the initial carotid artery stenosis was CEA in 57 patients (86%) and CAS in nine patients (14%). The median delay between primary and redo revascularization was 32 months. Carotid restenosis was symptomatic in 38 patients (58%) with transient ischemic attack (n = 20) or stroke (n = 18). In this series, all patients received statins; 28 patients (42%) received dual antiplatelet therapy, and 38 patients (58%) received single antiplatelet therapy. All PCBs were performed under general anesthesia. No shunt was used in this series. Nasal intubation to improve distal control of the internal carotid artery was performed in 33 patients (50%), including those with intrastent restenosis. A PTFE graft of 6 or 7 mm in diameter was used in 6 and 60 patients, respectively. Distal anastomosis was end to end in 22 patients and end to side with a clip distal to the atherosclerotic lesions in 44 patients. Completion angiography was performed in all cases. The patients were discharged under statin and antiplatelet treatment. After discharge, all of the patients underwent clinical and Doppler ultrasound follow-up every 6 months. Median length of follow-up was 5 years. No patient died, sustained a stroke, or presented with a

  9. Brachytherapy for coronary restenosis: state of art in 2003

    International Nuclear Information System (INIS)

    Latorzeff, I.; Delannes, M.; Latorzeff, I.; Carrie, D.; Alibelli, M.J.; Bonnet, J.; Duthil, P.

    2003-01-01

    Based on therapeutic approach for benign diseases, vascular brachytherapy decreases smooth vascular muscle cells proliferation and multiplication which lead to the formation of the neo-intima. The radioactive positive action affects arterial recoil due to post angioplasty vessel injury. Randomized studies has shown good angiographic results up to 6 months of follow-up, with 50% in-stent restenosis rate decrease and on the analysed segment as well. Decrease on Mace and TLR show statistically significance. Results don't correlate with emitter and beta emitters had been introduced in France recently. Vascular brachytherapy is actually indicated for in-stent restenosis, there is no evidence to perform this treatment for de novo lesion. Geographic miss, source centering, late thrombosis and pullback procedure may interfere with treatment quality. IVUS allows best target volume determination to a higher quality level. Internationals guidelines such as Eva-Gec-Estro recommendations could increase treatment safety and enable development of an optimal technique. (authors)

  10. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    Science.gov (United States)

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  11. Recruitable collateral blood flow index predicts coronary instent restenosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Lassen, Jens Flensted

    2007-01-01

    AIMS: Collateral flow may influence long-term results after percutaneous coronary intervention (PCI) because of haemodynamic forces compete with the antegrade flow through the dilated lesion. The aim of the study was to assess the influence of recruitable collateral blood flow on restenosis...... in patients undergoing PCI with bare metal stents and using optimal antithrombotic treatment. METHODS AND RESULTS: In 95 patients, 95 de novo lesions were treated with PCI and a bare metal stent. Fractional flow reserve (FFR) at maximum hyperaemia induced by intravenous adenosine was determined. The pressure.......02-1.12, P = 0.016). CONCLUSION: Recruitable collateral blood flow measured during balloon inflation predicts angiographic instent restenosis in PCI patients treated with bare metal stents. Udgivelsesdato: 2007-Aug...

  12. Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits.

    Directory of Open Access Journals (Sweden)

    Matthijs S Ruiter

    Full Text Available The introduction of drug-eluting stents (DES has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC, endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface.Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions.Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation.We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient.

  13. Experimental study on effect of dexamethasone to the in-stent restenosis after vascular intervention

    International Nuclear Information System (INIS)

    Wang Jianbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Jiaping; Zhang Longjuan

    2007-01-01

    Objective: To evaluate the effect of dexamethasone to the cultured rat thoracic aortic smooth muscle cells (SMC) in vitro, and explore the role on it's prevention and cure for the in-stent restenosis after vascular intervention. Methods: The rat thoracic aortic SMC were harvested and cultured for six to ten passages. The cultured SMC were synchronized and then restimutated to enter the cell cycle, and treated with incremental concentrations of dexamethasone or without dexamethasone as control. The proliferative assay was performed with MTT method in the different time points after treatment. RT-PCR was performed to assay the level of proliferating cell nuclear antigen (PCNA) mRNA. Results: 1. Dexamethasone progressively inhibited rat aortic SMC proliferation in a concentration-dependent fashion. The A value was statistically significant for different concentrations (F=36.02, P -6 and 10 -5 mol/L (P=0.065) or between 10 -11 mol/L and control group (P 0.567). 2. RT-PCR suggested dexamethasone significantly decreased rat aortic SMC PCNA mRNA transcription in a concentration-dependent fashion. Statistical analysis indicated F=15.407 and P -9 or 10 -11 mol/L groups by post hoc analysis. Conclusions: Dexamethasone inhibits rat aortic SMC proliferation in a concentration- dependent fashion. The data suggest that effective action concentration is 10 -7 mol/L with persistent time up to 96 hours or more. Dexamethasone may play the inhibit role to SMC at lower concentration with prolonging action time. (authors)

  14. Computational hemodynamics of an implanted coronary stent based on three-dimensional cine angiography reconstruction.

    Science.gov (United States)

    Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C

    2005-01-01

    Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.

  15. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  16. Influence of 103Pd radioactive stent on apoptosis of vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Liu Yingmei; Wu Wei; Chen Xiaochao; Zhang Xuming; Wang Jingfeng; Wei Yulin; Yang Li

    2003-01-01

    Objective: To evaluate the influence of 103 Pd radioactive stent on apoptosis and its relative genes bcl-2 and bax in injured vascular media smooth muscle cells of rabbit abdominal arteries and to investigate the mechanism of 103 Pd radioactive stent for preventing restenosis after angioplasty. Methods: Fifty male New Zealand rabbits were randomized into stent group and 103 Pd stent group. Each group was subdivided into 5 sub-groups. Control group was set up. The study arteries were harvested at 3, 7, 14, 28 and 56 d after stenting and the pathomorphology, apoptosis analysis and in situ hybridization were performed to evaluate the expression of bcl-2 and bax mRNA. Results: The severity of the restenosis in 103 Pd stent group was less than that of stent group. It was most obvious at the 56th day (P 103 Pd stent group had much more apoptosis of vascular smooth muscle cells than stent group did and reached the peak at the 7th day, (14.72±0.53)% vs (12.42±1.13)% (P 103 Pd stent group was much lower than that of stent group at 3 to 28 d. The difference was most obvious at the 28th day after stenting, (18.43± 0.67)% vs (21.55±0.93)% (P 103 Pd stent group was higher than that of stent group, the peak was at the 7th day, (11.17±0.94)% vs (9.30±1.01)%. The ratio of bcl-2/bax in 103 Pd stent group was much lower than that of stent group at 3 to 28 d. Linear correlation analysis showed that there was significant negative correlation between bcl-2 mRNA and apoptosis. Between bax mRNA and apoptosis, the positive correlation was found (P 103 Pd radioactive stent induced more significant apoptosis in vascular media smooth muscle cells by promoting the expression of apoptosis related genes and relieved the expanding of restenosis

  17. XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent

    NARCIS (Netherlands)

    Beijk, Marcel A. M.; Piek, Jon J.

    2007-01-01

    Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the

  18. Subintimal Recanalization of Occluded Stents: The Substent Technique

    International Nuclear Information System (INIS)

    Diamantopoulos, Athanasios; Katsanos, Konstantinos; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan–Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 ± 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 ± 90.78 mm. The mean occluded stented segment length was 90.21 ± 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year’s follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few

  19. The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry.

    Science.gov (United States)

    Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M

    2012-01-01

    This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Endovascular brachytherapy to prevent restenosis after angioplasty; Endovaskulaere Brachytherapie in der Restenoseprophylaxe nach Angioplastie und Stentimplantation: Eine Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, W.A.; Bohndorf, K. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie

    2003-02-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [German] Die endovaskulaere Radiotherapie stellt das erste erfolgreiche Therapiekonzept in der Restenoseprophylaxe nach PTA und Stentimplantation dar. Am 3.11.2000 hat die amerikanische Food and Drug Administration erstmalig zwei Brachytherapiegeraete zur Restenoseprophylaxe nach Koronararterien-Stenting zugelassen. Grosse multizentrische, kontrollierte Studien wurden fuer das koronare Stromgebiet mit positiven Ergebnissen publiziert, die Datenlage im peripheren Stromgebiet ist noch ungenuegend. Beta-Strahler bieten Vorteile in der Anwendung, moeglicherweise auch in der Sicherheit, Gamma-Strahler dagegen sind besser klinisch evaluiert. Die primaere Indikation zur endovaskulaeren Brachytherapie

  1. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  2. Biodegradable magnesium-alloy stent:current situation in research

    International Nuclear Information System (INIS)

    Chen Hua; Zhao Xianxian

    2011-01-01

    In recent years, permanent metal stents are employed in the majority of interventional therapies; nevertheless, such kind of stents carries the problems of thrombosis and restenosis. Therefore, the biodegradable magnesium alloy stent has become the focus of attention. Theoretically, it has overcome the problems caused by permanent metal stents, so it is the development direction to use the biodegradable magnesium alloy in future. The authors believe that biodegradable magnesium alloy stents will be widely used in interventional procedures for many diseases. (authors)

  3. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  4. Biomimicry, vascular restenosis and coronary stents.

    Science.gov (United States)

    Schwartz, R S; van der Giessen, W J; Holmes, D R

    1998-01-01

    Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.

  5. Use of drug-eluting stents in Victorian public hospitals.

    Science.gov (United States)

    Yan, Bryan P; Ajani, Andrew E; Duffy, Stephen J; New, Gishel; Horrigan, Mark; Szto, Gregory; Walton, Antony; Eccleston, David; Lefkovits, Jeffery; Black, Alexander; Sebastian, Martin; Brennan, Angela L; Reid, Christopher M; Clark, David J

    2006-10-02

    We aimed to assess the pattern of use of drug-eluting stents (DESs) in patients undergoing percutaneous coronary interventions (PCIs) in Victorian public hospitals. Prospective study comparing the use of one or more DESs versus bare-metal stents (BMSs) only, in consecutive patients undergoing 2428 PCIs with stent implantation from 1 April 2004 to 31 December 2005 at seven Victorian public hospitals. Adherence to current Victorian Department of Human Services guidelines which recommend DES use in patients with high-risk features for restenosis (diabetes, small vessels, long lesions, in-stent restenotic lesions, chronic total occlusions and bifurcation lesions). Of the 2428 PCIs performed, at least one DES was implanted in 1101 (45.3%) and BMSs only were implanted in 1327 (54.7%). In 87.7% (966/1101) of PCI with DESs, there was at least one criterion for high risk of restenosis. DESs were more likely to be used in patients with diabetes (risk ratio [RR], 2.45; 95% CI, 2.02-2.97), small vessels (RR, 3.35; 95%CI, 2.35-4.76), long lesions (RR, 3.87; 95% CI, 3.23-4.65), in-stent restenotic lesions (RR, 3.98; 95%CI, 2.67-6.06), chronic total occlusions (RR, 1.30; 95% CI, 0.51-2.88) and bifurcation lesions (RR, 2.23; 95%CI, 1.57-3.17). However, 66.2% (1608/2428) of all PCIs were in patients eligible for DESs according to Victorian guidelines, and in 39.9% (642/1608) of these PCIs, a BMS was used. In Victorian public hospitals, DESs have been largely reserved for patients at high risk of restenosis in accordance with Department of Human Services guidelines. However, many patients with high-risk criteria for restenosis did not receive DESs. Greater use of DESs in these patients may improve outcomes by reducing the need for repeat revascularisation.

  6. Undilatable Stent Neoatherosclerosis Treated with Ad Hoc Rotational Atherectomy

    Directory of Open Access Journals (Sweden)

    Michael Koutouzis

    2017-01-01

    Full Text Available A middle age woman with known ischemic heart disease and old stents in proximal left anterior descending coronary artery (LAD was admitted to Coronary Care Unit with acute coronary syndrome. The coronary angiography showed one vessel disease with significant restenosis within the previously implanted stents. The lesion was tough and remained undilatable despite high pressure balloon inflation. Eventually, the balloon ruptured creating a massive dissection of the LAD beginning immediately after the distal part of the undilatable lesion. We proceeded with a challenging ad hoc rotational atherectomy of the lesion and finally stenting of the lesion. In-stent restenosis many years after stent implantation is considered to be mainly due to neoatheromatosis compared to intimal hyperplasia, making lesion treatment more difficult and unpredictable.

  7. Renal artery stent fracture with refractory hypertension: a case report and review of the literature.

    Science.gov (United States)

    Chua, Su-Kiat; Hung, Huei-Fong

    2009-07-01

    A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.

  8. Left-main restenosis in the DES era-a call for action.

    Science.gov (United States)

    di Palma, Gaetano; Cortese, Bernardo

    2017-11-10

    Percutaneous treatment of the unprotected left main trunk (ULM), defined as a vessel without patent bypass graft either to the left circumflex (LCX) or left anterior descending (LAD) artery, has gained a precise role thanks to recent scientific evidence. Although new generation drug-eluting stents have already proven to be safer, there is still a consistent risk of restenosis and late adverse events. The optimal management of a ULM restenosis is still debated. Here we aim at presenting a review of the available data in literature and show our choice for treating it. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    Science.gov (United States)

    Winn, Bradley Huegh

    Cardiovascular disease is the leading cause of mortality in The United States and Europe, accounting for approximately half of all deaths. The most common form of cardiovascular disease is atherosclerosis, which is characterized by the formation of fatty atheromatous plaques that can grow to occlude the vessel lumen, thus causing ischemia distal to the occlusion. This is commonly treated using balloon angioplasty, which is usually done in conjunction with the deployment of a stent. Stent deployment helps hold the vessel open following the local injury caused by balloon inflation and prevents elastic recoil and subsequent negative remodeling. Stenting has been shown to significantly reduce restenosis rates from approximately 20-50% without a stent to about 10-30% with stent deployment. However, restenosis still remains the main cause of long-term stent failure. In basic terms, a balloon angioplasty procedure is a forceful displacement of an atherosclerotic lesion serving to widen the vessel lumen to increase blood flow. This procedure causes stretching of the vessel wall, tears in the atherosclerotic plaques, and general damage to the vessel in turn signaling a complex cascade of thrombosis, inflammation, intimal thickening, and vascular remodeling. Stent deployment also further complicates the immunological response by triggering a foreign body response from the implantation of a biomaterial into the body. When performing an angioplasty procedure, particularly in conjunction with stent deployment, a certain degree of vascular injury is inevitable. However, the initial injury can be further complicated by the body's local reaction to the implanted biomaterial, the severity of which can ultimately dictate the degree of restenosis and subsequently affect procedural success. The proliferative response of VSMCs to the various afore mentioned stimuli results in the formation of often copious amounts of neointimal tissue, generally known as intimal hyperplasia. The

  10. Differences in optical coherence tomographic findings and clinical outcomes between excimer laser and cutting balloon angioplasty for focal in-stent restenosis lesions.

    Science.gov (United States)

    Nishino, Masami; Lee, Yasuharu; Nakamura, Daisuke; Yoshimura, Takahiro; Taniike, Masayuki; Makino, Nobuhiko; Kato, Hiroyasu; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Yamada, Yoshio

    2012-10-01

    In-stent restenosis (ISR), especially focal ISR, after percutaneous coronary intervention (PCI) remains one of the major clinical problems in the drug-eluting stent (DES) era. Several reports have revealed that excimer laser coronary angioplasty (ELCA) is useful for ISR; however, detailed findings after ELCA are unknown. Therefore, we investigated the condition of the neointima after ELCA for ISR with optical coherence tomography (OCT) and compared the OCT findings and clinical outcome between ELCA and cutting-balloon angioplasty (CBA). Twenty-one consecutive patients with focal ISR who underwent ELCA or CBA were enrolled. All patients underwent 12- to 15-month follow-up coronary angiography. OCT was performed immediately after successful PCI to evaluate the neointimal condition in the ISR lesion. We compared the following OCT parameters between ELCA and CBA groups: maximal thickness of remaining in-stent neointima (MTN), number of tears, minimum lumen dimension (MLD), and minimum lumen area (MLA). We also evaluated clinical outcomes, including target vessel revascularization, acute myocardial infarction, death, and stent thrombosis. MLA in the ELCA group (n = 10) was significantly larger than in the CBA group, and number of tears in the ELCA group was significantly lower than in the CBA group. A trend was shown toward lower TLR with ELCA versus CBA (10.0% vs 45.5%). OCT immediately after ELCA for ISR lesions revealed larger lumen area and smaller number of tears compared with CBA, which may support favorable effects of ELCA for focal ISR.

  11. In vitro and in vivo cell-capture strategies using cardiac stent technology - A review.

    Science.gov (United States)

    Ravindranath, Rohan R; Romaschin, Alexander; Thompson, Michael

    2016-01-01

    Stenosis is a symptom of coronary artery disease (CAD), and is caused by narrowing of arteries in the heart. Over the last several decades, medical implants such as cardiac stents have been developed to counter stenosis. Upon implantation of a stent to open up a restricted artery, narrowing of the artery can reoccur (restenosis), due to an immune response launched by the body towards the stent. Currently, restenosis is a major health concern for patients who have undergone heart surgery for coronary artery disease. Recently, there have been new methods developed to combat restenosis, which have shown potential signs of success. One proposed method is the use of stents to capture cells, thereby reducing immune response. This review will explore the different methods for cell capture both in vitro and in vivo. Biological modifications of the stent will be surveyed, as well as the use of surface science to immobilize biological probes. Immobilization of proteins and nucleotides, as well as use of magnetic field are all methods that will be further discussed. Finally, concluding remarks and future prospects will be presented. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 ± 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 ± 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 ± 9.1 %, lesion binary restenosis rate was 64.1 ± 8.3 %, and repeat intervention-free survival was 93.6 ± 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications

  13. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  14. Two Blades-Up Runs Using the JetStream Navitus Atherectomy Device Achieve Optimal Tissue Debulking of Nonocclusive In-Stent Restenosis: Observations From a Porcine Stent/Balloon Injury Model.

    Science.gov (United States)

    Shammas, Nicolas W; Aasen, Nicole; Bailey, Lynn; Budrewicz, Jay; Farago, Trent; Jarvis, Gary

    2015-08-01

    To determine the number of runs with blades up (BU) using the JetStream Navitus to achieving optimal debulking in a porcine model of femoropopliteal artery in-stent restenosis (ISR). In this porcine model, 8 limbs were implanted with overlapping nitinol self-expanding stents. ISR was treated initially with 2 blades-down (BD) runs followed by 4 BU runs (BU1 to BU4). Quantitative vascular angiography (QVA) was performed at baseline, after 2 BD runs, and after each BU run. Plaque surface area and percent stenosis within the treated stented segment were measured. Intravascular ultrasound (IVUS) was used to measure minimum lumen area (MLA) and determine IVUS-derived plaque surface area. QVA showed that plaque surface area was significantly reduced between baseline (83.9%±14.8%) and 2 BD (67.7%±17.0%, p=0.005) and BU1 (55.4%±9.0%, p=0.005) runs, and between BU1 and BU2 runs (50.7%±9.7%, patherectomy. JetStream Navitus achieved optimal tissue debulking after 2 BD and 2 BU runs with no further statistical gain in debulking after the BU2 run. Operators treating ISR with JetStream Navitus may be advised to limit their debulking to 2 BD and 2 BU runs to achieve optimal debulking. © The Author(s) 2015.

  15. Drug-eluting stents for acute coronary syndrome: a meta-analysis of randomized controlled trials.

    Directory of Open Access Journals (Sweden)

    Lishan Wang

    Full Text Available Drug-eluting stents (DES are increasingly used for treatment of acute coronary syndrome (ACS. However, clinical efficacy and safety of various types of DES is not well established in these subjects. We therefore evaluated clinical utility of second-generation and first-generation DES in patients with ACS by conducting a meta-analysis.A search of Medline, Embase, the Cochrane databases, and Web of Science was made. Randomized controlled trials (RCTs which compared second-generation DES (everolimus-eluting stents [EES] or zotarolimus-eluting stents [ZES] versus first-generation DES (sirolimus-eluting stents [SES] or paclitaxe-eluting stents [PES] in patients with ACS and provided data on clinical efficacy or safety endpoints were included. Pooled estimates were calculated using random-effects model.A total of 2,757 participants with ACS in 6 RCTs were included. Compared with first-generation one, second-generation DES trended to be associated with the decreased incidence of definite or probable stent thrombosis in ACS patients (risk ratio [RR]  = 0.60, 95% confidence intervals [CI] 0.33 to 1.07, p = 0.09. However, the rate of target lesion revascularization (TLR significantly increased in second-generation DES (RR = 2.08, 95%CI 1.25 to 3.47, p = 0.005. There were no significant differences in the incidence of major adverse cardiac events (MACEs, all-cause death, cardiac death, and recurrent myocardial infarction between the two arms (all p>0.10. The second-generation EES showed a tendency towards lower risk of MACEs (p = 0.06 and a beneficial effect on reducing stent thrombosis episodes (p = 0.009, while the second-generation ZES presented an increased occurrence of MACEs (p = 0.02 and TLR (p = 0.003.Second-generation DES, especially EES, appeared to present a lower risk of stent thrombosis, whereas second-generation ZES might increase the need for repeat revascularization in ACS patients. During coronary

  16. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  17. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  18. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention

    OpenAIRE

    Baschet, Louise; Bourguignon, Sandrine; Marque, S?bastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    Objective To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. Methods A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117?762 patient-years with 76 randomised trials. The main effectiveness criterion was major c...

  19. Superficial femoral artery TASC D Registry: twelve-month effectiveness analysis of the Pulsar-18 SE nitinol stent in patients with critical limb ischemia.

    Science.gov (United States)

    Lichtenberg, M; Stahlhoff, W; Boese, D

    2013-08-01

    Single center observational study analyzing the primary patency rate and freedom from target lesions revascularization rate of the Pulsar-18 nitinol stent after recanalization of long superficial femoral artery (SFA) occlusions (TASC D) in 22 patients with critical limb ischemia (CLI). Between 1/2011 and 7/2011, 22 consecutive patients (9 male, 13 female) with chronic total occlusions (CTO) of the femoro-popliteal arteries presenting with CLI (17 patients with Rutherford 4 score, and 5 patients with Rutherford 5 score) were enrolled and successfully recanalized using the Pulsar-18 self-expanding (SE) nitinol stent (BIOTRONIK AG, Buelach, Switzerland). Primary patency at 12 months was defined as no binary restenosis (>50%) on Duplex ultrasound (PSVRPulsar-18 SE nitinol stent was 77% with a per protocol restenosis in 5 of 22 patients. Seventeen patients showed a walking capacity on treadmill test >300 meters (Rutherford II). Two patients with a documented restenosis were Rutherford, these patients were treated conservatively. Three patients with restenosis and a Rutherford III score were scheduled for an endovascular target lesion revascularization leading to a freedom from target lesion revascularization rate of 86%. Endovascular intervention of long SFA occlusions using subintimal or intraluminal recanalization technique with implantation of the Pulsar-18 SE nitinol stent in CLI patients is safe and clinically effective with a primary patency rate after 12 months of 77% and a freedom from target lesion revascularization rate of 86%.

  20. Comparison of Immediate and 2-Year Outcomes between Excimer Laser-Assisted Angioplasty with Spot Stent and Primary Stenting in Intermediate to Long Femoropopliteal Disease

    Directory of Open Access Journals (Sweden)

    Tien-Yu Wu

    2013-01-01

    Full Text Available Background. To compare the clinical outcomes between excimer laser-assisted angioplasty (ELA with spot stent (group A and primary stenting (group B in intermediate to long femoropopliteal disease. Methods. Outcomes of 105 patients totaling 119 legs treated with two different strategies were analyzed retrospectively in a prospectively maintained database. Results. Baseline characteristics were similar in both groups. Better angiographic results and lesser increase of serum C-reactive protein levels (0.60 ± 0.72 versus 2.98 ± 0.97 mg/dL, P<0.001 after the intervention were obtained in Group B. Group A had inferior 1-year outcomes due to higher rate of binary restenosis (67% versus 32%, P=0.001 and lower rate of primary patency (40% versus 58%, P=0.039. Rates of amputation-free survival, target vessel revascularization, assisted primary patency, and stent fracture at 24 months were similar in both groups (80% versus 82%, P=0.979, 65% versus 45%, P=0.11, 78% versus 80%, P=0.75 and 6.3% versus 6.8%, P=0.71, resp.. Conclusion. Greater vascular inflammation after ELA with spot stent resulted in earlier restenosis and inferior 1-year clinical outcomes than primary stenting. This benefit was lost in the primary stenting group at 2 years due to late catch-up restenosis. Active surveillance with prompt intervention was required to maintain the vessel patency.

  1. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  2. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  3. FFR-guided multivessel stenting reduces urgent revascularization compared with infarct-related artery only stenting in ST-elevation myocardial infarction: A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Gupta, Ankur; Bajaj, Navkaranbir S; Arora, Pankaj; Arora, Garima; Qamar, Arman; Bhatt, Deepak L

    2018-02-01

    Randomized controlled trials (RCTs) have shown fractional flow reserve-guided (FFR) multivessel stenting to be superior to infarct-related artery (IRA) only stenting in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease. This effect was mainly driven by a reduction in overall repeat revascularization. However, the ability to assess the effect of this strategy on urgent revascularization or reinfarction was underpowered in individual trials. We searched Pubmed, EMBASE, Cochrane CENTRAL, and Web of Science for RCTs of FFR-guided multivessel stenting versus IRA-only stenting in STEMI with multivessel disease. The outcomes of interest were death, reinfarction, urgent, and non-urgent repeat revascularization. Risk ratios (RR) were pooled using the DerSimonian and Laird random-effects model. After review of 786 citations, 2 RCTs were included. The pooled results demonstrated a significant reduction in the composite of death, reinfarction, or revascularization in the FFR-guided multivessel stenting group versus IRA-only stenting group (RR [95%, Confidence Interval]: 0.49 [0.33-0.72], p<0.001). This risk reduction was driven mainly by a reduction in repeat revascularization, both urgent (0.41 [0.24-0.71], p=0.002) and non-urgent revascularization (0.31 [0.19-0.50], p<0.001). Pooled RR for reinfarction was lower in the FFR-guided strategy, but was not statistically significant (0.71[0.39-1.31], p=0.28). This systematic review and meta-analysis suggests that a strategy of FFR-guided multivessel stenting in STEMI patients reduces not only overall repeat revascularization but also urgent revascularization. The effect on reinfarction needs to be evaluated in larger trials. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  4. Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a 188Re-MAG3-filled balloon: six-month clinical and angiographic results of R4 registry

    International Nuclear Information System (INIS)

    Moon, D. H.; Oh, S. J.; Park, S. W.; Hong, M. K.; Lee, C. H.; Kim, J. Z.; Park, S. J.; Lee, H. K.

    2000-01-01

    Intracoronary β-irradiation after rotational atherectomy may be a reasonable approach to prevent recurrent in-stent restenosis (ISR). This study was done to evaluate the feasibility and efficacy of β-radiation therapy with a 188 Re-MAG3-filled balloon following rotational atherectomy for ISR. Fifty consecutive patients with diffuse ISR (length >10 mm) in native coronary arteries underwent rotational atherectomy and adjunctive balloon angioplasty followed by β-irradiation using 188 Re-MAG3-filled balloon catheter. The radiation doses was 15 Gy at 1.0 mm deep into vessel wall. Mean length of the lesion and irradiated segment was 25.6±12.7 mm and 37.6±11.2 mm, respectively. The radiation was delivered successfully to all patients, with a mean irradiation time of 20.1±61 7 sec. No adverse event including myocardial infarction, death, or stent thrombosis occurred during the follow-up period (mean 10.3±3.7 mon) and non-target vessel revascularization was needed in one patient. Six-month binary angiographic restenosis rate was 10.4% (2 focal ISR and 3 edge restenosis) and loss index was 0.17±0.31. Irradiation using 188 Re-MAG3-filled balloon following rotational atherectomy for patients with diffuse ISR may improve the clinical and angiographic outcomes. Further prospective randomized trials are warranted to evaluate the synergistic effect of debulking and irradiation in patients with diffuse ISR

  5. DK mini-culotte stenting in the treatment of true coronary bifurcation lesions: a propensity score matching comparison with T-provisional stenting.

    Science.gov (United States)

    Fan, Lin; Chen, Lianglong; Luo, Yukun; Zhang, Linlin; Zhong, Wenliang; Lin, Chaogui; Chen, Zhaoyang; Peng, Yafei; Zhen, Xingchun; Dong, Xianfeng

    2016-03-01

    The conventional culotte technique remains not to be widely used for the treatment of coronary bifurcation lesions due to its inherent drawbacks. Here, we developed a double kissing mini-culotte stenting (DK mini-culotte) and assessed its efficacy and safety by a propensity score matching comparison (PSM) with T-provisional stenting. From June 2010 to June 2012, a total of 223 consecutive patients with true coronary bifurcation lesions (TCBLs) were treated with DK mini-culotte (91 patients with 92 lesions) or T-provisional stenting (132 patients with 135 lesions). We performed a PSM to correct the confounders from clinical and lesion's characteristics. The primary endpoint was cumulative major adverse cardiac event (MACE) at 1 year including cardiac death, myocardial infarction, and target vessel revascularization or target lesion revascularization (TVR/TLR). The secondary endpoint was the rate of side branch (SB) restenosis at 12 months. After a PSM, there were 66 patients in each group. Additional SB stenting in the T-provisional group was performed in 10 (15.2 %) lesions. The incidence of 1-year cumulative MACE was 4.55 % for the DK mini-culotte versus 13.6 % for T-provisional stenting (P = 0.127), the rate of TVR/TLR was 1.52 % for DK mini-culotte versus 12.12 % for T-provisional stenting (P = 0.033). The SB binary restenosis rate was 5.6 % in the DK mini-culotte group and 22.4 % in the T-provisional group (P = 0.014). In summary, despite that there is no difference in MACE between groups, DK mini-culotte significantly reduce TVR/TLR and SB restenosis in the treatment of true coronary bifurcation lesions.

  6. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  7. Treatment of diffuse in-stent restenosis with rotational atherectomy followed by radiation therapy with a {sup 188}Re-MAG3-filled balloon: six-month clinical and angiographic results of R4 registry

    Energy Technology Data Exchange (ETDEWEB)

    Moon, D. H.; Oh, S. J.; Park, S. W.; Hong, M. K.; Lee, C. H.; Kim, J. Z.; Park, S. J.; Lee, H. K. [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2000-07-01

    Intracoronary {beta}-irradiation after rotational atherectomy may be a reasonable approach to prevent recurrent in-stent restenosis (ISR). This study was done to evaluate the feasibility and efficacy of {beta}-radiation therapy with a {sup 188}Re-MAG3-filled balloon following rotational atherectomy for ISR. Fifty consecutive patients with diffuse ISR (length >10 mm) in native coronary arteries underwent rotational atherectomy and adjunctive balloon angioplasty followed by {beta}-irradiation using {sup 188}Re-MAG3-filled balloon catheter. The radiation doses was 15 Gy at 1.0 mm deep into vessel wall. Mean length of the lesion and irradiated segment was 25.6{+-}12.7 mm and 37.6{+-}11.2 mm, respectively. The radiation was delivered successfully to all patients, with a mean irradiation time of 20.1{+-}61 7 sec. No adverse event including myocardial infarction, death, or stent thrombosis occurred during the follow-up period (mean 10.3{+-}3.7 mon) and non-target vessel revascularization was needed in one patient. Six-month binary angiographic restenosis rate was 10.4% (2 focal ISR and 3 edge restenosis) and loss index was 0.17{+-}0.31. Irradiation using {sup 188}Re-MAG3-filled balloon following rotational atherectomy for patients with diffuse ISR may improve the clinical and angiographic outcomes. Further prospective randomized trials are warranted to evaluate the synergistic effect of debulking and irradiation in patients with diffuse ISR.

  8. Intravascular brachytherapy for peripheral vascular disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-09-01

    Full Text Available Scientific background: Percutaneous transluminal angioplasties (PTA through balloon dilatation with or without stenting, i.e. vessel expansion through balloons with or without of implantation of small tubes, called stents, are used in the treatment of peripheral artery occlusive disease (PAOD. The intravascular vessel irradiation, called intravascular brachytherapy, promises a reduction in the rate of repeated stenosis (rate of restenosis after PTA. Research questions: The evaluation addresses questions on medical efficacy, cost-effectiveness as well as ethic, social and legal implications in the use of brachytherapy in PAOD patients. Methods: A systematic literature search was conducted in August 2007 in the most important medical electronic databases for publications beginning from 2002. The medical evaluation included randomized controlled trials (RCT. The information synthesis was performed using meta-analysis. Health economic modeling was performed with clinical assumptions derived from the meta-analysis and economical assumptions derived from the German Diagnosis Related Groups (G-DRG-2007. Results: Medical evaluation: Twelve publications about seven RCT on brachytherapy vs. no brachytherapy were included in the medical evaluation. Two RCT showed a significant reduction in the rate of restenosis at six and/or twelve months for brachytherapy vs. no brachytherapy after successful balloon dilatation, the relative risk in the meta-analysis was 0.62 (95% CI: 0.46 to 0.84. At five years, time to recurrence of restenosis was significantly delayed after brachytherapy. One RCT showed a significant reduction in the rate of restenosis at six months for brachytherapy vs. no brachytherapy after PTA with optional stenting, the relative risk in the meta-analysis was 0.76 (95% CI: 0.61 to 0.95. One RCT observed a significantly higher rate of late thrombotic occlusions after brachytherapy in the subgroup of stented patients. A single RCT for brachytherapy

  9. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for

  10. Covered versus Uncovered Self-Expandable Metal Stents for Managing Malignant Distal Biliary Obstruction: A Meta-Analysis.

    Science.gov (United States)

    Li, Jinjin; Li, Tong; Sun, Ping; Yu, Qihong; Wang, Kun; Chang, Weilong; Song, Zifang; Zheng, Qichang

    2016-01-01

    To compare the efficacy of using covered self-expandable metal stents (CSEMSs) and uncovered self-expandable metal stents (UCSEMSs) to treat objective jaundice caused by an unresectable malignant tumor. We performed a comprehensive electronic search from 1980 to May 2015. All randomized controlled trials comparing the use of CSEMSs and UCSEMSs to treat malignant distal biliary obstruction were included. The analysis included 1417 patients enrolled in 14 trials. We did not detect significant differences between the UCSEMS group and the CSEMS group in terms of cumulative stent patency (hazard ratio (HR) 0.93, 95% confidence interval (CI) 0.19-4.53; p = 0.93, I2 = 0%), patient survival (HR 0.77, 95% CI 0.05-10.87; p = 0.85, I2 = 0%), overall stent dysfunction (relative ratio (RR) 0.85, M-H, random, 95% CI 0.57-1.25; p = 0.83, I2 = 63%), the overall complication rate (RR 1.26, M-H, fixed, 95% CI 0.94-1.68; p = 0.12, I2 = 0%) or the change in serum bilirubin (weighted mean difference (WMD) -0.13, IV fixed, 95% CI 0.56-0.3; p = 0.55, I2 = 0%). However, we did detect a significant difference in the main causes of stent dysfunction between the two groups. In particular, the CSEMS group exhibited a lower rate of tumor ingrowth (RR 0.25, M-H, random, 95% CI 0.12-0.52; p = 0.002, I2 = 40%) but a higher rate of tumor overgrowth (RR 1.76, M-H, fixed, 95% CI 1.03-3.02; p = 0.04, I2 = 0%). Patients with CSEMSs also exhibited a higher migration rate (RR 9.33, M-H, fixed, 95% CI 2.54-34.24; p = 0.008, I2 = 0%) and a higher rate of sludge formation (RR 2.47, M-H, fixed, 95% CI 1.36-4.50; p = 0.003, I2 = 0%). Our meta-analysis indicates that there is no significant difference in primary stent patency and stent dysfunction between CSEMSs and UCSEMSs during the period from primary stent insertion to primary stent dysfunction or patient death. However, when taking further management for occluded stents into consideration, CSEMSs is a better choice for patients with malignant biliary

  11. Endovascular Versus Open Surgical Intervention in Patients with Takayasu's Arteritis: A Meta-analysis.

    Science.gov (United States)

    Jung, Jae Hyun; Lee, Young Ho; Song, Gwan Gyu; Jeong, Han Saem; Kim, Jae-Hoon; Choi, Sung Jae

    2018-06-01

    Although medical treatment has advanced, surgical treatment is needed to control symptoms of Takayasu's arteritis (TA), such as angina, stroke, hypertension, or claudication. Endovascular or open surgical intervention is performed; however, there are few comparative studies on these methods. This meta-analysis and systematic review aimed to examine the outcome of surgical treatment of TA. A meta-analysis comparing outcomes of endovascular and open surgical intervention was performed using MEDLINE and Embase. This meta-analysis included only observational studies, and the evidence level was low to moderate. Data were pooled and analysed using a fixed or random effects model with the I 2 statistic. The included studies involved a total of 770 patients and 1363 lesions, with 389 patients treated endovascularly and 420 treated by surgical revascularization. Restenosis was more common with endovascular than open surgical intervention (odds ratio [OR] 5.18, 95% confidence interval [CI] 2.78-9.62; p open surgical intervention patients in the coronary artery, supra-aortic branches, and renal artery. In both the active and inactive stages, restenosis was more common in those treated endovascularly than in those treated by open surgery. However, stroke occurred less often with endovascular intervention than with open surgical intervention (OR 0.33, 95% CI 0.12-0.90; p = .003). Mortality and complications other than stroke and mortality did not differ between endovascular and open surgical intervention. This meta-analysis has shown a lower risk of restenosis with open surgical intervention than with endovascular intervention. Stroke was generally more common with open surgical intervention than with endovascular intervention. However, there were differences according to the location of the lesion, and the risk of stroke in open surgery is higher when the supra-aortic branches are involved rather than the renal arteries. Copyright © 2018 European Society for Vascular

  12. Radioactive self-expanding stents for palliative management of unresectable esophageal cancer: a systematic review and meta-analysis.

    Science.gov (United States)

    Chen, Hong-Lin; Shen, Wang-Qin; Liu, Kun

    2017-05-01

    Stent insertion is a feasible and safe palliative management for advanced unresectable esophageal cancer. The aim of this study is to assess the efficacy of radioactive stent for unresectable esophageal cancer compared with conventional stent. Systematic searches of the PubMed and Web of science are dated from their beginning to January 25, 2016. Studies that compared radioactive stent with conventional stent for unresectable esophageal cancer were included. The outcomes were postimplantation survival, relief of dysphagia, and complications related to stent implant. Six studies with 539 patients were included. All of them used stent equipped with radioactive iodine beads as a radioactive stent. The pooled weighted mean difference for median survival was 2.734 months (95% CI 1.710-3.775; Z = 5.21, P = 0.000) between two groups. The 1,3,6 month survival rates were higher in radioactive stents than conventional stent, with the pooled ORs 3.216 (95% CI 1.293-7.999; Z = 2.51, P = 0.012), 3.095 (95% CI 1.908-5.020; Z = 4.58, P = 0.000), and 7.503 (95% CI 2.206- 25.516; Z = 3.23, P = 0.001, respectively). The pooled hazard ratio was 0.464 (95% CI 0.328-0.655; Z = 4.35, P = 0.000) between two groups. For relief of dysphagia, two stents all have good relief of the dysphagia effect, but radioactive stent showed a better effect at 3, 6 months follow-up after implantation. For complications related to stent implant, no significant differences were found between two stents in terms of severe chest pain (30.0% vs. 35.7%, OR 0.765, 95% CI 0.490-1.196), gastroesophageal reflux (18.6% vs. 16.1%, OR 1.188, 95% CI 0.453-3.115), fever (12.1% vs. 12.1%, OR 1.014, 95% CI 0.332-3.097), bleeding (16.7% vs. 14.2%, OR 1.201, 95% CI 0.645-2.236), perforation or fistula (6.1% vs. 9.0%, OR 0.658, 95% CI 0.291-1.486), pneumonia (10.7% vs. 14.1%, OR 0.724, 95% CI 0.343-1.526), stent migration (7.0% vs. 10.2%, OR 0.651, 95% CI 0.220-1.924), and restenosis (24.2% vs. 20.6%, OR 1.228, 95% CI 0

  13. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  14. Technological Advances in Stent Therapies: a Year in Review.

    Science.gov (United States)

    Raffoul, Jad; Nasir, Ammar; Klein, Andrew J P

    2018-04-07

    Stent technology has rapidly evolved since the first stainless steel bare metal stents with substantial developments in scaffolding, polymer, drug choice, drug delivery, and elution mechanisms. Most recently, there has been the evolution of bioabsorbable vascular scaffolds, potentially eliminating the need for long-term foreign object retention. These rapid developments have led to an ever-expanding selection of new stents, making the choice of which to use in which patient challenging. Operators must balance potential short- and long-term clinical ramifications, namely stent thrombosis, in-stent restenosis, target lesion revascularization, and target lesion failure. In this review, we hope to provide insight for interventional cardiologists on the details of stent technology and how this impacts outcomes, stent selection, and duration of dual-antiplatelet therapy duration post drug-eluting stent implantation.

  15. Clinical evaluation of domestic biodegradable drug-eluting stents in the treatment of coronary heart disease

    International Nuclear Information System (INIS)

    Yu Hongying; Suo Chuantao; Shang Ruiping

    2009-01-01

    Objective: To evaluate the safety and efficacy of domestic biodegradable drug-eluting stent, EXCEL, in clinical treatment of coronary heart disease. Methods: During the period of Jan. 2008-Oct. 2008, 100 patients with coronary heart disease who consented to PCI and postoperative coronary angiography were selected and enrolled in the study. The patients were divided into EXCEL group (n = 58) and Cypher group (n = 42). The immediate successful rate of interventional therapy and the complications occurred during hospitalization were observed. Postoperative follow-up and checkup coronary angiography were conducted. Results: No significant difference in the relevant clinical data, in the number and type of diseased coronary branch and in the mean length of implanted stents existed between two groups. Also, no statistically significant difference in the occurrence of major adverse cardiac event (MACE), in-stent restenosis and thrombosis was present between two groups. Conclusion: Compared with Cypher stenting, EXCEL stenting carries similar, i.e. rather low, occurrence of MACE and in-stent restenosis. (authors)

  16. Symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) with concurrent contralateral vertebral atherosclerotic diseases in 88 patients treated with the intracranial stenting

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zi-Liang [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Gao, Bu-Lang [Department of Medical Research Shijiazhuang First Hospital, Hebei Medical University (China); Li, Tian-Xiao, E-mail: litianxiaod@163.com [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China); Cai, Dong-Yang; Zhu, Liang-Fu; Bai, Wei-Xing; Xue, Jiang-Yu; Li, Zhao-Shuo [Stroke Center, Henan Provincial People’s Hospital, Zhengzhou University (China)

    2015-09-15

    Highlights: • Symptomatic vertebral artery stenosis can be treated with intracranial stenting. • Stenting for intracranial vertebral artery stenosis is safe and effective. • Stenting for intracranial vertebral artery stenosis can prevent long-term stroke. - Abstract: Purpose: To investigate the safety, effect and instent restenosis rate of Wingspan stenting in treating patients with intracranial vertebral artery atherosclerotic stenosis (70–99%) concurrent with contralateral vertebral artery atherosclerotic diseases. Materials and methods: Eighty-eight patients with severe symptomatic intracranial vertebral artery atherosclerotic stenosis (≥70%) combined with contralateral vertebral artery atherosclerotic diseases were treated with the Wingpsan stent. All the baseline, cerebral angiography, success rate, perioperative complications, clinical and imaging follow-up data were prospectively analyzed. Results: The success rate of stenting was 100%, and the mean stenotic rate was reduced from prestenting (84.9 ± 6.8)% to poststenting (17.2 ± 5.9)%. The perioperative stroke rate was 1.1%. Among eighty patients (90.9%) with clinical follow-up 8-62 months (mean 29.3 ± 17.2) poststenting, five (6.3%) had posterior circulation TIA only, three (3.8%) had mild stroke in the posterior circulation but recovered completely, and another five patients greater than 70 years old died of non-ischemic stroke. Imaging follow-up in 46 patients (52.3%) 5–54 months (mean 9.9 ± 9.9) following stenting revealed instent restenosis in 12 patients (26.1%) including 7 (58.3%) symptomatic restenosis. Age and residual stenosis were the two factors to significantly (P < 0.05) affect instent restenosis. Conclusion: Wingspan stenting in the intracranial vertebral artery atherosclerotic stenosis combined with contralateral vertebral artery atherosclerotic diseases has a low perioperative stroke rate and a good preventive effect on long-term ischemic stroke, but the instent restenosis

  17. The current role of vascular stents.

    Science.gov (United States)

    Busquet, J

    1993-09-01

    The limitations of percutaneous balloon angioplasty have favoured the development and the use of vascular endoprostheses or stents. These thin-walled metal devices maintain after expansion, an optimal and constant diameter for the vascular lumen. Restenosis, dissection, abrupt closure, residual stenosis or re-opened total occlusion represent appropriate indications for stenting. A large experience with non-coronary application of stents is currently available in iliac, femoro-popliteal and renal arteries, aorta, large veins.

  18. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Ahmed, Ahmed T.; Mohammed, Khaled; Chehab, Monzer; Brinjikji, Waleed; Hassan Murad, M.; Cloft, Harry; Bjarnason, Haraldur

    2016-01-01

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  19. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed T., E-mail: Ahmed.Ahmed1@mayo.edu; Mohammed, Khaled, E-mail: Mohammed.Khaled@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Chehab, Monzer, E-mail: moe.chehab@beumont.edu [Oakland University William Beaumont School of Medicine, Department of Diagnostic Radiology and Molecular Imaging (United States); Brinjikji, Waleed, E-mail: Brinjikji.Waleed@mayo.edu [Mayo Clinic, Department of Radiology (United States); Hassan Murad, M., E-mail: Murad.Mohammad@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Cloft, Harry, E-mail: Cloft.Harry@mayo.edu; Bjarnason, Haraldur, E-mail: Bjarnason.Haraldur@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-05-15

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  20. Gianturco metallic biliary stent in malignant biliary obstruction: results of follow-up in dead patients

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, Chan Soo; Lee, Kyung Soo; Choi, See Sung; Won, Jong Jin; Kim, Haak Cheul; Chae, Kwon Mook [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1994-04-15

    In order to study the patency, restenosis, efficacy, and complication of the metallic stent in the course of treatment of malignant biliary obstruction, the results of follow up of the dead patients after stent insertion were reviewed. Self-expandable Gianturco metallic stent with 10-mm diameter was successfully inserted in 33 patients: 10 with Klatskin tumor, 7 with common bile duct cancer, 7 with gallbladder cancer, 5 with pancreatic cancer, 2 with recurred stomach cancer, one with periampullary cancer, one with hepatocellular carcinoma. The overall duration of survival and patency of the stents in 33 patients were 5.2 months(1-12 months) and 4.9 months(1-14 months), respectively. Restenosis of metallic stents was found in 9 cases(27%), after 6.1 months in average. Causes of stent occlusion were overgrowing of tumor in 5, overgrowing and ingrowing of tumor in 3, extraductal dislodgement in one case. Two cases of symptomatic cholangitis after stent placement were successfully treated with percutaneous cholecystostomy. Three cases of destruction and migration of metallic stents were found after 6 months. On the basis of our experience, insertion of Gianturco metallic biliary stent is an acceptable treatment method in the malignant biliary obstruction, especially for whom short term survival is expected.

  1. JetStream Rotational and Aspiration Atherectomy in Treating In-Stent Restenosis of the Femoropopliteal Arteries: Results of the JETSTREAM-ISR Feasibility Study.

    Science.gov (United States)

    Shammas, Nicolas W; Shammas, Gail A; Banerjee, Subhash; Popma, Jeffrey J; Mohammad, Atif; Jerin, Michael

    2016-04-01

    To evaluate the outcomes and stent-device interaction of the JetStream atherectomy device in the treatment of in-stent restenosis (ISR) of the femoropopliteal segment. The JetStream XC atherectomy device, a rotational cutter with aspiration capacity, was evaluated in a prospective cohort of 29 patients (mean age 69.9 ± 11.7 years; 11 men) with femoropopliteal ISR in 32 limbs (ClinicalTrials.gov identifier NCT01722877). Lesion length was 17.4 ± 13.1 cm. The primary effectiveness outcome was acute success (≤ 30% residual narrowing with no serious adverse events). The primary safety endpoint was major adverse events. Secondary endpoints included clinically driven target lesion revascularization (TLR) at 6 months and 1 year and loss of stent integrity as assessed by an angiographic core laboratory. Treated length was 19.5 ± 12.9 cm. Acute success was obtained in 29/32 (91%) limbs. Acute device success (atherectomy alone) was 76% (22/29). Adjunctive balloon angioplasty was performed in all cases at a mean pressure of 11.6 ± 3.3 atm. Embolic filter protection was used in 16 (50%) of 32 limbs. Macrodebris was noted in 2 (12%) of 16 filters. Distal embolization requiring treatment occurred in 3/32 (9.4%) limbs (2 with no filter). Other non-procedure-related adverse events were 1 (3%) death (nonvascular) and 1 (3%) case of major bleeding. There were no new stent fractures or deformities (n=24) postatherectomy. Follow-up was completed on 27 patients (29 limbs) at 6 and 12 months. TLR at these time points occurred in 4/29 (14%) and 12/29 (41%) patients. Patency (duplex-derived peak systolic velocity ratio atherectomy using the XC device has favorable acute results in treating femoropopliteal ISR with high procedure success, no device-stent interaction, and favorably low TLR rates. A multicenter trial is needed to confirm these results. © The Author(s) 2016.

  2. Number of Blades-up Runs Using JetStream XC Atherectomy for Optimal Tissue Debulking in Patients with Femoropopliteal Artery In-Stent Restenosis.

    Science.gov (United States)

    Shammas, Nicolas W; Shammas, Gail A; Aasen, Nicole; Jarvis, Gary

    2015-12-01

    Rotational atherectomy with the use of the JetStream XC device is indicated for treatment of infrainguinal arterial obstructive disease. The number of blades-up (BU) runs needed for optimal tissue debulking in femoropopliteal in-stent restenosis (ISR) is unknown. In the present series, 6 patients (15 lesions) were treated for femoropopliteal ISR with the JetStream XC device. Minimal luminal diameter or percent stenosis improved significantly from baseline after 2 BU runs, but no further gain was seen between 2 and 4 BU runs (P > .05). However, adjunctive balloon angioplasty reduced percent stenosis significantly following BU runs. In conclusion, the JetStream XC device achieved optimal acute angiographic results in treating femoropopliteal ISR following 2 BU runs and adjunctive balloon angioplasty. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  3. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  4. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease A Meta-Analysis of Individual Patient Data

    NARCIS (Netherlands)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W.; Park, Seung-Jung

    2016-01-01

    OBJECTIVES The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD).

  5. Differences in patient selection and outcomes between SilverHawk atherectomy and laser ablation in the treatment of femoropopliteal in-stent restenosis: a retrospective analysis from a single center.

    Science.gov (United States)

    Shammas, Nicolas W; Shammas, Gail A; Jerin, Michael

    2013-12-01

    To analyze differences in the application and outcomes of SilverHawk atherectomy (SH) and excimer laser ablation (ELA) in the treatment of femoropopliteal in-stent restenosis (ISR) in an unselected cohort of patients treated at a single center. Between January 2005 and June 2010, 81 consecutive patients (46 men; mean age 69.1 years, range 43-86) underwent directional atherectomy (41 SH, 40 ELA) for femoropopliteal ISR lesions. Data were reviewed retrospectively on procedural outcomes, major adverse events, and 1-year target lesion revascularization (TLR) obtained from medical records and supplemented with telephone calls. The primary endpoint was symptom-driven TLR at 1 year; secondary endpoints were death and amputation. ELA was utilized more frequently than SH in longer lesions (210.4±104 vs. 126.2±79.3 mm, respectively; p=0.001), subacute presentation (55% vs. 14.6%, p=0.001), TASC D lesions (47.5% vs. 12.2%), and in patients with more angiographic thrombus (42.5% vs. 4.9%, p=0.001). Final angiographic success (<30% residual narrowing post final treatment) was similar between ELA and SH (92.5% vs. 100%, respectively, p=0.12). Bailout stenting was significantly higher with ELA vs. SH (50.0% vs. 24.4%, p=0.022). At 1 year, TLR had occurred in 48.7% of the ELA patients vs. 31.7% of the SH cases (p=0.171). Regression analysis confirmed that SH was a predictor of TLR at 1 year (hazard ratio 2.679, 95% CI 1.015 to 7.073, p=0.047). Both SH and ELA continue to have a high TLR rate in treating ISR of the femoral and popliteal arteries. A higher rate of delayed failure is seen with SH and an earlier, steeper loss of TLR-free survival is seen with ELA.

  6. Pulmonary Arterial Stent Implantation in an Adult with Williams Syndrome

    International Nuclear Information System (INIS)

    Reesink, Herre J.; Henneman, Onno D. F.; Delden, Otto M. van; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-term follow-up showed a good clinical result with excellent patency of the stents but early restenosis of the segments in which only balloon angioplasty was performed. These stenoses were subsequently also treated successfully by stent implantation. Stent patency was observed 3 years after the first procedure

  7. Comparison of zotarolimus-eluting and everolimus-eluting coronary stents

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Silber, Sigmund; Garg, Scot

    2010-01-01

    New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed...

  8. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  9. Stent implantation influence wall shear stress evolution

    Science.gov (United States)

    Bernad, S. I.; Totorean, A. F.; Bosioc, A. I.; Petre, I.; Bernad, E. S.

    2016-06-01

    Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.

  10. Mechanical thrombectomy using Rotarex system and stent-in-stent placement for treatment of distal femoral artery occlusion secondary to stent fracture – a case report and literature review

    International Nuclear Information System (INIS)

    Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech

    2013-01-01

    Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients

  11. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na [Chonnam Univ. College of Medicine, Kwangju (Korea, Republic of)

    1999-04-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate.

  12. Hemodialysis shunts-related subclavian vein stenosis : treatment with self-expandable metallic stent

    International Nuclear Information System (INIS)

    Kim, Sang Gyee; Lee, Young Chul; Shin, Sang Soo; Kim, Yun Hyeon; Kim, Jae Kyu; Kang, Heoung Keun; Jeong, Sang Young; Choi, Su Jin Na

    1999-01-01

    To evaluate the usefulness of placement of self-expandable stents in hemodialytic shunt-related subclavian vein stenosis. Self-expandable metallic stent was placed in nine patients with hemodialytic shunt-related subclavian vein stenosis. In seven cases, angioplasty was attempted before stent placement; in five, stents were placed immediately after failed angioplasty; and in two, due to restenosis after angioplasty. Procedures involved a 10mm diameter, 7-10cm length Wallstent in eight cases, and a 10mm diameter, 8cm length Hanaro stent in one. In all cases, clinical follow-up, which included physical examination and the measurement of venous resistance pressure during hemodialysis, was performed. The follow-up period was between 5 months and 1 year 7 months. Repeated intervention was performed if restenosis was detected. The stenotic sites were in eight cases the site of a previous subclavian venous line, and in one, the site of anatomic narrowing at the thoracic inlet of the subclavian vein. The technical success rate was 100%;a resulting complication was stent migration into the right atrium in one case in which a Hanaro stent had been used; this was removed by snaring. During follow-up of the eight patients in whon stent placement was successful, restenosis developed in three cases. This occurred during the 7th, 8th, and 15th month, respectively. Two such cases were treated by balloon dilatation. In hemodialytic shunt-related subclavian vein stenosis, treatment involving the use of a self-expandable metallic stent is useful, especially for treating a lesion which has not responded to angioplasty with a high patency rate

  13. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    Science.gov (United States)

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Directional Atherectomy in Iliac Stent Failure: Clinical Technique and Histopathologic Correlation

    International Nuclear Information System (INIS)

    Ettles, Duncan F.; MacDonald, Alastair W.; Burgess, Paul A.; Nicholson, Anthony A.; Dyet, John F.

    1998-01-01

    Purpose: To assess the feasibility and efficacy of directional atherectomy in the treatment of iliac stent stenosis or occlusion and to evaluate the histologic composition of excised atherectomy specimens. Methods: Directional atherectomy of six occluded and 10 severely stenosed iliac stents was undertaken in 12 patients at a mean interval of 28 months (range 3-69 months) after stent insertion for occlusive aortoiliac disease. In cases of stent occlusion, atherectomy was preceded by low-dose thrombolysis. In all patients stent clearance with return of femoral pulses was achieved within 24 hr and there were no significant complications. All excised specimens were sent for histologic examination. Results: Eleven patients (92%) remain symptom free with unlimited walking distance at a mean follow-up interval of 11.5 months (range 3-31 months) after treatment. Histologic examination revealed typical myointimal hyperplasia at three excision sites, intimal fibrosis at three sites, atheroma at four sites and organized thrombus at six sites. Conclusion: Atherectomy offers an effective treatment in iliac stent occlusion and restenosis with no significant adverse effects. Debulking of these lesions seems to offer a more logical approach than simple balloon angioplasty. Clinical and duplex follow-up confirms satisfactory outcome within the first year but longer-term results are not yet known. The histologic data obtained demonstrate that stent restenosis and occlusion are likely to be multifactorial, and challenge the assumption that myointimal hyperplasia is the sole cause of iliac stent occlusion

  15. Comparison of clinical outcomes after drug-eluting balloon and drug-eluting stent use for in-stent restenosis related acute myocardial infarction: a retrospective study

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Fang

    2018-04-01

    Full Text Available Background Good results of drug-eluting balloon (DEB use are achieved in in-stent restenosis (ISR lesions, small vessel disease, long lesions, and bifurcations. However, few reports exist about DEB use in acute myocardial infarction (AMI with ISR. This study’s aim was to evaluate the efficacy of DEB for AMI with ISR. Methods Between November 2011 and December 2015, 117 consecutive patients experienced AMI including ST-segment elevation MI, and non-ST-segment elevation MI due to ISR, and received percutaneous coronary intervention (PCI. We divided our patients into two groups: (1 PCI with further DEB, and (2 PCI with further drug-eluting stent (DES. Clinical outcomes such as target lesion revascularization, target vessel revascularization, recurrent MI, stroke, cardiovascular mortality, and all-cause mortality were analyzed. Results The patients’ average age was 68.37 ± 11.41 years; 69.2% were male. A total of 75 patients were enrolled in the DEB group, and 42 patients were enrolled in the DES group. The baseline characteristics between the two groups were the same without statistical differences except for gender. Peak levels of cardiac biomarker, pre- and post-PCI cardiac function were similar between two groups. The major adverse cardiac cerebral events rate (34.0% vs. 35.7%; p = 0.688 and cardiovascular mortality rate (11.7% vs. 12.8%; p = 1.000 were similar in both groups. Conclusions DEB is a reasonable strategy for AMI with ISR. Compared with DES, DEB is an alternative strategy which yielded acceptable short-term outcomes and similar 1-year clinical outcomes.

  16. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    Science.gov (United States)

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  17. Solving the Issue of Restenosis After Stenting of Intracranial Stenoses: Experience with Two Thin-Strut Drug-Eluting Stents (DES)—Taxus Element™ and Resolute Integrity™

    Energy Technology Data Exchange (ETDEWEB)

    Kurre, Wiebke, E-mail: wiebke.kurre@gmx.de; Aguilar-Pérez, Marta [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany); Fischer, Sebastian [Universitätsklinikum Knappschaftskrankenhaus Bochum GmbH, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin (Germany); Arnold, Guy [Klinikverbund Südwest, Klinikum Sindelfingen, Klinik für Neurologie (Germany); Schmid, Elisabeth; Bäzner, Hansjörg [Klinikum Stuttgart, Klinik für Neurologie (Germany); Henkes, Hans [Klinikum Stuttgart, Klinik für Diagnostische und Interventionelle Neuroradiologie (Germany)

    2015-06-15

    PurposeThin-strut, flexible DES are suitable for intracranial stenting and may improve long-term vessel patency. The purpose of this study was to report our experience with two new-generation DES for the treatment of intracranial atherosclerotic disease.Patients and MethodsWe retrospectively reviewed all patients treated with Taxus Element™ or Resolute Integrity™ stent for an intracranial atherosclerotic stenosis between March 2011 and August 2013. Technical success was defined as the ability to deploy the device at the desired location and reduce the degree of stenosis below 50 %. All procedure-related strokes were recorded. Control angiography was scheduled after 6 weeks, 3, 6, and 12 months and yearly thereafter. A luminal narrowing ≥50 % was regarded as a restenosis. Stroke recurrence in the territory of the treated artery was reported.ResultsIn the defined period we treated 101 patients harboring 117 intracranial stenoses. The procedure was successful in 100 (85.5 %) lesions. Procedure-related strokes occurred in 10 (9.9 %) patients with a permanent morbidity in 3 (3.0 %). Follow-up angiography was available for 83 of 100 (83.0 %) successfully treated lesions with an average of 355 days (IQR 153–482 days). Three (3.6 %) asymptomatic restenoses were detected. All occurred after treatment with Resolute Integrity™, none after Taxus Element™ (p = 0.059). New strokes in the territory of the treated artery were encountered in 2 (2.6 %) occasions.ConclusionThin-strut DES improve long-term patency and reduce the risk of subsequent stroke. Differences between devices may exist. Feasibility is comparable to bare-metal balloon-mounted stents and procedure-related strokes occurred within the expected range.

  18. Silicon-carbide coated coronary stents have low platelet and leukocyte adhesion during platelet activation

    NARCIS (Netherlands)

    Monnink, SHJ; van Boven, AJ; Tigchelaar, [No Value; de Kam, PJ; Crijns, HJGM; van Oeveren, W

    Background: Stent thrombosis and restenosis are of great clinical significance. We constructed a closed loop in vitro heparinized whole human blood circulation model for testing hemocompatibility of coronary stents, This model allows evaluation of human blood activation by blood-stent interaction in

  19. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...... of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients....

  20. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    Science.gov (United States)

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  1. Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents.

    Science.gov (United States)

    Galvin, Emmet; Cummins, Christy; Yoshihara, Shoichiro; Mac Donald, Bryan J; Lally, Caitríona

    2017-08-01

    Magnesium stents are a promising candidate in the emerging field of absorbable metallic stents (AMSs). In this study, the mechanical and corrosion performance of dog-bone specimens and a specific stent design of a magnesium alloy, WE43, are assessed experimentally in terms of their corrosion behaviour and mechanical integrity. It is shown that plastic strains that are induced in the struts of the stent during stent deployment have a critical influence in directing subsequent corrosion behaviour within the material. In addition, the deployment and scaffolding characteristics of the magnesium stent are elucidated and contrasted with those of a commercial stainless steel stent. The magnesium stent is found to support higher levels of cyclic strain amplitude than the stainless steel stent, even prior to degradation, and this may play a role in reducing in-stent restenosis. This study provides new insights into the experimental performance of a current AMS design and material whilst demonstrating the critical influence of plastic strain on the corrosion performance and scaffolding ability of an AMS.

  2. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  3. Clinical outcomes with drug-eluting and bare-metal stents in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego

    2013-01-01

    The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis.......The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis....

  4. The beneficial effect of alpha-blockers for ureteral stent-related discomfort: systematic review and network meta-analysis for alfuzosin versus tamsulosin versus placebo.

    Science.gov (United States)

    Kwon, Jong Kyou; Cho, Kang Su; Oh, Cheol Kyu; Kang, Dong Hyuk; Lee, Hyungmin; Ham, Won Sik; Choi, Young Deuk; Lee, Joo Yong

    2015-06-24

    This study was carried out a network meta-analysis of evidence from randomized controlled trials (RCTs) to evaluate stent-related discomfort in patients with alfuzosin or tamsulosin versus placebo. Relevant RCTs were identified from electronic databases. The proceedings of appropriate meetings were also searched. Seven articles on the basis of RCTs were included in our meta-analysis. Using pairwise and network meta-analyses, comparisons were made by qualitative and quantitative syntheses. Evaluation was performed with the Ureteric Stent Symptoms Questionnaire to assess the urinary symptom score (USS) and body pain score (BPS). One of the seven RCTs was at moderate risk of bias for all quality criteria; two studies had a high risk of bias. In the network meta-analysis, both alfuzosin (mean difference [MD];-4.85, 95 % confidence interval [CI];-8.53--1.33) and tamsulosin (MD;-8.84, 95 % CI;-13.08--4.31) showed lower scores compared with placebo; however, the difference in USS for alfuzosin versus tamsulosin was not significant (MD; 3.99, 95 % CI;-1.23-9.04). Alfuzosin (MD;-5.71, 95 % CI;-11.32--0.52) and tamsulosin (MD;-7.77, 95 % CI;-13.68--2.14) showed lower scores for BPS compared with placebo; however, the MD between alfuzosin and tamsulosin was not significant (MD; 2.12, 95 % CI;-4.62-8.72). In the rank-probability test, tamsulosin ranked highest for USS and BPS, and alfuzosin was second. The alpha-blockers significantly decreased USS and BPS in comparison with placebo. Tamsulosin might be more effective than alfuzosin.

  5. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  6. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Weber, W.; Mayer, T.E.; Henkes, H.; Kis, B.; Hamann, G.F.; Holtmannspoetter, M.; Brueckmann, H.; Kuehne, D.

    2005-01-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  7. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  8. The effects of dextromethorphan on the outcome of percutaneous coronary intervention with bare-metal stent implantation

    Directory of Open Access Journals (Sweden)

    Wen-Cheng Liu

    2018-01-01

    Full Text Available Background: In the era of drug-eluting stents, although bare-metal stent (BMS remains an option for percutaneous coronary intervention (PCI, restenosis remains the Achilles' heel of BMS implantation. A recent study demonstrated several pleiotropic anti-inflammatory effects of dextromethorphan (DXM. This study aims to evaluate the effects of DXM on the outcome of PCI with BMS implantation.Methods: In this prospective, double-blind, randomized trial, we enrolled 55 patients who underwent PCI with BMS implantation from May 2006 to February 2009. The patients were divided into DXM (60 mg once daily and placebo groups. We compared mortality rates, myocardial infarction (MI, target lesion revascularization (TLR, restenosis, stent thrombosis, and plasma levels of high-sensitivity C-reactive protein (hs-CRP with repeated coronary angiography 6 months after the initial procedure.Results: During the 6-month follow-up period, no events of death, MI and stent thrombosis were reported in both groups. The TLR rate was 16.7% in patients receiving DXM compared to 24% receiving a placebo (P = 0.521. The restenosis rate was 30% in patients receiving DXM as compared to 40% receiving the placebo (P = 0.571. Although nonsignificant, the percentage of hs-CRP elevation was lower in the DXM group (20% compared to the placebo group 32%; P = 0.363.Conclusions: DXM is safe to use in patients who underwent PCI. Although DXM therapy following BMS implantation did not significantly reduce the TLR and restenosis rates, it implied a trend toward a lower TLR and restenosis and reduced inflammation in the DXM group compared to the placebo group. Nonetheless, further extensive studies are warranted to elucidate the anti-restenosis effects of DXM.

  9. A Novel Stent Coated with Antibodies to Endoglin Inhibits Neointimal Formation of Porcine Coronary Arteries

    Directory of Open Access Journals (Sweden)

    Song Cui

    2014-01-01

    Full Text Available Endoglin/CD105 is an accessory protein of the transforming growth factor-β receptor system that plays a critical role in proliferation of endothelial cells and neovasculature. Here, we aimed to assess the effect of novel stents coated with antibodies to endoglin (ENDs on coronary neointima formation. Thirty ENDs, thirty sirolimus-eluting stents (SESs, and thirty bare metal stents (BMSs were randomly assigned and placed in the coronary arteries in 30 juvenile pigs. Histomorphometric analysis and scanning electron microscopy were performed after stent implantation. Our results showed that after 7 days, there was no difference in the neointimal area and percent area stenosis in ENDs compared with SMSs or BMSs. After 14 days, the neointima area and percent area stenosis in ENDs were markedly decreased than those in BMSs or SESs (P<0.05. Moreover, the percentage of reendothelialization was significantly higher in ENDs than that in SESs or BMSs (P<0.01 at 7 and 14 days. The artery injury and the inflammation scores were similar in all groups at 7 and 14 days. In conclusion, our results demonstrated for the first time to our knowledge that endoglin antibody-coated stents can markedly reduce restenosis by enhancing reendothelialization in the porcine model and potentially offer a new approach to prevent restenosis.

  10. An agent-based model of the response to angioplasty and bare-metal stent deployment in an atherosclerotic blood vessel.

    Directory of Open Access Journals (Sweden)

    Antonia E Curtin

    Full Text Available PURPOSE: While animal models are widely used to investigate the development of restenosis in blood vessels following an intervention, computational models offer another means for investigating this phenomenon. A computational model of the response of a treated vessel would allow investigators to assess the effects of altering certain vessel- and stent-related variables. The authors aimed to develop a novel computational model of restenosis development following an angioplasty and bare-metal stent implantation in an atherosclerotic vessel using agent-based modeling techniques. The presented model is intended to demonstrate the body's response to the intervention and to explore how different vessel geometries or stent arrangements may affect restenosis development. METHODS: The model was created on a two-dimensional grid space. It utilizes the post-procedural vessel lumen diameter and stent information as its input parameters. The simulation starting point of the model is an atherosclerotic vessel after an angioplasty and stent implantation procedure. The model subsequently generates the final lumen diameter, percent change in lumen cross-sectional area, time to lumen diameter stabilization, and local concentrations of inflammatory cytokines upon simulation completion. Simulation results were directly compared with the results from serial imaging studies and cytokine levels studies in atherosclerotic patients from the relevant literature. RESULTS: The final lumen diameter results were all within one standard deviation of the mean lumen diameters reported in the comparison studies. The overlapping-stent simulations yielded results that matched published trends. The cytokine levels remained within the range of physiological levels throughout the simulations. CONCLUSION: We developed a novel computational model that successfully simulated the development of restenosis in a blood vessel following an angioplasty and bare-metal stent deployment based on

  11. Real-Time Electrical Bioimpedance Characterization of Neointimal Tissue for Stent Applications

    Directory of Open Access Journals (Sweden)

    David Rivas-Marchena

    2017-07-01

    Full Text Available To follow up the restenosis in arteries stented during an angioplasty is an important current clinical problem. A new approach to monitor the growth of neointimal tissue inside the stent is proposed on the basis of electrical impedance spectroscopy (EIS sensors and the oscillation-based test (OBT circuit technique. A mathematical model was developed to analytically describe the histological composition of the neointima, employing its conductivity and permittivity data. The bioimpedance model was validated against a finite element analysis (FEA using COMSOL Multiphysics software. A satisfactory correlation between the analytical model and FEA simulation was achieved in most cases, detecting some deviations introduced by the thin “double layer” that separates the neointima and the blood. It is hereby shown how to apply conformal transformations to obtain bioimpedance electrical models for stack-layered tissues over coplanar electrodes. Particularly, this can be applied to characterize the neointima in real-time. This technique is either suitable as a main mechanism for restenosis follow-up or it can be combined with proposed intelligent stents for blood pressure measurements to auto-calibrate the sensibility loss caused by the adherence of the tissue on the micro-electro-mechanical sensors (MEMSs.

  12. Intracranial Stent Implantation for Drug Resistant Atherosclerotic Stenosis: Results of 52 Cases

    International Nuclear Information System (INIS)

    Kim, Kuk Seon; Hwang, Dae Hyun; Ko, Young Hwan; Kang, Ik Won; Lee, Eil Seong; Han, You Mie; Kim, In Soo; Hur, Choon Woong

    2011-01-01

    We evaluated the usefulness of intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses. Between March 2004 and July 2007, we tried intracranial stent implantation in 49 patients with 52 lesions (anterior circulation 48 cases, posterior circulation 4 cases) who had an ischemic stroke with more than 50% of major cerebral artery stenosis. We classified the lesions by their location and morphology, analyzed the results in terms of the success rate, complication rate, and restenosis rate during the follow-up period. Intracranial stent implantation was performed successfully in 43 cases (82.7%). In eight of the nine cases, the stent implantation failure was due to the tortuosity of the target vessel. There was no major periprocedural complication. One patient showed cerebellar infarction after the procedure. Mean residual stenoses decreased from 70.2% to 13.0%. Four cases (9.3%) demonstrated in-stent restenoses and more than 50% during the mean and 25.3/month after the follow-up period. Success rate of intracranial stent implantation may improve on developing technique and more experience. Low rate of complication and restenosis suggest that we can consider intracranial stent implantation for treatment of drug resistant atherosclerotic stenoses.

  13. [Coronary stents: 30 years of medical progress].

    Science.gov (United States)

    Silvain, Johanne; Cayla, Guillaume; Collet, Jean-Philippe; Fargeot, Catherine; Montalescot, Gilles

    2014-03-01

    The history of interventional cardiology has been marked by several technologic revolutions since the late 1970s. The first key step was the use of inflatable balloon angioplasty as an alternative to CABG surgery for coronary revascularization, followed by intracoronary delivery of bare metal stent (BMS) and drug eluting stents (DES) to drastically reduce intracoronary restenosis observed with BMS. Improved stents platforms and polymers (absorbable or biocompatible) led to a dramatic reduction in the rate of late stent thrombosis. Self-expanding stents are now available to improve stent a position especially in acute myocardial infarction. The emergence of new fully bioabsorbable stents that can be combined with antiproliferative drugs is the ongoing revolution. A new generation of stents is continuously improving and likely to become the ideal stent for coronary revascularization in the near future. © 2014 médecine/sciences – Inserm.

  14. Wingspan stent system in the treatment of symptomatic intracranial atherosclerotic stenosis

    International Nuclear Information System (INIS)

    Li Tianxiao; Li Zhaoshuo; Wang Ziliang; Xue Jiangyu; Bai Weixing; Li Li; Zhai Shuiting; Feng Yingpu

    2010-01-01

    Objective: To assess the safety, feasibility, short- and mid-term efficacy of wingspan stent for treating patients with symptomatic intracranial artery stenosis. Methods: A total of 113 patients with severe symptomatic intracranial stenosis were enrolled and Gateway-wingspan stenting were performed on all patients. The technical success, the pre- and post-stenting stenosis, perioperative complications, clinical outcome and restenosis rates were recorded, and chi-square test was used for analysis of complication rate by comparing our results with the results of Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) study and NIH multi-center Wingspan stenting trial. Results: The technical success rate was 99.1% (112/ 113). The mean pre and post-stent stenoses were (80.7±9.3)% and (27.7±9.7)% (χ 2 =9.397, P<0.05). The total complication rate was 4.4% (5/113) during the follow-up (mean 14.5 months, range 1-28 months), and the frequency of' restenosis was 12.5% (5/40) at 6 months. The primary endpoint events, ischemic stroke, and lesion-related ischemic stroke were lower in our study (4.5%, 3.5%, 3.5%) compared with the results of WASID trial (21.1%, 20.4%, 15.0%, P<0.05). For those with poor outcome in the three high-risk sub-groups which were with more than 70% stenosis, or last event from the treatment was less than 17 days, or NIHSS was above 1, a better outcome was observed in our group (4.5%, 4.7% and 2.0% in our study, 19.0%, 17.0% and 19.6% in previous study, P<0.05). The medium-term efficacy in this group (4.5%) significantly improved compared with NIH study (14.0%, P< 0.05). Conclusions: Wingspan stenting for symptomatic intracranial arterial stenosis is with good safety, feasibility and low perioperative stroke rate and mortality. The incidence of primary endpoint events and the ischemic events are lower than those of medication group, and the efficacy of stenting is significantly better than medication even in high-risk population. (authors)

  15. Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

    Science.gov (United States)

    Gundogan, Buket; Tan, Aaron; Farhatnia, Yasmin; Alavijeh, Mohammad S.; Cui, Zhanfeng; Seifalian, Alexander M.

    2014-01-01

    Percutaneous coronary intervention (PCI) is one of the most commonly performed invasive medical procedures in medicine today. Since the first coronary balloon angioplasty in 1977, interventional cardiology has seen a wide array of developments in PCI. Bare metal stents (BMS) were soon superseded by the revolutionary drug-eluting stents (DES), which aimed to address the issue of restenosis found with BMS. However, evidence began to mount against DES, with late-stent thrombosis (ST) rates being higher than that of BMS. The bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the body. This temporary presence provides no triggers for ST, which is brought about by non-endothelialized stent struts and drug polymers remaining in vivo for extended periods of time. Likewise, nano-theranostics incorporated into a bioabsorbable stent of the future may provide an incredibly valuable single platform offering both therapeutic and diagnostic capabilities. Such a stent may allow delivery of therapeutic particles to specific sites thus keeping potential toxicity to a minimum, improved ease of tracking delivery in vivo by embedding imaging agents, controlled rate of therapy release and protection of the implanted therapy. Indeed, nanocarriers may allow an increased therapeutic index as well as offer novel post-stent implantation imaging and diagnostic methods for atherosclerosis, restenosis and thrombosis. It is envisioned that a nano-theranostic stent may well form the cornerstone of future stent designs in clinical practice. PMID:24672583

  16. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  17. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  18. Research progress of biodegradable stent in the application for benign luminal stenosis

    International Nuclear Information System (INIS)

    Zhu Yueqi; Cheng Yingsheng; Li Minghua

    2008-01-01

    Stent implantation plays an significant role in the interventional therapy, mainly with permanent stent, possessing many disadvantages such as restenosis and inflammatory hyperplasia and can thus hardly be used in children and nonmalignant stenosis. Biodegradable stent has theoretical capability to solve these problems and acquires a bright future. Nowadays, with the development of material industry and manufacture craft, biodegradable stent technique has turned up to be mature in last decades. Through the strict animal experiments and prophase of clinic application, satisfactory result has been acquired. We believe that bioabsorbable stent will be widely used in many benign diseases which would be a good supplement for permanent stent in the near future. (authors)

  19. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  20. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    International Nuclear Information System (INIS)

    Sahin, Sinan; Cimsit, Cagatay; Andac, Nurten; Baltacioglu, Feyyaz; Tuglular, Serhan; Akoglu, Emel

    2006-01-01

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions

  1. Renal artery stenting in solitary functioning kidneys: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Sinan [Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Hospital, Department of Radiology, Istanbul (Turkey)]. E-mail: sinan.sahin@e-kolay.net; Cimsit, Cagatay [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Andac, Nurten [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Baltacioglu, Feyyaz [Marmara University, School of Medicine, Department of Radiology, Istanbul (Turkey); Tuglular, Serhan [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey); Akoglu, Emel [Marmara University, School of Medicine, Department of Nephrology, Istanbul (Turkey)

    2006-01-15

    Objective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions.

  2. Progress in the study of drug-eluting intra-stent thrombosis

    International Nuclear Information System (INIS)

    Guo Zhifu; Zheng Xing; Qin Yongwen

    2007-01-01

    Durg-eluting stent has been regarded as the milestone in the history of PCI for their efficiency in the prevention of coronary arterial restenosis after percutaneous coronary intervention. But unfortunately intra-stent thrombosis continues to be a serious complication of contemporary DES use. The incidence of drug-eluting stents thrombosis is at least not lower than that of bare metal stents at present. The clinical consequences of stent thrombosis are frequently catastrophic, including death in 40% to 50% of the cases or major myocardial infarction in 60% to 70%. Premature discontinuation of standard antiplatelet therapy is by far the most important predictor of stent thrombosis with DES and other predictors included renal failure, diabetes, bifurcation lesions, multiple lesions or multivessel disease, long stents, female, advanced age, stent underexpansion and residual stenosis etc. The delayed endothelialization may be the underling mechanism of DES thrombosis. (authors)

  3. Complication rate in unprotected carotid artery stenting with closed-cell stents

    International Nuclear Information System (INIS)

    Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert

    2010-01-01

    The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)

  4. Biodegradable stents made of pure Mg and AZ91 alloy through SPS sintering

    OpenAIRE

    de Oliveira Botelho, Pedro Augusto

    2015-01-01

    The implantation of stents is an effective procedure to unblock the arteries of patients with serious heart problems. Traditionally, stents are made of inert materials such as stainless steel and titanium alloys. It has been shown that the traditional stents can cause restenosis or thrombosis. In recent years the proposal of biodegradable stents is attracting the interest of the industry and the research, since the stent is mechanically needed only in the first year, eliminating the problems ...

  5. Management of embedded metallic stents used in the treatment of grades III and IV subglottic, and upper tracheal stenosis in adults.

    Science.gov (United States)

    Sendi, Khalil; Al-Khatib, Talal; Ahmed, Duha G; Tonkul, Al-Baraa

    2014-11-01

    The aim of this study was to evaluate the post-operative complications of using balloon-expandable metallic stents in treatment of benign, major subglottic and tracheal stenosis in adult patients whom conventional therapy has failed and to demonstrate how to deal with these complications in the long run. A retrospective review of five cases; adlut patiets with benign, major subglottic and upper tracheal stenosis whom were treated with balloon expandable metallic stents at King Abdulaziz University Hospital, in the years between 2008 and 2013. Granulation tissue formed in five of the four cases and restenosis occurred. Other complications encountered were stent infection and dislodgment. The complications were managed by removing the stents surgically via a laryngofissure incision and required the placement of a Montgomery T-tube. Managing the restenosis due to granulation tissue formation around the metallic stents is best achieved by removing the embedded metallic stents surgically via open technique and then by placement of a Montgomery T-tube as a bridging option to successful decannulation. Open surgical procedures remain the mainstay treatment for advanced airway stenosis.

  6. The Erasme Study: A Multicenter Study on the Safety and Technical Results of the Palmaz Stent Used for the Treatment of Atherosclerotic Ostial Renal Artery Stenosis

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Goffette, Pierre P.; Henry, Michel; Mali, Willem P.T.M.; Melki, Jean-Pierre; Moss, Jon G.; Rabbia, Claudio; Therasse, Eric; Thomson, Kenneth R.; Thurnher, Siegfried; Vignali, Claudio

    1999-01-01

    Purpose: To assess, in a multicenter setting, safety, technical results, and restenosis rate of the Palmaz stent for treatment of atherosclerotic ostial renal artery stenosis. Methods: Ten centers enrolled 106 patients (120 treated renal artery stenoses) in the study. Patient selection was based on unsuccessful percutaneous transluminal renal angioplasty (residual stenosis ≥ 20%) performed for treatment of ostial stenosis ≥ 50%, in patients with hypertension and/or impaired renal function. Safety was assessed by means of the complication rate, and technical results by the number of successful stent placements and occurrence of restenosis (>50%) at intraarterial angiographic follow-up. Results: Stent placement was successful (n = 112) or partially successful (n = 5) in 117 (98%) arteries. Complications occurred in 19 procedures; seven were of serious clinical significance. Angiographic follow-up was performed in 89 of 117 (76%) cases, at a mean of 8 months (range 2.5-18 months). Fifteen stents (16.9%) showed restenosis (at a mean of 8.5 months), of which 10 were successfully redilated. Conclusion: Renal artery stenting has a high technical success rate, a complication rate comparable to percutaneous transluminal renal angioplasty, and a low rate of restenosis at 8 months angiographic follow-up

  7. Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis

    International Nuclear Information System (INIS)

    Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun

    2006-01-01

    Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)

  8. Treatment of 9 cases of pulmonary atelectasis caused by endobronchial tuberculosis with intraluminal stent implantation

    International Nuclear Information System (INIS)

    Ji Hongjiang; Li Qiang; Liu Zhongling; Bai Chong; Yao Xiaopeng; Zhao Lijun; Xu Hao; Dong Yuchao; Huang Haidong; Wang Qin

    2007-01-01

    Objective: To evaluate the effect and safety of intraluminal stent implantation in the treatment of complete airway obstruction with unilateral pulmonary atelectasis caused by endobronchial tuberculosis (EBTB). Methods: 9 cases of pulmonary atelectasis caused by EBTB were treated with high- frequency electricity/microwave, balloon dilation and endobronchial stent implantation. At the time of 1 week and 4-6 months after stenting ,the diameters of stenotic segment were measured. Results: All 9 cases with atelectasis of EBTB showed complete re-expansion within 3 days after the stent implantation. The mean diameter of the stenotic segments of 9 EBTB patients increased to 9.17 ± 1.24 mm at 7th day after stent implantation; 3 of 9 EBTB patients occured mild restenosis after implantation of tracheobronchial stents. However, combination therapy of cryotherapy and balloon dilation can effectively prevent the aggravation of restenosis. Conclusion: Comparing with traditional surgical treatment, the intraluminal stent implantation for atelectasis caused by EBTB is a new, effective, safe and microtraumatic method with reliable preservation of pulmonary function. (authors)

  9. In vitro stent lumen visualisation of various common and newly developed femoral artery stents using MR angiography at 1.5 and 3 tesla.

    Science.gov (United States)

    Syha, R; Ketelsen, D; Kaempf, M; Mangold, S; Sixt, S; Zeller, T; Springer, F; Schick, F; Claussen, C D; Brechtel, K

    2013-02-01

    To evaluate stent lumen assessment of various commonly used and newly developed stents for the superficial femoral artery (SFA) using MR angiography (MRA) at 1.5 and 3 T. Eleven nitinol stents and one cobalt-chromium stent were compared regarding stent lumen visualisation using a common three-dimensional MRA sequence. Maximum visible stent lumen width and contrast ratio were analysed in three representative slices for each stent type. A scoring system for lumen visualisation was applied. Nitinol stents showed significantly better performance than the cobalt chromium stent (P stent lumen ranged between 43.4 and 95.5 %, contrast ratio between 7.2 and 110.6 %. Regarding both field strengths, seven of the nitinol stents were classified as "suitable". Three nitinol stents were "limited", and one nitinol stent and the cobalt chromium stent were "not suitable". Intraluminal loss of signal and artefacts of most of the SFA stents do not markedly limit assessment of stent lumen by MRA at 1.5 and 3 T. MRA can thus be considered a valid technique for detection of relevant in-stent restenosis. Applied field strength does not strongly influence stent lumen assessment in general, but proper choice of field strength might be helpful.

  10. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    Science.gov (United States)

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  11. Short-term outcome after stenting versus endarterectomy for symptomatic carotid stenosis: a preplanned meta-analysis of individual patient data.

    Science.gov (United States)

    Bonati, Leo H; Dobson, Joanna; Algra, Ale; Branchereau, Alain; Chatellier, Gilles; Fraedrich, Gustav; Mali, Willem P; Zeumer, Hermann; Brown, Martin M; Mas, Jean-Louis; Ringleb, Peter A

    2010-09-25

    Results from randomised controlled trials have shown a higher short-term risk of stroke associated with carotid stenting than with carotid endarterectomy for the treatment of symptomatic carotid stenosis. However, these trials were underpowered for investigation of whether carotid artery stenting might be a safe alternative to endarterectomy in specific patient subgroups. We therefore did a preplanned meta-analysis of individual patient data from three randomised controlled trials. Data from all 3433 patients with symptomatic carotid stenosis who were randomly assigned and analysed in the Endarterectomy versus Angioplasty in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S) trial, the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) trial, and the International Carotid Stenting Study (ICSS) were pooled and analysed with fixed-effect binomial regression models adjusted for source trial. The primary outcome event was any stroke or death. The intention-to-treat (ITT) analysis included all patients and outcome events occurring between randomisation and 120 days thereafter. The per-protocol (PP) analysis was restricted to patients receiving the allocated treatment and events occurring within 30 days after treatment. In the first 120 days after randomisation (ITT analysis), any stroke or death occurred significantly more often in the carotid stenting group (153 [8·9%] of 1725) than in the carotid endarterectomy group (99 [5·8%] of 1708, risk ratio [RR] 1·53, [95% CI 1·20-1·95], p=0·0006; absolute risk difference 3·2 [1·4-4·9]). Of all subgroup variables assessed, only age significantly modified the treatment effect: in patients younger than 70 years (median age), the estimated 120-day risk of stroke or death was 50 (5·8%) of 869 patients in the carotid stenting group and 48 (5·7%) of 843 in the carotid endarterectomy group (RR 1·00 [0·68-1·47]); in patients 70 years or older, the estimated risk with carotid stenting was twice that

  12. A randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results.

    Science.gov (United States)

    López-Mínguez, José R; Nogales-Asensio, Juan M; Doncel-Vecino, Luis J; Merchán-Herrera, Antonio; Pomar-Domingo, Francisco; Martínez-Romero, Pedro; Fernández-Díaz, José A; Valdesuso-Aguilar, Raúl; Moreu-Burgos, José; Díaz-Fernández, José

    2014-07-01

    Up to 25% of patients who undergo a percutaneous coronary intervention show some limitation in the use of drug-eluting stents. The aim of this study was to evaluate if titanium-nitride-oxide-coated stents could be a good alternative to everolimus-eluting stents in diabetic patients. A total of 173 diabetic patients with lesions at moderate risk of restenosis (exclusion criteria: diameter 28 mm in vessels < 3mm, chronic occlusion) were randomized to a titanium group (83 patients) or an everolimus group (90 patients). Baseline characteristics were well balanced; 28.3% of patients were insulin dependent. At 1 year, the incidence of major adverse cardiac events (death, nonfatal myocardial infarction, stroke, or repeat target vessel revascularization) was significantly higher in the titanium group than in the everolimus group (total, 14.5% vs 4.4%; P = .02; noninsulin-dependent subgroup, 9.7% vs 3.2%; P = .14; insulin-dependent subgroup, 28.6% vs 7.1%; P = .04). The incidence of death, nonfatal myocardial infarction, stroke, or any revascularization was 16.9% in the titanium group and 7.8% in the everolimus group (P = .06). Target lesion and vessel revascularizations occurred in 8.4% compared with 3.3% (P = .15) and in 13.3% compared with 3.3% (P = .01) in the titanium and everolimus groups, respectively. Angiographic follow-up at 9 months showed significantly less late lumen loss in the everolimus group (in-segment, 0.52 [standard deviation, 0.58) mm vs -0.05 [0.32] mm; in-stent, 0.76 [0.54] mm vs 0.13 [0.31] mm; P < .0001). The everolimus-eluting stent is superior to the titanium stent for clinical and angiographic end points in diabetic patients with lesions at moderate risk of restenosis. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  13. Agreement of duplex ultrasonography vs. computed tomography angiography for evaluation of native and in-stent SFA re-stenosis—Findings from a randomized controlled trial

    International Nuclear Information System (INIS)

    Langenberger, Herbert; Schillinger, Martin; Plank, Christina; Sabeti, Schila; Dick, Petra; Cejna, Manfred; Lammer, Johannes; Minar, Erich; Loewe, Christian

    2012-01-01

    Background: Multidetector CT angiography (CTA) is a non-invasive imaging technique for evaluation of peripheral vascular disease. CTA might be particularly useful for assessment of intermediate- and long-term morphological outcome after endovascular treatment. Validation of CTA vs. the current imaging standard, colour Doppler ultrasonography (CDUS), for quantification of native and in-stent re-stenosis in the superficial femoral artery (SFA) is required. Methods: Seventy randomized patients who underwent stent implantation (n = 47) or balloon angioplasty (n = 23) underwent 6-month follow-up with CDUS and CTA. CTA was compared with CDUS in both sub-groups of patients in terms of binary re-stenosis (>50% lumen narrowing) and re-occlusion. Agreement between CTA and CDUS was assessed using Kappa (κ) statistics with 95% confidence intervals, and correlation coefficients. Results: Binary re-stenosis was detected in 16/70 (22.9%) patients by CTA and 17/70 (24.3%) patients by CDUS (κ = 0.88, 95% CI: 0.80–0.96). Re-stenosis rates after balloon angioplasty were 39.1% (9/23) on CTA and CDUS (κ = 0.82, 95% CI: 0.66–0.98), and after stent implantation 14.9% (7/47) on CTA and 17.0% (8/47) on CDUS (κ = 0.92, 95% CI: 0.84–1.00). Re-occlusions were detected in 3/70 (4.3%) patients by both CTA and CDUS (κ = 0.65; 95% CI 0.54–0.76). Significant correlations (r = 0.85, p < 0.001) were noted between degree of re-stenosis on CTA and peak velocity ratio on CDUS. The correlation coefficient was higher in patients after balloon angioplasty (r = 0.94, p < 0.001) than in patients after stent implantation (r = 0.71, p < 0.001). Conclusion: CTA and CDUS show excellent agreement for evaluation of native and in-stent re-stenosis after endovascular treatment of SFA obstructions. CTA is an appropriate non-invasive imaging modality for follow-up after endovascular therapy

  14. Renal artery stent angioplasty for renovascular hypertension

    International Nuclear Information System (INIS)

    Li Gang; Li Haiqing; Wang Lin

    2005-01-01

    Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)

  15. Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)

    Science.gov (United States)

    de Jaegere, P; Mudra, H; Figulla, H; Almagor, Y; Doucet, S; Penn, I; Colombo, A; Hamm, C; Bartorelli, A; Rothman, M; Nobuyoshi, M; Yamaguchi, T; Voudris, V; DiMario, C; Makovski, S; Hausmann, D; Rowe, S; Rabinovich, S; Sunamura, M; van Es, G A

    1998-08-01

    A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. The study was designed to be multicentred, prospective, and observational. One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8

  16. Stent-assisted angioplasty for intracranial atherosclerosis

    International Nuclear Information System (INIS)

    Nakahara, Toshinori; Sakamoto, Shigeyuki; Hamasaki, Osamu; Sakoda, Katsuaki

    2002-01-01

    We report on two patients with intracranial atherosclerosis of the carotid artery or vertebral artery treated with stent-assisted angioplasty. Both patients have severe intracranial atherosclerosis (>70%) with refractory symptoms despite optimal medical treatment. In both patients, a coronary balloon-expandable stent was successfully placed using a protective balloon technique without procedural complications. The patients were asymptomatic and neurologically intact at a mean clinical follow-up of 13 months. Follow-up angiograms did not show restenosis 3 or 4 months after procedure, respectively. Stent-assisted angioplasty for intracranial atherosclerosis in the elective patient has proven effective, with an acceptable low rate of morbidity and mortality. (orig.)

  17. Neointimal responses 3 months after 32P β-emitting stent placement

    International Nuclear Information System (INIS)

    Farb, Andrew; Tang, Anita L.; Shroff, Sweta; Sweet, William; Virmani, Renu

    2000-01-01

    Purpose: Studies have shown a potential benefit of brachytherapy in preventing restenosis. However, the effects of intravascular radiation on arterial healing have not been well-established. The purpose of this study was to explore the histologic changes following placement of β-emitting radioactive stents in arteries focusing on intimal responses and endothelialization. Methods and Materials: 3.0-mm β-emitting 32 P stents (6-μCi and 24-μCi) were placed in rabbit iliac arteries with nonradioactive stents serving as controls. Animals were euthanized at 3 months and histologic assessment, morphometry, and analysis of endothelialization were performed. Results: The lumen areas of 24-μCi stents (4.24 ± 0.22 mm 2 , p 2 , p 2 ). The mean lumen percent stenosis was 11.4 ± 3.0% in the 24-μCi stents (p 32 P β-emitting stents reduce neointimal growth, but healing is incomplete with poor endothelialization at 3 months. Longer-term studies with complete arterial healing are needed to determine whether there is sustained neointimal inhibition by stent-delivered brachytherapy

  18. Treatment of tracheobronchial stenosis with a self-expandable metallic stents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeon, Seok Chol; Choi, Chul Seung; Choi, Yo Won; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1994-07-15

    We analysed the role of modified Gianturco self-expandable stents in the treatment of tracheobronchial stenosis in 13 patients. We inserted modified Gianturco self-expandable stents under the fluoroscopic and bronchoscopic guidance. There were stenosis in the trachea(n=2), the right main bronchus(n=2), and the left main bronchus(n=9). The causes of the stenosis were endobronchial tuberculosis(n=10), intubation granuloma(n=1), restenosis after surgical reconstruction(n=2). Dyspnea or wheezing was improved within 1 or 2 days following the procedure. There were 32% and 22% respective increase in average FEV1 and FVC. Lung perfusion scan showed 9.6% increase of perfusion in the involved lung. No complications related to the procedure were encountered. During follow-up period of up to 31 months, 2 patients showed tracheal or bronchial restenosis, at 3 and 6 months, retrospectively. There was a distal migration of the stents in one case. During the follow up period after stent insertion, improvement of the obstructive changes and dyspnea persisted in 10 out of 13 patients. The modified Gianturco self-expandable metallic stents may be a good choice for the treatment of tracheobronchial stenosis, either as a primary treatment, or when the reconstruction failed.

  19. Safety and efficacy of rotational atherectomy for the treatment of undilatable underexpanded stents implanted in calcific lesions.

    Science.gov (United States)

    Ferri, Luca A; Jabbour, Richard J; Giannini, Francesco; Benincasa, Susanna; Ancona, Marco; Regazzoli, Damiano; Mangieri, Antonio; Montorfano, Matteo; Colombo, Antonio; Latib, Azeem

    2017-08-01

    Coronary stent underexpansion is a known risk factor for in-stent restenosis and stent thrombosis. There are limited options once noncompliant balloons have failed to achieve optimal stent expansion. Excimer Laser Coronary Angioplasty with contrast medium injection is one possibility, but not readily available. Rotational atherectomy is an alternative, and has been described in case reports, but concerns exist regarding safety. All consecutive patients undergoing rotational atherectomy for symptomatic in-stent restenosis due to stent underexpansion resistant to noncompliant balloon postdilatation between January 2005 and December 2015 were analysed. A total of 16 patients underwent treatment during the study period and the procedure was successful in 14 cases (87.5%). The mean postprocedural minimal lumen diameter increased by 2.3 ± 0.8 mm and percentage diameter stenosis decreased from 82.17% ± 17.2% to 11.9% ± 9.1%. Intraprocedural complications occurred in two patients (burr entrapment successfully managed percutaneously and periprocedural myocardial infarction). At 1-year follow-up, the incidence of target lesion revascularisation was 13.3% (2 out of 15 patients), and one patient died from noncardiac death. In this small series of underexpanded stents, rotational atherectomy was an effective treatment for resistant stent underexpansion with acceptable outcomes. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials.

    Science.gov (United States)

    Kheiri, Babikir; Osman, Mohammed; Abdalla, Ahmed; Ahmed, Sahar; Bachuwa, Ghassan; Hassan, Mustafa

    2018-05-11

    The use of drug-eluting stents (DES) vs bare-metal stents (BMS) in saphenous vein graft (SVG) lesions remains controversial. We conducted a meta-analysis of all randomized clinical trials comparing the outcomes of DES with BMS in SVG percutaneous coronary interventions. A search of PubMed, Embase, the Cochrane Register of Controlled Trials, and Clinicaltrials.gov was performed for all randomized clinical trials. We evaluated the short- and long-term clinical outcomes of the following: all-cause mortality, major adverse cardiovascular events (MACE), definite/probable stent thrombosis, target lesion revascularization (TLR), and target-vessel revascularization (TVR). From a total of 1582 patients in 6 randomized clinical trials, 797 had DES and 785 had BMS. Patients with DES had lower short-term MACE, TLR, and TVR in comparison with BMS (odds ratio [OR]: 0.56, 95% confidence interval [CI]: 0.35-0.91, P = 0.02; OR: 0.43, 95% CI: 0.19-0.99, P = 0.05; and OR: 0.45, 95% CI: 0.22-0.95, P = 0.04, respectively). However, there were no different outcomes for all-cause mortality (P = 0.63) or stent thrombosis (P = 0.21). With long-term follow-up, there were no significant reductions of MACE (P = 0.20), TLR (P = 0.57), TVR (P = 0.07), all-cause mortality (P = 0.29), and stent thrombosis (P = 0.76). The use of DES in SVG lesions was associated with lower short-term MACE, TLR, and TVR in comparison with BMS. However, there were no significant differences with long-term follow-up. © 2018 Wiley Periodicals, Inc.

  1. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  2. First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial.

    Science.gov (United States)

    von Birgelen, Clemens; Asano, Taku; Amoroso, Giovanni; Aminian, Adel; Brugaletta, Salvatore; Vrolix, Mathias; Hernandez-Antolín, Rosana; van de Harst, Pim; Iñiguez, Andres; Janssens, Luc; Smits, Pieter C; Wykrzykowska, Joanna J; Ribeiro, Vasco Gama; Pereira, Hélder; da Silva, Pedro Canas; Piek, Jan J; Onuma, Yoshinobu; Serruys, Patrick W; Sabaté, Manel

    2018-04-20

    A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.

  3. Antirestenotic Effects of a Novel Polymer-Coated D-24851 Eluting Stent. Experimental Data in a Rabbit Iliac Artery Model

    International Nuclear Information System (INIS)

    Lysitsas, Dimitrios N.; Katsouras, Christos S.; Papakostas, John C.; Toumpoulis, Ioannis K.; Angelidis, Charalampos; Bozidis, Petros; Thomas, Christopher G.; Seferiadis, Konstantin; Psychoyios, Nikolaos; Frillingos, Stathis; Pavlidis, Nikolaos; Marinos, Euaggelos; Khaldi, Lubna; Sideris, Dimitris A.; Michalis, Lampros K.

    2007-01-01

    Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (dl-lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 ± 0.0025 μM (31 ± 1 μg; low dose; n = 7), 0.55 ± 0.02 μM (216 ± 8 μg; high dose; n = 6), and 4.55 ± 0.1 μM (1774 ± 39 μg; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained

  4. Stented Vessels: A Challenge for Histological Preparation and Microscopy

    Directory of Open Access Journals (Sweden)

    Andrea Nolte

    2013-06-01

    Full Text Available Objective: The first procedure to treat blocked coronary arteries was coronary artery bypass graft surgery. In 1977, Andreas Gruntzig introduced percutaneous transluminal coronary angioplasty (PTCA. Today, several stent systems exist ranging from bare metal stents to various drug-eluting stents. Unfortunately, our understanding of the arterial reaction to stent implantation is incomplete – primarily due to technical limitations in the histological study of stented vascular tissue. Methods: In our study, we examined different histological preparation methods based on the embedding material methacrylate. The procedure of embedding and sectioning stented porcine arteries was optimized for the specific requirements, like histochemistry, immunohistochemistry or pre-stained fluorescence. Furthermore, we used a microscopical technique described as fluorescence intensity decay shape analysis microscopy (FIDSAM to eliminate auto-fluorescence from fluorescently labeled tissue. Results: The sections were suitable for histochemical and immunohistochemical staining. Additionally, pre-labeled fluorescence in the porcine tissue was not lost by the embedding process. The evaluation of arterial cross sections with FIDSAM technology gave new, very important insights into the examination possibilities of fluorescently labeled tissue. Conclusions: Future studies of the vascular response to a variety of new stent materials will provide important clues to the pathogenesis resulting in restenosis and occlusion of stents. [J Interdiscipl Histopathol 2013; 1(3.000: 104-112

  5. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  6. Comparison of the sirolimus-eluting versus paclitaxel-eluting coronary stent in patients with diabetes mellitus: the diabetes and drug-eluting stent (DiabeDES) randomized angiography trial

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette Okkels; Galloe, Anders Michael

    2008-01-01

    group (0.23 +/- 0.54 vs 0.44 +/- 0.52 mm, p = 0.025). Angiographic in-segment restenosis at 8-month follow-up, a secondary end point, was present in 16 patients (Cypher, n = 6; Taxus, n = 10; p = 0.24). Target lesion revascularization was performed in 5 patients (6.5%) and 9 patients (11.......8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite...

  7. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    Science.gov (United States)

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion

  8. Intravascular brachytherapy in prevention of the secondary restenosis angioplasty transluminal coronaries

    International Nuclear Information System (INIS)

    Mejia, S.

    2001-01-01

    The radiotherapy coronary intravascular has demonstrated in a convincing way in clinical and experimental studies that produces a favorable decrease of the restenosis process. There is enough evidence to define this technique as the main current therapeutic option in the handling of the reestenosis intra stent. Accumulated experience exists of up to 3 years in patient's treaties with radiation gamma and multiple studies in several centers that demonstrate similar benefits with issuing beta. The present articulates it revises a series of radiotherapy systems and makes a setting a day on the employment of the brachytherapy intravascular in cardiologic patient

  9. Factors that affect mass transport from drug eluting stents into the artery wall

    Directory of Open Access Journals (Sweden)

    Walsh Michael T

    2010-03-01

    Full Text Available Abstract Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.

  10. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  11. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention.

    Science.gov (United States)

    Baschet, Louise; Bourguignon, Sandrine; Marque, Sébastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117 762 patient-years with 76 randomised trials. The main effectiveness criterion was major cardiac event-free survival. Effectiveness and costs were modelled over a 5-year horizon using a three-state Markov model. Incremental cost-effectiveness ratios and a cost-effectiveness acceptability curve were calculated for a range of thresholds for willingness to pay per year without major cardiac event gain. Deterministic and probabilistic sensitivity analyses were performed. Base case results demonstrated that DES are dominant over BMS, with an increase in event-free survival and a cost-reduction of €184, primarily due to a diminution of second revascularisations, and an absence of myocardial infarction and stent thrombosis. These results are robust for uncertainty on one-way deterministic and probabilistic sensitivity analyses. Using a cost-effectiveness threshold of €7000 per major cardiac event-free year gained, DES has a >95% probability of being cost-effective versus BMS. Following DES price decrease, new-generation DES development and taking into account recent meta-analyses results, the DES can now be considered cost-effective regardless of selective indication in France, according to European recommendations.

  12. Stenting for peripheral artery disease of the lower extremities: an evidence-based analysis.

    Science.gov (United States)

    2010-01-01

    -popliteal, crural and iliac artery stenosis or occlusion), does primary stenting provide immediate success compared to PTA?In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion), is primary stenting associated with less complications compared to PTA?In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion), does primary stenting compared to PTA reduce the rate of re-intervention?In individuals with PAD of the lower extremities (superficial femoral artery, infra-popliteal, crural and iliac artery stenosis or occlusion) is primary stenting more effective than PTA in improving clinical and hemodynamic success?Are drug eluting stents more effective than bare stents in improving patency, reducing rates of re-interventions or complications? A literature search was performed on February 2, 2010 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, OVID EMBASE, the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA). Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any additional relevant studies not identified through the search. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. English language full-reports from 1950 to January Week 3, 2010Comparative randomized controlled trials (RCTs), systematic reviews and meta-analyses of RCTsProven diagnosis of PAD of the lower extremities in all patients.Adult patients at least 18 years of age.Stent as at least one treatment arm.Patency, re-stenosis, re-intervention, technical success, hemodynamic (ABI) and clinical improvement and complications as at least an outcome. Non-randomized studiesObservational studies (cohort or retrospective studies) and

  13. The study of drug eluting biodegradable intravascular stent with antiproliferation agent-paclitaxel in preventing vascular restenosis

    International Nuclear Information System (INIS)

    Xiao Yueyong; Zhang Jinshan; Cui Fuzhai; Meng Bo

    2004-01-01

    Objective: To define the effect of drug eluting BIS with antiproliferation agent-paclitaxel in preventing vascular restenosis. Methods: Bare BIS and drug BIS with 60 μg paclitaxel were prepared. Both types of the BIS were implanted into the infrarenal restenosis aortas in canine models, and the animals were euthanized 6 weeks after implantation for histopathological, morphometric and immunohistochemical assessment. Results: The mean lumen area of bare BIS group was (77 586.5 ± 66.0) μm 2 , and lumen of paclitaxel eluting BIS group was (113 435.9 ±71.0) μm 2 . The mean neointima area of bare BIS group was (24 803 ± 56) μm 2 , and paclitaxel eluting BIS group was (12 931 ± 63) μm 2 . The PCNA-positive ratio was (38 ± 15)% in bare BIS group and (11 ± 0.31)% in paclitaxel eluting BIS group. The statistically significant difference between the two groups were noted (P<0.01). Conclusion: BIS as a vehicle of loading and releasing drugs could significantly inhibit the VSMC and neointimal hyperplasia with antiproliferation agent-paclitaxel. BIS is a promising and new strategy in preventing the restenosis

  14. Introduction of a high-throughput double-stent animal model for the evaluation of biodegradable vascular stents.

    Science.gov (United States)

    Borinski, Mauricio; Flege, Christian; Schreiber, Fabian; Krott, Nicole; Gries, Thomas; Liehn, Elisa; Blindt, Rüdiger; Marx, Nikolaus; Vogt, Felix

    2012-11-01

    Current stent system efficacy for the treatment of coronary artery disease is hampered by in-stent restenosis (ISR) rates of up to 20% in certain high-risk settings and by the risk of stent thrombosis, which is characterized by a high mortality rate. In theory, biodegradable vascular devices exhibit crucial advantages. Most absorbable implant materials are based on poly-L-lactic acid (PLLA) owing to its mechanical properties; however, PLLA might induce an inflammatory reaction in the vessel wall. Evaluation of biodegradable implant efficacy includes a long-term examination of tissue response; therefore, a simple in vivo tool for thorough biocompatibility and biodegradation evaluation would facilitate future stent system development. Rats have been used for the study of in vivo degradation processes, and stent implantation into the abdominal aorta of rats is a proven model for stent evaluation. Here, we report the transformation of the porcine double-stent animal model into the high-throughput rat abdominal aorta model. As genetic manipulation of rats was introduced recently, this novel method presents a powerful tool for future in vivo biodegradable candidate stent biocompatibility and biodegradation characterization in a reliable simple model of coronary ISR. Copyright © 2012 Wiley Periodicals, Inc.

  15. An argument for the use of multiple segment stents in curved arteries.

    Science.gov (United States)

    Kasiri, Saeid; Kelly, Daniel J

    2011-08-01

    Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.

  16. Drug-eluting stents appear superior to bare metal stents for vein-graft PCI in vessels up to a stent diameter of 4 mm

    Directory of Open Access Journals (Sweden)

    Oliver P. Guttmann

    2016-05-01

    Full Text Available BackgroundResearch trials have shown improved short-term outcome with drug-eluting stents (DES over bare metal stents (BMS in saphenous vein graft (SVG percutaneous coronary intervention (PCI, primarily by reducing target vessel revascularization (TVR for in-stent restenosis. We compared the outcomes in patients undergoing SVG stent implantation treated with DES or BMS. In exploratory analyses we investigated the influence of stent generation and diameter.MethodsData were obtained from a prospective database of 657 patients who underwent PCI for SVG lesions between 2003 and 2011. A total of 344 patients had PCI with BMS and 313 with DES. Propensity scores were developed based on 15 observed baseline covariates in a logistic regression model with stent type as the dependent variable. The nearest-neighbour-matching algorithm with Greedy 5-1 Digit Matching was used to produce two patient cohorts of 313 patients each. We assessed major adverse cardiac events (MACE out to a median of 3.3 years (interquartile range: 2.1-4.1. MACE was defined as all-cause mortality, myocardial infarction (MI, TVR and stroke.ResultsThere was a significant difference in MACE between the two groups in favour of DES (17.9% DES vs. 31.2% BMS group; p = 0.0017 over the 5-year follow-up period. MACE was driven by increased TVR in the BMS group. There was no difference in death, MI or stroke. Adjusted Cox analysis confirmed a decreased risk of MACE for DES compared with BMS 0.75 (95% confidence interval (CI 0.52-0.94, with no difference in the hazard of all-cause mortality (hazard ratio: 1.08; 95% CI: 0.77-1.68. However, when looking at stent diameters greater than 4 mm, no difference was seen in MACE rates between BMS and DES.ConclusionsOverall in our cohort of patients who had PCI for SVG disease, DES use resulted in lower MACE rates compared with BMS over a 5-year follow-up period; however, for stent diameters over 4 mm no difference in MACE rates was seen.

  17. Clinical observation of intraluminal stent angioplasty in the treatment of renal arterial stenoses

    International Nuclear Information System (INIS)

    Lu Yanwen; Zhang Jian; Huang Xianglong

    2002-01-01

    Objective: To evaluate the clinical application of intraluminal stent angioplasty (PTRAS) in the treatment of renal arterial stenoses. Methods: A retrospective study was done in 28 patients with renal arterial stenoses. Primary renal artery stenting was performed in 28 consecutive patients (36 renal arteries). Blood pressure, serum creating, the number of anti-hypertensive medications were recorded at 1, 6, 12 month post stent angioplasty respectively. Arterial angiography was also taken 1 year later to evaluate the incidence of restenosis. Results: Technical success rate was 100% achieving in all patients without serious complications. Primary successful patently rate reached 82% (renal artery 86%), secondary successful rate was 89% (renal artery 90%). Systolic and diastolic blood pressure were reduced significantly (P<0.01) at 1,6,12 month after stent angioplasty comparing with baseline and clinical improvement (cured + improved) of hypertension reached 100%, 92.9%, 89.3% respectively. There were no significant differences between serum creatine level and the number of anti-hypertensive medications before and after stent angioplasty. One year later, 14.3% of all patients showed improvement of renal function, 64.3% remained in stabilization and 21.4% fell into deterioration. Angiographic restenosis was found in 3 cases one year after stent angioplasty. Complications included 1 hematoma at puncture site and 3 transient azotaemia. Conclusions: PTRAS can be performed safely with high technical success and beneficial to the majority of patients with hypertension or renal insufficiency and therefore it should be the first choice in treating renal arterial stenoses

  18. The relationship between the high-density lipoprotein (HDL)-associated sphingosine-1-phosphate (S1P) and coronary in-stent restenosis.

    Science.gov (United States)

    Jing, Xiao-Dong; Wei, Xiao-Ming; Deng, Song-Bai; Du, Jian-Lin; Liu, Ya-Jie; She, Qiang

    2015-06-15

    High-density lipoprotein (HDL)-associated sphingosine-1-phosphate (S1P) contributed to several beneficial effects in the cardiovascular system. We explored the relationship between the HDL-S1P concentrations and coronary in-stent restenosis (ISR). Fifty consecutive patients with ISR and 50 normal control subjects were included. The serum S1P, HDL-S1P and clinical data were collected to explore the relationships between these parameters and ISR. The patients with ISR had significantly lower concentrations of serum S1P (96.10 ± 26.33 vs. 113.40 ± 32.72; P = 0.004) and HDL-S1P (32.81 ± 10.02 vs. 42.72 ± 11.75; P S1P: Quartile 1 (18.63-28.51 ng/ml), Quartile 2 (28.62-37.28 ng/ml), Quartile 3 (37.35-45.27 ng/ml), and Quartile 4 (45.59-79.36 ng/ml). The rates of ISR were 84%, 48%, 40% and 28%, respectively. The patients in Quartile 1 exhibited significantly higher rates of ISR compared with the other groups (P = 0.001). A multivariate stepwise logistic regression analysis indicated that HDL-S1P (OR = 0.846, 95% CI = 0.767-0.932, P = 0.001) was an independent predictor of ISR. An ROC analysis indicated that HDL-S1P = 30.37 ng/ml and had a 90% sensitivity and a 52% specificity in predicting ISR. HDL-S1P is an independent predictor of ISR, and patients with higher concentrations of HDL-S1P have a low risk of ISR. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Local perivascular delivery of anti-restenotic agents from a drug-eluting poly(ε-caprolactone) stent cuff

    NARCIS (Netherlands)

    Pires, N.M.M.; Hoeven, B.L. van der; Vries, M.R. de; Havekes, L.M.; Vlijmen, B.J. van; Hennink, W.E.; Quax, P.H.A.; Jukema, J.W.

    2005-01-01

    The introduction of drug-eluting stents (DES) to prevent in-stent restenosis is one of the major advances in interventional cardiology. Currently many types of DES are under evaluation for effectiveness and safety, a time-consuming and difficult procedure in humans. An animal model that allows rapid

  20. Assessment of the safety and performance of the STENTYS self-expanding coronary stent in acute myocardial infarction: Results from the APPOSITION I study

    NARCIS (Netherlands)

    G. Amoroso (Giovanni); R.J.M. van Geuns (Robert Jan); C.M. Spaulding (Christian); S. Manzo-Silberman (Stephane); K. Hauptmann (Karl); R. Spaargaren (René); H.M. Garcia-Garcia (Hector); P.W.J.C. Serruys (Patrick); S. Verheye (Stefan)

    2011-01-01

    textabstractAims: In the setting of ST-elevation myocardial infarction (STEMI), epicardial vasoconstriction and throm- bus load may lead to stent undersizing and malapposition after primary percutaneous coronary intervention (PPCI), which can both be responsible for stent thrombosis or restenosis.

  1. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  2. Drug-eluting stents: from bench-top to clinical research

    NARCIS (Netherlands)

    Basalus, Mounir Welson Zakhary

    2013-01-01

    The development of drug-eluting stents (DES) has improved the invasive treatment of obstructive coronary artery disease by reducing both, restenosis rate and need for reinterventions. This success resulted in a widespread utilization of DES in clinical practice and entailed many clinical research

  3. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  4. Arterial stenting with self-expandable and balloon-expandable endoprostheses

    NARCIS (Netherlands)

    W.J. van der Giessen (Wim); P.W.J.C. Serruys (Patrick); L.J. van Woerkens (L.); K.J. Beatt (Kevin); W.J. Visser (Willy); J.F. Jongkind; R.H. van Bremen (Robert); E. Ridderhof; H. van Loon (Heleen); L.K. Soei (Lou Kie); H.M.M. van Beusekom (Heleen); P.D. Verdouw (Pieter)

    1990-01-01

    textabstractCoronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several

  5. Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers.

    Science.gov (United States)

    Kan, Jing; Ge, Zhen; Zhang, Jun-Jie; Liu, Zhi-Zhong; Tian, Nai-Liang; Ye, Fei; Li, Sui-Ji; Qian, Xue-Song; Yang, Song; Chen, Meng-Xuan; Rab, Tanveer; Chen, Shao-Liang

    2016-06-13

    The present study aimed to analyze the incidence of SF and its correlation with clinical events after DES implantation and the outcome of re-intervention for symptomatic in-stent restenosis (ISR) induced by stent fracture (SF). SF is associated with a high rate of clinical events after the implantation of drug-eluting stents (DES). However, the chronological rate of SF and the effect of SF on clinical outcomes from a large patient population remain underreported. A total of 6,555 patients with 16482 DES in 10751 diseased vessels and surveillance angiography between November 2003 and January 2014 were prospectively studied. The primary endpoints included the incidence of SF, in-stent restenosis (ISR), target lesion revascularization (TLR), and definite stent thrombosis (ST) at the end of follow-up before and after propensity score matching. Clinical outcomes after TLR were also followed up. The SF rate was detected in 803 (12.3%) patients, 3,630 (22.0%) stents, and 1,852 (17.2%) diseased vessels. SF increased over time. SF was associated with higher unadjusted rates of ISR (42.1%), TLR (24.8%, n = 379), and definite ST (4.6%) compared with stents without fracture (10.7%, 6.6%, and 1.03%, all p stents after reintervention, and 6 (7.5%) stents required repeat TLR. SF is more frequently observed after DES implantation. TLR was required in almost one-fourth of fractured stents. Increased events in the SF group did not translate into a difference in mortality compared with the non-SF group. Reintervention was associated with acceptable clinical results. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. The role of solifenacin, as monotherapy or combination with tamsulosin in ureteral stent-related symptoms: a systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Jue; Zhang, Xiaobei; Zhang, Tiande; Mu, Jianjun; Bai, Bing; Lei, Yi

    2017-11-01

    Ureteral stenting is associated with various morbidity and reduced quality of life. We systematically evaluated the efficacy and safety of solifenacin as monotherapy, or combined therapy with tamsulosin versus control or tamsulosin monotherapy in stent-related symptoms (SRSs). Randomized controlled trials evaluating solifenacin or its combination with tamsulosin for the treatment of SRSs were identified via a comprehensive search of Pubmed, Embase, Ovid, The Cochrane Library and relevant sources up to February 2017. Ureteral stent symptom questionnaire (USSQ) and drug-related complications were pooled for meta-analysis. Mean difference and risk difference were calculated as appropriate for each outcome to determine the cumulative effect size. There were 10 studies involving 1786 participants finally eligible in the quantitative analysis. Solifenacin monotherapy significantly reduced the total score of USSQ [MD -14.90; 95% CI (-25.19, -4.60); P = 0.005], as well as indexes of urinary symptoms, body pain, general health, sexual performance, and hematuria (P = 0.02, P = 0.009, P = 0.004, P = 0.02, P = 0.02, respectively), but the differences were insignificant when compared with tamsulosin except improved sexual performance (P = 0.004). Combined therapy of solifenacin and tamsulosin showed no beneficial effects in all indexes of USSQ over solifenacin monotherapy. Only slightly higher incidence of dry mouth (P = 0.02) was found with solifenacin versus control. The result demonstrates the safety and efficacy of solifenacin in reducing SRSs, but no significant advantage was found over tamsulosin. In addition, combination of solifenacin and tamsulosin did not show beneficial effects over solifenacin monotherapy. More high quality trials are warranted to further address this issue, however.

  7. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  8. Application of rotational atherectomy in the drug-eluting stent era

    Science.gov (United States)

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  9. [In hospital and mid-term outcome of patients with NIR stent implantation: multicenter ESPORT-NIR registry].

    Science.gov (United States)

    Iñiguez, A; García, E; Seabra, R; Bordes, P; Bethencourt, A; Rigla, J

    2001-05-01

    Despite improvements in the results and techniques of catheter-based revascularization, few studies have evaluated the clinical results of the application of new stent designs. We describe the in-hospital and mid-term outcome of patients undergoing a stent NIR implantation. At least 1 Stent NIR was implanted in 1.004 patients (1.136 lesions) recruited from 50 centers in an international, multicenter, prospective, registry (Spain and Portugal NIR stent registry). Inclusion criteria were objective coronary ischemia related to a severe de novo lesion or first restenosis in native vessels with a reference diameter >= 2.75 mm. The primary end-point was the incidence of major adverse cardiac events within the first 7 months of follow-up. The mean age of the patients was 60 years and 82% were male. Angioplasty was indicated due to unstable angina in 61% of the cases. Stent implantation was successfully achieved in 99.6%. Clinical success (angiographic success without in-hospital major events) was achieved in 98.6% of patients. The rate of angiographic restenosis (> 50% stenosis narrowing) was 16% (CI 95%; 11.7-21.2). The accumulated major cardiac adverse event rate at seven months of follow-up was 8.7%: death (0.9%), acute myocardial infarction (1.2%) and target lesion revascularization (6.6%). In the wide setting of the population included in the ESPORT-NIR registry, stent NIR implantation was a highly effective therapy with a good mid-term clinical and angiographic outcome.

  10. Hemodynamics in stented vertebral artery ostial stenosis based on computational fluid dynamics simulations.

    Science.gov (United States)

    Qiao, Aike; Dai, Xuan; Niu, Jing; Jiao, Liqun

    2016-01-01

    Hemodynamic factors may affect the potential occurrence of in-stent restenosis (ISR) after intervention procedure of vertebral artery ostial stenosis (VAOS). The purpose of the present study is to investigate the influence of stent protrusion length in implantation strategy on the local hemodynamics of the VAOS. CTA images of a 58-year-old female patient with posterior circulation transient ischemic attack were used to perform a 3D reconstruction of the vertebral artery. Five models of the vertebral artery before and after the stent implantation were established. Model 1 was without stent implantation, Model 2-5 was with stent protruding into the subclavian artery for 0, 1, 2, 3 mm, respectively. Computational fluid dynamics simulations based on finite element analysis were employed to mimic the blood flow in arteries and to assess hemodynamic conditions, particularly the blood flow velocity and wall shear stress (WSS). The WSS and the blood flow velocity at the vertebral artery ostium were reduced by 85.33 and 35.36% respectively after stents implantation. The phenomenon of helical flow disappeared. Hemodynamics comparison showed that stent struts that protruded 1 mm into the subclavian artery induced the least decrease in blood speed and WSS. The results suggest that stent implantation can improve the hemodynamics of VAOS, while stent struts that had protruded 1 mm into the subclavian artery would result in less thrombogenesis and neointimal hyperplasia and most likely decrease the risk of ISR.

  11. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  12. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  13. New cerebral lesions at magnetic resonance imaging after carotid artery stenting versus endarterectomy: an updated meta-analysis.

    Directory of Open Access Journals (Sweden)

    Giuseppe Gargiulo

    Full Text Available Carotid endarterectomy (CEA or stenting (CAS are associated with a relatively low rate of clinical events, but diffusion-weighted imaging (DWI is increasingly being used to compare the incidence of new ischemic lesions. Therefore, we conducted an updated meta-analysis on the occurrence of post-procedural new DWI lesions after CAS versus CEA.MEDLINE, Cochrane, ISI Web of Science and SCOPUS databases were searched and 20 studies (2 randomized and 18 non-randomized with a total of 2104 procedures (CAS = 989; CEA = 1115 were included. The incidence of new DWI cerebral lesions was significantly greater after CAS than CEA (40.3% vs 12.2%; 20 studies; 2104 patients; odds ratio [OR] 5.17; 95% confidence interval [CI], 3.31-8.06; p<0.00001. Also peri-procedural stroke (17 studies; 1833 patients; OR 2.01; 95% CI, 1.14-3.55; p=0.02 and stroke or TIA (17 studies; 1833 patients; OR 2.40; 95% CI, 1.42-4.08; p=0.001 were significantly increased after CAS. This latter clinical advantage in the CEA group over CAS was tempered when CEA procedures were performed with shunting in all instead of selective shunting or when CAS was performed with only closed cell stents instead of both closed and open cell stents, however, no significant differences between subgroups emerged.CAS is associated with an increased incidence of post-procedural brain DWI lesions. This greater amount of ischemic burden may also reflect a higher rate of cerebral events after CAS. However, whether recent technical advances mainly for CAS could potentially reduce these ischemic events still remains to be evaluated.

  14. Development of biodegradable magnesium alloy stents with coating

    Directory of Open Access Journals (Sweden)

    Lorenza Petrini

    2014-07-01

    Full Text Available Biodegradable stents are attracting the attention of many researchers in biomedical and materials research fields since they can absolve their specific function for the expected period of time and then gradually disappear. This feature allows avoiding the risk of long-term complications such as restenosis or mechanical instability of the device when the vessel grows in size in pediatric patients. Up to now biodegradable stents made of polymers or magnesium alloys have been proposed. However, both the solutions have limitations. The polymers have low mechanical properties, which lead to devices that cannot withstand the natural contraction of the blood vessel: the restenosis appears just after the implant, and can be ascribed to the compliance of the stent. The magnesium alloys have much higher mechanical properties, but they dissolve too fast in the human body. In this work we present some results of an ongoing study aiming to the development of biodegradable stents made of a magnesium alloy that is coated with a polymer having a high corrosion resistance. The mechanical action on the blood vessel is given by the magnesium stent for the desired period, being the stent protected against fast corrosion by the coating. The coating will dissolve in a longer term, thus delaying the exposition of the magnesium stent to the corrosive environment. We dealt with the problem exploiting the potentialities of a combined approach of experimental and computational methods (both standard and ad-hoc developed for designing magnesium alloy, coating and scaffold geometry from different points of views. Our study required the following steps: i selection of a Mg alloy suitable for stent production, having sufficient strength and elongation capability; ii computational optimization of the stent geometry to minimize stress and strain after stent deployment, improve scaffolding ability and corrosion resistance; iii development of a numerical model for studying stent

  15. A review on biodegradable materials for cardiovascular stent application

    Science.gov (United States)

    Hou, Li-Da; Li, Zhen; Pan, Yu; Sabir, MuhammadIqbal; Zheng, Yu-Feng; Li, Li

    2016-09-01

    A stent is a medical device designed to serve as a temporary or permanent internal scaffold to maintain or increase the lumen of a body conduit. The researchers and engineers diverted to investigate biodegradable materials due to the limitation of metallic materials in stent application such as stent restenosis which requires prolonged anti platelet therapy, often result in smaller lumen after implantation and obstruct re-stenting treatments. Biomedical implants with temporary function for the vascular intervention are extensively studied in recent years. The rationale for biodegradable stent is to provide the support for the vessel in predicted period of time and then degrading into biocompatible constituent. The degradation of stent makes the re-stenting possible after several months and also ameliorates the vessel wall quality. The present article focuses on the biodegradable materials for the cardiovascular stent. The objective of this review is to describe the possible biodegradable materials for stent and their properties such as design criteria, degradation behavior, drawbacks and advantages with their recent clinical and preclinical trials.

  16. A Zr-based bulk metallic glass for future stent applications: Materials properties, finite element modeling, and in vitro human vascular cell response.

    Science.gov (United States)

    Huang, Lu; Pu, Chao; Fisher, Richard K; Mountain, Deidra J H; Gao, Yanfei; Liaw, Peter K; Zhang, Wei; He, Wei

    2015-10-01

    Despite the prevalent use of crystalline alloys in current vascular stent technology, new biomaterials are being actively sought after to improve stent performance. In this study, we demonstrated the potential of a Zr-Al-Fe-Cu bulk metallic glass (BMG) to serve as a candidate stent material. The mechanical properties of the Zr-based BMG, determined under both static and cyclic loadings, were characterized by high strength, which would allow for the design of thinner stent struts to improve stent biocompatibility. Finite element analysis further complemented the experimental results and revealed that a stent made of the Zr-based BMG was more compliant with the beats of a blood vessel, compared with medical 316L stainless steel. The Zr-based BMG was found to be corrosion resistant in a simulated body environment, owing to the presence of a highly stable ZrO2-rich surface passive film. Application-specific biocompatibility studies were conducted using human aortic endothelial cells and smooth muscle cells. The Zr-Al-Fe-Cu BMG was found to support stronger adhesion and faster coverage of endothelial cells and slower growth of smooth muscle cells than 316L stainless steel. These results suggest that the Zr-based BMG could promote re-endothelialization and potentially lower the risk of restenosis, which are critical to improve vascular stent implantation integration. In general, findings in this study raised the curtain for the potential application of BMGs as future candidates for stent applications. Vascular stents are medical devices typically used to restore the lumen of narrowed or clogged blood vessel. Despite the clinical success of metallic materials in stent-assisted angioplasty, post-surgery complications persist due to the mechanical failures, corrosion, and in-stent restenosis of current stents. To overcome these hurdles, strategies including new designs and surface functionalization have been exercised. In addition, the development of new materials with

  17. Stenting of the SFA - indications, techniques,

    International Nuclear Information System (INIS)

    Rieger, J.; Treitl, M.; Reiser, M.; Ruppert, V.

    2006-01-01

    Aggressive risk factor modification, change of eating habits, exercise programs, and forceful antiplatelet therapy are the most important tools for the treatment of PAOD in symptomatic patients suffering from intermittent claudication. There are however no guidelines for revascularization at this stage. Endovascular treatment has been increasingly utilized over the last decade and increasingly displaced vascular surgery. Amongst numerous endovascular techniques beside PTA, stents meanwhile play the most important role due to constant technical progress. Results regarding the rate of restenosis or patency rates still remain worse compared to other vascular beds. This paper gives a review over recent results, currently available stent techniques, and possible indications for the endovascular therapy of an artery, which has turned out to be the biggest ordeal for material and construction of stents. (orig.) [de

  18. Carotid angioplasty and stent placement for restenosis after endarterectomy

    International Nuclear Information System (INIS)

    Kadkhodayan, Yasha; Moran, Christopher J.; Cross, DeWitte T.; Derdeyn, Colin P.

    2007-01-01

    Recurrent carotid stenosis following endarterectomy is a common complication, and reoperation may be associated with increased morbidity. The goal of this study was to determine the procedural safety and long-term complication rates of carotid angioplasty and stenting for recurrent stenosis. Of 248 consecutive carotid angioplasty and/or stenting procedures performed at our institution between March 1996 and November 2005, 83 procedures for recurrent stenosis following endarterectomy were performed in 75 patients (mean age 68 years; 43 men, 32 women) without cerebral protection devices. The patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and long-term complication rates were calculated. Recurrent stenosis was reduced from a mean of 80.6% to no significant stenosis in 82 of 83 procedures. The procedural stroke rate was 3 out of 83 procedures (3.6%). The procedural transient ischemic attack (TIA) rate was 2 out of 83 procedures (2.4%). Mean follow-up was 22.4 months (range 0.1 to 86.7 months) with at least 6 months follow-up for 54 of 83 procedures (65%). There were five TIAs and no strokes on follow-up (new TIAs at 25.5 and 43.4 months; recurrent TIAs at 1, 11.1, and 12 months, all with normal angiograms). The composite 30-day stroke, myocardial infarction, or death rate was 5 of 83 procedures (6.0%). In this series, angioplasty and stenting were effective in relieving stenosis secondary to recurrent carotid disease after endarterectomy, and have low rates of ischemic complications. (orig.)

  19. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  20. Stent-protected angioplasty versus carotid endarterectomy in patients with carotid artery stenosis: meta-analysis of randomized trial data

    International Nuclear Information System (INIS)

    Wiesmann, Martin; Schoepf, Veronika; Brueckmann, Hartmut; Jansen, Olav

    2008-01-01

    Stent-protected angioplasty of carotid artery stenosis may be an alternative to surgical endarterectomy. Results published so far are indecisive, with evidence both in favour of and against this procedure. After the recent publication of two large European multicentre trials (SPACE and EVA-3S) almost 3,000 patients have been included in randomized studies. For this report, we therefore conducted a systematic review of randomized studies that compared endovascular treatment with surgery for carotid stenosis. We evaluated seven trials including 2,973 patients. In our meta-analysis endovascular treatment seemed to carry a slightly higher risk for stroke or death within 30 days after the procedure as compared with surgery (8.2% vs. 6.2%; p = 0.04; OR 1.35), whereas the rates of disabling stroke or death within 30 days did not differ significantly (p = 0.47; n.s.). On the other hand, surgery carried a significantly higher risk for cranial nerve palsy (4.7% vs. 0.2%; p < 0.0001; OR 0.17) and myocardial infarction (2.3% vs. 0.9%; p = 0.03; OR 0.37). Long-term effects of both methods still need to be evaluated. Two other large multicentre trials (ICSS and CREST) are ongoing. Results of these studies will increase the database to about 7,000 randomized patients. Future meta-analyses should then allow definitive treatment recommendations. (orig.)

  1. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    International Nuclear Information System (INIS)

    Han, Dong-Wook; Lee, Jun Jae; Jung, Duk-Young; Park, Jong-Chul; Hyon, Suong-Hyu

    2009-01-01

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-ε-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  2. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong-Wook [Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 609-735 (Korea, Republic of); Lee, Jun Jae [Division of Advanced Fibro-Science, Kyoto Institute of Technology, Kyoto 606-8585 (Japan); Jung, Duk-Young [Senior Products Industrial Center, Busan Techno-Park, Busan-617-030 (Korea, Republic of); Park, Jong-Chul [Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 120-752 (Korea, Republic of); Hyon, Suong-Hyu, E-mail: nanohan@pusan.ac.k, E-mail: biogen@frontier.kyoto-u.ac.j [Department of Medical Simulation Engineering, Institute for Frontier Medical Sciences, Kyoto University, Kyoto 606-8507 (Japan)

    2009-08-15

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-epsilon-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  3. Novel nanocrystalline diamond coating of coronary stents reduces neointimal hyperplasia in pig model

    Czech Academy of Sciences Publication Activity Database

    Kočka, V.; Jirásek, T.; Taylor, Andrew; Fendrych, František; Rezek, Bohuslav; Šimůnková, Z.; Mrázová, I.; Toušek, P.; Mistrík, J.; Mandys, V.; Nesládek, M.

    2014-01-01

    Roč. 20, č. 1 (2014), s. 65-76 ISSN 1205-6626 R&D Projects: GA AV ČR KAN200100801 Institutional support: RVO:68378271 Keywords : stents * nanotechnology * restenosis * optical coherence tomography * diamond Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.758, year: 2013

  4. Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis.

    Science.gov (United States)

    Han, Xinwei; Al-Tariq, Quazi; Zhao, Yanle; Li, Lei; Cheng, Zhe; Wang, Huaqi; Liu, Chao; Jiao, Dechao; Wu, Gang

    2017-08-01

    To address the limitations of silicone stents, we designed a hinged self-expandable covered metallic stent. The aim of this study was to evaluate the safety and efficacy of the customized stents in clinical applications. This was a retrospective analysis. Under conscious sedation and local anesthesia, the stents were implanted or removed by interventional radiologists, with fluoroscopic guidance. Of 24 patients with benign main bronchial stenosis, stents were successfully placed in 21 (87.5%). The low-pressure balloon before dilation failed in 1 case (4.17%) of left main bronchial cicatricial stenosis. In 2 other cases (8.33%), stent placement was abandoned. Stents were successfully removed between 29 and 103 days after the procedure. After stent removal, the follow-up lasted for at least 12 months. Restenosis occurred only in 1 case (4.55%) owing to bronchial collapse 3 days after stent removal. Dyspnea occurred in another case (4.55%) at 2 months after retrieval; recurrence was confirmed using bronchoscopy, leading to a left pneumonectomy. The described procedure is safe and easy to be performed and avoids the use of intubation, bronchoscopy, and general anesthesia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Zotarolimus-eluting stent for the treatment of recurrent, severe carotid artery in-stent stenosis in the TARGET-CAS population.

    Science.gov (United States)

    Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr

    2012-06-01

    To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.

  6. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  7. Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

    International Nuclear Information System (INIS)

    Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.

    2010-01-01

    Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

  8. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  9. The application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement

    International Nuclear Information System (INIS)

    Wei Ning; Xu Hao; Zu Maoheng; Gu Yuming; Li Gang; Zhang Qingqiao; Xu Wei; Cui Yanfeng; Liu Hongtao; Wang Wenliang

    2012-01-01

    Objective: To evaluate the application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement. Methods: Thirty-one patients treated with tracheal stents were retrospectively analyzed, of which there were 27 malignant tracheal stenosis, 2 benign tracheal stenosis, 1 bronchial remnant fistula and 1 gastroesophageal anastomosis tracheal fistula. The spiral-CT and 3D-imagings were analyzed and the location, shape and complication of the stents were assessed. Results: Thirty-one patients were treated with 8 Z-type stainless steel stents and 28 Ni-Ti memory alloy stents. The stents of 22 cases remained patent in the original position and restenosis was occurred in 5 cases, migration in 3 cases and fracture in 1 case. All the CT features were performed and reconstructed on the workstation, using multiplanar reconstruction, volume rendering, and CT virtual endoscopy. The location of tracheal stenosis and fistula were showed in different angle, and the location, shape of the stents, and the complications (such as restenosis, fracture) as well. Conclusion: Spiral-CT and 3D-imaging is a rapid, simple and effective method in assessing tracheal stent implantation and complication, therefore, it is of great value in clinical practice. (authors)

  10. Covered versus uncovered self-expandable metal stents for malignant biliary strictures: A meta-analysis and systematic review.

    Science.gov (United States)

    Moole, Harsha; Bechtold, Matthew L; Cashman, Micheal; Volmar, Fritz H; Dhillon, Sonu; Forcione, David; Taneja, Deepak; Puli, Srinivas R

    2016-09-01

    Self-expandable metal stents (SEMS) are used for palliating inoperable malignant biliary strictures. It is unclear if covered metal stents are superior to uncovered metal stents in these patients. We compared clinical outcomes in patients with covered and uncovered stents. Studies using covered and uncovered metallic stents for palliation in patients with malignant biliary stricture were reviewed. Articles were searched in MEDLINE, PubMed, and Ovid journals. Fixed and random effects models were used to calculate the pooled proportions. Initial search identified 1436 reference articles, of which 132 were selected and reviewed. Thirteen studies (n = 2239) for covered and uncovered metallic stents which met the inclusion criteria were included in this analysis. Odds ratio for stent occlusion rates in covered vs. uncovered stents was 0.79 (95 % CI = 0.65 to 0.96). Survival benefit in patients with covered vs. uncovered stents showed the odds ratio to be 1.29 (95 % CI = 0.95 to 1.74). Pooled odds ratio for migration of covered vs. uncovered stents was 9.9 (95 % CI = 4.5 to 22.3). Covered stents seemed to have significantly lesser occlusion rates, increased odds of migration, and increased odds of pancreatitis compared to uncovered stents. There was no statistically significant difference in the survival benefit, overall adverse event rate, and patency period of covered vs. uncovered metal stents in patients with malignant biliary strictures.

  11. Intraarterial 192Ir high-dose-rate brachytherapy for prophylaxis of restenosis after femoropopliteal percutaneous transluminal angioplasty: the prospective randomized Vienna-2-trial radiotherapy parameters and risk factors analysis

    International Nuclear Information System (INIS)

    Pokrajac, Boris; Poetter, Richard; Maca, Thomas; Fellner, Claudia; Mittlboeck, Martina; Ahmadi, Ramazanali; Seitz, Wolfgang; Minar, Erich

    2000-01-01

    Purpose: The aim of the Vienna-2-trial was to compare the restenosis rate of femoropopliteal arteries after percutaneous transluminal angioplasty (PTA) with or without intraarterial high-dose-rate (HDR) brachytherapy (BT) using an 192 Ir source. Materials and Methods: A prospective, randomized trial was conducted from 11/96 to 8/98. A total of 113 patients (63 men, 50 women), with a mean age of 71 years (range, 43-89 years) were included. Inclusion criteria were (1) claudication or critical limb ischemia, (2) de-novo stenosis of 5 cm or more, (3) restenosis after former PTA of any length, and (4) no stent implantation. Patients were randomized after successful PTA for BT vs. no further treatment. A well-balanced patient distribution was achieved for the criteria used for stratification, as there were 'de-novo stenosis vs. restenosis after former PTA', 'stenosis vs. occlusion', 'claudication vs. critical limb ischemia' and above these for 'diabetes vs. nondiabetes'. PTA length was not well balanced between the treatment arms: a PTA length of 4-10 cm was seen in 19 patients in the PTA alone group and in 11 patients in the PTA+BT group, whereas a PTA length of greater than10 cm was seen in 35 patients and 42 patients, respectively. A dose of 12 Gy was prescribed in 3-mm distance from the source axis. According to AAPM recommendations, the dose was 6.8 Gy in 5-mm distance (vessel radius + 2 mm). Primary endpoint of the study was femoropopliteal patency after 6 months. Results: PTA and additional BT were feasible and well tolerated by all 57 pts in this treatment arm. No acute, subacute, and late adverse side effects related to BT were seen after a mean follow up of 12 months (6-24 months) in 107 patients (PTA n = 54; PTA+ BT n = 53). Crude restenosis rate at 6 months was in the PTA arm 54% vs. 28% in the PTA + BT arm (χ 2 test; p 10 cm) showed significant decrease of the restenosis rate, if BT was added. Significant reduction was not achieved in diabetes patients

  12. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    Science.gov (United States)

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  13. Self-expendable metallic stents for palliative treatment of malignant esophagogastric strictures: experiences in 103 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ah; Do, Young Soo; Lee, Byung Hee; Oh, Hoon Il; Kim, Soo Ah; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the effects and complication of self-expandable metallic stent for the treatment of malignant esophagogastric strictures. From September 1991 to March 1995, 110 stents were placed under fluoroscopic guidance in 103 patients. Of the 103 patients, there were 73 patients with esophageal cancer, 14 patients with gastric cancer, 12 patients with recurrence after surgery, three patients with esophageal compression by metastatic mediastinal lymphadenopathy, and one patient with esophageal invasion by lung cancer. Seventeen patients had esophagorespiratory fistulas. Under fluoroscopic guidance, 113 self-expandable metallic stents (99 Song stents, 14 Strecker stents) were placed in 103 patients. After stent placement, 68 (66%) of the patients could ingest solid food, 26 (25.2%) could ingest soft food whereas three (2.9%) were not able to have food. Esophagorespiratory fistulas were occluded immediately after stent insertion. All stents were placed without any technical failures or procedural morbidity or mortality. Complications included restenosis in 13, gastroesophageal reflux in 11, stent tube migration in eight, massive bleeding in four, delayed esophageal perforation in one, stent obstruction by food impaction in one patient. Self-expandable metallic stent seems to be relatively safe and effective procedure in the palliative treatment of malignant esophagogastric stricture.

  14. Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Susumu, E-mail: susumu1029@gmail.com; Kikuchi, Naoshi; Ichikawa, Atsuo; Sano, Go; Satoh, Keita; Sugino, Keishi; Isobe, Kazutoshi; Takai, Yujiro [Toho University School of Medicine, Department of Respiratory Medicine (Japan); Shibuya, Kazutoshi [Toho University School of Medicine, Department of Pathology (Japan); Homma, Sakae [Toho University School of Medicine, Department of Respiratory Medicine (Japan)

    2013-08-01

    Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

  15. Analysis of trends and prospects regarding stents for human blood vessels.

    Science.gov (United States)

    Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo

    2018-01-01

    The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used

  16. Magnetizable stent-grafts enable endothelial cell capture

    Science.gov (United States)

    Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

  17. New stent design for use in small coronary arteries during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Juan F Granada

    2010-10-01

    Full Text Available Juan F Granada1, Barbara A Huibregtse2, Keith D Dawkins21The Jack H Skirball Center for Cardiovascular Research, Cardiovascular Research Foundation, Columbia University Medical Center, New York, NY, USA; 2Boston Scientific Corporation, Natick, MA, USAAbstract: Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel, and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches, intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001, instent binary restenosis (13.0% versus 38.1%, P < 0.001, and target lesion revascularization (5.8% versus 17.6%, P < 0.001 at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03 and instent binary restenosis (13.0% versus 25.9%, P = 0.02 when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS

  18. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.

    Science.gov (United States)

    Poerner, Tudor C; Otto, Sylvia; Gassdorf, Johannes; Nitsche, Kristina; Janiak, Florian; Scheller, Bruno; Goebel, Björn; Jung, Christian; Figulla, Hans R

    2014-12-01

    In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64±9.65% in BMS+DEB versus 4.93±9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7±7.8 versus 11.0±5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8±11.9 versus 16.9±10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5±13.8% versus 36.8±15.6%; P=0.409) was found. Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up. http://www.clinicaltrials.gov. Unique identifier: NCT01056744. © 2014 American Heart Association, Inc.

  19. Fractura de stent sirolimus: una causa de restenosis tardía

    Directory of Open Access Journals (Sweden)

    William Amaya

    2013-12-01

    Full Text Available El primer caso de fractura de stent farmacológico en arterias coronarias fue publicado en 2004, y aunque es un evento infrecuente, las implicaciones diagnósticas y terapéuticas siguen siendo un reto. Se presenta el caso de un paciente de género masculino, de 49 años de edad, portador de dos stents medicados, con antedecedente de nuevo evento coronario y diagnóstico de fractura de dichos dispositivos a través de cateterismo.

  20. A higher volume of fibrotic tissue on virtual histology prior to coronary stent implantation predisposes to more pronounced neointima proliferation.

    Science.gov (United States)

    Haine, Steven; Wouters, Kristien; Miljoen, Hielko; Vandendriessche, Tom; Claeys, Marc; Bosmans, Johan; Vrints, Christiaan

    2018-04-01

    Since neointima smooth muscle cells (SMC) mainly originate from the vessel wall, we investigated whether atherosclerotic plaque composition influences subsequent in-stent neointima proliferation and restenosis. We performed intravascular ultrasound (IVUS) with virtual histology in 98 patients prior to elective bare-metal stent (BMS) implantation in de novo coronary artery lesions. Virtual histology variables pre-percutaneous coronary intervention (PCI) were related to in-stent neointima proliferation six months after implantation assessed as late luminal loss of 0.88 mm (interquartile range (IQR) 0.37-1.23 mm) on angiography and as maximal percentage area stenosis of 42% (IQR 33-59%) and percentage volume intima hyperplasia of 27% (IQR 20-36%) on IVUS. A ridge-trace based multiple linear regression model was constructed to account for multicollinearity of the virtual histology variables and was corrected for implanted stent length (18 mm, IQR 15-23 mm), stent diameter (3.0 mm, IQR 2.75-3.5 mm) and lesion volume (146 mm³, IQR 80-201 mm³) prior to PCI. Fibrous tissue volume prior to PCI (49 mm³, IQR 30-77 mm³) was significantly and independently related to late luminal loss (p = .038), maximal percentage area stenosis (p = .041) and percentage volume intima hyperplasia (p = .004). Neither absolute nor relative amounts of fibrofatty, calcified or necrotic core tissue appeared related to any of the restenosis parameters. Subgroup analysis after exclusion of acute coronary syndrome (ACS) patients yielded similar results. Lesions with more voluminous fibrotic tissue pre-PCI show more pronounced in-stent neointima proliferation, even after correction for lesion plaque volume.

  1. Experimental comparison study of the tissue characteristics in transjugular intrahepatic portosystemic shunt and vascular stent

    International Nuclear Information System (INIS)

    Lu Qin; An Yanli; Deng Gang; Fang Wen; Zhu Guangyu; Niu Huanzhang; Yu Hui; Li Guozhao; Teng Gaojun; Wang Zhen; Wei Xiaoying

    2009-01-01

    Objective: To investigate the tissue characteristics within vascular stent and transjugular intrahepatic portosystemic shunt(TIPS) on swine and to provide more information for the understanding and prevention of vascular stent and TIPS restenosis. Methods: Animal models for TIPS were built in 6 swine and vascular stents were implanted in iliac veins simultaneously. 14-28 days after the operation, the 6 swine were killed to remove the TIPS and vascular stent and the pathological examinations were performed on the tissues within the shunt and stent. The similarities and differences of the tissues within the shunt and stent were analyzed with Krttskal Wallis test. Results: Restenosis of TIPS occurred in 4 models and complete occlusion were seen in 2, while all vascular stents were patent and coated with a thin layer of intimal tissue. Electron microscopic results showed that the tissues in restenotic TIPS were loose and with more extra matrix and fibers, and less smooth muscle, fibroblastic and myofibroblastic cells with different and irregular shape and rich secretory granules. The tissues in patent TIPS contained more extra fibers, smooth muscle and fibroblastic cells with normal organelle. The intimal tissues in vascular stent contained more fibers and fibroblasts cells, less smooth muscle cells. On immunohistochemical staining, the tissues in restenotic and patent TIPS as well as the intimal tissues in vascular stent had strong positive expression for anti-SMC- actin-α, the expression were gradually weakened for PCNA, the intimal tissues in vascular stent had a strong positive expression for vimentin, while the expression of the tissues in restenotic and patent TIPS were weakened gradually. For myoglobulin, the tissues in restenotic TIPS had weakly positive expression, the expression in patent TIPS and vascular stent were almost negative. Western blot results for TGF-β showed that the absorbance ratios of the intima tissues in vascular stent, normal vascular

  2. Impaired health status in Type D patients following PCI in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Denollet, Johan; Ong, Andrew T L

    2007-01-01

    Drug-eluting stenting reduces restenosis post-percutaneous coronary intervention (PCI), but subgroups of patients may not benefit optimally from this procedure. We examined the impact of Type D personality on health status over time and the clinical relevance of Type D as a predictor of impaired...... health status at 12 months in unselected post-PCI patients....

  3. Surface Topographical Modification of Coronary Stent: A Review

    Science.gov (United States)

    Tan, C. H.; Muhamad, N.; Abdullah, M. M. A. B.

    2017-06-01

    Driven by the urge of mediating the inflammatory response from coronary stent implant to improve patency rates of the current coronary stent, concern has been focusing on reducing the risk of in-stent restenosis and thrombosis for long-term safety. Surface modification approach has been found to carry great potential due to the surface is the vital parts that act as a buffer layer between the biomaterial and the organic material like blood and vessel tissues. Nevertheless, manipulating cell response in situ using physical patterning is very complex as the exact mechanism were yet elucidated. Thus, the aim of this review is to summarise the recent efforts on modifying the surface topography of coronary stent at the micro- and nanometer scale with the purpose of inducing rapid in situ endothelialization to regenerate a healthy endothelium layer on biomaterial surface. In particular, a discussion on the surface patterns that have been investigated on cell selective behaviour together with the methods used to generate them are presented. Furthermore, the probable future work involving the surface modification of coronary stent were indicated.

  4. Similarities and differences in coatings for magnesium-based stents and orthopaedic implants

    Directory of Open Access Journals (Sweden)

    Jun Ma

    2014-07-01

    Full Text Available Magnesium (Mg-based biodegradable materials are promising candidates for the new generation of implantable medical devices, particularly cardiovascular stents and orthopaedic implants. Mg-based cardiovascular stents represent the most innovative stent technology to date. However, these products still do not fully meet clinical requirements with regards to fast degradation rates, late restenosis, and thrombosis. Thus various surface coatings have been introduced to protect Mg-based stents from rapid corrosion and to improve biocompatibility. Similarly, different coatings have been used for orthopaedic implants, e.g., plates and pins for bone fracture fixation or as an interference screw for tendon-bone or ligament-bone insertion, to improve biocompatibility and corrosion resistance. Metal coatings, nanoporous inorganic coatings and permanent polymers have been proved to enhance corrosion resistance; however, inflammation and foreign body reactions have also been reported. By contrast, biodegradable polymers are more biocompatible in general and are favoured over permanent materials. Drugs are also loaded with biodegradable polymers to improve their performance. The key similarities and differences in coatings for Mg-based stents and orthopaedic implants are summarized.

  5. Impact of Chronic Renal Failure on Safety and Effectiveness of Paclitaxel-Eluting Stents for Femoropopliteal Artery Disease: Subgroup Analysis from Zilver PTX Post-Market Surveillance Study in Japan.

    Science.gov (United States)

    Ogawa, Yukihisa; Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Saunders, Alan T; Dake, Michael D

    2017-11-01

    Favorable long-term outcomes of the Zilver PTX drug-eluting stent (DES) in femoropopliteal lesions have been demonstrated. Chronic renal failure (CRF) has been shown to be a risk factor for restenosis and decreased limb salvage. The results of the DES in patients with CRF have not previously been reported. This study compares the results with the DES in patients with CRF and those without CRF. This retrospective analysis from the Zilver PTX Japan Post-Market Surveillance Study included 321 patients with CRF and 584 patients without CRF. Outcomes included freedom from target lesion revascularization (TLR) and patency. Of the patients included in this subgroup analysis, 2-year data were available for 209 patients in the CRF group and 453 patients in the non-CRF group. The two groups were similar in terms of lesion length and the frequency of in-stent restenosis. Critical limb ischemia, severe calcification, and diabetes were more common in patients with CRF, whereas total occlusion was more common in patients without CRF. Freedom from TLR rates were 81.4 versus 84.9% (p = 0.24), and patency rates were 70.7 versus 70.3% (p = 0.95) in patients with and without CRF at 2 years, respectively. This is the first comparative study of the DES in femoropopliteal artery lesions in patients with and without CRF. These results indicate that the DES placed in femoropopliteal artery lesions of CRF patients is safe and effective with similar patency and TLR rates to patients without CRF. Level 3, Post-Market Surveillance Study.

  6. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    Science.gov (United States)

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  7. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  8. TIDES-ACS Trial: comparison of titanium-nitride-oxide coated bio-active-stent to the drug (everolimus)-eluting stent in acute coronary syndrome. Study design and objectives.

    Science.gov (United States)

    Colkesen, E B; Eefting, F D; Rensing, B J; Suttorp, M J; Ten Berg, J M; Karjalainen, P P; Van Der Heyden, J A

    2015-02-01

    Drug-eluting stents (DES), delivering antiproliferative drugs from a durable polymer, have shown to reduce in-stent restenosis after percutaneous coronary intervention (PCI) compared to bare-metal stents (BMS). However, they have been associated with a hypersensitivity reaction, delayed healing, and incomplete endothelialization, which may contribute to an increased risk of late stent thrombosis. Consequently, a prolonged duration of dual antiplatelet therapy (DAPT) is needed, with an increased risk of bleeding complication. A number of stent technologies are being developed in an attempt to modify late thrombotic events and DAPT duration. The Optimax™ stent is such a novel, next generation bioactive stent (BAS), in which a thicker layer of titanium-nitride-oxide coating is inserted over the stent struts. The rationale of this is to obtain more efficient and rapid vascular healing at the site of the stent implantation. The aim of TIDES-ACS Trial is to compare clinical outcome in patients presenting with ACS, treated with PCI using Optimax-BAS versus Synergy™-EES. Second objective is to explore whether the Optimax™-BAS use is superior compared with Synergy™-EES use with respect of hard end points (cardiac death, myocardial infarction [MI] and major bleeding). A prospective, randomized, multicenter trial (ClinicalTrials.gov Identifier: NCT02049229), will be conducted in interventional centres in Finland (six centres), France (five centres) and Holland (two centres), including a total of 1800 patients.

  9. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite...... a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P... coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  10. Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results

    International Nuclear Information System (INIS)

    Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre

    2003-01-01

    The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems

  11. Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.

    Science.gov (United States)

    Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki

    2017-10-01

    Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.

  12. Complications of stent placement in patients with esophageal cancer: A systematic review and network meta-analysis.

    Directory of Open Access Journals (Sweden)

    Amin Doosti-Irani

    Full Text Available Palliative treatments and stents are necessary for relieving dysphagia in patients with esophageal cancer. The aim of this study was to simultaneously compare available treatments in terms of complications.Web of Science, Medline, Scopus, Cochrane Library and Embase were searched. Statistical heterogeneity was assessed using the Chi2 test and was quantified by I2. The results of this study were summarized in terms of Risk Ratio (RR. The random effects model was used to report the results. The rank probability for each treatment was calculated using the p-score.Out of 17855 references, 24 RCTs reported complications including treatment related death (TRD, bleeding, stent migration, aspiration, severe pain and fistula formation. In the ranking of treatments, thermal ablative therapy (p-score = 0.82, covered Evolution® stent (p-score = 0.70, brachytherapy (p-score = 0.72 and antireflux stent (p-score = 0.74 were better treatments in the network of TRD. Thermal ablative therapy (p-score = 0.86, the conventional stent (p-score = 0.62, covered Evolution® stent (p-score = 0.96 and brachytherapy (p-score = 0.82 were better treatments in the network of bleeding complications. Covered Evolution® (p-score = 0.78, uncovered (p-score = 0.88 and irradiation stents (p-score = 0.65 were better treatments in network of stent migration complications. In the network of severe pain, Conventional self-expandable nitinol alloy covered stent (p-score = 0.73, polyflex (p-score = 0.79, latex prosthesis (p-score = 0.96 and brachytherapy (p-score = 0.65 were better treatments.According to our results, thermal ablative therapy, covered Evolution® stents, brachytherapy, and antireflux stents are associated with a lower risk of TRD. Moreover, thermal ablative therapy, conventional, covered Evolution® and brachytherapy had lower risks of bleeding. Overall, fewer complications were associated with covered Evolution® stent and brachytherapy.

  13. Complications of stent placement in patients with esophageal cancer: A systematic review and network meta-analysis

    Science.gov (United States)

    Doosti-Irani, Amin; Mansournia, Mohammad Ali; Rahimi-Foroushani, Abbas; Haddad, Peiman

    2017-01-01

    Background Palliative treatments and stents are necessary for relieving dysphagia in patients with esophageal cancer. The aim of this study was to simultaneously compare available treatments in terms of complications. Methods Web of Science, Medline, Scopus, Cochrane Library and Embase were searched. Statistical heterogeneity was assessed using the Chi2 test and was quantified by I2. The results of this study were summarized in terms of Risk Ratio (RR). The random effects model was used to report the results. The rank probability for each treatment was calculated using the p-score. Results Out of 17855 references, 24 RCTs reported complications including treatment related death (TRD), bleeding, stent migration, aspiration, severe pain and fistula formation. In the ranking of treatments, thermal ablative therapy (p-score = 0.82), covered Evolution® stent (p-score = 0.70), brachytherapy (p-score = 0.72) and antireflux stent (p-score = 0.74) were better treatments in the network of TRD. Thermal ablative therapy (p-score = 0.86), the conventional stent (p-score = 0.62), covered Evolution® stent (p-score = 0.96) and brachytherapy (p-score = 0.82) were better treatments in the network of bleeding complications. Covered Evolution® (p-score = 0.78), uncovered (p-score = 0.88) and irradiation stents (p-score = 0.65) were better treatments in network of stent migration complications. In the network of severe pain, Conventional self-expandable nitinol alloy covered stent (p-score = 0.73), polyflex (p-score = 0.79), latex prosthesis (p-score = 0.96) and brachytherapy (p-score = 0.65) were better treatments. Conclusion According to our results, thermal ablative therapy, covered Evolution® stents, brachytherapy, and antireflux stents are associated with a lower risk of TRD. Moreover, thermal ablative therapy, conventional, covered Evolution® and brachytherapy had lower risks of bleeding. Overall, fewer complications were associated with covered Evolution® stent and

  14. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  15. Brachytherapy on restenosis. 32P radioisotope in animal model

    International Nuclear Information System (INIS)

    Bergoc, R.; Rivera, E.; Cocca, C.; Martin, G.; Cricco, G.; Croci, M.; Guzman, L.

    2000-01-01

    Despite a notorious decline in age-adjusted death rates for cardiovascular pathologies, coronary artery disease still remains as the main cause of mortality above the age of 40 in men and 60 in women. More than 25% of death in persons over the age of 35 are due to coronary disease. In about 50% of men and 30% of women, the first manifestation of the disease is an acute myocardial infarction and 10% a sudden cardiac death. In Argentina it is estimated that in 1998 about 100.000-115.000 people suffered as first manifestation of coronary illness a myocardial acute infarct. Angioplasty has an important and well established site in the treatment of the coronary illness and restenosis represents the principal complication of this method for myocardial re-vascularization. About a 35-40% of treated arteries present restenosis within the first six month the intervention with the concomitant need of re-interventions, re-hospitalizations, by-pass surgery, work discontinuity and the high cost for the health system. A number of drugs were tested as anti-restenosis: anticoagulants, aspirin, antispasmodics and lipid-lowering agents but none was clearly efficient; also, experimental studies in which intravascular irradiation with different source types and energies, radiation doses and doses rate to prevent restenosis was utilized; however, there is no consensus in many aspects of this intravascular brachytherapy. The first step in this work was to induce the experimental model in rabbits. Afterwards, by means of the balloon methodology and stent implantation, brachytherapy experiments were carried out to evaluate the biological effect on different layers of arteries, with different Doses using a beta particle emitting radioisotope ( 32 P). The arteriosclerotic lesions were induced in New Zealand rabbits through the administration of a diet with high cholesterol content. Angioplastic interventions on femoral arteries were done with balloon methodology and controlled by fluoroscopy

  16. Determining clinical benefits of drug-eluting coronary stents according to the population risk profile: a meta-regression from 31 randomized trials.

    Science.gov (United States)

    Moreno, Raul; Martin-Reyes, Roberto; Jimenez-Valero, Santiago; Sanchez-Recalde, Angel; Galeote, Guillermo; Calvo, Luis; Plaza, Ignacio; Lopez-Sendon, Jose-Luis

    2011-04-01

    The use of drug-eluting stents (DES) in unfavourable patients has been associated with higher rates of clinical complications and stent thrombosis, and because of that concerns about the use of DES in high-risk settings have been raised. This study sought to demonstrate that the clinical benefit of DES increases as the risk profile of the patients increases. A meta-regression analysis from 31 randomized trials that compared DES and bare-metal stents, including overall 12,035 patients, was performed. The relationship between the clinical benefit of using DES (number of patients to treat [NNT] to prevent one episode of target lesion revascularization [TLR]), and the risk profile of the population (rate of TLR in patients allocated to bare-metal stents) in each trial was evaluated. The clinical benefit of DES increased as the risk profile of each study population increased: NNT for TLR=31.1-1.2 (TLR for bare-metal stents); prisk profile of each study population, since the effect of DES in mortality, myocardial infarction, and stent thrombosis, was not adversely affected by the risk profile of each study population (95% confidence interval for β value 0.09 to 0.11, -0.12 to 0.19, and -0.03 to-0.15 for mortality, myocardial infarction, and stent thrombosis, respectively). The clinical benefit of DES increases as the risk profile of the patients increases, without affecting safety. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS

    Science.gov (United States)

    Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan

    2018-01-01

    Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790

  18. Drug-Coated Balloon Angioplasty: A Novel Treatment for Pulmonary Artery In-Stent Stenosis in a Patient with Williams Syndrome.

    Science.gov (United States)

    Cohen, Jennifer L; Glickstein, Julie S; Crystal, Matthew A

    2017-12-01

    A 20-month-old boy with Williams syndrome had undergone multiple surgical and catheter-based interventions for resistant peripheral pulmonary arterial stenoses with eventual bilateral stent placement and conventional balloon angioplasty. He persistently developed suprasystemic right ventricular (RV) pressure. Angioplasty with a drug-coated balloon (DCB) was performed for in-stent restenosis and to remodel his distal pulmonary vessels bilaterally. This resulted in immediate improvement in the in-stent stenosis and resultant decrease in RV pressure. Follow-up catheterization two months later continued to show long-lasting improvement in the in-stent stenosis. We hypothesize that the anti-proliferative effects of DCBs may be of benefit in the arteriopathy associated with Williams syndrome. We report this as a novel use of a DCB in the pulmonary arterial circulation in a patient with Williams syndrome.

  19. Covered Metallic Stents With an Anti-Migration Design vs. Uncovered Stents for the Palliation of Malignant Gastric Outlet Obstruction: A Multicenter, Randomized Trial

    Science.gov (United States)

    Lee, Hyuk; Min, Byung-Hoon; Lee, Jeong Hoon; Shin, Cheol Min; Kim, Younjoo; Chung, Hyunsoo; Lee, Sang Hyub

    2015-01-01

    OBJECTIVES: Previous studies reported comparable stent patency between covered self-expandable metallic stents (SEMS) and uncovered SEMS (UCS) for palliation of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the efficacy and safety of the newly developed WAVE-covered SEMS (WCS), which has an anti-migration design, compared with UCS in gastric cancer patients with symptomatic GOO. METHODS: A total of 102 inoperable gastric cancer patients with symptomatic GOO were prospectively enrolled from five referral centers and randomized to undergo UCS or WCS placement. Stent patency and recurrence of obstructive symptoms were assessed at 8 weeks and 16 weeks after stent placement. RESULTS: At the 8-week follow-up, both stent patency rates (72.5% vs. 62.7%) and re-intervention rates (19.6% vs. 19.6%) were comparable between the WCS and the UCS groups. Both stent stenosis (2.4% vs. 8.1%) and migration rates (9.5% vs. 5.4%) were comparable between WCS and UCS groups. At the 16-week follow-up, however, the WCS group had a significantly higher stent patency rate than the UCS group (68.6% vs. 41.2%). Re-intervention rates in the WCS and UCS groups were 23.5% and 39.2%, respectively. Compared with the UCS group, the WCS group had a significantly lower stent restenosis rate (7.1% vs. 37.8%) and a comparable migration rate (9.5% vs. 5.4%). Overall stent patency was significantly longer in the WCS group than in the UCS group. No stent-associated significant adverse events occurred in either the WCS or UCS groups. In the multivariate analysis, WCS placement and chemotherapy were identified as independent predictors of 16-week stent patency. CONCLUSIONS: WCS group showed comparable migration rate and significantly more durable long-term stent patency compared with UCS group for the palliation of GOO in patients with inoperable gastric cancer. PMID:26372507

  20. Advances in Study of Absorbable Metal Stent in Coronary Artery%冠状动脉内可吸收金属支架的研究进展

    Institute of Scientific and Technical Information of China (English)

    刘艳青

    2012-01-01

    冠状动脉内支架植入是目前广泛应用的冠心病治疗手段,但支架内狭窄和晚期血栓形成影响冠状动脉支架远期疗效和安全性,长期应用抗血小板药物所带来的不良反应以及经济上给患者造成的负担,这些都限制了冠状动脉支架的进一步应用.生物可吸收金属支架具有与裸金属支架相当的支撑力及良好生物相容性,可有效降低再狭窄率和血栓形成,临床应用前景十分广阔.%Currently, coronary stents are widely used in the treatment of coronary heart disease. However, the major limitations of stents are in-stent restenosis and late thrombosis. These , which effect the long-term efficiency and safety of the stents. Moreover, prolonged antiplatelet therapy can have many adverse effects and economic burdens for a patient , and these factors limit the further development of stents. The use of a bioabsorbable metal stent which could provide the same mechanical properties compared to the bare metal stent and but with good bio-compatibility, could reduce the rate of restenosis and thrombosis. It owns a bright future in clinical coronary stents.

  1. Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.

    Science.gov (United States)

    Mennuni, Marco G; Pagnotta, Paolo A; Stefanini, Giulio G

    2016-02-01

    Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.

  2. Assessment of coronary artery stent patency by electron-beam CT

    International Nuclear Information System (INIS)

    Knollmann, Friedrich D.; Felix, Roland; Moeller, Joerg; Gebert, Axel; Bethge, Christian

    2004-01-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  3. Assessment of coronary artery stent patency by electron-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, Friedrich D.; Felix, Roland [Department of Radiology, Charite, Campus Virchow-Klinikum, Humboldt-University, Augustenburger Platz 1, 13353, Berlin (Germany); Moeller, Joerg; Gebert, Axel; Bethge, Christian [Department of Cardiology, Juedisches Krankenhaus, Berlin (Germany)

    2004-08-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  4. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  5. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  6. Brachytherapy for the prevention of neointimal hyperplasia in the canine inferior vena cava after stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Isota, Masayuki; Kaminou, Toshio; Sakai, Yukimasa; Nakamura, Kenji; Yamada, Ryusaku [Osaka City Univ. (Japan). Medical School

    2002-06-01

    The aim of this study was to evaluate the efficacy of brachytherapy for preventing neointimal hyperplasia in the inferior vena cava (IVC) after stent placement. Sixteen beagles underwent Z-stent placement in the IVC and the aorta. For 8 of 16 beagles, irradiation (15 Gy) was delivered endoluminally to the stented segments of each vessel immediately after stent placement using the {sup 192}Ir. All animals were sacrificed after 6 weeks for morphometric and histopathologic examination. Morphometrically, neointimal thickness in the IVC of the radiation group was significantly decreased compared with the control group as well as that in the aorta (p<0.05). Histopathologic findings showed the neointima in the IVC of the control group contained markedly organization of thrombus and neovascularization though that in the IVC of the radiation group consisted mainly of smooth muscle cells without organization of thrombus and neovascularization. From these data intravenous irradiation may prevent clinical restenosis after stent placement. (author)

  7. In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    Science.gov (United States)

    Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed

    2017-06-01

    Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.

  8. Microfocal X-ray computed tomography post-processing operations for optimizing reconstruction volumes of stented arteries during 3D computational fluid dynamics modeling.

    Science.gov (United States)

    Ladisa, John F; Olson, Lars E; Ropella, Kristina M; Molthen, Robert C; Haworth, Steven T; Kersten, Judy R; Warltier, David C; Pagel, Paul S

    2005-08-01

    Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.

  9. A systematic review and meta-analysis of randomized trials and prospective studies comparing covered and bare self-expandable metal stents for the treatment of malignant obstruction in the digestive tract.

    Science.gov (United States)

    Yang, Zhiping; Wu, Qiong; Wang, Fang; Ye, Xiaofei; Qi, Xingshun; Fan, Daiming

    2013-01-01

    Self-expandable metal stents (SEMS) are widely used for the palliative treatment of malignant gastrointestinal obstruction. Our aim was to evaluate the evidence comparing covered and bare SEMS in the digestive tract using meta-analytical techniques. A literature search was performed using PubMed, Cochrane Library, and Embase databases for comparative studies assessing the two types of stents. The primary outcomes of interest were stent patency and patient survival; second outcomes included technical success, clinical success, tumor ingrowth, tumor overgrowth, and stent migration. A random-effects model was conducted. Pooled analysis was done separately based on the different segments of the digestive tract. Eleven studies (8 randomized controlled trials and 3 prospective cohort studies) including a total of 1376 patients were identified. Covered SEMS were equivalent to bare SEMS in terms of technical success, clinical success, stent patency (gastroduodenal obstruction: HR =0.87, 95% CI 0.53-1.42; colorectal obstruction: HR =0.89, 95% CI 0.18-4.45; biliary obstruction: HR =0.73, 95% CI 0.41-1.32) and survival rates (esophageal obstruction: HR =1.80, 95% CI 0.73-4.44; gastroduodenal obstruction: HR =0.83, 95% CI 0.55-1.26; biliary obstruction: HR =0.99, 95% CI 0.77-1.28), although bare stents were more prone to tumor ingrowth (esophageal obstruction: RR =0.10, 95% CI 0.01-0.77; gastroduodenal obstruction: RR =0.12, 95% CI 0.03-0.55; colorectal obstruction: RR =0.21, 95% CI 0.06-0.70; biliary obstruction: RR =0.21, 95% CI 0.06-0.69), whereas covered stents had the higher risk of stent migration (gastroduodenal obstruction: RR =5.01, 95% CI 1.53-16.43; colorectal obstruction: RR =11.70, 95% CI 2.84-48.27; biliary obstruction: RR =8.11, 95% CI 1.47-44.76) and tumor overgrowth (biliary obstruction: RR =2.03, 95% CI 1.08-3.78). Both covered and bare SEMS are comparable in efficacy for the palliative treatment of malignant obstruction in the digestive tract. Each type of

  10. Clinical outcomes between different stent designs with the same polymer and drug: comparison between the Taxus Express and Taxus Liberte stents.

    Science.gov (United States)

    Son, Jang-Won; Kim, Ung; Park, Jong-Seon; Kim, Young-Jo; Jang, Jae-Sik; Yang, Tae-Hyun; Kim, Dong-Soo; Kim, Dong-Kie; Seol, Sang-Hoon; Kim, Doo-Il; Nam, Chang-Wook; Hur, Seung-Ho; Kim, Kwon-Bae

    2013-01-01

    The Taxus Liberte stent (Boston Scientific Co.) evolved from the Taxus Express stent, with enhanced stent deliverability and uniform drug delivery. This study was designed to compare angiographic and clinical outcomes in real-world practice between the Taxus Liberte and Taxus Express stents. Between 2006 and 2008, 240 patients receiving the Taxus Liberte stent at three centers were registered and compared to historical control patients who had received the Taxus Express stent (n = 272). After propensity score matching, 173 patients treated with the Taxus Liberte stent and the same number of patients treated with the Taxus Express stent were selected. The primary outcome was a composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), ischemia driven target vessel revascularization (TVR), and stent thrombosis (ST) at 1 year. An additional angiographic assessment was conducted at 9 to 12 months. The study showed no significant difference between the Taxus Express and Taxus Liberte stents (death, 1.73% vs. 2.31%, p = 1.000; MI, 0% vs. 1.73%, p = 0.2478; TVR, 2.31% vs. 1.16%, p = 0.6848; and ST, 0% vs. 1.16%, p = 0.4986). The total MACE rate at 1 year did not differ between the groups (4.05% in Taxus Express vs. 4.05% in Taxus Liberte, p = 1.000). In addition, the binary restenosis rate did not differ (2.25% in Taxus Express vs. 1.80% in Taxus Liberte, p = 0.6848). In real-world experience with the two Taxus stent designs, both stents showed similarly good clinical and angiographic outcomes at 1 year. A long-term follow-up study is warranted.

  11. An ovine in vivo framework for tracheobronchial stent analysis.

    Science.gov (United States)

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Shea, Mary B; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2017-10-01

    Tracheobronchial stents are most commonly used to restore patency to airways stenosed by tumour growth. Currently all tracheobronchial stents are associated with complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. The present work develops a computational framework to evaluate tracheobronchial stent designs in vivo. Pressurised computed tomography is used to create a biomechanical lung model which takes into account the in vivo stress state, global lung deformation and local loading from pressure variation. Stent interaction with the airway is then evaluated for a number of loading conditions including normal breathing, coughing and ventilation. Results of the analysis indicate that three of the major complications associated with tracheobronchial stents can potentially be analysed with this framework, which can be readily applied to the human case. Airway deformation caused by lung motion is shown to have a significant effect on stent mechanical performance, including implications for stent migration, granulation formation and stent fracture.

  12. First-in-man study of simvastatin-eluting stent in de novo coronary lesions: the SIMVASTENT study.

    Science.gov (United States)

    Zago, Alexandre C; Matte, Bruno S; Reginato, Luciana; Iturry-Yamamoto, Germán; Krepsky, Ana; Bergoli, Luiz Carlos C; Balvedi, Julise; Raudales, José C; Saadi, Eduardo K; Zago, Alcides J

    2012-01-01

    Statins have anti-inflammatory and antiproliferative properties irrespective of their cholesterol-lowering effects. The aim of the present study was to evaluate a simvastatin-eluting stent (SimvES) in the treatment of de novo coronary lesions. Forty-two patients with de novo coronary artery lesions were assigned to SimvES, bare-metal stent (BMS) or everolimus-eluting stent (EES) implantation followed by intravascular ultrasound (IVUS) for neointimal quantitative analysis. Six months later, quantitative coronary angiography (QCA) and IVUS were repeated. QCA showed no binary restenosis, a mean in-stent late loss of 1.05 ± 0.25 mm (BMS, 1.12 ± 0.48 mm; EES, 0.20 ± 0.16 mm) and a diameter stenosis of 33.5 ± 7.1% (BMS, 35.5 ± 15.30%; EES, 7.2 ± 3.12%). Control IVUS showed a mean in-stent obstruction of 18.3 ± 9.4% (BMS, 32.8 ± 19.1%; EES, 9.8 ± 2.4%) and a neointimal volume index of 1.58 ± 0.75 mm(3)/mm (BMS, 2.93 ± 1.76 mm(3)/mm; EES, 0.80 ± 0.16 mm(3)/mm). Thrombus, late incomplete apposition and major adverse cardiac events were not observed. In this sample of patients with de novo coronary lesions, the use of a SimvES was not related to major adverse cardiac events, but it was associated with a higher level of neointimal proliferation than expected.

  13. Brachytherapy on restenosis. {sup 32}P radioisotope in animal model

    Energy Technology Data Exchange (ETDEWEB)

    Bergoc, R.; Rivera, E.; Cocca, C.; Martin, G.; Cricco, G. [Buenos Aires Univ. (Argentina). School of Pharmacy and Biochemistry; Croci, M.; Guzman, L.

    2000-05-01

    Despite a notorious decline in age-adjusted death rates for cardiovascular pathologies, coronary artery disease still remains as the main cause of mortality above the age of 40 in men and 60 in women. More than 25% of death in persons over the age of 35 are due to coronary disease. In about 50% of men and 30% of women, the first manifestation of the disease is an acute myocardial infarction and 10% a sudden cardiac death. In Argentina it is estimated that in 1998 about 100.000-115.000 people suffered as first manifestation of coronary illness a myocardial acute infarct. Angioplasty has an important and well established site in the treatment of the coronary illness and restenosis represents the principal complication of this method for myocardial re-vascularization. About a 35-40% of treated arteries present restenosis within the first six month the intervention with the concomitant need of re-interventions, re-hospitalizations, by-pass surgery, work discontinuity and the high cost for the health system. A number of drugs were tested as anti-restenosis: anticoagulants, aspirin, antispasmodics and lipid-lowering agents but none was clearly efficient; also, experimental studies in which intravascular irradiation with different source types and energies, radiation doses and doses rate to prevent restenosis was utilized; however, there is no consensus in many aspects of this intravascular brachytherapy. The first step in this work was to induce the experimental model in rabbits. Afterwards, by means of the balloon methodology and stent implantation, brachytherapy experiments were carried out to evaluate the biological effect on different layers of arteries, with different Doses using a beta particle emitting radioisotope ({sup 32}P). The arteriosclerotic lesions were induced in New Zealand rabbits through the administration of a diet with high cholesterol content. Angioplastic interventions on femoral arteries were done with balloon methodology and controlled by

  14. Indications and applications of arterial stents for stroke prevention in atherosclerotic intracranial stenosis.

    Science.gov (United States)

    Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L

    2010-01-01

    Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.

  15. Carotid angioplasty and stenting for symptomatic carotid kinking combined with stenosis

    Directory of Open Access Journals (Sweden)

    JIANG Xue-li

    2013-03-01

    Full Text Available Background Carotid endarterectomy (CEA is currently the preferred treatment for severe carotid kinking and stenosis. Kinking is generally believed to be a relative contraindication for endovascular stent placement. This article aims to study the necessity, feasibility and security of carotid angioplasty and stenting (CAS for symptomatic carotid kinking combined with stenosis, and summarize clinical experience of this disease according to therapeutic results. Methods Twenty-two cases with symptomatic carotid kinking and high-grade stenosis demonstrated by digital subtraction angiography (DSA were performed CAS. Their clinical manifestations, imaging features, procedure safety and follow-up data were collected and retrospectively analyzed. All patients understood CEA and voluntarily received CAS. Results Twenty-two cases with carotid kinking and stenosis were all successfully performed CAS (the success rate was 100% without stent-related disability or mortality. Twenty-four self-expandable stents were implanted. The mean degree of stenosis was reduced from 85.63%before stenting to 11.25% after stenting and the angles of kinking were improved from 120° (Metz' category. During the period of hospitalization, no transient ischemic attack (TIA or cerebral infarction occurred, and the clinical symptoms and signs of ischemia, such as dizziness and headache, were improved or disappeared. Besides, no permenant complications or deaths happened. All cases were followed up from 6 to 72 months, among whom 1 patient experienced contralateral carotid TIA, and 2 patients experienced ipsilateral carotid TIA (one indicated aspirin resistance in platelet aggregation test and the other showed restenosis in DSA. Computed tomography angiography (CTA of 10 patients and Duplex scan of 7 patients during the follow-up demonstrated carotid in good morphology and fluent blood flow, without kinking or restenosis. Conclusion CAS is a feasible and safe therapeutic method and

  16. Bioresorbable polymer coated drug eluting stent: a model study.

    Science.gov (United States)

    Rossi, Filippo; Casalini, Tommaso; Raffa, Edoardo; Masi, Maurizio; Perale, Giuseppe

    2012-07-02

    In drug eluting stent technologies, an increased demand for better control, higher reliability, and enhanced performances of drug delivery systems emerged in the last years and thus offered the opportunity to introduce model-based approaches aimed to overcome the remarkable limits of trial-and-error methods. In this context a mathematical model was studied, based on detailed conservation equations and taking into account the main physical-chemical mechanisms involved in polymeric coating degradation, drug release, and restenosis inhibition. It allowed highlighting the interdependence between factors affecting each of these phenomena and, in particular, the influence of stent design parameters on drug antirestenotic efficacy. Therefore, the here-proposed model is aimed to simulate the diffusional release, for both in vitro and the in vivo conditions: results were verified against various literature data, confirming the reliability of the parameter estimation procedure. The hierarchical structure of this model also allows easily modifying the set of equations describing restenosis evolution to enhance model reliability and taking advantage of the deep understanding of physiological mechanisms governing the different stages of smooth muscle cell growth and proliferation. In addition, thanks to its simplicity and to the very low system requirements and central processing unit (CPU) time, our model allows obtaining immediate views of system behavior.

  17. Beyond Oncogenesis: The Role of S-Phase Kinase-Associated Protein-2 (SKP2 In Vascular Restenosis

    Directory of Open Access Journals (Sweden)

    Yih-Jer Wu

    2008-12-01

    Full Text Available The clinical benefits of percutaneous coronary intervention, the most prevalent procedure nowadays for the treatment of symptomatic coronary artery disease, are frequently offset by the occurrence of vascular restenosis. Although the introduction of drug-eluting stents has significantly reduced restenotic rates, the rare, but potentially fatal, delayed thrombosis remains a clinical threat. Further refinement of the drug-eluting stent based on a better understanding of cell cycle regulation between the vascular smooth muscle cell (VSMC and endothelial cell (EC is required. In this review, we discuss the role of S-phase kinase-associated protein-2 (Skp2, previously known as an oncoprotein, in the regulation of VSMC proliferation and its signaling axis. The currently available evidence suggests that the Rac1-Skp2-p27Kip1 signaling axis acts as a common final pathway for many factors that regulate VSMC proliferation, such as growth factors, extracellular matrices and cyclic nucleotides. Importantly, although EC proliferation is also shown to be regulated by the same axis, cAMP seems to regulate this axis differentially between VSMC and EC, rendering the underlying mechanism of this differential regulation a promising target for the development of a new generation of drug-eluting stent.

  18. Edge Stenosis After Covered Stenting for Long Superficial Femoral Artery Occlusive Disease: Risk Factor Analysis and Prevention With Drug-Coated Balloon Angioplasty.

    Science.gov (United States)

    Lin, Ting-Chao; Huang, Chun-Yang; Chen, Po-Lin; Lee, Chiu-Yang; Shih, Chun-Che; Chen, I-Ming

    2018-06-01

    To report a retrospective analysis of risk factors for edge restenosis after Viabahn stent-graft treatment of superficial femoral artery (SFA) occlusive disease and determine any protective effect of drug-coated balloons (DCBs) used at the time of stent-graft implantation. Between October 2011 and July 2016, 110 patients (mean age 73.3±7.6 years; 78 men) were treated with the Viabahn stent-graft for long SFA occlusions. Thirty-eight (34.5%) patients had DCB reinforcement at the distal edge of the stent-graft. For analysis, the population was divided into groups of no edge stenosis patients (n=88; mean lesion length 22.4±4.2 cm) and edge stenosis patients (n=22; mean lesion length 23.5±5.7 cm). The clinical outcomes, ankle-brachial indices, computed tomography angiography findings, and patency were compared at a minimum of 12 months. Logistic regression analysis was employed to determine risk factors for edge stenosis; the results are presented as the odds ratio (OR) and 95% confidence interval. No differences in clinical or procedural characteristics were identified except the higher incidence of diabetes (p=0.008) and greater need for retrograde access (p=0.033) in the edge stenosis group. DCB reinforcement reduced the incidence of edge stenosis (p=0.021) and target lesion revascularization (TLR; p=0.010) and resulted in a significantly higher 1-year primary patency rate (92.1% vs 76.4%, p=0.042). However, multivariate analysis revealed only poor distal runoff (OR 0.31, 95% CI 0.11 to 0.83, p=0.020) as a predictor of edge stenosis. The risk of edge stenosis after Viabahn implantation was higher in patients with poor distal runoff. DCB reinforcement over the distal edge reduced edge stenosis, decreased 1-year TLR, and improved 1-year primary patency.

  19. The therapeutic effects and experience of tracheal stent implantation in managing severe tracheal stenosis

    International Nuclear Information System (INIS)

    Lv Weifu; Zhang Xingming; Zhang Xuebing; Wang Weiyu; Hou Changlong

    2006-01-01

    Objective: To evaluate the therapeutic effects and experience of the tracheal stent implantation for the management of severe tracheal stenosis. Materials: Thirteen patients with severe tracheal stenosis of various causes underwent high kilovoltage radiography and computed tomography for evaluating the site, form and extent of the stenosis including 10 at the trachea, 1 at the right main bronchus and 2 at left main bronchus. The C2 catheter assisted with ultra-slipping guide wire was inserted into the trachea under fluoroscopy and then a replaced high shoring guide wire was pushed through the stenotic segment and retained the stent. Results: All stents were implanted successfully with successful rate 100% together with dyspnoeic improvements. The mean survival time was 6.2 months for patients with malignant neoplasm. One patient with benign tracheal stenosis has been followed-up for 5 years without restenosis. Conclusions: The tracheal stent implantation is an effective means for severe tracheal stenosis. (authors)

  20. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-01-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746

  1. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance.

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-05-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.

  2. Re-examining minimal luminal diameter relocation and quantitative coronary angiography - Intravascular ultrasound correlations in stented saphenous vein grafts: Methodological insights from the randomised RRISC trial

    NARCIS (Netherlands)

    O. Semeraro (Oscar); P. Agostoni (Pierfrancesco); S. Verheye (Stefan); G.J.J. van Langenhove (Glenn); P.A. van den Heuvel (Paul); C. Convens (Carl); F. van den Branden (Frank); N. Bruining (Nico); P. Vermeersch (Paul)

    2009-01-01

    textabstractAims: Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. Methods and results: Using quantitative coronary angiography (QCA)

  3. Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers

    Directory of Open Access Journals (Sweden)

    Brendan Doyle

    2009-11-01

    Full Text Available Brendan Doyle, David R Holmes JrDivision of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota, USAAbstract: The success of drug-eluting stents in preventing restenosis has shifted the focus of new stent development toward enhancing long term safety and efficacy of these devices, while simultaneously eliminating the need for indefinite dual antiplatelet therapy. A technical advance fulfilling these aims would hold tremendous potential to reduce morbidity, mortality and economic costs associated with the percutaneous treatment of coronary artery disease. An attractive approach is the use of bioabsorbable stent designs. These may include stents with different bioabsorbable drugs, bioabsorbable polymers or even bioabsorbable metallic backbones. A device that could achieve excellent acute and long-term results, but disappear completely within months (thereby avoiding the need for prolonged dual antiplatelet therapy, would be a tremendous advance. Too good to be true? We explore here the scientific rationale and prospects for success with this exciting concept.Keywords: percutaneous coronary intervention, biodegradable, bioabsorbable, polymer, stent

  4. Angioplasty and stent placement in the treatment of radiation-induced arterial injury

    International Nuclear Information System (INIS)

    Liu Pengcheng; Pierre, P.; Philippe, O.; Danial, C.; Jean-Paul, B.; Cyril, B.; Jean-Pierre, C.; Denis, K.; Helve, R.; Francis, J.

    1999-01-01

    Objective: Evaluation of therapeutic efficacy and longterm patency of angioplasty and stent for the treatment of radiation induced arterial disease. Methods: PTA was attempted in 18 arterial lesions following irradiation in 14 patients. Thirteen stents were placed in 8 patients to treat occlusion (n = 3), aneurysm (n = 1), residual stenosis (n =2), multiple stenoses (n = 1), and delayed restenosis after previous balloon angioplasty (n = 1). The stents were readily visualized and patency of the stent and the target artery determined with Doppler US and (or) CT in all patients. Results: Interventional procedure was successful in 14 patients of which 8 underwent stent placement for their arterial lesions. Eleven of these patients demonstrated primary patency with relief of clinical symptoms with a mean follow-up of 2 years (range, 8 months -60 months). Clinical improvement was noted for the other patients. Eleven patients underwent PTA once or twice. One patient had PTA four times and three stents were installed, two of which were in the area of the aortic bifurcation, and one in the celiac trunk. another patient also had PTA four times and two stents were placed in the superior mesenteric artery. A stent was implanted in one patient because of PTA induced dissection and occlusion, and the arterial lesion was considered to be cured clinically after a follow-up of 5 years. Conclusions: The results suggested that PTA with single or multiple techniques may be effective immediately in the treatment of arterial lesions caused by radiation and can be considered the first therapeutic option in these cases

  5. Predictive value study of serum STIM1 and Adropin contents in cardiovascular events and restenosis after PCI operation

    Directory of Open Access Journals (Sweden)

    Qiu-Wei Lin

    2016-02-01

    Full Text Available Objective: To study the predictive value of serum STIM1 and Adropin contents in cardiovascular events and restenosis after PCI operation. Methods: Single coronary artery lesion patients receiving percutaneous coronary intervention in our hospital from May 2014 to January 2015 were selected for study, 45 cases of patients with in-stent restenosis 6 months after PCI operation more than 50% were enrolled in ISR group, 85 cases of patients with instent restenosis no more than 50% were enrolled in NISR group, and then serum STIM1, Adropin and NO contents as well as endothelial progenitor cell content and endothelial microparticle number in peripheral blood of two groups were detected. Results: Serum STIM1 content of ISR group was significantly higher than that of NISR group and STIM1 content was positively correlated with lumen stenosis degree, and serum Adropin content of ISR group was significantly lower than that of NISR group and Adropin content was negatively correlated with lumen stenosis degree; endothelial progenitor cell content in peripheral blood and serum NO content of ISR group were less than those of NISR group, and endothelial microparticle number in peripheral blood was more than that of NISR group; serum STIM1 content was positively correlated with endothelial microparticle number in peripheral blood and negatively correlated with endothelial progenitor cell content in peripheral blood, and serum Adropin content was negatively correlated with endothelial microparticle number in peripheral blood and positively correlated with serum NO content. Conclusion: Serum STIM1 content increase and Adropin content decrease are related to the occurrence of cardiovascular events and restenosis after PCI operation, and the two molecules mainly affect endothelial cell function and endothelial progenitor cell homing.

  6. Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents.

    Science.gov (United States)

    Choi, Woong Gil; Kim, Soo Hyun; Yoon, Hyung Seok; Lee, Eun Joo; Kim, Dong Woon

    2015-01-01

    Although drug-eluting stents (DESs) effectively reduce restenosis following percutaneous coronary intervention (PCI), they also delay re-endothelialization and impair microvascular function, resulting in adverse clinical outcomes. Endothelial progenitor cell (EPC) capturing stents, by providing a functional endothelial layer on the stent, have beneficial effects on microvascular function. However, data on coronary microvascular function in patients with EPC stents versus DESs are lacking. Seventy-four patients who previously underwent PCI were enrolled in this study. Microvascular function was evaluated 6 months after PCI based on the index of microvascular resistance (IMR) and the coronary flow reserve (CFR). IMR was calculated as the ratio of the mean distal coronary pressure at maximal hyperemia to the inverse of the hyperemic mean transit time (hTmn). The CFR was calculated by dividing the hTmn by the baseline mean transit time. Twenty-one patients (age, 67.2 ± 9.6 years; male:female, 15:6) with an EPC stent and 53 patients (age, 61.5 ± 14.7 years; male:female, 40:13) with second-generation DESs were included in the study. There were no significant differences in the baseline clinical and angiographic characteristics of the two groups. Angiography performed 6 months postoperatively did not show significant differences in their CFR values. However, patients with the EPC stent had a significantly lower IMR than patients with second-generation DESs (median, 25.5 [interquartile range, 12.85 to 28.18] vs. 29.0 [interquartile range, 15.42 to 39.23]; p = 0.043). Microvascular dysfunction was significantly improved after 6 months in patients with EPC stents compared to those with DESs. The complete re-endothelialization achieved with the EPC stent may provide clinical benefits over DESs, especially in patients with microvascular dysfunction.

  7. A Survival Analysis of Patients with Malignant Biliary Strictures Treated by Percutaneous Metallic Stenting

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Ptochis, Nikolaos; Panagiotou, Irene; Malagari, Katerina; Tzavara, Chara; Kelekis, Dimitrios

    2007-01-01

    Background. Percutaneous metal stenting is an accepted palliative treatment for malignant biliary obstruction. Nevertheless, factors predicting survival are not known. Methods. Seventy-six patients with inoperable malignant biliary obstruction were treated with percutaneous placement of metallic stents. Twenty patients had non-hilar lesions. Fifty-six patients had hilar lesions classified as Bismuth type I (n = 15 patients), type II (n = 26), type III (n = 12), or type IV (n = 3 patients). Technical and clinical success rates, complications, and long-term outcome were recorded. Clinical success rates, patency, and survival rates were compared in patients treated with complete (n = 41) versus partial (n = 35) liver parenchyma drainage. Survival was calculated and analyzed for potential predictors such as the tumor type, the extent of the disease, the level of obstruction, and the post-intervention bilirubin levels. Results. Stenting was technically successful in all patients (unilateral drainage in 70 patients, bilateral drainage in 6 patients) with an overall significant reduction of the post-intervention bilirubin levels (p < 0.001), resulting in a clinical success rate of 97.3%. Clinical success rates were similar in patients treated with whole-liver drainage versus partial liver drainage. Minor and major complications occurred in 8% and 15% of patients, respectively. Mean overall primary stent patency was 120 days, while the restenosis rate was 12%. Mean overall secondary stent patency was 242.2 days. Patency rates were similar in patients with complete versus partial liver drainage. Mean overall survival was 142.3 days. Survival was similar in the complete and partial drainage groups. The post-intervention serum bilirubin level was an independent predictor of survival (p < 0.001). A cut-off point in post-stenting bilirubin levels of 4 mg/dl dichotomized patients with good versus poor prognosis. Patient age and Bismuth IV lesions were also independent predictors

  8. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  9. TOKYO criteria 2014 for transpapillary biliary stenting.

    Science.gov (United States)

    Isayama, Hiroyuki; Hamada, Tsuyoshi; Yasuda, Ichiro; Itoi, Takao; Ryozawa, Shomei; Nakai, Yousuke; Kogure, Hirofumi; Koike, Kazuhiko

    2015-01-01

    It is difficult to carry out meta-analyses or to compare the results of different studies of biliary stents because there is no uniform evaluation method. Therefore, a standardized reporting system is required. We propose a new standardized system for reporting on biliary stents, the 'TOKYO criteria 2014', based on a consensus among Japanese pancreatobiliary endoscopists. Instead of stent occlusion, we use recurrent biliary obstruction, which includes occlusion and migration. The time to recurrent biliary obstruction was estimated using Kaplan-Meier analysis with the log-rank test. We can evaluate both plastic and self-expandable metallic stents (uncovered and covered). We also propose specification of the cause of recurrent biliary obstruction, identification of complications other than recurrent biliary obstruction, indication of severity, measures of technical and clinical success, and a standard for clinical care. Most importantly, the TOKYO criteria 2014 allow comparison of biliary stent quality across studies. Because blocked stents can be drained not only using transpapillary techniques but also by an endoscopic ultrasonography-guided transmural procedure, we should devise an evaluation method that includes transmural stenting in the near future. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  10. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  11. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  12. A novel stent inflation protocol improves long-term outcomes compared with rapid inflation/deflation deployment method.

    Science.gov (United States)

    Vallurupalli, Srikanth; Kasula, Srikanth; Kumar Agarwal, Shiv; Pothineni, Naga Venkata K; Abualsuod, Amjad; Hakeem, Abdul; Ahmed, Zubair; Uretsky, Barry F

    2017-08-01

    High-pressure inflation for coronary stent deployment is universally performed. However, the duration of inflation is variable and does not take into account differences in lesion compliance. We developed a standardized "pressure optimization protocol" (POP) using inflation pressure stability rather than an arbitrary inflation time or angiographic balloon appearance for stent deployment. Whether this approach improves long-term outcomes is unknown. 792 patients who underwent PCI using either rapid inflation/deflation (n = 376) or POP (n = 416) between January 2009 and March 2014 were included. Exclusion criteria included PCI for acute myocardial infarction, in-stent restenosis, chronic total occlusion, left main, and saphenous vein graft lesions. Primary endpoint was target vessel failure [TVF = combined end point of target vessel revascularization (TVR), myocardial infarction, and cardiac death]. Outcomes were analyzed in the entire cohort and in a propensity analysis. Stent implantation using POP with a median follow-up of 1317 days was associated with lower TVF compared with rapid inflation/deflation (10.1 vs. 17.8%, P inflation/deflation (10 vs. 18%, P < 0.0001). Stent deployment using POP led to reduced TVF compared to rapid I/D. These results recommend this method to improve long-term outcomes. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Optimized intravenous flat detector CT for non-invasive visualization of intracranial stents: first results

    International Nuclear Information System (INIS)

    Struffert, Tobias; Kloska, Stephan; Engelhorn, Tobias; Ott, Sabine; Doelken, Marc; Saake, Marc; Doerfler, Arnd; Deuerling-Zheng, Yu.; Koehrmann, Martin

    2011-01-01

    As stents for treating intracranial atherosclerotic stenosis may develop in-stent re-stenosis (ISR) in up to 30%, follow-up imaging is mandatory. Residual stenosis (RS) is not rare. We evaluated an optimised Flat Detector CT protocol with intravenous contrast material application (i.v. FD-CTA) for non-invasive follow-up. In 12 patients with intracranial stents, follow-up imaging was performed using i.v. FD-CTA. MPR, subtracted MIP and VRT reconstructions were used to correlate to intra-arterial angiography (DSA). Two neuroradiologists evaluated the images in anonymous consensus reading and calculated the ISR or RS. Correlation coefficients and a Wilcoxon test were used for statistical analysis. In 4 patients, no stenosis was detected. In 6 patients RS and in two cases ISR by intima hyperplasia perfectly visible on MPR reconstructions of i.v. FD-CTA were detected. Wilcoxon's test showed no significant differences between the methods (p > 0.05). We found a high correlation with coefficients of the pairs DSA/ FD-CT MIP r = 0.91, DSA/ FD-CT MPR r = 0.82 and FD-CT MIP/ FD-CT MPR r = 0.8. Intravenous FD-CTA could clearly visualise the stent and the lumen, allowing ISR or RS to be recognised. FD-CTA provides a non-invasive depiction of intracranial stents and might replace DSA for non-invasive follow-up imaging. (orig.)

  14. Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves

    International Nuclear Information System (INIS)

    Yamazaki, Tadashi; Suzuki, Jun-ichi; Shimamoto, Ryoichi; Tsuji, Taeko; Ohmoto-Sekine, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Komatsu, Shuhei; Akahane, Masaaki; Ohtomo, Kuni

    2008-01-01

    Purpose: Hounsfield CT values across coronary CT angiograms constitute CT value-spatial profile curves. These CT profile curves are independent of window settings, and therefore, parameters derived from the curves can be used for objective anatomic analyses. Applicability of parameters derived from the curves to quantification of coronary in-stent patency has not yet been evaluated. Methods: Twenty-five CT value-spatial profile curves were delineated from 10 consecutive coronary stents to test correlation between the curve derived parameter (i.e., the minimum extreme value normalized by dividing by the maximum value of the curves obtained at neighboring outside of stents) and three intravascular ultrasound (IVUS) parameters. Results: Correlation coefficients between normalized minimum extreme value of CT value-spatial profile curves and three IVUS parameters (such as patent cross-sectional in-stent area, the percentage of patent cross-sectional in-stent area, and coronary artery intra-stent diameter) were 0.65 (p < 0.01), 0.44 (p < 0.05) and 0.51 (p < 0.05), respectively. Conclusions: CT parameters defined on Hounsfield CT value-spatial profile curves correlated significantly with IVUS parameters for quantitative coronary in-stent patency. A new approach with CT coronary angiography is therefore indicated for the noninvasive assessment of in-stent re-stenosis

  15. Surface engineering of cardiovascular stent with endothelial cell selectivity for in vivo re-endothelialisation.

    Science.gov (United States)

    Wei, Yu; Ji, Ying; Xiao, Lin-Lin; Lin, Quan-kui; Xu, Jian-ping; Ren, Ke-feng; Ji, Jian

    2013-04-01

    The in vivo endothelialisation of materials provides a promising strategy for the rapid re-endothelialisation of a cardiovascular implantation. Although many studies have focused on improving the rapid endothelialisation through the immobilisation of bioactive molecules, it should be noted that the endothelial cells (ECs) will compete with other cell types in vivo. Thus, the efforts to partially enhance the EC growth without considering the cell competition might be misleading and meaningless in vivo. In this study, we demonstrated that the competitive growth of human umbilical vein endothelial cells (HUVECs) over human aortic smooth muscle cells (HASMCs) could be increased through the synergic action of the nonspecific resistance to phosphorylcholine and the specific recognition of the REDV peptide. Further in vivo data indicate that the competitive ability of ECs over SMCs, instead of the number of ECs, is a significantly more important criterion for the development of a pure endothelial layer in vivo and thus the attainment of a better anti-restenosis effect. Consequently, the surface tailoring of a stent to obtain high endothelial cell selectivity is likely an effective design criterion for in situ endothelialisation and a possible future solution for the problem of in-stent restenosis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Long-Term Safety of Drug-Eluting and Bare-Metal Stents

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Benedetto, Umberto; Biondi-Zoccai, Giuseppe

    2015-01-01

    BACKGROUND: Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety....... RESULTS: Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial...... infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target...

  17. Efficacy of α-blocker in improving ureteral stent-related symptoms: a meta-analysis of both direct and indirect comparison

    Directory of Open Access Journals (Sweden)

    He F

    2016-05-01

    Full Text Available Feng He, Li-bo Man, Gui-zhong Li, Ning Liu Department of Urinary Surgery, Beijing Jishuitan Hospital, Beijing, People’s Republic of China Objective: To critically evaluate the efficacy of an α-blocker in improving ureteral-stent-related symptoms and preliminarily investigate the difference between different types of α-blockers. Methods: Relevant randomized controlled trials were identified through searching PubMed, the Cochrane Library, Embase, and other sources. After quality assessment and data abstraction, direct comparison based on the Ureteral Stent-related Symptom Questionnaire (USSQ between α-blockers and control was performed by RevMan 5.3. Indirect comparison between different types of α-blockers was performed by ITC 1.0. Sensitive and subgroup analyses were used to handle important clinical factors. Results: Sixteen randomized controlled trials containing 1,489 cases were included. Compared with control, α-blockers significantly reduced the overall urinary symptom, pain index, general health index, and scores related to sexual matters, while no significant difference was found in work performance and additional problem scores. Subgroup analysis showed that the duration of stent insertion, patient’s age, stent size, and the type of α-blocker had the potential to influence the outcomes. Through indirect comparison, we found alfuzosin and terazosin to be better than tamsulosin in pain relief and general health improvement. Conclusion: α-Blocker was effective in treating ureteral stent-related symptoms, as it improved the major indexes of USSQ post-insertion or post-removal. Alfuzosin and terazosin seemed to be better than tamsulosin, which needs further verification because of the lack of direct comparison currently. Keywords: α-blocker, tamsulosin, alfuzosin, terazosin, ureteral stent-related discomfort

  18. Computational design analysis for deployment of cardiovascular stents

    International Nuclear Information System (INIS)

    Tammareddi, Sriram; Sun Guangyong; Li Qing

    2010-01-01

    Cardiovascular disease has become a major global healthcare problem. As one of the relatively new medical devices, stents offer a minimally-invasive surgical strategy to improve the quality of life for numerous cardiovascular disease patients. One of the key associative issues has been to understand the effect of stent structures on its deployment behaviour. This paper aims to develop a computational model for exploring the biomechanical responses to the change in stent geometrical parameters, namely the strut thickness and cross-link width of the Palmaz-Schatz stent. Explicit 3D dynamic finite element analysis was carried out to explore the sensitivity of these geometrical parameters on deployment performance, such as dog-boning, fore-shortening, and stent deformation over the load cycle. It has been found that an increase in stent thickness causes a sizeable rise in the load required to deform the stent to its target diameter, whilst reducing maximum dog-boning in the stent. An increase in the cross-link width showed that no change in the load is required to deform the stent to its target diameter, and there is no apparent correlation with dog-boning but an increased fore-shortening with increasing cross-link width. The computational modelling and analysis presented herein proves an effective way to refine or optimise the design of stent structures.

  19. Predicting late restenosis after coronary angioplasty by very early (12 to 24 h) thallium-201 scintigraphy: Implications with regard to mechanisms of late coronary restenosis

    International Nuclear Information System (INIS)

    Hardoff, R.; Shefer, A.; Gips, S.; Merdler, A.; Flugelman, M.Y.; Halon, D.A.; Lewis, B.S.

    1990-01-01

    To examine whether late coronary restenosis may be predicted by abnormalities of myocardial perfusion in the early hours after successful percutaneous transluminal coronary angioplasty and to study in greater detail the mechanisms involved in the development of late coronary restenosis after angioplasty, a prospective study was undertaken in 90 consecutive patients. Thallium-201 scintigrams were recorded at rest and during the stress of atrial pacing, 12 to 24 h after angioplasty, and the results were related to the findings at angiography in 70 patients undergoing late cardiac catheterization. A reversible thallium-201 perfusion defect was found in 39 (38%) of 104 myocardial regions supplied by the dilated coronary vessel and identified a subset of patients at high risk of late (6 to 12 months) angiographic restenosis (sensitivity 77%, specificity 67%). In contrast, late coronary restenosis developed in only 7 (11%) of 65 vessels and in 5 (14%) of 37 patients with a nonischemic thallium-201 scintigram on day 1 (p less than 0.005). Multivariate logistic regression analysis of 14 possible preangioplasty and periangioplasty clinical and angiographic variables selected reversible perfusion defect on the thallium-201 scintigram on day 1 (p = 0.016) and immediate postangioplasty residual coronary narrowing (p = 0.004) as significant independent predictors of late restenosis, with younger patient age as an additional less powerful predictor (p less than 0.05). The findings have important implications regarding the pathogenesis of late coronary restenosis in patients undergoing successful angioplasty and they imply that in the majority of these patients pathophysiologic events in the early minutes and hours after angioplasty may determine the development of late restenosis

  20. Biodegradable biliary stent implantation in the treatment of benign bilioplastic-refractory biliary strictures: preliminary experience.

    Science.gov (United States)

    Mauri, Giovanni; Michelozzi, Caterina; Melchiorre, Fabio; Poretti, Dario; Tramarin, Marco; Pedicini, Vittorio; Solbiati, Luigi; Cornalba, Gianpaolo; Sconfienza, Luca Maria

    2013-12-01

    To evaluate feasibility, safety, and outcome of patients treated with biodegradable biliary stents for benign biliary stenosis refractory to other treatments. Between March 2011 and September 2012, ten patients (seven men, three women; age 59 ± 7 years) with recurrent cholangitis due to postsurgical biliary stricture, previous multiple unsuccessful (two to five) bilioplasties, and unsuitability for surgical/endoscopic repair underwent percutaneous implantation of a biodegradable biliary stent. Patients were followed-up clinically and with ultrasound at 1, 3 and 6 months, and then at 6-month intervals. Stent implantation was always feasible. No immediate major or minor complications occurred. In all patients, 48-h cholangiographic control demonstrated optimal stent positioning and stenosis resolution. In a median follow-up time of 16.5 months (25th-75th percentiles = 11-20.25 months) no further invasive treatment was needed. Three patients experienced transient episodes of cholangitis. Neither re-stenosis nor dilatation of the biliary tree was documented during follow-up. No stent was visible at the 6-month follow-up. Percutaneous placement of biodegradable biliary stents represents a new option in treating benign biliary stenoses refractory to treatment with bilioplasty. This technique seems to be feasible, effective and free from major complications. Further investigations are warranted to confirm our preliminary results.

  1. Atherectomy in complex infrainguinal lesions: a review.

    Science.gov (United States)

    Engelberger, S; van den Berg, J C

    2015-02-01

    In the femoropopliteal segment, endovascular revascularization techniques have gained the role as a first line treatment strategy. Nitinol stent placement has improved the short- and mid-term primary patency rates in most lesion types and is therefore widely applied. Stenting has several shortcomings as in-stent restenosis, stent fractures and foreign material being left behind in the vessel. The concept of atherectomy is plaque debulking. This results in a potential reduction of inflation pressure requirements in angioplasty. Stent placement and consecutive in-stent restenosis may be avoided. In this non systematic literature review, the performance of different atherectomy techniques, such as direct atherectomy, orbital atherectomy, laser debulking and rotational atherectomy in the treatment of complex femoropopliteal lesions, including long lesions, moderately to heavily calcified lesions as well as occlusions and in-stent restenosis, has been analyzed.

  2. Randomized comparison of final kissing balloon dilatation versus no final kissing balloon dilatation in patients with coronary bifurcation lesions treated with main vessel stenting: the Nordic-Baltic Bifurcation Study III

    DEFF Research Database (Denmark)

    Niemelä, Matti; Kervinen, Kari; Erglis, Andrejs

    2011-01-01

    BACKGROUND: It is unknown whether the preferred 1-stent bifurcation stenting approach with stenting of the main vessel (MV) and optional side branch stenting using drug-eluting stents should be finalized by a kissing balloon dilatation (FKBD). Therefore, we compared strategies of MV stenting......, or stent thrombosis within 6 months. The 6-month major adverse cardiac event rates were 2.1% and 2.5% (P=1.00) in the FKBD and no-FKBD groups, respectively. Procedure and fluoroscopy times were longer and more contrast media was needed in the FKBD group than in the no-FKBD group. Three hundred twenty...... angiographic side branch (re)stenosis, especially in patients with true bifurcation lesions. The simple no-FKBD procedures resulted in reduced use of contrast media and shorter procedure and fluoroscopy times. Long-term data on stent thrombosis are needed....

  3. Evaluation of the 4-French Pulsar-18 Self-expanding Nitinol Stent in Long Femoropopliteal Lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Hailer, Birgit; Kaeunicke, Matthias; Stahlhoff, Wilhelm-Friedrich; Boese, Dirk; Breuckmann, Frank

    2014-01-01

    To evaluate the patency and the freedom of target lesion revascularization of the 4-French Pulsar-18 self-expandable (SE) nitinol stent for the treatment of long femoropopliteal occlusive disease in a two-center, prospective, all-comers registry with a follow-up period of 12 months. This registry enrolled 36 patients with symptomatic femoropopliteal long lesions for recanalization and implantation of the 4-French Pulsar-18 SE nitinol stent. Routine follow-up examination including duplex ultrasound was performed after 6 and 12 months. Primary patency was defined as no binary restenosis on duplex ultrasound (Peak systolic velocitiy ration (PSVR) Pulsar-18 SE nitinol stent for endovascular intervention of femoropopliteal disease with a mean lesion length of 182.3 ± 51.8 mm showed promising primary patency and fTLR rates after 6 and 12 months. Diabetes and renal insufficiency had no negative impact on the patency rate.

  4. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  5. Self-expandable medical memorial metallic stent with 125I seeds for the treatment of esophageal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang Shuo; Lu Bin

    2011-01-01

    Objective: To discuss the curative effect and safety of the implantation of self-expandable medical memorial metallic stent with 125 I seeds for the treatment of advanced esophageal carcinomas. Methods: Implantation of self-expandable medical memorial metallic stent with 125 I seeds was performed in 32 patients with advanced esophageal canner. The clinical data were retrospectively analyzed. The technical success rate, the operation time, the immediate and mid-term effectiveness, the survival time, the complications, the body weight, the blood picture, the immune indexes, the average hospitalization days and hospitalization expenses were analyzed. Results: The average operation time was (18±5) minutes. Successful stent implantation was achieved in all 32 patients (100%). No 125 I seeds fell off during the procedure. The remission rate of dysphagia was 100%. Esophageal restenosis occurred in four patients, and displacement of the stent was seed in one patient. One month after the treatment, 90% of patients had a Karnofsky performance score over 60. The mean survival time was (8.7±6.6) months. The average hospitalization time was (7.8±3.7) days and the mean hospitalization cost was (12±3) thousand Chinese Yuan. Conclusion: For the treatment of esophageal carcinomas, the implantation of self-expandable medical memorial metallic stent with 125 I seeds is safe, effective and simple. This treatment can markedly improve the symptom of dysphagia and significantly prolong the patient's survival time. (authors)

  6. Budd-Chiari syndrome due to prothrombotic disorder: mid-term patency and efficacy of endovascular stents

    Energy Technology Data Exchange (ETDEWEB)

    Pelage, Jean-Pierre; Denys, Alban; Sibert, Annie; Menu, Yves [Department of Radiology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Valla, Dominique [Department of Hepatology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Sauvanet, Alain; Belghiti, Jacques [Department of Surgery, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France)

    2003-02-01

    Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients. (orig.)

  7. Chemico-physical characterisation and in vivo biocompatibility assessment of DLC-coated coronary stents.

    Science.gov (United States)

    Castellino, Micaela; Stolojan, Vlad; Virga, Alessandro; Rovere, Massimo; Cabiale, Karine; Galloni, Marco R; Tagliaferro, Alberto

    2013-01-01

    The vast majority of stent thrombosis occurs in the acute and sub-acute phases and is more common in patients with acute coronary syndromes, due to the thrombotic milieu where stent struts are positioned. Stent thrombosis is likely due to incomplete tissue coverage of metallic stents as the contact between metallic stents and blood elements may lead to platelet adhesion and trigger vessel thrombosis. If a stent is covered after 7 days, the risk that it will be found uncovered at later stages is very low (DLC) coatings, deposited by physical vapour deposition, promote rapid endothelisation of coronary stent devices, with very low platelets activation, reducing thrombotic clots. We relate these behaviours to the surface and bulk material properties of the DLC films, subjected to a comprehensive chemico-physical characterisation using several techniques (X-ray photoelectron spectroscopy, atomic force microscopy, field-emission scanning electron microscope, transmission electron microscopy combined with electron energy loss spectroscopy, Raman and dispersive X-ray spectroscopy). In vivo studies, conducted on 24 pigs, have shown complete endothelisation after 7 days, with no fibrin mesh and with only rare monocytes scattered on the endothelial layer while 30 and 180 days tests have shown reduced inflammatory activation and a complete stabilisation of the vessel healing, with a minimal neointimal proliferation. The integral and permanent DLC film coating improves haemo- and bio-compatibility and leads to an excellent early vessel healing of the stent whilst the extremely thin strut thickness reduces the amount of late neointima and consequently the risk of late restenosis. These data should translate into a reduced acute and sub-acute stent thrombosis.

  8. The placement of Y-shaped titanium-nickel memory alloy stent in the carina: a fundamental study in experimental canines

    International Nuclear Information System (INIS)

    Bian Wei; Shen Che

    2010-01-01

    Objective: To investigate the pathological changes of local airway tissue after inserting Yshaped titanium-nickel memory alloy stent in carina, and to evaluate CT three-dimensional reconstruction technique in postoperative and follow-up observation. Methods: Twelve healthy adult canines were enrolled in this study. Based on the information of the carina obtained from CT three-dimensional reconstruction images, the preparation of Y-shape netlike stent was made by knitting method with single Ni-Ti memory alloy wire. The stent was then inserted in canine's carina with the help of a releasing system. After the operation fiberbronchoscopy and CT three-dimensional reconstruction were performed. The animals were sacrificed 12 weeks after the procedure and the bronchus of the stenting segment was removed and sent for histopathologic examination. Results: Technical success was achieved in all canines with the stent right in the carina. The airway remained unobstructed 12 weeks after the procedure. Histopathologic examination revealed that the stent became partial epithelialization. Conclusion: The Y-shaped titanium-nickel memory alloy stent has good histocompatibility and physicochemical stability and no re-stenosis of the airway develops in the follow-up period of three months. The stent-releasing technique is easy and simple. As a non-invasive and convenient exam, CT three-dimensional reconstruction technique is of great value in postoperative follow-up observation. (authors)

  9. Randomized Comparison of Final Kissing Balloon Dilatation Versus No Final Kissing Balloon Dilatation in Patients With Coronary Bifurcation Lesions Treated With Main Vessel Stenting. Five Year Clinical Outcome in The Nordic-Baltic Bifurcation Study III

    DEFF Research Database (Denmark)

    Niemelä, Matti; Holm, Niels R; Kervinen, Kari

    2015-01-01

    Background- It is unknown whether the preferred 1-stent bifurcation stenting approach with stenting of the main vessel (MV) and optional side branch stenting using drug-eluting stents should be finalized by a kissing balloon dilatation (FKBD). Therefore, we compared strategies of MV stenting......, or stent thrombosis within 6 months. The 6-month major adverse cardiac event rates were 2.1% and 2.5% (P=1.00) in the FKBD and no-FKBD groups, respectively. Procedure and fluoroscopy times were longer and more contrast media was needed in the FKBD group than in the no-FKBD group. Three hundred twenty...... angiographic side branch (re)stenosis, especially in patients with true bifurcation lesions. The simple no-FKBD procedures resulted in reduced use of contrast media and shorter procedure and fluoroscopy times. Long-term data on stent thrombosis are needed. Clinical Trial Registration- URL: http...

  10. Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang

    2010-01-01

    Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)

  11. Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).

    Science.gov (United States)

    Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK

    1996-10-01

    Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.

  12. The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis)

    DEFF Research Database (Denmark)

    Verheye, Stefan; Vrolix, Mathias; Kumsars, Indulis

    2017-01-01

    centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. RESULTS Procedural success in the intention-to-treat population was 100 The primary safety endpoint was target lesion failure (TLF) (cardiac death...... and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. CONCLUSIONS This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes...

  13. Long-term outcomes of coronary artery bypass grafting versus stent-PCI for unprotected left main disease: a meta-analysis.

    Science.gov (United States)

    De Rosa, Salvatore; Polimeni, Alberto; Sabatino, Jolanda; Indolfi, Ciro

    2017-09-06

    Coronary artery bypass graft (CABG) surgery has traditionally represented the standard of care for left main coronary artery (LMCA) disease. However, percutaneous coronary intervention with stent implantation (PCI) has more recently emerged as a valuable alternative. The long-time awaited results of the largest randomized trials on the long-term impact of PCI versus CABG in LMCA disease, the newly published NOBLE and EXCEL studies, revealed contrasting results. Thus, aim of the present meta-analysis was to review the most robust evidence from randomized comparisons of CABG versus PCI for revascularization of LMCA. Randomized studies comparing long-term clinical outcomes of CABG or Stent-PCI for the treatment of LMCA disease were searched for in PubMed, the Chochrane Library and Scopus electronic databases. A total of 5 randomized studies were selected, including 4499 patients. No significant difference between CABG and PCI was found in the primary analysis on the composite endpoint of death, stroke and myocardial infarction (OR = 1·06 95% CI 0·80-1·40; p = 0·70). Similarly, no differences were observed between CABG and PCI for all-cause death (OR = 1·03 95% CI 0·81-1·32; p = 0·81). Although not statistically significant, a lower rate of stroke was registered in the PCI arm (OR = 0·86; p = 0·67), while a lower rate of myocardial infarction was found in the CABG arm (OR = 1·43; p = 0·17). On the contrary, a significantly higher rate of repeat revascularization was registered in the PCI arm (OR = 1·76 95% CI 1·45-2·13; p PCI and CABG for the treatment of LMCA disease in the composite endpoint of death, stroke and myocardial infarction. Hence, a large part of patients with unprotected left main coronary artery disease can be managed equally well by means of both these revascularization strategies.

  14. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    Science.gov (United States)

    Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan

    2017-10-01

    Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Clinical outcomes associated with per-operative discontinuation of aspirin in patients with coronary artery disease: A systematic review and meta-analysis.

    Science.gov (United States)

    Luni, Faraz Khan; Riaz, Haris; Khan, Abdur Rahman; Riaz, Talha; Husnain, Muhammad; Riaz, Irbaz Bin; Khan, Muhammad Shahzeb; Taleb, Mohammed; Kanjwal, Yusuf; Cooper, Christopher J; Khuder, Sadik A

    2017-06-01

    Postoperative state is characterized by increased thrombotic risk by virtue of platelet activation. Whether aspirin ameliorates this risk in patients with established coronary artery disease undergoing cardiac or noncardiac surgery is unknown. We conducted a systematic review and meta-analysis to compare the risk of major adverse cardiac events (MACE) and the risk of bleeding in patients with early (3-5 or more days before surgery) vs. late discontinuation(aspirin. Multiple databases were searched from inception of these databases until March 2015 to identify studies that reported discontinuation of aspirin in patients undergoing surgery. The outcomes measured were all cause mortality, nonfatal myocardial infarction and other relevant thrombotic events (MACE) which also may include, fatal and nonfatal MI, stent thrombosis and restenosis, stroke, perioperative cardiovascular complications (heart failure, MI, VTE, acute stroke) and perioperative bleeding during the perioperative period to up to 30 days after surgery. A total of 1,018 titles were screened, after which six observational studies met the inclusion criteria. Our analysis suggests that there is no difference in MACE with planned discontinuation of aspirin (OR = 1.17, 95% CI = 0.76-1.81; P = 0.05; I 2  = 55%). Early discontinuation of aspirin showed a decreased risk of peri-operative bleeding (OR 0.82, 95% CI = 0.67-0.99; P = 0.04; I 2  = 42%). Our analysis suggests that planned short-term discontinuation in the appropriate clinical setting appears to be safe in the correct clinical setting with no increased risk of thrombotic events and with a decreased risk of bleeding. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  17. Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, Denise Oliveira, E-mail: dennizmo@yahoo.com.br; Gomes, Vitor Osório; Lasevitch, Ricardo; Smidt, Luis; Azeredo, Marco Aurélio; Ledur, Priscila; Bodanese, Rodrigo; Sinnott, Leonardo; Moriguchi, Emílio; Caramori, Paulo [Hospital São Lucas PUC, Porto Alegre, RS (Brazil)

    2014-09-15

    Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. To evaluate the efficacy and safety of drug-eluting stents in the real world. We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the 'real world' may benefit from drug-eluting stenting with excellent, long-term results.

  18. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  19. Development and characterization of a coronary polylactic acid stent prototype generated by selective laser melting.

    Science.gov (United States)

    Flege, Christian; Vogt, Felix; Höges, Simon; Jauer, Lucas; Borinski, Mauricio; Schulte, Vera A; Hoffmann, Rainer; Poprawe, Reinhart; Meiners, Wilhelm; Jobmann, Monika; Wissenbach, Konrad; Blindt, Rüdiger

    2013-01-01

    In-stent restenosis is still an important issue and stent thrombosis is an unresolved risk after coronary intervention. Biodegradable stents would provide initial scaffolding of the stenosed segment and disappear subsequently. The additive manufacturing technology Selective Laser Melting (SLM) enables rapid, parallel, and raw material saving generation of complex 3- dimensional structures with extensive geometric freedom and is currently in use in orthopedic or dental applications. Here, SLM process parameters were adapted for poly-L-lactid acid (PLLA) and PLLA-co-poly-ε-caprolactone (PCL) powders to generate degradable coronary stent prototypes. Biocompatibility of both polymers was evidenced by assessment of cell morphology and of metabolic and adhesive activity at direct and indirect contact with human coronary artery smooth muscle cells, umbilical vein endothelial cells, and endothelial progenitor cells. γ-sterilization was demonstrated to guarantee safety of SLM-processed parts. From PLLA and PCL, stent prototypes were successfully generated and post-processing by spray- and dip-coating proved to thoroughly smoothen stent surfaces. In conclusion, for the first time, biodegradable polymers and the SLM technique were combined for the manufacturing of customized biodegradable coronary artery stent prototypes. SLM is advocated for the development of biodegradable coronary PLLA and PCL stents, potentially optimized for future bifurcation applications.

  20. Toxic vessel reaction to an absorbable polymer-based paclitaxel-eluting stent in pig coronary arteries.

    Science.gov (United States)

    Jabara, Refat; Chronos, Nicolas; Tondato, Fernando; Conway, Damian; Molema, Warner; Park, Kenneth; Mabin, Tom; King, Spencer; Robinson, Keith

    2006-08-01

    The goal of this study was to evaluate a new drug-eluting stent (DES) comprising a bioabsorbable polymer eluting a moderate dose of paclitaxel in a clinically relevant animal model. Although DES limit restenosis, adverse vascular pathologies and toxicities continue to be of major concern. Optimization of DES components, especially completely absorbable polymers, may reduce these toxicities. Bare-metal (BM), absorbable polymer coating only (POLY), and polymer-based paclitaxel-eluting (PACL) stents were implanted in porcine coronary arteries using intravascular ultrasound (IVUS) to optimize stent apposition. The dose density of paclitaxel was 0.30-0.35 mcg/mm2, with in vitro elution studies demonstrating a gradual elution over 6-8 weeks. The animals were terminated at 1 week, 1 month and 3 months. Histopathologic and histomorphometric analyses were perform. The arteries with PACL showed extensive smooth muscle cell necrosis at 1 week and poor apposition of stent struts at 1 month (malapposition measured as gap width between strut and internal elastic lamina), with greater gap width compared to the BM and POLY groups (0.22 mm +/- 0.02 vs. 0.03 mm +/- 0.02 and 0.02 mm +/- 0.01, respectively; p stent malapposition and late neointimal thickening. Since the therapeutic window for paclitaxel may be narrower than currently inferred, thorough preclinical testing coupled with the polymer development process for stents eluting paclitaxel is needed.

  1. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    BACKGROUND: In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery...... disease who were receiving routine clinical care with no direct follow-up. METHODS: We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five...... Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial...

  2. [Tracheobronchial stents: a retrospective analysis of indications, results and in particular complications].

    Science.gov (United States)

    Tonn, H; Mall, W; Schneider, K-D; Schönhofer, B

    2008-10-01

    Tracheobronchial stents are inserted mainly in cases of malignant and benign airway stenosis. Further indications are esophago-tracheal fistulas, mediastinal fistulas and tracheomalacia. A retrospective analysis was conducted on patients' records, information provided by the general practitioners and relatives of the patients from July 1993 to December 2006 in the Department of Pneumology of the Heidehaus Hospital Hannover (since 6/05 Department of Pneumology and Internal Intensive Care Medicine, Oststadt-Heidehaus Hospital). During the observation period of 13 years a total of 269 stents (177 permanent, 92 temporary) were implanted in 207 patients (1.3 stents per patient). The vast majority of patients (173/207) suffered from an underlying malignancy. About half of the stents were deployed in the trachea. The median length of placement was 116 days in patients with malignancies and 313 days in patients with benign diseases. In about 40 % of the patients notable complications were observed which were directly or indirectly associated with the stents. These findings show the importance of a critical indication for stent implantation. In benign diseases a stent can remain for years inside the tracheobronchial system, if it is well tolerated in the beginning. In malignant diseases the result depends decisively on the stage of the tumour: has the stent been implanted before any other tumour therapy is started or is it an end-stage tumor with no other therapeutic option? In general, complications of stents occur quite frequently. The analysis of stent data leads to some aspects for the prevention of stent-related complications. There should be a strict indication and appropriate choice of stent material. Nevertheless, there remains an ethical dilemma in patients with end-stage disease as to whether to implant a stent or to do nothing against the tumor, because the benefit immediately after stent insertion vanishes with progression of the tumour, so causing extra

  3. Radiation protection review in nuclear medicine and analysis of new medical techniques. ACDOS-5-P-3 project. Final report, part 2

    International Nuclear Information System (INIS)

    Di Trano, Jose L.; Rojo, Ana M.; Kunst, Juan J.

    2003-01-01

    The intravascular brachytherapy (IVB) is a new application of ionizing radiation in the interventional cardiology and radioncology and medical physics field. The source is temporarily or permanently placed inside the vessel to prevent the restenosis. The restenosis is the re-narrowing of the lumen of the artery up to 50 % in the primary site of the treatment. Its incidence is 30 to 50 % following percutaneous transluminal coronary angioplasty (PTCA), and 20 % after stenting. The IVB is apply to prevent peripheric and coronary restenosis. The radiation is delivered through a catheter placed across the lesion, or by implanting a radioactive stent into a targeted lesion. Both beta and gamma radiation is used depending on the depth of penetration required. There isn't a definitive conclusion regarding the advantage of each one. The experience and the knowledge about the effects of ionizing radiation reveals that the cells in high rate division are the main target. It determines the selection of this type of radiation to prevent and treat the main component of restenosis: the neo intimal hyperplasia. Recently, several clinical trials have been approved in multicenter studies to assess the effectiveness and safety of IVB in reducing the restenosis rate. During the year 2000, Cordis's Checkmate System and Novoste's Beth-Cath System received Food and Drug Administration (FDA) approval to treat patients with in-stent restenosis. This approval marks a significant achievement for U.S. clinicians/researchers, who have devoted more than four years of clinical study to evaluate the effects and intricacies of vascular brachytherapy. The approval mechanism anticipates a follow up of the cases for an evaluation of the conditions of the definitive authorization. The IVB showed to be useful in the treatment of neo intimal hyperplasia post angioplasty injury and in-stent restenosis. Nevertheless there are uncertainties to be studied before the routine clinical application. These

  4. Balloon dilation and airway stenting for benign and malignant tracheal stenosis

    International Nuclear Information System (INIS)

    Guo Jianhai; Yang Renjie; Zhang Hongzhi

    2009-01-01

    Objective: To assess the effectiveness of balloon dilation and airway stenting performed under fluoroscopic guidance for the treatment of benign and malignant tracheal stenosis. Methods: Under fluoroscopic guidance, balloon dilation and airway stenting were performed in 45 patients with tracheobronchial stricture. Of the 45 patients,malignant tracheal stenosis was seen in 37, including mediastinal nodal metastases (n=14), esophageal carcinoma (n=13), lung carcinoma (n= 4), adenocarcinoma of bronchus (n=3), lymphoma (n=2) and laryngocarcinoma (n=1), and benign tracheal stenosis was seen in 8, including endobronchial tuberculosis (n=6), retrosternal thyroid adenoma (n=1) and endotracheal intubation (n=1). Airway stenting with self-expandable metal stent was employed in 38 patients and balloon dilation in 7 patients. All the procedures were performed under fluoroscopic guidance. Results: A total of 53 self-expandable metal stents was implanted in 38 patients. The clinical symptoms were immediately relived after the procedure in all patients except for one patient who died from choking of sputum. No stent migration was observed. Restenosis developed in 4 patients, which was successfully treated with repeated stenting and balloon dilation. Nineteen times of balloon dilation procedure were accomplished in 7 patients. Marked remission of clinical symptoms was seen in most cases. During a follow-up period (ranged from 0 to 124 months with a mean of 24.5 months) 31 patients died. Conclusion: For both benign and malignant tracheal stenosis, balloon dilation with airway stenting performed under fluoroscopic guidance is a safe and efficient therapy with instant curative effect in relieving clinical symptoms. (authors)

  5. Biodegradable Stents for Caustic Esophageal Strictures: Do They Work?

    Science.gov (United States)

    Kochhar, Rakesh; Samanta, Jayanta; Basha, Jahangeer; Verma, Abhai; Choudhuri, Gourdas; Lakhtakia, Sundeep; Reddy, D Nageshwar

    2017-08-01

    Biodegradable (BD) stents have been used for the management of various esophageal strictures (ES) but the experience of its use in caustic strictures is limited. The present study, aimed at evaluating efficacy of BD stents for the treatment of refractory caustic-induced ES, was a retrospective multi-center study conducted at three tertiary care centers in India wherein adult patients with refractory caustic induced strictures underwent placement of a BD stent. Patients were followed up for immediate complications and long term outcome. All 13 patients (39.3 ± 15.1 years) underwent successful BD stent placement. Retrosternal chest pain occurred in 2 patients and stent migration in 1 (7.6%) patient. At 3 months, restenosis with recurrence of dysphagia was seen in nine (69.2%) patients, at 6 months, 10 (77%) patients had dysphagia of whom three underwent surgery and the remaining seven patients required dilatations. At 1 year, one patient remained asymptomatic while nine had dysphagia. The requirement for dilatation was once in 3 months in seven patients & once in a month in two patients. At 2 years, the requirement of dilatations was further reduced to once in 4-6 months in all patients. Over a 3 year follow up three (23%) patients had undergone surgery, one was free of symptoms while nine patients continued to be on periodic dilatation although the requirement had reduced to once in 4-6 months. Efficacy of BD stents in patients with caustic-induced ES is limited and the short term radial force applied by the currently available BD stents is inadequate to provide long term relief in such patients.

  6. Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials.

    Science.gov (United States)

    Bundhun, Pravesh Kumar; Yanamala, Chandra Mouli; Huang, Wei-Qiang

    2017-03-16

    Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 - 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 - 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 - 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 - 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 - 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 - 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 - 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 - 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 - 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 - 1.82; P = 0.78 respectively. At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late

  7. Cost-effectiveness analysis of biodegradable polymer versus durable polymer drug-eluting stents incorporating real-world evidence.

    Science.gov (United States)

    Teng, Monica; Zhao, Ying Jiao; Khoo, Ai Leng; Ananthakrishna, Rajiv; Yeo, Tiong Cheng; Lim, Boon Peng; Chan, Mark Y; Loh, Joshua P

    2018-06-05

    Compared with second-generation durable polymer drug-eluting stents (DP-DES), the cost-effectiveness of biodegradable polymer drug-eluting stents (BP-DES) remains unclear in the real-world setting. We assessed the cost-effectiveness of BP-DES in patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We developed a decision-analytic model to compare the cost-effectiveness of BP-DES to DP-DES over one year and five years from healthcare payer perspective. Relative treatment effects during the first year post-PCI were obtained from a real-world population analysis while clinical event risks in the subsequent four years were derived from a meta-analysis of published studies. At one year, based on the clinical data analysis of 497 propensity-score matched pairs of patients, BP-DES were associated with an incremental cost-effectiveness ratio (ICER) of USD20,503 per quality-adjusted life-year (QALY) gained. At five years, BP-DES yielded an ICER of USD4,062 per QALY gained. At the willingness-to-pay threshold of USD50,400 (one gross domestic product per capita in Singapore in 2015), BP-DES were cost-effective. Sensitivity analysis showed that the cost of stents had a significant impact on the cost-effectiveness of BP-DES. Threshold analysis demonstrated that if the cost difference between BP-DES and DP-DES exceeded USD493, BP-DES would not be cost-effective in patients with one-year of follow-up. BP-DES were cost-effective compared with DP-DES in patients with coronary artery disease at one year and five years after PCI. It is worth noting that the cost of stents had a significant impact on the findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Effect of kudiezi injection on stent thrombosis and matrix metalloproteinase in patients with PCI

    International Nuclear Information System (INIS)

    Wang Zhihui; Zhang Jing; Xing Yue

    2010-01-01

    Objective: To investigate the effects of Kudiezi injection on stent thrombosis and the levels of matrix metalloproteinase (MMPs) and thromboxane B 2 (TXB2) in elderly patients with percutaneous coronary intervention (PCI), and investigate the mechanism of Kudiezi on the decrease of stent thrombosis. Methods: Forty elderly patients were divided into two groups (Kudiezi group and control group) after PCI. Kudiezi were administered into patients in Kudiezi group and the patients in control group were treated with regular medication. The angioraphic and clinic follow-up outcomes of 40 elderly patients with PCI there retrospectively analyze. Stent thrombosis (ST) was confirmed by angiography. The levels MMPs and TXB2 in Kudiezi group (n=20) and control group (n=20) were determined before stent implantation and after 6 months. Major cardiac events (restenosis, cardiac death, myocardiac infarction, revasculation) were observed during follow-up. Results: The levels of MMPs and TXB2 in Kudiezi and control group decreased significantly after PCI. The levels of MMPs and TXB2 in Kudiezi group were less than that in control group after PCI. The levels of MMPs and TXB 2 in all patients group were significantly different between pre-procedure and post-procedure (P 2 . (authors)

  9. Enterprise stent for the treatment of symptomatic intracranial atherosclerotic stenosis: an initial experience of 44 patients.

    Science.gov (United States)

    Feng, Zhengzhe; Duan, Guoli; Zhang, Ping; Chen, Lei; Xu, Yi; Hong, Bo; Zhao, Wenyuan; Liu, Jianmin; Huang, Qinghai

    2015-10-08

    Wingspan stenting for the treatment of complex intracranial atherosclerotic stenosis (ICAS), i.e., that involving tortuous vascular pathways, long (>15 mm) lesions or arterial bifurcations, has a relatively high risk of complications. This retrospective study assessed the safety and efficacy of undersized balloon angioplasty followed by deployment of the more flexible Enterprise stent for the treatment of complex symptomatic ICAS. Forty-four patients on combined antiplatelet therapy and intensive risk factor management and a symptomatic 70-99% stenosis of a major intracranial artery in complex settings that was treated with balloon angioplasty and Enterprise stent deployment between July 2009 and August 2013 were enrolled. Primary outcome was occurrence of ischemic or hemorrhagic stroke or death within 30 days after intervention. Secondary outcomes included procedural success (defined as achievement of 50% in-stent restenosis after mean 22 months follow-up. In this retrospective, single-center experience, undersized balloon angioplasty followed by Enterprise stent deployment appears technically feasible with a relatively low rate of complications for the treatment of complex symptomatic ICAS. Prospective, multicenter, randomized controlled trials against optimal medical management are warranted.

  10. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  11. Teaching meta-analysis using MetaLight

    Directory of Open Access Journals (Sweden)

    Thomas James

    2012-10-01

    Full Text Available Abstract Background Meta-analysis is a statistical method for combining the results of primary studies. It is often used in systematic reviews and is increasingly a method and topic that appears in student dissertations. MetaLight is a freely available software application that runs simple meta-analyses and contains specific functionality to facilitate the teaching and learning of meta-analysis. While there are many courses and resources for meta-analysis available and numerous software applications to run meta-analyses, there are few pieces of software which are aimed specifically at helping those teaching and learning meta-analysis. Valuable teaching time can be spent learning the mechanics of a new software application, rather than on the principles and practices of meta-analysis. Findings We discuss ways in which the MetaLight tool can be used to present some of the main issues involved in undertaking and interpreting a meta-analysis. Conclusions While there are many software tools available for conducting meta-analysis, in the context of a teaching programme such software can require expenditure both in terms of money and in terms of the time it takes to learn how to use it. MetaLight was developed specifically as a tool to facilitate the teaching and learning of meta-analysis and we have presented here some of the ways it might be used in a training situation.

  12. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  13. In-Vitro Evaluation of Coronary Stents and 64-Detector-Row Computed Tomography Using a Newly Developed Model of Coronary Artery Stenosis

    International Nuclear Information System (INIS)

    Schlosser, T.; Scheuermann, T.; Ulzheimer, S.; Mohrs, O.K.; Kuehling, M.; Al brecht, P.E.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2008-01-01

    Background: Stent implantation is the predominant therapy for non-surgical myocardial revascularization in patients with coronary artery disease. However, despite substantial advances in multidetector computed tomography (MDCT) coronary imaging, a reliable detection of coronary in-stent restenosis is currently not possible. Purpose: To examine the ability of 64-detector-row CT to detect and to grade in-stent stenosis in coronary stents using a newly developed ex-vivo vessel phantom with a realistic CT density pattern, artificial stenosis, and a thorax phantom. Material and Methods: Four different stents (Liberte and Lunar ROX, Boston Scientific; Driver, Medtronic; Multi-Link Vision, Guidant) were examined. The stents were placed on a polymer tube with a diameter of 2.5, 3.0, 3.5, or 4.0 mm. Different degrees of stenosis (0%, 30%, 50%, 70-80%) were created inside the tube. For quantitative analysis, attenuation values were measured in the non-stenotic vessel outside the stent, in the non-stenotic vessel inside the stent, and in the stenotic area inside the stent. The grade of stenosis was visually assessed by two observers. Results: All stents led to artificial reduction of attenuation, the least degree of which was found in the Liberte stent (11.3±10.2 HU) and the Multi-Link Vision stent (17.6±17.9 HU; P 0.25). Overall, the non-stenotic vessel was correctly diagnosed in 55.5%, the low-grade stenosis in 58.3%, the intermediate stenosis in 63.8%, and the high-grade stenosis in 80.5%. In the 3.0-, 3.5-, and 4.0-mm vessels, in none of the cases was a non-stenotic or low-grade stenotic vessel misdiagnosed as intermediate or high-grade stenosis. The average deviation from the real grade of stenosis was 0.40 for the Liberte stent, 0.46 for the Lunar ROX stent, 0.45 for the Driver stent, and 0.58 for the Multi-Link Vision stent. Conclusion: Our ex-vivo data show that non-stenotic stents and low-grade in-stent stenosis can be reliably differentiated from intermediate and

  14. Dose-volume histograms based on serial intravascular ultrasound: a calculation model for radioactive stents

    International Nuclear Information System (INIS)

    Kirisits, Christian; Wexberg, Paul; Gottsauner-Wolf, Michael; Pokrajac, Boris; Ortmann, Elisabeth; Aiginger, Hannes; Glogar, Dietmar; Poetter, Richard

    2001-01-01

    Background and purpose: Radioactive stents are under investigation for reduction of coronary restenosis. However, the actual dose delivered to specific parts of the coronary artery wall based on the individual vessel anatomy has not been determined so far. Dose-volume histograms (DVHs) permit an estimation of the actual dose absorbed by the target volume. We present a method to calculate DVHs based on intravascular ultrasound (IVUS) measurements to determine the dose distribution within the vessel wall. Materials and methods: Ten patients were studied by intravascular ultrasound after radioactive stenting (BX Stent, P-32, 15-mm length) to obtain tomographic cross-sections of the treated segments. We developed a computer algorithm using the actual dose distribution of the stent to calculate differential and cumulative DVHs. The minimal target dose, the mean target dose, the minimal doses delivered to 10 and 90% of the adventitia (DV10, DV90), and the percentage of volume receiving a reference dose at 0.5 mm from the stent surface cumulated over 28 days were derived from the DVH plots. Results were expressed as mean±SD. Results: The mean activity of the stents was 438±140 kBq at implantation. The mean reference dose was 111±35 Gy, whereas the calculated mean target dose within the adventitia along the stent was 68±20 Gy. On average, DV90 and DV10 were 33±9 Gy and 117±41 Gy, respectively. Expanding the target volume to include 2.5-mm-long segments at the proximal and distal ends of the stent, the calculated mean target dose decreased to 55±17 Gy, and DV 90 and DV 10 were 6.4±2.4 Gy and 107±36 Gy, respectively. Conclusions: The assessment of DVHs seems in principle to be a valuable tool for both prospective and retrospective analysis of dose-distribution of radioactive stents. It may provide the basis to adapt treatment planning in coronary brachytherapy to the common standards of radiotherapy

  15. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    International Nuclear Information System (INIS)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis; Padayachee, Soundrie; Karunanithy, Narayan; Ahmed, Irfan; Zayed, Hany; Katsanos, Konstantinos

    2015-01-01

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery

  16. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

  17. Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study

    International Nuclear Information System (INIS)

    Zhu, Yue-Qi; Li, Ming-Hua; Xie, Jian; Tan, Hua-Qiao; Wang, Jian-Bo; Cheng, Ying-Sheng

    2010-01-01

    We designed a carotid siphon (CS) aneurysm model in dogs to test a new stent graft (the Willis covered stent) and compared tissue reaction over 12-month follow-up versus a comparison group with stents implanted in straight vessels. Twenty-four saccular sidewall aneurysms (group A) and 12 CS aneurysms (group B) were created surgically. A Willis stent graft was implanted in each aneurysm. Angiography was performed immediately and at 1-, 3-, 6- and 12-month post-implantation to investigate aneurysm isolation, endoleak, stent angulation, parent artery (PA) patency and restenosis. Light and scanning electron microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress. Immediate angiography demonstrated mild endoleak in two aneurysms and three stent angulations in group B. Follow-up at 12 months revealed resolved endoleaks, occlusion in one PA and mild stenosis in three in group B. In group A, occlusion occurred in one PA and mild stenosis in two. Light microscopy revealed new intima, and all aneurysm sacs were filled with thrombi. In group B, endothelial progress was complete at 12 months, and closely correlated with haemodynamic changes. Application of a Willis stent graft is a feasible method of treating CS aneurysms, and it exhibits a prolonged endothelial progress compared with that in straight vessels. (orig.)

  18. Use of Self-Expanding Stents for the Treatment of Vertebral Artery Ostial Stenosis: a Single Center Experience

    International Nuclear Information System (INIS)

    Chung, Sun Young; Lee, Deok Hee; Choi, Jin Woo; Choi, Byung Se; In, Hyun Sin; Kim, Sun Mi; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2010-01-01

    To evaluate our early experience using self-expanding stents to treat atherosclerotic vertebral artery ostial stenosis (VAOS), with respect to technical feasibility and clinical and imaging follow-up results. A total of 20 lesions in 20 patients underwent stenting of the VAOS using a self-expanding stent (Precise RX; Cordis Neurovascular, Miami Lakes, FL). Two patients were asymptomatic. We analyzed the technical success rate, causes of technical failure, occurrence of any vascular or neurological event, and the occurrence of any neurological abnormality or in-stent restenosis (ISR) seen on follow-up. The imaging follow-up was performed with Doppler ultrasound (DUS) as a primary screening modality. One instance of technical failure was caused by failure of the guidewire passage. The stent diameter was 5 mm, and post-stenting balloon dilatations were necessary in all cases. Stent misplacement requiring placement of an additional stent occurred in four cases. Following a 14.8 month average clinical follow-up time, two patients showed anterior circulation ischemia, which was not attributed to the VAOS we treated. Following a 13.7 month average DUS follow-up, five patients showed a mild degree of diffuse or focal intimal thickening in the stent lumen; however, none of the stenosis showed luminal loss of more than 50% and no stent fracture was noted. The use of self-expanding stents for treating VAOS was technically feasible and helped to improve artery patency during our limited follow-up interval

  19. Biomechanical analysis on stent materials used as cardiovascular implants

    Science.gov (United States)

    Kumar, Vasantha; Ramesha, C. M.; Sajjan, Sudheer S.

    2018-04-01

    Atherosclerosis is the most common cause of death in the world, accounting for 48% of all deaths in the world. Atherosclerosis, also known as coronary artery disease occurs when excess cholesterol attaches itself to the walls of blood vessels. Coronary stent implantation is one of the most important procedures to treating coronary artery disease such atherosclerosis. Due to its efficiency, flexibility and simplicity, the use of coronary stents procedures has increased rapidly. In order to have better output of stent implantation, it is needed to study and analyze the biomechanical behavior of this device before manufacturing and put into use. Biomaterials are commonly used for medical application in cardiovascular stent implantation. A biomaterial is a non-viable material used as medical implant, so it is intended to interact with biological system. In this paper, an explicit dynamic analysis is used for analyzing the biomechanical behavior of cardiovascular stent by using finite element analysis tool, ABAQUS 6.10. Results showed that a best suitable biomaterial for cardiovascular stent implants, which exhibits an outstanding biocompatibility and biomechanical characteristics will be aimed at which will be quite useful to the human beings worldwide.

  20. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  1. Clinical evaluation of the efficacy and influencing factors for stent placement in treating benign and malignant esophageal stenosis

    International Nuclear Information System (INIS)

    Guo Xiaohua; He Jianrong; Lin Kaiqin; Jin Honglai; Li Maoquan; Zhang Qing

    2003-01-01

    Objective: To evaluate clinical effectiveness and influence factors in the treatment of benign and malignant esophageal stenosis by placing esophageal stent. Methods: A series of this research comprised of 29 cases with esophageal cancer, 10 cardiac carcinoma, 5 cardiac achalasia, 6 benign esophageal stricture after operation. The lengths of lesion ranged from 2 to 14 cm in length with mean of 7.3 cm. Fistula were found among malignant esophageal stenosis in 6 cases. According to the dysphagia scores, 12 cases were designated at I grade, 31 with II, and 14 with III. 46 cases of malignancy were undertaken radiation therapy combined with transcatheter arterial chemotherapy from 15 to 30 days after stent placement. Results: 62 stents were placed in 57 cases (52 domestic stents, 10 Boston ultraflex), including 4 cases with 2 stents being once placed, 1 case with second time stent placement because of restenosis 4 month later. All stents were placed successfully without serious complications, such as esophageal perforation, massive hemorrhage. 5 cases of cardiac achalasia and 6 cases of benign esophageal stricture are still alive now. The survival rates of 6, 12, 24 and 36 months in 46 malignant cases, were 67.4%(31/46), 43.5%(20/46), 26.1%(12/46), and 19.6(9/46) respectively. Dysphagia were relieved significantly from 7 to 15 days after stent placement. Conclusions: Esophageal stent placement combined with radiation therapy and transcatheter arterial chemotherapy could improve patient life qualities and survival rates significantly in malignant stricture. The effects on benign esophageal stricture by stent placement are comparable with that of surgical treatment

  2. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  3. Impact of lesion morphology on angiographic and clinical outcomes in patients with chronic total occlusion after recanalization with drug-eluting stents: a multislice computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Tsuyoshi [Toyohashi Heart Center, Toyohashi (Japan); Nagoya City University Graduate School of Medical Sciences, Department of Cardio-Renal Medicine and Hypertension, Nagoya (Japan); Tsuchikane, Etsuo; Nasu, Kenya; Kimura, Masashi; Terashima, Mitsuyasu; Kinoshita, Yoshihisa; Habara, Maoto; Suzuki, Takahiko [Toyohashi Heart Center, Toyohashi (Japan); Suzuki, Yoriyasu; Ehara, Mariko [Nagoya Heart Center, Nagoya (Japan); Ohte, Nobuyuki [Nagoya City University Graduate School of Medical Sciences, Department of Cardio-Renal Medicine and Hypertension, Nagoya (Japan)

    2015-10-15

    The aim of this study was to investigate the multislice computed tomography (MSCT) parameters associated with adverse outcomes after chronic total occlusion percutaneous coronary intervention (CTO-PCI) with drug-eluting stents. A total of 285 patients who underwent MSCT before CTO-PCI were analyzed. Lesion morphology was assessed with MSCT. Angiographic restenosis, reocclusion, and MACE (a composite of cardiac death, myocardial infarction, stent thrombosis, and target lesion revascularization) were analyzed. MACE was observed in 36 patients (13.6 %). Occlusion length was greater (39.5 ± 19.9 mm vs. 22.3 ± 13.7 mm, p < 0.01), minimal vessel area smaller (11.2 ± 5.7 mm{sup 2} vs. 14.5 ± 5.6 mm{sup 2}, p < 0.01), and severe calcification more common (36 % vs. 12 %, p < 0.01) in the MACE group compared to the non-MACE group. We defined occluded length >25.4 mm, minimal vessel area <11.9 mm{sup 2}, which were identified by receiver operating characteristic analysis, and severe calcification as CT-derived risk factors. Angiographic restenosis (60 % vs. 12 % vs. 7 %, p < 0.01), reocclusion (29 % vs. 2 % vs. 2 %, p < 0.01), and MACE (43 % vs. 6 % vs. 3 %, p < 0.01) were more common in patients with 2 or more risk factors than in those with 1 or 0. MSCT characteristics associated with adverse outcomes after CTO-PCI were occlusion length, minimal vessel area, and severe calcification. (orig.)

  4. Percutaneous transluminal angioplasty and stent placement for iliofemoral arterial atherosclerotic occlusive disease

    International Nuclear Information System (INIS)

    Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui

    2006-01-01

    Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)

  5. EFFECT OF STENT ABSORBED c-myc ANTISENSE OLIGODEOXYNUCLEOTIDE ON SMOOTH MUSCLE CELLS APOPTOSIS IN RABBIT CAROTID ARTERY

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战

    2002-01-01

    Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.

  6. Efficiency and safety of the intraluminal stent as a treatment malignant obstruction of the digestive tract

    International Nuclear Information System (INIS)

    Yu Xixiang; Si Tongguo; Pan Xiaohui; Yang Hui; Nan Yi; Huang Linfen; Feng Xiaofeng; Mao Aiwu

    2006-01-01

    Objective: To evaluate the efficiency and safety of intraluminal stent as a treatment of malignant obstruction of digestive tract and esophago-bronchial fistula. Methods: In total 71 patients suffered with malignant obstruction or esophago-bronchial fistula were treated with permanent nickel-titanium alloy, partially covered stents. All the procedures were performed under DSA guidance. Inserted via the oral anal access, the stents were placed at the sites of obstructions or the fistulas. Esophagogram or colonogram were done before and post the intervention. The clinical efficiency was assessed by function of swallowing or defecation in follow-up. Results: In 62 patients (96.9%), function of swallowing was restored after the stent was placed in upper digestive tract without drinking triggered coughing. Symptoms were immediately relieved after the stent was placed in sigmoid colon or rectum. Displacement of stents was seen in 2 cases (2.8%); restenosis in 2 (2.8%); hoarse voice was noted in 1 case (1.4%); intense thoracic pain was complained in 2 cases (2.8%); mild pain was noted in 12 cases (16.9%); and massive hemorrhage was complicated in 1 case (1.4%). All complications were successfully controlled after proper treatment. Conclusion: It is an effective, easy and safe method to treat malignant obstruction of digestive tract or esophago-bronchial fistula using partially covered nickel-titanium alloy stent. (authors)

  7. Coronary Stents in Diabetic Patients: State of the Knowledge.

    Science.gov (United States)

    Codner, Pablo; Gurm, Hitinder Singh; Motivala, Apurva

    2017-04-01

    This review article aims to summarize the findings of the most relevant research that compared the use of paclitaxel vs. "limus" based drug eluting stent (DES) in diabetic patients and to define the current state of knowledge with new stent technologies in this patient population. Since drug eluting stents (DES) were introduced, it has been of great interest to establish whether paclitaxel or sirolimus eluting stents have the same safety and efficacy features for patients with coronary artery disease. The answer to this question is particularly relevant for diabetic patients. Several randomized trials, registry-based studies, and meta-analyses have assessed the performance of these different DES in diabetic patients. The most recently published data favors limus over paclitaxel DES in diabetic patients, but most of these studies compared first vs. second generation DES with the inherent caveats of comparing different platforms, alloys, and drug delivery vehicles. In this literature review, we found that there is robust evidence favoring the use of DES over bare metal stents in diabetic patients with coronary artery disease. We also found that the current state of knowledge is that the everolimus eluting stents have better safety and efficacy than paclitaxel eluting stents in diabetic patients and hence should be the preferred choice. New revascularization strategies including bio-absorbable scaffolds, polymer free stents, and bio-degradable polymers are being studied in diabetic patients with encouraging results.

  8. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.

    Science.gov (United States)

    Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2014-03-01

    Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  9. Fat-Suppressed Gadolinium-Enhanced Three-Dimensional Magnetic Resonance Angiography Adequately Depicts the Status of Iliac Arteries Following Atherectomy and Stent Placement

    International Nuclear Information System (INIS)

    Amano, Yasuo; Gemma, Kazuhito; Kawamata, Hiroshi; Kumazaki, Tatsuo

    1998-01-01

    Fat-suppressed, three-dimensional magnetic resonance angiography (3D MRA) was performed on nine patients with 11 iliac artery stenoses following atherectomy or stent placement. The MRA accurately depicted continued patency, restenosis, or aneurysm formation when compared with immediate posttreatment conventional arteriography. Therefore MRA is accurate and can be used independently for clinical decision making

  10. Comparison of the safety and efficacy for application of (cypher)TM and (taxus)TM coronary stent in patients with coronary heart disease and concurrent diabetic

    International Nuclear Information System (INIS)

    Zhang Junjie; Chen Shaoliang; Chen Huaixin; Li Zhiheng; Lin Yanting

    2005-01-01

    Objective: To compare the relative safety and efficacy of Cypher and Taxus stent in coronary heart disease complicated with diabetes. Methods: A retrospective study of our hospital's Cardiology database containing one hundred and twenty-two CHD complicated with diabetes undergone selective or urgent implantation of DES stent between June 2002 and February 2004 were divided into Cypher stent group (n=31) and Taxus stent group (n=91). The endpoints included cardiac death ,myocardial infarction (MI) and TLR at 6-month. Results: 122 patients with majority of males (80%) and mean age of 56 ± 11 years. The baseline characteristics were similar in both groups. Majority lesions treated were consisted of AHA/ACC Type B2/C (75%). Compared to the Taxus group, the Cypher group had a smaller mean reference diameter (2.4±0.6 mm versus 2.6±0.7 mm, P TM and (Taxus) TM coronary stents are proved to be equally safe and effective with low rate of clinical restenosis, TLR and MACE at 6-month in coronary heart disease complicated with diabetes patients. (authors)

  11. Hematopoietic stem cell capture and directional differentiation into vascular endothelial cells for metal stent-coated chitosan/hyaluronic acid loading CD133 antibody.

    Science.gov (United States)

    Zhang, Shixuan; Zhang, Fan; Feng, Bo; Fan, Qingyu; Yang, Feng; Shang, Debin; Sui, Jinghan; Zhao, Hong

    2015-03-01

    A series of metal stents coated with chitosan/hyaluronic acid (CS/HA) loading antibodies by electrostatic self-assembled method were prepared, and the types of cells captured by antibodies and their differentiation in vascular endothelial cells (ECs) evaluated by molecular biology and scanning electron microscope. The results showed that CD133 stent can selectively capture hematopoietic stem cells (HSC),which directionally differentiate into vascular ECs in peripheral blood by (CS/HA) induction, and simultaneously inhibit migration and proliferation of immune cells and vascular smooth muscle cells (MCs). CD34 stent can capture HSC, hematopoietic progenitor cells that differentiate into vascular ECs and immune cells, promoting smooth MCs growth, leading to thrombosis, inflammation, and rejection. CD133 stent can be implanted into miniature pig heart coronary and can repair vascular damage by capturing own HSC, thus contributing to the rapid natural vascular repair, avoiding inflammation and rejection, thrombosis and restenosis. These studies demonstrated that CD133 stent of HSC capture will be an ideal coated metal stent providing a new therapeutic approach for cardiovascular and cerebrovascular disease.

  12. Prevention of postcoronary angioplasty restenosis by omega-3 fatty acids: main results of the Esapent for Prevention of Restenosis ITalian Study (ESPRIT).

    Science.gov (United States)

    Maresta, Aleardo; Balduccelli, Marco; Varani, Elisabetta; Marzilli, Mario; Galli, Claudio; Heiman, Franca; Lavezzari, Maurizio; Stragliotto, Eduardo; De Caterina, Raffaele

    2002-06-01

    Previous trials of omega-3 fatty acids (omega-3 FA) for restenosis prevention after percutaneous transluminal coronary angioplasty (PTCA) have yielded conflicting results. We tested the hypothesis that long-term administration of omega-3 FA before PTCA may have significant effects on restenosis. We randomized 339 patients in a double-blind, placebo-controlled study of omega-3 FA (as an ethyl ester preparation given as 6 1-g capsules providing 3 g eicosapentaenoic acid and 2.1 g docosahexaenoic acid/d started 1 month before PTCA and given for 1 month thereafter, then continued at half-dose for 6 months) versus an olive oil placebo. Of these, 257 patients (125 on omega-3 FA, 132 on placebo) well matched for risk factors underwent successful balloon-only PTCA (280 total lesions) and were evaluable at 6 months with repeat angiography. Restenosis was defined at quantitative angiography as a recurrence of >50% diameter stenosis in the dilated vessel (Definition I) and as >50% loss of the short-term gain immediately after PTCA (Definition II). Restenosis rates per vessel were 29.4% and 31.6% in the omega-3 FA group, and 39.6% and 35.4% in the placebo group according to Definitions I (P =.04) and II (P = not significant), respectively. Restenosis rates per patient were 31.2% and 33.6% in the omega-3 FA group, and 40.9% and 37.1% in the placebo group according to Definitions I (P =.05) and II (P = not significant), respectively. With a long treatment before PTCA, omega-3 FA produced a small but significant decrease in the restenosis rate compared with placebo.

  13. Carotid angioplasty and stenting in the elderly

    International Nuclear Information System (INIS)

    Kadkhodayan, Yasha; Cross, DeWitte T.; Moran, Christopher J.; Derdeyn, Colin P.

    2007-01-01

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients ≤79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  14. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  15. Percutaneous stenting of the superior mesenteric artery for the treatment of chronic mesenteric ischemia

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Kim, Sam Soo

    2008-01-01

    We wanted to evaluate the effectiveness of stent placement on the superior mesenteric artery as a treatment for chronic mesenteric ischemia. Seven patients (mean age: 55 years, age range: 43-66 years) with chronic mesenteric ischemia were enrolled between March 2000 and September 2003. All the patients underwent pre-procedure contrast enhanced computerized tomography to evaluate for occlusion or stenosis of the mesenteric arteries and they then underwent an angiographic procedure. A balloon-expandable metal stent was placed in the superior mesenteric artery, and this was combined with balloon angioplasty and thrombolysis. We evaluated the angiographic and procedural success after the procedures. Angiographic and procedural success was obtained in 100% of the patients and the clinical symptoms improved in 100% of the patients. The patency at 6-months and 1-year was 85% and 71%, respectively. The mean follow-up period was 12 months (range: 1-25 months). During the follow-up period, ischemic symptoms recurred in 2 patients, and restenosis in a stent was confirmed with angiography; one patient was successfully treated by stent placement in the celiac artery and the other patient died due to extensive mesenteric thrombosis. For the treatment of chronic mesenteric ischemia, percutaneous stent placement on the superior mesenteric artery showed a favorable result and it was an effective alternative to surgery for the high-risk patients

  16. Paclitaxel-eluting versus sirolimus-eluting stents in diabetes mellitus: a report from the National Heart, Lung, and Blood Institute Dynamic Registry.

    Science.gov (United States)

    Wolf, William M; Vlachos, Helen A; Marroquin, Oscar C; Lee, Joon S; Smith, Conrad; Anderson, William D; Schindler, John T; Holper, Elizabeth M; Abbott, J Dawn; Williams, David O; Laskey, Warren K; Kip, Kevin E; Kelsey, Sheryl F; Mulukutla, Suresh R

    2010-02-01

    Diabetes is a powerful predictor of adverse events in patients undergoing percutaneous coronary intervention. Drug-eluting stents reduce restenosis rates compared with bare metal stents; however, controversy remains regarding which drug-eluting stents provides greater benefit in patients with diabetes. Accordingly, we compared the safety and efficacy of sirolimus-eluting stents (SES) with paclitaxel-eluting stents (PES) among diabetic patients in a contemporary registry. Using the National Heart, Lung, and Blood Institute Dynamic Registry, we evaluated 2-year outcomes of diabetic patients undergoing percutaneous coronary interventions with SES (n=677) and PES (n=328). Clinical and demographic characteristics, including age, body mass index, insulin use, left ventricular function, and aspirin/clopidogrel use postprocedure, did not differ significantly between the groups except that PES-treated patients had a greater frequency of hypertension and hyperlipidemia. At the 2-year follow-up, no significant differences were observed between PES and SES with regard to safety or efficacy end points. PES- and SES-treated patients had similar rates of death (10.7% versus 8.2%, P=0.20), death and myocardial infarction (14.9% versus 13.6%, P=0.55), repeat revascularization (14.8% versus 17.8%, P=0.36), and stent thrombosis (1.3% versus 1.3%, P=0.95). After adjustment, no significant differences between the 2 stent types in any outcome were observed. PES and SES are equally efficacious and have similar safety profiles in diabetic patients undergoing percutaneous coronary interventions in clinical practice.

  17. Effect of 125I seeds and 103Pd stents on proliferation of vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Zhu Jun; Zhu Ruisen

    2004-01-01

    To establish the theoretical and practical base for implementing radioactive stents aft PTCA in order to prevent restenosis, in vitro observation was taken over the effects of 12 '5I-seeds and 103 Pd-implanted stents on the vascular smooth muscle cell (VSMC) proliferation. In vitro VSMC model from guinea-pig aortic arteries was established using adherent cell culture methods. The effects of 125 I-seeds and 103 Pd-implanted stents on the VSMC proliferation, with or without fetal bovine serum (FCS), were investigated through cell counting methods and 3 H-TDR implementation tests. It was shown that (1) 10% FCS significantly promoted the DNA synthesis of VSMC (P 125 I-seeds and 103 Pd-implanted stents inhibited the VSMC DNA synthesis in dose-dependent manner, regardless of 10% FCS inducement. At lower radioactive doses, neither 125 I-seeds (18.5-74 kBq) nor 103 Pd-implanted stents (1.48-2.96 MBq) exhibited distinctive effects on the VSMC DNA synthesis (P>0.05); and (3) 48 hour exposure from 125 I-seeds at 128 kBq or 10 '3Pd-implanted stents at 7.4 MBq did not result in VSMC morphological alteration, but 125 I-seeds at 370 kBq caused cells' morphological changes. Therefore both 125 I-seeds and 103 Pd-implanted stents inhibit the in vitro VSMC DNA synthesis, and the inhibition effects are significantly related to their exposure duration and doses. (authors)

  18. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    Science.gov (United States)

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as

  19. Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents

    Science.gov (United States)

    Bowen, Patrick K.; Guillory, Roger J.; Shearier, Emily R.; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-01-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells. PMID:26249616

  20. Intraoperative and postoperative feasibility and safety of total tubeless, tubeless, small-bore tube, and standard percutaneous nephrolithotomy: a systematic review and network meta-analysis of 16 randomized controlled trials.

    Science.gov (United States)

    Lee, Joo Yong; Jeh, Seong Uk; Kim, Man Deuk; Kang, Dong Hyuk; Kwon, Jong Kyou; Ham, Won Sik; Choi, Young Deuk; Cho, Kang Su

    2017-06-27

    Percutaneous nephrolithotomy (PCNL) is performed to treat relatively large renal stones. Recent publications indicate that tubeless and total tubeless (stentless) PCNL is safe in selected patients. We performed a systematic review and network meta-analysis to evaluate the feasibility and safety of different PCNL procedures, including total tubeless, tubeless with stent, small-bore tube, and large-bore tube PCNLs. PubMed, Cochrane Central Register of Controlled Trials, and EMBASE™ databases were searched to identify randomized controlled trials published before December 30, 2013. One researcher examined all titles and abstracts found by the searches. Two investigators independently evaluated the full-text articles to determine whether those met the inclusion criteria. Qualities of included studies were rated with Cochrane's risk-of-bias assessment tool. Sixteen studies were included in the final syntheses including pairwise and network meta-analyses. Operation time, pain scores, and transfusion rates were not significantly different between PCNL procedures. Network meta-analyses demonstrated that for hemoglobin changes, total tubeless PCNL may be superior to standard PCNL (mean difference [MD] 0.65, 95% CI 0.14-1.13) and tubeless PCNLs with stent (MD -1.14, 95% CI -1.65--0.62), and small-bore PCNL may be superior to tubeless PCNL with stent (MD 1.30, 95% CI 0.27-2.26). Network meta-analyses also showed that for length of hospital stay, total tubeless (MD 1.33, 95% CI 0.23-2.43) and tubeless PCNLs with stent (MD 0.99, 95% CI 0.19-1.79) may be superior to standard PCNL. In rank probability tests, small-bore tube and total tubeless PCNLs were superior for operation time, pain scores, and hemoglobin changes. For hemoglobin changes, total tubeless and small-bore PCNLs may be superior to other methods. For hospital stay, total tubeless and tubeless PCNLs with stent may be superior to other procedures.

  1. Comparison of Long-Term Clinical Outcomes of Lesions Exhibiting Focal and Segmental Peri-Stent Contrast Staining.

    Science.gov (United States)

    Tokuda, Takahiro; Yamawaki, Masahiro; Takahara, Mitsuyohi; Mori, Shinsuke; Makino, Kenji; Honda, Yosuke; Takafuji, Hiroya; Takama, Takuro; Tsutsumi, Masakazu; Sakamoto, Yasunari; Takimura, Hideyuki; Kobayashi, Norihiro; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki

    2016-03-18

    Peri-stent contrast staining (PSS) after metallic drug-eluting stent deployment is associated with target lesion revascularization and very late stent thrombosis. However, the type of PSS that influences the clinical outcomes is unknown. Therefore, we aimed to reveal which PSS type was influencing clinical outcomes. This study included 5580 de novo lesions of 4405 patients who were implanted with a first- or second-generation drug-eluting stent and who were evaluated using follow-up angiography within 12 months after stent implantation. We compared the clinical outcomes of patients divided into focal PSS and segmental PSS groups for 6 years after stent implantation. Total PSS was observed in 97 lesions (2.2%), of which 42 and 55 lesions were focal and segmental PSS, respectively. Baseline characteristics were similar between groups, except for intraoperative chronic total occlusion (segmental PSS=47.3% versus focal PSS=11.9%, P=0.0001). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent (83.6% versus 16.4%, P=0.05). The cumulative incidence of stent thrombosis in the 6 years of segmental PSS group was significantly higher than that of the focal PSS group (13.9% versus 0%, P=0.04). The cumulative incidence of overall target lesion revascularization for restenosis, excluding target lesion revascularization procedures for stent thrombosis, was significantly higher in the segmental PSS group (38.0% versus 0%, P=0.01). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent and appeared to be significantly associated with target lesion revascularization and stent thrombosis. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Acute hemifacial ischemia as a late complication of carotid stenting

    Directory of Open Access Journals (Sweden)

    Maurizio Domanin, MD

    2017-06-01

    Full Text Available Concerns about carotid artery stenting (CAS center primarily on procedural complications like acute occlusion, stroke, and long-term intrastent restenosis. External carotid artery (ECA thrombosis is observed during CAS follow-up, but it often remains asymptomatic or, at worst, results in jaw claudication. We report here a case of late occlusion of the ECA after CAS with symptoms of acute homolateral facial ischemia as well as pain, cyanosis, tongue numbness, and skin coldness. The patient was submitted to local thrombolysis and balloon angioplasty with regression of symptoms after recanalization. With this report, we add a caveat about blockage of the ECA ostium during CAS.

  3. Propensity score matched lesion-based comparison of long-term clinical and angiographic outcomes after placement of sirolimus (Cypher Bx Velocity) and paclitaxel (TAXUS Express)-eluting stents for de novo native coronary stenosis.

    Science.gov (United States)

    Nakano, Yosuke; Ishikawa, Tetsuya; Hino, Shoryoku; Mutoh, Makoto

    2014-04-01

    Long-term clinical and angiographic outcomes after sirolimus (SES: Cypher Bx Velocity) and paclitaxel (PES: TAXUS Express)-eluting stent implantation were firstly compared in Japan. During PES-available period from May 2007 to February 2009, 1068 nonrandomized consecutive de novo native coronary lesions treated either with a PES (682 lesions) or SES were enrolled in this study, and a retrospective examination was conducted in April 2013. During that interval, the use ratio of drug-eluting stent (i.e. SES plus PES) was 94.2 %. By adjusting the baselines with a propensity score matching analysis produced 383 lesions in each arm, the incidence of the clinical endpoint (1500-day cardiac death, nonfatal recurrent myocardial infarction, and definite stent thrombosis) after placement of SES (2.1 %; mean follow-up, 1400 ± 290 days) was not significantly different from that in the PES group (2.6 %; 1394 ± 325 days, p = 0.637). SES did not relate to the clinical endpoint (hazard ratio 1.04; 95 % CI 0.29-3.76; p = 0.949). In the baseline-adjusted angiographic followed up lesions (n = 234 in each arm), the incidence of binary restenosis (percent diameter stenosis [%DS] >50 %) in the SES group (12.0 %; mean follow-up, 477 ± 281 days) was not significantly different from that in the PES group (14.5 %; 497 ± 341 days, p = 0.431). SES did not relate to binary restenosis (Odds ratio 0.73; 95 % CI 0.40-1.32; p = 0.295). In conclusion, the present propensity score matched lesion-based analysis firstly showed the statistical equivalent long-term clinical and angiographic outcomes after either SES or PES placement for de novo native coronary lesion in Japanese patients in a daily practice environment.

  4. Meta-analysis with R

    CERN Document Server

    Schwarzer, Guido; Rücker, Gerta

    2015-01-01

    This book provides a comprehensive introduction to performing meta-analysis using the statistical software R. It is intended for quantitative researchers and students in the medical and social sciences who wish to learn how to perform meta-analysis with R. As such, the book introduces the key concepts and models used in meta-analysis. It also includes chapters on the following advanced topics: publication bias and small study effects; missing data; multivariate meta-analysis, network meta-analysis; and meta-analysis of diagnostic studies.  .

  5. Trial Sequential Analysis in systematic reviews with meta-analysis

    Directory of Open Access Journals (Sweden)

    Jørn Wetterslev

    2017-03-01

    Full Text Available Abstract Background Most meta-analyses in systematic reviews, including Cochrane ones, do not have sufficient statistical power to detect or refute even large intervention effects. This is why a meta-analysis ought to be regarded as an interim analysis on its way towards a required information size. The results of the meta-analyses should relate the total number of randomised participants to the estimated required meta-analytic information size accounting for statistical diversity. When the number of participants and the corresponding number of trials in a meta-analysis are insufficient, the use of the traditional 95% confidence interval or the 5% statistical significance threshold will lead to too many false positive conclusions (type I errors and too many false negative conclusions (type II errors. Methods We developed a methodology for interpreting meta-analysis results, using generally accepted, valid evidence on how to adjust thresholds for significance in randomised clinical trials when the required sample size has not been reached. Results The Lan-DeMets trial sequential monitoring boundaries in Trial Sequential Analysis offer adjusted confidence intervals and restricted thresholds for statistical significance when the diversity-adjusted required information size and the corresponding number of required trials for the meta-analysis have not been reached. Trial Sequential Analysis provides a frequentistic approach to control both type I and type II errors. We define the required information size and the corresponding number of required trials in a meta-analysis and the diversity (D2 measure of heterogeneity. We explain the reasons for using Trial Sequential Analysis of meta-analysis when the actual information size fails to reach the required information size. We present examples drawn from traditional meta-analyses using unadjusted naïve 95% confidence intervals and 5% thresholds for statistical significance. Spurious conclusions in

  6. Restenosis: A Challenge to Angioplasty

    Indian Academy of Sciences (India)

    Smooth muscle cells from the internal elastic membrane and ... atherosclerosis. In addition to LDL other risk factors for athero- ... The present management of restenosis is ... lumen, while the control artery had developed stenosis (Figure 5).

  7. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  8. Effect of oral sirolimus therapy on inflammatory biomarkers following coronary stenting

    Directory of Open Access Journals (Sweden)

    W.C.M. Rosa

    2010-08-01

    Full Text Available We studied the effect of oral sirolimus, administered to prevent and treat in-stent restenosis (ISR, on the variation of serum levels of inflammatory markers following coronary stenting with bare metal stents. The mean age of the patients was 56 ± 13 years, 65% were males and all had clinically manifested ischemia. Serum levels of high sensitivity C-reactive protein (hs-CRP concentration were determined by chemiluminescence and serum levels of all other biomarkers by ELISA. One group of patients at high risk for ISR received a loading oral dose of 15 mg sirolimus and 5 mg daily thereafter for 28 days after stenting (SIR-G. A control group (CONT-G was submitted to stenting without sirolimus therapy. The increase in hs-CRP concentration was highest at 24 h after stenting in both groups. A significant difference between SIR-G and CONT-G was observed at 4 weeks (-1.50 ± 5.0 vs -0.19 ± 0.4, P = 0.008 and lost significance 1 month after sirolimus discontinuation (-1.73 ± 4.3 vs -0.01 ± 0.7, P = 0.0975. A continuous fall in MMP-9 concentration was observed in SIR-G, with the greatest reduction at 4 weeks (-352.9 ± 455 vs +395.2 ± 377, P = 0.0004, while a positive variation was noted 4 weeks after sirolimus discontinuation (227 ± 708 vs 406.2 ± 472.1, P = 0.0958. SIR-G exhibited a higher increase in P-selectin after sirolimus discontinuation at week 8 (46.1 ± 67.9 vs 5.8 ± 23.7, P = 0.0025. These findings suggest that the anti-restenotic actions of systemic sirolimus include anti-proliferative effects and modulation of the inflammatory response with inhibition of adhesion molecule expression.

  9. Primary antegrade ureteric stenting: Prospective experience and cost-effectiveness analysis in 50 ureters

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Gillian M.T.; Patel, Uday

    2001-07-01

    AIM: To evaluate the success rate and cost efficiency of primary antegrade ureteric stenting (antegrade ureteric stent insertion as a single procedure without preliminary drainage). MATERIALS AND METHODS: A policy of primary stenting was tested in 38 patients (50 ureters) with obstructive hydronephrosis, of acute or chronic onset and of benign or malignant origin. Patients with suspected pyonephrosis were excluded. Patients successfully primarily stented (group 1) were compared to a group stented as a traditional two-stage procedure (group 2). End point assessments were screening time, equipment used, procedure-related costs, bed occupancy and technical and clinical success rate. Using these cost and outcome measures, a cost-efficiency analysis was performed comparing the two strategies. RESULTS: 40/50 (80%) ureters were considered primary stent successes. The average procedure-related bed occupancy was 2 days (range 1-2 days). Simple equipment alone was successful in 16 cases. Van Andel dilatation catheters and peel-away sheaths were frequently used (23 ureters). Expensive equipment was rarely necessary (four cases) and average extra equipment cost was small (46 pounds/case). The mean screening time was similar for the two groups (13.5 min vs 15.3 min;P {>=} 0.05). There was a minimum saving of 800 pounds per successful primary stent. The cost-effectiveness of a primary antegrade stenting strategy was 1229 pounds vs 2093 pounds for secondary stenting. CONCLUSION: In carefully selected patients, the majority of obstructed ureters can be primarily stented using simple equipment. The reduced hospital stay and overall success rate significantly improves the cost competitiveness of antegrade ureteric stenting. Watson, G.M.T. and Patel, U. (2001)

  10. Self-expanding Y stents in the treatment of central airway stenosis: a retrospective analysis.

    Science.gov (United States)

    Gompelmann, Daniela; Eberhardt, Ralf; Schuhmann, Maren; Heussel, Claus P; Herth, Felix J F

    2013-10-01

    Central airway obstruction (CAO) is a life-threatening situation. Stent insertion re-establishes patency of the central airways. Self-expanding metallic Y stents have been available since 2005, widening the spectrum of interventional bronchoscopic techniques. Retrospective analysis of all patients treated for CAO with a self-expanding metallic Y stent at the Thoraxklinik Heidelberg between May 2005 and January 2009. A total of 43 patients aged 26-81 had a metallic Y stent inserted endoscopically for the treatment of CAO; 39 of these patients (90.7%) had CAO due to malignant disease, four patients (9.3%) due to benign disease. In all 43 patients, the Y stent was deployed without any complications. A longitudinal follow up was possible in 32 of the 43 patients. The stents remained in situ for an average of 107.1 days (range 1-640 days). In 29 patients with malignant CAO the stenosis was successfully overcome with a Y stent; 11 of these patients died within 6 weeks following stent insertion. On follow up the remaining 18 patients showed immediate improvement of dyspnoea. Eight out of the 18 patients (44.4%) tolerated the stent without problems, two (11.1%) required further stenting, six (33.3%) had complications such as increased secretions, cough, dyspnoea or granulation tissue formation. The stent was removed in one patient (5.6%) due to increased secretions, and in another (5.6%) as the stent was no longer required due to successful tumour-specific therapy. Placement of Y stents in symptomatic CAO allows for quick relief of symptoms. Severe complications are rare. Stent removal is possible after successful treatment of the primary tumour. However, the prognostic indicator for survival is the underlying malignancy.

  11. A Novel Self-Expandable, Radioactive Airway Stent Loaded with 125I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

    Science.gov (United States)

    Wang, Yong; Guo, Jin-He; Zhu, Guang-Yu; Zhu, Hai-Dong; Chen, Li; Lu, Jian; Wang, Chao; Teng, Gao-Jun

    2017-07-01

    Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with 125 I seeds in healthy beagle dog. Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with 125 I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting. All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of 125 I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope. This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with 125 I seeds in healthy beagle dog.

  12. Cost utility analysis of endoscopic biliary stent in unresectable hilar cholangiocarcinoma: decision analytic modeling approach.

    Science.gov (United States)

    Sangchan, Apichat; Chaiyakunapruk, Nathorn; Supakankunti, Siripen; Pugkhem, Ake; Mairiang, Pisaln

    2014-01-01

    Endoscopic biliary drainage using metal and plastic stent in unresectable hilar cholangiocarcinoma (HCA) is widely used but little is known about their cost-effectiveness. This study evaluated the cost-utility of endoscopic metal and plastic stent drainage in unresectable complex, Bismuth type II-IV, HCA patients. Decision analytic model, Markov model, was used to evaluate cost and quality-adjusted life year (QALY) of endoscopic biliary drainage in unresectable HCA. Costs of treatment and utilities of each Markov state were retrieved from hospital charges and unresectable HCA patients from tertiary care hospital in Thailand, respectively. Transition probabilities were derived from international literature. Base case analyses and sensitivity analyses were performed. Under the base-case analysis, metal stent is more effective but more expensive than plastic stent. An incremental cost per additional QALY gained is 192,650 baht (US$ 6,318). From probabilistic sensitivity analysis, at the willingness to pay threshold of one and three times GDP per capita or 158,000 baht (US$ 5,182) and 474,000 baht (US$ 15,546), the probability of metal stent being cost-effective is 26.4% and 99.8%, respectively. Based on the WHO recommendation regarding the cost-effectiveness threshold criteria, endoscopic metal stent drainage is cost-effective compared to plastic stent in unresectable complex HCA.

  13. Living network meta-analysis compared with pairwise meta-analysis in comparative effectiveness research: empirical study

    Science.gov (United States)

    Nikolakopoulou, Adriani; Mavridis, Dimitris; Furukawa, Toshi A; Cipriani, Andrea; Tricco, Andrea C; Straus, Sharon E; Siontis, George C M; Egger, Matthias

    2018-01-01

    Abstract Objective To examine whether the continuous updating of networks of prospectively planned randomised controlled trials (RCTs) (“living” network meta-analysis) provides strong evidence against the null hypothesis in comparative effectiveness of medical interventions earlier than the updating of conventional, pairwise meta-analysis. Design Empirical study of the accumulating evidence about the comparative effectiveness of clinical interventions. Data sources Database of network meta-analyses of RCTs identified through searches of Medline, Embase, and the Cochrane Database of Systematic Reviews until 14 April 2015. Eligibility criteria for study selection Network meta-analyses published after January 2012 that compared at least five treatments and included at least 20 RCTs. Clinical experts were asked to identify in each network the treatment comparison of greatest clinical interest. Comparisons were excluded for which direct and indirect evidence disagreed, based on side, or node, splitting test (Pmeta-analysis. The frequency and time to strong evidence was compared against the null hypothesis between pairwise and network meta-analyses. Results 49 comparisons of interest from 44 networks were included; most (n=39, 80%) were between active drugs, mainly from the specialties of cardiology, endocrinology, psychiatry, and rheumatology. 29 comparisons were informed by both direct and indirect evidence (59%), 13 by indirect evidence (27%), and 7 by direct evidence (14%). Both network and pairwise meta-analysis provided strong evidence against the null hypothesis for seven comparisons, but for an additional 10 comparisons only network meta-analysis provided strong evidence against the null hypothesis (P=0.002). The median time to strong evidence against the null hypothesis was 19 years with living network meta-analysis and 23 years with living pairwise meta-analysis (hazard ratio 2.78, 95% confidence interval 1.00 to 7.72, P=0.05). Studies directly comparing

  14. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  15. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  16. Improved outcome with novel device for low-pressure PTCA in de novo and in-stent lesions

    International Nuclear Information System (INIS)

    Ischinger, Thomas A.; Solar, Ronald J.; Hitzke, Evelyn

    2003-01-01

    Purpose: Complex lesion morphology requiring the use of high pressure to effect lumen expansion and in-stent restenosis (ISR) remain two indications that challenge conventional PTCA balloons. We report on a new PTCA device that is designed to provide precise, low-pressure dilatation of both de novo and in-stent lesions. Methods: The FX miniRAIL catheter (FX) has an integral wire positioned external to a dilating balloon and a short, 12-mm guidewire lumen distal to the balloon. The balloon inflates against the guidewire and the external wire to prevent slippage and to introduce high focal longitudinal stresses at low inflation pressures. In this initial study, the FX was used in 37 lesions (25 de novo, 12 in-stent; vessel reference diameter=2.73±0.49 mm) in 30 patients. A stepwise inflation protocol and QCA were used to determine the balloon pressure at which the stenosis was resolved (stenosis resolution pressure, SRP). Results: All lesions (100%) were easily reached, crossed and dilated without complication. The SRP was 4.5±2.9 atm, and no balloon slippage was observed. Residual stenosis after FX was 26.39±13.29%. Minor dissections (Types A and B) were observed in eight lesions (21.6%). Target lesion revascularization (TLR) and target vessel revascularization (TVR) at follow-up (8.1±1.5 months) were 8.3% and 12.5%, respectively. Conclusion: The design of the FX is versatile and appears to provide for a safe, effective and improved low-pressure PTCA technique in de novo and in-stent lesions

  17. Experimental study of an endothelial progenitor cell coated stent in transjugular intrahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Shi Hongjian; Teng Gaojun; Cao Aihong; Chen Jun; Deng Gang

    2009-01-01

    Objective: To evaluate the efficacy of a self-expandable metal stent coated with autologous endothelial progenitor cells (EPCs) for prevention of restenosis in transjugular intrahepatic portosystemic shunt (TIPS) in a swine model. Methods: EPCs were coated on the metal stents using fibrin gel before TIPS procedure. TIPS was performed in 15 young adult pigs, using an autologous EPC-seeded stent (treatment group, n=9) or a conventional bare metal stent (control group, n=6). All pigs were sacrificed at 2 weeks after TIPS procedure. Portography was performed immediately before the euthanasia. Gross and microscopic pathological exams and immunohistochemical exams of the TIPS track specimens were performed. Fisher test and t test were used to analyse the data. Results: TIPS was performed successfully in all the 15 swine. On day 14 of follow-up, direct portography and necropsy demonstrated that 5 shunts remained patent, 2 shunts stenosed, and the remaining 2 shunts occluded in the treatment group (n=9); while 5 shunts were occluded and one shunt was stenotic in the control group (n=6). The patency rate was 56% vs 0 (P=0.03) between the two groups. Histological analyses showed a greater pseudo-intimal hyperplasia in the TIPS track of the control group than that of the treatment group (pseudointimal thickness at hepatic vein, hepatic parenchyma and portal vein site was (1.2±0.4), (1.3±0.5), (1.5±0.4) mm vs (1.0±0.6), (0.9±0.5), (1.0±0.4) mm respectively (P<0.05). Conclusion: The EPC-coated metal stent is feasibly constructed in vitro and improves the patency in TIPS in a porcine model. (authors)

  18. The (PrS/HGF-pDNA) multilayer films for gene-eluting stent coating: Gene-protecting, anticoagulation, antibacterial properties, and in vivo antirestenosis evaluation.

    Science.gov (United States)

    Chang, Hao; Ren, Ke-feng; Zhang, He; Wang, Jin-lei; Wang, Bai-liang; Ji, Jian

    2015-02-01

    Vascular gene-eluting stents (GES) is a promising strategy for treatment of cardiovascular disease. Very recently, we have proved that the (protamine sulfate/plasmid DNA encoding hepatocyte growth factor) (PrS/HGF-pDNA) multilayer can serve as a powerful tool for enhancing competitiveness of endothelial cell over smooth muscle cell, which opens perspectives for the regulation of intercellular competitiveness in the field of interventional therapy. However, before the gene multilayer films could be used in vascular stents for real clinical application, the preservation of gene bioactivity during the industrial sterilization and the hemocompatibility of film should be taken into account. Actually, both are long been ignored issues in the field of gene coating for GES. In this study, we demonstrate that the (PrS/HGF-pDNA) multilayer film exhibits the good gene-protecting abilities, which is confirmed by using the industrial sterilizations (gamma irradiation and ethylene oxide) and a routine storage condition (dry state at 4°C for 30 days). Furthermore, hemocompatible measurements (such as platelet adhesion and whole blood coagulation) and antibacterial assays (bacteria adhesion and growth inhibition) indicate the good anticoagulation and antibacterial properties of the (PrS/HGF-pDNA) multilayer film. The in vivo preliminary data of angiography and histological analysis suggest that the (PrS/HGF-pDNA) multilayer coated stent can reduce the in-stent restenosis. This work reveals that the (PrS/HGF-pDNA) multilayer film could be a promising candidate as coating for GES, which is of great potential in future clinic application. © 2014 Wiley Periodicals, Inc.

  19. Intravascular local gene transfer mediated by protein-coated metallic stent.

    Science.gov (United States)

    Yuan, J; Gao, R; Shi, R; Song, L; Tang, J; Li, Y; Tang, C; Meng, L; Yuan, W; Chen, Z

    2001-10-01

    To assess the feasibility, efficiency and selectivity of adenovirus-mediated gene transfer to local arterial wall by protein-coated metallic stent. A replication-defective recombinant adenovirus carrying the Lac Z reporter gene for nuclear-specific beta-galactosidase (Ad-beta gal) was used in this study. The coating for metallic stent was made by immersing it in a gelatin solution containing crosslinker. The coated stents were mounted on a 4.0 or 3.0 mm percutaneous transluminal coronary angioplasty (PTCA) balloon and submersed into a high-titer Ad-beta gal viral stock (2 x 10(10) pfu/ml) for 3 min, and then implanted into the carotid arteries in 4 mini-swines and into the left anterior descending branch of the coronary artery in 2 mini-swines via 8F large lumen guiding catheters. The animals were sacrificed 7 (n = 4), 14 (n = 1) and 21 (n = 1) days after implantation, respectively. The beta-galactosidase expression was assessed by X-gal staining. The results showed that the expression of transgene was detected in all animal. In 1 of carotid artery with an intact intima, the beta-gal expression was limited to endothelial cells. In vessels with denuded endothelium, gene expression was found in the sub-intima, media and adventitia. The transfection efficiency of medial smooth muscle cells was 38.6%. In 2 animals sacrificed 7 days after transfection, a microscopic examination of X-gal-stained samples did not show evidence of transfection in remote organs and arterial segments adjacent to the treated arterial site. Adenovirus-mediated arterial gene transfer to endothelial, smooth muscle cells and adventitia by protein-coated metallic stent is feasible. The transfection efficiency is higher. The coated stent may act as a good carrier of adenovirus-mediated gene transfer and have a potential to prevent restenosis following PTCA.

  20. Application of the Enterprise Stent in Atherosclerotic Intracranial Arterial Stenosis: A Series of 60 Cases.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Wang, Chengwei; Ji, Yong; Ding, Xuan; Zang, Yizheng

    2016-01-01

    We assessed the safety and effectiveness of the Enterprise stent in treating atherosclerotic intracranial arterial stenosis (AIAS). This was a retrospective study conducted with 60 consecutive patients with 62 AIAS lesions who received the Enterprise stent at the Department of Neurosurgery, Second Hospital of Shandong University between June 2012 and January 2014. All patients were assessed using the modified Rankin scoring system at discharge. Clinical follow-ups and digital subtraction angiography (DSA) were performed at 1, 3, 6 and 12 months postoperatively. There were 42 men and 18 women with a mean age of 56.8 ± 8.0 years. Fourteen lesions (22.6%) were at the anterior and 48 (77.4 %) were at the posterior circulation. The mean stenosis rate was 76.3 ± 12.7%. The mean stenotic vessel length was 7.7 ± 2.0 mm. The technical success rate was 100%. The mean post-stent residual stenosis rate was 22.8 ± 4.8%. Five patients (8.3%) had perioperative complications, but no disability or mortality occurred within 30 days. The mean follow-up duration was 6.2 months. DSA was used to evaluate 45 lesions (72.6%) six months postoperatively: 6 (13.3%) had postoperative restenoses, 2 at the anterior circulation, and 4 at the posterior circulation. Of these 6, 4 (66.7%) were immediate residual stenoses after stenting. The residual stenosis rate was identified as a risk factor for restenosis. Five (8.3%) ischemic events, consistent with the vascular lesions, occurred. Application of the Enterprise stent was safe and efficacious. The technical success rate was high while the perioperative complication rate was low.

  1. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease: A Meta-Analysis of Individual Patient Data.

    Science.gov (United States)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung

    2016-12-26

    The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly pronounced in those with multivessel CAD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  2. Long term outcomes of new generation drug eluting stents versus coronary artery bypass grafting for multivessel and/or left main coronary artery disease. A Bayesian network meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Mina, George S; Watti, Hussam; Soliman, Demiana; Shewale, Anand; Atkins, Jessica; Reddy, Pratap; Dominic, Paari

    2018-01-05

    Most data guiding revascularization of multivessel disease (MVD) and/or left main disease (LMD) favor coronary artery bypass grafting (CABG) over percutaneous coronary intervention (PCI). However, those data are based on trials comparing CABG to bare metal stents (BMS) or old generation drug eluting stents (OG-DES). Hence, it is essential to outcomes of CABG to those of new generation drug eluting stents (NG-DES). We searched PUBMED and Cochrane database for trials evaluating revascularization of MVD and/or LMD with CABG and/or PCI. A Bayesian network meta-analysis was performed to calculate odds ratios (OR) and 95% credible intervals (CrI). Primary outcome was major adverse cardiovascular events (MACE) at 3-5 years. Secondary outcomes were mortality, cerebrovascular accidents (CVA), myocardial infarction (MI) and repeat revascularization. We included 10 trials with a total of 9287 patients. CABG was associated with lower MACE when compared to BMS or OG-DES. However, MACE was not significantly different between CABG and NG-DES (OR 0.79, CrI 0.45-1.40). Moreover, there were no significant differences between CABG and NG-DES in mortality (OR 0.78, CrI 0.45-1.37), CVA (OR 0.93 CrI 0.35-2.2) or MI (OR 0.6, CrI 0.17-2.0). On the other hand, CABG was associated with lower repeat revascularization (OR 0.55, CrI 0.36-0.84). Our study suggests that NG-DES is an acceptable alternative to CABG in patients with MVD and/or LMD. However, repeat revascularization remains to be lower with CABG than with PCI. Copyright © 2018. Published by Elsevier Inc.

  3. [Comparison of DK crush with classical crush technique with drug-eluting stents for the treatment of coronary bifurcation lesions from DKCRUSH-1 study].

    Science.gov (United States)

    Chen, Shao-liang; Zhang, Jun-jie; Ye, Fei; Chen, Yun-dai; Lü, Shu-zheng; Tan, Huaycheem; Patel, Tejas; Kenji, Kawajiri; Tamari, Israel; Shan, Shou-jie; Zhu, Zhong-sheng; Lin, Song; Tian, Nai-liang; Li, Xiao-bo; Liu, Zhi-zhong; Lee, Michael; Wei, Meng; Xu, Ya-wei; Yuan, Zheng-bai; Qian, Jun; Sun, Xue-wen; Yang, Song; Chen, Jin-guo; He, Ben; Sumit, Suji

    2008-02-01

    To determine independent factors correlated with clinical effects of DK crush and classical crush technique with drug-eluting stents on bifurcation lesions. 311 patients with bifurcation lesions were randomized to classical (C, n = 156) or double kissing (DK) crush (n = 155) stent implantation group. The primary endpoints included major adverse cardiac events (MACE). Final kissing balloon inflation (FKBI) success rate was 76% in C and 100% in DK groups (P DK crush procedure was characterized by lower unsatisfactory FKBI rate (27.6% vs.6.3%, P DK groups (P = 0.01), respectively. Cumulative 8-month MACE was 35.9% in without-FKBI and 19.7% in with-FKBI sub-groups, and 11.4% in DK group (P = 0.02). The incidence of stent thrombosis was 3.2% in C group (5.1% without vs. 1.7% with FKBI) and 1.3% in DK group (P > 0.05). The predictive factors of MACE included minimal side branch stent lumen diameter and lack of DK crush technique. DK crush technique is an alternative of double stenting techniques in terms of improvement of restenosis and clinical outcomes.

  4. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  5. A randomized trial comparing primary angioplasty versus stent placement for symptomatic intracranial stenosis

    Science.gov (United States)

    Qureshi, Adnan I; Chaudhry, Saqib A; Siddiq, Farhan; Majidi, Shahram; Rodriguez, Gustavo J; Suri, M Fareed K

    2013-01-01

    Background: Both primary angioplasty alone and angioplasty with a self-expanding stent have been compared in non-randomized concurrent clinical studies that suggest equivalent results. However, there is no randomized trial that has compared the two procedures in patients with symptomatic high grade intracranial stenosis. Objective: The primary aim of the randomized trial was to compare the clinical and angiographic efficacy of primary angioplasty and angioplasty followed by stent placement in preventing restenosis, stroke, requirement for second treatment, and death in patients with symptomatic intracranial stenosis. Methods: The study prospectively evaluated efficacy and safety of the two existing neurointerventional techniques for treatment of moderate intracranial stenosis (stenosis ≥ 50%) with documented failure of medical treatment or severe stenosis (≥70%) with or without failure of medical treatment. Results: A total of 18 patients were recruited in the study (mean age [±SD] was 64.7 ± 15.1 years); out of these, 12 were men. Of these 18, 10 were treated with primary angioplasty and 8 were treated with angioplasty followed by self-expanding stent. The technical success rates of intracranial angioplasty and stent placements defined as ability to achieve <30% residual stenosis when assessed by immediate post-procedure angiography was 5 of 10 and 5 of 8 patients, respectively. The total fluoroscopic time (mean [±SD]) was lower in patients undergoing primary angioplasty 37 [±11] min versus those undergoing angioplasty followed by self-expanding stent 42 [±15] min, P = 0.4321. The stroke and death rate within 1 month was very low in both patient groups (1 of 10 versus 0 of 8 patients). One patient randomized to stent placement continued to have recurrent ischemic symptoms requiring another angioplasty in the vertebral artery on post-procedure Day 2. Conclusions: The trial suggests that a randomized trial comparing primary angioplasty to angioplasty

  6. Safety and Efficacy of Thoracic External Beam Radiotherapy After Airway Stenting in Malignant Airway Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Rochet, Nathalie, E-mail: nrochet@partners.org [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany); Hauswald, Henrik; Schmaus, Martina; Hensley, Frank [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany); Huber, Peter [Department of Radiotherapy, German Cancer Research Center, Heidelberg (Germany); Eberhardt, Ralf; Herth, Felix J. [Department of Pulmonology and Respiratory Care Medicine, Thoraxklinik at University of Heidelberg, Heidelberg (Germany); Debus, Juergen; Neuhof, Dirk [Department of Radiation Oncology, University of Heidelberg, Heidelberg (Germany)

    2012-05-01

    Purpose: We retrospectively evaluated the outcome and toxicity of external beam radiotherapy (EBRT) after airway stents were placed in patients treated for malignant airway obstruction. Methods and Materials: Between 2004 and 2009, we performed airway stenting followed by EBRT in 43 patients for symptomatic primary lung cancer (n = 31) or other thoracic malignancies (n = 12). The median time interval between stent placement and first irradiation was 14 days. A median total dose of 50 Gy was delivered. Sixty-seven percent of the patients had reduced performance status (Karnofsky performance score, {<=}70). Results: EBRT had to be stopped prematurely in 16 patients (37%), at a median total dose of 17 Gy, for various reasons. In this group of patients, the survival was poor, with a median overall survival (OS) of only 21 days. Twenty-seven patients (63%) completed radiotherapy as planned, with a median OS of 8.4 months. Fourteen of 43 patients (33%) developed at least one Common Terminology Criteria for Adverse Event of grade 3 to 5. The most common event was a malignant restenosis of the stent leading to asphyxia (n = 7), followed by fistula formation (n = 4), necrosis (n = 3), mediastinitis with abscess (n = 1), secondary nonmalignant airway stenosis (n = 1), and hemoptysis (n = 1). With the exception of one event, all events were associated with a local progression of the tumor. Conclusions: Although the long-term prognosis for patients with malignant airway obstruction is poor, airway stenting combined with EBRT offers a possible therapeutic option, achieving fast relief of acute respiratory distress with an associated antitumor effect, resulting in a potential survival benefit. However, due to local advanced tumor growth, increased rates of adverse events are to be expected, necessitating careful monitoring.

  7. Safety and Efficacy of Thoracic External Beam Radiotherapy After Airway Stenting in Malignant Airway Obstruction

    International Nuclear Information System (INIS)

    Rochet, Nathalie; Hauswald, Henrik; Schmaus, Martina; Hensley, Frank; Huber, Peter; Eberhardt, Ralf; Herth, Felix J.; Debus, Juergen; Neuhof, Dirk

    2012-01-01

    Purpose: We retrospectively evaluated the outcome and toxicity of external beam radiotherapy (EBRT) after airway stents were placed in patients treated for malignant airway obstruction. Methods and Materials: Between 2004 and 2009, we performed airway stenting followed by EBRT in 43 patients for symptomatic primary lung cancer (n = 31) or other thoracic malignancies (n = 12). The median time interval between stent placement and first irradiation was 14 days. A median total dose of 50 Gy was delivered. Sixty-seven percent of the patients had reduced performance status (Karnofsky performance score, ≤70). Results: EBRT had to be stopped prematurely in 16 patients (37%), at a median total dose of 17 Gy, for various reasons. In this group of patients, the survival was poor, with a median overall survival (OS) of only 21 days. Twenty-seven patients (63%) completed radiotherapy as planned, with a median OS of 8.4 months. Fourteen of 43 patients (33%) developed at least one Common Terminology Criteria for Adverse Event of grade 3 to 5. The most common event was a malignant restenosis of the stent leading to asphyxia (n = 7), followed by fistula formation (n = 4), necrosis (n = 3), mediastinitis with abscess (n = 1), secondary nonmalignant airway stenosis (n = 1), and hemoptysis (n = 1). With the exception of one event, all events were associated with a local progression of the tumor. Conclusions: Although the long-term prognosis for patients with malignant airway obstruction is poor, airway stenting combined with EBRT offers a possible therapeutic option, achieving fast relief of acute respiratory distress with an associated antitumor effect, resulting in a potential survival benefit. However, due to local advanced tumor growth, increased rates of adverse events are to be expected, necessitating careful monitoring.

  8. Impact of the use of antibodies anti endothelin 1 on the coronary arterial estenosis for hyperplasia secondary neo intimal to barotraumas with ball and Stent in porcines

    International Nuclear Information System (INIS)

    Pineda V, Mauricio; Maldonado, Luz A; Uribe, Ana Maria and others

    2003-01-01

    Coronary angioplasty (PTCA) is performed in about two million surgical procedures every year in the world, and coronary restenosis (CR) continues to be it's weakest point. There are four mechanisms involved in CR 1. Thrombosis, 2.elastic recoil, 3. Constrictive arterial remodeling; and 4. Intimal hyperplasia. The first three are managed with Stents, inhibitors of GP lib//iiia, antiagregants and anticoagulants. The fourth is believed to be the only responsible of post Stent CR. endothelin 1(ET1) produces cellular proliferation. Impact of the anti ET1 anti bodies by intra coronary injection, or generated by immune response at the subcutaneous (SC) application of ET1, on the NI growth in porcines, who have undergone barotrauma with Stent, is expected to be demonstrated. PTCA was performed in 12 pigs (36 arterial specimens). They were sacrificed after four weeks of follow up. Specimens were divided in three groups, previously randomized, resulting in 12 specimens a group. The placebo group received intracoronary infusion of saline solution immediately after the barotraumas. The second group received intracoronary infusion of AET1 antibodies and the third group received SC injection of ET1 fourteen days before the trauma. Segments were studied with IVUS and hystomotphometric analysis. Statistical analysis: it was performed by the student t in order to compare independent measures. Because of the small size of the groups, the Mann Whitney test was applied. A double tale analysis was performed in both cases. A significant reduction of the NI area was obtained both with the injection of AET1 Abs and ET1 SC (p 0.001) in the IVUS and the hystomotphometric analyses. AET1 antibodies seem to prevent the post Stent NI growth. There is no significant advantage between both forms of injection

  9. MetaEasy: A Meta-Analysis Add-In for Microsoft Excel

    Directory of Open Access Journals (Sweden)

    Evangelos Kontopantelis

    2009-04-01

    Full Text Available Meta-analysis is a statistical methodology that combines or integrates the results ofseveral independent clinical trials considered by the analyst to be `combinable' (Huque1988. However, completeness and user-friendliness are uncommon both in specialisedmeta-analysis software packages and in mainstream statistical packages that have to relyon user-written commands. We implemented the meta-analysis methodology in an Mi-crosoft Excel add-in which is freely available and incorporates more meta-analysis models(including the iterative maximum likelihood and prole likelihood than are usually avail-able, while paying particular attention to the user-friendliness of the package.

  10. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Living network meta-analysis compared with pairwise meta-analysis in comparative effectiveness research: empirical study.

    Science.gov (United States)

    Nikolakopoulou, Adriani; Mavridis, Dimitris; Furukawa, Toshi A; Cipriani, Andrea; Tricco, Andrea C; Straus, Sharon E; Siontis, George C M; Egger, Matthias; Salanti, Georgia

    2018-02-28

    To examine whether the continuous updating of networks of prospectively planned randomised controlled trials (RCTs) ("living" network meta-analysis) provides strong evidence against the null hypothesis in comparative effectiveness of medical interventions earlier than the updating of conventional, pairwise meta-analysis. Empirical study of the accumulating evidence about the comparative effectiveness of clinical interventions. Database of network meta-analyses of RCTs identified through searches of Medline, Embase, and the Cochrane Database of Systematic Reviews until 14 April 2015. Network meta-analyses published after January 2012 that compared at least five treatments and included at least 20 RCTs. Clinical experts were asked to identify in each network the treatment comparison of greatest clinical interest. Comparisons were excluded for which direct and indirect evidence disagreed, based on side, or node, splitting test (Pmeta-analyses were performed for each selected comparison. Monitoring boundaries of statistical significance were constructed and the evidence against the null hypothesis was considered to be strong when the monitoring boundaries were crossed. A significance level was defined as α=5%, power of 90% (β=10%), and an anticipated treatment effect to detect equal to the final estimate from the network meta-analysis. The frequency and time to strong evidence was compared against the null hypothesis between pairwise and network meta-analyses. 49 comparisons of interest from 44 networks were included; most (n=39, 80%) were between active drugs, mainly from the specialties of cardiology, endocrinology, psychiatry, and rheumatology. 29 comparisons were informed by both direct and indirect evidence (59%), 13 by indirect evidence (27%), and 7 by direct evidence (14%). Both network and pairwise meta-analysis provided strong evidence against the null hypothesis for seven comparisons, but for an additional 10 comparisons only network meta-analysis provided

  12. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  13. Application of Y-shaped, coated self-expandable metallic stents for anastomotic stenosis after gastrojejunostomy (Billroth II).

    Science.gov (United States)

    Li, Teng-Fei; Wu, Gang; Han, Xin-Wei; Shui, Shao-Feng; Ren, Jian-Zhuang; Li, Zhen; Ren, Ke-Wei

    2017-01-01

    Anastomotic stenosis is an infrequent but life-threatening complication after gastrojejunostomy (Billroth II). Tubular or single tubular stents have limited efficacy due to the particular anatomy. To assess the feasibility of a Y-shaped, fully-coated, self-expandable, metallic stent (SEMS) for anastomotic stenosis after gastrojejunostomy (Billroth II). Between January 2008 and August 2014, 14 patients (10 with gastric carcinoma and four with duodenal ulcers) had anastomotic stenoses following Billroth II reconstructions. Eight patients with gastric cancer had tumor recurrence near the anastomosis; two had benign strictures. The four duodenal ulcer patients had benign stenoses. An integrated Y-shaped, fully coated SEMS was designed to accord with the anatomy of residual gastrojejunal anastomotic strictures. Fourteen stents were inserted under fluoroscopic control. Follow-up was at 1, 3, 9, and 12 months, and then annually. All 14 stents were inserted successfully at the first attempt with a technical success rate of 100%. After stenting, abdominal symptoms resolved in all patients. All patients were followed up for 4-27 months (mean, 13.9 months). One of the eight recurrent cases died of multiple tumor metastases and liver failure after 7 months, without obstruction symptoms. In all six patients with benign anastomotic stenosis, the stents were removed successfully without complication and with no evidence of restenosis based on clinical evaluation and imaging. A Y-shaped, fully-coated SEMS proved to be a feasible and minimally invasive procedure for treating anastomotic stenosis after gastrojejunostomy (Billroth II). © The Foundation Acta Radiologica 2016.

  14. Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma.

    Science.gov (United States)

    Chung, Kwang Hyun; Lee, Sang Hyub; Park, Jin Myung; Lee, Jae Min; Ahn, Dong-Won; Ryu, Ji Kon; Kim, Yong-Tae

    2015-06-01

    The patency of self-expandable metallic stents (SEMS) is known to be better than plastic stents in the palliation of malignant biliary obstruction. However, data are scarce for obstructive jaundice caused by hepatocellular carcinoma (HCC). This study aimed to compare SEMSs and plastic stents for the palliation of obstructive jaundice in unresectable HCC. A total of 96 patients who underwent endoscopic retrograde biliary drainage with SEMSs or plastic stents were included in this retrospective analysis. The rate of successful biliary drainage, adverse events, stent patency duration, and patient survival were compared between the SEMS (n = 36) and plastic stent (n = 60) groups. The rate of successful biliary drainage was similar between the SEMS and plastic stent groups (25/36 [69.4 %] vs. 39/60 [65.0 %]; P = 0.655). Adverse events occurred in 6 patients (16.7 %) in the SEMS group and 13 patients (21.7 %) in the plastic stent group (P = 0.552). The median patency duration was also similar between the two groups (60 vs. 68 days; P = 0.396). The median patient survival was longer in the plastic stent group than in the SEMS group (123 vs. 48 days; P = 0.005). SEMSs were not superior to plastic stents for the palliation of malignant biliary obstruction in HCC with regard to successful drainage, stent patency, and adverse events. Patient survival was better in the plastic stent group. Given the lower cost, plastic stents could be a favorable option for malignant biliary obstruction caused by HCC. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Trial Sequential Analysis in systematic reviews with meta-analysis

    DEFF Research Database (Denmark)

    Wetterslev, Jørn; Jakobsen, Janus Christian; Gluud, Christian

    2017-01-01

    BACKGROUND: Most meta-analyses in systematic reviews, including Cochrane ones, do not have sufficient statistical power to detect or refute even large intervention effects. This is why a meta-analysis ought to be regarded as an interim analysis on its way towards a required information size...... from traditional meta-analyses using unadjusted naïve 95% confidence intervals and 5% thresholds for statistical significance. Spurious conclusions in systematic reviews with traditional meta-analyses can be reduced using Trial Sequential Analysis. Several empirical studies have demonstrated...

  16. Modification and Control of Wound Healing in Tracheobronchial Injuries Using Minimally Invasive Surgical Techniques and Biologic Growth Factors-CIC3

    National Research Council Canada - National Science Library

    Perkins, Jonathan

    1998-01-01

    .... Currently, metallic stents offer an adjunctive treatment in airway reconstruction. These stents have the capability of stabilizing the size of the airway lumen, while preventing surgical site restenosis...

  17. Evaluating the cost of therapy for restenosis: considerations for brachytherapy

    International Nuclear Information System (INIS)

    Weintraub, William S.

    1996-01-01

    Costs have become increasingly important in medicine in recent years as demand for services has outstripped readily available resources. Clinical microeconomics offers an approach to understanding cost and outcomes in an environment of economic scarcity. In this article the types of costs and methods for determining cost are presented. In addition, methods for assessing outcome and outcome in relation to cost are developed. Restenosis after coronary angioplasty is a prime example of a clinical problem requiring economic evaluation. This is because it results in little serious morbidity except for recurrent chest pain, but it has serious economic consequences which occur some time after the original angioplasty. This makes the economic assessment of restenosis complicated. The application of health care microeconomic principles to brachytherapy for restenosis in the coronary arteries is presented

  18. Evaluating the cost of therapy for restenosis: considerations for brachytherapy.

    Science.gov (United States)

    Weintraub, W S

    1996-11-01

    Costs have become increasingly important in medicine in recent years as demand for services has outstripped readily available resources. Clinical microeconomics offers an approach to understanding cost and outcomes in an environment of economic scarcity. In this article the types of costs and methods for determining cost are presented. In addition, methods for assessing outcome and outcome in relation to cost are developed. Restenosis after coronary angioplasty is a prime example of a clinical problem requiring economic evaluation. This is because it results in little serious morbidity except for recurrent chest pain, but it has serious economic consequences which occur some time after the original angioplasty. This makes the economic assessment of restenosis complicated. The application of health care microeconomic principles to brachytherapy for restenosis in the coronary arteries is presented.

  19. Expert consensus (SBC/SBHCI) on the use of drug-eluting stents: recommendations of the Brazilian society of interventional cardiology/ Brazilian society of cardiology for the Brazilian public single healthcare system.

    Science.gov (United States)

    Lima, Valter C; Mattos, Luiz Alberto P; Caramori, Paulo R A; Perin, Marco A; Mangione, José A; Machado, Bruno M; Coelho, Wilson M C; Bueno, Ronaldo R L

    2006-10-01

    The authors review percutaneous coronary intervention (PCI) evolution and its growing application in myocardial revascularization for patients with coronary heart disease in Brazil and worldwide. PCI was introduced in 1977 using only the catheter balloon. Limitations of this method (acute occlusion and coronary restenosis) led to the adoption of coronary stents and more recently the advent of drug-eluting stents2, which were developed to drastically reduce restenosis rates. These developments allowed the exponential growth of percutaneous coronary intervention (PCI) procedures in Brazil which have replaced many bypass surgery procedures and have become the gold standard for the majority of symptomatic patients suffering from coronary artery disease. The preference for this procedure gained new dimensions in 2000 when the Brazilian Public Healthcare System (SUS) began reimbursing for stent procedures. This measure exemplified the importance of the Public Healthcare System's participation in incorporating medical advances and offering a high standard of cardiovascular treatment to a large portion of the Brazilian population. It is emphasized that prevention of in-stent restenosis is complex due to its unpredictable and ubiquitous occurrence. Control of this condition improves quality of life and reduces the recurrence of angina pectoris, the need to perform new revascularization procedures and hospital readmissions. The overall success of the drug-eluting stents has proven to be reliable and consistent in overcoming restenosis and has some beneficial impact for all clinical and angiographic conditions. This paper discusses the adoption and criteria for the use of drug-eluting stents in other countries as well as the recommendations established by the Brazilian Society of Interventional Cardiology for their reimbursement by SUS. The incorporation of new healthcare technology involves two distinct stages. During the first stage, the product is registered with the

  20. Restenosis after balloon valvuloplasty in a dog with pulmonary stenosis.

    Science.gov (United States)

    Sunahara, Hiroshi; Fujii, Yoko; Sugimoto, Keisuke; Aoki, Takuma; Sugahara, Gou; Shirota, Kinji

    2015-01-01

    A two-month-old female Chihuahua was diagnosed as severe pulmonary valvular stenosis (PS). Although balloon valvuloplasty (BV) was successfully performed, restenosis was observed 19 months after the procedure. Euthanasia was chosen due to low output syndrome during the surgical repair attempted when the dog was 5 years old. Postmortem examination revealed markedly thickened pulmonary valve due to the increase of extracellular matrix which might be produced by increased α smooth muscle actin-positive myofibroblasts. The thickening of the valve was associated with restriction of the valve's motion, resulting in restenosis in the present case. This is the first case report documented histopathological and immunohistochemical findings of the restenotic pulmonary valve in dogs with PS after BV.

  1. Intracoronary irradiation: dose response for the prevention of restenosis in swine

    International Nuclear Information System (INIS)

    Weinberger, Judah; Amols, Howard; Ennis, Ronald D.; Schwartz, Allan; Wiedermann, Joseph G.; Marboe, Charles

    1996-01-01

    Purpose: Restenosis after percutaneous transluminal coronary angioplasty represents, in part, a proliferative response of vascular smooth muscle at the site of injury. We have previously shown that high-dose radiation (20 Gy), delivered via an intracoronary 192 Ir source, causes focal medial fibrosis and markedly impairs the restenosis process after balloon angioplasty in swine. This study sought to delineate the dose-response characteristics of this effect. Methods and Materials: Forty juvenile swine underwent coronary angiography; a segment of the left coronary artery was chosen as a target for balloon injury. In 30 swine, a 2 cm ribbon of 192 Ir was positioned at the target segment and 20, 15, or 10 Gy were delivered to the vessel wall (10 animals/dose). Subsequently, overdilatation balloon angioplasty was performed at the irradiated segment. In 10 control swine, overdilatation balloon angioplasty was performed without previous irradiation. Thirty-eight animals survived until sacrifice at 30 ± 3 days. Histopathological analysis was performed by a pathologist in a blinded manner. The area of maximal luminal compromise within the target segment was analyzed via computer-assisted planimetry. Results: Neointimal area was decreased by 71.4% at 20 Gy and by 58.3% at 15 Gy compared with control animals (p < 0.05 for both). A stimulatory effect on smooth muscle cell proliferation was noted at 10 Gy, with a 123% increase in neointimal area compared with controls (p < 0.05). Mean percent area stenosis was also reduced by 63% at 20 Gy and by 74.8% at 15 Gy compared with controls (p < 0.05 for both). Conclusions: Intracoronary irradiation prior to overstretch balloon angioplasty markedly reduces neointima formation; this effect is dose dependent, with evidence of a significant stimulatory effect at 10 Gy. The effective therapeutic dose range for the prevention of restenosis in this model begins at approximately 15 Gy delivered to the vessel wall

  2. [The Predictive Factors of Stent Failure in the Treatment of Malignant Extrinsc Ureteral Obstruction Using Internal Ureteral Stents].

    Science.gov (United States)

    Matsuura, Hiroshi; Arase, Shigeki; Hori, Yasuhide; Tochigi, Hiromi

    2017-12-01

    In this study, we retrospectively reviewed the experiences at our single institute in the treatment of malignant extrinsic ureteral obstruction (MUO) using ureteral stents to investigate the clinical outcomes and the predictive factors of stent failure. In 52 ureters of 38 patients who had radiologically significant hydronephrosis due to MUO, internal ureteral stents (The BARD(R) INLAY(TM) ureteral stent set) were inserted. The median follow-up interval after the initial stent insertion was 124.5 days (4-1,120). Stent failure occurred in 8 ureters (15.4%) of the 7 patients. The median interval from the first stent insertion to stent failure was 88 days (1-468). A Cox regression multivariate analysis showed that the significant predictors of stent failure were bladder invasion. Based on the possibility of stent failure, the adaptation of the internal ureteral stent placement should be considered especially in a patient with MUO combined with bladder invasion.

  3. Long-term Outcomes of Paclitaxel-Eluting Versus Sirolimus-Eluting Stent for Percutaneous Coronary Intervention: A Meta-Analysis

    International Nuclear Information System (INIS)

    Kong, J.; Liu, P.; Fan, X.; Wen, J.; Zhang, J.; Zhen, Y.; Li, J.; Cui, Y.; Zheng, X.; Ye, Z.

    2017-01-01

    The relative long-term efficacy and safety of sirolimus-eluting stents (SES) compared with paclitaxel-eluting stents (PES) in multiple comparative studies remains controversial. This report evaluates 29 randomized trials with 18,379 patients in whom long-term (more than 1 year) outcomes were evaluated. The primary outcomes were target lesion revascularization (TLR) and the secondary end points were death, cardiac death, myocardial infarction (MI), major adverse cardiac events (MACEs), target vessel revascularization (TVR)and stent thrombosis (ST). In comparison with PES, SES significantly reduced the long-term risk of TLR (RR=0.68; 95% CI=0.57 to 0.80, p<0.001), TVR (RR=0.69; 95% CI= 0.60 to 0.79, p<0.001) and MACE (RR=0.82; 95% CI= 0.77 to 0.88, p<0.001), while there were no significant difference with respect to death, cardiac death, MI and ST between the two groups. SES performance was significantly better for reducing the former three outcomes and comparable for the majority of the secondary end points when compared against PES. (author)

  4. Air cholangiography in endoscopic bilateral stent-in-stent placement of metallic stents for malignant hilar biliary obstruction.

    Science.gov (United States)

    Lee, Jae Min; Lee, Sang Hyub; Jang, Dong Kee; Chung, Kwang Hyun; Park, Jin Myung; Paik, Woo Hyun; Lee, Jun Kyu; Ryu, Ji Kon; Kim, Yong-Tae

    2016-03-01

    Although endoscopic bilateral stent-in-stent (SIS) placement of self-expandable metallic stents (SEMS) is one of the major palliative treatments for unresectable malignant hilar biliary obstruction, post-endoscopic retrograde cholangiopancreatography (ERCP) cholangitis can occur frequently due to inadequate drainage, especially after contrast injection into the biliary tree. The aim of this study is to evaluate the efficacy and safety of air cholangiography-assisted stenting. This study included 47 patients with malignant hilar biliary obstruction who underwent endoscopic bilateral SEMS placement using the SIS technique. They were divided into two groups, air (n = 23) or iodine contrast (n = 24) cholangiography. We retrospectively compared comprehensive clinical and laboratory data of both groups. There were no significant differences found between the two groups with respect to technical success (87% versus 87.5%, air versus contrast group, respectively), functional success (95% versus 95.2%), 30-day mortality (8.3% versus 8.7%) and stent patency. Post-ERCP adverse events occurred in 5 (21.7%) of the patients in the air group and 8 (33.3%) of the patients in the contrast group. Among these, the rate of cholangitis was significantly lower in the air group (4.8% versus 29.2%, p = 0.048). In multivariate analysis, air cholangiography, technical success and a shorter procedure time were significantly associated with a lower incidence of post-ERCP cholangitis. Air cholangiography-assisted stenting can be a safe and effective method for endoscopic bilateral SIS placement of SEMS in patients with malignant hilar biliary obstruction.

  5. Allium Stents: A Novel Solution for the Management of Upper and Lower Urinary Tract Strictures

    Directory of Open Access Journals (Sweden)

    Zaher Bahouth

    2017-10-01

    distal or very proximal strictures. We have previously published data on 107 URSs inserted in patients with ureteral stricture due to several etiologies, including patients who failed previous treatment. All patients were asymptomatic for a long period of follow-up after stent removal, with only one case of re-stenosis. In this paper, we review the urological “covered” stents produced by Allium Medical with the relevant clinical data available at the present time.

  6. In vivo distribution of c-myc antisense oligodeoxynucleotides local delivered by gelatin-coated platinmn-iridium stents in rabbits and its effect on apoptosis

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 许香广; 胡雪松; 方卫华; 邝碧娟

    2004-01-01

    Background Post-stenting restenosis is a significant clinical problem, involving vascular smooth muscle cells(VSMCs) proliferation and apoptosis. It is reported that c-myc antisense oligodeoxynucleotides (ASODNs) local delivered by catheter can inhibit VSMCs proliferation. This study was designed to assess tissue distribution of c-myc ASODN local delivered using gelatin-coated platinum-iridium (Pt-Ir) stents, and its effect on apoptosis of VSMCs. Methods Gelatin-coated Pt-Ir stents that had absorbed caroboxyfluorescein-5-succimidyl ester (FAM) labeled c-myc ASODNs (550 μg per stent) were implanted into the right carotid arteries of 6 rabbits. Tissue samples were obtained at 45 minutes, 2 hours, and 6 hours. Tissue distribution of c- myc ASODNs was assessed by fluorescence microscopy. In addition, 32 rabbits were randomly divided into two groups. Rabbits in the control group (n=16) were implanted with gelatin-coated Pt-Ir stents, and those in the treatment group (n=16) were implanted with gelatin-coated stents that had absorbed c-myc ASODNs. 7, 14, 30, or 90 days (n=4, respectively, for each group) after the stenting procedure, the stented segments were harvested, and histopathological examinations were performed to calculate neointimal area and mean neointimal thickness. The expression of c-myc was assessed using in situ hybridization (ISH) and immunohistochemical methods. Apoptotic VSMCs were detected using terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL) and transmission electron microscope (TEM). Results According to fluorescence microscopic results, FAM-labeled c-myc ASODNs were concentrated in the target vessel media at the 45 minutes time point, and then dispersed to the adventitia. Morphometric analysis showed that neointimal area and mean neointimal thickness increased continuously up to 90 days after stent implantation, but that total neointimal area and mean neointimal thickness were less in the treatment group than in the

  7. A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Directory of Open Access Journals (Sweden)

    Wehrenberg Scott

    2010-01-01

    Full Text Available Abstract Background Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials. Methods/Design The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1, single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express2 paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to Discussion The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at http://www.clinicaltrials.gov, identification numbers NCT00484315 and NCT00489541.

  8. Therapeutic effect of enterprise stent-assisted embolization for very small ruptured intracranial aneurysms.

    Science.gov (United States)

    Qin, Feiyun; Li, Zhenbao; Fang, Xinggen; Zhao, Xintong; Liu, Jiaqiang; Wu, Degang; Lai, Niansheng

    2017-08-01

    Enterprise stent has been widespread used in wide-necked intracranial aneurysms and good efficacy has been achieved, but there are few reports on its applications in very small ruptured intracranial aneurysms in literatures. This study aimed to evaluate the safety and efficacy of Enterprise stent-assisted coiling embolization of very small ruptured intracranial aneurysms.We retrospectively reviewed the clinical and imaging data from 37 patients with very small ruptured intracranial aneurysms who had SAC using Enterprise stents performed from February 2012 to July 2016 in our department. Data collected and analyzed included patient demographics, morphologic features of the aneurysm, treatment results, and follow-up results. Clinical outcomes were evaluated by the Glasgow Outcome Scale (GOS).Enterprise stents were successfully implanted in all 37 patients with very small ruptured intracranial aneurysms. Of the 37 individuals, 28 patients exhibited complete occlusion at Raymond grade I, 5 patients exhibited occlusion at Raymond grade II, and 4 patients at Raymond grade III. Procedure-related complications occurred in 3 of 37 patients (8.1%), including 1 case of intraprocedure aneurysm rupture who died from cerebral herniation caused by severe postoperative cerebral ischemia during the hospital stay, and the other 2 complications were acute in-stent thrombosis, and occlusion of parent artery caused by falling-off internal carotid artery plaque, respectively. A total of 36 patients underwent postoperative clinical follow-up visits for 6 to 24 months of which 31 patients recovered (GOS ≥ 4). One patient had hemiplegic paralysis, and no rehemorrhage was found. A total of 25 patients underwent follow-up digital subtraction angiography (DSA) at 3-21 months postintervention, in whom there were 22 cases with complete occlusion, 2 cases with recurrence of aneurysm neck, and 1 case with in-stent restenosis, but there was no patient with neurologic deficits.The Enterprise

  9. Clinical and angiographic outcomes after intracoronary bare-metal stenting.

    Directory of Open Access Journals (Sweden)

    I-Chang Hsieh

    Full Text Available BACKGROUND: Data from a large patient population regarding very long-term outcomes after BMS implantation are inadequate. This study aimed to evaluate the very long-term (8-17 years clinical and long-term (3-5 years angiographic outcomes after intracoronary bare-metal stenting (BMS. METHODS AND RESULTS: From the Cardiovascular Atherosclerosis and Percutaneous TrAnsluminal INterventions (CAPTAIN registry, a total of 2391 patients with 2966 lesions treated with 3190 BMSs between November 1995 and May 2004 were evaluated. In total, 1898 patients with 2364 lesions, and 699 patients with 861 lesions underwent 6-month and 3- to 5- year angiographic follow-up, respectively. During a mean follow-up period of 149 ± 51 months, 18.6% of the patients died (including 10.8% due to cardiac death, 6.1% developed reinfarction, 16.2% had target lesion revascularization (including 81% of the patients within the first year, 14.5% underwent new lesion stenting (including 72% of the patients after 3 years, 2.4% underwent coronary bypass surgery, and 1.6% had definite stent thrombosis. The overall cardiovascular event-free survival rate was 58.5%. The 6-month angiographic study indicated a 20% restenosis rate. The minimal luminal diameter increased from 0.65 ± 0.44 mm to 3.02 ± 0.46 mm immediately after stenting, decreased to 2.06 ± 0.77 mm at the 6-month follow-up, and increased to 2.27 ± 0.68 mm at the 3- to 5-year follow-up. CONCLUSIONS: This study provides clinical and angiographic results from a large population of patients who underwent BMS implantations after a long-term follow-up period (149 ± 51 months. The progression of coronary atherosclerosis developed over time, and presented with new lesion required stent implantation. The follow-up angiographic findings reconfirmed the late and sustained improvement in luminal diameter between 6 months and 3-5 years.

  10. Statistical Power in Meta-Analysis

    Science.gov (United States)

    Liu, Jin

    2015-01-01

    Statistical power is important in a meta-analysis study, although few studies have examined the performance of simulated power in meta-analysis. The purpose of this study is to inform researchers about statistical power estimation on two sample mean difference test under different situations: (1) the discrepancy between the analytical power and…

  11. One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry

    International Nuclear Information System (INIS)

    Sapoval, M.; Tamari, I.; Goffette, P.; Downes, M.; Senechal, Q.; Fanelli, F.; Reimer, P.; Negaiwi, Z.; Cassin, P. De; Heye, S.; Korobov, V.; Tsetis, D.; Abada, H.

    2010-01-01

    The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 ± 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 ± 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 μmol/l at baseline to 205 and 209 μmol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.

  12. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  13. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    Science.gov (United States)

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably

  14. Treatment of biliary stricture by percutaneous transhepatic insertion of metallic stent

    International Nuclear Information System (INIS)

    He Xiaofeng; Shan Hong; Chen Yong; Li Yanhao

    1997-01-01

    Purpose: Percutaneous transhepatic insertion of biliary stent (PTIBS) was adopted for treating malignant and benign biliary stricture. The therapeutic effect, technique and complications were investigated. Materials and methods: Twenty-five patients with biliary stricture were treated by PTIBS, including hilar biliary cancer 16 cases, pancreatic cancer 4 cases, hilar metastatic cancer 3 cases, and post-operative biliary stricture of bile duct 2 cases. Results: The technical success rate was 96.0% (24/25). Two stents were placed in the right and left hepatic ducts respectively in 2 cases. The survival rate of 6 and 12 months were 73.3% and 46.6%. Restenosis rate was 40.0% in 6 months. Mild hemobilia (44.0%) and retrograde infection (8.0%) were the main complications which could be managed by conservative treatment. Conclusion: It was suggested that PTIBS was a safe and effective method in the treatment of biliary stricture. There was higher success rate of PTIBS as compared to endoscopic retrograde biliary, approach especially in patients with hilar biliary stricture. If combined with chemotherapy, the survival rate of malignant biliary stricture could be further improved

  15. Meta-Analyst: software for meta-analysis of binary, continuous and diagnostic data

    Directory of Open Access Journals (Sweden)

    Schmid Christopher H

    2009-12-01

    Full Text Available Abstract Background Meta-analysis is increasingly used as a key source of evidence synthesis to inform clinical practice. The theory and statistical foundations of meta-analysis continually evolve, providing solutions to many new and challenging problems. In practice, most meta-analyses are performed in general statistical packages or dedicated meta-analysis programs. Results Herein, we introduce Meta-Analyst, a novel, powerful, intuitive, and free meta-analysis program for the meta-analysis of a variety of problems. Meta-Analyst is implemented in C# atop of the Microsoft .NET framework, and features a graphical user interface. The software performs several meta-analysis and meta-regression models for binary and continuous outcomes, as well as analyses for diagnostic and prognostic test studies in the frequentist and Bayesian frameworks. Moreover, Meta-Analyst includes a flexible tool to edit and customize generated meta-analysis graphs (e.g., forest plots and provides output in many formats (images, Adobe PDF, Microsoft Word-ready RTF. The software architecture employed allows for rapid changes to be made to either the Graphical User Interface (GUI or to the analytic modules. We verified the numerical precision of Meta-Analyst by comparing its output with that from standard meta-analysis routines in Stata over a large database of 11,803 meta-analyses of binary outcome data, and 6,881 meta-analyses of continuous outcome data from the Cochrane Library of Systematic Reviews. Results from analyses of diagnostic and prognostic test studies have been verified in a limited number of meta-analyses versus MetaDisc and MetaTest. Bayesian statistical analyses use the OpenBUGS calculation engine (and are thus as accurate as the standalone OpenBUGS software. Conclusion We have developed and validated a new program for conducting meta-analyses that combines the advantages of existing software for this task.

  16. Metallic ureteral stents in malignant ureteral obstruction: short-term results and radiological features predicting stent failure in patients with non-urological malignancies.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Wang, Shuo-Meng; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liu, Kao-Lang

    2014-06-01

    To provide short-term result of the metallic ureteral stent in patients with malignant ureteral obstruction and identify radiological findings predicting stent failure. The records of all patients with non-urological malignant diseases who have received metallic ureteral stents from July 2009 to March 2012 for ureteral obstruction were reviewed. Stent failure was detected by clinical symptoms and imaging studies. Survival analysis was used to estimate patency rates and factors predicting stent failure. A total of 74 patients with 130 attempts of stent insertion were included. A total of 113 (86.9 %) stents were inserted successfully and 103 (91.2 %) achieved primary patency. After excluding cases without sufficient imaging data, 94 stents were included in the survival analysis. The median functional duration of the 94 stents was 6.2 months (range 3-476 days). Obstruction in abdominal ureter (p = 0.0279) and lymphatic metastasis around ureter (p = 0.0398) were risk factors for stent failure. The median functional durations of the stents for abdominal and pelvic obstructions were 4.5 months (range 3-263 days) and 6.5 months (range 4-476 days), respectively. The median durations of the stents with and without lymphatic metastasis were 5.3 months (range 4-398 days) and 7.8 months (range 31-476 days), respectively. Metallic ureteral stents are effective and safe in relieving ureteral obstructions resulting from non-urological malignancies, and abdominal ureteral obstruction and lymphatic metastasis around ureter were associated with shorter functional duration.

  17. Characterization and mechanical investigation of Ti–O2−x film prepared by plasma immersion ion implantation and deposition for cardiovascular stents surface modification

    International Nuclear Information System (INIS)

    Xie Dong; Wan Guojiang; Maitz, Manfred F.; Lei Yifeng; Huang Nan; Sun Hong

    2012-01-01

    Highlights: ► We prepared Ti–O 2−x films of good quality by PIII and D successfully on stents product. ► The Ti–O 2−x film shows good homogeneity and intergradient film/substrate interface. ► The Ti–O 2−x films on stent sustain clinically-required expansion without failure. ► The films show good mechanical durability for cardiovascular stents application. - Abstract: Up to date, materials for cardiovascular stents are still far from satisfactory because of high risk of biomaterials-associated restenosis and thrombosis. Extensive efforts have been made to improve the biocompatibility of the materials by various surface modification techniques. Ti–O 2−x films prepared by plasma immersion ion implantation and deposition (PIII and D) have shown good blood compatibility. For clinical application, surface quality and mechanical durability of the Ti–O 2−x film on stents are also of critical importance for the long-term serving. In this paper we present our research results on surface quality, mechanical investigation and characterization of Ti–O 2−x films prepared using PIII and D on stent products provided by Boston Scientific SCIMED. Ti–O 2−x films with mostly Rutile and little non-stoichiometric phases were obtained with smoothness of 2−x films on stents products were sustained balloon-expansion of clinically-required extent without mechanical failure, showing highly potential feasibility for cardiovascular stents application.

  18. Evaluation of batroxobin in preventing vascular restenosis in diabetic patients after infrapopliteal arterial angioplasty: a randomized comparative study

    International Nuclear Information System (INIS)

    Xue Bo; Zhang Peilei; Wang Jue; Li Minghua; Zhao Jungong; Zhu Yueqi; Tan Huaqiao; Wang Jianbo

    2011-01-01

    Objective: To evaluate batroxobin in preventing vascular restenosis in diabetic patients after infrapopliteal arterial angioplasty through comparing the clinical results of the combination use of batroxobin and aspirin with that of simple use of aspirin. Methods: After a successful angioplasty, fifty-two diabetic patients with symptomatic infrapopliteal obstructions were randomly divided into the study group (n=26) and the control group (n=26). Patients in both groups received 100 aspirin everyday, but the patients in study group additionally received 5 IU batroxobin intravenous drip every day for six times. At the end of the follow-up period lasting for 12 months, magnetic resonance angiography (MRA) or Doppler ultrasonic angiography was performed to check the vessels to see if there was any restenosis or reocclusion. The relief degree of clinical symptoms were observed, and both preoperative and postoperative ankle-brachial index (ABI) were regularly determined and compared. Kaplan-Meier curves were constructed to evaluate restenosis/reocclusion-free rate, limb salvage rate and amputation-free rate. Results: During the follow-up period the occurrence of restenosis/reocclusion in study group and control group was 22.0% and 34.5% respectively (P=0.0307). Statistically significant difference in ABI existed between two groups both after the procedure (P<0.05) and at 12 months after the treatment (P=0.0094). Clinical improvement and tissue healing in study group and control group were observed in 23 and 19 patients respectively (P=0.0544). Twelve months after angioplasty, Kaplan-Meier analysis showed that the restenosis/reocclusion-free rate, the limb salvage rate and the amputation-free rate for study group were 74.0%, 96.2% and 84.6% respectively, while they was 54.8%, 92.3% and 84.6% respectively for control group. Conclusion: The results of this study indicate that the use of the clinical therapeutic efficacy and markedly relieve the symptoms, although this

  19. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. THE ROLE OF LIPOTROPIC THERAPY IN PATIENTS WITH CHRONIC ISCHEMIC HEART DISEASE BEFORE AND AFTER CORONARY REVASCULARIZATION

    Directory of Open Access Journals (Sweden)

    R. N. Adzhiev

    2013-01-01

    Full Text Available Review of large of trials that prove the positive impact of high-dose lipid-lowering therapy on the prognosis in patients with ischemic heart disease (IHD are presented. The data on the efficacy of the lipid profile correction by lipid apheresis in patients with hypercholesterolemia that is refractory to optimal medical therapy are showed. The results of the large trials (LIPS, ARMYDA, NAPLES II, ARMYDA-RECAPTURE, Post-CABG, TNT and meta-analyzes on the role of statins, prescribed before and after coronary artery bypass surgery and stenting, in reducing the risk of early and late cardiac events and the need for repeat myocardial revascularization are analyzed. The issue of therapeutic apheresis should be considered in cases of refractory hypercholesterolemia according to ESC/EAS Guidelines for the management of dyslipidaemias (2011. The tendency to reduction in the risk of stent restenosis and vein graft lesions after lipid apheresis is found in very high risk patients with IHD and refractory hypercholesterolemia that underwent coronary stenting or bypass surgery.