WorldWideScience

Sample records for in-reactor rupture testing

  1. In-reactor creep rupture of 20% cold-worked AISI 316 stainless steel

    International Nuclear Information System (INIS)

    Lovell, A.J.; Chin, B.A.; Gilbert, E.R.

    1981-01-01

    Results of an experiment designed to measure in-reactor stress-to-rupture properties of 20% cold-worked AISI 316 stainless steel are reported. The in-reactor rupture data are compared with postirradiation and unirradiated test results. In-reactor rupture lives were found to exceed rupture predictions of postirradiation tests. This longer in-reactor rupture life is attributed to dynamic point defect generation which is absent during postirradiation testing. The in-reactor stress-to-rupture properties are shown to be equal to or greater than the unirradiated material stress-to-rupture properties for times up to 7000 h. (author)

  2. In-reactor creep rupture behavior of the D9 alloys

    International Nuclear Information System (INIS)

    Puigh, R.J.; Hamilton, M.L.

    1986-06-01

    The uncertainties in the in-reactor stress rupture data have been significantly reduced with the acquisition of the Materials Open Test Assembly (MOTA) for testing of materials in the Fast Flux Test Facility (FFTF). The temperature uncertainty associated with irradiation in this vehicle is +- 5 0 C. Moreover, through the use of tag gases and an on-line cover gas monitoring system, on-line detection of specimen ruptures is possible during irradiation, thereby significantly reducing the uncertainty associated with the rupture times. Titanium additions, increases in nickel content and decreases in chromium content, which were made to improve the swelling response of 316 SS, resulted in an alloy class referred to as ''D9''. In-reactor stress rupture data from the MOTA experiment have been reported on two conditions of the D9-type alloys for exposure times corresponding to 2,400 hours at irradiation temperatures of 575, 605, 670, and 750 0 C. For these conditions the in-reactor rupture times were similar to those observed in thermal control tests. This report will describe both the in-reactor stress rupture behavior and the thermal control data for 20% cold work (CW) 316 SS and for 10 and 20% CW D9-type alloy over a similar temperature range for in-reactor exposure times corresponding to 13170 hr. and peak fast fluences corresponding to 17 x 10 22 n/cm 2 (E > 0.1 MeV)

  3. Rupture detection device for pipeline in reactor

    International Nuclear Information System (INIS)

    Murakoshi, Toshinori; Kanamori, Shigeru; Shirasawa, Hirofumi.

    1991-01-01

    A difference between each of the pressures in a plurality of pipelines disposed in a shroud a reactor container and a pressure outside of the shroud is detected, thereby enabling safety and reliable detection even for simultaneous rapture and leakage of the pipelines. That is, a difference between the pressure of a steam phase outside of the shroud and a pressure in each of a plurality of low pressure injection pipelines in an emergency core cooling system opened to the inside of the shroud in the reactor container is detected by a difference pressure detector for each of them. Then, an average value for each of the pressure difference is determined, which is compared with the difference pressure obtained from each of the detectors in a comparator. Then, if openings should be caused by rupture, leakage or the like in any of the pipelines, the pressure in that pipeline is lowered to a vicinity of an atmospheric pressure and at the vapor phase pressure at the lowest. If the pressure is compared with the average value by the comparator, a negative difference is caused. Accordingly, an alarming unit generates an alarm based on the pressure difference signal, thereby enabling to specify the failed pipeline and provide an announce of the failure. (I.S.)

  4. LWR primary coolant pipe rupture test rig

    International Nuclear Information System (INIS)

    Yoshitoshi, Shyoji

    1978-01-01

    The rupture test rig for primary coolant pipes is constructed in the Japan Atomic Energy Research Institute to verify the reliability of the primary coolant pipes for both PWRs and BWRs. The planned test items consisted of reaction force test, restraint test, whip test, jet test and continuous release test. A pressure vessel of about 4 m 3 volume, a circulating pump, a pressurizer, a heater, an air cooler and the related instrumentation and control system are included in this test rig. The coolant test condition is 160 kg/cm 2 g, 325 deg C for PWR test, and 70 kg/cm 2 g, saturated water and steam for BWR test, 100 ton of test load for the ruptured pipe bore of 8B Schedule 160, and 20 lit/min. discharge during 20 h for continuous release of coolant. The maximum pit internal pressure was estimated for various pipe diameters and time under the PWR and BWR conditions. The spark rupturing device was adopted for the rupture mechanics in this test rig. The computer PANAFACOM U-300 is used for the data processing. This test rig is expected to operate in 1978 effectively for the improvement of reliability of LWR primary coolant pipes. (Nakai, Y.)

  5. Liquid salt environment stress-rupture testing

    Science.gov (United States)

    Ren, Weiju; Holcomb, David E.; Muralidharan, Govindarajan; Wilson, Dane F.

    2016-03-22

    Disclosed herein are systems, devices and methods for stress-rupture testing selected materials within a high-temperature liquid salt environment. Exemplary testing systems include a load train for holding a test specimen within a heated inert gas vessel. A thermal break included in the load train can thermally insulate a load cell positioned along the load train within the inert gas vessel. The test specimen can include a cylindrical gage portion having an internal void filled with a molten salt during stress-rupture testing. The gage portion can have an inner surface area to volume ratio of greater than 20 to maximize the corrosive effect of the molten salt on the specimen material during testing. Also disclosed are methods of making a salt ingot for placement within the test specimen.

  6. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  7. Rupture disc opening property for using pipe rupture test in JAERI

    International Nuclear Information System (INIS)

    Kato, Rokuro

    1983-03-01

    In the Mechanical Strength and Structure Lab of JAERI there are being performed pipe break tests which are a postulated instantaneous guillotine break of the primary coolant piping in nuclear power plants. The test being performed are pipe whip tests and jet discharging tests. The bursting of the rupture disc is initiated by an electrical arc and is concluded by the internal pressure. Because the time characteristics during the opening of the rupture disc affects the dynamic thrust force of the pipe, it is necessary to measure these time characteristics. However, it is difficult to measure the conditions during this continuous opening because at the same time of the opening the high temperature and high pressure water is flashing. Therefore, the rupture disc opening was postulated on the measuring of the effective opening characteristics with electric contraction terminals which were attached to the inner surface of the test pipe downstream of the rupture disc and were extended toward the pipe centerline in a ring whose area is about 60 % of the area of the pipe flow sectional area. The measurement voltage was recorded when the data recorder was started in sequence with the electrical arc release from a trigger signal. As a result, it is evident that under high temperature and high pressure water the effective opening time is delayed by a few milliseconds. (author)

  8. Rupture

    CERN Multimedia

    Association du personnel

    2006-01-01

    Our Director-General is indifferent to the tradition of concertation foreseen in our statutes and is "culturally" unable to associate the Staff Association with problem-solving in staff matters. He drags his heels as long as possible before entering into negotiations, presents "often misleading" solutions at the last minute which he only accepts to change once a power struggle has been established. Faced with this rupture and despite its commitment to concertation between gentlemen. The results of the poll in which the staff is invited to participate this week. We therefore need your support to state our claims to the Governing Bodies. The Staff Association proposes a new medium of communication and thus hopes to show that it is ready for future negotiations. The pages devoted to the Staff Association are presented in a more informative, reactive and factual manner and in line with the evolution of the social situation at CERN. We want to establish strong and continuous ties between the members of CERN and ou...

  9. Observations of in-reactor endurance and rupture life for fueled and unfueled FTR cladding

    International Nuclear Information System (INIS)

    Lovell, A.J.; Christensen, B.Y.; Chin, B.A.

    1979-01-01

    Reactor component endurance limits are important to nuclear experimenters and operators. This paper investigates endurance limits of 316 CW fuel pin cladding. The objective of this paper is to compare and analyze two different sets of FTR fuel pin cladding data. The first data set is from unfueled pressurized cladding irradiated in the Experimental Breeder Reactor No. II (EBR-II). This data set was generated in an assembly in which the temperature was monitored and controlled. The second data set contains observations of breached and unbreached EBR-II test fuel pins covering a large range of temperature, power and burnup conditions

  10. Creep rupture of mild steel compact tension test pieces

    International Nuclear Information System (INIS)

    Priddle, E.K.

    1978-10-01

    Creep rupture lives have been determined for compact tension and unnotched tensile test pieces of mild steel at 450 0 C. Three sizes of compact tension specimens were used in which the ratios of reference stress to elastic stress intensity factor were 2.76, 4.78 and 6.6 (msup(-1/2)). The analysis of results in terms of either initial reference stress or stress intensity was unable to reduce the data to a single failure curve. An empirical correlation was found between rupture time and a reference stress/crack length combination where t = 2.46 x 10 20 sub(σref) sup(-8.96) asup(-1.56) (units hours, MPa and metres). This equation has no valid application to materials or specimens other than those from which it was derived. Reported data for 1/2Cr Mo V and 2 1/4Cr Mo steels at 565 0 C were also correlated by this approach. (author)

  11. Rupture tests with reactor pressure vessel head models

    International Nuclear Information System (INIS)

    Talja, H.; Keinaenen, H.; Hosio, E.; Pankakoski, P.H.; Rahka, K.

    2003-01-01

    In the LISSAC project (LImit Strains in Severe ACcidents), partly funded by the EC Nuclear Fission and Safety Programme within the 5th Framework programme, an extensive experimental and computational research programme is conducted to study the stress state and size dependence of ultimate failure strains. The results are aimed especially to make the assessment of severe accident cases more realistic. For the experiments in the LISSAC project a block of material of the German Biblis C reactor pressure vessel was available. As part of the project, eight reactor pressure vessel head models from this material (22 NiMoCr 3 7) were tested up to rupture at VTT. The specimens were provided by Forschungszentrum Karlsruhe (FzK). These tests were performed under quasistatic pressure load at room temperature. Two specimens sizes were tested and in half of the tests the specimens contain holes describing the control rod penetrations of an actual reactor pressure vessel head. These specimens were equipped with an aluminium liner. All six tests with the smaller specimen size were conducted successfully. In the test with the large specimen with holes, the behaviour of the aluminium liner material proved to differ from those of the smaller ones. As a consequence the experiment ended at the failure of the liner. The specimen without holes yielded results that were in very good agreement with those from the small specimens. (author)

  12. Status of prototype rupture disc testing in the large leak test rig

    International Nuclear Information System (INIS)

    Amos, J.C.

    1979-09-01

    The prototype CRBRP double membrane rupture disc assembly is being performance tested in conjunction with the LLTR Series II Large Leak Program. In May 1979, the double membrane disc assembly was inadvertently activated during sodium system pressure instrument calibration. This experience indicated that the rupture disc burst at essentially the design burst pressure when a gradually increasing state pressure was applied. The area of membrane opening was found to be about 25 to 30% of the cross-sectional area. In July 1979, the disc assembly was again tested (this time in a single membrane configuration) in conjunction with the first LLTR Series II Test A-1a (inert gas injection). Test data indicated that the disc burst in about 35 ms at essentially the design burst pressure with an opening of about 30% of the cross-sectional area. The pressure immediately downstream of the disc dropped below atmospheric pressure following the rupture tube event (releasing high pressure nitrogen into sodium) for about 1.5 seconds before increasing to a maximum of 30 psig. This behavior raises a question on the adequacy of a downstream pressure device for rapid sensing of disc rupture and initiating plant shutdown following a large SWR event. 14 figures

  13. Ruptured eardrum

    Science.gov (United States)

    ... eardrum ruptures. After the rupture, you may have: Drainage from the ear (drainage may be clear, pus, or bloody) Ear noise/ ... doctor to see the eardrum. Audiology testing can measure how much hearing has been lost. Treatment You ...

  14. Shakedown Tests for Refurbished and Upgraded Frames and Initiation of Alloy 709 Creep Rupture Tests

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Moser, Jeremy L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hawkins, Charles S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lara-Curzio, Edgar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    This report describes the shakedown tests conducted on the upgraded frames, and initiation of creep rupture tests on refurbished frames. SS316H, a reference material for Alloy 709, was used in shakedown tests, and the tests were conducted at 816 degree C under three stress levels to accumulate 1% creep strain. 1/4” gage diameter specimen design was used. The creep rupture tests on Alloy 709 were initiated at 600 degree C under 330 MPa to target 1,500 h rupture time. 12 specimens with 3/8” gage diameter were prepared from the materials with 6 heat treatment conditions, 2 from each. The required mechanical load under 330MPa was calculated to be 5,286 lb for the 3/8” gage diameter specimen. Among the ART frames, 7 frames are equipped with 10,000 lb load cell including #5 to 8 and #88 to 90, and can be used. 7 tests were thus started in this stage of project, and remaining 5 will be continued whenever any of the 7 tests is completed.

  15. Steam line rupture experiments with the PPOOLEX test facility

    International Nuclear Information System (INIS)

    Laine, J.; Puustinen, M.

    2008-07-01

    The results of the steam line rupture experiment series in 2007 with the scaled down PPOOLEX test facility designed and constructed at Lappeenranta University of Technology are reported. The test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. Air was blown into the dry well compartment and from there through a DN200 blowdown pipe to the condensation pool. Altogether five experiments, each consisting of several blows (tests), were carried out. The main purpose of the experiment series was to study the initial phase of a postulated steam line break accident inside a BWR containment. Specifically, thermal stratification in the dry well compartment and ejection of water plug from the blowdown pipe were of interest. In addition, the effect of counterpressure on bubble dynamics was studied. A temperature difference of approximately 15 deg. C between the upper and lower part of the dry well was measured. In the wet well gas space, a temperature difference of more than 30 deg. C was registered. These were measured during the compression period of the tests. Towards the end of the tests the temperature differences tended to disappear. To get a more detailed picture of temperature distribution in the wet well, especially close to the water level, a dense net of measurements is required in future experiments. In longer experiments, heat conduction to structures and heat losses to surroundings should also be taken into account. Ejection of water plugs from the blowdown pipe did not cause notable loads to the structures due to the suppressing effect of the dry well compartment. The maximum measured pressure pulse at the pool bottom was only 10 kPa and the maximum strain amplitude at the pool bottom rounding was negligible both in axial and circumferential direction. As the counterpressure of the system increased, but the flow rate remained the same, the maximum size of the air bubbles at the blowdown pipe outlet got smaller and

  16. Steam line rupture experiments with the PPOOLEX test facility

    Energy Technology Data Exchange (ETDEWEB)

    Laine, J.; Puustinen, M. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2008-07-15

    The results of the steam line rupture experiment series in 2007 with the scaled down PPOOLEX test facility designed and constructed at Lappeenranta University of Technology are reported. The test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. Air was blown into the dry well compartment and from there through a DN200 blowdown pipe to the condensation pool. Altogether five experiments, each consisting of several blows (tests), were carried out. The main purpose of the experiment series was to study the initial phase of a postulated steam line break accident inside a BWR containment. Specifically, thermal stratification in the dry well compartment and ejection of water plug from the blowdown pipe were of interest. In addition, the effect of counterpressure on bubble dynamics was studied. A temperature difference of approximately 15 deg. C between the upper and lower part of the dry well was measured. In the wet well gas space, a temperature difference of more than 30 deg. C was registered. These were measured during the compression period of the tests. Towards the end of the tests the temperature differences tended to disappear. To get a more detailed picture of temperature distribution in the wet well, especially close to the water level, a dense net of measurements is required in future experiments. In longer experiments, heat conduction to structures and heat losses to surroundings should also be taken into account. Ejection of water plugs from the blowdown pipe did not cause notable loads to the structures due to the suppressing effect of the dry well compartment. The maximum measured pressure pulse at the pool bottom was only 10 kPa and the maximum strain amplitude at the pool bottom rounding was negligible both in axial and circumferential direction. As the counterpressure of the system increased, but the flow rate remained the same, the maximum size of the air bubbles at the blowdown pipe outlet got smaller and

  17. Pipe rupture test results; 6 in. pipe whip test under BWR LOCA conditions

    International Nuclear Information System (INIS)

    Kurihara, Ryoichi; Yano, Toshikazu; Ueda, Shuzo; Isozaki, Toshikuni; Miyazaki, Noriyuki; Kato, Rokuro; Miyazono, Shohachiro

    1983-02-01

    A series of pipe rupture tests has been performed in JAERI to demonstrate the safety of the primary coolant circuits in the event of pipe rupture, in nuclear power plants. The present report summarizes the results of 6 in. pipe whip tests (RUN 5605, 5606), under BWR LOCA conditions (285 0 C, 6.8 MPa), which were performed in August, 1981. The test pipe is made of Type 304 stainless steel and its outer diameter is 6 in. and its thickness is 11.1 mm. The restraints are made of Type 304 stainless steel and its diameter is 16.0 mm. Two restraints were set on the restraint support with clearance of 100 mm. Overhang length was varied as the parameter in these tests and was 300 mm or 700 mm. The following results are obtained. (1) The deformations of a pipe and restraints are limited effectively by shorter overhang length of 300. However, they become larger when the overhang length is 700 mm, and the pipe deforms especially at the setting point of restraints. (2) Velocity at the free end of pipe becomes about 30 m/sec just after the break. However, velocity at the setting point of restraint becomes about only 4 m/sec just after the break. (3) It seems from the comparison between the 4 in. tests and 6 in. tests that the maximum restraint force of 6 in. tests is about two times as large as that of 4 in. tests. (author)

  18. Closed Loop In-Reactor Assembly (CLIRA): a fast flux test facility test vehicle

    International Nuclear Information System (INIS)

    Oakley, D.J.

    1978-01-01

    The Closed Loop In-Reactor Assembly (CLIRA) is a test vehicle for in-core material and fuel experiments in the Fast Flux Test Facility (FFTF). The FFTF is a fast flux nuclear test reactor operated for the Department of Energy (DOE) by Westinghouse Hanford Company in Richland, Washington. The CLIRA is a removable/replaceable part of the Closed Loop System (CLS) which is a sodium coolant system providing flow and temperature control independent of the reactor coolant system. The primary purpose of the CLIRA is to provide a test vehicle which will permit testing of nuclear fuels and materials at conditions more severe than exist in the FTR core, and to isolate these materials from the reactor core

  19. Evaluation of tube rupture simulation test (TRUST-1) for FBR steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Hayashida, Yoshihiko; Hamada, Hirotsugu [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1996-06-01

    The intermediate water leak in an FBR Steam Generator (SG) causes a high temperature and corrosive sodium-water reaction jet. In such cases, it is necessary to evaluate the wastage and overheating rupture behavior of heat transfer tubes. Especially, in the large SG that aims at high temperature of sodium and high temperature/pressure of water, the establishment of the rational evaluation method is important. In this paper, as a basic experiment to make clear the phenomenon of overheating rupture, tests and analysis of Tube Rupture Simulation Test-1 (TRUST-1) were conducted. TRUST-1 simulates the overheating rupture of the tube made of Mod.9Cr-1Mo steel by nitrogen gas pressurization and quick induction heating. The result of TRUST-1 are as follows: (1) The breaking strength predicted by the internal pressure is larger than the tensile strength of the tube material. (2) The margin of the breaking strength from the tensile strength of the tube material has a tendency of decreasing with the heating rate, especially in the lower temperature region. (3) Using an theoretical formula that is deduced from the steady creep model and appropriate experimental coefficients that are determined by the test data, the breaking strength can be reasonably evaluated. (author)

  20. Does the Lever Sign Test Have Added Value for Diagnosing Anterior Cruciate Ligament Ruptures?

    Science.gov (United States)

    Lichtenberg, Miranda C.; Koster, Christiaan H.; Teunissen, Lennart P.J.; Oosterveld, Frits G.J.; Harmsen, Annelieke M.K.; Haverkamp, Daniel; Hoornenborg, Daniel; Berg, Robert P.; Bloemers, Frank W.; Faber, Irene R.

    2018-01-01

    Background: Diagnosing an anterior cruciate ligament (ACL) rupture based on a physical examination remains a challenge for both surgeons and physical therapists. The lever sign test was developed to overcome the practical limitations of other tests and to optimize diagnosis. An evaluation of the measurement properties of the lever sign test is needed to make adequate interpretations in practice. Purpose: To evaluate the reliability and diagnostic value of the lever sign test. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: A total of 94 patients were recruited between November 2014 and July 2016. Patients were included if they were at least 16 years old, suffered from knee trauma, and had indications for knee arthroscopic surgery. Lever sign, anterior drawer, Lachman, and pivot-shift test outcomes were examined by an orthopaedic/trauma surgeon and a physical therapist. A test-retest design was used to investigate interrater reliability. Moreover, the lever sign test outcomes, alone and in combination with the other diagnostic tests, were compared with arthroscopic results, which served as the gold standard for the test’s diagnostic value. Results: The lever sign test and pivot-shift test had kappa values exceeding 0.80 for interrater reliability. The kappa values for the anterior drawer test and Lachman test were 0.80 and 0.77, respectively. The lever sign test showed the highest specificity (100%) and the lowest sensitivity (39%) when compared with the other 3 tests. Moreover, its positive and negative predictive values were 100% and 65%, respectively, while an accuracy of 71% was calculated. Clustering the lever sign test parallel with the other 3 tests resulted in the highest accuracy of 91%. Conclusion: The lever sign test appears to have high interrater reliability and is the most specific test, showing a maximal positive predictive value. A positive lever sign test result indicates an ACL rupture. These results support the added value

  1. Experiment data report for semiscale Mod-1 test S-28-2 (steam generator tube rupture test)

    International Nuclear Information System (INIS)

    Patton, M.L.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-2 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-2 was conducted from initial conditions of 15 936 kPa and 558 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. For Test S-28-2, accumulator injection into the intact loop hot leg was provided to simulate simulate the rupture of six steam generator tubes

  2. Five Tubes Rupture at Cold Side of Steam Generator Simulation Test Report Using the ATLAS

    International Nuclear Information System (INIS)

    Kang, Kyoung Ho; Park, Hyun Sik; Cho, Seok

    2010-12-01

    In this study, a postulated SGTR event of the APR1400 was experimentally investigated with the ATLAS. In order to simulate a double-ended rupture of five U-tubes in the APR1400, the SGTR-CL-02 test was performed with the ATLAS. The main objectives of this test were not only to provide a physical insight into the system response of the APR1400 during the SGTR but also to produce integral effect experimental data to validate the safety analysis code. In the present report, major thermal-hydraulic phenomena such as the system pressures, the collapsed water levels, and the break flow rate were presented and discussed. Compared to the case of a single U-tube rupture test, opening frequency of the MSSVs in the intact steam generator (SG-2) was highly reduced after 500 seconds in the present SGTR-CL-02 test. Large discharge of the primary inventory resulted in rapid depressurization of the primary system and consequently early injection of the SIP. Supply of cold ECC water by the SIPs reduced the energy transfer to the secondary side compared with the single U-tube rupture case. Less heat transfer to the secondary side had more influence on the secondary pressure of the affected steam generator than the break flow. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes of the MARS and the RELAP5 as well as the SPACE code

  3. Five Tubes Rupture at Hot Side of Steam Generator Simulation Test Report Using the ATLAS

    International Nuclear Information System (INIS)

    Kang, Kyoung Ho; Park, Hyun Sik; Cho Seok

    2010-12-01

    In this study, a postulated SGTR event of the APR1400 was experimentally investigated with the ATLAS. In order to simulate a double-ended rupture of five U-tubes in the APR1400, the SGTR-HL-05 test was performed with the ATLAS. The main objectives of this test were not only to provide a physical insight into the system response of the APR1400 during the SGTR but also to produce integral effect experimental data to validate the SPACE code. In the present report, major thermal-hydraulic phenomena such as the system pressures, the collapsed water levels, and the break flow rate were presented and discussed. On the contrary to the case of a single U-tube rupture test, the MSSV of the intact steam generator was not opened any more after 1500 seconds in the present SGTR-HL-05 test. Large discharge of the primary inventory resulted in rapid depressurization of the primary system and consequently early injection of the SIP. Supply of cold ECC water by the SIPs reduced the energy transfer to the secondary side compared with the single U-tube rupture case. Less heat transfer to the secondary side had more influence on the secondary pressure of the affected steam generator than the break flow. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes of the MARS and the RELAP5 as well as the SPACE code

  4. Experiment data report for Semiscale Mod-1 test S-28-3 (steam generator tube rupture test)

    International Nuclear Information System (INIS)

    Gillins, R.L.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-3 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-3 was conducted from initial conditions of 15621 kPa and 555 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Twelve steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  5. Experiment data report for Semiscale Mod-1 Test S-28-1 (steam generator tube rupture test series)

    International Nuclear Information System (INIS)

    Collins, B.L.; Coppin, C.E.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-1 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-1 was conducted from initial conditions of 15 767 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Sixty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  6. Experiment data report for semiscale Mod-1 test S-28-4 (steam generator tube rupture test)

    International Nuclear Information System (INIS)

    Esparza, V.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-4 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-4 was conducted from initial conditions of 15 646 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Thirty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  7. Further development of remote testing of submerged bolts and screws in reactors

    International Nuclear Information System (INIS)

    Mohr, F.; Schirner, G.; Meier, R.; Wiesinger, W.

    2007-01-01

    Since the eighties, intelligeNDT has been carrying out ultrasonic tests of bolts in reactor containments and pressure vessels both in Germany and abroad. The ultrasonic equipment used belonged to the SAPHIR/SAPHIRplus line. The recording and online evaluation software was adapted to the test requirements and optimized for high test rates and quality-assured documentation. As test manipulator, the ''SUSI'' submarine by AREVA NP was used with good results. (orig.)

  8. Facility for in-reactor creep testing of fuel cladding

    International Nuclear Information System (INIS)

    Kohn, E.; Wright, M.G.

    1976-11-01

    A biaxial stress creep test facility has been designed and developed for operation in the WR-1 reactor. This report outlines the rationale for its design and describes its construction and the operating experience with it. The equipment is optimized for the determination of creep data on CANDU fuel cladding. Typical results from Zr-2.5 wt% Nb fuel cladding are used to illustrate the accuracy and reliability obtained. (author)

  9. Viscoelastic characterization of carbon fiber-epoxy composites by creep and creep rupture tests

    International Nuclear Information System (INIS)

    Farina, Luis Claudio

    2009-01-01

    One of the main requirements for the use of fiber-reinforced polymer matrix composites in structural applications is the evaluation of their behavior during service life. The warranties of the integrity of these structural components demand a study of the time dependent behavior of these materials due to viscoelastic response of the polymeric matrix and of the countless possibilities of design configurations. In the present study, creep and creep rupture test in stress were performed in specimens of unidirectional carbon fiber-reinforced epoxy composites with fibers orientations of 60 degree and 90 degree, at temperatures of 25 and 70 degree C. The aim is the viscoelastic characterization of the material through the creep curves to some levels of constant tension during periods of 1000 h, the attainment of the creep rupture envelope by the creep rupture curves and the determination of the transition of the linear for non-linear behavior through isochronous curves. In addition, comparisons of creep compliance curves with a viscoelastic behavior prediction model based on Schapery equation were also performed. For the test, a modification was verified in the behavior of the material, regarding the resistance, stiffness and deformation, demonstrating that these properties were affected for the time and tension level, especially in work temperature above the ambient. The prediction model was capable to represent the creep behavior, however the determination of the equations terms should be considered, besides the variation of these with the applied tension and the elapsed time of test. (author)

  10. Permeated defect detecting test method and device in reactor

    International Nuclear Information System (INIS)

    Sakurai, Yoshishige.

    1996-01-01

    The present invention provides a method of and a device capable of performing a test for entire inner surfaces of the reactor upon periodical inspection of a BWR type reactor while sufficiently taking countermeasures for radiation rays into consideration. Namely, the present invention comprises following steps. (1) A provisional step for taking a shroud head of a reactor core shroud and incore structural components above and below the shroud out of the reactor, discharging reactor water and water tightly closing openings such as reactor wall perforation holes, (2) a pretreatment step for washing exposed inner surfaces of the reactor and peeling deteriorated materials, (3) a first drying step for drying portions washed and peeled in the step (2), (4) a permeation step for applying a permeation liquid of a defect detecting medium on the exposed inner surfaces of the reactor, (5) a permeation liquid removing step for removing the an excess permeation liquid in the step (4), (6) a second drying step for drying corresponding portions after performing the step (5), and (7) a flaw detecting step for optically observing the corresponding portions after performing the step (6) and detecting flaws. (I.S.)

  11. In-reactor deformation and fracture of austenitic stainless steels

    International Nuclear Information System (INIS)

    Bloom, E.E.; Wolfer, W.G.

    1978-01-01

    An experimental technique for determining in-reactor fracture strain was developed and demonstrated. Differential swelling between a sample holder and a test specimen with a lower swelling rate produced uniaxial deformation. In-reactor deformations of 0.7 to 2.1% were achieved in type 304 stainless steel previously irradiated to fluences up to 8.8 x 10 26 n/m 2 without fracture. These strains are significantly higher than found in postirradiation creep-rupture tests on similar samples. From the measured strain values and published irradiation creep data and correlations, the stress levels during the irradiation were calculated. On the basis of previous postirradiation creep-rupture results, many of the samples that did not fail would be predicted to fail. Thus we conclude that the in-reactor rupture life is longer than predicted by postirradiation tests. Strain in a fractured sample was estimated to be less than 3.8%, and the in-reactor fractures were intergranular--the same fracture mode as found in postirradiation tests. Irradiation creep may relax stresses at crack tips and sliding boundaries, thus retarding the initiation and/or growth of cracks and leading to longer rupture lives in-reactor. However, the very high ductility or superplastic behavior predicted by the strain rate sensitivity of irradiation creep is not achieved because of the eventual interruption of the deformation process by grain boundary fracture

  12. Code Assessment of SPACE 2.19 using LSTF Steam Generator Tube Rupture Test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Minhee; Kim, Seyun [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The SPACE is a best estimated two-phase three-field thermal-hydraulic analysis code used to analyze the safety and performance of pressurized water reactors. As a result of the development, the 2.19 version of the code was released through the successive various verification and validation works. The present work is on the line of expanding the work by Kim et al. In this study, results produced by the SPACE 2.19 code were compared with the experimental data from JAERI's LSTF Test Run LSTF SB-SG-06 experiment simulating a Steam Generator Tube Rupture (SGTR) transient. In order to identify the predictability of SPACE 2.19, the LSTF steam generator tube rupture test was simulated. To evaluate the computed results, LSTF SB-SG-06 test data simulating the SGTR and the RELAP5/ MOD3.1 are used. The calculation results indicate that the SPACE 2.19 code predicted well the sequence of events and the major phenomena during the transient, such as the asymmetric loop behavior, reactor coolant system cooldown and heat transfer by natural circulation, the primary and secondary system depressurization by the pressurizer auxiliary spray and the steam dump using the intact loop steam generator relief valve.

  13. Advantages of the experimental animal hollow organ mechanical testing system for the rat colon rupture pressure test.

    Science.gov (United States)

    Ji, Chengdong; Guo, Xuan; Li, Zhen; Qian, Shuwen; Zheng, Feng; Qin, Haiqing

    2013-01-01

    Many studies have been conducted on colorectal anastomotic leakage to reduce the incidence of anastomotic leakage. However, how to precisely determine if the bowel can withstand the pressure of a colorectal anastomosis experiment, which is called anastomotic bursting pressure, has not been determined. A task force developed the experimental animal hollow organ mechanical testing system to provide precise measurement of the maximum pressure that an anastomotic colon can withstand, and to compare it with the commonly used method such as the mercury and air bag pressure manometer in a rat colon rupture pressure test. Forty-five male Sprague-Dawley rats were randomly divided into the manual ball manometry (H) group, the tracing machine manometry pressure gauge head (MP) group, and the experimental animal hollow organ mechanical testing system (ME) group. The rats in each group were subjected to a cut colon rupture pressure test after injecting anesthesia in the tail vein. Colonic end-to-end anastomosis was performed, and the rats were rested for 1 week before anastomotic bursting pressure was determined by one of the three methods. No differences were observed between the normal colon rupture pressure and colonic anastomotic bursting pressure, which were determined using the three manometry methods. However, several advantages, such as reduction in errors, were identified in the ME group. Different types of manometry methods can be applied to the normal rat colon, but the colonic anastomotic bursting pressure test using the experimental animal hollow organ mechanical testing system is superior to traditional methods. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  14. In-reactor testing of self-powered neutron detectors and miniature fission chambers

    International Nuclear Information System (INIS)

    Duchene, J.; LeMeur, R.; Verdant, R.

    1975-01-01

    The CEA has tested a variety of ''slow'' self-powered neutron detectors with rhodium, silver and vanadium emitters. Currently there are 120 vanadium detectors in the EL4 heavy water reactor. In addition, ''fast'' detectors with cobalt emitters have been tested at Saclay and 50 of these are in reactor. Other studies are concerned with 6 mm diameter miniature fission chambers. Two fast response chambers with argon-nitrogen filling gas became slow during irradiation, but operated to 600 deg C. An argon filled chamber of 4.7 mm diameter, for traversing in core system in pressurized water reactor, has shown satisfactory test results. (author)

  15. Single Tube Rupture at Cold Side of Steam Generator Simulation Test Report Using the ATLAS

    International Nuclear Information System (INIS)

    Kang, Kyoung Ho; Park, Hyun Sik; Cho, Seok

    2010-12-01

    In this study, a postulated SGTR event of the APR1400 was experimentally investigated with the ATLAS. In order to simulate a double-ended rupture of a single U-tube in the APR1400, the SGTR-CL-01 test was performed with the ATLAS. The main objectives of this test were not only to provide a physical insight into the system response of the APR1400 during the SGTR but also to produce integral effect experimental data to validate the safety analysis code. In the present report, major thermal-hydraulic phenomena such as the system pressures, the collapsed water levels, and the break flow rate were presented and discussed. Following the reactor trip induced by high steam generator level (HSGL) signal, the primary system pressure decreased and the secondary system pressure increased until the MSSVs was opened. The MSSVs repeated on and off status depending on the secondary system pressure during the whole test period. Due to the break flow, the collapsed water level of the affected steam generator showed milder decrease than that of the intact steam generator. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes of the MARS and the RELAP5 as well as the SPACE code. Furthermore, this data can be utilized to identify any code deficiency for a SGTR simulation, especially for DVI-adapted plants

  16. Accuracy of physical diagnostic tests for assessing ruptures of the anterior curciate ligament: a meta-analysis.

    NARCIS (Netherlands)

    Scholten, R.J.P.M.; Opstelten, W.; Plas, C.G. van der; Bijl, D.; Devillé, W.L.J.M.; Bouter, L.M.

    2003-01-01

    OBJECTIVE: This systematic review summarizes the evidence on the accuracy of tests for assessing ACL ruptures of the knee. SEARCH STRATEGY: A computerized search of MEDLINE (1966-2003) and EMBASE (1980-2003) with additional reference tracking. SELECTION CRITERIA: Articles included were written in

  17. Methods to diagnose acute anterior cruciate ligament rupture: a meta-analysis of instrumented knee laxity tests

    NARCIS (Netherlands)

    van Eck, Carola F.; Loopik, Miette; van den Bekerom, Michel P.; Fu, Freddie H.; Kerkhoffs, Gino M. M. J.

    2013-01-01

    The aims of this meta-analysis were to determine the sensitivity and specificity of the KT 1000 Arthrometer, Stryker Knee Laxity Tester and Genucom Knee Analysis System for ACL rupture. It was hypothesized that the KT 1000 test is the most sensitive and specific. Secondly, it was hypothesized that

  18. Physical examination tests for the diagnosis of posterior cruciate ligament rupture: a systematic review.

    Science.gov (United States)

    Kopkow, Christian; Freiberg, Alice; Kirschner, Stephan; Seidler, Andreas; Schmitt, Jochen

    2013-11-01

    Systematic literature review. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of posterior cruciate ligament (PCL) tear. Rupture of the PCL is a severe knee injury that can lead to delayed rehabilitation, instability, or chronic knee pathologies. To our knowledge, there is currently no systematic review of studies on the diagnostic accuracy of clinical examination tests to evaluate the integrity of the PCL. A comprehensive systematic literature search was conducted in MEDLINE from 1946, Embase from 1974, and the Allied and Complementary Medicine Database from 1985 until April 30, 2012. Studies were considered eligible if they compared the results of physical examination tests performed in the context of a PCL physical examination to those of a reference standard (arthroscopy, arthrotomy, magnetic resonance imaging). Methodological quality assessment was performed by 2 independent reviewers using the revised version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The search strategy revealed 1307 articles, of which 11 met the inclusion criteria for this review. In these studies, 11 different physical examination tests were identified. Due to differences in study types, different patient populations, and methodological quality, meta-analysis was not indicated. Presently, most physical examination tests have not been evaluated sufficiently enough to be confident in their ability to either confirm or rule out a PCL tear. The diagnostic accuracy of physical examination tests to assess the integrity of the PCL is largely unknown. There is a strong need for further research in this area. Level of Evidence Diagnosis, level 3a.

  19. Pipe rupture test results: 4-inch pipe whip tests under PWR LOCA conditions

    International Nuclear Information System (INIS)

    Miyazaki, Noriyuki; Ueda, Shuzo; Isozaki, Toshikuni; Kato, Rokuro; Kurihara, Ryoichi; Yano, Toshikazu; Miyazono, Shohachiro

    1982-09-01

    This report summarizes the results of 4-inch pipe whip tests (RUN No. 5506, 5507, 5508 and 5604) under the PWR LOCA conditions. The dynamic behaviors of the test pipe and restraints were studied in the tests. In the tests, the gap between the test pipe and the restraints was kept at the constant value of 8.85 mm and the overhang length was varied from 250 mm to 650 mm. The dynamic behaviors of the test pipe and the restraint were made clear by the outputs of strain gages and the measurements of residual deformations. The data of water hammer in subcooled water were also obtained by the pressure transducers mounted on the test pipe. The main conclusions obtained from the tests are as follows. (1) The whipping of pipe can be prevented more effectively as the overhang length becomes shorter. (2) The load acting on the restraint-support structure becomes larger as the overhang length becomes shorter. (3) The restraint farther from the break location does not limit the pipe movement except for the first impact when the overhang length is long. (4) The ultimate moment M sub(u) of the pipe at the restraint location can be used to predict the plastic collapse of the whipping pipe. (5) The restraints slide along the pipe axis and are subjected to bending moment, when the overhang length is long. (author)

  20. Probability of a surface rupture offset beneath a nuclear test reactor

    International Nuclear Information System (INIS)

    Reed, J.W.; Meehan, R.L.; Crellin, G.L.

    1981-01-01

    A probabilistic analysis was conducted to determine the likelihood of a surface rupture offset of any size beneath the 50 megawatt General Electric Test Reactor (GETR), which is located at the Vallecitos Nuclear Center near Pleasanton, California. Geologic faults have been observed at the GETR site. These faults may be due to surface folds, landslides, or deep tectonic movement. They are referred to in the paper as 'existing faults;' however, use of this term does not imply that they are tectonic in origin. The objective of the analysis was to evaluate whether a conservative estimate of the probability of occurrence of a future fault movement is sufficiently low so that movement beneath the reactor building need not be considered as a design basis event. The reactor building is located between two existing faults which are approximately 1320 feet apart. If a fault movement occurs in the future, it is conservatively assumed to occur either on the existing faults or between the faults, or on a fault(s) and between the two faults at the same time. The probabilistic model included the possibility of movements occurring due to unknown, undiscovered faults in the region. For this part, movements were assumed to occur according to a Poisson process. For the possibility of new faults occurring due to the two existing faults, a hazard function was used which increases with time since the last offset. (orig./RW)

  1. Pipe rupture test results; 4 inch pipe whip tests under BWR operational condition-clearance parameter experiments

    International Nuclear Information System (INIS)

    Ueda, Syuzo; Isozaki, Toshikuni; Miyazaki, Noriyuki; Kurihara, Ryoichi; Kato, Rokuro; Saito, Kazuo; Miyazono, Shohachiro

    1981-05-01

    The purpose of pipe rupture studies in JAERI is to perform the model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish the computational method for analyzing these phenomena. This report describes the experimental results of pipe whip on the pipe specimens of 4 inch in diameter under BWR condition on which the pressure is 6.77 MPa and the temperature is 285 0 C. The pipe specimens were 114.3 mm (4 inch) in diameter and 8.6 mm in thickness and 4500 mm in length. Four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and fabricated from type 304 stainless steel. The experimental parameter was the clearance (30, 50 and 100 mm). The dynamic strain behavior of the pipe specimen and the restraints was investigated by strain gages and their residual deformation was obtained by measuring marking points provided on their surface. The Pressure-time history in the pipe specimens was also obtained by pressure gages. The maximum pipe strain is caused near the restraints and increases with increase of the clearance. The experimental results of pipe whip tests indicate the effectiveness of pipe whip restraints. The ratio of absorbed strain energy of the pipe specimen to that of the restraints is nearly constant for different clearances at the overhang length of 400 mm. (author)

  2. Test amnioinfusion to determine suitability for serial therapeutic amnioinfusion in midtrimester premature rupture of membranes.

    Science.gov (United States)

    Tan, L-K; Kumar, S; Jolly, M; Gleeson, C; Johnson, P; Fisk, N M

    2003-01-01

    To evaluate whether a test amnioinfusion procedure is useful in selecting cases of midtrimester preterm premature rupture of membranes (PPROM) which may benefit from serial amnioinfusions if the initial fluid is retained. The Centre for Fetal Care database between 1992 and 2000 was reviewed for women with PPROM amnioinfusion. Amniotic fluid index (AFI) was assessed before and after a test amnioinfusion procedure. Those who retained fluid > or =48 h underwent serial AFI assessment with a view to serial amnioinfusion when oligohydramnios recurred. Eighty-five amnioinfusion procedures were performed in 60 women with oligohydramnios. Nineteen of these women presented with confirmed PPROM at a median gestation of 19 (range 15-22) weeks and severe olighohydramnios (median AFI 1, range 0-3 cm), in whom 20 test amnioinfusions were carried out. Two amnioinfusions were abandoned during the procedure because of fetal bradycardia and both mothers opted for termination of pregnancy. Only 4 women retained fluid during the test amnioinfusion, 1 of whom miscarried at 19 weeks before serial amnioinfusion could be started. The remaining 3 underwent a median of 4 (range 1-6) serial amnioinfusion procedures; none had evidence of pulmonary hypoplasia. Thirteen (68%) leaked fluid within 48 h; within this group there was 1 subsequent miscarriage and 9 pregnancy terminations. The remaining 3 pregnancies resulted in livebirths 2 of which had pulmonary hypoplasia with 1 early neonatal death. Overall survival was poor (4/19), largely attributed to the high incidence of terminations in the presence of persistent severe oligohydramnios. In continuing pregnancies reaching viability survival was 67% (4 of 6). Three quarters of women with mid-trimester PPROM lose fluid at test amnioinfusion and therefore would not be suitable candidates for serial amnioinfusion. However, if infused fluid is retained, this allows subsequent serial amnioinfusion and prolongation of pregnancy in about 75%, with an

  3. The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes

    Directory of Open Access Journals (Sweden)

    Maryam Khooshideh

    2015-06-01

    Full Text Available Background: Premature rupture of membranes (PROM is a common obstetric issue during pregnancy which might lead to serious fetal or maternal problems. Therefore, an appropriate diagnosis and management of PROM are of significant importance in patients. Objective: The aim of this study was to determine the accuracy of placental alpha microglobuline-1 (PAMG-1 test in PROM diagnosis and compare this diagnostic method with other standard tests in diagnosis of PROM. Materials and Methods: In this prospective diagnostic accuracy study, patients with symptoms of membrane rupture in 16-39 weeks of gestation were involved. Three tests including Fern, Nitrazine and PAMG-1 were performed at the same time. Results: PROM was confirmed in 86 patients out of 100. The sensitivity and specificity were respectively 81.3% and 100% for Fern test, 93% and 92.8% for Nitrazine test, 98.9% and 92.8% for PAMG-1 test. PAMG-1 test showed higher sensitivity (98.9% with p<0.001 and accuracy (98% compared with conventional tests. Although PAMG-1showed a lower positive predictive value (PPV compared to conventional tests such as Fern test (100%, it was shown to be more accurate. Conclusion: The accuracy of PAMG-1 test was superior to both Fern and Nitrazine test in PROM diagnosis.

  4. Technique for the residual life assessment of high temperature components based on creep-rupture testing on welded miniature specimens

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, A.; Guardamagna, C.; Moscotti, L.; Ranzani, L. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-06-01

    Following the present trend in the development of advanced methodologies for residual life assessment of high temperature components operating in power plants, particularly in non destructive methods, a testing technique has been set up at ENEL-CRAM based on creep-rupture testa in an argon on welded miniature specimens. Five experimental systems for creep-rupture tests in an argon atmosphere have been set up which include high accuracy systems, vacuum chambers and exrwnsometer devices. With the aim of establishing and validating the suitability of the experimental methodology, creep-rupture and interrupted creep testing programmes have been performed on miniature specimens (2 mm diameter and 10 mm gauge lenght). On the basis of experience gathered by various European research laboratories, a miniature specimen construction procedure has been developed using a laser welding technique for joining threaded heads to sample material. Low alloy ferritic steels, such as virgin 2.25CrlMo, 0.5Cr 0.5Mo 0.25V, and IN 738 superalloy miniature specimens have been investigated and the results, compared with those from standard specimens, show a regular trend in deformation vs time. Additional efforts to provide guidelines for material sampling from each plant component will be required in order to reduce uncertainties in residual life prediction.

  5. Nondestructive Evaluation and Monitoring Results from COPV Accelerated Stress Rupture Testing, NASA White Sands Test Facility (WSTF)

    Science.gov (United States)

    Saulsberry Regor

    2010-01-01

    Develop and demonstrate NDE techniques for real-time characterization of CPVs and, where possible, identification of NDE capable of assessing stress rupture related strength degradation and/or making vessel life predictions (structural health monitoring or periodic inspection modes). Secondary: Provide the COPV user and materials community with quality carbon/epoxy (C/Ep) COPV stress rupture progression rate data. Aid in modeling, manufacturing, and application of COPVs for NASA spacecraft.

  6. Manufacturing and testing in reactor relevant conditions of brazed plasma facing components of the ITER divertor

    International Nuclear Information System (INIS)

    Bisio, M.; Branca, V.; Marco, M. Di; Federici, A.; Grattarola, M.; Gualco, G.; Guarnone, P.; Luconi, U.; Merola, M.; Ozzano, C.; Pasquale, G.; Poggi, P.; Rizzo, S.; Varone, F.

    2005-01-01

    A fabrication route based on brazing technology has been developed for the realization of the high heat flux components for the ITER vertical target and Dome-Liner. The divertor vertical target is armoured with carbon fiber reinforced carbon and tungsten in the lower straight part and in the upper curved part, respectively. The armour material is joined to heat sinks made of precipitation hardened copper-chromium-zirconium alloy. The plasma facing units of the dome component are based on a tungsten flat tile design with hypervapotron cooling. An innovative brazing technique based on the addition of carbon fibers to the active brazing alloy, developed by Ansaldo Ricerche for applications in the field of the energy production, has been used for the carbon fiber composite to copper joint to reduce residual stresses. The tungsten-copper joint has been realized by direct casting. A proper brazing thermal cycle has been studied to guarantee the required mechanical properties of the precipitation hardened alloy after brazing. The fabrication route of plasma facing components for the ITER vertical target and dome based on the brazing technology has been proved by means of thermal fatigue tests performed on mock-ups in reactor relevant conditions

  7. Modelling ground rupture due to groundwater withdrawal: applications to test cases in China and Mexico

    Science.gov (United States)

    Franceschini, A.; Teatini, P.; Janna, C.; Ferronato, M.; Gambolati, G.; Ye, S.; Carreón-Freyre, D.

    2015-11-01

    The stress variation induced by aquifer overdraft in sedimentary basins with shallow bedrock may cause rupture in the form of pre-existing fault activation or earth fissure generation. The process is causing major detrimental effects on a many areas in China and Mexico. Ruptures yield discontinuity in both displacement and stress field that classic continuous finite element (FE) models cannot address. Interface finite elements (IE), typically used in contact mechanics, may be of great help and are implemented herein to simulate the fault geomechanical behaviour. Two main approaches, i.e. Penalty and Lagrangian, are developed to enforce the contact condition on the element interface. The incorporation of IE incorporation into a three-dimensional (3-D) FE geomechanical simulator shows that the Lagrangian approach is numerically more robust and stable than the Penalty, thus providing more reliable solutions. Furthermore, the use of a Newton-Raphson scheme to deal with the non-linear elasto-plastic fault behaviour allows for quadratic convergence. The FE - IE model is applied to investigate the likely ground rupture in realistic 3-D geologic settings. The case studies are representative of the City of Wuxi in the Jiangsu Province (China), and of the City of Queretaro, Mexico, where significant land subsidence has been accompanied by the generation of several earth fissures jeopardizing the stability and integrity of the overland structures and infrastructure.

  8. Effect of transient liquid phase (TLP) bonding on the ductility of a Ni-base single crystal superalloy in a stress rupture test

    International Nuclear Information System (INIS)

    Liu, J.D.; Jin, T.; Zhao, N.R.; Wang, Z.H.; Sun, X.F.; Guan, H.R.; Hu, Z.Q.

    2008-01-01

    A Ni-base single crystal superalloy was transient liquid phase (TLP) bonded using a Ni-Cr-B amorphous foil at 1230 deg. C for 8 h. Stress rupture tests of the TLP joint and a matrix sample were carried out at 982 deg. C/248 MPa and 1010 deg. C/248 MPa. The microstructures and fracture surfaces were studied using scanning electron microscopy (SEM). Transmission electron microscopy (TEM) investigations were performed after creep rupture testing to examine the deformation substructures. The results show that the stress rupture ductility of TLP joints is significantly decreased compared to the matrix sample. This reduction of the ductility of TLP joints can be attributed to solid solution strengthening by boron atoms, subgrain boundaries formed in the bonding zone and the concentration of creep cavities formed during the last stage of the stress rupture test

  9. Diagnostic performance of placental alpha-microglobulin-1 test in women with prolonged pre-labour rupture of membranes.

    Science.gov (United States)

    Eleje, George Uchenna; Ezugwu, Euzebus Chinonye; Eke, Ahizechukwu Chigoziem; Eleje, Lydia Ijeoma; Ikechebelu, Joseph Ifeanyichukwu; Afiadigwe, Evaristus Anthony; Ezugwu, Frank O; Udigwe, Gerald Okanandu; Okafor, Charles I; Ezeama, Chukwuemeka Okwudili

    2016-01-01

    To determine diagnostic performance of placental alpha-microglobulin-1 (PAMG-1) test compared to conventional clinical assessment (CCA) in women with prolonged pre-labour rupture of membranes (PROM). A double-blind study of women with symptoms and signs of PROM in Nnamdi Azikiwe University Teaching Hospital, Nnewi and University of Nigeria Teaching Hospital, Enugu, in south-east Nigeria using CCA for PROM and PAMG-1 test was done. Women were included if their symptoms, signs or complaints suggestive of PROM was more than 24 h duration. PROM was diagnosed if two out of three methods from CCA (pooling, positive nitrazine test or ferning) were present. Confirmation of PROM was done after delivery using any two of these clinical criteria: delivery in 48 h to 7 days, evidence of chorioamnionitis, membranes obviously ruptured at delivery and adverse perinatal outcomes strongly correlated with prolonged PROM. Accuracy, specificity and sensitivity value for CCA were 72.5, 36.8 and 86.0% lower than for PAMG-1 test which were 95.7, 94.1 and 96.2%. In equivocal cases, PAMG-1 was significantly more accurate than CCA (92.3% versus 38.5%; p < 0.001). This study in women with prolonged PROM, confirms that PAMG-1 test has high diagnostic accuracy irrespective of the duration of PROM before clinical evaluation.

  10. Microballoon Occlusion Test to Predict Colonic Ischemia After Transcatheter Embolization of a Ruptured Aneurysm of the Middle Colic Artery

    International Nuclear Information System (INIS)

    Tajima, Tsuyoshi; Yoshimitsu, Kengo; Inokuchi, Hiroyuki; Irie, Hiroyuki; Nishie, Akihiro; Hirakawa, Masakazu; Ishigami, Kousei; Ushijima, Yasuhiro; Okamoto, Daisuke; Honda, Hiroshi; Itoh, Hiroyuki; Morita, Masaru; Kakeji, Yoshihiro

    2008-01-01

    A 76-year-old woman presented with sudden massive melena, and superior mesenteric arteriography showed an aneurysm in the middle colic artery (MCA). Because she had a history of right hemicolectomy and ligation of the inferior mesenteric artery (IMA) during open abdominal aortic aneurysm repair, embolization of the MCA aneurysm was considered to pose a risk comparable to that of colonic ischemia. A microballoon occlusion test during occlusion of the MCA confirmed retrograde visualization of the IMA branches through the collateral arteries by way of the left internal iliac artery, and embolization was successfully performed using microcoils. No colonic ischemia or aneurysm rupture occurred after embolization.

  11. Bayes Analysis and Reliability Implications of Stress-Rupture Testing a Kevlar/Epoxy COPV Using Temperature and Pressure Acceleration

    Science.gov (United States)

    Phoenix, S. Leigh; Kezirian, Michael T.; Murthy, Pappu L. N.

    2009-01-01

    Composite Overwrapped Pressure Vessels (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Flight certification is dependent on the reliability analysis to quantify the risk of stress rupture failure in existing flight vessels. Full certification of this reliability model would require a statistically significant number of lifetime tests to be performed and is impractical given the cost and limited flight hardware for certification testing purposes. One approach to confirm the reliability model is to perform a stress rupture test on a flight COPV. Currently, testing of such a Kevlar49 (Dupont)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the database and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio model is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one "nine," that is, reducing the predicted probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several vessels would be necessary.

  12. Rupture disc

    International Nuclear Information System (INIS)

    Newton, R.G.

    1977-01-01

    The intermediate heat transport system for a sodium-cooled fast breeder reactor includes a device for rapidly draining the sodium therefrom should a sodium-water reaction occur within the system. This device includes a rupturable member in a drain line in the system and means for cutting a large opening therein and for positively removing the sheared-out portion from the opening cut in the rupturable member. According to the preferred embodiment of the invention the rupturable member includes a solid head seated in the end of the drain line having a rim extending peripherally therearound, the rim being clamped against the end of the drain line by a clamp ring having an interior shearing edge, the bottom of the rupturable member being convex and extending into the drain line. Means are provided to draw the rupturable member away from the drain line against the shearing edge to clear the drain line for outflow of sodium therethrough

  13. Experimental evaluation of emergency operating procedures on multiple steam generator tube rupture in INER integral system test facility

    International Nuclear Information System (INIS)

    Liu, T.J.; Lin, Y.M.; Lee, C.H.; Chang, C.Y.; Hong, W.T.

    1997-01-01

    The multiple steam generator tube rupture (SGTR) scenario in Westinghouse type pressurized water reactor (PWR) has been investigated at the Institute of Nuclear Energy Research (INER) Integral System Test (IIST) facility. This reduced-height and reduced-pressure test facility was designed to simulate the main features of Maanshan nuclear power plant. The SGTR test scenario assumes the double-ended break of one-, two- and six- tubes without other failures. The major operator actions follow the related symptom-oriented Emergency Operating Procedure (EOP) on the reference plant. This study focuses on the investigation of thermal-hydraulics phenomena and the adequacy of associated EOP to limit primary-to-secondary leakage. Through this study, it is found that the adequacy of current EOP in minimizing the radioactivity release demands early substantial operator involvement, especially in the multi-tubes break events. Also, the detailed mechanism of the main thermal-hydraulic phenomena during the SGTR transient are explored. (author)

  14. Prediction of long time creep rupture properties of welded joints using the results of short duration creep crack incubation tests

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, E.

    2013-07-01

    This dissertation submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the applicability of the LICON methodology for the prediction of long-time creep rupture strength of a dissimilar metal weld. The LICON methodology is an approach for predicting the lifetime of materials under creep loading conditions. It predicts long-time uniaxial creep strength using the results from several short duration creep crack incubation tests in conjunction with the outcome of a mechanical analysis on the test-piece. This study has re-examined the previous application of the LICON methodology for 9%Cr and 1CrMoV steels. It has shown that application of the original Lion method (based on reference stress solutions) for certain materials is not appropriate. This study therefore proposes a new development for the Lion approach which uses finite-element analysis to account for the generated multiaxial stress states within welded uniaxial test-pieces.

  15. Prediction of long time creep rupture properties of welded joints using the results of short duration creep crack incubation tests

    International Nuclear Information System (INIS)

    Hosseini, E.

    2013-01-01

    This dissertation submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the applicability of the LICON methodology for the prediction of long-time creep rupture strength of a dissimilar metal weld. The LICON methodology is an approach for predicting the lifetime of materials under creep loading conditions. It predicts long-time uniaxial creep strength using the results from several short duration creep crack incubation tests in conjunction with the outcome of a mechanical analysis on the test-piece. This study has re-examined the previous application of the LICON methodology for 9%Cr and 1CrMoV steels. It has shown that application of the original Lion method (based on reference stress solutions) for certain materials is not appropriate. This study therefore proposes a new development for the Lion approach which uses finite-element analysis to account for the generated multiaxial stress states within welded uniaxial test-pieces

  16. In-reactor fatigue crack propagation

    International Nuclear Information System (INIS)

    Ermi, A.M.; Mervyn, D.A.; Straalsund, J.L.

    1979-08-01

    An in-reactor fatigue experiment is being designed to determine the effect of dynamic irradiation on the fatigue crack propagation (FCP) behavior of candidate fusion first wall materials. This investigation has been prompted by studies which show gross differences in crack growth characteristics of creep rupture specimens testing by postirradiation versus dynamic in-reactor methods. The experiment utilizes miniature center-cracked-tension specimens developed specifically for in-reactor studies. In the test, a chain of eight specimens, precracked to various initial crack lengths, is stressed during irradiation to determine crack growth rate as a function of stress intensity. Load levels were chosen which result in small crack growth rates encompassing a regime of the crack growth curve not previously investigated during irradiation studies of FCP. The test will be conducted on 20% cold worked 316 stainless steel at a temperature of 425 0 C, in a sodium environment, and at a frequency of 1 cycle/min. Irradiation will occur in the Oak Ridge Research Reactor, resulting in a He/dpa ratio similar to that expected at the first wall in a fusion reactor. Detailed design of the experiment is presented, along with crack growth data obtained from prototypic testing of the experimental apparatus. These results are compared to data obtained under similar conditions generated by conventional test methods

  17. Applicability of out-of-pile fretting wear tests to in-reactor fretting wear-induced failure time prediction

    Science.gov (United States)

    Kim, Kyu-Tae

    2013-02-01

    In order to investigate whether or not the grid-to-rod fretting wear-induced fuel failure will occur for newly developed spacer grid spring designs for the fuel lifetime, out-of-pile fretting wear tests with one or two fuel assemblies are to be performed. In this study, the out-of-pile fretting wear tests were performed in order to compare the potential for wear-induced fuel failure in two newly-developed, Korean PWR spacer grid designs. Lasting 20 days, the tests simulated maximum grid-to-rod gap conditions and the worst flow induced vibration effects that might take place over the fuel life time. The fuel rod perforation times calculated from the out-of-pile tests are greater than 1933 days for 2 μm oxidized fuel rods with a 100 μm grid-to-rod gap, whereas those estimated from in-reactor fretting wear failure database may be about in the range of between 60 and 100 days. This large discrepancy in fuel rod perforation may occur due to irradiation-induced cladding oxide microstructure changes on the one hand and a temperature gradient-induced hydrogen content profile across the cladding metal region on the other hand, which may accelerate brittleness in the grid-contacting cladding oxide and metal regions during the reactor operation. A three-phase grid-to-rod fretting wear model is proposed to simulate in-reactor fretting wear progress into the cladding, considering the microstructure changes of the cladding oxide and the hydrogen content profile across the cladding metal region combined with the temperature gradient. The out-of-pile tests cannot be directly applicable to the prediction of in-reactor fretting wear-induced cladding perforations but they can be used only for evaluating a relative wear resistance of one grid design against the other grid design.

  18. Globe Rupture

    Directory of Open Access Journals (Sweden)

    Reid Honda

    2017-07-01

    Full Text Available History of present illness: A 46-year-old male presented to the emergency department (ED with severe left eye pain and decreased vision after tripping and striking the left side of his head on the corner of his wooden nightstand. The patient arrived as an inter-facility transfer for a suspected globe rupture with a protective eye covering in place; thus, further physical examination of the eye was not performed by the emergency physician in order to avoid further leakage of aqueous humor. Significant findings: The patient’s computed tomography (CT head demonstrated a deformed left globe, concerning for ruptured globe. The patient had hyperdense material in the posterior segment (see green arrow, consistent with vitreous hemorrhage. CT findings that are consistent with globe rupture may include a collapsed globe, intraocular air, or foreign bodies. Discussion: A globe rupture is a full-thickness defect in the cornea, sclera, or both.1 It is an ophthalmologic emergency. Globe ruptures are almost always secondary to direct perforation via a penetrating mechanism; however, it can occur due to blunt injury if the force generated creates sufficient intraocular pressure to tear the sclera.2 Globes most commonly rupture at the insertions of the intraocular muscles or at the limbus. They are associated with a high rate of concomitant orbital floor fractures.2,3 Possible physical examination findings include a shallow anterior chamber on slit-lamp exam, hyphema, and an irregular “teardrop” pupil. Additionally, a positive Seidel sign, which is performed by instilling fluorescein in the eye and then examining for a dark stream of aqueous humor, is indicative of a globe rupture.4 CT is often used to assess for globe rupture; finds of a foreign body, intraocular air, abnormal contour or volume of the globe, or disruption of the sclera suggest globe rupture.2 The sensitivity of CT scan for diagnosis of globe rupture is only 75%; thus, high clinical

  19. Ruptured Spleen

    Science.gov (United States)

    ... be caused by various underlying problems, such as mononucleosis and other infections, liver disease, and blood cancers. ... cause a ruptured spleen. For instance, people with mononucleosis — a viral infection that can cause an enlarged ...

  20. Splenic rupture masquerading ruptured ectopic pregnancy | Kigbu ...

    African Journals Online (AJOL)

    The classical triad of presentation of delayed menses, irregular vaginal bleeding and abdominal pain may not be encountered at all! Overwhelming features of abdominal pain, amenorrhea, pallor, abdominal tenderness, shifting dullness with positive pregnancy test gave a clinical diagnosis of ruptured ectopic pregnancy.

  1. Mechanical testing of newly developed biomaterial designed for intra-articular reinforcement of partially ruptured cranial cruciate ligament: ex vivo pig model

    Directory of Open Access Journals (Sweden)

    Petra Fedorová

    2014-01-01

    Full Text Available The study deals with mechanical testing of newly developed material polyethylene terephtalate coated with polycaprolactone nanofibers in combination with biodagradable Hexalon ACL/PCL screws as a new possibility of intra-articular reinforcement of partially ruptured cranial cruciate ligament. Four groups of ex vivo models of pig stifle joints were prepared and tested: a model with intact CCL (group 1, a model with partial CCL rupture (group 2, a model with CCL rupture stabilized with 7 mm Mersilene® strip (group 3, and a model with CCL rupture stabilized with 5 mm PET/PCL biomaterial strip (group 4. The models were loaded in the standing angle of 100° and the maximum load (N and the shift (mm were monitored. The mean maximum peak power and the shift were 1266.0 ± 146.9 N and 13.7 ± 2.5 mm for group 1, and 1164.7 ± 228.2 N and 1 6.8 ± 3.3 mm for group 2, respectively. In all cases after reaching the maximum load, a tibial fracture occurred but never a CCL rupture. In groups 3 and 4, the initial fixation failure occurred in the mean values of 375.7 ± 81.5 and 360.4 ± 52.0 N, respectively, and with a bigger shift of 52.3 ± 11.9 mm and 39.4 ± 14.6 mm, respectively, compared to group 1. A critical point of failure was the anchoring in the bone. It can be concluded that the PET/PCL substitute in the ex vivo model has mechanically comparable properties with the clinically used Mersilene®, and based on its proven ability to carry stem cells it could be appropriate for partially ruptured CCL protection.

  2. Coincident steam generator tube rupture and stuck-open safety relief valve carryover tests: MB-2 steam generator transient response test program

    International Nuclear Information System (INIS)

    Garbett, K.; Mendler, O.J.; Gardner, G.C.; Garnsey, R.; Young, M.Y.

    1987-03-01

    In PWR steam generator tube rupture (SGTR) faults, a direct pathway for the release of radioactive fission products can exist if there is a coincident stuck-open safety relief valve (SORV) or if the safety relief valve is cycled. In addition to the release of fission products from the bulk steam generator water by moisture carryover, there exists the possibility that some primary coolant may be released without having first mixed with the bulk water - a process called primary coolant bypassing. The MB-2 Phase II test program was designed specifically to identify the processes for droplet carryover during SGTR faults and to provide data of sufficient accuracy for use in developing physical models and computer codes to describe activity release. The test program consisted of sixteen separate tests designed to cover a range of steady-state and transient fault conditions. These included a full SGTR/SORV transient simulation, two SGTR overfill tests, ten steady-state SGTR tests at water levels ranging from very low levels in the bundle up to those when the dryer was flooded, and three moisture carryover tests without SGTR. In these tests the influence of break location and the effect of bypassing the dryer were also studied. In a final test the behavior with respect to aerosol particles in a dry steam generator, appropriate to a severe accident fault, was investigated

  3. In-reactor testing of the closed cycle gas core reactor---the nuclear light bulb concept

    International Nuclear Information System (INIS)

    Gauntt, R.O.; Slutz, S.A.; Harms, G.A.; Latham, T.S.; Roman, W.C.; Rodgers, R.J.

    1993-01-01

    The Nuclear Light Bulb (NLB) concept is an advanced closed cycle space propulsion rocket engine design that offers unprecidented performance characteristics in terms of specific impulse (>1800 s) and thrust (>445 kN). The NLB is a gas-core nuclear reactor making use of thermal radiation from a high temperature U-plasma core to heat the hydrogen propellant to very high temperatures (∼4000 K). The following paper describes analyses performed in support of the design of in-reactor tests that are planned to be performed in the Annular Core Research Reactor (ACRR) at Sandia National Laboratories in order to demonstrate the technical feasibility of this advanced concept. The tests will examine the stability of a hydrodynamically confined fissioning U-plasma under steady and transient conditions. Testing will also involve study of propellant heating by thermal radiation from the plasma and materials performance in the nuclear environment of the NLB. The analyses presented here include neutronic performance studies and U-plasma radiation heat-transport studies of small vortex-confined fissioning U-plasma experiments that are irradiated in the ACRR. These analyses indicate that high U-plasma temperatures (4000 to 9000 K) can be sustained in the ACRR for periods of time on the order of 5 to 20 s. These testing conditions are well suited to examine the stability and performance requirements necessary to demonstrate the feasibility of this concept

  4. Fuel rod-grid interaction wear: in-reactor tests (LWBR development program)

    International Nuclear Information System (INIS)

    Stackhouse, R.M.

    1979-11-01

    Wear of the Zircaloy cladding of LWBR irradiation test fuel rods, resulting from relative motion between rod and rod support contacts, is reported. Measured wear depths were small, 0.0 to 2.7 mils, but are important in fuel element behavior assessment because of the local loss of cladding thickness, as well as the effect on grid spring forces that laterally restrain the rods. An empirical wear analysis model, based on out-of-pile tests, is presented. The model was used to calculate the wear on the irradiation test fuel rods attributed to a combination of up-and-down motions resulting from power and pressure/temperature cycling of the test reactor, flow-induced vibrations, and assembly handling scratches. The calculated depths are generally deeper than the measured depths

  5. Creep-rupture tests on chromium-containing conventional and ODS steels in oxygen-controlled Pb and air at 650 °C

    International Nuclear Information System (INIS)

    Yurechko, Mariya; Schroer, Carsten; Wedemeyer, Olaf; Skrypnik, Aleksandr; Konys, Jürgen

    2014-01-01

    Highlights: • Generally superior creep performance of ODS steels with 12–14% Cr is indicated. • Strength of 9Cr-ODS at 650°C approaches conventional 9Cr steels at decreasing load. • ODS steels show brittle primary and ductile residual fracture. • Apparent link between secondary creep rate and fracture mode of ODS steels. • Clear impact of liquid Pb at low load, corresponding to long time-to-rupture. - Abstract: Conventional martensitic steels with 9 mass% chromium (Cr), namely T91 and P92, and ODS steels with 9, 12 and 14 mass% Cr, respectively, were subjected to creep-rupture tests in stagnant oxygen-controlled lead (Pb) at 650 °C and c o = 10 −6 mass% dissolved oxygen. The 9Cr conventional steels were tested in the liquid metal at static engineering stress in the range from 75 to 200 MPa. 12 and 14Cr ODS were tested at 190–400 MPa, and 9Cr ODS at 75–300 MPa. Reference tests in stagnant air were carried out in the same stress ranges. The ODS steels with 12 or 14 mass% Cr, mainly tested in oxygen containing Pb, clearly exhibit a change in the stress-dependence of secondary creep rate and appearance of fracture surface at 330–400 MPa. No such change has been observed for 9Cr ODS so far. The conventional martensitic steel P92 shows a significant drop in creep strength accompanied by reduced necking and a change from ductile to brittle fracture when tested in Pb at 75 MPa (time-to-rupture t R = 13,090 h)

  6. Discrimination of DPRK M5.1 February 12th, 2013 Earthquake as Nuclear Test Using Analysis of Magnitude, Rupture Duration and Ratio of Seismic Energy and Moment

    Science.gov (United States)

    Salomo Sianipar, Dimas; Subakti, Hendri; Pribadi, Sugeng

    2015-04-01

    On February 12th, 2013 morning at 02:57 UTC, there had been an earthquake with its epicenter in the region of North Korea precisely around Sungjibaegam Mountains. Monitoring stations of the Preparatory Commission for the Comprehensive Nuclear Test-Ban Treaty Organization (CTBTO) and some other seismic network detected this shallow seismic event. Analyzing seismograms recorded after this event can discriminate between a natural earthquake or an explosion. Zhao et. al. (2014) have been successfully discriminate this seismic event of North Korea nuclear test 2013 from ordinary earthquakes based on network P/S spectral ratios using broadband regional seismic data recorded in China, South Korea and Japan. The P/S-type spectral ratios were powerful discriminants to separate explosions from earthquake (Zhao et. al., 2014). Pribadi et. al. (2014) have characterized 27 earthquake-generated tsunamis (tsunamigenic earthquake or tsunami earthquake) from 1991 to 2012 in Indonesia using W-phase inversion analysis, the ratio between the seismic energy (E) and the seismic moment (Mo), the moment magnitude (Mw), the rupture duration (To) and the distance of the hypocenter to the trench. Some of this method was also used by us to characterize the nuclear test earthquake. We discriminate this DPRK M5.1 February 12th, 2013 earthquake from a natural earthquake using analysis magnitude mb, ms and mw, ratio of seismic energy and moment and rupture duration. We used the waveform data of the seismicity on the scope region in radius 5 degrees from the DPRK M5.1 February 12th, 2013 epicenter 41.29, 129.07 (Zhang and Wen, 2013) from 2006 to 2014 with magnitude M ≥ 4.0. We conclude that this earthquake was a shallow seismic event with explosion characteristics and can be discriminate from a natural or tectonic earthquake. Keywords: North Korean nuclear test, magnitude mb, ms, mw, ratio between seismic energy and moment, ruptures duration

  7. Creep-rupture-test on the stainless steel X6CRNI1811 (DIN 1.4948) in the frame of the ''Extrapolation-Program''. (Part III)

    International Nuclear Information System (INIS)

    Solano, R.; Las Rivas, M. de; Barroso, S.

    1982-01-01

    The austenitic stainless steel X6CrNi1811 (DIN 1.4948) used as a structure material for the German Fast Breeder Reactor SNR 300 was creep tested in a temperature range of 550-650 deg under base material condition as well as welded material condition. The main point of this program (''Extrapolation-Program'') lies in the knowledge of the creep-rupture-strength and creepbehaviour up to 3 x 10 4 hours at higher temperatures in order to extrapolate up to >=10 5 hours for operating temperatures. In order to study the stress dependency of the minimum creep rate additional tests were carried out of 550 deg - 750 deg C. The present report describes the state in the running program with test-times of 23.000 hours and results from tests up to 55.000 hours belonging to other parallel programs are taken into account. Besides the creep-rupture behaviour it is also made a study of ductility between 550 and 750 deg C. Extensive metallographic examinations have been made to study the fracture behaviour and changes in structure. (author)

  8. Creep-rupture-test on the stainless steel X6crni1811 (Din 1.494.8) in the frame of the Extrapolation-Program. (Part III)

    International Nuclear Information System (INIS)

    Solano, R.; Schirra, M.; Rivas, M. de la; Barroso, S.; Seith, B.

    1982-01-01

    The austenitic stainless steel X6crni1811 (Din 1.4948) used as a structure material for the German Fast Breeder Reactor SNR 300 was creep tested in a temperature range of 550-650 degree centigree material condition as well as welded material condition. The main point of this program (Extrapolation-Program) lies in the knowledge of the creep-rupture-strength and creep-behaviour up to 3 x 10 4 hours higher temperatures in order to extrapolated up to ≥10 5 hours for operating temperatures. In order to study the stress dependency of the minimum creep rate additional tests were carried out of 550 degree centigree - 750 degree centigree. The present report describes the state in the running program with test-times of 23.000 hours and results from tests up to 55.000 hours belonging to other parallel programs are taken into account. Besides the creep-rupture behaviour it is also made a study of ductility between 550 and 750 degree centigree. Extensive metallographic examinations have been made to study the fracture behaviour and changes in structure. (Author)

  9. Description of the blowdown test facility COG program on in-reactor fission product release, transport, and deposition under severe accident conditions

    International Nuclear Information System (INIS)

    Fehrenbach, P.J.; Wood, J.C.

    1987-06-01

    Loss-of-coolant accidents with additional impairment of emergency cooling would probably result in high fuel temperatures leading to severe fuel damage (SFD) and significant fission product activity would then be transported along the PHTS to the break where a fraction of it would be released and transport under such conditions, there are many interacting and sometimes competing phenomena to consider. Laboratory simulations are being used to provide data on these individual phenomena, such as UO 2 oxidation and Zr-UO 2 interaction, from which mathematical models can be constructed. These are then combined into computer codes to include the interaction effects and assess the overall releases. In addition, in-reactor tests are the only source of data on release and transport of short-lived fission product nuclides, which are important in the consequence analysis of CANDU reactor accidents. Post-test decontamination of an in-reactor test facility also provides a unique opportunity to demonstrate techniques and obtain decontamination data relevant to post-accident rehabilitation of CANDU power reactors. Specialized facilities are required for in-reactor testing because of the extensive release of radioactive fission products and the high temperatures involved (up to 2500 degrees Celsius). To meet this need for the Canadian program, the Blowdown Test Facility (BTF) has been built in the NRU reactor at Chalk River. Between completion of construction in mid-1987 and the first Zircaloy-sheathed fuel test in fiscal year 1987/88, several commissioning tests are being performed. Similarly, extensive development work has been completed to permit application of instrumentation to irradiated fuel elements, and in support of post-test fuel assembly examination. A program of decontamination studies has also been developed to generate information relevant to post-accident decontamination of power reactors. The BTF shared cost test program funded by the COG High Temperature

  10. Accuracy and cost-analysis of placental alpha-microglobulin-1 test in the diagnosis of premature rupture of fetal membranes in resource-limited community settings.

    Science.gov (United States)

    Eleje, George Uchenna; Ezugwu, Euzebus Chinonye; Ogunyemi, Dotun; Eleje, Lydia Ijeoma; Ikechebelu, Joseph Ifeanyichukwu; Igwegbe, Anthony Osita; Okonkwo, John E; Ikpeze, Okechukwu Christian; Udigwe, Gerald Okanandu; Onah, Hyacinth Eze; Nwosu, Betrand Obi; Ezeama, Chukwuemeka Okwudili; Ezenkwele, Eziamaka Pauline

    2015-01-01

    To determine accuracy and costs of placental α-microglobulin-1 (PAMG-1) test compared to standard clinical assessment (SCA) for diagnosing rupture of membranes (ROM). A multicenter double-blind study of consecutive women with symptoms and signs of ROM in Nnamdi Azikiwe University Teaching Hospital, Nnewi and University of Nigeria Teaching Hospital, Enugu, both in south-east Nigeria using SCA for ROM and the PAMG-1 test was done. ROM was diagnosed if two out of three methods from SCA (pooling, positive nitrazine test or ferning) were present and confirmed post-delivery based on presence of any two of these clinical criteria: delivery in 48 h to 7 days, evidence of chorioamnionitis, membranes overtly ruptured at delivery and adverse perinatal outcomes strongly correlated with prolonged PROM. A cost-analysis was also done. The outcome measures included sensitivity, specificity, accuracy and costs for the two tests. Accuracy, sensitivity and specificity for the PAMG-1 test were 97.2%, 97.4% and 96.7%, higher than for SCA which were 83.7%, 87.9% and 70.5%, respectively (P < 0.001). Accuracy of SCA was higher at less than 34 weeks than 34 weeks or more (88.3% vs 81.4%) while the PAMG-1 test performed equally at both gestational age categories (96.1% vs 97.7%). In women without pooling, accuracy of the PAMG-1 test was 96.7%, while it was 40.0% with SCA. Analysis showed that the overall cost of SCA was 45% higher than the PAMG-1 test. This study confirms that the PAMG-1 test has a consistently high diagnostic accuracy at all gestational ages and with equivocal cases of ROM. The PAMG-1 test appears less costly than SCA. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  11. Creep-rupture-tests on thestainless steel X6 CrNi1811 (DIN 1.4948) in the frame of the ''Extrapolation-Program'' Pt. 2

    International Nuclear Information System (INIS)

    Solano, R.R.; Barroso, S.; Rivas, M. de las; Schirra, M.; Seith, B.

    1979-01-01

    The austenitic stainless steel X6 CrNi 1811 (DIN 1.4948) that is used as a structure material for the German Fast Breeder Reactor SNR 300 was creep tested in a temperature range of 550-650 deg under base material condition as well as welded material condition. The main point of this program (''Extrapolation-Program'') lies in the knowledge of the cree-rupture-strength and creep-behaviour up to 3X10 - 4 hours at higher temperatures in order to extrapolate up to (>=)10 5 hours for operating temperatures. In order to study the stress dependency of the minimum creep rate additional tests were carried out over temperature range 550 deg - 750 deg C. The present report describes the state in the running program with test-time up to 35.000 hours. Besides the cree-rupture behaviour it is possible to make a distinct quantitative statement for the creep-behaviour and ductility. Extensive metallographic examinations show the fracture behaviour and changes in structure. (author)

  12. Variability in creep and rupture test results in a single heat of type 304 stainless steel. R and D report LR:75:4213-01:3

    International Nuclear Information System (INIS)

    Leyda, W.E.; Schultz, C.C.

    1975-09-01

    Results of uniaxial creep and rupture tests, from a single heat of type 304 stainless steel, are examined to determine the reasons for their greater-than-expected variability. The test results were obtained as part of a program to develop and verify high temperature structural design methods for liquid metal fast breeder reactor system components. A single heat of material (heat 9T2796) is being used throughout the program, by all investigators and in several product forms, to minimize the problem of heat-to-heat variations in elevated temperature behavior. The same laboratory reanneal was specified for each product form to reduce differences in behavior among the several being used. The data discussed was obtained from the 5/8-inch diameter, hot-rolled bar product form. The laboratory reanneal was performed after finish machining to minimize specimen-to-specimen differences. In spite of these efforts to reduce data variability, significant scatter was observed in both short-time and long-time deformation response, and also in time-to-rupture results

  13. IFPE/MT4-MT6A-LOCA, Large-break LOCA in-reactor fuel bundle materials tests at NRU

    International Nuclear Information System (INIS)

    Cunningham, Mitchel E.; Turnbull, J.A.

    2003-01-01

    Description - Objectives - Results: The U.S. Nuclear Regulatory Commission (NRC) conducted a series of thermal-hydraulic and cladding mechanical deformation tests in the National Research Universal (NRU) reactor at the Chalk River National Laboratory in Canada. The objective of these tests was to perform simulated loss-of-coolant-accident (LOCA) experiments using full-length light-water reactor fuel rods to study mechanical deformation, flow blockage, and coolability. Three phases of a LOCA (i.e., heat-up, reflood, and quench) were performed in situ using nuclear fissioning to simulate the low-level decay power during a LOCA after shutdown. All tests used PWR-type, non-irradiated fuel rods. Provided here is information on two materials tests, MT-6A and MT-4, which PNNL considers the better characterized for the purposes of setting up computer cases. The NRU reactor is a heterogeneous, thermal, tank-type research reactor. It has a power level of 135 MWth and is heavy-water moderated and cooled. The coolant has an inlet temperature of 310 K at a pressure of 0.65 MPa. The MT tests were conducted in a specially designed test train to supply the specified coolant conditions of flowing steam, stagnant steam, and then reflood. Typical instrumentation for the MT tests included fuel centerline thermocouples, cladding inner surface thermocouples, cladding outer surface thermocouples, rod internal gas pressure transducers or pressure switches, coolant channel steam probes, and self-powered neutron detectors. This instrumentation allowed for determining rupture times and cladding temperature. The test rods for the LOCA cases in the NRU reactor were irradiated in flowing steam prior to the transient, stagnant steam during the transient and prior to reflood, and then reflood conditions to complete the transient. Both cladding inner surface and outer surface temperatures were measured, in addition to coolant temperatures. However, only cladding inner surface temperatures were

  14. Preliminary results of the BTF-104 experiment: an in-reactor test of fuel behaviour and fission-product release and transport under LOCA/LOECC conditions

    Energy Technology Data Exchange (ETDEWEB)

    Dickson, L W; Elder, P H; Devaal, J W; Irish, J D; Yamazaki, A R [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    The BTF-104 experiment is one of a series of in-reactor tests being performed to measure fuel behaviour and fission-product release from nuclear fuel subjected to accident conditions. The primary objective of the BTF-104 experiment was to measure fission-product releases from a CANDU-sized fuel element under combined Loss-of-Coolant Accident (LOCA) and Loss-of-Emergency-Core-Cooling (LOECC) conditions at an average fuel temperature of about 1550 deg C. The preliminary results of the BTF-104 experiment are presented in this paper. (author). 6 refs., 12 figs.

  15. Predicting creep rupture from early strain data

    International Nuclear Information System (INIS)

    Holmstroem, Stefan; Auerkari, Pertti

    2009-01-01

    To extend creep life modelling from classical rupture modelling, a robust and effective parametric strain model has been developed. The model can reproduce with good accuracy all parts of the creep curve, economically utilising the available rupture models. The resulting combined model can also be used to predict rupture from the available strain data, and to further improve the rupture models. The methodology can utilise unfailed specimen data for life assessment at lower stress levels than what is possible from rupture data alone. Master curves for creep strain and rupture have been produced for oxygen-free phosphorus-doped (OFP) copper with a maximum testing time of 51,000 h. Values of time to specific strain at given stress (40-165 MPa) and temperature (125-350 deg. C) were fitted to the models in the strain range of 0.1-38%. With typical inhomogeneous multi-batch creep data, the combined strain and rupture modelling involves the steps of investigation of the data quality, extraction of elastic and creep strain response, rupture modelling, data set balancing and creep strain modelling. Finally, the master curves for strain and rupture are tested and validated for overall fitting efficiency. With the Wilshire equation as the basis for the rupture model, the strain model applies classical parametric principles with an Arrhenius type of thermal activation and a power law type of stress dependence for the strain rate. The strain model also assumes that the processes of primary and secondary creep can be reasonably correlated. The rupture model represents a clear improvement over previous models in the range of the test data. The creep strain information from interrupted and running tests were assessed together with the rupture data investigating the possibility of rupture model improvement towards lower stress levels by inverse utilisation of the combined rupture based strain model. The developed creep strain model together with the improved rupture model is

  16. Strength and rupture-life transitions caused by secondary carbide precipitation in HT-9 during high-temperature low-rate mechanical testing

    International Nuclear Information System (INIS)

    DiMelfi, R.J.; Gruber, E.E.; Kramer, J.M.; Hughes, T.H.

    1992-01-01

    The martensitic-ferritic alloy HT-9 is slated for long-term use as a fuel-cladding material in the Integral Fast Reactor. Analysis of published high-temperature mechanical property data suggests that secondary carbide precipitation would occur during service life causing substantial strengthening of the as-heat-treated material. Aspects of the kinetics of this precipitation process are extracted from calculations of the back stress necessary to produce the observed strengthening effect under various creep loading conditions. The resulting Arrhenius factor is shown to agree quantitatively with shifts to higher strength of crept material in reference to the intrinsic strength of HT-9. The results of very low constant strain-rate high-temperature tensile tests on as-heat-treated HT-9 that focus on the transition in strength with precipitation will be presented and related to rupture-life

  17. Rupture properties

    International Nuclear Information System (INIS)

    Marandet, B.; Sanz, G.

    1977-01-01

    Linear elastic fracture mechanics can be applied to medium strength steels when they are used in large thicknesses. In this case it is possible to put in evidence the existence of a parameter, Ksub(Ic), characteristic of the material, which depends only on the strain rate and the temperature, and which can be used to predict quantitatively the conditions for fracture of a structure containing a defect. The determination of Ksub(Ic) involves the use of large specimens, and thus of big testing machines. It is then clear that such tests can not be performed systematically on many steels, and certainly not at all in metallurgical quality control. The aim of this study was to check and develop further certain new theories which make it possible, according to their authors, to evaluate Ksub(Ic) with small specimens: correlations between Ksub(Ic) and Charpy V toughness, J-integral, equivalent energy concept. As these techniques lead to values of toughness in plane-strain conditions, we have also studied the significance of R-curves, a concept which has be proposed to characterize the toughness of a material in plane-stress conditions. This report has thus been divided into four parts which correspond to the four approaches just mentionned

  18. Rupture of primigravid uterus and recurrent rupture

    Directory of Open Access Journals (Sweden)

    Nahreen Akhtar

    2016-08-01

    Full Text Available Uterine rupture is a deadly obstetrical emergency endangering the life of both mother and fetus. In Bangladesh, majority of deliveries arc attended by unskilled traditional birth attendant and maternal mortality is still quite high. It is rare Ln developed country but unfortunately it is common in a developing country like Bangladesh. We report a case history of a patient age 32yrs from Daudkandi, Comilla admitted with H/0 previous two rupture uterus and repair with no living issue. We did caesarean section at her 31+ weeks of pregnancy when she developed Jabour pain. A baby of 1.4 kg was delivered. During cesarean section, focal rupture was noted in previous scar of rupture. Unfortunately the baby expired in neonatal ICU after 36 hours.

  19. Hepatic rupture in preeclampsia

    International Nuclear Information System (INIS)

    Winer-Muram, H.T.; Muram, D.; Salazar, J.; Massie, J.D.

    1985-01-01

    The diagnosis of hepatic rupture in patients with pregnancy-induced hypertension (preeclampsia and eclampsia) is rarely made preoperatively. Diagnostic imaging can be utilized in some patients to confirm the preoperative diagnosis. Since hematoma formation precedes hepatic rupture, then, when diagnostic modalities such as sonography and computed tomography identify patients with hematomas, these patients are at risk of rupture, and should be hospitalized until the hematomas resolve

  20. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    Science.gov (United States)

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Biomechanical rupture risk assessment of abdominal aortic aneurysms based on a novel probabilistic rupture risk index.

    Science.gov (United States)

    Polzer, Stanislav; Gasser, T Christian

    2015-12-06

    A rupture risk assessment is critical to the clinical treatment of abdominal aortic aneurysm (AAA) patients. The biomechanical AAA rupture risk assessment quantitatively integrates many known AAA rupture risk factors but the variability of risk predictions due to model input uncertainties remains a challenging limitation. This study derives a probabilistic rupture risk index (PRRI). Specifically, the uncertainties in AAA wall thickness and wall strength were considered, and wall stress was predicted with a state-of-the-art deterministic biomechanical model. The discriminative power of PRRI was tested in a diameter-matched cohort of ruptured (n = 7) and intact (n = 7) AAAs and compared to alternative risk assessment methods. Computed PRRI at 1.5 mean arterial pressure was significantly (p = 0.041) higher in ruptured AAAs (20.21(s.d. 14.15%)) than in intact AAAs (3.71(s.d. 5.77)%). PRRI showed a high sensitivity and specificity (discriminative power of 0.837) to discriminate between ruptured and intact AAA cases. The underlying statistical representation of stochastic data of wall thickness, wall strength and peak wall stress had only negligible effects on PRRI computations. Uncertainties in AAA wall stress predictions, the wide range of reported wall strength and the stochastic nature of failure motivate a probabilistic rupture risk assessment. Advanced AAA biomechanical modelling paired with a probabilistic rupture index definition as known from engineering risk assessment seems to be superior to a purely deterministic approach. © 2015 The Author(s).

  2. Eccentric pressurized tube for measuring creep rupture

    International Nuclear Information System (INIS)

    Schwab, P.R.

    1981-01-01

    Creep rupture is a long term failure mode in structural materials that occurs at high temperatures and moderate stress levels. The deterioration of the material preceding rupture, termed creep damage, manifests itself in the formation of small cavities on grain boundaries. To measure creep damage, sometimes uniaxial tests are performed, sometimes density measurements are made, and sometimes the grain boundary cavities are measured by microscopy techniques. The purpose of the present research is to explore a new method of measuring creep rupture, which involves measuring the curvature of eccentric pressurized tubes. Theoretical investigations as well as the design, construction, and operation of an experimental apparatus are included in this research

  3. Predictive value of vaginal IL-6 and TNFα bedside tests repeated until delivery for the prediction of maternal-fetal infection in cases of premature rupture of membranes.

    Science.gov (United States)

    Kayem, Gilles; Batteux, Frederic; Girard, Noémie; Schmitz, Thomas; Willaime, Marion; Maillard, Francoise; Jarreau, Pierre Henri; Goffinet, Francois

    2017-04-01

    Examine the predictive value for maternal-fetal infection of routine bedside tests detecting the proinflammatory cytokines, TNFα and IL-6, in the vaginal secretions of women with premature rupture of the membranes (PROM). This prospective two-center cohort study included all women hospitalized for PROM over a 2-year period. A bedside test assessed IL-6 and TNFα in vaginal secretions. Both centers routinely tested CRP and leukocytes, assaying both in maternal serum, and analyzed vaginal bacterial flora; all samples were repeated twice weekly until delivery. The study included 689 women. In cases of preterm PROM (PPROM) before 37 weeks (n=184), a vaginal sample positive for one or more bacteria was the only marker associated with early neonatal infection (OR 5.6, 95%CI; 2.0-15.7). Its sensitivity was 82% (95%CI; 62-94) and its specificity 56% (95%CI; 47-65). All positive markers of infection were associated with the occurrence of chorioamnionitis. In cases of PROM from 37 weeks onward (n=505), only CRP >5mg/dL was associated with early neonatal infection (OR=8.3, 95%CI; 1.1-65.4) or clinical chorioamnionitis (OR=6.8, 95%CI; 1.5-30.0). The sensitivity of CRP >5mg/dL was 91% (95%CI; 59-100) and its specificity 45% (95%CI; 40-51) for predicting early neonatal infection, and 89% (95%CI; 65-99) and 46% (95%CI; 41-51), respectively, for predicting clinical chorioamnionitis. The association of vaginal cytokines with maternal-fetal infection is weak and thus prevents their use as a good predictor of maternal-fetal infection. CRP and vaginal samples may be useful for identifying a group of women at low risk of infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Development of rupture discs for the FBTR

    International Nuclear Information System (INIS)

    Chetal, S.C.; Raju, C.; Anandkumar, V.; Seetharaman, V.; Rajan, K.K.

    1984-01-01

    Rupture discs are required as a safety device for protecting the secondary sodium circuit and its components against high pressure surges due to accidental water steam leaks in sodium heated steam generator and the consequent sodium water reaction. For identical reasons, rupture discs are also required on the vessels used for decontamination of sodium components. Reverse buckling knife blade concept with austenitic stainless steel disc has been developed for the rupture disc assemblies required for Fast Breeder Test Reactor (FBTR). Hydroforming process without any die has been used for disc fabrication. One rupture disc assembly required for steam generator is undergoing sodium endurance test and has accumulated 4,500 hours. The present status of development work as demonstrated by room temperature experimental results as well as the scope for future work are discussed. (author)

  5. Research and tests of steel-concrete-steel sandwich composite shear wall in reactor containment of HTR-PM

    International Nuclear Information System (INIS)

    Sun Yunlun; Huang Wen; Zhang Ran; Zhang Pei; Tian Chunyu

    2014-01-01

    By quasi-static test of 8 specimens of steel-concrete-steel sandwich composite shear wall, the bearing capacity, hysteretic behavior, failure mode of the specimens was studied. So was the effect of the shear-span ratios, steel ratios and spacing of studs on the properties of the specimens. The failure patterns of all specimens with different shear-span ratios between 1.0 and 1.5 were compression-bending failure. The hysteretic curves of all specimens were relatively plump, which validated the well deformability and energy dissipation capacity of the specimens. When shear-span ratio less than 1.5, the shear property of the steel plate was well played, and so was the deformability of the specimens. The bigger the steel ratio was, the better the lateral resistance capacity and the deformability was. Among the spacing of studs in the test, the spacing of studs had no significant effect on the bearing capacity, deformability and ductility of the specimens. Based on the principle of superposition an advised formula for the compression-bending capacity of the shear wall was proposed, which fitted well with the test result and had a proper safety margin. (author)

  6. Irradiation creep and creep rupture of titanium-modified austenitic stainless steels and their dependence on cold work level

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Eiholzer, C.R.; Toloczko, M.B.; Kumar, A.S.

    1991-11-01

    A titanium-modified austenitic type stainless steel was tested at three cold work levels to determine its creep and creep rupture properties under both thermal aging and neutron irradiation conditions. Both the thermal and irradiation creep behavior exhibit a complex non-monotonic relationship with cold work level that reflects the competition between a number of stress-sensitive and temperature-dependent microstructural processes. Increasing the degree of cold work to 30% from the conventional 20% level was detrimental to its performance, especially for applications above 550 degrees c. The 20% cold work level is preferable to the 10% level, in terms of both in-reactor creep rupture response and initial strength

  7. Behavior of underclad cracks in reactor pressure vessels - evaluation of mechanical analyses with tests on cladded mock-ups

    International Nuclear Information System (INIS)

    Moinereau, D.; Rousselier, G.; Bethmont, M.

    1993-01-01

    Innocuity of underclad flaws in the reactor pressure vessels must be demonstrated in the French safety analyses, particularly in the case of a severe transient at the end of the pressure vessel lifetime, because of the radiation embrittlement of the vessel material. Safety analyses are usually performed with elastic and elasto-plastic analyses taking into account the effect of the stainless steel cladding. EDF has started a program including experiments on large size cladded specimens and their interpretations. The purpose of this program is to evaluate the different methods of fracture analysis used in safety studies. Several specimens made of ferritic steel A508 C1 3 with stainless steel cladding, containing small artificial defects, are loaded in four-point bending. Experiments are performed at very low temperature to simulate radiation embrittlement and to obtain crack instability by cleavage fracture. Three tests have been performed on mock-ups containing a small underclad crack (with depth about 5 mn) and a fourth test has been performed on one mock-up with a larger crack (depth about 13 mn). In each case, crack instability occurred by cleavage fracture in the base metal, without crack arrest, at a temperature of about - 170 deg C. Each test is interpreted using linear elastic analysis and elastic-plastic analysis by two-dimensional finite element computations. The fracture are conservatively predicted: the stress intensity factors deduced from the computations (K cp or K j ) are always greater than the base metal toughness. The comparison between the elastic analyses (including two plasticity corrections) and the elastic-plastic analyses shows that the elastic analyses are often conservative. The beneficial effect of the cladding in the analyses is also shown : the analyses are too conservative if the cladding effects is not taken into account. (authors). 9 figs., 6 tabs., 10 refs

  8. Premature rupture of membranes

    Science.gov (United States)

    ... gov/ency/patientinstructions/000512.htm Premature rupture of membranes To use the sharing features on this page, ... water that surrounds your baby in the womb. Membranes or layers of tissue hold in this fluid. ...

  9. Ruptured submitral aneurysm

    Directory of Open Access Journals (Sweden)

    V. Shukla

    2016-09-01

    Full Text Available Submitral aneurysm is a rare entity, with around few hundred cases reported till date. Presentation can be varied. We describe here a case of submitral aneurysm in a young male with rupture into the left atrium cavity.

  10. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  11. Ruptured cornual pregnancy

    International Nuclear Information System (INIS)

    Hussain, M.; Yasmeen, H.; Noorani, K.

    2003-01-01

    A case of ruptured cornual pregnancy is presented here. The patient presented with history of 30 weeks gestational amenorrhoea and pain in the lower abdomen and epigastrium for the last seven days. Ultrasound revealed a 29 weeks abdominal pregnancy with blood in the pelvic cavity. On laparotomy; there was a ruptured right cornual pregnancy, treated cornual resection and uterine repair. An alive male baby of one kg weight was delivered from the resected cornua of the uterus. (author)

  12. Viscoelastic characterization of carbon fiber-epoxy composites by creep and creep rupture tests; Caracterizacao viscoelastica por meio de ensaios de fluencia e ruptura por fluencia de compositos polimericos de matriz de matriz de resina epoxidica e fibra de carbono

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Luis Claudio

    2009-07-01

    One of the main requirements for the use of fiber-reinforced polymer matrix composites in structural applications is the evaluation of their behavior during service life. The warranties of the integrity of these structural components demand a study of the time dependent behavior of these materials due to viscoelastic response of the polymeric matrix and of the countless possibilities of design configurations. In the present study, creep and creep rupture test in stress were performed in specimens of unidirectional carbon fiber-reinforced epoxy composites with fibers orientations of 60 degree and 90 degree, at temperatures of 25 and 70 degree C. The aim is the viscoelastic characterization of the material through the creep curves to some levels of constant tension during periods of 1000 h, the attainment of the creep rupture envelope by the creep rupture curves and the determination of the transition of the linear for non-linear behavior through isochronous curves. In addition, comparisons of creep compliance curves with a viscoelastic behavior prediction model based on Schapery equation were also performed. For the test, a modification was verified in the behavior of the material, regarding the resistance, stiffness and deformation, demonstrating that these properties were affected for the time and tension level, especially in work temperature above the ambient. The prediction model was capable to represent the creep behavior, however the determination of the equations terms should be considered, besides the variation of these with the applied tension and the elapsed time of test. (author)

  13. Pressure tube rupture in a closed tank

    International Nuclear Information System (INIS)

    Khater, H.A.; Hadaller, G.I.; Stern, F.

    1985-06-01

    A study has been prepared on the feasibility of conducting pressure tube/calandria tube rupture tests in a closed tank, simulating a scaled-down calandria vessel. The study includes: i) a review of previous work, ii) an analytical investigation of the scaling problem of the calandria vessel and relevant in-core structures, iii) selection of a method for initiating pressure tube/calandria tube rupture, iv) a set of specifications for the test assembly, v) general arrangement drawings, vi) a proposal for a test matrix, vii) a survey and evaluation of existing facilities which could provide the required high pressure, temperature and fluid inventory, and viii) a cost estimate for the detailed design and construction, instrumentation, data acquisition and reduction, testing and reporting. The study concludes that it is both technically and practically feasible to conduct pressure tube rupture tests in a closed tank

  14. Creep rupture behavior of unidirectional advanced composites

    Science.gov (United States)

    Yeow, Y. T.

    1980-01-01

    A 'material modeling' methodology for predicting the creep rupture behavior of unidirectional advanced composites is proposed. In this approach the parameters (obtained from short-term tests) required to make the predictions are the three principal creep compliance master curves and their corresponding quasi-static strengths tested at room temperature (22 C). Using these parameters in conjunction with a failure criterion, creep rupture envelopes can be generated for any combination of in-plane loading conditions and ambient temperature. The analysis was validated experimentally for one composite system, the T300/934 graphite-epoxy system. This was done by performing short-term creep tests (to generate the principal creep compliance master curves with the time-temperature superposition principle) and relatively long-term creep rupture tensile tests of off-axis specimens at 180 C. Good to reasonable agreement between experimental and analytical results is observed.

  15. Ruptured Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Valentina Park

    2016-09-01

    Full Text Available History of present illness: A 21-year-old female presented with sudden onset suprapubic abdominal pain associated with dysuria. The patient also experienced near syncope during bowel movements three times three days ago without falling or losing consciousness. She denied fever, nausea, and vomiting. She stated that she was five weeks pregnant by last menstrual period. She had an ultrasound a few weeks before that showed no intrauterine pregnancy, but she had not followed up for additional testing. Significant findings: The patient’s serum beta-hCG was 5,637 mIU/mL. The transvaginal ultrasound showed an empty uterus with free fluid posteriorly in the pelvis and Pouch of Douglas (00:00. A 4.5 cm heterogeneous mass was visible in the left adnexa concerning for an ectopic pregnancy (00:10. Discussion: Ectopic pregnancies are a leading cause of maternal morbidity and mortality, as well as decreased fertility.1,2 Differentiating between an ectopic pregnancy and a normal early pregnancy may be difficult, since ultrasound and quantitative beta-hCG may show inconclusive results.3,4 Patients who have used fertility treatment may further complicate the picture because they are at risk for heterotypic pregnancies.5 Ectopic pregnancies most commonly implant in the fallopian tube, but may alternatively implant in the ovary, cervix, abdomen, or uterine cornua.4 Ultrasonography may show an empty uterus, adnexal mass, pelvic free fluid, or an extra-uterine gestational sac, yolk sac, and/or embryo.6 Treatment options for ectopic pregnancy include surgery or methotrexate.2,4 Some patients may be candidates for close outpatient surveillance if the diagnosis is unclear or in very limited cases for early, non-ruptured ectopic pregnancies.2,4

  16. Rupture, waves and earthquakes.

    Science.gov (United States)

    Uenishi, Koji

    2017-01-01

    Normally, an earthquake is considered as a phenomenon of wave energy radiation by rupture (fracture) of solid Earth. However, the physics of dynamic process around seismic sources, which may play a crucial role in the occurrence of earthquakes and generation of strong waves, has not been fully understood yet. Instead, much of former investigation in seismology evaluated earthquake characteristics in terms of kinematics that does not directly treat such dynamic aspects and usually excludes the influence of high-frequency wave components over 1 Hz. There are countless valuable research outcomes obtained through this kinematics-based approach, but "extraordinary" phenomena that are difficult to be explained by this conventional description have been found, for instance, on the occasion of the 1995 Hyogo-ken Nanbu, Japan, earthquake, and more detailed study on rupture and wave dynamics, namely, possible mechanical characteristics of (1) rupture development around seismic sources, (2) earthquake-induced structural failures and (3) wave interaction that connects rupture (1) and failures (2), would be indispensable.

  17. Welded rupture disc assemblies for use in Tritium Research Laboratory

    International Nuclear Information System (INIS)

    Faltings, R.E.

    1976-01-01

    Welded rupture disc assemblies were investigated and developed in various ranges for probable use by experimenters in their activities in the Tritium Research Laboratory at Sandia Laboratories, Livermore. This study indicates that currently welded rupture disc assemblies with appropriate testing and installation by certified pressure installers may be used in pressure systems in the Tritium Research Laboratory and other areas at SLL

  18. The Danish anal sphincter rupture questionnaire: Validity and reliability

    DEFF Research Database (Denmark)

    Due, Ulla; Ottesen, Marianne

    2008-01-01

    Objective. To revise, validate and test for reliability an anal sphincter rupture questionnaire in relation to construct, content and face validity. Setting and background. Since 1996 women with anal sphincter rupture (ASR) at one of the public university hospitals in Copenhagen, Denmark have bee...

  19. Double rupture disc experience

    International Nuclear Information System (INIS)

    1979-01-01

    Result of these observations, comparisons and evaluations can be summarized in the following list of concerns regarding the use of double rupture discs coupled to the liquid space of a steam generator that is subjected to a large leak sodium water reaction event. Single rupture disc show delayed collapse characteristics in LLTR Series I and double disc assemblies are presumed to be more complex with additional delay before opening to give pressure relief. Delayed failure increases pressures in the IHTS and must be adequately covered by design requirements. With CRBR design, the first disc may fail only partially reducing the loading on the second disc with the result that relief performance may not meet requirements

  20. Diagnosis of foetal membrane ruptures: Placental alpha ...

    African Journals Online (AJOL)

    Context: Pre‑labour rupture of membranes (PROM) is a common obstetric complication which presents a diagnostic challenge, especially in equivocal ... problematic with the need to balance the risk of prematurity with that of prolonged ... array of rapid, minimally invasive tests based on biochemical markers in amniotic fluid ...

  1. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  2. Slow rupture of frictional interfaces

    OpenAIRE

    Sinai, Yohai Bar; Brener, Efim A.; Bouchbinder, Eran

    2011-01-01

    The failure of frictional interfaces and the spatiotemporal structures that accompany it are central to a wide range of geophysical, physical and engineering systems. Recent geophysical and laboratory observations indicated that interfacial failure can be mediated by slow slip rupture phenomena which are distinct from ordinary, earthquake-like, fast rupture. These discoveries have influenced the way we think about frictional motion, yet the nature and properties of slow rupture are not comple...

  3. Nuclide content in reactor waste

    International Nuclear Information System (INIS)

    1981-11-01

    Certain corrosion and fission products of importance in reactor waste management cannot be measured by gammaspectrometric techniques. In this study, a method is suggested by which the occurence of such nuclides can be quantitatively related to suitable gamma-emitters of similar origin. The method is tested by statistical analysis on the waste data recorded from two Swedish nuclear power plants. As this method is not applicable for Carbon-14, this nuclide was measured directly in spent ion exchange resins from three Finnish and Swedish power plants. (author)

  4. Slow rupture of frictional interfaces

    Science.gov (United States)

    Bar Sinai, Yohai; Brener, Efim A.; Bouchbinder, Eran

    2012-02-01

    The failure of frictional interfaces and the spatiotemporal structures that accompany it are central to a wide range of geophysical, physical and engineering systems. Recent geophysical and laboratory observations indicated that interfacial failure can be mediated by slow slip rupture phenomena which are distinct from ordinary, earthquake-like, fast rupture. These discoveries have influenced the way we think about frictional motion, yet the nature and properties of slow rupture are not completely understood. We show that slow rupture is an intrinsic and robust property of simple non-monotonic rate-and-state friction laws. It is associated with a new velocity scale cmin, determined by the friction law, below which steady state rupture cannot propagate. We further show that rupture can occur in a continuum of states, spanning a wide range of velocities from cmin to elastic wave-speeds, and predict different properties for slow rupture and ordinary fast rupture. Our results are qualitatively consistent with recent high-resolution laboratory experiments and may provide a theoretical framework for understanding slow rupture phenomena along frictional interfaces.

  5. Traumatic rupture of the aorta

    International Nuclear Information System (INIS)

    Dorfman, G.S.; Paolella, L.P.; Haas, R.A.; Lambiase, R.E.; Cronan, J.J.

    1988-01-01

    To evaluate the acceptability of digital subtraction angiography (DSA) in the evaluation of traumatic rupture of the aorta (TRA), the authors obtained 56 thoracic aortograms in 55 consecutive trauma patients, using both DSA and cut-film angiography (CFA). Both studies were ranked blindly and assigned scores for quality and diagnosis. Interobserver variance for DSA and CFA quality rankings was insignificant. CFA achieved significantly higher ranking for quality. In the 56 examinations, CFA demonstrated seven abnormalities that demanded intervention for follow-up angiography. DSA demonstrated only five of these and found no additional abnormalities. While this evaluation applies only to the particular digital system that the authors tested, they found that DSA, as compared with CFA, failed to demonstrate significant aortic injury. The confidence of diagnosis was significantly greater with CFA. Similar double-blind evaluation is mandatory at any trauma center prior to converting from CFA to DSA in the diagnosis of this life-threatening condition

  6. Retrieving rupture history using waveform inversions in time sequence

    Science.gov (United States)

    Yi, L.; Xu, C.; Zhang, X.

    2017-12-01

    The rupture history of large earthquakes is generally regenerated using the waveform inversion through utilizing seismological waveform records. In the waveform inversion, based on the superposition principle, the rupture process is linearly parameterized. After discretizing the fault plane into sub-faults, the local source time function of each sub-fault is usually parameterized using the multi-time window method, e.g., mutual overlapped triangular functions. Then the forward waveform of each sub-fault is synthesized through convoluting the source time function with its Green function. According to the superposition principle, these forward waveforms generated from the fault plane are summarized in the recorded waveforms after aligning the arrival times. Then the slip history is retrieved using the waveform inversion method after the superposing of all forward waveforms for each correspond seismological waveform records. Apart from the isolation of these forward waveforms generated from each sub-fault, we also realize that these waveforms are gradually and sequentially superimposed in the recorded waveforms. Thus we proposed a idea that the rupture model is possibly detachable in sequent rupture times. According to the constrained waveform length method emphasized in our previous work, the length of inverted waveforms used in the waveform inversion is objectively constrained by the rupture velocity and rise time. And one essential prior condition is the predetermined fault plane that limits the duration of rupture time, which means the waveform inversion is restricted in a pre-set rupture duration time. Therefore, we proposed a strategy to inverse the rupture process sequentially using the progressively shift rupture times as the rupture front expanding in the fault plane. And we have designed a simulation inversion to test the feasibility of the method. Our test result shows the prospect of this idea that requiring furthermore investigation.

  7. In-reactor creep of zirconium-2.5 wt% niobium at 570 K

    International Nuclear Information System (INIS)

    Coleman, C.E.; Causey, A.R.; Fidleris, V.

    1976-01-01

    The effect of fast neutron flux at 570 K on the creep rate of specimens of zirconium-2.5 wt% niobium alloy taken from tubes in various metallurgical conditions has been measured using both constant load tensile creep machines and bent-beam stress relaxation. Creep rates calculated from stress relaxation fit on the trend line for the constant load creep data. Between 114 MPa and 450 MPa the creep rate is proportional to neutron flux. The creep rate of specimens from the longitudinal direction is about twice that of specimens from the circumferential direction of a tube. This anisotropy in creep strength is attributed partly to crystallographic texture and partly to deformation substructure. Cold-work is detrimental to in-reactor creep strength; as-extruded material has higher creep strength. In cold-worked material at stresses below 100 MPa the stress exponent, n, is about 1; n gradually increases with stress being about 10 at 525 MPa and about 100 at 660 MPa. In laboratory tests, rupture ductility correlates inversely with n; the lower n the higher the ductility. In-reactor tests support this correlation thus pressure tubes in CANDU reactors, operating at 117 MPa where n approximately 1, should have good ductility. (Auth.)

  8. Surgical management of spontaneous ruptured hepatocellular adenoma

    Directory of Open Access Journals (Sweden)

    Marcelo Augusto Fontenelle Ribeiro Junior

    2009-01-01

    Full Text Available AIMS: Spontaneous ruptured hepatocellular adenoma (SRHA is a rare life-threatening condition that may require surgical treatment to control hemorrhaging and also stabilize the patient. We report a series of emergency surgeries performed at our institution for this condition. METHODS: We reviewed medical records and radiology files of 28 patients (from 1989 to 2006 with a proven diagnosis of hepatocellular adenoma (HA. Three (10.7% of 28 patients had spontaneous ruptured hepatocellular adenoma, two of which were associated with intrahepatic hemorrhage while one had intraperitoneal bleeding. Two patients were female and one was male. Both female patients had a background history of oral contraceptive use. Sudden abdominal pain associated with hemodynamic instability occurred in all patients who suffered from spontaneous ruptured hepatocellular adenoma. The mean age was 41.6 years old. The preoperative assessment included liver function tests, ultrasonography and computed tomography. RESULTS: The surgical approaches were as follows: right hemihepatectomy for controlling intraperitoneal bleeding, and right extended hepatectomy and non-anatomic resection of the liver for intrahepatic hemorrhage. There were no deaths, and the postoperative complications were bile leakage and wound infection (re-operation, as well as intraperitoneal abscess (re-operation and pleural effusion. CONCLUSION: Spontaneous ruptured hepatocellular adenoma may be treated by surgery for controlling hemorrhages and stabilizing the patient, and the decision to operate depends upon both the patient's condition and the expertise of the surgical team.

  9. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  10. Blunt traumatic diaphragmatic rupture

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Nogueira

    2011-09-01

    Full Text Available Traumatic injury of the diaphragm ranges from 0.6 to 1.2% and rise up to 5%among patients who were victims of blunt trauma and underwent laparotomy.Clinical suspicion associated with radiological assessment contributes to earlydiagnosis. Isolated diaphragmatic injury has a good prognosis. Generallyworse outcomes are associated with other trauma injuries. Bilateral andright diaphragmatic lesions have worse prognosis. Multi detector computed tomography (MDCT scan of the chest and abdomen provides better diagnosticaccuracy using the possibility of image multiplanar reconstruction. Surgicalrepair via laparotomy and/ or thoracotomy in the acute phase of the injury hasa better outcome and avoids chronic complications of diaphragmatic hernia.The authors present the case of a young male patient, victim of blunt abdominaltrauma due to motor vehicle accident with rupture of the diaphragm, spleenand kidney injuries. The diagnosis was made by computed tomography of thethorax and abdomen and was confirmed during laparotomy.

  11. Comparing slow and fast rupture in laboratory experiments

    Science.gov (United States)

    Aben, F. M.; Brantut, N.; David, E.; Mitchell, T. M.

    2017-12-01

    During the brittle failure of rock, elastically stored energy is converted into a localized fracture plane and surrounding fracture damage, seismic radiation, and thermal energy. However, the partitioning of energy might vary with the rate of elastic energy release during failure. Here, we present the results of controlled (slow) and dynamic (fast) rupture experiments on dry Lanhélin granite and Westerly granite samples, performed under triaxial stress conditions at confining pressures of 50 and 100 MPa. During the tests, we measured sample shortening, axial load and local strains (with 2 pairs of strain gauges glued directly onto the sample). In addition, acoustic emissions (AEs) and changes in seismic velocities were monitored. The AE rate was used as an indicator to manually control the axial load on the sample to stabilize rupture in the quasi-static failure experiments. For the dynamic rupture experiments a constant strain rate of 10-5 s-1 was applied until sample failure. A third experiment, labeled semi-controlled rupture, involved controlled rupture up to a point where the rupture became unstable and the remaining elastic energy was released dynamically. All experiments were concluded after a macroscopic fracture had developed across the whole sample and frictional sliding commenced. Post-mortem samples were epoxied, cut and polished to reveal the macroscopic fracture and the surrounding damage zone. The samples failed with average rupture velocities varying from 5x10-6 m/s up to >> 0.1 m/s. The analyses of AE locations on the slow ruptures reveal that within Westerly granite samples - with a smaller grain size - fracture planes are disbanded in favor of other planes when a geometrical irregularity is encountered. For the coarser grained Lanhélin granite a single fracture plane is always formed, although irregularities are recognized as well. The semi-controlled experiments show that for both rock types the rupture can become unstable in response to these

  12. Consistent creep and rupture properties for creep-fatigue evaluation

    International Nuclear Information System (INIS)

    Schultz, C.C.

    1978-01-01

    The currently accepted practice of using inconsistent representations of creep and rupture behaviors in the prediction of creep-fatigue life is shown to introduce a factor of safety beyond that specified in current ASME Code design rules for 304 stainless steel Class 1 nuclear components. Accurate predictions of creep-fatigue life for uniaxial tests on a given heat of material are obtained by using creep and rupture properties for that same heat of material. The use of a consistent representation of creep and rupture properties for a mininum strength heat is also shown to provide adequate predictions. The viability of using consistent properties (either actual or those of a minimum heat) to predict creep-fatigue life thus identifies significant design uses for the results of characterization tests and improved creep and rupture correlations

  13. Consistent creep and rupture properties for creep-fatigue evaluation

    International Nuclear Information System (INIS)

    Schultz, C.C.

    1979-01-01

    The currently accepted practice of using inconsistent representations of creep and rupture behaviors in the prediction of creep-fatigue life is shown to introduce a factor of safety beyond that specified in current ASME Code design rules for 304 stainless steel Class 1 nuclear components. Accurate predictions of creep-fatigue life for uniaxial tests on a given heat of material are obtained by using creep and rupture properties for that same heat of material. The use of a consistent representation of creep and rupture properties for a minimum strength heat is also shown to provide reasonable predictions. The viability of using consistent properties (either actual or those of a minimum strength heat) to predict creep-fatigue life thus identifies significant design uses for the results of characterization tests and improved creep and rupture correlations. 12 refs

  14. A support-operator method for 3-D rupture dynamics

    Science.gov (United States)

    Ely, Geoffrey P.; Day, Steven M.; Minster, Jean-Bernard

    2009-06-01

    We present a numerical method to simulate spontaneous shear crack propagation within a heterogeneous, 3-D, viscoelastic medium. Wave motions are computed on a logically rectangular hexahedral mesh, using the generalized finite-difference method of Support Operators (SOM). This approach enables modelling of non-planar surfaces and non-planar fault ruptures. Our implementation, the Support Operator Rupture Dynamics (SORD) code, is highly scalable, enabling large-scale, multiprocessors calculations. The fault surface is modelled by coupled double nodes, where rupture occurs as dictated by the local stress conditions and a frictional failure law. The method successfully performs test problems developed for the Southern California Earthquake Center (SCEC)/U.S. Geological Survey (USGS) dynamic earthquake rupture code validation exercise, showing good agreement with semi-analytical boundary integral method results. We undertake further dynamic rupture tests to quantify numerical errors introduced by shear deformations to the hexahedral mesh. We generate a family of meshes distorted by simple shearing, in the along-strike direction, up to a maximum of 73°. For SCEC/USGS validation problem number 3, grid-induced errors increase with mesh shear angle, with the logarithm of error approximately proportional to angle over the range tested. At 73°, rms misfits are about 10 per cent for peak slip rate, and 0.5 per cent for both rupture time and total slip, indicating that the method (which, up to now, we have applied mainly to near-vertical strike-slip faulting) is also capable of handling geometries appropriate to low-angle surface-rupturing thrust earthquakes. Additionally, we demonstrate non-planar rupture effects, by modifying the test geometry to include, respectively, cylindrical curvature and sharp kinks.

  15. Presence of Bacteria in Spontaneous Achilles Tendon Ruptures.

    Science.gov (United States)

    Rolf, Christer G; Fu, Sai-Chuen; Hopkins, Chelsea; Luan, Ju; Ip, Margaret; Yung, Shu-Hang; Friman, Göran; Qin, Ling; Chan, Kai-Ming

    2017-07-01

    The structural pathology of Achilles tendon (AT) ruptures resembles tendinopathy, but the causes remain unknown. Recently, a number of diseases were found to be attributed to bacterial infections, resulting in low-grade inflammation and progressive matrix disturbance. The authors speculate that spontaneous AT ruptures may also be influenced by the presence of bacteria. Bacteria are present in ruptured ATs but not in healthy tendons. Cross-sectional study; Level of evidence, 3. Patients with spontaneous AT ruptures and patients undergoing anterior cruciate ligament (ACL) reconstruction were recruited for this study. During AT surgical repair, excised tendinopathic tissue was collected, and healthy tendon samples were obtained as controls from hamstring tendon grafts used in ACL reconstruction. Half of every sample was reserved for DNA extraction and the other half for histology. Polymerase chain reaction (PCR) was conducted using 16S rRNA gene universal primers, and the PCR products were sequenced for the identification of bacterial species. A histological examination was performed to compare tendinopathic changes in the case and control samples. Five of 20 AT rupture samples were positive for the presence of bacterial DNA, while none of the 23 hamstring tendon samples were positive. Sterile operating and experimental conditions and tests on samples, controlling for harvesting and processing procedures, ruled out the chance of postoperative bacterial contamination. The species identified predominantly belonged to the Staphylococcus genus. AT rupture samples exhibited histopathological features characteristic of tendinopathy, and most healthy hamstring tendon samples displayed normal tendon features. There were no apparent differences in histopathology between the bacterial DNA-positive and bacterial DNA-negative AT rupture samples. The authors have demonstrated the presence of bacterial DNA in ruptured AT samples. It may suggest the potential involvement of bacteria

  16. Analysis of localized damage in creep rupture

    International Nuclear Information System (INIS)

    Wang Zhengdong; Wu Dongdi

    1992-01-01

    Continuum Damage Mechanics studies the effect of distributed defects, whereas the failure of engineering structures is usually caused by local damage. In this paper, an analysis of localized damage in creep rupture is carried out. The material tested is a 2 1/4Cr-1Mo pressure vessel steel and the material constants necessary for damage analysis are evaluated. Notched specimens are used to reflect localized damage in creep rupture and the amount of damage is measured using DCPD method. Through FEM computation, stress components and effective stress in the region of notch root are evaluated and it is found that the von Mises effective stress can represent the damage effective stress in the analysis of localized creep damage. It is possible to develop a method for the assessment of safety of pressure vessels under creep through localized creep damage analysis. (orig.)

  17. Creep rupture behavior of Stirling engine materials

    Science.gov (United States)

    Titran, R. H.; Scheuerman, C. M.; Stephens, J. R.

    1985-01-01

    The automotive Stirling engine, being investigated jointly by the Department of Energy and NASA Lewis as an alternate to the internal combustion engine, uses high-pressure hydrogen as the working fluid. The long-term effects of hydrogen on the high temperature strength properties of materials is relatively unknown. This is especially true for the newly developed low-cost iron base alloy NASAUT 4G-A1. This iron-base alloy when tested in air has creep-rupture strengths in the directionally solidified condition comparable to the cobalt base alloy HS-31. The equiaxed (investment cast) NASAUT 4G-A1 has superior creep-rupture to the equiaxed iron-base alloy XF-818 both in air and 15 MPa hydrogen.

  18. Fatigue and rupture codified rules comparison

    International Nuclear Information System (INIS)

    Faidy, C.

    2004-01-01

    The European Directive on Pressure Equipment requests risk studies and in particular to assure no risk of fatigue and rupture in operation. The answers to these questions are different in the different existing design codes (EN Standards, ASME III and VIII or RCC-M or CODAP-CODETI codes) and corresponding in operation codes (ASME or RSE-M). Design safety factors, material properties, fabrication, refinement in the analysis methods, monitoring in operation, hydro-proof test level... Around these Codes, different rules are under development. A16 in France, R6 in UK or FITNET at the EC level. This paper is concerned by a comparison between 2 different Codes to analyze the risk of fatigue or rupture of pressure equipments and mainly a comparison between RCC-M Code and EN 13445 standard for pressure vessel. Recommendations for future work will be proposed. (authors)

  19. Influence of steam generator tube ruptures during semiscale loss-of-coolant experiments

    International Nuclear Information System (INIS)

    Cozzuol, J.M.; Larson, T.K.

    1978-01-01

    Tests which simulated rupture of steam generator tubes during loss-of-coolant experiments in a PWR type system have been conducted in the Semiscale Mod-1 system. Analysis of test data indicates that high rod cladding temperatures occured only for a band of tube ruptures (between 12 and 20 tubes) and that the peak cladding temperatures attained within this band were strongly dependent on the magnitude of the tube rupture flow rates. Maximum cladding temperature of about 1255 K was observed for tests which simulated tube ruptures within this narrow band. (author)

  20. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  1. The stress rupture properties of austenitic steel weld metals

    International Nuclear Information System (INIS)

    Wood, D.S.

    Elevated temperature stress rupture data on Mo containing and Mo free austenitic weld metals have been collected from French, Dutch, German and UK sources and the results analysed. The stress rupture strength of Mo containing weld metal is significantly higher than that of Mo free weld metal. At 10,000h the rupture strength of Mo containing weld metal is higher than that of Type 316 steel whereas the Mo free weld metal is about 20% lower than that of Type 304 steel. Austenitic weld metal can give low stress rupture ductility values. It is concluded that there are insufficient data to permit reliable extrapolations to long times and it is recommended that long term tests are performed to overcome this situation

  2. Indigenous development of rupture discs for FBTR (Paper No. 028)

    International Nuclear Information System (INIS)

    Chetal, S.C.; Raju, Chander; Anandkumar, V.; Seetharaman, V.

    1987-02-01

    Rupture discs are required as a safety device for protecting the secondary sodium circuit and its components against high pressure surges due to accidental water-steam leaks in sodium heated steam generator and the consequent sodium water reaction. For identical reasons, rupture discs are also required on the vessels used for decontamination of sodium components. As an import substitution of the costly items for the FBTR Project, development of the rupture disc assemblies has been in progress at Indira Gandhi Centre for Atomic Research, Kalpakkam. Reverse buckling knife blade concept with stainless steel disc has been taken up for development. Hydroforming process without any die has been selected for disc fabrication. One rupture disc assembly required for steam generator has been tested in sodium satisfactorily. (author). 4 tables, 5 figs

  3. The diagnosis of breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse; Conrad, Carsten

    2005-01-01

    participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture...... were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89...

  4. Physics of Earthquake Rupture Propagation

    Science.gov (United States)

    Xu, Shiqing; Fukuyama, Eiichi; Sagy, Amir; Doan, Mai-Linh

    2018-05-01

    A comprehensive understanding of earthquake rupture propagation requires the study of not only the sudden release of elastic strain energy during co-seismic slip, but also of other processes that operate at a variety of spatiotemporal scales. For example, the accumulation of the elastic strain energy usually takes decades to hundreds of years, and rupture propagation and termination modify the bulk properties of the surrounding medium that can influence the behavior of future earthquakes. To share recent findings in the multiscale investigation of earthquake rupture propagation, we held a session entitled "Physics of Earthquake Rupture Propagation" during the 2016 American Geophysical Union (AGU) Fall Meeting in San Francisco. The session included 46 poster and 32 oral presentations, reporting observations of natural earthquakes, numerical and experimental simulations of earthquake ruptures, and studies of earthquake fault friction. These presentations and discussions during and after the session suggested a need to document more formally the research findings, particularly new observations and views different from conventional ones, complexities in fault zone properties and loading conditions, the diversity of fault slip modes and their interactions, the evaluation of observational and model uncertainties, and comparison between empirical and physics-based models. Therefore, we organize this Special Issue (SI) of Tectonophysics under the same title as our AGU session, hoping to inspire future investigations. Eighteen articles (marked with "this issue") are included in this SI and grouped into the following six categories.

  5. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    International Nuclear Information System (INIS)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T.

    1998-01-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  6. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T. [Valtion Teknillinen Tutkimuskeskus, Espoo (Finland)

    1998-11-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  7. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  8. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  9. Spontaneous rupture of vaginal enterocele

    DEFF Research Database (Denmark)

    Svendsen, J H; Galatius, H; Hansen, P K

    1985-01-01

    Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission.......Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission....

  10. Rupture luminescence from natural fibers

    Science.gov (United States)

    Li, W.; Haneman, D.

    1999-12-01

    Fibers of cotton and wool, and samples of paper, have been ruptured in tension in vacuum and in air, and give detectable luminescence in the visible range. All have a common emission peak at around 2.0 eV, which is ascribed to the deexcitation of states excited by the rupture of organic chain molecule bonds. Rubber bands give stronger emission in air, but no emission in vacuum, suggesting the material breaks only at weak interchain bonds. Mohair, cat, and horse hair also give emission in air. The phenomena reveal effects that would occur widely in nature.

  11. Analysis of 30 breast implant rupture cases.

    Science.gov (United States)

    Tark, Kwan Chul; Jeong, Hii Sun; Roh, Tae Suk; Choi, Jong Woo

    2005-01-01

    Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat

  12. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  13. Composite Overwrap Pressure Vessels: Mechanics and Stress Rupture Lifting Philosophy

    Science.gov (United States)

    Thesken, John C.; Murthy, Pappu L. N.; Phoenix, S. L.

    2009-01-01

    The NASA Engineering and Safety Center (NESC) has been conducting an independent technical assessment to address safety concerns related to the known stress rupture failure mode of filament wound pressure vessels in use on Shuttle and the International Space Station. The Shuttle s Kevlar-49 (DuPont) fiber overwrapped tanks are of particular concern due to their long usage and the poorly understood stress rupture process in Kevlar-49 filaments. Existing long term data show that the rupture process is a function of stress, temperature and time. However due to the presence of load sharing liners and the complex manufacturing procedures, the state of actual fiber stress in flight hardware and test articles is not clearly known. Indeed nonconservative life predictions have been made where stress rupture data and lifing procedures have ignored the contribution of the liner in favor of applied pressure as the controlling load parameter. With the aid of analytical and finite element results, this paper examines the fundamental mechanical response of composite overwrapped pressure vessels including the influence of elastic plastic liners and degraded/creeping overwrap properties. Graphical methods are presented describing the non-linear relationship of applied pressure to Kevlar-49 fiber stress/strain during manufacturing, operations and burst loadings. These are applied to experimental measurements made on a variety of vessel systems to demonstrate the correct calibration of fiber stress as a function of pressure. Applying this analysis to the actual qualification burst data for Shuttle flight hardware revealed that the nominal fiber stress at burst was in some cases 23 percent lower than what had previously been used to predict stress rupture life. These results motivate a detailed discussion of the appropriate stress rupture lifing philosophy for COPVs including the correct transference of stress rupture life data between dissimilar vessels and test articles.

  14. Composite Overwrap Pressure Vessels: Mechanics and Stress Rupture Lifing Philosophy

    Science.gov (United States)

    Thesken, John C.; Murthy, Pappu L. N.; Phoenix, Leigh

    2007-01-01

    The NASA Engineering and Safety Center (NESC) has been conducting an independent technical assessment to address safety concerns related to the known stress rupture failure mode of filament wound pressure vessels in use on Shuttle and the International Space Station. The Shuttle's Kevlar-49 fiber overwrapped tanks are of particular concern due to their long usage and the poorly understood stress rupture process in Kevlar-49 filaments. Existing long term data show that the rupture process is a function of stress, temperature and time. However due to the presence of load sharing liners and the complex manufacturing procedures, the state of actual fiber stress in flight hardware and test articles is not clearly known. Indeed non-conservative life predictions have been made where stress rupture data and lifing procedures have ignored the contribution of the liner in favor of applied pressure as the controlling load parameter. With the aid of analytical and finite element results, this paper examines the fundamental mechanical response of composite overwrapped pressure vessels including the influence of elastic-plastic liners and degraded/creeping overwrap properties. Graphical methods are presented describing the non-linear relationship of applied pressure to Kevlar-49 fiber stress/strain during manufacturing, operations and burst loadings. These are applied to experimental measurements made on a variety of vessel systems to demonstrate the correct calibration of fiber stress as a function of pressure. Applying this analysis to the actual qualification burst data for Shuttle flight hardware revealed that the nominal fiber stress at burst was in some cases 23% lower than what had previously been used to predict stress rupture life. These results motivate a detailed discussion of the appropriate stress rupture lifing philosophy for COPVs including the correct transference of stress rupture life data between dissimilar vessels and test articles.

  15. PREMATURE RUPTURE OF THE MEMBRANES*

    African Journals Online (AJOL)

    In patients presenting with premature rupture of the membranes there are two factors which influence the foetal morbidity and mortality. These factors are prema- turity and intra-uterine infection. The purpose of this analysis was to elucidate which factor carried the greater risk to the foetus. Recently there has been a spate of.

  16. Ruptured Cervical Anellrysm with Neurofibromatosis

    African Journals Online (AJOL)

    rupture of an aneurysm of a lateral branch of the right thyrocervical trunk in a patient suffering from diffuse neurofibromatosis. The operative findings are reported. s. Air. Med. ... system demonstrated decreased power in all muscles of the right shoulder girdle and arm, without sensory change. The cranial nerves were normal.

  17. Spontaneous Splenic Rupture in Melanoma

    Directory of Open Access Journals (Sweden)

    Hadi Mirfazaelian

    2014-01-01

    Full Text Available Spontaneous rupture of spleen due to malignant melanoma is a rare situation, with only a few case reports in the literature. This study reports a previously healthy, 30-year-old man who came with chief complaint of acute abdominal pain to emergency room. On physical examination, abdominal tenderness and guarding were detected to be coincident with hypotension. Ultrasonography revealed mild splenomegaly with moderate free fluid in abdominopelvic cavity. Considering acute abdominal pain and hemodynamic instability, he underwent splenectomy with splenic rupture as the source of bleeding. Histologic examination showed diffuse infiltration by tumor. Immunohistochemical study (positive for S100, HMB45, and vimentin and negative for CK, CD10, CK20, CK7, CD30, LCA, EMA, and chromogranin confirmed metastatic malignant melanoma. On further questioning, there was a past history of a nasal dark skin lesion which was removed two years ago with no pathologic examination. Spontaneous (nontraumatic rupture of spleen is an uncommon situation and it happens very rarely due to neoplastic metastasis. Metastasis of malignant melanoma is one of the rare causes of the spontaneous rupture of spleen.

  18. Vortex dynamics in ruptured and unruptured intracranial aneurysms

    Science.gov (United States)

    Trylesinski, Gabriel

    Intracranial aneurysms (IAs) are a potentially devastating pathological dilation of brain arteries that affect 1.5-5 % of the population. Causing around 500 000 deaths per year worldwide, their detection and treatment to prevent rupture is critical. Multiple recent studies have tried to find a hemodynamics predictor of aneurysm rupture, but concluded with distinct opposite trends using Wall Shear Stress (WSS) based parameters in different clinical datasets. Nevertheless, several research groups tend to converge for now on the fact that the flow patterns and flow dynamics of the ruptured aneurysms are complex and unstable. Following this idea, we investigated the vortex properties of both unruptured and ruptured cerebral aneurysms. A brief comparison of two Eulerian vortex visualization methods (Q-criterion and lambda 2 method) showed that these approaches gave similar results in our complex aneurysm geometries. We were then able to apply either one of them to a large dataset of 74 patient specific cases of intracranial aneurysms. Those real cases were obtained by 3D angiography, numerical reconstruction of the geometry, and then pulsatile CFD simulation before post-processing with the mentioned vortex visualization tools. First we tested the two Eulerian methods on a few cases to verify their implementation we made as well as compare them with each other. After that, the Q-criterion was selected as method of choice for its more obvious physical meaning (it shows the balance between two characteristics of the flow, its swirling and deformation). Using iso-surfaces of Q, we started by categorizing the patient-specific aneurysms based on the gross topology of the aneurysmal vortices. This approach being unfruitful, we found a new vortex-based characteristic property of ruptured aneurysms to stratify the rupture risk of IAs that we called the Wall-Kissing Vortices, or WKV. We observed that most ruptured aneurysms had a large amount of WKV, which appears to agree with

  19. Endometriosis-related spontaneous diaphragmatic rupture.

    Science.gov (United States)

    Triponez, Frédéric; Alifano, Marco; Bobbio, Antonio; Regnard, Jean-François

    2010-10-01

    Non-traumatic, spontaneous diaphragmatic rupture is a rare event whose pathophysiology is not known. We report the case of endometriosis-related spontaneous rupture of the right diaphragm with intrathoracic herniation of the liver, gallbladder and colon. We hypothesize that the invasiveness of endometriotic tissue caused diaphragm fragility, which finally lead to its complete rupture without traumatic event. The treatment consisted of a classical management of diaphragmatic rupture, with excision of the endometriotic nodule followed by medical ovarian suppression for six months.

  20. ACL Rupture in Collegiate Wrestler

    Directory of Open Access Journals (Sweden)

    Lindsay A. Palmer

    2016-05-01

    Full Text Available Objective: To educate others on unique Anterior Cruciate Ligament tears and percentage of usage of the ACL in normal daily function. Background: Patient is an eighteen year old male participating in wrestling and football at the time of the injury. Patient now only participates in wrestling. No previous knee or chronic injuries were reported prior to this injury. Patient was playing football during the time of injury. The patient stated that he planted his foot down and was tackled at the same time when the injury occurred. The patient felt his knee twist and buckle. Patient complained of clicking inside the knee and had minimal swelling. He also complained of it being difficult to bear weight at the time. The patient did not seek further treatment until two months after the injury occurred when he received an MRI. His MRI showed a positive finding for an Anterior Cruciate Ligament rupture. His previous Athletic Trainer could not find a positive diagnosis for the patient prior to the MRI. Differential Diagnosis: Possible meniscal or ACL injury. Treatment: Doctors officially diagnosed the injury as a complete rupture of the ACL. The patient did not receive surgery immediately. Doctors have stated that he only uses about 50% of his ACL on a daily basis compared to a normal person who uses about 95% of their ACL daily. Because of this, the patient played on his rupture for seven months before receiving surgery. He played a whole season of high school football and a whole season of wrestling his senior year with the ACL ruptured. The patient only used a brace for better comfort during the seven months. The patient then received reconstructive surgery to repair the rupture. A hamstring tendon graft was used to repair the ruptured ACL. Because a tendon was taken from the hamstring, patient experienced a tight ACL and hamstring of the left leg post-surgery. The patient participated in Physical Therapy for five months to strengthen and stretch the new

  1. Possibilities for power reactor structural material and fuel testing in reactor RA; Mogucnosti reaktora RA za testiranje konstrukcionih materijala i goriva energetskih reaktora

    Energy Technology Data Exchange (ETDEWEB)

    Martinc, R; Lazarevic, Dj; Stefanovic, D; Cupac, S; Pesic, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1978-05-15

    Nuclear reactor RA at Vinca has been designed as a high flux general purpose research reactor. Among other it was intended to play a role of material testing reactor. A scope of activities of Material Laboratory and Reactor RA Department of Boris Kidric Institute is presented in this report. Reactor RA capacity for reactor structural material and fuel irradiation is also described. The increase of RA reactor irradiation capacity is based on the improvement of VISA type fuel channel for fast neutron irradiations, as well as on the general neutron flux increase, due to introduction of highly enriched uranium fuel into reactor core and the advanced in-core fuel management. The irradiation capacities described allow for the reactor material and fuel testing to the considerable extent. Istrazivacki reaktor RA u Vinci je projektovan kao visokofluksni istrazivacki reaktor opste namene. Pored ostalog, on je namenjen i za testiranje reaktorskih konstrukcionih materijala i goriva. U radu je dat pregled aktivnosti Laboratorije za materijale IBK i reaktora RA na tom podrucju, kao i opis povecanih mogucnosti reaktora RA za ozracivanje reaktorskih materijala i goriva u cilju njihovog testiranja. Povecanje mogucnosti reaktora RA zasniva se na usavrsavanju specijalnog gorivnog kanala tipa VISA (za ozracivanje materijala brzim neutronima), kao i na opstem povecanju neutronskog fluksa na osnovu uvodjenja i nacina koriscenja visokoobogacenog uranskog goriva u reaktoru RA. Opisane mogucnosti reaktora RA dozvoljavaju u znatnoj meri ispitivanje konstrukcionih materijala i goriva energetskih reaktora.

  2. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  3. Improvement in the technology of thermocouples for the detection of high temperatures with a view to using them in irradiation safety tests in reactor

    International Nuclear Information System (INIS)

    Schley, R.; Liermann, J.; Aujollet, J.M.; Wilkins, S.C.

    1979-01-01

    The safety tests carried out under the CABRI and PHEBUS programmes have made it possible to improve the technology of W/Re thermocouples and their reliability in particularly hard operating conditions. An element of response is provided to the problem of W/Re thermocouple drift under neutron flux by defining the new thermocouple Mo 5% Nb/Nb 10% Mo which, because of the low capture cross section of thermoelectric elements, gives one reason to hope for a less significant drift of these thermocouples under neutron flux than that found with W/Re thermocouples. Finally, determining the surface temperature of fuel element cladding with the Mo/Zircaloy thermocouple may prove worthwhile providing the temperatures do not exceed 1300 0 C and the electric insulator is aluminium oxide which up to 1300 0 C does not appear to react with thermoelectric wires [fr

  4. Rupture of the atherosclerotic plaque: does a good animal model exist?

    NARCIS (Netherlands)

    Cullen, Paul; Baetta, Roberta; Bellosta, Stefano; Bernini, Franco; Chinetti, Giulia; Cignarella, Andrea; von Eckardstein, Arnold; Exley, Andrew; Goddard, Martin; Hofker, Marten; Hurt-Camejo, Eva; Kanters, Edwin; Kovanen, Petri; Lorkowski, Stefan; McPheat, William; Pentikäinen, Markku; Rauterberg, Jürgen; Ritchie, Andrew; Staels, Bart; Weitkamp, Benedikt; de Winther, Menno

    2003-01-01

    By its very nature, rupture of the atherosclerotic plaque is difficult to study directly in humans. A good animal model would help us not only to understand how rupture occurs but also to design and test treatments to prevent it from happening. However, several difficulties surround existing models

  5. New considerations on variability of creep rupture data and life prediction

    International Nuclear Information System (INIS)

    Kim, Seon Jin; Jeong, Won Taek; Kong, Yu Sik

    2009-01-01

    This paper deals with the variability analysis of short term creep rupture test data based on the previous creep rupture tests and the possibility of the creep life prediction. From creep tests performed by constant uniaxial stresses at 600, 650 and 700 .deg. C elevated temperature, in order to investigate the variability of short-term creep rupture data, the creep curves were analyzed for normalized creep strain divided by initial strain. There are some variability in thee creep rupture data. And, the difference between general creep curves and normalized creep curves were obtained. The effects of the creep rupture time and state steady creep rate on the Weibull distribution parameters were investigated. There were good relation between normal Weibull parameters and normalized Weibull parameters. Finally, the predicted creep life were compared with the Monkman-Grant model.

  6. New Considerations on Variability of Creep Rupture Data and Life Prediction

    International Nuclear Information System (INIS)

    Jung, Won Taek; Kong, Yu Sik; Kim, Seon Jin

    2009-01-01

    This paper deals with the variability analysis of short term creep rupture test data based on the previous creep rupture tests and the possibility of the creep life prediction. From creep tests performed by constant uniaxial stresses at 600, 650 and 700 .deg. C elevated temperature, in order to investigate the variability of short-term creep rupture data, the creep curves were analyzed for normalized creep strain divided by initial strain. There are some variability in the creep rupture data. And, the difference between general creep curves and normalized creep curves were obtained. The effects of the creep rupture time (RT) and steady state creep rate (SSCR) on the Weibull distribution parameters were investigated. There were good relation between normal Weibull parameters and normalized Weibull parameters. Finally, the predicted creep life were compared with the Monkman-Grant model

  7. Energia total de ruptura: um teste biomecânico para avaliação de material biológico com propriedade viscoelástica não linear Total energy of rupture: a biomechanical test to evaluate non-linear viscoelastic biological material

    Directory of Open Access Journals (Sweden)

    Feng Chung Wu

    2004-12-01

    Full Text Available Objetivo: Apresentação do teste biomecânico Energia Total de Ruptura para o estudo da resistência intrínseca de material biológico com propriedade viscoelástica não-linear representado neste trabalho por segmento íntegro de cólon descendente de rato. Métodos: Implementação do teste biomecânico Energia Total de Ruptura e do Sistema de Aquisição e Análise de dados Biomecânicos - SABI 2.0. Para esse fim, foram utilizados conceitos físico-mecânicos, computacionais e biomecânicos e como corpos de teste, 15 espécimes de cólon descendente de ratos. Resultados: O teste biomecânico Energia Total de Ruptura permitiu o cálculo da energia total acumulada necessária para promover a ruptura dos corpos de prova durante os ensaios mecânicos. Por meio da automatização e gerenciamento da aquisição e análise dos dados capturados foi possível a geração de gráficos e relatórios descritivos e estatísticos. Conclusão: Fundamentado em conceitos físico-mecânicos, computacionais e biomecânicos, o teste Energia Total de Ruptura pôde proporcionar análise matemática do comportamento dos segmentos de cólon descendente de ratos durante os ensaios, demonstrando ser um possível método de medição da resistência intrínseca desse material biológico com propriedade viscoelástica não-linear.Purpose: Presentation of the Total Energy of Rupture biomechanical test to evaluate the intrinsic resistance of the rat’s left colon which presents a non-linear viscoelastic property. Methods: Implementation of Total Energy of Rupture test (ETR and the Biomechanical Data Acquisition and Analysis System (SABI 2.0 based on physic-mechanical, computational and biomechanical concepts. Fifteen specimens of Wistar adults rat’s left colon where considered for experiments. Results: Using the TER biomechanical test it was possible calculate the accumulated total energy necessary to promote the specimens rupture during the mechanical trial. It was

  8. Study on human-factors-engineering properties of reactor maintenance workers with protection suits, (2). Basic research on various biological characteristics in reactor maintenance simulation tests

    Energy Technology Data Exchange (ETDEWEB)

    Yoshino, K; Ishii, K; Nakasa, H [Central Research Inst. of Electric Power Industry, Tokyo (Japan); Shigeta, S

    1980-11-01

    To ensure the safety of reactor maintenance workers and to reduce the radiation exposure through the enhancement of labor efficiency, it is needed to evaluate quantitatively work-stress levels of workers with radiation-protection suits. This paper presents the results of reactor-maintenance simulation tests in which the relationship between the work stress and biological characteristics is investigated for 5 pinds of model works done by testees without protection suits in an artificial climate chamber. Major results obtained are: (1) the selected model works are mostly evaluated to be relatively heavy through the measurement of RMR (Relative Metabolic Rate). (2) biological characteristics such as heart rate and respiratory volume under the model works have close relationship to RMR which is the cumulative quantity in relatively long time, and then they may become the real-time indicator for the work stress level. (3) such biological characteristics are greatly affected by the high-temperature work-environment which is often seen in workers with protection suits.

  9. Spontaneous Extensor Tendon Rupture in the Rheumatoid Wrist: Risk Factors and Preventive Role of Extended Tenosynovectomy.

    Science.gov (United States)

    Hsueh, Jung-Hua; Liu, Wen-Chung; Yang, Kuo-Chung; Hsu, Kuei-Chang; Lin, Cheng-Ta; Chen, Lee-Wei

    2016-03-01

    Spontaneous extensor tendon rupture is often seen in rheumatoid arthritis (RA) patients, but the risk factors are not clearly defined. We therefore collected the data of RA patients with previous extensor tendon rupture and those with tenosynovitis and analyzed the relationship between extended tenosynovectomy and spontaneous extensor tendon rupture. We retrospectively reviewed 17 spontaneous extensor tendon rupture episodes in 15 RA patients and 14 tenosynovitis episodes that required tenosynovectomy in 12 RA patients from 1997 to 2013. Correlations between the incidence of tendon rupture, X-ray findings, and clinical findings in the affected wrists before tendon rupture were analyzed statistically using the test for proportion. The following parameters were significantly correlated with spontaneous extensor tendon rupture: disease duration longer than 8 years, persistent tenosynovitis longer than 1 year duration, and Larsen grade greater than 4 (P = 0.02, 0.03, and 0.01, respectively). Dislocation of the distal end of the ulna, carpal collapse, and the scallop sign on X-ray contributed to a higher spontaneous extensor tendon rupture rate among RA patients (P = 0.01, 0.05, and 0.03, respectively). Extended tenosynovectomy was performed on 14 wrists in 12 RA patients with persistent tenosynovitis longer than 6 months, and Larsen grade did not deteriorate in this group compared with those who did not undergo the surgery. No spontaneous extensor tendon rupture occurred following the surgery. Risk factors of spontaneous extensor tendon rupture included disease duration longer than 8 years, persistent tenosynovitis longer than 1 year, and wrist Larsen grade greater than 4. Dislocation of the distal end of the ulna, carpal collapse, and the scallop sign on X-ray indicated a higher probability of extensor tendon rupture. Rheumatologists should consult with hand surgeons promptly to preserve hand function before tendon rupture. Prophylactic extended tenosynovectomy

  10. Babcock and Wilcox model for predicting in-reactor densification

    International Nuclear Information System (INIS)

    Buescher, B.J.; Pegram, J.W.

    1977-07-01

    The B and W densification model is based on a correlation between in-reactor densification and a thermal resintering test. The densification model has been found to predict in-reactor densification with a remarkable degree of accuracy for fuel pellets operated at heat rates above 5 kW/ft and with considerable conservatism for pellelts operating at heat rates below 5 kW/ft

  11. Characterize kinematic rupture history of large earthquakes with Multiple Haskell sources

    Science.gov (United States)

    Jia, Z.; Zhan, Z.

    2017-12-01

    Earthquakes are often regarded as continuous rupture along a single fault, but the occurrence of complex large events involving multiple faults and dynamic triggering challenges this view. Such rupture complexities cause difficulties in existing finite fault inversion algorithms, because they rely on specific parameterizations and regularizations to obtain physically meaningful solutions. Furthermore, it is difficult to assess reliability and uncertainty of obtained rupture models. Here we develop a Multi-Haskell Source (MHS) method to estimate rupture process of large earthquakes as a series of sub-events of varying location, timing and directivity. Each sub-event is characterized by a Haskell rupture model with uniform dislocation and constant unilateral rupture velocity. This flexible yet simple source parameterization allows us to constrain first-order rupture complexity of large earthquakes robustly. Additionally, relatively few parameters in the inverse problem yields improved uncertainty analysis based on Markov chain Monte Carlo sampling in a Bayesian framework. Synthetic tests and application of MHS method on real earthquakes show that our method can capture major features of large earthquake rupture process, and provide information for more detailed rupture history analysis.

  12. Morphology parameters for intracranial aneurysm rupture risk assessment.

    Science.gov (United States)

    Dhar, Sujan; Tremmel, Markus; Mocco, J; Kim, Minsuok; Yamamoto, Junichi; Siddiqui, Adnan H; Hopkins, L Nelson; Meng, Hui

    2008-08-01

    The aim of this study is to identify image-based morphological parameters that correlate with human intracranial aneurysm (IA) rupture. For 45 patients with terminal or sidewall saccular IAs (25 unruptured, 20 ruptured), three-dimensional geometries were evaluated for a range of morphological parameters. In addition to five previously studied parameters (aspect ratio, aneurysm size, ellipticity index, nonsphericity index, and undulation index), we defined three novel parameters incorporating the parent vessel geometry (vessel angle, aneurysm [inclination] angle, and [aneurysm-to-vessel] size ratio) and explored their correlation with aneurysm rupture. Parameters were analyzed with a two-tailed independent Student's t test for significance; significant parameters (P 41; 95% confidence interval, 1.03-1.92) and undulation index (odds ratio, 1.51; 95% confidence interval, 1.08-2.11) had the strongest independent correlation with ruptured IA. From the receiver operating characteristic analysis, size ratio and aneurysm angle had the highest area under the curve values of 0.83 and 0.85, respectively. Size ratio and aneurysm angle are promising new morphological metrics for IA rupture risk assessment. Because these parameters account for vessel geometry, they may bridge the gap between morphological studies and more qualitative location-based studies.

  13. Validity and Reliability of the Achilles Tendon Total Rupture Score

    DEFF Research Database (Denmark)

    Ganestam, Ann; Barfod, Kristoffer; Klit, Jakob

    2013-01-01

    study was to validate a Danish translation of the ATRS. The ATRS was translated into Danish according to internationally adopted standards. Of 142 patients, 90 with previous rupture of the Achilles tendon participated in the validity study and 52 in the reliability study. The ATRS showed moderately......The best treatment of acute Achilles tendon rupture remains debated. Patient-reported outcome measures have become cornerstones in treatment evaluations. The Achilles tendon total rupture score (ATRS) has been developed for this purpose but requires additional validation. The purpose of the present...... = .07). The limits of agreement were ±18.53. A strong correlation was found between test and retest (intercorrelation coefficient .908); the standard error of measurement was 6.7, and the minimal detectable change was 18.5. The Danish version of the ATRS showed moderately strong criterion validity...

  14. Size ratio correlates with intracranial aneurysm rupture status: a prospective study.

    Science.gov (United States)

    Rahman, Maryam; Smietana, Janel; Hauck, Erik; Hoh, Brian; Hopkins, Nick; Siddiqui, Adnan; Levy, Elad I; Meng, Hui; Mocco, J

    2010-05-01

    The prediction of intracranial aneurysm (IA) rupture risk has generated significant controversy. The findings of the International Study of Unruptured Intracranial Aneurysms (ISUIA) that small anterior circulation aneurysms (IAs are small. These discrepancies have led to the search for better aneurysm parameters to predict rupture. We previously reported that size ratio (SR), IA size divided by parent vessel diameter, correlated strongly with IA rupture status (ruptured versus unruptured). These data were all collected retrospectively off 3-dimensional angiographic images. Therefore, we performed a blinded prospective collection and evaluation of SR data from 2-dimensional angiographic images for a consecutive series of patients with ruptured and unruptured IAs. We prospectively enrolled 40 consecutive patients presenting to a single institution with either ruptured IA or for first-time evaluation of an incidental IA. Blinded technologists acquired all measurements from 2-dimensional angiographic images. Aneurysm rupture status, location, IA maximum size, and parent vessel diameter were documented. The SR was calculated by dividing the aneurysm size (mm) by the average parent vessel size (mm). A 2-tailed Mann-Whitney test was performed to assess statistical significance between ruptured and unruptured groups. Fisher exact test was used to compare medical comorbidities between the ruptured and unruptured groups. Significant differences between the 2 groups were subsequently tested with logistic regression. SE and probability values are reported. Forty consecutive patients with 24 unruptured and 16 ruptured aneurysms met the inclusion criteria. No significant differences were found in age, gender, smoking status, or medical comorbidities between ruptured and unruptured groups. The average maximum size of the unruptured IAs (6.18 + or - 0.60 mm) was significantly smaller compared with the ruptured IAs (7.91 + or - 0.47 mm; P=0.03), and the unruptured group had

  15. Renal allograft rupture: US diagnosis

    International Nuclear Information System (INIS)

    Maklad, N.F.

    1987-01-01

    The US appearances in seven pathologically and/or surgically proved cases of renal allograft rupture are presented. These include a triangular or amorphous echogenic area in the cortex and medulla in a polar location, an echogenic band or wavy, branching anechoic lines in the hyperechoic region, a subcapsular hematoma, and an extrarenal hematoma in direct continuity with the echogenic area. Duplex Doppler examination in renal allograft rupture shows marked reduction of absence of the diastolic component of the velocity waveform in the arcuate and interlobar arteries, with reduction in amplitude of the systolic wave form. Correlation of the US appearances with gross and microscopic pathologic findings indicates that the echogenic area is due to an intrarenal hematoma, while the echogenic band represents the cortical laceration with adherent blood clots. The US-duplex Doppler examination should be the primary diagnostic modality in this life-threatening condition

  16. Spontaneous liver rupture in pregnancy complicating HELLP syndrome: case report

    Directory of Open Access Journals (Sweden)

    Sariyeh Golmahammadlou

    2014-10-01

    Conclusion: Spontaneous liver rupture associated with HELLP syndrome is a rare and life-threatening complication of pregnancy. Unruptured liver hematoma is also a rare condition during pregnancy with a very difficult diagnosis. Using clinical diagnostic tests such as CT scan or MRI would be helpful to improve clinical outcomes.

  17. Rupture Loop Annex (RLA) ion exchange vault entry and characterization

    International Nuclear Information System (INIS)

    Ham, J.E.

    1996-01-01

    This engineering report documents the entry and characterization of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located near the 309 Building's Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns were found in the vault. Some of which contained transuranics, Cs 137, and Co 60. The characterization information is necessary for future vault cleanout and column disposal

  18. Achilles tendon rupture in badminton.

    Science.gov (United States)

    Kaalund, S; Lass, P; Høgsaa, B; Nøhr, M

    1989-01-01

    The typical badminton player with an Achilles tendon rupture is 36 years old and, despite limbering up, is injured at the rear line in a sudden forward movement. He resumes work within three months and has a slight lack of dorsiflexion in the ankle as the main complication. Most patients resume badminton within one year, but some finish their sports career, mainly due to fear of a new injury. The investigation discusses predisposing factors and prophylactic measures. PMID:2605439

  19. Investigation on Stress-Rupture Behavior of a Chopped-Glass-Fiber Composite for Automotive Durability Design Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Ren, W

    2001-08-24

    Practical and inexpensive testing methods were developed to investigate stress-rupture properties of a polymeric composite with chopped glass fiber reinforcement for automotive applications. The material was tested in representative automotive environments to generate experimental data. The results indicate that environments have substantial effects on the stress-rupture behavior. The data were analyzed and developed into stress-rupture design criteria to address one of the durability aspects of the material for automotive structural applications.

  20. Investigation on Stress-Rupture Behavior of a Chopped-Glass-Fiber Composite for Automotive Durability Design Criteria; FINAL

    International Nuclear Information System (INIS)

    Ren, W

    2001-01-01

    Practical and inexpensive testing methods were developed to investigate stress-rupture properties of a polymeric composite with chopped glass fiber reinforcement for automotive applications. The material was tested in representative automotive environments to generate experimental data. The results indicate that environments have substantial effects on the stress-rupture behavior. The data were analyzed and developed into stress-rupture design criteria to address one of the durability aspects of the material for automotive structural applications

  1. The Reasons of Steam Pipeline Elbow Rupture

    Directory of Open Access Journals (Sweden)

    Mesjasz A.

    2016-09-01

    Full Text Available In the paper the reasons for steam pipeline’s elbow material rupture, made of steel 13CrMo4-5 (15HM that is being used in the energetics. Based on the mechanical properties in the ambient temperature (Rm, Rp0,2 and elongation A5 and in the increased temperature (Rp0,2t it was found, that the pipeline elbow’s material sampled from the ruptured area has lower Rp0,2 i Rp0,2t by around 2% than it is a requirement for 13CrMo4-5 steel in it’s base state. The damage appeared as a result of complex stress state, that substantially exceeded the admissible tensions, what was the consequence of considerable structure degradation level. As a result of the microstructure tests on HITACHI S4200 microscope, the considerable development of the creeping process associates were found. Also the advances progress of the microstructure degradation was observed, which is substantial decomposition of bainite and multiple, with varied secretion size, and in most cases forming the micro cracks chains. With the use of lateral micro sections the creeping voids were observed, that creates at some places the shrinkage porosities clusters and micro pores.

  2. Cyclic creep-rupture behavior of three high-temperature alloys.

    Science.gov (United States)

    Halford, G. R.

    1972-01-01

    Study of some important characteristics of the cyclic creep-rupture curves for the titanium alloy 6Al-2Sn-4Zr-2Mo at 900 and 1100 F (755 and 865 K), the cobalt-base alloy L-605 at 1180 F (910 K), and for two hardness levels of 316 stainless steel at 1300 F (980 K). The cyclic creep-rupture curve relates tensile stress and tensile time-to-rupture for strain-limited cyclic loading and has been found to be independent of the total strain range and the level of compressive stress employed in the cyclic creep-rupture tests. The cyclic creep-rupture curve was always found to be above and to the right of the conventional (constant load) monotonic creep-rupture curve by factors ranging from 2 to 10 in time-to-rupture. This factor tends to be greatest when the creep ductility is large. Cyclic creep acceleration was observed in every cyclic creep-rupture test conducted. The phenomenon was most pronounced at the highest stress levels and when the tensile and compressive stresses were completely reversed. In general, creep rates were found to be lower in compression than in tension for equal true stresses. The differences, however, were strongly material-dependent.

  3. Validation of statistical models for creep rupture by parametric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, J., E-mail: john.bolton@uwclub.net [65, Fisher Ave., Rugby, Warks CV22 5HW (United Kingdom)

    2012-01-15

    Statistical analysis is an efficient method for the optimisation of any candidate mathematical model of creep rupture data, and for the comparative ranking of competing models. However, when a series of candidate models has been examined and the best of the series has been identified, there is no statistical criterion to determine whether a yet more accurate model might be devised. Hence there remains some uncertainty that the best of any series examined is sufficiently accurate to be considered reliable as a basis for extrapolation. This paper proposes that models should be validated primarily by parametric graphical comparison to rupture data and rupture gradient data. It proposes that no mathematical model should be considered reliable for extrapolation unless the visible divergence between model and data is so small as to leave no apparent scope for further reduction. This study is based on the data for a 12% Cr alloy steel used in BS PD6605:1998 to exemplify its recommended statistical analysis procedure. The models considered in this paper include a) a relatively simple model, b) the PD6605 recommended model and c) a more accurate model of somewhat greater complexity. - Highlights: Black-Right-Pointing-Pointer The paper discusses the validation of creep rupture models derived from statistical analysis. Black-Right-Pointing-Pointer It demonstrates that models can be satisfactorily validated by a visual-graphic comparison of models to data. Black-Right-Pointing-Pointer The method proposed utilises test data both as conventional rupture stress and as rupture stress gradient. Black-Right-Pointing-Pointer The approach is shown to be more reliable than a well-established and widely used method (BS PD6605).

  4. Determine Earthquake Rupture Directivity Using Taiwan TSMIP Strong Motion Waveforms

    Science.gov (United States)

    Chang, Kaiwen; Chi, Wu-Cheng; Lai, Ying-Ju; Gung, YuanCheng

    2013-04-01

    Inverting seismic waveforms for the finite fault source parameters is important for studying the physics of earthquake rupture processes. It is also significant to image seismogenic structures in urban areas. Here we analyze the finite-source process and test for the causative fault plane using the accelerograms recorded by the Taiwan Strong-Motion Instrumentation Program (TSMIP) stations. The point source parameters for the mainshock and aftershocks were first obtained by complete waveform moment tensor inversions. We then use the seismograms generated by the aftershocks as empirical Green's functions (EGFs) to retrieve the apparent source time functions (ASTFs) of near-field stations using projected Landweber deconvolution approach. The method for identifying the fault plane relies on the spatial patterns of the apparent source time function durations which depend on the angle between rupture direction and the take-off angle and azimuth of the ray. These derived duration patterns then are compared with the theoretical patterns, which are functions of the following parameters, including focal depth, epicentral distance, average crustal 1D velocity, fault plane attitude, and rupture direction on the fault plane. As a result, the ASTFs derived from EGFs can be used to infer the ruptured fault plane and the rupture direction. Finally we used part of the catalogs to study important seismogenic structures in the area near Chiayi, Taiwan, where a damaging earthquake has occurred about a century ago. The preliminary results show a strike-slip earthquake on 22 October 1999 (Mw 5.6) has ruptured unilaterally toward SSW on a sub-vertical fault. The procedure developed from this study can be applied to other strong motion waveforms recorded from other earthquakes to better understand their kinematic source parameters.

  5. Numerical modelling of Charpy-V notch test by local approach to fracture. Application to an A508 steel in the ductile-brittle transition range; Modelisation de l'essai Charpy par l'approche locale de la rupture. Application au cas de l'acier 16MND5 dans le domaine de transition

    Energy Technology Data Exchange (ETDEWEB)

    Tanguy, B

    2001-07-15

    Ferritic steels present a transition of the rupture mode which goes progressively of a brittle rupture (cleavage) to a ductile rupture when the temperature increases. The following of the difference of the transition temperature of the PWR vessel steel by the establishment of toughness curves makes of the Charpy test an integrating part of the monitoring of the French PWR reactors. In spite of the advantages which are adapted to it in particular its cost, the Charpy test does not allow to obtain directly a variable which characterizes a crack propagation resistance as for instance the toughness used for qualifying the mechanical integrity of a structure. This work deals with the establishment of the through impact strength-toughness in the transition range of the vessel steel: 16MND5 from a non-empirical approach based on the local approach of the rupture. The brittle rupture is described by the Beremin model (1983), which allows to describe the dispersion inherent in this rupture mode. The description of the brittle fissure is carried out by the GTN model (1984) and by the Rousselier model (1986). This last model has been modified in order to obtain a realistic description of the brittle damage in the case of fast solicitations and of local heating. The method proposed to determine the parameters of the damage models depends only of tests on notched specimens and of the inclusion data of the material. The behaviour is described by an original formulation parametrized in temperature which allows to describe all the tests carried out in this study. Before using this methodology, an experimental study of the behaviour and of the rupture modes of the steel 16MND5 has been carried out. From the toughness tests carried out in quasi-static and dynamical conditions, it has been revealed that this steel does not present important unwedging of its toughness curve due to the velocity effect. In the transition range, local heating of about 150 C have been measured in the root

  6. Numerical modelling of Charpy-V notch test by local approach to fracture. Application to an A508 steel in the ductile-brittle transition range; Modelisation de l'essai Charpy par l'approche locale de la rupture. Application au cas de l'acier 16MND5 dans le domaine de transition

    Energy Technology Data Exchange (ETDEWEB)

    Tanguy, B

    2001-07-15

    Ferritic steels present a transition of the rupture mode which goes progressively of a brittle rupture (cleavage) to a ductile rupture when the temperature increases. The following of the difference of the transition temperature of the PWR vessel steel by the establishment of toughness curves makes of the Charpy test an integrating part of the monitoring of the French PWR reactors. In spite of the advantages which are adapted to it in particular its cost, the Charpy test does not allow to obtain directly a variable which characterizes a crack propagation resistance as for instance the toughness used for qualifying the mechanical integrity of a structure. This work deals with the establishment of the through impact strength-toughness in the transition range of the vessel steel: 16MND5 from a non-empirical approach based on the local approach of the rupture. The brittle rupture is described by the Beremin model (1983), which allows to describe the dispersion inherent in this rupture mode. The description of the brittle fissure is carried out by the GTN model (1984) and by the Rousselier model (1986). This last model has been modified in order to obtain a realistic description of the brittle damage in the case of fast solicitations and of local heating. The method proposed to determine the parameters of the damage models depends only of tests on notched specimens and of the inclusion data of the material. The behaviour is described by an original formulation parametrized in temperature which allows to describe all the tests carried out in this study. Before using this methodology, an experimental study of the behaviour and of the rupture modes of the steel 16MND5 has been carried out. From the toughness tests carried out in quasi-static and dynamical conditions, it has been revealed that this steel does not present important unwedging of its toughness curve due to the velocity effect. In the transition range, local heating of about 150 C have been measured in the root

  7. Tensile and Creep-Rupture Evaluation of a New Heat of Haynes Alloy 25

    International Nuclear Information System (INIS)

    Shingledecker, J.P.; Glanton, D.B.; Martin, R.L.; Sparks, B.L.; Swindeman, R.W.

    2007-01-01

    From 1999 to 2006, a program was undertaken within the Materials Science and Technology Division, formerly the Metals and Ceramics Division, of Oak Ridge National Laboratory to characterize the tensile and creep-rupture properties of a newly produced heat of Haynes alloy 25 (L-605). Tensile properties from room temperature to 1100 C were evaluated for base material and welded joints aged up to 12,000 hours at 675 C. Creep and creep-rupture tests were conducted on base metal and cross-weldments from 650 to 950 C. Pressurized tubular creep tests were conducted to evaluate multiaxial creep-rupture response of the material. Over 800,000 hours of creep test data were generated during the test program with the longest rupture tests extending beyond 38,000 hours, and the longest creep-rate experiments exceeding 40,000 hours

  8. Ligament rupture and unstable burst behaviors of axial flaws in steam generator U-bends

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Chi Bum, E-mail: bahn@pusan.ac.kr [Pusan National University, 2 Busandaehak-ro 63 beon-gil, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Oh, Young-Jin [KEPCO Engineering & Construction Co. Inc., Seongnam 463-870 (Korea, Republic of); Majumdar, Saurin [Argonne National Laboratory, Lemont, IL 60439 (United States)

    2015-11-15

    Highlights: • Ligament rupture and unstable burst pressure tests were conducted with U-bends. • In general, U-bends showed higher ligament rupture and burst pressures than straight tubes. • U-bend test data was bounded by 90% lower limit of the probabilistic models for straight tubes. • Prediction models for straight tubes could be conservatively applied to U-bends. - Abstract: Incidents of U-bend cracking in steam generator (SG) tubes have been reported, some of which have led to tube rupture. Experimental and analytical modeling efforts to determine the failure criteria of flawed SG U-bends are limited. To evaluate structural integrity of flawed U-bends, ligament rupture and unstable burst pressure tests were conducted on 57 and 152 mm bend radius U-bends with axial electrical discharge machining notches. In general, the ligament rupture and burst pressures of the U-bends were higher than those of straight tubes with similar notches. To quantitatively address the test data scatter issue, probabilistic models were introduced. All ligament rupture and burst pressures of U-bends were bounded by 90% lower limits of the probabilistic models for straight tubes. It was concluded that the prediction models for straight tubes could be applied to U-bends to conservatively evaluate the ligament rupture and burst pressures of U-bends with axial flaws.

  9. Ligament rupture and unstable burst behaviors of axial flaws in steam generator U-bends

    International Nuclear Information System (INIS)

    Bahn, Chi Bum; Oh, Young-Jin; Majumdar, Saurin

    2015-01-01

    Highlights: • Ligament rupture and unstable burst pressure tests were conducted with U-bends. • In general, U-bends showed higher ligament rupture and burst pressures than straight tubes. • U-bend test data was bounded by 90% lower limit of the probabilistic models for straight tubes. • Prediction models for straight tubes could be conservatively applied to U-bends. - Abstract: Incidents of U-bend cracking in steam generator (SG) tubes have been reported, some of which have led to tube rupture. Experimental and analytical modeling efforts to determine the failure criteria of flawed SG U-bends are limited. To evaluate structural integrity of flawed U-bends, ligament rupture and unstable burst pressure tests were conducted on 57 and 152 mm bend radius U-bends with axial electrical discharge machining notches. In general, the ligament rupture and burst pressures of the U-bends were higher than those of straight tubes with similar notches. To quantitatively address the test data scatter issue, probabilistic models were introduced. All ligament rupture and burst pressures of U-bends were bounded by 90% lower limits of the probabilistic models for straight tubes. It was concluded that the prediction models for straight tubes could be applied to U-bends to conservatively evaluate the ligament rupture and burst pressures of U-bends with axial flaws.

  10. Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Murthy, Pappu L. N.; Thesken, John C.; Phoenix, S. Leigh; Grimes-Ledesma, Lorie

    2007-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

  11. [Effects of posterior tibial slope on non-contact anterior cruciate ligament rupture and stability of anterior cruciate ligament rupture knee].

    Science.gov (United States)

    Yue, De-bo; E, Sen; Wang, Bai-liang; Wang, Wei-guo; Guo, Wan-shou; Zhang, Qi-dong

    2013-05-07

    To retrospectively explore the correlation between anterior cruciate ligament (ACL)-ruptured knees, stability of ACL-rupture knee and posterior tibial slope (PTS). From January 2008 to October 2012, 150 knees with ACL rupture underwent arthroscopic surgery for ACL reconstruction. A control group was established for subjects undergoing arthroscopic surgery without ACL rupture during the same period. PTS was measured on a digitalized lateral radiograph. Lachman and mechanized pivot shift tests were performed for assessing the stability of knee. There was significant difference (P = 0.007) in PTS angle between the patients with ACL rupture (9.5 ± 2.2 degrees) and the control group (6.6 ± 1.8 degrees). Only among females, increased slope of tibial plateau had effect on the Lachman test. There was a higher positive rate of pivot shift test in patients of increased posterior slope in the ACL rupture group. Increased posterior tibial slope (>6.6) appears to contribute to non-contact ACL injuries in females. And the changes of tibial slope have no effect upon the Lachman test. However, large changes in tibial slope affect pivot shift.

  12. Neck curve polynomials in neck rupture model

    International Nuclear Information System (INIS)

    Kurniadi, Rizal; Perkasa, Yudha S.; Waris, Abdul

    2012-01-01

    The Neck Rupture Model is a model that explains the scission process which has smallest radius in liquid drop at certain position. Old fashion of rupture position is determined randomly so that has been called as Random Neck Rupture Model (RNRM). The neck curve polynomials have been employed in the Neck Rupture Model for calculation the fission yield of neutron induced fission reaction of 280 X 90 with changing of order of polynomials as well as temperature. The neck curve polynomials approximation shows the important effects in shaping of fission yield curve.

  13. Acute Pectoralis Major Rupture Captured on Video

    Directory of Open Access Journals (Sweden)

    Alejandro Ordas Bayon

    2016-01-01

    Full Text Available Pectoralis major (PM ruptures are uncommon injuries, although they are becoming more frequent. We report a case of a PM rupture in a young male who presented with axillar pain and absence of the anterior axillary fold after he perceived a snap while lifting 200 kg in the bench press. Diagnosis of PM rupture was suspected clinically and confirmed with imaging studies. The patient was treated surgically, reinserting the tendon to the humerus with suture anchors. One-year follow-up showed excellent results. The patient was recording his training on video, so we can observe in detail the most common mechanism of injury of PM rupture.

  14. Traumatic rupture of an intracranial dermoid cyst

    Directory of Open Access Journals (Sweden)

    Raksha Ramlakhan, BMedSc, MBBCh

    2015-01-01

    Full Text Available Intracranial dermoid cysts are congenital tumors of ectodermal origin. Rupture of these cysts can occur spontaneously, but rupture in association with trauma is reported infrequently. The diagnosis of rupture is made by the presence of lipid (cholesterol droplets in the subarachnoid spaces and ventricles. Nonenhanced CT of the head demonstrates multiple foci of low attenuation that correspond with hyperintense signal on T1-weighted MRI. We present a case of an adult patient with rupture of an intracranial dermoid cyst, precipitated by minor trauma.

  15. CT diagnosis of ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sacknoff, R.; Novelline, R.A.; Wittenberg, J.; Waltman, A.C.; De Luca, S.A.; Rhea, J.T.; Lawrason, J.N.

    1986-01-01

    Ruptured abdominal aortic aneurysm (AAA) is a life-threatening condition requiring immediate diagnosis and surgery. In a series of 23 consecutive patients scanned by CT for suspected ruptured AAA, CT proved 100% accurate. In seven patients with surgically or pathologically proved ruptured AAA, CT demonstrated a similar distribution of hemorrhage into the perirenal space and to a lesser degree into the anterior and posterior pararenal spaces. The 16 true-negative examinations included ten in patients with unruptured AAA and six in patients with other diseases. The authors conclude that patients in stable condition with suspected ruptured AAA should be examined by CT

  16. The SCEC/USGS dynamic earthquake rupture code verification exercise

    Science.gov (United States)

    Harris, R.A.; Barall, M.; Archuleta, R.; Dunham, E.; Aagaard, Brad T.; Ampuero, J.-P.; Bhat, H.; Cruz-Atienza, Victor M.; Dalguer, L.; Dawson, P.; Day, S.; Duan, B.; Ely, G.; Kaneko, Y.; Kase, Y.; Lapusta, N.; Liu, Yajing; Ma, S.; Oglesby, D.; Olsen, K.; Pitarka, A.; Song, S.; Templeton, E.

    2009-01-01

    Numerical simulations of earthquake rupture dynamics are now common, yet it has been difficult to test the validity of these simulations because there have been few field observations and no analytic solutions with which to compare the results. This paper describes the Southern California Earthquake Center/U.S. Geological Survey (SCEC/USGS) Dynamic Earthquake Rupture Code Verification Exercise, where codes that simulate spontaneous rupture dynamics in three dimensions are evaluated and the results produced by these codes are compared using Web-based tools. This is the first time that a broad and rigorous examination of numerous spontaneous rupture codes has been performed—a significant advance in this science. The automated process developed to attain this achievement provides for a future where testing of codes is easily accomplished.Scientists who use computer simulations to understand earthquakes utilize a range of techniques. Most of these assume that earthquakes are caused by slip at depth on faults in the Earth, but hereafter the strategies vary. Among the methods used in earthquake mechanics studies are kinematic approaches and dynamic approaches.The kinematic approach uses a computer code that prescribes the spatial and temporal evolution of slip on the causative fault (or faults). These types of simulations are very helpful, especially since they can be used in seismic data inversions to relate the ground motions recorded in the field to slip on the fault(s) at depth. However, these kinematic solutions generally provide no insight into the physics driving the fault slip or information about why the involved fault(s) slipped that much (or that little). In other words, these kinematic solutions may lack information about the physical dynamics of earthquake rupture that will be most helpful in forecasting future events.To help address this issue, some researchers use computer codes to numerically simulate earthquakes and construct dynamic, spontaneous

  17. Detection and location of can rupture in reactors cooled by a flow of water

    International Nuclear Information System (INIS)

    Le Meur, R.

    1968-01-01

    This report brings together the principal methods of fission-product detection used for water reactors. The position, type and method of adjustment is given for each detector. The methods for localizing the defective elements are explained, in particular those using water sampling or decreases in the flux. A few installations are briefly described. They correspond to particular types of reactors using boiling, pressurized or cold water. Amongst the many methods used, it can be noted that when the fuel is resistant, the installations are fairly compact. In nuclear super-heated reactors on the other hand, the study of fuel behaviour calls for larger installations. An identification of defective elements exists when the reactor structure allows it. If this is not possible, a localization in a group of elements is obtained by a flux depression. (author) [fr

  18. Analytical evaluation of the environment effect on creep rupture strength

    International Nuclear Information System (INIS)

    Tamura, Manabu; Ogawa, Yutaka; Kurata, Yuji; Kondo, Tatsuo

    1982-04-01

    An analytical approach was made in evaluating semi-quantitatively the effect of environment on rupture strength of materials. In the analysis the zone formed in the material by reaction with the environment was assumed to bear the applied load as one of the strength members. In calculations a law of mixtures of creep strength and the linear damage rule were applied. In the modeling of the load bearing by the composite structure of the environment-affected and intact zones, both parallel and series models were considered to formulate the equations. The equation for the parallel-loaded model was properly adopted in explaining semi-quantitatively the case of Incoloy alloy 800 crept in air, which was strengthened with the layer formed by nitrization. The equation for the serially loaded model was more successfully adopted to the evaluation of the rupture strength of dissimilar weld joints. The latter was also considered to be potentially adoptable to the problems of the effect of specimen size and shape on rupture strength, which had been often taken into account in evaluating the environment effect. For application of the developed method, examination was made to the possible decrease in rupture strength of Hastelloy alloy XR in long term tests by the formation of Cr depleted zone due to oxidation in HTGR impure helium, and the results were compared with the values obtained by experiments. (author)

  19. Creep and creep-rupture behavior of Alloy 718

    International Nuclear Information System (INIS)

    Brinkman, C.R.; Booker, M.K.; Ding, J.L.

    1991-01-01

    Data obtained from creep and creep-rupture tests conducted on 18 heats of Alloy 718 were used to formulate models for predicting high temperature time dependent behavior of this alloy. Creep tests were conducted on specimens taken from a number of commercial product forms including plate, bar, and forgoing material that had been procured and heat treated in accordance with ASTM specifications B-670 or B-637. Data were obtained over the temperature range of 427 to 760 degree C ad at test times to about 87,000 h. Comparisons are given between experimental data and the analytical models. The analytical models for creep-rupture included one based on lot-centering regression analysis and two based on the Minimum Commitment Method. A ''master'' curve approach was used to develop and equation for estimating creep deformation up to the onset of tertiary creep. 11 refs., 13 figs

  20. Turning points in reactor design

    International Nuclear Information System (INIS)

    Beckjord, E.S.

    1995-01-01

    This article provides some historical aspects on nuclear reactor design, beginning with PWR development for Naval Propulsion and the first commercial application at Yankee Rowe. Five turning points in reactor design and some safety problems associated with them are reviewed: (1) stability of Dresden-1, (2) ECCS, (3) PRA, (4) TMI-2, and (5) advanced passive LWR designs. While the emphasis is on the thermal-hydraulic aspects, the discussion is also about reactor systems

  1. Turning points in reactor design

    Energy Technology Data Exchange (ETDEWEB)

    Beckjord, E.S.

    1995-09-01

    This article provides some historical aspects on nuclear reactor design, beginning with PWR development for Naval Propulsion and the first commercial application at Yankee Rowe. Five turning points in reactor design and some safety problems associated with them are reviewed: (1) stability of Dresden-1, (2) ECCS, (3) PRA, (4) TMI-2, and (5) advanced passive LWR designs. While the emphasis is on the thermal-hydraulic aspects, the discussion is also about reactor systems.

  2. Creep-rupture-test on the stainless steel X6crni1811 (Din 1.494.8) in the frame of the Extrapolation-Program. (Part III); Ensayos de fluencia lenta en el acero inoxidable X6 Cr Ni 1811 (1.4948) en el marco del Programa Extrapolacion

    Energy Technology Data Exchange (ETDEWEB)

    Solano, R; Schirra, M; Rivas, M de la; Barroso, S; Seith, B

    1982-07-01

    The austenitic stainless steel X6crni1811 (Din 1.4948) used as a structure material for the German Fast Breeder Reactor SNR 300 was creep tested in a temperature range of 550-650 degree centigree material condition as well as welded material condition. The main point of this program (Extrapolation-Program) lies in the knowledge of the creep-rupture-strength and creep-behaviour up to 3 x 10{sup 4} hours higher temperatures in order to extrapolated up to {>=}10{sup 5} hours for operating temperatures. In order to study the stress dependency of the minimum creep rate additional tests were carried out of 550 degree centigree - 750 degree centigree. The present report describes the state in the running program with test-times of 23.000 hours and results from tests up to 55.000 hours belonging to other parallel programs are taken into account. Besides the creep-rupture behaviour it is also made a study of ductility between 550 and 750 degree centigree. Extensive metallographic examinations have been made to study the fracture behaviour and changes in structure. (Author)

  3. Common and uncommon CT findings in rupture and impending rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Ahmed, M.Z.; Ling, L.; Ettles, D.F.

    2013-01-01

    The rapid imaging evaluation and diagnosis of rupture and impending rupture of an abdominal aortic aneurysm (AAA) is imperative. This article describes the imaging findings of rupture, impending rupture, and other abdominal aortic abnormalities. It is important not to overlook AAA as the consequences can be life threatening. All patients who had open or endovascular repair of AAA rupture over 6 years (2008–2012) were identified from our departmental database. The computed tomography (CT) images of 99 patients were reviewed for relevant findings. The mean age of the patients was 65 years and 85% were male

  4. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  5. Rupture of esophagus by compressed air.

    Science.gov (United States)

    Wu, Jie; Tan, Yuyong; Huo, Jirong

    2016-11-01

    Currently, beverages containing compressed air such as cola and champagne are widely used in our daily life. Improper ways to unscrew the bottle, usually by teeth, could lead to an injury, even a rupture of the esophagus. This letter to editor describes a case of esophageal rupture caused by compressed air.

  6. Coiling of ruptured pericallosal artery aneurysms.

    NARCIS (Netherlands)

    Menovsky, T.; Rooij, W.J.J. van; Sluzewski, M.; Wijnalda, D.

    2002-01-01

    OBJECTIVE: To assess the technical feasibility of treating ruptured pericallosal artery aneurysms with detachable coils and to evaluate the anatomic and clinical results. METHODS: Over a period of 27 months, 12 patients with a ruptured pericallosal artery aneurysm were treated with detachable

  7. Treatment Alternative for Irreparable Rotator Cuff Ruptures ...

    African Journals Online (AJOL)

    2016-09-03

    Sep 3, 2016 ... and such ruptures also lead to a pseudo-paralysis.[1,2]. Pain during daily ... 2) repairable rotator cuff rupture, as determined on MRI and during arthroscopy ..... functioning and lead to cosmetic deformities.[4]. Arthroplasty is a ...

  8. Uterine rupture without previous caesarean delivery

    DEFF Research Database (Denmark)

    Thisted, Dorthe L. A.; H. Mortensen, Laust; Krebs, Lone

    2015-01-01

    to uterine rupture when adjusted for parity, epidural analgesia and augmentation by oxytocin. CONCLUSION: Although uterine rupture is rare, its association with epidural analgesia and augmentation of labour with oxytocin in multipara should be considered. Thus, vigilance should be exercised when labour...

  9. Spontaneous rupture of choledochal cyst: case report

    International Nuclear Information System (INIS)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young

    2002-01-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued

  10. Isolated gallbladder rupture following blunt abdominal injury

    African Journals Online (AJOL)

    2015-05-26

    May 26, 2015 ... Kaohsiung Medical University, Kaohsiung, Taiwan. Abstract. Isolated traumatic gallbladder rupture subsequent to blunt abdominal injury is rare. Most literatures on the subjects consist of case reports. We reported a rare case of isolated gallbladder rupture and discussed the possible predisposing factors to ...

  11. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  12. Spontaneous rupture of choledochal cyst: case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young [Dong-a University College of Medicine, Pusan (Korea, Republic of)

    2002-11-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued.

  13. Spontaneous rupture of adrenal metastasis from hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chae Hun; Kim, Hyun Jin; Park, Soo Youn; Hwang, Seong Su; Choi, Hyun Joo [St. Vincent Hospital, Suwon (Korea, Republic of)

    2007-03-15

    Rupture of adrenal tumor from various primary origins is a rather rare event. We report here on a ruptured adrenal metastasis from hepatocellular carcinoma, and this ruptured metastasis was observed at the time of the initial diagnosis.

  14. Triple Achilles Tendon Rupture: Case Report.

    Science.gov (United States)

    Saxena, Amol; Hofer, Deann

    We present a case report with 1-year follow-up data of a 57-year-old male soccer referee who had sustained an acute triple Achilles tendon rupture injury during a game. His triple Achilles tendon rupture consisted of a rupture of the proximal watershed region, a rupture of the main body (mid-watershed area), and an avulsion-type rupture of insertional calcific tendinosis. The patient was treated surgically with primary repair of the tendon, including tenodesis with anchors. Postoperative treatment included non-weightbearing for 4 weeks and protected weightbearing until 10 weeks postoperative, followed by formal physical therapy, which incorporated an "antigravity" treadmill. The patient was able to return to full activity after 26 weeks, including running and refereeing, without limitations. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  16. Ruptured gastroepiploic artery aneurysm: A case report

    Directory of Open Access Journals (Sweden)

    Ahmad S. Ashrafi

    Full Text Available Introduction: Gastroepiploic artery aneurysms are extremely rare, with few reported cases in the literature. The risk of rupture however, is high and thus warrants attention. Presentation of case: Here we present a rare case of a women who presented to the emergency department in shock and was found to have a ruptured gastroepiploic artery aneurysm during surgical exploration. Suture ligation of the aneurysm was completed. Discussion: Although rare, gastroepiploic artery aneurysms have up to a 90% rate of rupture and therefore require intervention. A laparoscopic approach has been described however, in cases where rupture has occurred, urgent laparotomy and control of hemorrhage is needed. Conclusion: We describe a rare case of a ruptured gastroepiploic aneurysm that was successfully managed with urgent laparotomy and aneurysmal resection. Keywords: Gastroepiploic, Aneurysm, Hemorrhage, Case report

  17. Earthquake lights and rupture processes

    Directory of Open Access Journals (Sweden)

    T. V. Losseva

    2005-01-01

    Full Text Available A physical model of earthquake lights is proposed. It is suggested that the magnetic diffusion from the electric and magnetic fields source region is a dominant process, explaining rather high localization of the light flashes. A 3D numerical code allowing to take into account the arbitrary distribution of currents caused by ground motion, conductivity in the ground and at its surface, including the existence of sea water above the epicenter or (and near the ruptured segments of the fault have been developed. Simulations for the 1995 Kobe earthquake were conducted taking into account the existence of sea water with realistic geometry of shores. The results do not contradict the eyewitness reports and scarce measurements of the electric and magnetic fields at large distances from the epicenter.

  18. Rupture of the meniscofibular ligament

    Directory of Open Access Journals (Sweden)

    Poyanli Oguz

    2010-05-01

    Full Text Available Abstract The meniscofibular ligament is an anatomically defined ligament of the knee in humans. However, there are no data regarding the prognosis following injury to this ligament. Our case was a 42-year-old man who presented at our clinic with pain of the lateral side of his left knee. MRI of his left knee revealed the rupture of the meniscofibular ligament. The mechanism of injury was consistent with anatomical and mechanical studies of the meniscofibular ligament. The patient was treated conservatively for 1 year, but his pain did not resolve completely. A case series of patients with the same injury is required to establish an effective treatment for this rare injury.

  19. Dynamic Rupture Benchmarking of the ADER-DG Method

    Science.gov (United States)

    Gabriel, Alice; Pelties, Christian

    2013-04-01

    We will verify the arbitrary high-order derivative Discontinuous Galerkin (ADER-DG) method in various test cases of the 'SCEC/USGS Dynamic Earthquake Rupture Code Verification Exercise' benchmark suite (Harris et al. 2009). The ADER-DG scheme is able to solve the spontaneous rupture problem with high-order accuracy in space and time on three-dimensional unstructured tetrahedral meshes. Strong mesh coarsening or refinement at areas of interest can be applied to keep the computational costs feasible. Moreover, the method does not generate spurious high-frequency contributions in the slip rate spectra and therefore does not require any artificial damping as demonstrated in previous presentations and publications (Pelties et al. 2010 and 2012). We will show that the mentioned features hold also for more advanced setups as e.g. a branching fault system, heterogeneous background stresses and bimaterial faults. The advanced geometrical flexibility combined with an enhanced accuracy will make the ADER-DG method a useful tool to study earthquake dynamics on complex fault systems in realistic rheologies. References: Harris, R.A., M. Barall, R. Archuleta, B. Aagaard, J.-P. Ampuero, H. Bhat, V. Cruz-Atienza, L. Dalguer, P. Dawson, S. Day, B. Duan, E. Dunham, G. Ely, Y. Kaneko, Y. Kase, N. Lapusta, Y. Liu, S. Ma, D. Oglesby, K. Olsen, A. Pitarka, S. Song, and E. Templeton, The SCEC/USGS Dynamic Earthquake Rupture Code Verification Exercise, Seismological Research Letters, vol. 80, no. 1, pages 119-126, 2009 Pelties, C., J. de la Puente, and M. Kaeser, Dynamic Rupture Modeling in Three Dimensions on Unstructured Meshes Using a Discontinuous Galerkin Method, AGU 2010 Fall Meeting, abstract #S21C-2068 Pelties, C., J. de la Puente, J.-P. Ampuero, G. Brietzke, and M. Kaeser, Three-Dimensional Dynamic Rupture Simulation with a High-order Discontinuous Galerkin Method on Unstructured Tetrahedral Meshes, JGR. - Solid Earth, VOL. 117, B02309, 2012

  20. The Danish anal sphincter rupture questionnaire: Validity and reliability

    DEFF Research Database (Denmark)

    Due, Ulla; Ottesen, Marianne

    2008-01-01

    Objective. To revise, validate and test for reliability an anal sphincter rupture questionnaire in relation to construct, content and face validity. Setting and background. Since 1996 women with anal sphincter rupture (ASR) at one of the public university hospitals in Copenhagen, Denmark have been...... main questions but one. Two questions needed further explanation. Seven women made minor errors. Conclusion. The validated Danish questionnaire has a good construct, content and face validity. It is a well accepted, reliable, simple and clinically relevant screening tool. It reveals physical problems...... offered pelvic floor muscle examination and instruction by a specialist physiotherapist. In relation to that, a non-validated questionnaire about anal and urinary incontinence was to be answered six months after childbirth. Method. The original questionnaire was revised and a pilot test was performed...

  1. Effect of heating method on stress-rupture life

    Science.gov (United States)

    Bizon, P. T.; Calfo, F. D.

    1977-01-01

    The effect of radiant(furnace), resistance(electric current), burner(hot gas stream), and a combination of resistance and burner heating on intermediate time (100 to 300 hr) stress-rupture life and reduction of area was evaluated. All heating methods were studied using the nickel-based alloy Udimet 700 while all but burner heating were evaluated with the cobalt-based alloy Mar-M 509. Limited test results of eight other superalloys were also included in this study. Resistance heated specimens had about 20 to 30 percent of the stress-rupture life of radiant heated specimens. The limited burner heating data showed about a 50 percent life reduction as compared to the radiant heated tests. A metallurgical examination gave no explanation for these reductions.

  2. Shared and Distinct Rupture Discriminants of Small and Large Intracranial Aneurysms.

    Science.gov (United States)

    Varble, Nicole; Tutino, Vincent M; Yu, Jihnhee; Sonig, Ashish; Siddiqui, Adnan H; Davies, Jason M; Meng, Hui

    2018-04-01

    Many ruptured intracranial aneurysms (IAs) are small. Clinical presentations suggest that small and large IAs could have different phenotypes. It is unknown if small and large IAs have different characteristics that discriminate rupture. We analyzed morphological, hemodynamic, and clinical parameters of 413 retrospectively collected IAs (training cohort; 102 ruptured IAs). Hierarchal cluster analysis was performed to determine a size cutoff to dichotomize the IA population into small and large IAs. We applied multivariate logistic regression to build rupture discrimination models for small IAs, large IAs, and an aggregation of all IAs. We validated the ability of these 3 models to predict rupture status in a second, independently collected cohort of 129 IAs (testing cohort; 14 ruptured IAs). Hierarchal cluster analysis in the training cohort confirmed that small and large IAs are best separated at 5 mm based on morphological and hemodynamic features (area under the curve=0.81). For small IAs (IAs (area under the curve=0.84; 95% confidence interval, 0.78-0.88), whereas for large IAs (≥5 mm), the model included undulation index, low wall shear stress, previous subarachnoid hemorrhage, and IA location (area under the curve=0.87; 95% confidence interval, 0.82-0.93). The model for the aggregated training cohort retained all the parameters in the size-dichotomized models. Results in the testing cohort showed that the size-dichotomized rupture discrimination model had higher sensitivity (64% versus 29%) and accuracy (77% versus 74%), marginally higher area under the curve (0.75; 95% confidence interval, 0.61-0.88 versus 0.67; 95% confidence interval, 0.52-0.82), and similar specificity (78% versus 80%) compared with the aggregate-based model. Small (IAs have different hemodynamic and clinical, but not morphological, rupture discriminants. Size-dichotomized rupture discrimination models performed better than the aggregate model. © 2018 American Heart Association, Inc.

  3. Influence of steam generator tube ruptures during semiscale loss-of-coolant experiments

    International Nuclear Information System (INIS)

    Cozzuol, J.M.; Larson, T.K.

    1978-01-01

    Examination of the U-tubes in the steam generators of some large commercial pressurized water reactors (PWR) has revealed the existence of leakage and in some cases structural weakening of the tubes. This structural weakening enhances the possibility of tubes rupturing during a hypothesized loss-of-coolant accident (LOCA). Considerable interest has been shown in the analysis of tube ruptures concurrent with a hypothesized LOCA since the presence of tube ruptures has the potential to influence the system thermal-hydraulic response and could foreseeably result in a more severe core thermal behavior than might otherwise occur. To experimentally investigate the influence of steam generator tube ruptures on the thermal-hydraulic response of PWR type system, a series of experiments was conducted in the Semiscale Mod-1 system by EG and G Idaho, Inc., for the U.S. Nuclear Regulatory Commission and the Department of Energy. The primary objective of the experiments was to obtain data which could be used to evaluate the influence of the simulated tube ruptures on the system and core thermal-hydraulic response for a range of tube ruptures that was expected to provide the potential for high cladding temperatures in the Semiscale facility. The experiments were conducted assuming a variety in the number of tubes ruptured during large break loss-of-coolant conditions. The number of experiments conducted permitted determination of the range of tube ruptures for which high peak cladding temperatures could result in the Semiscale Mod-1 system. The paper contains a description of the Semiscale Mod-1 system and a discussion of the steam generator tube rupture tests conducted. The experimental results from the test series and the thermal-hydraulic phenomena found to influence the core thermal response during the experiments are discussed

  4. Tests of Neutron Spectrum Calculations with the Help of Foil Measurements in a D{sub 2}O and in an H{sub 2}O-Moderated Reactor and in Reactor Shields of Concrete an Iron

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, R; Aalto, E

    1964-09-15

    Foil measurements covering the fast, epithermal and thermal neutron energy regions have been made in the centre of the Swedish D{sub 2}O-moderated reactor R1, in the pool reactor R2-0, and in different positions in reactor shields of iron, magnetite concrete and ordinary concrete. Neutron spectra have also been calculated for most of these positions, often with the help of a numerical integration of the Boltzmann equation. The measurements and the calculated spectra are presented.

  5. Rupture Complexity Promoted by Damaged Fault Zones in Earthquake Cycle Models

    Science.gov (United States)

    Idini, B.; Ampuero, J. P.

    2017-12-01

    Pulse-like ruptures tend to be more sensitive to stress heterogeneity than crack-like ones. For instance, a stress-barrier can more easily stop the propagation of a pulse than that of a crack. While crack-like ruptures tend to homogenize the stress field within their rupture area, pulse-like ruptures develop heterogeneous stress fields. This feature of pulse-like ruptures can potentially lead to complex seismicity with a wide range of magnitudes akin to the Gutenberg-Richter law. Previous models required a friction law with severe velocity-weakening to develop pulses and complex seismicity. Recent dynamic rupture simulations show that the presence of a damaged zone around a fault can induce pulse-like rupture, even under a simple slip-weakening friction law, although the mechanism depends strongly on initial stress conditions. Here we aim at testing if fault zone damage is a sufficient ingredient to generate complex seismicity. In particular, we investigate the effects of damaged fault zones on the emergence and sustainability of pulse-like ruptures throughout multiple earthquake cycles, regardless of initial conditions. We consider a fault bisecting a homogeneous low-rigidity layer (the damaged zone) embedded in an intact medium. We conduct a series of earthquake cycle simulations to investigate the effects of two fault zone properties: damage level D and thickness H. The simulations are based on classical rate-and-state friction, the quasi-dynamic approximation and the software QDYN (https://github.com/ydluo/qdyn). Selected fully-dynamic simulations are also performed with a spectral element method. Our numerical results show the development of complex rupture patterns in some damaged fault configurations, including events of different sizes, as well as pulse-like, multi-pulse and hybrid pulse-crack ruptures. We further apply elasto-static theory to assess how D and H affect ruptures with constant stress drop, in particular the flatness of their slip profile

  6. Metrics for comparing dynamic earthquake rupture simulations

    Science.gov (United States)

    Barall, Michael; Harris, Ruth A.

    2014-01-01

    Earthquakes are complex events that involve a myriad of interactions among multiple geologic features and processes. One of the tools that is available to assist with their study is computer simulation, particularly dynamic rupture simulation. A dynamic rupture simulation is a numerical model of the physical processes that occur during an earthquake. Starting with the fault geometry, friction constitutive law, initial stress conditions, and assumptions about the condition and response of the near‐fault rocks, a dynamic earthquake rupture simulation calculates the evolution of fault slip and stress over time as part of the elastodynamic numerical solution (Ⓔ see the simulation description in the electronic supplement to this article). The complexity of the computations in a dynamic rupture simulation make it challenging to verify that the computer code is operating as intended, because there are no exact analytic solutions against which these codes’ results can be directly compared. One approach for checking if dynamic rupture computer codes are working satisfactorily is to compare each code’s results with the results of other dynamic rupture codes running the same earthquake simulation benchmark. To perform such a comparison consistently, it is necessary to have quantitative metrics. In this paper, we present a new method for quantitatively comparing the results of dynamic earthquake rupture computer simulation codes.

  7. Hepatic Rupture Induced by Spontaneous Intrahepatic Hematoma

    Directory of Open Access Journals (Sweden)

    Jin-bao Zhou

    2018-01-01

    Full Text Available The etiology of hepatic rupture is usually secondary to trauma, and hepatic rupture induced by spontaneous intrahepatic hematoma is clinically rare. We describe here a 61-year-old female patient who was transferred to our hospital with hepatic rupture induced by spontaneous intrahepatic hematoma. The patient had no history of trauma and had a history of systemic lupus erythematosus for five years, taking a daily dose of 5 mg prednisone for treatment. The patients experienced durative blunt acute right upper abdominal pain one day after satiation, which aggravated in two hours, accompanied by dizziness and sweating. Preoperative diagnosis was rupture of the liver mass. Laparotomy revealed 2500 mL fluid consisting of a mixture of blood and clot in the peritoneal cavity. A 3.5 cm × 2.5 cm rupture was discovered on the hepatic caudate lobe near the vena cava with active arterial bleeding, and a 5  × 6 cm hematoma was reached on the right posterior lobe of the liver. Abdominal computed tomography (CT and laparotomy revealed spontaneous rupture of intrahepatic hematoma with hemorrhagic shock. The patient was successfully managed by suturing the rupture of the hepatic caudate lobe and clearing part of the hematoma. The postoperative course was uneventful, and the patient was discharged after two weeks of hospitalization.

  8. Babcock and Wilcox model for predicting in-reactor densification

    International Nuclear Information System (INIS)

    Buescher, B.J.; Pegram, J.W.

    1975-06-01

    The B and W fuel densification model is used to describe the extent and kinetics of in-reactor densification in B and W production fuel. The model and approach are qualified against an extensive data base available through B and W's participation in the EEI Fuel Densification Program. Out-of-reactor resintering tests on representative pellets from each batch of fuel are used to provide input parameters to the B and W densification model. The B and W densification model predicts in-reactor densification very accurately for pellets operated at heat rates above 5 kW/ft and with considerable conservation for pellets operated at heat rates less than 5 kW/ft. This model represents a technically rigorous and conservative basis for predicting the extent and kinetics of in-reactor densification. 9 references. (U.S.)

  9. The diagnostic value of the lactate concentration in the vaginal fluid for diagnosis of premature rupture of membranes

    Directory of Open Access Journals (Sweden)

    N Nazari

    2013-11-01

    Conclusion: Test of Lactate concentration in vaginal fluid test is a valid, quick and easy with high sensitivity and specificity for the diagnosis of premature rupture of membranes the fetus of pregnant women.

  10. Misdiagnosed Chest Pain: Spontaneous Esophageal Rupture

    Science.gov (United States)

    Inci, Sinan; Gundogdu, Fuat; Gungor, Hasan; Arslan, Sakir; Turkyilmaz, Atila; Eroglu, Atila

    2013-01-01

    Chest pain is one of themost common complaints expressed by patients presenting to the emergency department, and any initial evaluation should always consider life-threatening causes. Esophageal rupture is a serious condition with a highmortality rate. If diagnosed, successful therapy depends on the size of the rupture and the time elapsed between rupture and diagnosis.We report on a 41-year-old woman who presented to the emergency department complaining of left-sided chest pain for two hours. PMID:27122690

  11. Spontaneous distal rupture of the plantar fascia.

    Science.gov (United States)

    Gitto, Salvatore; Draghi, Ferdinando

    2018-07-01

    Spontaneous ruptures of the plantar fascia are uncommon injuries. They typically occur at its calcaneal insertion and usually represent a complication of plantar fasciitis and local treatment with steroid injections. In contrast, distal ruptures commonly result from traumatic injuries. We describe the case of a spontaneous distal rupture of the plantar fascia in a 48-year-old woman with a low level of physical activity and no history of direct injury to the foot, plantar fasciitis, or steroid injections. © 2017 Wiley Periodicals, Inc.

  12. Real-Time Detection of Rupture Development: Earthquake Early Warning Using P Waves From Growing Ruptures

    Science.gov (United States)

    Kodera, Yuki

    2018-01-01

    Large earthquakes with long rupture durations emit P wave energy throughout the rupture period. Incorporating late-onset P waves into earthquake early warning (EEW) algorithms could contribute to robust predictions of strong ground motion. Here I describe a technique to detect in real time P waves from growing ruptures to improve the timeliness of an EEW algorithm based on seismic wavefield estimation. The proposed P wave detector, which employs a simple polarization analysis, successfully detected P waves from strong motion generation areas of the 2011 Mw 9.0 Tohoku-oki earthquake rupture. An analysis using 23 large (M ≥ 7) events from Japan confirmed that seismic intensity predictions based on the P wave detector significantly increased lead times without appreciably decreasing the prediction accuracy. P waves from growing ruptures, being one of the fastest carriers of information on ongoing rupture development, have the potential to improve the performance of EEW systems.

  13. Pengaruh Pemijatan Perineum pada Primigravida terhadap Kejadian Ruptur Perineum saat Persalinan di Bidan Praktek Mandiri di Kota Bengkulu Tahun 2014

    Directory of Open Access Journals (Sweden)

    Wewet Savitri

    2015-01-01

    Full Text Available AbstrakRuptur perineum merupakan salah satu komplikasi persalinan kala II yang dapat menyebabkan disfungsi organ reproduksi wanita, perdarahan dan laserasi. Sebanyak 85% wanita melahirkan pervaginam dapat mengalami ruptur perineum. Salah satu cara mengurangi ruptur perineum adalah dengan melakukan pemijatan perineum untuk meningkatkan kesehatan, aliran darah dan elastisitas perineum. Tujuan penelitian ini adalah untuk menentukan pengaruh pemijatan perineum pada primigravida terhadap kejadian ruptur perineum saat persalinan di Bidan Praktek Mandiri di Kota Bengkulu Tahun 2014. Penelitian ini merupakan penelitian quasi eksperimen dengan metode post test only control group design. Penelitian dilakukan di Bidan Praktek Mandiri (BPM kota Bengkulu dengan subjek 28 orang primigravida usia kehamilan 36 minggu yang terdiri dari 14 orang kelompok intervensi dan 14 orang kelompok kontrol. Penelitian dilakukan dari 10 Maret 2014 hingga 10 Mei 2014, kemudian data dianalisis dengan uji Chi Square. Kejadian ruptur perineum pada kelompok intervensi setelah dilakukan pemijatan perineum hanya 21,4% sementara pada kelompok kontrol 71,4%. Hasil penelitian membuktikan ada pengaruh pemijatan perineum pada primigravida terhadap kejadian ruptur perineum (p<0,05. Penelitian ini menyimpulkan bahwa pemijatan perineum pada primigravida berpengaruh terhadap kejadian ruptur perineum pada saat persalinan.Kata kunci: pemijatan perineum, primigravida, ruptur perineumAbstractPerineal rupture is one of the second stage of labor complications that can lead to dysfunction of the female reproductive organs, bleeding and lacerations. As many as 85% of women give birth vaginally may experience rupture of the perineum. A method of reduce perineal rupture is a perineal massage to promote health, blood flow and elasticity of the perineum. The objekctive of this study was to determine the effect of perineal massage on the incidence of perineal rupture in primigravid during childbirth in

  14. Analysis of the FFTF primary pipe rupture transients

    International Nuclear Information System (INIS)

    Perkins, K.R.; Bari, R.A.; Chen, L.C.; Albright, D.C.

    1979-01-01

    The response of the Fast Flux Test Facility (FFTF) to hypothetical ruptures of the high pressure primary piping has been analyzed using two LMFBR plant systems codes, namely IANUS and DEMO. Comparisons of the average channel temperatures predicted by the two codes show good agreement for identical transients. However, the hot channel temperatures predicted by DEMO are about 60K higher than the corresponding IANUS predictions for severe transients. This difference is attributed to the dynamic hot channel factors employed in DEMO which discount the thermal inertia of the duct walls for rapid transients. DEMO also predicts more severe transients for hot-leg ruptures in FFTF than previously reported analyses for the CRBR

  15. A suite of exercises for verifying dynamic earthquake rupture codes

    Science.gov (United States)

    Harris, Ruth A.; Barall, Michael; Aagaard, Brad T.; Ma, Shuo; Roten, Daniel; Olsen, Kim B.; Duan, Benchun; Liu, Dunyu; Luo, Bin; Bai, Kangchen; Ampuero, Jean-Paul; Kaneko, Yoshihiro; Gabriel, Alice-Agnes; Duru, Kenneth; Ulrich, Thomas; Wollherr, Stephanie; Shi, Zheqiang; Dunham, Eric; Bydlon, Sam; Zhang, Zhenguo; Chen, Xiaofei; Somala, Surendra N.; Pelties, Christian; Tago, Josue; Cruz-Atienza, Victor Manuel; Kozdon, Jeremy; Daub, Eric; Aslam, Khurram; Kase, Yuko; Withers, Kyle; Dalguer, Luis

    2018-01-01

    We describe a set of benchmark exercises that are designed to test if computer codes that simulate dynamic earthquake rupture are working as intended. These types of computer codes are often used to understand how earthquakes operate, and they produce simulation results that include earthquake size, amounts of fault slip, and the patterns of ground shaking and crustal deformation. The benchmark exercises examine a range of features that scientists incorporate in their dynamic earthquake rupture simulations. These include implementations of simple or complex fault geometry, off‐fault rock response to an earthquake, stress conditions, and a variety of formulations for fault friction. Many of the benchmarks were designed to investigate scientific problems at the forefronts of earthquake physics and strong ground motions research. The exercises are freely available on our website for use by the scientific community.

  16. Spontaneous rupture of ovarian cystadenocarcinoma: pre- and post-rupture computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Salvadori, Priscila Silveira; Atzingen, Augusto Castelli von; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Bomfim, Lucas Novais [Universidade Tiradentes (UNIT), Maceio, AL, (Brazil)

    2015-09-15

    Epithelial ovarian tumors are the most common malignant ovarian neoplasms and, in most cases, eventual rupture of such tumors is associated with a surgical procedure. The authors report the case of a 54-year-old woman who presented with spontaneous rupture of ovarian cystadenocarcinoma documented by computed tomography, both before and after the event. In such cases, a post-rupture staging tends to be less favorable, compromising the prognosis. (author)

  17. Global catalog of earthquake rupture velocities shows anticorrelation between stress drop and rupture velocity

    Science.gov (United States)

    Chounet, Agnès; Vallée, Martin; Causse, Mathieu; Courboulex, Françoise

    2018-05-01

    Application of the SCARDEC method provides the apparent source time functions together with seismic moment, depth, and focal mechanism, for most of the recent earthquakes with magnitude larger than 5.6-6. Using this large dataset, we have developed a method to systematically invert for the rupture direction and average rupture velocity Vr, when unilateral rupture propagation dominates. The approach is applied to all the shallow (z earthquakes of the catalog over the 1992-2015 time period. After a careful validation process, rupture properties for a catalog of 96 earthquakes are obtained. The subsequent analysis of this catalog provides several insights about the seismic rupture process. We first report that up-dip ruptures are more abundant than down-dip ruptures for shallow subduction interface earthquakes, which can be understood as a consequence of the material contrast between the slab and the overriding crust. Rupture velocities, which are searched without any a-priori up to the maximal P wave velocity (6000-8000 m/s), are found between 1200 m/s and 4500 m/s. This observation indicates that no earthquakes propagate over long distances with rupture velocity approaching the P wave velocity. Among the 23 ruptures faster than 3100 m/s, we observe both documented supershear ruptures (e.g. the 2001 Kunlun earthquake), and undocumented ruptures that very likely include a supershear phase. We also find that the correlation of Vr with the source duration scaled to the seismic moment (Ts) is very weak. This directly implies that both Ts and Vr are anticorrelated with the stress drop Δσ. This result has implications for the assessment of the peak ground acceleration (PGA) variability. As shown by Causse and Song (2015), an anticorrelation between Δσ and Vr significantly reduces the predicted PGA variability, and brings it closer to the observed variability.

  18. Raised Vaginal Fluid Fibronectin Level Indicates Premature Rupture of Membrane

    Directory of Open Access Journals (Sweden)

    Amrita Bhowmik

    2012-07-01

    Full Text Available Background: Premature rupture of membrane (PROM is one of the common complications of pregnancy that has major impact on fetal and neonatal outcome. It is the commonest clinical event where a normal pregnancy becomes suddenly a high-risk one for mother and fetus or neonate. Objective: The study was undertaken to investigate whether raised fibronectin level in vaginal fluid may indicate premature rupture of membrane. Materials and Methods: This cross sectional study was conducted in the department of Obstetrics and Gynecology in Sir Salimullah Medical College & Mitford Hospital, Dhaka during the period of January 2006 to December 2007. A total of 114 pregnant women with gestational age 28th week up to 40th week were included. Sixty were PROM (Group I and 54 were non-PROM (Group II subjects. Fibronectin in vaginal fluid was measured by an immunochemical reaction by nephelometer. Statistical analysis was done by SPSS version 10.0. Results: The PROM patients had significantly higher concentration of fibronectin (225.77 ± 115.18 ng/mL compared to that in non-PROM subjects (8.04 ± 16.17 ng/mL (p < 0.001. Conclusion: It can be concluded that in cases of unequivocal rupture or intactness of the membranes, the result of the fibronectin test corresponds well with the clinical situation. So fibronectin is a sensitive test for detection of amniotic fluid in the vagina.

  19. Acute Iliac Artery Rupture: Endovascular Treatment

    International Nuclear Information System (INIS)

    Chatziioannou, A.; Mourikis, D.; Katsimilis, J.; Skiadas, V.; Koutoulidis, V.; Katsenis, K.; Vlahos, L.

    2007-01-01

    The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft is a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results

  20. Arthrographic diagnosis of ruptured calcaneofibular ligament. I

    International Nuclear Information System (INIS)

    Vuust, M.

    1980-01-01

    A new projection, oblique axial, is recommended for the arthrography of the acute sprained ankle for the correct diagnosis of a ruptured calcaneofibular ligament. Its value is experimentally confirmed. (Auth.)

  1. Right Diaphragm Spontaneous Rupture: A Surgical Approach

    Directory of Open Access Journals (Sweden)

    Duilio Divisi

    2011-01-01

    Full Text Available We present a case of spontaneous rupture of the diaphragm, characterized by nonspecific symptoms. The rapid diagnosis and appropriate surgical approach led to a positive resolution of the pathology.

  2. Traumatic Gallbladder Rupture Treated by Laparoscopic Cholecystectomy

    Science.gov (United States)

    Egawa, Noriyuki; Ueda, Junji; Hiraki, Masatsugu; Ide, Takao; Inoue, Satoshi; Sakamoto, Yuichiro; Noshiro, Hirokazu

    2016-01-01

    Abstract Gallbladder rupture due to blunt abdominal injury is rare. There are few reports of traumatic gallbladder injury, and it is commonly associated with other concomitant visceral injuries. Therefore, it is difficult to diagnose traumatic gallbladder rupture preoperatively when it is caused by blunt abdominal injury. We report a patient who underwent laparoscopic cholecystectomy after an exact preoperative diagnosis of traumatic gallbladder rupture. A 43-year-old man was admitted to our hospital due to blunt abdominal trauma. The day after admission, abdominal pain and ascites increased and a muscular defense sign appeared. Percutaneous drainage of the ascites was performed, and the aspirated fluid was bloody and almost pure bile. He was diagnosed with gallbladder rupture by the cholangiography using the endoscopic retrograde cholangiopancreatography technique. Laparoscopic cholecystectomy was performed safely, and he promptly recovered. If accumulated fluids contain bile, endoscopic cholangiography is useful not only to diagnose gallbladder injury but also to determine the therapeutic strategy. PMID:27462188

  3. Traumatic Gallbladder Rupture Treated by Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Noriyuki Egawa

    2016-05-01

    Full Text Available Gallbladder rupture due to blunt abdominal injury is rare. There are few reports of traumatic gallbladder injury, and it is commonly associated with other concomitant visceral injuries. Therefore, it is difficult to diagnose traumatic gallbladder rupture preoperatively when it is caused by blunt abdominal injury. We report a patient who underwent laparoscopic cholecystectomy after an exact preoperative diagnosis of traumatic gallbladder rupture. A 43-year-old man was admitted to our hospital due to blunt abdominal trauma. The day after admission, abdominal pain and ascites increased and a muscular defense sign appeared. Percutaneous drainage of the ascites was performed, and the aspirated fluid was bloody and almost pure bile. He was diagnosed with gallbladder rupture by the cholangiography using the endoscopic retrograde cholangiopancreatography technique. Laparoscopic cholecystectomy was performed safely, and he promptly recovered. If accumulated fluids contain bile, endoscopic cholangiography is useful not only to diagnose gallbladder injury but also to determine the therapeutic strategy.

  4. Cognitive frames in psychology: demarcations and ruptures.

    Science.gov (United States)

    Yurevich, Andrey V

    2009-06-01

    As there seems to be a recurrent feeling of crisis in psychology, its present state is analyzed in this article. The author believes that in addition to the traditional manifestations that have dogged psychology since it emerged as an independent science some new features of the crisis have emerged. Three fundamental "ruptures" are identified: the "horizontal" rupture between various schools and trends, the "vertical" rupture between natural science and humanitarian psychology, and the "diagonal" rupture between academic research and applied practice of psychology. These manifestations of the crisis of psychology have recently been compounded by the crisis of its rationalistic foundations. This situation is described in terms of the cognitive systems in psychology which include meta-theories, paradigms, sociodigms and metadigms.

  5. Aortic ruptures in seat belt wearers.

    Science.gov (United States)

    Arajärvi, E; Santavirta, S; Tolonen, J

    1989-09-01

    Several investigations have indicated that rupture of the thoracic aorta is one of the leading causes of immediate death in victims of road traffic accidents. In Finland in 1983, 92% of front-seat passengers were seat belt wearers on highways and 82% in build-up areas. The mechanisms of rupture of the aorta have been intensively investigated, but the relationship between seat belt wearing and injury mechanisms leading to aortic rupture is still largely unknown. This study comprises 4169 fatally injured victims investigated by the Boards of Traffic Accident Investigation of Insurance Companies during the period 1972 to 1985. Chest injuries were recorded as the main cause of death in 1121 (26.9%) victims, 207 (5.0%) of those victims having worn a seat belt. Aortic ruptures were found at autopsy in 98 victims and the exact information of the location of the aortic tears was available in 68. For a control group, we analyzed 72 randomly chosen unbelted victims who had a fatal aortic rupture in similar accidents. The location of the aortic rupture in unbelted victims was more often in the ascending aorta, especially in drivers, whereas in seat belt wearers the distal descending aorta was statistically more often ruptured, especially in right-front passengers (p less than 0.05). The steering wheel predominated statistically as the part of the car estimated to have caused the injury in unbelted victims (37/72), and some interior part of the car was the most common cause of fatal thoracic impacts in seat belt wearers (48/68) (p less than 0.001). The mechanism of rupture of the aorta in the classic site just distal to the subclavian artery seems to be rapid deceleration, although complex body movements are also responsible in side impact collisions. The main mechanism leading to rupture of the ascending aorta seems to be severe blow to the bony thorax. This also often causes associated thoracic injuries, such as heart rupture and sternal fracture. Injuries in the ascending

  6. Traumatic Fundal Rupture of unscarred Uterus in a Primigravida ...

    African Journals Online (AJOL)

    Background: Uterine rupture is an infrequent but life threatening obstetric emergency. Rupture of previously scarred uterus is often encountered especially in multiparous women, but the traumatic rupture of an unscarred primigravid uterus as presented here is a relatively rare event. We report a case of rupture of an ...

  7. Describing Soils: Calibration Tool for Teaching Soil Rupture Resistance

    Science.gov (United States)

    Seybold, C. A.; Harms, D. S.; Grossman, R. B.

    2009-01-01

    Rupture resistance is a measure of the strength of a soil to withstand an applied stress or resist deformation. In soil survey, during routine soil descriptions, rupture resistance is described for each horizon or layer in the soil profile. The lower portion of the rupture resistance classes are assigned based on rupture between thumb and…

  8. Micromechanical properties and collagen composition of ruptured human achilles tendon

    DEFF Research Database (Denmark)

    Hansen, Philip; Kovanen, Vuokko; Hölmich, Per

    2013-01-01

    The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.......The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive....

  9. Bladder And Uterine Rupture At Vaginal Birth After Cesarean Section

    African Journals Online (AJOL)

    Rupture of the uterus is still a major obstetric problem in developing countries. The urinary bladder is often affected especially when a lower segment Caesarean scar ruptures. We present a case of bladder rupture associated with uterine rupture in a patient who was attempting vaginal delivery after two previous Caesarean ...

  10. Blunt cardiac rupture in a toddler

    Directory of Open Access Journals (Sweden)

    Peep Talving

    2016-08-01

    Full Text Available Blunt cardiac rupture is typically a fatal injury with overall mortality exceeding 90%. Most of the patients never reach the hospital alive. In pediatric patients, only 0.03% of cases following blunt trauma admissions have a cardiac injury. This report presents a rare survivor of 16-months old toddler injured in a domestic accident suffering a right atrial rupture repaired through a median sternotomy. To the best of our knowledge this is the youngest case reported in the literature.

  11. Treatment strategy for ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  12. Endovascular treatment of ruptured splenic artery aneurysm

    DEFF Research Database (Denmark)

    Bjerring, Ole Steen

    2008-01-01

    Splenic artery aneurysms (SAA) are traditionally treated surgically, but endovascular techniques are becoming increasingly popular. A 64 year-old male with chest pain and low blood pressure was admitted under suspicion of AMI. A CT scan showed a 56 mm SAA with signs of rupture. The patient...... was treated with endovascular embolisation of the SAA with coils. Blood pressure and haemoglobin levels were stabilized and the patient was discharged. In the case of rupture the treatment of choice seems to be endovascular....

  13. Splenic artery aneurysm rupture in pregnancy

    International Nuclear Information System (INIS)

    Khan, H.R.; Low, S.; Selinger, M.; Nelson, N.

    2004-01-01

    Rupture of a splenic artery aneurysm, commonly associated with pregnancy is a rare and catastrophic event. We report here a case of a patient in her second pregnancy who presented with a short history of left hypochondriac and epigastric pain, followed by collapse at 32 weeks gestation. Sudden fetal distress lead to emergency caesarean delivery when splenic artery aneurysm rupture was diagnosed. With timely involvement of multidisciplinary personnel both mother and baby survived and had an uneventful recovery. (author)

  14. Plantar Fascia Rupture: Ultrasound to Facilitate Recognition.

    Science.gov (United States)

    Servey, Jessica T; Jonas, Christopher

    2018-01-01

    Plantar fascia rupture in the absence of previous diagnosis of plantar fasciitis, corticosteroid injection, or injury is a rare occurrence with only 7 case reports in the literature since 1978. This is a case of spontaneous plantar fascia rupture in a 38-year-old active-duty US military member with current considerations in musculoskeletal ultrasound, other radiologic imaging, treatment, and followup of this diagnosis. © Copyright 2018 by the American Board of Family Medicine.

  15. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  16. Ruptured corpus luteal cyst: Prediction of clinical outcomes with CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok; Moon, Min Hoan; Woo, Hyun Sik; Sung, Chang Kyu; Jeon, Hye Won; Lee, Taek Sang [SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    To evaluate the determinant pretreatment CT findings that can predict surgical intervention for patients suffering from corpus luteal cyst rupture with hemoperitoneum. From January 2009 to December 2014, a total of 106 female patients (mean age, 26.1 years; range, 17–44 years) who visited the emergency room of our institute for acute abdominal pain and were subsequently diagnosed with ruptured corpus luteal cyst with hemoperitoneum were included in the retrospective study. The analysis of CT findings included cyst size, cyst shape, sentinel clot sign, ring of fire sign, hemoperitoneum depth, active bleeding in portal phase and attenuation of hemoperitoneum. The comparison of CT findings between the surgery and conservative management groups was performed with the Mann-Whitney U test or chi-square test. Logistic regression analysis was used to determine significant CT findings in predicting surgical intervention for a ruptured cyst. Comparative analysis revealed that the presence of active bleeding and the hemoperitoneum depth were significantly different between the surgery and conservative management groups and were confirmed as significant CT findings for predicting surgery, with adjusted odds ratio (ORs) of 3.773 and 1.318, respectively (p < 0.01). On the receiver-operating characteristic curve analysis for hemoperitoneum depth, the optimal cut-off value was 5.8 cm with 73.7% sensitivity and 58.6% specificity (Az = 0.711, p = 0.004). In cases with a hemoperitoneum depth > 5.8 cm and concurrent active bleeding, the OR for surgery increased to 5.786. The presence of active bleeding and the hemoperitoneum depth on a pretreatment CT scan can be predictive warning signs of surgery for a patient with a ruptured corpus luteal cyst with hemoperitoneum.

  17. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  18. Influence of composition on precipitation behavior and stress rupture properties in INCONEL RTM740 series superalloys

    Science.gov (United States)

    Casias, Andrea M.

    Increasing demands for energy efficiency and reduction in CO2 emissions have led to the development of advanced ultra-supercritical (AUSC) boilers. These boilers operate at temperatures of 760 °C and pressures of 35 MPa, providing efficiencies close to 50 pct. However, austenitic stainless steels typically used in boiler applications do not have sufficient creep or oxidation resistance. For this reason, nickel (Ni)-based superalloys, such as IN740, have been identified as potential materials for AUSC boiler tube components. However, IN740 is susceptible to heat-affected-zone liquation cracking in the base metal of heavy section weldments. To improve weldability, IN740H was developed. However, IN740H has lower stress rupture ductility compared to IN740. For this reason, two IN740H modifications have been produced by lowering carbon content and increasing boron content. In this study, IN740, IN740H, and the two modified IN740H alloys (modified 1 and 2) were produced with equiaxed grain sizes of 90 ìm (alloys IN740, IN740H, and IN740H modified 1 alloys) and 112 µm (IN740H modified 2 alloy). An aging study was performed at 800 °C on all alloys for 1, 3, 10, and 30 hours to assess precipitation behavior. Stress rupture tests were performed at 760 °C with the goal of attaining stress levels that would yield rupture at 1000 hours. The percent reduction in area was measured after failure as a measure of creep ductility. Light optical, scanning electron, and transmission electron microscopy were used in conjunction with X-ray diffraction to examine precipitation behavior of annealed, aged, and stress rupture tested samples. The amount and type of precipitation that occurred during aging prior to stress rupture testing or in-situ during stress rupture testing influenced damage development, stress rupture life, and ductility. In terms of stress rupture life, IN740H modified 2 performed the best followed by IN740H modified 1 and IN740, which performed similarly, and IN740

  19. RESEARCH ON REDUCING PREMATURITY RUPTURE OF MEMBRANE

    Directory of Open Access Journals (Sweden)

    Maria URSACHI (BOLOTA

    2016-12-01

    Full Text Available The membranes surrounding the amniotic cavity are composed from amnion and chorion, tightly adherent layers which are composed of several cell types, including epithelial cells, trophoblasts cells and mesenchyme cells, embedded in a collagenous matrix. They retain amniotic fluid, secret substances into the amniotic fluid, as well as to the uterus and protect the fetus against upward infections from urogenital tract. Normally, the membranes it breaks during labor. Premature rupture of the amniotic sac (PRAS is defined as rupture of membranes before the onset of labor. Premature rupture of the fetal membrane, which occurs before 37 weeks of gestation, usually, refers to preterm premature rupture of membranes. Despite advances in the care period, premature rupture of membranes and premature rupture of membranes preterm continue to be regarded as serious obstetric complications. On the term 8% - 10% of pregnant women have premature rupture of membranes; these women are at increased risk of intrauterine infections, where the interval between membrane rupture and expulsion is rolled-over. Premature rupture of membranes preterm occurs in approximately 1% of all pregnancies and is associated with 30% -40% of preterm births. Thus, it is important to identify the cause of pre-term birth (after less than 37 completed weeks of "gestation" and its complications, including respiratory distress syndrome, neonatal infection and intraventricular hemorrhage. Objectives: the development of the protocol of the clinical trial on patients with impending preterm birth, study clinical and statistical on the socio-demographic characteristics of patients with imminent preterm birth; clinical condition of patients and selection of cases that could benefit from the application of interventional therapy; preclinical investigation (biological and imaging of patients with imminent preterm birth; the modality therapy; clinical investigation of the effectiveness of short

  20. Material Parameters for Creep Rupture of Austenitic Stainless Steel Foils

    Science.gov (United States)

    Osman, H.; Borhana, A.; Tamin, M. N.

    2014-08-01

    Creep rupture properties of austenitic stainless steel foil, 347SS, used in compact recuperators have been evaluated at 700 °C in the stress range of 54-221 MPa to establish the baseline behavior for its extended use. Creep curves of the foil show that the primary creep stage is brief and creep life is dominated by tertiary creep deformation with rupture lives in the range of 10-2000 h. Results are compared with properties of bulk specimens tested at 98 and 162 MPa. Thin foil 347SS specimens were found to have higher creep rates and higher rupture ductility than their bulk specimen counterparts. Power law relationship was obtained between the minimum creep rate and the applied stress with stress exponent value, n = 5.7. The value of the stress exponent is indicative of the rate-controlling deformation mechanism associated with dislocation creep. Nucleation of voids mainly occurred at second-phase particles (chromium-rich M23C6 carbides) that are present in the metal matrix by decohesion of the particle-matrix interface. The improvement in strength is attributed to the precipitation of fine niobium carbides in the matrix that act as obstacles to the movement of dislocations.

  1. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  2. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  3. Arthroscintigraphy in suspected rotator cuff rupture

    International Nuclear Information System (INIS)

    Gratz, S.; Behr, T.; Becker, W.; Koester, G.; Vosshenrich, R.; Grabbe, E.

    1998-01-01

    Aim: In order to evaluate the diagnostic efficiency of arthroscintigraphy in suspected rotator cuff ruptures this new imaging procedure was performed 20 times in 17 patients with clinical signs of a rotator cuff lesion. The scintigraphic results were compared with sonography (n=20), contrast arthrography (n=20) and arthroscopy (n=10) of the shoulder joint. Methods: After performing a standard bone scintigraphy with intravenous application of 300 MBq 99m-Tc-methylene diphosphonate (MDP) for landmarking of the shoulder region arthroscintigraphy was performed after an intraarticular injection of 99m-Tc microcolloid (ALBU-RES 400 μCi/5 ml). The application was performed either in direct combination with contrast arthrography (n=10) or ultrasound conducted mixed with a local anesthetic (n=10). Findings at arthroscopical surgery (n=10) were used as the gold standard. Results: In case of complete rotator cuff rupture (n=5), arthroscintigraphy and radiographic arthrography were identical in 5/5. In one patient with advanced degenerative alterations of the shoulder joint radiographic arthrography incorrectly showed a complete rupture which was not seen by arthroscintigraphy and endoscopy. In 3 patients with incomplete rupture, 2/3 results were consistant. A difference was seen in one patient with a rotator cuff, that has been already revised in the past and that suffered of capsulitis and calcification. Conclusion: Arthroscinitgraphy is a sensitive technique for detection of rotator cuff ruptures. Because of the lower viscosity of the active compound, small ruptures can be easily detected, offering additional value over radiographic arthrography and ultrasound, especially for evaluation of incomplete cuff ruptures. (orig.) [de

  4. The effect of tube rupture location on the consequences of multiple steam generator tube rupture event

    International Nuclear Information System (INIS)

    Jeong, Ji Hwan; Kweon, Young Chul

    2002-01-01

    A multiple steam generator tube rupture (MSGTR) event has never occurred in the commercial operation of nuclear reactors while single steam generator tube rupture (SGTR) events are reported to occur every 2 years. As there has been no occurrence of a MSGTR event, the understanding of transients and consequences of this event is very limited. In this study, a postulated MSGTR event in an advanced power reactor 1400 (APR 1400) is analyzed using the thermal-hydraulic system code, MARS1.4. The APR 1400 is a two-loop, 3893 MWt, PWR proposed to be built in 2010. The present study aims to understand the effects of rupture location in heat transfer tubes following a MSGTR event. The effects of five tube rupture locations are compared with each other. The comparison shows that the response of APR1400 allows the shortest time for operator action following a tube rupture in the vicinity of the hot-leg side tube sheet and allows the longest time following a tube rupture at the tube top. The MSSV lift time for rupture at the tube-top is evaluated as 24.5% larger than that for rupture at the hot-leg side tube sheet

  5. Spontaneous rupture of the esophagus associated with intramural rupture caused by ingestion of weeding medicine (Lasso)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Keon; Park, Heung Il; Kwun, Chung Sik [Chun Nam University College of Medicine, Kwangju (Korea, Republic of)

    1975-06-15

    This is a report of a case of spontaneous rupture of the esophagus associated with intramural rupture caused by ingestion of weeding medicine for the purpose of suicide in a 27 year old Korean male whose chief complaints were dyspnea, epigastric pain, swallowing disturbance, and hoarseness for 3 days prior to admission. A review of literature is submitted.

  6. The extrapolation of creep rupture data by PD6605 - An independent case study

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, J., E-mail: john.bolton@uwclub.net [65 Fisher Avenue, Rugby, Warks CV22 5HW (United Kingdom)

    2011-04-15

    The worked example presented in BSI document PD6605-1:1998, to illustrate the selection, validation and extrapolation of a creep rupture model using statistical analysis, was independently examined. Alternative rupture models were formulated and analysed by the same statistical methods, and were shown to represent the test data more accurately than the original model. Median rupture lives extrapolated from the original and alternative models were found to diverge widely under some conditions of practical interest. The tests prescribed in PD6605 and employed to validate the original model were applied to the better of the alternative models. But the tests were unable to discriminate between the two, demonstrating that these tests fail to ensure reliability in extrapolation. The difficulties of determining when a model is sufficiently reliable for use in extrapolation are discussed and some proposals are made.

  7. Splenic rupture following idiopathic rupture of the urinary bladder presenting as acute abdomen

    Directory of Open Access Journals (Sweden)

    Jurisic D

    2007-01-01

    Full Text Available Idiopathic rupture of the urinary bladder is an uncommon condition and represents less than 1% of all bladder rupture cases. In most of the cases the main etiological factor was heavy alcohol ingestion. A combined injury of the spleen and bladder is a very rare condition that is almost often associated with trauma and foreign bodies. In this paper we present the extremely rare clinical course of acute abdomen caused by a combined spontaneous intraperitoneal injury; spontaneous rupture of the urinary bladder and spleen. According to our opinion, spontaneous bladder rupture caused by bladder distension due to alcohol ingestion led to urinary ascites and abdominal distension. Finally, repeated minor abdominal blunt trauma during everyday life, to a moderately distended abdomen caused a spontaneous splenic rupture in the patient with abnormal coagulation studies.

  8. Evaluation of creep rupture property of high strength ferritic/martensitic steel (PNC-FMS)

    International Nuclear Information System (INIS)

    Uehira, Akihiro; Mizuno, Tomoyasu; Ukai, Shigeharu; Yoshida, Eiichi

    1999-04-01

    High Strength Ferritic/Martensitic Steel (PNC-FMS : 11Cr-0.5Mo-2W,Nb,V), developed by JNC, is one of the candidate materials for the long-life core of large-scale fast breeder reactor. The material design base standard (tentative) of PNC-FMS was established and the creep rupture strength reduction factor in the standard was determined in 1992. This factor was based on only evaluation of decarburization effect on tensile strength after sodium exposure. In this study, creep rupture properties of PNC-FMS under out of pile sodium exposure and in pile were evaluated, using recent test results as well as previous ones. The evaluation results are summarized as follows : a. Decarburization rate constant of pressurized tubes under sodium exposure is identical with stress free specimens. b. In case of the same decarburization content under out of pile sodium exposure, creep strength tends to decrease more significantly than tensile strength. c. Creep strength under out of pile sodium exposure showed significant decrease in high temperature and long exposure time, but in pile (MOTA) creep strength showed little decrease. A new creep rupture strength reduction factor, which is the ratio of creep rupture strength under sodium exposure or in pile to in air, was made by correlating the creep rupture strength. This new method directly using the ratio of creep rupture strength was evaluated and discussed from the viewpoint of design applicability, compared with the conventional method based on decarburization effect on tensile strength. (author)

  9. Maternal serum copper and zinc levels and premature rupture of the foetal membranes

    International Nuclear Information System (INIS)

    Rahmanian, M.; Jahed, F. S.; Yousefi, B.; Ghorbani, R.

    2014-01-01

    Objective: To examine the correlation of zinc and copper serum concentration level, body mass index, age and parity with premature rupture of the membranes. Methods: The cross-sectional study was conducted between 2009 and 2010 at the fertility ward of Amiralmomenin Hospital of Semnan University of Medical Sciences, Iran. It comprised 100 full-term pregnant women with and without premature rupture of the membranes and 50 non-pregnant women as controls. The diagnosis of rupture of membranes was made on the basis of gross leakage of fluid within the vagina and a positive nitrazin test. A sample of 5mL blood was collected. The levels of zinc and copper were determined by an enzyme-linked immunosorbent assay method. Mean values among the three equal groups were compared using standard analysis of variance. Statistical significance was set at p<0.05. Results: Pregnant women with (p<0.027) and without (p<0.019) premature rupture of the membranes had significantly lower serum zinc concentration than non-pregnant women. Inversely, the maternal serum copper concentration level was higher in both groups of pregnant women than in the controls (p<0.001). However, the results suggest that the decreased plasma zinc concentration and increased copper concentration in pregnant women were not the cause of premature rupture of the membranes at term. Conclusion: Zinc and copper concentration levels in maternal serum had no effect on premature rupture of the membranes. (author)

  10. Verification of the computer code ATHLET in the framework of the external verification group ATHLET BETHSY test 9.3 - steam generator U-tube rupture with failure of the high pressure injection. Final report; Verifikation des ATHLET-Rechenprogramms im Rahmen der externen Verifikationsgruppe ATHLET BETHSY Test 9.3 - Heizrohrbruch mit Versagen der Hochdruck-Noteinspeisung. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Krepper, E.; Schaefer, F. [Forschungszentrum Rossendorf e.V. (FZR) (Germany). Inst. fuer Sicherheitsforschung

    1998-08-01

    In the framework of the external validation of the thermalhydraulic code ATHLET MOD 1.1 CYCLE D, which is being developed by the GRS, post test analyses of two experiments were done, which were performed at the French integral test facility BETHSY. During test 9.3 the consequences of a steam generator U-tube rupture with failure of the high pressure injection and of the auxiliary feedwater supply were investigated. As accident management measures, the depressurization of the secondary sides, first of the two intact steam generators, then of the damaged steam generator and finally the primary depressurization by opening of the pressurizer valve were performed. The results show, that the code ATHLET is able to describe the complex scenario in good accordance with the experiment. The safety relevant statement could be reproduced. Deviations, which did not impose the general results, occurred concerning the break mass flow during the depressurization of the damaged steam generator and the description of the failure of the heat transfer to the damaged steam generator. Reasons are hardly to find, because these processes are highly complex. (orig.) [Deutsch] Im Rahmen der externen Validierung des von der Gesellschaft fuer Anlagen- und Reaktorsicherheit entwickelten Stoerfallcodes ATHLET, der in der Version Mod 1.1 Cycle D vorlag, wurden zwei Experimente nachgerechnet und analysiert, die an der franzoesischen Versuchsanlage BETHSY durchgefuehrt wurden. Im Test 9.3 werden die Konsequenzen untersucht, wenn bei einem Heizrohrbruch die Hochdruckeinspeisung sowie die Not-Speisewasserversorgung der Dampferzeuger versagen und nur die Druckspeicher sowie die Niederdruckeinspeisung zur Verfuegung stehen. Als Accident Management Massnahmen wurde die sekundaere Druckentlastung und schliesslich die primaere Entlastung ueber den Druckhalter untersucht. Die Analyse kommt zu dem Ergebnis, dass der Code ATHLET in der Lage ist, dieses komplexe Szenario recht gut zu beschreiben. Die

  11. Radiation exposure doses of employees in reactor facilities for test and research and under research and development stages, and in facilities for nuclear fuel refining, fabrication, reprocessing and usage

    International Nuclear Information System (INIS)

    1980-01-01

    (1) Radiation exposure doses in reactor facilities. The owners of reactor facilities are obliged by law to control the radiation exposure doses of the employees below the permissible levels. The data based on the reports made in this connection are given in tables for the fiscal year 1978 (from April 1978 to March 1979). It was revealed that the radiation exposure doses of the employees were far below the permissible levels. The distributions of exposure doses in Japan Atomic Energy Research Institute, Power Reactor and Nuclear Fuel Development Corporation and so on are presented for the whole year and the respective quarters. (2) Radiation exposure doses in facilities for nuclear fuel. The owners are similarly obliged to control radiation exposure. The data in this connection are given, and the doses were far below the permissible levels. The distributions in the private enterprises and so on are presented for the whole year. (J.P.N.)

  12. Rupture prediction for induction bends under opening mode bending with emphasis on strain localization

    International Nuclear Information System (INIS)

    Mitsuya, Masaki; Sakanoue, Takashi

    2015-01-01

    This study focuses on the opening mode of induction bends; this mode represents the deformation outside a bend. Bending experiments on induction bends are shown and the manner of failure of these bends was investigated. Ruptures occur at the intrados of the bends, which undergo tensile stress, and accompany the local reduction of wall thickness, i.e., necking that indicates strain localization. By implementing finite element analysis (FEA), it was shown that the rupture is dominated not by the fracture criterion of material but by the initiation of strain localization that is a deformation characteristic of the material. These ruptures are due to the rapid increase of local strain after the initiation of strain localization and suddenly reach the fracture criterion. For the evaluation of the deformability of the bends, a method based on FEA that can predict the displacement at the rupture is proposed. We show that the yield surface shape and the true stress–strain relationship after uniform elongation have to be defined on the basis of the actual properties of the bend material. The von Mises yield criterion, which is commonly used in cases of elastic–plastic FEA, could not predict the rupture and overestimated the deformability. In contrast, a yield surface obtained by performing tensile tests on a biaxial specimen could predict the rupture. The prediction of the rupture was accomplished by an inverse calibration method that determined the true stress-strain relationship after uniform elongation. As an alternative to the inverse calibration, a simple extrapolation method of the true stress-strain relationship after uniform elongation which can predict the rupture is proposed. - Highlights: • A method based on FEA that can predict the displacement at the rupture is proposed. • The yield surface shape and the true stress–strain have to be defined precisely. • The von Mises yield criterion overestimated the deformability. • The ruptures are due to the

  13. Ultrasonogram of tubal pregnancy: Unruptured or ruptured?

    International Nuclear Information System (INIS)

    Lee, Hee Jung; Kim, Jung Sik; Lee, Sung Moon; Kim, Hong; Woo, Seong Ku; Yeun, Seong Do; Lee, Doo Ryong

    1993-01-01

    To evaluate the usefulness of ultrasonography in the differentiation of the unruptured ones, we performed prospective ultrasonographic study in 56 patients with tubal pregnancy and subsequently correlated with the surgical (45 cases) and laparoscopic (11 cases) findings. The criterion for unruptured tubal pregnancy was the visualization of extra uterine gestational sac or a mass that was separated from the ipsilateral ovary. All cases were confirmed surgically or laparoscopically within 48 hours after sonographic examination. Forty five (80%)cases were proved as unruptured, tubal pregnancy, while 11 (20%) as ruptured one. Extra uterine gestational sac was seen in 31/45 (69%) in unruptured group and 2/11 (18%) in ruptured group. A mass separated from the ipsilateral ovary was seen in 7 unruptured tubal pregnancies and 2 ruptured pregnancies. A mass that was not separated from the ipsilateral ovary was seen in 13 cases. Seven of these were ruptured pregnancies, while 6 were unrupture dones. Using our criteria, the unruptured tubal pregnancy was diagnosed with a sensitivity of 84%, a specificity of 64%, an accuracy of 80%, a positive predictive value of 90% and a negative predictive value of 50%. We conclude that ultrasonography is useful in the differentiation of the unruptured tubal pregnancy from the ruptured one

  14. Monotonic, Creep-Rupture, and Fatigue Behavior of Carbon Fiber Reinforced Silicon Carbide (C/SiC) at an Elevated Temperature

    National Research Council Canada - National Science Library

    Engesser, John

    2004-01-01

    .... Cyclic loading of C/SiC was investigated at frequencies of 375 Hz, 10 Hz, 1 Hz, and 0.1 Hz. Creep-Rupture tests and tests that were combinations of creep-rupture and fatigue were also accomplished...

  15. Nordic studies in reactor safety

    International Nuclear Information System (INIS)

    Pershagen, N.

    1993-01-01

    The Nordic Nuclear Safety Research Programme SIK programme in reactor safety is part of a major joint Nordic research effort in nuclear safety. The report summarizes the achievements of the SIK programme, which was carried out during 1990-1993 in collaboration between Nordic nuclear utilities, safety authorities, and research institutes. Three main projects were successfully completed dealing with: 1) development and application of a living PSA concept for monitoring the risk of core damage, and of safety indicators for early warning of possible safety problems; 2) review and intercomparison of severe accident codes, case studies of potential core melt accidents in nordic reactors, development of chemical models for the MAAP code, and outline of a system for computerized accident management support; 3) compilation of information about design and safety features of neighbouring reactors in Germany, Lithuania and Russia, and for naval reactors and nuclear submarines. The report reviews the state-of-the-art in each subject matter as an introduction to the individual project summaries. The main findings of each project are highlighted. The report also contains an overview of reactor safety research in the Nordic countries and a summary of fundamental reactor safety principles. (au) (69 refs.)

  16. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mendler, O J; Takeuchi, K; Young, M Y

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results.

  17. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    International Nuclear Information System (INIS)

    Mendler, O.J.; Takeuchi, K.; Young, M.Y.

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results

  18. Bladder rupture caused by postpartum urinary retention.

    Science.gov (United States)

    Dueñas-García, Omar Felipe; Rico, Hugo; Gorbea-Sanchez, Viridiana; Herrerias-Canedo, Tomas

    2008-08-01

    Postpartum bladder rupture is an uncommon surgical emergency and a diagnostic challenge. A primigravida delivered a healthy newborn without complications at 39.4 weeks of gestation. The patient was admitted 80 hours postpartum with abdominal pain, oliguria, hematuria, and pain that worsened during the previous 4 hours. An inserted Foley catheter drained only a small amount of urine, and serum creatinine was elevated (3.5 mg/dL). A laparotomy was performed and revealed a 10-cm hole in the urinary bladder. The bladder was repaired and the patient was discharged 15 days after surgery. The follow-up cystoscopy revealed adequate healing of the bladder. Urinary retention can lead to serious complications, including bladder rupture. Postpartum bladder rupture due to urinary retention should be ruled out if there is a history of abdominal pain, oliguria, and elevated of serum creatinine.

  19. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  20. Right ventricular hydatid cyst ruptured to pericardium

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2015-01-01

    Full Text Available Cardiac hydatidosis is rare presentation of body hydatidosis. Incidence of cardiac involvements range from 5% to 5% of patients with hydatid disease. Most common site of hydatid cyst in heart is interventricular septum and left ventricular free wall. Right ventricular free wall involvement by cyst that ruptured to pericardial cavity is very rare presentation of hydatid cyst. Cardiac involvement may have serious consequences such as rupture to blood steam or pericardial cavity. Both the disease and its surgical treatment carry a high complication rate, including rupture leading to cardiac tamponade, anaphylaxis and also death. In the present report, a 43-year-old man with constrictive pericarditis secondary to a pericardial hydatid cyst is described.

  1. Ruptured Massa Intermedia Secondary to Hydrocephalus.

    Science.gov (United States)

    El Damaty, Ahmed; Langner, Soenke; Schroeder, Henry W S

    2017-01-01

    We report a case of ruptured massa intermedia (MI) as a sequela of hydrocephalus. A single case report is presented describing the sequelae of tumor bed hematoma after a posterior fossa hemangioblastoma resection in which the patient bled 3 days after surgery, resulting in secondary hydrocephalus and subsequently dilatation of the third ventricle, which resulted in rupture of the MI. The patient was managed on emergency basis with an external ventricular drain then endoscopically with a third ventriculostomy and clot extraction. Absent MI is not uncommon in hydrocephalic patients, and it is assumed to be the result of rupture from acute dilatation of the third ventricle. Our case report proves this assumption and documents the presence and absence of the MI before and after developing hydrocephalus. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Linguine sign in musculoskeletal imaging: calf silicone implant rupture.

    Science.gov (United States)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E; Walker, Eric A

    2015-08-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition.

  3. Linguine sign in musculoskeletal imaging: calf silicone implant rupture

    International Nuclear Information System (INIS)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E.; Walker, Eric A.

    2015-01-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition. (orig.)

  4. Linguine sign in musculoskeletal imaging: calf silicone implant rupture

    Energy Technology Data Exchange (ETDEWEB)

    Duryea, Dennis; Petscavage-Thomas, Jonelle [Milton S. Hershey Medical Center, Department of Radiology, H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Frauenhoffer, Elizabeth E. [Milton S. Hershey Medical Center, Department of Pathology, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Walker, Eric A. [Milton S. Hershey Medical Center, Department of Radiology, H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Uniformed Services University of the Health Sciences, Department of Radiology and Nuclear Medicine, Bethesda, MD, 20814 (United States)

    2015-08-15

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition. (orig.)

  5. Dynamics of the rupture precursors for heterogeneous materials: application to vitreous polymers foams

    International Nuclear Information System (INIS)

    Deschanel, St.

    2005-12-01

    New physical approaches concerning the damage mechanisms consist to consider the rupture phenomenon as the critical point of a phase transition. Rupture can then result for some materials by a percolation of microcracks. This multi-crack implies the choice of heterogeneous materials. Mechanical tests on solid polymer foams have been carried out until rupture and have been coupled to the follow-up of the acoustic activity. The energies distributions reveal power laws independently of the material density, of the load mode or of the behaviour laws. On the other hand, the agreement with a power law of time periods seems to require a quasi constant stress on the most part of the test. The trend of the cumulated energy in the case of creep experiments seems to present a power law on a narrow period of time. On the other hand, for tensile tests, no power law has been observed. (O.M.)

  6. Investigations on the creep-rupture behaviour of the austenitic stainless steel AISI 316 NET

    International Nuclear Information System (INIS)

    Schirra, M.; Ritter, B.

    1988-12-01

    The report describes the creep-rupture tests carried out with a 17/13/2 CrNiMo-steel in the frame of the German-Spanish collaboration (KfK-CIEMAT). The material studied is the austenitic steel AISI 316(L) selected as potential first-wall material for NET (Next European Torus). The test programme on base material with a NET specified batch encompasses until now in the temperature range 500-750 0 C the rupture-time-range till 20 000 h. The results permit statements to the creep- and creep-rupture behaviour and ductility. Metallography examinations give information about fracture behaviour and demonstrate the complex precipitation happening. The results are compared with the literature and own test results from two batches of the Fast-Breeder-Program. (orig.) [de

  7. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  8. Testicular Rupture: A Tough Nut to Crack

    Directory of Open Access Journals (Sweden)

    Tyler L. Holliday

    2017-07-01

    Full Text Available Blunt scrotal injury represents a diagnostic dilemma for emergency physicians (EP. Consequently, point-of-care ultrasound (POCUS has emerged as a tool for early investigation of the acute scrotum in the emergency department. We describe a case where an EP used scrotal POCUS to immediately visualize the loss of testicular contour and underlying heterogeneous parenchyma to rapidly make the diagnosis of testicular rupture in a young male presenting with scrotal trauma. The use of POCUS in this case expedited therapy, likely improving the patient’s outcome. To our knowledge, this is the first detailed description of testicular rupture diagnosed with POCUS by an EP

  9. Spontaneous Achilles tendon rupture in alkaptonuria

    Directory of Open Access Journals (Sweden)

    Omar A. Alajoulin

    2015-12-01

    Full Text Available Alkaptonuria (AKU is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA. Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis, early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  10. Spontaneous Achilles tendon rupture in alkaptonuria.

    Science.gov (United States)

    Alajoulin, Omar A; Alsbou, Mohammed S; Ja'afreh, Somayya O; Kalbouneh, Heba M

    2015-12-01

    Alkaptonuria (AKU) is a rare inborn metabolic disease characterized by accumulation of homogentisic acid (HGA). Excretion of HGA in urine causes darkening of urine and its deposition in connective tissues causes dark pigmentation (ochronosis), early degeneration of articular cartilage, weakening of the tendons, and subsequent rupture. In this case report, we present a rare case of a patient presented with unilateral spontaneous rupture of Achilles tendon due to AKU. The patient developed most of the orthopedic manifestations of the disease earlier than typical presentations. Alkaptonuria patients should avoid strenuous exercises and foot straining especially in patients developing early orthopedic manifestations.

  11. Physiotherapy in patients with rupture LCA

    OpenAIRE

    Čížková, Karolína

    2012-01-01

    Author: Karolína Čížková Institution: Rehab clinic LF UK in Hradec Králové Topic of bachelor's thesis: Physiotherapy in patiens with rupture of ACL Supervisor: Mgr. Zuzana Hamarová Number of pages: 108 Number of annex: 11 Year of vindication 2012 Key words: ACL, knee, rupture of ACL, rehabilitation In general part of this bachelor's thesis is described anatomy, kinesiology and biomechanics of the knee joint, mostly anterior cruciate ligament. It contents causes of injury of anterior cruciate ...

  12. Proximal Hamstring Tendinosis and Partial Ruptures.

    Science.gov (United States)

    Startzman, Ashley N; Fowler, Oliver; Carreira, Dominic

    2017-07-01

    Proximal hamstring tendinosis and partial hamstring origin ruptures are painful conditions of the proximal thigh and hip that may occur in the acute, chronic, or acute on chronic setting. Few publications exist related to their diagnosis and management. This systematic review discusses the incidence, treatment, and prognosis of proximal hamstring tendinosis and partial hamstring ruptures. Conservative treatment measures include nonsteroidal anti-inflammatory drugs, physical therapy, rest, and ice. If these measures fail, platelet-rich plasma or shockwave therapy may be considered. When refractory to conservative management, these injuries may be treated with surgical debridement and hamstring reattachment. [Orthopedics. 2017; 40(4):e574-e582.]. Copyright 2017, SLACK Incorporated.

  13. [Development of Achilles tendon rupture in skiing].

    Science.gov (United States)

    Suckert, K; Benedetto, K P; Vogel, A

    1983-06-01

    This is an analysis of decline of rupture of the Achilles tendon in skiing while there is a steady increase of skiing injuries. Three groups, equipped with three different types of ski boots were observed once on a plane slope on the other hand on a bump track. The simultaneous size of angle of knee and ankle was measured by telemetry. The high plastic ski boot, which obstructs the ankle forward and lateral is apart from the rise of heel in the boot, the safety binding and the new skiing style the main reason for decline of rupture of the Achilles tendon in skiing.

  14. Heavy-ion-induced, gate-rupture in power MOSFETs

    International Nuclear Information System (INIS)

    Fischer, T.A.

    1987-01-01

    A new, heavy-ion-induced, burnout mechanism has been experimentally observed in power metal-oxide-semiconductor field-effect transistors (MOSFETs). This mechanism occurs when a heavy, charged particle passes through the gate oxide region of n- or p-channel devices having sufficient gate-to-source or gate-to-drain bias. The gate-rupture leads to significant permanent degradation of the device. A proposed failure mechanism is discussed and experimentally verified. In addition, the absolute immunity of p-channel devices to heavy-ion-induced, semiconductor burnout is demonstrated and discussed along with new, non-destructive, burnout testing methods

  15. Spontaneous esophageal rupture - Boerhaave's syndrome: Clinical symptoms and radiographic findings

    International Nuclear Information System (INIS)

    Gaa, J.; Deininger, H.K.

    1989-01-01

    Spontaneous transmural rupture of the esophagus (Boerhaave's syndrome) is a life-threatening emergency. Prompt diagnosis is essential to a better prognosis, successful operative outcome and patient survival. The chest roentgenogram and the contrast esophagograms to follow are the most helpful diagnostic tests. The clinical manifestations are variable and may be misleading and thus delay accurate recognition. In our case report the major clinical features and radiological signs of Boerhaave's syndrome are described. The pathogenesis, characteristic clinical symptoms and the signs and radiological evaluation are reviewed. (orig.) [de

  16. Rupture loop annex ion exchange RLAIX vault deactivation

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J.E.; Harris, D.L., Westinghouse Hanford

    1996-08-01

    This engineering report documents the deactivation, stabilization and final conditions of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located northwest of the 309 Building`s Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns, piping debris, and column liquid were removed from the vault, packaged and shipped for disposal. The vault walls and floor were decontaminated, and portions of the vault were painted to fix loose contamination. Process piping and drains were plugged, and the cover blocks and rain cover were installed. Upon closure,the vault was empty, stabilized, isolated.

  17. Open splenectomy for Varicella zoster induced spontaneous splenic rupture

    Directory of Open Access Journals (Sweden)

    Mark Christopher Sykes

    2018-01-01

    Conclusion: Atraumatic splenic rupture should be considered as an important differential in those presenting with abdominal pain and peritonism without a history of preceding trauma. Haematological and infectious diagnoses should be sought to identify causation for the splenic rupture.

  18. ADVANTAGES OF SURGICAL TREATMENT OF ACHILLES TENDON RUPTURE BY PERCUTANEOUS SUTURE AS OPPOSED TO NONSURGICAL TREATMENT

    Directory of Open Access Journals (Sweden)

    Goran Vidić

    2010-06-01

    Full Text Available The Achilles tendon is the strongest tendon in the body, and its rupture appears to be the most common injury of the tendomuscular apparatus. This type of injury is more frequent in sportsmen, especially those who play tennis, gymnastics, skiing, handball, football, basketball and athletics. Also, the ruptures are common in people who engage in sports activities for recreation. They appear more often in males, in proportion of 3:1. It appears reciprocally in 25- 30% of the cases. The rupture is easily diagnosed by means of clinical examination (Thompson's test and ultrasonography.The aim of the analysis was to point to the advantages of surgical treatment of a fresh Achilles tendon rupture as opposed to non-surgical treatment by plaster immobilization.The examination was performed on 35 patients, of which 16 (45,71% were treated operatively and 19 (54,29% were treated nonoperatively. The average age of the patients was 38.8 years, that is 37.1 for those treated operatively and 40.2 for those treated nonoperatively. Among the examinees, there were 29(82,86% men and 6 (17,14% women. The operative treatment method consisted of percutaneous suturing, whereas the nonoperative treatment involved the circular above the knee plaster immobilization. All operatively treated patients underwent the surgical treatment in the first 48 hours from the time when the injury had occured. Anesthesia was local and infiltrative.The obtained results showed that there were no unhealed ruptures or re-ruptures. In the group of patients who did not undergo the surgery, there was 1 re-rupture and 1 unhealed rupture, after which the surgical treatment had to be performed in both cases. In the group of operated patients there were no infections, however, 1 thromboembolism occured. Recovery of muscular strenght of the tendon and the realization of the full range of movement required less time in the operated patients. The ultrasonographic findings in the operated patients

  19. Anisotropic stress rupture properties of the nickel-base single crystal superalloy SRR99

    International Nuclear Information System (INIS)

    Han, G.M.; Yu, J.J.; Sun, Y.L.; Sun, X.F.; Hu, Z.Q.

    2010-01-01

    The influence of orientation on the stress rupture properties of a single crystal superalloy SRR99 was investigated at temperatures of 760 and 1040 deg. C. It is found that the creep anisotropic behaviour is pronounced at the lower temperature of 760 deg. C and the stress rupture life ranks in the order [0 0 1] > [1 1 1] > [0 1 1]. Despite the anisotropy of stress rupture life is evidently reduced at the higher temperature, the [1 1 1] orientation exhibits the longest life. At 760 deg. C, EBSD (electron back scattered diffraction) was adopted to measure the lattice rotation and the deduced results indicate that the dominant slip systems are {1 1 1} during stress rupture test. At 1040 deg. C, the ranking order of the stress rupture life is [1 1 1] > [0 0 1] > [0 1 1] and the single crystal close to [0 1 1] orientation still shows the poorest life. In the [0 0 1] and [1 1 1] samples, regular γ' raft structure is formed compared with [0 1 1] samples. Further observations made by TEM investigations reveal the underlying deformation mechanisms for crystals with orientations near [0 0 1], [0 1 1] and [1 1 1] under two test conditions.

  20. Amnioinfusion for preterm rupture of membranes.

    Science.gov (United States)

    Hofmeyr, G J

    2000-01-01

    Preterm rupture of membranes places a fetus at risk of cord compression and amnionitis. Amnioinfusion aims to prevent or relieve umbilical cord compression by infusing a solution into the uterine cavity. The objective of this review was to assess the effects of amnioinfusion for preterm rupture of membranes on maternal and perinatal outcomes. The Cochrane Pregnancy and Childbirth Group trials register and the Cochrane Controlled Trials Register were searched. Randomised trials of amnioinfusion compared to no amnioinfusion in women with preterm rupture of membranes. Eligibility and trial quality were assessed by the reviewer. One trial of 66 women was included. It had some methodological flaws. No significant differences between amnioinfusion and no amnioinfusion were detected for caesarean section (relative risk 0.32, 95% confidence interval 0.07 to 1.40); low Apgar scores (relative risk 0.28, 95% confidence interval 0.03 to 2.33) or neonatal death (relative risk 0.55, 95% confidence interval 0.05 to 5.77). In the amnioinfusion group, the number of severe fetal heart rate decelerations per hour during the first stage of labour were reduced (weighted mean difference -1.20, 95% confidence interval -1.83 to -0.57). These outcomes are consistent with those found in the Cochrane review on amnioinfusion for cord compression. There is not enough evidence concerning the use of amnioinfusion for preterm rupture of membranes.

  1. The reactor Phenix - cartridge rupture detection

    International Nuclear Information System (INIS)

    Graftieaux, J.

    1967-01-01

    This report defines the role of cartridge rupture detection in the reactor Phenix. It gives the possible methods, their probable performances, their advantages and disadvantages. The final form of the installation will be determined mainly by the degree of safety required, by the technical possibilities of the reactor design and by the operational flexibility wanted. (author) [fr

  2. Traumatic rupture of the diaphragm: CT findings

    International Nuclear Information System (INIS)

    Cho, Sung Tae; Kim, Sung Jin; Cha, Sang Hoon; Park, Kil Sun; Kim, Jin Hee; Yim, Se Hwan

    1995-01-01

    The aim of this study was to assess the clinical utility of the known CT signs of the traumatic rupture of the diaphragm. CT scans and chest radiographs were retrospectively reviewed in 13 patients who had diaphragmatic rupture confirmed by surgery. On chest radiographs the elevation of the diaphragm was evaluated. On CT, 1) discontinuity of the diaphragm, 2) lack of depiction of the diaphragm surrounding the herniated intraabdominal organs (absent diaphragm sign), and 3) fat seen lateral to the diaphragm (fat sign) were evaluated. Chest radiographs showed the elevation of the diaphragm in 11 patients (85%). CT scan showed absent diaphragm sign in 11 patients (85%), discontinuity of the diaphragm in 8 (62%), and fat sign in 7 (54%). All of 12 patients who had the left diaphragmatic rupture had one or more of the above findings. Discontinuity of the diaphragm, absent diaphragm sign, and fat sign may be helpful CT findings in the diagnosis of the traumatic rupture of the left diaphragm

  3. Rupture of the tuberosity of the tibia

    International Nuclear Information System (INIS)

    Schild, H.; Schwarzkopf, W.

    1981-01-01

    Ruptures of the tuberosity of the tibia occur particularly in male adolescents, although on the whole they represent a rare type of injury. The article discusses classification into different types according to Watson-Jones as well as exemplary models, traumatology, clinic and therapy. (orig.) [de

  4. Ruptured Cervical Aneurysm with Neurofibromatosis | Smith | South ...

    African Journals Online (AJOL)

    A case is presented of spontaneous rupture of an aneurysm of a lateral branch of the right thyrocervical trunk in a patient suffering from diffuse neurofibromatosis. The operative findings are reported. S. Afr. Med. J., 48, 945 (1974). Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT ...

  5. The electrocardiogram in traumatic right atrial rupture

    NARCIS (Netherlands)

    van Veldhuisen, DJ; van den Berg, MP

    1999-01-01

    We:report the case of a previously healthy 20-year-old man who had a traumatic rupture of the right atrium. On admission an electrocardiogram (ECG) was recorded which is highly remarkable and, retrospectively, suggestive for the diagnosis. The patient died soon after the EGG, and the diagnosis was

  6. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  7. Bilateral synchronous rupture of the quadriceps tendon.

    LENUS (Irish Health Repository)

    Ellanti, P

    2012-09-01

    Bilateral simultaneous rupture of the quadriceps tendon is a rare entity. They are often associated with degenerative changes of the tendons and predisposing conditions such as diabetes or excessive steroid use. They most commonly tend to occur in patients of 40 years of age or older.

  8. Rupture of the neck in nuclear fission

    International Nuclear Information System (INIS)

    Davies, K.T.R.; Managan, R.A.; Nix, J.R.; Sierk, A.J.

    1977-01-01

    We introduce a degree of freedom to describe the rupture of the neck in nuclear fission and calculate the point at which the neck ruptures as the nucleus descends dynamically from its fission saddle point. This is done by mentally slicing the system into two portions at its minimum neck radius and calculating the force required to separate the two portions while keeping their shapes fixed. This force is obtained by differentiating with respect to separation the sum of the Coulomb and nuclear interaction energies between the two portions. For nuclei throughout the Periodic Table we calculate this force along dynamical paths leading from the fission saddle point. The force is initially attractive but becomes repulsive when the neck reaches a critical size. For actinide nuclei the neck radius at which rupture occurs is about 2 fm. This increases the calculated translational kinetic energy of the fission fragments at infinity relative to that calculated for scission occurring at zero neck radius. With the effect of neck rupture taken into account, we calculate and compare with experimental results fission-fragment kinetic energies for two types of nuclear dissipation: ordinary two-body viscosity and one-body dissipation

  9. Creep rupture behavior of candidate materials for nuclear process heat applications

    International Nuclear Information System (INIS)

    Schubert, F.; te Heesen, E.; Bruch, U.; Cook, R.; Diehl, H.; Ennis, P.J.; Jakobeit, W.; Penkalla, H.J.; Ullrich, G.

    1984-01-01

    Creep and stress rupture properties are determined for the candidate materials to be used in hightemperature gas-cooled reactor (HTGR) components. The materials and test methods are briefly described based on experimental results of test durations of about20000 h. The medium creep strengths of the alloys Inconel-617, Hastelloy-X, Nimonic-86, Hastelloy-S, Manaurite-36X, IN-519, and Incoloy-800H are compared showing that Inconel-617 has the best creep rupture properties in the temperature range above 800 0 C. The rupture time of welded joints is in the lower range of the scatterband of the parent metal. The properties determined in different simulated HTGR atmospheres are within the scatterband of the properties obtained in air. Extrapolation methods are discussed and a modified minimum commitment method is favored

  10. On the unit rupture work of metals and alloys

    International Nuclear Information System (INIS)

    Verkhoturov, A.D.; Kovalenko, V.S.; Dyatel, V.P.

    1980-01-01

    Studied is the effect of the nature of the treated material treatment regimes on their unit rupture work at laser treatment in the regime of quasistationary evaporation. It is shown that the unit rupture work changes its values depending on the treatment regimes, coincidences between experimental and calculation values of unit rupture work are not being observed, especially for refractory metals of the 6th group and for solid alloys. Established are optimum regimes for determination of stable values of unit rupture work

  11. Computing broadband accelerograms using kinematic rupture modeling

    International Nuclear Information System (INIS)

    Ruiz Paredes, J.A.

    2007-05-01

    In order to make the broadband kinematic rupture modeling more realistic with respect to dynamic modeling, physical constraints are added to the rupture parameters. To improve the slip velocity function (SVF) modeling, an evolution of the k -2 source model is proposed, which consists to decompose the slip as a sum of sub-events by band of k. This model yields to SVF close to the solution proposed by Kostrov for a crack, while preserving the spectral characteristics of the radiated wave field, i.e. a w 2 model with spectral amplitudes at high frequency scaled to the coefficient of directivity C d . To better control the directivity effects, a composite source description is combined with a scaling law defining the extent of the nucleation area for each sub-event. The resulting model allows to reduce the apparent coefficient of directivity to a fraction of C d , as well as to reproduce the standard deviation of the new empirical attenuation relationships proposed for Japan. To make source models more realistic, a variable rupture velocity in agreement with the physics of the rupture must be considered. The followed approach that is based on an analytical relation between the fracture energy, the slip and the rupture velocity, leads to higher values of the peak ground acceleration in the vicinity of the fault. Finally, to better account for the interaction of the wave field with the geological medium, a semi-empirical methodology is developed combining a composite source model with empirical Green functions, and is applied to the Yamaguchi, M w 5.9 earthquake. The modeled synthetics reproduce satisfactorily well the observed main characteristics of ground motions. (author)

  12. Ruptured liver abscess: Analysis of 50 cases

    Directory of Open Access Journals (Sweden)

    Mohit Bhatia

    2017-01-01

    Full Text Available Background: Liver abscess (pyogenic and amebic is frequently encountered clinical condition; however, it can result in lethal outcome if there is a delay in diagnosis and treatment. Despite modalities to diagnose the condition early, still ruptured liver abscess presents with a common cause of acute abdomen in surgical emergency. In developing countries, ruptured liver abscess is a common cause of mortality. For contained abscess, nonsurgical options are considered; however, for ruptured liver abscess, surgical intervention is considered necessary. Materials and Methods: This was a retrospective study carried in Safdarjung hospital, New Delhi, between 2015 and 2016. All patients with ruptured liver abscess (clear signs of peritonitis were included in this study, and those patients having other causes of peritonitis were excluded. A preformed protocol for management was followed for all the patients, and various parameters contributing to the illness and its prognosis were evaluated and assessed. Results: Out of the fifty patients assessed, male patients were mainly affected (86%. The most affected age group was 31–40 years (64% followed by 41–50 years (22%. Right hypochondrium pain was the most common presenting complaint. Nine patients (18% had presented with signs of toxemia. Only right lobe of the liver was affected the most in 44 patients (88%. Escherichia coli was the most common organism isolated in our study in 19 patients (38%. A total of 19 patients (38% had diabetes in our study and total of 13 patients had mortality in our study. Conclusion: Ruptured liver abscess most commonly involves the right lobe of the liver. Males are affected far higher than the females; probable cause believed to be higher alcohol consumption. Most common affected age group falls between 30 and 60 years of age. If prompt treatment is started in time, mortality involved with it is evitable.

  13. Ruptured uterus in Kano, Nigeria - study of risk factors | Omole ...

    African Journals Online (AJOL)

    This is a comparative prospective study of the risk factors for ruptured uterus in Aminu Kano Teaching Hospital, Kano, Nigeria, between 1st January 2000 and 31st December 2005. Forty six women with ruptured uterus (cases) were compared with two hundred and thirty women who delivered without ruptured uterus ...

  14. Ruptured Uterus At Afikpo, Southeast Nigeria. | Eze | Ebonyi Medical ...

    African Journals Online (AJOL)

    Context: Ruptured uterus is an obstetric catastrophe associated with high maternal and perinatal mortality. Objectives: To determine the incidence, causes, management and fetomaternal outcomes of ruptured uterus in Afikpo, Southeast Nigeria. Methods: Delivery records, theatre registers and case notes of all ruptured ...

  15. Radionuclide diagnosis of splenic rupture in infectious mononucleosis

    International Nuclear Information System (INIS)

    Vezina, W.C.; Nicholson, R.L.; Cohen, P.; Chamberlain, M.J.

    1984-01-01

    Spontaneous splenic rupture is a rare but serious complication of infectious mononucleosis. Although radionuclide spleen imaging is a well accepted method for diagnosis of traumatic rupture, interpretation can be difficult in the setting of mononucleosis, as tears may be ill-defined and diagnosis hampered by inhomogeneous splenic uptake. Four proven cases of spontaneous rupture are presented, three of which illustrate these diagnostic problems

  16. Delivery of placenta before baby in ruptured uterus | Ameh | Annals ...

    African Journals Online (AJOL)

    An unusual case of ruptured uterus characterized by spontaneous delivery of the placenta while the foetus is retained in the abdomen is presented. The management and prevention of ruptured uterus in Sub- Saharan Africa is discussed. Key Words: Delivery of placenta, ruptured uterus. Annals of African Medicine Vol.3(3) ...

  17. Ruptured rectal duplication with urogenital abnormality: Unusual presentation

    Directory of Open Access Journals (Sweden)

    Shailesh Solanki

    2015-01-01

    Full Text Available Rectal duplication (RD accounts for 5% of alimentary tract duplication. A varied presentation and associated anomalies have been described in the literature. Antenatal rupture of the RD is very rare. We present an unusual case of a ruptured RD associated with urogenital abnormalities in newborn male. We are discussing diagnosis, embryology, management and literature review of ruptured RD.

  18. Ruptured rectal duplication with urogenital abnormality: Unusual presentation.

    Science.gov (United States)

    Solanki, Shailesh; Babu, M Narendra; Jadhav, Vinay; Shankar, Gowri; Santhanakrishnan, Ramesh

    2015-01-01

    Rectal duplication (RD) accounts for 5% of alimentary tract duplication. A varied presentation and associated anomalies have been described in the literature. Antenatal rupture of the RD is very rare. We present an unusual case of a ruptured RD associated with urogenital abnormalities in newborn male. We are discussing diagnosis, embryology, management and literature review of ruptured RD.

  19. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  20. Challenging Friesian horse diseases : aortic rupture and megaesophagus

    NARCIS (Netherlands)

    Ploeg, M.

    2015-01-01

    Aortic rupture is quite rare in Warmblood horses and is best known as an acute and fatal rupture of the aortic root in older breeding stallions. It has now become clear that aortic rupture, which is diagnosed around an age of 4 years, is more frequent in the Friesian breed than in others. The high

  1. The Inclusion of Arbitrary Load Histories in the Strength Decay Model for Stress Rupture

    Science.gov (United States)

    Reeder, James R.

    2014-01-01

    Stress rupture is a failure mechanism where failures can occur after a period of time, even though the material has seen no increase in load. Carbon/epoxy composite materials have demonstrated the stress rupture failure mechanism. In a previous work, a model was proposed for stress rupture of composite overwrap pressure vessels (COPVs) and similar composite structures based on strength degradation. However, the original model was limited to constant load periods (holds) at constant load. The model was expanded in this paper to address arbitrary loading histories and specifically the inclusions of ramp loadings up to holds and back down. The broadening of the model allows for failures on loading to be treated as any other failure that may occur during testing instead of having to be treated as a special case. The inclusion of ramps can also influence the length of the "safe period" following proof loading that was previously predicted by the model. No stress rupture failures are predicted in a safe period because time is required for strength to decay from above the proof level to the lower level of loading. Although the model can predict failures during the ramp periods, no closed-form solution for the failure times could be derived. Therefore, two suggested solution techniques were proposed. Finally, the model was used to design an experiment that could detect the difference between the strength decay model and a commonly used model for stress rupture. Although these types of models are necessary to help guide experiments for stress rupture, only experimental evidence will determine how well the model may predict actual material response. If the model can be shown to be accurate, current proof loading requirements may result in predicted safe periods as long as 10(13) years. COPVs design requirements for stress rupture may then be relaxed, allowing more efficient designs, while still maintaining an acceptable level of safety.

  2. Study of the consequences of the rupture of a pressure tube in the tank of a gas-cooled, heavy-water moderated reactor

    International Nuclear Information System (INIS)

    Hareux, F.; Roche, R.; Vrillon, B.

    1964-01-01

    Bursting of a pressure tube in the tank of a heavy water moderated-gas cooled reactor is an accident which has been studied experimentally about EL-4. A first test (scale 1) having shown that the burst of a tube does not cause the rupture of adjacent tubes, tests on the tank resistance have been undertaken with a very reduced scale model (1 to 10). It has been found that the tank can endure many bursts of tube without any important deformation. Transient pressure in the tank is an oscillatory weakened wave, the maximum of which (pressure peak) has been the object of a particular experimental study. It appears that the most important parameters which affect the pressure peak are; the pressure of the gas included in the bursting pressure tube, the volume of this gas, the mass of air included in the tank and the nature of the gas. A general method to calculate the pressure peak value in reactor tanks has been elaborated by direct application of experimental data. (authors) [fr

  3. Correlation between atmospheric pressure changes and abdominal aortic aneurysm rupture: results of a single-center study.

    Science.gov (United States)

    Molacek, Jiri; Treska, Vladislav; Kasik, Miroslav; Houdek, Karel; Baxa, Jan

    2013-09-01

    There is much interest in all factors that influence the etiopathogenesis of abdominal aortic aneurysm (AAA) rupture. Apart from the well-established factors such as arterial hypertension, smoking, age, and genetic predisposition, less common factors that may play a role in the mechanism of the rupture are the subject of much discussion. These include atmospheric conditions, temperature, and atmospheric pressure. We conducted this study to investigate the effects of the absolute value of atmospheric pressure and its changes on the frequency of AAA rupture. We retrospectively examined 54 patients who underwent treatment for a ruptured AAA at the Clinic of Surgery in the University Hospital in Pilsen between 1 January 2005 and 31 December 2009. We collected data on the atmospheric pressure in this period from the Czech Hydrometeorological Institute in Pilsen. We did not find a significant difference in atmospheric pressure values between the days when the rupture occurred versus the other days (p atmospheric pressure during the 48 h preceding the rupture (Student's test p atmospheric pressure in that month. These findings suggest that atmospheric pressure and its changes do not affect the pathogenesis of AAA rupture.

  4. Creep-rupture correlations for type 304 stainless steel heat 9T2796

    International Nuclear Information System (INIS)

    Swindeman, R.W.

    1975-01-01

    Creep-rupture data are presented for a reference heat of type 304 stainless steel tested at temperatures between 482 and 816 0 C (900-1500 0 F) and for times to 10,000 hr. The ability of several popular time-temperature parameters to correlate the rupture data is examined, and it shows that the Orr-Sherby-Dorn parameter provides a slightly better fit to the data than the Larson-Miller, Manson-Haferd, and Manson-Succop parameters. An alternative model is developed, based on the Barrett-Ardell-Sherby parameter, which makes use of modulus-compensated true stresses. These stresses are approximated on the basis of the strain about halfway through the test. Although the parameter does not fit the data quite as well as the Orr-Sherby-Dorn parameter, the activation energy associated with the parameter approaches the value expected for solute element diffusion in stainless steel. In the very high-stress region the master curve generated by the parameter is used to examine the interface between the results of tensile tests, described in terms of the Voce equation, and the creep-rupture tests. The tensile data can be correlated with the Barrett-Ardel-Sherby parameter when the tensile testing conditions are such that rupture is initiated by grain boundary failures

  5. Safety design guide for pipe rupture protection for CANDU 9

    International Nuclear Information System (INIS)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; A. C. D. Wright

    1996-03-01

    This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new

  6. Creep rupture strength of activated-TIG welded 316L(N) stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Sakthivel, T., E-mail: tsakthivel@igcar.gov.in [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Vasudevan, M.; Laha, K.; Parameswaran, P.; Chandravathi, K.S.; Mathew, M.D.; Bhaduri, A.K. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2011-06-01

    316L(N) stainless steel plates were joined using activated-tungsten inert gas (A-TIG) welding and conventional TIG welding process. Creep rupture behavior of 316L(N) base metal, and weld joints made by A-TIG and conventional TIG welding process were investigated at 923 K over a stress range of 160-280 MPa. Creep test results showed that the enhancement in creep rupture strength of weld joint fabricated by A-TIG welding process over conventional TIG welding process. Both the weld joints fractured in the weld metal. Microstructural observation showed lower {delta}-ferrite content, alignment of columnar grain with {delta}-ferrite along applied stress direction and less strength disparity between columnar and equiaxed grains of weld metal in A-TIG joint than in MP-TIG joint. These had been attributed to initiate less creep cavitation in weld metal of A-TIG joint leading to improvement in creep rupture strength.

  7. Creep rupture strength of activated-TIG welded 316L(N) stainless steel

    International Nuclear Information System (INIS)

    Sakthivel, T.; Vasudevan, M.; Laha, K.; Parameswaran, P.; Chandravathi, K.S.; Mathew, M.D.; Bhaduri, A.K.

    2011-01-01

    316L(N) stainless steel plates were joined using activated-tungsten inert gas (A-TIG) welding and conventional TIG welding process. Creep rupture behavior of 316L(N) base metal, and weld joints made by A-TIG and conventional TIG welding process were investigated at 923 K over a stress range of 160-280 MPa. Creep test results showed that the enhancement in creep rupture strength of weld joint fabricated by A-TIG welding process over conventional TIG welding process. Both the weld joints fractured in the weld metal. Microstructural observation showed lower δ-ferrite content, alignment of columnar grain with δ-ferrite along applied stress direction and less strength disparity between columnar and equiaxed grains of weld metal in A-TIG joint than in MP-TIG joint. These had been attributed to initiate less creep cavitation in weld metal of A-TIG joint leading to improvement in creep rupture strength.

  8. Creep rupture strength of activated-TIG welded 316L(N) stainless steel

    Science.gov (United States)

    Sakthivel, T.; Vasudevan, M.; Laha, K.; Parameswaran, P.; Chandravathi, K. S.; Mathew, M. D.; Bhaduri, A. K.

    2011-06-01

    316L(N) stainless steel plates were joined using activated-tungsten inert gas (A-TIG) welding and conventional TIG welding process. Creep rupture behavior of 316L(N) base metal, and weld joints made by A-TIG and conventional TIG welding process were investigated at 923 K over a stress range of 160-280 MPa. Creep test results showed that the enhancement in creep rupture strength of weld joint fabricated by A-TIG welding process over conventional TIG welding process. Both the weld joints fractured in the weld metal. Microstructural observation showed lower δ-ferrite content, alignment of columnar grain with δ-ferrite along applied stress direction and less strength disparity between columnar and equiaxed grains of weld metal in A-TIG joint than in MP-TIG joint. These had been attributed to initiate less creep cavitation in weld metal of A-TIG joint leading to improvement in creep rupture strength.

  9. Elevation of serum CA 125 and D-dimer levels associated with rupture of ovarian endometrioma.

    Science.gov (United States)

    Uharcek, P; Mlyncek, M; Ravinger, J

    2007-01-01

    Patients with endometriosis rarely have a serum CA 125 concentration >100 IU/mL. A raised plasma level of D-dimer indicates active fibrinolysis, either secondary to clot formation or primarily activated. This condition is seldom diagnosed in patients with endometriosis. A 53-year-old woman was referred to our institution for acute abdominal pain. Laparoscopic surgery revealed a large ovarian cyst with rupture on the left side. Preoperative laboratory tests detected high serum CA 125 and D-dimer levels. Adnexectomy was performed, resulting in a sharp decrease in serum CA 125 and D-dimer concentration. We describe the clinical course of the patient. Rupture of a large ovarian endometrioma can lead to a high serum concentration of CA 125, a condition which, in addition to the detected pelvic mass, may mimic a malignant process. The increased D-dimer plasma level indicated that a ruptured endometriotic cyst can induce coagulation reactions.

  10. Use of ICD-10 codes to monitor uterine rupture

    DEFF Research Database (Denmark)

    Thisted, Dorthe L A; Mortensen, Laust Hvas; Hvidman, Lone

    2014-01-01

    OBJECTIVES: Uterine rupture is a rare but severe complication in pregnancies after a previous cesarean section. In Denmark, the monitoring of uterine rupture is based on reporting of relevant diagnostic codes to the Danish Medical Birth Registry (MBR). The aim of our study was to examine the vali......OBJECTIVES: Uterine rupture is a rare but severe complication in pregnancies after a previous cesarean section. In Denmark, the monitoring of uterine rupture is based on reporting of relevant diagnostic codes to the Danish Medical Birth Registry (MBR). The aim of our study was to examine...... uterine ruptures, the sensitivity and specificity of the codes for uterine rupture were 83.8% and 99.1%, respectively. CONCLUSION: During the study period the monitoring of uterine rupture in the MBR was inadequate....

  11. Influence of Evaporation on Soap Film Rupture.

    Science.gov (United States)

    Champougny, Lorène; Miguet, Jonas; Henaff, Robin; Restagno, Frédéric; Boulogne, François; Rio, Emmanuelle

    2018-03-13

    Although soap films are prone to evaporate due to their large surface to volume ratio, the effect of evaporation on macroscopic film features has often been disregarded in the literature. In this work, we experimentally investigate the influence of environmental humidity on soap film stability. An original experiment allows to measure both the maximum length of a film pulled at constant velocity and its thinning dynamics in a controlled atmosphere for various values of the relative humidity [Formula: see text]. At first order, the environmental humidity seems to have almost no impact on most of the film thinning dynamics. However, we find that the film length at rupture increases continuously with [Formula: see text]. To rationalize our observations, we propose that film bursting occurs when the thinning due to evaporation becomes comparable to the thinning due to liquid drainage. This rupture criterion turns out to be in reasonable agreement with an estimation of the evaporation rate in our experiment.

  12. Failure analysis on a ruptured petrochemical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Harun, Mohd [Industrial Technology Division, Malaysian Nuclear Agency, Ministry of Science, Technology and Innovation Malaysia, Bangi, Kajang, Selangor (Malaysia); Shamsudin, Shaiful Rizam; Kamardin, A. [Univ. Malaysia Perlis, Jejawi, Arau (Malaysia). School of Materials Engineering

    2010-08-15

    The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

  13. Rupture of major vessels after radiation

    International Nuclear Information System (INIS)

    Fajardo, L.F.; Lee, A.

    1975-01-01

    Rupture of irradiated large vessels is an uncommon complication which tends to occur in carotid, aorta, and femoral arteries, in decreasing order of incidence. It particularly affects men subjected to surgery and radiotherapy for epidermoid carcinomas in oropharynx, esophagus, or genitalia. Contrary to some opinion, radiation is not the most significant cause; this spontaneous arterial rupture can occur without radiation. The perforation is not associated with tumor invasion of arterial wall, as has been claimed. Surgical complications, especially necrosis of skin flaps, infection, and fistulas are most important etiologically. Only 2 of the 11 instances that we describe appear to have been caused mainly by radiation. The perforation is usually fatal, but several patients, including 3 of our series (2 carotid, 1 femoral), have been saved by hospital personnel aware of this complication. To prevent it, prolonged exposure or infection of arteries, whether irradiated or not, should be avoided. (auth)

  14. [Traumatic rupture of a horseshoe kidney].

    Science.gov (United States)

    Pascual Samaniego, M; Bravo Fernández, I; Ruiz Serrano, M; Ramos Martín, J A; Lázaro Méndez, J; García González, A

    2006-04-01

    One-third to one-half of all patients with horseshoe kidney are asymptomatic and the condition is found incidentally. This congenital renal anomaly has shown as a predisponent condition for renal injury in blunt abdominal trauma, but often the degree of injury has a nonoperative therapy. Horseshoe kidney rupture is an exceptional pathology that require a complete diagnostic study to make an adequate management when surgical therapy is indicated. We present a fifteen-year-old male with previously unsuspected horseshoe kidney that suffered an atypical right upper-pole and mesorrenal kidney rupture after low-velocity-impact blunt abdominal trauma. A correct presurgical diagnose let a deferred surgical approach with right lower pole and horseshoe renal isthmus preservation. The trauma conditions, an excesive clinic manifestation, a clinical investigation about known congenital simultaneous anomallies and typical radiological signs, can suggest this infrequent patology. Computed tomography provides the best radiological information.

  15. Steam generator tube rupture (SGTR) scenarios

    International Nuclear Information System (INIS)

    Auvinen, A.; Jokiniemi, J.K.; Laehde, A.; Routamo, T.; Lundstroem, P.; Tuomisto, H.; Dienstbier, J.; Guentay, S.; Suckow, D.; Dehbi, A.; Slootman, M.; Herranz, L.; Peyres, V.; Polo, J.

    2005-01-01

    The steam generator tube rupture (SGTR) scenarios project was carried out in the EU 5th framework programme in the field of nuclear safety during years 2000-2002. The first objective of the project was to generate a comprehensive database on fission product retention in a steam generator. The second objective was to verify and develop predictive models to support accident management interventions in steam generator tube rupture sequences, which either directly lead to severe accident conditions or are induced by other sequences leading to severe accidents. The models developed for fission product retention were to be included in severe accident codes. In addition, it was shown that existing models for turbulent deposition, which is the dominating deposition mechanism in dry conditions and at high flow rates, contain large uncertainties. The results of the project are applicable to various pressurised water reactors, including vertical steam generators (western PWR) and horizontal steam generators (VVER)

  16. Tensile Stress Rupture Behavior of a Woven Ceramic Matrix Composite in Humid Environments at Intermediate Temperature

    National Research Council Canada - National Science Library

    LaRochelle, Kevin J

    2005-01-01

    Stress rupture tests on the Sylramic(TM) fiber with an in-situ layer of boron nitride, boron nitride interphase, and SiC matrix ceramic matrix composite were performed at 550 degrees C and 750 degrees C with 0.0, 0.2...

  17. Clinical diagnosis of an anterior cruciate ligament rupture : A meta-analysis

    NARCIS (Netherlands)

    Benjammse, A; Gokeler, A; van der Schans, CP

    Study Design: Meta-analysis. Objectives: To define the accuracy of clinical tests for assessing anterior cruciate ligament (ACL) ruptures. Background: The cruciate ligaments, and especially the ACL, are among the most commonly injured structures of the knee. Given the increasing injury prevalence,

  18. Computed tomography in ruptured intracranial aneurysm

    International Nuclear Information System (INIS)

    Suzuki, Michiyasu; Ogawa, Akira; Sakurai, Yoshiharu; Komatsu, Shinro; Suzuki, Jiro.

    1983-01-01

    The differences between initial bleeding and rebleeding due to ruptured intracranial aneurysm was investigated by CT. The study included 120 cases of ruptured cerebral aneurysm; 71 cases had only one bleeding and 49 cases had rebleeding. All the cases underwent CT examinations within 2 weeks following bleeding. Subarachnoid hemorrhages were classified into three groups according to the CT findings: Diffuse high type-high density areas in the entire basal cistern; Localized high type-high density area in a restricted part of the basal cistern; and Iso or Low type-no high density areas in the basal cistern. CT scans done within 24 hours following initial bleeding showed Diffuse high type in 96% of the cases and Localized high type in 4%. On the other hand, in rebleeding cases, Diffuse high type was 50%, Localized high type 25% and Iso or Low type 25%. In rebleeding cases within three days following initial bleeding, Diffuse high type was 90% and Iso or Low type 10%. However, between day 4 and day 14, Diffuse high type was 14%, Localized high type 42% and Iso or Low type 42%. After day 15, Diffuse high type was 36%, Localized type 36% and Iso or Low type 28%. Intracerebral hematoma and/or ventricular hemorrhage secondary to ruptured aneurysms were also investigated. Following initial bleeding, 18% of cases showed intracerebral and/or ventricular hemorrhage, however, the incidence increased up to 59% in rebleeding cases. These observations indicate that the subarachnoid hemorrhage due to re-ruptured aneurysm tends to be more localized than in initial bleeding cases and that intracerebral and/or ventricular hemorrhage seems more frequent in rebleeding cases. (author)

  19. Spontaneous bladder rupture in acute alcohol intoxication

    Directory of Open Access Journals (Sweden)

    Bahjat Barakat

    2014-03-01

    Full Text Available Spontaneous bladder rupture is a rare condition that can be followed by an acute alcohol intoxication and can be associated with significant morbidity and mortality. We report a case diagnosed in a alcoholic young male who was admitted to our emergency room for epigastric pain. The case demonstrates the difficulties with diagnosis and the need for physicians who work in an emergency room to be aware of this condition.

  20. RESEARCH ON REDUCING PREMATURITY RUPTURE OF MEMBRANE

    OpenAIRE

    Maria URSACHI (BOLOTA); Emil ANTON; Sorana Caterina ANTON

    2016-01-01

    The membranes surrounding the amniotic cavity are composed from amnion and chorion, tightly adherent layers which are composed of several cell types, including epithelial cells, trophoblasts cells and mesenchyme cells, embedded in a collagenous matrix. They retain amniotic fluid, secret substances into the amniotic fluid, as well as to the uterus and protect the fetus against upward infections from urogenital tract. Normally, the membranes it breaks during labor. Premature rupture of the amn...

  1. Case of a spontaneously ruptured epidermoid cyst

    Energy Technology Data Exchange (ETDEWEB)

    Shiroyama, Y; Saiki, M; Ueda, H; Katayama, S; Mitani, T

    1987-02-01

    Intracranial fat-containing congenital tumors are characterized by negative absorption values on CT. We hereby report a case of an epidermoid cyst with subarachnoid free fats diagnosed preoperatively by CT. A 21-year-old female was admitted to our hospital because of continuous mild headache and nausea. At the time of admission, the results of her physical and neurological examinations were normal. CT, however, demonstrated multiple subarachnoid low-density spots and a suprasellar low-density area with high-density spots. In addition, there were negative absorption values (-12 -- -77), suggesting free fats. A spontaneously ruptured epidermoid or dermoid cyst was diagnosed on the basis of these findings. At surgery, a suprasellar tumor containing a yellowish, cheese-like material was confirmed. The patient made an uneventful recovery and was discharged 14 days after surgery. There have been several published reports of CT appearances of intracranial fat-containing tumors. However, spontaneously ruptured cases diagnosed by CT are rare. CT was found to be useful for the diagnosis of spontaneously ruptured cases of fat-containing tumors.

  2. Radiological evaluation of sinus valsalva rupture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yul; Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    We obtained the following results by reviewing the radiographic findings of 15 cases of Sinus valsalva rupture who were diagnosed surgically at Seoul National University Hospital since 1979. 1. Among distribution was from 15 years to 40 years with the mean age of 24 years. Among the 15 cases, 9 cases were male and 7 were female. 2. Ruptured sinus is right coronary sinus projecting to right ventricle in all 15 cases. Combined diseases are ventricular septal defect in 12 cases, Aortic Valvular heart disease in 4 cases, and narrowing of right ventricular outflow tract in 2 cases, and aneurysmal dilatation of right pulmonary artery in 1 cases. 3. Chest X-ray findings were that of left to right shunt, i.e, cardiomegaly, increased pulmonary vascularity but were normal in 3 cases. 4. Aortography showed sequential leakage of dye from right coronary sinus to right ventricle and finally to pulmonary artery in 9 cases, and in 9 cases of them the leakage is directly to right ventricular outflow tract without filling of sinus portion of the ventricle., i.e., type I. 5. The leakage was well shown in left ventricular diastolic phase and not shown in systolic phase. 6. Ventricular septal defects were not detected definitely in spite of taking left ventriculography. 7. Cine angiography is essential for detecting accurate site, degree and direction of sinus valsalva rupture and other associated cardiac abnormality.

  3. Radiological evaluation of sinus valsalva rupture

    International Nuclear Information System (INIS)

    Lee, Yul; Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung

    1984-01-01

    We obtained the following results by reviewing the radiographic findings of 15 cases of Sinus valsalva rupture who were diagnosed surgically at Seoul National University Hospital since 1979. 1. Among distribution was from 15 years to 40 years with the mean age of 24 years. Among the 15 cases, 9 cases were male and 7 were female. 2. Ruptured sinus is right coronary sinus projecting to right ventricle in all 15 cases. Combined diseases are ventricular septal defect in 12 cases, Aortic Valvular heart disease in 4 cases, and narrowing of right ventricular outflow tract in 2 cases, and aneurysmal dilatation of right pulmonary artery in 1 cases. 3. Chest X-ray findings were that of left to right shunt, i.e, cardiomegaly, increased pulmonary vascularity but were normal in 3 cases. 4. Aortography showed sequential leakage of dye from right coronary sinus to right ventricle and finally to pulmonary artery in 9 cases, and in 9 cases of them the leakage is directly to right ventricular outflow tract without filling of sinus portion of the ventricle., i.e., type I. 5. The leakage was well shown in left ventricular diastolic phase and not shown in systolic phase. 6. Ventricular septal defects were not detected definitely in spite of taking left ventriculography. 7. Cine angiography is essential for detecting accurate site, degree and direction of sinus valsalva rupture and other associated cardiac abnormality

  4. Ruptured ectopic pregnancy diagnosed with computed tomography

    International Nuclear Information System (INIS)

    Michalak, Maciej; Żurada, Anna; Biernacki, Maciej; Zygmunt, Kozielec

    2010-01-01

    The rupture of ectopic pregnancy (EP) still remains the primary and direct cause of death in the first trimester of pregnancy. Ultrasonography is known to be a modality of choice in EP diagnostics. We found a severe discrepancy between the frequency of ectopic pregnancies (EP) and the number of available computed tomography (CT) examinations. A 29-year-old woman was admitted to the emergency department with a history of abdominal pain, nausea, vomiting and collapse. Sonographic findings of a suspected EP were unclear. Moreover, not all features of intrauterine pregnancy were present. Due to the patient’s life-threatening condition, an emergency multi-slice CT with MPR and VRT reconstructions was performed, revealing symptoms of a ruptured EP. In the right adnexal area, a well-vascularized, solid-cystic abnormal mass lesion was found. Intraperitoneal hemorrhage was confirmed intraoperatively, and the right fallopian tube with a tubal EP was resected. In the surgery in situ, as well as in the pathological examination of the tumor mass, a human embryo of approximately 1.5 cm in length (beginning of the 8 th week of gestation) was found. Although ultrasonography still remains the first-line imaging examination in EP diagnostics, sometimes the findings of suspected EPs are unclear and not sufficient. The rupture of EP, with serious bleeding and symptoms of shock, may require an emergent pelvic and abdominal CT inspection. A clear correlation was found between the macroscopic CT images and the intraoperatively sampled material

  5. Influence of flowing sodium on creep deformation and rupture behaviour of 316L(N) austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@igcar.gov.in [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Laha, K.; Mathew, M.D. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Vijayaraghavan, S.; Shanmugavel, M.; Rajan, K.K. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Jayakumar, T. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2012-08-15

    The influence of flowing sodium on creep deformation and rupture behaviour of AISI 316L(N) austenitic stainless steel has been investigated at 873 K over a stress range of 235-305 MPa. The results were compared with those obtained from testing in air environment. The steady state creep rates of the material were not influenced appreciably by the testing environments. The time to onset of tertiary stage of creep deformation was delayed in sodium environment. The creep-rupture lives of the material increased in sodium environment, which became more pronounced at lower applied stresses. The increase in rupture life of the material in flowing sodium was accompanied by an increase in rupture ductility. The creep damage on specimen surface as well as inside the specimen was less in specimen tested in sodium. SEM fractographic investigation revealed predominantly transgranular dimple failure for the specimen tested in sodium, whereas predominantly intergranular creep failure was observed in the air tested specimens. Almost no oxidation was observed in the specimens creep tested in the sodium environment. Absence of oxidation and less creep damage cavitation extended the secondary state in liquid sodium tests and lead to increase in creep rupture life and ductility of the material as compared to in air.

  6. Pressurization rate effect on ligament rupture and burst pressures of cracked steam generator tubes

    International Nuclear Information System (INIS)

    Majumdar, S.; Kasza, K.

    2009-01-01

    The question of whether ligament rupture pressure or unstable burst pressure may vary significantly with pressurization rate at room temperature arose from the results of pressure tests by industry on tubes with machined part-throughwall notches. Slow (quasi-static) and fast 14 MPa/s (2000 psi/s) pressurization rate tests on specimens with nominally the same notch geometry appeared to show a significant effect of the rate of pressurization on the unstable burst pressure. Unfortunately, the slow and fast loading rate tests were conducted following two different test procedures, which could confound the results. The current series of tests were conducted on a variety of specimen geometries using a consistent test procedure to better establish the effect of pressurization rate on ligament rupture and burst pressures. (author)

  7. Pressurization rate effect on ligament rupture and burst pressures of cracked steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Majumdar, S.; Kasza, K. [Argonne National Laboratory, Nuclear Energy Division, Lemont, Illinois (United States)

    2009-07-01

    The question of whether ligament rupture pressure or unstable burst pressure may vary significantly with pressurization rate at room temperature arose from the results of pressure tests by industry on tubes with machined part-throughwall notches. Slow (quasi-static) and fast 14 MPa/s (2000 psi/s) pressurization rate tests on specimens with nominally the same notch geometry appeared to show a significant effect of the rate of pressurization on the unstable burst pressure. Unfortunately, the slow and fast loading rate tests were conducted following two different test procedures, which could confound the results. The current series of tests were conducted on a variety of specimen geometries using a consistent test procedure to better establish the effect of pressurization rate on ligament rupture and burst pressures. (author)

  8. Liver Hydatid Cyst with Transdiaphragmatic Rupture and Lung Hydatid Cyst Ruptured into Bronchi and Pleural Space

    International Nuclear Information System (INIS)

    Arıbaş, Bilgin Kadri; Dingil, Gürbüz; Köroğlu, Mert; Üngül, Ümit; Zaralı, Aliye Ceylan

    2011-01-01

    The aim of this case study is to present effectiveness of percutaneous drainage as a treatment option of ruptured lung and liver hydatid cysts. A 65-year-old male patient was admitted with complicated liver and lung hydatid cysts. A liver hydatid cyst had ruptured transdiaphragmatically, and a lung hydatid cyst had ruptured both into bronchi and pleural space. The patient could not undergo surgery because of decreased respiratory function. Both cysts were drained percutaneously using oral albendazole. Povidone–iodine was used to treat the liver cyst after closure of the diaphragmatic rupture. The drainage was considered successful, and the patient had no recurrence of signs and symptoms. Clinical, laboratory, and radiologic recovery was observed during 2.5 months of catheterization. The patient was asymptomatic after catheter drainage. No recurrence was detected during 86 months of follow-up. For inoperable patients with ruptured liver and lung hydatid cysts, percutaneous drainage with oral albendazole is an alternative treatment option to surgery. The percutaneous approach can be life-saving in such cases.

  9. Effect of Post-Weld Heat Treatment on Creep Rupture Properties of Grade 91 Steel Heavy Section Welds

    Energy Technology Data Exchange (ETDEWEB)

    Li, Leijun

    2012-11-02

    This project will conduct a systematic metallurgical study on the effect of post-weld heat treatment (PWHT) on the creep rupture properties of P91 heavy section welds. The objective is to develop a technical guide for selecting PWHT parameters, and to predict expected creep-rupture life based on the selection of heat treatment parameters. The project consists of four interdependent tasks: Experimentally and numerically characterize the temperature fields of typical post-weld heat treatment procedures for various weld and joint configurations to be used in Gen IV systems. Characterize the microstructure of various regions, including the weld fusion zone, coarse-grain heat-affected zone, and fine-grain heat affected zone, in the welds that underwent the various welding and PWHT thermal histories. Conduct creep and creep-rupture testing of coupons extracted from actual and physically simulated welds. Establish the relationship among PWHT parameters, thermal histories, microstructure, creep, and creep-rupture properties.

  10. NEONATAL COMPLICATIONS OF PREMATURE RUPTURE OF MEMBRANES

    Directory of Open Access Journals (Sweden)

    F. Nili AA. Shams Ansari

    2003-07-01

    Full Text Available Premature rupture of membranes (PROM is one of the most common complications of pregnancy that has a major impact on neonatal outcomes. With respect to racial, nutritional and cultural differences between developed and developing countries, this study was conducted to detect the prevalence of neonatal complications following PROM and the role of the duration of rupture of membranes in producing morbidities and mortalities in these neonates in our hospital. Among 2357 pregnant women, we found 163 (6.91% cases of premature rupture of the fetal membranes in Tehran Vali-e-Asr Hospital during April 2001 to April 2002. Route of delivery was cesarean section in 65.6% of women. Urinary tract infection occured in 1.8%, maternal leukocytosis and fever in 20.2% and 5.5%, chorioamnionitis in 6.1%, fetal tachycardia in 1.2% and olygohydramnios in 4.9%. Gestational age in 138 (86% of neonates was less than 37 completed weeks. Thirty five infants (21.47% had respiratory distress syndrome and 33 (20.245% had clinical sepsis. Pneumonia in 6 (3.7% and skeletal deformity in 7 (4.294% were seen. Rupture of membrane of more than 24 hours duration occurred in 71 (43.6% of the patients. Comparison of morbidities between two groups of neonates and their mothers according to the duration of PROM (less and more than 24 hours showed significant differences in NICU admission, olygohydramnios, maternal fever, leukocytosis and chorioamnionitis rates (p24 hr of PROM with an odds ratio of 2.68 and 2.73, respectively. Positive blood and eye cultures were detected in 16 cases during 72 hours of age. Staphylococcus species, klebsiella, E.coli and streptococcus were the predominant organisms among positive blood cultures. Mortality was seen in 18 (11% of neonates because of respiratory failure, disseminated intravascular coagulation, septic shock, and a single case of congenital toxoplasmosis. In this study, the prevalence of prematurity, sepsis and prolonged rupture of membrane

  11. Management of diaphragmatic rupture from blunt trauma.

    Science.gov (United States)

    Tan, K K; Yan, Z Y; Vijayan, A; Chiu, M T

    2009-12-01

    Diagnosis of diaphragmatic rupture is difficult, and delays could result in a catastrophic outcome. We reviewed our institution's management of patients with diaphragmatic rupture after blunt trauma. All patients in this study were treated at Tan Tock Seng Hospital, Singapore, from March 2002 to October 2008. Patients with penetrating injuries were excluded. The parameters included age, mechanism of injury, haemodynamic status at admission, Glasgow coma scale (GCS) score, injury severity score (ISS), imaging studies, location of diaphragmatic injuries, associated injuries and outcome. 14 patients with a median age of 38 years formed the study group. Vehicular-related incidents accounted for 71.4 percent of the injuries. The median GCS score on admission was 14 (range 3-15), while the median systolic blood pressure and heart rate were 94 (range 50-164) mmHg and 110 (range 76-140) beats per minute, respectively. The median ISS was 41 (range 14-66). All had chest radiographs performed in the emergency department, six (42.9 percent) had computed tomography performed before surgery, while the remaining eight (57.1 percent) were sent straight to the operating theatre from the emergency department. There were five (35.7 percent) right-sided and nine (64.3 percent) left-sided diaphragmatic ruptures. The mortality rate was 35.7 percent. Some of the associated injuries included eight (57.1 percent) splenic lacerations, five (35.7 percent) haemothorax and lung injuries, four (28.6 percent) bone fractures and three (21.4 percent) liver lacerations. 12 (85.7 percent) patients underwent repair of the diaphragmatic rupture using interrupted polypropylene suture, while the remaining two (14.3 percent) were too haemodynamically unstable to undergo definitive treatment. Advanced age, haemodynamic instability and raised ISS were associated with mortality. An accurate diagnosis of diaphragmatic rupture in trauma patients is difficult, and a thorough examination of both the

  12. Rupture mechanics of metallic alloys for hydrogen transport

    International Nuclear Information System (INIS)

    Moro, I.; Briottet, L.; Lemoine, P.; Andrieu, E.; Blanc, C.

    2007-01-01

    With the aim to establish a cheap hydrogen distribution system, the transport by pipelines is a solution particularly interesting. Among the high limit of elasticity steels, the X80 has been chosen for hydrogen transport. Its chemical composition and microstructure are given. Important microstructural changes have been revealed in the sheet thickness: the microstructure is thinner and richer in perlite in surface than in bulk. In parallel to this microstructural evolution, a microhardness gradient has been observed: the material microhardness is stronger in surface than in bulk of the sheet. The use of this material for hydrogen transport requires to study its resistance to hydrogen embrittlement. The main aim of this work is to develop an easy rupture mechanics test allowing to qualify the studied material in a gaseous hydrogen environment, to determine the sensitivity of the studied material to the hydrogen embrittlement and to better understand the mechanisms of the hydrogen embrittlement for ferritic materials. Two experimental tests have been used for: the first one is a traction machine coupled to an autoclave; the second one allows to carry out disk rupture tests. The toughness of the material in a gaseous hydrogen environment has thus been determined. The resistance of the material to hydrogen embrittlement has been characterized and by simulation, it has been possible to identify the areas with a strong concentration in hydrogen. The second aim of this work is to study the influence of the steel microstructure on the hydrogen position in the material and on the resistance of the material to the hydrogen embrittlement. The preferential trapping sites on the material not mechanically loaded have at first been identified, as well as the hydrogen position on the different phases and at the ferrite/cementite interface. The interaction between the mechanical loads, the position and the trapping of the hydrogen have been studied then. At last, has been

  13. Burnout and gate rupture of power MOS transistors with fission fragments of 252Cf

    International Nuclear Information System (INIS)

    Tang Benqi; Wang Yanping; Geng Bin; Chen Xiaohua; He Chaohui; Yang Hailiang

    2000-01-01

    A study to determine the single event burnout (SEB) and single event gate rupture (SEGR) sensitivities of power MOSFET devices is carried out by exposure to fission fragments from 252 Cf source. The test method, test results, a description of observed burnout current waveforms and a discussion of a possible failure mechanism are presented. The test results include the observed dependence upon applied drain or gate to source bias and effect of external capacitors and limited resistors

  14. Study on tube rupture strength evaluation method for rapid overheating

    International Nuclear Information System (INIS)

    Komine, Ryuji; Wada, Yusaku

    1998-08-01

    A sodium-water reaction derived from the single tube break in steam generator might overheat neighbor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. In the present study this phenomenon was recognized as the fracture of cylindrical tube with the large deformation due to overheating, and the evaluation method was investigated based on both of experimental and analytical approaches. The results obtained are as follows. (1) As for the nominal stress estimation, it was clarified through the experimental data and the detailed FEM elasto-plastic large deformation analysis that the formula used in conventional designs can be applied. (2) Within the overheating temperature limits of tubes, the creep effect is dominant, even if the loading time is too short. So the strain rate on the basis of JIS elevated temperature tensile test method for steels and heat-resisting alloys is too late and almost of total strain is composed by creep one. As a result the time dependent effect cannot be evaluated under JIS strain rate condition. (3) Creep tests in shorter time condition than a few minutes and tensile tests in higher strain rate condition than 10%/min of JIS are carried out for 2 1/4Cr-1Mo(NT) steel, and the standard values for tube rupture strength evaluation are formulated. (4) The above evaluation method based on both of the stress estimation and the strength standard values application is justified by using the tube burst test data under internal pressure. (5) The strength standard values on Type 321 ss is formulated in accordance with the procedure applied for 2 1/4Cr-1Mo(NT) steel. (author)

  15. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  16. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    Science.gov (United States)

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  17. MR findings of ruptured endometrial cyst: Comparison with tubo-ovarian abscess

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Yasumoto, Mayumi; Matsumoto, Reiko; Andoh, Akihiko

    2012-01-01

    Objective: To evaluate the MR findings of ruptured endometrial cyst, focusing on the differentiation from tubo-ovarian abscess (TOA). Patients and methods: We reviewed the records of 21 patients who underwent preoperative MR examinations for TOAs (n = 15) or ruptured endometrial cysts (n = 6). We evaluated the presence of hyper-intense ascites and hyper-intense peritoneum in T1-weighted sequences, strong enhancement of the peritoneum, hyper-intense content and hyper-intense rim of the ovarian lesion in T1-weighted sequences, and strong wall enhancement of the ovarian lesion. χ 2 test was used to assess the relationship between TOA cases versus cases with ruptured endometrial cysts, and the three MR peritoneal findings. We evaluated the relationship between TOA versus non-infected endometrial cysts, and the ovarian MR peritoneal findings, too. Results: Hyper-intense ascites was found in all of the patients with ruptured endometrial cyst and none with TOA (p < 0.0001). Hyper-intense peritoneum was observed in only TOAs cases (4 of 8). Strong peritoneal enhancement was seen in 3 of the 3 patients with ruptured endometrial cyst and 7 of the 13 patients with TOA (p = 0.1366). Hyper-intense content of the ovarian lesion was seen more often in the non-infected endometrial cysts than in the TOAs (p = 0.001607), while hyper-intense rim was more frequent in TOAs (p = 0.000402). Strong wall enhancement was observed only in TOAs (11 of 15) (p = 0.001355). Conclusions: MR images are useful to differentiate ruptured endometrial cyst from TOA.

  18. Isokinetic strength and endurance after percutaneous and open surgical repair of Achilles tendon ruptures.

    Science.gov (United States)

    Goren, David; Ayalon, Moshe; Nyska, Meir

    2005-04-01

    Reports on complete spontaneous Achilles tendon ruptures and associated treatment have become more frequent in the literature in the past two decades, as has the request for treatments that enable the finest possible functional recovery. The best available treatment is a matter of considerable controversy in the literature. The purpose of this study was to compare the isokinetic strength and endurance of the plantarflexor muscle-tendon unit in subjects who sustained rupture of the Achilles tendon and underwent either open surgery or closed percutaneous repair of the Achilles tendon. Twenty patients (18 males, 2 females) with spontaneous ruptures of the Achilles tendon were included in this study. Ten patients were treated by open surgery, and 10 patients were treated percutaneously. All patients had ruptured their Achilles tendon more than 6 months before the study, and all of the ruptures occurred 3.5 years or less before the day of the testing. All patients underwent an oriented physical examination. An isokinetic Biodex dynamometer (Biodex Medical System, Shirley, NY) was used to measure ankle joint angle, and in plantarflexion to calculate the torque at the ankle joint (Newton/meter), and the average work (jouls) for both maximal power and endurance. Each measurement was compared to the normal ankle. Biodex dynamometer evaluations at 90 deg/sec demonstrated a significant difference of maximal voluntary plantarflexor torque, endurance performance and range of motion at the ankle joint between the involved and uninvolved sides in patients treated by either mode of treatment. Yet, no statistically significant differences were revealed for the parameters mentioned above between the subjects that were treated either percutaneously or by an open surgery. In functional terms, the biomechanical outcomes of open surgery and percutaneous repair for acute ruptures of the Achilles tendon are both effective.

  19. MR findings of ruptured endometrial cyst: Comparison with tubo-ovarian abscess

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shigeru, E-mail: shig.suz@gmail.com [Department of Radiology, Saitama Red Cross Hospital, 8-3-33 Kamiochiai, Chuo-ku, Saitama, 338-8553 (Japan); Yasumoto, Mayumi, E-mail: Mayumihoo@yahoo.co.jp [Department of Radiology, Saitama Red Cross Hospital, 8-3-33 Kamiochiai, Chuo-ku, Saitama, 338-8553 (Japan); Matsumoto, Reiko, E-mail: rad@saitama-med.jrc.or.jp [Department of Radiology, Saitama Red Cross Hospital, 8-3-33 Kamiochiai, Chuo-ku, Saitama, 338-8553 (Japan); Andoh, Akihiko, E-mail: a-andoh@silk.plala.or.jp [Department of Obstetrics and Gynecology, Saitama Red Cross Hospital, 8-3-33 Kamiochiai, Chuo-ku, Saitama, 338-8553 (Japan)

    2012-11-15

    Objective: To evaluate the MR findings of ruptured endometrial cyst, focusing on the differentiation from tubo-ovarian abscess (TOA). Patients and methods: We reviewed the records of 21 patients who underwent preoperative MR examinations for TOAs (n = 15) or ruptured endometrial cysts (n = 6). We evaluated the presence of hyper-intense ascites and hyper-intense peritoneum in T1-weighted sequences, strong enhancement of the peritoneum, hyper-intense content and hyper-intense rim of the ovarian lesion in T1-weighted sequences, and strong wall enhancement of the ovarian lesion. {chi}{sup 2} test was used to assess the relationship between TOA cases versus cases with ruptured endometrial cysts, and the three MR peritoneal findings. We evaluated the relationship between TOA versus non-infected endometrial cysts, and the ovarian MR peritoneal findings, too. Results: Hyper-intense ascites was found in all of the patients with ruptured endometrial cyst and none with TOA (p < 0.0001). Hyper-intense peritoneum was observed in only TOAs cases (4 of 8). Strong peritoneal enhancement was seen in 3 of the 3 patients with ruptured endometrial cyst and 7 of the 13 patients with TOA (p = 0.1366). Hyper-intense content of the ovarian lesion was seen more often in the non-infected endometrial cysts than in the TOAs (p = 0.001607), while hyper-intense rim was more frequent in TOAs (p = 0.000402). Strong wall enhancement was observed only in TOAs (11 of 15) (p = 0.001355). Conclusions: MR images are useful to differentiate ruptured endometrial cyst from TOA.

  20. Low footwall accelerations and variable surface rupture behavior on the Fort Sage Mountains fault, northeast California

    Science.gov (United States)

    Briggs, Richard W.; Wesnousky, Steven G.; Brune, James N.; Purvance, Matthew D.; Mahan, Shannon

    2013-01-01

    The Fort Sage Mountains fault zone is a normal fault in the Walker Lane of the western Basin and Range that produced a small surface rupture (L 5.6 earthquake in 1950. We investigate the paleoseismic history of the Fort Sage fault and find evidence for two paleoearthquakes with surface displacements much larger than those observed in 1950. Rupture of the Fort Sage fault ∼5.6  ka resulted in surface displacements of at least 0.8–1.5 m, implying earthquake moment magnitudes (Mw) of 6.7–7.1. An older rupture at ∼20.5  ka displaced the ground at least 1.5 m, implying an earthquake of Mw 6.8–7.1. A field of precariously balanced rocks (PBRs) is located less than 1 km from the surface‐rupture trace of this Holocene‐active normal fault. Ground‐motion prediction equations (GMPEs) predict peak ground accelerations (PGAs) of 0.2–0.3g for the 1950 rupture and 0.3–0.5g for the ∼5.6  ka paleoearthquake one kilometer from the fault‐surface trace, yet field tests indicate that the Fort Sage PBRs will be toppled by PGAs between 0.1–0.3g. We discuss the paleoseismic history of the Fort Sage fault in the context of the nearby PBRs, GMPEs, and probabilistic seismic hazard maps for extensional regimes. If the Fort Sage PBRs are older than the mid‐Holocene rupture on the Fort Sage fault zone, this implies that current GMPEs may overestimate near‐fault footwall ground motions at this site.

  1. Neonatal survival after prolonged preterm premature rupture of membranes before 24 weeks of gestation.

    Science.gov (United States)

    Brumbaugh, Jane E; Colaizy, Tarah T; Nuangchamnong, Nina; O'Brien, Emily A; Fleener, Diedre K; Rijhsinghani, Asha; Klein, Jonathan M

    2014-11-01

    To evaluate neonatal survival after prolonged preterm premature rupture of membranes (PROM) in the era of antenatal corticosteroids, surfactant, and inhaled nitric oxide. A single-center retrospective cohort study of neonates born from 2002-2011 after prolonged (1 week or more) preterm (less than 24 weeks of gestation) rupture of membranes was performed. The primary outcome was survival to discharge. Neonates whose membranes ruptured less than 24 hours before delivery (n=116) were matched (2:1) on gestational age at birth, sex, and antenatal corticosteroid exposure with neonates whose membranes ruptured 1 week or more before delivery (n=58). Analysis used conditional logistic regression for categorical data and Wilcoxon signed rank test for continuous data. The prolonged preterm PROM exposed and unexposed cohorts had survival rates of 90% and 95%, respectively, although underpowered to assess the statistical significance (P=.313). Exposed neonates were more likely have pulmonary hypoplasia (26/58 exposed, 1/114 unexposed, Prupture (20.4 weeks exposed, 22.3 weeks unexposed, P=.189), length of rupture (3.7 weeks exposed, 6.4 weeks unexposed, P=.717), and lowest maximal vertical pocket before 24 weeks of gestation (0 cm exposed, 1.4 cm unexposed, P=.114) did not discriminate between survivors and nonsurvivors after exposure to prolonged preterm PROM. With antenatal steroid exposure and aggressive pulmonary management, survival to discharge after prolonged preterm PROM was 90%. Pulmonary morbidities were common. Of note, the data were limited to women who remained pregnant 1 week or longer after rupture of membranes.

  2. In-reactor creep of zirconium alloys by thermal spikes

    International Nuclear Information System (INIS)

    Ibrahim, E.F.

    1975-01-01

    The size and duration of thermal spikes from fast neutrons have been calculated for zirconium alloys, showing that spikes up to 1.8 nm radius may exist for 2 x 10 -11 s at greater than melting point, at 570K ambient temperature. Creep rates have been calculated assuming that the elastic strain from the applied stress relaxes in the volume of the spikes (by preferential loop alignment or modification of an existing dislocation network). The calculated rates are consistent with strain rates observed in long term tests-in-reactor, if spike lifetimes are 2 to 2.5 x 10 -11 s. (Auth.)

  3. Elevated temperature design of KALIMER reactor internals accounting for creep and stress-rupture effects

    International Nuclear Information System (INIS)

    Koo, Gyeong Hoi; Yoo, Bong

    2000-01-01

    In most LMFBR (Liquid Metal Fast Breed Reactor) design, the operating temperature is very high and the time-dependent creep and stress-rupture effects become so important in reactor structural design. Therefore, unlike with conventional PWR, the normal operating conditions can be basically dominant design loading because the hold time at elevated temperature condition is so long and enough to result in severe total creep ratcheting strains during total service lifetime. In this paper, elevated temperature design of the conceptually designed baffle annulus regions of KALIMER (Korea Advanced Liquid Metal Reactor) reactor internal structures is carried out for normal operating conditions which have the operating temperature 530 deg. C and the total service lifetime of 30 years. For the elevated temperature design of reactor internal structures, the ASME Code Case N-201-4 is used. Using this code, the time-dependent stress limits, the accumulated total inelastic strain during service lifetime, and the creep-fatigue damages are evaluated with the calculation results by the elastic analysis under conservative assumptions. The application procedures of elevated temperature design of the reactor internal structures using ASME code case N-201-4 with the elastic analysis method are described step by step in detail. This paper will be useful guide for actual application of elevated temperature design of various reactor types accounting for creep and stress-rupture effects. (author)

  4. Fluid mixing in reactor containment

    International Nuclear Information System (INIS)

    Deoras M Prabhudharwadkar; Kannan N Iyer

    2005-01-01

    Full text of publication follows: Hydrogen release and distribution in nuclear power plant containment is an important safety issue. Selection of a proper turbulence model is important for accurate estimation of the mixing process. The selection of turbulence model is dictated by the best compromise between accuracy and computational efforts. For this, three different turbulence models, viz. Standard k-ε, RNG k-ε and Reynolds Stress Model, based on Reynolds averaged Navier Stokes equations (RANS) approach, were used. The computations were done using the CFD code FLUENT, which is based on the control volume methodology. The computational results were compared with the experimental results of HYMIS test facility, where helium was used to simulate hydrogen. The processes of helium plume rise, multiple plume merging, distribution and mixing were studied. Based on these computations, a simple analytical/empirical zone based model was formulated for the same problem, which predicted the helium concentration reasonably accurately and quickly. (authors)

  5. Ion thermometers in reactor technology

    International Nuclear Information System (INIS)

    Yakesh, D.; Kott, J.; Strnad, M.

    1980-01-01

    The width of the temperature discontinuity and the thermometric stability of the sensors are constant up to very high flux values. The immediate influence of irradiation is reduced to a decrease in the hysteresis of the conduction curve at the phase transition. When the readings of the ion thermometers are compared with the reading of Chromel-Alumel thermocouples, it is observed that the temperature difference amounts to approximately 7/degree/C in the case of thermocouples placed at the sensor socket; the temperature difference decreases to 2/degree/C in the case of the thermocouple junction situated between the electrodes. The good results obtained in the testing of the ion thermometers in nuclear reactors lead to the conclusion that these temperature sensors are promising for checking thermocouples in the core of nuclear power stations

  6. Induced seismicity provides insight into why earthquake ruptures stop

    KAUST Repository

    Galis, Martin

    2017-12-21

    Injection-induced earthquakes pose a serious seismic hazard but also offer an opportunity to gain insight into earthquake physics. Currently used models relating the maximum magnitude of injection-induced earthquakes to injection parameters do not incorporate rupture physics. We develop theoretical estimates, validated by simulations, of the size of ruptures induced by localized pore-pressure perturbations and propagating on prestressed faults. Our model accounts for ruptures growing beyond the perturbed area and distinguishes self-arrested from runaway ruptures. We develop a theoretical scaling relation between the largest magnitude of self-arrested earthquakes and the injected volume and find it consistent with observed maximum magnitudes of injection-induced earthquakes over a broad range of injected volumes, suggesting that, although runaway ruptures are possible, most injection-induced events so far have been self-arrested ruptures.

  7. The effectiveness of 3D animations to enhance understanding of cranial cruciate ligament rupture.

    Science.gov (United States)

    Clements, Dylan N; Broadhurst, Henry; Clarke, Stephen P; Farrell, Michael; Bennett, David; Mosley, John R; Mellanby, Richard J

    2013-01-01

    Cranial cruciate ligament (CCL) rupture is one of the most important orthopedic diseases taught to veterinary undergraduates. The complexity of the anatomy of the canine stifle joint combined with the plethora of different surgical interventions available for the treatment of the disease means that undergraduate veterinary students often have a poor understanding of the pathophysiology and treatment of CCL rupture. We designed, developed, and tested a three dimensional (3D) animation to illustrate the pertinent clinical anatomy of the stifle joint, the effects of CCL rupture, and the mechanisms by which different surgical techniques can stabilize the joint with CCL rupture. When compared with a non-animated 3D presentation, students' short-term retention of functional anatomy improved although they could not impart a better explanation of how different surgical techniques worked. More students found the animation useful than those who viewed a comparable non-animated 3D presentation. Multiple peer-review testing is required to maximize the usefulness of 3D animations during development. Free and open access to such tools should improve student learning and client understanding through wide-spread uptake and use.

  8. Spontaneous Tricuspid Valve Chordal Rupture in Idiopathic Pulmonary Hypertension.

    Science.gov (United States)

    Rodrigues, Ana Clara Tude; Afonso, José E; Cordovil, Adriana; Monaco, Claudia; Piveta, Rafael; Cordovil, Rodrigo; Fischer, Claudio H; Vieira, Marcelo; Lira-Filho, Edgar; Morhy, Samira S

    2016-03-01

    Rupture of tricuspid valve is unusual, occurring mainly in the setting of blunt trauma or endomyocardial biopsy. Spontaneous tricuspid valve chordal rupture is particularly rare. We report herein a case of a patient with severe pulmonary hypertension, on the lung transplantation waiting list, who presented with spontaneous chordal rupture, exacerbation of tricuspid insufficiency and worsening of clinical status. Diagnosis and treatment, along with possible mechanisms for this complication, are discussed. © 2015, Wiley Periodicals, Inc.

  9. [Delayed rupture of the spleen in a multiply injured patient].

    Science.gov (United States)

    Lică, I; Venter, M D; Mehic, R; Marian, R; Ionescu, G

    1997-01-01

    The authors present a case of delayed rupture of the spleen in a polytraumatised patient. This entity was defined as a late occurrence of signs and symptoms attributed to splenic injury not detected by diagnostic computed tomographic scanning during the initial examination. The mechanisms in which the delayed rupture of the spleen occurs are discussed and the conclusion is that the delayed rupture of the spleen represent a real clinical entity.

  10. Rupture of popliteal arterial aneurysm due to salmonella infection

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Oh, Hyung Woo; Kim, Dong Hyun; Byun, Joo Nam

    2006-01-01

    We report here on a case of popliteal aneurysm and rupture that occurred over a 10-day period and this was all secondary to salmonella infection. Computed tomography (CT) angiography of the extremity that was performed before and after aneurysmal rupture showed the aneurysm's rapid evolution to rupture over a short period of time. We also review the pathogenesis, clinical presentation, diagnostic approach and management of salmonella aneurysms

  11. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    DEFF Research Database (Denmark)

    Wernheden, Erika; Brenøe, Anne Sofie; Shahidi, Saeid

    2017-01-01

    Splenic artery aneurysms (SAAs) are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm) SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured...... 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA....

  12. Misdiagnosed Uterine Rupture of an Advanced Cornual Pregnancy

    Directory of Open Access Journals (Sweden)

    Christian Linus Hastrup Sant

    2012-01-01

    Full Text Available Cornual pregnancy is a diagnostic and therapeutic challenge with potential severe consequences if uterine rupture occurs with following massive intraabdominal bleeding. We report a case of a misdiagnosed ruptured cornual pregnancy occurring at 21 weeks of gestation. Ultrasound examination and computer tomography revealed no sign of abnormal pregnancy. The correct diagnosis was first made at emergency laparotomy. Uterine rupture should be considered in pregnant women presenting with abdominal pain and haemodynamic instability.

  13. Misdiagnosed uterine rupture of an advanced cornual pregnancy

    DEFF Research Database (Denmark)

    Sant, Christian Linus Hastrup; Andersen, Poul Erik

    2012-01-01

    Cornual pregnancy is a diagnostic and therapeutic challenge with potential severe consequences if uterine rupture occurs with following massive intraabdominal bleeding. We report a case of a misdiagnosed ruptured cornual pregnancy occurring at 21 weeks of gestation. Ultrasound examination...... and computer tomography revealed no sign of abnormal pregnancy. The correct diagnosis was first made at emergency laparotomy. Uterine rupture should be considered in pregnant women presenting with abdominal pain and haemodynamic instability....

  14. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  15. Surgical repair of a rupture of the pectoralis major muscle

    Science.gov (United States)

    Pochini, Alberto De Castro; Andreoli, Carlos Vicente; Ejnisman, Benno; Maffulli, Nicola

    2015-01-01

    Muscle rupture is rarely treated surgically. Few reports of good outcomes after muscular suture have been published. Usually, muscular lesions or partial ruptures heal with few side effects or result in total recovery. We report a case of an athlete who was treated surgically to repair a total muscular rupture in the pectoralis major muscle. After 6 months, the athlete returned to competitive practice. After a 2-year follow-up, the athlete still competes in skateboard championships. PMID:25716033

  16. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  17. Secondary pipe rupture at Mihama unit 3

    International Nuclear Information System (INIS)

    Hajime Ito; Takehiko Sera

    2005-01-01

    The secondary system pipe rupture occurred on August 9, 2004, while Mihama unit 3 was operating at the rated thermal power. The rupture took place on the condensate line-A piping between the No.4 LP heater and the deaerator, downstream of an orifice used for measuring the condensate flux. The pipe is made of carbon steel, and normally has 558.8 mm diameter and 10 mm thickness. The pipe wall had thinned to 0.4 mm at the point of minimum thickness. It is estimated that the disturbed flow of water downstream of the orifice caused erosion/corrosion and developed wall thinning, leading to a rupture at the thinnest section under internal pressure, about 1MPa. Observation of the pipe internal surface revealed a scale-like pattern typical in this kind of phenomenon. Eleven workers who were preparing for an annual outage that was to start from August 14 suffered burn injuries, of who five died. Since around 1975, we, Kansai Electric, have been checking pipe wall thickness while focusing on the thinning of carbon steel piping in the secondary system. Summarizing the results from such investigation and reviewing the latest technical knowledge including operating experience from overseas utilities, we compiled the pipe thickness management guideline for PWR secondary pipes, 1990. The pipe section that ruptured at the Mihama unit 3 should have been included within the inspection scopes according to the guideline but was not registered on the inspection list. It had not been corrected for almost thirty years. As the result, this pipe section had not been inspected even once since the beginning of the plant operation, 1976. It seems that the quality assurance and maintenance management had not functioned well regarding the secondary system piping management, although we were responsible for the safety of nuclear power plants as licensee. We will review the secondary system inspection procedure and also improve the pipe thickness management guideline. And also, we would replace

  18. Atherosclerotic plaque rupture and thrombosis. Evolving concepts.

    Science.gov (United States)

    Fuster, V; Stein, B; Ambrose, J A; Badimon, L; Badimon, J J; Chesebro, J H

    1990-09-01

    Rupture of an atherosclerotic plaque associated with partial or complete thrombotic vessel occlusion is fundamental to the development of ischemic coronary syndromes. Plaques that produce only mild-to-moderate angiographic luminal stenosis are frequently those that undergo abrupt disruption, leading to unstable angina or acute myocardial infarction. Plaques with increased lipid content appear more prone to rupture, particularly when the lipid pool is localized eccentrically within the intima. Macrophages appear to play an important role in atherogenesis, perhaps by participating in the uptake and metabolism of lipoproteins, secretion of growth factors, and production of enzymes and toxic metabolites that may facilitate plaque rupture. In addition, the particular composition or configuration of a plaque and the hemodynamic forces to which it is exposed may determine its susceptibility to disruption. Exposure of collagen, lipids, and smooth muscle cells after plaque rupture leads to the activation of platelets and the coagulation cascade system. The resulting thrombus may lead to marked reduction in myocardial perfusion and the development of an unstable coronary syndrome, or it may become organized and incorporated into the diseased vessel, thus contributing to the progression of atherosclerosis. In unstable angina, plaque disruption leads to thrombosis, which is usually labile and results in only a transient reduction in myocardial perfusion. Release of vasoactive substances, arterial spasm, or increases in myocardial oxygen demand may contribute to ischemia. In acute myocardial infarction, plaque disruption results in a more persistent thrombotic vessel occlusion; the extent of necrosis depends on the size of the artery, the duration of occlusion, the presence of collateral flow, and the integrity of the fibrinolytic system. Thrombi that undergo lysis expose a highly thrombogenic surface to the circulating blood, which has the capacity of activating platelets and

  19. Long-time rupture strength and creep behaviour of welded joints on heat-resistant CrMoV steels with 1 and 12% chrome

    International Nuclear Information System (INIS)

    Maier, G.; Maile, K.; Theofel, H.

    1985-01-01

    Power plant components in the creep range are damaged frequently in the weld joint zones. The investigation concentrated therefore on the reliability of the information supplied by tests on small- and large-size samples. Creep rupture tests of dissimilar welded joints (1% with 12% chrome) with variations of heat input and weld metal have been conducted. At creep rupture times of about 10 4 h all joints failed in the outside heat affected zone of the weaker base metal. Large-size samples, proved in comparison at same stresses, showed distinctly longer times to rupture. (orig.) [de

  20. Computed tomography diagnosis of hepatocellular carcinoma rupture haemorrhage

    International Nuclear Information System (INIS)

    Zhi Weike; Jiang Bin; Liu Jinquan; Li Sixia; Zhu Zhichang

    2004-01-01

    Objective: To evaluate the diagnostic value of hepatocellular carcinoma rupture hemorrhage using Computed Tomography. Methods: Six cases diagnosed hepatocellular carcinoma rupture hemorrhage were analyzed by morphic and histologic method and investigated the key point of scan in diagnosis. Result: The correct rate of hepatocellular carcinoma rupture hemorrhage by Computed Tomography is above 83 percent, it characteristic representation is strip and would high-density shadow after enhancement. Conclusion: The characteristic representation of hepatocellular carcinoma rupture hemorrhage is attain by Computed Tomography, which provides effective operation evidences for clinical operation. (authors)

  1. Triceps Ruptures After Fluoroquinolone Antibiotics: A Report of 2 Cases.

    Science.gov (United States)

    Shybut, Theodore B; Puckett, Ernest R

    Rupture of the triceps brachii tendon is exceedingly rare, and surgical repair is generally indicated. Fluoroquinolone antibiotics have been implicated in tendon pathology, including tendon ruptures. Triceps rupture has not been previously reported in the setting of fluoroquinolone antibiotic therapy. We present 2 cases of triceps tendon rupture after treatment with fluoroquinolones. In both cases, triceps repair was performed with good outcomes. These cases highlight a risk of fluoroquinolone-induced tendinopathy to athletes. The sports medicine team should be aware of this risk and consider it when choosing antibiotics to treat athletes.

  2. Risk factors affecting chronic rupture of the plantar fascia.

    Science.gov (United States)

    Lee, Ho Seong; Choi, Young Rak; Kim, Sang Woo; Lee, Jin Yong; Seo, Jeong Ho; Jeong, Jae Jung

    2014-03-01

    Prior to 1994, plantar fascia ruptures were considered as an acute injury that occurred primarily in athletes. However, plantar fascia ruptures have recently been reported in the setting of preexisting plantar fasciitis. We analyzed risk factors causing plantar fascia rupture in the presence of preexisting plantar fasciitis. We retrospectively reviewed 286 patients with plantar fasciitis who were referred from private clinics between March 2004 and February 2008. Patients were divided into those with or without a plantar fascia rupture. There were 35 patients in the rupture group and 251 in the nonrupture group. The clinical characteristics and risk factors for plantar fascia rupture were compared between the 2 groups. We compared age, gender, the affected site, visual analog scale pain score, previous treatment regimen, body mass index, degree of ankle dorsiflexion, the use of steroid injections, the extent of activity, calcaneal pitch angle, the presence of a calcaneal spur, and heel alignment between the 2 groups. Of the assessed risk factors, only steroid injection was associated with the occurrence of a plantar fascia rupture. Among the 35 patients with a rupture, 33 had received steroid injections. The odds ratio of steroid injection was 33. Steroid injections for plantar fasciitis should be cautiously administered because of the higher risk for plantar fascia rupture. Level III, retrospective comparative study.

  3. [Simultaneous Traumatic Rupture of Patellar Ligament and Contralateral Rupture of Quadriceps Femoris Muscle].

    Science.gov (United States)

    Hladký, V; Havlas, V

    2017-01-01

    Our paper presents a unique case of a 64-year-old patient after a fall, treated with oral antidiabetic drugs for type II diabetes mellitus. Following a series of examinations, a bilateral injury was diagnosed - patellar ligament tear on the right side and rupture of quadriceps femoris muscle on the left side. It is a rare injury, complicated by simultaneous involvement of both knee joints. The used therapy consisted of a bilateral surgery followed by gradual verticalisation, first with the support of a walking frame and later with the use of forearm crutches. During the final examination, the patient demonstrated full flexion at both knees, while an extension deficit of approx. 5 degrees was still present on the left side. The right knee X-ray showed a proper position of the patella after the removal of temporary tension band wire. Although the clinical results of operative treatment of both the patellar ligament rupture and rupture of quadriceps femoris muscle are in most cases good, early operative treatment, proper technique and post-operative rehabilitation are a prerequisite for success. Key words: knee injuries, patellar ligament, quadriceps muscle, rupture.

  4. The UCERF3 grand inversion: Solving for the long‐term rate of ruptures in a fault system

    Science.gov (United States)

    Page, Morgan T.; Field, Edward H.; Milner, Kevin; Powers, Peter M.

    2014-01-01

    We present implementation details, testing, and results from a new inversion‐based methodology, known colloquially as the “grand inversion,” developed for the Uniform California Earthquake Rupture Forecast (UCERF3). We employ a parallel simulated annealing algorithm to solve for the long‐term rate of all ruptures that extend through the seismogenic thickness on major mapped faults in California while simultaneously satisfying available slip‐rate, paleoseismic event‐rate, and magnitude‐distribution constraints. The inversion methodology enables the relaxation of fault segmentation and allows for the incorporation of multifault ruptures, which are needed to remove magnitude‐distribution misfits that were present in the previous model, UCERF2. The grand inversion is more objective than past methodologies, as it eliminates the need to prescriptively assign rupture rates. It also provides a means to easily update the model as new data become available. In addition to UCERF3 model results, we present verification of the grand inversion, including sensitivity tests, tuning of equation set weights, convergence metrics, and a synthetic test. These tests demonstrate that while individual rupture rates are poorly resolved by the data, integrated quantities such as magnitude–frequency distributions and, most importantly, hazard metrics, are much more robust.

  5. Long-term results after repair of ruptured and non-ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kuzmanović Ilija B.

    2004-01-01

    Full Text Available INTRODUCTION Abdominal aortic aneurysm can be repaired by elective procedure while asymptomatic, or immediately when it is complicated - mostly due to rupture. Treating abdominal aneurysm electively, before it becomes urgent, has medical and economical reason. Today, the first month mortality after elective operations of the abdominal aorta aneurysm is less than 3%; on the other hand, significant mortality (25%-70% has been recorded in patients operated immediately because of rupture of the abdominal aneurysm. In addition, the costs of elective surgical treatment are significantly lower. OBJECTIVE The objective of this study is to compare long-term survival of patients that underwent elective or immediate repair of abdominal aortic aneurysm (due to rupture, and to find out the factors influencing the long-term survival of these patients. MATERIAL AND METHODS Through retrospective review of prospectively collected data of the Institute for Cardiovascular Diseases of Clinical Center of Serbia, Belgrade, 56 patients that had elective surgery and 35 patients that underwent urgent operation due to rupture of abdominal aneurysm were followed up. Only the patients that survived 30 postoperative days were included in this review, and were followed up (ranging from 2 to 126 months. Electively operated patients were followed during 58.82 months on the average (range 7 to 122, and urgently operated were followed over 52.26 months (range 2 to 126. There was no significant difference of the length of postoperative follow-up between these two groups. RESULTS During this period, out of electively operated and immediately operated patients, 27 and 22 cases died, respectively. There was no significant difference (p>0,05a of long-term survival between these two groups. Obesity and early postoperative complications significantly decreased long-term survival of both electively and immediately operated patients. Graft infection, ventral hernia, aneurysm of

  6. Physical therapy in the conservative treatment for anterior cruciate ligament rupture followed by contralateral rupture: case report

    OpenAIRE

    Almeida, Gabriel Peixoto Leão; Arruda, Gilvan de Oliveira; Marques, Amélia Pasqual

    2014-01-01

    Although the surgical reconstruction be the obvious indication for the anterior cruciate ligament (ACL) lesion, there is no consensus on whether the results of surgery are superior to those obtained with nonsurgical management. The objective of this report was to describe a case of nonsurgical treatment for ACL rupture followed by a contralateral rupture. A 28-year-old female practitioner of muay-thai and handball suffered a non-contact ACL rupture in the left knee, and three months after the...

  7. Vaginal rupture and evisceration in a dog.

    Science.gov (United States)

    Prassinos, Nikitas N; Adamama-Moraitou, Katerina K; Ververidis, Haralabos N; Anagnostou, Tilemachos L; Kladakis, Stefanos E

    2010-09-01

    A 1.5-year-old German Shepherd mixed breed dog was admitted with mild haemorrhage from the vulva and a perineal mass of 24-hour duration, which had been first observed immediately after parturition. Parturition had occurred at low ambient temperature, and only one puppy survived out of the seven oversized fetuses. The dog was in poor body condition, dehydrated, hypothermic, depressed, non-ambulatory and in a state of shock. Intestinal loops, the urinary bladder and the uterine horns and body were protruding from the vulva. A true vaginal prolapse was also observed. The abdominal viscera were flushed with warm sterile saline solution, protected and maintained wet. The laboratory findings included moderate anaemia, leukocytosis, hypoalbuminaemia, azotaemia and elevated liver enzyme activities. Stabilisation of the dog's general condition was attempted before surgery. Antimicrobial and analgesic drugs were also administered. After exploratory laparotomy the protruding organs, which were in good condition, were reduced. A recent rupture in the vaginal wall, approximately 6 cm long, was observed. Ovariohysterectomy and partial vaginectomy were performed. The preoperative course of therapy was continued, but the bitch died 12 hours later. The probable cause of vaginal rupture and evisceration in this bitch was tenesmus and/or trauma due to the oversized fetuses.

  8. Neighbor Rupture Degree of Some Middle Graphs

    Directory of Open Access Journals (Sweden)

    Gökşen BACAK-TURAN

    2017-12-01

    Full Text Available Networks have an important place in our daily lives. Internet networks, electricity networks, water networks, transportation networks, social networks and biological networks are some of the networks we run into every aspects of our lives. A network consists of centers connected by links. A network is represented when centers and connections modelled by vertices and edges, respectively. In consequence of the failure of some centers or connection lines, measurement of the resistance of the network until the communication interrupted is called vulnerability of the network. In this study, neighbor rupture degree which is a parameter that explores the vulnerability values of the resulting graphs due to the failure of some centers of a communication network and its neighboring centers becoming nonfunctional were applied to some middle graphs and neighbor rupture degree of the $M(C_{n},$ $M(P_{n},$ $M(K_{1,n},$ $M(W_{n},$ $M(P_{n}\\times K_{2}$ and $M(C_{n}\\times K_{2}$ have been found.

  9. Effects on proprioception by Kinesio taping of the knee after anterior cruciate ligament rupture.

    Science.gov (United States)

    Bischoff, Lars; Babisch, Christian; Babisch, Jürgen; Layher, Frank; Sander, Klaus; Matziolis, Georg; Pietsch, Stefan; Röhner, Eric

    2018-03-10

    The use of Kinesio tape (KT) to improve proprioception is a matter of considerable debate. In comparison, the rupture of the anterior cruciate ligament is a sufficiently well-investigated injury with a proven compromise of proprioception. The objective of the present study was to assess a supportive effect on proprioception after KT application, taking the anterior cruciate ligament (ACL) rupture as an example. Forty-eight patients who had suffered an ACL rupture, confirmed clinically and by magnetic resonance imaging, and who were treated conservatively or were awaiting surgery were included in this study. In all patients, a gait analysis was performed on the affected leg before and after KT application. In addition, the IKDC score, the Lysholm score, stability using the Rolimeter, and the angle reproduction test were determined. Thirty-nine men and nine women who had had an ACL rupture for at least 3 weeks were included in the study. Significant improvements were achieved on the affected knee joint for the gait analysis parameters touchdown and unrolling, cadence, stability and stance phase as well as an extension of the hip joint. The Lysholm score improved from 79.3 to 85.8 (p < 0.001) and the IKDC score from 60.2 to 71.3 points (p < 0.001). Significant improvements were achieved in the Rolimeter and angle reproduction test. The use of KT has a positive effect on proprioception in patients with an anterior cruciate ligament rupture. Therefore, the application may improve gait pattern as well as the subjective function of the affected knee joint.

  10. Models of iodine behavior in reactor containments

    Energy Technology Data Exchange (ETDEWEB)

    Weber, C.F.; Beahm, E.C.; Kress, T.S.

    1992-10-01

    Models are developed for many phenomena of interest concerning iodine behavior in reactor containments during severe accidents. Processes include speciation in both gas and liquid phases, reactions with surfaces, airborne aerosols, and other materials, and gas-liquid interface behavior. Although some models are largely empirical formulations, every effort has been made to construct mechanistic and rigorous descriptions of relevant chemical processes. All are based on actual experimental data generated at the Oak Ridge National Laboratory (ORNL) or elsewhere, and, hence, considerable data evaluation and parameter estimation are contained in this study. No application or encoding is attempted, but each model is stated in terms of rate processes, with the intention of allowing mechanistic simulation. Taken together, this collection of models represents a best estimate iodine behavior and transport in reactor accidents.

  11. Models of iodine behavior in reactor containments

    International Nuclear Information System (INIS)

    Weber, C.F.; Beahm, E.C.; Kress, T.S.

    1992-10-01

    Models are developed for many phenomena of interest concerning iodine behavior in reactor containments during severe accidents. Processes include speciation in both gas and liquid phases, reactions with surfaces, airborne aerosols, and other materials, and gas-liquid interface behavior. Although some models are largely empirical formulations, every effort has been made to construct mechanistic and rigorous descriptions of relevant chemical processes. All are based on actual experimental data generated at the Oak Ridge National Laboratory (ORNL) or elsewhere, and, hence, considerable data evaluation and parameter estimation are contained in this study. No application or encoding is attempted, but each model is stated in terms of rate processes, with the intention of allowing mechanistic simulation. Taken together, this collection of models represents a best estimate iodine behavior and transport in reactor accidents

  12. Effects of cobalt on creep rupture properties and dislocation structures in nickel base superalloys

    International Nuclear Information System (INIS)

    Wang, W.Z.; Jin, T.; Jia, J.H.; Liu, J.L.; Hu, Z.Q.

    2015-01-01

    The influences of cobalt (Co) on creep rupture lives and dislocation structures in nickel base superalloys with and without rhenium (Re) are investigated. The creep rupture test conditions were high temperature low stress (1100 °C/150 MPa), intermediate temperature and stress (982 °C, 1010 °C) and low temperature high stress (850 °C/586 MPa). The results show that increasing Co content could enhance the creep rupture lives at low and intermediate temperature, and does not degrade the creep rupture lives of alloys at high temperature. In Re-containing alloys, at high temperature low stress (1100 °C/150 MPa), the effects of Co on the dislocation structures are negligible, while at low temperature high stress (850 °C/586 MPa), stacking faults are generated in alloy with 12% Co, and in alloy with 3% Co and free of Co, gamma prime particles are sheared by dislocation pairs. In Re-free alloys, at intermediate temperature and stress (1010 °C/248 MPa), large quantities of stacking faults appear in alloy without Co, while in alloy having 12% Co, gamma prime particles are sheared by dislocation pairs coupled by anti-phase boundary (APB). The gamma prime sheared by stacking faults or by dislocation pairs coupled by APB depends on the competition of stacking faults energy and APB energy which is affected by temperature and the interaction of Re and Co

  13. Bacteria Localization and Chorion Thinning among Preterm Premature Rupture of Membranes

    Science.gov (United States)

    Fortner, Kimberly B.; Grotegut, Chad A.; Ransom, Carla E.; Bentley, Rex C.; Feng, Liping; Lan, Lan; Heine, R. Phillips; Seed, Patrick C.; Murtha, Amy P.

    2014-01-01

    Objective Bacterial colonization of the fetal membranes and its role in pathogenesis of membrane rupture is poorly understood. Prior retrospective work revealed chorion layer thinning in preterm premature rupture of membranes (PPROM) subjects. Our objective was to prospectively examine fetal membrane chorion thinning and to correlate to bacterial presence in PPROM, preterm, and term subjects. Study Design Paired membrane samples (membrane rupture and membrane distant) were prospectively collected from: PPROM = 14, preterm labor (PTL = 8), preterm no labor (PTNL = 8), term labor (TL = 10), and term no labor (TNL = 8), subjects. Sections were probed with cytokeratin to identify fetal trophoblast layer of the chorion using immunohistochemistry. Fluorescence in situ hybridization was performed using broad range 16 s ribosomal RNA probe. Images were evaluated, chorion and choriodecidua were measured, and bacterial fluorescence scored. Chorion thinning and bacterial presence were compared among and between groups using Student's t-test, linear mixed effect model, and Poisson regression model (SAS Cary, NC). Results In all groups, the fetal chorion cellular layer was thinner at rupture compared to distant site (147.2 vs. 253.7 µm, prupture site compared to distant sites. In PPROM fetal chorion, we demonstrated pronounced global thinning. Although cause or consequence is uncertain, bacterial presence is greatest and inversely correlated with chorion thinning among PPROM subjects. PMID:24421883

  14. Hydrogen problems in reactor safety research

    International Nuclear Information System (INIS)

    Casper, H.

    1984-01-01

    The BMFT and BMI have initiated a workshop 'Hydrogen Problems in Reactor Safety Research' that took place October 3./4., 1983. The objective of this workshop was to present the state of the art in the main areas - Hydrogen-Production - Hydrogen-Distribution - Hydrogen-Ignition - Hydrogen-Burning and Containment Behaviour - Mitigation Measures. The lectures on the different areas are compiled. The most important results of the final discussion are summarized as well. (orig.) [de

  15. The rupture strength of dissimilar joints in high temperature

    International Nuclear Information System (INIS)

    Groenwall, B.

    1992-05-01

    In dissimilar joints between austenitic stainless steels and ferritic steels the heat affected zone in the ferritic steel always is the weakest link. Two different joints where the ferritic steel has been 10CrMo910 (2.25Cr1Mo) and X20CrMoV121 respectively (162Cr1Mo0.3V) has been investigated through thermal cycling and isothermal creep testing. In this case the purpose has been to investigate the weakest link and therefore both 10CrMo910 and X20CrMoV121 have been welded to themselves using the TIG-method with Inconel 82 (70Cr20Cr3Mn2). 5Nb as filler wire. Crossweld specimens have been taken from the joints. To accelerate the testing the tip temperature at thermal cycling and the temperature at isothermal creep testing has been in the region 600-650 degrees C. Low ductile fracture, which is typical for failures in practice, has been obtained by using a moderate tensile stress, 63 N/mm 2 . In the high temperature range, 650 degrees C, the thermal cycling compared to the isothermal testing had no influence but in lower temperatures the cycling caused decreased time to rupture. The time to rupture in thermal cycling as well as in isothermal testing as a function of testing temperature can be fitted to exponential curve of type t = a x e bT (where t and T are time and temperature respectively). Through extrapolation of the measured data it has been found that 10CrMo910 in hard conditions that is thermal cycling has a life time at 500 degrees C of about 100 000 h. If the operational temperature is constant the life time will be about four times longer. The X20CrMoV121 on the other hand has a life time at thermal cycling at 500 degrees C and moderate tensile stress of about 3 000 000 h. This means that the tensile stress can be increased considerably. The cracks appear in 10CrMo910 closely to the fusion line but in the X20CrMoV121 steel cracking and fracture arise in the heat affected zone some millimeters from the fusion line. (au)

  16. Assessment of Creep Deformation, Damage, and Rupture Life of 304HCu Austenitic Stainless Steel Under Multiaxial State of Stress

    Science.gov (United States)

    Sahoo, K. C.; Goyal, Sunil; Parameswaran, P.; Ravi, S.; Laha, K.

    2018-03-01

    The role of the multiaxial state of stress on creep deformation and rupture behavior of 304HCu austenitic stainless steel was assessed by performing creep rupture tests on both smooth and notched specimens of the steel. The multiaxial state of stress was introduced by incorporating circumferential U-notches of different root radii ranging from 0.25 to 5.00 mm on the smooth specimens of the steel. Creep tests were carried out at 973 K over the stress range of 140 to 220 MPa. In the presence of notch, the creep rupture strength of the steel was found to increase with the associated decrease in rupture ductility. Over the investigated stress range and notch sharpness, the strengthening was found to increase drastically with notch sharpness and tended toward saturation. The fractographic studies revealed the mixed mode of failure consisting of transgranular dimples and intergranular creep cavitation for shallow notches, whereas the failure was predominantly intergranular for relatively sharper notches. Detailed finite element analysis of stress distribution across the notch throat plane on creep exposure was carried out to assess the creep failure of the material in the presence of notch. The reduction in von-Mises stress across the notch throat plane, which was greater for sharper notches, increased the creep rupture strength of the material. The variation in fracture behavior of the material in the presence of notch was elucidated based on the von-Mises, maximum principal, and hydrostatic stresses. Electron backscatter diffraction analysis of creep strain distribution across the notch revealed localized creep straining at the notch root for sharper notches. A master curve for predicting creep rupture life under the multiaxial state of stress was generated considering the representative stress having contributions from both the von-Mises and principal stress components of the stress field in the notch throat plane. Rupture ductility was also predicted based on the

  17. Splenic rupture in a neonate – a rare complication

    African Journals Online (AJOL)

    differential diagnosis of a hypovolaemic shocked infant with an abdominal mass. The symptoms of splenic rupture are ... A diagnosis of splenic rupture due to possible birth trauma was made. The mother admitted a month later ... parenchyma, e.g. erythroblastosis fetalis and congenital syphilis, as an enlarged spleen is more ...

  18. Delayed splenic rupture presenting 70 days following blunt abdominal trauma.

    Science.gov (United States)

    Resteghini, Nancy; Nielsen, Jonpaul; Hoimes, Matthew L; Karam, Adib R

    2014-01-01

    Delayed splenic rupture following conservative management of splenic injury is an extremely rare complication. We report a case of an adult patient who presented with delayed splenic rupture necessitating splenectomy, 2 months following blunt abdominal trauma. Imaging at the initial presentation demonstrated only minimal splenic contusion and the patient was discharge following 24 hours of observation. © 2014.

  19. Frequency, predisposing factors and fetomaternal outcome in uterine rupture

    International Nuclear Information System (INIS)

    Malik, H.S.

    2006-01-01

    To determine the frequency and to analyze the predisposing factors, maternal and fetal outcome of uterine rupture. All cases of ruptured uterus, who were either admitted with or who developed this complication in the hospital, were included in the study. Demographic data, details regarding the most probable predisposing factor, type of rupture, the management and maternal and fetal outcome were taken into consideration for analysis.During three years, total number of deliveries was 18668, and there were 103 cases of uterine rupture (0.55%).Out of these, only 13 (12.62%) patients were booked. Most of the patients presented between the ages of 26-30 years (42.71%). Majority of ruptures occurred in para 2-4 (44.66%). Fifty five cases (53.39%) had a previous caesarean section scar. In 68 (66.01%) cases, the tear was located in lower uterine segment. In 93 (90.29%) cases, anterior uterine wall was involved. Rupture was complete in 79 (76.69%)cases. Repair of uterus was done in 79 (76.69%) cases. Hysterectomy was performed in 24 (23.30%) cases. There were 8 (7.76% or 77.66/1000) maternal deaths and 85 (81.73% or 825 / 1000) perinatal deaths.This study confirms high frequency of such serious preventable obstetrical problem which can lead to high fetomaternal mortality. Rupture of caesarean section scar was the most common cause of uterine rupture found in this series. (author)

  20. Unusual Cause of Acute Abdomen—Ruptured Retroperitoneal Paraganglioma

    OpenAIRE

    Kwok-Kay Yau; Wing-Tai Siu; Michael Ka-Wah Li

    2008-01-01

    Ruptured retroperitoneal paraganglioma is a rare cause of acute abdomen. Its clinical presentation and laparoscopic features have seldom been reported in the literature. Herein, we report a case of ruptured retroperitoneal paraganglioma that presented as acute abdomen, and its subsequent management.

  1. Unusual Cause of Acute Abdomen—Ruptured Retroperitoneal Paraganglioma

    Directory of Open Access Journals (Sweden)

    Kwok-Kay Yau

    2008-01-01

    Full Text Available Ruptured retroperitoneal paraganglioma is a rare cause of acute abdomen. Its clinical presentation and laparoscopic features have seldom been reported in the literature. Herein, we report a case of ruptured retroperitoneal paraganglioma that presented as acute abdomen, and its subsequent management.

  2. Ruptured uterus in Azare, north eastern Nigeria | Dattijo | Jos ...

    African Journals Online (AJOL)

    Background:-Ruptured uterus is an obstetric emergency and results in significant maternal and perinatal morbidity and mortality in Nigeria. The objective of the review is to determine the incidence, predisposing factors, maternal and foetal outcome in cases of ruptured uterus. Methods:- A 4-year retrospective review of ...

  3. Spontaneous Pre-Labour Rupture of Membranes at Term ...

    African Journals Online (AJOL)

    BACKGROUND: Spontaneous pre-labour rupture of membranes (SPROM) at term is one of the most common complications of pregnancy. It is an important cause of perinatal morbidity and mortality, particularly because it is associated with a latency period from membrane rupture to delivery. OBJECTIVE: To compare the ...

  4. Cutaneous Silicone Granuloma Mimicking Breast Cancer after Ruptured Breast Implant

    Directory of Open Access Journals (Sweden)

    Waseem Asim Ghulam El-Charnoubi

    2011-01-01

    Full Text Available Cutaneous manifestations due to migration of silicone from ruptured implants are rare. Migrated silicone with cutaneous involvement has been found in the chest wall, abdominal wall, and lower extremities. We describe a case of cutaneous silicone granuloma in the breast exhibiting unusual growth mimicking breast cancer after a ruptured implant.

  5. Unique case of esophageal rupture after a fall from height

    NARCIS (Netherlands)

    van Heijl, Mark; Saltzherr, Teun P.; van Berge Henegouwen, Mark I.; Goslings, J. Carel

    2009-01-01

    ABSTRACT: BACKGROUND: Traumatic ruptures of the esophagus are relatively rare. This condition is associated with high morbidity and mortality. Most traumatic ruptures occur after motor vehicle accidents. Case Presentation: We describe a unique case of a 23 year old woman that presented at our trauma

  6. Non‑bleeding Spontaneous Rupture of Hepatocellular Carcinoma

    African Journals Online (AJOL)

    split easily when the vascular load increases from hypertension or minor trauma is another hypothesis for of HCC ruptures.[6]. Abdominal pain is the only independent factor relating to rupture of HCC.[7] Doppler ultrasound and computer tomography (CT) scan are useful to exclude of hemoperitoneum and evaluation.

  7. Delayed primary realignment of posterior urethral rupture | Shittu ...

    African Journals Online (AJOL)

    The treatment of acute posterior urethral rupture is controversial. Twelve patients who presented with acute posterior urethral rupture over a five--year period were treated by delayed primary realignment of the injury. The technique of this procedure and the outcome are the subject of this presentation. Eight patients had ...

  8. Traumatic rupture of the diaphragm | Jamabo | Sahel Medical Journal

    African Journals Online (AJOL)

    Those treated for traumatic rupture of the diaphragm were selected and analyzed for age, gender, cause of injury, associated injuries sustained and mode of treatment. They were all treated at the University of Port Harcourt Teaching Hospital and a private clinic in Port Harcourt. Results: 12 patients had traumatic rupture of ...

  9. Tetraventricular hydrocephalus due to ruptured intracranial dermoid cyst

    International Nuclear Information System (INIS)

    Karabulut, N.; Oguzkurt, L.

    2000-01-01

    We present the MR imaging findings in a patient who developed tetraventricular hydrocephalus after massive rupture of dermoid cysts with generalized subarachnoid and ventricular spread of cyst contents. The development of tetraventricular hydrocephalus due to ruptured dermoid is a very unusual complication, and was attributed to cyst contents interfering with passage of cerebrospinal fluid through the arachnoid granulations and fourth ventricular outlet foramina. (orig.)

  10. Spontaneous calyceal rupture caused by a ureteral calculus ...

    African Journals Online (AJOL)

    Rupture of the urinary collecting system with perirenal and retroperitoneal extravasation of the urine is an unusual condition that is typically caused by ureteral-obstructing calculi. We report a case of calyceal rupture with urinoma formation, due to a stone in the distal ureter. The diagnosis was confirmed by computed ...

  11. Spontaneous calyceal rupture caused by a ureteral calculus

    African Journals Online (AJOL)

    A. Chaabouni

    Ureteral calculus;. CT;. Ureterel stent. Abstract. Rupture of the urinary collecting system with perirenal and retroperitoneal extravasation of the urine is an unusual condition that is typically caused by ureteral-obstructing calculi. We report a case of calyceal rupture with urinoma formation, due to a stone in the distal ureter.

  12. Antibiotics after preterm premature rupture of the membranes.

    Science.gov (United States)

    Singh, Katherine; Mercer, Brian

    2011-06-01

    Preterm premature rupture of the membranes remains a common cause of preterm deliveries and neonatal morbidities. The goal of this study is to review the evidence with regard to the antibiotic treatment after preterm premature rupture of the membranes, long-term outcomes related to antibiotic treatment, and possible complications with treatment. Future research goals are also discussed.

  13. Spontaneous gastric rupture after Sodium Bicarbonate consumption: A case report.

    Science.gov (United States)

    Vásquez, A; Domínguez, C; Perdomo, C F

    2017-08-01

    Spontaneous gastric rupture is a rare condition however a prompt diagnosis and treatment are necessary to decrease mortality and morbidity. We report a case of stomach rupture after the ingestion of Sodium Bicarbonate (SB); imaging findings with a brief review of the literature are presented. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  14. Rupture model based on non-associated plasticity

    Science.gov (United States)

    Pradeau, Adrien; Yoon, Jeong Whan; Thuillier, Sandrine; Lou, Yanshan; Zhang, Shunying

    2018-05-01

    This research work is about modeling the mechanical behavior of metallic sheets of AA6016 up to rupture using non-associated flow rule. Experiments were performed at room temperature in uniaxial tension and simple shear in different directions according to the rolling direction and an additional hydraulic bulge test. The anisotropy of the material is described by a Yld2000-2d yield surface [1], calibrated by stress ratios, and a plastic potential represented by Hill1948 [2], calibrated using Lankford coefficients. That way, the former is able to reproduce the yield stresses in different directions and the latter is able to reproduce the deformations in different directions as well [3], [4]. Indeed, the non-associated flow rule allows for the direction of the plastic flow not to be necessarily normal to the yield surface. Concerning the rupture, the macroscopic ductile fracture criterion DF2014 was used [5]. It indirectly uses the three invariants of the stress tensor by using the three following parameters: the stress triaxiality η, the Lode parameter L and the equivalent plastic strain to fracture ∈f-p . In order to be consistent with the plastic model and to add more flexibility to the p criterion, the equivalent stress σ ¯ and the equivalent strain to fracture ∈f-p have been substituted respectively as Yld2000-2d and Hill1948 in the DF2014 fracture criterion. The parameters for the fracture criterion were obtained by optimization and the fracture locus can be plotted in the (η ,L ,∈-p) space. The damage indicator D is then numerically predicted with respect of average strain values. A good correlation with the experimental results is obtained.

  15. Hemothorax caused by spontaneous rupture of hepatocellular carcinoma in the pleural cavity: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hin Hee; Ohm, Joon Young [Dept. of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of); Kim, Song Soo; Kim, Jin Hwan [Dept. of Radiology, Chungnam National University School of Medicine, Daejeon(Korea, Republic of)

    2017-07-15

    Hemothorax resulting from ruptured hepatocellular carcinoma (HCC) is extremely rare and is generally caused by ruptured intrathoracic metastatic lesions. However, we report a rare case of hemothorax resulting from intrathoracic rupture of primary HCC.

  16. Multi-Fault Rupture Scenarios in the Brawley Seismic Zone

    Science.gov (United States)

    Kyriakopoulos, C.; Oglesby, D. D.; Rockwell, T. K.; Meltzner, A. J.; Barall, M.

    2017-12-01

    Dynamic rupture complexity is strongly affected by both the geometric configuration of a network of faults and pre-stress conditions. Between those two, the geometric configuration is more likely to be anticipated prior to an event. An important factor in the unpredictability of the final rupture pattern of a group of faults is the time-dependent interaction between them. Dynamic rupture models provide a means to investigate this otherwise inscrutable processes. The Brawley Seismic Zone in Southern California is an area in which this approach might be important for inferring potential earthquake sizes and rupture patterns. Dynamic modeling can illuminate how the main faults in this area, the Southern San Andreas (SSAF) and Imperial faults, might interact with the intersecting cross faults, and how the cross faults may modulate rupture on the main faults. We perform 3D finite element modeling of potential earthquakes in this zone assuming an extended array of faults (Figure). Our results include a wide range of ruptures and fault behaviors depending on assumptions about nucleation location, geometric setup, pre-stress conditions, and locking depth. For example, in the majority of our models the cross faults do not strongly participate in the rupture process, giving the impression that they are not typically an aid or an obstacle to the rupture propagation. However, in some cases, particularly when rupture proceeds slowly on the main faults, the cross faults indeed can participate with significant slip, and can even cause rupture termination on one of the main faults. Furthermore, in a complex network of faults we should not preclude the possibility of a large event nucleating on a smaller fault (e.g. a cross fault) and eventually promoting rupture on the main structure. Recent examples include the 2010 Mw 7.1 Darfield (New Zealand) and Mw 7.2 El Mayor-Cucapah (Mexico) earthquakes, where rupture started on a smaller adjacent segment and later cascaded into a larger

  17. Spontaneous atraumatic extensor pollicis longus rupture in the nonrheumatoid population.

    Science.gov (United States)

    Rada, Erin M; Shridharani, Sachin M; Lifchez, Scott D

    2013-01-01

    Extensor pollicis longus (EPL) tendon rupture is a well-described phenomenon in patients with rheumatoid arthritis. Mechanisms of EPL tendon rupture in the nonrheumatoid population have also been described and include traumatic rupture, repetitive motion strain, and steroid injection into the tendon. The operative records for patients undergoing extensor pollicis longus reconstruction by the senior author were reviewed. Patients with a history of trauma to the wrist or inflammatory arthropathy were excluded. We identified 3 patients who presented with spontaneous EPL tendon rupture. These patients reported no risk factors (as listed earlier) or inciting event. All 3 patients had some exposure to local steroids but this exposure was not at the site of subsequent tendon rupture. All patients were operatively repaired and went on to full recovery of EPL function. In patients with sudden loss of extension of the thumb interphalangeal joint, a thorough history of steroid exposure including local steroid exposure remote to the affected EPL tendon may be relevant.

  18. Incidence of plantar fascia ruptures following corticosteroid injection.

    Science.gov (United States)

    Kim, Chul; Cashdollar, Michael R; Mendicino, Robert W; Catanzariti, Alan R; Fuge, LaDonna

    2010-12-01

    Plantar fasciitis is commonly treated with corticosteroid injections to decrease pain and inflammation. Therapeutic benefits often vary in terms of efficacy and duration. Rupture of the plantar fascia has been reported as a possible complication following corticosteroid injection. A retrospective chart review of 120 patients who received corticosteroid injection for plantar fasciitis was performed at the authors' institution to determine the incidence of plantar fascia rupture. The plantar fascia rupture was diagnosed clinically and confirmed with magnetic resonance imaging. Various factors were analyzed, including the number of injections, interval between injections, body mass index (BMI), and activity level. Four patients (2.4%) consequently experienced plantar fascia rupture following an average of 2.67 injections. The average BMI of these patients was 38.6 kg/m². The authors conclude that corticosteroid injection therapy appears to be a safe and effective form of nonoperative treatment with minimal complications and a relatively low incident of plantar fascia rupture.

  19. Rupture of the urinary bladder after minimal trauma

    International Nuclear Information System (INIS)

    Myrseth, L.E.; Johansen, T.E.B.

    1991-01-01

    Rupture of the urinary bladder is a rare injury most often encountered after severe trauma and in conjunction with injuries to other organ systems. It may occur, however, without concomitant injury and also after minimal trauma. This diagnosis must be suspected in a patient with abdominal pain who is unable to void or who presents hematuria. The diagnosis is made by means of a retrograde cystogram using 350-400 ml contrast medium and supplemented by a drainage film. Intrapertioneal ruptures should be treated surgically by closure in layers, and drainage. Patients with extraperitoneal ruptures can safely be treated with simple catheter drainage until the rupture has healed, usually within 10-20 days. The authors report three cases of bladder rupture after minimal trauma and describe the state of the art of diagnosis and treatment of these injuries. 15 refs., 3 figs

  20. Radioactivity transport following steam generator tube rupture

    International Nuclear Information System (INIS)

    Hopenfeld, J.

    1985-03-01

    A review of the capabilities of the CITADEL computer code as well as plant experience to project radioactivity releases following a steam generator tube rupture in PWR's shows that certain experimental data are needed for reliable off-site dose predictions. This article defines five parameters which are the key for such predictions and discusses the functional dependence of these parameters on various operational variables. The above parameters can be used in conjunction with CITADEL or they can be inserted in the appropriate equations which then conveniently can be programmed as a subroutine in thermal-hydraulic system codes. A joint Westinghouse, Electric Power Research Institute and Nuclear Regulatory Commission Program aimed at obtaining the five parameters empirically is described

  1. Proposed new mechanism of traumatic aortic rupture

    International Nuclear Information System (INIS)

    Crass, J.R.; Cohen, A.M.; Motta, A.O.; Tomashefski, J.F.; Wiesen, E.

    1990-01-01

    The currently accepted mechanism to explain traumatic aortic rupture from rapid deceleration invokes a combination of traction, torsion, and hydrostatic forces. None of these forces individually is of adequate magnitude to result in aortic disruption. This paper proposes a theory, that aortic lacerations result from a pinch of the aorta between the spine and the anterior bony thorax during the chest compression caused by abrupt deceleration. Three sets of experiments were performed. Geometric analysis of CT images and compression of an articulated skeleton were performed to assess where the anterior and posterior osseous structures would contact if maximally compressed. Fresh dog aortas were pinched in a manner that would mimic the manubrium impacting the spine. Finally, attempts were made to tear an aorta via traction and torsion (whiplash)

  2. Hepatic echinococcosis ruptured into the biliary tract

    International Nuclear Information System (INIS)

    Van Steenbergen, W.; Fevery, J.; Broeckaert, L.; Ponette, E.; Marchal, G.; Baert, A.; Penninckx, F.; Kerremans, R.; De Groote, J.

    1987-01-01

    Three patients are described with hepatic involvement by Echinococcus granulosus, complicated by spontaneous rupture into the biliary tract. Abdominal computed tomography, showing the cystic wall, the presence of wall calcifications, daughter cysts and wall enhancement, provided a correct diagnosis of hepatic hydatidosis in all patients. Dilatation of the bile ducts with the presence of intraluminal material was clearly shown by sonography and endoscopic retrograde cholangiography. On sonography, the intraluminal material appeared as amorphous, sludge-like hydatid sand, and as daughter cysts. On ERCP, the intrabiliary parasitic material appeared as non-homogeneous, irregularly shaped and mobile filling defects. Other findings at ERCP were displacement and distortion of intrahepatic bile ducts by the hepatic cysts and a mild dilatation of the pancreatic duct. (Auth.)

  3. Powered AFO for Achilles tendon rupture.

    Science.gov (United States)

    Yoshizawa, Nobuyuki

    2008-01-01

    This paper proposes a powered ankle foot orthosis (AFO) for the treatment of a ruptured Achilles tendon. Usually, conservative orthosis treatment requires about two months, and a motionless ankle degrades activities of daily living (ADL). It is difficult to go to school or work on foot, and a pair of crutches is needed to go up and down stairs. In order to improve the ADL, an electric powered AFO has been designed to improve the ability to walk with a fixed ankle joint. The sole of the proposed AFO is equipped with an electric actuator. The prototype actuator consists of Nd magnets and electromagnets and is lightweight and battery driven. The actuator can switch the upright posture and the stepped forward posture of the patient. In an experiment, the use of this electric AFO made it possible to walk and to ascend and descend stairs with a fixed ankle joint.

  4. Imaging of diaphragmatic rupture after trauma

    International Nuclear Information System (INIS)

    Eren, S.; Kantarci, M.; Okur, A.

    2006-01-01

    Traumatic rupture of the diaphragm usually results from blunt or penetrating injuries, or iatrogenic causes. Most cases are initially overlooked in the acute phase because they present with variable clinical and radiological signs. An overlooked diaphragmatic injury presents as a hernia many years later with potentially serious complications, therefore selection of the most appropriate radiological technique and accurate diagnosis of traumatic diaphragmatic hernias (DH) on the first admission is important. Although the diagnosis of diaphragmatic injuries is problematic, various investigations may be used for diagnosis. We describe the imaging findings of 19 traumatic DH cases with various imaging techniques. The patients were acute trauma cases or cases with prior trauma or thoraco-abdominal surgery with clinical suspicion of DH. An evaluation of the imaging techniques used in the diagnosis of DH is presented

  5. Can Severe Kyphoscoliosis Lead to Aorta Rupture?

    Science.gov (United States)

    Kotopoulos, Constantinos; Karakasi, Maria Valeria; Kapetanakis, Stylianos; Pavlidis, Pavlos

    2016-09-01

    Neurofibromatosis type 1 is a polysystemic disease presenting with a multifaceted clinical picture. Clinical manifestations may present in the skin, as well as in the skeletal and cardiovascular system. The present study aims to describe and examine the case of a 46-year-old woman, who suffered from neurofibromatosis type 1 and died abruptly in the emergency room. The forensic examination attributed her death to traumatic rupture of the thoracic aorta resulting from an acute angulation that her vertebral column formed in the thoracic region (severe kyphosis). Outspread cutaneous neurofibromas, severe scoliosis, and osteoporosis (brittle bones) were observed during the autopsy. No atherosclerotic lesions were detected in the aortic lumen. To the authors' knowledge, no similar case has been reported throughout relevant literature.

  6. Risk factors of recurrent anal sphincter ruptures

    DEFF Research Database (Denmark)

    Jangö, Hanna; Langhoff-Roos, J; Rosthøj, Steen

    2012-01-01

    Please cite this paper as: Jangö H, Langhoff-Roos J, Rosthøj S, Sakse A. Risk factors of recurrent anal sphincter ruptures: a population-based cohort study. BJOG 2012;00:000-000 DOI: 10.1111/j.1471-0528.2012.03486.x. Objective  To determine the incidence and risk factors of recurrent anal sphincter...... were used to determine risk factors of recurrent ASR. Main outcome measures  The incidence of recurrent ASR and odds ratios for possible risk factors of recurrent ASR: age, body mass index, grade of ASR, birthweight, head circumference, gestational age, presentation, induction of labour, oxytocin...... augmentation, epidural, episiotomy, vacuum extraction, forceps, shoulder dystocia, delivery interval and year of second delivery. Results  Out of 159 446 women, 7336 (4.6%) experienced an ASR at first delivery, and 521 (7.1%) had a recurrent ASR (OR 5.91). The risk factors of recurrent ASR in the multivariate...

  7. The diagnostic value of the lactate level in the vaginal fluid for determining the premature rupture of membranes

    International Nuclear Information System (INIS)

    Ahmadi, M.; Rafaei, F.; Nazari, N.

    2013-01-01

    Objectives:To determine the diagnostic value of the lactate concentration in vaginal secretions in determining the premature rupture of membranes. Subjects and Methods:One hundred 100 pregnant women with single pregnancy of gestational age 20--41 weeks were divided to two groups of 50 each. One group comprised of women with premature rupture of membranes, and the other (control group) of women with intact membranes. To verify the premature rupture of membranes in both groups, the speculum, fern, and nitrazine tests were done. Lactate Pro manual instrument was used to measure the lactate levels in vaginal fluid via enzymatic staining which was displayed on the instrument's liquid crystal display after 60 seconds. Descriptive analytic statistics and SPSS 17 software were used to analyze the data. Results The lactate concentration of 4.6 mM in the vaginal fluid was diagnostic for premature rupture of membranes. It had a sensitivity of 96%, specificity of 98.8%, accuracy of 97%, positive predictive value of 97.9%, and negative predictive value of 96%. Conclusions:Testing lactate levels in the vaginal fluid is an easy, rapid and reliable method for the diagnosis of premature rupture of membranes in pregnancy. (author)

  8. Improvement in the long term creep rupture strength of SUS 316 steel for fast breeder reactors by nitrogen addition

    International Nuclear Information System (INIS)

    Nakazawa, Takanori; Abo, Hideo; Tanino, Mitsuru; Komatsu, Hazime; Tashimo, Masanori; Nishida, Takashi.

    1989-01-01

    Improvement of creep fatigue property of structural materials for fast breeder reactors. In order to improve the resistance to creep fatigue of SUS 316 steels, the effects of nitrogen, carbon, and molybdenum on creep properties have been investigated, under the concept that creep fatigue endurance is correspond to creep rupture ductility. Creep rupture tests and slow strain rate tensile tests were conducted at 550degC and extensive microstructural works were performed. The strengthening by nitrogen is much greater than carbon. Moreover, while carbon reduces rupture ductility, nitrogen does not change it. The addition of carbon results in coarse carbide formation on grain boundaries during creep, but with nitrogen very fine Fe 2 Mo particles precipitate on grain boundaries. The difference between the effects of nitrogen and carbon on creep properties is arise from the different morphology of precipitation. Strengthening by molybdenum brings about a slight decrease in rupture ductility. On the basis of these results, 0.01%C-0.07%N-11%Ni-16.5%Cr-2%Mo steel is selected as a promising material for fast breeder reactors. This steel has higher rupture ductility and strength than SUS 316 steel. It is also confirmed that this steel has a higher resistance to creep fatigue. (author)

  9. Analysis of the dynamic response of a double rupture disc assembly to simulated sodium-water reaction pressure pulses

    International Nuclear Information System (INIS)

    Leonard, J.R.

    1980-03-01

    A series of double rupture disc experiments were conducted in 1979 to evaluate the dynamic response characteristics of this pressure relief apparatus. The tests were performed in a facility with water simulating sodium and rising pressure pulses representative of the pressure increase resulting from a water/steam leak from a steam generator into sodium in the intermediate heat transport system of a breeder reactor power plant. Maximum source pressures ranged in magnitude from 50 psi to 800 psi. Dynamic response characteristics of each of the two rupture discs were similar to those observed in larger scale sodium-water experiments conducted in the Series I and Series II Large Leak Test Program at the Energy Technology Engineering Center. The SRI double rupture disc dynamic behavior was found to be consistent and amendable to modelling in the TRANSWRAP II computer code. A series of correlations which represent rupture disc buckling parameters were developed for use in the TRANSWRAP II code. The semi-empirical modeling of the rupture discs in the TRANSWRAP II code showed very good agreement with the experimental results

  10. Comparison of extrapolation methods for creep rupture stresses of 12Cr and 18Cr10NiTi steels

    International Nuclear Information System (INIS)

    Ivarsson, B.

    1979-01-01

    As a part of a Soviet-Swedish research programme the creep rupture properties of two heat resisting steels namely a 12% Cr steel and an 18% Cr12% Ni titanium stabilized steel have been studied. One heat from each country of both steels were creep tested. The strength of the 12% Cr steels was similar to earlier reported strength values, the Soviet steel being some-what stronger due to a higher tungsten content. The strength of the Swedish 18/12 Ti steel agreed with earlier results, while the properties of the Soviet steel were inferior to those reported from earlier Soviet creep testings. Three extrapolation methods were compared on creep rupture data collected in both countries. Isothermal extrapolation and an algebraic method of Soviet origin gave in many cases rather similar results, while the parameter method recommended by ISO resulted in higher rupture strength values at longer times. (author)

  11. Dynamic rupture analysis of reinforced concrete shells

    International Nuclear Information System (INIS)

    Rebora, B.; Zimmermann, Th.; Wolf, J.P.

    1976-01-01

    Extreme dynamic loading conditions often require the rupture analysis of reinforced and prestressed-concrete structures. The study presented in this paper extends a method of analysis of dynamic loading conditions which has proven efficient for short-time loads. Another aim is to adapt the method to thin-walled structures. It is not sufficient to work only with plastic rupture and yield surfaces locally which are compared to the elastic distribution of the stress resultants; it is essential to account for the redistribution of the latter. The method proposed consists of discretizing the structure into isoparametric three-dimensional elements with 20 nodes for the concrete and one-dimensional bar elements with three nodes for the steel. The latter can also be handled with a 'smeared' two-dimensional membrane element. In compression a three-dimensional non-linear elastic constitutive law is introduced for the concrete, and a triaxial failure surface expressed in the stress invariants is used, determining cracking and crushing. Two- and three-dimensional cracking surfaces in which no components of stress are transmitted are accounted for. The possibility exists that, during the history of loading, cracks can close up again. For steel, a yield criterion is selected. The non-linear analysis is based on the concept of initial stress. Residual loads are calculated using information in Gauss integration points. The ultimate load is reached when the algorithm does not converge. The corresponding failure modes can be interpreted as those for which a state of equilibrium is no longer possible. The equations of motion are discretized in time, using an extension of the linear acceleration method. (Auth.)

  12. CFD modeling of a boiler's tubes rupture

    International Nuclear Information System (INIS)

    Rahimi, Masoud; Khoshhal, Abbas; Shariati, Seyed Mehdi

    2006-01-01

    This paper reports the results of a study on the reason for tubes damage in the superheater Platen section of the 320 MW Bisotoun power plant, Iran. The boiler has three types of superheater tubes and the damage occurs in a series of elbows belongs to the long tubes. A three-dimensional modeling was performed using an in-house computational fluid dynamics (CFD) code in order to explore the reason. The code has ability of simultaneous solving of the continuity, the Reynolds-Averaged Navier-Stokes (RANS) equations and employing the turbulence, combustion and radiation models. The whole boiler including; walls, burners, air channels, three types of tubes, etc., was modeled in the real scale. The boiler was meshed into almost 2,000,000 tetrahedral control volumes and the standard k-ε turbulence model and the Rosseland radiation model were used in the model. The theoretical results showed that the inlet 18.9 MPa saturated steam becomes superheated inside the tubes and exit at a pressure of 17.8 MPa. The predicted results showed that the temperature of the steam and tube's wall in the long tubes is higher than the short and medium size tubes. In addition, the predicted steam mass flow rate in the long tube was lower than other ones. Therefore, it was concluded that the main reason for the rupture in the long tubes elbow is changing of the tube's metal microstructure due to working in a temperature higher than the design temperature. In addition, the structural fatigue tension makes the last elbow of the long tube more ready for rupture in comparison with the other places. The concluded result was validated by observations from the photomicrograph of the tube's metal samples taken from the damaged and undamaged sections

  13. The effect of vacuum environment on creep rupture properties of Inconel 617 at 1000 deg C

    International Nuclear Information System (INIS)

    Ohnami, Masateru; Imamura, Riuzo

    1981-01-01

    The creep rupture strength of nickel-base superalloy in weakly acidic gas at high temperature above 1000 deg C lowers remarkably as compared with that in the atmosphere, and this problem is one of the important subjects in connection with the research and development of high temperature heat exchangers for multi-purpose high temperature gas-cooled reactor system being developed in Japan. In the case of Inconel 617, abnormal decarbonization phenomenon occurs in weakly acidic gas, and this is regarded as the cause of lowering the creep strength. In this study, the effects of the decarbonization in weak vacuum at 1000 deg C and the oxidation of Inconel 617 on its crack occurrence and propagation were clarified experimentally with notched plate test pieces. The material used was Inconel 617 nickel-base superalloy made by Huntington Alloys Inc. in the U.S. The creep rupture experiment was carried out with a simple tension creep tester. At the nominal stress of 3.5 kg/mm 2 , the creep rupture time in 0.3 Torr was the shortest when the grain size was 78 μm, and the creep rupture time increased as the grain size became larger. The creep rupture time in 0.3 Torr decreased to a half of that in the atmosphere. In 0.3 Torr, cracks occurred early, and propagated fast as compared with in the atmosphere. This is because the local creep velocity at the bottom of notches and in front of creep cracks is fast owing to the lack of protective oxide film. (Kako, I.)

  14. Microstructure-based assessment of creep rupture behaviour of cast-forged P91 steel

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Chandan, E-mail: chandanpy.1989@gmail.com [Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Uttrakhand 247667 (India); Mahapatra, M.M. [School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Odisha 751013 (India); Kumar, Pradeep; Vidyrathy, R.S. [Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Uttrakhand 247667 (India); Srivastava, A. [Senior Engineer, HEEP Section, BHEL Haridwar (India)

    2017-05-17

    The work presented in this study was performed with the intent to characterize the microstructure evolution for short term creep exposure of cast-forged P91 steel. The short-term creep test was performed at temperature range of 620–650 °C and stresses ranging from 120 to 200 MPa. To characterize the sample after creep exposure, field emission scanning electron microscopy (FESEM) with energy dispersive X-ray spectroscopy (EDS), optical microscope and micro-hardness testing were utilized. Creep tests were performed on round creep specimens. For low temperature service condition, longer creep life was obtained. The fracture surface of creep ruptured specimen were characterized by using the FESEM. The transgranular fracture mode was noticed in all the tests condition. The creep rupture life was found to be decreased with increase in applied stress. The maximum rupture life was measured about to be 3329.28 h for the sample exposed at 620 °C for 120 MPa. A negligible microstructural change was measured in gripping area compared to the gauge area (necking area) of crept sample. The laves phase formation was also noticed along the grain boundaries for creep exposure life of 3329.28 h.

  15. Microstructure-based assessment of creep rupture behaviour of cast-forged P91 steel

    International Nuclear Information System (INIS)

    Pandey, Chandan; Mahapatra, M.M.; Kumar, Pradeep; Vidyrathy, R.S.; Srivastava, A.

    2017-01-01

    The work presented in this study was performed with the intent to characterize the microstructure evolution for short term creep exposure of cast-forged P91 steel. The short-term creep test was performed at temperature range of 620–650 °C and stresses ranging from 120 to 200 MPa. To characterize the sample after creep exposure, field emission scanning electron microscopy (FESEM) with energy dispersive X-ray spectroscopy (EDS), optical microscope and micro-hardness testing were utilized. Creep tests were performed on round creep specimens. For low temperature service condition, longer creep life was obtained. The fracture surface of creep ruptured specimen were characterized by using the FESEM. The transgranular fracture mode was noticed in all the tests condition. The creep rupture life was found to be decreased with increase in applied stress. The maximum rupture life was measured about to be 3329.28 h for the sample exposed at 620 °C for 120 MPa. A negligible microstructural change was measured in gripping area compared to the gauge area (necking area) of crept sample. The laves phase formation was also noticed along the grain boundaries for creep exposure life of 3329.28 h.

  16. Creep and rupture of an ODS alloy with high stress rupture ductility. [Oxide Dispersion Strengthened

    Science.gov (United States)

    Mcalarney, M. E.; Arsons, R. M.; Howson, T. E.; Tien, J. K.; Baranow, S.

    1982-01-01

    The creep and stress rupture properties of an oxide (Y2O3) dispersion strengthened nickel-base alloy, which also is strengthened by gamma-prime precipitates, was studied at 760 and 1093 C. At both temperatures, the alloy YDNiCrAl exhibits unusually high stress rupture ductility as measured by both elongation and reduction in area. Failure was transgranular, and different modes of failure were observed including crystallographic fracture at intermediate temperatures and tearing or necking almost to a chisel point at higher temperatures. While the rupture ductility was high, the creep strength of the alloy was low relative to conventional gamma prime strengthened superalloys in the intermediate temperature range and to ODS alloys in the higher temperature range. These findings are discussed with respect to the alloy composition; the strengthening oxide phases, which are inhomogeneously dispersed; the grain morphology, which is coarse and elongated and exhibits many included grains; and the second phase inclusion particles occurring at grain boundaries and in the matrix. The creep properties, in particular the high stress dependencies and high creep activation energies measured, are discussed with respect to the resisting stress model of creep in particle strengthened alloys.

  17. A three-dimensional rupture analysis of steel liners anchored to concrete pressure and containment vessels

    International Nuclear Information System (INIS)

    Bangash, Y.

    1987-01-01

    Steel liners or plates are anchored to concrete pressure and containment vessels for nuclear and offshore facilities. Due to extreme loading conditions a liner may buckle due to the pull-out or shearing of anchors from the base metal and concrete. Under certain conditions attributed to loadings, liner metal deterioration and cracking of concrete behind the liner, the liner may fail by rupture. This paper presents a three-dimensional analysis of steel-concrete elements, using finite elements analysis in which a provision is made for liner instability, anchor strength and stiffness, concrete cracking and finally liner rupture. The analysis is tested first on an octagonal slab with and without an anchored steel liner. It is then extended to concrete pressure and containment vessels. The analytical results obtained are compared well with those available from the experimental tests and other sources. (author)

  18. Creep deformation and rupture behavior of type 304/308 stainless steel structural weldments

    International Nuclear Information System (INIS)

    McAfee, W.J.; Richardson, M.; Sartory, W.K.

    1977-01-01

    The creep deformation and rupture of type 304/308 stainless steel structural weldments at 593 0 C (1100 0 F) was experimentally investigated to study the comparative behavior of the base metal and weld metal constituents. The tests were conducted in support of ORNL's program to develop high-temperature structural design methods applicable to liquid-metal fast breeder reactor (LMFBR) system components that operate in the creep range. The specimens used were thin-walled, right circular cylinders capped with either flat or hemispherical heads and tested under internal gas pressure. Circumferential welds were located in different regions of the cylinder or head and, with one exception, were geometrically duplicated by all base metal regions in companion specimens. Results are presented on the comparative deformation and rupture behavior of selected points in the base metal and weldment regions of the different specimens and on the overall surface strains for selected specimens

  19. Effects on stress rupture life and tensile strength of tin additions to Inconel 718

    Science.gov (United States)

    Dreshfield, R. L.; Johnson, W.

    1982-01-01

    Because Inconel 718 represents a major use of columbium and a large potential source of columbium for aerospace alloys could be that of columbium derived from tin slags, the effects of tin additions to Inconel 718 at levels which might be typical of or exceed those anticipated if tin slag derived columbium were used as a melting stock were investigated. Tin was added to 15 pound Inconel 718 heats at levels varying from none added to approximately 10,000 ppm (1 wt%). Limited 1200 F stress rupture testing was performed at stresses from 68,000 to 115,000 psi and a few tensile tests were performed at room temperature, 800 and 1200 F. Additions of tin in excess of 800 ppm were detrimental to ductility and stress rupture life.

  20. Fault geometry, rupture dynamics and ground motion from potential earthquakes on the North Anatolian Fault under the Sea of Marmara

    KAUST Repository

    Oglesby, David D.

    2012-03-01

    Using the 3-D finite-element method, we develop dynamic spontaneous rupture models of earthquakes on the North Anatolian Fault system in the Sea of Marmara, Turkey, considering the geometrical complexity of the fault system in this region. We find that the earthquake size, rupture propagation pattern and ground motion all strongly depend on the interplay between the initial (static) regional pre-stress field and the dynamic stress field radiated by the propagating rupture. By testing several nucleation locations, we observe that those far from an oblique normal fault stepover segment (near Istanbul) lead to large through-going rupture on the entire fault system, whereas nucleation locations closer to the stepover segment tend to produce ruptures that die out in the stepover. However, this pattern can change drastically with only a 10° rotation of the regional stress field. Our simulations also reveal that while dynamic unclamping near fault bends can produce a new mode of supershear rupture propagation, this unclamping has a much smaller effect on the speed of the peak in slip velocity along the fault. Finally, we find that the complex fault geometry leads to a very complex and asymmetric pattern of near-fault ground motion, including greatly amplified ground motion on the insides of fault bends. The ground-motion pattern can change significantly with different hypocentres, even beyond the typical effects of directivity. The results of this study may have implications for seismic hazard in this region, for the dynamics and ground motion of geometrically complex faults, and for the interpretation of kinematic inverse rupture models.

  1. Fault geometry, rupture dynamics and ground motion from potential earthquakes on the North Anatolian Fault under the Sea of Marmara

    KAUST Repository

    Oglesby, David D.; Mai, Paul Martin

    2012-01-01

    Using the 3-D finite-element method, we develop dynamic spontaneous rupture models of earthquakes on the North Anatolian Fault system in the Sea of Marmara, Turkey, considering the geometrical complexity of the fault system in this region. We find that the earthquake size, rupture propagation pattern and ground motion all strongly depend on the interplay between the initial (static) regional pre-stress field and the dynamic stress field radiated by the propagating rupture. By testing several nucleation locations, we observe that those far from an oblique normal fault stepover segment (near Istanbul) lead to large through-going rupture on the entire fault system, whereas nucleation locations closer to the stepover segment tend to produce ruptures that die out in the stepover. However, this pattern can change drastically with only a 10° rotation of the regional stress field. Our simulations also reveal that while dynamic unclamping near fault bends can produce a new mode of supershear rupture propagation, this unclamping has a much smaller effect on the speed of the peak in slip velocity along the fault. Finally, we find that the complex fault geometry leads to a very complex and asymmetric pattern of near-fault ground motion, including greatly amplified ground motion on the insides of fault bends. The ground-motion pattern can change significantly with different hypocentres, even beyond the typical effects of directivity. The results of this study may have implications for seismic hazard in this region, for the dynamics and ground motion of geometrically complex faults, and for the interpretation of kinematic inverse rupture models.

  2. Pt-Rh alloys. Investigation of creep rate and rupture time at high temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Trumic, Biserka; Gomidzelovic, Lidija; Marjanovic, Sasa; Ivanovic, Aleksandra; Dimitrijevic, Silvana [Belgrade Univ., Bor (Serbia). Inst. of Mining and Metallurgy; Krstic, Vesna

    2013-02-01

    The results of experimental investigation of creep rate and rupture time of the alloys of Pt-Rh system are presented in this paper. Selected alloys with 7-40 wt.-% Rh content were examined using a universal device for tensile testing of materials at high temperatures, and monitoring structure changes of the samples by electron microscopy. Investigations were performed in the temperature range between 1200 C and 1700 C at a stress between 2 MPa and 15 MPa. (orig.)

  3. Development of a computer model to predict aortic rupture due to impact loading.

    Science.gov (United States)

    Shah, C S; Yang, K H; Hardy, W; Wang, H K; King, A I

    2001-11-01

    Aortic injuries during blunt thoracic impacts can lead to life threatening hemorrhagic shock and potential exsanguination. Experimental approaches designed to study the mechanism of aortic rupture such as the testing of cadavers is not only expensive and time consuming, but has also been relatively unsuccessful. The objective of this study was to develop a computer model and to use it to predict modes of loading that are most likely to produce aortic ruptures. Previously, a 3D finite element model of the human thorax was developed and validated against data obtained from lateral pendulum tests. The model included a detailed description of the heart, lungs, rib cage, sternum, spine, diaphragm, major blood vessels and intercostal muscles. However, the aorta was modeled as a hollow tube using shell elements with no fluid within, and its material properties were assumed to be linear and isotropic. In this study fluid elements representing blood have been incorporated into the model in order to simulate pressure changes inside the aorta due to impact. The current model was globally validated against experimental data published in the literature for both frontal and lateral pendulum impact tests. Simulations of the validated model for thoracic impacts from a number of directions indicate that the ligamentum arteriosum, subclavian artery, parietal pleura and pressure changes within the aorta are factors that could influence aortic rupture. The model suggests that a right-sided impact to the chest is potentially more hazardous with respect to aortic rupture than any other impact direction simulated in this study. The aortic isthmus was the most likely site of aortic rupture regardless of impact direction. The reader is cautioned that this model could only be validated on a global scale. Validation of the kinematics and dynamics of the aorta at the local level could not be done due to a lack of experimental data. It is hoped that this model will be used to design

  4. Developments in reactor materials science methodology

    International Nuclear Information System (INIS)

    Tsykanov, V.A.; Ivanov, V.B.

    1987-01-01

    Problems related to organization of investigations into reactor materials science are considered. Currently the efficiency and reliability of nuclear power units are largely determined by the fact, how correctly and quickly conclusions concerning the parameters of designs and materials worked out for a long time in reactor cores, are made. To increase information value of materials science investigations it is necessary to create a uniform system, providing for solving methodical, technical and organizational problems. Peculiarities of the current state of reactor material science are analysed and recommendations on constructing an optimal scheme of investigations and data flow interconnection are given

  5. Definitive diagnosis of breast implant rupture using magnetic resonance imaging.

    Science.gov (United States)

    Ahn, C Y; Shaw, W W; Narayanan, K; Gorczyca, D P; Sinha, S; Debruhl, N D; Bassett, L W

    1993-09-01

    Breast implant rupture is an important complication of augmented and reconstructed breasts. Although several techniques such as mammography, xeromammography, ultrasound, thermography, and computed tomographic (CT) scanning have been proven to be useful to detect implant rupture, they have several disadvantages and lack specificity. In the current study, we have established magnetic resonance imaging (MRI) as a definitive, reliable, and reproducible technique to diagnose both intracapsular and extracapsular ruptures. The study was conducted in 100 symptomatic patients. Our imaging parameters were able to identify ruptures in implants with silicone shells. All the ruptures showed the presence of wavy lines, free-floating silicone shell within the gel ("free-floating loose-thread sign" or "linguine sign"). We had a 3.75 percent incidence of false-positive and false-negative results. The sensitivity for detection of silicone implant rupture was 76 percent, with a specificity of 97 percent. In addition, we also were able to identify the artifacts that may interfere with the definitive diagnosis of implant rupture.

  6. Shigella subverts the host recycling compartment to rupture its vacuole.

    Science.gov (United States)

    Mellouk, Nora; Weiner, Allon; Aulner, Nathalie; Schmitt, Christine; Elbaum, Michael; Shorte, Spencer L; Danckaert, Anne; Enninga, Jost

    2014-10-08

    Shigella enters epithlial cells via internalization into a vacuole. Subsequent vacuolar membrane rupture allows bacterial escape into the cytosol for replication and cell-to-cell spread. Bacterial effectors such as IpgD, a PI(4,5)P2 phosphatase that generates PI(5)P and alters host actin, facilitate this internalization. Here, we identify host proteins involved in Shigella uptake and vacuolar membrane rupture by high-content siRNA screening and subsequently focus on Rab11, a constituent of the recycling compartment. Rab11-positive vesicles are recruited to the invasion site before vacuolar rupture, and Rab11 knockdown dramatically decreases vacuolar membrane rupture. Additionally, Rab11 recruitment is absent and vacuolar rupture is delayed in the ipgD mutant that does not dephosphorylate PI(4,5)P₂ into PI(5)P. Ultrastructural analyses of Rab11-positive vesicles further reveal that ipgD mutant-containing vacuoles become confined in actin structures that likely contribute to delayed vacular rupture. These findings provide insight into the underlying molecular mechanism of vacuole progression and rupture during Shigella invasion. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Morphological characteristics associated with rupture risk of multiple intracranial aneurysms.

    Science.gov (United States)

    Wang, Guang-Xian; Liu, Lan-Lan; Wen, Li; Cao, Yun-Xing; Pei, Yu-Chun; Zhang, Dong

    2017-10-01

    To identify the morphological parameters that are related to intracranial aneurysms (IAs) rupture using a case-control model. A total of 107 patients with multiple IAs and aneurysmal subarachnoid hemorrhage between August 2011 and February 2017 were enrolled in this study. Characteristics of IAs location, shape, neck width, perpendicular height, depth, maximum size, flow angle, parent vessel diameter (PVD), aspect ratio (AR) and size ratio (SR) were evaluated using CT angiography. Multiple logistic regression analysis was used to identify the independent risk factors associated with IAs rupture. Receiver operating characteristic curve analysis was performed on the final model, and the optimal thresholds were obtained. IAs located in the internal carotid artery (ICA) was associated with a negative risk of rupture, whereas AR, SR1 (height/PVD) and SR2 (depth/PVD) were associated with increased risk of rupture. When SR was calculated differently, the odds ratio values of these factors were also different. The receiver operating characteristic curve showed that AR, SR1 and SR2 had cut-off values of 1.01, 1.48 and 1.40, respectively. SR3 (maximum size/PVD) was not associated with IAs rupture. IAs located in the ICA are associated with a negative risk of rupture, while high AR (>1.01), SR1 (>1.48) or SR2 (>1.40) are risk factors for multiple IAs rupture. Copyright © 2017 Hainan Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  8. Creep Rupture Properties for Base and Weld Metals of Alloy 617

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Kim, Min-Hwan; Park, Jae-Young; Ekaputra, I. M. W.

    2015-01-01

    The allowable deformation in the welds is also restricted to half the deformation permitted for the base metal, since the ductility of the welds at elevated temperatures is generally low. For a design use, the data of the tensile and creep properties for Alloy 617 WM should be sufficiently provided, and in particular, to develop a design code of Alloy 617 WM. However, the data for the WM are very rare and limited until now, although the data for the BM are available in the ASME draft code case, which was suspended at the end of the 1980s owing to a lack of support and interes. In this report, the creep data for Alloy 617 WM, which was fabricated by a gas tungsten arc welding (GTAW) procedure, were obtained by a series of creep tests at 800 .deg. C, and the creep properties of the WM were compared with those of the BM. The high-temperature creep properties for Alloy 617 WM, fabricated by a gas tungsten arc welding (GTAW) procedure, were investigated by a series of creep tests with different stress levels at 800 .deg. C, and the creep test data for the WM were compared with those of the BM. From the results, it was found that the WM had a slightly longer creep rupture life and lower creep rate than the BM, and a particularly lower rupture elongation. The lower creep rate in the WM was due to the lower rupture elongation than the BM

  9. RELAP5 model to simulate the thermal-hydraulic effects of grid spacers and cladding rupture during reflood

    Energy Technology Data Exchange (ETDEWEB)

    Nithianandan, C.K.; Klingenfus, J.A.; Reilly, S.S. [B& W Nuclear Technologies, Lynchburg, VA (United States)

    1995-09-01

    Droplet breakup at spacer grids and a cladding swelled and ruptured locations plays an important role in the cooling of nuclear fuel rods during the reflooding period of a loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). During the reflood phase, a spacer grid affects the thermal-hydraulic system behavior through increased turbulence, droplet breakup due to impact on grid straps, grid rewetting, and liquid holdup due to grid form losses. Recently, models to simulate spacer grid effects and blockage and rupture effects on system thermal hydraulics were added to the B&W Nuclear Technologies (BWNT) version of the RELAP5/MOD2 computer code. Several FLECHT-SEASET forced reflood tests, CCTF Tests C1-19 and C2-6, SCTF Test S3-15, and G2 Test 561 were simulated using RELAP5/MOD2-B&W to verify the applicability of the model at the cladding swelled and rupture locations. The results demonstrate the importance of modeling the thermal-hydraulic effects due to grids, and clad swelling and rupture to correctly predict the clad temperature response during the reflood phase of large break LOCA. The RELAP5 models and the test results are described in this paper.

  10. Laparoscopic splenectomy for spontaneous rupture of the spleen

    Directory of Open Access Journals (Sweden)

    Pinky M Thapar

    2016-01-01

    Full Text Available Laparoscopic splenectomy is a gold standard for management of planned benign splenic pathologies. Spontaneous rupture of the spleen (SRS leading to acute abdomen occurs in only 1% of all splenic ruptures. Laparoscopic splenectomy in traumatic and atraumatic rupture due to intra-splenic pathology is reported. We present the first reported case of laparoscopic splenectomy in a 23-year-old male who presented with hemoperitoneum due to idiopathic or SRS. The procedure was safely accomplished with slight modified technique and minimum usage of advanced gadgets.

  11. CT diagnosis of traumatic bronchial rupture in children

    International Nuclear Information System (INIS)

    Epelman, Monica; Ofer, Amos; Guralnik, Ludmila; Klein, Yoram; Best, Leal H.; Bentur, Lea; Traubici, Jeffrey

    2002-01-01

    Bronchial rupture is a rare and serious complication of blunt chest trauma in children. The diagnosis of this injury is challenging and requires a high degree of clinical suspicion. It is frequently associated with other severe injuries that may draw the focus of attention away from this potentially catastrophic but treatable injury. The radiographic findings of bronchial rupture have been reported in very few series. We report the findings in two children with bronchial rupture diagnosed by CT, in whom CT resulted in a significant change in patient management. (orig.)

  12. Crystal plastic earthquakes in dolostones: from slow to fast ruptures.

    Science.gov (United States)

    Passelegue, F. X.; Aubry, J.; Nicolas, A.; Fondriest, M.; Schubnel, A.; Di Toro, G.

    2017-12-01

    Dolostone is the most dominant lithology of the seismogenic upper crust around the Mediterranean Sea. Understanding the internal mechanisms controlling fault friction is crucial for understanding seismicity along active faults. Displacement in such fault zones is frequently highlighted by highly reflective (mirror-like) slip surfaces, created by thin films of nanogranular fault rock. Using saw-cut dolostone samples coming from natural fault zones, we conducted stick-slip experiments under triaxial loading conditions at 30, 60 and 90 MPa confining pressure and temperature ranging from 30 to 100 degrees C. At 30 and 65 degrees C, only slow rupture was observed and the experimental fault exhibits frictional behaviour, i.e. a dependence of normal stress on peak shear stress. At 65 degrees C, a strengthening behaviour is observed after the main rupture, leading to a succession of slow rupture. At 100 degrees C, the macroscopic behaviour of the fault becomes ductile, and no dependence of pressure on the peak shear stress is observed. In addition, the increase of the confining pressure up to 60 and 90 MPa allow the transition from slow to fast rupture, highlighted by the records of acoustic activity and by dynamic stress drop occurring in a few tens of microseconds. Using strain gages located along the fault surface and acoustic transducers, we were able to measure the rupture velocities during slow and fast rupture. Slow ruptures propagated around 0.1 m/s, in agreement with natural observations. Fast ruptures propagated up to supershear velocities, i.e. faster than the shear wave speed (>3500 m/s). A complete study of the microstructures was realized before and after ruptures. Slow ruptures lead to the production of mirror-like surface driven by the production of nanograins due to dislocation processes. Fast ruptures induce the production of amorphous material along the fault surface, which may come from decarbonation and melting processes. We demonstrate that the

  13. Rupture of a Solid Pseudopapillary Neoplasm of the pancreas

    Directory of Open Access Journals (Sweden)

    Barbara Rampersad

    2018-03-01

    Full Text Available An acute presentation of a spontaneously ruptured Solid-Pseudopapillary Neoplasm (SPN in an 8 year old female is discussed with a review of the world literature. Our literature search revealed 15 other cases of ruptured SPN and with this case the total is now 16. Notably, 12 patients were 16 years of age or less at presentation as in our case. Although rupture of a SPN is rarely reported it appears to be more probable in the pediatric patient. Additionally, larger tumor size and trauma may be contributing factors.

  14. Creep rupture behavior of welded Grade 91 steel

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Triratna [Department of Chemical and Materials Engineering, University of Idaho, Moscow, ID 83844 (United States); Basirat, Mehdi [Department of Mechanical Engineering, University of Idaho, Moscow, ID 83844 (United States); Alsagabi, Sultan; Sittiho, Anumat [Department of Chemical and Materials Engineering, University of Idaho, Moscow, ID 83844 (United States); Charit, Indrajit, E-mail: icharit@uidaho.edu [Department of Chemical and Materials Engineering, University of Idaho, Moscow, ID 83844 (United States); Potirniche, Gabriel P. [Department of Mechanical Engineering, University of Idaho, Moscow, ID 83844 (United States)

    2016-07-04

    Creep rupture behavior of fusion welded Grade 91 steel was studied in the temperature range of 600 – 700 °C and at stresses of 50–200 MPa. The creep data were analyzed in terms of the Monkman-Grant relation and Larson-Miller parameter. The creep damage tolerance factor was used to identify the origin of creep damage. The creep damage was identified as the void growth in combination with microstructural degradation. The fracture surface morphology of the ruptured specimens was studied by scanning electron microscopy and deformed microstructure examined by transmission electron microscopy, to further elucidate the rupture mechanisms.

  15. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    Directory of Open Access Journals (Sweden)

    Erika Wernheden, MD

    2017-12-01

    Full Text Available Splenic artery aneurysms (SAAs are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA.

  16. Principal modes of rupture encountered in expertise of advanced components

    International Nuclear Information System (INIS)

    Tavassoli, A.A.; Bougault, A.

    1986-10-01

    Failure of many metallic components investigated can be classified into two categories: intergranular or transgranular according to their principal mode of rupture. Intergranular ruptures are often provoked by segregation of impurities at the grain boundaries. Three examples are cited where this phenomenon occured, one of them is a steel (A 508 cl 3) used for PWR vessel. Intergranular failures are in general induced by fatigue in the advanced components operating under thermal or load transients. One example concerning a sodium mixer which was subjected to thermal loadings is presented. Examples of stress corrosion and intergranular sensitization failures are cited. These examples show the importance of fractography for the determination of rupture causes [fr

  17. Radiological features of 80 cases of diaphragmatic rupture

    International Nuclear Information System (INIS)

    Sullivan, M.; Lee, R.

    1989-01-01

    The films from 80 cases of diaphragmatic rupture in the dog and cat over a 10 year period were examined. The most common findings were loss of the cupola and masking of the cardiac shadow. Identification of the stomach or intestine in the thorax made the diagnosis straightforward. However, in some animals these organs were not visible and there was considerable accumulation of free pleural fluid. The use of barium contrast studies and post drainage films were unable to confirm the presence of a rupture in all cases with inconclusive plain film findings. The identification of a rupture was only made by exploratory surgery in these animals

  18. Rupture directivity and slip distribution of the M 4.3 foreshock to the 1992 Joshua Tree earthquake, Southern California

    Science.gov (United States)

    Mori, J.

    1996-01-01

    Details of the M 4.3 foreshock to the Joshua Tree earthquake were studied using P waves recorded on the Southern California Seismic Network and the Anza network. Deconvolution, using an M 2.4 event as an empirical Green's function, corrected for complicated path and site effects in the seismograms and produced simple far-field displacement pulses that were inverted for a slip distribution. Both possible fault planes, north-south and east-west, for the focal mechanism were tested by a least-squares inversion procedure with a range of rupture velocities. The results showed that the foreshock ruptured the north-south plane, similar to the mainshock. The foreshock initiated a few hundred meters south of the mainshock and ruptured to the north, toward the mainshock hypocenter. The mainshock (M 6.1) initiated near the northern edge of the foreshock rupture 2 hr later. The foreshock had a high stress drop (320 to 800 bars) and broke a small portion of the fault adjacent to the mainshock but was not able to immediately initiate the mainshock rupture.

  19. Investigation of creep rupture properties in air and He environments of alloy 617 at 800 °C

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo-Gon, E-mail: wgkim@kaeri.re.k [Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Ekaputra, I.M.W.; Park, Jae-Young [Pukyong National University, Busan 608-739 (Korea, Republic of); Kim, Min-Hwan; Kim, Yong-Wan [Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

    2016-09-15

    Creep rupture properties for Alloy 617 were investigated by a series of creep tests under different applied stresses in air and He environments at 800 °C. The creep rupture time in air and He environments exhibited almost similar life in a short rupture time. However, when the creep rupture time reaches above 3000 h, the creep life in the He environment reduced compared with those of the air environment. The creep strain rate in the He environment was a little faster than that in the air environment above 3000 h. The reduction of creep life in the He environment was due to the difference of various microstructure features such as the carbide depleted zone, oxidation structures, surface cracking, voids below the surface, and voids in the matrix in air and He environments. Alloy 617 followed Norton’s power law and the Monkman–Grant relationship well. As the stress decreased, the creep ductility decreased slightly. The thickness of the outer and internal oxide layers presented the trend of a parabolic increase with an increase in creep rupture time in both the air and He environments. The thickness in the He environment was found to be thicker than in the air environment, although pure helium gas of 99.999% was used in the present investigation. The differences in the oxide-layer thickness caused detrimental effects on the creep resistance, even in a low oxygen-containing He agent.

  20. Investigation of creep rupture properties in air and He environments of alloy 617 at 800 °C

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Ekaputra, I.M.W.; Park, Jae-Young; Kim, Min-Hwan; Kim, Yong-Wan

    2016-01-01

    Creep rupture properties for Alloy 617 were investigated by a series of creep tests under different applied stresses in air and He environments at 800 °C. The creep rupture time in air and He environments exhibited almost similar life in a short rupture time. However, when the creep rupture time reaches above 3000 h, the creep life in the He environment reduced compared with those of the air environment. The creep strain rate in the He environment was a little faster than that in the air environment above 3000 h. The reduction of creep life in the He environment was due to the difference of various microstructure features such as the carbide depleted zone, oxidation structures, surface cracking, voids below the surface, and voids in the matrix in air and He environments. Alloy 617 followed Norton’s power law and the Monkman–Grant relationship well. As the stress decreased, the creep ductility decreased slightly. The thickness of the outer and internal oxide layers presented the trend of a parabolic increase with an increase in creep rupture time in both the air and He environments. The thickness in the He environment was found to be thicker than in the air environment, although pure helium gas of 99.999% was used in the present investigation. The differences in the oxide-layer thickness caused detrimental effects on the creep resistance, even in a low oxygen-containing He agent.

  1. Design prediction for long term stress rupture service of composite pressure vessels

    Science.gov (United States)

    Robinson, Ernest Y.

    1992-01-01

    Extensive stress rupture studies on glass composites and Kevlar composites were conducted by the Lawrence Radiation Laboratory beginning in the late 1960's and extending to about 8 years in some cases. Some of the data from these studies published over the years were incomplete or were tainted by spurious failures, such as grip slippage. Updated data sets were defined for both fiberglass and Kevlar composite stand test specimens. These updated data are analyzed in this report by a convenient form of the bivariate Weibull distribution, to establish a consistent set of design prediction charts that may be used as a conservative basis for predicting the stress rupture life of composite pressure vessels. The updated glass composite data exhibit an invariant Weibull modulus with lifetime. The data are analyzed in terms of homologous service load (referenced to the observed median strength). The equations relating life, homologous load, and probability are given, and corresponding design prediction charts are presented. A similar approach is taken for Kevlar composites, where the updated stand data do show a turndown tendency at long life accompanied by a corresponding change (increase) of the Weibull modulus. The turndown characteristic is not present in stress rupture test data of Kevlar pressure vessels. A modification of the stress rupture equations is presented to incorporate a latent, but limited, strength drop, and design prediction charts are presented that incorporate such behavior. The methods presented utilize Cartesian plots of the probability distributions (which are a more natural display for the design engineer), based on median normalized data that are independent of statistical parameters and are readily defined for any set of test data.

  2. Amnioinfusion for preterm premature rupture of membranes.

    Science.gov (United States)

    Hofmeyr, G Justus; Essilfie-Appiah, George; Lawrie, Theresa A

    2011-12-07

    Preterm premature rupture of membranes (PPROM) is a leading cause of perinatal morbidity and mortality. Amnioinfusion aims to restore amniotic fluid volume by infusing a solution into the uterine cavity. The objective of this review was to assess the effects of amnioinfusion for PPROM on perinatal and maternal morbidity and mortality. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2011). Randomised trials of amnioinfusion compared to no amnioinfusion in women with PPROM. Three review authors independently assessed trials for inclusion. Two review authors independently assessed trial quality and extracted data. Data were checked for accuracy. We included five trials but we only analysed data from four studies (with a total of 241 participants). One trial did not contribute any data to the review.Transcervical amnioinfusion improved fetal umbilical artery pH at delivery (mean difference 0.11; 95% confidence interval (CI) 0.08 to 0.14; one trial, 61 participants) and reduced persistent variable decelerations during labour (risk ratio (RR) 0.52; 95% CI 0.30 to 0.91; one trial, 86 participants).Transabdominal amnioinfusion was associated with a reduction in neonatal death (RR 0.30; 95% CI 0.14 to 0.66; two trials, 94 participants), neonatal sepsis (RR 0.26, 95% CI 0.11 to 0.61; one trial, 60 participants), pulmonary hypoplasia (RR 0.22; 95% CI 0.06 to 0.88; one trial, 34 participants) and puerperal sepsis (RR 0.20; 95% CI 0.05 to 0.84; one trial, 60 participants). Women in the amnioinfusion group were also less likely to deliver within seven days of membrane rupture (RR 0.18; 95% CI 0.05 to 0.70; one trial, 34 participants). These results should be treated with circumspection as the positive findings were mainly due to one trial with unclear allocation concealment. These results are encouraging but are limited by the sparse data and unclear methodological robustness, therefore further evidence is required before amnioinfusion for

  3. Antibiotics for preterm rupture of membranes.

    Science.gov (United States)

    Kenyon, Sara; Boulvain, Michel; Neilson, James P

    2013-12-02

    Premature birth carries substantial neonatal morbidity and mortality. Subclinical infection is associated with preterm rupture of membranes (PROM). Prophylactic maternal antibiotic therapy might lessen infectious morbidity and delay labour, but could suppress labour without treating underlying infection. To evaluate the immediate and long-term effects of administering antibiotics to women with PROM before 37 weeks, on maternal infectious morbidity, neonatal morbidity and mortality, and longer-term childhood development. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2013). Randomised controlled trials comparing antibiotic administration with placebo that reported clinically relevant outcomes were included as were trials of different antibiotics. Trials in which no placebo was used were included for the outcome of perinatal death alone. We extracted data from each report without blinding of either the results or the treatments that women received. We sought unpublished data from a number of authors. We included 22 trials, involving 6872 women and babies.The use of antibiotics following PROM is associated with statistically significant reductions in chorioamnionitis (average risk ratio (RR) 0.66, 95% confidence interval (CI) 0.46 to 0.96, and a reduction in the numbers of babies born within 48 hours (average RR 0.71, 95% CI 0.58 to 0.87) and seven days of randomisation (average RR 0.79, 95% CI 0.71 to 0.89). The following markers of neonatal morbidity were reduced: neonatal infection (RR 0.67, 95% CI 0.52 to 0.85), use of surfactant (RR 0.83, 95% CI 0.72 to 0.96), oxygen therapy (RR 0.88, 95% CI 0.81 to 0.96), and abnormal cerebral ultrasound scan prior to discharge from hospital (RR 0.81, 95% CI 0.68 to 0.98). Co-amoxiclav was associated with an increased risk of neonatal necrotising enterocolitis (RR 4.72, 95% CI 1.57 to 14.23).One study evaluated the children's health at seven years of age (ORACLE Children Study) and found

  4. Creep and creep rupture properties of cladding tube (type 316) in high temperature sodium

    International Nuclear Information System (INIS)

    Atsumo, H.

    1977-01-01

    The thin walled small sized seamless AISI 316 steel tubes, which are designated to be domestically used as the fuel cladding tube for sodium cooled fast breeder reactors in Japan, are irradiated in the following sodium of high temperature in the range of 370 deg. C to 700 deg. C, and receive gradually increased internal pressure caused by the fission produced gas generating from the nuclear fuel burn-up inside the cladding tube. Consequently, the creep behavior of fuel cladding tubes under a high temperature sodium environment is an important problem which must be determined and clarified together with their characteristic features under irradiation and in air. In relation to the creep performance of fuel cladding tubes made of AISI 316 steel and other comparable austenitic stainless steels, hardly any studies are found that are made systematically to examine the effect of sodium with sodium purity as parameter or any comparative studies with in-air data at various different temperatures. The present research work was aimed to obtain certain basic design data relating to in-sodium creep performance of the domestic made fuel cladding tubes for fast breeder reactors, and also to gain further date as considered necessary under several sodium conditions. That is, together with establishment of the technology for tensile creep test and internal pressure creep rupture test in flowing sodium of high temperature, a series of tests and studies were performed on the trial made cladding tubes of AISI Type-316 steel. In the first place, two kinds of purity conditions of sodium, close to the actual reactor-operating condition, (oxygen concentration of 10 ppm and 5 ppm respectively) were established, and then uniaxial tensile creep test and rupture test under various temperatures were performed and the resulting data were compared and evaluated against the in-air data. Then, secondly, an internal pressure creep rupture test was conducted under a single purity sodium environment

  5. Effect of inclusion content on the creep rupture properties of type 17Cr-8Ni-2Mo weld metals

    International Nuclear Information System (INIS)

    Senior, B.A.

    1988-01-01

    It has been known for some time that austenitic weldments exhibit low and variable creep rupture properties, but many of the factors controlling these properties are not well understood. In this investigation, two welds (Type 316) with similar compositions and fabricated using the same welding parameters, but with different electrode coatings, have been examined after creep testing. The results indicate that the inclusion and silicon content of type 316 welds can strongly influence their creep rupture properties, a high inclusion density being associated with poor creep rupture properties, and a low silicon content with a higher creep rate. This has been explained with reference to the micromechanism of creep failure operating in these welds. (author)

  6. Second trimester hepatic rupture in a 35 year old nulliparous woman with HELLP syndrome: a case report.

    LENUS (Irish Health Repository)

    Kelly, J

    2009-01-01

    The HELLP syndrome (haemolysis, elevated liver blood tests and low platelets) is a serious complication in pregnancy characterized by haemolysis, elevated liver enzymes and low platelet count occurring in 0.5 to 0.9% of all pregnancies and in 10-20% of cases with severe preeclampsia. Hepatic capsular rupture is a rare yet dramatic complication of HELLP syndrome. The majority of cases occur in multiparous women over the age of 30. Classically it presents with acute onset right upper quadrant pain in the presence of constitutional symptoms such as vomiting and pyrexia. However, symptoms and signs are usually non specific. Spontaneous hepatic rupture can be preceded by signs of hypovolaemic shock; yet the diagnosis is infrequently made prior to emergent laparotomy. We present the case of a 35 year old nulliparous woman with a second trimester gestational hepatic rupture associated with HELLP syndrome. We briefly discuss the aetiology, diagnostic difficulties and treatment options associated with this rare presentation.

  7. Microstructural evolution in reactor pressure vessel steel under neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Katsumi; Fukuya, Koji [Institute of Nuclear Safety System Inc., Seika, Kyoto (Japan)

    2000-09-01

    Understanding microstructural changes in reactor pressure vessel steels is important in order to evaluate radiation-induced embrittlement, one of the major aging phenomena affecting the extension of plant life. In this study, actual surveillance test specimens and samples of rector vessel low-alloy steel (A533B steel) irradiated in a research reactor were examined using state-of-the-art techniques to clarify the neutron flux effect on the microstructural changes. These techniques included small angle neutron scattering and atom probes. Microstructural changes which are considered to be the main factors affecting embrittlement, including the production of copper-rich precipitates and the segregation of impurity elements, were confirmed by the results of the study. In addition, the mechanical properties were predicted based on the obtained quantitative data such as the diameters of precipitates. Consequently, the hardening due to irradiation was almost simulated. (author)

  8. The influence of sex and trauma impact on the rupture site of the ulnar collateral ligament of the thumb.

    Science.gov (United States)

    Boesmueller, Sandra; Huf, Wolfgang; Rettl, Gregor; Dahm, Falko; Meznik, Alexander; Muschitz, Gabriela; Kitzinger, Hugo; Bukaty, Adam; Fialka, Christian; Vierhapper, Martin

    2017-01-01

    Although sex- and gender-specific analyses have been gaining more attention during the last years they have rarely been performed in orthopaedic literature. The primary purpose of this study was to investigate whether for injuries of the UCL the specific location of the rupture is influenced by sex. A secondary study question addressed the sex-independent effect of trauma intensity on the rupture site of the UCL. This study is a retrospective analysis of all patients with either a proximal or distal bony avulsion or with a mid-substance tear or ligament avulsion of the UCL treated surgically between 1992 and 2015 at two level-I trauma centres. Trauma mechanisms leading to the UCL injury were classified into the following categories: (1) blunt trauma (i.e., strains), (2) low-velocity injuries (e.g., fall from standing height, assaults), and (3) high-velocity injuries (e.g., sports injuries, motor vehicle accidents). After reviewing the surgical records, patients were divided into three groups, depending upon the ligament rupture site: (1) mid-substance tears, (2) proximal ligament or bony avulsions and (3) distal ligament or bony avulsions. Dependencies between the specific rupture site and the explanatory variables (sex, age, and trauma intensity) were evaluated using χ2 test and logistic regression analysis. In total, 1582 patients (1094 males, 488 females) met the inclusion criteria. Mean age was 41 years (range: 9-90 years). Taking into account the effects of sex on trauma intensity (p<0.001) and of trauma intensity on rupture site (p<0.001), mid-substance tears occurred more frequently in women, whereas men were more prone to distal ligament or bony avulsions (p<0.001). In other words, sex and rupture site correlated due to the effects of sex on trauma intensity and of trauma intensity on rupture site, but taking into account those effects there still was a significant effect of sex on rupture site. The results of this study demonstrate that with regression

  9. Development of gamma-ray densitometer and measurement of void fraction in instantaneous pipe rupture under BWR LOCA condition

    International Nuclear Information System (INIS)

    Yano, Toshikazu

    1983-11-01

    In order to clarify the transient mass flow rate under the instantaneous pipe rupture condition, it is necessary to use a highly sensitive void meter. Therefore, a high-response gamma-ray densitometer was developed for the measurement of void fraction variation caused by flashing vaporization of the high-pressure and -temperature water under the instantaneous pipe rupture accident. The measurement of void fraction was performed in the pipe rupture test under the BWR LOCA condition with a 6-inch diameter pipe. Initial conditions of the water were 6.86 MPa in pressure and the saturation temperature. To prove the reliability and accuracy, a calibration test by falling acrylic void simulators and an air injection test into cold water filled in the pipe were also conducted. The following results are obtained in the pipe rupture test. (1) The cone slit method is very useful to increase the measuring accuracy. (2) It is clearly observed that the apparent increase of void fraction occurs after the rarefaction wave passes. (3) The first maximum of void fraction occurs with some delay time after break. The following minimum void fraction concurs with the maximum pressure in the pressure recovering phenomena and with the maximum blowdown thrust force. (author)

  10. A case of a ruptured dermoid cyst

    International Nuclear Information System (INIS)

    Munemoto, Shigeru; Ishiguro, Shuso; Kimura, Akira; Kogure, Yuzaburou; Wakamatsu, Kouichi; Shimizu, Hiroshi; Hayashi, Morimoto

    1988-01-01

    A case of a ruptured dermoid cyst presenting headaches and dizziness as the only symptoms is presented. A 60-year-old woman was admitted to our hospital after complaining of headaches for 5 years and of dizziness for 1 week. The results of physical and neurological examinations were normal. An X-ray of the skull revealed an intracranial calcification in the left frontal region. CT disclosed calcification and a large low-density area in the left parasellar region and the frontal lobe. The mass consisted of two different areas of density. There were multiple, isolated, low-density spots in the left Sylvian fissure and the interpeduncular cistern. No abnormal enhancement was seen by CECT. Angiograms showed an elevation of the A 1 portion of ACA and a lateral shift of MCA. A left fronto-temporal craniotomy was performed. Chronic or past leptomeningitis was suspected because of the arachnoid-membrane thickening. Multiple fatty globules were present in the left Sylvian fissure. A large, soft, fatty tumor was completely removed. The histologic diagnosis was a dermoid cyst. After this operation, the headaches and dizziness were reduced. It is unclear whether the headaches were caused by the compression of the tumor or by the meningeal irritation of the fatty debris. According to the findings on the arachnoid membrane, however, it seems likely that fatty debris detached from the tumor spilled out intermittently from the cyst into the subarachnoid space, resulting in meningeal irritation. (author)

  11. Stress analysis of a rupture disk

    International Nuclear Information System (INIS)

    Werne, R.W.

    1975-04-01

    The results of an elastic stress analysis of the rupture disk for an internal pressure of 45.5 MPa (6600 psi) indicate that the maximum von Mises stresses occur in the membrane and are on the order of 483 to 690 MPa (70,000 psi). This far exceeds the yield of the membrane material of 207 MPa (30,000 psi). These high stresses are expected since the membrane is designed to burst at that design pressure. The von Mises stresses in the rest of the body are less than 138 MPa (20,000 psi). An elastic-plastic analysis of the membrane alone subjected to the 45.5 MPa (6600 psi) pressure indicates that it becomes plastically unstable, i.e., it continues to deform under constant load. A second load case with a constant 6.9 MPa (1000 psi) pressure throughout the entire body (i.e., after release of pressure by burst of the membrane) was analyzed. The results indicate that the elastic von Mises stresses are less than 26.7 MPa (3880 psi) throughout the body. (U.S.)

  12. Single Event Gate Rupture in 130-nm CMOS Transistor Arrays Subjected to X-Ray Irradiation

    CERN Document Server

    Silvestri, M; Gerardin, Simone; Faccio, Federico; Paccagnella, Alessandro

    2010-01-01

    We present new experimental results on heavy ion-induced gate rupture on deep submicron CMOS transistor arrays. Through the use of dedicated test structures, composed by a large number of 130-nm MOSFETs connected in parallel, we show the response to heavy ion irradiation under high stress voltages of devices previously irradiated with X-rays. We found only a slight impact on gate rupture critical voltage at a LET of 32 MeV cm(2) mg(-1) for devices previously irradiated up to 3 Mrad(SiO2), and practically no change for 100 Mrad(SiO2) irradiation, dose of interest for the future super large hadron collider (SLHC).

  13. Brittle and ductile rupture of 16MND5 steel. Irradiation effect

    International Nuclear Information System (INIS)

    Al Mundheri, M.; Soulat, P.; Pineau, A.

    1986-06-01

    Toughness tests have been made on 16MND5 steel (A508Cl3 steel) - before and after irradiation at 290 0 C (3.10 19 n/cm 2 , E > 1 MeV). It is shown that toughness is lowered following the irradiation and that it is a decreasing function of the thickness of the test pieces. In parallel, tests on three geometries of entailed specimens, prepared in the non-irradiated material, have been made at different temperatures to apply the methodology of local approach of ductile-brittle rupture [fr

  14. Experimental study of single event burnout and single event gate rupture in power MOSFETs and IGBT

    International Nuclear Information System (INIS)

    Tang Benqi; Wang Yanping; Geng Bin

    2001-01-01

    An experimental study was carried out to determine the single event burnout and single event gate rupture sensitivities in power MOSFETs and IGBT which were exposed to heavy ions from 252 Cf source. The test method, test results, a description of observed burnout current waveforms and a discussion of a possible failure mechanism were presented. Current measurements have been performed with a specially designed circuit. The test results include the observed dependence upon applied drain or gate to source bias and versus with external capacitors and limited resistors

  15. Spontaneous forniceal rupture: Can it be treated conservatively?

    Directory of Open Access Journals (Sweden)

    Ahmed Gaber Al-mujalhem

    2017-01-01

    Conclusion: Spontaneous forniceal rupture is more likely to occur with smaller distal ureteric stones. Conservative management is a valid option in non-complicated cases. Intervention should be reserved to complicated cases or cases with sizable urinoma.

  16. Plantar fascia rupture in a professional soccer player.

    Science.gov (United States)

    Suzue, Naoto; Iwame, Toshiyuki; Kato, Kenji; Takao, Shoichiro; Tateishi, Tomohiko; Takeda, Yoshitsugu; Hamada, Daisuke; Goto, Tomohiro; Takata, Yoichiro; Matsuura, Tetsuya; Sairyo, Koichi

    2014-01-01

    We report the case of a 29-year-old male professional soccer player who presented with symptoms of plantar fasciitis. His symptoms occurred with no remarkable triggers and gradually worsened despite conservative treatments including taping, use of insoles, and physical therapy. Local corticosteroid injection was given twice as a further intervention, but his plantar fascia partially ruptured 49 days after the second injection. He was treated conservatively with platelet-rich plasma, and magnetic resonance imaging showed regenerative change of the ruptured fascia. Five months after the rupture, he returned to his original level of training. If professional athletes find it difficult to refrain from athletic activity, as in the present case, the risk of rupture due to corticosteroid injection should not be overlooked.

  17. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  18. Induced seismicity provides insight into why earthquake ruptures stop

    KAUST Repository

    Galis, Martin; Ampuero, Jean Paul; Mai, Paul Martin; Cappa, Fré dé ric

    2017-01-01

    the perturbed area and distinguishes self-arrested from runaway ruptures. We develop a theoretical scaling relation between the largest magnitude of self-arrested earthquakes and the injected volume and find it consistent with observed maximum magnitudes

  19. Multiple Tophaceous Gout of Hand with Extensor Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Haruki Tobimatsu

    2017-01-01

    Full Text Available A 45-year-old man presented with painless subcutaneous masses bilaterally on his hands and loss of motion or contracture of the fingers. Initially, drug therapy to reduce the serum uric acid was administered and was expected to reduce the tophi. However, during observation at the clinic, spontaneous rupture of an extensor tendon occurred, and surgical repair of the tendon and resection of the masses were performed. Surgical exploration of the right hand showed hypertrophic white-colored crystal deposits that both surrounded and invaded the extensor digitorum communis of the index finger, which was ruptured. Histopathologic examination of the specimen demonstrated findings consistent with gouty tophi. Tophaceous gout can induce a rupture of tendons during clinical observation, and surgical resection of the tophi might be needed to prevent ruptures.

  20. A rare knee extensor mechanism injury: Vastus intermedius tendon rupture

    Directory of Open Access Journals (Sweden)

    Engin Cetinkaya

    2015-01-01

    Conclusion: We report the first case of isolated rupture of the vastus intermedius tendon in the literature and we claim that disorder may be succesfully treated with conservative treatment and adequate physiotheraphy.

  1. Pancreatic rupture in four cats with high-rise syndrome.

    Science.gov (United States)

    Liehmann, Lea M; Dörner, Judith; Hittmair, Katharina M; Schwendenwein, Ilse; Reifinger, Martin; Dupré, Gilles

    2012-02-01

    Pancreatic trauma and rupture are rare after feline high-rise syndrome; however, should it happen, pancreatic enzymes will leak into the abdominal cavity and may cause pancreatic autodigestion and fatty tissue saponification. If not diagnosed and treated, it can ultimately lead to multiorgan failure and death. In this case series, 700 records of high-rise syndrome cats that presented between April 2001 and May 2006 were analysed, and four cats with pancreatic rupture were identified. Clinical signs, diagnosis using ultrasonography and lipase activity in blood and abdominal effusion, and treatment modalities are reported. Three cats underwent surgical abdominal exploration, one cat was euthanased. Rupture of the left pancreatic limb was confirmed in all cases. Two of the operated cats survived to date. High-rise syndrome can lead to abdominal trauma, including pancreatic rupture. A prompt diagnosis and surgical treatment should be considered.

  2. Multi-Canister overpack necessity of the rupture disk

    International Nuclear Information System (INIS)

    SMITH, K.E.

    1998-01-01

    The Multi-Canister Overpack (MCO) rupture disk precludes the MCO from pressurization above the design limit during transport from the K Basins to the Cold Vacuum Drying (CVD) Facility and prior to connection of the CVD process piping. Removal of the rupture disk from the MCO design would: (a) result in unacceptable dose consequences in the event a thermal runaway accident occurred; (b) increase residual risk; and (c) remove a degree of specificity from the dose calculations. The potential cost savings of removing the rupture disk from the MCO design is offset by the cost of design modifications, changes to hazard analyses and safety analyses, and changes to existing documentation. Retaining the rupture disk mitigates the consequences of MCO overpressurization, and considering the overall economic impacts to the SNF Project, is the most cost effective approach

  3. Rapid Estimates of Rupture Extent for Large Earthquakes Using Aftershocks

    Science.gov (United States)

    Polet, J.; Thio, H. K.; Kremer, M.

    2009-12-01

    The spatial distribution of aftershocks is closely linked to the rupture extent of the mainshock that preceded them and a rapid analysis of aftershock patterns therefore has potential for use in near real-time estimates of earthquake impact. The correlation between aftershocks and slip distribution has frequently been used to estimate the fault dimensions of large historic earthquakes for which no, or insufficient, waveform data is available. With the advent of earthquake inversions that use seismic waveforms and geodetic data to constrain the slip distribution, the study of aftershocks has recently been largely focused on enhancing our understanding of the underlying mechanisms in a broader earthquake mechanics/dynamics framework. However, in a near real-time earthquake monitoring environment, in which aftershocks of large earthquakes are routinely detected and located, these data may also be effective in determining a fast estimate of the mainshock rupture area, which would aid in the rapid assessment of the impact of the earthquake. We have analyzed a considerable number of large recent earthquakes and their aftershock sequences and have developed an effective algorithm that determines the rupture extent of a mainshock from its aftershock distribution, in a fully automatic manner. The algorithm automatically removes outliers by spatial binning, and subsequently determines the best fitting “strike” of the rupture and its length by projecting the aftershock epicenters onto a set of lines that cross the mainshock epicenter with incremental azimuths. For strike-slip or large dip-slip events, for which the surface projection of the rupture is recti-linear, the calculated strike correlates well with the strike of the fault and the corresponding length, determined from the distribution of aftershocks projected onto the line, agrees well with the rupture length. In the case of a smaller dip-slip rupture with an aspect ratio closer to 1, the procedure gives a measure

  4. Rupture Dynamics and Ground Motion from Earthquakes in Heterogeneous Media

    Science.gov (United States)

    Bydlon, S.; Dunham, E. M.; Kozdon, J. E.

    2012-12-01

    Heterogeneities in the material properties of Earth's crust scatter propagating seismic waves. The effects of scattered waves are reflected in the seismic coda and depend on the relative strength of the heterogeneities, spatial arrangement, and distance from source to receiver. In the vicinity of the fault, scattered waves influence the rupture process by introducing fluctuations in the stresses driving propagating ruptures. Further variability in the rupture process is introduced by naturally occurring geometric complexity of fault surfaces, and the stress changes that accompany slip on rough surfaces. We have begun a modeling effort to better understand the origin of complexity in the earthquake source process, and to quantify the relative importance of source complexity and scattering along the propagation path in causing incoherence of high frequency ground motion. To do this we extended our two-dimensional high order finite difference rupture dynamics code to accommodate material heterogeneities. We generate synthetic heterogeneous media using Von Karman correlation functions and their associated power spectral density functions. We then nucleate ruptures on either flat or rough faults, which obey strongly rate-weakening friction laws. Preliminary results for flat faults with uniform frictional properties and initial stresses indicate that off-fault material heterogeneity alone can lead to a complex rupture process. Our simulations reveal the excitation of high frequency bursts of waves, which radiate energy away from the propagating rupture. The average rupture velocity is thus reduced relative to its value in simulations employing homogeneous material properties. In the coming months, we aim to more fully explore parameter space by varying the correlation length, Hurst exponent, and amplitude of medium heterogeneities, as well as the statistical properties characterizing fault roughness.

  5. Ultrasound Diagnosis of Bilateral Quadriceps Tendon Rupture After Statin Use

    Directory of Open Access Journals (Sweden)

    Nesselroade, Ryan D

    2010-09-01

    Full Text Available Simultaneous bilateral quadriceps tendon rupture is a rare injury. We report the case of bilateral quadriceps tendon rupture sustained with minimal force while refereeing a football game. The injury was suspected to be associated with statin use as the patient had no other identifiable risk factors.The diagnosis was confirmed using bedside ultrasound. [West J Emerg Med. 2010; 11(4:306-309.

  6. Ultrasound, CT and MRI of ruptured and disseminated hydatid cysts

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, W.N. von (King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia). Department of Radiology)

    Three cases of echinococcus granulosus with rupture of hydatid cysts and widespread abdominal, pelvic of pleural dissemination are described. Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) allowed recognition of ruptured hydatid cysts. This assisted to come to an appropriate therapy and exclusion or confirmation of hydatid cysts elsewhere in the body. Ultrasound, CT and MRI are also important for follow-up, evaluation of therapeutic response and/or early diagnosis of recurrence. (author). 22 refs.; 3 figs.

  7. Ultrasound, CT and MRI of ruptured and disseminated hydatid cysts

    International Nuclear Information System (INIS)

    Sinner, W.N. von

    1990-01-01

    Three cases of echinococcus granulosus with rupture of hydatid cysts and widespread abdominal, pelvic of pleural dissemination are described. Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) allowed recognition of ruptured hydatid cysts. This assisted to come to an appropriate therapy and exclusion or confirmation of hydatid cysts elsewhere in the body. Ultrasound, CT and MRI are also important for follow-up, evaluation of therapeutic response and/or early diagnosis of recurrence. (author). 22 refs.; 3 figs

  8. Delayed ventricular septal rupture complicating acute inferior wall myocardial infarction

    OpenAIRE

    Cho, Jae Hyung; Sattiraju, Srinivasan; Mehta, Sanjay; Missov, Emil

    2013-01-01

    Background Ventricular septal rupture is a potentially fatal complication of acute myocardial infarction. Its incidence has declined with modern reperfusion therapy. In the era of percutaneous coronary interventions, it occurs a median of 18?24?hours after myocardial infarction and is most commonly associated with anterior myocardial infarction. We present a case of delayed ventricular septal rupture complicating acute inferior wall myocardial infarction. Case presentation A 53-year-old Cauca...

  9. Reliability assessment of creep rupture life for Gr. 91 steel

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Park, Jae-Young; Kim, Seon-Jin; Jang, Jinsung

    2013-01-01

    Highlights: • Statistical analysis of a number of creep rupture data based on Z parameter. • Determination of the constant C in LM parameter and long-term creep life prediction. • Generation of random variables for Z s and Z cr by Monte-Carlo simulation in a SCRI model. • Examples for design application were reasonably drawn from the viewpoints of reliability. - Abstract: This paper presents reliability assessment of the long-term creep life of Gr. 91 steel, which is a major structural material for high temperature structural components of Generation-IV reactor systems. A number of creep rupture data for Gr. 91 steel were collected through literature surveys, and the long-term creep life was predicted by Larson–Miller parameter. A “Z parameter” method was used to describe the magnitude of the deviation of the creep rupture data to a master curve. A “Service Condition-creep Rupture property Interference (SCRI) model” based on the Z parameter was used to simultaneously consider the scattering of the creep rupture data of materials and the fluctuations of service conditions in reliability assessment. A statistical analysis of the creep rupture data was conducted by the Z parameter. To carry out the SCRI model, a number of random variables for Z s describing service conditions and Z cr describing the dispersion of the creep rupture data were generated using a Monte-Carlo simulation technique. As examples for application, the creep rupture life under a certain service conditions of Gr. 91 steel was reasonably drawn from the viewpoints of reliability

  10. Bifurcation of rupture path by linear and cubic damping force

    Science.gov (United States)

    Dennis L. C., C.; Chew X., Y.; Lee Y., C.

    2014-06-01

    Bifurcation of rupture path is studied for the effect of linear and cubic damping. Momentum equation with Rayleigh factor was transformed into ordinary differential form. Bernoulli differential equation was obtained and solved by the separation of variables. Analytical or exact solutions yielded the bifurcation was visible at imaginary part when the wave was non dispersive. For the dispersive wave, bifurcation of rupture path was invisible.

  11. MICROBIOLOGICAL STUDY ON ENDOCERVIX IN PRETERM PREMATURE RUPTURE OF MEMBRANE

    OpenAIRE

    Elizebeth V. Issac; Sareena Gilvaz; Neetha B. George

    2017-01-01

    BACKGROUND Preterm premature rupture of membrane (PPROM) is defined as premature rupture of membrane before 37 completed weeks. It is associated with 40% preterm deliveries and results in significant perinatal mortality and morbidity. Present study is an attempt to find the association between infection and PPROM. MATERIALS AND METHODS 100 pregnant women between 29 weeks and 34 weeks of gestation who were admitted in our labour room during a period from November 2012 to Nove...

  12. The stress-rupture behavior of tubes made from austenitic stainless steels and Ni-based alloys subjected to internal pressure

    International Nuclear Information System (INIS)

    Schaefer, L.; Kempe, H.

    1983-12-01

    The report outlines the stress-rupture results obtained on tubes tested as possible fuel rod cladding tubes for fast breeder reactors cooled with sodium, steam or gas. For the rupture elongations of some specimens showing a pronounced burst, higher values than in earlier reports are now indicated because of better evaluation techniques. The choice and comparisons of materials are explained, the calculations of stresses and strains are described, and reference is made to the own studies carried out to date of the parameters influencing creep-rupture behaviour. Minor modifications of the composition of an alloy and of the mechanical-thermal treatment of materials, respectively, are seen to produce clearcut changes in the stress-rupture properties. (orig.) [de

  13. Dynamic Models of Earthquake Rupture along branch faults of the Eastern San Gorgonio Pass Region in CA using Complex Fault Structure

    Science.gov (United States)

    Douilly, R.; Oglesby, D. D.; Cooke, M. L.; Beyer, J. L.

    2017-12-01

    Compilation of geomorphic and paleoseismic data have illustrated that the right-lateral Coachella segment of the southern San Andreas Fault is past its average recurrence time period. On its western edge, this fault segment is split into two branches: the Mission Creek strand, and the Banning fault strand, of the San Andreas. Depending on how rupture propagates through this region, there is the possibility of a through-going rupture that could lead to the channeling of damaging seismic energy into the Los Angeles Basin. The fault structures and rupture scenarios on these two strands are potentially very different, so it is important to determine which strand is a more likely rupture path, and under which circumstances rupture will take either one. In this study, we focus on the effect of different assumptions about fault geometry and stress pattern on the rupture process to test those scenarios and thus investigate the most likely path of a rupture that starts on the Coachella segment. We consider two types of fault geometry based on the SCEC Community Fault Model and create a 3D finite element mesh. These two meshes are then incorporated into the finite element method code FaultMod to compute a physical model for the rupture dynamics. We use the slip-weakening friction law, and we consider different assumptions of background stress such as constant tractions, regional stress regimes of different orientations, heterogeneous off-fault stresses and the results of long-term stressing rates from quasi-static crustal deformation models that consider time since last event on each fault segment. Both the constant and regional stress distribution show that it is more likely for the rupture to branch from the Coachella segment to the Mission Creek compared to the Banning fault segment. For the regional stress distribution, we encounter cases of super-shear rupture for one type of fault geometry and sub-shear rupture for the other one. The fault connectivity at this branch

  14. The effect of endograft device on patient outcomes in endovascular repair of ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir; Jetty, Prasad

    2017-12-01

    Objective Endovascular aneurysm repair for ruptured abdominal aortic aneurysm is being increasingly applied as the intervention of choice. The purpose of this study was to determine whether survival and reintervention rates after ruptured abdominal aortic aneurysm vary between endograft devices. Methods This cohort study identified all ruptured abdominal aortic aneurysms performed at The Ottawa Hospital from January 1999 to May 2015. Data collected included patient demographics, stability index at presentation, adherence to device instructions for use, endoleaks, reinterventions, and mortality. Kruskal-Wallis test was used to compare outcomes between groups. Mortality outcomes were assessed using Kaplan-Meier survival analysis, and multivariate Cox regression modeling. Results One thousand sixty endovascular aneurysm repairs were performed using nine unique devices. Ninety-six ruptured abdominal aortic aneurysms were performed using three devices: Cook Zenith ( n = 46), Medtronic Endurant ( n = 33), and Medtronic Talent ( n = 17). The percent of patients presented in unstable or extremis condition was 30.2, which did not differ between devices. Overall 30-day mortality was 18.8%, and was not statistically different between devices ( p = 0.16), although Medtronic Talent had markedly higher mortality (35.3%) than Cook Zenith (15.2%) and Medtronic Endurant (15.2%). AUI configuration was associated with increased 30-day mortality (33.3% vs. 12.1%, p = 0.02). Long-term mortality and graft-related reintervention rates at 30 days and 5 years were similar between devices. Instructions for use adherence was similar across devices, but differed between the ruptured abdominal aortic aneurysm and elective endovascular aneurysm repair cohorts (47.7% vs. 79.0%, p 30 days post-endovascular aneurysm repair ( p = 0.01). Type 1 endoleak rates differed significantly across devices (Cook Zenith 0.0%, Medtronic Endurant 18.2%, Medtronic Talent 17.6%, p = 0

  15. Hemoperitoneum from corpus luteum rupture in patients with aplastic anemia.

    Science.gov (United States)

    Wang, Huaquan; Guo, Lifang; Shao, Zonghong

    2015-01-01

    Aplastic anemia is a rare hematopoietic stem-cell disorder that results in pancytopenia and hypocellular bone marrow. Women with aplastic anemia usually are at increased risk of corpus luteum rupture due to thrombocytopenia and infection. Here we report two cases had hemoperitoneum from corpus luteum rupture in patients with aplastic anemia in our center. Case 1 involved two episodes of hemoperitoneum resulting from rupture of the corpus luteum in a 23-year-old unmarried female with severe aplastic anemia. This patient was managed conservatively with platelet and packed red cell transfusion. Case 2 involved two episodes of hemoperitoneum resulting from rupture of the corpus luteum in a 33-year-old married patient with aplastic anemia. Emergency laparoscopy revealed massive hemoperitoneum. Bilateral salpingo-oophorectomy were performed successively with platelet and packed red cell transfusion. Hemoperitoneum resulting from a ruptured corpus luteum is a life-threatening condition in patients with aplastic anemia. Prompt and appropriate evaluation of corpus luteum rupture and emergent therapy are needed.

  16. Retrospective Review of Pectoralis Major Ruptures in Rodeo Steer Wrestlers

    Directory of Open Access Journals (Sweden)

    Breda H. F. Lau

    2013-01-01

    Full Text Available Background. Pectoralis major tendon ruptures have been reported in the literature as occupational injuries, accidental injuries, and sporting activities. Few cases have been reported with respect to rodeo activities. Purpose. To describe a series of PM tendon ruptures in professional steer wrestlers. Study Design. Case series, level of evidence, 4. Methods. A retrospective analysis of PM ruptures in a steer wrestling cohort was performed. Injury data between 1992 and 2008 were reviewed using medical records from the University of Calgary Sport Medicine Center. Results. Nine cases of pectoralis major ruptures in professional steer wrestlers were identified. Injuries occurred during the throwing phase of the steer or while breaking a fall. All athletes reported unexpected or abnormal behavior of the steer that contributed to the mechanism of injury. Seven cases were surgically repaired, while two cases opted for nonsurgical intervention. Eight cases reported successful return to competition following the injury. Conclusion. Steer wrestlers represent a unique cohort of PM rupture case studies. Steer wrestling is a demanding sport that involves throwing maneuvers that may predispose the muscle to rupture. All cases demonstrated good functional outcomes regardless of surgical or non-surgical treatment.

  17. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    International Nuclear Information System (INIS)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo

    1988-01-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise. (author)

  18. Steam generator tube rupture effects on a LOCA

    International Nuclear Information System (INIS)

    LaChance, J.L.

    1979-01-01

    A problem currently experienced in commercial operating pressurized water reactors (PWR) in the United States is the degradation of steam generator tubes. Safety questions have arisen concerning the effect of these degraded tubes rupturing during a postulated loss-of-coolant accident (LOCA). To determine the effect of a small number of tube ruptures on the behavior of a large PWR during a postulated LOCA, a series of computer simulations was performed. The primary concern of the study was to determine whether a small number (10 or less of steam generator tubes rupturing at the beginning surface temperatures. Additional reflood analyses were performed to determine the system behavior when from 10 to 60 tubes rupture at the beginning of core reflood. The FLOOD4 code was selected as being the most applicable code for use in this study after an extensive analysis of the capabilities of existing codes to perform simulations of a LOCA with concurrent steam generator tube ruptures. The results of the study indicate that the rupturing of 10 or less steam generator tubes in any of the steam generators during a 200% cold leg break will not result in a significant increase in the peak cladding temperature. However, because of the vaporization of the steam generator secondary water in the primary side of the steam generator, a significant increase in the core pressure occurs which retards the reflooding process

  19. Pancreatic Pseudocyst Ruptured due to Acute Intracystic Hemorrhage

    Directory of Open Access Journals (Sweden)

    Kunishige Okamura

    2017-12-01

    Full Text Available Rupture of pancreatic pseudocyst is one of the rare complications and usually results in high mortality. The present case was a rupture of pancreatic pseudocyst that could be treated by surgical intervention. A 74-year-old man developed abdominal pain, vomiting, and diarrhea, and he was diagnosed with cholecystitis and pneumonia. Three days later, acute pancreatitis occurred and computed tomography (CT showed slight hemorrhage in the cyst of the pancreatic tail. After another 10 days, CT showed pancreatic cyst ruptured due to intracystic hemorrhage. Endoscopic retrograde cholangiopancreatography revealed leakage of contrast agent from pancreatic tail cyst to enclosed abdominal cavity. His left hypochondrial pain was increasing, and CT showed rupture of the cyst of the pancreatic tail into the peritoneal cavity was increased in 10 days. CT showed also two left renal tumors. Therefore we performed distal pancreatectomy with concomitant resection of transverse colon and left kidney. We histopathologically diagnosed pancreatic pseudocyst ruptured due to intracystic hemorrhage and renal cell carcinoma. Despite postoperative paralytic ileus and fluid collection at pancreatic stump, they improved by conservative management and he could be discharged on postoperative day 29. He has achieved relapse-free survival for 6 months postoperatively. The mortality of pancreatic pseudocyst rupture is very high if some effective medical interventions cannot be performed. It should be necessary to plan appropriate treatment strategy depending on each patient.

  20. Location of Ruptured Bullae in Secondary Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Jinseok Choi

    2017-12-01

    Full Text Available Background: The surgical treatment of secondary spontaneous pneumothorax (SSP can be complicated by fragile lung parenchyma. The preoperative prediction of air leakage could help prevent intraoperative lung in-jury during manipulation of the lung. Common sites of bulla development and ruptured bullae were inves-tigated based on computed tomography (CT and intraoperative findings. Methods: The study enrolled 208 patients with SSP who underwent air leak control through video-assisted thoracoscopic surgery (VATS. We retrospectively reviewed the sites of bulla development on preoperative CT and the rupture sites during VATS. Results: Of the 135 cases of right-sided SSP, the most common rupture site was the apical segment (31.9%, followed by the azygoesophageal recess (27.4%. Of the 75 cases on the left side, the most com-mon rupture site was the apical segment (24.0%, followed by the anterior basal segment (17.3%. Conclusion: The azygoesophageal recess and parenchyma along the cardiac border were common sites of bul-la development and rupture. Studies of respiratory lung motion to measure the pleural pressure at the lung surface could help to determine the relationship between cardiogenic and diaphragmatic movement and bulla formation or rupture.

  1. Nontraumatic spontaneous rupture of the kidney : etiology and CT findings

    International Nuclear Information System (INIS)

    Heo, Tae Haeng; Jeon, Hae Jeong; Shin, Hyun Joon; Kim, Bo Hyun; Cho, Kyoung Sik; Kim, Young Hwa; Kim, Seung Hyup; Park, Churl Min

    1997-01-01

    To evaluate the usefulness of CT scanning in determining the etiology of spontaneous rupture of the kidney We retrospectively analyzed the CT findings of spontaneous rupture of the kidney in eleven patients, Four were male and seven were female, and they were aged between 20 and 71 (mean, 46.6) years. Both pre- and post-contrast enhanced CT scanning was performed in all patients. Spontaneous renal rupture was induced in seven cases by neoplasms (three angiomyolipomas, three renal cell carcinomas, and one metastatic choriocarcinoma), in three cases by infection or inflammation (acute and chronic pyelonephritis, and renal abscess), and in one, by renal cyst. Common CT findings of rupture of the kidney were the accumulation of high density fluid in the perirenal and anterior pararenal space, and inhomogeneous irregular low density of renal parenchyma and the rupture site. Angiomyolipoma showed fat and an angiomatous component in the lesion, while acute and chronic pyelonephrities revealed thinning of the renal parenchyma and an irregular renal outline. Renal cell carcinoma showed a dense soft tissue mass in the parenchyma. Well-defined, round low-density lesions were noted in the case of renal cyst and renal abscess. CT is very useful in diagnosing and determining the etiology of non-traumatic spontaneous rupture of the kidney and plays an important role in the evaluation of emergency cases

  2. Radiolytic generation of gases in reactors

    International Nuclear Information System (INIS)

    Ramshesh, V.; Venkateswarlu, K.S.

    1988-01-01

    Water or heavy water is used in different circuits in a reactor. Their most common use is as a moderator and/or as a coolant. Light water is used at other places such as in end shield, calandria vault etc., In the process they are exposed to intense ionizing radiation and undergo radiolytic degradation. The molecular produts of radiolysis are hydrogen, hydrogen peroxide and oxygen. As is commonly known if hydrogen is formed beyond a certain level, in the presence of oxygen it may lead to combustion or even explosion. Thus one should comprehend the basic principles of radiolysis and see whether the concentration of these gases under various conditions can be worked out. This report attempts to analyse in depth the radiolytic generation of gases in reactor systems. (author). 3 tabs

  3. Cooperation in reactor design evaluation and licensing

    International Nuclear Information System (INIS)

    Kaufer, B.; Wasylyk, A.

    2014-01-01

    In January 2007 the World Nuclear Association (WNA) established the Cooperation in Reactor Design Evaluation and Licensing (CORDEL) Working Group with the aim of stimulating a dialogue between the nuclear industry (including reactor vendors, operators and utilities) and nuclear regulators (national and international organisations) on the benefits and means of achieving a worldwide convergence of reactor safety standards for reactor designs. From the time of its inception to the present, CORDEL has evolved from a group of experts discussing how to achieve international standardisation in nuclear safety design to an established and recognised working group dedicated to analysing and forging common understandings in key areas as input to major decisions on nuclear energy policy. This paper will review the general directions and activities CORDEL plans to undertake during the next five-year period, including its general strategy, activities, priorities and interactions with its customers in order to meet its objectives. (author)

  4. Cooperation in reactor design evaluation and licensing

    Energy Technology Data Exchange (ETDEWEB)

    Kaufer, B.; Wasylyk, A. [World Nuclear Association, London (United Kingdom)

    2014-07-01

    In January 2007 the World Nuclear Association (WNA) established the Cooperation in Reactor Design Evaluation and Licensing (CORDEL) Working Group with the aim of stimulating a dialogue between the nuclear industry (including reactor vendors, operators and utilities) and nuclear regulators (national and international organisations) on the benefits and means of achieving a worldwide convergence of reactor safety standards for reactor designs. From the time of its inception to the present, CORDEL has evolved from a group of experts discussing how to achieve international standardisation in nuclear safety design to an established and recognised working group dedicated to analysing and forging common understandings in key areas as input to major decisions on nuclear energy policy. This paper will review the general directions and activities CORDEL plans to undertake during the next five-year period, including its general strategy, activities, priorities and interactions with its customers in order to meet its objectives. (author)

  5. No difference between mechanical perturbation training with compliant surface and manual perturbation training on knee functional performance after ACL rupture.

    Science.gov (United States)

    Nawasreh, Zakariya; Logerstedt, David; Failla, Mathew; Snyder-Mackler, Lynn

    2017-10-27

    Manual perturbation training improves dynamic knee stability and functional performance after anterior cruciate ligament rupture (ACL-rupture). However, it is limited to static standing position and does not allow time-specific perturbations at different phase of functional activities. The purpose of this study was to investigate whether administering mechanical perturbation training including compliant surface provides effects similar to manual perturbation training on knee functional measures after an acute ACL-rupture. Sixteen level I/II athletes with ACL-ruptures participated in this preliminary study. Eight patients received mechanical (Mechanical) and eight subjects received manual perturbation training (Manual). All patients completed a functional testing (isometric quadriceps strength, single-legged hop tests) and patient-reported measures (Knee Outcome Survey-Activities of Daily Living Scale (KOS-ADLS), Global Rating Score (GRS), International Knee Documentation Committee 2000 (IKDC 2000) at pre- and post-training. 2 × 2 ANOVA was used for data analysis. No significant group-by-time interactions were found for all measures (p > 0.18). Main effects of time were found for single hop (Pre-testing: 85.14% ± 21.07; Post-testing: 92.49% ± 17.55), triple hop (Pre-testing: 84.64% ± 14.17; Post-testing: 96.64% ± 11.14), KOS-ADLS (Pre-testing: 81.13% ± 11.12; Post-testing: 88.63% ± 12.63), GRS (Pre-testing: 68.63% ± 15.73; Post-testing: 78.81% ± 13.85), and IKDC 2000 (Pre-testing: 66.66% ± 9.85; Post-testing: 76.05% ± 14.62) (p training using compliant surfaces induce effects similar to manual perturbation training on knee functional performance after acute ACL-rupture. The clinical significance is both modes of training improve patients' functional-performance and limb-to-limb movement symmetry, and enhancing the patients' self-reported of knee functional measures after ACL rupture. Mechanical

  6. Effect of some thermomechanical variables on plastic flow and creep-rupture of type 304 stainless steel at 5930C

    International Nuclear Information System (INIS)

    Swindeman, R.W.

    1977-01-01

    As part of an effort to examine sources of variability in the creep-rupture behavior of type 304 stainless steel, specimens subjected to a variety of prior thermomechanical treatments were tested. Included were different reannealing temperatures, cooling rates, types of prior straining, and a 24-hr age at 816 0 C. Two product forms of a single heat (heat 9T2796) were involved, and most testing was at 593 0 C. For material with coarse grain size, reannealing temperature had no pronounced influence. However, slow cooling rates and the 816 0 C aging significantly extended the rupture life. On the other hand, cold working by an equivalent of 4% tensile strain had very little influence on rupture life. Slow cooling or aging increased rupture life as a result of greatly improved creep ductility. This finding is consistent with similar observations in the literature for this and other stainless steels, and is believed to be due to the development of coarse, beneficial carbides on grain boundaries before stressing. The creep response in the primary and secondary stages was influenced by nearly all the thermomechanical treatments, but the variability in the response at relatively high stresses was scarcely greater than the variability observed in multiple tests on specimens having a common thermomechanical history. 10 figures, 1 table

  7. Long-term functional outcome of bilateral spontaneous and simultaneous Achilles tendon ruptures.

    LENUS (Irish Health Repository)

    Ellanti, Prasad

    2012-10-01

    Bilateral simultaneous ruptures are rare comprising less than 1% of all Achilles tendon ruptures. Risk factors for bilateral ruptures include chronic diseases and medications such as corticosteroids and fluoroquinolones. There is little in the literature on the long-term functional outcome of bilateral Achilles tendon ruptures. This article present a series of 3 cases of simultaneous and spontaneous bilateral Achilles tendon ruptures with a minimum of 5-year follow up suggesting a good functional outcome.

  8. Use of grafts in rotator cuff re-rupture.

    Science.gov (United States)

    Jiménez-Martín, A; Santos-Yubero, F J; Najarro-Cid, F J; Navarro-Martínez, S; Zurera-Carmona, M; Pérez-Hidalgo, S

    2016-01-01

    Rotator cuff re-ruptures appear in 38-65% of cases. In order to reduce this rate, many studies have been performed using different types of biomaterial for purely mechanical aims (re-inforce the suture) and/or biological agents (growth factor transporterts). The aim of this study is to review 22 cases treated with xenografts and analyse various current alternatives. A descriptive and retrospective study was conducted using the variables of age, sex, laterality, time of surgery, involvement in MRI, number of anchors, and final mobility results on the Constant and the University of California Los Angeles (UCLA) validated scales. The study included 22 patients, with a mean age of 51.7±4.6 years. A mean of 2 anchors were used and 13 patients were treated with a porcine intestinal submucosa implant, 6 with equine pericardium, and 3 with porcine dermis. Final results were: 37.6±13 points for the Constant test, and 16.9±3.9 points on the UCLA scale. The follow up was 36±10.2 months. In our experience, xenografts could provide good functional results and they would be a surgical alternative to tendon transfers in cases of massive tears. Further studies should be conducted with other biomaterials. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Intraamniotic Inflammation in Women with Preterm Prelabor Rupture of Membranes.

    Directory of Open Access Journals (Sweden)

    Ivana Musilova

    Full Text Available To characterize subgroups of preterm prelabor rupture of membranes (PPROM and short-term neonatal outcomes based on the presence and absence of intraamniotic inflammation (IAI and/or microbial invasion of the amniotic cavity (MIAC.One hundred and sixty-six Caucasian women with singleton pregnancies were included in this study. Amniotic fluid samples were obtained by transabdominal amniocentesis (n=166 and were assayed for interleukin-6 levels by a lateral flow immunoassay. The presence of Ureaplasma species, Mycoplasma hominis, Chlamydia trachomatis, and 16S rRNA was evaluated in the amniotic fluid. IAI was defined as amniotic fluid IL-6 values, measured by a point of care test, higher than 745 pg/mL.Microbial-associated IAI (IAI with MIAC and sterile intraamniotic inflammation (IAI alone were found in 21% and 4%, respectively, of women with PPROM. Women with microbial-associated IAI had higher microbial loads of Ureaplasma species in the amniotic fluid than women with MIAC alone. No differences in the short-term neonatal morbidity with respect to the presence of microbial-associated IAI, sterile IAI and MIAC alone were found after adjusting for the gestational age at delivery in women with PPROM.Microbial-associated but not sterile intraamniotic inflammation is common in Caucasian women with PPROM. The gestational age at delivery but not the presence of inflammation affects the short-term neonatal morbidity of newborns from PPROM pregnancies.

  10. CATHENA simulations of steam generator tube rupture

    International Nuclear Information System (INIS)

    Abdul-Razzak, A.; Lin, M.R.; Wright, A.C.D.

    1997-01-01

    The CATHENA thermalhydraulic computer code was used to simulate various scenarios following a CANDU 9 steam generator tube rupture (SGTR) event. The analysis included cases with class IV power and emergency core cooling system (ECCS) available and other cases with subsequent loss of class IV power (LCIVP) or impairment of ECCS injection. Two main approaches were followed in the analysis of each case. In the first approach, D 2 O feed was credited to provide conservative data for input to radionuclide release and dose calculations. Also operator actions are credited. The other approach is designed to give conservative predictions with respect to the acceptance criteria of fuel and fuel channel integrity and to prove that in case of such event, the operator will have enough time to mitigate the consequences. This is done by not crediting makeup for the inventory loss and relying on the automatic operation of safety systems. The analysis of the cases of the first approach provided the required data for radionuclide release and dose calculations and gave a good insight into the required sequence of operator timely actions to mitigate the consequences of such event. On the other hand, the cases of the second approach confirmed compliance with regulatory requirements for pressure tube and fuel integrity. The runs with ECCS available, showed the ECCS injection is effective in filling and cooling the core and that regulatory requirement's for fuel and channel integrity are met. In the event of ECCS impairment, the earliest indication of late fuel heat-up is late enough to provide the operator with an adequate time to act in mitigating the consequences of this event. (author)

  11. Comparison between smaller ruptured intracranial aneurysm and larger un-ruptured intracranial aneurysm: gene expression profile analysis.

    Science.gov (United States)

    Li, Hao; Li, Haowen; Yue, Haiyan; Wang, Wen; Yu, Lanbing; ShuoWang; Cao, Yong; Zhao, Jizong

    2017-07-01

    As it grows in size, an intracranial aneurysm (IA) is prone to rupture. In this study, we compared two extreme groups of IAs, ruptured IAs (RIAs) smaller than 10 mm and un-ruptured IAs (UIAs) larger than 10 mm, to investigate the genes involved in the facilitation and prevention of IA rupture. The aneurismal walls of 6 smaller saccular RIAs (size smaller than 10 mm), 6 larger saccular UIAs (size larger than 10 mm) and 12 paired control arteries were obtained during surgery. The transcription profiles of these samples were studied by microarray analysis. RT-qPCR was used to confirm the expression of the genes of interest. In addition, functional group analysis of the differentially expressed genes was performed. Between smaller RIAs and larger UIAs, 101 genes and 179 genes were significantly over-expressed, respectively. In addition, functional group analysis demonstrated that the up-regulated genes in smaller RIAs mainly participated in the cellular response to metal ions and inorganic substances, while most of the up-regulated genes in larger UIAs were involved in inflammation and extracellular matrix (ECM) organization. Moreover, compared with control arteries, inflammation was up-regulated and muscle-related biological processes were down-regulated in both smaller RIAs and larger UIAs. The genes involved in the cellular response to metal ions and inorganic substances may facilitate the rupture of IAs. In addition, the healing process, involving inflammation and ECM organization, may protect IAs from rupture.

  12. Simulating Earthquake Rupture and Off-Fault Fracture Response: Application to the Safety Assessment of the Swedish Nuclear Waste Repository

    KAUST Repository

    Falth, B.

    2014-12-09

    To assess the long-term safety of a deep repository of spent nuclear fuel, upper bound estimates of seismically induced secondary fracture shear displacements are needed. For this purpose, we analyze a model including an earthquake fault, which is surrounded by a number of smaller discontinuities representing fractures on which secondary displacements may be induced. Initial stresses are applied and a rupture is initiated at a predefined hypocenter and propagated at a specified rupture speed. During rupture we monitor shear displacements taking place on the nearby fracture planes in response to static as well as dynamic effects. As a numerical tool, we use the 3Dimensional Distinct Element Code (3DEC) because it has the capability to handle numerous discontinuities with different orientations and at different locations simultaneously. In tests performed to benchmark the capability of our method to generate and propagate seismic waves, 3DEC generates results in good agreement with results from both Stokes solution and the Compsyn code package. In a preliminary application of our method to the nuclear waste repository site at Forsmark, southern Sweden, we assume end-glacial stress conditions and rupture on a shallow, gently dipping, highly prestressed fault with low residual strength. The rupture generates nearly complete stress drop and an M-w 5.6 event on the 12 km(2) rupture area. Of the 1584 secondary fractures (150 m radius), with a wide range of orientations and locations relative to the fault, a majority move less than 5 mm. The maximum shear displacement is some tens of millimeters at 200 m fault-fracture distance.

  13. Creep Rupture Life Prediction Based on Analysis of Large Creep Deformation

    Directory of Open Access Journals (Sweden)

    YE Wenming

    2016-08-01

    Full Text Available A creep rupture life prediction method for high temperature component was proposed. The method was based on a true stress-strain elastoplastic creep constitutive model and the large deformation finite element analysis method. This method firstly used the high-temperature tensile stress-strain curve expressed by true stress and strain and the creep curve to build materials' elastoplastic and creep constitutive model respectively, then used the large deformation finite element method to calculate the deformation response of high temperature component under a given load curve, finally the creep rupture life was determined according to the change trend of the responsive curve.The method was verified by durable test of TC11 titanium alloy notched specimens under 500 ℃, and was compared with the three creep rupture life prediction methods based on the small deformation analysis. Results show that the proposed method can accurately predict the high temperature creep response and long-term life of TC11 notched specimens, and the accuracy is better than that of the methods based on the average effective stress of notch ligament, the bone point stress and the fracture strain of the key point, which are all based on small deformation finite element analysis.

  14. Ruptured Splenic Abscess following Percutaneous Transluminal Angioplasty in a 40-Year-Old Man

    Directory of Open Access Journals (Sweden)

    C. Rajasekharan

    2012-05-01

    Full Text Available The incidence of splenic abscesses is currently 0.14–0.7% with a reported mortality of 0–47%. The diagnosis of splenic abscess which has ruptured into the abdomen is often overlooked because of its rarity and its misleading clinical presentations. Percutaneous coronary interventions (PCIs and coronary stenting procedures increased from 184,000 to 885,000 (from 335 to 1,550 and from 3,000 to 770,000 (from 5 to 1,350 per one million inhabitants, respectively. A 40-year-old Asian male presented to our emergency department with upper abdominal pain 5 days after a percutaneous transluminal coronary angioplasty. Clinical examination raised the possibilities of acute pancreatitis and intraabdominal sepsis. An initial ultrasound of the abdomen and blood tests were negative. A computed tomography scan of the abdomen revealed a splenic abscess that had ruptured into the abdomen. Pus culture revealed a multidrug-resistant strain of Klebsiella pneumoniae that was sensitive to meropenem. The patient recovered quickly after open surgical drainage and antibiotic therapy. As this is the second case of splenic abscess and the first case report of a ruptured splenic abscess following a PCI, it will be rational to administer a short course of antibiotic prophylaxis for high-risk immunocompromised patients who are undergoing percutaneous transluminal coronary intervention.

  15. Uncertainty analysis for probabilistic steam generators tube rupture in LBB applications

    Energy Technology Data Exchange (ETDEWEB)

    Durbec, V.; Pitner, P.; Pages, D. [Electricite de France, 78 - Chatou (France). Research and Development Div.; Riffard, T. [Electricite de France, 69 - Villeurbanne (France). Engineering and Construction Div.; Flesch, B. [Electricite de France, 92 - Paris la Defense (France). Generation and Transmission Div.

    1997-10-01

    Steam Generators (SG) of Pressurized Water Reactors have experienced world wide various types of tube degradations, mainly from stress corrosion cracking; because of this damage, primary-secondary leakage or tube rupture can occur. Safety against the risk of tube rupture is achieved through a combination of periodic in-service inspections (eddy current testing), surveillance of leaks during operation (leak before break concept) and tube plugging. In order to optimize the tube bundle SG maintenance, Electricite de France has developed a specific software named COMPROMIS. The model, based on probabilistic fracture mechanics makes it possible to quantify the influence of in service inspections and maintenance work on the risk of a SG Tube Rupture (SGTR), taking all significant parameters into account as random variables (initial defect size distribution, reliability of non-destructive examinations, crack initiation and propagation, critical sizes, leak before risk of break, etc...). This paper focuses on the leak rate calculation module and presents a sensitivity study of the influence of the leak before break on the conditional failure probability. (author) 8 refs.

  16. Uncertainty analysis for probabilistic steam generators tube rupture in LBB applications

    International Nuclear Information System (INIS)

    Durbec, V.; Pitner, P.; Pages, D.; Riffard, T.; Flesch, B.

    1997-10-01

    Steam Generators (SG) of Pressurized Water Reactors have experienced world wide various types of tube degradations, mainly from stress corrosion cracking; because of this damage, primary-secondary leakage or tube rupture can occur. Safety against the risk of tube rupture is achieved through a combination of periodic in-service inspections (eddy current testing), surveillance of leaks during operation (leak before break concept) and tube plugging. In order to optimize the tube bundle SG maintenance, Electricite de France has developed a specific software named COMPROMIS. The model, based on probabilistic fracture mechanics makes it possible to quantify the influence of in service inspections and maintenance work on the risk of a SG Tube Rupture (SGTR), taking all significant parameters into account as random variables (initial defect size distribution, reliability of non-destructive examinations, crack initiation and propagation, critical sizes, leak before risk of break, etc...). This paper focuses on the leak rate calculation module and presents a sensitivity study of the influence of the leak before break on the conditional failure probability. (author)

  17. Reliability and validation of the Dutch Achilles tendon Total Rupture Score.

    Science.gov (United States)

    Opdam, K T M; Zwiers, R; Wiegerinck, J I; Kleipool, A E B; Haverlag, R; Goslings, J C; van Dijk, C N

    2018-03-01

    Patient-reported outcome measures (PROMs) have become a cornerstone for the evaluation of the effectiveness of treatment. The Achilles tendon Total Rupture Score (ATRS) is a PROM for outcome and assessment of an Achilles tendon rupture. The aim of this study was to translate the ATRS to Dutch and evaluate its reliability and validity in the Dutch population. A forward-backward translation procedure was performed according to the guidelines of cross-cultural adaptation process. The Dutch ATRS was evaluated for reliability and validity in patients treated for a total Achilles tendon rupture from 1 January 2012 to 31 December 2014 in one teaching hospital and one academic hospital. Reliability was assessed by the intraclass correlation coefficients (ICC), Cronbach's alpha and minimal detectable change (MDC). We assessed construct validity by calculation of Spearman's rho correlation coefficient with domains of the Foot and Ankle Outcome Score (FAOS), Victorian Institute of Sports Assessment-Achilles questionnaire (VISA-A) and Numeric Rating Scale (NRS) for pain in rest and during running. The Dutch ATRS had a good test-retest reliability (ICC = 0.852) and a high internal consistency (Cronbach's alpha = 0.96). MDC was 30.2 at individual level and 3.5 at group level. Construct validity was supported by 75 % of the hypothesized correlations. The Dutch ATRS had a strong correlation with NRS for pain during running (r = -0.746) and all the five subscales of the Dutch FAOS (r = 0.724-0.867). There was a moderate correlation with the VISA-A-NL (r = 0.691) and NRS for pain in rest (r = -0.580). The Dutch ATRS shows an adequate reliability and validity and can be used in the Dutch population for measuring the outcome of treatment of a total Achilles tendon rupture and for research purposes. Diagnostic study, Level I.

  18. Success of nonoperative management of adductor longus tendon ruptures in National Football League athletes.

    Science.gov (United States)

    Schlegel, Theodore F; Bushnell, Brandon D; Godfrey, Jenna; Boublik, Martin

    2009-07-01

    Acute complete ruptures of the proximal adductor longus tendon are rare but challenging injuries to treat. The limited literature supports operative treatment, but data from management of chronic groin pain in athletes indicate that anatomical attachment of the tendon to the pubis may not be required for high-level function. Nonoperative management of complete adductor rupture can provide equal results to surgical repair in terms of return to play in the National Football League. Case series; Level of evidence, 4. Using the National Football League Injury Surveillance System, adductor tendon ruptures documented by magnetic resonance imaging were identified in 19 National Football League players from 1992 to 2004. The team physician for each respective player completed a survey with information about history, physical examination, magnetic resonance imaging findings, treatment, and outcomes. Statistics were analyzed with a Student unpaired t test. Fourteen players were treated nonoperatively, and 5 players were treated with surgical repair using suture anchors. In both groups, all players eventually returned to play in the National Football League. Mean time for return to play was 6.1 +/- 3.1 weeks (range, 3-12 weeks) for the nonoperative group and 12.0 +/- 2.5 weeks (range, 10-16 weeks) for the operative group (P = .001). One player in the operative group suffered the complication of a draining wound and heterotopic ossification. Players represented a variety of positions, and 12 of 19 (63%) had experienced prior symptoms or events. Nonoperative treatment of proximal adductor tendon rupture results in a statistically significantly faster return to play than does operative treatment in athletes competing in the National Football League and avoids the risks associated with surgery while providing an equal likelihood of return to play at the professional level.

  19. Influence of diesel engine combustion on the rupture strength of partially stabilized zirconia

    International Nuclear Information System (INIS)

    Brinkman, C.R.; Begun, G.M.; Cavin, O.B.; Foster, B.E.; Graves, R.L.; Kahl, W.K.; Liu, K.C.; Simpson, W.A.

    1989-01-01

    Results are reported for tests on partially stabilized zirconia (PSZ-TS and MS grade) bars exposed in the combustion chambers of two operating single-cylinder 0.825-L diesel engines. Specifics of test conditions and procedures are presented. Subsequent to exposure, the bars were subjected to four-point bending and the rupture strengths determined. The TS grade showed a decrease in average strength of 32%, while the strength of the MS grade decreased by about 9% in comparison to average behavior of unaged material. Results of X-ray diffraction analysis, Raman spectroscopy, isothermal aging studies, and ceramographic characterization are given to define reasons for material degradation

  20. Creep-rupture behavior of candidate Stirling engine iron supperalloys in high-pressure hydrogen. Volume 2: Hydrogen creep-rupture behavior

    Science.gov (United States)

    Bhattacharyya, S.; Peterman, W.; Hales, C.

    1984-01-01

    The creep rupture behavior of nine iron base and one cobalt base candidate Stirling engine alloys is evaluated. Rupture life, minimum creep rate, and time to 1% strain data are analyzed. The 3500 h rupture life stress and stress to obtain 1% strain in 3500 h are also estimated.