WorldWideScience

Sample records for in-111 wbc scintigrams

  1. Normal distribution of /sup 111/In chloride on scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, K; Machida, K; Hayashi, S; Watari, T; Akaike, A

    1977-05-01

    Indium-111-chloride (/sup 111/InCl/sub 3/) was used as a bone marrow imaging and a tumor-localizing agent in 38 patients (46 scintigrams), who were suspected of, or diagnosed as, having malignant disease, and who were irradiated for malignant disease. The regions of suspected malignant disease, of abnormally accumulated on scintigrams, and the target irradiated, were excluded to estimate the normal distribution of /sup 111/InCl/sub 3/. Scintigrams were taken 48 hrs after intravenous injection of /sup 111/InCl/sub 3/ 1 to 3 mCi. The percent and score distribution of /sup 111/InCl/sub 3/ were noted in 23 regions. As the liver showed the highest accumulation of /sup 111/In on all scintigrams, the liver was designated as 2+. Comparing with the radioactivity in the liver, other regions had similar (2+), moderately decreased (+), or severely decreased (-) accumulation on scintigram. The score is given one for 2+, 0.5 for +, 0 for -. The score and percentage distributions were: liver 100 (100%), lumbar vertebra 58.5 (100%), mediastinum 55 (100%), nasopharynx 50 (100%), testis 47.5 (59%), heart 44.5 (89%), and pelvis 43.5 (78%). Comparing this study with a previous study of /sup 111/In-BLM, score distribution in lumbar vertebra, pelvis, and skull were similar. /sup 111/In-BLM is excreted rapidly after injection, but little /sup 111/InCl/sub 3/ is excreted. Accumulation of /sup 111/In in bone marrow depends upon the amount of /sup 111/In-transferrin in blood. High accumulation in the lumbar vertebra and pelvis shows that /sup 111/InCl/sub 3/ would be effective as a bone marrow imaging agent.

  2. Different cell moieties and white blood cell (WBC) integrity in In-111 labeled WBC preparations

    International Nuclear Information System (INIS)

    Saha, G.B.; Feiglin, D.H.I.; McMahon, J.T.; Go, R.T.; O'Donnell, J.K.; MacIntyre, W.J.

    1985-01-01

    Indium-111 labeled white blood cells (WBC) have become very popular in detecting inflammatory diseases. The purpose of this paper is to determine the distribution of different types of cells in WBC preparation for In-111 oxine labeling, and also to assess the histological integrity of WBC's after labeling with In-111 oxine. Forty to fifty cc of blood was collected from each patient and WBC's were separated by sedimentation and centrifugation. After labeling with In-111 oxine, an aliquot of the WBC sample was used for cell counting and a second aliquot was used for electron microscopic (EM) examination. The different cell moieties were counted, and the mean and standard deviation of twelve determinations calculated. Cells were prepared by the standard technique for electron microscopic examination and images of the cells were obtained at different magnifications (X8,000-25,000). The EM images revealed that although minimal cytoplasmic vacuolization occurred in the WBC's due to the labeling process, the overall histological integrity of the cells remained intact. The relative labeling efficiency of WBC's is greater than those of RBC's and platelets (J Nuc) Med 25:p98, 1984) and, therefore, even a comparatively low population of WBC's gives optimal imaging due to their increased tracer uptake

  3. Pediatric uses of In-111 WBC imaging

    International Nuclear Information System (INIS)

    Samuels, L.D.; Goodgold, H.M.; Hendershott, L.

    1985-01-01

    To evaluate the diagnostic efficacy of In-111 WBC imaging in pediatrics the authors have examined the records of children seen in the laboratory. During the past 4 years they have performed 45 pediatric In-111 WBC studies, half within 1984 alone, in 40 children aged one month to 20 years. In children under one year old they have labelled WBC from 5-10 cc. of the child's blood. They have preferred to transfuse infants after withdrawal of the blood for labelling rather than label donor blood. In twelve children (30%) there was diagnostic localization of labelled WBCs. Five children had equivocal results while three had distinct but false positive localization. The confusing effect of skin lesions of chicken pox and of lymphadenopathy was apparent in six patients. Thirteen children had normal studies. Overall this study of utilization of In-111 WBC in pediatrics suggests best utilization in colitis and abdominal and pelvic infections and in osteomyelitis, especially in distinguishing osteomyelitis from bone infarcts in sickle cell disease. There appears to be lesser utility in patients with palpable adenopathy or superficial infection. Although In-111 WBC imaging may provide clear evidence for active pneumonitis in cases where a chest x-ray is equivocal, such as cytomegalovirus infection, vague localization in bases of lungs, mediastimum or heart is a relatively common finding without known clinical significance

  4. Indium 111 WBC scan in local and systemic fungal infections

    International Nuclear Information System (INIS)

    Haseman, M.K.; Blake, K.; McDougall, I.R.

    1984-01-01

    We describe two patients-one with a systemic fungal infection and one with a localized form-who had strikingly abnormal indium 111 leukocyte (WBC) scans. The patient with systemic disease had an abnormal WBC scan before lesions became clinically apparent

  5. An accurate test for acute appendicitis: In-111 WBC imaging

    International Nuclear Information System (INIS)

    Navarro, D.A.; Weber, P.M.; Kang, I.Y.; dosRemedios, L.V.; Jasko, I.A.

    1985-01-01

    The decision to operate when acute appendicitis (APPY) is suspected is often difficult. Surgeons accept up to a 20% false positive rate to avoid any delay that may result in appendiceal rupture and peritonitis. The authors have successfully improved early diagnostic accuracy by using abdominal imaging beginning 2 hours after injecting In-111 labeled WBC. Patients with clear-cut (APPY) had laparotomy and were not studied. Those who were to be observed in the ER for possible (APPY) had their leukocytes harvested, labeled with In-111 oxine, and reinjected. Abnormal localized activity in the right lower quadrant (RLQ) imaged at 2 hours was graded relative to bone marrow activity (8M): 0, 1+ BM. When available the surgical specimen was imaged for In-111 activity. Of 31 patients studied there were 13 with positive scans for (APPY) all surgically confirmed. There were 4 additional abnormal studies all demonstrating known diagnostic patterns, 2 of pertonitis and 2 of colitis. There were 14 negative studies in 8 of whom the clinical course was benign; the remaining 6 had laparotomy with 3 having (APPY) and 3 not. Thus there were no false positives and 3 false negatives. One case negative at 2 hours had appendiceal activity later. The 3 cases with 3+ activity all had apendiceal abscesses. This new application of In-111 oxine WBC imaging is safe, simple, sensitive and specific. It shortens the time to surgical intervention and should reduce the surgical false positive rate

  6. In-111 WBC imaging in musculoskeletal sepsis

    International Nuclear Information System (INIS)

    Thompson, L.; Ouzounian, T.J.; Webber, M.M.; Amstutz, H.C.

    1984-01-01

    This study evaluated the accuracy and utility of the In-111 labeled WBC imaging in a series of patients who were suspected of having musculoskeletal sepsis. The labeling of the WBCs was patterned after a method previously described, in which the WBCs are labeled with In-111 oxine in plasma. The WBCs from 100 ml of blood are separated and incubated with In-111 oxine complex, and then 500 μCi. of the labeled cells were reinjected into the patient. Images of the areas in question were obtained at 24 hrs. In some instances, 48 hour images were also obtained. Images were interpreted using consistent criteria. Forty imaging procedures were done on 39 patients. These included 39 total joint protheses, and 17 other images to evaluate possible osteomyelitis, septic arthritis or deep abscesses. Of these studies, 15 were positive, and 42 negative. The findings were then correlated with operative culture and pathology in 21, aspiration cultures and gram stains in 14, and with clinical findings in the remaining 21. This correlation showed 41 true negatives, 12 true positives, 1 false negative, and 2 false positives. The sensitivity was 92.9% and the specificity was 95.2%l. The false negative occurred in a patient on chronic suppressive antibiotic therapy for an infected total hip replacement. The false positive images occurred in a patient with active rheumatoid arthritis and in a patient imaged one month post operative placement of the prosthesis. These images were very useful in several septic patients who had many possible sites of infection. The authors conclude that In-III imaging is an accurate and useful non-invasive method of evaluating musculoskeletal sepsis

  7. Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging

    International Nuclear Information System (INIS)

    Knešaurek, K.; Heiba, S.; Kolker, D.; Vatti, S.

    2015-01-01

    The purpose of our study was to correctly fuse MRI and SPECT 111 In WBC and 99m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and 111 In WBC/ 99 m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq 111 In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7±0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. 111 In WBC/ 99 m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. In conclusion, the CT in dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT studies can be used to accurately fuse and compare 111 In WBC/ 99 m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.

  8. In-111 labeled leukocyte scintigraphy in patients with suspected inflammation after failed antibiotic therapy

    International Nuclear Information System (INIS)

    Nasu, Reiko; Akagi, Kiyoshi; Murata, Takashi; Uokawa, Kyousuke; Isoda, Hiroyoshi; Tanaka, Yoshimasa; Itagaki, Yasushi

    1998-01-01

    In-111 labeled leukocyte scintigrapy (In-111 WBC scan) was performed in 16 patients with inflammation suspected on the basis of laboratory findings, symptoms, and diagnostic imaging, but who had failed antibiotic therapy. In-111 WBC scans revealed an abnormal focus of radiotracer activity (positive scans) in five of 16 patients. No correlation was found between the peripheral WBC count and accumulation of In-111 WBC. Inflammatory disease suspected on the basis of the CRP level should be considered when In-111 WBC scanning results in negative findings. Our results indicated that In-111 WBC scanning has low sensitivity after antibiotic therapy. Selection of patients on the basis of persistent elevation of CRP may be valuable. (author)

  9. Negative brain scintigrams in brain tumors

    International Nuclear Information System (INIS)

    Dalke, K.G.

    1978-01-01

    With 53 histologically verified and 2 histologically not identified brain tumors, that showed a negative scintigram, it was tried to find reasons for the wrong and negative dropout of these scintigrams. The electroencephalograms and angiograms, that were made simultaneously were taken into consideration with respect to their propositional capability and were compared with the scintigram findings. For the formation of the negative brain scintigrams there could be found no unique cause or causal constellation. The scintigraphic tumor representation is likely based on a complex process. Therefore the reasons for the negativity of the brain scintigrams can be a manifold of causes. An important role plays the vascularisation of the tumor, but not in a sole way. As well the tumor localisation gains some importance; especially in the temporal lobe or in the deeper structures situated tumors can be negative in the scintigram. To hold down the rate of wrong-negative quote in the case of intracranial tumor search, one is advised to continue with an further exposure after 2 to 4 hours besides the usual exposures, unless a sequential scintigraphy was made from the beginning. (orig./MG) [de

  10. In-111-labeled leukocyte scintigraphy in postoperative joint infection

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Uetani, Masataka; Aziz, A.; Hayashi, Kuniaki

    2000-01-01

    To evaluate the role of In-111-labeled leukocyte scintigraphy in the patients with suspected postoperative joint infection, 41 scintigraphic examinations were performed in 24 patients. Scintigrams were interpreted by the degree of accumulation of labeled leukocytes, and were classified into 3 groups: positive, intermediate, and negative. In the cases of positive leukocyte scans, definite diagnosis of infection was made in all cases except one. In the cases of negative scans, there was no evidence of infection. In 13 cases, leukocyte scintigrams were interpreted in conjunction with bone scintigrams. Definite diagnosis of infection was made in all of the cases with positive combined leukocyte/bone scan, and there was no evidence of infection in cases with negative combined leukocyte/bone scan. This study demonstrates that In-111-labeled leukocyte scintigraphy is a useful method in diagnosis of postoperative joint infection, and accuracy of the examination improves when combined with bone scintigraphy. (author)

  11. Bone marrow scintigraphy using 111Indium chloride in patients with aplastic anemia

    International Nuclear Information System (INIS)

    Mabuchi, Nobuhisa; Kumano, Machiko; Matsumoto, Fumiko; Arita, Shigehiro; Nakagawa, Kenichi; Fujii, Koichi; Yoshioka, Hiroyasu; Hamada, Tatsumi; Ishida, Osamu

    1987-01-01

    Bone marrow scintigraphy using 111 Indium chloride ( 111 In-chloride) was performed in 18 patients with aplastic anemia. The scintigrams were taken 48 hours after an intravenous injection of 111 In-chloride 3 mCi. The distribution patterns on scintigram were classified into 5 types: Type I (4 cases) showed no accumulation, Type II (6 cases) showed low accumulation in usual bone marrow sites. Type III (7 cases) showed island-like distribution in bone marrow sites. Type IV, although no case was included in the 18 patients, shows uneven distribution between pelvis and sternum or vertebrae. Type V (one case) showed almost normal accumulation in usual bone marrow sites. Bone marrow uptake of 111 In-chloride correlated well with the cellularity of bone marrow. There was a tendency for the cases of markedly increased saturated iron-binding capacity to show increased renal activity. In type III, both the percentage of cases who had been treated and the count of reticulocytes were higher than those in the other types, which suggested that island-like distribution on scintigram showed the regeneration responded to the therapy, and related to the erythropoietic function. (author)

  12. Bone marrow scintigraphy using /sup 111/Indium chloride in patients with aplastic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Mabuchi, Nobuhisa; Kumano, Machiko; Matsumoto, Fumiko; Arita, Shigehiro; Nakagawa, Kenichi; Fujii, Koichi; Yoshioka, Hiroyasu; Hamada, Tatsumi; Ishida, Osamu

    1987-12-01

    Bone marrow scintigraphy using /sup 111/Indium chloride (/sup 111/In-chloride) was performed in 18 patients with aplastic anemia. The scintigrams were taken 48 hours after an intravenous injection of /sup 111/In-chloride 3 mCi. The distribution patterns on scintigram were classified into 5 types: Type I (4 cases) showed no accumulation, Type II (6 cases) showed low accumulation in usual bone marrow sites. Type III (7 cases) showed island-like distribution in bone marrow sites. Type IV, although no case was included in the 18 patients, shows uneven distribution between pelvis and sternum or vertebrae. Type V (one case) showed almost normal accumulation in usual bone marrow sites. Bone marrow uptake of /sup 111/In-chloride correlated well with the cellularity of bone marrow. There was a tendency for the cases of markedly increased saturated iron-binding capacity to show increased renal activity. In type III, both the percentage of cases who had been treated and the count of reticulocytes were higher than those in the other types, which suggested that island-like distribution on scintigram showed the regeneration responded to the therapy, and related to the erythropoietic function.

  13. Diagnosis of intra abdominal inflammatory processes with 111In-labelled leucocytes

    International Nuclear Information System (INIS)

    Roevekamp, M.H.; Brummelkamp, W.H.; Schoot, J.B. van der; Reinders Folmer, S.Chr.C.; Royen, E.A. van

    1982-01-01

    Over a two and a half year period, 225 scintigrams with indium-111 oxinate labelled leukocytes were performed in 184 patients suspected of an intra-abdominal, retroperitoneal or pelvic inflammatory process. In patients suspected of an upper abdominal process, an indium-111 leukocyte-99Tc-Sn colloid subtraction was performed, in order to eliminate the normal liver and spleen uptake. 123 Scintigrams were considered true positive and 73 true negative. A diagnostic accuracy of 87% was calculated. With 18 false-positive scans an 80%-specificity and with 11 false-negative a 92%-sensitivity were obtained. False-positive results in the majority of the scintigrams were based on leukocyte accumulations, due to aspecific cellular inflammatory reactions. False-negative results were mainly related to intra-hepatic, intra-splenic or older lesions. In 150 patients, ultrasonography and/or computed tomography was also performed. A higher diagnostic accuracy was observed with leukocyte scintigraphy compared to ultrasonography. (Auth.)

  14. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  15. Indium-111 WBC detection of emphysematous gastritis in pancreatitis

    International Nuclear Information System (INIS)

    Caruana, V.; Swayne, L.C.; Salaki, J.S.

    1990-01-01

    We present a case of emphysematous gastritis initially detected with 111In oxine-labeled white blood cell scintigraphy and subsequently confirmed by computed tomography. Early aggressive antibiotic and supportive therapy resulted in a successful clinical outcome

  16. Pyrophosphate heart scintigram in children with progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Nesvadba, Z; Zdansky, P; Novak, J; Kubicek, J; Kafka, P; Vizda, J; Mazurova, Y

    1984-08-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index.

  17. Positive /sup 111/In-granulocyte scintigraphy in a patient with focal leukemic blast cell infiltrations

    Energy Technology Data Exchange (ETDEWEB)

    Syrjaelae, M; Remes, K; Paavonen, T; Liewendahl, K

    1985-06-01

    A patient with acute myeloid leukemia was investigated with /sup 111/In-granulocyte scintigraphy to reveal possible sites of infection. /sup 111/In-granulocytes accumulated in areas of leukemia blast cell infiltration leading to a false-positive scintigram. This possibility must be kept in mind when studying leukemic patients using labeled leukocytes.

  18. Evaluation of latent cardiac disease in diabetic patients with Tl-201 exercise myocardial scintigram and blood pool scintigram

    International Nuclear Information System (INIS)

    Miyashita, Takeo; Kasai, Ryutaro; Ikebe, Nobuhiko; Nagai, Yoshikazu; Yamasawa, Ikuhiro; Ibukiyama, Chiharu; Notoya, Yoko

    1990-01-01

    To find latent heart disease in diabetic patients, 142 diabetic patients were divided into 4 groups: (1) no hypertension and normal ECG (DM group); (2) hypertension recognized clinically (HT group); (3) myocardial damage on ECG (MD group); (4) group associated with the previous 2 (HT+MD group). In all groups Tl-201 exercise myocardial scintigrams and blood pool scintigrams were taken for comparative analysis. Positive rates of SPECT were 27.7% (23/83) in the DM group, 30.0% (9/30) in the HT group, 50.0% (6/12) in the MD group, and 70.6% (12/17) in the HT+MD group. The rate in the HT+MD group was significantly higher than in that of the DM and HT groups (p<0.001, p<0.01). Blood pool scintigrams revealed that in the HT+MD group, as compared with the normal control group, both 1/3 FF and PFR were significantly depressed, in addition to significant TPF prolongation in the former (p<0.001, p<0.05, p<0.05). These findings suggest that in diabetic patients hypertension and myocardial damage would lead to a high incidence of abnormality in SPECT and left ventricular rapid filling dysfunction. This indicate a high incidence of latent cardiac disease which can be recognized in diabetic patients by stress myocardial and blood pool scintigrams. (author)

  19. Evaluation of pancreatic scintigram in the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Takai, Yukihiro; Ueda, Noriyuki; Takasago, Noritsugu; Minemoto, Hiromasa; Namiki, Masayoshi

    1981-01-01

    The classification of accumulative patterns with the pancreatic scintigram findings of chronic pancreatitis and carcinoma of the pancreas were compared with endoscopic retrograde pancreatography (ERP) findings and Pancreozymin-Secretin test (P-S test). I) The frequency of pancreatic cancer was 93%, whilst, the chronic pancreatitis was 88% in the abnormal pancreatic scintigram. II) In the scintigram the type II (localyzed defect shadows) of pancreatic cancer was comparatively high and it is proportional to evidence. derived from ERP. Localized diagnostic certainty is helpful, although the two tests are related. The P-S test is only restricted to the carcinoma of head, whilst, scintigram is more useful to detect the carcinoma of the body and tail of the pancreas. III) As for the chronic pancreatitis, there are various accumulative patterns. This is resemblance to that of ERP findings, but in the P-S normal test, it showed discrepancy in part of the result. Particularly, in the type I (slightly generalized low uptake with density silhouette) and type II. Therefore in order to obtain an accurate diagnosis, it is essential to have both the P-S test and scintigram. (author)

  20. Investigation and application of pattern recognition techniques to medical picture data (scintigrams)

    Energy Technology Data Exchange (ETDEWEB)

    Vaknine, R; Ammann, W W; Lorenz, W J [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1977-12-01

    The application of pattern recognition techniques to scintigrams is investigated. A preprocessing method which produces the 'curvature scintigram', and a boundary detection algorithm for feature extraction purposes are described. Clinically relevant parameters are then extracted from the bounded count rate scintigram and the curvature scintigram. For classification, the factor analysis of correspondence and the discriminant analysis are used. These procedures are applied to liver scintigrams of 47 patients who have been categorized by biopsy. As the results show, the curvature scintigram and the parameter extraction from the bounded count rate scintigrams improve the quality of the diagnosis and support the crucial distinction between diffuse 'patchy' structures and the presence of a few distinct lesions in scintigrams.

  1. Symbolic reasoning about myocardial scintigrams in PROLOG

    International Nuclear Information System (INIS)

    Rosenberg, S.; Itti, R.; Benjelloun, L.

    1986-01-01

    PROLOG (PROgramming in LOGic) is the declarative programming language at the heart of the Japanese fifth-generation computer project. It is proposed that PROLOG is a suitable tool for symbolic image processing, once standard preprocessing has been done. In the present application, the problem of prediction of coronary anatomy from myocardial scintigrams is addressed. Uncertainty is dealt with by a combination of fuzzy-set theoretic and probabilistic reasoning. Heuristic classification rules are based on clinical experience and on a set of 247 myocardial scintigrams with their corresponding coronary angiograms. (orig.)

  2. Symbolic reasoning about myocardial scintigrams in PROLOG

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, S; Itti, R; Benjelloun, L

    1986-06-01

    PROLOG (PROgramming in LOGic) is the declarative programming language at the heart of the Japanese fifth-generation computer project. It is proposed that PROLOG is a suitable tool for symbolic image processing, once standard preprocessing has been done. In the present application, the problem of prediction of coronary anatomy from myocardial scintigrams is addressed. Uncertainty is dealt with by a combination of fuzzy-set theoretic and probabilistic reasoning. Heuristic classification rules are based on clinical experience and on a set of 247 myocardial scintigrams with their corresponding coronary angiograms.

  3. The pyrophosphate heart scintigram in children with progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Duska, F.; Nesvadba, Z.; Zdansky, P.; Novak, J.; Kubicek, J.; Kafka, P.; Vizda, J.; Mazurova, Y.; Karlova Univ., Hradec Kralove; Karlova Univ., Hradec Kralove

    1984-01-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index. (orig.) [de

  4. Distinction of infected and non-infected post-surgical incisions with In-111-WBC scintigraphy

    International Nuclear Information System (INIS)

    Abdel-Nabi, H.; Hinkle, G.H.; Olsen, J.O.

    1985-01-01

    To determine if In-111-WBCs scintigraphy can distinguish between healing and infection in post-surgical wounds, a prospective study was performed in patients with 3-14 day old surgical incisions. Eighteen patients (11 males and 7 females) were scanned 24 hrs after injection of 0.5 mCi of In-111 labeled autologous leukocytes. The scan findings were correlated with blood and/wound cultures results and diagnosis at time of discharge. Incisional uptake of In-111-WBCs was noted in 9 patients with infected surgical wounds and was absent in those 9 patients with non-infected surgical wounds. The results of the authors' study show that In-111-WBCs do not accumulate in non-infected surgical incisions. This confirms their previous findings in rats. The high specificity of In-111 leukocytes imaging makes it a valuable study in the evaluation of post-operative patients with suspected surgical wound infections. In-111 WBCs scintigraphy can distinguish between normal healing and infection at the site of recent (3-14 days) surgical incisions

  5. 111Indium-labelled leucocyte scintigraphy in the diagnosis of inflammatory disease - first results

    International Nuclear Information System (INIS)

    Rovekamp, M.H.; Hardeman, M.R.; Schoot, J.B. van der; Belfer, A.J.

    1981-01-01

    In 61 patients, 66 scans were performed with 111 In-labelled autologous leucocytes to evaluate this method in the diagnosis of inflammatory disease. All scintigraphic results were compared with clinical, operative or postmortem findings. In the first 20 examinations in 19 patients, 2 scintigrams were true positive, 9 true negative and none false positive, whereas 9 scintigrams had to be considered as false negative. These false negative results were probably due to loss of viability of the labelled cells. A modified labelling technique, in which a much lower concentration of oxine was used, was employed for a further 46 examinations in 42 patients. Twenty-four scintigrams were true positive and 22 true negative, while no false positive or false negative results were observed. These results suggest that this modified technique is useful in the diagnosis of inflammatory disease. (author)

  6. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    International Nuclear Information System (INIS)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.; Webber, M.M.; Amstutz, H.C.

    1987-01-01

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletal sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement

  7. Study on liver scintigram using sup(99m)Tc-Sn colloid

    International Nuclear Information System (INIS)

    Nagase, Katsuya; Maruo, Kuninobu

    1975-01-01

    First of all, the liver scintigram was taken using 198 Au-colloid in cases of liver diseases, especially cases which seemed to have morphological changes in the liver. Of these cases, in cases which were found to have lesions the liver scintigram was subsequently taken using sup(99m)Tc-Sn colloid. In addition, in order to compare the state of lesions in both liver scintigrams with 198 Au-colloid and sup(99m)Tc-Sn colloid, ultrasonic tomogram was taken at each time. The scintigram using sup(99m)Tc-Sn colloid seemed to more clearly reveal the state of lesions and their sizes in the thin liver regions, especially the right border, the lower border and the left lobe in the liver, compared with 198 Au-colloid scintigram. The lesions in the thick liver tissues, especially the central right lobe, sometimes became unclear using sup(99m)Tc-Sn colloid. Therefore, 198 Au-colloid seemed to be available in these lesions. The scintigram using sup(99m)Tc-Sn colloid was found more useful for the diagnosis of lesions of patients with liver, cirrhosis whom the uptake rate of 198 Au-colloid is poor, compared with 198 Au-colloid scintigram. (Namekawa, K.)

  8. Effect of different doses of aerobic exercise on total white blood cell (WBC and WBC subfraction number in postmenopausal women: results from DREW.

    Directory of Open Access Journals (Sweden)

    Neil M Johannsen

    Full Text Available BACKGROUND: Elevated total white blood cell (WBC count is associated with an increased risk of coronary heart disease and death. Aerobic exercise is associated with lower total WBC, neutrophil, and monocyte counts. However, no studies have evaluated the effect of the amount of aerobic exercise (dose on total WBC and WBC subfraction counts. PURPOSE: To examine the effects of 3 different doses of aerobic exercise on changes in total WBC and WBC subfraction counts and independent effects of changes in fitness, adiposity, markers of inflammation (IL-6, TNF-α, C-reactive protein, fasting glucose metabolism, and adiponectin. METHODS: Data from 390 sedentary, overweight/obese postmenopausal women from the DREW study were used in these analyses. Women were randomized to a non-exercise control group or one of 3 exercise groups: energy expenditure of 4, 8, or 12 kcal kg(-1⋅week(-1 (KKW for 6 months at an intensity of 50% VO2peak. RESULTS: A dose-dependent decrease in total WBC counts (trend P = 0.002 was observed with a significant decrease in the 12KKW group (-163.1±140.0 cells/µL; mean±95%CI compared with the control (138.6±144.7 cells/µL. A similar response was seen in the neutrophil subfraction (trend P = 0.001 with a significant decrease in the 12KKW group (-152.6±115.1 cells/µL compared with both the control and 4KKW groups (96.4±119.0 and 21.9±95.3 cells/µL, respectively and in the 8KKW group (-102.4±125.0 cells/µL compared with the control. When divided into high/low baseline WBC categories (median split, a dose-dependent decrease in both total WBCs (P = 0.003 and neutrophils (P<0.001 was observed in women with high baseline WBC counts. The effects of exercise dose on total WBC and neutrophil counts persisted after accounting for significant independent effects of change in waist circumference and IL-6. CONCLUSION: Aerobic exercise training reduces total WBC and neutrophil counts, in a dose-dependent manner, in

  9. Prototype production of the scintigram viewer (SVO-1)

    International Nuclear Information System (INIS)

    Oyamada, Hiyoshimaru

    1975-01-01

    ''Scintigram Viewer'', SVO-1, is designed for reading the scintigram films by enhancing contrast of the pictures. This is composed of a light source, AKAI CVC-150 TV camera (with a zoom lens, Fujinon TV.Z, f:2), AKAI VCS-150 camera control unit and color TV(Sony, Trinitron CVM-1840). The light source is set in a box which has a side-window where the scintigram film is set. The light coming through the film is caught by TV camera where red and blue light are separated, leaving green light not affected. These lights are then sent to AKAI VCS-150 where the gains for red and blue can be adjusted to desirable color as the operator likes for display. After these manual processings, the scintigram film is shown on the color TV. The contrast enhancement can be done by adjusting either picture control on the TV panel or diaphragm of TV camera/or both, and the defocusing can be easily done by changing the focus of the lens. Because the TV camera has a zoom lens as mentioned above, either whole picture or enlarged picture of one area on the film can be displayed. Initially, the author designed this machine to find out cold areas which were easily overlooked by the ordinary manner on the original films. However, after examining many scintigram films by this technique it was found that the search for the hot areas was more suitable with this machine and the whole body bone scintigram was the best so far. For example, the metastatic bone lesion which is not definite on the original sicntigram by nacked eyes can be easily pointed out on the color TV after the abovementioned processings. Now, this machine is working very well and is an important accessory for our daily work. (auth.)

  10. Automatic classification of liver scintigram patterns by computer

    International Nuclear Information System (INIS)

    Csernay, L.; Csirik, J.

    1976-01-01

    The pattern recognition of projection is one of the problems in the automatic evaluation of scintigrams. An algorythm and a computerized programme with the ability to classify the shapes of liver scintigrams has been elaborated by the authors. The programme differentiates not only normal and pathologic basic forms, but performs the identification of nine normal forms described by the literature. To pattern recognition structural and local parameters of the picture were defined. A detailed mechanism of the programme is given in their reports. The programme can classify 55 out of 60 actual liver scintigrams, a result different from subjective definition obtained in 5 cases. These were normal pattern of liver scans. No wrong definition was obtained when classifying normal and pathologic patterns

  11. In-111-labeled leukocyte scintigraphy in suspected orthopedic prosthesis infection: comparison with other imaging modalities

    International Nuclear Information System (INIS)

    Magnuson, J.E.; Brown, M.L.; Hauser, M.F.; Berquist, T.H.; Fitzgerald, R.H. Jr.; Klee, G.G.

    1988-01-01

    When infection of prosthetic orthopedic implants is suspected, optimal management requires accurate confirmation or exclusion of infection. The authors retrospectively studied 98 patients with possible infection who underwent scanning with indium-111-labeled white blood cells (WBCs) and subsequently underwent surgery within 14 days. At surgery, 50 patients had infections, as determined by means of culture or histologic results. The diagnostic accuracy of In-111 scanning was compared with that of plain radiography, arthrography, three-phase bone scanning, and various clinical and laboratory findings classically associated with infection. Positive findings on In-111 WBC scans and elevated erythrocyte sedimentation rates were found to be the most predictive variables in the diagnosis of septic prostheses (P less than or equal to .001 and P less than or equal to .002, respectively). Likelihood ratio analysis more clearly demonstrated the superiority of In-111 WBC scanning, with positive and negative scans yielding likelihood ratios of 5.0 and 0.16, respectively

  12. Rapid, high-efficiency labeling of leukocytes with In-111 after hemolytic removal of erythrocytes

    International Nuclear Information System (INIS)

    Karesh, S.M.; Henkin, R.E.

    1985-01-01

    During the labeling of leukocytes with Indium-111, conventional methodology involves separation and washing to remove red cells. This technique results in the loss of a significant number of leukocytes. Citrated whole blood of ten normal volunteers was studied for an alternate labeling method following sedimentation for 30 to 45 minutes and low speed centrifugation of the leukocyte-rich plasma. The average labeling for these ten volunteers by Indium-111 was 90% versus 60% by the older technique. Viability as measured by the trypan blue exclusion test was greater than 95%, WBC losses were essentially zero, and no WBC clumping was observed. Eighteen patients referred for leukocyte imaging were studied by this method. In this patient population, there was 91% labeling with viability greater than 95% and no evidence of clumping. Less than 5% RBC's were noted in any lot. Indium-111 WBC activity 20 minutes post injection averaged 79% of whole blood activity. This modification results in decreased losses of white cells, reduces preparation time to less than 2 hours, and significantly improves the labeling efficiency of the final product. Liver/spleen ratios and image quality were unchanged from the original method

  13. Classification of scintigrams on the base of an automatic analysis

    International Nuclear Information System (INIS)

    Vidyukov, V.I.; Kasatkin, Yu.N.; Kal'nitskaya, E.F.; Mironov, S.P.; Rotenberg, E.M.

    1980-01-01

    The stages of drawing a discriminative system based on self-education for an automatic analysis of scintigrams have been considered. The results of the classification of 240 scintigrams of the liver into ''normal'', ''diffuse lesions'', ''focal lesions'' have been evaluated by medical experts and computer. The accuracy of the computerized classification was 91.7%, that of the experts-85%. The automatic analysis methods of scintigrams of the liver have been realized using the specialized MDS system of data processing. The quality of the discriminative system has been assessed on 125 scintigrams. The accuracy of the classification is equal to 89.6%. The employment of the self-education; methods permitted one to single out two subclasses depending on the severity of diffuse lesions

  14. Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Allan, R.A.; Bassingham, S.; Lazarus, C.; Clarke, S.E.M.; Fogelman, I.; Sladen, G.E.

    1993-01-01

    Forty-seven patients, 29 with chronic inflammatory bowel disease (IBD) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-III oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h 99m Tc-HMPAO WBC scans showed the same distribution to disease as the 3-h 111 -In WBC scans, with no difference in intensity (P 111 -In scans. The 3-h 99m Tc-HMPAO WBC scans showed more extensive disease (P 111 In WBC scans. Physiological bowel activity on 3-h 99m Tc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, 99m Tc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease. (orig.)

  15. Noninvasive detection of coronary thrombi with 111In platelets: concise communication

    International Nuclear Information System (INIS)

    Bergmann, S.R.; Lerch, R.A.; Mathias, C.J.; Sobel, B.E.; Welch, M.J.

    1983-01-01

    The need for rapid, definitive identification of coronary thrombosis has been intensified by the advent of thrombolytic therapy and by interest in the role of thrombosis in the etiology of coronary artery disease. To determine whether platelet thrombi can be detected noninvasively with 111 In platelets, a method was developed in which /sup 99m/Tc-tagged red blood cells were used to correct for activity within the blood attributable to platelets circulating but not associated with thrombus. In 18 dogs coronary thrombi were induced closed-chest with a copper coil introduced into the coronary artery. 111 In platelets and /sup 99m/Tc RBCs were administered either before or 1 hr after induction of thrombus, and serial scintigrams obtained. Coronary thrombus was identified readily in the processed scintigrams. In six dogs, thrombolysis was achieved with intracoronary streptokinase. In each case serial scintigraphy demonstrated resolution of the clot. The dual radiotracer technique should permit serial noninvasive delineation of the temporal relationship between platelet deposition and coronary heart disease in patients, and should facilitate the evaluation of interventions designed to prevent platelet aggregation or to lyse existing thrombi

  16. Bico 2: second national intercomparison campaign of WBC centres working in Italy; Bico 2: la seconda campagna MIDIA di interconfronto dei WBC operanti in Italia

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni, G. [ENEA, Centro Ricerche `Ezio Clementel`, Bologna (Italy). Dip. Ambiente

    1998-12-31

    During the period November 1994 - May 1995 the coordinating group of WBC centres working in Italy organised the 2. national intercalibration and intercomparison campaign. A BOMAB phantom was used filled with four radionuclides gel solution with gamma energy emissions ranging between 100 keV and 2 MeV. 17 out of 21 Italian WBC centres took part in the campaign. Through the intercalibration, organised according to internationally accepted methodologies, each WBC centre could check its own calibration procedures. many intermediate data, collected for the methodologies and measurement procedures intercomparison, permitted analyses and comparison of uncertainly causes in a WBC measurement of the internal contamination. A proposal of MDA definition and assessment procedure resulted from the intercomparison campaign. [Italiano] Il Coordinamento dei Centri WBC operanti in Italia ha organizzato la seconda campagna di intercalibrazione ed interconfronto nazionale basata sulle misure di un fantoccio BOMAB riempito con una soluzione radioattiva gelificata contenente 4 radionuclidi con emissioni gamma nell`intervallo energetico compreso fra 100 keV e 2 MeV. Alla campagna, che si e` svolta fra novembre 1994 e maggio 1995, hanno partecipato 17 dei 21 Centri WBC censiti in Italia. L`intercalibrazione e` stata organizzata secondo criteri ormai consolidati in campo internazionale ed ha permesso ad ognuno dei partecipanti di verificare le proprie procedure di calibrazione. Per l`interconfronto delle procedure e dei metodi di misura impiegati e` stata raccolta una serie di dati intermedi che hanno consentito di analizzare e confrontare le fonti di incertezza insite nella misura di contaminazione interna nell`uomo tramite WBC. Cio` ha infine reso possibile una proposta di definizione e di procedura di determinazione del valore della minima attivita` rivelabile (MDA) in accordo con le piu` recenti tendenze in campo internazionale.

  17. 99Tcm stannous WBC study in childhood inflammatory bowel disease- what benefit?

    International Nuclear Information System (INIS)

    Howman-Giles, R.; Porn, U.; Peacock, K.; O'Loughlin, E.; Uren, R.

    2000-01-01

    Full text: Inflammatory bowel disease (IBD) is increasingly recognised in the paediatric population. Management requires early diagnosis with determination of disease localisation and intensity. The 99 Tc m labelled white blood cell (WBC) study has been used for IBD in adults but little data is available in children. The most common agent used is 99 Tc m HMPAO however, this is time consuming and expensive. The use of 99 Tc m sulphur colloid labelled WBC is an easy, reliable technique. 70 patients aged 2-19 years (mean 12.7) were studied. Planar and SPECT imaging was performed at one and three hours. 38 patients with proven IBD had positive WBC. Of 32 with negative WBC, five had IBD, however, three were on treatment with steroids. 18 patients had barium radiography (BR): nine (50%) were positive for IBD whereas 18 (100%) were positive on WBC. Comparison with endoscopy showed good correlation of areas involved in 45%, 18% had different areas and 36% had more areas defined on endoscopy. In the latter group 14% had positive endoscopy in the stomach and duodenum, which are area not visualised on WBC studies. The WBC has a sensitivity of 95%, specificity of 100% and accuracy of 93%. For BR the sensitivity was 53%, specificity 100% and accuracy 63%. Conclusion: WBC is a good screening investigation for IBD prior to having other invasive investigations. This study would suggest that the barium radiographic study does not offer additional benefits over the WBC and endoscopy in determining the initial diagnosis and extent of the disease. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. sup(99m)Tc-pyrophosphate and /sup 201/Tl myocardial scintigrams in a patient with myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M.; Nishimura, T.; Shimoto, Y.; Fuzioka, S.; Kobayashi, K. (Shimada City Hospital, Shizuoka (Japan))

    1981-09-01

    Myocardial necrosis in acute myocarditis was investigated by scintigraphy. sup(99m)Tc-pyrophosphate (PYP) and /sup 201/TI myocardial scintigrams were obtained on a patient with acute myocarditis due to mycoplasma infection. sup(99m)Tc-PYP myocardial scintigrams in the acute stage demonstrated grade 2+ findings, which remained until the chronic stage. /sup 201/TI myocardial scintigrams in the acute stage revealed impaired perfusion restricted to the posterolateral wall, and this decrease continued through the chronic stage. It was concluded that both of sup(99m)Tc-PYP and /sup 201/TI myocardial scintigrams can reveal abnormality of acute myocarditis.

  19. Evolution of structure and mechanical properties of hard yet fracture resistant W-B-C coatings with varying C/W ratio

    Czech Academy of Sciences Publication Activity Database

    Alishahi, M.; Mirzaei, S.; Souček, P.; Zábranský, L.; Buršíková, V.; Stupavska, M.; Peřina, Vratislav; Balázsi, K.; Czigany, Z.; Vašina, P.

    2018-01-01

    Roč. 340, č. 4 (2018), s. 103-111 ISSN 0257-8972 R&D Projects: GA MŠk LM2015056 Institutional support: RVO:61389005 Keywords : magnetron sputtering * W-B-C * microstructure * hardness * fracture resistance Subject RIV: JK - Corrosion ; Surface Treatment of Materials OBOR OECD: Coating and films Impact factor: 2.589, year: 2016

  20. Value of the 201-Thallium scintigram in the diagnosis of coronary artery disease in patients with and without myocardial infraction

    International Nuclear Information System (INIS)

    Silber, S.; Klein, U.; Rudolph, W.

    1980-01-01

    The usefulness and limitations of the 201-thallium scintigram in the detection of myocardial hypoperfusions is dependent on the sensitivity, specificity and predictive value of the method. The presence of myocardial hypoperfusion can be diagnosed with certainly from a pathologic scintigram only in the absence of false positive scintigrams. Such a high specificity can be achieved only by desginating markedly positive scintigrams as pathologic findings. This, however, necessarily incurs a reduction in sensitivity. In coronary artery disease with previous myocardial infarction, the sensitivity is primarily dependent on the extent of infarction. In coronary arterx desease with no previous myocardial infarction, the sensitivity of the thallium scintigram in patients with 2-vessel disease was found to be less than that of those with 1-vessel disease and 3-vessel disease. As compared with the exercise ECG, the scintigram was more sensitive only in patients with 1-vessel but less sensitive in those patients with 2-vessel and 3-vessel disease. The thallium scintigram is indicated for patients with atypical chest pain, when angina pectoris cannot be ruled out and when the exercise ECG is borderline or non-interpretable. The thallium scintigram is also indicated for asymptomatic patients with a markedly positive exercise ECG. The thallium scintigram yields no additional information relative to the question of presence or absence of myocardial hypoperfusion in patients with typical angina pectoris. In patients with a history of, but with no electrocardiographic criteria for myocardial infarction, the scintigram seems to be of only limited valued. The thallium scintigram is a valuable adjunct in the assessment of the results of coronary artery bypass surgery provided that a pre-operative study is available for comparison. (orig./MG) [de

  1. Diagnostic value of (111)In-granulocyte scintigraphy in patients with fever of unknown origin

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette

    2002-01-01

    111In-granulocyte scintigraphy is often used as a diagnostic tool in patients with fever of unknown origin (FUO). However, its diagnostic performance has been studied in only a limited number of investigations, with most having been published more than 10 y ago; in addition, a broad range...... and specificity in cases of FUO, when one takes into account that (111)In-granulocyte scintigraphy is not a first-line test. The high predictive value of a scintigram showing negative findings may be especially valuable for ruling out an infectious cause of FUO. Neither peripheral leukocyte count nor CRP levels...

  2. Gastroesophageal reflux after esophageal surgery. Evaluation by means of esophageal transit scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Osamu; Yokoi, Hideki; Maebeya, Shinji and others

    1989-04-01

    By means of esophageal transit scintigram using /sup 99m/Tc-DTPA, 15 patients (13 esophageal carcinomas and 2 cardia carcinomas) were studied, in whom esophagogastric anastomosis was done according to the posterior invagination anastomosis technique we had devised. In all 8 patients with anastomosis at cervical region, gastroesophageal reflux was not seen on both scintigrams before and after meals, and the average pressure gradient of high pressure zone at anastomosis was 39.8 cmH/sub 2/O. In 2 of 7 patients with intrathoracic anastomosis, the scintigram before meals showed severe reflux. and the endoscopic findings showed diffuse and moderate erosion in the esophageal mucosa. The average pressure gradient across the anastomosis was 6.5 cmH/sub 2/O. In these 2 patients, the new fornix with a sharp angle of His was not formed. In the remaining 5 patients with intrathoracic anastomosis, reflux was not seen on the scintigram before meals. However, in 2 of them, the scintigram after meal and endoscopic examination revealed mild reflux and mild esophagitis respectively. Furthermore in one patient very mild reflux was observed only on the scintigram after meals but the endoscopic findings showed the normal esophageal mucosa. In these 5 patients, the average pressure gradient across the anastomosis was 17.0 cmH/sub 2/O, which was significantly higher (p<0.01) than that in 2 patients with severe reflux and was significantly lower (p<0.01) than the mean value of high pressure zone in 8 patients with cervical anastomosis. In conclusion, it is presumed that the formation of a large fornix enough to store food and a sharp angle of His are important factors in maintaining an anti-reflux mechanism. The esophageal transit scintigram was proved to be an excellent technique in detecting and evaluating quantitatively gastroesophageal reflux. (author).

  3. Bone remodelling biomarkers after whole body cryotherapy (WBC) in elite rugby players.

    Science.gov (United States)

    Galliera, Emanuela; Dogliotti, Giada; Melegati, Gianluca; Corsi Romanelli, Massimiliano M; Cabitza, Paolo; Banfi, Giuseppe

    2013-08-01

    Whole body cryotherapy (WBC) consists of a brief exposure to extreme cold air (-110°C) in a controlled chamber and it is applied in sports medicine to improve recovery from musculoskeletal trauma. The aim of this study is to better define the beneficial effect of WCB on the musculoskeletal system of athletes, in particular on bone remodelling. Remodelling osteoimmunological biomarkers OPG, RANKL and RANK were measured after WBC treatment in 10 male rugby players randomly selected from the Italian National team. OPG levels were increased significantly, supporting the view that WBC induces an osteogenic effect. Further studies evaluating the effect of WBC on bone metabolism are desirable. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Edwardsiella tarda Endocarditis Confirmed by Indium-111 White Blood Cell Scan: An Unusual Pathogen and Diagnostic Modality

    Directory of Open Access Journals (Sweden)

    Kayleigh M. Litton

    2016-01-01

    Full Text Available Edwardsiella tarda is a freshwater marine member of the family Enterobacteriaceae which often colonizes fish, lizards, snakes, and turtles but is an infrequent human pathogen. Indium-111- (111In- labeled white blood cell (WBC scintigraphy is an imaging modality which has a wide range of reported sensitivity and specificity (from 60 to 100% and from 68 to 92%, resp. for diagnosing acute and chronic infection. We describe a case of suspected E. tarda prosthetic aortic valve and mitral valve endocarditis with probable vegetations and new mitral regurgitation on transthoracic and transesophageal echocardiograms which was supported with the use of 111In-labeled WBC scintigraphy.

  5. Bico 2: second national intercomparison campaign of WBC centres working in Italy

    International Nuclear Information System (INIS)

    Castellani, C.M.; Battisti, P.; Tarroni, G.

    1998-01-01

    During the period November 1994 - May 1995 the coordinating group of WBC centres working in Italy organised the 2. national intercalibration and intercomparison campaign. A BOMAB phantom was used filled with four radionuclides gel solution with gamma energy emissions ranging between 100 keV and 2 MeV. 17 out of 21 Italian WBC centres took part in the campaign. Through the intercalibration, organised according to internationally accepted methodologies, each WBC centre could check its own calibration procedures. many intermediate data, collected for the methodologies and measurement procedures intercomparison, permitted analyses and comparison of uncertainly causes in a WBC measurement of the internal contamination. A proposal of MDA definition and assessment procedure resulted from the intercomparison campaign [it

  6. Observation on scintigram of bone tumors by color data system

    International Nuclear Information System (INIS)

    Minami, Kyuman

    1982-01-01

    The uptake of RI on bone scintigram was converted with a color data system to a color pattern of 12 colors. The color patterns of bone tumors were analysed in comparison them with those in contralateral part of body. The author observed on color patterns of bone scintigrams in 70 cases of bone tumors, of which 28 cases were malignant, 32 benign and 10 giant cell tumors. Differences of color pattern were found relatively low in tumors of the pelvis, whereas they were high in tumors of the limbs and shoulder. In malignant tumors, differences of the color patterns were marked and wide in range. Applying the color data system to bone scintigram, bone tumors could be objectively observed and the method was very helpful for diagnosis of bone tumors. (author)

  7. The value of bone scintigram in elderly subjects

    International Nuclear Information System (INIS)

    Tanno, Munehiko; Yamada, Hideo; Hayashida, Koichi; Endoh, Kazuo; Nagashima, Junichi; Yamagata, Atsushi; Nishino, Hideo; Chiba, Kazuo

    1986-01-01

    To evaluate increased bone uptake of radionuclides at lumbar vertebra in elderly subjects, comparative study of bone scintigram with CT findings and autopsy finding of bone were performed. Incidence of abnormal increased bone uptake were 59 % in neoplastic disease group, while 50 % in benign disease group, respectively. Bone uptake of radionuclides to thoracic and lumbar vertebrae revealed marked high incidence even in both group. 13 out of 25 cases which revealed bone uptake at lumbar vertebrae in malignant disease group showed metastatic bone lesions and the rest of these cases did not show no apparent macroscopic metastatic bone lesions. In comparative study with CT findings of 18 cases most cases revealed osteosclerotic and osteoperotic changes of bone and fracture on CT imaging at the sites where bone uptake of radionuclides were observed. Thus, these evidence support that ageing process of bone must be considered as important factors to evaluate bone scintigram imaging in elderly subjects. (author)

  8. Indium-111-labeled white blood cells in the detection of osteomyelitis complicated by a pre-existing condition

    International Nuclear Information System (INIS)

    McCarthy, K.; Velchik, M.G.; Alavi, A.; Mandell, G.A.; Esterhai, J.L.; Goll, S.

    1988-01-01

    Forty-six patients (23M, 23F) ranging in age from 19 to 79 yr with a clinical history of a nonunion fracture, surgery, diabetes or a soft-tissue infection were studied with [ 111 In]oxine WBCs to detect osteomyelitis. There were 27 true-positive, nine true-negative, two false-positive and one false-negative. The false-positives and the false-negative occurred in patients with soft-tissue infections overlying the area of interest. All diagnoses were confirmed by intraoperative bone biopsies and cultures. Bone biopsy and scan were performed within 2 days of each other in 39 patients. The overall sensitivity was 97% (27/28), specificity, 82% (9/11) and the diagnostic accuracy, 92% (36/39). The remaining seven patients had negative [ 111 In]WBC scans several months after positive bone biopsies and definite antibiotic treatment. This suggests that [In]WBC scans become negative after appropriate therapy is undertaken. Interobserver data was obtained from four nuclear physicians of varying experience blinded to clinical information. A high degree of agreement was found in over 90% of the cases. This study demonstrates the utility of [ 111 In]WBC scans in the diagnosis and follow-up of complicated osteomyelitis and a high level of interobserver agreement in scan interpretation

  9. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  10. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  11. Comparison of simultaneous [sup 99m]Tc-HMPAO and [sup 111]In oxine labelled white cell scans in the assessment of inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Allan, R.A.; Bassingham, S.; Lazarus, C.; Clarke, S.E.M.; Fogelman, I. (Guy' s Hospital, London (United Kingdom). Dept. of Nuclear Medicine); Sladen, G.E. (Guy' s Hospital, London (United Kingdom). Dept. of Gastroenterology)

    1993-03-01

    Forty-seven patients, 29 with chronic inflammatory bowel disease (IBD) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-III oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h [sup 99m]Tc-HMPAO WBC scans showed the same distribution to disease as the 3-h [sup 111]-In WBC scans, with no difference in intensity (P<0.92); they showed more extensive disease (P<0.02) and more intense uptake (P<0.001) than did the 1-h [sup 111]-In scans. The 3-h [sup 99m]Tc-HMPAO WBC scans showed more extensive disease (P<0.002), with greater intensity (P<0.0005), than did the 3-h [sup 111]In WBC scans. Physiological bowel activity on 3-h [sup 99m]Tc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, [sup 99m]Tc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease. (orig.).

  12. Tomographic thallium-201 myocardial perfusion scintigrams after maximal coronary artery vasodilation with intravenous dipyridamole: comparison of qualitative and quantitative approaches

    International Nuclear Information System (INIS)

    Francisco, D.A.; Collins, S.M.; Go, R.T.; Ehrhardt, J.C.; Van Kirk, O.C.; Marcus, M.L.

    1982-01-01

    Eighty-six patients had thallium-201 ( 201 Tl) myocardial perfusion scintigrams after intense coronary artery dilation with i.v. dipyridamole. Tomographic and planar 201 Tl scintigrams were obtained in each patient. Tomographic scintigrams were interpreted using quantitative or visual criteria; planar scintigrams were assessed using visual criteria only. When visual criteria were used, interobserver variability was 40% for tomographic scintigrams and 44% for planar scintigrams. In the 24 patients with normal or nonsignificant CAD, quantitative analysis of the tomograms (range approach) indicated that one of 24 (4%) had a positive image (specificity 96%%); in contrast, when visual criteria were used to interpret the tomographic or planar 201 Tl scintigrams, eight of 24 (33%) had positive scintigrams (specificity 67%). In the 51 abnormal patients, the sensitivity of detecting CAD was 46 of 51 (90%) for tomographic scintigrams interpreted quantitatively, 39 of 51 (76%) for tomographic scintigrams interpreted visually and 41 of 51 (80%) for planar scintigrams assessed visually. The tomographic imaging procedure (quantitative interpretation) also demonstrated a high sensitivity (89%) and specificity (100%) in 28 patients (10 normal and 18 CAD), with a clinical diagnosis of unstable angina pectoris. Overall, the predictive accuracy of an abnormal scintigram with quantitative tomographic imaging (98%) was significantly better (p<0.05) than either qualitative planar or pinhole imaging

  13. Clinical application of a liver scintigram using sup(99m)Tc-phytate

    International Nuclear Information System (INIS)

    Ishii, Katsumi; Yamada, Nobuaki; Tominaga, Shin-ichi; Kobayashi, Takeshi; Nakazawa, Keiji

    1979-01-01

    Liver scintigrams using sup(99m)Tc-phytate (phytate kit for labeling sup(99m)Tc) were made in 35 patients with hepatitis, 32 patients suspected of having metastatic cancer of the liver, 7 patients with cirrhosis of the liver, and 15 patients with other liver diseases. The scintigrams revealed images which seemed to be cirrhosis of the liver in 15 of the 35 patients with hepatitis and specific images in the 7 with cirrhosis of the liver (including a definitely accumulated image which revealed primary hepatic cancer in 1 patient). They also revealed spaceoccupying lesions which seemed to be metastatic cancer of the liver in 13 of the 32 patients suspected of having this disease. In addition to these findings, clinical findings confirmed the disease. Scintigrams revealed a definitely accumulated image in 1 patient with primary hepatic cancer. During examination, no side effect was observed. The scintigrams seemed to show favorable images of the liver and sup(99m)Tc-phytate seemed to be useful for diagnosing liver diseases. (Namekawa, K.)

  14. In vivo assessment of 111In-labeled hematoporphyrin derivative in breast tumor-bearing animals

    International Nuclear Information System (INIS)

    Wong, D.W.; Mandal, Ashis; Brown, Jerry; Reese, I.C.; Siegler, Richard; Hyman, Shigeyo

    1989-01-01

    The biological behavior of 111 In-labeled HPD has been investigated in tumor-bearing animals. Mice mammary adenocarcinomas and 7,12-dimethylbenz(a)anthracine induced breast tumors in Sprague-Dawley female rats were clearly visualized by 111 In-HPD nuclear scintigraphy. Optimal scans were obtained after a 48 h delay. In normal and tumor-bearing animals, the highest uptake of 111 In-HPD 72 h post-injection was found in the liver, the spleen and the kidneys. Depending on the size and the extent of necrosis, the uptake of 111 In-HPD by malignant breast tumors varied from 2.5% injected dose (ID) in mice to 1% ID in rats. Benign breast tumor uptake of 111 In-HPD was less than 1% ID. No significant amount of the radiopharmaceutical was found in pulmonary abscesses and abdominal cysts. Scintigrams of these infectious or inflammatory lesions were normal. Malignant tumor to blood, heart and lung ratios averaged 50:1, 10:1 and 3:1 respectively. Tumor to brain ratio ranged from 72 to 444:1. (author)

  15. Chronic bacterial osteomyelitis: prospective comparison of 18F-FDG imaging with a dual-head coincidence camera and 111In-labelled autologous leucocyte scintigraphy

    International Nuclear Information System (INIS)

    Meller, J.; Siefker, U.; Lehmann, K.; Meyer, I.; Schreiber, K.; Altenvoerde, G.; Becker, W.; Liersch, T.

    2002-01-01

    Indium-111-labelled white blood cells ( 111 In-WBCs) are currently considered the tracer of choice in the diagnostic work-up of suspected active chronic osteomyelitis (COM). Previous studies in a limited number of patients, performed with dedicated PET systems, have shown that [ 18 F]2'-deoxy-2-fluoro-D-glucose (FDG) imaging may offer at least similar diagnostic accuracy. The aim of this prospective study was to compare FDG imaging with a dual-head coincidence camera (DHCC) and 111 In-WBC imaging in patients with suspected COM. Thirty consecutive non-diabetic patients with possible COM underwent combined skeletal scintigraphy (30/30 patients), 111 In-WBC imaging (28/30 patients) and FDG-PET with a DHCC (30/30 patients). During diagnostic work-up, COM was proven in 11/36 regions of suspected skeletal infection and subsequently excluded in 25/36 regions. In addition, soft tissue infection was present in five patients and septic arthritis in three. 111 In-WBC imaging in 28 patients was true positive in 2/11 regions with proven COM and true negative in 21/23 regions without further evidence of COM. False-positive results occurred in two regions and false-negative results in nine regions suspected for COM. Most of the false-negative results (7/9) occurred in the central skeleton. If the analysis was restricted to the 18 regions with available histology (n=17) or culture (n=1), 111 In-WBC imaging was true positive in 2/18 regions, true negative in 8/18 regions, false negative in 7/18 regions and false positive in 1/18 regions. FDG-DHCC imaging was true positive in 11/11 regions with proven COM and true negative in 23/25 regions without further evidence of COM. False-positive results occurred in two regions. If the analysis was restricted to the 19 regions with available histology (n=18) or culture (n=1), FDG-DHCC imaging was true positive in 9/9 regions with proven COM and true negative in 10/10 regions without further evidence of COM. It is concluded that FDG

  16. Whole body bone scintigram with sup(99m)Tc-phosphate compounds

    International Nuclear Information System (INIS)

    Oyamada, Hiyoshimaru; Orii, Hirotake; Tabei, Toshio; Ishibashi, Hiroyoshi.

    1975-01-01

    Among the compounds of four different types, which are sup(99m)Tc-polyphosphate suppled by A Company, sup(99m)Tc-pyrophosphate by B Company, and sup(99m)Tc-pyrophosphate of electrolysis method and sup(99m)Tc-diphosphonate by C Company, sup(99m)Tc-diphosphonate showed the most favorable result with a constantly good scintigram quality. The remaining three compounds were found also favorable for clinical application. Besides these are undesirable accumulations, rather low energy of sup(99m)Tc-causes different pictures upon the anterior and the posterior views, and previously irradiated area shows a decreased uptake of these compounds. The usefulness of whole body scintigrams in the detection of metastatic bone tumors was also discussed. There was a definite superiority with this technique over the conventional X-ray study. Especially, in thoracic vertebrae, pelvic bone, and ribs, far many diseased areas were detected on the scintigrams than the areas which the physicians noticed or suspected the metastases. As a conclusion, although there are some problems on the scintigrams, it can be said that sup(99m)Tc-phosphate compounds are very useful in detection of metastatic bone tumors, especially with the help of whole body scanner. (JPN)

  17. Clinical efficacy of the liver scintigram

    International Nuclear Information System (INIS)

    Katsuyama, Naofumi; Kawakami, Kenji; Machida, Kikuo.

    1983-01-01

    Liver scintigrams of 406 cases were interpreted by 11 physicians. The ratios of the interpretation of the physiologically decreased activity areas in the liver scintigrams were 27% in the regions of the porta hepatis, 23% in the gall bladder fossa, 20% in the inferior vena cava, 7% in the renal impression, 2% in the portal vein, 2% in the rib impression and 2% in others. The cases having space occupying lesions showed decreased ratio of the interpretation of the physiologically decreased activity areas, as compared with other groups. Cases of the liver cirrhosis showed decreased ratio in the region of inferior vena cava. Cases using Anger camera demonstrated more increased ratio than cases using a scanner. The 11 physicians could be devided for two groups. One group showed high ratios of the interpretation of the physiologically decreased activity areas, and another group showed very low ratio, because of the different interpretation about the physiologically decreased activity areas in the two groups. In our cases, a very few cases showing decreased activity on the liver image were false positive or false negative for diagnosis of space occupying lesions. (author)

  18. Computer-enhanced thallium scintigrams in asymptomatic men with abnormal exercise tests

    International Nuclear Information System (INIS)

    Uhl, G.S.; Kay, T.N.; Hickman, J.R. Jr.

    1981-01-01

    The usefulness of computer-enhanced thallium-201 myocardial perfusion scintigraphy in excluding the diagnosis of coronary artery disease in asymptomatic patients showing abnormal exercise electrocardiograms is evaluated. Multigated thallium scans were obtained immediately following and 3 or 4 hours after maximal exercise testing in 191 consecutive asymptomatic Air Force aircrew members who had shown abnormal exercise electrocardiograms and who were due to undergo coronary angiography. Computer enhancement of the raw images is found to lead to four false positive and two false negative scintigrams as revealed by angiographic results, while the group of 15 with subcritical coronary disease exhibited equivocal results. Results reveal that enhanced thallium scintigrams are an accurate diagnostics tool in detecting myocardial ischemia in asymptomatic patients and may be used in counseling asymptomatic patients on their likelihood of having coronary artery disease

  19. Comparison between 67-gallium citrate of exametazine-T-99m labelled leucocites and the DTPA-indio-111 labelled G immunoglobuline in the diagnosis of bone and articular infections

    International Nuclear Information System (INIS)

    Ramos, Paulo Alberto de Lima; Martin-Comin, Josep; Roca, Manel; Ricart, Ivone; Castell, Manuel; Mora, Jaume; Puchal, Rafael; Ramos, Miguel

    2000-01-01

    The aim of this study was to compare the ability of 67-Gallium citrate (67Ga), 99m-Tc labelled leucocytes (99mTc-WBC) and 111-In-labelled immunoglobulin G (111In-IgG) scintigraphy in bone and joint infections diagnosis. Fifty-six patients were studied. For all patients a bone scan using 99mTc-MDP was indicated. The patients were randomized allocated for 67Ga (Group 1 - 22 patients) or simultaneous administration 99mTc-labelled leucocytes and 111In-IgG.(Group 2 - 34 patients) study. For the groups 1 and 2 were confirmed respectively 12/26 y 11/34 septic lesions. The 67Ga scintigraphy showed 6 true-positive, 9 true-negative, 5 false-positive and 6 false-negative. With 99mTc-WBC, the respective values were 8, 18, 5 and 3. With 111In-IgG, the figures were 7, 17, 6 and 4, respectively. The sensitivity, specificity and accuracy were 50%, 64,3% and 57,7% respectively for the 67Ga, 72,7%, 78,2% and 76,4% respectively for 99mTc-WBC and 63,6%, 73,9% and 70,6% respectively for 111In-IgG. In this study, the labelled leucocytes scintigraphy showed more accurate than 67Ga and 111In-IgG scans for the diagnosis of bone and joint infections. However, the obtained results were less reliable for the diagnosis of occult sepsis in the patients with joint prosthesis (Au)

  20. Indium-111 platelet scintigraphy in carotid disease

    International Nuclear Information System (INIS)

    Branchereau, A.; Bernard, P.J.; Ciosi, G.; Bazan, M.; de Laforte, C.; Elias, A.; Bouvier, J.L.

    1988-01-01

    Forty-five patients (35 men, 10 women) undergoing carotid surgery had Indium-111 platelet scintigraphy as part of their preoperative work-up. Imaging was performed within three hours after injection of the Indium-111. A second series of views was obtained 24 hours later and repeated at 24 hour intervals for two days. Of 54 scintigrams, 22 were positive and 32 negative. Positive results were defined as a twofold or more increase in local activity on a visualized carotid after 24 hours. The sensitivity of the method was 41%, intraoperatively, and the specificity, 100%. The low sensitivity places this method behind sonography and duplex-scanning for screening patients for surgery. We believe that indications for platelet scintigraphy are limited to: 1. Repeated transient ischemic attacks in the same territory with minimal lesions on arteriography and non-homogeneous plaque on duplex scan; 2. Symptomatic patients being treated medically as a possible argument for surgery; 3. Determining therapeutic policy for patients having experienced a transient ischemic attack with a coexisting intracardiac thrombus

  1. Comparison between 67-gallium citrate of exametazine-T-99m labelled leucocites and the DTPA-indio-111 labelled G immunoglobuline in the diagnosis of bone and articular infections; Comparacion del citrato de galio-67 de los leucocitos marcados con exametazina-tecnecio-99m y de la inmunoglobulina G marcada con DTPA-indio-111 en el diagnostico de infecciones oseas y articulares

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Paulo Alberto de Lima [Departamento de Ciencias Basicas da Saude. Universidade Federal da Paraiba. Campina Grande (Brazil); Martin-Comin, Josep; Roca, Manel; Ricart, Ivone; Castell, Manuel; Mora, Jaume; Puchal, Rafael; Ramos, Miguel [Servicio de Medicina Nuclear, Hospital Princeps d' Espanya. Universidad de Barcelona. Feixa Llarga s/n, 08907. Barcelona (Spain)

    2000-01-01

    The aim of this study was to compare the ability of 67-Gallium citrate (67Ga), 99m-Tc labelled leucocytes (99mTc-WBC) and 111-In-labelled immunoglobulin G (111In-IgG) scintigraphy in bone and joint infections diagnosis. Fifty-six patients were studied. For all patients a bone scan using 99mTc-MDP was indicated. The patients were randomized allocated for 67Ga (Group 1 - 22 patients) or simultaneous administration 99mTc-labelled leucocytes and 111In-IgG.(Group 2 - 34 patients) study. For the groups 1 and 2 were confirmed respectively 12/26 y 11/34 septic lesions. The 67Ga scintigraphy showed 6 true-positive, 9 true-negative, 5 false-positive and 6 false-negative. With 99mTc-WBC, the respective values were 8, 18, 5 and 3. With 111In-IgG, the figures were 7, 17, 6 and 4, respectively. The sensitivity, specificity and accuracy were 50%, 64,3% and 57,7% respectively for the 67Ga, 72,7%, 78,2% and 76,4% respectively for 99mTc-WBC and 63,6%, 73,9% and 70,6% respectively for 111In-IgG. In this study, the labelled leucocytes scintigraphy showed more accurate than 67Ga and 111In-IgG scans for the diagnosis of bone and joint infections. However, the obtained results were less reliable for the diagnosis of occult sepsis in the patients with joint prosthesis (Au)

  2. A simple method of digitizing analog scintigrams for quantification and digital archiving

    International Nuclear Information System (INIS)

    Schramm, M.; Kaempfer, B.; Wolf, H.; Clausen, M.; Wendhausen, H.; Henze, E.

    1993-01-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.) [de

  3. [A simple method of digitizing analog scintigrams for quantification and digital archiving].

    Science.gov (United States)

    Schramm, M; Kämpfer, B; Wolf, H; Clausen, M; Wendhausen, H; Henze, E

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on x-ray film were then digitized secondarily by three different methods: 300 dpi flat-bed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification.

  4. Limitations in the use of indium-111-oxine-labeled leucocytes for the diagnosis of occult infection in children

    Energy Technology Data Exchange (ETDEWEB)

    Haentjens, M.; Piepsz, A.; Perlmutter-Cremer, N.; Schell-Frederick, E.; Fruehling, J.

    1987-02-01

    Fifteen children underwent scintigraphy with indium 111 (/sup 111/In)-labeled white blood cells (WBC) for the detection of a local suppuration. The procedure generally contributed to a correct diagnosis. False negative results were observed in 5 children, but in two of them positive foci were also present. The missed lesions were 2 liver abscesses, 1 lung abscess, foci of osteomyelitis and 1 pericarditis. Two cases of chronic granulomatous disease are presented in which increased leucocyte accumulation was not observed in proven instances of infection.

  5. Correlation of 111In-labeled leukocyte scintigraphy with clinical and laboratory findings

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Kitakata, Yuusuke; Uno, Kimiichi; Minoshima, Satoshi; Arimizu, Noboru.

    1993-01-01

    This study evaluated the relationship between 111 In-labeled leukocyte scintigraphy and clinical information and laboratory findings in 24 patients with bone infection and 35 patients with abdominal infection. Fifty-nine scintigrams were retrospectively reviewed and classified into positive or negative results. As the laboratory findings, C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR) at 60 minutes, and peripheral blood leukocyte counts (WBCC) were evaluated. Clinical information such as presence of fever and administration of antibiotics was also compared. No significant relationship between the scintigraphic results and clinical as well as laboratory findings was observed in bone infection patients. CRP levels in positive scintigraphic patients were significantly higher than those in negative scintigraphic patients in the abdominal infection group, otherwise the other indices were not correlated with the scintigraphic results. A few patients with slightly increased CRP (mostly chronic cases) did not show positive scintigrams, suggesting an increased false negative rate of leukocyte scintigraphy in such circumstances. These results suggest that it is inappropriate to determine the application of leukocyte scintigraphy depending on clinical as well as laboratory findings, and leukocyte scintigraphy would yield additional information different from other indices when evaluating inflammatory foci. (author)

  6. Classification of bone scintigrams in hemodialysis patients

    International Nuclear Information System (INIS)

    Ishibashi, Kazunari; Miyamae, Tatsuya

    1985-01-01

    Bone scintigrams from a total of 75 hemodialysis patients using sup(99m)Tc-methylene-diphosphonate (MDP) were classified into two groups; Group I (56 patients) in which the uptake of the radioactivity appeared to be relatively high in the soft tissue and low in the bone, and Group II (19 patients) in which high uptake in the bone and low uptake in the soft tissue were observed. Patients in Group I were further classified into two subgroups; Group I sub(A) (articular type, 21 patients) which was characterized by relatively high uptake into the joint, and Group I sub(B) (reduction type, 35 patients) where uptake was faint in the whole region of the bone. The classification of patients in Group II was also performed; Group II sub(A) (spinal type, 14 patients) where high spinal uptake was observed, and Group II sub(B) (cranio-facial type, 5 patients) where high uptake into the cranio-facial region was observed. The results were compared with 146 subjects with normal bone scintigram in terms of the ratio of bone to soft tissue uptake (B/S ratio) for the cranial bone, jaw bone, lumbar vertebra and femoral bone, and the ratio of epiphysis to diaphysis uptake (E/D ratio) for the femoral bone. The B/S ratio was low in Group I and high in Group II for the bone studied, and the E/D ratio was markedly high in Group I sub(A). Histobiochemical examination indicated that patients in Group I sub(A) and Group II may have osteomalacia and secondary hyperparathyroidism, respectively. It was considered that the visual classification and semiquantitative study as described here were useful for evaluating the pathological condition of renal osteodystrophy. (author)

  7. Classification of bone scintigrams in hemodialysis patients

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Kazunari; Miyamae, Tatsuya

    1985-03-01

    Bone scintigrams from a total of 75 hemodialysis patients using /sup 99m/Tc-methylene-diphosphonate (MDP) were classified into two groups; Group I (56 patients) in which the uptake of the radioactivity appeared to be relatively high in the soft tissue and low in the bone, and Group II (19 patients) in which high uptake in the bone and low uptake in the soft tissue were observed. Patients in Group I were further classified into two subgroups; Group I sub(A) (articular type, 21 patients) which was characterized by relatively high uptake into the joint, and Group I sub(B) (reduction type, 35 patients) where uptake was faint in the whole region of the bone. The classification of patients in Group II was also performed; Group II sub(A) (spinal type, 14 patients) where high spinal uptake was observed, and Group II sub(B) (cranio-facial type, 5 patients) where high uptake into the cranio-facial region was observed. The results were compared with 146 subjects with normal bone scintigram in terms of the ratio of bone to soft tissue uptake (B/S ratio) for the cranial bone, jaw bone, lumbar vertebra and femoral bone, and the ratio of epiphysis to diaphysis uptake (E/D ratio) for the femoral bone. The B/S ratio was low in Group I and high in Group II for the bone studied, and the E/D ratio was markedly high in Group I sub(A). Histobiochemical examination indicated that patients in Group I sub(A) and Group II may have osteomalacia and secondary hyperparathyroidism, respectively. It was considered that the visual classification and semiquantitative study as described here were useful for evaluating the pathological condition of renal osteodystrophy.

  8. Bone marrow scintigraphy with 111In-chloride

    International Nuclear Information System (INIS)

    Kan, Masayasu; Miyamae, Tatsuya

    1977-01-01

    111 In-chloride as a useful bone marrow-scanning agent has been used for various hematological diseases. We also have studied the distribution of indium-111 by scintigraphy in 28 patients with systemic hematopoietic disorders and other: 4 with aplastic anemia, 8 with leucemia, 3 with iron-deficiency anemia, one with pernicious anemia, 2 with myelofibrosis, 3 with multiple myeloma, one with malignant lymphoma, 3 with liver cirrhosis or Banti-syndrome and 3 with seminoma received post operative irradiation. The results of scintigraphy (the image of bone marrow, liver, spleen, kidney and intestine) were compared with bone marrow biopsies, ferrokinetic data and Se.I./TIBC. The bone marrow image was interpreted on a three-point scale: normal distribution of activity (+), abnormal distribution (+-), body back ground level (-). In the cases of iron-deficiency anemia and pernicious anemia with hyperplastic erythroid marrow, regardless of its severe anemia, the scintigrams showed clearly delineated bone marrow images and normal organ distribution of indium. On the other hand, the scan images revealed severe suppressions of bone marrow activity and markedly increased renal activity in some cases of aplastic anemia, acute leucemia and malignant lymphoma with hypoplastic and/or tumour-cell infiltrative marrows. Thus, it may be said that the bone marrow uptake of indium-111 correlates well with the degree of erythroid elements, no correlation with nucleated cell counts, and there is a strong tendency to increased renal activity in the cases of markedly decreased erythropoietic cell counts. (auth.)

  9. Evaluation of a positioning method for equine lateral stifle scintigrams

    Directory of Open Access Journals (Sweden)

    Mathis Marion

    2012-06-01

    Full Text Available Abstract Background The current lack of a standardized protocol for positioning of the gamma camera relative to the horse limb in a lateral stifle scintigram, and thus the reliance on subjective positioning, may be a cause of diagnostic error and inter-operator variability due to variations of the view angle. The aims of this study were to develop a reliable method to obtain a lateral scintigram of the equine stifle based on fixed anatomical landmarks and measure the resulting foot to gamma camera angle on sequential measurements of the same horse and of different horses Methods Technetium filled capsules were glued on the skin on sites adjacent to the origin of the medial and lateral femorotibial collateral ligaments in 22 horses using ultrasound guidance. A lateral view of the stifle was defined as the image where the two radioactive point sources were aligned vertically (point sources guided method. Five sequential lateral acquisitions (one to five of the stifle with the point sources vertically aligned were acquired in each horse, and the angle between the mid-sagittal foot-axis and the vertical axis of the gamma camera (FC angle was measured for each of these acquisitions Results For acquisition group one to five, the mean of the means FC angle was 91.6 ± 2° (2SD and the coefficient of variation (COV was 1.1%. In the 22 horses the 95% CI for the mean FC angles was 91.6° ± 12.1° (2SD and the COV was 6.6%. Conclusions The use of point sources to guide gamma camera position results in less variation in the lateral scintigram than if the distal limb is used as guidance due to a difference in FC angle between horses. The point source guided positioning method is considered suitable as a reference standard method to obtain lateral scintigrams of the equine stifle, and it will be of value in clinical scintigraphy and research. The use of alignment of specifically located point sources may also be applied in other regions to

  10. Segmental quantitative analysis of digital thallium-201 myocardial scintigrams in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Wainwright, R.J.; Maisey, M.N.; Sowton, E.

    1981-01-01

    One hundred and forty-nine patients with suspected ischaemic heart disease were evaluated by exercise thallium-201 myocardial scintigraphy ( 201 Tl SMS), single lead exercise electrocardiography, and coronary arteriography. Myocardial distribution of tracer was assessed semi-quantitatively from digital 201 Tl scintigrams and compared with tracer distribution in subjects with normal hearts. Fifty-two of 54 (96%) patients with normal coronary arteries had normal myocardial scintigrams whereas three patients had a positive ischaemic exercise electrocardiogram and were scan normal. Conversely, 36 of 95 (38%) patients with coronary artery disease had a positive ischaemic electrocardiogram compared with 94 of 95 (99%) patients who had a positive myocardial scintigram. Disease was predicted correctly in 76 out of 80 (95%) of left anterior descending coronary stenoses, in 48 out of 64 (75%) of right coronary artery stenoses, and in 55 out of 64 (85%) of left circumflex coronary artery stenoses, despite the presence of infarcted myocardium in other territories. 201 Tl SMS with segmental quantitative analysis is a highly sensitive and specific technique in the diagnosis of coronary artery disease and may be a useful screening procedure to select patients for further investigation, particularly those with evidence of life-threatening severe left coronary artery disease. (author)

  11. Comparison of cryopreservation bags for hematopoietic progenitor cells using a WBC-enriched product.

    Science.gov (United States)

    Dijkstra-Tiekstra, Margriet J; Hazelaar, Sandra; Gkoumassi, Effimia; Weggemans, Margienus; de Wildt-Eggen, Janny

    2015-04-01

    Hematopoietic progenitor cells (HPC) are stored in cryopreservation bags that are resistant to liquid nitrogen. Since Cryocyte bags of Baxter (B-bags) are no longer available, an alternative bag was sought. Also, the influence of freezing volume was studied. Miltenyi Biotec (MB)- and MacoPharma (MP)-bags passed the integrity tests without failure. Comparing MB- and MP-bags with B-bags, no difference in WBC recovery or viability was found when using a WBC-enriched product as a "dummy" HPC product. Further, a freezing volume of 30 mL resulted in better WBC recovery and viability than 60 mL. Additonal studies using real HPC might be necessary. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Two-stage nonlinear filter for processing of scintigrams

    International Nuclear Information System (INIS)

    Pistor, P.; Hoener, J.; Walch, G.

    1973-01-01

    Linear filters which have been successfully used to process scintigrams can be modified in a meaningful manner by a preceding non-linear point operator, the Anscombe-transform. The advantages are: The scintigraphic noise becomes quasi-stationary and thus independent of the image. By these means the noise can be readily allowed for in the design of the convolutional operators. Transformed images with a stationary signal-to-noise ratio and a non-constant background t correspond to untransformed images with a signal-to-noise ratio that varies in certain limits. The filter chain automatically adapts to these changes. Our filter has the advantage over the majority of space-varying filters of being realizable by Fast Fourier Transform techniques. These advantages have to be paid for by reduced signal amplitude to background ratios. If the background is known, this shortcoming can be easily by-passed by processing trendfree scintigrams. If not, the filter chain should be completed by a third operator which reverses the Anscombe-transform. The Anscombe-transform influences the signal-to-noise ratio of cold spots and of hot spots in a different way. It remains an open question if this fact can be utilized to directly influence the detectability of the different kinds of spots

  13. An independent evaluation of a new method for automated interpretation of lung scintigrams using artificial neural networks

    International Nuclear Information System (INIS)

    Holst, H.; Jaerund, A.; Evander, E.; Taegil, K.; Edenbrandt, L.; Maare, K.; Aastroem, K.; Ohlsson, M.

    2001-01-01

    The purpose of this study was to evaluate a new automated method for the interpretation of lung perfusion scintigrams using patients from a hospital other than that where the method was developed, and then to compare the performance of the technique against that of experienced physicians. A total of 1,087 scintigrams from patients with suspected pulmonary embolism comprised the training group. The test group consisted of scintigrams from 140 patients collected in a hospital different to that from which the training group had been drawn. An artificial neural network was trained using 18 automatically obtained features from each set of perfusion scintigrams. The image processing techniques included alignment to templates, construction of quotient images based on the perfusion/template images, and finally calculation of features describing segmental perfusion defects in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. The performance of the neural network was compared with that of three experienced physicians who read the same test scintigrams according to the modified PIOPED criteria using, in addition to perfusion images, ventilation images when available and chest radiographs for all patients. Performances were measured as area under the receiver operating characteristic curve. The performance of the neural network evaluated in the test group was 0.88 (95% confidence limits 0.81-0.94). The performance of the three experienced experts was in the range 0.87-0.93 when using the perfusion images, chest radiographs and ventilation images when available. Perfusion scintigrams can be interpreted regarding the diagnosis of pulmonary embolism by the use of an automated method also in a hospital other than that where it was developed. The performance of this method is similar to that of experienced physicians even though the physicians, in addition to perfusion images, also had access to ventilation images for

  14. Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop

    Energy Technology Data Exchange (ETDEWEB)

    Tedjasari, R S; Lubis, E [Radioactive-Waste Management Technology Centre, National Atomic Energy Agency of Indonesia(Indonesia)

    1996-07-01

    Thyroid dose estimation at Radioisotope Production Centre workers using WBC and calculation based on I-131 concentration in working area has been done. The aim of this research is to get the relation between WBC result and calculation using I-131 concentration in working area. The result indicates differences in a range of 3,2% to 53,2%. These differences caused of parameters which influence the calculation are not accurate. These results also indicate that dose estimation using WBC is relatively batter and more accurate but need to have certain information about time of intake.

  15. Evaluation of the regional lung function revealed in radioaerosol scintigram of chronic obstructive pulmonary disease, 1. The comparison of radioaerosol scintigram with the lung function tests in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, T [Kyoto Univ. (Japan). Faculty of Medicine

    1980-02-01

    We classified the findings of radioaerosol inhalation scintigrams of patients with various stages of obstructive pulmonary disease (COPD) into 4 grades, according to the extent of peripheral irregularity and central hot spot formation; Stage I represents normal homogeneous distribution, stage II represents peripheral irregularity, stage III represents additional hot spot formation and stage IV represents further regional defect. This aerosol grading criteria was then compared with routine and specific lung function tests. The aerosol grading criterion correlated well with FEV sub(1.0)% which is a good indicator of the severity of COPD. The central hot spot formation correlated well with FEV sub(1.0)% and respiratory resistance (R.p.) determined by the oscillation method, both of which are good indicators of abnormality in central airway resistance. Peripheral irregularity correlated well with: 1) flows at 50%VC and 25%VC in a maximum forced expiratory flow volume curve; 2) closing volume (CV/VC%); 3) delta N/sub 2/%/l in N/sub 2/ single washout test; and 4) the regional delay of /sup 133/Xe washout process, all of which are sensitive indicators of small airway disease. It is therefore reasonable to conclude that the radioaerosol scintigram reveals the regional lung function both in terms of airway resistance (R) and compliance (C). This criterion was useful in quantitatively evaluating the regional ventilation distribution of COPD and the therapeutic effect on bronchial asthma. The mechanism of aerosol particle deposition related to characteristic central hot spot formation accompanied with peripheral irregularity in a radioaerosol scintigram of COPD, needs further exploration concerning the aerodynamic behavior of aerosol particles in the airways both during inspiration and expiration.

  16. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  17. Increased incidence and clinical correlation of persistently abnormal technetium pyrophosphate myocardial scintigrams following acute myocardial infarction in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Nicod, P.; Lewis, S.E.; Corbett, J.C.; Buja, L.M.; Henderson, G.; Raskin, P.; Rude, R.E.; Willerson, J.T.

    1982-01-01

    Persistently abnormal /sup 99m/Tc stannous pyrophosphate myocardial scintigrams (PPi+) appear to be associated with a relatively poor prognosis after acute myocardial infarction (AMI). To assess the incidence and implications of PPi+, we performed a retrospective analysis in 29 patients with and 25 patients without diabetes mellitus who had abnormal myocardial scintigrams within 4 days of AMI and who had follow-up scintigrams at least 3 months after hospital discharge. There were no significant differences between patients with and without diabetes as regards age, incidence of transmural or nontransmural AMI, or degree of left ventricular dysfunction after AMI. Persistently abnormal PPi+ occurred more commonly in patients with diabetes than in nondiabetic patients (18 of 29, 62%, compared to 3 of 25, 12%; p less than 0.001). Patients with chronic PPi+ had more frequent cardiac complications following hospital discharge (p less than 0.005) including death, recurrent AMI, unstable angina, and intractable congestive heart failure. Postmortem analysis in two patients with diabetes and chronic PPi+ revealed marked myocytolysis. Thus, patients with diabetes mellitus have an increased incidence of post-AMI persistently abnormal technetium (PPi+) scintigrams and relatively poor prognosis following myocardial infarction

  18. Effect of latrogenic trauma on the bone scintigram: an animal study. Concise communication

    International Nuclear Information System (INIS)

    Alazraki, N.; Moitoza, J.; Heaphy, J.; Taylor, A. Jr.

    1984-01-01

    An animal study was performed to assess the effect on the Tc-99m phosphate bone scintigram of injury by needle aspiration or drill hole to metaphyseal and diaphyseal areas in immature and mature bones. Results showed that in 12 immature rabbits such trauma to metaphyseal regions had no effect on the bone image. Similar metaphyseal trauma in two mature dogs showed definite abnormalities on the bone image, but in one mature rabbit, no abnormality could be identified by scintigram. Diaphyseal trauma always gave a definitely abnormal bone image. Extrapolation of these results to humans should be cautious, but it suggests that needling or drilling in metaphyseal regions in neonates or young children probably does not affect later bone images

  19. Evaluation of the prognosis of cancer patients with metastatic bone tumors based on serial bone scintigrams

    International Nuclear Information System (INIS)

    Ohmori, Kazuo; Matsui, Hisao; Yasuda, Taketoshi; Kanamori, Masahiko; Yudoh, Kazuo; Seto, Hikaru; Tsuji, Haruo

    1997-01-01

    We counted the lesions at the time of detection of bone metastases and calculated the rate of increase in the number of bone metastases from changes in serial bone scintigrams, and investigated the usefulness of serial scintigrams as a prognostic indicator in patients with metastatic bone tumors. Subjects were 112 patients with bone metastases from four types of primary lesion: 21 with prostate cancer, 27 breast cancer, 39 lung cancer and 25 stomach cancer. Of these, 18 (prostate), 19 (breast), nine (lung) and eight (stomach) underwent serial bone scintigrams in which bone metastases were first detected and identified as progressing. The numbers of lesions at the time of detection of bone metastases for prostate and stomach cancers were significantly greater than those for lung cancer. The rate of increase in the number of bone metastases for stomach cancer was significantly higher than that for prostate or breast cancers. There was no correlation between the survival time after the detection of bone metastases and the number of lesions at the time of detection in the four types of cancer. However, in prostate cancer, a negative correlation existed between the survival time after the detection of bone metastases and the rate of increase in the number of bone metastases. Thus, in patients with bone metastases from prostate cancer, it appears that the rate of increase in the number of bone metastases, estimated from serial bone scintigrams, was indicative of prognosis. (author)

  20. Correlation of the perfusion scintigram with pulmonary functions in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Kou; Ashitaka, Tsuyoshi; Uchibori, Shigeyasu [Toho Univ., Tokyo (Japan). School of Medicine; Takano, Masaaki

    1992-11-01

    The authors carried out ventilation-perfusion scintigraphy and pulmonary function tests in 21 patients with chronic obstructive pulmonary disease. It was used [sup 99m]Tc-macroaggregate for perfusion scintigram and [sup 133]Xe gas for ventilation scintigram. It was added the radioactivities of rebreathing phase and made lung volume image using a computer. Regions of interest (ROIs) were derived from radioactivities in each image. ROIs on lung volume image included each whole lung and those on perfusion image included the areas which had relatively high radioactivity. The authors counted the area of ROIs on lung volume (L) and perfusion (P) images. Then it was used the ratio of perfusion to lung volume (P/L) as a parameter of pulmonary perfusion. P/L had the significant correlations with the vital capacity, the actual FFV[sub 1.0], arterial oxygen partial pressure, diffusing capacity, RV/TLC and peak flow rate. These results suggested that P/L was a useful parameter of pulmonary perfusion in chronic obstructive pulmonary disease. (author).

  1. Indium labelled bleomycin (111In-BLM) as a tumor localizing agent

    International Nuclear Information System (INIS)

    Akisada, Masayoshi; Hayashi, Sanshin.

    1976-01-01

    Both fundamental and clinical studies of 111 In-BLM were performed. The in vivo stability of the complex was ascertained by thin-layer-chromatography of urine. The blood clearance, ratio of 111 In-BLM in plasma to that in whole blood, and cumulative excretion curves of urine and stool were studied. The blood clearance curve showed that the first half time was 16 minutes and that more than 90% of the administered activity was cleared from the circulating blood in two days. Ratios of plasma activity to the whole blood was almost constant 100 hours after injection. Urinary and fecal excretion showed that 80% of the administered activity was excreted in 24 hours, mainly in the urine (less than 1.0% in the feces). There appeared to be an inverse relationship between urinary and fecal excretion. The effective and biological half time of the liver, heart, bone marrow at the level of L 4 and spleen were obtained by counting the activity externally using probes located at each corresponding site. The activity in the bone marrow and heart had a rather short effective half time. The clinical usefulness of 111 In-BLM as a tumor imaging agent was evaluated in 19 patients, with 12 malignant and 7 benign lesions in Mitsui Memorial Hospital. Each study with 111 In-BLM was combined with 67 Ga-citrate scintigrams. A new method for comparative analyses of two radiopharmaceuticals without using a computer is reported here since comparative evaluation by the naked eye was difficult to make. Clinical experience to date seems to be encouraging to the detection of malignancy, although some benign tumors showed marked uptake of 111 In-BLM. (Evans, J.)

  2. A methodology to develop computational phantoms with adjustable posture for WBC calibration

    International Nuclear Information System (INIS)

    Fonseca, T C Ferreira; Vanhavere, F; Bogaerts, R; Hunt, John

    2014-01-01

    A Whole Body Counter (WBC) is a facility to routinely assess the internal contamination of exposed workers, especially in the case of radiation release accidents. The calibration of the counting device is usually done by using anthropomorphic physical phantoms representing the human body. Due to such a challenge of constructing representative physical phantoms a virtual calibration has been introduced. The use of computational phantoms and the Monte Carlo method to simulate radiation transport have been demonstrated to be a worthy alternative. In this study we introduce a methodology developed for the creation of realistic computational voxel phantoms with adjustable posture for WBC calibration. The methodology makes use of different software packages to enable the creation and modification of computational voxel phantoms. This allows voxel phantoms to be developed on demand for the calibration of different WBC configurations. This in turn helps to study the major source of uncertainty associated with the in vivo measurement routine which is the difference between the calibration phantoms and the real persons being counted. The use of realistic computational phantoms also helps the optimization of the counting measurement. Open source codes such as MakeHuman and Blender software packages have been used for the creation and modelling of 3D humanoid characters based on polygonal mesh surfaces. Also, a home-made software was developed whose goal is to convert the binary 3D voxel grid into a MCNPX input file. This paper summarizes the development of a library of phantoms of the human body that uses two basic phantoms called MaMP and FeMP (Male and Female Mesh Phantoms) to create a set of male and female phantoms that vary both in height and in weight. Two sets of MaMP and FeMP phantoms were developed and used for efficiency calibration of two different WBC set-ups: the Doel NPP WBC laboratory and AGM laboratory of SCK-CEN in Mol, Belgium. (paper)

  3. A methodology to develop computational phantoms with adjustable posture for WBC calibration

    Science.gov (United States)

    Ferreira Fonseca, T. C.; Bogaerts, R.; Hunt, John; Vanhavere, F.

    2014-11-01

    A Whole Body Counter (WBC) is a facility to routinely assess the internal contamination of exposed workers, especially in the case of radiation release accidents. The calibration of the counting device is usually done by using anthropomorphic physical phantoms representing the human body. Due to such a challenge of constructing representative physical phantoms a virtual calibration has been introduced. The use of computational phantoms and the Monte Carlo method to simulate radiation transport have been demonstrated to be a worthy alternative. In this study we introduce a methodology developed for the creation of realistic computational voxel phantoms with adjustable posture for WBC calibration. The methodology makes use of different software packages to enable the creation and modification of computational voxel phantoms. This allows voxel phantoms to be developed on demand for the calibration of different WBC configurations. This in turn helps to study the major source of uncertainty associated with the in vivo measurement routine which is the difference between the calibration phantoms and the real persons being counted. The use of realistic computational phantoms also helps the optimization of the counting measurement. Open source codes such as MakeHuman and Blender software packages have been used for the creation and modelling of 3D humanoid characters based on polygonal mesh surfaces. Also, a home-made software was developed whose goal is to convert the binary 3D voxel grid into a MCNPX input file. This paper summarizes the development of a library of phantoms of the human body that uses two basic phantoms called MaMP and FeMP (Male and Female Mesh Phantoms) to create a set of male and female phantoms that vary both in height and in weight. Two sets of MaMP and FeMP phantoms were developed and used for efficiency calibration of two different WBC set-ups: the Doel NPP WBC laboratory and AGM laboratory of SCK-CEN in Mol, Belgium.

  4. Computer-enhanced thallium scintigrams in asymptomatic men with abnormal exercise tests

    International Nuclear Information System (INIS)

    Uhl, G.S.; Kay, T.N.; Hickman, J.R. Jr.

    1981-01-01

    The use of treadmill testing in asymptomatic patients and those with an atypical chest pain syndrome is increasing, yet the proportion of false positive stress electrocardiograms increases as the prevalence of disease decreases. To determine the diagnostic accuracy of computer-enhanced thallium perfusion scintigraphy in this subgroup of patients, multigated thallium scans were obtained after peak exercise and 3 or 4 hours after exercise and the raw images enhanced by a computer before interpretations were made. The patient group consisted of 191 asymptomatic U.S. Air force aircrewmen who had an abnormal exercise electrocardiogram. Of these, 135 had normal coronary angiographic findings, 15 had subcritical coronary stenosis (less than 50 percent diameter narrowing) and 41 had significant coronary artery disease. Use of computer enhancement resulted in only four false positive and two false negative scintigrams. The small subgroup with subcritical coronary disease had equivocal results on thallium scintigraphy, 10 men having abnormal scans and 5 showing no defects. The clinical significance of such subcritical disease in unclear, but it can be detected with thallium scintigraphy. Thallium scintigrams that have been enhanced by readily available computer techniques are an accurate diagnostic tool even in asymptomatic patients with an easily interpretable abnormal maximal stress electrocardiogram. Thallium scans can be effectively used in counseling asymptomatic patients on the likelihood of their having coronary artery disease

  5. Reevaluation of lung perfusion scintigrams with 99mTc-macroaggregated albumin (Tc-MAA) as a tool of diagnostic procedures of chronic pulmonary emphysema

    International Nuclear Information System (INIS)

    Kitahara, Yoshinari; Maruyama, Masao; Takamoto, Masahiro; Tanaka, Yasushi; Harada, Susumu; Harada, Yasuko; Ishibashi, Tsuneo; Shinoda, Atsushi

    1991-01-01

    We performed scintiscanning with Tc-MAA lung perfusion in thirty cases of chronic pulmonary emphysema (CPE) and thirty cases of bronchial asthma. In the former group, all of the cases showed the definite emphysematous changes on computed tomography (CT). It seemed that the whole impression to scintigram could diagnose CPE almost correctly. As the most important abnormality in scintigrams of CPE was their filling defects, we examined the characteristics of the defect-lesions. The results were as follows: firstly, the main lesions extended to the lobar to half-lobar size; secondly, defects were multiple in general; and thirdly, the distribution of defects was diffuse. Whereas the lesion in the scintigram is nonspecific for diagnosis of CPE in contrast to CT, we conclude that perfusion scintigram is valuable to evaluate the severity of CPE. (author)

  6. Correlation with liver scintigram, reticuloendothelial function test, plasma endotoxin level and liver function tests in chronic liver diseases. Multivariate analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ohmoto, Kenji; Yamamoto, Shinichi; Ideguchi, Seiji and others

    1989-02-01

    Liver scintigrams with Tc-99m phytate were reviewed in a total of 64 consecutive patients, comprising 28 with chronic hepatitis and 36 with liver cirrhosis. Reticuloendothelial (RES) function, plasma endotoxin (Et) levels and findings of general liver function tests were used as reference parameters to determine the diagnostic ability of liver scintigraphy. Multivariate analyses revealed that liver scintigrams had a strong correlation with RES function and Et levels in terms of morphology of the liver and hepatic and bone marrow Tc-99m uptake. General liver function tests revealed gamma globulin to be correlated with hepatic uptake and the degree of splenogemaly on liver scintigrams; and ICG levels at 15 min to be correlated with bone marrow and splenic uptake. Accuracy of liver scintigraphy was 73% for chronic hepatitis, which was inferior to general liver function tests (83%). When both modalities were combined, diangostic accuracy increased to 95%. Liver scintigraphy seems to be useful as a complementary approach. (Namekawa, K).

  7. Monitoring of a new approach of immunotherapy with allogenic 111In-labelled NK cells in patients with renal cell carcinoma

    International Nuclear Information System (INIS)

    Meller, Birgit; Lauer, Isabel; Schelper, Lutz F.; Hof, Katharina von; Richter, Eckart; Baehre, Manfred; Frohn, Christoph; Brand, Joerg-Matthias; Kirchner, Holger

    2004-01-01

    The transfusion of allogenic, in vitro expanded natural killer cells (NKC) is a novel therapy option in oncology. To date, however, the biodistribution and kinetics of allogenic NKC have not been investigated. Therefore, in this study three patients with renal cell carcinoma received 3-7 x 10 8 NKC labelled with indium-111 oxine with a tenfold excess of unlabelled cells during NKC therapy. Whole-body scintigrams were obtained (0.5-144 h) in the anterior and posterior views. Scintigrams were analysed using a region of interest technique, and single-photon emission tomography (SPET) studies of the abdomen were performed. Results were compared to those obtained with polymerase chain reaction (PCR) of the peripheral blood (determination of foreign DNA, nested PCR, limit of detection 0.01%). Shortly after transfusion of NKC, more than 50% of the activity was accumulated in the lungs. We observed redistribution effects from lungs to liver, spleen and bone marrow. No significant loss of activity could be detected. In two of four large metastases, tracer accumulation could be proven by SPET. As confirmed by scintigrams and PCR, the fraction of circulating transfused cells was low at all times. Long-term activity retention might be caused either by survival of the allogenic cells, as confirmed by PCR (up to 3 days p.i.), or by phagocytosis of labelled cellular fragments. However, PCR data and uptake in metastases indicated long survival of a portion of allogenic NKC. Such long survival and low retention of the cells in the lung are requirements for an effective immunotherapeutic approach. (orig.)

  8. Bone metastases from gastric cancer. Clinical evaluation on bone scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Seto, Mikito; Tonami, Norihisa; Koizumi, Kiyoshi; Sui, Osamu; Hisada, Kinichi [Kanazawa Univ. (Japan). School of Medicine

    1983-07-01

    We have studied bone scintigrams in 60 patients with gastric cancer. Of these 60 patients, bone metastases were found in 15 patients (25 %). There were no evidence of bone metastases in polypoid lesions, cancers of the antrum, carcinomas in situ, advanced cancers without invasion to serosa, cancer with N/sub 0/ or N/sub 1/ regional lymph node metastases, highly differentiated adenocarcinomas and papillary adenocarcinomas. On the contrary, high rates of bone metastases were seen in cancers of the corpus, advanced cancers with invasion to neighbouring structures and tubular adenocarcinomas. Of these 15 patients with bone metastasis, 3 patients showed very similar clinical features and the findings of ''diffuse bone metastases on bone scintigrams.'' Cancer of the antrum showed high rates of liver metastases, while cancers of the corpus showed high rates of bone metastases. Sixty percent of the patients with bone metastases did not have liver metastases and there seemed to be no significant relationship between liver metastases and bone metastases. From these results we suppose that non-portal tract through the vertebral venous plexus instead of portal tract may be the other route of bone metastases from gastric cancer.

  9. Fever of unknown origin: prospective comparison of diagnostic value of 18F-FDG PET and 111In-granulocyte scintigraphy

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette; Eigtved, Annika

    2004-01-01

    The diagnostic work-up in patients with fever of unknown origin (FUO) is often challenging and frequently includes nuclear medicine procedures. Whereas a role for leucocyte or granulocyte scintigraphy in FUO is generally accepted, a possible role of fluorine-18 fluorodeoxyglucose (FDG) positron...... emission tomography (PET) in these patients remains to be established. To study this, we compared prospectively, on a head-to-head basis, the diagnostic value of FDG-PET and indium-111 granulocyte scintigraphy in patients with FUO. Nineteen patients with FUO underwent both FDG-PET and (111)In......-granulocyte scintigraphy within 1 week. FDG-PET scans and granulocyte scintigrams were reviewed by different doctors who were blinded to the result of the other investigation. The diagnostic values of FDG-PET and granulocyte scintigraphy were evaluated with regard to identification of a focal infectious...

  10. Monitoring of a new approach of immunotherapy with allogenic {sup 111}In-labelled NK cells in patients with renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Meller, Birgit; Lauer, Isabel; Schelper, Lutz F.; Hof, Katharina von; Richter, Eckart; Baehre, Manfred [Clinic of Radiotherapy and Nuclear Medicine, University of Luebeck, Ratzeburger Allee 160, 23538, Luebeck (Germany); Frohn, Christoph; Brand, Joerg-Matthias; Kirchner, Holger [Institute of Immunology and Transfusion Medicine, University of Luebeck, Ratzeburger Allee 160, 23538, Luebeck (Germany)

    2004-03-01

    The transfusion of allogenic, in vitro expanded natural killer cells (NKC) is a novel therapy option in oncology. To date, however, the biodistribution and kinetics of allogenic NKC have not been investigated. Therefore, in this study three patients with renal cell carcinoma received 3-7 x 10{sup 8} NKC labelled with indium-111 oxine with a tenfold excess of unlabelled cells during NKC therapy. Whole-body scintigrams were obtained (0.5-144 h) in the anterior and posterior views. Scintigrams were analysed using a region of interest technique, and single-photon emission tomography (SPET) studies of the abdomen were performed. Results were compared to those obtained with polymerase chain reaction (PCR) of the peripheral blood (determination of foreign DNA, nested PCR, limit of detection 0.01%). Shortly after transfusion of NKC, more than 50% of the activity was accumulated in the lungs. We observed redistribution effects from lungs to liver, spleen and bone marrow. No significant loss of activity could be detected. In two of four large metastases, tracer accumulation could be proven by SPET. As confirmed by scintigrams and PCR, the fraction of circulating transfused cells was low at all times. Long-term activity retention might be caused either by survival of the allogenic cells, as confirmed by PCR (up to 3 days p.i.), or by phagocytosis of labelled cellular fragments. However, PCR data and uptake in metastases indicated long survival of a portion of allogenic NKC. Such long survival and low retention of the cells in the lung are requirements for an effective immunotherapeutic approach. (orig.)

  11. Fundamental and clinical studies on simultaneous, quantitative analysis of hepatobiliary and gastrointestinal scintigrams using double isotope method

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, Y; Kakihara, M; Sasaki, M; Tabuse, Y; Takei, N [Wakayama Medical Coll. (Japan)

    1981-04-01

    Double isotope method was applied to carry out simultaneous and quantitative analysis of hepatobiliary and gastrointestinal scintigrams. A scinticamera with parallel collimator for medium energy was connected to a computer to distinguish the two isotopes at a time. 4mCi of sup(99m)Tc-(Sn)-pyridoxylideneisoleucine (Tc-PI) and 200 ..mu..Ci of /sup 111/In-diethylenetriaminepentaacetic acid (In-DTPA) were administrated by i.v. injection and per oral, respectively. Three normal (two women and a man) and 16 patients after the operation of gastric cancer (10 recovered by Roux-en Y method after the total gastrectomy, and 6 recovered after the operation replacing the jejunum between the esophagus and duodenum) were investigated. The process of bile secretion and its mixing with food were followed by the scanning quantitatively. The analysis of time-activity variation at each organ indicated that the replacing operation gave more physiological recovery than that by Roux-en Y method. This method is noninvasive to patients and is promising to follow the process or activity of digestion in any digestive organ after surgery.

  12. Standardization and awtomatic plotting of zones of interest in processing scintigrams of a head and neck

    International Nuclear Information System (INIS)

    Ivanov, Yu.N.; Prikhod'ko, A.G.; Chelyshev, M.M.

    1982-01-01

    A method for determining quantitative indeces of the level of accumulation and localization of lesion centers in scintigrams of head and neck by means of automatic plotting of standardized zones of interest, using the PDP-11/34 computer, is suggested. A supposition that for anatomic regions of head and neck, which are of interest for an investigator, relatively constant forms and inconsiderable variability of sizes are characteristic lies in the basis of the method suggested. Under such conditions the task of standardization and automatic plotting of zones of interest is reduced to determination of anatomic region boundaries relatively reference points selected. On the basis of analysis of archives data 26 zones of interest have been selected. Names of the zones and their abbreviations are presented. A conclusion is made that the suggested method of scintigram processing permits to increase the accuracy of localization determination of pathological centers. At that, the objectivity of diagnostic solution increases and reproducibility and comparability of different investigation results are ensured

  13. Evaluation of the regional lung function revealed in radioaerosol scintigram of chronic obstructive pulmonary disease, 1

    International Nuclear Information System (INIS)

    Suzuki, Teruyasu

    1980-01-01

    We classified the findings of radioaerosol inhalation scintigrams of patients with various stages of obstructive pulmonary disease (COPD) into 4 grades, according to the extent of peripheral irregularity and central hot spot formation; Stage I represents normal homogeneous distribution, stage II represents peripheral irregularity, stage III represents additional hot spot formation and stage IV represents further regional defect. This aerosol grading criteria was then compared with routine and specific lung function tests. The aerosol grading criterion correlated well with FEV sub(1.0)% which is a good indicator of the severity of COPD. The central hot spot formation correlated well with FEV sub(1.0)% and respiratory resistance (R.p.) determined by the oscillation method, both of which are good indicators of abnormality in central airway resistance. Peripheral irregularity correlated well with: 1) flows at 50%VC and 25%VC in a maximum forced expiratory flow volume curve; 2) closing volume (CV/VC%); 3) delta N 2 %/l in N 2 single washout test; and 4) the regional delay of 133 Xe washout process, all of which are sensitive indicators of small airway disease. It is therefore reasonable to conclude that the radioaerosol scintigram reveals the regional lung function both in terms of airway resistance (R) and compliance (C). This criterion was useful in quantitatively evaluating the regional ventilation distribution of COPD and the therapeutic effect on bronchial asthma. The mechanism of aerosol praticle deposition related to characteristic central hot spot formation accompanied with peripheral irregularity in a radioaerosol scintigram of COPD, needs further exploration concerning the aerodynamic behavior of aerosol particles in the airways both during inspiration and expiration. (author)

  14. Role of renal function and calcemia in demonstration of kidneys in sup(99m)Tc-diphosphonate skeletal scintigrams

    International Nuclear Information System (INIS)

    Marincek, B.; Flury, W.; Roesler, H.; Bern Univ.

    1977-01-01

    Normally, in sup(99m)Tc-diphosphonate skeletal scintigrams the kidneys are delineated with the same intensity as the lumbar spine. This is not the case in patients with reduced renal function. In a series of 20 patients with varying degrees of renal insufficiency, a continuous decrease in the renal intensity with increasing serum creatinine was seen: clearly recognizable decreased renal intensity in patients with serum creatinine over 2 mg% and no visualization of the kidneys in patients with serum creatinine over 8 mg%. This effect is intensified through a simultaneously existing hypocalcemia, while a hypercalcemia has the opposite effect; i.e. the intensity decrease is partially prevented. In patients with normal renal function a hypercalcemia even leads to an increased renal intensity. As a further cause for excessive renal intensity, an increased parenchymal transit time was found in the radionephrography in 5 out of 11 patients with normal serum creatinine in whom the increased renal intensity in the skeletal scintigram was a chance finding. (orig.) [de

  15. Notes on the liver correction applied systematically to all renal scintigrams

    International Nuclear Information System (INIS)

    Artus, J.C.; Miro, L.; Durand, J.

    1976-01-01

    A problem still outstanding in renal scintigraphy is analyzed: how to deal with the parasitic tracer uptake by the liver. Some investigators correct systematically for the liver shadow by injecting technetium labelled colloids, for others the data supplied by 197 HgCl 2 scintigraphy alone allow to estimate the kidney uptake. Objective criteria are given as a mean to decide whether a liver scintigram is necessary in order to obtain the kidney uptake rate [fr

  16. Studies on the clinical usefulness of the 111indium chloride bone marrow scintigraphy in patients with aplastic anemia

    International Nuclear Information System (INIS)

    Ino, Teruo; Ito, Naoya; Takeda, Nobuhide

    1985-01-01

    111 Indium chloride ( 111 In-Cl 3 ) appears to be a radionuclide appropriate for a bone marrow scanning because of its physical and chemical characteristics; it is, like iron, bound to and transported by transferrin and it has a photopeak suitable for scintigraphy. This study was undertaken to assess the bone marrow function by 111 In-Cl 3 bone marrow scintigraphy in patients with asplastic anemia. Bone marrow scintigraphy was performed in 21 patients with aplastic anemia with varying degrees of severity including 15 who had no previous treatments. The scintigrams were taken 48 hours after intravenous injection of 111 MBq(3 mCi) of 111 In-Cl 3 . All of them showed various degrees of reduction in uptake of 111 In-Cl 3 by the marrow. The abnormal scan grade was classified into 3 types: Type I, non-accumulation (5); Type II, low-accumulation (15); Type III, uneven accumulation (1). In type III, degree of radioisotope accumulation between the sternum and the ilium was different, and this difference correlated with that of bone marrow cellularity. In 2 patients of type II, hematological improvement occurred after treatment, which was also accompanied by simultaneous increase of 111 In-Cl 3 uptake by the marrow. These findings suggested that the degree of radioisotope accumulation in the marrow reflects that of bone marrow cellularity. Type I patients were clinically severe and poor in prognosis as compared to type II and type III patients; four out of 5 died within 2 months. Bone marrow transplantation may be the treatment of choice in type I patients when feasible. (author)

  17. Use of 111In-labeled autologous leukocytes to image an abdominal abscess in a horse

    International Nuclear Information System (INIS)

    Koblik, P.D.; Lofstedt, J.; Jakowski, R.M.; Johnson, K.L.

    1985-01-01

    Indium 111-labeled autologous leukocytes were used to image an abdominal abscess in a horse with a palpable abdominal mass and history of Streptococcus equi infection. A focal area of radioactivity was identified in the location corresponding to the abscess. Imaging of this focal uptake was optimal 48 hours after injection. Similar scans obtained in 2 clinically normal horses revealed no evidence of focal radioactivity in this region. The cell labeling procedure gave acceptable labeling efficiency (87.5%) but an excessive number of damaged WBC, resulting in persistent lung radioactivity on all images. No adverse effects were noted. Radiation measured in the horse and its excreta were well within acceptable limits

  18. Preoperative clinical radioimmunodetection of pancreatic cancer by 111In-labeled chimeric monoclonal antibody Nd2

    International Nuclear Information System (INIS)

    Sawada, Tetsuji; Nishihara, Tamahiro; Yamamoto, Atsushi

    1999-01-01

    The present study was carried out with the purpose of evaluating the clinical usefulness of radioimmunodetection (RAID) with 111 In-labeled murine/human chimeric monoclonal antibody, Nd2 (c-Nd2) in patients with pancreatic cancer. Nineteen patients suspected to have pancreatic cancer were administered intravenously 74 MBq/2 mg 111 In-labeled c-Nd2 in 100 ml of saline containing 2% albumin over 30 min. A scintigram was obtained on the 3rd day after infusion by using single photon emission computed tomography (SPECT) imaging. Of the 14 patients finally diagnosed as having pancreatic cancer on the basis of surgical specimens or progress of disease, specific focal uptake at the site of the tumor was detected in 12 (true positive cases), representing a sensitivity of 85.7% (12/14), and liver metastasis was found in one case with metastasis. Of the 5 patients diagnosed with tumor-forming pancreatitis (TFP), 4 patients demonstrated true negative imaging, but one patient whose tumor demonstrated interesting findings in histology and immunostaining, showed false positive imaging. Of patients investigated for human anti-chimeric antibody (HACA) response, none showed HACA response, and no allergic reaction was seen in any of the patients administered c-Nd2. These results suggest that RAID with 111 In-labeled c-Nd2 is useful for differential preoperative diagnosis between invasive pancreatic cancer and TFP. (author)

  19. Safety of growth factor administration for leukapheresis in those with WBC counts greater than 60,000/µl.

    Science.gov (United States)

    Chen, Weihong; Rizzieri, David; Drago, Susan

    2015-02-01

    Peripheral blood stem cell mobilization using growth factors is a common method of stem cell collection for transplantation, however, little is reported concerning safety of continued growth factor delivery in exceptional responders with very high white blood cell (WBC) counts in preparation for pheresis. We performed a retrospective study of the safety of growth factor delivery for leukapheresis in those with WBC counts greater than 60,000/µl. Allogeneic donors received 5 days of granulocyte colony-stimulating factor (G-CSF) at a daily dose of 10 or 16 µg/kg. Autologous donors received G-CSF 10 µg/kg/day +/- chemotherapy until peripheral blood CD34(+) count reached 10/µl. Granulocyte donors received 300 µg dose of G-CSF the day prior to donation. Out of 3,037 leukapheresis collections from 1998 to 2005, we identified 303 collections from 204 donors or patients who had a WBC > 60,000/µl. WBC counts were ≥100,000/µl in seven of these subjects. If inadequate stem cell dose was obtained with pheresis with WBC counts this high, patients had growth factor dosing decreased 50% but still received a dose till stem cell collection was completed. Of the 204 subjects, 122 were patients and 82 were donors. These 204 donors/patients had no serious adverse events reported other than the common reports of myalgia, bone pain, and headache associated with administration of growth factors. Pain levels ranged from mild to severe and usually were managed by over the counter analgesics. Continuing ½ the dose of neupogen to complete the pheresis process appears safe in subjects with very high white blood counts. © 2014 Wiley Periodicals, Inc.

  20. Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Lie, S.P.; Simoons, M.L.; Hoek, C.; Gerbrands, J.J.; Wijns, W.; Bakker, W.H.; Kooij, P.P.M.

    1983-01-01

    A fully automated procedure for the computation of left-ventricular ejection fraction (EF) from cardiac-gated Tc-99m blood-pool (GBP) scintigrams with fixed, dual, and variable ROI methods is described. By comparison with EF data from contrast ventriculography in 68 patients, the dual-ROI method (separate end-diastolic and end-systolic contours) was found to be the method of choice; processing time was 2 min. Success score of dual-ROI procedure was 92% as assessed from 100 GBP studies. Overall reproducibility of data acquisition and analysis was determined in 12 patients. Mean value and standard deviation of differences between repeat studies (average time interval 27 min) were 0.8% and 4.3% EF units, respectively, (r=0.98). The authors conclude that left-ventricular EF can be computed automatically from GBP scintigrams with minimal operator-interaction and good reproducibility; EFs are similar to those from contrast ventriculography

  1. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Plachcinska, A.; Kusmierek, J.; Mikolajczak, R.; Kozak, J.; Rzeszutek, K.

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99m Tc-depreotide (Neospect, Amersham) and 99m Tc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (±) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both diopharmaceuticals differed significantly. 99m Tc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99m Tc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology - lung cancer - was revealed (5 - adenocarcinoma, 1 - squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99m Tc-depreotide scintigrams were true negative, 1 - equivocal and 5 - false positive, whereas 6 99m Tc

  2. A study on an automated computerized differential diagnosis of diffuse liver diseases, based only on hepatic scintigrams using sup(99m)Tc-Sn-colloid

    International Nuclear Information System (INIS)

    Matsuo, Michimasa; Fujii, Susumu; Kaneda, Yukio

    1980-01-01

    Hepatic scintigrams using sup(99m)Tc-compounds are now routinely performed. In this study, automated computerized pattern characterizations of right lateral hepatic scintigrams using sup(99m)Tc-Sn colloid were studied to extract characteristic indicators, which are effective for an automated computerized differential diagnosis. The program, developed by us, of the automated computerized pattern characterization and the automated computerized differential diagnosis can be performed without the aid of professional doctors' ability of pattern recognition. The right lateral hepatic scintigrams of fifty one cases, which are accurately diagnosed by biopsy, are applied as the training group. The results of the automated computerized differential diagnosis were as follows: Three cases were accurately diagnosed among 3 normal cases; Three among 3 acute hepatitis; Seven among 7 chronic inactive hepatitis; Twenty among 22 chronic active hepatitis; Sixteen among 16 liver cirrhosis. Only two cases of chronic active hepatitis are falsely-diagnosed as chronic inactive hepatitis and as liver cirrhosis respectively. The over all accuracy rate was 96% in the training group. With this result, the automated computerized differential diagnosis of diffuse liver diseases is suggested to be possible, based on the hepatic scintigram. (author)

  3. Clinical evaluation of renal scintigram with 123I-OIH and sup(99m)Tc-DTPA in renal transplantation

    International Nuclear Information System (INIS)

    Ishibashi, Akira; Fujino, Awato; Ikeda, Shigeru; Ishii, Katsumi; Nakazawa, Keiji

    1983-01-01

    We have carried out 85 renal scintigrams on the 29 renal transplants last 6 months. Clinical usefulness of 123 I-IIH (ortho-iodohippurate) specially prepared compared with that of sup(99m)Tc-DTPA. The parameters of the vascular phase, perfusion index (PI) and (mean) transit time (TT), for the 123 I-OIH and sup(99m)Tc-DTPA renal scintigrams, were almost identical. Therefore it might be thought that renal circulation of 123 I-OIH is similar to that of sup(99m)Tc-DTPA. Moreover 123 I-OIH can afford us specific information on the exretory phase. The complicated renal transplants are well differentiated from normal functioning ones by B/K ratio of 123 I-OIH. B/K ratio is one of the parameters for the excretory phase. 123 I-OIH could be a useful agent for the clinical evaluation after renal transplantation. (author)

  4. In-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Hanano, Masaharu; Kimura, Michio; Ojima, Kenji [Niigata Univ. (Japan). School of Medicine

    1984-06-01

    /sup 111/In-labeled platelet scintigraphy was carried out in 20 patients suspected of thrombosis, to evaluate its efficacy for the detection of intracardiac and intravascular thrombi. Hemostatic studies including PT, aPTT, fibrinogen, FDP, platelet retention by Hellem II method, platelet aggregation induced by ADP (1 ..mu..M, 10 ..mu..M), collagen (2 ..mu..g/ml) and arachidonate (2 mM), and platelet survival were examined simultaneously. Two of these patients were also studied by fibrinogen scintigraphy labeled with sup(99m)Tc. The platelets obtained from the patients were labeled with /sup 111/In-oxine according to a method originated by Yui et al. In the platelet scintigram, positive findings were demonstrated in 9 cases : 2 left ventricular, 3 left atrial, and 4 vascular thrombi. These were in a good accordance to the findings obtained by at least one from angiography, echography and surgery. Platelet aggregation induced by 1 ..mu..M ADP was elevated in 4 of the 7 patients with positive findings and 3 of the 7 patients with negative findings. Shortened platelet survivals were observed in two of the 10 patients; dissecting aortic aneurysm and infective prosthetic valve endocarditis with hepatosplenomegaly. There was no significant difference in the platelet function and the platelet survival between the patients with positive and negative findings. It was difficult to detect thrombi by the fibrinogen scintigraphy labeled with sup(99m)Tc in the two patients studied. In conclusion, /sup 111/In-labeled platelet scintigraphy seems to be very useful to detect thrombi.

  5. Persistent renal cortical scintigram defects in children 2 years after urinary tract infection

    International Nuclear Information System (INIS)

    Ditchfield, Michael R.; Cook, David J.; Campo, John F. de; Grimwood, Keith; Powell, Harley R.; Gulati, Sanjeev; Sloane, Robert

    2004-01-01

    Background: Renal cortical scintigraphic studies challenge the role of vesicoureteric reflux in renal scar development, emphasizing instead the part played by acute pyelonephritis. Objective: To determine the prevalence of renal cortical defects in a child cohort 2 years after the child's first diagnosed urinary tract infection and to analyze the relationship of these defects with acute illness variables, primary vesicoureteric reflux and recurrent infections. Materials and methods: In a prospective cohort study, 193 children younger than 5 years with their first proven urinary tract infection underwent renal sonography, voiding cystourethrogram, and renal cortical scintigraphy within 15 days of diagnosis. Two years later, 150 of the 193 children, or 77.7%, had a further renal cortical scintigram, including 75, or 86.2%, of the 87 children who had acute scintigraphic defects. The relationship of cortical defects to age, gender, pre-treatment symptom duration, hospitalization, presence and grade of vesicoureteric reflux, and recurrent urinary tract infections was evaluated. Results: Overall, 20 of the 150 (13.3%; 95% confidence interval (CI) 8.3, 19.8) children had persistent defects 2 years after infection. This included 20 of 75 (26.7%; 95% CI 17.1, 38.1) with initially abnormal scintigrams. No new defects were detected. Although acute defects were more common in the young, those with persistent defects were older (median ages 16.4 vs. 6.8 months, P=0.004) than those with transient abnormalities. After adjustment for age, persistent defects were no longer associated with gender and were not predicted by acute illness variables, primary vesicoureteric reflux or recurrent infections. (orig.)

  6. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99mTc-depreotide (Neospect, Amersham) and 99mTc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (+/-) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both radiopharmaceuticals differed significantly. 99mTc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99mTc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology--lung cancer--was revealed (5--adenocarcinoma, 1--squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99mTc-depreotide scintigrams were true negative, 1--equivocal and 5--false positive, whereas 6 99m

  7. 111Indium-labeled neutrophil migration into the lungs of bleomycin-treated rabbits assessed noninvasively by external scintigraphy

    International Nuclear Information System (INIS)

    Haslett, C.; Shen, A.S.; Feldsien, D.C.; Allen, D.; Henson, P.M.; Cherniack, R.M.

    1989-01-01

    Factors controlling neutrophil migration into the lung are poorly understood, but their identification is important for our understanding of the pathogenesis of inflammatory lung diseases. Pulmonary inflammation is difficult to quantify, and neutrophils in tissues and BAL may not accurately represent cell migration. In this study, intravenously delivered pulses of rabbit neutrophils labeled with Indium-111 (111In-neutrophils) were used to monitor neutrophil migration into the lungs. Radioactivity quantified in the lung region of interest (ROI) of external gamma camera scintigrams recorded 24 h after intravenous 111In-neutrophil injection accurately reflected the actual neutrophil-associated lung tissue radioactivity. ROI radioactivity at 24 h also correlated closely with the percent of 111In-neutrophils that had migrated into lavageable air spaces, and this parameter therefore provided an index of total lung 111In-neutrophil migration. Using 24-h ROI radioactivity and percent of injected 111In-neutrophils recovered in BAL at 24 h as indices of neutrophil migration into the lung, it was found that intratracheal saline caused only a transient neutrophil migration, whereas 10 U/kg intratracheal bleomycin induced migration that persisted for as long as 3 wk. 111In-neutrophil migration into the lung, assessed by external scintigraphy, correlated with total neutrophils quantified in histologic sections (r = 0.71, p = 0.006). The data suggest that this approach will be valuable in investigating mechanisms controlling neutrophil migration in lung inflammation, and that 111In-neutrophil scintigraphy may provide a noninvasive index of total lung neutrophil load that might be useful in staging inflammation in patchy diseases such as idiopathic pulmonary fibrosis

  8. 99mTc-HMPAO WBC-scintigraphy: Are all positive findings in traumatology mandatory for surgical invention?

    International Nuclear Information System (INIS)

    Winker, K.H.; Weller, S.; Reuland, P.; Feine, U.

    1989-01-01

    In 5 case reports of traumatology patients the authors describe a subgroup of patients (IYON = infection yes, operation no) with positive WBC scan and proven infection, which do not need surgical intervention and can be treated by conservative means. (orig.) [de

  9. Semi-automated measurements of heart-to-mediastinum ratio on 123I-MIBG myocardial scintigrams by using image fusion method with chest X-ray images

    Science.gov (United States)

    Kawai, Ryosuke; Hara, Takeshi; Katafuchi, Tetsuro; Ishihara, Tadahiko; Zhou, Xiangrong; Muramatsu, Chisako; Abe, Yoshiteru; Fujita, Hiroshi

    2015-03-01

    MIBG (iodine-123-meta-iodobenzylguanidine) is a radioactive medicine that is used to help diagnose not only myocardial diseases but also Parkinson's diseases (PD) and dementia with Lewy Bodies (DLB). The difficulty of the segmentation around the myocardium often reduces the consistency of measurement results. One of the most common measurement methods is the ratio of the uptake values of the heart to mediastinum (H/M). This ratio will be a stable independent of the operators when the uptake value in the myocardium region is clearly higher than that in background, however, it will be unreliable indices when the myocardium region is unclear because of the low uptake values. This study aims to develop a new measurement method by using the image fusion of three modalities of MIBG scintigrams, 201-Tl scintigrams, and chest radiograms, to increase the reliability of the H/M measurement results. Our automated method consists of the following steps: (1) construct left ventricular (LV) map from 201-Tl myocardium image database, (2) determine heart region in chest radiograms, (3) determine mediastinum region in chest radiograms, (4) perform image fusion of chest radiograms and MIBG scintigrams, and 5) perform H/M measurements on MIBG scintigrams by using the locations of heart and mediastinum determined on the chest radiograms. We collected 165 cases with 201-Tl scintigrams and chest radiograms to construct the LV map. Another 65 cases with MIBG scintigrams and chest radiograms were also collected for the measurements. Four radiological technologists (RTs) manually measured the H/M in the MIBG images. We compared the four RTs' results with our computer outputs by using Pearson's correlation, the Bland-Altman method, and the equivalency test method. As a result, the correlations of the H/M between four the RTs and the computer were 0.85 to 0.88. We confirmed systematic errors between the four RTs and the computer as well as among the four RTs. The variation range of the H

  10. Relation of Serum Alkaline Phosphatase to liver scintigram in patients with hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, H; Harada, T; Nawata, J; Hayakawa, M; Nishioka, M; Takemoto, T; Yokoyama, T; Takahashi, M

    1982-12-01

    Serum Alkaline Phosphatase (ALP) was studied in relation to liver scintigrams of 54 patients with hepatocellular carcinoma. The ALP activity was higher with larger tumors and in multiple tumors. Within the single tumor group, the activity was higher when the tumor was located in the hilum than in the periphery. The incidence of ALP-1 isoenzyme (bile ALP) roughly paralleled the total ALP activity. These results suggest that the variation of serum ALP seen in each individual patients with hepatocellular carcinoma reflects the volume of cholestatic liver tissue, which is changed by the number, size and localization of the tumor nodules in the liver.

  11. Comparative Evaluation of C-Reactive Protein and WBC Count in Fascial Space Infections of Odontogenic Origin.

    Science.gov (United States)

    Bagul, Ravikiran; Chandan, Sanjay; Sane, Vikrant Dilip; Patil, Sujay; Yadav, Dinesh

    2017-06-01

    To assess efficacy of C-reactive protein levels as monitoring tools for patients with fascial space infections of odontogenic origin. A randomized prospective study was conducted on 20 patients suffering from fascial space infection of odontogenic origin, in the department of Oral and Maxillofacial Surgery Bharati Vidyapeeth dental college and hospital, Pune, Patients between 18 and 60 years of age of both the sexes were selected. All patients were treated and observed by the same surgeon. Patient's venous blood sample was collected pre-operatively and on 2nd and 5th post-operative days for evaluation of WBC count and C-reactive protein (CRP). All patients were encouraged for strict follow-up protocol. Where the results of WBC count and CRP when compared it was seen that the mean values of WBC were normal in 15 cases and abnormal in 5 cases on day 0, day 2 and day 5; whereas the mean values of CRP were abnormal on day 0 and day 2 and were within normal limit on day 5 in all cases. The findings of this prospective analysis indicate that White blood cells and C-reactive protein are effective markers for determining severity of infection, efficacy of treatment regime for patients with fascial space infections of odontogenic origin. Thus the markers also help in making treatment of patients with fascial space infections of odontogenic origin more cost effective and they also help protecting patients from side effects of excess drugs usage. Thus we conclude that CRP should be incorporated as monitoring tools for managing patients with fascial space infections of odontogenic origin.

  12. Dependence of the bone-to-soft-part ratios in skeletal scintigrams on the type of the malignans disease, morphological alterations visible by X-ray, laboratory parameters, age and sex of patients

    International Nuclear Information System (INIS)

    Pfeifer, H.

    1982-01-01

    This study was aimed to establish whether in tumor patients information detectable by scintigrams on diffuse pathological bone alterations can be obtained prior to or without typical foci of radioactivity being discoverable. By means of a quantitative evaluation of the scintigrams consisting in a comparison of the ratios of counting rate densities, the attempt was made to find out whether there were differences between visually ''normal'' scintigrams of patients with malignant tumors with a tendency towards metastatic spread into the skeletal system, and such same scans of patients without carcinomas showing no clinical signs of bone diseases. Laboratory values including serum creatinine as a parameter of renal function, as well as the administration of a tumor-specific therapy were additionally put in correlation with their possible influence on the accumulation of sup(99m)technetium-tin-phosphate compounds in bones. (orig./MG) [de

  13. Acquisition, processing and display of gated cardiac scintigrams

    International Nuclear Information System (INIS)

    Alpert, N.M.; Chesler, D.A.; McKusick, K.A.; Potsaid, M.S.; Pohost, G.M.; Dinsmore, R.A.

    1974-01-01

    An improved method for non-traumatic and essentially noninvasive evaluation of left ventricular (LV) function with /sup 99m/Tc as the tracer was developed. This method combines previously used EKG gating techniques for cardiac blood pool visualization with new computerized acquisition, processing and display techniques. An Anger camera, a small computer, and a physiological synchronizer are used to acquire a sequence of eight scintigrams which span the entire cardiac cycle. Under our present protocol two twenty-minute sequences are obtained, one an LAO (50 0 ) projection, the other an RAO (30 0 ) projection. Subsequently these images are processed on-line with a digital filter to increase definition of the cardiac borders. The eight images are then displayed sequentially on a specially designed electronic monitor to give an impression of the beating heart somewhat analogous to that obtained with invasive contrast angiography

  14. A simple method of digitizing analog scintigrams for quantification and digital archiving. Eine einfache Methode der Digitalisierung von Analogszintigrammen zur Quantifizierung und digitalen Archivierung

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, M. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Kaempfer, B. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Wolf, H. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Clausen, M. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Wendhausen, H. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Henze, E. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany))

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.)

  15. A new method for evaluating worst- and best-case (WBC) economic consequences of technological development

    DEFF Research Database (Denmark)

    Schjær-Jacobsen, Hans

    1996-01-01

    This paper is addressing the problem of evaluating economic worst- and best-care (WBC) consequences of technological development in industrial companies faking into account uncertainties and lack of exact cost and market information. In the theoretical part of the paper, the mathematical concepts...

  16. Indium-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Michio; Ojima, Kenji; Tsuda, Takashi [Niigata Univ. (Japan). School of Medicine

    1983-09-01

    This study was designed to evaluate the efficacy of scintigraphy by using /sup 111/In-oxine labeled platelets for the detection of either intracardiac or intravascular thrombi. Fourteen cases of thrombi diagnosed or suspected on the basis of either angiography or two-dimensional echography were examined. They included four cases of left ventricular thrombi, three of left atrial thrombi, four of vascular thrombi and three of inflammatory disease. Platelet samples from the patients were labeled by /sup 111/In-oxine according to the method originated by Yui et al. The labeling efficiency was 72.4+-9.8%. The platelets retained good function except for collagen aggregability. Hot areas of high quality in the scintigram were demonstrated in six cases including two with left ventricular thrombi, two with left atrial thrombi and two with vascular thrombi. These areas accorded well with the findings of angiography, echography or surgery. The removed thrombi had a layer of aggregated platelets on the surface. Platelet survival was shortened in a case of prosthetic valve endocarditis without a hot area, and was normal in four out of the five cases including two with a hot area. It is concluded that this method is potentially predictive in detecting thrombi.

  17. The whole-body scintigram with sup(99m)Tc-albumin microspheres for the determination of central and pulmonary right-to-left shunts

    International Nuclear Information System (INIS)

    Anger, K.

    1980-01-01

    In about 1970 the detection of cardiac and pulmonary right-to-left shunts by means of the intravenous injection of Technetium 99-marked albumin-macroaggregates was introduced and until now this determination method is the most simple and most precisely one. After the injection the main part of the particles reaches the lungs and is fixed there, the shunt-part is fixed in the systemic circulation in the organs with the best blood supply, i.e. brain, kidneys and liver. From a quantitative whole-body scintigram or from partial scintigrams of head, lungs and abdomen the relation of pulmonary and extrapulmonary activity is calculated, which corresponds precisely to the proportional right-to-left shunt. This method is illustrated by examples of its clinical application. (orig.) [de

  18. Radionuclide Generator ^{111}In\\to^{111m}Cd

    CERN Document Server

    Filossofov, D V; Lebedev, N A; Starodub, G Ya; Novgorodov, A F

    2001-01-01

    Radionuclide generator ^{111}In\\to^{111m}Cd with chemical yield > 95 % and contamination of the ^{111m}Cd by parent isotope (^{111}In) less than 0.6 % (of ^{111m}Cd activity) is developed. Extraction chromatography with di-2-ethylhexyl-phosphoric acid as an extragent is used for the radiochemical separation of the parent and the daughter radionuclides. Probability of the electron capture on the isomeric level 396 keV (^{111m}Cd) in the ^{111}In decay process is determinated to be (6.01\\pm 0.14_{stat}\\pm0.18_{syst})\\cdot10^{-5}.

  19. Whole-Body Counter(WBC) and food radiocesium contamination surveys in Namie, Fukushima Prefecture.

    Science.gov (United States)

    Hosokawa, Yoichiro; Nomura, Kazuki; Tsushima, Eiki; Kudo, Kohsei; Noto, Yuka; Nishizawa, Yoshiko

    2017-01-01

    This study examined the internal Cs exposure of residents and the Cs present in food products produced in Namie. Whole-body counter (WBC) was used for the measurement of internal exposure per each whole body of examinees. The food products which appeared to be used for consumption, were brought by residents and commercially available food items were excluded. Most of them were wild plants or food items produced by residents. Four years of data from April 2012 to March 2013 (fiscal 2012) and April 2015 to March 2016 (Fiscal 2015) were analyzed and studied. The average radioactivity measured by WBC was approximately 5 Bq for Cs-134, and 20 Bq for Cs-137 and the average committed effective dose was approximately 1 μSv. The average for the residents with detectable radioactivity was 25 μSv, and the human health effects are considered to be extremely low risk. However, the radioactivity of the affected individuals showed a higher value than the theoretical attenuation rate. The majority (83.2%) of individuals exhibiting radioactivity were over 50 years old. The number of food products brought in for detection decreased as the study period progressed, but the number of food products with radioactivity had increased. While the items with a higher detection rate of radioactivity included fruits such as citron and persimmon, shiitake mushrooms exhibited the highest radioactivity. Moreover, the radioactivity of seven items in these 10 items decreased from fiscal 2012 to fiscal 2015. Mushrooms had high radioactivity and were produced over a wide area. We suggest that the elderly try to enjoy life and eat wild plants in moderation while inspecting food products. Therefore, we will continue to work in raising awareness of radiation and its potential presence in food products and thus the continuing necessity of monitoring radioactivity in food in the future.

  20. Whole-Body Counter(WBC and food radiocesium contamination surveys in Namie, Fukushima Prefecture.

    Directory of Open Access Journals (Sweden)

    Yoichiro Hosokawa

    Full Text Available This study examined the internal Cs exposure of residents and the Cs present in food products produced in Namie. Whole-body counter (WBC was used for the measurement of internal exposure per each whole body of examinees.The food products which appeared to be used for consumption, were brought by residents and commercially available food items were excluded. Most of them were wild plants or food items produced by residents. Four years of data from April 2012 to March 2013 (fiscal 2012 and April 2015 to March 2016 (Fiscal 2015 were analyzed and studied.The average radioactivity measured by WBC was approximately 5 Bq for Cs-134, and 20 Bq for Cs-137 and the average committed effective dose was approximately 1 μSv. The average for the residents with detectable radioactivity was 25 μSv, and the human health effects are considered to be extremely low risk. However, the radioactivity of the affected individuals showed a higher value than the theoretical attenuation rate. The majority (83.2% of individuals exhibiting radioactivity were over 50 years old. The number of food products brought in for detection decreased as the study period progressed, but the number of food products with radioactivity had increased. While the items with a higher detection rate of radioactivity included fruits such as citron and persimmon, shiitake mushrooms exhibited the highest radioactivity. Moreover, the radioactivity of seven items in these 10 items decreased from fiscal 2012 to fiscal 2015. Mushrooms had high radioactivity and were produced over a wide area.We suggest that the elderly try to enjoy life and eat wild plants in moderation while inspecting food products. Therefore, we will continue to work in raising awareness of radiation and its potential presence in food products and thus the continuing necessity of monitoring radioactivity in food in the future.

  1. Myocardial viability in cases with persistent perfusion defects on the dipyridamole thallium-201 scintigram. A comparative study with autopsy findings

    International Nuclear Information System (INIS)

    Nakayama, Masafumi; Mashima, Saburo; Ohkawa, Shin-ichiro; Tanno, Munehiko; Yamada, Hideo.

    1996-01-01

    The aim of this study was to assess the incidence of myocardial infarction among persistent perfusion defects in dipyridamole-stress thallium scintigraphy by inspecting autopsied hearts and to evaluate whether the regional thallium activity of a scintigraphic defect can predict the presence of infarction. Autopsied hearts were compared with dipyridamole myocardial scintigrams undertaken during life in 27 patients (mean age 85±8 years). The time interval from stress testing until death was 428±351 days. Regional thallium uptake of delayed perfusion defect was calculated on the short axis images. The grade of regional myocardial fibrosis in autopsy specimens was also quantified to correlate with the corresponding regional thallium uptake. In 6 of 15 (40%) regions with persistent defects on the scintigram, myocardial infarction was not found at autopsy. Regional thallium-201 uptake of delayed defects < 50% diagnosed infarction with a sensitivity of 82% and a specificity of 80%. A linear correlation (r=-0.67) was observed between percent thallium-201 uptake and the degree of myocardial fibrosis. In conclusion, perfusion defects at 4-hour imaging in dipyridamole-stress testing may overestimate the presence of myocardial infarction and regional thallium-201 activity is helpful in distinguishing between defects with and without infarction. (author)

  2. 99mTc-annexin V and 111In-antimyosin antibody uptake in experimental myocardial infarction in rats

    International Nuclear Information System (INIS)

    Sarda-Mantel, Laure; Rouzet, Francois; Martet, Genevieve; Raguin, Olivier; Vrigneaud, Jean-Marc; Guludec, Dominique Le; Michel, Jean-Baptiste; Louedec, Liliane; Vanderheyden, Jean-Luc; Hervatin, Florence; Khaw, Ban An

    2006-01-01

    99m Tc-annexin V (ANX) allows scintigraphic detection of apoptotic cells via specific binding to exposed phosphatidylserine. In myocardial infarction, apoptosis of myocytes is variable and depends especially on the presence or absence of coronary reperfusion. In this study, ANX uptake in non-reperfused experimental myocardial infarcts was compared with uptake of a marker of myocyte necrosis ( 111 In-antimyosin antibodies, AM) and an immunohistochemical marker of apoptosis (Apostain). The left anterior coronary artery was ligated in 47 Wistar rats, which were then injected with ANX (n=20), AM (n=21) or both (n=6). Myocardial uptake of ANX and AM was determined at 2 h (n=14), 4 h (n=14) and 24 h (n=19) after coronary ligation (CL), by quantitative autoradiography with (n=23) or without (n=24) gamma imaging. Heart-to-lung ratios (HLRs) and infarct-to-remote myocardium activity ratios (INRs) were calculated on the scintigrams and autoradiograms respectively. Cardiac sections were stained with haematoxylin-eosin and Apostain. The above studies were repeated in 12 normal rats. All rats with CL showed increased ANX and AM uptake in cardiac areas on scintigrams 24 h after CL, with HLRs higher than in controls: 3.1±0.6 versus 1.5±0.3 (p=0.001) for ANX and 1.99±0.44 versus 1.01±0.05 (p<0.0005) for AM. Autoradiography showed intense ANX and AM uptake in infarcts, with comparable topography and INRs at 2 h, 4 h and 24 h after CL (4.6±0.9 versus 5.0±1.8 at 24 h), while Apostain staining was very low (0.06±0.06% of cells). In this model of persistent CL, we observed increased ANX uptake in injured myocardium, comparable in intensity, topography and kinetics to that of AM. There was only minimal Apostain staining in the same areas. (orig.)

  3. Efficacy of lung ventilation scintigram and exercise pulmonary hemodynamic measurement to evaluate operability for pulmonary resection

    International Nuclear Information System (INIS)

    Kaneda, Masanori; Hayashi, Takashi; Hiraiwa, Takane; Sakai, Takashi; Namikawa, Shoji; Kusakawa, Minoru.

    1989-01-01

    Preoperative evaluation of patients with lung cancer should include data concerning both resectability and operability. Operability addresses the question how much pulmonary tissue can be safely removed. The purpose of this study is to demonstrate an efficacy of the lung ventilation scintigram and measurement of exercise change in pulmonary hemodynamic parameters by detecting respiratory and circulatory reserve of pulmonary function. Predicted postoperative forced vital capacity (FVC) were calculated from the data of lung scintigram and preoperative spirometry by means of subsegmental formula. Accuracy of prediction was confirmed by spirometry 6 months after the operation. Correlation coefficient between predicted value and actually measured one was R=0.95, and simple regression formula was y=0.98x-10.4. It was recommended that the lower limit should be setted at 40% by the calculated postoperative %FVC. Exercise test were performed by means of bicycle ergometer with the measurement of pulmonary arterial pressure and cardiac output. Pulmonary arterial resistance index (PARI) were also calculated. In younger group rise of pulmonary arterial pressure during exercise was gentle, and PARI was settled between 150 to 200 in high output state. But in older group rise of pulmonary aerial pressure was steep and PARI was over 200 in some cases, just like the case of COLD. It should be recommended to set the upper limit of PARI at 400 in maximum exercise. (author)

  4. Digital filtering of scintigrams and an investigation into the application of the fresnel zone plate in nuclear medicine

    International Nuclear Information System (INIS)

    Berg, C.J.M. van den

    1976-01-01

    By lack of media large enough to obtain a gamma-lens gamma radiation imaging detectors are based on collimation by absorbence. At present, routine static studies in Nuclear Medicine generally make use of gamma cameras equiped with conventional collimators of limited resolution characterized by their impulse response function. Two methods of improvement of scintigraphic imaging are investigated in this thesis: i) Digital filtering of scintigrams obtained with a conventional collimator (Chapter III); ii) Use of alternative collimation techniques i.e. the use of coded apertures, especially of Zone Plates

  5. The effect of hydro-ethanolic extract of Curcuma longa rhizome and curcumin on total and differential WBC and serum oxidant, antioxidant biomarkers in rat model of asthma.

    Science.gov (United States)

    Shakeri, Farzaneh; Soukhtanloo, Mohammad; Boskabady, Mohammad Hossein

    2017-02-01

    The effects of Curcuma longa ( C. longa ) and curcumin on total and differential WBC count and oxidant, antioxidant biomarkers, in rat model of asthma were evaluated. Total and differential WBC count in the blood, NO 2 , NO 3 , MDA, SOD, CAT and thiol levels in serum were examined in control, asthma, Asthmatic rats treated with C. longa (0.75, 1.50, and 3.00 mg/ml), curcumin (0.15, 0.30, and 0.60 mg/ml), and dexamethasone (1.25 μg/ml) rats. Total and most differential WBC count, NO 2 , NO 3 and MDA were increased but lymphocytes, SOD, CAT and thiol were decreased in asthmatic animals compared to controls ( P longa and curcumin compared to asthmatic group ( P longa and curcumin ( P longa extract and its constituent curcumin in animal model of asthma was observed which suggest a therapeutic potential for the plant and its constituent on asthma.

  6. Comparative studies of 111In-labeled monoclonal antibody using spacer-containing and non-spacer bifunctional chelates. 2

    International Nuclear Information System (INIS)

    Sun, Baofu

    1994-01-01

    Indium-111-labeled A7 monoclonal antibodies using two spacer-containing chelates, succinimido-EGS-DTPA (EGS-DTPA: diester spacer) and maleimido-C10-Bz-EDTA (C10-Bz-EDTA: hydrocarbon spacer) were investigated in human LS180 colon tumor bearing nude mice and were compared with two non-spacer chelates, cyclic DTPA dianhydride (cDTPAA) and isothiocyanatobenzyl-EDTA (SCN-Bz-EDTA). Compared with immunoconjugates using non-spacer chelates, immunoconjugates using spacer-containing chelates, especially C10-Bz-EDTA-A7 showed lower 111 In activity in normal organs. The radioactivity in the liver for C10-Bz-EDTA-A7 decreased continuously till 96 hrs postinjection, however, this liver radioactivity for EGS-DTPA-A7 showed little change after 24 hrs. Moreover, in liver subcellular distribution study, EGS-DTPA-A7 showed a higher activity retention in mitochondrial fraction which contained lysosome, a place for metabolizing and storing of 111 In labeled antibody, than that of C10-Bz-EDTA-A7. The C10-Bz-EDTA-A7 conjugate demonstrated more preferable tumor-to-non tumor contrast on the scintigrams than that found with other three immunoconjugates. Up to 96 hrs postinjection, tumor bearing nude mice injecting with immunoconjugates using spacer-containing chelates exreted twice radioactivity from whole body than that excreted by using non-spacer chelates. Interestingly, different from other three chelates, C10-Bz-EDTA-A7 were mainly excreted via feces. We conclude that the decrease of radioactivity in normal tissues in the case of EGS-DTPA-A7 was due to the rapid decrease of activity in the blood, while in the case of C10-Bz-EDTA-A7 it was due to the quickly excreted small metabolite through faces. 111 In labeled C10-Bz-EDTA conjugate is superior, at least when conjugated with A7, to other three chelate conjugates used in this study. (author)

  7. Detection of deep venous thrombosis with indium 111-labelled monoclonal antibody against tissue plasminogen activator

    Energy Technology Data Exchange (ETDEWEB)

    Tromholt, N.; Hesse, B. (Hilleroed County Hospital (Denmark). Dept. of Clinical Physiology); Folkenborg, O. (Isotope-Pharmcy, Broenshoej (Denmark)); Selmer, J. (Novo Industri A/S, Bagsvaerd (Denmark)); Nielsen, N.T. (Hilleroed County Hospital (Denmark). Dept. of Radiology)

    1991-05-01

    The administration of a radiolabelled monoclonal antibody against tissue plasminogen activator allows detection of areas with increased fibrinolytic activity, i.e. those with an active thrombotic lesion. Eight patients with phlebographically verified deep venous thrombosis were examined. At the time of immunoscintigraphy study they were examined receiving anticoagulant therapy. Some 75-85 MBq {sup 111}In-labelled antibody were injected, and scintigrams were obtained after 30 min and after 24 h. The precise site of the thrombus could not be visualized after 30 min due to high background activity, whereas after 24 h it was detectable in all patients. The thrombus/background ratios achieved are twice as high as those observed in a human antifibrin antibody study. These preliminary data suggest a high sensitivity of our PA-specific antibody for the detection of active deep venous thrombosis in man, and our antibody seems to offer theoretical advantages over both platelet and fibrin-specific antibodies. (orig.).

  8. Detection of deep venous thrombosis with indium 111-labelled monoclonal antibody against tissue plasminogen activator

    International Nuclear Information System (INIS)

    Tromholt, N.; Hesse, B.; Selmer, J.; Nielsen, N.T.

    1991-01-01

    The administration of a radiolabelled monoclonal antibody against tissue plasminogen activator allows detection of areas with increased fibrinolytic activity, i.e. those with an active thrombotic lesion. Eight patients with phlebographically verified deep venous thrombosis were examined. At the time of immunoscintigraphy study they were examined receiving anticoagulant therapy. Some 75-85 MBq 111 In-labelled antibody were injected, and scintigrams were obtained after 30 min and after 24 h. The precise site of the thrombus could not be visualized after 30 min due to high background activity, whereas after 24 h it was detectable in all patients. The thrombus/background ratios achieved are twice as high as those observed in a human antifibrin antibody study. These preliminary data suggest a high sensitivity of our PA-specific antibody for the detection of active deep venous thrombosis in man, and our antibody seems to offer theoretical advantages over both platelet and fibrin-specific antibodies. (orig.)

  9. {sup 99m}Tc-annexin V and {sup 111}In-antimyosin antibody uptake in experimental myocardial infarction in rats

    Energy Technology Data Exchange (ETDEWEB)

    Sarda-Mantel, Laure; Rouzet, Francois; Martet, Genevieve; Raguin, Olivier; Vrigneaud, Jean-Marc; Guludec, Dominique Le [Bichat Hospital AP-HP, EA 3512, Nuclear Medicine Department, Paris (France); Michel, Jean-Baptiste; Louedec, Liliane [INSERM U460, UFR Bichat, Paris (France); Vanderheyden, Jean-Luc [Theseus Imaging Corporation, Boston, MA (United States); Hervatin, Florence [Bichat Hospital AP-HP, EA 3512, Nuclear Medicine Department, Paris (France); CGA/SHFS, Orsay (France); Khaw, Ban An [Bouve College of Pharmacy and Health Sciences, Center for Drug Targeting and Analysis, Boston, MA (United States)

    2006-03-15

    {sup 99m}Tc-annexin V (ANX) allows scintigraphic detection of apoptotic cells via specific binding to exposed phosphatidylserine. In myocardial infarction, apoptosis of myocytes is variable and depends especially on the presence or absence of coronary reperfusion. In this study, ANX uptake in non-reperfused experimental myocardial infarcts was compared with uptake of a marker of myocyte necrosis ({sup 111}In-antimyosin antibodies, AM) and an immunohistochemical marker of apoptosis (Apostain). The left anterior coronary artery was ligated in 47 Wistar rats, which were then injected with ANX (n=20), AM (n=21) or both (n=6). Myocardial uptake of ANX and AM was determined at 2 h (n=14), 4 h (n=14) and 24 h (n=19) after coronary ligation (CL), by quantitative autoradiography with (n=23) or without (n=24) gamma imaging. Heart-to-lung ratios (HLRs) and infarct-to-remote myocardium activity ratios (INRs) were calculated on the scintigrams and autoradiograms respectively. Cardiac sections were stained with haematoxylin-eosin and Apostain. The above studies were repeated in 12 normal rats. All rats with CL showed increased ANX and AM uptake in cardiac areas on scintigrams 24 h after CL, with HLRs higher than in controls: 3.1{+-}0.6 versus 1.5{+-}0.3 (p=0.001) for ANX and 1.99{+-}0.44 versus 1.01{+-}0.05 (p<0.0005) for AM. Autoradiography showed intense ANX and AM uptake in infarcts, with comparable topography and INRs at 2 h, 4 h and 24 h after CL (4.6{+-}0.9 versus 5.0{+-}1.8 at 24 h), while Apostain staining was very low (0.06{+-}0.06% of cells). In this model of persistent CL, we observed increased ANX uptake in injured myocardium, comparable in intensity, topography and kinetics to that of AM. There was only minimal Apostain staining in the same areas. (orig.)

  10. The effect of hydro-ethanolic extract of Curcuma longa rhizome and curcumin on total and differential WBC and serum oxidant, antioxidant biomarkers in rat model of asthma

    OpenAIRE

    Farzaneh Shakeri; Mohammad Soukhtanloo; Mohammad Hossein Boskabady

    2017-01-01

    Objective(s): The effects of Curcuma longa (C. longa) and curcumin on total and differential WBC count and oxidant, antioxidant biomarkers, in rat model of asthma were evaluated. Materials and Methods: Total and differential WBC count in the blood, NO2, NO3, MDA, SOD, CAT and thiol levels in serum were examined in control, asthma, Asthmatic rats treated with C. longa (0.75, 1.50, and 3.00 mg/ml), curcumin (0.15, 0.30, and 0.60 mg/ml), and dexamethasone (1.25 ?g/ml) rats. Results: Total and mo...

  11. Myocardial visualization on a routine perfusion lung scintigram: Relationship to the amount of right-to-left shunt

    International Nuclear Information System (INIS)

    Seto, H.; Futatsuya, R.; Kamei, T.; Kakishita, M.; Hisada, K.

    1983-01-01

    Three cases of myocardial visualization on a routine perfusion lung scintigram with sup(99m)Tc-macroaggregaed albumin were reported in patients with congenital heart diseases; two cases of tetralogy of Fallot and one case of truncus arteriosus type IV. Large right-to-left shunts greater than 39% and marked hypertrophy of the ventricle suggesting the presence of increased coronary blood flow were noted in all cases. In the two patients with tetralogy of Fallot myocardial activity appeared to be located in the hypertrophic right venticles. (orig.)

  12. Myocardial visualization on a routine perfusion lung scintigram: Relationship to the amount of right-to-left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Seto, H.; Futatsuya, R.; Kamei, T.; Kakishita, M.; Hisada, K.

    1983-11-14

    Three cases of myocardial visualization on a routine perfusion lung scintigram with sup(99m)Tc-macroaggregated albumin were reported in patients with congenital heart diseases; two cases of tetralogy of Fallot and one case of truncus arteriosus type IV. Large right-to-left shunts greater than 39% and marked hypertrophy of the ventricle suggesting the presence of increased coronary blood flow were noted in all cases. In the two patients with tetralogy of Fallot myocardial activity appeared to be located in the hypertrophic right venticles.

  13. The acetabulum: A prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Anderson, J.H.; Callaghan, J.J.

    1990-01-01

    Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy ( 111 In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111I n-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111 In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses

  14. In-situ STM study of phosphate adsorption on Cu(111), Au(111) and Cu/Au(111) electrodes

    DEFF Research Database (Denmark)

    Schlaup, Christian; Horch, Sebastian

    2013-01-01

    The interaction of Cu(111), Au(111) and Cu-covered Au(111) electrodes with a neutral phosphate buffer solution has been studied by means of cyclic voltammetry (CV) and in situ electrochemical scanning tunneling microscopy (EC-STM). Under low potential conditions, both the Cu(111) and the Au(111......) surface appear apparently adsorbate free, indicated by the presence of a (4×4) structure and the herringbone surface reconstruction, respectively. Upon potential increase, phosphate anions adsorb on both surfaces and for Cu(111) the formation of a (√3×√3)R30° structure is found, whereas on Au(111) a "(√3......×√7)" structure is formed. For a Cu-submonolayer on Au(111), coadsorption of phosphate anions leads to the formation of a (2×2) vacancy structure within an assumed pseudomorphic structure of the Cu-submonolayer with the phosphate anions occupying the vacancies. When desorbing the phosphate anions at low...

  15. Twelve years nuclear medicine - results and outlook - illustrated by 7414 cerebral scintigrams

    International Nuclear Information System (INIS)

    Klaeger, R.

    1981-01-01

    It is a fact that until the invention of computerized tomography, scintiscanning was an excellent method for diagnosing tumours, metastases, vascular processes, inflammations and traumatic lesions. Now even the differential diagnosis is possible, and also follow-up examinations are often carried out. On the basis of the 7414 considered and studied scintigrams we came to the positive result that in most cases with deliberate questions directed to specific facts, this examination procedure was applied. Scintigraphy can be considered as the predecessor of computerized tomography. With respect to differential diagnostics the following can be said: Cerebral scintigraphy measures in cases of cerebral lesions only masses, whereas the computerized tomograph permits within certain limits even the differentiation between lesion and perifocal oedema. The tomographs of the last generation even differentiate between white and grey cerebral substance. Nevertheless, the residual domaine of scintigraphy remains untouched: the patients with non-focal symptoms, including headaches, general behaviour disorders and psychiatric processes. (orig./MG) [de

  16. Effect of aspirin and ticlopidine on platelet deposition in carotid atherosclerosis: assessment by indium-111 platelet scintigraphy

    International Nuclear Information System (INIS)

    Isaka, Y.; Kimura, K.; Etani, H.; Uehara, A.; Uyama, O.; Yoneda, S.; Kamada, T.; Kusunoki, M.

    1986-01-01

    The antiplatelet effects of aspirin and ticlopidine were studied by a dual-tracer method, using indium-111 labeled platelets and technetium-99m human serum albumin, in a group of 12 patients with suspected ischemic cerebrovascular disease. The magnitude of platelet accumulation at the carotid bifurcation was expressed as the ratio of radioactivity of indium-111 platelets deposited on the vascular wall to those circulating in the blood-pool (PAI, platelet accumulation index), 48 hr after injection of labeled platelets. PAI values were measured before (baseline studies) and after the antithrombotic therapies (aspirin studies: 325 mg bid for 22.3 +/- 1.3 days, ticlopidine studies: 100 mg tid for 21.8 +/- 2.1 days). At the baseline, the mean PAI value at 24 carotid bifurcations in the patient group was 15.7 +/- 15.3% (mean +/- S.D.) compared to -4.3 +/- 9.1 at 24 carotid bifurcations in 12 normal subjects (p less than 0.01). We defined the upper limit for a normal PAI (%) value to be +13.9, namely the mean PAI plus 2 SD for the carotid bifurcation in normal subjects and used this value for semiquantitative analysis. At the baseline, significant elevation of PAI (more than 13.9%; positive scintigram) was observed at 12 of 24 vessels, while 12 other regions were negative (less than 13.9%). In the lesions with positive scintigraphic results at the baseline, the mean PAI (%) value from the baseline, aspirin and ticlopidine studies was 29.5 +/- 7.0, 11.2 +/- 8.5 (p less than 0.01 versus baseline) and 21.4 +/- 21.3 (not significant from baseline), respectively

  17. Quantitative Analysis of Bone Scintigrams at the Korle-Bu Teaching Hospital

    International Nuclear Information System (INIS)

    Huguette, E.Y.Y.

    2012-01-01

    Qualitative method of diagnosis has been the traditional means of diagnosing bone tumours at the Nuclear Medicine Department of the Korle-Bu Teaching Hospital over the years. Although this method is commendable, a more accurate diagnostic means is the quantitative approach. Study on ninety-five patients undergoing bone scans has been performed quantitatively using image J. The patients were administered with activity ranging from 15 to 30 mCi depending on their weights, and were then scanned with an installed e.Cam SPECT system. A 256 x 1024 matrix size was used in acquiring the bone scans. Quantitative analyses performed with the image J, revealed that uptake levels in all selected body parts were higher for metastatic tumours compared to non-metastatic tumours. The average normalised uptake in the recorded metastatic cases was 1.37332 cts/mm 2 /mCi and the corresponding uptake in the non-metastatic cases was 0.85230 cts/mm 2 /mCi. The relative higher uptake in metastatic tumours is attributed to high osteoblastic activity and blood flow in metastatic cases compared to non-metastatic cases. Quantitative assessment of bone scintigrams is recommended for its high accuracy and quicker means of diagnosing.(author)

  18. Au(111) and Pt(111) surface phase behavior

    DEFF Research Database (Denmark)

    Sandy, A.R.; Mochrie, S.G.J.; Zehner, D.M.

    1993-01-01

    We describe our recent X-ray scattering studies of the structure and phases of the clean Au(111) and Pt(111) surfaces. Below 0.65 of their respective bulk melting temperatures, the Au(111) surface has a well-ordered chevron reconstruction and the Pt(111) surface is unreconstructed. Above these te......We describe our recent X-ray scattering studies of the structure and phases of the clean Au(111) and Pt(111) surfaces. Below 0.65 of their respective bulk melting temperatures, the Au(111) surface has a well-ordered chevron reconstruction and the Pt(111) surface is unreconstructed. Above...

  19. Computer-aided diagnosis system for bone scintigrams from Japanese patients: importance of training database

    DEFF Research Database (Denmark)

    Horikoshi, Hiroyuki; Kikuchi, Akihiro; Onoguchi, Masahisa

    2012-01-01

    higher performance than the corresponding CAD software trained with a European database for the analysis of bone scans from Japanese patients. These results could at least partly be caused by the physical differences between Japanese and European patients resulting in less influence of attenuation......Computer-aided diagnosis (CAD) software for bone scintigrams have recently been introduced as a clinical quality assurance tool. The purpose of this study was to compare the diagnostic accuracy of two CAD systems, one based on a European and one on a Japanese training database, in a group of bone...... scans from Japanese patients.The two CAD software are trained to interpret bone scans using training databases consisting of bone scans with the desired interpretation, metastatic disease or not. One software was trained using 795 bone scans from European patients and the other with 904 bone scans from...

  20. Comparison of in-vivo kinetics of an antibody cocktail containing 131-iodine anti-CA-19/9 and 131-iodine anti-CEA with 111-indium labelled monoclonal anti-CA-19/9 using a tumor model in mice

    International Nuclear Information System (INIS)

    Koenig, S.; Orth, M.; Henze, E.

    1993-01-01

    In this study the potential diagnostic value of an 111-In-labelled CA-19/9-F (ab)-fragment was compared to that of an antibody cocktail of 131-iodine-labelled CA-19/9 and 131-iodine-labelled anti-CEA for identification of pancreas cancer by a nude mice model. 111-In-labelled CA-19/9 and the 131-iodine antibody cocktail were injected into 35 nude mice xenotransplantated with human pancreas cancer. Scintigrams were obtained and the relative distribution of activity in tumor and in several organs were determined by ROI-technique. These values were compared with the in vitro results of organ measurement after dissection of nude mice. Blood pool of 131-iodine-labelled antibodies showed only a nuclide accumulation in the thyroid because of very high rate of dejodination and missing blockade of thyroid. Other organs were not detectabel in scintigraphy because of high nucleotide accumulation of thyroid. The tumor-to-blood-ratio of organ-measurements was 18±4.3, kidneys-background-ratio 2.1±7.3, liver-background-ratio 5.8±2.0. These results are similar to those of 111-In-labelled fragments. Thus it is established that antibody cocktail had no essential advantage over singular antibody in mouse model. It gives a good tumor contrast with tumor-background-quotient of 15±7.4 measured by scintigraphy and tumor background-quotient 18±4.3 in-vitro-organ-measurement. (orig.) [de

  1. Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: A multicenter trial

    International Nuclear Information System (INIS)

    Van Train, K.F.; Maddahi, J.; Berman, D.S.; Kiat, H.; Areeda, J.; Prigent, F.; Friedman, J.

    1990-01-01

    The accuracy of the previously developed and validated Cedars-Sinai Medical Center (CSMC) computer program for quantitative analysis of thallium-201 ( 201 TI) stress myocardial tomograms was assessed in a multicenter trial consisting of 242 patients with coronary angiography and 76 with a low likelihood (LL) of coronary artery disease (CAD) involving various cameras, computers, and operators. The program utilized gender-matched normal limits developed from 35 LL patients at CSMC. The multicenter results as compared to those of 168 patients from CSMC were not significantly different with respect to the overall sensitivities (94% versus 95%) and specificities (44% versus 56%) for identification of CAD and normalcy rates which were determined in LL patients (82% for both) and with respect to identification of individual diseased arteries. The results indicate that our method for quantifying tomographic 201 TI stress scintigrams utilizing standard normal limits can be applied at other institutions by different operators, using a variety of cameras and computers, with similar accuracy to that currently obtained at our institution

  2. Prognosis with chest pain and normal thallium-201 exercise scintigrams

    International Nuclear Information System (INIS)

    Pamelia, F.X.; Gibson, R.S.; Watson, D.D.; Craddock, G.B.; Sirowatka, J.; Beller, G.A.

    1985-01-01

    The goal of this study was to determine the prognostic value of a normal exercise thallium-201 (TI-201) scintigram by quantitative criteria in a consecutive series of 349 patients with chest pain. Follow- up was obtained in 345 patients (99%) from 8 to 45 months (mean 34 +/- 7). Of these, 60% were men, 26% had typical angina, 21% had chest pain during exercise testing, 29% were unable to achieve 85% or more of maximal predicted heart rate, and in 9% ischemic ST depression (1.0 mm or greater) developed during exercise. At the time of exercise testing, 45% of patients were taking nitrates and 38% were receiving a beta- blocking drug. During the follow-up period, there were 5 cardiac deaths (0.51%/year), of which 2 were sudden, 6 patients had a nonfatal myocardial infarction (MI) (0.61%/year). Two of the 5 patients who died and 1 who had MI had angiographically normal coronary arteries. The event rate was significantly higher (p less than 0.01) in patients referred for early catheterization (5 of 53; 9%) compared with the rate for those not undergoing early angiography (6 of 298; 2%). However, the event rate was similar in those who underwent catheterization with angiographically normal coronary arteries and in those who had significant coronary artery disease

  3. Studies of bone marrow scintigrams with sup(99m)technetium sulfur colloid on various hematological disorders

    International Nuclear Information System (INIS)

    Mizuno, Takashi

    1984-01-01

    One hundred and eighty-five bone marrow scintigraphy on the whole body was performed on eight healthy adults and 151 patients with various hematologic diseases including 64 leukemia, 41 anemia, 23 other malignancy, etc. The positions of the investigated bone marrow were divided into the central marrow (five positions on the trunk bones) and the peripheral marrow (11 positions on the upper and 11 positions on the lower extremities) on the scintigram. The bone marrow scintigram was estimated by following three criteria. The first, ''Yuu-ryoiki'' (positive area), was the existence of sup(99m)Tc sulfur colloid accumulation on bone marrow (two grades; presence or absence). The second, ''Bunpu-kei'' (distribution form), was the extent of the sup(99m)Tc accumulation area of the investigated bone marrow and was divided into five grades. The last, ''Kido'' (intensity of radioactivity), was the density of the sup(99m)Tc accumulation on the area and was divided into five grades. Using this estimation, in the diseases with bone marrow hyperplasia such as Primary Thrombocythemia and Hemolytic Anemia, ''Yuu-ryoiki'' was enlarged, ''Bunpu-kei'' was extended, and ''Kido'' was increased comparing with those in healty adult. In contrast, in the diseases with bone marrow hypoplasia such as Myelofibrosis and Aplastic Anemia, ''Yuu-ryoiki'' was reduced, ''Bunpu-kei'' was contracted, and ''Kido'' was decreased. However, the enlargement of ''Yuu-ryoiki'' did not always mean bone marrow hyperplasia. The author could evaluate not only the range and distribution of hemopoiesis as a whole in malignant or benign diseases but also the residual effective hemopoiesis to know the suitable time of the initiation of the therapy or to predict the prognosis of these cases. In this study it was shown that the bone marrow scintigraphy with sup(99m)Tc sulfur colloid was an useful method to estimate the hemopoietic activity of the bone marrow. (J.P.N.)

  4. Studies of bone marrow scintigrams with sup(99m)technetium sulfur colloid on various hematological disorders

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, Takashi (Hiroshima Univ. (Japan). Research Inst. for Nuclear Medicine and Biology)

    1984-02-01

    One hundred and eighty-five bone marrow scintigraphy on the whole body was performed on eight healthy adults and 151 patients with various hematologic diseases including 64 leukemia, 41 anemia, 23 other malignancy, etc. The positions of the investigated bone marrow were divided into the central marrow (five positions on the trunk bones) and the peripheral marrow (11 positions on the upper and 11 positions on the lower extremities) on the scintigram. The bone marrow scintigram was estimated by following three criteria. The first, ''Yuu-ryoiki'' (positive area), was the existence of sup(99m)Tc sulfur colloid accumulation on bone marrow (two grades; presence or absence). The second, ''Bunpu-kei'' (distribution form), was the extent of the sup(99m)Tc accumulation area of the investigated bone marrow and was divided into five grades. The last, ''Kido'' (intensity of radioactivity), was the density of the sup(99m)Tc accumulation on the area and was divided into five grades. Using this estimation, in the diseases with bone marrow hyperplasia such as Primary Thrombocythemia and Hemolytic Anemia, ''Yuu-ryoiki'' was enlarged, ''Bunpu-kei'' was extended, and ''Kido'' was increased comparing with those in healthy adult. In contrast, in the diseases with bone marrow hypoplasia such as Myelofibrosis and Aplastic Anemia, ''Yuu-ryoiki'' was reduced, ''Bunpu-kei'' was contracted, and ''Kido'' was decreased. However, the enlargement of ''Yuu-ryoiki'' did not always mean bone marrow hyperplasia. The author could evaluate not only the range and distribution of hemopoiesis as a whole in malignant or benign diseases but also the residual effective hemopoiesis to know the suitable time of the initiation of the therapy or to predict the prognosis of these cases. In this study it was shown

  5. A study on relationship between liver scintigram and various kinds of liver function tests

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    1975-01-01

    The relationship between GOT, γ-globulin, alkaline phosphatase, ICG-R 15 and liver scintigram (anterior view) was studied in 37 patients with miscellaneous liver diseases. The length of the splenic image and the difference between right side and left side widths of the liver were indicated as liver scintigraphic findings. 1. γ-globulin and alkaline phosphatase tended to be slightly higher with remarkable splenic image. 2. All three patients with over 35% of ICG-R 15 had atrophic type of the right lobe showing more than 13 cm of the spleen. At first sight, they were diagnosed as having liver cirrhosis. On the other hand, some of the patients who had normal or slightly abnormal ICG-R 15 were suspected of having liver cirrhosis because of the long splenic image, but all had remarkable swelling of the right lobe. 3. The patients whom the difference between the right side and the left side widths was below 3 cm contained many patients with liver cirrhosis acompanied by atrophic type of the right lobe and remarkably abnormal ICG-R 15 . (Namekawa, K.)

  6. Diagnostic values of bone scintigram for painful disorders of the hand and the wrist

    International Nuclear Information System (INIS)

    Ogura, Kazuhisa; Yamauchi, Yasuo; Kusunose, Koichi; Sugiyama, Masaru; Honjou, Yuji

    1998-01-01

    From April 1993 to April 1997, 43 patients underwent bone scintigraphic examination for various painful conditions in the hand and the wrist joint. Three hours after an intravenous injection of 740 MBq of TC-99m HMDP, wrist scintigram was obtained. Of 18 patients with ulnar wrist pain, 12 patients had positive scan. The accumulation pattern in the five cases of ulnocarpal abutment syndrome showed different patterns. Slight difference of the accumulation between the ulnar head and the ulnar styloid process was well differentiated. Each carpal bone could be well identified, but when two bones were overlapping as in the triquetrum and the pisiform, additional physical findings were helpful. Six patients showed negative scan. The two patients with positive triangular fibrocartilage (TFC) tear but with negative bone scan showed no bony involvement, whereas those with TFC tear and positive scan were the ones having some bony disorders such as ulnocarpal abutment syndrome. Of 25 patients with wrist pain other than ulnar pain, 14 patients had positive scan. The remaining 11 patients who had negative scan included three patients with occult ganglion, two with wrist sprain and six with various disorders. (K.H.)

  7. Diagnostic values of bone scintigram for painful disorders of the hand and the wrist

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, Kazuhisa; Yamauchi, Yasuo; Kusunose, Koichi; Sugiyama, Masaru; Honjou, Yuji [Juntendo Univ., Tokyo (Japan). School of Medicine

    1998-02-01

    From April 1993 to April 1997, 43 patients underwent bone scintigraphic examination for various painful conditions in the hand and the wrist joint. Three hours after an intravenous injection of 740 MBq of TC-99m HMDP, wrist scintigram was obtained. Of 18 patients with ulnar wrist pain, 12 patients had positive scan. The accumulation pattern in the five cases of ulnocarpal abutment syndrome showed different patterns. Slight difference of the accumulation between the ulnar head and the ulnar styloid process was well differentiated. Each carpal bone could be well identified, but when two bones were overlapping as in the triquetrum and the pisiform, additional physical findings were helpful. Six patients showed negative scan. The two patients with positive triangular fibrocartilage (TFC) tear but with negative bone scan showed no bony involvement, whereas those with TFC tear and positive scan were the ones having some bony disorders such as ulnocarpal abutment syndrome. Of 25 patients with wrist pain other than ulnar pain, 14 patients had positive scan. The remaining 11 patients who had negative scan included three patients with occult ganglion, two with wrist sprain and six with various disorders. (K.H.)

  8. Bone marrow scintigraphy with 111In-chloride

    International Nuclear Information System (INIS)

    Aburano, Tamio; Ueno, Kyoichi; Sugihara, Masami; Tada, Akira; Tonami, Norihisa

    1977-01-01

    It is assumed that 111 In-chloride is bound to serum transferrin and then transported into reticulocyte in erythropoietic marrow. However, several biochemical differences between radioiron and 111 In have been reported since these years. In present study, clinical usefulness of 111 In-chloride bone marrow scintigraphy was examined especially by comparing 111 In-chloride image with sup(99m)Tc-colloid. Obtained results are as follows: 1) In most cases, both 111 In-chloride and sup(99m)Tc-colloid images showed similar bone marrow distributions. 2) In three out of 7 cases with hypoplastic anemia and two patients with bone marrow irradiation (700-1,000 rad), the central marrow or irradiated marrow showed marked decreased uptake of 111 In, and showed normal uptake of sup(99m)Tc. 3) In two out of 3 cases with chronic myelogenous leucemia, central marrow showed normal uptake of 111 In, and showed decreased uptake of sup(99m)Tc. From the present study, the same dissociation findings as those between radioiron and radiocolloid could be obtained in hypoplastic anemia and bone marrow irradiation. 111 In-chloride would appear to be a useful erythropoietic imaging agent, although further study of exact comparison with radioiron should be necessary. (auth.)

  9. Comparision of indium-111 oxinate labelled autologous granulocytes with indium-111 oxinate and indium-111 chloride as abscess scanning agents

    International Nuclear Information System (INIS)

    Goedemans, W.T.; Hardemann, M.R.; Belfer, A.J.

    1980-01-01

    Bacterial abscesses were evoked in goats. Imaging of these abscesses was obtained by means of labelling autologous granulocytes with 111 In oxinate, reinjection of the cells into the animal, and scintigraphy by gamma camera one day later. Comparable imaging results, however, were obtained after intravenous of 111 In oxinate or of 111 In chloride. The gamma camera images were supported by tissue distribution studies. In the case of administration of 111 In oxinate to the goats, the radioactivity accumulated in the cell fraction of the blood to a significant extent. This did not occur in the case of plain 111 In chloride. It remained unexplained why such different accumulation in cells did not result in differences in the scintigraphic studies. Blood clearance studies supplied conclusive evidence that the granulocytes stayed in the circulation for several days following labelling with 111 In oxinate and reinjection of the cells into the animals. (orig.) [de

  10. Comparison of 111In-DOTA-DPhe1-Tyr3-octreotide and 111In-DOTA-lanreotide scintigraphy and dosimetry in patients with neuroendocrine tumours

    International Nuclear Information System (INIS)

    Rodrigues, Margarida; Virgolini, Irene; Traub-Weidinger, Tatjana; Li, Shuren; Ibi, Bettina

    2006-01-01

    Somatostatin receptor scintigraphy with 111 In-DOTA-DPhe 1 -Tyr 3 -octreotide ( 111 In-DOTA-TOC) and 111 In-DOTA-lanreotide ( 111 In-DOTA-LAN) has been used for staging of neuroendocrine tumours (NETs). However, the comparative diagnostic value of these radioligands on a lesion basis has not yet been established. The aim of this study was to compare the diagnostic capacity of 111 In-DOTA-TOC and 111 In-DOTA-LAN scintigraphy in patients with NETs, evaluating whether significant differences exist in lesion imaging with these radioligands. Furthermore, dosimetric data were compared. Forty-five patients with NETs were investigated with 111 In-DOTA-TOC and 111 In-DOTA-LAN scintigraphy. Scintigraphic results were compared with those of conventional imaging and/or surgery in each patient, and also 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET) in 20 patients. 111 In-DOTA-TOC and 111 In-DOTA-LAN scintigraphy were true positive in 42/45 (93%) and 39/45 (87%) patients, and imaged 74/91 (81%) and 73/91 (80%) tumour lesions, respectively. 111 In-DOTA-TOC and 111 In-DOTA-LAN detected liver metastases in 21 and 14 patients, mediastinal metastases in seven and 11 patients, and bone metastases in two and seven patients, respectively. These radioligands revealed lesions not seen by conventional imaging in seven and eight patients, respectively, or by 18 F-FDG-PET in eight and seven patients, respectively. The estimated tumour absorbed doses for 90 Y-DOTA-TOC were higher than those for 90 Y-DOTA-LAN in 14 patients, whereas the opposite was true in 12 patients. Both 111 In-DOTA-TOC and 111 In-DOTA-LAN are suitable for imaging tumour lesions in patients with NETs and can detect lesions that may not be seen by conventional imaging and 18 F-FDG-PET. Compared with 111 In-DOTA-LAN, 111 In-DOTA-TOC has a superior diagnostic capacity for liver metastases, but a lower diagnostic capacity for metastatic lesions in mediastinum and bone. (orig.)

  11. Comparison of 111In-oxine and 111In-acetylacetone for the labeling of cells: in vivo and in vitro biological testing

    International Nuclear Information System (INIS)

    Mathias, C.J.; Heaton, W.A.; Welch, M.J.

    1981-01-01

    Several complexes of indium were compared as cell labels: indium-111-acetylacetone, indium-111-oxine, and indium-111-chloride complexed with 8-hydroxyquinoline (oxine) immediately prior to use. In labeling with acetylacetone, it was shown that the labeling efficiency is directly proportional to the amount of acetylacetone present, but the cell viability (as measured by in vitro aggregation studies), is inversely proportional to the amount of acetylacetone present. Biological studies were carried out in dogs using indium-111-labeled platelets; survival times and recovery values obtained with platelets labeled using all three techniques were similar. The same solutions were also used to label white blood cells; labeling efficiencies of greater than 80% were obtained in all cases, and the viability (as measured by trypan blue exclusion) was high in all cases. Chemotactic ability of the white cells labeled with indium-111-oxine is higher than that of unlabeled control cells; however, cells labeled with indium-111-acetylacetone were the same as the unlabeled control cells. (author)

  12. Comparison of indium-111-oxine and indium-111-acetylacetone labelled leucocytes in the diagnosis of inflammatory disease

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Karimjee, S.; Saverymuttu, S.H.; Lavender, J.P. (Hammersmith Hospital, London (UK))

    1982-11-01

    /sup 111/In leucocyte scanning in a series of 132 patients has shown this technique to be a reliable and accurate means of diagnosing sepsis. Labelling with /sup 111/In oxine and with /sup 111/In acetylacetone gave similar values of sensitivity and specificity, and higher than those of ultrasound.

  13. Magnetic properties of Co and Fe on Pt(111), Rh(111) and Pd(111): From single atoms to ultrathin films

    Energy Technology Data Exchange (ETDEWEB)

    Lehnert, Anne; Rusponi, Stefano; Etzkorn, Markus; Moulas, Geraud; Brune, Harald [IPN, EPF-Lausanne (Switzerland); Gambardella, Pietro [CREA, Catalan Institute of Nanotechnology (Spain); Bencok, Peter [ESRF, Grenoble (France)

    2009-07-01

    Single atoms of Co on Pt(111) are known to have a giant magnetic anisotropy energy (MAE) of 9.3 meV/atom. This is due to the reduced coordination and the strong spin-orbit coupling of the Pt 5d-states. In order to study the contribution of a highly polarizable substrate to the MAE, we investigated single Co atoms on Pd(111) and Rh(111) using X-ray magnetic circular dichroism (XMCD). We find a decreasing MAE moving from a 5d-substrate (Pt) to 4d-substrates (Pd and Rh). Co has a large orbital moment L of about 0.7 independent of the substrate. The easy axis is out-of-plane for Pt(111) and Pd(111) whereas it is in-plane for Co/Rh(111). Fe has on all substrates an out-of-plane easy axis, a very small anisotropy energy, and a L/S ratio of about 0.1. With increasing coverage the coordination number of the adatom increases and generally leads to a reduced MAE and orbital moment compared to the single atom. We measure one monolayer of Co and Fe on Pt(111) and Rh(111) and find MAE values <0.5 meV/atom. For 1 ML Co we find a substantial decrease in the L/S ratio to 0.19. However, the L/S ratio for 1 ML Fe on both substrates does not change much compared with the Fe single atom.

  14. Surface Chemistry Involved in Epitaxy of Graphene on 3C-SiC(111/Si(111

    Directory of Open Access Journals (Sweden)

    Abe Shunsuke

    2010-01-01

    Full Text Available Abstract Surface chemistry involved in the epitaxy of graphene by sublimating Si atoms from the surface of epitaxial 3C-SiC(111 thin films on Si(111 has been studied. The change in the surface composition during graphene epitaxy is monitored by in situ temperature-programmed desorption spectroscopy using deuterium as a probe (D2-TPD and complementarily by ex situ Raman and C1s core-level spectroscopies. The surface of the 3C-SiC(111/Si(111 is Si-terminated before the graphitization, and it becomes C-terminated via the formation of C-rich (6√3 × 6√3R30° reconstruction as the graphitization proceeds, in a similar manner as the epitaxy of graphene on Si-terminated 6H-SiC(0001 proceeds.

  15. In vivo quantitation of platelet deposition on human peripheral arterial bypass grafts using indium-111-labeled platelets. Effect of dipyridamole and aspirin

    International Nuclear Information System (INIS)

    Pumphrey, C.W.; Chesebro, J.H.; Dewanjee, M.K.; Wahner, H.W.; Hollier, L.H.; Pairolero, P.C.; Fuster, V.

    1983-01-01

    Indium-111-labeled autologous platelets, injected 48 hours after operation, were used to evaluate the thrombogenicity of prosthetic material and the effect of platelet inhibitor therapy in vivo. Dacron double-velour (Microvel) aortofemoral artery bifurcation grafts were placed in 16 patients and unilateral polytetrafluoroethylene femoropopliteal grafts were placed in 10 patients. Half the patients in each group received platelet inhibitors before operation (dipyridamole, 100 mg 4 times a day) and after operation (dipyridamole, 75 mg, and acetylsalicylic acid, 325 mg 3 times a day); the rest of the patients served as control subjects. Five-minute scintigrams of the graft region were taken with a gamma camera interfaced with a computer 48, 72, and 96 hours after injection of the labeled platelets. Platelet deposition was estimated from the radioactivities of the grafts and expressed as counts per 100 pixels per microcurie injected. Dipyridamole and aspirin therapy significantly reduced the number of platelets deposited on Dacron grafts and prevented platelet accumulation over 3 days. With the small amount of platelet deposition on polytetrafluoroethylene femoropopliteal artery grafts even in control patients, platelet inhibitor therapy had no demonstrable effect on platelet deposition on these grafts. It is concluded that (1) platelet deposition on vascular grafts in vivo can be quantitated by noninvasive methods, and (2) dipyridamole and aspirin therapy reduced platelet deposition on Dacron aortofemoral artery grafts

  16. Thrombokinetics with In-111-oxine labelled platelets

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Yui, Tokuo; Muroi, Shuichi; Matsuda, Shin; Kariyone, Shigeo

    1982-01-01

    Indium-111-oxine has been employed as a redioactive platelet label for thrombosis imaging and thrombokinetic studies in man. To evaluate it's suitability for platelet survival and turnover, thrombokinetic studies were carried out in hematological normal subjects, in patients with idiopathic thrombocytopenic purpura (ITP) and chronic congestive splenomegaly. For In-111-oxine labelled platelets, platelets were collected by differential centrifugation from 44 ml of whole blood drawn into 6 ml of acid citrate dextrose solution. Platelet suspension was incubated with In-111-oxine, which was extracted before use by the method of Thakur and co-workers. The survival, recovery and turnover of In-111-labeled platelets were 8.6 +- 0.5 days, 63.0 +- 5.4% and 3.9 +- 0.3 x 10 4 / μl/day, respectively, which were similar with those of Cr-51 method. Platelet disappearance curves labelled with In-111 and Cr-51 simultaneously were similar in one case. In patients with ITP, platelet survival shortened in the same degree with Cr-51 method. The two simultaneous labeling studies between In-111 and Cr-51 showed no differences. In the patients with congestive splenomegaly, the same results were obtained. Thrombokinetic studies with In-111-oxine labelled platelets offer the advantages of reduced blood requirements, and the ability to perform external imaging of platelet distribution. (author)

  17. Structural and electrical properties of Ge(111) films grown on Si(111) substrates and application to Ge(111)-on-Insulator

    Energy Technology Data Exchange (ETDEWEB)

    Sawano, K., E-mail: sawano@tcu.ac.jp [Advanced Research Laboratories, Tokyo City University, 8-15-1 Todoroki, Setagaya-ku, Tokyo (Japan); Hoshi, Y.; Kubo, S. [Advanced Research Laboratories, Tokyo City University, 8-15-1 Todoroki, Setagaya-ku, Tokyo (Japan); Arimoto, K.; Yamanaka, J.; Nakagawa, K. [Center for Crystal Science and Technology, University of Yamanashi, 7 Miyamae-cho, Kofu (Japan); Hamaya, K. [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka (Japan); Miyao, M. [Department of Electronics, Kyushu University, 744 Motooka, Fukuoka (Japan); Shiraki, Y. [Advanced Research Laboratories, Tokyo City University, 8-15-1 Todoroki, Setagaya-ku, Tokyo (Japan)

    2016-08-31

    Structural and electrical properties of a Ge(111) layer directly grown on a Si(111) substrate are studied. Via optimized two-step growth manner, we form a high-quality relaxed Ge layer, where strain-relieving dislocations are confined close to a Ge/Si interface. Consequently, a density of holes, which unintentionally come from crystal defects, is highly suppressed below 4 × 10{sup 16} cm{sup −3}, which leads to significantly high hole Hall mobility exceeding 1500 cm{sup 2}/Vs at room temperature. By layer transfer of the grown Ge layer, we also fabricate a Ge(111)-on-Insulator, which is a promising template for high-performance Ge-based electronic and photonic devices. - Highlights: • A high-quality Ge layer is epitaxially grown on a Si(111) by two-step growth manner. • Growth conditions, such as growth temperatures, are optimized. • Very high hole mobility is obtained from Ge(111) grown on Si(111). • High-quality thin Ge-on-Insulator with (111) orientation is obtained.

  18. Nuclear Medicine Imaging in Pediatric Infection or Chronic Inflammatory Diseases

    NARCIS (Netherlands)

    Signore, Alberto; Glaudemans, Andor W. J. M.; Gheysens, Olivier; Lauri, Chiara; Catalano, Onofrio A.

    In this review article, we focus on the most recent applications of nuclear medicine techniques (mainly (99m)Tc/(111)In white blood cells (WBC) scan, [(18)F]-FDG-PET/CT, [(18)F]-FDG-PET/MRI, and (99m)Tc-IL-2 scintigraphy) in the study of children affected by peripheral bone osteomyelitis, fungal

  19. Indium-111 octreotide uptake in the surgical scar

    Energy Technology Data Exchange (ETDEWEB)

    Degirmenci, B.; Bekis, R.; Durak, H.; Derebeck, E. [Dokuz Eylul Univ., Izmir (Turkey). Dept. of Nuclear Medicine; Sen, M. [Dokuz Eylul Univ., Izmir (Turkey). Dept. of Radiation Oncology

    1999-07-01

    Indium-111 octreotide uptake has been reported in various somatostatin receptor positive tumors, granulomas and autoimmune diseases in which activated leucocytes may play a role, subcutaneous cavernous hemangioma and angiofibroma. We present Indium-111 octreotide uptake in a surgical abdominal scar tissue 1.5 to 6 months after surgery in a patient who had been treated for recurrent carcinoid tumor in the rectosigmoid junction. Indium-111 octreotide uptake in a surgical scar may be related to the binding to somatostatin receptors in the activated lymphocytes and fibroblasts that is previously reported. (orig.) [German] In verschiedenen Somatostatinrezeptor-positiven Tumoren, Granulomen, bei Autoimmunerkrankungen, in denen aktivierte Leukozyten eine Rolle spielen, subcutanen kavernoesen Hammangiomen und Angiofibromen wurde ueber die Anreicherung von Indium-111-Oktreotid berichtet. Wir berichten ueber die Anreicherung von Indium-111-Oktreotid in einer chirurgischen Narbe ueber dem Abdomen nach 1,5 und 6 Monaten bei einem Patienten mit einem Rezidiv-Karzinoid im rektosigmoidalen Uebergang. Die Anreicherung von Indium-111-Oktreotid in chirurgischen Narbengewebe koennte in Zusammenhang stehen mit einer Bindung an Somatostationrezeptoren in aktivierten Lymphozyten und Fibroblasten, ueber die schon berichtet wurde. (orig.)

  20. 111Ag in the Chernobyl fallout

    International Nuclear Information System (INIS)

    Winkler, R.; Rosner, G.; Hoetzl, H.

    1989-01-01

    In the course of a re-evalution of the gamma-ray spectra of air filter samples collected immediately after Chernobyl accident at Munich-Neuherberg 111 Ag has been found to contribute significantly to the total activity within the first days of the Chernobyl fallout. The maximum air concentration was measured on 1 May 1986 to be 5.4 Bq/m 3 compared with 9.7 Bq 137 Cs per m 3 . Referred to this date the total activity deposition to ground was 12±3 kBq 111 Ag per m 2 . Referred to 26 April 1986 the 111 Ag to 110m Ag ratio was found to be 53±3 and the 111 Ag to 137 Cs ratio was 1.0±0.1. It is estimated that the cesium isotopes were depleted during release and atmospheric transport by a factor of about 2 compared with the silver isotopes. (orig.)

  1. Comparative study on hydrogenation of propanal on Ni(111) and Cu(111) from density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    An, Wei, E-mail: weian@sues.edu.cn; Men, Yong; Wang, Jinguo

    2017-02-01

    Highlights: • Hydrogenation of propanal is kinetically much faster on Ni(111) than Cu(111). • Hydroxyl route is prefered over alkoxy route on Ni(111). • Alkoxy route is prefered over hydroxyl route on Cu(111). • Activation barrier for hydrogenation of carbonyl is lowered by H-tunneling effect. • η{sup 2}(C,O)-adsorption mode is beneficial for hydrogenation/dehydrogenation of aldehyde. - Abstract: Using propanal as a probe molecule, we have comparatively investigated hydrogenation of carbonyl (C=O) in short carbon-chain aldehyde on Ni(111) and Cu(111) by means of periodic density functional theory. Our focus is in particular on the differentiation of reaction route in sequential hydrogenation on Ni(111) and Cu(111) following Langmuir–Hinshelwood mechanism. Strong binding with alkoxy intermediates has great impact on altering reaction pathways on the two surfaces, where hydroxyl route via 1-hydroxyl propyl intermediate is dominant on Ni(111), but alkoxy route via propoxyl intermediate is more likely on Cu(111) due to a higher activiation barrier of initial hydrogenation in hydroxyl route. In comparison, hydrogenation of carbonyl on Ni(111) is kinetically much faster than that on Cu(111) as a result of much lower activation barrier in rate-determining step (i.e., 13.2 vs 26.8 kcal/mol) of most favorable reaction pathways. Furthermore, the discrepancy in calculated and experimental barriers can be well explained by using the concept of H-tunneling effect on bond forming with H atoms during sequential hydrogenation. The different features of electronic structure exhibited by the two metal surfaces provide insight into their catalytic behaviors.

  2. Autologous 111In-oxine-labeled granulocytes in Yersinia infections

    International Nuclear Information System (INIS)

    Becker, W.; Boerner, W.; Fischbach, W.

    1985-01-01

    Autologous 111 In-oxine-labeled granulocytes have proved to be valuable for the localization of inflammatory bowel diseases, especially Crohn's disease and ulcerative colitis. Other rare inflammatory bowel diseases also yield positive 111 In scans. One case of Yersinia infection of the terminal ileum (Yersinia enterocolitica) showing an accumulation of 111 In-oxine-labeled granulocytes 0.5, 4, and 24 h after the reinjection of the labeled cells is described. The 4-day fecal excretion of 111 In-oxine granulocytes showed a slight inflammatory activity of the terminal ileum. One negative scan is reported in a cotrimoxazole-treated patient with Yersinia infection. (orig.)

  3. Pretest clinical diagnosis of coronary artery disease and stress myocardial perfusion scintigram

    International Nuclear Information System (INIS)

    Kasalicky, J.; Kovac, I.; Lanska, V.

    2001-01-01

    To assess the probability of perfusion defects at exercise stress myocardial perfusion SPECT scintigraphy from pretest clinical diagnosis (medical personal history, previous ergometric investigation). To determine the value of clinical factors for probability of scintigraphic defects with respect to avoiding unnecessary investigation in subjects with low probability of abnormal scintigrams. 2143 subjects (1235 men, 908 women) were investigated by SPECT perfusion scintigraphy at stepwise increasing exercise stress. They were divided into three groups with regard to their medical history and exercise test at scintigraphy: subjects without any signs of coronary artery disease (CAD), patients with high likelihood of CAD (i.e., typical anginal pain, in particular at stress, positive stress ECG changes, angiographically documented important CAD) and patients after myocardial infarction (MI). Important risk factors (hypertension, diabetes, age and sex), as well as the role of revascularisation procedures, were taken into account for multiple logistic regression in order to express their importance for the odds of scintigraphic defect visualisation. Perfusion scintigraphic defects (PSD) were found in 5.2% of subjects without signs of CAD, in contrast to patients with manifest CAD (68.8% with PSD) and in those after MI (90.2% with PSD). There were other important factors corroborating the likelihood of PSD (in decreasing order of importance): diabetes, male, ECG changes at stress, increasing age. Successful revascularisation improved scintigraphic images. The examination of CAD symptom-free subjects, in particular with atypical chest discomfort, is useless. SMPS in patients after documented MI is to be carried out for other intended purposes, not for CAD diagnosis only. SMPS is highly recommended in patients with CAD symptoms and high CAD probability in order to decide further treatment and prognosis. (author)

  4. Prosthetic graft infection: limitations of indium white blood cell scanning

    International Nuclear Information System (INIS)

    Brunner, M.C.; Mitchell, R.S.; Baldwin, J.C.; James, D.R.; Olcott, C. IV; Mehigan, J.T.; McDougall, I.R.; Miller, D.C.

    1986-01-01

    The lack of a rapid, noninvasive, and accurate method to confirm or rule out prosthetic graft infection continues to constitute a compelling and vexing clinical problem. A host of adjunctive diagnostic techniques has been used in the past, but early promising results subsequently have usually not yielded acceptable sensitivity (reflecting false negatives) and specificity (reflecting false positive) data. White blood cell (WBC) indium 111 scanning has recently been added to this list. The utility and accuracy of 111 In WBC scans were assessed by retrospective review of WBC scan results in 70 patients undergoing evaluation for possible prosthetic graft infection over a 7-year period. Operative and autopsy data (mean follow-up, 18 months for survivors with negative scans) were used to confirm the 22 positive, 45 negative, and three equivocal WBC scans. The false positive rate (+/- 70% confidence limits) was 36% +/- 6% (n = 8) among the 22 patients with positive scans (44% +/- 6% [11 of 25] if the three equivocal scans are included as false positive), yielding a specificity of 85% +/- 5% and an overall accuracy rate of 88% +/- 4% (80% +/- 5% and 84% +/- 5%, respectively, if the three equivocal cases are considered as false positive). All three patients with equivocal scans ultimately were judged not to have prosthetic graft infection. As implied by the high accuracy rate, the sensitivity of the test was absolute (100% [14 of 14]); there were no false negative results

  5. 28 CFR 551.111 - Marriage.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Marriage. 551.111 Section 551.111... Pretrial Inmates § 551.111 Marriage. A pretrial inmate may request permission to marry in accordance with... marriage request of the pretrial inmate and to request their comments. ...

  6. Comparison of {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide and {sup 111}In-DOTA-lanreotide scintigraphy and dosimetry in patients with neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Margarida; Virgolini, Irene [Lainz Hospital, Institute of Nuclear Medicine, Vienna (Austria); University Clinic for Nuclear Medicine, Innsbruck (Austria); Traub-Weidinger, Tatjana [University Clinic for Nuclear Medicine, Innsbruck (Austria); University Hospital, Department of Nuclear Medicine, Vienna (Austria); Li, Shuren [University Hospital, Department of Nuclear Medicine, Vienna (Austria); Ibi, Bettina [Lainz Hospital, Institute of Physics, Vienna (Austria)

    2006-05-15

    Somatostatin receptor scintigraphy with {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide ({sup 111}In-DOTA-TOC) and {sup 111}In-DOTA-lanreotide ({sup 111}In-DOTA-LAN) has been used for staging of neuroendocrine tumours (NETs). However, the comparative diagnostic value of these radioligands on a lesion basis has not yet been established. The aim of this study was to compare the diagnostic capacity of {sup 111}In-DOTA-TOC and {sup 111}In-DOTA-LAN scintigraphy in patients with NETs, evaluating whether significant differences exist in lesion imaging with these radioligands. Furthermore, dosimetric data were compared. Forty-five patients with NETs were investigated with {sup 111}In-DOTA-TOC and {sup 111}In-DOTA-LAN scintigraphy. Scintigraphic results were compared with those of conventional imaging and/or surgery in each patient, and also {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) in 20 patients. {sup 111}In-DOTA-TOC and {sup 111}In-DOTA-LAN scintigraphy were true positive in 42/45 (93%) and 39/45 (87%) patients, and imaged 74/91 (81%) and 73/91 (80%) tumour lesions, respectively. {sup 111}In-DOTA-TOC and {sup 111}In-DOTA-LAN detected liver metastases in 21 and 14 patients, mediastinal metastases in seven and 11 patients, and bone metastases in two and seven patients, respectively. These radioligands revealed lesions not seen by conventional imaging in seven and eight patients, respectively, or by {sup 18}F-FDG-PET in eight and seven patients, respectively. The estimated tumour absorbed doses for {sup 90}Y-DOTA-TOC were higher than those for {sup 90}Y-DOTA-LAN in 14 patients, whereas the opposite was true in 12 patients. Both {sup 111}In-DOTA-TOC and {sup 111}In-DOTA-LAN are suitable for imaging tumour lesions in patients with NETs and can detect lesions that may not be seen by conventional imaging and {sup 18}F-FDG-PET. Compared with {sup 111}In-DOTA-LAN, {sup 111}In-DOTA-TOC has a superior diagnostic capacity for liver metastases, but a

  7. 7 CFR 1150.111 - Milk.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Milk. 1150.111 Section 1150.111 Agriculture Regulations... Orders; Milk), DEPARTMENT OF AGRICULTURE DAIRY PROMOTION PROGRAM Dairy Promotion and Research Order Definitions § 1150.111 Milk. Milk means any class of cow's milk produced in the United States. ...

  8. 49 CFR 28.111 - Notice.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Notice. 28.111 Section 28.111 Transportation Office of the Secretary of Transportation ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF TRANSPORTATION § 28.111 Notice. The Department shall...

  9. Automated determination of the right ventricular ejection fraction by digital processing of sup(81m)Kr scintigrams

    International Nuclear Information System (INIS)

    Elfner, R.; Vaknine, R.; Knapp, W.H.; Tillmanns, H.; Lorenz, W.J.

    1986-01-01

    A method is presented for the automated determination of the right ventricular ejection fraction (RVEF) by digital image processing of scintigrams obtained by intravenous infusion of Krypton 81m (sup(81m)Kr) dissolved in a glucose solution. End-diastolic and end-systolic sum pictures were computed by the addition of approximately 30-40 frames selected from the time-activity curve of a preliminary, manually drawn, right ventricular region of interest. After processing these two images with an adaptive Wiener filter, the right ventricular contour was determined by a recently developed algorithm using morphological and functional criteria. The RVEF was calculated for a series of 51 patients from the counts in the detected right ventricular regions in the end-diastolic and end-systolic sum images. In 16 patients without evidence of cardiopulmonary disease, the mean RVEF was 50+-6.1%. RVEF was significantly reduced in 18 patients with obstructive pulmonary disease (42+-6.5%) and in 17 patients with congestive cardiomyopathy (36+-7.1%). The correlation coefficient between two determinations of the RVEF was r=0.94. Through digital image processing, the determination of the RVEF by radioventriculography with sup(81m)Kr showed high reliability and reproducibility. (orig.)

  10. Nuclear medicine imaging of diabetic foot infection

    International Nuclear Information System (INIS)

    Capriotti, Gabriela; D'Alessandria, Calogero; Signore, Alberto; Chianelli, Marco; Prandini, Napoleone

    2005-01-01

    Full text: Osteomyelitis of the foot is the most frequent complication in diabetic patients. Nuclear medicine plays an important role in diagnosis and for therapy follow-up, using different tracers. We reviewed 57 papers on diabetic foot imaging (published from 1982 to 2004, 50 original papers and 7 reviews), for a total of 2889 lesions. Data analysis has been carried out to establish which imaging technique could be used as a 'gold standard' for diagnosis of infection and to evaluate the extent of disease and to monitor the efficacy of therapy. Data analysis revealed that three-phase bone-scan is sensitive but not specific whereas specificity and diagnostic accuracy of 99m Tc-WBC scintigraphy is higher than 111 In- WBC scintigraphy. In the forefoot leukocyte scintigraphy may be useful for diagnosis of osteomyelitis and for monitoring the response to medical treatment. In the mid/hind foot the leukocytes uptake is not related only to the presence of infected region, but it is attributed to inflammation, fractures and reparative processes. Other radiopharmaceuticals such as 99m Tc/ 111 In-HIG, radiolabelled antibody and their fragments, showed high sensibility, but lower specificity than WBC (96.8/66.5, 95.8/70.2, 91.3/62 vs 85.8/84.5). Conclusion: It emerged that in the forefoot when clinical suspicious of osteomyelitis is low and medical treatment is contemplated, three-phase bon scan is the procedure of choice. A positive test is not diagnostic for osteomyelitis, and radiolabelled WBC scintigraphy is necessary. In the mid/hind foot, diagnosis of neuropathic joint with infection is problematic. Radiolabelled WBC imaging is probably the most accurate test for determining the presence of infection. Although a negative study strongly indicate the absence of osteomyelitis, it is important to note that a positive result requires a complementary study with marrow agent. (author)

  11. Production of 111In for diagnosis in nuclear medicine

    International Nuclear Information System (INIS)

    Osso Junior, J.A.

    1982-01-01

    111 In (t sub(1/2 = 2.82d)) due to its favorable physical decay characteristics, can substitute sup(113m) In (t sub(1/2 = 1.66hr)), whose application is limited to rapid physiological studies, advantageously. A routine production method has been developed by 28 MeV alpha particle bombardment of natural silver at the CV-28 Cyclotron of the Instituto de Engenharia Nuclear. The target is dissolved in conc. nitric acid, and silver is precipitated with hydrochloric acid. Carrier-free 111 In which remains in solution is separated from 109 Cd, the decay product of 109 In, which is produced simultaneously during the irradiation, by an anion exchange resin. All the production and separation steps are made remotely, with the use of manipulators, tongs and electric and pneumatic systems. The thick target yield is 0.18 mCi/μAh and in each run 16 mCi of 111 In are produced, which can be used in nuclear medicine centers. Methods of labelling 111 In-EDTA and 111 In-DTPA have been developed. 111 In offers a favorable half-life for the study of rather slow biological processes, in which observation periods of 24-72 hrs after administration are required, e.g., cisternography, visualization of the lymphatic system, tumor localization and others. (Author) [pt

  12. 12 CFR 410.111 - Notice.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Notice. 410.111 Section 410.111 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY EXPORT-IMPORT BANK OF THE UNITED STATES § 410.111 Notice. The...

  13. Scintigraphic examinations concerning back pain

    International Nuclear Information System (INIS)

    Mueller-Brand, J.

    1983-01-01

    Radinuclide skeletal scintigraphy is recognized as a screening method for patients with back pain. The analog scintigram is a functional image with high sensitivity and low specificity. The improvement in specificity can be achieved using computer procedures as digital imaging, smoothing, contrast enhancement and profile selection to quantitate certain properties of the scan. Three-phase-skeletal scintigraphy, 67-Ga-citrate or 111-In labeled leucocytes augement the specificity, too. (orig.)

  14. 39 CFR 111.5 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false [Reserved] 111.5 Section 111.5 Postal Service UNITED STATES POSTAL SERVICE POST OFFICE SERVICES [DOMESTIC MAIL] GENERAL INFORMATION ON POSTAL SERVICE § 111.5 [Reserved] ...

  15. Preparation of Indium Pentetate Complex (111 In-DTPA)

    International Nuclear Information System (INIS)

    Shahhosseini, S.; Farshidfar, G.R.; Najafi, R.

    2000-01-01

    There is no organometallic compound of Indium know to exist naturally in the human body. However, a number of compounds prepared with 111 In have been evaluated for localization studies. The useful radioactive decay characteristics and the suitable chemical properties of the metal ion have drawn attention of many investigators resulting in the preparation of numerous 111 In labeled compounds for potential medical applications. One of them is 111 In-DTPA complex that is used for cerebral spinal fluid studies. In the present study, DTPA has been chelated with 111 In by employing various methods and then tested for its stability in vitro during storage and in human plasma. Three methods for the preparation of 11 1In-DTPA were used. In every method, labeling efficiency and radiochemical purity were determined by chromatography systems

  16. Distribution of In-111 in granulocyte and other cellular elements of blood (CEB) in human In-111-labeled mixed white cell (MWC) and platelet preparations

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Chowdhury, S.; Brown, M.L.; Wahner, H.W.

    1984-01-01

    A large number of platelets (PLT), red blood cells (RBC) are present along with granulocyte (GC) in In-111 in CEB was determined by Ficoll-Hypaque gradient (FHG) centrifugation of In-111-MWC and PLT preparation as a quality control procedure. MWC were separated by sedimentation with hydroxyethyl starch; PLT by differential centrifugation. MWC and PLT were labeled with In-111-oxine in saline, ACD-saline or with In-111-tropolone in 0.5 ml of ACD-plasma. 0.3-0.5 ml of labeled cell suspended in plasma was layered on 3 ml FHG of two densities (1.119 and 1.077 gm/ml) and spun in a clear polystyrene tube at 1800 G for 30 min. Four layers (plasma, PLT, GC, and RBC) were separated, and In-111 radioactivity in each fraction was determined with a gamma counter. Simultaneously cell types in MWC and PLT preparations were determined by Coulter counter and differential counting. Most of In-111 in In-MWC is associated with the PLT and RBC, GC/lymphocyte ratio is 6/4. GC has higher extraction efficiency than RBC and PLT. PLT preparation is pure and (96 +- 3)% of In-111 is bound to PLT, (4 +- 3)% to RBC and (0.2 +- 0.1)% to GC; PLT preparation contains PLT (97 +- 3)%, RBC (4 +- 3)% and GC (0.2 +- 0.1)%

  17. Adhesion of ultrathin ZrO2(111) films on Ni(111) from first principles

    DEFF Research Database (Denmark)

    Christensen, Asbjørn; Carter, Emily A.

    2001-01-01

    We have studied the ZrO2(111)/Ni(111) interface using the ultrasoft pseudopotential formalism within density functional theory. We find that ZrO2(111) adheres relatively strongly at the monolayer level but thicker ceramic films interact weakly with the Ni-substrate. We argue that the cohesion cha...

  18. sup 111 Ag in the Chernobyl fallout

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, R.; Rosner, G.; Hoetzl, H. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz)

    1989-01-01

    In the course of a re-evalution of the gamma-ray spectra of air filter samples collected immediately after Chernobyl accident at Munich-Neuherberg {sup 111}Ag has been found to contribute significantly to the total activity within the first days of the Chernobyl fallout. The maximum air concentration was measured on 1 May 1986 to be 5.4 Bq/m{sup 3} compared with 9.7 Bq {sup 137}Cs per m{sup 3}. Referred to this date the total activity deposition to ground was 12{plus minus}3 kBq {sup 111}Ag per m{sup 2}. Referred to 26 April 1986 the {sup 111}Ag to {sup 110m}Ag ratio was found to be 53{plus minus}3 and the {sup 111}Ag to {sup 137}Cs ratio was 1.0{plus minus}0.1. It is estimated that the cesium isotopes were depleted during release and atmospheric transport by a factor of about 2 compared with the silver isotopes. (orig.).

  19. 14 CFR 67.111 - Cardiovascular.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Cardiovascular. 67.111 Section 67.111 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN MEDICAL STANDARDS AND CERTIFICATION First-Class Airman Medical Certificate § 67.111 Cardiovascular. Cardiovascular...

  20. 7 CFR 1280.111 - Lamb.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Lamb. 1280.111 Section 1280.111 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.111 Lamb. Lamb means...

  1. Autologous /sup 111/In-oxine-labeled granulocytes in Yersinia infections

    Energy Technology Data Exchange (ETDEWEB)

    Becker, W.; Boerner, W.; Fischbach, W.

    1985-04-01

    Autologous /sup 111/In-oxine-labeled granulocytes have proved to be valuable for the localization of inflammatory bowel diseases, especially Crohn's disease and ulcerative colitis. Other rare inflammatory bowel diseases also yield positive /sup 111/In scans. One case of Yersinia infection of the terminal ileum (Yersinia enterocolitica) showing an accumulation of /sup 111/In-oxine-labeled granulocytes 0.5, 4, and 24 h after the reinjection of the labeled cells is described. The 4-day fecal excretion of /sup 111/In-oxine granulocytes showed a slight inflammatory activity of the terminal ileum. One negative scan is reported in a cotrimoxazole-treated patient with Yersinia infection.

  2. Electric-field gradients at the $^{111}In$ and $^{111m}Cd$ sites in undoped and Mg-doped $LiNbO_{3}$

    CERN Document Server

    Hauer, B; Marques, J G; Barradas, N P; Correia, J G; Agulló-López, F; Diéguez, E

    1995-01-01

    The quadrupole interaction of 111Cd in undoped (congruent) and Mg-doped LiNbO3 single crystals has been studied using the perturbed angular correlation technique after implantation of 111In and 111mCd. A stepwise-annealing procedure shows the lattice to be fully reconstructed at 773 K. Our results show that both In and Cd are in the Li position. Mg doping at 6 mol % does not have any effect on the lattice location of these impurities in LiNbO3.

  3. Indium-111 leukocyte imaging in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Uno, K.; Matsui, N.; Nohira, K.

    1986-01-01

    This study evaluates the usefulness of labeled leukocyte imaging in patients with rheumatoid arthritis. In 33 patients, the incidence of pain and swelling in 66 wrist joints and 66 knee joints was compared with the accumulation of [ 111 In]leukocytes. No accumulation of [ 111 In]leukocytes was seen in any of the patients' wrists (0/12) or knee joints (0/14) when both pain and swelling were absent. In contrast, 93% (25/27) of wrist joints and 80% (24/30) of knee joints with both pain and swelling were positive by [ 111 In]leukocyte scintigraphy. There was little correlation between the stage of the disease, as determined by radiography, and [ 111 In]leukocyte accumulation. This study suggests that [ 111 In]leukocyte imaging may be a reliable procedure for monitoring the activity of rheumatoid arthritis, especially for confirming the lack of an ongoing inflammatory response

  4. Nitric oxide reduction and oxidation on stepped Pt[n(111)x(111)] electrodes

    NARCIS (Netherlands)

    Beltramo, G.L.; Koper, M.T.M.

    2003-01-01

    The structure sensitivity of the reduction and oxidation of saturated and subsaturated NO adlayers has been studied on a series of stepped Pt[n(111)×(111)] electrodes by cyclic and stripping voltammetry experiments in sulfuric and perchloric acid solution. In agreement with earlier experimental

  5. Ordering at Si(111)/o-Si and Si(111)/SiO2 Interfaces

    DEFF Research Database (Denmark)

    Robinson, I. K.; Waskiewicz, W. K.; Tung, R. T.

    1986-01-01

    X-ray diffraction has been used to measure the intensity profile of the two-dimensional rods of scattering from a single interface buried inside a bulk material. In both Si(111)/a-Si and Si(111)/SiO2 examples there are features in the perpendicular-momentum-transfer dependence which are not expec...... are not expected from an ideal sharp interface. The diffraction profiles are explained by models with partially ordered layers extending into the amorphous region. In the Si(111)/a-Si case there is clear evidence of stacking faults which are attributed to residual 7×7 reconstruction....

  6. Indium 111. Radiation protection

    International Nuclear Information System (INIS)

    Grafstroem, G.; Joensson, B.A.; Strand, S.E.

    1989-01-01

    The radiopharmaceutucal 111 In-oxine is used in labelling of different blood cells and proteins. Due to its liquid state, there is always a risk for contamination during handling procedures. The aim of the project was to evaluate the contamination risks, when using this radiopharmaceutical. The investigation includes calculations of the absorved dose to the skin after a contamination of 111 In-oxine, including the radionuclide impurity 114 In m / 114 In. Investigations of 288 protection gloves shows that there is always a risk for contamination, when working with 111 In-oxine. On the protection gloves, we found activities normally ranging from a 100 Bq up to a few kBq. Noticeable is the contamination on the vials, already before their use. Besides 111 In we found most of the radionuclides used in nuclear medicine, with activities up to tens of kBq. The radionuclide impurity was cleary detectable but below the recommended value. The penetration of 111 In-oxine protection gloves of latex was negligible. Measurements of penetration in skin was evaluated with two independent methods; in vivo using a surface barrier detector, and by autoradiography. The measured penetration was less than a few micrometers. Calculation from the experimental contamination values show that the absorbed dose to the basal cell layer could be in order of several Gy. (authors)

  7. Diagnostic imaging of lung cancer with In-111-MDEGD

    International Nuclear Information System (INIS)

    Nakajima, Susumu; Hayashi, Hideo; Maeda, Tomio

    1987-01-01

    Indium-111-mono DTPA-ethyleneglycol Ga deuterporphyrin (In-111-MDEGD) is a new tumor imaging agent in lung cancer. The agent has been studied with golden hamsters bearing adenocarcinoma, C57 black mice bearing Lewis lung adenocarcinoma, and nude mice bearing human lung adenocarcinoma xerografts. It has been revealed that the tumor-to-lung, tumor-to-kidney, and tumor-to-blood ratios are higher for In-111-MDEGD than for Ga-67 citrate widely used in imaging tumors, and that the agent is not accumulated in inflammatory lesions. The results were encouraging enough to start clinical diagnostic trials in lung cancer. In this paper, an overview of In-111-MDEGD, along with its preliminary data, is given. (Namekawa, K.)

  8. Dosimetry of leukocytes labeled with 99Tcsup(m)-albumin colloid

    International Nuclear Information System (INIS)

    Marcus, C.S.; Hennemann, P.L.; Butler, J.A.; Kuperus, J.H.; Stabin, M.G.; Watson, E.E.

    1988-01-01

    Biodistribution, kinetics and dosimetry of 9 Tcsup(m)-albumin colloid labeled leukocytes (TAC-WBC) is described. A practical method of planar image data acquisition and processing is discussed. This method was used to obtain biodistribution data in 11 patients, two of whom were children. Dosimetry was calculated for fetuses, children and adults. The spleen is the critical organ, receiving 2.5 rad per 5 mCi procedure in adults and 3.6 rad per 2.15 mCi procedure in a 5-year-old child. These absorbed doses are about one-sixth of that absorbed from 111 In-leukocytes procedures utilizing one-tenth the administered activity of TAC-WBC. The liver and red marrow are approximately equivalent secondary target organs, each receiving about 20% of the spleen dose. Fetal doses at any stage of gestation are similar, averaging about 14 mrad per mCi of TAC-WBC administered to the mother. The dosimetry of TAC-WBC is favorable enough to permit its use in children, adults and during pregnancy. (author)

  9. Observation of local fields in ZnO using the 111Cd probe

    International Nuclear Information System (INIS)

    Sato, W.; Komatsuda, S.; Imagawa, E.; Ohkubo, Y.; Yamada, Y.

    2011-01-01

    The authors prepared the ZnO sample ( 111m Cd-CZO) that contains totally 0.5 at.% of Cd including 111m Cd, and the ZnO sample ( 111m Cd-ICZO) made by doping with 0.5 at.% of In to 111m Cd-CZO, and measured γ-ray perturbed angular correlation (PAC) spectra. They compared these measurement results with the PAC spectra that were observed in the sample ( 111 In-IZO) made by doping with 0.5 at.% of stable In isotope in addition to ( 111 In→) 111 Cd probe, and examined the two characteristics of 111 In-IZO. As for 111 In-IZO, large electric field gradient and late effect due to remarkable EC decay was observed compared with the sample ( 111 In-UZO), where several ppt level of ( 111 In→) 111 Cd probe was solely doped into ZnO. This fact suggests that In atoms and 111 In atoms flocculate locally. When this flocculating condition is made of many In atom groups, several occupation positions of 111 In can be considered, and they cannot form the single frequency component as obtained in the PAC spectra. Therefore, the results of this experiment can be understood that In atoms themselves form the pairs in the nearest position while replacing the lattice positions of Zn. In is generally stable under the condition of three valence, but it can take one valence depending on compounds. Therefore, it can be considered that if In 3+ and In + mixture in this ratio replace Zn 2+ sites, this pairs can exist from the viewpoint of charge balance. (A.O.)

  10. 39 CFR 11.1 - Establishment.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Establishment. 11.1 Section 11.1 Postal Service UNITED STATES POSTAL SERVICE THE BOARD OF GOVERNORS OF THE U.S. POSTAL SERVICE ADVISORY BOARDS (ARTICLE XI) § 11.1 Establishment. The Board of Governors may create such advisory boards as it may deem...

  11. 19 CFR 111.67 - Hearing.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Hearing. 111.67 Section 111.67 Customs Duties U.S... Revocation § 111.67 Hearing. (a) Hearing officer. The hearing officer must be an administrative law judge... right to examine all exhibits offered at the hearing and will have the right to cross-examine witnesses...

  12. Radiopharmaceuticals For Detection Of Inflammation And Infection

    International Nuclear Information System (INIS)

    Nurlaila, Z.

    2002-01-01

    Feeling of pain in the body could be caused by reaction of inflantation and infection as well. One of the methods could be used to detect the reaction is nuclear technique using radiopharmaceutical as radiotracer. Some radiopharmaceuticals having specific accunulation mechanism to diagnose the presence of inflamations and infections with satisfactory results. Among those radiophannaceuticals are technetium-99m-hexamethylpropileneamine-white blood cell ( 99m Tc-HMPAO-WBC), indium-111-oxine-white blood cell ( 111 In-oksin-WBC). technetium-99m-immunoglobuline G ( 99m Tc-lgG) and technetium-99m-infecton ( 99m Tc-infecton). In visualization using this method. the information of a serial previous medical treatment of the patient should be known, because cer1ain medicament, could influence the biological characteristic of radiopharmaceuticals and hence. a missed diagnosis could be resulted. This review discusses several radiopharmaceuticals for inflamation and infection, diagnoses their accumulation, mechanism in the body. Besides, the radiopharmaceuticals interaction with several drugs are also reviewed

  13. Indium 111 DTPA in cisternography

    International Nuclear Information System (INIS)

    Moretti, J.L.; Boumati, P.; Vilayleck, S.

    The circulation of the cerebrospinal fluid was studied in 11 patients following injection of 111 In DTPA. Because of its biological, radioactive and chemical characteristics, it is an ideal radiopharmaceutical [fr

  14. 27 CFR 40.111 - Change in location within same region.

    Science.gov (United States)

    2010-04-01

    ... same region. 40.111 Section 40.111 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND... Products Changes in Location of Factory § 40.111 Change in location within same region. Whenever a manufacturer of tobacco products intends to relocate his factory within the same region, the manufacturer shall...

  15. Precision electron-gamma spectroscopic studies in 111Cd

    International Nuclear Information System (INIS)

    Sai Vignesh, T.; Chhetri, Premaditya; Vijay Sai, K.; Gowrishankar, R.; Venkataramaniah, K.; Deepa, S.; Rao, Dwarakarani; Kailas, S.

    2011-01-01

    The energy levels of 111 Cd has formerly been considered in terms of the states available to the 63rd neutron which is in the 3s 1/2 sub-shell. Kisslinger and Sorensen have used the pairing plus-quadrupole model to predict the energy levels. In the Coulomb excitation experiment only five levels have been excited. The decay of 111 Ag has been investigated only by few workers, Burmistov and Didorenko, Shevlev et al and Goswamy et al. The previous data on level energies, gamma energies and intensities differ considerably even for intense gamma transitions. There has been no detailed study of the internal conversion spectrum. There have been no multipolarity assignments for some of the transitions. An extensive experimental investigation of the gamma and conversion electron spectra has been undertaken to provide precision spectroscopic information on the low lying levels of 111 Cd from the beta decay of 111 Ag

  16. The interplay between surface-water and hydrogen bonding in a water adlayer on Pt(111) and Ag(111)

    Energy Technology Data Exchange (ETDEWEB)

    Delle Site, Luigi [Max-Planck-Institut fuer Polymerforschung, Ackermannweg 10, D-55128 Mainz (Germany); Ghiringhelli, Luca M [Max-Planck-Institut fuer Polymerforschung, Ackermannweg 10, D-55128 Mainz (Germany); Andreussi, Oliviero [Scuola Normale Superiore, Piazza dei Cavalieri 7, 56100 Pisa (Italy); Donadio, Davide [Computational Science, Department of Chemistry and Applied Biosciences, ETH Zurich, USI-Campus, via Giuseppe Buffi 13, CH-6900 Lugano (Switzerland); Parrinello, Michele [Scuola Normale Superiore, Piazza dei Cavalieri 7, 56100 Pisa (Italy)

    2007-06-20

    The structure of a water adlayer on a Pt(111) surface is investigated by means of extensive first-principles calculations. Allowing for proton disorder, the ground state energy for the {radical}3 x {radical}3R30{sup o} structure can be found. This results from an interplay between water/metal chemical bonding and the hydrogen bonding of the water network. This picture is supported by substituting Pt(111) with Ag(111): the almost inert surface allows for the reconstruction of the hydrogen network. (fast track communication)

  17. The interplay between surface-water and hydrogen bonding in a water adlayer on Pt(111) and Ag(111)

    International Nuclear Information System (INIS)

    Delle Site, Luigi; Ghiringhelli, Luca M; Andreussi, Oliviero; Donadio, Davide; Parrinello, Michele

    2007-01-01

    The structure of a water adlayer on a Pt(111) surface is investigated by means of extensive first-principles calculations. Allowing for proton disorder, the ground state energy for the √3 x √3R30 o structure can be found. This results from an interplay between water/metal chemical bonding and the hydrogen bonding of the water network. This picture is supported by substituting Pt(111) with Ag(111): the almost inert surface allows for the reconstruction of the hydrogen network. (fast track communication)

  18. Density functional theory studies of the adsorption of ethylene and oxygen on Pt(111) and Pt3Sn(111)

    DEFF Research Database (Denmark)

    Watwe, R.M.; Cortright, R.D.; Mavrikakis, Manos

    2001-01-01

    Density functional theory, employing periodic slab calculations, was used to investigate the interactions of ethylene and oxygen with Pt(111) and Pt3Sn(111). The predicted energetics and structures of adsorbed species on Pt(111) are in good agreement with experimental data. The binding energies...... more than adsorption on two-fold and one-fold sites. Oxygen atoms bond as strongly on Pt3Sn(111) as on Pt(111), and these atoms prefer to adsorb near Sn atoms on the surface. The addition of Sn to Pt(111) leads to a surface heterogeneity, wherein ethylidyne species prefer to adsorb away from Sn atoms...

  19. 19 CFR 111.32 - False information.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false False information. 111.32 Section 111.32 Customs... CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.32 False information. A broker must... procure the giving of, any false or misleading information or testimony in any matter pending before the...

  20. 46 CFR 111.40-7 - Location.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Location. 111.40-7 Section 111.40-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Panelboards § 111.40-7 Location. Each panelboard must be accessible but not in a bunker or a cargo hold...

  1. 7 CFR 3015.111 - Cost principles.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Cost principles. 3015.111 Section 3015.111... § 3015.111 Cost principles. (a) The cost principles prescribed by subpart T of this part require prior... approvals required by the cost principles are in § 3015.196. Procedures for prior approvals required by this...

  2. False-positive 111In-pentetreotide Uptake in Gastritis

    International Nuclear Information System (INIS)

    Usmani, Sharjeel; Alshammari, Alshaima

    2013-01-01

    111 In-pentetreotide [ 111 In-octreoscan] is the most widely used radiolabeled somatostatin analog for evaluating neuroendocrine tumor overexpression of somatostatin receptors. False-positives studies of somatostatin receptor scintigraphy have been reported and often the cause is unexplained but assumed to be due to high number of somatostatin receptors in other pathologies. Causes of false-positives include visualization of the gallbladder, nasal mucosa and pulmonary hilar areas in respiratory infections, thyroid abnormalities, accessory spleens, recent Cerebrovascular accidents (CVA's) and activity at the site of a recent surgical incision. In infection or inflammation the cause of false-positive uptake is probably the result of tracer binding by somatostatin receptors on the inflammatory leukocytes. In this case report, we report, a 44-year-old male patient with false-positive 111 In-pentetreotide uptake due to gastritis

  3. 46 CFR 111.60-7 - Demand loads.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Demand loads. 111.60-7 Section 111.60-7 Shipping COAST... REQUIREMENTS Wiring Materials and Methods § 111.60-7 Demand loads. Generator, feeder, and bus-tie cables must be selected on the basis of a computed load of not less than the demand load given in Table 111.60-7...

  4. Diffuse pulmonary uptake of indium-111 chloride in idiopathic myelofibrosis

    International Nuclear Information System (INIS)

    Vieras, F.; Boyd, C.M.; Mora, P.A.

    1979-01-01

    Unusual indium-111 accumulation and extramedullary hematopoiesis in the lungs of a patient with idiopathic myelofibrosis are described. The bone marrow scan taken 24 h after intravenous injection of 111 InCl 3 faithfully depicted the abnormal distribution of marrow elements as assessed histologically at autopsy, thereby supporting the usefulness of 111 InCl 3 for marrow imaging

  5. Direct inelastic scattering of oriented NO from Ag(111) and Pt(111)

    International Nuclear Information System (INIS)

    Tenner, M.G.; Kuipers, E.W.; Kleyn, A.W.; Stolte, S.

    1991-01-01

    A pulsed supersonic and cold oriented beam of NO molecules is incident upon the (111) face of clean Ag and Pt single crystal surfaces. The steric effect in the scattered density distributions is determined by a quadrupole mass spectrometer. It is found that the steric effect in the peak in the distribution of direct inelastically scattered molecules depends linearly on the reflection angle. In all circumstances O-end collisions lead to scattering angles more inclined towards the surface than N-end collisions. For the Pt(111) surface a much stronger steric effect is measured than for the Ag(111) surface. The steric effect seems to scale with the incident normal velocity. These strong steric effects can be explained by the larger trapping probability for the N-end orientation and a leverage effect due to the high trapping probability

  6. Comparison of biological properties of 111In-labeled dimeric cyclic RGD peptides

    International Nuclear Information System (INIS)

    Zheng, Yumin; Ji, Shundong; Tomaselli, Elena; Yang, Yong; Liu, Shuang

    2015-01-01

    Introduction: In this study two 111 In-labeled dimeric cyclic RGD peptides, 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ), were evaluated as radiotracers for breast tumor imaging. The objective was to evaluate the impact of SAA, PEG 2 and 1,2,3-triazole linkers as compare to PEG 4 on the tumor uptake and excretion kinetics of 111 In radiotracers. Methods: DOTA-Galacto-RGD 2 was prepared by conjugation of Galacto-RGD 2 with DOTA-OSu in the presence of diisopropylethylamine. Its integrin α v β 3 binding affinity was determined using a whole-cell displacement assay against 125 I-echistatin bound to U87MG glioma cells, and was compared with those of c(RGDfK), DOTA-3P-RGD 2 and DOTA-3P-RGK 2 (a nonsense peptide conjugate with “scrambled” RGK sequences). 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ) were prepared and evaluated for their tumor-targeting capability and biodistribution properties in athymic nude mice bearing MDA-MB-435 breast tumor xenografts. Planar imaging studies were performed to demonstrate the utility of 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ) for breast tumor imaging. Results: IC 50 values of DOTA-Galacto-RGD 2 , DOTA-3P-RGD 2 , and DOTA-3P-RGK 2 were calculated to be 27 ± 2, 29 ± 4, 596 ± 48 nM, respectively. The tumor uptake values of 111 In(DOTA-Galacto-RGD 2 ) (6.79 ± 0.98, 6.56 ± 0.56, 4.17 ± 0.61 and 1.09 ± 0.13 %ID/g at 1, 4, 24 and 72 hours p.i., respectively) were almost identical to those of 111 In(DOTA-3P-RGD 2 ) (6.17 ± 1.65, 5.94 ± 0.84, 3.40 ± 0.50 and 0.99 ± 0.20 %ID/g, respectively). 111 In(DOTA-Galacto-RGD 2 ) had a faster clearance from blood and muscle than 111 In(DOTA-3P-RGD 2 ), leading to higher tumor/blood and tumor/muscle ratios. 111 In(DOTA-3P-RGD 2 ) had lower liver uptake and better tumor/liver ratios than 111 In(DOTA-Galacto-RGD 2 ). The tumor uptake of 111 In(DOTA-Galacto-RGD 2 ) and 111 In(DOTA-3P-RGD 2 ) was both integrin α v β 3 and RGD-specific. Imaging data suggest

  7. Colorectal transport during defecation in subjects with supraconal spinal cord injury

    DEFF Research Database (Denmark)

    Rasmussen, Mikkel Mylius; Krogh, Klaus; Clemmensen, Dorte

    2013-01-01

    Hospital, Denmark. Methods: Colorectal contents were marked by oral intake of 111In-coated resin pellets. Movement of stools at defecation was assessed by comparing scintigrams performed before and just after defecation. Results from 15 subjects with SCI (14 males, median age¼47 years (range: 22–74 years...... at defecation was associated with the St Mark’s fecal incontinence score (P¼0.02) but not with the Cleveland constipation score (P¼0.17), the neurogenic bowel dysfunction score (P¼0.12) or GITT (P¼0.99). Conclusion: Supraconal SCI results in significantly reduced emptying of stools at defecation...

  8. Theoretical study of the surface resistivity of (111) surfaces of NixPt1-x(111) alloys

    International Nuclear Information System (INIS)

    Rous, P. J.

    2001-01-01

    A layer-Korringa - Kohn - Rostoker calculation is used to study the compositional dependence of the surface resistivity of the (111) surface of Ni x Pt 1-x (111) alloys. The compositional disorder in the bulk and at the surface is described by the coherent potential approximation. If it is assumed that the atomic planes near the (111) surface Ni x Pt 1-x have the same composition as the bulk layers, then a weak Nordheim effect is observed in the compositional dependence of the surface resistivity. However, we show that surface segregation in Ni x Pt 1-x (111) causes an inverse Nordheim dependence in the actual surface resistivity as the bulk composition is varied. [copyright] 2001 American Institute of Physics

  9. Value of 111In-DOTA-lanreotide and 111In-DOTA-DPhe1-Tyr3-octreotide in differentiated thyroid cancer: results of in vitro binding studies and in vivo comparison with 18F-FDG PET

    International Nuclear Information System (INIS)

    Rodrigues, Margarida; Virgolini, Irene; Traub-Weidinger, Tatjana; Leimer, Maria; Li, Shuren; Dudczak, Robert; Andreae, Fritz; Angelberger, Peter

    2005-01-01

    Radioiodine-negative thyroid cancer presents diagnostic and therapeutic difficulties, warranting the implementation of new imaging and treatment strategies. The purpose of this study was twofold. First, we investigated in vitro the binding characteristics of 111 In-DOTA-lanreotide ( 111 In-DOTA-LAN) and 111 In-DOTA-DPhe 1 -Tyr 3 -octreotide ( 111 In-DOTA-TOC) to cells derived from differentiated thyroid cancer (DTC). Second, we evaluated the value of somatostatin receptor (SSTR) scintigraphy with these radioligands, as compared with 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET), for the detection of tumour lesions in DTC patients. Binding of 111 In-DOTA-LAN and 111 In-DOTA-TOC to cells isolated from surgically removed thyroid tissue was evaluated in vitro by performing saturation and displacement studies. Eighteen DTC patients with elevated thyroglobulin (12 radioiodine-negative, six radioiodine-positive) were investigated with 111 In-DOTA-LAN, 111 In-DOTA-TOC and 18 F-FDG PET scans. Large numbers of SSTR binding sites for 111 In-DOTA-LAN and 111 In-DOTA-TOC were found on the cells investigated. Both SSTR radioligands exhibited a high binding affinity for these SSTR binding sites. 111 In-DOTA-LAN and 111 In-DOTA-TOC scintigraphy detected 37 and 33 lesions, respectively, in 17 (94%) patients each, whereas 18 F-FDG PET revealed 30 lesions in 15 (83%) patients. Uptake of both SSTR radioligands was found in several radioiodine-negative sites. No striking differences in lesion imaging by 111 In-DOTA-LAN and 111 In-DOTA-TOC were found. In both radioiodine-negative and radioiodine-positive patients, more lesions were SSTR-positive/ 18 F-FDG-negative than were 18 F-FDG-positive/SSTR-negative. Adding a SSTR scan with these radioligands to the diagnostic work-up increases the diagnostic capacity in DTC, and should be considered particularly in radioiodine-negative patients with elevated thyroglobulin levels. (orig.)

  10. 46 CFR 111.20-10 - Autotransformers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Autotransformers. 111.20-10 Section 111.20-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Transformer Construction, Installation, and Protection § 111.20-10 Autotransformers. An...

  11. Identification of Ag-acceptors in $^{111}Ag^{111}Cd$ doped ZnTe and CdTe

    CERN Document Server

    Hamann, J; Deicher, M; Filz, T; Lany, S; Ostheimer, V; Strasser, F; Wolf, H; Wichert, T

    2000-01-01

    Nominally undoped ZnTe and CdTe crystals were implanted with radioactive /sup 111/Ag, which decays to /sup 111/Cd, and investigated by photoluminescence spectroscopy (PL). In ZnTe, the PL lines caused by an acceptor level at 121 meV are observed: the principal bound exciton (PBE) line, the donor-acceptor pair (DAP) band, and the two-hole transition lines. In CdTe, the PBE line and the DAP band that correspond to an acceptor level at 108 meV appear. Since the intensities of all these PL lines decrease in good agreement with the half-life of /sup 111/Ag of 178.8 h, both acceptor levels are concluded to be associated with defects containing a single Ag atom. Therefore, the earlier assignments to substitutional Ag on Zn- and Cd-lattice sites in the respective II-VI semiconductors are confirmed. The assignments in the literature of the S/sub 1/, S /sub 2/, and S/sub 3/ lines in ZnTe and the X/sub 1//sup Ag/, X/sub 2 //sup Ag//C/sub 1//sup Ag/, and C/sub 2//sup Ag/ lines in CdTe to Ag- related defect complexes are ...

  12. 111In desferal: a new radiopharmaceutical for abscess detection

    International Nuclear Information System (INIS)

    Chandra, R.; Pierno, C.; Braunstein, P.

    1978-01-01

    Desferal was labeled with 111 In and its distribution was studied in normal mice, rabbits bearing turpentine-induced abscesses, and rats bearing Staphyloccus aureus-induced abscesses. The results indicate that 111 In Desferal may be used in abscess detection and localization

  13. Scintigraphy with /sup 111/In-labeled leukocytes. Simplified procedure for labeling

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Hitoshi; Shiire, Yasushi; Koizumi, Kiyoshi; Aburano, Tamio; Tonami, Norihisa; Hisada, Kin-ichi

    1987-12-01

    To utilize /sup 111/In leukocytes in a routine work, simplified procedure for sterile leukocytes preparation and labeling with water soluble oxine sulfate was performed. Viability and chemotaxis of leukocytes were maintained during separation and labeling. Chelated rate of /sup 111/In with oxine sulfate was 93.5 %. Labeling efficiency of /sup 111/In leukocytes was 93.8 %. Obvious blood pool images due to remaind erythrocytes were not observed. /sup 111/In labeled leukocytes showed good migration into inflammatory focci.

  14. The Value of PCT, WBC and hs-CRP Tests in the Diagnosis and Prognosis of Children with Pneumonia%小儿肺炎中PCT、WBC、hs-CRP检测对疾病诊断及预后判断价值分析

    Institute of Scientific and Technical Information of China (English)

    夏兰兰; 李敬

    2017-01-01

    目的 分析小儿肺炎中PCT、WBC、hs-CRP检测对疾病诊断及预后的判断价值.方法 选取2015年5月至2016年4月在本院住院治疗的肺炎患儿120例作为观察组,健康儿童65例作为对照组.检测治疗前后患儿及健康儿童血清PCT、WBC、hs-CRP的变化.结果 治疗前,细菌感染组WBC数量(15.5±3.4)×109/L、hs-CRP水平(19.8±2.6) mg/L和PCT水平(21.9±2.1)ng/mL均明显高于非细菌感染组(6.8 ±2.3)×109/L、(4.5±2.3)mg/L、(4.7±1.8) ng/mL和健康对照组(8.1 ±1.4)×109/L、(3.5±1.2) mg/L、(1.8±0.5) ng/mL,且差异具有统计学意义(P<0.05).而非细菌感染组和健康对照组的WBC、hs-CRP和PCT结果差异无统计学意义(P>0.05);治疗后,细菌感染组WBC数量(7.3±1.4)×109/L、hs-CRP水平(5.1 ± 1.2) mg/L和PCT水平(2.3 ± 1.2) ng/mL均明显低于治疗前,差异具有统计学意义(P<0.05);WBC、hs-CRP、PCT联合检测的灵敏性95.2%、特异性93.0%、准确度93.3%显著高于WBC、hs-CRP、PCT单独检测,差异具有统计学意义(P<0.05).结论 在小儿肺炎治疗过程中,动态监测患儿血清的WBC、hs-CRP、PCT的变化,并结合临床,有助于诊疗和判断患儿疾病愈后的情况,具有显著的临床意义,值得推广应用.%Objective To estimate the value of PCT,WBC and hs-CRP tests in the diagnosis and prognosis of children with pneumonia.Methods 120 cases with pneumonia in children were selected from May 2015 to April 2016 in our hospital as the observation group,65 cases of healthy children as the control group.Changes of serum PCT,WBC and hs-CRP tests in children and healthy children before and after treatment were mearued.Results Before treatment,bacterial infection group have WBC count (15.5 ± 3.4) × 109/L,hs-CRP levels (19.8±2.6) mg/L and PCT level (21.9 ±2.1) ng/mL,which were significantly higher than those in non bacterial infection group (6.8 ±2.3) × 109/L,(4.5 ±2.3) mg/L,(4.7 ± 1.8) ng/mL and healthy control group (+ 8.1

  15. Magnetism of coherent Co and Ni thin films on Cu(111) and Au(111) substrates: An ab initio study

    Energy Technology Data Exchange (ETDEWEB)

    Zelený, Martin, E-mail: zeleny@fme.vutbr.cz; Dlouhý, Ivo

    2017-02-15

    We present an ab initio study of structural and magnetic properties of coherent Co and Ni thin films on Cu(111) and Au(111) substrates with thicknesses of up to 6 monolayers. All studied films on Cu(111) substrates prefer structures close their ground state (hcp for Co and fcc for Ni), whereas only the hcp stacking sequence has been found for both films on Au(111) substrates. All studied films exhibit instability of the first monolayer with respect to decomposition into 2-monolayer- or 3-monolayer-high islands, which is in agreement with experimental findings. All studied films are also ferromagnetic, nevertheless the Ni/Cu(111) films reduce their magnetic moments in the layer adjacent to the substrate due to a stronger Cu–Ni interaction at the interface. The magnetic anisotropy of a Co film does not depend on the film thickness: all the studied Co/Au(111) films exhibit a perpendicular magnetic anisotropy, whereas all the Co/Cu(111) films prefer in-plane magnetization. On the other hand, both Ni films change their preference for in-plane orientation of their easy axis to out-of-plane orientation at a critical thickness of 2 monolayers, however, the magnetic anisotropy energies for films thicker than 1 monolayer are smaller than 1 meV/Ni atom. These behaviors of magnetic anisotropy do not depend on the structure of the studied films. - Highlights: • All films exhibit instability of the first monolayer and prefer grow in islands. • The Cu–Ni interaction is responsible for reduced Ni magnetic moments in Ni/Cu(111) films. • The Co/Au(111) and Co/Cu(111) films show different orientations of magnetic anisotropy. • The Ni films exhibit in-plane magnetization only for single monolayer. • Behaviors of magnetic anisotropy do not depend on the structure of the studied films.

  16. 32 CFR 701.111 - Disclosure accounting.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Disclosure accounting. 701.111 Section 701.111... THE NAVY DOCUMENTS AFFECTING THE PUBLIC DON Privacy Program § 701.111 Disclosure accounting. Disclosure accounting allows the individual to determine what agencies or persons have been provided...

  17. 46 CFR 111.77-3 - Appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Appliances. 111.77-3 Section 111.77-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Appliances and Appliance Circuits § 111.77-3 Appliances. All electrical appliances, including, but...

  18. 46 CFR 111.30-5 - Construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Construction. 111.30-5 Section 111.30-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Switchboards § 111.30-5 Construction. (a) All low voltage and medium voltage switchboards (as low...

  19. 47 CFR 76.111 - Cable sports blackout.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  20. Usefulness of ECT in liver diseases

    International Nuclear Information System (INIS)

    Nishikawa, Jun-ichi

    1981-01-01

    The clinical usefulness of single photon emission tomography using rotating chair (ECT), comparing with liver scintigrams was examined with ROC (receiver operating characteristic) curve analysis. The ROC curve of ECT drew higher curved line than that of liver scintigram, i.e. true positive ratio of ECT was slightly inferior to that of liver scintigram, but false positive ratio of ECT was superior to that of liver scintigram. ECT adds useful clinical information to liver scintigram which shows questionable or suspected uptake defects. (author)

  1. Defect-induced wetting on BaF 2(111) and CaF 2(111) at ambient conditions

    Science.gov (United States)

    Cardellach, M.; Verdaguer, A.; Fraxedas, J.

    2011-12-01

    The interaction of water with freshly cleaved (111) surfaces of isostructural BaF2 and CaF2 single crystals at ambient conditions (room temperature and under controlled humidity) has been studied using scanning force microscopy in different operation modes and optical microscopy. Such surfaces exhibit contrasting behaviors for both materials: while on BaF2(111) two-dimensional water layers are formed after accumulation at step edges, CaF2(111) does not promote the formation of such layers. We attribute such opposed behavior to lattice match (mismatch) between hexagonal water ice and the hexagonal (111) surfaces of BaF2(CaF2). Optical microscope images reveal that this behavior also determines the way the surfaces become wetted at a macroscopic level.

  2. Body surface dosimetry following re-injection of 111In-leucocytes

    International Nuclear Information System (INIS)

    Mountford, P.J.; Coakley, A.J.

    1989-01-01

    The dose to a young infant cared for by a parent re-injected with 111 In-leucocytes was estimated from the exposure of thermoluminescent dosimeters at five sites on the chest wall of eight patients. The UK Guidance Notes recommend that patients with a residual activity exceeding 20 MBq of 111 In should avoid non-essential contact with children. The results confirmed those of an earlier preliminary study which showed that re-injection of 20 MBq of 111 In-leucocytes to a parent could lead to a close contact dose greater than 1 mSv. It was concluded that the 111 In-leucocyte activity administered to a parent of a young infant should not exceed 10 MBq. (author)

  3. Detection of intrathoracic infectious lesions using 111In-diethylenetriamine pentaacetic bicyclic anhydride-IgG (111In-DTPA-IgG) scintigraphy

    International Nuclear Information System (INIS)

    Ota, Tomohiro; Goto, Hajime; Wada, Hiroo; Yuasa, Kazumi; Iguchi, Mari; Okamura, Tatsuru; Ieki, Ryuji; Suzuki, Kenzo

    1998-01-01

    The utility of 111 In-DTPA-IgG imaging for the detection of intrathoracic lesions was evaluated in 10 patients with the suspicion of inflammatory or infectious diseases. They were intravenously administered 40 or 80 MBq of 111 In-DTPA-IgG, and scanned after 24 or 48 hours. Of these, 8 cases, consisted of 4 cases with pneumonia and 2 cases with lung abscess and one case of pulmonary tuberculosis and one of a tuberculous pleuritis, showed true positive results. Others were one false negative case of pneumonia and one true negative case of lung cancer. Overall sensitivity and specificity were 88.9% and 100%, respectively. There were no cases which showed side effects or abnormal laboratory findings caused by the radiopharmaceuticals administered. Thus, 111 In-DTPA-IgG imaging is a useful tool for the detection of intrathoracic infectious lesions. (author)

  4. 21 CFR 168.111 - Dextrose monohydrate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Dextrose monohydrate. 168.111 Section 168.111 Food... Table Sirups § 168.111 Dextrose monohydrate. (a) Dextrose monohydrate is purified and crystallized D.../mass (m/m), and the reducing sugar content (dextrose equivalent), expressed as D-glucose, is not less...

  5. 19 CFR 111.28 - Responsible supervision.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Responsible supervision. 111.28 Section 111.28 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.28 Responsible supervision. (a) General. Every individual broker...

  6. 45 CFR 2490.111 - Notice.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Notice. 2490.111 Section 2490.111 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE JAMES MADISON MEMORIAL...

  7. 46 CFR 111.105-41 - Battery rooms.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...

  8. Indium 111 leucocyte scintigraphy in abdominal sepsis

    International Nuclear Information System (INIS)

    Baba, A.A.; McKillop, J.H.; Gray, H.W.; Cuthbert, G.F.; Neilson, W.; Anderson, J.R.

    1990-01-01

    We have studied the clinical utility of indium 111 autologous leucocyte scintigraphy retrospectively in 45 patients presenting with suspected intra-abdominal sepsis. The sensitivity was 95% (21/22) and the specificity was 91% (21/23). Some 34 of the studies (17 positive and 17 negative) were considered helpful in furthering patient management (76%) and 8, unhelpful (18%). In 3, the study results were misleading and led to inappropriate treatment. Indium 111 scintigraphy, whether positive or negative, provides information in patients with suspected intra-abdominal sepsis upon which therapeutic decisions can be based. (orig.)

  9. 111In,113In-labelled platelets. I

    International Nuclear Information System (INIS)

    Komarek, P.; Poledne, R.; Charvat, J.; Konopkova, M.; Komarkova, I.

    1983-01-01

    111 In-8-hydroxyquinoline (oxine) is used for labelling blood platelets which serves diagnostic purposes in medicine. For the preparation of the complex of radioactive indium with oxine, 111 In and sup(113m)In were used under optimal conditions. Two different preparation methods for the labelled complex are described. Both methods studied the effect of pH, the amount of chelate agents and the mode of filtration on the yields of the labelled oxine. The blood platelets labelling is influenced not only by the quality of labelled oxine but also by their number. The organ distribution in laboratory animals proved that platelets were not impaired during separation and labelling and that they were suitable for diagnostic use. (author)

  10. First-principles study of surface plasmons on Ag(111) and H/Ag(111)

    DEFF Research Database (Denmark)

    Yan, Jun; Jacobsen, Karsten Wedel; Thygesen, Kristian Sommer

    2011-01-01

    Linear-response time-dependent density functional theory is used to investigate the relation between molecular bonding and surface plasmons for the model system H/Ag(111). We employ an orbital-dependent exchange-correlation functional to obtain a correct description of the Ag 3d band, which...... is crucial to avoid overscreening the plasmon by the s-d interband transitions. For the clean surface, this approach reproduces the experimental plasmon energies and dispersion to within 0.15 eV. Adsorption of hydrogen shifts and damps the Ag(111) surface plasmon and induces a new peak in the loss function...... at 0.6 eV below the Ag(111) plasmon peak. This feature originates from interband transitions between states located on the hydrogen atoms and states on the Ag surface atoms....

  11. One-step radiolabelled biotin scintigraphy in patients with suspected vertebral infections

    International Nuclear Information System (INIS)

    Lazzeri, E.; Erba, P.; Chinol, M.; Tascini, C.; Menichetti, F.; Paganelli, G.; Mariani, G.

    2003-01-01

    Full text: Biotin (B), or vitamin H, belonging to the B-complex group is utilized by bacteria for acid synthesis by acetyl-CoA carboxylase. We evaluated the diagnostic potential per se of radiolabeled biotin without avidin pre-targeting, in patients with suspected vertebral bacterial infections. We evaluated 31 patients for suspected spine infection. All patients were selected on clinical ground, blood chemistry findings, back pain and fever. Patients were injected i.v. with 500 μg of DTPA-conjugated Biotin labelled with 111In (110-130 MBq); planar and SPECT scans were recorded starting 90 min post-injection. All patients underwent MR, or CT and some patients were imaged with either 99mTc-HMPAO-WBC and/or 67Ga-citrate. Diagnostic-quality imaging was obtained at 90 min and 4 hr after 111In-DTPA-Biotin injection. We observed only 2 false-negative results, while 24 studies were true-positive (4 performed during follow-up) and 10 true-negative (1 during follow-up) (91% sensitivity, 100% specificity). Either MR, CT or 99mTc-HMPAO-WBC had high proportions of either false-negative, false-positive or equivocal results (sensitivity/specificity around 50%). These preliminary results outline the high diagnostic potential of one-step 111In-DTPA-Biotin scintigraphy without avidin pre-targeting) in patients with suspected vertebral infection. The high true-positive and true-negative rate suggests that this system displays some specificity for bacterial infections. The high diagnostic accuracy of 111In-Biotin scintigraphy seems to be independent from antibiotic therapy, thus making this method very helpful relative to other imaging modalities in the clinical decision on starting proper therapy and for monitoring the efficacy of treatment. (author)

  12. 111In autologous leucocytes in the diagnosis and assessment of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Saverymuttu, S.H.; Peters, A.M.; Reavy, H.J.; Danpure, H.J.; Osman, S.; Chadwick, V.S.; Hodgson, H.J.; Lavender, J.P.

    1982-01-01

    111 In-labelled leucocytes were used to obtain gamma camera images of inflamed of bowel in a wide variety of inflammatory bowel disease. No false positive scans were observed in the irritable bowel syndrome and in bowel malignancy. All patients with moderate or severely active disease had positive scans. Faecal excretion of 111 Indium increased with disease severity. 111 In-tropolone labelling appeared to offer the advantage over 111 In-acac labelling in localising inflamed bowel earlier. In many cases the bowel was imaged within 40 min of re-injection of the leucocytes. 111 In-leucocyte scanning provides a novel approach to the problem of diagnosis and assessment of inflammatory bowel disease. It is non-invasive, requires no bowel preparation and thus is safe in the acutely sick patient where conventional radiological imaging methods may be hazardous. 111 Indium faecal excretion provides an objective assessment of disease activity which should prove useful in evaluating treatment regimes

  13. Localization of indium-111 in human malignant tumor xenografts and control by chelators

    International Nuclear Information System (INIS)

    Watanabe, Naoyuki; Oriuchi, Noboru; Endo, Keigo; Inoue, Tomio; Tanada, Shuji; Murata, Hajime; Kim, E. Edmund; Sasaki, Yasuhito

    1999-01-01

    The kinetics of soluble indium-111 ( 111 In) in human malignant tumor xenografts and cells was investigated in combination with chelators. Firstly, without chelator, the kinetics of 111 In-chloride was investigated in vitro and in vivo using four human malignant neuroblastoma SK-N-MC, pulmonary papillary adenocarcinoma NCI-H441, pulmonary squamous cell carcinoma PC 9, and colon adenocarcinoma LS 180 cells and xenografts. 111 In was incorporated into tumor cells in vitro to a maximum level during a 60-min incubation. A maximum level of radioactivity was demonstrated in vivo in four human malignant tumors xenografted into nude mice at 24 h postinjection of 111 In-chloride. Secondly, the effect of edetate calcium disodium (CaNa 2 EDTA) on radioactivity in 111 In-labeled tumors xenografts and cells was studied in vitro and in vivo. CaNa 2 EDTA significantly reduced 111 In-activity from the labeled tumor xenografts, whereas it had no affect on the radioactivity in the labeled cells. Thirdly, the effect of CaNa 2 EDTA on radioactivity in human malignant tumors xenografted into nude mice injected with 111 In-chloride was investigated. In one group of mice CaNa 2 EDTA administered intraperitoneally at 1, 22, 34, 46, 58, and 70 h after injection of 111 In-chloride (postadministration), the localization of 111 In at the tumors was significantly decreased at 72 h compared with the control in all four tumor types. In the other group of mice, CaNa 2 EDTA administered intraperitoneally at 12 and 1 h before injection of 111 In-chloride and 1, 22, 34, 46, 58, and 70 h postinjection (pre- and postadministration), the radioactivity of tumors was also significantly decreased at 72 h, and the reduction was greater than that with use of postadministration. In a comparative study, CaNa 3 DTPA had a more powerful effect than CaNa 2 EDTA. In conclusion, 111 In-activity in tumors consists of intracellular and extracellular components, and the extracellular 111 In may be cleared by

  14. Gemini-IFU spectroscopy of HH 111

    Energy Technology Data Exchange (ETDEWEB)

    Cerqueira, A. H.; Vasconcelos, M. J.; Feitosa, J.; Plana, H. [LATO-DCET, Universidade Estadual de Santa Cruz Rod. Jorge Amado, km 16, Ilhéus, BA, CEP 45662-900 (Brazil); Raga, A. C., E-mail: hoth@uesc.br [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A.P. 70-543, 04510 D.F. (Mexico)

    2015-03-01

    We present new optical observations of the Herbig–Haro (HH) 111 jet using the Gemini Multi Object Spectrograph in its Integral Field Unit mode. Eight fields of 5{sup ′′}×3.{sup ′′}5 have been positioned along and across the HH 111 jet, covering the spatial region from knot E to L in HH 111 (namely, knots E, F, G, H, J, K, and L). We present images and velocity channel maps for the [O i] 6300+6360, Hα, [N ii] 6548+6583, and [S ii] 6716+6730 lines, as well as for the [S ii] 6716/6730 line ratio. We find that the HH 111 jet has an inner region with lower excitation and higher radial velocity, surrounded by a broader region of higher excitation and lower radial velocity. Also, we find higher electron densities at lower radial velocities. These results imply that the HH 111 jet has a fast, axial region with lower velocity shocks surrounded by a lower velocity sheath with higher velocity shocks.

  15. 111indium-antimyosin immunoscintigraphy in suspected myocarditis

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Joseph, A.; Moser, E.; Zeiher, A.

    1991-01-01

    111 Indium-monoclonal antimyosin scans were carried out in 21 patients with suspected myocarditis, confirmed by reduced ejection volume, pericardial effusion and clinical follow up in 12 patients. Coronary heart disease was excluded angiographically in all cases. Quantitative evaluation of myocardial 111 In-antimyosin accumulation 48 hours after injection showed a pathological uptake in 10/12 patients with increased heart/lung ratios (Q 48 >1,58). Ratios were also elevated in 2 patients with cardiomyopathy, 2 suffering from vasculitis and 1 with dermatomyositis. Four patients without proven cardiac disease had normal ratios (Q 48 ≤1,58). Examination after 24 hours was of limited value, depending on the residual blood pool activity. Visual analysis of the scans showed a high interobserver variation despite a positive correlation with quantitative analysis (48 h p.i.: r=0,72; p 111 In-antimyosin scan as a screening method prior to myocardial biopsy. However, scintigraphy cannot definitely elucidate the cause of myocardial damage. Therefore, myocardial biopsy is still recommended after positive antimyosin scans. (orig.) [de

  16. 46 CFR 111.60-5 - Cable installation.

    Science.gov (United States)

    2010-10-01

    ... REQUIREMENTS Wiring Materials and Methods § 111.60-5 Cable installation. (a) Each cable installation must meet... 46 Shipping 4 2010-10-01 2010-10-01 false Cable installation. 111.60-5 Section 111.60-5 Shipping... incorporated by reference; see 46 CFR 110.10-1), including clause 8. (b) Each cable installation made in...

  17. 49 CFR 215.111 - Defective plain bearing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Defective plain bearing. 215.111 Section 215.111... § 215.111 Defective plain bearing. A railroad may not place or continue in service a car, if the car has a plain bearing— (a) That is missing, cracked, or broken; (b) On which the bearing liner— (1) Is...

  18. Indium-111 leukocyte localization in infected prosthetic graft

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V. (Univ. of Arkansas for Medical Sciences, Little Rock (USA))

    1990-08-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection.

  19. Indium-111 leukocyte localization in infected prosthetic graft

    International Nuclear Information System (INIS)

    Purnell, G.L.; Walker, C.W.; Allison, J.W.; Dalrymple, G.V.

    1990-01-01

    Infective endocarditis can be difficult to prove, even in the face of strong clinical suspicion. A case in which standard methods of diagnosis failed to demonstrate endocarditis in a patient with recurrent Staphylococcus aureus bacteremia and porcine aortic valve is reported. An In-111 labelled leukocyte SPECT study demonstrated uptake in the aortic root and leaflets, and autopsy demonstrated vegetations on the leaflets. In-111 may prove useful in demonstrating endocarditis in patients with prosthetic valve infection

  20. Renovascular hypertension due to insufficient collateral flow in segmental artery occulusion

    International Nuclear Information System (INIS)

    Park, Y. H.; Lee, S. Y.; Kim, S. H.; Sohn, H. S.; Chung, S. K.

    2001-01-01

    We report a case in which a 33-year-old woman with renovascular hypertension due to insufficient collateral flow in segmental renal artery occlusion demonstrated abnormality on captopril renal scintigram. Baseline renal scintigram with DTPA showed normal perfusion and excretion in left kidney and captopril renal scintigram with DTPA showed a focal area of decreased perfusion and delayed clearance in lower half of left kidney, suggesting segmental renal artery stenosis. Selective left renal arteriography showed complete obstruction in proximal portion of anterior segmental artery with multiple small collateral vessels from posterior segmental artery and capsular artery and delayed opacification in lower half of left kidney. These findings are suggestive of segmental hypoperfusion due to insufficient collateral blood flow resulting to positive captopril response. Patient's blood pressure have been controlled well with ACE (angiotensin converting enzyme) inhibitor and calcium channel blocker for 2 year. Follow-up baseline renal scintigram with MAG3 showed normal perfusion and excretion in left kidney and captopril renal scintigram with MAG3 showed a focal area of decreased perfusion and delayed clearance in lower lateral portion of left kidney, which was smaller size than that of previous renal scintigram. And captopril renal scintigram with DMSA demonstrated a small area of decreased DMSA uptake on this lesion compared to baseline DMSA scintigram

  1. 7 CFR 1160.111 - Promotion.

    Science.gov (United States)

    2010-01-01

    ... demand for fluid milk products. (b) Advertising, which means any advertising or promotion program... 7 Agriculture 9 2010-01-01 2009-01-01 true Promotion. 1160.111 Section 1160.111 Agriculture... and Orders; Milk), DEPARTMENT OF AGRICULTURE FLUID MILK PROMOTION PROGRAM Fluid Milk Promotion Order...

  2. 111In-DOTA-dPhe1-Tyr3-octreotide, 111In-DOTA-lanreotide and 67Ga citrate scintigraphy for visualisation of extranodal marginal zone B-cell lymphoma of the MALT type: a comparative study

    International Nuclear Information System (INIS)

    Li, Shuren; Kurtaran, Amir; Li, Mei; Traub-Weidinger, Tatjana; Kienast, Oskar; Schima, Wolfgang; Angelberger, Peter; Virgolini, Irene; Raderer, Markus; Dudczak, Robert

    2003-01-01

    Somatostatin receptor (SSTR) scintigraphy and gallium-67 citrate ( 67 Ga) scintigraphy have been used for visualisation of Hodgkin's lymphoma and non-Hodgkin's lymphoma. However, experience with B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT) type is very limited. The aim of this study was to prospectively compare the 67 Ga scintigraphy results with those obtained by 111 In-DOTA-dPhe 1 -Tyr 3 -octreotide ( 111 In-DOTA-TOCT) and 111 In-DOTA-lanreotide ( 111 In-DOTA-LAN) scintigraphy in patients with proven MALT-type lymphoma. Comparative scintigraphic examinations using 67 Ga, 111 In-DOTA-TOCT and 111 In-DOTA-LAN were performed in 18 patients (11 female and 7 male, median age 64±15 years) with histologically verified MALT-type lymphomas of various origin. Planar and single-photon emission tomography imaging acquisitions were performed after injection of a mean dose of 185±26 MBq 67 Ga and 165±20 MBq 111 In-DOTA-TOCT or 111 In-DOTA-LAN. All scintigraphic results were correlated with other conventional examinations including gastroscopy, colonoscopy, endosonoscopy, ophthalmologic investigation, CT of the thorax and abdomen and bone marrow biopsy. This comparative study showed that 67 Ga scintigraphy found abnormalities in 10 of 16 patients (63%) and detected 18 of 31 clinically involved sites (58%), but was false positive in three patients. 111 In-DOTA-TOCT found abnormalities in 9 of 15 patients (60%) and detected 15 of 27 clinical lesions (56%); it was false positive in two patients. 111 In-DOTA-LAN scintigraphy showed abnormalities in 7 of 11 patients (64%) and found 12 of 22 clinical lesions (55%). False-positive 111 In-DOTA-LAN scan results were found in two patients. For supra-diaphragmatic lesions, 67 Ga scintigraphy detected 12 of 16 sites (75%). 111 In-DOTA-TOCT scintigraphy revealed 7 of 15 lesions (47%). 111 In-DOTA-LAN showed 6 of 12 positive sites (50%). For infra-diaphragmatic involvement, the sensitivities of 67 Ga, 111 In

  3. Determination of cytotoxicity in vivo using 111Indium-labelled human tumor cells

    International Nuclear Information System (INIS)

    Lockshin, Arnold; Giovanella, B.C.; Kolielski, Tony; Stehlin, J.S. Jr.

    1984-01-01

    Loss of radioactivity from nude mice was determined after inoculation of human tumor cells prelabelled with ( 111 In)indium oxine ( 111 InOx). Elimination of 111 In was increased somewhat by treating the mice with diphtheria toxin (DT), which is toxic selectively for human cells compared to mice. Calcium disodium edetate (CaNa 2 EDTA), a metal chelating agent, facilitated elimination of 111 In and increased the difference in the rates of loss of radioactivity from mice bearing viable compared to DT-killed cells. (author)

  4. 46 CFR 111.105-1 - Applicability; definition.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Applicability; definition. 111.105-1 Section 111.105-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-1 Applicability; definition. This subpart applies to...

  5. 46 CFR 111.95-3 - General requirements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General requirements. 111.95-3 Section 111.95-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Electric Power-Operated Boat Winches § 111.95-3 General requirements. (a) Each electrical...

  6. 46 CFR 111.50-2 - Systems integration.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Systems integration. 111.50-2 Section 111.50-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-2 Systems integration. The electrical characteristics of each...

  7. 48 CFR 849.111-70 - Required review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Required review. 849.111... MANAGEMENT TERMINATION OF CONTRACTS General Principles 849.111-70 Required review. (a) FAR 49.111 requires each agency to establish procedures, when necessary, for the administrative review of proposed...

  8. First-Principles Studies of Functionalized Si(111) in Air and in Water

    Science.gov (United States)

    Li, Yan; Galli, Giulia

    2011-03-01

    We have investigated structural, electronic and vibrational properties of hydrogen and methyl-terminated Si(111) surfaces both in air and in contact with water, by combining density functional theory and many-body perturbation theory within the GW approximations. The computed surface dipole moments for both H-Si(111) and CH3-Si(111) surfaces were found to be consistent with measured electron affinities (EAs), and can be explain by simple electronegative trends. While GW self-energy corrections greatly improve the absolute values of EAs, the EA difference of the two surfaces remains overestimated by about 0.3 eV. The variations in CH3 frequencies, e.g. the umbrella mode and CH stretching mode, for the surface in air and water are also well reproduced by our calculations. The influence exerted by the adsorption of water molecules on the hydrophobic H-Si(111) and CH3-(111) surfaces, in particular, on the EAs and the surface vibrational frequencies will be discussed and compared with recent experiments. This work was funded by NSF under Grant No. CHE-0802907.

  9. Monitoring of cardiac antirejection therapy with 111In lymphocytes

    International Nuclear Information System (INIS)

    Lerch, R.A.; Bergmann, S.R.; Carlson, E.M.; Saffitz, J.E.; Sobel, B.E.

    1982-01-01

    To determine whether lymphocytes labeled with 111 In permit noninvasive assessment of antirejection therapy, we performed 40 allogeneic heterotopic cardiac transplants in rats. Antirejection therapy with azathioprine (30 mg/kg) and sodium salicylate (200 mg/kg) prolonged contractile function of the graft from 7.5 +/- 1.5 (s.d.) days in controls to 19.4 +/- 3.7 days in treated animals. Six to seven days after transplantation, autologous lymphocytes labeled with 111 In were injected intravenously in seven untreated and eight treated rats. Scintigraphy and organ counting were performed 24 hr after administration of labeled cells. At sacrifice all grafts in untreated rats exhibited contractile failure, whereas grafts in all treated rats were beating well. Transplants in untreated recipients exhibited marked accumulation of 111 In lymphocytes detectable scintigraphically, with ratios of 7.7 +/- 1.9 for the activity in the transplant over that in the native heart (HT/HO), as obtained by well counting. In contrast, accumulation was not scintigraphically detectable in transplants of treated rats, with HT/HO ratios of 2.6 +/- 1.8 (p less than 0.005). The results suggested that imaging with 111 In-labeled lymphocytes will permit noninvasive assessment of antirejection therapy

  10. 46 CFR 111.107-1 - Industrial systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial systems. 111.107-1 Section 111.107-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Industrial Systems § 111.107-1 Industrial systems. (a) For the purpose of this subpart, an...

  11. 46 CFR 111.54-3 - Remote control.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Remote control. 111.54-3 Section 111.54-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Circuit Breakers § 111.54-3 Remote control. Remotely controlled circuit breakers must have local...

  12. Synergetic effects in CO adsorption on Cu-Pd(111) alloys

    DEFF Research Database (Denmark)

    Lopez, Nuria; Nørskov, Jens Kehlet

    2001-01-01

    We present density functional calculations for the interaction of CO on different Cu-Pd(111) bulk and surface alloys. The modification of the adsorption properties with respect to hose of the adsorption on pure Cu(111) and Pd(111) is described in terms of changes in the adsorption sites...... and the change of the electronic structure occurring upon alloying. The presence of cooperative, synergetic. effects is found to be important specially for Cu-rich bulk alloys. In this case. a larger adsorption energy is found for the inactive component than for the pure inactive system. This activation induces...

  13. 19 CFR 111.31 - Conflict of interest.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Conflict of interest. 111.31 Section 111.31 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.31 Conflict of interest. (a...

  14. The search for an 111In labeled agent for the solid component of gastric emptying

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Brown, M.L.; Chowdhury, S.; Thomforde, G.; Malagelada, J.

    1988-01-01

    111 In-labeled solid meal was prepared by chelation of 111 In with Chelex resin bead. The effect of grinding of normal Chelex bead on 111 In chelation and retention in solid meal was evaluated in an in vitro system. The Chelex resin beads were ground in a mortar-pestle to form ground Chelex resin beads. Fine particles were removed by resuspension in distilled water and centrifugation. One hundred to 150 μCi of 111 In chloride was diluted with HCl and mixed with 1g of Chelex resin beads. Unbound 111 In was removed by centrifugation. The 111 In-labeled Chelex resin beads were mixed with fresh egg and 111 In-labeled solid metal was prepared by heating until solid. The meals were digested with HCl-pepsin for 4 h in a stirrer-bath (37 0 C). Aliquots were collected at intervals for determination of 111 In loss from 111 In-labeled solid meal. These results suggest that 111 In Chelex resin beads were retained in solid meals at a higher level than normal Chelex resin beads and other 111 In-tracers. (author)

  15. Search for an /sup 111/In labeled agent for the solid component of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.; Brown, M.L.; Chowdhury, S.; Thomforde, G.; Malagelada, J.

    1988-01-01

    /sup 111/In-labeled solid meal was prepared by chelation of /sup 111/In with Chelex resin bead. The effect of grinding of normal Chelex bead on /sup 111/In chelation and retention in solid meal was evaluated in an in vitro system. The Chelex resin beads were ground in a mortar-pestle to form ground Chelex resin beads. Fine particles were removed by resuspension in distilled water and centrifugation. One hundred to 150 ..mu..Ci of /sup 111/In chloride was diluted with HCl and mixed with 1g of Chelex resin beads. Unbound /sup 111/In was removed by centrifugation. The /sup 111/In-labeled Chelex resin beads were mixed with fresh egg and /sup 111/In-labeled solid metal was prepared by heating until solid. The meals were digested with HCl-pepsin for 4 h in a stirrer-bath (37/sup 0/C). Aliquots were collected at intervals for determination of /sup 111/In loss from /sup 111/In-labeled solid meal. These results suggest that /sup 111/In Chelex resin beads were retained in solid meals at a higher level than normal Chelex resin beads and other /sup 111/In-tracers.

  16. /sup 111/In autologous leucocytes in the diagnosis and assessment of inflammatory bowel disease. [Tropolone

    Energy Technology Data Exchange (ETDEWEB)

    Saverymuttu, S.H.; Peters, A.M.; Chadwick, V.S.; Hodgson, H.J.; Lavender, J.P. (Hammersmith Hospital, London (UK))

    1982-01-01

    Indium-111 autologous leukocyte scanning is now established as an effective method of localising sepsis (Ascher and others, 1980). In view of the extensive leucocyte infiltration of the intestinal wall in inflammatory bowel disease, the authors have prospectively studied the use of indium-111 labelled white cells in a variety of inflammatory bowel disorders. Leukocytes were labelled in 68 patients using /sup 111/In acetylacetonate and in 18 patients /sup 111/In tropolone. Crude mixed leukocytes preparations were used in 74 patients and pure neutrophil preparation used in 12 patients. Gamma scans over the abdomen were performed from 40 min later after re-injection of the labelled cells and assessed. /sup 111/In-tropolone labelling appeared to offer the advantage over /sup 111/In-acac labelling in localising inflamed bowel earlier. The technique of /sup 111/In-leukocyte scanning offers several advantages over the alternative technique of imaging diseased bowel using gallium-67 citrate. Indium-111 leukocyte scanning provides a novel approach to the problem of diagnosis and assessment of inflammatory bowel disease. It is non-invasive, requires no bowel preparation and this is safe in the acutely sick patient where conventional radiological imaging methods may be hazardous. /sup 111/In faecal excretion provides an objective assessment of disease activity which should prove useful in evaluating treatment regimes.

  17. 19 CFR 111.39 - Advice to client.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Advice to client. 111.39 Section 111.39 Customs... CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.39 Advice to client. (a) Withheld or false information. A broker must not withhold information relative to any customs business from a client...

  18. 46 CFR 111.25-15 - Duty cycle.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Duty cycle. 111.25-15 Section 111.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motors § 111.25-15 Duty cycle. Each motor must be rated for continuous duty, except a motor for an...

  19. 46 CFR 111.05-11 - Hull return.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hull return. 111.05-11 Section 111.05-11 Shipping COAST... REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-11 Hull return. (a) A vessel's hull must not carry current as a conductor except for the following systems: (1) Impressed current...

  20. 46 CFR 111.12-9 - Generator cables.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Generator cables. 111.12-9 Section 111.12-9 Shipping... REQUIREMENTS Generator Construction and Circuits § 111.12-9 Generator cables. (a) The current-carrying capacity of generator cables must not be: (1) Less than 115 percent of the continuous generator rating; or (2...

  1. 7 CFR 735.111 - Fair treatment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Fair treatment. 735.111 Section 735.111 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE... treatment. (a) Contingent upon the capacity of a warehouse, a warehouse operator will deal in a fair and...

  2. 48 CFR 53.111 - Contract clause.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Contract clause. 53.111... AND FORMS FORMS General 53.111 Contract clause. Contracting officers shall insert the clause at 52.253-1, Computer Generated Forms, in solicitations and contracts that require the contractor to submit...

  3. Indium-111 tropolone, a new tracer for platelet labeling

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Rao, S.A.; Rosemark, J.A.; Chowdhury, S.; Didisheim, P.

    1982-01-01

    Platelets have been labeled with a new neutral, lipid-soluble metal complex of indium 111 ( 111 In) and tropolone. Unlike oxine, which is soluble in ethyl alcohol, tropolone is soluble in isotonic saline. Platelet labeling with 111 In tropolone can be performed in both acid-citrate-dextrose (ACD) plasma and ACD saline within two hours. Labeling efficiency has been 80% to 90%. 111 In tropolone in ACD saline and ACD plasma at tropolone concentrations of 5 and 10 micrograms/ml, respectively, and incubation of the platelets with the tracer at room temperature for 20 minutes were optimal conditions for labeling. The authors have developed an ACD-saline kit for convenient preparation of 111 In-labeled platelets. No adverse effect of 111 In tropolone on platelets has been observed in studies of biodistribution, recovery, and survival of platelets in rabbits and dogs

  4. Indium-111 tropolone, a new tracer for platelet labeling

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Rao, S.A.; Rosemark, J.A.; Chowdhury, S.; Didisheim, P.

    1982-01-01

    Platelets have been labeled with a new neutral, lipid-soluble metal complex of indium 111 ( 111 In) and tropolone. Unlike oxine, which is soluble in ethyl alcohol, tropolone is soluble in isotonic saline. Platelet labeling with 111 In tropolone can be performed in both acid-citrate-dextrose (ACD) plasma and ACD saline within two hours. Labeling efficiency has been 80% to 90%. 111 In tropolone in ACD saline and ACD plasma at tropolone concentrations of 5 to 10 μg/ml, respectively, and incubation of the platelets with the tracer at room temperature for 20 minutes were optimal conditions for labeling. The authors have developed an ACD-saline kit for convenient preparation of 111 In-labeled platelets. No adverse effect of 111 In tropolone on platelets has been observed in studies of biodistribution, recovery, and survival of platelets in rabbits and dogs

  5. 19 CFR 111.29 - Diligence in correspondence and paying monies.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Diligence in correspondence and paying monies. 111...; DEPARTMENT OF THE TREASURY CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.29 Diligence in correspondence and paying monies. (a) Due diligence by broker. Each broker must exercise due...

  6. Carbon monoxide oxidation on bimetallic Ru/Au(111 surfaces

    Directory of Open Access Journals (Sweden)

    ROLF-JÜRGEN BEHM

    2001-02-01

    Full Text Available The electrochemical deposition of Ru on Au(111 was performed in 0.5 M H2SO4+10-4 M RuCl3 . The obtained bimetallic Ru/Au(111 surfaces were character-ised by cyclic voltammetry and in situ STM in 0.5 MH2SO4. The Ru deposit consists of nanoscale islands, which merge with increasing coverage. Two different types of bimetallic Ru/Au(111 surfaces with respect to the distribution of Ru islands over the Au(111 substrate surface were obtained. When the deposition was performed at potentials more positive than the range of Au(111 reconstruction, homogeneous nucleation occured resulting in a random distribution of Ru islands. When the deposition was performed on reconstructed Au(111 at low overpotentials, selective nucleation occured resulting in the replication of the Au(111 reconstruction. Only at higher deposition overpotentials, can multilayer deposits be formed, which exhibit a very rough surface morphology. The electrocatalytic activity of such structurally well defined Ru/Au(111 bimetallic surfaces was studied towards CO oxidation with the Ru coverage ranging from submonolayer to several monolayer. COstripping commences at about 0.2 Vand occurs over a broad potential range. The observed influence of the Ru structure on the CO stripping voltammetry is explained by local variations in the COadsorption energy, caused by differences in the local Ru structure and by effects induced by the Au(111 substrate.

  7. 34 CFR 300.111 - Child find.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Child find. 300.111 Section 300.111 Education... REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION ASSISTANCE TO STATES FOR THE EDUCATION OF CHILDREN WITH... child with a disability under § 300.8 and in need of special education, even though they are advancing...

  8. Communication: Surface-to-bulk diffusion of isolated versus interacting C atoms in Ni(111) and Cu(111) substrates: A first principle investigation

    Energy Technology Data Exchange (ETDEWEB)

    Harpale, Abhilash; Panesi, Marco; Chew, Huck Beng, E-mail: hbchew@illinois.edu [Department of Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)

    2015-02-14

    Using first principle calculations, we study the surface-to-bulk diffusion of C atoms in Ni(111) and Cu(111) substrates, and compare the barrier energies associated with the diffusion of an isolated C atom versus multiple interacting C atoms. We find that the preferential Ni-C bonding over C–C bonding induces a repulsive interaction between C atoms located at diagonal octahedral voids in Ni substrates. This C–C interaction accelerates C atom diffusion in Ni with a reduced barrier energy of ∼1 eV, compared to ∼1.4-1.6 eV for the diffusion of isolated C atoms. The diffusion barrier energy of isolated C atoms in Cu is lower than in Ni. However, bulk diffusion of interacting C atoms in Cu is not possible due to the preferential C–C bonding over C–Cu bonding, which results in C–C dimer pair formation near the surface. The dramatically different C–C interaction effects within the different substrates explain the contrasting growth mechanisms of graphene on Ni(111) and Cu(111) during chemical vapor deposition.

  9. Communication: Surface-to-bulk diffusion of isolated versus interacting C atoms in Ni(111) and Cu(111) substrates: A first principle investigation.

    Science.gov (United States)

    Harpale, Abhilash; Panesi, Marco; Chew, Huck Beng

    2015-02-14

    Using first principle calculations, we study the surface-to-bulk diffusion of C atoms in Ni(111) and Cu(111) substrates, and compare the barrier energies associated with the diffusion of an isolated C atom versus multiple interacting C atoms. We find that the preferential Ni-C bonding over C-C bonding induces a repulsive interaction between C atoms located at diagonal octahedral voids in Ni substrates. This C-C interaction accelerates C atom diffusion in Ni with a reduced barrier energy of ∼1 eV, compared to ∼1.4-1.6 eV for the diffusion of isolated C atoms. The diffusion barrier energy of isolated C atoms in Cu is lower than in Ni. However, bulk diffusion of interacting C atoms in Cu is not possible due to the preferential C-C bonding over C-Cu bonding, which results in C-C dimer pair formation near the surface. The dramatically different C-C interaction effects within the different substrates explain the contrasting growth mechanisms of graphene on Ni(111) and Cu(111) during chemical vapor deposition.

  10. Detection of intrathoracic infectious lesions using {sup 111}In-diethylenetriamine pentaacetic bicyclic anhydride-IgG ({sup 111}In-DTPA-IgG) scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Tomohiro; Goto, Hajime; Wada, Hiroo; Yuasa, Kazumi; Iguchi, Mari; Okamura, Tatsuru; Ieki, Ryuji; Suzuki, Kenzo [Tokyo Metropolitan Komagome General Hospital (Japan)

    1998-02-01

    The utility of {sup 111}In-DTPA-IgG imaging for the detection of intrathoracic lesions was evaluated in 10 patients with the suspicion of inflammatory or infectious diseases. They were intravenously administered 40 or 80 MBq of {sup 111}In-DTPA-IgG, and scanned after 24 or 48 hours. Of these, 8 cases, consisted of 4 cases with pneumonia and 2 cases with lung abscess and one case of pulmonary tuberculosis and one of a tuberculous pleuritis, showed true positive results. Others were one false negative case of pneumonia and one true negative case of lung cancer. Overall sensitivity and specificity were 88.9% and 100%, respectively. There were no cases which showed side effects or abnormal laboratory findings caused by the radiopharmaceuticals administered. Thus, {sup 111}In-DTPA-IgG imaging is a useful tool for the detection of intrathoracic infectious lesions. (author)

  11. 111In-pentetreotide therapy in patients with inoperable benign intracranial tumors

    International Nuclear Information System (INIS)

    Minutoli, F.; Sindoni, A.; Cardile, D.; Amato, E.; Cassalia, L.; Herberg, A.; Baldari, S.

    2015-01-01

    Full text of publication follows. Aim: in the last years Peptide Receptor Radionuclide Therapy (PRRT) acquired greater importance as an alternative or complementary treatment of neuroendocrine tumors (NETs) and other somatostatin receptor positive (sstr+) tumors. Many studies about PRRT using different radiopharmaceuticals, mainly 90 Y and 177 Lu (beta-emitters) labelled peptides, are reported in the literature. 177 Lu-labeled somatostatin analogues seem to be more effective because of their favourable physical properties and the better objective response. On the other hand, only few reports exist on PRRT using 111 In-Pentetreotide, an Auger-emitter. The aim of this study is to evaluate the usefulness of 111 In-Pentetreotide therapy in patients with sstr+ inoperable benign intracranial tumors in which the use of beta-emitters radiopharmaceuticals (characterized by higher penetration range) could be unsafe and questionable since lesions were close to critical anatomical structures, such as optic chiasm or medulla oblongata. Materials and methods: we retrospectively reviewed clinical records of 9 patients (7 Females and 2 Males) affected by sstr+ benign intracranial tumors (mean age: 58.4 years, range 50-81): 8 patients had meningiomas/meningiomatosis and 1 patient had a pituitary macroadenomas. A previous diagnostic scintigraphy with 111 In-Pentetreotide demonstrated high intralesional radiotracer uptake. All patients underwent PRRT with high therapeutic activities of 111 In-Pentetreotide (1-7 cycles, median 4 cycles, activity per cycle 3.7-7.5 GBq, median activity per cycle 7 GBq, cumulative activity range 13.7-66 GBq). Efficacy of PRRT was evaluated according to RECIST criteria. Toxicity was also assessed considering hematological parameters and GFR value estimated by renal dynamic scintigraphy. Results: no patient had acute damage. Complete response was observed in 1 patient (11.1%). Partial response was observed in 2 patients (22.2%); stable disease was observed

  12. Lymphocyte targeting with /sup 111/In-labelled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Loutfi, I.; Batchelor, J.R.; Lavender, J.P.; Epenetos, A.A.

    1988-01-01

    In vitro tests were conducted using human T and B cell lines, as well as whole blood, to establish the usefulness of 2 murine monoclonal antibodies (MAbs), an anti-CD5 (Pan T) and a Pan B, for potential radioimmunolocalization and therapy. Both MAbs showed specificity for the cell line in question as tested by indirect immunofluorescence and radioimmunoassay. Assays carried out on whole blood showed 40-70% of the added activity of /sup 111/In-labelled Pan B antibody binding to B cells and 20-24% of /sup 111/In-Pan T antibody binding to T cells. The amount of internalised /sup 111/In-labelled Pan B was 6% of total amount at 24 hr indicating a slow internalization process. These results should allow for in vivo targeting of normal and neoplastic B and T cells.

  13. 46 CFR 111.30-19 - Buses and wiring.

    Science.gov (United States)

    2010-10-01

    ... control wiring must be— (1) Suitable for installation within in a switchboard enclosure and be rated at 90... 46 Shipping 4 2010-10-01 2010-10-01 false Buses and wiring. 111.30-19 Section 111.30-19 Shipping... REQUIREMENTS Switchboards § 111.30-19 Buses and wiring. (a) General. Each bus must meet the requirements of...

  14. Adverse reactions (aseptic meningitis) from 111In--DTPA cisternographic examinations

    International Nuclear Information System (INIS)

    Jayabalan, V.; White, D.; Bank, M.

    1975-01-01

    Cisternographic examinations have become a relatively common procedure in the evaluation of patients with suspected communicating hydrocephalus. Adverse reactions to radiopharmaceuticals are relatively uncommon, particularly with the commonly used agents such as 111 In-DTPA and 169 -DTPA. Adverse reactions after lumbar intrathecal instillation of 111 In-DTPA in three patients are described. (U.S.)

  15. Animal experiment of 111In-DTPA-D-Phe1-octreotide

    International Nuclear Information System (INIS)

    Wang Fan; Xiao Lun; Fan Hongqiang; Jin Xiaohai; Wang Yishan; Chen Daming; Bai Hongsheng; Chen Fang; Li Jiaxiu; Liu Lin

    1998-01-01

    The animal experiments of a novel somatostatin receptor-positive tumors imaging agent, 111 In-DTPA-D-Phe 1 -octreotide, has been described. Biological properties were evaluated by dynamic and static γ images of somatostatin receptor-positive tumors in nude mice bearing pancreatic carcinoma. The radiocomponent of 111 In-DTPA, which came from 111 In-DTPA-D-Phe 1 -octreotide decomposition, showed 50% of radioactivity in blood and 40% in urine at 3h postinjection. Rapid blood and urine clearance, and high T/B ratio (7.92 up to 24 h postinjection) were observed. The images of somatostatin receptor-positive tumors could be obtained during 0.5-24 h after administration but the best one would be at 24 h

  16. Radiolabeled, nonspecific, polyclonal human immunoglobulin in the detection of focal inflammation by scintigraphy: Comparison with gallium-67 citrate and technetium-99m-labeled albumin

    International Nuclear Information System (INIS)

    Rubin, R.H.; Fischman, A.J.; Needleman, M.; Wilkinson, R.; Callahan, R.J.; Khaw, B.A.; Hansen, W.P.; Kramer, P.B.; Strauss, H.W.

    1989-01-01

    The accumulation of nonspecific polyclonal human immunoglobulin (IgG) radiolabeled with 125 I or 111 In was compared to that of [ 67 Ga]citrate and [ 99m Tc]albumin in rats with deep thigh inflammation due to Escherichia coli infection. Serial scintigrams were acquired at 1, 3, 24, and in some cases, 48 hr after injection. As early as 3 hr postinjection, [ 111 In]IgG showed greater accumulation at the lesion than [ 99m Tc]HSA (p less than 0.01). Both [ 125 I]IgG and [ 111 In]IgG showed greater accumulation than [ 67 Ga]citrate (p less than 0.01). At 24 hr, IgG image definition increased, while HSA image definition decreased, and the intensity of accumulation of both IgG preparations was greater than that of [ 67 Ga]citrate or [ 99m Tc]HSA (p less than 0.01). At all imaging times, [ 67 Ga]citrate accumulation was surprisingly low. In inflammation produced by Pseudomonas aeruginosa, Staphylococcus aureus, Klebsiella pneumoniae, Candida albicans, or turpentine, [ 111 In]IgG accumulation was similar to the results obtained with Escherichia coli. These studies suggest that focal sites of inflammation can be detected with radiolabeled nonspecific human polyclonal IgG

  17. Value of {sup 111}In-DOTA-lanreotide and {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide in differentiated thyroid cancer: results of in vitro binding studies and in vivo comparison with {sup 18}F-FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Margarida; Virgolini, Irene [Lainz Hospital, Institute of Nuclear Medicine, Vienna (Austria); University Clinic for Nuclear Medicine, Innsbruck (Austria); Traub-Weidinger, Tatjana [University Clinic for Nuclear Medicine, Innsbruck (Austria); University Hospital, Department of Nuclear Medicine, Vienna (Austria); Leimer, Maria; Li, Shuren; Dudczak, Robert [University Hospital, Department of Nuclear Medicine, Vienna (Austria); Andreae, Fritz [University Clinic for Nuclear Medicine, Innsbruck (Austria); Angelberger, Peter [Austrian Research Center, Department of Radiochemistry, Seibersdorf (Austria)

    2005-10-01

    Radioiodine-negative thyroid cancer presents diagnostic and therapeutic difficulties, warranting the implementation of new imaging and treatment strategies. The purpose of this study was twofold. First, we investigated in vitro the binding characteristics of {sup 111}In-DOTA-lanreotide ({sup 111}In-DOTA-LAN) and {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide ({sup 111}In-DOTA-TOC) to cells derived from differentiated thyroid cancer (DTC). Second, we evaluated the value of somatostatin receptor (SSTR) scintigraphy with these radioligands, as compared with {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET), for the detection of tumour lesions in DTC patients. Binding of {sup 111}In-DOTA-LAN and {sup 111}In-DOTA-TOC to cells isolated from surgically removed thyroid tissue was evaluated in vitro by performing saturation and displacement studies. Eighteen DTC patients with elevated thyroglobulin (12 radioiodine-negative, six radioiodine-positive) were investigated with {sup 111}In-DOTA-LAN, {sup 111}In-DOTA-TOC and {sup 18}F-FDG PET scans. Large numbers of SSTR binding sites for {sup 111}In-DOTA-LAN and {sup 111}In-DOTA-TOC were found on the cells investigated. Both SSTR radioligands exhibited a high binding affinity for these SSTR binding sites. {sup 111}In-DOTA-LAN and {sup 111}In-DOTA-TOC scintigraphy detected 37 and 33 lesions, respectively, in 17 (94%) patients each, whereas {sup 18}F-FDG PET revealed 30 lesions in 15 (83%) patients. Uptake of both SSTR radioligands was found in several radioiodine-negative sites. No striking differences in lesion imaging by {sup 111}In-DOTA-LAN and {sup 111}In-DOTA-TOC were found. In both radioiodine-negative and radioiodine-positive patients, more lesions were SSTR-positive/{sup 18}F-FDG-negative than were {sup 18}F-FDG-positive/SSTR-negative. Adding a SSTR scan with these radioligands to the diagnostic work-up increases the diagnostic capacity in DTC, and should be considered particularly in radioiodine

  18. Correlation between radioactivity and chemotherapeutics of the 111In-VNB-liposome in pharmacokinetics and biodistribution in rats

    Directory of Open Access Journals (Sweden)

    Tsai TH

    2012-02-01

    Full Text Available Wen-Chuan Lee1,*, Chih-Hsien Chang2,3,*, Chih-Min Huang1, Yu-Tse Wu1, Liang-Cheng Chen2, Chung-Li Ho2, Tsui-Jung Chang2, Te-Wei Lee2, Tung-Hu Tsai1,41Institute of Traditional Medicine, School of Medicine, National Yang-Ming University, Taipei, 2Division of Isotope Application, Institute of Nuclear Energy Research, Taoyuan, 3Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 4Department of Education and Research, Taipei City Hospital, Taipei, Taiwan*These authors contributed equally to this workBackground: The combination of a radioisotope with a chemotherapeutic agent in a liposomal carrier (ie, Indium-111-labeled polyethylene glycol pegylated liposomal vinorelbine, [111In-VNB-liposome] has been reported to show better therapeutic efficiency in tumor growth suppression. Nevertheless, the challenge remains as to whether this therapeutic effect is attributable to the combination of a radioisotope with chemotherapeutics. The goal of this study was to investigate the pharmacokinetics, biodistribution, and correlation of Indium-111 radioactivity and vinorelbine concentration in the 111In-VNB-liposome.Methods: The VNB-liposome and 111In-VNB-liposome were administered to rats. Blood, liver, and spleen tissue were collected to determine the distribution profile of the 111In-VNB-liposome. A liquid chromatography tandem mass spectrometry system and gamma counter were used to analyze the concentration of vinorelbine and radioactivity of Indium-111.Results: High uptake of the 111In-VNB-liposome in the liver and spleen demonstrated the properties of a nanosized drug delivery system. Linear regression showed a good correlation (r = 0.97 between Indium-111 radioactivity and vinorelbine concentration in the plasma of rats administered the 111In-VNB-liposome.Conclusion: A significant positive correlation between the pharmacokinetics and biodistribution of 111Indium radioactivity and vinorelbine in blood, spleen

  19. Implantation of 111In in NTDSi by heavy ion recoil technique

    International Nuclear Information System (INIS)

    Thakare, S.V.; Tomar, B.S.

    1998-01-01

    Heavy ion recoil implantation technique has been used to implant 111 In in n-type silicon using medium energy heavy ion accelerator Pelletron, at TIFR, Colaba, Mumbai. The nuclear reaction used for this purpose was 109 Ag( 7 Li,p4n) 111 In. The beam energy was optimised to be 50 MeV for maximum concentration of the implanted probe atoms. The gamma-ray spectrum of the implanted sample after 24 hours was found to contain only 171 and 245 keV gamma rays of 111 In. The penetration depth of ion is increased to 1.6 μm by heavy ion recoil implantation technique as compared to 0.16 μm with the conventional ion implantation technique. (author)

  20. Imaging experimental coronary artery thrombosis with indium-111 platelets

    International Nuclear Information System (INIS)

    Riba, A.L.; Thakur, M.L.; Gottschalk, A.; Zaret, B.L.

    1979-01-01

    The ability of cardiac scintigraphy with indium-111 ( 111 In)-labeled platelets to detect coronary artery thrombosis (CAT) was assessed in a canine model. Cardiac imaging and tissue distribution studies were performed shortly after administering 111 In-labeled platelets to 12 dogs (group 1) with acute CAT. Four dogs (group 2) with acute CAT were studied 2 and 22 hours after administering 111 In platelets. In addition, four dogs (group 3) with 24-hour-old CAT were similarly evaluated. In all group 1 animals, in vivo imaging 1 to 2 hours after 111 In platelet administration revealed intense uptake in the region of thrombus-containing left anterior descending arteries that was readily discernible from background blood pool activity. Sequential imaging of the four group 2 animals over a 22-hour period revealed no change in the scintigraphic pattern of the thrombosed arteries. In contrast, 111 In platelet imaging in the four group 3 animals with 24-hour-old CAT failed to reveal enhanced activity within the region of the thrombus-containing coronary artery. In the 12 group 1 animals, the CAT accumulated 69 +- 10 (mean +- SEM) times greater activity than present in blood and 651 +- 135 times greater activity than normal left ventricular myocardium. There was 24 +- 7 times greater 111 In activity in the damaged left anterior descending arteries compared with normal circumflex arteries. Similar uptake ratios were seen in group 2 animals. The 24-hour old thrombi from group 3 animals showed no enhanced 111 In uptake. This study demonstrates that experimental acute CAT can be detected readily with 111 In platelet cardiac scintigraphy

  1. Pharmacokinetics of indium-111-labeled antimyosin monoclonal antibody in murine experimental viral myocarditis

    International Nuclear Information System (INIS)

    Yamada, T.; Matsumori, A.; Watanabe, Y.; Tamaki, N.; Yonekura, Y.; Endo, K.; Konishi, J.; Kawai, C.

    1990-01-01

    The pharmacokinetics of indium-111-labeled antimyosin monoclonal antibody Fab were investigated with use of murine experimental viral myocarditis as a model. The biodistribution of indium-111-labeled antimyosin antibody Fab on days 3, 5, 7, 14, 21 and 28 after encephalomyocarditis virus inoculation demonstrated that myocardial uptake increased significantly on days 5, 7 and 14 (maximum on day 7) in infected versus uninfected mice (p less than 0.001). In vivo kinetics in infected mice on day 7 demonstrated that the heart to blood ratio reached a maximum 48 h after the intravenous administration of indium-111-labeled antimyosin Fab, which was considered to be the optimal time for scintigraphy. The scintigraphic images obtained with indium-111-labeled antimyosin Fab demonstrated positive uptake in the cardiac lesion in infected mice. The pathologic study demonstrated that myocardial uptake correlated well with pathologic grades of myocardial necrosis. High performance liquid chromatography revealed the presence of an antigen-antibody complex in the circulation of infected mice after the injection of indium-111-labeled antimyosin Fab. This antigen bound to indium-111-labeled antimyosin Fab in the circulation might be whole myosin and this complex may decrease myocardial uptake and increase liver uptake. It is concluded that indium-111-labeled antimyosin monoclonal antibody Fab accumulates selectively in damaged heart tissue in mice with acute myocarditis and that indium-111-labeled antimyosin Fab scintigraphy may be a useful method for the visualization of acute myocarditis

  2. Functional alterations of human platelets following 111In labeling with different ligands and incubation media

    International Nuclear Information System (INIS)

    Mieno, Masayuki; Isaka, Yoshinori; Kimura, Kazutumi

    1990-01-01

    We studied the effects of various 111 In-water soluble chelates and incubation media on labeling efficiency of platelets and in vitro platelet aggregability. High labeling efficiency of platelets in ACD-saline was achieved with 111 In-oxine sulfate, 111 In-tropolone and 111 In-MPO (2-mercaptopyridine-N-oxide). In the condition with 4.8 x 10 6 /mm 3 platelets in ACD-plasma, 111 In-oxine-sulfate had low labeling efficiency and inconsistent labeling, while 111 In-tropolone and 111 In-MPO had high labeling efficiency. In vitro platelet aggregability (ADP 2μM) was reduced when platelets were labeled in the absence of plasma. However, there was no significant difference in platelet aggregability among 111 In-platelets labeled by three different chelates. In conclusion, to maintain aggregation activity of the platelets with relatively high labeling efficiency, the best result was obtained by using MPO or tropolone chelate in plasma at 4.8 x 10 6 /μl platelet concentration. (author)

  3. New estradiol based {sup 111}In complex towards the estrogen receptor

    Energy Technology Data Exchange (ETDEWEB)

    Vultos, Filipe; Cunha, Susana; Fernandes, Celia; Oliveira, Maria Cristina; Marques, Fernanda; Santos, Isabel; Gano, Lurdes [Universidade de Lisboa, Bobadela (Portugal). Centro de Ciencias e Tecnologias Nucleares C2TN; Botelho, Maria Filomena [Universidade de Coimbra (Portugal). Inst. de Biofisica/Biomatematica

    2015-07-01

    The oestrogen receptor (ER) is an important tumour target for molecular imaging and radionuclide therapy due to its overexpression in many malignant cells as compared to normal cells. Aiming to find new functional molecular imaging/therapeutic agents for ER positive tumours, we have synthesized a new estradiol derivative substituted at the 16-α position with a diethylene triamine tetraacetic acid (DTTA)-like chelating ligand through a four-carbon spacer. The new bioconjugate (H{sub 4}L), was used to synthesize the corresponding indium complexes (InL/[{sup 111}In]L). The radioactive complex [{sup 111}In]L was prepared in high yield (>98%) at final concentrations of 1 x 10{sup -4} M and its chemical identity was ascertained by comparing its HPLC gamma-chromatogram to the HPLC UV-vis-chromatogram of the InL analogue. [{sup 111}In]L is hydrophilic and kinetically stable in the presence of an excess of apo-transferrin and in human blood serum. Cellular studies in breast cancer cells (MCF-7 and MDA-MB-431) suggest that [{sup 111}In]L uptake may be mediated by an ER dependent mechanism. Biodistribution studies were performed in mice indicating a rapid clearance from most organs and a slow total excretion that occurs mainly by hepatobiliar pathway. High in vivo stability of [{sup 111}In]L was confirmed by HPLC analysis of urine and blood samples. Nevertheless, the hydrophilicity, the low ER affinity and the biodistribution of [{sup 111}In]L indicate that structural modifications are required to improve its behaviour for ER targeting in vivo.

  4. Diagnostic value of female genital malignant tumors by using 111In-bleomycin scintigraphy

    International Nuclear Information System (INIS)

    Kida, Toshiyuki; Ikeda, Masanori; Saito, Masaru

    1978-01-01

    In order to know if it is possible to objectively decide the extent of infiltration of female genital malignant tumors into parametrium by using 111 In-bleomycin scintigraphy, a fundamental and clinical investigation was made. The radiochemical purity and stability of 111 In-BLM were comparatively unchangeable. When this complex was kept at room temperature for a week, there was not more than 2% of the free 111 In. As to blood clearance, when the blood radioactivity of 111 In-BLM 5 minutes after the injection was counted as 100%, about 80% of the radioactivity was cleared from the blood in 48 hours. Over 50% of the radioactivity was excreted into the urine in 48 hours. Of 29 cases of female genital malignant tumors, 23 cases (79%) showed positive images. Therefore 111 In-BLM was found to be one of the suitable radiopharmaceuticals for the diagnosis of female genital malignant tumors. 111 In-BLM scintigraphy was of great use for deciding the extent of the invasion of carcinoma cervicis uteri into parametrium and for the search of metastasis. (author)

  5. 40 CFR 432.111 - Special definitions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Special definitions. 432.111 Section 432.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND... definitions. For the purpose of this subpart: Poultry first processing means slaughtering of poultry and...

  6. (111)Indium Labelling of Recombinant Activated Coagulation Factor VII

    DEFF Research Database (Denmark)

    Nalla, Amarnadh; Buch, Inge; Sigvardt, Maibritt

    2012-01-01

    The aim of this study is to investigate whether (111)Indium-labelled recombinant FVIIa (rFVIIa) could be a potential radiopharmaceutical for localization of bleeding sources. DTPA-conjugated rFVIIa was radiolabelled with (111)In chloride. In vitro binding efficiency of (111)In-DTPA-rFVIIa to F1A2...

  7. Room temperature magnetism of few-nanometers-thick Fe{sub 3}O{sub 4}(111) films on Pt(111) and Ru(0001) studied in ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, M., E-mail: lewandowski@amu.edu.pl [NanoBioMedical Centre, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Institute of Molecular Physics, Polish Academy of Sciences, M. Smoluchowskiego 17, 60-179 Poznań (Poland); Miłosz, Z.; Michalak, N.; Ranecki, R. [Institute of Molecular Physics, Polish Academy of Sciences, M. Smoluchowskiego 17, 60-179 Poznań (Poland); Sveklo, I.; Kurant, Z.; Maziewski, A. [Faculty of Physics, University of Białystok, Lipowa 41, 15-424 Białystok (Poland); Mielcarek, S. [Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Luciński, T. [Institute of Molecular Physics, Polish Academy of Sciences, M. Smoluchowskiego 17, 60-179 Poznań (Poland); Jurga, S. [NanoBioMedical Centre, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland)

    2015-09-30

    Few-nanometers-thick Fe{sub 3}O{sub 4}(111) films were epitaxially grown on Pt(111) and Ru(0001) single crystal supports by sequential iron deposition and oxidation in an ultra-high vacuum chamber. The growth of well-ordered magnetite films was confirmed by low energy electron diffraction. The films were covered with a protective Au layer and subjected to magnetic and structural studies in ambient conditions. Magnetic hysteresis loops, recorded using magneto-optical Kerr effect apparatus, confirmed magnetic ordering in both films at room temperature. The Kerr measurements indicated in-plane orientation of magnetization, which was supported by the lack of magnetic contrast in magnetic force microscopy images. Atomic force microscopy revealed significant differences in morphology of the films, tentatively attributed to different lattice mismatch with Pt(111) and Ru(0001) single crystal supports. - Highlights: • Few-nanometers-thick Fe{sub 3}O{sub 4}(111) films were grown on Pt(111) and Ru(0001). • Magnetic properties were studied using MOKE and AFM/MFM in ambient conditions. • The films exhibited in-plane magnetic ordering at room temperature. • Differences in magnetic properties were tentatively assigned to structural differences.

  8. 111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection

    International Nuclear Information System (INIS)

    Rubin, R.H.; Fischman, A.J.; Callahan, R.J.; Khaw, B.A.; Keech, F.; Ahmad, M.; Wilkinson, R.; Strauss, H.W.

    1989-01-01

    We performed radionuclide scanning after the intravenous injection of human IgG labeled with indium-111 in 128 patients with suspected focal sites of inflammation. Localization of 111In-labeled IgG correlated with clinical findings in 51 infected patients (21 with abdominal or pelvic infections, 11 with intravascular infections, 7 with pulmonary infections, and 12 with skeletal infections). Infecting organisms included gram-positive bacteria, gram-negative bacteria, Pneumocystis carinii, Mycoplasma pneumoniae, and Candida albicans. No focal localization of 111In-labeled IgG was observed in 63 patients without infection. There were five false negative results, and nine results were unusable. Serial scans were carried out in eight patients: continued localization correctly predicted relapse in six, and the absence of localization indicated resolution in two. To determine whether 111In-labeled IgG localization was specific for inflammation, we studied 16 patients with cancer. Focal localization occurred in 13 of these patients (5 with melanomas, 5 with gynecologic cancers, and 1 each with lymphoma, prostate cancer, and malignant fibrous histiocytoma). No localization was seen in patients with renal or colon cancer or metastatic medullary carcinoma of the thyroid. We conclude that 111In-labeled IgG imaging is effective for the detection of focal infection and that serial scans may be useful in assessing therapeutic efficacy. This technique may also be helpful in the evaluation of certain cancers

  9. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  10. Theoretical study of PTCDA adsorbed on the coinage metal surfaces, Ag(111), Au(111) and Cu(111)

    International Nuclear Information System (INIS)

    Romaner, L; Nabok, D; Puschnig, P; Ambrosch-Draxl, C; Zojer, E

    2009-01-01

    A thorough understanding of the adsorption of molecules on metallic surfaces is a crucial prerequisite for the development and improvement of functionalized materials. A prominent representative within the class of π-conjugated molecules is 3,4,9,10-perylene-tetracarboxylic acid dianhydride (PTCDA) which, adsorbed on the Ag(111), Au(111) or Cu(111) surfaces, shows characteristic trends for work-function modification, alignment of molecular levels with the substrate Fermi energy and binding distances. We carried out density functional theory (DFT) calculations to investigate to what extent these trends can be rationalized on a theoretical basis. We used different density functionals (DF) including a fully non-local van der Waals (vdW) DF capable of describing dispersion interactions. We show that, rather independent of the DF, the calculations yield level alignments and work-function modifications consistent with ultra-violet photoelectron spectroscopy when the monolayer is placed onto the surfaces at the experimental distances (as determined from x-ray standing wave experiments). The lowest unoccupied molecular orbital is occupied on the Ag and Cu surfaces, whereas it remains unoccupied on the Au surface. Simultaneously, the work function increases for Ag but decreases for Cu and Au. Adsorption distances and energies, on the other hand, depend very sensitively on the choice of the DF. While calculations in the local density approximation bind the monolayer consistently with the experimental trends, the generalized gradient approximation in several flavors fails to reproduce realistic distances and energies. Calculations employing the vdW-DF reveal that substantial bonding contributions arise from dispersive interactions. They yield reasonable binding energies but larger binding distances than the experiments.

  11. Plutonium-238 dioxide/T-111 compatibility studies

    International Nuclear Information System (INIS)

    Jones, G.J.; Selle, J.E.; Teaney, P.E.

    1975-01-01

    The tantalum-base alloy, T-111, is an ideal radioisotope encapsulant from the aspect of mechanical properties, but unfortunately undergoes severe oxygen embrittlement during long-term, high-temperature exposure to PuO 2 . A study was undertaken in an effort to improve T-111/PuO 2 compatibility by testing the hypothesis that reduction of fuel stoichiometry to the range PuO 1 . 75 to PuO 1 . 8 would suspend the embrittlement process by producing a state of thermodynamic equilibrium within the capsule. Test temperatures ranged from 773 to 1373 0 K, with aging times of 60 days, 240 days, and 2 y. The desired reaction did not proceed rapidly enough at the aging temperatures to stop T-111 embrittlement. Capsules heated above 1573 0 K for 1 hr showed no signs of embrittlement during aging, even after 2 y at temperatures as high as 1173 0 K. Results with test specimens employing pelletized fuel indicated the solid-state diffusion of oxygen from the fuel to the T-111 was the dominating transport process. In nonpretreated capsules oxygen diffusion in T-111 was the rate-controlling process. Pretreatment does result in the desired thermodynamic equilibrium at temperatures up to at least 1173 0 K. (auth)

  12. 46 CFR 111.01-11 - Corrosion-resistant parts.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Corrosion-resistant parts. 111.01-11 Section 111.01-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-11 Corrosion-resistant parts. Each enclosure and part of electric...

  13. 48 CFR 732.111 - Contract clauses.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract clauses. 732.111... CONTRACTING REQUIREMENTS CONTRACT FINANCING General 732.111 Contract clauses. (a) [Reserved] (b) USAID may... Agency-specific indefinite quantity contracts that are a combination of contract types. Rather than using...

  14. Adsorption and dehydrogenation of tetrahydroxybenzene on Cu(111)

    DEFF Research Database (Denmark)

    Bebensee, Fabian; Svane, K.; Bombis, Christian

    2013-01-01

    Adsorption of tetrahydroxybenzene (THB) on Cu(111) and Au(111) surfaces is studied using a combination of STM, XPS, and DFT. THB is deposited intact, but on Cu(111) it undergoes gradual dehydrogenation of the hydroxyl groups as a function of substrate temperature, yielding a pure dihydroxy......-benzoquinone phase at 370 K. Subtle changes to the adsorption structure upon dehydrogenation are explained from differences in molecule–surface bonding....

  15. Disintegration rate of Tc -99m and In -111 radioactive solutions in coincidence systems

    International Nuclear Information System (INIS)

    Brito, Andreia Barreto de

    2011-01-01

    The 111 In and 99 mTc standardization in a 4πβ-γ coincidence system is described. The 111 In was produced by the reaction of 111 Cd (p, n) 111 In in the cyclotron. The 111 In decays with a half life of 2.8 days by electron capture process, populating the excited levels of 111 Cd, emitting two main gamma rays with energies of 171 keV and 245 keV. The 99m Tc decay with a half life of 6.007 h for isomeric transition, from the radioactive decay of 99 Mo. 111 In standardization was carried out in a 4πβ-γ system, consisted of a gas flow proportional counter with 4π geometry coupled to a pair of NaI(Tl) scintillation counter with conventional electronics. The gamma window was set comprising the (171 keV + 245 keV) total absorption energy peaks. The choice of the window was based on the analysis of the extrapolation curves prediction, obtained by Monte Carlo simulation. The 99 mTc standardization has been accomplished by the 4πβ-γ coincidence method using a thin window proportional counter in a 4π geometry coupled to a single NaI(Tl) scintillation counter. The beta efficiency was varied by electronic discrimination using a software coincidence counting system (SCS). Two windows were selected for the gamma channel: one at 140 keV gamma ray and the other at 20 keV X ray total absorption peaks. The result of the experimental activity of 111 In two solutions agree with the results obtained by Monte Carlo simulation. The experimental activities of 99m Tc for the two gamma windows are in agreement within the experimental uncertainty, indicating that the adopted methodology is adequate. (author)

  16. The labelling of Nanocoll[reg] with [111In] for dual-isotope scanning

    International Nuclear Information System (INIS)

    Mitterhauser, Markus; Wadsak, Wolfgang; Key Mien, Leonhard-; Eidherr, Harald; Roka, Sebastian; Zettinig, Georg; Angelberger, Peter; Viernstein, Helmut; Kletter, Kurt; Dudczak, Robert

    2003-01-01

    Visualization and biopsy of sentinel lymph nodes play an important role in planning and controlling the therapy of breast cancer. Hitherto two methods--scintigraphy or gamma probe detection after injection of [ 99m Tc]-nanocolloids and visual detection after injection of patent blue dye--are used routinely. There are no conclusive publications elucidating such important parameters as injection site, injection method and colloidal parameters. The present work aims to label Nanocoll[reg] with [ 111 In] to provide an alternative method, a simultaneous one-compound dual-isotope application. Methods: [ 111 In]-Indiumchloride was buffered with acetate and transferred to the nanocolloid. The colloid labelling reaction was complete after 30 min and filtrated through 100 nm Nuclepore[reg] filters. Results: Incorporation yield of [ 111 In]-Indium into the nanocolloid was nearly quantitative, the step associated with the major loss of activity was the particle sizing with a mean yield of 55%. Conclusion: The presented method allows for the routine supply of [ 111 In]-nanocolloids. Size-filtered [ 111 In]-Nanocoll[reg] shows the same particle size range as [ 99m Tc]-Nanocoll[reg

  17. E3-transitions in sup(105, 107, 109, 111)Ag

    International Nuclear Information System (INIS)

    Shevelev, G.A.; Troitskaya, A.G.; Kartashov, V.M.

    1978-01-01

    Electron radiation of the isomeric transitions of the sup(105-111)Ag odd nuclei was studied using an iron magnetic πsup(√2) beta spectrometer. For most isomeric transitions, relative intensities of the K, L, M, and N lines have been measured; for sup(105-111)Ag and 111 Cd they were measured for the first time. Energy of gamma transitions, relative intensities of internal conversion electrons (ICE) compared with the theoretical ICE values for the E3 transitions are presented. The observations for all the shells are in a fairly gool agreement with the calculations. Systematics of low-lying excited states of the silver nuclei involved is proposed. It has been established that spins and parities of the first excited states of the sup(105-111)Ag odd nuclei are 7/2 + . Multipolarities of isomeric transitions from these staes are pure E3. Spin and parity 9/2 + of the second excited states may be uniquely determined unly for 109 Ag from direct measurements of the ICE transition at 45.8 keV

  18. Evaluation of anticancer peptide VEGF111b secretion in HEK293 human cells

    Directory of Open Access Journals (Sweden)

    Morteza Sadeghi

    2017-04-01

    Full Text Available Background: VEGF111b is a new isoform of vascular endothelial growth factor (VEGF recently considered as a new anticancer drug. The aim of this study was to evaluate the VEGF111b secretion from HEK293 cell wall in order to commercial production of this recombinant factor. Materials and Methods: After the design of VEGF111b sequence using OLIGO software and NCBI gene bank data, it was cloned into the pBUD.cE4.1 vector. The pBUD.VEGF111b recombinant vector was transfected into HEK293 cells using lipofectamine kit. Forty-eight hours after the transfection the production of VEGF111b was estimated by Western blotting and Human anti VEGF antibody. The VEGF111b secretion into cell culture and cell lysate extract was measured using ELISA. Results: The correct cloning of VEGF111b into pBUD.cE4.1vector was confirmed using enzymatic digestion and gel electrophoresis. The observed production of recombinant peptide in HEK293 was confirmed with 12KDa band in cell lysate extract of Western blotting. The ELISA results at 450 nanometer absorbance for cell culture media and cell lysate extract were 19.20±2.81 pg/ml and 32.87±7.42 pg/ml, respectively. However, no VEGF111b expression was observed in negative controls. Conclusion: The findings of this study indicate the powerful ability of transformation and secretion of VEGF111b from HEK293 cell wall to cell culture media with no breaking and proteolytic digestion. It seems that the commercial production and purification of this therapeutic peptide from HEK293 cell culture would be possible with high efficiency.

  19. 15 CFR 930.111 - OCRM mediation.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false OCRM mediation. 930.111 Section 930... FEDERAL CONSISTENCY WITH APPROVED COASTAL MANAGEMENT PROGRAMS Secretarial Mediation § 930.111 OCRM mediation. The availability of mediation does not preclude use by the parties of alternative means for...

  20. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  1. Evaluation of carcinoma of the cervix using 111In-bleomycin

    International Nuclear Information System (INIS)

    Woolfenden, J.M.; Waxman, A.D.; Disaia, P.J.; Siemsen, J.K.

    1975-01-01

    Indium-111 attached to bleomycin is useful in the scintigraphic localization of a variety of tumors. Since it does not normally accumulate in bowel and feces, it is superior to other radiopharmaceuticals, such as gallium-67-citrate, in the demonstration of abnormalities in the abdomen and pelvis. Twenty-eight patients with known carcinoma of the cervix were studied with whole body 111 In-bleomycin scans. Two ''false-positive'' scans were produced by local inflammation. Six ''false-negative'' scans were attributed to small tumors escaping scintigraphic detection. In the remaining 20 patients, scan findings correlated well with site and extent of the tumor as determined by other means. 111 In-bleomycin scintiscanning may prove to be a highly useful adjunct in the evaluation of patients with carcinoma of the cervix

  2. Use of indium-111-oxinate-labelled granulocytes and thrombocytes in kidney transplantation

    International Nuclear Information System (INIS)

    Royen, E.A. van; Schoot, J.B. van der; Hardeman, M.R.; Surachno, S.; Veen, J.H. ten; Vreeken, J.; Wilmink, J.M.

    1981-01-01

    The diagnostic use of 111 In-oxinate-labelled granulocytes and thrombocytes in kidney graft rejection was studied in 39 transplant patients. Normal values were established for the deposition of these cells in stable, functioning kidney grafts. Although some 111 In granulocyte accumulation occurred in the graft during rejection, the increase was too slight to render the method suitable for the early diagnosis of rejection. Significant increased 111 In thrombocyte deposition was found during rejection periods, although large differences were observed in the degree of accumulation. Severity or type of rejection may relate to these differences. Post-transplantation follow-up by 111 In thrombocyte scintigraphy did not result in a much earlier diagnosis of rejection than classic clinical signs. However, more frequent bedside activity determinations might do so. (author)

  3. In-111-oxine-labeled negative liposomes in tumor-bearing mice

    International Nuclear Information System (INIS)

    Chatal, J.F.; Guihard, D.; Bardy, A.; Pasqualini, R.

    1983-01-01

    The distribution of In-111-oxine-labelled liposomes in C 57 Bl 6 mice bearing a Lewis lung tumor and the variations contingent on modification of certain parameters have been studied. The distribution has been compared with that of Ga-67 citrate which is known for its affinity for lung tumors. In conclusion, it may be said that In-111-labeled negatively charged liposomes handled in oxygen-free conditions and having a size smaller than 80 nm make it possible to visualize a murine tumor as well, and even better, than does Ga-67 citrate

  4. 46 CFR 111.105-33 - Mobile offshore drilling units.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Mobile offshore drilling units. 111.105-33 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-33 Mobile offshore drilling units. (a) Applicability. This section applies to each mobile offshore drilling unit. (b) Definitions. As used in this...

  5. Integrity of 111In-radiolabeled superparamagnetic iron oxide nanoparticles in the mouse

    International Nuclear Information System (INIS)

    Wang, Haotian; Kumar, Rajiv; Nagesha, Dattatri; Duclos, Richard I.; Sridhar, Srinivas; Gatley, Samuel J.

    2015-01-01

    Introduction: Iron-oxide nanoparticles can act as contrast agents in magnetic resonance imaging (MRI), while radiolabeling the same platform with nuclear medicine isotopes allows imaging with positron emission tomography (PET) or single-photon emission computed tomography (SPECT), modalities that offer better quantification. For successful translation of these multifunctional imaging platforms to clinical use, it is imperative to evaluate the degree to which the association between radioactive label and iron oxide core remains intact in vivo. Methods: We prepared iron oxide nanoparticles stabilized by oleic acid and phospholipids which were further radiolabeled with 59 Fe, 14 C-oleic acid, and 111 In. Results: Mouse biodistributions showed 111 In preferentially localized in reticuloendothelial organs, liver, spleen and bone. However, there were greater levels of 59 Fe than 111 In in liver and spleen, but lower levels of 14 C. Conclusions: While there is some degree of dissociation between the 111 In labeled component of the nanoparticle and the iron oxide core, there is extensive dissociation of the oleic acid component

  6. 46 CFR 111.60-6 - Fiber optic cable.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fiber optic cable. 111.60-6 Section 111.60-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-6 Fiber optic cable. Each fiber optic cable must— (a) Be...

  7. Evaluation of possible hip prosthesis infection with In-111 leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Noto, R.B.; Alavi, A.; Star, A.M.; Cuckler, J.M.; Eisenberg, B.

    1987-01-01

    To evaluate the utility of In-111 leukocyte scintigraphy in patients with possible hip prosthesis infection, the authors retrospectively reviewed 44 such scans without clinical history. The results of In-111 leukocyte scans were compared with intraoperative cultures obtained at the time of prosthesis revision in 34 patients, with hip aspirates and/or clinical follow-up obtained in the remaining ten patients. This comparison yielded a 71% sensitivity, 78% specificity, and 77% overall accuracy. They conclude that In-111 leukocyte scans can be helpful in the evaluation of suspected hip prosthesis infection, but they are not as accurate as has been previously reported elsewhere

  8. 14 CFR 1214.111 - Rendezvous services.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Rendezvous services. 1214.111 Section 1214....111 Rendezvous services. (a) A rendezvous mission involves the rendezvous of the Space Shuttle orbiter... conditions for both dedicated and shared flight rendezvous services will be negotiated on a case-by-case...

  9. Imaging experimental infective endocarditis with indium-111-labeled blood cellular components

    International Nuclear Information System (INIS)

    Riba, A.L.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1979-01-01

    The capability of radionuclide imaging to detect experimental aortic valve infective endocarditis was assessed with indium-111 ( 111 In)-labeled blood cells. Sequential cardiac imaging and tissue distribution studies were obtained in 17 rabbits with infective endocarditis after administration of 111 In-platelets and in five after 111 In-polymorphonuclear leukocytes. Forty-eight to 72 hours after platelet administration, in vivo imaging demonstrated abnormal 111 In uptake in all animals in the region of the aortic valve in an anatomically distinct pattern. Images of the excised heart showed discrete cardiac uptake conforming to the in vivo image and gross pathological examination. 111 In-platelet uptake in vegetations from the 17 animals averaged 240 +- 41 times greater than that in normal myocardium and 99 +- 15 times greater uptake in blood. In contrast, 111 In-leukocyte cardiac imaging showed no abnormal aortic valve uptake 24 hours after tracer administration and the lesion myocardium activity ratio was only 5 +- 2 (3 +- 1 for lesion/blood activity). Four normal rabbits demonstrated neither positive 111 In-platelet scintigraphs nor abnormal cardiac tissue uptake. Likewise, noncellular 111 In was not concentrated to any significant extent in three animals with infective endocarditis. This study demonstrates that 111 In-platelet, but not leukocyte cardiac imaging, is a sensitive technique for detecting experimental infective endocarditis. The imaging data conform to the cellular pathology of the infective endocarditis vegetation

  10. 46 CFR 111.10-5 - Multiple energy sources.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Multiple energy sources. 111.10-5 Section 111.10-5...-GENERAL REQUIREMENTS Power Supply § 111.10-5 Multiple energy sources. Failure of any single generating set energy source such as a boiler, diesel, gas turbine, or steam turbine must not cause all generating sets...

  11. 39 CFR 601.111 - Interest on claim amounts.

    Science.gov (United States)

    2010-07-01

    ... that date is later, until the date of payment. Simple interest will be paid at the rate established by... 39 Postal Service 1 2010-07-01 2010-07-01 false Interest on claim amounts. 601.111 Section 601.111... PROPERTY RIGHTS OTHER THAN PATENTS PURCHASING OF PROPERTY AND SERVICES § 601.111 Interest on claim amounts...

  12. 46 CFR 111.105-35 - Vessels carrying coal.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying coal. 111.105-35 Section 111.105-35...-GENERAL REQUIREMENTS Hazardous Locations § 111.105-35 Vessels carrying coal. (a) The following are Class II, Division 1, (Zone 10 or Z) locations on a vessel that carries coal: (1) The interior of each coal...

  13. 46 CFR 111.70-1 - General.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General. 111.70-1 Section 111.70-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS..., except when a wye-delta or a delta-wye transformer is used. (c) The motor disconnecting means must be an...

  14. Thallium-201 scintigraphy in diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Corne, R.A.; Gotsman, M.S.; Weiss, A.; Enlander, D.; Samuels, L.D.; Salomon, J.A.; Warshaw, B.; Atlan, H.

    1979-01-01

    The sensitivity of rest and exercise thallium-201 scintigraphy for the detection of significant coronary artery disease and myocardial ischaemia was compared with rest and exercise electrocardiography in 46 patients with chest pain. Of 26 patients with greater that 70 per cent coronary stenosis, 16 had abnormal rest thallium-201 scintigrams and 13 had Q waves. Myocardial perfusion defects in the resting scintigram correlated very well with evidence of previous myocardial infarction (16 of 17 patients, 94%) significant Q waves were present in 13 of these 17 patients (76%). After exercise, abnormal thallium-201 scintigrams consistent with ischaemia were found in 21 patients (81%). Abnormal exercise electrocardiograms were present in 15 patients (58%). The combination of abnormal exercise thallium-201 scintigrams or exercise electrocardiograms (23/26, 88%) exceeded abnormal exercise electrocardiograms alone (15/26, 58%). The two procedures were thus complementary. Abnormal rest or exercise thallium-201 scintigrams were obtained in 25/26 patients (96%) compared with abnormal rest or exercise electrocardiograms in 21/26 patients (84%). Twenty patients with less than 50 per cent coronary stenosis had normal rest thallium-201 scintigrams and no Q waves. Two had abnormal exercise thallium-201 scintigrams and 7 had abnormal exercise electrocardiograms. Thus,exercise thallium scintigraphy has higher sensitivity than exercise electrocardiography in detecting exercise induced ischaemia and is more specific. Scintigraphy appears to have a higher sensitivity than electrocardiography in detecting coronary artery disease. (author)

  15. Study of impurity-defect interaction by perturbed angular correlations: 111Cd in silver

    International Nuclear Information System (INIS)

    Sage, Francoise.

    1975-01-01

    The quadrupole interaction of 111 Cd nuclei following the decay of 111 In implanted by the 109 Ag(α,2n) 111 In reaction into a cubic Ag lattice was measured using the time-differential perturbed-angular correlation technique. A non vanishing quadrupole interaction corresponding to a distribution of electric field gradients was observed, due to the interaction between the 111 Cd impurity and the defects created during the recoil of 111 In nuclei. For low temperature (77 K) irradiations, it has been shown that i) the angular correlation pattern depends on the intensity of α beam current, due to the interaction between defect cascades at high α beam intensity; and ii) it also depends on the annealing of the irradiated sample at different temperatures; the change in the defect configuration around the impurities is then due to the mobility of the various defects [fr

  16. New results on elements 111 and 112

    International Nuclear Information System (INIS)

    Hofmann, S.; Hessberger, F.P.; Ackermann, D.

    2002-01-01

    Experiments on the synthesis and identification of the nuclei 272 111 and 277 112 were performed in order to confirm previous results. Three additional decay chains were measured in the reaction 64 Ni + 209 Bi → 273 111 * . The study revealed considerably improved data on the decay chain originating from 272 111. One additional chain was measured in the reaction 70 Zn + 208 Pb → 278 112 * . The decay properties of the chain starting at 277 112 are in excellent agreement with the second chain of the first experiment down to 265 Sg, where the new chain ends by a previously unknown spontaneous-fission branch. A re-analysis of all data on elements 110, 111, and 112 measured at GSI since 1994 (a total of 34 decay chains was investigated) revealed that for 2 chains (second chain of 269 110 measured in 1994 and first chain of 277 112 measured in 1996) the results of the new analysis differed from the previous one. In all other cases the earlier data are exactly reproduced. (orig.)

  17. Indium-111 leukocyte imaging in appendicitis

    International Nuclear Information System (INIS)

    Navarro, D.A.; Weber, P.M.; Kang, I.Y.; dos Remedios, L.V.; Jasko, I.A.; Sawicki, J.E.

    1987-01-01

    Indium- 111 -labeled leukocyte scintigraphy was applied to the diagnosis of acute appendicitis. Thirty-two patients observed in the hospital for possible appendicitis were prospectively studied. Scanning was done 2 hr after radiopharmaceutical injection. Thirteen scans were positive for acute appendicitis, and all but one were confirmed at laparotomy. In addition, two cases of colitis and two cases of peritonitis were detected. Of 15 negative studies, 11 had a benign course. Four patients with negative studies had laparotomy; two were found to have appendicitis and two had a normal appendix. Of 14 proven cases of appendicitis, 12 scans were positive for appendicitis with one false-positive scan, providing a sensitivity of 86%. Specificity was 93%: all negative cases except one had negative scans. Overall accuracy was 91% (29 of 32), comparing favorably with the accepted false-positive laparotomy rate of 25%. Use of In- 111 -labeled leukocyte scintigraphy serves to reduce the false-positive laparotomy rate and to shorten the clinical observation time in patients with acute appendicitis

  18. 46 CFR 111.01-5 - Protection from bilge water.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Protection from bilge water. 111.01-5 Section 111.01-5...-GENERAL REQUIREMENTS General § 111.01-5 Protection from bilge water. Each of the following in or around the bilge area must be arranged or constructed so that it cannot be damaged by bilge water: (a...

  19. sup(99m)Tc-sulfur-rhenium-colloid and 111In-indiumcitrate in the bone marrow scintigraphy

    International Nuclear Information System (INIS)

    Glaubitt, D.; Haberland, K.; Knoch, K.; Fejer, F.L.; Zachariah, S.; Staedtische Krankenanstalten Krefeld

    1975-01-01

    Bone marrow scintigraphy using 111 In-Indium-citrate and sup(99m)Tc-sulfur rhenium colloid was compared with each other in 6 male and 3 female patients. Our results in all patients were in favour of 111 In-citrate which caused a better delineation of morphological details than sup(99m)Tc-sulfur rhenium colloid did. In the first days after intravenous administration of 111 In-citrate, radioindium accumulated markedly in the pudendal region, this finding being more distinct in male patients than in female ones. On account of these results a considerable radiation dose has to be assumed in bone marrow scintigraphy using 111 In-citrate as long as the absorbed dose from 111 In has not been estimated under consideration of the radioindium accumulation in the pudendal region. 111 In-citrate should be applied in bone marrow scanning only exceptionally and sup(99m)Tc-sulfur rhenium colloid be preferred in the routine diagnostics of bone marrow. (orig.) [de

  20. The growth of Fe clusters over graphene/Cu(111)

    International Nuclear Information System (INIS)

    Takahashi, Keisuke

    2015-01-01

    The growth of Fe clusters up to nine atoms over graphene/Cu(111) is investigated within the density functional theory. Graphene is weakly physisorbed on Cu(111) through van der Waals force. The structures of Fe clusters over graphene/Cu(111) grow differently compared to gas-phase Fe clusters where Fe clusters are predicted to form towards a pyramid-like structure on graphene/Cu(111). The graphene is negatively charged upon the adsorption of Fe clusters as a result of charge transfer from Fe to graphene. Despite the fact that the electronic structure of graphene is affected by Fe clusters, magnetic moment of Fe clusters over graphene/Cu(111) remains relatively high. This suggests that graphene can be a potential substrate for supporting Fe clusters towards applications in magnetism and catalysis. (paper)

  1. Ag on Si(111) from basic science to application

    Energy Technology Data Exchange (ETDEWEB)

    Belianinov, Aleksey [Iowa State Univ., Ames, IA (United States)

    2012-01-01

    In our work we revisit Ag and Au adsorbates on Si(111)-7x7, as well as experiment with a ternary system of Pentacene, Ag and Si(111). Of particular interest to us is the Si(111)-(√3x√3)R30°}–Ag (Ag-Si-√3 hereafter). In this thesis I systematically explore effects of Ag deposition on the Ag-Si-√3 at different temperatures, film thicknesses and deposition fluxes. The generated insight of the Ag system on the Si(111) is then applied to generate novel methods of nanostructuring and nanowire growth. I then extend our expertise to the Au system on the Ag-Si(111) to gain insight into Au-Si eutectic silicide formation. Finally we explore behavior and growth modes of an organic molecule on the Ag-Si interface.

  2. Infection imaging with 99mTc-biotin in patients with prosthetic hip replacement

    International Nuclear Information System (INIS)

    Villa, G.; Mariani, G.; Augeri, C.; Pipino, F.; Paganelli, G.; Chinol, M.

    2002-01-01

    Full text: Although the incidence of infection in prosthetic hip joint replacements has decreased from about 10-15 % to about 0.5-2 % over the last 20 years, the total number of infections has actually increased because of the large number of patients undergoing the procedure. The most frequent clinical presentation of this complication is functional impairment and pain, with or without fever and other signs and/or symptoms of infection. The main is differentiating true infection from simple loosening with inflammation of the implanted stem. Scintigraphy with radiolabeled autologous leukocytes (WBC) represents the 'gold standard' nuclear medicine procedure for imaging infection. However, this procedure is time-consuming, expensive, and involves some biological hazard. Preliminary data, obtained during validation of the avidin/111In-biotin approach, have suggested some potential of 111ln-biotin per se to accumulate at sites of infection. In this pilot study we explored the potential of 99mTc-biotin as an infection imaging agent in pts with orthopedic infections. N4-lys-biotin was labeled with 1110 MBq. Sixteen pts bearing a total of 20 prosthetic hip replacements were enrolled in the study (9 women and 7 men, mean age 73.2 yrs). Eight pts had previously undergone removal of their hip prosthesis because of infection, while infection was suspected in the remaining 8 pts. Scintigraphy was recorded 20 min, then 1, 4 and 24 hr after the i.v. injection of 99mTc-biotin. Within 48 hrs of the 99mTc-biotin study, all pts also underwent scintigraphy with 99mTc-HMPAO-WBC. Out of the 20 hips evaluated, 15 turned out to be infected while in the remaining 5 cases pain was only caused by bone-prosthetic loosening and/or conditions other than infection. In 12/15 infected sites scintigraphy was concordantly positive with both procedures, 99mTc-biotin yielding higher target-to-nontarget ratios than 99mTc-HMPAO-WBC in 4 cases and similar values in the other cases. Discordant patterns

  3. Diagnosis of protein-losing gastroenteropathy by 111In-transferrin scanning and fecal excretion test

    International Nuclear Information System (INIS)

    Urita, Yoshihisa

    1991-01-01

    A total of 12 patients with gastroenteropathy were studied for possible protein loss. The underlying diseases were intestinal lymphangiectasia, ulcerative colitis and Crohn's disease in 2 patients each; and Menetrier's disease, Cronkhite-Canada syndrome, postgastrectomy syndrome, severe atrophic gastritis, gastric cancer and gastroenteropathy of unknown origin in one patient each. The controls were four healthy volunteers and 9 patients with benign disease not accompanied by lesions in the digestive tract and protein loss, 111 In-transferrin (Tf) was prepared by incubating 2-3 mCi of 111 In-chloride with 15-20 ml of each patient's plasma in a sterilized vial at room temperature for 1 hour. After i.v. injection of 111 In-Tf, the patients were scanned at given intervals of time for 72 hours to localize protein loss. Seventy-two hour fecal 111 In-Tf excretion was also measured. 111 In-Tf was detected in the feces of all patients. The recovery rate in the patient group was 7.95±3.65%, being significantly higher than 0.48±0.26% in the control group. However, 111 In-Tf scanning showed the site of protein loss only in 6 patients. Negative scan in six other patients was thought to be associated with extensive inflammation and severe diarrhea. Five of the 12 patients were observed before and after treatment. A decrease in fecal 111 In-Tf excretion with clinical improvement was noted in the 5 patients after treatment. The site of protein loss could be demonstrated in 3 of the 5 patients before treatment. Its site in 1 of the 3 patients was the small intestine. However, accumulation of 111 In-Tf was found there in the 3 patients after treatment. The site of protein loss in one of three patients was the small intestine. 111 In-Tf scanning is particularly useful when the small intestine is involved, because surgery is contraindicated in this case. Fecal 111 In-Tf excretion test is mandatory when the site of protein loss cannot be imaged. (author)

  4. Colonic localization of indium-111 labeled leukocytes in active Behcet's disease

    International Nuclear Information System (INIS)

    Harre, R.G.; Conrad, G.R.; Seabold, J.E.

    1988-01-01

    A patient with known Behcet's disease demonstrated intense colonic localization of In-111 labeled leukocytes. Gastrointestinal involvement had not been previously manifested, but extensive colonic inflammation was documented by endoscopy. This case illustrates the utility of In-111 labeled leukocyte imaging for detecting active bowel disease in a debilitated patient with documented Behcet's vasculitis

  5. The distribution of a new /sup 111/In-Bleomycin complex in tumor cells by autoradiography

    International Nuclear Information System (INIS)

    Hou, D.Y.; Maruyama, Y.

    1987-01-01

    A new radioactive form of Bleomycin (/sup 111/In-BLMC) was effective for tumor imaging and therapy in mouse glioma and human small cell lung cancer (SCLC) cells. The distribution of drug in tumor cells was investigated by autoradiography. Human small cell lung cancer (N417 and H526, NCI) were exposed to /sup 111/ InCl/sub 3/ and (25-150 μCi/ml) or /sup 111/In-BLMC (25-150 μCi) carried by 15-25 μg BLM/ml) in 37 0 C for 1 hr, 3 hr or 24 hr, washed with fresh medium, and spread. The slides were smeared with NTB/sub 2/ or NTB/sub 3/ emulsion by using wet-mounting or dry-mounting technique and developed 3-14 days. The /sup 111/In-BLMC localized on the cell nucleus (47.8%) and nuclear membrane (29.2%); /sup 111/InCl/sub 3/ located mainly in the cytoplasm (45.8%). This indicates that the mechanism of killing of tumor cells may be related to the drug uptake and distribution of /sup 111/In-BLMC. A nuclear and nuclear membrane localization would favor damage to chromosomes and DNA

  6. In vivo behavior of 111In-DTPA in rat and mouse after intra-ventricular administration

    International Nuclear Information System (INIS)

    Matsushima, Hiroaki; Kato, Makoto; Sugimura, Yukiharu; Hazue, Masaaki

    1977-01-01

    In vivo behavior of 111 In-DTPA in rat and mouse after intra-ventricular administration was studied. Thus, 50μCi and 35μCi of 111 In-DTPA was injected intraventricularly to rat and mouse respectively. At specific time intervals, the animals were sacrificed, then distribution in organs was determined by radioactivity counting and autoradiographic method. Urinary and fecal excretion were separately collected and excretion rates were estimated. Metabolites in urine of rat were examined with chromatography. A part of 111 In-DTPA injected intra-ventricularly to the animals migrated to subarachnoid space, then radioactivity in cerebrospinal fluid effused into blood with about 1 hr initial half-life. Blood clearance was also rapid, about 1 hr after administration the blood level reached maximum and then decreased showing an initial half-life of about 1 hr. The predominant excretion route in rat was urinary and about 90% and 5% of administered dose were excreted within 48 hr through urine and feces respectively. Judging from the Rf-value of radioactivity peak on chromatograms, 111 In-DTPA seems to be excreted without suffering any metabolic change. Concerning to the behavior of 111 In-DTPA in male and female rat, no difference was observed, and the distribution pattern of 111 In-DTPA in mouse was similar to that of rat. (auth.)

  7. Suppression of superconductivity in a single Pb layer on Ag/Si(111)

    Energy Technology Data Exchange (ETDEWEB)

    Leon-Vanegas, Augusto; Kirschner, Juergen [Max Plank Instituet fuer Mikrostukturphysik (Germany); Martin Luther Univeristaet, Halle-Wittenberg (Germany); Caminale, Michael; Stepniak, Agnieszka; Oka, Hirofumi; Sanna, Antonio; Linscheid, Andreas; Sander, Dirk [Max Plank Instituet fuer Mikrostukturphysik (Germany)

    2015-07-01

    Recently, superconductivity was reported in a single layer of Pb on Si(111) with a critical temperature of 1.83 K. It has been proposed that the interaction of Pb with the Si substrate provides the electron phonon coupling to support superconductivity in this system. We have used a {sup 3}He-cooled STM with a vector magnetic field to study the effect of insertion of a Ag interlayer on the superconducting properties of a single Pb layer on Si(111). In contrast to the experiments on Pb/Si(111), the differential conductance of Pb/Ag/Si(111) does not show a gap indicative of superconductivity even at the lowest experimental temperature of 0.38 K. We ascribe this to the suppression of superconductivity. This result is explained by means of ab-initio calculations, showing that the effect of a chemical hybridization between Pb and Ag/Si occurring at the Fermi level dramatically reduces the strength of the electron phonon coupling. This contrasts with the case of Pb/Si(111), where no overlap between Pb and Si electronic states at the Fermi level is found in the calculations.

  8. First principles study of pentacene on Au(111)

    OpenAIRE

    Stokbro, Kurt; Smidstrup, Søren

    2013-01-01

    We investigate the atomic and electronic structure of a single layer of pentacene on the Au(111) surface using density functional theory. To find the candidate structures we strain match the pentacene crystal geometry with the Au(111) surface, in this way we find pentacene overlayer structures with a low strain. We show that the geometries obtained with this approach has lower energy than previous proposed surface geometries of pentacene on Au(111). We also show that the geometry and workfunc...

  9. A study on hepato-biliary and alimentary scintigram by means of triple tracer method

    International Nuclear Information System (INIS)

    Aibata, Hirofumi; Torizumi, Kazutami; Okada, Takashi; Kiji, Shigeyuki; Yamada, Ryusaku; Shimada, Kosuke; Taniguchi, Katsutoshi; Aoki, Yozo

    1987-01-01

    In order to evaluate the gastric emptying and postprandial mixing of bile with food, the scintigraphies of hepatobiliary and gastrointestinal tracts by using three different kinds of radioisotopes were performed simultaneously ( 99m Tc-E · HIDA for hepatobiliary scintigraphy, 111 In-DTPA containing orange juice and 131 I-albumin containing scrambled egg for gastrointestinal scintigraphy). This method was available for observation of gastric emptying of liquid and solid foods and also examination of the mixing effect of bile and food quantitatively. (author)

  10. Parathyroid scintigraphy during hypocalcaemia in primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Øgard, Christina G; Vestergaard, Henrik; Thomsen, Jørn B

    2005-01-01

    .3%. Then 700 MBq (99m)Tc-sestamibi was injected and another scintigram of the neck was obtained. Perchlorate was given at the end of the sestamibi scintigram to increase the wash-out of (99m)Tc-pertechnetate from the thyroid gland, and after 2 h a delayed scintigram was obtained. A subtraction of the thyroid...

  11. Activity measurements of the radionuclide {sup 111}In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G.; Courte, S. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, 92 - Sevres (France); Verdeau, E.; Amiot, M.N. [Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France)

    2010-10-15

    In 2006, the Laboratoire national de metrologie et d'essais - Laboratoire national Henri Becquerel (LNE-LNHB) submitted a sample of known activity of {sup 111}In to the International Reference System (SIR). The value of the activity submitted was about 14 MBq. This provides a new result for France in the matrix of degrees of equivalence in the key comparison database that enables them to maintain their degrees of equivalence for this radionuclide. The key comparison reference value has been re-evaluated and the comparison, identifier BIPM.RI(II)-K1.In-111, now contains five valid results. (authors)

  12. Diagnosis of cardiac allograft rejection with indium-111 labeled platelets in cyclosporin treated rats

    International Nuclear Information System (INIS)

    Fawwaz, R.A.; Iga, C.; Hardy, M.A.; Alderson, P.O.

    1984-01-01

    Rejection of heart transplants remains difficult to diagnose. Indium-111 (In-111) labeled lymphocytes accumulate in rat cardiac allografts when recipients are treated with Cyclosporin (Cy), even in the absence of clinical rejection. This presumably occurs because of the non-specific 'interstitial infiltration' caused by Cy. This study examines the usefulness of In-111 labeled platelets in differentiating experimental cardiac allograft rejection from Cy-induced tissue changes. The authors initially examined the migration patterns of syngeneic In-111 labeled platelets in groups of Lewis recipients of ACI cardiac allografts treated with IM Cy (10mg/kg) for 6-14 days. In addition, 10 control animals were not immunosuppressed, and 10 were treated with Cy but received Lewis cardiac isografts. Syngeneic In-111 platelets were injected IV into each animal 24 hours prior to sacrifice. Three to five rats from each group were killed at 3 ,7, 14, 21 and 28 days after transplantation and the % ID/gm in the transplanted hearts and native hearts were determined and correlated with histopathology. Untreated Lewis recipients rejected ACI hearts in 6.5 +- 0.4 days while Cy prolonged allograft survival in a variable fashion. In-111 platelet accumulation correlated well with the degree of rejection determined independently by histopathology. No significant In-111 platelet accumulation was detected in non-rejecting cardiac transplants or in native hearts in Cy treated or control animals. The results suggest that In-111 labeled platelets will be an effective agent for diagnosis of cardiac rejection, even in the presence of Cy treatment

  13. Indium-111 chloride imaging in the detection of infected prostheses

    International Nuclear Information System (INIS)

    Sayle, B.A.; Fawcett, H.D.; Wilkey, D.J.; Cierny, G. III; Mader, J.T.

    1985-01-01

    Thirty-three patients with painful joint prostheses and a suspicion of infection were imaged with [ 111 In]chloride. A final diagnosis was established by culture in 19. Of these, 12 were categorized as true positives and three as true negatives. There were two false-positive studies, occurring in patients with knee prostheses. In both, the culture was obtained by aspiration. The sensitivity was 86%, specificity 60%, and accuracy 79%. Seventeen of the proven cases had bone imaging prior to [ 111 In]chloride imaging. All 17 static images were positive and were not helpful in differentiating loosening from infection. Using increased uptake on the blood-pool image as a criteria for infection, the sensitivity was 89%, but the specificity was 0. Adding flow studies made little difference in interpreting the blood-pool images. This study shows that [ 111 In]chloride imaging is more accurate in evaluating infection in prosthesis than bone imaging

  14. 11 CFR 111.22 - Ex parte communications.

    Science.gov (United States)

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Ex parte communications. 111.22 Section 111.22 Federal Elections FEDERAL ELECTION COMMISSION GENERAL COMPLIANCE PROCEDURE (2 U.S.C. 437g, 437d(a... and any attorney or staff member of the Office of General Counsel in the course of representing the...

  15. {sup 111}In-DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide, {sup 111}In-DOTA-lanreotide and {sup 67}Ga citrate scintigraphy for visualisation of extranodal marginal zone B-cell lymphoma of the MALT type: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuren; Kurtaran, Amir; Li, Mei; Traub-Weidinger, Tatjana; Kienast, Oskar [Department of Nuclear Medicine, University of Vienna, Waehringer Guertel 18-20, 1090, Vienna (Austria); Schima, Wolfgang [Department of Nuclear Medicine, University of Vienna, Waehringer Guertel 18-20, 1090, Vienna (Austria); Department of Radiodiagnostics, University of Vienna (Austria); Angelberger, Peter [Research Center Seibersdorf (Austria); Virgolini, Irene [Institute for Nuclear Medicine, Vienna Hospital Lainz (Austria); Ludwig-Boltzman Institute for Nuclear Medicine, Vienna (Austria); Raderer, Markus [Department of Internal Medicine I, Division of Oncology, University of Vienna (Austria); Dudczak, Robert [Department of Nuclear Medicine, University of Vienna, Waehringer Guertel 18-20, 1090, Vienna (Austria)

    2003-08-01

    Somatostatin receptor (SSTR) scintigraphy and gallium-67 citrate ({sup 67}Ga) scintigraphy have been used for visualisation of Hodgkin's lymphoma and non-Hodgkin's lymphoma. However, experience with B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT) type is very limited. The aim of this study was to prospectively compare the {sup 67}Ga scintigraphy results with those obtained by {sup 111}In-DOTA-dPhe{sup 1}-Tyr{sup 3}-octreotide ({sup 111}In-DOTA-TOCT) and {sup 111}In-DOTA-lanreotide ({sup 111}In-DOTA-LAN) scintigraphy in patients with proven MALT-type lymphoma. Comparative scintigraphic examinations using {sup 67}Ga, {sup 111}In-DOTA-TOCT and {sup 111}In-DOTA-LAN were performed in 18 patients (11 female and 7 male, median age 64{+-}15 years) with histologically verified MALT-type lymphomas of various origin. Planar and single-photon emission tomography imaging acquisitions were performed after injection of a mean dose of 185{+-}26 MBq {sup 67}Ga and 165{+-}20 MBq {sup 111}In-DOTA-TOCT or {sup 111}In-DOTA-LAN. All scintigraphic results were correlated with other conventional examinations including gastroscopy, colonoscopy, endosonoscopy, ophthalmologic investigation, CT of the thorax and abdomen and bone marrow biopsy. This comparative study showed that {sup 67}Ga scintigraphy found abnormalities in 10 of 16 patients (63%) and detected 18 of 31 clinically involved sites (58%), but was false positive in three patients. {sup 111}In-DOTA-TOCT found abnormalities in 9 of 15 patients (60%) and detected 15 of 27 clinical lesions (56%); it was false positive in two patients. {sup 111}In-DOTA-LAN scintigraphy showed abnormalities in 7 of 11 patients (64%) and found 12 of 22 clinical lesions (55%). False-positive {sup 111}In-DOTA-LAN scan results were found in two patients. For supra-diaphragmatic lesions, {sup 67}Ga scintigraphy detected 12 of 16 sites (75%). {sup 111}In-DOTA-TOCT scintigraphy revealed 7 of 15 lesions (47%). {sup 111}In

  16. Kinetics of transformation of 1,1,1-trichloroethane by Fe(II) in cement slurries

    International Nuclear Information System (INIS)

    Jung, Bahngmi; Batchelor, Bill

    2009-01-01

    This study examines the applicability of the iron-based degradative solidification/stabilization (DS/S-Fe(II)) process to 1,1,1-trichloroethane (1,1,1-TCA), which is one of common chlorinated aliphatic hydrocarbons (CAHs) of concern at contaminated sites. DS/S-Fe(II) combines contaminant degradation by Fe(II) and immobilization by the hydration reactions of Portland cement. The transformation of 1,1,1-TCA by Fe(II) in 10% Portland cement slurries was studied using a batch slurry reactor system. The effects of Fe(II) dose, pH, and initial concentration of 1,1,1-TCA on the kinetics of 1,1,1-TCA degradation were evaluated. Degradation of 1,1,1-TCA in cement slurries including Fe(II) was very rapid and could be described by a pseudo-first-order rate law. The half-lives for 1,1,1-TCA were measured between 0.4 and 5 h when Fe(II) dose ranged from 4.9 to 39.2 mM. The pseudo-first-order rate constant increased with pH to a maximum near pH 12.5. A saturation rate equation was able to predict degradation kinetics over a wide range of target organic concentrations and at higher Fe(II) doses. The major transformation product of 1,1,1-TCA in mixtures of Fe(II) and cement was 1,1-dichloroethane (1,1-DCA), which indicates that degradation occurred by a hydrogenolysis pathway. A small amount of ethane was observed. The conversion of 1,1,1-TCA to ethane was better described by a parallel reaction model than by a consecutive reaction model

  17. ALX 111: ALX1-11, parathyroid hormone (1-84) - NPS Allelix, PREOS, PTH, recombinant human parathyroid hormone, rhPTH (1-84).

    Science.gov (United States)

    2003-01-01

    ALX 111 [parathyroid hormone (1-84) - NPS Allelix, recombinant human parathyroid hormone, rhPTH (1-84), PREOS] is a full-length, recombinant human parathyroid hormone. It has potential as an anti-osteoporotic agent, due to its properties as a bone formation stimulant. This profile has been selected from R&D Insight, a pharmaceutical intelligence database produced by Adis International Ltd. It has been recommended that ALX 111 should be given for 1 to 2 years and may be given in combination with an antiresorptive agent, such as estrogen or a bisphosphonate. In December 1999, Allelix Biopharmaceuticals merged with NPS Pharmaceuticals. This combined company is operating as NPS Pharmaceuticals in the US and as NPS Allelix in Canada. The merger has enabled a phase III study of ALX 111 to begin in the US, Europe and South America. NPS harmaceuticals has signed an agreement with Bio-Imaging Technologies, which will provide all image handling and analysis for this trial. Until 1994, Allelix Biopharmaceuticals and Glaxo in Canada were involved in a joint venture to investigate the efficacy of ALX 111 in osteoporosis. Allelix was subsequently, until September 1998, collaborating with Astra of Sweden in developing ALX 111. Astra had acquired exclusive worldwide rights to ALX 111 and was responsible for development of the agent. However, Astra returned all rights to ALX 111 to Allelix as a result of its merger with Zeneca to form AstraZeneca. In December 1999, Allelix Biopharmaceuticals merged with NPS Pharmaceuticals. This combined company is operating as NPS Pharmaceuticals in the US and as NPS Allelix in Canada. The merger has enabled a phase III study of ALX 111 to begin in the US, Europe and South America. The phase III trial of ALX 111 for the treatment of osteoporosis has completed patient enrolment, and phase II trials have been completed in Canada and the Netherlands. The 18-month, phase III, multicentre, placebo-controlled trial (Treatment of Osteoporosis with

  18. Detection of restenosis after successful coronary angioplasty: Improved clinical decision making with use of a logistic model combining procedural and follow-up variables

    International Nuclear Information System (INIS)

    Renkin, J.; Melin, J.; Robert, A.; Richelle, F.; Bachy, J.L.; Col, J.; Detry, J.M.; Wijns, W.

    1990-01-01

    A prospective study of 111 patients who underwent repeat coronary angiography and exercise thallium-201 scintigraphy 6 +/- 2 months after complete revascularization by percutaneous transluminal coronary angioplasty was performed to assess whether clinical, procedure-related and postangioplasty exercise variables yield independent information for the prediction of angiographic restenosis after angioplasty. Complete revascularization was defined as successful angioplasty of one or more vessels that resulted in no residual coronary lesion with greater than 50% diameter stenosis. Restenosis was defined as a residual stenosis at the time of repeat angiography of greater than 50% of luminal diameter. Restenosis occurred in 40% of the patients. The 111 patients were randomly subdivided into a learning group (n = 84) and a testing group (n = 27). A logistic discriminant analysis was performed in the learning group and the logistic model was used to estimate a logistic probability of restenosis. This probability of restenosis was validated in the testing group. In the learning group of 84 patients univariate analysis of 39 factors revealed 8 factors related to restenosis: recurrence of angina (p less than 0.0001), postangioplasty abnormal finding on exercise thallium-201 scintigram (p less than 0.0001), exercise thallium-201 scintigram score (p less than 0.0001), difference between exercise and rest ST segment depression (p less than 0.001), postangioplasty exercise ST segment depression (p less than 0.001), absolute postangioplasty stenosis diameter (p less than 0.003), postangioplasty exercise work load (p less than 0.03) and postangioplasty exercise heart rate (p less than 0.05)

  19. Metal decomposition rates or 111In-DPTA and EDTA conjugates of monoclonal antibodies in vivo

    International Nuclear Information System (INIS)

    Goodwin, D.A.; McTigue, M.; Chaovapong, W.; Meares, C.F.; McCall, M.J.

    1986-01-01

    We have studied the metal chelate decomposition rates in vivo in both 111 In-labelled benzyl EDTA and DTPA (bicyclic anhydride) conjugates of monoclonal anti-IAsup(k) IgG2a with identical Kα = 1 x 10 11 M -1 in both Ag + ve and Ag -ve mice. Twenty μCi was given i.v. and whole body counting done immediately and daily for 10 days. Half the mice in each group received i.p. injections of 5.0 mg CaNa 2 EDTA chase (Versenate) to facilitate urinary excretion of free 111 In. 50% of control 111 In-citrate remained at nine days but only 8% with chase. No significant loss of 111 In with chase occurred with C 1 substituted EDTA conjugates. A 19% increase in excretion was demonstrated with the chase in mice give DTPA conjugates (1.9% per day). While this will not interfere with radioimmunoimaging up to 24 h after injection, waiting periods of a week or longer will produce significant background of free 111 In in the reticuloendothelial system, RES. 111 In-EDTA stability was important in accurate metabolic rate measurements of anti-IAsup(k); T1/2 = 7.0 days in Ag-ve mice, T1/2 = 9.3 days in Ag-ve mice. (author)

  20. Pharmacokinetics of 111In-labeled anti-p97 monoclonal antibody in patients with metastatic malignant melanoma

    International Nuclear Information System (INIS)

    Rosenblum, M.G.; Murray, J.L.; Haynie, T.P.; Glenn, H.J.; Jahns, M.F.; Benjamin, R.S.; Frincke, J.M.; Carlo, D.J.; Hersh, E.M.

    1985-01-01

    Twenty-eight patients with metastatic malignant melanoma received anti-p97 murine monoclonal antibody (96.5) infused over 2 h at doses between 1 and 20 mg coupled to either 2.5 or 5.0 mCi of 111 In by the bifunctional chelating agent diethyltriaminepentaacetic acid. Clearance of 111 In from plasma closely fit an open, one-compartment mathematical model (r2 greater than 0.90). The overall half-life of 111 In plasma was approximately 31 h and did not appear to be dependent on the total dose of antibody administered. The apparent volume of distribution of the 111 In label approximated the total blood volume (7.8 +/- 0.7 liters) at the 1-mg dose and decreased to 3.0 +/- 0.14 liters at the 20-mg dose, suggesting saturation of antigenic or other extravascular binding sites at higher antibody doses. The clearance of the murine monoclonal antibody itself from plasma was measured by an enzyme-linked immunosorbent assay. The pharmacokinetics for the murine antibody in plasma also fit an open, one-compartment mathematical model. All pharmacokinetic parameters for unlabeled antibody closely paralleled those found for 111 In-labeled antibody pharmacokinetics. This suggests that the 111 In radiolabel remains complexed to the monoclonal antibody after in vivo administration. The cumulative urinary excretion of the 111 In label over 48 h was between 12 and 23% of the total administered dose and is assumed to represent 111 In-labeled chelate complex unattached to antibody. Analysis of the 111 In label in spleen, liver, heart, and kidney showed that the concentration of label in liver tissue was reduced with increasing antibody doses and coincided with changes in the apparent volume of distribution

  1. Study of rotational band in 111Sn

    International Nuclear Information System (INIS)

    Ganguly, S.; Banerjee, P.; Ray, I.; Kshetri, R.; Raut, R.; Goswami, A.; Saha Sarkar, M.; Bhattacharya, S.; Mukherjee, A.; Mukherjee, G.; Basu, S.K.; Mukhopadhyay, S.

    2006-01-01

    The motivation of the present work is to study the negative-parity rotational band in 111 Sn. Study of the lifetimes of the states of the rotational band is expected to provide information on their structures as well as the band termination phenomenon

  2. Dehydrogenation of benzene on Pt(111) surface

    Science.gov (United States)

    Gao, W.; Zheng, W. T.; Jiang, Q.

    2008-10-01

    The dehydrogenation of benzene on Pt(111) surface is studied by ab initio density functional theory. The minimum energy pathways for benzene dehydrogenation are found with the nudge elastic band method including several factors of the associated barriers, reactive energies, intermediates, and transient states. The results show that there are two possible parallel minimum energy pathways on the Pt(111) surface. Moreover, the tilting angle of the H atom in benzene can be taken as an index for the actual barrier of dehydrogenation. In addition, the properties of dehydrogenation radicals on the Pt(111) surface are explored through their adsorption energy, adsorption geometry, and electronic structure on the surface. The vibrational frequencies of the dehydrogenation radicals derived from the calculations are in agreement with literature data.

  3. 20 CFR 653.111 - State agency staffing requirements.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false State agency staffing requirements. 653.111 Section 653.111 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR SERVICES... ethnic characteristics in the work force shall be distributed in substantially the same proportion among...

  4. 46 CFR 111.51-3 - Protection of vital equipment.

    Science.gov (United States)

    2010-10-01

    ...-GENERAL REQUIREMENTS Coordination of Overcurrent Protective Devices § 111.51-3 Protection of vital equipment. (a) The coordination of overcurrent protective devices must be demonstrated for all potential... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of vital equipment. 111.51-3 Section 111.51-3...

  5. Scintigraphic detection of coronary artery thrombi in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Fox, K.A.; Bergmann, S.R.; Mathias, C.J.; Powers, W.J.; Siegel, B.A.; Welch, M.J.; Sobel, B.E.

    1984-01-01

    To determine whether coronary thrombi can be detected scintigraphically after acute myocardial infarction, 24 patients were studied with a new method employing indium-111-labeled platelets and technetium-99m-labeled red blood cells. Nine patients with suspected infarction were evaluated initially within 9 hours of the onset of symptoms and again 18 to 24 hours after onset. Foci of net indium accumulation were detected after image processing that incorporated subtraction of blood pool activity. Carotid and pulmonary artery reference regions, in which blood pool activity is high and active platelet deposition unlikely, were used to correct digitized cardiac scintigrams for indium-111 platelet activity in the blood pool. In patients with infarction, distinct foci of net indium accumulation were present in regions corresponding to the coronary artery supplying ischemic zones. This occurred in seven of eight patients at the time of the earliest evaluation after the onset of symptoms) and in eight of nine patients at the time of subsequent imaging (23.6 +/- 1.9 hours after onset). Only 1 of 15 control patients exhibited a cardiac focus of net indium accumulation. The percent of indium excess (100 [total indium-111 activity-blood pool indium-111 activity]/blood pool indium-111 activity) within the cardiac region measured (+/- SD) 16.8 +/- 11.6% in all patients with myocardial infarction (19.1 +/- 11.2% in those with visually identified foci) compared with 0.4 +/- 4.3% in control patients. This method permits early detection and sequential assessment of coronary artery thrombi

  6. Polycythemia vera presenting with left hemichoreiform movements

    International Nuclear Information System (INIS)

    Mori, Tamiharu; Shimomura, Chikako; Ishibashi, Hiroshi; Tsujihata, Mitsuhiro; Nagataki, Shigenobu.

    1985-01-01

    A 65-year-old man developed abruptly choreiform movements involving the left face, arm and leg one day prior to admission. Physical examination revealed red face and palms, hyperemic conjunctivae and atrial fibrillations. Blood pressure was 168/90. Spleen was not palpable. Hemichoreiform movements of the left face and limbs were observed. There was no other neurological abnormalities. Laboratory studies showed RBC 880x10 4 , Hb 22.4g/dl, Hct 63%, WBC 8,100, platelets 22.9x10 4 , ESR 0mm/hr, RBC oxygen saturation 97%, serum iron 67 μg/dl, LDH 593 units, uric acid 14mg/dl, and erythropoietine (HI method) 19mIU/ml (normal 28-88). Bone marrow showed myeloid nucleated cell count 38.6x10 4 . ECG showed atrial fibrillations. Chest X-ray and scintigrams of liver and spleen were normal. CSF was normal. Brain CT scan on admission disclosed a low density area in right caudate nucleus. The choreiform movements were rapidly mitigated by venesection and by oral administration of haloperidol(3mg daily). There weeks after discontinuing haloperidol, the hemichorea returned. The routine hematology showed RBC 870x10 4 , Hb 19.8g/dl, Hct 62%, WBC 10,200, and plateret 37.4x10 4 . Another venesection reduced the chorea. Pipobroman was administered to control the polycythemia vera. He has been free of choreic movements thereafter. Choreiform movement is rarely observed in polycythemia vera. The pathogenesis is still unknown. The venous congestion, however, may play a role in this case because the choreic movements disappeared by venesection. (author)

  7. Polycythemia vera presenting with left hemichoreiform movements. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Tamiharu; Shimomura, Chikako; Ishibashi, Hiroshi; Tsujihata, Mitsuhiro; Nagataki, Shigenobu

    1985-01-01

    A 65-year-old man developed abruptly choreiform movements involving the left face, arm and leg one day prior to admission. Physical examination revealed red face and palms, hyperemic conjunctivae and atrial fibrillations. Blood pressure was 168/90. Spleen was not palpable. Hemichoreiform movements of the left face and limbs were observed. There was no other neurological abnormalities. Laboratory studies showed RBC 880 x 10U, Hb 22.4g/dl, Hct 63%, WBC 8,100, platelets 22.9 x 10U, ESR 0mm/hr, RBC oxygen saturation 97%, serum iron 67 g/dl, LDH 593 units, uric acid 14mg/dl, and erythropoietine (HI method) 19mIU/ml (normal 28-88). Bone marrow showed myeloid nucleated cell count 38.6 x 10U. ECG showed atrial fibrillations. Chest X-ray and scintigrams of liver and spleen were normal. CSF was normal. Brain CT scan on admission disclosed a low density area in right caudate nucleus. The choreiform movements were rapidly mitigated by venesection and by oral administration of haloperidol(3mg daily). There weeks after discontinuing haloperidol, the hemichorea returned. The routine hematology showed RBC 870 x 10U, Hb 19.8g/dl, Hct 62%, WBC 10,200, and plateret 37.4 x 10U. Another venesection reduced the chorea. Pipobroman was administered to control the polycythemia vera. He has been free of choreic movements thereafter. Choreiform movement is rarely observed in polycythemia vera. The pathogenesis is still unknown. The venous congestion, however, may play a role in this case because the choreic movements disappeared by venesection. (author).

  8. 21 CFR 111.460 - What requirements apply to holding in-process material?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to holding in-process material? 111.460 Section 111.460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN...

  9. Redesign of negatively charged 111In-DTPA-octreotide derivative to reduce renal radioactivity.

    Science.gov (United States)

    Oshima, Nobuhiro; Akizawa, Hiromichi; Kawashima, Hidekazu; Zhao, Songji; Zhao, Yan; Nishijima, Ken-Ichi; Kitamura, Yoji; Arano, Yasushi; Kuge, Yuji; Ohkura, Kazue

    2017-05-01

    Radiolabeled octreotide derivatives have been studied as diagnostic and therapeutic agents for somatostatin receptor-positive tumors. To prevent unnecessary radiation exposure during their clinical application, the present study aimed to develop radiolabeled peptides which could reduce radioactivity levels in the kidney at both early and late post-injection time points by introducing a negative charge with an acidic amino acid such as L-aspartic acid (Asp) at a suitable position in 111 In-DTPA-conjugated octreotide derivatives. Biodistribution of the radioactivity was evaluated in normal mice after administration of a novel radiolabeled peptide by a counting method. The radiolabeled species remaining in the kidney were identified by comparing their HPLC data with those obtained by alternative synthesis. The designed and synthesized radiolabeled peptide 111 In-DTPA-d-Phe -1 -Asp 0 -d-Phe 1 -octreotide exhibited significantly lower renal radioactivity levels than those of the known 111 In-DTPA-d-Phe 1 -octreotide at 3 and 24h post-injection. The radiolabeled species in the kidney at 24h after the injection of new octreotide derivative represented 111 In-DTPA-d-Phe-OH and 111 In-DTPA-d-Phe-Asp-OH as the metabolites. Their radiometabolites and intact 111 In-DTPA-conjugated octreotide derivative were observed in urine within 24h post-injection. The present study provided a new example of an 111 In-DTPA-conjugated octreotide derivative having the characteristics of both reduced renal uptake and shortened residence time of radioactivity in the kidney. It is considered that this kinetic control was achieved by introducing a negative charge on the octreotide derivative thereby suppressing the reabsorption in the renal tubules and affording the radiometabolites with appropriate lipophilicity. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Redesign of negatively charged 111In-DTPA-octreotide derivative to reduce renal radioactivity

    International Nuclear Information System (INIS)

    Oshima, Nobuhiro; Akizawa, Hiromichi; Kawashima, Hidekazu; Zhao, Songji; Zhao, Yan; Nishijima, Ken-ichi; Kitamura, Yoji; Arano, Yasushi; Kuge, Yuji; Ohkura, Kazue

    2017-01-01

    Introduction: Radiolabeled octreotide derivatives have been studied as diagnostic and therapeutic agents for somatostatin receptor-positive tumors. To prevent unnecessary radiation exposure during their clinical application, the present study aimed to develop radiolabeled peptides which could reduce radioactivity levels in the kidney at both early and late post-injection time points by introducing a negative charge with an acidic amino acid such as L-aspartic acid (Asp) at a suitable position in 111 In-DTPA-conjugated octreotide derivatives. Methods: Biodistribution of the radioactivity was evaluated in normal mice after administration of a novel radiolabeled peptide by a counting method. The radiolabeled species remaining in the kidney were identified by comparing their HPLC data with those obtained by alternative synthesis. Results: The designed and synthesized radiolabeled peptide 111 In-DTPA-D-Phe −1 -Asp 0 -D-Phe 1 -octreotide exhibited significantly lower renal radioactivity levels than those of the known 111 In-DTPA-D-Phe 1 -octreotide at 3 and 24 h post-injection. The radiolabeled species in the kidney at 24 h after the injection of new octreotide derivative represented 111 In-DTPA-D-Phe-OH and 111 In-DTPA-D-Phe-Asp-OH as the metabolites. Their radiometabolites and intact 111 In-DTPA-conjugated octreotide derivative were observed in urine within 24 h post-injection. Conclusion: The present study provided a new example of an 111 In-DTPA-conjugated octreotide derivative having the characteristics of both reduced renal uptake and shortened residence time of radioactivity in the kidney. It is considered that this kinetic control was achieved by introducing a negative charge on the octreotide derivative thereby suppressing the reabsorption in the renal tubules and affording the radiometabolites with appropriate lipophilicity.

  11. Indium-111 labeled purified granulocytes in the diagnosis of synthetic vascular graft infection

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Dewanjee, M.K.; Chowdhury, S.; Brown, M.L.

    1988-01-01

    Indium-111 labeled leukocytes have been shown to be useful in the diagnosis of synthetic vascular graft infection. To minimize the potential effects of labeled red blood cells and platelets on image interpretation, the authors prepared purified autologous granulocytes (PG) from 84 ml of blood using Volex enhanced gravity sedimentation and Ficoll-Hypaque double density centrifugation. The labeling efficiency of PG with In-111 tropolone was 90 +/- 9% (mean +/- SD). Imaging was performed 18-24 hours following injection of approximately 445 microcuries of In-111 PG in 26 patients with suspected infection of vascular grafts that had been implanted 12 days to 12 years prior to the study. In ten patients with proven graft infection, seven had positive In-111 PG scans. Ten of 11 patients without infection had negative scans. In five patients with clinically equivocal findings, scan results were positive in one, negative in one, and equivocal in three. A false-positive scan occurred in a patient with an uninfected inflammatory pseudoaneurysm of an aortic graft. These results confirm an earlier report that In-111 PG imaging is a useful technique in the diagnosis of synthetic vascular graft infection

  12. 21 CFR 111.13 - What supervisor requirements apply?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What supervisor requirements apply? 111.13 Section 111.13 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKAGING, LABELING...

  13. Alterations in an indium-111 Fab' under conditions of utilization

    International Nuclear Information System (INIS)

    Halpern, S.E.; Sudora, E.; Tarburton, J.P.; Hagar, P.

    1992-01-01

    This study was conducted to investigate alterations that occur in an indium/111 Fab' of a monoclonal antibody following its in vivo administration. Patients were infused with 111 In-Fab' of the monoclonal antibody ZCE-025. Serum and urine specimens were collected from these pateients. Starting materials, serum, urine and controls samples were studied by electrophoresis. Animal distribution studies were performed in normal Balb/c mice and, in some cases, nude mice bearing a carcinoembryonic antigen (CEA)/producing human colon tumour since the antibody targets CEA. The studies indicated that the molecule circulated almost totally intact for at least 4 h and to a considerable extent for 24 h, with some evidence for in vivo fragmentation by 24 h. Evidence was also obtained suggesting the formation of a high molecular weight species in some patients. Shortly after infusion, some of the 111 In in the urine appeared as the intact Fab', but within hours the majority migrated electro-phoretically as low molecular weight species. We conclude that while the majority of the 111 In-Fab' of this particular antibody remains intact and immunoreactive following its administration, the molecule is structurally changed to some degree shortly after its infusion into humans. Since each monoclonal antibody is unique, the degree and rapidity of degradation of its Fab' in vivo could vary markedly from the above and possibly adversely effect its utility as a radiopharmaceutical. (orig.)

  14. 46 CFR 111.95-7 - Wiring of boat winch components.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wiring of boat winch components. 111.95-7 Section 111.95... SYSTEMS-GENERAL REQUIREMENTS Electric Power-Operated Boat Winches § 111.95-7 Wiring of boat winch... electric installation from all sources of potential. The switch must be in series with and on the supply...

  15. 46 CFR 111.50-1 - Protection of equipment.

    Science.gov (United States)

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... electric equipment must meet the following listed subparts of this chapter: (a) Appliances, Subpart 111.77...) Transformers, Subpart 111.20. ...

  16. Energy-resolved attosecond interferometric photoemission from Ag(111) and Au(111) surfaces

    Science.gov (United States)

    Ambrosio, M. J.; Thumm, U.

    2018-04-01

    Photoelectron emission from solid surfaces induced by attosecond pulse trains into the electric field of delayed phase-coherent infrared (IR) pulses allows the surface-specific observation of energy-resolved electronic phase accumulations and photoemission delays. We quantum-mechanically modeled interferometric photoemission spectra from the (111) surfaces of Au and Ag, including background contributions from secondary electrons and direct emission by the IR pulse, and adjusted parameters of our model to energy-resolved photoelectron spectra recently measured at a synchrotron light source by Roth et al. [J. Electron Spectrosc. 224, 84 (2018), 10.1016/j.elspec.2017.05.008]. Our calculated spectra and photoelectron phase shifts are in fair agreement with the experimental data of Locher et al. [Optica 2, 405 (2015), 10.1364/OPTICA.2.000405]. Our model's not reproducing the measured energy-dependent oscillations of the Ag(111) photoemission phases may be interpreted as evidence for subtle band-structure effects on the final-state photoelectron-surface interaction not accounted for in our simulation.

  17. 29 CFR 780.111 - “Dairying” as a farming operation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false âDairyingâ as a farming operation. 780.111 Section 780.111... General Scope of Agriculture Dairying § 780.111 “Dairying” as a farming operation. “Dairying” includes the work of caring for and milking cows or goats. It also includes putting the milk in containers, cooling...

  18. 19 CFR 357.111 - Public and proprietary information.

    Science.gov (United States)

    2010-04-01

    ... conspicuously mark in the upper right corner of both versions, the words “proprietary document” or “public... 19 Customs Duties 3 2010-04-01 2010-04-01 false Public and proprietary information. 357.111 Section 357.111 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE SHORT SUPPLY...

  19. Colorectal carcinoma metastases: Detection with In-111-labeled monoclonal antibody CCR 086

    International Nuclear Information System (INIS)

    Abdel-Nabi, H.H.; Levine, G.; Lamki, L.M.; Murray, J.L.; Tauxe, W.N.; Shah, A.N.; Patt, Y.Z.; Doerr, R.J.; Klein, H.A.; Gona, J.

    1990-01-01

    A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses of 5 and 20 mg. Of 25 known lesions, 17 were detected (sensitivity, 68%). The smallest detected lesion in the lung was 1 cm and in the liver was 1.5 cm. The serum half-life of In-111-labeled CCR 086 MoAb was approximately 64 hours. The formation of human antimouse antibody (HAMA) was detected in the serum of four of five patients who received 20 mg of MoAb. No HAMAs were detected in four patients receiving 5 mg of MoAb. No side effects were encountered. Because of effective detection of liver and lung metastases with lower doses (5-20 mg) of CCR 086 conjugated with In-111, further investigations are warranted to assess clinical and therapeutic potentials of CCR 086 in the management of colorectal cancer

  20. Life span and tissue distribution of 111indium-labeled blood platelets in hypomagnesemic lambs

    International Nuclear Information System (INIS)

    Schneider, M.D.; Miller, J.K.; White, P.K.; Ramsey, N.

    1983-01-01

    Circulating platelets may be activated by exposed triple-helical collagen in atherosclerotic lesions in Mg-deficient ruminants. Autologous platelets, labeled in vitro with 111In and determined to be active, were injected into 5 hypomagnesemic and 3 control lambs fed semipurified diets with 100 or 2,000 mg of Mg/kg of feed for 3 months. During the first 68 hours, 111In concentrations were 11 times higher in packed cells than in plasma. Packed-cell 111In increased 60% during the first 2 hours, probably due to initial tissue sequestration and later release of labeled platelets. Thereafter, platelet half-life span averaged 60 and 63 hours for hypomagnesemic and control lambs. After 68 hours, lambs were injected with native vascular collagen fibrils at 500 micrograms/kg of body weight to initiate reversible platelet aggregation. Within 1 minute, 83% of packed-cell 111In disappeared from circulation. Thirty minutes later, the lambs were euthanatized and necropsied and in the lungs, liver, and spleen, 111In averaged 24%, 19%, and 9%, respectively, of 111In injected 68 hours earlier. Organ deposits were not affected by Mg intake, but 111In in the lungs was somewhat lower in 2 lambs injected with inactivated collagen. Pathologic changes induced by reversible platelet aggregation were compatible with right ventricular failure complicated by pulmonary edema, similar to changes in hypomagnesemic lambs that died spontaneously. Platelets in blood exposed to vascular lesions in hypomagnesemic ruminants could be a major mortality risk factor in grass tetany disease

  1. Radiolabeling of equine platelets in plasma with 111In-(2-mercaptopyridine-N-oxide) and their in vivo survival

    International Nuclear Information System (INIS)

    Coyne, C.P.; Kelly, A.B.; Hornof, W.J.; O'Brien, T.R.; Philp, M.S.; Lamb, J.F.

    1987-01-01

    A method is presented for the in vitro isolation and radiolabeling of equine platelets with the isotope indium 111 ( 111 In: half-life = 2.8 days, gamma = 173 keV, 89%; 247 keV, 94%). The technique described involves complexing 111 In with the lipid-soluble chelating agent, 2-mercaptopyridine-N-oxide (merc), in an aqueous medium. 111 In-merc platelet-labeling efficiencies in autologous plasma pretreated with or without ferric citrate reagent were 82 +/- 7% and 24 +/- 12%, respectively. Mean intravascular survivals of 111 In-merc-radiolabeled platelets in 8 healthy horses according to simple linear, exponential, mean, weighted-mean residual sum of squares analysis, and multiple-hit model were 5.5 +/- 0.49, 3.5 +/- 0.53, 4.5 +/- 0.18, 4.3 +/- 0.65, and 3.6 +/- 0.97 days, respectively

  2. Basic study of platelet labeling with 111In-oxine

    International Nuclear Information System (INIS)

    Yui, Tokuo; Uchida, Tatsumi; Matsuda, Shin; Muroi, Shuichi; Tanaka, Tetsugoro

    1981-01-01

    Indium-111-oxine has recently been suggested as a new isotopic labeling agent of platelets. In this paper, the results on the investigation of in vitro labeling of human platelets with In-111-oxine and those of platelet kinetics in rats are presented. Based on the findings of those studies, the protocol of human platelet labeling with In-111-oxine for clinical use was established. All operations should be carried out with sterile techniques at 20 - 25 0 C. 1) Forty four ml venous blood is drawn into a 50 ml polystyrene syringe containing 6 ml ACD-A. 2) The blood is transferred to a 50 ml tube and centrifuged at 300 g for 15 min. 3) Supernatant platelet rich plasma (PRP) is transferred to other 50 ml tube. Then, the pH is adjusted to 6.5 by addition of 1 ml ACD-A per 20 ml PRP. 4) Platelets are sedimented by centrifuging at 1,500 g for 15 min and resuspended in 3 ml ACD-A-saline solution (pH 6.5). 5) Three hundreds μCi of In-111-oxine is added to the platelet suspension. The mixture is incubated for 20 min at room temperature. 6) About 15 ml of the platelet poor autologous plasma (PPP) is added into the incubated mixture, followed by the sedimentation of labeled platelets (1,500 g, 15 min). 7) The labeled platelets are suspended in 10 ml PPP and the contaminating red cells are sedimented by centrifuging at 200 g for 5 min. 8) One hundred and fifty μCi of labeled platelet suspension is injected to the patient intravenously. The labeling efficiency in this method was 62 +- 5% (mean +- 1S.D., n = 6). (author)

  3. 111In-BnDTPA-F3: an Auger electron-emitting radiotherapeutic agent that targets nucleolin.

    Science.gov (United States)

    Cornelissen, Bart; Waller, Andrew; Target, Carol; Kersemans, Veerle; Smart, Sean; Vallis, Katherine A

    2012-02-20

    The F3 peptide (KDEPQRRSARLSAKPAPPKPEPKPKKAPAKK), a fragment of the human high mobility group protein 2, binds nucleolin. Nucleolin is expressed in the nuclei of normal cells but is also expressed on the membrane of some cancer cells. The goal was to investigate the use of 111In-labeled F3 peptide for Auger electron-targeted radiotherapy. F3 was labeled with fluorescein isothiocyanate (FITC) for confocal microscopy and conjugated to p-SCN-benzyl-diethylenetriaminepentaacetic acid (BnDTPA) for labeling with 111In to form 111In-BnDTPA-F3. MDA-MB-231-H2N (231-H2N) human breast cancer cells were exposed to 111In-BnDTPA-F3 and used in cell fractionation, γH2AX immunostaining (a marker of DNA double-strand breaks), and clonogenic assays. In vivo, biodistribution studies of 111In-BnDTPA-F3 were performed in 231-H2N xenograft-bearing mice. In tumor growth delay studies, 111In-BnDTPA-F3 (3 μg, 6 MBq/μg) was administered intravenously to 231-H2N xenograft-bearing mice once weekly for 3 weeks. Membrane-binding of FITC-F3 was observed in 231-H2N cells, and there was co-localization of FITC-F3 with nucleolin in the nuclei. After exposure of 231-H2N cells to 111In-BnDTPA-F3 for 2 h, 1.7% of 111In added to the medium was membrane-bound. Of the bound 111In, 15% was internalized, and of this, 37% was localized in the nucleus. Exposure of 231-H2N cells to 111In-BnDTPA-F3 (1 μM, 6 MBq/μg) resulted in a dose-dependent increase in γH2AX foci and in a significant reduction of clonogenic survival compared to untreated cells or cells exposed to unlabeled BnDTPA-F3 (46 ± 4.1%, 100 ± 1.8%, and 132 ± 7.7%, respectively). In vivo, tumor uptake of 111In-BnDTPA-F3 (3 μg, 6 MBq/μg) at 3-h post-injection was 1% of the injected dose per gram (%ID/g), and muscle uptake was 0.5%ID/g. In tumor growth delay studies, tumor growth rate was reduced 19-fold compared to untreated or unlabeled BnDTPA-F3-treated mice (p = 0.023). 111In-BnDTPA-F3 is internalized into 231-H2N cells and translocates

  4. Diagnosis of osteomyelitis of the foot in diabetic patients: Value of 111In-leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Larcos, G.; Brown, M.L.; Sutton, R.T.

    1991-01-01

    The noninvasive diagnosis of osteomyelitis of the foot in diabetic patients with currently available radiologic and radionuclide imaging techniques is often difficult. Recently, 111In-labeled leukocyte scintigraphy has been proposed as an attractive alternative. Accordingly, the authors retrospectively reviewed 51 111In-labeled leukocyte scans, 49 technetium-99m bone scans, and 49 plain radiographs obtained in 51 adults with diabetes in whom osteomyelitis of the foot was suspected. The sensitivity and specificity of these techniques were evaluated in all patients, as well as in a subgroup of 11 patients with neuroarthropathy. Results with 111In-labeled leukocyte scans were also examined in subsets of patients with soft-tissue ulcers (n = 35) and those receiving antibiotics during investigation (n = 20). Confirmation or exclusion of osteomyelitis was made surgically in 28 patients and clinically in 23. Fourteen patients had osteomyelitis. Bone scans were most sensitive (93%) but least specific (43%); plain radiographs were most specific (83%) but least sensitive (43%). 111In-labeled leukocyte scans were both sensitive (79%) and specific (78%), and remained useful in patients with neuroarthropathy, soft-tissue ulcers, and antibiotic treatment. Poor spatial resolution contributed to the false-negative and false-positive 111In-labeled leukocyte scans, suggesting that this technique should not be interpreted independent of other tests. 111In-labeled leukocyte scans are a valuable diagnostic tool for the diagnosis of pedal osteomyelitis in diabetic patients

  5. Comparative analysis of {sup 99m}Tc-MDP three-phase bone scan with SPECT/CT and {sup 99m}Tc-HMPAO-labeled WBC SPECT/CT in the differential diagnosis of clinically suspicious post-traumatic osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Chan Woo; Lee, Soo Jin; Kim, Ji Young; Hwang, Kyu Tae; Choi, Yun Young [Hanyang University Medical CenterSeoul (Korea, Republic of)

    2017-03-15

    To identify differences between three-phase bone scan and SPECT/CT (TBS) and WBC SPECT/CT (WS) and compare diagnostic accuracies of each modality in patients with suspicious post-traumatic osteomyelitis (OM). Twenty-one patients with suspicious post-traumatic OM were enrolled. All patients performed TBS and WS within 1 week. Foci of MDP and WBC accumulation were divided into three categories: bone (OM), soft tissue (soft tissue inflammation; STI), negative for inflammation (NI). Confirmative diagnosis was made upon operative pathology or long-term clinical follow-up. Of 21 patients, four OM, eight STI, nine NI were finally diagnosed. TBS diagnosis was correct in three of four positive cases and nine of 17 negative cases. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV) of TBS were 75 %, 52.9 %, 57.1 %, 27.3 %, 90 %. WS diagnosis was correct in two of four positive cases and 17 of 17 negative cases. Sensitivity, specificity, accuracy, PPV, NPV were 50 %, 100 %, 81.0 %, 100 %, 89.5 %. Twelve of 21 cases showed agreement between TBS and WS. TBS misdiagnosed nine cases (six STI and two NI as eight OM; one OM as one STI), while WS misdiagnosed four cases (two OM as two STI; two STI as two NI). Combining results from TBS and WS led to better diagnostic accuracy (91.7 %) than either TBS or WS alone. TBS and WS showed moderate agreement in assessment of clinically suspected post-traumatic OM. WS better evaluated inflammation than TBS. WS tended to underestimate inflammation whereas TBS tended to overestimate inflammation. Combining TBS and WS enhanced diagnostic accuracy.

  6. Reconstruction of alveolar defects in patients with cleft lip and palate - 111 consecutive patients

    DEFF Research Database (Denmark)

    Andersen, Kristian

    2012-01-01

    Reconstruction of alveolar defects in patients with cleft lip and palate - 111 consecutive patients......Reconstruction of alveolar defects in patients with cleft lip and palate - 111 consecutive patients...

  7. Indium-111 granulocyte scintigraphy in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Heresbach, D.; Darnault, P.; Bretagne, J.F.

    1996-01-01

    The present paper reports our experience since 1963 concerning 111-indium labeled autologous granulocytes scanning in the assessment of inflammatory bowel diseases and in the assessment of activity in Crohn's disease and ulcerative colitis. (authors). 94 refs., 3 figs

  8. Evaluation of /sup 111/In leukocyte whole body scanning

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-11-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with /sup 111/In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes.

  9. In situ STM imaging of the structures of pentacene molecules adsorbed on Au(111).

    Science.gov (United States)

    Pong, Ifan; Yau, Shuehlin; Huang, Peng-Yi; Chen, Ming-Chou; Hu, Tarng-Shiang; Yang, Yawchia; Lee, Yuh-Lang

    2009-09-01

    In situ scanning tunneling microscope (STM) was used to examine the spatial structures of pentacene molecules adsorbed onto a Au(111) single-crystal electrode from a benzene dosing solution containing 16-400 microM pentacene. Molecular-resolution STM imaging conducted in 0.1 M HClO(4) revealed highly ordered pentacene structures of ( radical31 x radical31)R8.9 degrees , (3 x 10), ( radical31 x 10), and ( radical7 x 2 radical7)R19.1 degrees adsorbed on the reconstructed Au(111) electrode dosed with different pentacene solutions. These pentacene structures and the reconstructed Au(111) substrate were stable between 0.2 and 0.8 V [vs reversible hydrogen electrode, RHE]. Increasing the potential to E > 0.8 V lifted the reconstructed Au(111) surface and disrupted the ordered pentacene adlattices simultaneously. Ordered pentacene structures could be restored by applying potentials negative enough to reinforce the reconstructed Au(111). At potentials negative of 0.2 V, the adsorption of protons became increasingly important to displace adsorbed pentacene admolecules. Although the reconstructed Au(111) structure was not essential to produce ordered pentacene adlayers, it seemed to help the adsorption of pentacene molecules in a long-range ordered pattern. At room temperature (25 degrees C), approximately 100 pentacene molecules seen in STM images could rotate and align themselves to a neighboring domain in 10 s, suggesting that pentacene admolecules could be mobile on Au(111) under the STM imaging conditions of -150 mV in bias voltage and 1 nA in feedback current.

  10. Lung perfusion scintigraphy in congenital heart disease

    International Nuclear Information System (INIS)

    Sugimura, Hiroshi; Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Oonishi, Takashi; Futami, Shigemi; Watanabe, Katsushi

    1990-01-01

    Lung perfusion scintigrams were reviewed retrospectively in 28 patients with congenital heart disease, whose ages ranged from the first year to 16 years with an average age of 5 years and 6 months. Seventy four MBq (2 mCi), 111 MBq (2 mCi), and 185 MBq (5 mCi) of Tc-99m macroaggregated albumin were iv injected in the age groups of 0-3, 4-11, and more than 11 years, respectively. Five minutes later, images were obtained in six projections. Abnormal findings on lung perfusion scintigrams were observed in 13 patients (46%). Of these patients, 8 (29%) had a partially decreased blood flow and 5 (17%) had a decreased blood flow in the unilateral lung. No significant difference in the occurrence of abnormal findings was observed among the age groups, although they tended to occur in younger patients. Sex, underlying conditions, and hemodynamics were also independent of scintigraphically abnormal findings. Even when classifying the patients as having either cyanotic or non-cyanotic heart disease, no significant difference in hemodynamics was observed between the group of abnormal findings and the group of normal findings. Pulmonary arteriography available in all patients failed to reveal abnormal findings, with the exception of pulmonary artery stenosis in 2 patients that corresponded to a decreased blood flow in the unilateral lung. Pulmonary artery stenosis seemed to be responsible for abnormal pulmonary blood flow, although other causes remained uncertain. (N.K.)

  11. Data Evaluation Acquired Talys 1.0 Code to Produce 111In from Various Accelerator-Based Reactions

    Science.gov (United States)

    Alipoor, Zahra; Gholamzadeh, Zohreh; Sadeghi, Mahdi; Seyyedi, Solaleh; Aref, Morteza

    The Indium-111 physical-decay parameters as a β-emitter radionuclide show some potential for radiodiagnostic and radiotherapeutic purposes. Medical investigators have shown that 111In is an important radionuclide for locating and imaging certain tumors, visualization of the lymphatic system and thousands of labeling reactions have been suggested. The TALYS 1.0 code was used here to calculate excitation functions of 112/114-118Sn+p, 110Cd+3He, 109Ag+3He, 111-114Cd+p, 110/111Cd+d, 109Ag+α to produce 111In using low and medium energy accelerators. Calculations were performed up to 200 MeV. Appropriate target thicknesses have been assumed based on energy loss calculations with the SRIM code. Theoretical integral yields for all the latter reactions were calculated. The TALYS 1.0 code predicts that the production of a few curies of 111In is feasible using a target of isotopically highly enriched 112Cd and a proton energy between 12 and 25 MeV with a production rate as 248.97 MBq·μA-1 · h-1. Minimum impurities shall be produced during the proton irradiation of an enriched 111Cd target yielding a production rate for 111In of 67.52 MBq· μA-1 · h-1.

  12. 46 CFR 111.20-15 - Protection of transformers against overcurrent.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of transformers against overcurrent. 111.20-15 Section 111.20-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Transformer Construction, Installation, and Protection § 111...

  13. Indium-111 labelled platelets: experimental and clinical studies

    International Nuclear Information System (INIS)

    Gjerloeff Schmidt, K.

    1985-10-01

    The object of the present study became to develop a method of effective and gentle isolation and 111-In labelling of human platelets, as well as to employ these platelets in human clinical studies with the object of elucidating a number of physiological and pathophysiological mechanisms and processes in which platelets take part. 111-In-oxine presents obvious advantages over 51-Cr-sodium chromate; a high labelling efficiency, and more advantageous physical properties (a half life of 68 hours (against the half life of 28 days for 51-Cr) and considerably more effective gamma emission), making external registration by means of a gamma camera possible. Considering the role played by platelets in the development of atherosclerosis and its thromboembolic complications, in the early phases of deep venous thrombosis, and in graft rejection, it is natural that attempts have been made to use 111-In-labelled platelets for scintigraphic and kinetic evaluation of thromboembolic processes. Accumulation of 111-In-labelled platelets at sites of vessel wall injury, on pulmonary emboli (presumably on deep vein thrombi as well), and on catheter material has been demonstrated. Beyond this, the number of publications concerning the use of 111-In-labelled platelets for visualization of atherosclerosis, venous thromboembolism, arterial grafts, intracardiac thrombi, aortic aneurysms, renal allograft rejection, and other situations in which platelet thromboembolism takes place, provides evidence that a tool has finally been found for the study of their nature and response to therapeutic intervention. (eg)

  14. Osseous sarcoidosis. A case report with scintigraphic consideration

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, H; Miyamura, T; Okumura, T; Yamamoto, I; Nishiki, T [Kanazawa Medical Univ., Ishikawa (Japan)

    1981-12-01

    We presented a case of osseous sarcoidosis which demonstrated abnormal uptake on bone scintigram and /sup 67/Ga scintigram and comparative studies between routine radiographs of bone and RI imagings were done. The results showed that bone scintigram is more sensitive than routine radiographs and it was stressed that bone scintigram should precede radiographic skeletal survey. The significance of abnormal uptake on /sup 67/Ga scintigram seems to need further investigation.

  15. A novel method for selective separation of {sup 111}In from impurities by ion exchange chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yavari, R.; Khanachi, A.R.; Ghannad Maragheh, M.; Bagheri, G. [Jaber Ibn-e Hayan Research Laboratories, A.E.O.I., Tehran (Iran)

    2004-07-01

    {sup 111}In is one of the most important cyclotron-produced radionuclides that is prepared from nuclear reactions like Cd (p,xn){sup 111}In and Cd (d,xn) {sup 111}In. It is used in various branches of medicine such as lymphoscintigraphy and cisternography. Several methods have been reported in the literature for the separation of carrier-free {sup 111}In from irradiated cadmium matrix. But there has not been a sufficiently fast method for this purpose until recently. In this work, a new method has been developed for the separation of {sup 111}In from a cadmium target by using Dowex 50W-X8 as an ion exchanger. (orig.)

  16. Interaction of Se and GaSe with Si(111)

    International Nuclear Information System (INIS)

    Meng, Shuang; Schroeder, B. R.; Olmstead, Marjorie A.

    2000-01-01

    Deposition of Se and GaSe on Si(111)7x7 surfaces was studied with low-energy electron diffraction, x-ray photoelectron spectroscopy, and x-ray photoelectron diffraction to probe initial nucleation and interface structure for GaSe/Si(111) heteroepitaxy. Room-temperature deposition of Se on Si(111)7x7 results in an amorphous film. Subsequent annealing leads to Se evaporation without ordering or interdiffusion. Se deposition at 450 degree sign C saturates at submonolayer coverage with no diffusion of Se into the substrate. There is no clear evidence of ordered sites for the Se. Growth of GaSe on Si(111)7x7 above 500 degree sign C results in a pseudomorphic bilayer, with Si-Ga-Se bonding. Additional GaSe does not stick to the bilayer above 525 degree sign C. The resulting Se lone pair at the surface leads to an ideally passivated surface similar to As/Si(111). This stable surface is similar to the layer termination in bulk GaSe. The single domain bilayer is oriented with the Ga-Se bond parallel to the substrate Si-Si bond. (c) 2000 The American Physical Society

  17. Silicon and Germanium (111) Surface Reconstruction

    Science.gov (United States)

    Hao, You Gong

    Silicon (111) surface (7 x 7) reconstruction has been a long standing puzzle. For the last twenty years, various models were put forward to explain this reconstruction, but so far the problem still remains unsolved. Recent ion scattering and channeling (ISC), scanning tunneling microscopy (STM) and transmission electron diffraction (TED) experiments reveal some new results about the surface which greatly help investigators to establish better models. This work proposes a silicon (111) surface reconstruction mechanism, the raising and lowering mechanism which leads to benzene -like ring and flower (raised atom) building units. Based on these building units a (7 x 7) model is proposed, which is capable of explaining the STM and ISC experiment and several others. Furthermore the building units of the model can be used naturally to account for the germanium (111) surface c(2 x 8) reconstruction and other observed structures including (2 x 2), (5 x 5) and (7 x 7) for germanium as well as the (/3 x /3)R30 and (/19 x /19)R23.5 impurity induced structures for silicon, and the higher temperature disordered (1 x 1) structure for silicon. The model is closely related to the silicon (111) surface (2 x 1) reconstruction pi-bonded chain model, which is the most successful model for the reconstruction now. This provides an explanation for the rather low conversion temperature (560K) of the (2 x 1) to the (7 x 7). The model seems to meet some problems in the explanation of the TED result, which is explained very well by the dimer, adatom and stacking fault (DAS) model proposed by Takayanagi. In order to explain the TED result, a variation of the atomic scattering factor is proposed. Comparing the benzene-like ring model with the DAS model, the former needs more work to explain the TED result and the later has to find a way to explain the silicon (111) surface (1 x 1) disorder experiment.

  18. 46 CFR 221.111 - Status of prior transactions-controlling dates.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Status of prior transactions-controlling dates. 221.111 Section 221.111 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION REGULATIONS AFFECTING... MARITIME INTERESTS Savings Provisions § 221.111 Status of prior transactions—controlling dates. (a) The...

  19. New bonding configuration on Si(111) and Ge(111) surfaces induced by the adsorption of alkali metals

    DEFF Research Database (Denmark)

    Lottermoser, L.; Landemark, E.; Smilgies, D.M.

    1998-01-01

    The structure of the (3×1) reconstructions of the Si(111) and Ge(111) surfaces induced by adsorption of alkali metals has been determined on the basis of surface x-ray diffraction and low-energy electron diffraction measurements and density functional theory. The (3×1) surface results primarily f...... from the substrate reconstruction and shows a new bonding configuration consisting of consecutive fivefold and sixfold Si (Ge) rings in 〈11̅ 0〉 projection separated by channels containing the alkali metal atoms. © 1998 The American Physical Society...

  20. Dual isotope study of iodine-125 and indium-111-labeled antibody in athymic mice

    Energy Technology Data Exchange (ETDEWEB)

    Carney, P.L.; Rogers, P.E.; Johnson, D.K. (Abbott Laboratories, Abbott Park, IL (USA))

    1989-03-01

    Monoclonal antibody B72.3 was coupled to a benzylisothiocyanate derivative of diethylenetriaminepentaacetic acid (DTPA). The maximum substitution achievable without loss of immunoreactivity was three DTPA groups per immunoglobulin molecule. The resulting conjugate was labeled with {sup 111}In by brief incubation with {sup 111}InCl{sub 3}, giving a mean radiochemical yield of {sup 111}In-labeled antibody of 96%. The ({sup 111}In)B72.3 preparation was mixed with an ({sup 125}I) B72.3 preparation, obtained by the chloramine-T method, and the mixture administered to athymic mice bearing subcutaneous LS174T colon carcinoma xenografts. There were no significant differences (p greater than 0.1) in the biodistributions of the two labels at 1, 2, 5, and 7 days postinjection. These results are contrasted with prior studies showing elevated levels of {sup 111}In in liver, spleen, and kidneys using B72.3-DTPA conjugates prepared via the bicyclic anhydride. It is concluded that protein cross-linking and/or the formation of unstable chelate sites in anhydride coupled conjugates underlie these disparities.

  1. Dual isotope study of iodine-125 and indium-111-labeled antibody in athymic mice

    International Nuclear Information System (INIS)

    Carney, P.L.; Rogers, P.E.; Johnson, D.K.

    1989-01-01

    Monoclonal antibody B72.3 was coupled to a benzylisothiocyanate derivative of diethylenetriaminepentaacetic acid (DTPA). The maximum substitution achievable without loss of immunoreactivity was three DTPA groups per immunoglobulin molecule. The resulting conjugate was labeled with 111 In by brief incubation with 111 InCl 3 , giving a mean radiochemical yield of 111 In-labeled antibody of 96%. The [ 111 In]B72.3 preparation was mixed with an [ 125 I] B72.3 preparation, obtained by the chloramine-T method, and the mixture administered to athymic mice bearing subcutaneous LS174T colon carcinoma xenografts. There were no significant differences (p greater than 0.1) in the biodistributions of the two labels at 1, 2, 5, and 7 days postinjection. These results are contrasted with prior studies showing elevated levels of 111 In in liver, spleen, and kidneys using B72.3-DTPA conjugates prepared via the bicyclic anhydride. It is concluded that protein cross-linking and/or the formation of unstable chelate sites in anhydride coupled conjugates underlie these disparities

  2. Diagnosis of protein-losing gastroenteropathy by sup 111 In-transferrin scanning and fecal excretion test

    Energy Technology Data Exchange (ETDEWEB)

    Urita, Yoshihisa (Toho Univ., Tokyo (Japan). School of Medicine)

    1991-10-01

    A total of 12 patients with gastroenteropathy were studied for possible protein loss. The underlying diseases were intestinal lymphangiectasia, ulcerative colitis and Crohn's disease in 2 patients each and Menetrier's disease, Cronkhite-Canada syndrome, postgastrectomy syndrome, severe atrophic gastritis, gastric cancer and gastroenteropathy of unknown origin in one patient each. The controls were four healthy volunteers and 9 patients with benign disease not accompanied by lesions in the digestive tract and protein loss {sup 111}In-transferrin Tf was prepared by incubating 2-3 mCi of {sup 111}In-chloride with 15-20 ml of each patient's plasma in a sterilized vial at room temperature for 1 hour. After iv injection of {sup 111}In-Tf the patients were scanned at given intervals of time for 72 hours to localize protein loss. Seventy-two hour fecal {sup 111}In-Tf excretion was also measured. {sup 111}In-Tf was detected in the feces of all patients. The recovery rate in the patient group was 7.95{+-}3.65%, being significantly higher than 0.48{+-}0.26% in the control group. However {sup 111}In-Tf scanning showed the site of protein loss only in 6 patients. Negative scan in six other patients was thought to be associated with extensive inflammation and severe diarrhea. Five of the 12 patients were observed before and after treatment. A decrease in fecal {sup 111}In-Tf excretion with clinical improvement was noted in the 5 patients after treatment. The site of protein loss could be demonstrated in 3 of the 5 patients before treatment. Its site in 1 of the 3 patients was the small intestine. However accumulation of {sup 111}In-Tf was found there in the 3 patients after treatment. The site of protein loss in 1 of 3 patients was the small intestine. {sup 111}In-Tf scanning is particularly useful when the small intestine is involved, because surgery is contraindicated in this case. Fecal {sup 111}In-Tf excretion test is mandatory when the site of protein loss

  3. Biodistribution parameters and radiation absorbed dose estimates for radiolabeled human low density lipoprotein

    International Nuclear Information System (INIS)

    Hay, R.V.; Ryan, J.W.; Williams, K.A.; Atcher, R.W.; Brechbiel, M.W.; Gansow, O.A.; Fleming, R.M.; Stark, V.J.; Lathrop, K.A.; Harper, P.V.

    1992-01-01

    The authors propose a model to generate radiation absorbed dose estimates for radiolabeled low density lipoprotein (LDL), based upon eight studies of LDL biodistribution in three adult human subjects. Autologous plasma LDL was labeled with Tc-99m, I-123, or In-111 and injected intravenously. Biodistribution of each LDL derivative was monitored by quantitative analysis of scintigrams and direct counting of excreta and of serial blood samples. Assuming that transhepatic flux accounts for the majority of LDL clearance from the bloodstream, they obtained values of cumulated activity (A) and of mean dose per unit administered activity (D) for each study. In each case highest D values were calculated for liver, with mean doses of 5 rads estimated at injected activities of 27 mCi, 9 mCi, and 0.9 mCi for Tc-99m-LDL, I-123-LDL, and In-111-LDL, respectively

  4. Kinetics and biodistribution of In-111 platelets in patients with bone marrow transplants, refractory to platelet transfusions

    International Nuclear Information System (INIS)

    Civelek, C.; Braine, H.; Scheffel, U.; Drew, H.; Koester, A.; LaFrance, N.; Kasecamp, W.; Wagner, H. Jr.

    1984-01-01

    The kinetics and biodistribution of HLA identical In-111 labeled platelets was studied in 10 leukemic patients with bone marrow transplants refractory to HLA matched platelet transfusions. Platelet survival time was short (x-bar +- SEM =1.64 +- 0.83 days). The mean recovery (extrapolated to zero time) was 29.9%, ranging from 14.2 to 63.0%. The deposition of the In-111 platelets in the liver and spleen was quantified by the geometric mean method using anterior and posterior imaging. In 3 patients liver uptake was significantly increased. The highest hepatic accumulation of In-111 occurred 2 hrs after injection (x-bar=76 +- 6% dose (SEM); at 48 hrs 62% of the dose remained in the liver. In 7 patients the spleen was the organ with the highest labeled platelet deposition. The splenic uptake of In-111 platelets in this group correlated with the spleen size (r=+0.95). At 30 min after injection 75+-6% of the dose was found in the spleen. Splenic activity decreased to 62% after 48 hrs. At the same time, In-111 liver accumulation increased from 14 to 31%. This finding suggests that In-111 may be released from the spleen and subsequently sequestered by the liver. Two patients with high splenic uptake underwent splenectomy after the In-111 platelet study. Both benefited from splenectomy in terms of platelet survival after transfusion

  5. Kinetics and biodistribution of In-111 platelets in patients with bone marrow transplants, refractory to platelet transfusions

    Energy Technology Data Exchange (ETDEWEB)

    Civelek, C.; Braine, H.; Scheffel, U.; Drew, H.; Koester, A.; LaFrance, N.; Kasecamp, W.; Wagner, H. Jr.

    1984-01-01

    The kinetics and biodistribution of HLA identical In-111 labeled platelets was studied in 10 leukemic patients with bone marrow transplants refractory to HLA matched platelet transfusions. Platelet survival time was short (x-bar +- SEM =1.64 +- 0.83 days). The mean recovery (extrapolated to zero time) was 29.9%, ranging from 14.2 to 63.0%. The deposition of the In-111 platelets in the liver and spleen was quantified by the geometric mean method using anterior and posterior imaging. In 3 patients liver uptake was significantly increased. The highest hepatic accumulation of In-111 occurred 2 hrs after injection (x-bar=76 +- 6% dose (SEM); at 48 hrs 62% of the dose remained in the liver. In 7 patients the spleen was the organ with the highest labeled platelet deposition. The splenic uptake of In-111 platelets in this group correlated with the spleen size (r=+0.95). At 30 min after injection 75+-6% of the dose was found in the spleen. Splenic activity decreased to 62% after 48 hrs. At the same time, In-111 liver accumulation increased from 14 to 31%. This finding suggests that In-111 may be released from the spleen and subsequently sequestered by the liver. Two patients with high splenic uptake underwent splenectomy after the In-111 platelet study. Both benefited from splenectomy in terms of platelet survival after transfusion.

  6. Gas-source molecular beam epitaxy of Si(111) on Si(110) substrates by insertion of 3C-SiC(111) interlayer for hybrid orientation technology

    Energy Technology Data Exchange (ETDEWEB)

    Bantaculo, Rolando, E-mail: rolandobantaculo@yahoo.com; Saitoh, Eiji; Miyamoto, Yu; Handa, Hiroyuki; Suemitsu, Maki

    2011-11-01

    A method to realize a novel hybrid orientations of Si surfaces, Si(111) on Si(110), has been developed by use of a Si(111)/3C-SiC(111)/Si(110) trilayer structure. This technology allows us to use the Si(111) portion for the n-type and the Si(110) portion for the p-type channels, providing a solution to the current drive imbalance between the two channels confronted in Si(100)-based complementary metal oxide semiconductor (CMOS) technology. The central idea is to use a rotated heteroepitaxy of 3C-SiC(111) on Si(110) substrate, which occurs when a 3C-SiC film is grown under certain growth conditions. Monomethylsilane (SiH{sub 3}-CH{sub 3}) gas-source molecular beam epitaxy (GSMBE) is used for this 3C-SiC interlayer formation while disilane (Si{sub 2}H{sub 6}) is used for the top Si(111) layer formation. Though the film quality of the Si epilayer leaves a lot of room for betterment, the present results may suffice to prove its potential as a new technology to be used in the next generation CMOS devices.

  7. 111In-labeled lactam bridge-cyclized alpha-melanocyte stimulating hormone peptide analogues for melanoma imaging.

    Science.gov (United States)

    Miao, Yubin; Gallazzi, Fabio; Guo, Haixun; Quinn, Thomas P

    2008-02-01

    The purpose of this study was to examine the influence of the lactam bridge cyclization on melanoma targeting and biodistribution properties of the radiolabeled conjugates. Two novel lactam bridge-cyclized alpha-MSH peptide analogues, DOTA-CycMSH (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-c[Lys-Nle-Glu-His-DPhe-Arg-Trp-Gly-Arg-Pro-Val-Asp]) and DOTA-GlyGlu-CycMSH (DOTA-Gly-Glu-c[Lys-Nle-Glu-His-DPhe-Arg-Trp-Gly-Arg-Pro-Val-Asp]), were synthesized and radiolabeled with (111)In. The internalization and efflux of (111)In-labeled CycMSH peptides were examined in B16/F1 melanoma cells. The melanoma targeting properties, pharmacokinetics, and SPECT/CT imaging of (111)In-labeled CycMSH peptides were determined in B16/F1 melanoma-bearing C57 mice. Both (111)In-DOTA-CycMSH and (111)In-DOTA-GlyGlu-CycMSH exhibited fast internalization and extended retention in B16/F1 cells. The tumor uptake values of (111)In-DOTA-CycMSH and (111)In-DOTA-GlyGlu-CycMSH were 9.53+/-1.41% injected dose/gram (% ID/g) and 10.40+/-1.40% ID/g at 2 h postinjection, respectively. Flank melanoma tumors were clearly visualized with (111)In-DOTA-CycMSH and (111)In-DOTA-GlyGlu-CycMSH by SPECT/CT images at 2 h postinjection. Whole-body clearance of the peptides was fast, with greater than 90% of the radioactivities cleared through urinary system by 2 h postinjection. There was low radioactivity (<0.8% ID/g) accumulated in blood and normal organs except kidneys at all time points investigated. Introduction of a negatively charged linker (-Gly-Glu-) into the peptide sequence decreased the renal uptake by 44% without affecting the tumor uptake at 4 h postinjection. High receptor-mediated melanoma uptakes coupled with fast whole-body clearance in B16/F1 melanoma-bearing C57 mice demonstrated the feasibility of using (111)In-labeled lactam bridge-cyclized alpha-MSH peptide analogues as a novel class of imaging probes for receptor-targeting melanoma imaging.

  8. Correlation of bone scintigraphy findings and tumor markers during follow-up prostate cancer

    International Nuclear Information System (INIS)

    Aizawa, Taku

    1996-01-01

    In the last 9 years, 217 patients with prostate cancer were treated at our department. Of these patients 153 cases treated by estrogen therapy were followed up by bone scintigraphy and tumor marker examinations (prostate specific antigen [PSA], prostate acid phosphatase [PAP], gamma-seminoprotein [γ-SM) . The correlation between changes on bone scintigrams and synchronous changes in tumor markers was evaluated retrospectively. In cases in which bone metastasis was not recognized on bone scintigrams before treatment, changes of tumor markers corresponded with subsequent changes on bone scintigrams in more than 90%. However, in cases with bone metastasis on bone scintigrams before treatment, changes of bone scintigrams and changes of tumor markers corresponded in only 55% of cases. Changes of bone scintigrams do not always correspond with changes of tumor markers. However, by taking into consideration physical examination parameters such as bone pain, in addition to changes of tumor markers, most changes on bone scintigrams can be anticipated. The reasons for lack of correspondence between changes of bone scintigrams and changes of tumor markers may be, changes of tumor markers are more rapid than the changes on bone scintigram, some poorly differentiated cancers do not have increased tumor marker levels and bone scintigrams do not demonstrate soft tissue involvement. In the follow-up of patients with prostate cancer, it is not necessary to perform bone scintigraphy regularly at 3-month intervals. Bone scintigraphy should only be performed when serum levels of tumor markers increase or bone pain appears. (author)

  9. A novel statistical analysis method to improve the detection of hepatic foci of {sup 111}In-octreotide in SPECT/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Magnander, Tobias [Department of Radiation Physics, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden); Wikberg, E. [Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden); Svensson, J. [Department of Oncology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Gjertsson, P. [Department of Clinical Physiology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Wängberg, B. [Department of Surgery, The Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Båth, M.; Bernhardt, Peter [Department of Radiation Physics, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2016-01-19

    Low uptake ratios, high noise, poor resolution, and low contrast all combine to make the detection of neuroendocrine liver tumours by {sup 111}In-octreotide single photon emission tomography (SPECT) imaging a challenge. The aim of this study was to develop a segmentation analysis method that could improve the accuracy of hepatic neuroendocrine tumour detection. Our novel segmentation was benchmarked by a retrospective analysis of patients categorized as either {sup 111}In-octreotide positive ({sup 111}In-octreotide(+)) or {sup 111}In-octreotide negative ({sup 111}In-octreotide(−)) for liver tumours. Following a 3-year follow-up period, involving multiple imaging modalities, we further segregated {sup 111}In-octreotide-negative patients into two groups: one with no confirmed liver tumours ({sup 111}In-octreotide(−)/radtech(−)) and the other, now diagnosed with liver tumours ({sup 111}In-octreotide(−)/radtech(+)). We retrospectively applied our segmentation analysis to see if it could have detected these previously missed tumours using {sup 111}In-octreotide. Our methodology subdivided the liver and determined normalized numbers of uptake foci (nNUF), at various threshold values, using a connected-component labelling algorithm. Plots of nNUF against the threshold index (ThI) were generated. ThI was defined as follows: ThI = (c{sub max} − c{sub thr})/c{sub max}, where c{sub max} is the maximal threshold value for obtaining at least one, two voxel sized, uptake focus; c{sub thr} is the voxel threshold value. The maximal divergence between the nNUF values for {sup 111}In-octreotide(−)/radtech(−), and {sup 111}In-octreotide(+) livers, was used as the optimal nNUF value for tumour detection. We also corrected for any influence of the mean activity concentration on ThI. The nNUF versus ThI method (nNUFTI) was then used to reanalyze the {sup 111}In-octreotide(−)/radtech(−) and {sup 111}In-octreotide(−)/radtech(+) groups. Of a total of 53 {sup 111}In

  10. Hyperfine interactions in 111Cd-doped lutetium sesquioxide

    International Nuclear Information System (INIS)

    Errico, L.A.; Renteria, M.; Bibiloni, A.G.; Requejo, F.G.

    1999-01-01

    We report here first Perturbed Angular Correlation (PAC) results of the electric field gradient (EFG) characterisation at 111 Cd impurities located at both non-equivalent cation sites of the bixbyite structure of Lutetium sesquioxide, between room temperature (RT) and 1273 K. The comparison with results coming from a systematic 111 Cd PAC study in bixbyites and with point-charge model (PCM) predictions shows the presence of a trapped defect at RT in the neighbourhood of the asymmetric cation site, which is completely removed at T > 623 K. The anomalous EFG temperature dependence in Lu 2 O 3 can be described in the frame of a 'two-state' model with fluctuating interactions, which enables the experimental determination of the acceptor energy level introduced by the Cd impurity in the band-gap of the semiconductor and the estimation of the oxygen vacancy density in the sample

  11. Kinetic study of indium-111 labelled platelets in idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Reiffers, J.; Vuillemin, L.; Broustet, A.; Ducassou, D.

    1982-01-01

    Labelling platelets with 111 Indium-oxine has advantages over the conventional 51 chromium method: labelling is more efficient and the radiations emitted almost exclusively consist of gamma-rays. Owing to these advantages, autologous platelets can be used for kinetic studies in patients with idiopathic thrombocytopenic purpura, even when thrombocytopenia is severe. 111 Indium labelling also provides accurate information on the sites of platelet destruction, which may help to predict the patient's response to splenectomy [fr

  12. Iliac artery mural thrombus formation. Effect of antiplatelet therapy on 111In-platelet deposition in baboons

    International Nuclear Information System (INIS)

    Hanson, S.R.; Paxton, L.D.; Harker, L.A.

    1986-01-01

    To measure the rate, extent, and time course of arterial mural thrombus formation in vivo and to assess the effects of antiplatelet therapy in that setting, we have studied autologous 111 In-platelet deposition induced by experimental iliac artery aneurysms in baboons. Scintillation camera imaging analyses were performed at 1, 24, 48, and 72 hours after implantation of the device. Correction for tissue attenuation was determined by using a small, comparably located 111 In source implanted at the time of surgery. In five animals, 111 In-platelet activity accumulated progressively after device implantation, reaching a maximum after the third day. Repeat image analysis carried out 2 weeks after the surgical procedure also showed progressive accumulation of 111 In-platelets over 3 days but at markedly reduced amounts as compared with the initial study. In five additional animals, treatment with a combination of aspirin and dipyridamole begun 1 hour after surgical implantation reduced 111 In-platelet deposition to negligible levels by the third day. Although platelet survival time was shortened and platelet turnover was reciprocally increased in all operated animals, platelet survival and turnover were not affected by antiplatelet therapy. We conclude that, in contrast to platelet survival and turnover measurements, 111 In-platelet imaging is a reliable and sensitive method for localizing and quantifying focal arterial thrombi and for assessing the effects of antiplatelet therapy

  13. Methanol adsorption on Pt(111)

    International Nuclear Information System (INIS)

    Melo, A.V.; Chottiner, G.S.; Hoffman, R.W.; O'Grady, W.E.

    1984-12-01

    High resolution electron energy loss spectroscopy has been used to study the decomposition of methanol on a Pt(111) surface. Several intermediate states in the decomposition are identified by quenching the sample when reactions occur. At 100 K a set of peaks at 800, 1040, 1350, and 2890 cm -1 indicates the presence of a multilayer molecularly adsorbed methanol. As the sample is warmed to 130 K peaks develop at 1700 and 2780 cm -1 , suggesting the formation of formaldehyde on the surface. With further heating, peaks grow at 1820 and 2560 cm -1 due to the formation of a formyl species during the decomposition of methanol over Pt(111). Further heating leads to the final conversion of the surface species to adsorbed CO and carbonaceous residues

  14. New bands and spin-parity assignments in 111Ru

    International Nuclear Information System (INIS)

    Urban, W.; Rzaca-Urban, T.; Droste, C.; Rohozinski, S.G.; Durell, J.L.; Phillips, W.R.; Smith, A.G.; Varley, B.J.; Schulz, N.; Ahmad, I.; Pinston, J.A.

    2004-01-01

    The 111 Ru nucleus, populated in the spontaneous fission of 248 Cm has been studied by means of prompt gamma spectroscopy using the EUROGAM2 array. Spin and parity assignments, based on angular correlations, linear polarization, and conversion coefficient measurements differ from those available in the literature. New bands are reported, which incorporate γ transitions seen previously but not placed in the scheme of 111 Ru or placed incorrectly. The bands are interpreted as neutron excitations into subshells originating predominantly from the h 11/2 , g 7/2 and s 1/2 spherical orbitals. The s 1/2 band, strongly mixed with the d 3/2 , d 5/2 and g 7/2 configurations, is observed for the first time in this region. (orig.)

  15. In-111-labeled leukocytes in the diagnosis of rejection and cytomegalovirus infection in renal transplant patients

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Loken, M.K.; Cook, A.; Chandler, R.; McCullough, J.

    1981-01-01

    Indium-111-labeled (In-111) leukocytes have been shown to be useful in the localization of inflammatory processes, including renal transplant rejection. Using previously reported labeling methods, 63 studies with this agent have been performed in 53 renal transplant patients. Indications for study included suspected rejection or cytomegalovirus (CMV) infection. Studies were performed in 33 men and 20 women, with ages ranging from 6 to 68 years. Autologous cells were normally used for labeling, although leukocytes obtained from ABO-compatible donors were used in three subjects. Rectilinear scanner and/or scintillation camera images were obtained at 24 hours after intravenous administration of 0.1 to 0.6 mCi of In-111-leukocytes. There was abnormal uptake of In-111-leukocytes in the transplanted kidney in 11 of 15 cases of rejection. In three additional cases of increased transplant uptake, CMV infection was present in two. Abnormal lung uptake was present in 13 of 14 patients with CMV infection. In four additional cases, increased lung uptake was associated with other pulmonary inflammatory disease. Increased lung activity was not seen in patients with uncomplicated transplant rejection. These results suggest that In-111-leukocyte imaging may be useful in the differential diagnosis of rejection versus CMV infection in renal transplant patients

  16. In-111-labeled leukocytes in the diagnosis of rejection and cytomegalovirus infection in renal transplant patients

    International Nuclear Information System (INIS)

    Forstrom, L.A.; Loken, M.K.; Cook, A.; Chandler, R.; McCullough, J.

    1981-01-01

    Indium-111-labelled (In-111) leukocytes have been shown to be useful in the localization of inflammatory processes, including renal transplant rejection. Using previously reported labelling methods, 63 studies with this agent have been performed in 53 renal transplant patients. Indications for study included suspected rejection or cytomegalovirus (CMV) infection. Studies were performed in 33 men and 20 women, with ages ranging from 6 to 68 years. Autologous cells were normally used for labeling, although leukocytes obtained from ABO-compatible donors were used in three subjects. Rectilinear scanner and/or scintillation camera images were obtained at 24 hours after intravenous administration of 0.1 to 0.6 mCi of In-111 leukocytes. There was abnormal uptake of In-111-leukocytes in the transplanted kidney in 11 of 15 cases of rejection. In three additional cases of increased transplant uptake, CMV infection was present in two. Abnormal lung uptake was present in 13 of 14 patients with CMV infection. In four additional cases, increased lung uptake was associated with other pulmonary inflammatory disease. Increased lung activity was not seen in patients with uncomplicated transplant rejection. These results suggest that In-111-leukocyte imaging may be useful in the differential diagnosis of rejection versus CMV infection in renal transplant patients

  17. Measurement of renal function with /sup 111/In-DTPA in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Saha, G B [Arkansas Univ., Little Rock (USA). Medical Center; Farrer, P A

    1977-07-01

    The renal clearances of /sup 111/In-DTPA were measured and compared with those of /sup 125/I-iothalamate in dogs using three methods: (a) constant infusion method, (b) single injection UV/P method, and (c) single injection slope method. The renal clearances of /sup 111/In-DTPA were on the average 9% higher than those of /sup 125/I-iothalamate. Its urinary excretion was approximately 50% at 1 hr and about 80% at 4 hr, and biliary excretion was negligible. Sequential scintiphotography of the renal system in dogs revealed the flow of the tracer through the kidneys, and excretion into the ureter and bladder.

  18. First principles-based adsorption comparison of group IV elements (C, Si, Ge, and Sn) on Au(111)/Ag(111) surface

    International Nuclear Information System (INIS)

    Chakraborty, Sudip; Rajesh, Ch.

    2012-01-01

    We have reported a first-principle investigation of the structural properties of monomer and dimer for group IV elements (C, Si, Ge, and Sn) adsorbed on the Au(111) and Ag(111) surfaces. The calculations were performed by means of a plane wave based pseudopotential method under the framework of density functional theory. The results reveal the preference of adatom to be adsorbed on the hexagonal closed packed site of the metal (111) surfaces with strong binding energy. The structures introduce interlayer forces in the adsorbate. The strong bonding with the surface atoms is a result of p–d hybridization. The adsorption energy follows a sequence as one goes down in the group IV elements which imply that the interaction of the group IV elements with Au/Ag is decreasing as the atomic number increases.

  19. Scintigraphy of the bone marrow with 111In-citrin in polycythemia vera

    International Nuclear Information System (INIS)

    Prikhod'ko, A.G.; Sheptun, A.N.; Vikman, Ya.Eh.; Sorokin, I.N.; Rozdil'skij, S.I.; Zabobonina, L.V.

    1986-01-01

    Scintigraphy of the bone marrow with 111 In-citrin was performed in 32 patients with polycythemia vera and 8 controls. The method ensured an objective assessment of bone marrow function in patients with polycythemia vera. A characteristic RP scintigraphic picture corresponded to different clinical stages of the disease. A degree of a decrease in the blood radioactivity within 24 h after i.v. administration of 111 In-citrin reflected the summary erythropoietic activity of the bone marrow and could serve as a differential diagnostic criterion in determining a stage of polycythemia vera

  20. 99Tcsup(m)-HMPAO labelled leucocytes: comparison with 111In-tropolonate labelled granulocytes

    International Nuclear Information System (INIS)

    Peters, A.M.; Roddie, M.E.; Zacharopoulos, G.P.; George, P.; Stuttle, A.W.J.; Lavender, J.P.; Danpure, H.J.; Osman, S.

    1988-01-01

    The lipophilic complex, 99 Tcsup(m)-hexamethylpropyleneamine oxime (HMPAO) is an efficient leucocyte label, and labels granulocytes with more stability than mononuclear leucocytes. The recovery of 99 Tcsup(m)-HMPAO granulocytes was similar to 111 In-labelled granulocytes isolated and labelled in plasma using tropolone. The Tsub(1/2) of 99 Tcsup(m)-HMPAO labelled granulocytes in blood was less than that of 111 In-labelled granulocytes. The initial biodistribution of 99 Tcsup(m)-labelled leucocytes was similar to 111 In-labelled granulocytes, with a rapid initial lung transit, prominent splenic activity, bone marrow activity and minimal hepatic activity, although, unlike 111 In, 99 Tcsup(m) activity was also seen in urine, occasionally in the gallbladder, and, from about 4 h, consistently in the colon. Bone marrow activity was particularly prominent with 99 Tcsup(m). About 6% of 99 Tcsup(m) was excreted in the faeces up to 48 h after injection, and about 17% in urine up to 24 h. The time-activity curves of reticuloendothelial activity up to 24 h were broadly similar for the two labelled cell preparations. Clinical information given by the two agents was similar in 27 of 30 patients who received both. We conclude that with respect to granulocyte kinetics and clinical data, 99 Tcsup(m)-HMPAO labelled leucocytes are comparable with 111 In-tropolonate labelled granulocytes. (author)

  1. Motion of 1/3<111> dislocations on Σ3 (112) twin boundaries in nanotwinned copper

    Energy Technology Data Exchange (ETDEWEB)

    Lu, N.; Du, K., E-mail: kuidu@imr.ac.cn [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Beijing National Center for Electron Microscopy, Tsinghua University, Beijing 100084 (China); Lu, L.; Ye, H. Q. [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China)

    2014-01-14

    The atomic structure of Σ3 (112) ITBs in nanotwinned Cu is investigated by using aberration-corrected high resolution transmission electron microscopy (HRTEM) and in situ HRTEM observations. The Σ3 (112) ITBs are consisted of periodically repeated three partial dislocations. The in situ HRTEM results show that 1/3[111] partial dislocation moves on the Σ3 (112) incoherent twin boundary (ITB), which was accompanied by a migration of the ITB. A dislocation reaction mechanism is proposed for the motion of 1/3[111] Frank partial dislocation, in which the 1/3[111] partial dislocation exchanges its position with twin boundary dislocations in sequence. In this way, the 1/3[111] dislocation can move on the incoherent twin boundary in metals with low stacking fault energy. Meanwhile, the ITB will migrate in its normal direction accordingly. These results provide insight into the reaction mechanism of 1/3[111] dislocations and ITBs and the associated migration of ITBs.

  2. Clinical applications of indium-111-acetylacetone-labelled blood cells

    International Nuclear Information System (INIS)

    Georgi, P.; Sinn, H.; Wellman, H.; Clorius, J.H.; Becker, W.

    1981-01-01

    A method permitting red-cell labelling with 111 In-acetylacetone was reported in 1974 for evaluating intestinal blood loss, the liver-spleen ratio and the red-cell volume. White blood cells can be tagged similarly. In white-cell labelling, simultaneous red-cell or platelet tagging is avoided. Several procedures (dextran separation and gradient centrifugations) have been combined, to develop a highly selective cell separation. In osteomyelitis it may not be as advantageous to use 67 Ga-citrate, as in inflammatory soft tissue processes. The detection of inflammatory processes with labelled leukocytes could be of great importance for the scintigraphic diagnosis of osteomyelitidies. A group of 97 patients with suspected osteomyelitis have been examined using 111 In-acetylacetone-labelled leukocytes ( 111 In-AAL) immediately following positive routine skeletal scintigraphy. Images obtained 24 h post injection usually were the most satisfactory. In the followup group of 70 patients 21 true positives, 43 true negatives, 21 false negatives and 3 false positives were observed. These findings result in a specificity of 92%, sensitivity of 50% and accuracy of 70% with 111 In-AAL for osteomyelitis. Preliminary investigations using 111 In-acetylacetone-labelled thrombocytes ( 111 In-AAT) were carried out to detect rejection of transplanted kidneys. The platelets were separated by means of additional special density gradient centrifugations but no dextran from 15-20 ml of autologous whole blood. Scans have been obtained 15 min, 2.5 h and 24 h post injection in an initial group of 10 patients. In acute rejection, a high transplant uptake has been detected, whereas patients without acute rejection showed no or only a minimum activity accumulation. Patients with chronic rejection have intermediate uptakes

  3. Dynamic hyperfine interactions in {sup 111}In({sup 111}Cd)-doped ZnO semiconductor: PAC results supported by ab initio calculations

    Energy Technology Data Exchange (ETDEWEB)

    Munoz, Emiliano L., E-mail: munoz@fisica.unlp.edu.ar [Departamento de Fisica and Instituto de Fisica La Plata (IFLP, CONICET La Plata), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, CC 67, 1900 La Plata (Argentina); Mercurio, Marcio E.; Cordeiro, Moacir R.; Pereira, Luciano F.D.; Carbonari, Artur W. [Instituto de Pesquisas Energeticas y Nucleares-IPEN-CNEN/SP, Sao Paulo (Brazil); Renteria, Mario [Departamento de Fisica and Instituto de Fisica La Plata (IFLP, CONICET La Plata), Facultad de Ciencias Exactas, Universidad Nacional de La Plata, CC 67, 1900 La Plata (Argentina)

    2012-08-15

    In this work, we present results of Time-Differential {gamma}-{gamma} Perturbed-Angular-Correlations (PAC) experiments performed in {sup 111}Cd-doped ZnO semiconductor. The PAC technique has been applied in order to characterize the electric-field-gradient (EFG) tensor at ({sup 111}In (EC){yields}) {sup 111}Cd nuclei located, as was later demonstrated, at defect-free cation sites of the ZnO host structure. The PAC experiments were performed in the temperature range of 77-1075 K. At first glance, the unexpected presence of low-intensity dynamic hyperfine interactions was observed, which were analyzed with a perturbation factor based on the Baeverstam and Othaz model. The experimental EFG results were compared with ab initio calculations performed with the Full-Potential Augmented Plane Wave plus local orbital (FP-APW+lo) method, in the framework of the Density Functional Theory (DFT), using the Wien2K code. The presence of the dynamic hyperfine interactions has been analyzed enlightened by the FP-APW+lo calculations of the EFG performed as a function of the charge state of the cell. We could correlate the large strength of the dynamic hyperfine interaction with the strong variation of the EFG due to changes in the electronic charge distribution in the Cd vicinity during the time-window of the PAC measurement. It was also revealed that the Cd impurity decays to a final stable neutral charge state (Cd{sup 2+}) fast enough (in few ns) to produce the nearly undamped observed PAC spectra.

  4. Imaging the inflammatory response to acute myocardial infarction in man using indium-111-labeled autologous platelets

    International Nuclear Information System (INIS)

    Davies, R.A.; Thakur, M.L.; Berger, H.J.; Wackers, F.J.T.; Gottschalk, A.; Zaret, B.L.

    1981-01-01

    The feasibility of imaging the inflammatory response to acute transmural myocardial infarction in man using indium-111 ( 111 In)-labeled autologous leukocytes was assessed in 36 patients. Indium-111 leukocytes were injected i.v. 18 to 112 hs after the onset of chest pain. Cardiac imaging was performed 24 hs later with a mobile gamma camera. Twenty-one patients had positive images and 15 had negative images. The percent of positive images increased as the interval between infarction and 111 In-leukocyte injection shortened; all patients injected within 24 hs of infarction had positive images. Patients with positive images were injected with 111 In leukocytes earlier after infarction and were younger than those with negative images. Several other parameters that could possibly have affected the imaging results were examined and were not significantly different in patients with positive and negative images. These included peak serum creatine kinase, location of infarction, incidence of pericarditis, use of antiinflammatory drugs or membrane-active antiarrhythmic drugs, peripheral leukocyte count, and cell labeling efficiency. The function of the labeled cells was similar in patients with positive and negative images. Six patients with acute infarction serving as controls and given free 111 In-oxine and six patients with stable coronary artery disease given 111 In-leukocytes all had negative cardiac images

  5. Interfacial Electrochemical Electron Transfer Processes in Bacterial Biofilm Environments on Au(111)

    DEFF Research Database (Denmark)

    Hu, Yifan; Zhang, Jingdong; Ulstrup, Jens

    2010-01-01

    We have studied Streptococcus mutans (S. mutans) biolilm growth and growth inhibition on Au(111)-surfaces using atomic force microscopy (AFM) and interfacial electrochemistry of a number of redox probe molecules. AFM of the biofilm growth and growth inhibition on both mica and Au(111)-surfaces wa...

  6. Internal radiotherapy and dosimetric study for 111In/177Lu-pegylated liposomes conjugates in tumor-bearing mice

    International Nuclear Information System (INIS)

    Wang, H.-E.; Yu, H.-M.; Lu, Y.-C.; Heish, N.-N.; Tseng, Yun-Long; Huang, K.-L.; Chuang, K.-T.; Chen, Chin-Hsiung; Hwang, J.-J.; Lin, W.-J.; Wang, Shyh-Jen; Ting, G.; Whang-Peng, Jacqueline; Deng, W.-P.

    2006-01-01

    In vivo characterization and dosimetric analysis has been performed to evaluate the potential of pegylated liposomes as carriers of radionuclides in tumor internal radiotherapy. Methods: The DTPA/PEG-liposomes were synthesized with a medium size of 110 nm, conjugated with 111 In/ 177 Lu-(oxine) 3 to afford 111 In/ 177 Lu-liposome. The stability of 111 In/ 177 Lu-liposome in serum was investigated. The biodistribution, scintigraphic imaging and pharmacokinetics of 111 In/ 177 Lu-liposomes after intravenous(i.v.) injection into C-26 tumor-bearing BALB/cByJ mice were studied. Radiation dose was estimated by MIRD-III program. Results: The incorporation efficiency of 111 In/ 177 Lu into liposomes was 95%. After incubation at 37 o C for 72 h in serum, more than 83% of radioactivity was still retained in the intact 111 In/ 177 Lu-liposomes. The biodistribution of 111 In-liposomes showed that the radioactivity in the blood decreased from 23.14±8.16%ID/g at 1 h to 0.02±0.00%ID/g at 72 h post-injection (p.i.), while reaching its maximum accumulation in tumors at 48 h p.i., with half-life in blood of 10.2 h. The results were supported by that of 177 Lu-liposomes. Scintigraphic imaging with 111 In-liposomes showed unambiguous tumor images at 48 h p.i. Dose estimation showed that the absorbed dose in tumor from 177 Lu-liposomes was 5.74x10 -5 Gy/MBq. Conclusions: This study provides an in vivo characterization and dosimetric evaluation for the use of liposome systems as carriers in targeted radionuclide therapy. The results suggest that adequate tumor targeting as well as dose delivered to tumors could be achieved by the use of radionuclide targeted liposomes

  7. 10 CFR 71.111 - Instructions, procedures, and drawings.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Instructions, procedures, and drawings. 71.111 Section 71... MATERIAL Quality Assurance § 71.111 Instructions, procedures, and drawings. The licensee, certificate..., procedures, or drawings of a type appropriate to the circumstances and shall require that these instructions...

  8. Vibrational dynamics and band structure of methyl-terminated Ge(111)

    Energy Technology Data Exchange (ETDEWEB)

    Hund, Zachary M.; Nihill, Kevin J.; Sibener, S. J., E-mail: s-sibener@uchicago.edu [The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57" t" h Street, Chicago, Illinois 60637 (United States); Campi, Davide; Bernasconi, M. [Dipartimento di Scienza dei Materiali, Universita di Milano-Bicocca, Via Cozzi 53, 20125 Milano (Italy); Wong, Keith T.; Lewis, Nathan S. [Division of Chemistry and Chemical Engineering, Beckman Institute and Kavli Nanoscience Institute, California Institute of Technology, 210 Noyes Laboratory, 127-72, Pasadena, California 91125 (United States); Benedek, G. [Dipartimento di Scienza dei Materiali, Universita di Milano-Bicocca, Via Cozzi 53, 20125 Milano (Italy); Donostia International Physics Center (DIPC), Universidad del País Vasco (EHU), 20018 Donostia/San Sebastian (Spain)

    2015-09-28

    A combined synthesis, experiment, and theory approach, using elastic and inelastic helium atom scattering along with ab initio density functional perturbation theory, has been used to investigate the vibrational dynamics and band structure of a recently synthesized organic-functionalized semiconductor interface. Specifically, the thermal properties and lattice dynamics of the underlying Ge(111) semiconductor crystal in the presence of a commensurate (1 × 1) methyl adlayer were defined for atomically flat methylated Ge(111) surfaces. The mean-square atomic displacements were evaluated by analysis of the thermal attenuation of the elastic He diffraction intensities using the Debye-Waller model, revealing an interface with hybrid characteristics. The methyl adlayer vibrational modes are coupled with the Ge(111) substrate, resulting in significantly softer in-plane motion relative to rigid motion in the surface normal. Inelastic helium time-of-flight measurements revealed the excitations of the Rayleigh wave across the surface Brillouin zone, and such measurements were in agreement with the dispersion curves that were produced using density functional perturbation theory. The dispersion relations for H-Ge(111) indicated that a deviation in energy and lineshape for the Rayleigh wave was present along the nearest-neighbor direction. The effects of mass loading, as determined by calculations for CD{sub 3}-Ge(111), as well as by force constants, were less significant than the hybridization between the Rayleigh wave and methyl adlayer librations. The presence of mutually similar hybridization effects for CH{sub 3}-Ge(111) and CH{sub 3}-Si(111) surfaces extends the understanding of the relationship between the vibrational dynamics and the band structure of various semiconductor surfaces that have been functionalized with organic overlayers.

  9. Vibrational dynamics and band structure of methyl-terminated Ge(111)

    International Nuclear Information System (INIS)

    th Street, Chicago, Illinois 60637 (United States))" data-affiliation=" (The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57th Street, Chicago, Illinois 60637 (United States))" >Hund, Zachary M.; th Street, Chicago, Illinois 60637 (United States))" data-affiliation=" (The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57th Street, Chicago, Illinois 60637 (United States))" >Nihill, Kevin J.; th Street, Chicago, Illinois 60637 (United States))" data-affiliation=" (The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57th Street, Chicago, Illinois 60637 (United States))" >Sibener, S. J.; Campi, Davide; Bernasconi, M.; Wong, Keith T.; Lewis, Nathan S.; Benedek, G.

    2015-01-01

    A combined synthesis, experiment, and theory approach, using elastic and inelastic helium atom scattering along with ab initio density functional perturbation theory, has been used to investigate the vibrational dynamics and band structure of a recently synthesized organic-functionalized semiconductor interface. Specifically, the thermal properties and lattice dynamics of the underlying Ge(111) semiconductor crystal in the presence of a commensurate (1 × 1) methyl adlayer were defined for atomically flat methylated Ge(111) surfaces. The mean-square atomic displacements were evaluated by analysis of the thermal attenuation of the elastic He diffraction intensities using the Debye-Waller model, revealing an interface with hybrid characteristics. The methyl adlayer vibrational modes are coupled with the Ge(111) substrate, resulting in significantly softer in-plane motion relative to rigid motion in the surface normal. Inelastic helium time-of-flight measurements revealed the excitations of the Rayleigh wave across the surface Brillouin zone, and such measurements were in agreement with the dispersion curves that were produced using density functional perturbation theory. The dispersion relations for H-Ge(111) indicated that a deviation in energy and lineshape for the Rayleigh wave was present along the nearest-neighbor direction. The effects of mass loading, as determined by calculations for CD 3 -Ge(111), as well as by force constants, were less significant than the hybridization between the Rayleigh wave and methyl adlayer librations. The presence of mutually similar hybridization effects for CH 3 -Ge(111) and CH 3 -Si(111) surfaces extends the understanding of the relationship between the vibrational dynamics and the band structure of various semiconductor surfaces that have been functionalized with organic overlayers

  10. Theoretical analysis of hydrogen chemisorption on Pd(111), Re(0001) and PdML/Re(0001), ReML/Pd(111) pseudomorphic overlayers

    DEFF Research Database (Denmark)

    Pallassana, Venkataraman; Neurock, Matthew; Hansen, Lars Bruno

    1999-01-01

    not appear to provide an independent parameter for assessing surface reactivity. The weak chemisorption of hydrogen on the Pd-ML/Re(0001) surface relates to substantial lowering of the d-band center of Pd, when it is pseudomorphically deposited as a monolayer on a Re substrate. [S0163-1829(99)00331-2].......Gradient-corrected density-functional theory (DFT-GGA) periodic slab calculations have been used to analyze the binding of atomic hydrogen on monometallic Pd(111), Re(0001), and bimetallic Pd-mL/Re(0001) [pseudomorphic monolayer of Pd(111) on Re(0001)] and Re-ML/Pd(111) surfaces. The computed...

  11. Experimental study of K-electron capture probability in the decay of {sup 111}In

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, N.R.; Kalyani, V.D.M.L.; Maldhusudhana Rao, P.V.; Vara Prasad, N.V.; Chandrasekhar Rao, M.V.S.; Satyanarayana, G.; Sastry, D.L. [Visakhapatnam, Andhra Univ. (India). Swami Jnanananda Lab. for Nuclear Research; Chintalapudi, S.N. [Calcutt, Inter-Univ. Consortium for DAEW Facilities (India)

    1998-03-01

    The K-electron capture probability in the decay of {sup 111}In to the 416.64 keV level of the daughter nucleus {sup 111}Cd was measured to be 0.853 {+-}0.037 in agreement with the theoretical value 0.865. The experimental value is seen to be consistent with the mass prediction of the relationship due to Wapstra and Bos.

  12. 21 CFR 111.12 - What personnel qualification requirements apply?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What personnel qualification requirements apply? 111.12 Section 111.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING...

  13. 48 CFR 870.111-5 - Frozen processed food products.

    Science.gov (United States)

    2010-10-01

    ... products. (3) Frozen bakery products. (b) All procured frozen processed food products that contain meat... frozen bakery products that ship products in interstate commerce are required to comply with the Federal... products. 870.111-5 Section 870.111-5 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS...

  14. 46 CFR 111.10-4 - Power requirements, generating sources.

    Science.gov (United States)

    2010-10-01

    ... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Supply § 111.10-4 Power requirements, generating sources. (a) The aggregate capacity of the electric ship's service generating sources required in § 111.10-3 must... or sources must be sufficient to supply those services necessary to provide normal operational...

  15. Clinical feasibility of two-step streptavidin/111In-biotin scintigraphy in patients with suspected vertebral osteomyelitis

    International Nuclear Information System (INIS)

    Lazzeri, Elena; Erba, Paola A.; Volterrani, Duccio; Bottoni, Antonio; Mariani, Giuliano; Pauwels, Ernest K.J.; Manca, Mario; Bodei, Lisa; Trippi, Donatella; Cristofani, Renza; Consoli, Vincenzo; Palestro, Christopher J.

    2004-01-01

    Streptavidin accumulates at sites of inflammation and infection as a result of increased capillary permeability. In addition to being utilised by bacteria for their own growth, biotin forms a stable, high-affinity non-covalent complex with avidin. The objective of this investigation was to determine the diagnostic performance of two-step streptavidin/ 111 In-biotin imaging for evaluating patients with suspected vertebral osteomyelitis. We evaluated 55 consecutive patients with suspected vertebral osteomyelitis (34 women and 21 men aged 27-86 years), within 2 weeks after the onset of clinical symptoms. Thirty-two of the patients underwent magnetic resonance imaging (MRI) and 24, computed tomography (CT). DTPA-conjugated biotin was radiolabelled by incubating 500 μg of DTPA-biotin with 111 MBq of 111 In-chloride. Two-step scintigraphy was performed by first infusing 3 mg streptavidin intravenously, followed 4 h later by 111 In-biotin. Imaging was begun 60 min later. Streptavidin/ 111 In-biotin scintigraphy was positive in 32/34 patients with spinal infection (94.12% sensitivity). The study was negative in 19/21 patients without infection (95.24% specificity). The corresponding results for MRI and CT were 54.17% and 35.29% (sensitivity), and 75% and 57.14% (specificity), respectively. All statistical parameters of diagnostic performance (Youden's J index, kappa measure of agreement with correct classification, accuracy, sensitivity, specificity, positive likelihood and negative likelihood) were clearly better for streptavidin/ 111 In-biotin scintigraphy than for either MRI or CT. Streptavidin/ 111 In-biotin scintigraphy is highly sensitive and specific for detecting vertebral osteomyelitis in the first 2 weeks after the onset of clinical symptoms, and is potentially very useful for guiding clinical decisions on instituting appropriate therapy. (orig.)

  16. The Bombyx mori nucleopolyhedrovirus Bm111 affects virulence but not virus replication.

    Science.gov (United States)

    Han, Yingying; Xia, Hengchuan; Tang, Qi; Lü, Peng; Ma, Shangshang; Yang, Yanhua; Shao, Dandan; Ma, Quanbing; Chen, Keping

    2014-07-01

    The Bm111 of Bombyx mori nucleopolyhedrovirus (BmNPV) encodes a small polypeptide (70 amino acids) of which the function remains unknown. To characterize its function, multiple sequence alignments were performed, and the predicted protein was found to share amazingly high (98 %) sequence identity with the Bombyx mandarina nucleopolyhedrovirus ORF110 (Boma110) but negligible with proteins of other insect viruses, indicating the close relationship between these two NPVs with silkworm larvae. The transcription of Bm111 was detected as early as 3 hpi in BmNPV-infected BmN cells, suggesting it is an early gene. To investigate the role of Bm111 in baculovirus life cycle, a Bm111-knockout virus was constructed by bacmid recombination in Escherichia coli. The results showed that knockout of the Bm111 did not affect the replication of virus DNA, but significantly extended the death time of infected silkworm larvae compared to the wild-type or rescued viruses. We also successfully expressed the recombinant protein Bm111 in E. coli to provide sufficient material for subsequent studies. Taken together, our data indicate that Bm111 only affects the virulence of BmNPV, but not its replication.

  17. Leucocytes labelled with In-111-oxine in acute inflammatory processes

    International Nuclear Information System (INIS)

    Herranz, R.; Lomena, F.; Fernandez, R.M.; Del Rio, L.; Piera, C.; Vida, F.; Setoain, J.

    1982-01-01

    We used autologous leucocytes labelled with In-111-Oxine to diagnose inflammatory processes, located or scattered, in 60 patients. In 46 there was suspected located infection focus. Gammagraphy was abnormal in 38 cases (83%), 28 abdominally located (87%), 5 thorax located (71%) and 5 of several locations. In other 14 cases there was clinic suspicion of infection without located septic focus. In 5 of them gammagraphy was interpreted as positive but only in 3 patients it was found abdominal located abscess. The two other cases are considered as false positive ones. In the 9 remaining, with negative gammagraphy there was no clinic confirmation nor other diagnostic methods of abscess existence. In this paper we checked high sensitivity of leucocytes In-111-Oxine to diagnose and locate infectious focuses. In our casuistry there was only a false negative and two false positive ones

  18. (111)Indium-transferrin for localization and quantification of gastrointestinal protein loss

    DEFF Research Database (Denmark)

    Simonsen, Jane Angel; Braad, Poul-Erik; Veje, Annegrete

    2009-01-01

    Objective. To evaluate the indium-111 ((111)In)-transferrin method as a means of localization and quantification of gastrointestinal protein loss. Methods. Fourteen patients and 15 healthy subjects underwent an (111)In-transferrin study consisting of abdominal scintigraphy, whole-body counting...... measurement and determination of plasma activity of (111)In during the course of 5 days. Two of the patients went through a subsequent chromium-51-trichloride test with analysis of radioactivity in faeces in order to compare the results of the two methods. Results. The patients had a mean+/-SEM whole-body...... loss of (111)In of 10.9+/-2.9% for 96 h, while the healthy controls lost 1.8+/-1.3% (p=0.0045). The decay in plasma activity followed biexponential kinetics. The characteristic plasma transit time was 5.0+/-1.0 h in patients and 12.1+/-1.5 h in controls (p=0.0007). Scintigraphically, patients had...

  19. Investigation of (111 wafers and comparison with (100 substrates

    Directory of Open Access Journals (Sweden)

    A Bahari

    2012-06-01

    Full Text Available  In the last decade, Si(100 has been used as a suitable substrate in field effect transistors. Some issues such as leakage current and tunneling current through the ultrathin films have been increased with shrinking the electronic devices – particularly, field effect transistors – to nanoscale, which is threatening more use of Si(100. We have thus demonstrated a series of experiments to grow ultrathin films on both Si(100 and Si(111 substrates and studied their nanostructural properties to see the possibility of replacing Si(100 with Si(111. The obtained results indicate that Si(111 substrate with silicon nitride film on top is desirable.

  20. 26 CFR 521.111 - Pensions and life annuities.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Pensions and life annuities. 521.111 Section... Denmark and of Danish Corporations § 521.111 Pensions and life annuities. Under the provisions of Article X(2) of the convention, private pensions and life annuities derived from sources within the United...

  1. Studies on the hepatic uptake of In-111 labeled monoclonal antibodies and the method to reduce the hepatic uptake

    International Nuclear Information System (INIS)

    Kinuya, Seigo

    1990-01-01

    Prolonged retention of In-111 labeled monoclonal antibody (In-111 MoAb) in the liver poses problems in radioimmunoscintigraphy. Therefore, subcellular kinetics of In-111 MoAb was investigated. In a study with In-111 225.28S in normal SD rats, the supernatant was found to be a predominant fraction of In-111 radioactivity (61% at 3 hr), with the activity decreasing with time to 21% at 72 hr; however, activity of the mitochondrial fraction was found to increase from 11% to 44%. High performance liquid chromatography for the supernatant revealed that In-111 activity at the earlier time was mainly eluted with the intact IgG peak, and that the major peak activity was thereafter reduced with associated activity peaks found in smaller moistly fractions. Such a sequential distribution change of In-111 225.28S was not found when labeled with I-125. A study with In-111 ZCE025 in mice bearing human colon cancer revealed that activity of the supernatant fraction decreased with time, but the lysosomal activity increased from 14% to 29%, as found in the experiment using normal rats. In tumors, the subcellular distribution of In-111 radioactivity almost remained unchanged throughout the study. The lysosomal fraction was not a predominant fraction of In-111 radioactivity in tumors. When 4 mg of ferric ion (Fe) was administered 48 hr before the injection of In-111 ZCE025, liver uptake of In-111 decreased as compared with the non-Fe group, but tumor uptake was unchanged. Intrahepatic lysosomal radioactivity was smaller in the Fe group than the non-Fe group. These results indicated the involvement of lysosomes in hepatic retention of In-111 MoAb. Once taken up by the liver, the MoAb was metabolized in the supernatant and In-111 ion was transchelated from DTPA onto the lysosomal substances resulting in prolonged retention in the liver. The lysosome in the liver could be saturated by Fe, resulting in a decrease of hepatic uptake without a decrease of tumor uptake. (N.K.) 53 refs

  2. Current status of indium-111 labeled bleomycin for tumor detection

    International Nuclear Information System (INIS)

    Taylor, R.D.; Blahd, W.H.

    1975-01-01

    The advantages and disadvantages of 111 In-labeled bleomycin for tumor detection are briefly mentioned. Indium-111 labeled bleomycin does localize in human tumors. However, its role in tumor detection and staging as compared with 67 Ga is still somewhat controversial

  3. Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients

    International Nuclear Information System (INIS)

    Lazzeri, E.; Molea, N.; Bodei, L.; Bianchi, R.; Manca, M.; Marchetti, S.; Consoli, V.; Chinol, M.; Paganelli, G.; Mariani, G.

    1999-01-01

    We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by 111 In-biotin; imaging was acquired 30 min and 16-18 h after administration of 111 In-biotin. Technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/ 111 In-biotin scan was 97.7% (versus 88.9% for 99m Tc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/ 111 In-biotin scintigraphy was similar to that of 99m Tc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/ 111 In-biotin approach clearly performed better than 99m Tc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for 99m Tc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/ 111 In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/ 111 In-biotin scintigraphy were found versus 99m Tc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. (orig.)

  4. Quantum tunneling in real space: Tautomerization of single porphycene molecules on the (111) surface of Cu, Ag, and Au

    Science.gov (United States)

    Kumagai, Takashi; Ladenthin, Janina N.; Litman, Yair; Rossi, Mariana; Grill, Leonhard; Gawinkowski, Sylwester; Waluk, Jacek; Persson, Mats

    2018-03-01

    Tautomerization in single porphycene molecules is investigated on Cu(111), Ag(111), and Au(111) surfaces by a combination of low-temperature scanning tunneling microscopy (STM) experiments and density functional theory (DFT) calculations. It is revealed that the trans configuration is the thermodynamically stable form of porphycene on Cu(111) and Ag(111), whereas the cis configuration occurs as a meta-stable form. The trans → cis or cis → trans conversion on Cu(111) can be induced in an unidirectional fashion by injecting tunneling electrons from the STM tip or heating the surface, respectively. We find that the cis ↔ cis tautomerization on Cu(111) occurs spontaneously via tunneling, verified by the negligible temperature dependence of the tautomerization rate below ˜23 K. Van der Waals corrected DFT calculations are used to characterize the adsorption structures of porphycene and to map the potential energy surface of the tautomerization on Cu(111). The calculated barriers are too high to be thermally overcome at cryogenic temperatures used in the experiment and zero-point energy corrections do not change this picture, leaving tunneling as the most likely mechanism. On Ag(111), the reversible trans ↔ cis conversion occurs spontaneously at 5 K and the cis ↔ cis tautomerization rate is much higher than on Cu(111), indicating a significantly smaller tautomerization barrier on Ag(111) due to the weaker interaction between porphycene and the surface compared to Cu(111). Additionally, the STM experiments and DFT calculations reveal that tautomerization on Cu(111) and Ag(111) occurs with migration of porphycene along the surface; thus, the translational motion couples with the tautomerization coordinate. On the other hand, the trans and cis configurations are not discernible in the STM image and no tautomerization is observed for porphycene on Au(111). The weak interaction of porphycene with Au(111) is closest to the gas-phase limit and therefore the absence

  5. Leukemic cell labeling with indium-111-oxine

    International Nuclear Information System (INIS)

    Uchida, T.; Takagi, Y.; Matsuda, S.; Yui, T.; Ishibashi, T.; Kimura, H.; Kariyone, S.

    1984-01-01

    Leukemic cells were labeled with In-111-oxine in patients with acute leukemia. In vitro labeling studies revealed that labeling efficiency reached maximum 80.8 +- 3.6% (mean +- 1SD) by 2 times washes after 20 minutes incubation time. Cell viability was assessed by trypan blue exclusion test and in vitro culture of leukemic cells, which showed no cellular damage during labeling procedure. Elution of In-111 from the labeled cells was 10.0 +- 1.2% at 12 hours after labeling. For in vivo leukemic cell kinetic studies, more than 10/sup 8/ leukemic cells separated from Ficoll-Hypacque sedimentation were labeled by 30 minutes of In-111-oxine incubation and two times washes at 37 0 C. In vivo studies were performed in 7 patients with acute myeloblastic, lymphoblastic leukemia and blastic crisis of chronic myelocytic leukemia. Labeled leukemic cells disappeared in single exponential fashion with half life of 9.6 to 31.8 hours. Total leukemic cell pool in peripheral circulation was calculated, which correlated well with peripheral leukemic cell counts (r=0.99). No relationship was observed between total leukemic cell pool and leukemic cell turnover rate. Migration patterns of labeled leukemic cells showed that pulmonary uptake was evident within 15 minutes after the infusion and returned to base-line. Splenic and hepatic uptake showed gradual increase up to 24 hours. Bone marrow accumulation was shown only in 2 cases. Presently, there are no suitable radionuclides for leukemic cell labeling. In-111-oxine labeled leukemic cells would overcome this difficulty

  6. Kinetics and sites of destruction of 111In-oxine-labeled platelets in idiopathic thrombocytopenic purpura: a quantitative study

    International Nuclear Information System (INIS)

    Heyns, A.D.; Loetter, M.G.; Badenhorst, P.N.; de Kock, F.; Pieters, H.; Herbst, C.; van Reenen, O.R.; Kotze, H.; Minnaar, P.C.

    1982-01-01

    Kinetics and quantification of the sites of destruction of 111 In-oxine-labeled autologous platelets were investigated in eight patients with idiopathic thrombocytopenic purpura. The mean platelet count was 17 +/- 9 X 10(9)/liter; platelets were separated by differential centrifugation and labeled with 5.6 +/- 2.5 MBq 111 In. Whole body and organ 111 In-platelet distribution was quantitated with a scintillation camera and a computer-assisted imaging system acquisition matrix. Areas of interest were selected with the computer and organ 111 In-radioactivity expressed as a percentage of whole body activity. Mean platelet survival was 49.5 +/- 29.6 hr and the survival curves were exponential. Equilibrium percentage organ 111 In-radioactivity was (normal values in parentheses): spleen 33.7 +/- 8.8 (31.1 +/- 10.2); liver 16.1 +/- 9.5 (13.1 +/- 1.3); thorax 22.8 +/- 3.7 (28.2 +/- 5.6). Percentage organ 111 In-activity at the time when labeled platelets had disappeared from the circulation was: spleen 44.5 +/- 16.4 (40 +/- 16); liver 16.0 +/- 11.5 (32.4 +/- 7.2); thorax 19.7 +/- 6.0 (17.7 +/- 10.3). Thorax activity corresponds to bone marrow radioactivity. Three patterns of platelet sequestration were evident. Three patients had mainly splenic sequestration, two mainly hepatic sequestration, and three diffuse reticuloendothelial system sequestration with a major component of platelets destroyed in the bone marrow. Splenectomy was performed in two patients. The pattern of 111 In-platelet sequestration was not predictive of response of glucocorticoid therapy or indicative of the necessity for splenectomy. Quantitative 111 In-labeled autologous platelet kinetic studies provide a new tool for the investigation of platelet disorders.U

  7. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J.

    1989-01-01

    Although few reports address the use of three-phase bone scanning (TPBS) and 111 In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses

  8. Modelling study on production cross sections of {sup 111}In radioisotopes used in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Kara, Ayhan; Korkut, Turgay [Sinop Univ. (Turkey). Faculty of Engineering; Yigit, Mustafa [Aksaray Univ. (Turkey). Faculty of Science and Arts; Tel, Eyyup [Osmaniye Korkut Ata Univ. (Turkey). Faculty of Science and Arts

    2015-07-15

    Radiopharmaceuticals are radioactive drugs used for diagnosis or treatment in a tracer quantity with no pharmacological action. The production of radiopharmaceuticals is carried out in the special research centers generally using by the cyclotron systems. Indium-111 is one of the most useful radioisotopes used in nuclear medicine. In this paper, we calculated the production cross sections of {sup 111}In radioisotope via {sup 111-114}Cd(p,xn) nuclear reactions up to 60 MeV energy. In the model calculations, ALICE/ASH, TALYS 1.6 and EMPIRE 3.2 Malta nuclear reaction code systems were used. The model calculation results were compared to the experimental literature data and TENDL-2014 (TALYS-based) data.

  9. Strong Quantum Size Effects in Pb(111) Thin Films Mediated by Anomalous Friedel Oscillations

    Science.gov (United States)

    Jia, Yu; Wu, Biao; Li, Chong; Einstein, T. L.; Weitering, H. H.; Zhang, Zhenyu

    2010-08-01

    Using first-principles calculations within density functional theory, we study Friedel oscillations (FOs) in the electron density at different metal surfaces and their influence on the lattice relaxation and stability of ultrathin metal films. We show that the FOs at the Pb(111) surface decay as 1/x with the distance x from the surface, different from the conventional 1/x2 power law at other metal surfaces. The underlying physical reason for this striking difference is tied to the strong nesting of the two different Fermi sheets along the Pb(111) direction. The interference of the strong FOs emanating from the two surfaces of a Pb(111) film, in turn, not only results in superoscillatory interlayer relaxations around the center of the film, but also determines its stability in the quantum regime. As a simple and generic picture, the present findings also explain why quantum size effects are exceptionally robust in Pb(111) films.

  10. Slow positron studies on single crystals of Ag(100), Ag(111) and Cu(111)

    International Nuclear Information System (INIS)

    Lynn, K.G.

    1979-01-01

    Monoenergetic positrons were employed to examine positronium formation as a function of sample temperature (300 to 1200 K) and incident energy (0 to 5 keV) on Ag(100), Ag(111) and Cu(111) surfaces with submonolayer contamination. In these metals at the higher temperatures, positronium formation becomes the dominant process. A one-dimensional diffusion model is fit to the data as a function of incident energy. Th positronium fraction is found to be an activated process and is identified as detrapping from a surface state and an estimate of the depth of this trap is extracted. The diffusion length is found to be temperature independent before the onset of vacancy trapping. At the higher temperatures vacancy trapping is observed by the decrease in the positron diffusion length at the higher incident voltages. A vacancy formation energy is extracted from the data and is generally lower than the accepted bulk values. 18 references

  11. Osteomyelitis and infarction in sickle cell hemoglobinopathies: differentiation by combined technetium and gallium scintigraphy

    International Nuclear Information System (INIS)

    Amundsen, T.R.; Siegel, M.J.; Siegel, B.A.

    1984-01-01

    Clinical records and scintigrams were reviewed of 18 patients with sickle cell hemoglobinophaties who had undergone combined technetium and gallium scintigraphy during 22 separate episodes of suspected osseous infection. The combined scintigrams were correctly interpreted as indicating osteomyelitis in four studies. Of 18 studies in patients with infarction, the combined scintigrams were correctly interpreted in 16 and showed either no local accumulation of Ga-67 or less accumulation than that of Tc-99m MDP at symptomatic sites. In the other two studies, the scintigrams were falsely interpreted as indicating osteomyelitis and showed congruent, increased accumulation of both Tc-99, MDP and Ga-67. This pattern must be considered indeterminate. Overall, the results indicate that the combination of technetium and gallium scintigraphy is an effective means to distinguish osteomyelitis from infarction in patients with sickle cell hemoglobinopathies

  12. Molecular distortion and charge transfer effects in ZnPc/Cu(111)

    KAUST Repository

    Amin, B.; Nazir, S.; Schwingenschlö gl, Udo

    2013-01-01

    The adsorption geometry and electronic properties of a zinc-phthalocyanine molecule on a Cu(111) substrate are studied by density functional theory. In agreement with experiment, we find remarkable distortions of the molecule, mainly as the central Zn atom tends towards the substrate to minimize the Zn-Cu distance. As a consequence, the Zn-N chemical bonding and energy levels of the molecule are significantly modified. However, charge transfer induces metallic states on the molecule and therefore is more important for the ZnPc/Cu(111) system than the structural distortions.

  13. Molecular distortion and charge transfer effects in ZnPc/Cu(111)

    KAUST Repository

    Amin, B.

    2013-04-23

    The adsorption geometry and electronic properties of a zinc-phthalocyanine molecule on a Cu(111) substrate are studied by density functional theory. In agreement with experiment, we find remarkable distortions of the molecule, mainly as the central Zn atom tends towards the substrate to minimize the Zn-Cu distance. As a consequence, the Zn-N chemical bonding and energy levels of the molecule are significantly modified. However, charge transfer induces metallic states on the molecule and therefore is more important for the ZnPc/Cu(111) system than the structural distortions.

  14. Improvement of the WBC calibration of the Internal Dosimetry Laboratory of the CDTN/CNEN using MCNPX code

    Energy Technology Data Exchange (ETDEWEB)

    Guerra P, F.; Heeren de O, A. [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Programa de Pos Graduacao em Ciencias e Tecnicas Nucleares, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Melo, B. M.; Lacerda, M. A. S.; Da Silva, T. A.; Ferreira F, T. C., E-mail: tcff01@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear, Programa de Pos Graduacao / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    The Plan of Radiological Protection licensed by the National Nuclear Energy Commission - CNEN in Brazil includes the risks of assessment of internal and external exposure by implementing a program of individual monitoring which is responsible of controlling exposures and ensuring the maintenance of radiation safety. The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology - LID/CDTN is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs). These are, the IOEs involved in handling {sup 18}F produced by the Unit for Research and Production of Radiopharmaceuticals sources; as well a monitoring of the entire body of workers from the Research Reactor TRIGA IPR-R1/CDTN or whenever there is any risk of accidental incorporation. The determination of photon emitting radionuclides from the human body requires calibration techniques of the counting geometries, in order to obtain a curve of efficiency. The calibration process normally makes use of physical phantoms containing certified activities of the radionuclides of interest. The objective of this project is the calibration of the WBC facility of the LID/CDTN using the BOMAB physical phantom and Monte Carlo simulations. Three steps were needed to complete the calibration process. First, the BOMAB was filled with a KCl solution and several measurements of the gamma ray energy (1.46 MeV) emitted by {sup 40}K were done. Second, simulations using MCNPX code were performed to calculate the counting efficiency (Ce) for the BOMAB model phantom and compared with the measurements Ce results. Third and last step, the modeled BOMAB phantom was used to calculate the Ce covering the energy range of interest. The results showed a good agreement and are within the expected ratio between the measured and simulated results. (Author)

  15. Improvement of the WBC calibration of the Internal Dosimetry Laboratory of the CDTN/CNEN using MCNPX code

    International Nuclear Information System (INIS)

    Guerra P, F.; Heeren de O, A.; Melo, B. M.; Lacerda, M. A. S.; Da Silva, T. A.; Ferreira F, T. C.

    2015-10-01

    The Plan of Radiological Protection licensed by the National Nuclear Energy Commission - CNEN in Brazil includes the risks of assessment of internal and external exposure by implementing a program of individual monitoring which is responsible of controlling exposures and ensuring the maintenance of radiation safety. The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology - LID/CDTN is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs). These are, the IOEs involved in handling 18 F produced by the Unit for Research and Production of Radiopharmaceuticals sources; as well a monitoring of the entire body of workers from the Research Reactor TRIGA IPR-R1/CDTN or whenever there is any risk of accidental incorporation. The determination of photon emitting radionuclides from the human body requires calibration techniques of the counting geometries, in order to obtain a curve of efficiency. The calibration process normally makes use of physical phantoms containing certified activities of the radionuclides of interest. The objective of this project is the calibration of the WBC facility of the LID/CDTN using the BOMAB physical phantom and Monte Carlo simulations. Three steps were needed to complete the calibration process. First, the BOMAB was filled with a KCl solution and several measurements of the gamma ray energy (1.46 MeV) emitted by 40 K were done. Second, simulations using MCNPX code were performed to calculate the counting efficiency (Ce) for the BOMAB model phantom and compared with the measurements Ce results. Third and last step, the modeled BOMAB phantom was used to calculate the Ce covering the energy range of interest. The results showed a good agreement and are within the expected ratio between the measured and simulated results. (Author)

  16. The value of indium 111 leukocyte scanning in the evaluation of painful or infected total knee arthroplasties

    International Nuclear Information System (INIS)

    Rand, J.A.; Brown, M.L.

    1990-01-01

    Evaluation of painful total knee arthroplasties (TKAs) for infection can be difficult. Indium 111 ( 111 In) leukocyte bone scanning provides a minimally invasive technique for evaluation of possible infection. Thirty-eight patients with a painful TKA who had surgical exploration after 111 In leukocyte scanning were reviewed. The scan had an accuracy of 84%, a sensitivity of 83%, and a specificity of 85%. The 111 In leukocyte scans must be interpreted in conjunction with the clinical evaluation of the patient because they are less accurate for study of TKAs than of total hip arthroplasties

  17. Evaluation of indium-111-labeled antifibrin monoclonal antibody for the diagnosis of venous thrombotic disease

    International Nuclear Information System (INIS)

    De Faucal, P.; Peltier, P.; Planchon, B.; Dupas, B.; Touze, M.D.; Baron, D.; Scaible, T.; Berger, H.J.; Chatal, J.F.

    1991-01-01

    The potential advantage of using 111 In-antifibrin ( 111 In-AF) monoclonal antibody for the diagnosis of deep venous thrombosis (DVT) was studied in 44 patients with suspected DVT (27 underwent heparin therapy before 111 In-AF injection). All patients had contrast venography (considered as the gold standard) and 111 In-AF scintigraphy within 24 hr. Two to 3 mCi of 111 In-AF were injected intravenously, and planar scintigraphy of the limbs was recorded within 10 min (17 times), 3 hr (44 times), and 18 hr (39 times). Indium-111-AF images were then interpreted without knowledge of the results of the other examinations. The DVT diagnostic accuracy of 111 In-AF was greater when interpretation was based on images recorded at different time periods after injection. Indium-111-AF sensitivity for diagnosis of DVT was 85% (29/34) and was not apparently decreased by heparin therapy. None of the 10 patients with negative contrast venography had a positive 111 In-AF scan. The results demonstrate the importance of recording serial images and the excellent accuracy of 111 In-AF for diagnosing DVT

  18. Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients

    Energy Technology Data Exchange (ETDEWEB)

    Lazzeri, E.; Molea, N.; Bodei, L.; Bianchi, R. [Regional Centre of Nuclear Medicine, University of Pisa, Pisa (Italy); Manca, M.; Marchetti, S.; Consoli, V. [Institute of Orthopedics, University of Pisa, Pisa (Italy); Chinol, M.; Paganelli, G. [Nuclear Medicine Service, European Institute of Oncology, Milan (Italy); Mariani, G. [Nuclear Medicine Service, DIMI, University of Genoa, Genoa (Italy)

    1999-06-01

    We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by {sup 111}In-biotin; imaging was acquired 30 min and 16-18 h after administration of {sup 111}In-biotin. Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/{sup 111}In-biotin scan was 97.7% (versus 88.9% for {sup 99m}Tc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/{sup 111}In-biotin scintigraphy was similar to that of {sup 99m}Tc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/{sup 111}In-biotin approach clearly performed better than {sup 99m}Tc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for {sup 99m}Tc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/{sup 111}In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/{sup 111}In-biotin scintigraphy were found versus {sup 99m}Tc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators. (orig.) With 3 figs., 2 tabs., 56 refs.

  19. Seismic strengthening of building 111 at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Eli, M.; Coats, D.; Freeland, G.; Kamath, M.

    1991-01-01

    Since being designed and constructed in the late 1960s, the Director's Building (Building 111) at Lawrence Livermore National Laboratory (LLNL) has been evaluated for 1988 seismic criteria and has been upgraded to withstand a major earthquake in the Livermore area. During and immediately after a large earthquake in the Livermore area, Building 111 occupants would be able to exit safely without loss of life. Building 111 itself would be severely damaged, but would not collapse. Highlights of the seismic upgrade design criteria and of the design, analyses, and construction that resulted are presented in this paper

  20. 111In-Pentetreotide SPECT/CT in Pulmonary Carcinoid.

    Science.gov (United States)

    Chiaravalloti, Agostino; Spanu, Angela; Danieli, Roberta; Dore, Francesca; Piras, Bastiana; Falchi, Antonio; Tavolozza, Mario; Madeddu, Giuseppe; Schillaci, Orazio

    2015-07-01

    We evaluated somatostatin receptor scintigraphy (SRS) with (111)In-pentetreotide incremental value in pulmonary carcinoid (PC) diagnosis compared to contrast enhanced Computed Tomography (ceCT). We enrolled 81 patients with ascertained PC, 39 at initial staging and 42 in follow-up; the primary tumor had already been excised in 68 cases. Single Photon emission Computed Tomography (SPECT) images were reconstructed with the iterative method and fused with non-enhanced Computed tomography (CT) images. Primary PC or metastatic lesions were ascertained in 55/81 patients and SPECT/CT was positive in 50/55 cases, while ceCT was positive in 44/55. Comparing SPECT/CT with ceCT results, we found a sensitivity of 96 vs. 87.5%, and specificity of 92% vs. 97% for the detection of primary lesion or recurrent disease. A total of 198 lesions were ascertained at SPECT/CT, while 161 at ceCT, with values of sensitivity and specificity of 85.5% and 84.6% for SRS and 75.2% and 90.5% respectively. (111)In-Pentetreotide SPECT/CT proved to be more sensitive and accurate than ceCT, thus enhancing its role in evaluating patients with PC. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  1. Radioimmunoimaging in malignant melanoma with 111In-labeled monoclonal antibody 96.5

    International Nuclear Information System (INIS)

    Murray, J.L.; Rosenblum, M.G.; Sobol, R.E.

    1985-01-01

    A radiolabeled monoclonal antibody (96.5) reactive with an Mr 97,000 antigen found on over 80% of melanoma cell lines and tissue extracts was examined for its ability to detect malignant melanoma metastases in vivo. For imaging purposes, it was conjugated with diethyltriaminepentaacetic acid and subsequently labeled with 111 In by chelation. Thirty-one patients with metastatic melanoma received single injections of monoclonal antibody 96.5 at concentrations ranging from 0.5 to 20 mg and at specific activities of 111 In ranging from 0.125 to 4 mCi/mg. Total-body scans were performed at various time intervals following administration. No serious side effects were observed. Of a total of 100 previously documented metastatic sites, 50 imaged for a specificity of 50%. The number of sites imaged increased significantly as the amount of antibody administered increased relative to the average radiation dose. Considerable background uptake of isotope was observed in blood pool and other organs with gradual acquisition of label in tumor sites by 48 to 72 h. Hence, tumor imaging of melanoma using 111 In-labeled monoclonal antibody 96.5 appeared feasible, especially at antibody doses above 2 mg

  2. First-principle study of Mg adsorption on Si(111) surfaces

    International Nuclear Information System (INIS)

    Min-Ju, Ying; Ping, Zhang; Xiao-Long, Du

    2009-01-01

    We have carried out first-principle calculations of Mg adsorption on Si(111) surfaces. Different adsorption sites and coverage effects have been considered. We found that the threefold hollow adsorption is energy-favoured in each coverage considered, while for the clean Si(111) surface of metallic feature, we found that 0.25 and 0.5 ML Mg adsorption leads to a semiconducting surface. The results for the electronic behaviour suggest a polarized covalent bonding between the Mg adatom and Si(111) surface. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  3. The effects of indium-111 decay on pBR322 DNA

    International Nuclear Information System (INIS)

    Sahu, S.K.; Adelstein, S.J.; Makrigiorgos, G.M.; Baranowska-Kortylewicz, J.

    1995-01-01

    We have compared the effectiveness in causing DNA strand breaks of 111 In bound to DNA or free in aqueous solution with that of γ rays. Supercoiled DNA from pBR322 plasmid labeled with [ 3 H]thymidine was purified and mixed with 111 InCl 3 in the absence of presence of diethylenetriaminepentaacetic dianhydride (DTPA), a metal chelator which prevents the binding of indium to DNA. The reaction mixtures were stored at 4 degrees C to accumulate radiation dose from the decay of 111 In. The DNA was then resolved by gel electrophoresis into supercoiled, nicked circular and linear forms, representing undamaged DNA, single-strand breaks (SSBs) and double-strand breaks (DSBs), respectively. The D o values of pBR322 DNA exposed to γ radiation from an external 137 Cs source and the decay of 111 In dispersed in solution (+DTPA) are 3.1 ± 0.1 and 2.8 ± 0.1 Gy, respectively. In terms of accumulated 111 In disintegrations cm -3 of plasmid DNA solution, the D o value is 15.3 (± 0.7) x 10 10 disintegrations in the absence of DTPA and 38.2 (± 1.1) x 10 10 disintegrations in its presence. Since only 14.6 ± 5% of the 111 In was bound to DNA in the absence of DTPA, an effective D o for bound 111 In of 3.4 (± 1.1) x 10 10 disintegrations is obtained. The 11-fold (range 9- to 17-fold) increased effectiveness of this Auger electron emitter when in proximity to DNA appears to be due mainly to the higher yield of SSBs. 34 refs., 4 figs., 3 tabs

  4. Detection of acute synthetic vascular graft infection with IN-111 labeled leukocyte imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Dries, D.; Lawrence, P.; Murphy, K.; Kercher, J.; Datz, F.; Christian, P.; Taylor, A.

    1985-01-01

    Synthetic vascular graft infection is characterized by late diagnosis due to indolent and nonspecific symptoms. Reported data on accuracy of In-111 labeled leukocyte imaging to identify vascular graft infection is sparse and conflicting. The purpose of this animal study was to clarify the accuracy of detection of early graft infection using a mixed population of In-111 labeled leukocytes. Twelve mongrel dogs received dacron aortic interposition grafts. Seven grafts were contaminated at surgery by topical ATCC S. aureus, 10/sup 8/ organisms per ml. Six control animals received no graft contamination Mixed population In-111 homologous leukocyte labeling was performed followed by imaging at 24 and 48 hours following intravenous injection of 250 μCi In-111 leukocytes. Scans were done on Day 2 post-surgery. Infected dogs were sacrificed following Indium imaging; control dogs were rescanned at 3 weeks postop and sacrificed thereafter. Autopsy results were correlated with scans, yielding sensitivity 71%, specificity 100%, accuracy 85% for In-111 leukocyte imaging to detect early graft infection. False positive leukocyte imaging in the early postop period was not a problem. At autopsy all 5 dogs with infected grafts and positive scans had gross pus. The 2 dogs with false negative scans showed no gross pus at autopsy; cultures were positive for S. aureus in all 7 dogs. Scans at 2 days and 3 weeks post-surgery were true negatives in all 6 control dogs. These data suggest a high level of clinical reliability of leukocyte imaging for early graft infection detection

  5. 19 CFR 111.35 - Acceptance of fees from attorneys.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Acceptance of fees from attorneys. 111.35 Section... OF THE TREASURY CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.35 Acceptance of... arrangement with an attorney) on account of any case litigated in any court of law or on account of any other...

  6. Relationship between segmental thallium-201 uptake and regional myocardial blood flow in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Nichols, A.B.; Weiss, M.B.; Sciacca, R.R.; Cannon, P.J.; Blood, D.K.

    1983-01-01

    The relationship between the spatial distribution of thallium-201 in myocardial perfusion scintigrams and the distribution of left ventricular regional myocardial blood flow was examined in 25 patients undergoing coronary arteriography. Thallium-201 myocardial scintigrams were obtained after symptom-limited exercise and after a 4 hr delay. Regional myocardial blood flow was measured by the xenon-133 clearance method in patients at rest and during rapid atrial pacing to a double product comparable with that achieved during exercise stress testing. Patterns of regional thallium-201 activity and regional myocardial blood flow, recorded in similar left anterior oblique projections, were compared for left ventricular segments supplied by the left anterior descending (LAD) and left circumflex (CIRC) arteries. In 11 patients without significant lesions of the left coronary artery (group 1), thallium-201 was homogeneously distributed in the LAD and CIRC distributions in scintigrams taken during peak exercise; these scintigrams correspond to homogeneous regional myocardial blood flow in the LAD and CIRC regions during pacing-induced stress. In 14 patients with significant lesions of the left coronary artery (group 2), ratios of regional thallium-201 activity in the LAD and CIRC distributions of exercise scintigrams correlated well (r . .84) with ratios of regional myocardial blood flow measured during rapid pacing. Background subtraction altered the relationship between relative thallium-201 uptake and regional myocardial blood flow, causing overestimation of the magnitude of flow reduction on exercise scintigrams

  7. Quantitative evaluation of endothelial cell attachment to vascular graft materials using In-111 Oxine label

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.M.; Kesler, K.A.; Stinson, J.; Mock, B.; Arnold, M.

    1985-05-01

    Human umbilical vein endothelial cells were harvested, cultured and labeled with In-111 oxine using a modification of the technique described by Sharefkin et al. Average cell labeling efficiency was 42%. Two graft materials, polytetrafluoroethylene (Gortex) and polyester elastomer (Hytrel), with and without pretreatment with human fibronectin (FN) were incubated with the labeled cells. Quantitation of In-111 activity was done 3 times: at inoculation, after incubation (attachment) and after 1 hr of in vitro perfusion (retention). The average attachment ranged from 53% to 99.5%. The In-111 activity attached ranged from 10 to 20 ..mu..Ci per graft. A gamma camera with medium energy collimator and two pulse height analyzers for 173 and 247 keV photons with 20% window and an on-line computer was used. Images were obtained in 1.5 zoom mode. The count rate response to a In-111 point source up to 150 ..mu..Ci was linear. The results indicate Hytrel permits better endothelial cell attachment than Gortex and FN coating enhances the strength of attachment to both graft materials. The authors conclude that In-111 Oxine labeling is a reliable method for quantitatively evaluating endothelial cell attachment to vascular graft materials.

  8. Lung scintiscanning in corrective surgery of congenital heart disease, 2

    International Nuclear Information System (INIS)

    Endo, Kaoru

    1981-01-01

    Lung scintiscanning was performed to investigate the distribution of pulmonary blood flow before and after surgery in 30 patients with tetralogy of Fallot. Uniformity of lung scintigram and the derangement of the distribution pattern were observed preoperatively and postoperatively. The results were as follows: 1) Preoperatively, uniformity of lung scintigram was 27.7 - 100% (average 63.4%). It is more necessary to construct the outflow tract in most cases, when the PA/Ao diameter ratio was lower than 0.5 and uniformity of lung scintigram was under 50%. Besides, preoperative uniformity of lung scintigram correlated with the degree of polycythemia. In 3 cases who died after corrective surgery, the value of uniformity of lung scintigram was as low as 33.3 - 61.1%. 2) Preoperative pulmonary blood flow disturbances were found in 50% of 30 cases. In all of the cases without pulmonary blood flow disturbances, total correction was successfully performed. On the other hand, in cases with pulmonary blood flow disturbances, the result of total correction was not satisfactory. 3) In cases with the slight and moderately deranged distribution preoperatively, postoperative follow up study by scintiscanning at 1 to 2 months after surgery showed considerately more improvement of pulmonary blood flow. (author)

  9. Hyperfine interactions in {sup 111}Cd-doped lutetium sesquioxide

    Energy Technology Data Exchange (ETDEWEB)

    Errico, L.A.; Renteria, M.; Bibiloni, A.G.; Requejo, F.G. [Universidad Nacional de La Plata, Programa TENAES (CONICET), Departamento de Fisica, Facultad de Ciencias Exactas (Argentina)

    1999-09-15

    We report here first Perturbed Angular Correlation (PAC) results of the electric field gradient (EFG) characterisation at {sup 111}Cd impurities located at both non-equivalent cation sites of the bixbyite structure of Lutetium sesquioxide, between room temperature (RT) and 1273 K. The comparison with results coming from a systematic {sup 111}Cd PAC study in bixbyites and with point-charge model (PCM) predictions shows the presence of a trapped defect at RT in the neighbourhood of the asymmetric cation site, which is completely removed at T > 623 K. The anomalous EFG temperature dependence in Lu{sub 2}O{sub 3} can be described in the frame of a 'two-state' model with fluctuating interactions, which enables the experimental determination of the acceptor energy level introduced by the Cd impurity in the band-gap of the semiconductor and the estimation of the oxygen vacancy density in the sample.

  10. Adsorbate-induced facetting reconstruction and self-organized domain patterning of vicinal Ag(111) surfaces; Adsorbatinduzierte richtungsabhaengige Facettierung und selbstorganisierte Domaenen-Musterbildung auf vizinalen Ag(111)-Oberflaechen

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Stefan

    2007-02-05

    This thesis investigates structural aspects of adsorbate-induced facetting of vicinal Ag(111) surfaces. It is mainly based on scanning tunneling microscope (STM) and low energy electron diffraction (LEED) experiments performed under UHV conditions. The planar dye-molecule perylene-3,4,9,10-tetracarboxilicacid-dianhydride (PTCDA) adsorbs preferentially at the step edges of the 8.5 Ag(111) vicinal surfaces used in the experiments. It causes a facetting reconstruction by the formation of (111) terraces and facets with a high step density. Moreover, two distinct preferential inclinations of facets were observed, which can only be explained by the selective influence of the adsorbate superstructure. In terms of thermodynamics, the facetting reconstruction can be described as an orientational phase separation, adapted to the constraints of planar surfaces. This concept is capable of explaining the local facetting phenomena. The formalism used predicts an important role of nucleation kinetics. This aspect is taken into account by introducing an additional phase of mobile molecules (2D molecular gas), which cannot be measured directly. Furthermore, strong arguments for the appearance of a critical island size for the PTCDA/ Ag(111) superstructure were found. This work presents structural information of all stable superstructures of PTCDA on vicinal Ag(111) surfaces. Altogether 16 such superstructures were found, 3 of which had been observed and published before. Density and commensurability were found to systematically depend on the step-structure. The two preferred inclinations of facets are related to two characteristic types of domain boundaries of the herringbone superstructure to the adjacent (111)-terrace. On the (111) terraces, small islands of metastable superstructures were found. Facets and (111) terraces form a regular grating-like domain pattern with a variable structural width of 5 to 75 nm. STM measurements show direct evidence for a long-range interaction

  11. Effects of ligand priming and multiple-dose injection on tissue uptake of 111In-pentetreotide in rats

    International Nuclear Information System (INIS)

    Breeman, Wout A. P.; Jong, Marion de; Bernard, Bert F.; Bakker, Willem H.; Rolleman, Edgar J.; Kwekkeboom, Kik J.; Visser, Theo J.; Krenning, Eric P.

    1997-01-01

    In patients undergoing somatostatin receptor scintigraphy, treatment with octreotide (Sandostatin[reg]) is usually discontinued 24-48 h before and after injection with the radioligand 111 In-pentetreotide ([ 111 In-DTPA o ]octreotide) (Octreoscan[reg]) because octreotide competes with radioligand for the same receptors. However, Doerr et al. and Soresi et al. reported improved visualization of carcinoid and small cell lung cancer lesions, respectively, during continued octreotide treatment. We found that intravenous administration of unlabeled octreotide to rats inhibited the binding of an optimal dose (0.5 μg) of 111 In-pentetreotide to somatostatin receptors in pancreas and adrenals in a mass- and time-dependent way. Pretreatment with unlabeled octreotide never increased receptor binding of 111 In-pentetreotide. Administration of 100 μg of octreotide decreased receptor-bound radioactivity if given simultaneously with or 10 or 20 min after injection of the radioligand, but had no effect if given 30 min after the radioligand. These findings indicate rapid processing of receptor-bound octreotide and suggest that octreotide treatment of patients undergoing 111 In-pentetreotide scintigraphy may be reinitiated as soon as 1 h after radioligand administration

  12. 21 CFR 111.360 - What are the requirements for sanitation?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What are the requirements for sanitation? 111.360... for Manufacturing Operations § 111.360 What are the requirements for sanitation? You must conduct all manufacturing operations in accordance with adequate sanitation principles. ...

  13. 46 CFR 111.79-15 - Receptacles for refrigerated containers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Receptacles for refrigerated containers. 111.79-15... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-15 Receptacles for refrigerated containers. Receptacles for refrigerated containers must meet one of the following: (a) Each receptacle for refrigerated...

  14. Work in progress: radionuclide imaging of indium-111-labeled eosinophils in mice

    International Nuclear Information System (INIS)

    Runge, V.M.; Rand, T.H.; Clanton, J.A.; Jones, J.P.; Colley, D.G.; Partain, C.L.; James, A.E. Jr.

    1983-01-01

    Eosinophils isolated from peritoneal exudates were labeled with indium-111-oxine and injected intravenously into sensitized mice. They became localized at sites of inflammation produced by intradermal injections of schistosomal antigen or Toxocara canis larvae, whereas labeled neutrophils did not. Intense uptake of eosinophils by normal spleen, liver, and bone marrow was noted, with tracer distribution effectively complete by 5 hours after injection. Indium-111-eosinophil studies appear to be quite sensitive to parasitic inflammatory reactions; in contrast, nonspecific inflammation such as that induced by turpentine causes localization of eosinophils, but to a lesser extent. This technique may be useful in the study of parasitic and allergic disease

  15. New methods of sup(111)In chemical separation

    International Nuclear Information System (INIS)

    Santos, D.F.; Osso Junior, J.A.; Bastos, M.A.V.; Britto, J.L.Q.; Silva, R.F.

    1986-01-01

    The cation exchange and thermochromatography methods for chemical separation of sup(111) In from silver targets are described. The cation exchange method is based on the difference between In and Ag distribution coefficients on cation exchange resin treated with HNO sub(3). The thermochromatography consists of indium diffusion on silver melted after sublimation and posterior condensation. (M.C.K.)

  16. Indium-111 labelled leucocyte scintigraphy in the diagnosis of inflammatory disease

    International Nuclear Information System (INIS)

    Roevekamp, M.H.

    1982-01-01

    The purpose of this study was to evaluate the diagnostic usefulness of indium-111 oxinate labelled autologous leucocytes in inflammatory disease. Chapter I provides an outline of the theoretical aspects of leucocyte labelling with indium-111 oxinate, as well as giving a description of the labelling method and scintigraphic technique and of the in-vitro and in-vivo studies performed to evaluate the method. In Chapter II details are given of the initial results obtained in a pilot study. A high false-negative rate led to modification of the labelling technique. The results obtained in patients suspected of intra-abdominal or retroperitoneal located inflammatory lesions are described in Chapter III. Chapter IV contains the description of an indium-111-leucocyte-99mTc-Sn-colloid computer-assisted subtraction technique for a better evaluation of patients suspected of an upper-abdominal inflammatory process. In Chapter V the study performed in patients after arterial reconstructive surgery is described, and the results obtained in patients suspected of an infected orthopaedic prosthesis are given in Chapter VI. Finally the characteristics of the different types of inflammatory responses is reviewed. (Auth.)

  17. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    International Nuclear Information System (INIS)

    Smith, S.L.; Wastie, M.L.; Forster, I.

    2001-01-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of 99 Tc m -MDP bone scintigraphy. METHOD: A retrospective study of all patients having a 99 Tc m -MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  18. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L.; Wastie, M.L.; Forster, I

    2001-03-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of{sup 99}Tc{sup m}-MDP bone scintigraphy. METHOD: A retrospective study of all patients having a{sup 99}Tc{sup m}-MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  19. Kinetics, distribution, and sites of destruction of canine blood platelets with In-111 oxine

    International Nuclear Information System (INIS)

    Loetter, M.G.; Badenhorst, P.N.; duP Heyns, A.; Van Reenen, O.R.; Pieters, H.; Minnaar, P.C.

    1980-01-01

    In five normal dogs we have studied the survival, tissue distribution, and fate of autologous platelets labeled with indium-111 oxine. The methods include blood sampling, computer-assisted scintigraphy, and whole-body profile scanning. Mean In-111-platelet recovery in the circulation was 45 +- 22.5 (s.d.) and survival 124.6 +- 10.5 h. Platelet survival curves fitted a linear function best. Initially platelets pooled rapidly in the spleen with a single exponential function, and at zero-time equilibrium (35 +- 4)% of the injected In-111 was located in this organ. Early hepatic uptake was also significant, and constituted (20 +- 4)% of total-body radioactivity. As labeled platelets disappeared from the circulation, In-111 activity in the spleen increased progressively and linearly to reach (59 +- 9)% of the body activity at 120 h. Hepatic radioactivity decreased with time but to a lesser extent than that of the heart. The results indicate that in the dog the major site of destruction of platelets is the spleen, with the liver playing a less important role

  20. Influence of the narrow {111} planes on axial and planar ion channeling.

    Science.gov (United States)

    Motapothula, M; Dang, Z Y; Venkatesan, T; Breese, M B H; Rana, M A; Osman, A

    2012-05-11

    We report channeling patterns where clearly resolved effects of the narrow {111} planes are observed in axial and planar alignments for 2 MeV protons passing through a 55 nm [001] silicon membrane. At certain axes, such as and , the offset in atomic rows forming the narrow {111} planes results in shielding from the large potential at the wide {111} planes, producing a region of shallow, asymmetric potential from which axial channeling patterns have no plane of symmetry. At small tilts from such axes, different behavior is observed from the wide and narrow {111} planes. At planar alignment, distinctive channeling effects due to the narrow planes are observed. As a consequence of the shallow potential well at the narrow planes, incident protons suffer dechanneled trajectories which are excluded from channeling within the wide planes, resulting in an anomalously large scattered beam at {111} alignment.

  1. Use of a new In-111-labeled solid meal for confirmation of the lag phase of gastric emptying

    International Nuclear Information System (INIS)

    Maurer, A.H.; Knight, L.S.; Siegel, J.A.; Scopinaro, F.; Perri, J.A.; Krevsky, B.; Fisher, R.S.; Malmud, L.S.

    1986-01-01

    It has been argued that the appearance of a lag phase in Tc-99m (140 keV) anterior gastric emptying (GE) studies may be artifactual. Since gastric emptying with In-111 (247 keV) is less dependent on attenuation, we have developed a new In-111 meal. Two eggs are mixed with In-111 oxine, cooked thoroughly, and eaten between two pieces of toast. In vitro stability was studied by incubating the In-111 egg in human gastric juice at 37 0 C for 3 hours (97.0% +- 0.6% was bound). In five normal volunteers the mean t1/2 for gastric emptying was 87 +- 12 minutes. This was not significantly different from the Tc-99m normal value (77 +- 10 minutes) we have measured. A lag phase for the In-111-containing egg was present in each case (mean, 40 +- 8 minutes). The authors conclude that an In-111 meal can confirm the presence of a physiologic lag phase

  2. Radionuclides and inflammatory bowel diseases: 99mTc-sucralfate and 111 In-tropolonate-granulocytes

    International Nuclear Information System (INIS)

    Deveaux, M.; Macaigne, O.; Lecouffe, P.; Hossein-Foucher, CL.; Meuriot, S.; Venel, H.; Cortot, A.; Marchandise, X.

    1989-01-01

    111 In-tropolonate-granulocytes (G- 111 In) study was performed in 16 patients with inflammatory bowel disease (IBD). Images were obtained 3 h and 20 h post-injection. Counting of four days feacal excretion was more accurately expressed as daily intestinal granulocytes clearance. The day before, 12 of the patients had a sucralfate- 99m Tc scan (S- 99m Tc). Correlation between radioendoscopic data and S- 99m Tc scans was poor in 9 instances and there was no correlation between scan activity index and clinical and biological assessment. Correlation between G- 111 In scans and radioendoscopic data was excellent in 13 instances. Scan activity index was correlated with the Best index and with the intestinal alpha-1-antitrypsine clearance. Faecal excretion (range. 1 - 40%) and daily intestinal granulocytes clearance values (range. 03 - 50 milliards) were only correlated with protein loss parameters. So S- 99m Tc scan does not appear to be reliable, while intestinal G- 111 In clearance, not such easy to perform, can give an accurate assessment of IBD activity [fr

  3. Quantitative evaluation of indium-111 (In-111) octreotide pituitary activity: Comparison in patient with and without pituitary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, P.; Waxman, A.; Nguyen, K. [Cedars-Sinai Medical Center, Los Angeles, CA (United States)] [and others

    1995-05-01

    Indium 111 Octreotide is known to detect pituitary tumors. Variable low level pituitary activity has been reported in pts. with no demonstrable pituitary tumors. To our knowledge, there have been no studies which quantitatively categorize pituitary activity with respect to distinguishing normal subject from pts. with pituitary tumors. 13 pts. with proven, treated acromegaly were included, as well as 15 pts. with no history of pituitary disorder. Both groups underwent SPECT In-111 scintigraphy 24 hours post-injection Average count per pixel ratios were obtained for the pituitary/calvarium (P/C) and pituitary/brain (P/B) regions. 10 pts. with acromegaly underwent growth hormone (GH) measurements 2 hours post-glucose load. Statistical correlation between growth hormone levels using P/C and P/B ratios were obtained. P/C ratios, as well as P/B ratios demonstrated high correlation with serum GH levels correlation coefficient(r)= .717 for P/C p<0.05, and correlation coefficient(r) = 0.828 for P/B ratios p<0.005. P/C ratios and P/B ratios for controls correlated closely with the upper level of normal predicted by P/C or P/B ratios as a function of serum growth hormone found in patients with acromegaly. Somatostatin receptor SPECT scintigraphy of the pituitary and appropriate quantitation can predict patients with growth hormone secreting tumors.

  4. Ethylene Glycol Adsorption and Reaction over CeOX(111) Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    T Chen; D Mullins

    2011-12-31

    This study reports the interaction of ethylene glycol with well-ordered CeO{sub x}(111) thin film surfaces. Ethylene glycol initially adsorbs on fully oxidized CeO{sub 2}(111) and reduced CeO{sub 2-x}(111) through the formation of one C-O-Ce bond and then forms a second alkoxy bond after annealing. On fully oxidized CeO{sub 2}(111) both recombination of ethylene glycol and water desorption occur at low temperature leaving stable -OCH{sub 2}CH{sub 2}O- (ethylenedioxy) intermediates and oxygen vacancies on the surface. This ethylenedioxy intermediate goes through C-C bond scission to produce formate species which then react to produce CO and CO{sub 2}. The formation of water results in the reduction of the ceria. On a reduced CeO{sub 2-x}(111) surface the reaction selectivity shifts toward a dehydration process. The ethylenedioxy intermediate decomposes by breaking a C-O bond and converts into an enolate species. Similar to the reaction of acetaldehyde on reduced CeO{sub 2-x}(111), the enolate reacts to produce acetaldehyde, acetylene, and ethylene. The loss of O from ethylene glycol leads to a small amount of oxidation of the reduced ceria.

  5. Preclinical evaluation of [ 111 In]-DOTA-trastuzumab for clinical trials

    Directory of Open Access Journals (Sweden)

    Behrouz Alirezapour

    2014-01-01

    Full Text Available Context: Herceptin and its fragments have been radiolabeled and used in the imaging of human epidermal growth factor receptor 2 (HER2/neu-positive tumors and development of diagnostic kits is of great importance in radiopharmacy. Aims: In this study, 111 In-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-trastuzumab ( 111 In-DOTA-trastuzumab was successively prepared and evaluated for ultimate use in the HER2 antigen imaging in oncology. Settings and Design: The conjugate was prepared, labeled and evaluated using in vitro (radioimmunoassay [RIA], enzyme-linked immunosorbent assay (ELISA, stability, binding, internalization/in vivo (bio-distribution, single-photon emission computed tomography [SPECT] experiments. Materials and Methods: 111 In-DOTA-trastuzumab was prepared followed by determination of radiochemical purity (RCP, integrity of protein, immunoreactivity of radiolabeled antibody with HER2/neu antigen (by SkBr3 cell line binding and RIA methods were determined followed by stability tests, internalization studies and the tissue bio-distribution determination in wild-type rats as well as SPECT imaging in SkBr3-bearing mice. Statistical Analysis Used: All values were expressed as mean ± standard deviation (mean ± SD and the data were compared using Student′s t-test. Statistical significance was defined as P 95 ± 0.5%, S.A. 5.3 μCi/μg with the average number of chelators per antibody of 6:1 showing significant immune-reactivity retention using ELISA. In vitro stability was >90% in phosphate buffered saline and 80 ± 0.5% in serum over 48 h. Cell binding was significant (>0.79. In vitro internalization reached up to %12-13 in 10 h. Significant tumor uptake was observed. Conclusions: In vitro and in vivo/SPECT imaging in SkBr3-bearing mice demonstrated that 111 In-DOTA-trastuzumab is a potential compound for molecular imaging of SPECT for diagnosis and follow-up of HER2 expression in oncology.

  6. Auger line shape changes in epitaxial (111)Pd/(111)Cu films

    Energy Technology Data Exchange (ETDEWEB)

    Chao, S S; Knabbe, E A; Vook, R W

    1980-01-01

    Epitaxial Pd films ranging in thickness from a few tenths of a monolayer up to many monolayers were formed on (111)Cu substrate films at room temperature under uhv conditions. The growth of these Pd films was monitored in situ by Auger electron spectroscopy. The line profiles of the Cu MMM (61 eV) and Pd MVV (329 eV) AES doublets varied significantly with the amount of Pd deposited. A new measure of the AES doublet line profile, called the R-factor, was defined. A graph of R/sub Pd/ versus Pd film thickness shows a sharp decline with increasing thickness. Superimposed on the major trends is a cyclical variation. A corresponding periodicity in R/sub Cu/ was observed for the Cu MMM (61 eV) AES doublet. The results suggest that the R-factor provides a direct measure of changes in the electronic structures of the overgrowth and substrate films as the former thickens by a layer-growth mechanism.

  7. NO on {CoO(111) }/{Co(0001) }: hydroxyl assisted adsorption

    Science.gov (United States)

    Hassel, M.; Freund, H.-J.

    1995-02-01

    We have investigated the structure of epitaxially grown CoO(111) on Co(0001) and the adsorption of NO on this surface using electron spectroscopic methods. The procedure of oxidation of a cobalt surface to get a single-crystal oxide surface has been chosen for two reasons: first, charging of the sample can be avoided when preparing oxide surfaces of only 20-30 Å thickness. Second, the (111) surface of the ionic rocksalt structure is thermodynamically unstable and thus not otherwise easily accessible for surface studies. We show that the (111) surface is terminated by hydroxyl groups which we think stabilize the surface in the same way as the NiO(111) surface is stabilized [F. Rohr et al., Surf. Sci. 315 (1994) L297; D. Cappus et al., Chem. Phys. 177 (1993) 533], and that the adsorption of NO is affected by the presence of OH.

  8. The Trails of Superluminal Jet Components in 3C 111

    Science.gov (United States)

    Kadler, M.; Ros, E.; Perucho, M.; Kovalev, Y. Y.; Homan, D. C.; Agudo, I.; Kellermann, K. I.; Aller, M. F.; Aller, H. D.; Lister, M. L.; hide

    2007-01-01

    The parsec-scale radio jet of the broad-line radio galaxy 3C 111 has been monitored since 1995 as part of the 2cm Survey and MOJAVE monitoring observations conducted with the VLBA. Here, we present results from 18 epochs of VLBA observations of 3C 111 and from 18 years of radio flux density monitoring observations conducted at the University of Michigan. A major radio flux-density outburst of 3C 111 occurred in 1996 and was followed by a particularly bright plasma ejection associated with a superluminal jet component. This major event allows us to study a variety of processes associated with outbursts of radio-loud AGN in much greater detail than possible in other cases: the primary perturbation gives rise to the formation of a forward and a backward-shock, which both evolve in characteristically different ways and allow us to draw conclusions about the workflow of jet-production events; the expansion, acceleration and recollimation of the ejected jet plasma in an environment with steep pressure and density gradients are revealed; trailing components are formed in the wake of the primary perturbation as a result of Kelvin- Helmholtz instabilities from the interaction of the jet with the external medium. The jet-medium interaction is further scrutinized by the linear-polarization signature of jet components traveling along the jet and passing a region of steep pressure/density gradients.

  9. 46 CFR 111.105-45 - Vessels carrying agricultural products.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Vessels carrying agricultural products. 111.105-45... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-45 Vessels carrying agricultural products. (a) The following areas are Class II, Division 1, (Zone 10 or Z) locations on vessels...

  10. 41 CFR 101-1.111 - Retention of FPMR amendments.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Retention of FPMR amendments. 101-1.111 Section 101-1.111 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101...

  11. Simulating Linear Sweep Voltammetry from First-Principles: Application to Electrochemical Oxidation of Water on Pt(111) and Pt3Ni(111)

    DEFF Research Database (Denmark)

    Viswanathan, Venkatasubramanian; Hansen, Heine Anton; Rossmeisl, Jan

    2012-01-01

    Cyclic voltammetry is a fundamental experimental method for characterizing adsorbates on electrochemical surfaces. We present a model for the electrochemical solid–liquid interface, and we simulate the linear sweep voltammogram of the electrochemical oxidation of H2O on Pt(111) and Pt3Ni(111...

  12. Lung scintiscanning in corrective surgery of congenital heart disease, 2. Tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Endo, K. (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1981-06-01

    Lung scintiscanning was performed to investigate the distribution of pulmonary blood flow before and after surgery in 30 patients with tetralogy of Fallot. Uniformity of lung scintigram and the derangement of the distribution pattern were observed preoperatively and postoperatively. The results were as follows: 1) Preoperatively, uniformity of lung scintigram was 27.7 - 100% (average 63.4%). It is more necessary to construct the outflow tract in most cases, when the PA/Ao diameter ratio was lower than 0.5 and uniformity of lung scintigram was under 50%. Besides, preoperative uniformity of lung scintigram correlated with the degree of polycythemia. In 3 cases who died after corrective surgery, the value of uniformity of lung scintigram was as low as 33.3 - 61.1%. 2) Preoperative pulmonary blood flow disturbances were found in 50% of 30 cases. In all of the cases without pulmonary blood flow disturbances, total correction was successfully performed. On the other hand, in cases with pulmonary blood flow disturbances, the result of total correction was not satisfactory. 3) In cases with the slight and moderately deranged distribution preoperatively, postoperative follow up study by scintiscanning at 1 to 2 months after surgery showed considerately more improvement of pulmonary blood flow.

  13. Evaluation of indium-111-2-mercaptopyridine-N-oxide for labeling leukocytes in plasma: a kit preparation

    International Nuclear Information System (INIS)

    Thakur, M.L.; McKenney, S.L.; Park, C.H.

    1985-01-01

    Pure neutrophils, lymphocytes, and mixed leukocytes have been labeled in vitro with 111 In chelated to a nontoxic, water soluble agent 2-mercaptopyridine-N-oxide (Merc). Cells were labeled in isotonic salt-balanced medium with preformed [ 111 In]Merc, or in 0.5 ml autologous plasma by incubation with dry Merc first and then with 111 In. The latter method facilitated a kit procedure that required 2 μg dry Merc when acid citrate dextrose was used as anticoagulant or 20μg when heparin was used. Labeling efficiency was dependent on cell concentration and pH. Labeled cells accumulated avidly in experimental abscesses. In dogs, the liver uptake of labeled cells was only 18.8% compared to that of 48.5% when cells were labeled with [ 111 In] oxine

  14. The spleen-liver uptake ratio in liver scan: review of its measurement and correlation between hemodynamical changes of the liver in portal hypertension

    International Nuclear Information System (INIS)

    Lee, S. Y.; Chung, Y. A.; Chung, H. S.; Lee, H. G.; Kim, S. H.; Chung, S. K.

    1999-01-01

    We analyzed correlation between changes of the Spleen-Liver Ratio in liver scintigram and hemodynamical changes of the liver in overall grades of portal hypertension by non-invasive, scintigraphic method. And the methods for measurement of the Spleen-Liver Ratio were also reviewed. Hepatic scintiangiograms for 120 seconds with 250-333 MBq of 99mTc-Sn-phytate followed by liver scintigrams were performed in 62 patients group consisted with clinically proven norma and various diffuse hepatocellular diseases. Hepatic Perfusion indices were calculated from the Time-Activity Curves of hepatic scintiangiograms. Each Spleen-Liver Ratios of maximum, average and total counts within ROIs of the liver and spleen from both anterior and posterior liver scintigrams and their geometrical means were calculated. Linear correlations between each Spleen-Liver Ratios and Hepatic Perfusion indices were evaluated. There was strong correlation (y=0.0002x 2 -0.0049x+0.2746, R=0.8790, p<0.0001) between Hepatic Perfusion Indices and Spleen-Liver Ratios calculated from posterior maxium counts of the liver scintigrams. Weaker correlations with either geometrical means of maximum and average count methods (R=0.8101, 0.7268, p<0.0001) or average counts of both posterior and anterior veiws (R=0.8134, 0.6200, p<0.0001) were noted. We reconfirmed that changes of Spleen-Liver Ratio in liver scintigrams represent hemodynamical changes in portal hypertension of diffuse hepatocellular diseases. Among them, the posterior Spleen-Liver Ratio measured by maximum counts will give the best information. And matching with Hepatic Perfusion index will be another useful index to evaluate characteristics splenic extraction coefficient of a certain radiocolloid for liver scintigram

  15. Evaluation of In-111 DTPA-paclitaxel scintigraphy to predict response on murine tumors to paclitaxel

    International Nuclear Information System (INIS)

    Inoue, Tomio; Li, C.; Yang, D.J.

    1999-01-01

    Our goal was to determine whether scintigraphy with 111 In-DTPA-paclitaxel could predict the response to chemotherapy with paclitaxel. Ovarian carcinoma (OCA 1), mammary carcinoma (MCA-4), fibrosarcoma (FSA) and squamous cell carcinoma (SCC VII) were inoculated into the thighs of female C3Hf/Kam mice. Mice bearing 8 mm tumors were treated with paclitaxel (40 mg/kg). The growth delay, which was defined as the time in days for tumors in the treated groups to grow from 8 to 12 mm in diameter minus the time in days for tumors in the untreated control group to reach the same size, was measured to determine the effect of paclitaxel on the tumors. Sequential scintigraphy in mice bearing 10 to 14 mm tumors was conducted at 5, 30, 60, 120, 240 min and 24 hrs postinjection of 111 In-DTPA-paclitaxel (3.7 MBq) or 111 In-DTPA as a control tracer. The tumor uptakes (% injection dose/pixel) were determined. The growth delay of OCA 1, MCA-4, FSA and SCC VII tumors was 13.6, 4.0, -0.02 and -0.28 days, respectively. In other words, OCA 1 and MCA-4 were paclitaxel-sensitive tumors, whereas FSA and SCC VII were paclitaxel-resistant tumors. The tumor uptakes at 24 hrs postinjection of In-111 DTPA paclitaxel of OCA 1, MCA-4, FSA and SCC VII were 1.0 x 10 -3 , 1.6 x 10 -3 , 2.2 x 10 -3 and 9.0 x 10 -3 % injection dose/pixel, respectively. There was no correlation between the response to chemotherapy with paclitaxel and the tumor uptakes of 111 In-DTPA-paclitaxel. Scintigraphy with 111 In-DTPA-paclitaxel could not predict the response to paclitaxel chemotherapy. Although there was significant accumulation of the paclitaxel in the tumor cells, additional mechanisms must be operative for the agent to be effective against the neoplasm. 111 In-DTPA-paclitaxel activity is apparently different from that of paclitaxel with Cremophor. (author)

  16. In vitro detection of mdr1 mRNA in murine leukemia cells with 111In-labeled oligonucleotide

    International Nuclear Information System (INIS)

    Bai Jingming; Yokoyama, Kunihiko; Kinuya, Seigo; Michigishi, Takatoshi; Tonami, Norihisa; Shiba, Kazuhiro; Matsushita, Ryo; Nomura, Masaaki

    2004-01-01

    The feasibility of intracellular mdr1 mRNA expression detection with radiolabeled antisense oligonucleotide (ODN) was investigated in the murine leukemia cell line, P388/S, and its subclonal, adriamycin-resistant cell line, P388/R. The expression level of mdr1 mRNA was analyzed by reverse transcription-polymerase chain reaction (RT-PCR). Existence of the multidrug resistance (MDR) phenomenon was assessed via cellular uptake of 99m Tc-sestamibi (MIBI), a known substrate for P-glycoprotein. A 15-mer phosphorothioate antisense ODN complementary to the sequences located at -1 to 14 of mdr1 mRNA and its corresponding sense ODN were conjugated with the cyclic anhydride of diethylene triamine penta-acetic acid (cDTPA) via an amino group linked to the terminal phosphate at the 5' end at pH 8-9. The DTPA-ODN complexes at concentrations of 0.1-17.4 μMwere reacted with 111 InCl 3 at pH 5 for 1 h. The hybridization affinity of labeled ODN was evaluated with size-exclusion high-performance liquid chromatography following incubation with the complementary sequence. Cellular uptake of labeled ODN was examined in vitro. Furthermore, enhancing effects of synthetic lipid carriers (Transfast) on transmembrane delivery of ODN were assessed. P388/R cells displayed intense mdr1 mRNA expression in comparison with P388/S cells. 99m Tc-MIBI uptake in P388/S cells was higher than that in P388/R cells. Specific radioactivity up to 1,634 MBq/nmol was achieved via elevation of added radioactivity relative to ODN molar amount. The hybridization affinity of antisense 111 In-ODN was preserved at approximately 85% irrespective of specific activity. Cellular uptake of antisense 111 In-ODN did not differ from that of sense 111 In-ODN in either P388/S cells or P388/R cells. However, lipid carrier incorporation significantly increased transmembrane delivery of 111 In-ODN; moreover, specific uptake of antisense 111 In-ODN was demonstrated in P388/R cells. Radiolabeling of ODN at high specific

  17. He/Ar-atom scattering from molecular monolayers: C{sub 60}/Pt(111) and graphene/Pt(111)

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y; Sugawara, C; Satake, Y; Yokoyama, Y; Okada, R; Nakayama, T; Sasaki, M [Institute of Applied Physics, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki (Japan); Kondo, T; Oh, J; Nakamura, J [Institute of Material Science, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki (Japan); Hayes, W W [Department of Physics and Astronomy, Clemson University, Clemson, SC 29634 (United States)

    2010-08-04

    Supersonic He and Ar atomic beam scattering from C{sub 60} and graphene monolayers adsorbed on a Pt(111) surface are demonstrated in order to obtain detailed insight into a gas-molecule collision that has not been studied in detail so far. The effective masses and phonon spectral densities of the monolayers seen by different projectiles are discussed based on classical models such as the hard cube model and the recently developed smooth surface model. Large effective masses are deduced for both the monolayers, suggesting collective effects of surface atoms in the single collision event. The effective Debye temperature of graphene was found to be similar to that reported in highly oriented pyrolytic graphite (HOPG), indicating that the graphene is decoupled well from the Pt substrate. A much smaller Debye-Waller factor was found for the C{sub 60} layer, probably reflecting the strong C{sub 60}-Pt(111) interaction.

  18. In situ Oxidation of Ultrathin Silver Films on Ni(111)

    International Nuclear Information System (INIS)

    Meyer, A.; Flege, I.; Senanayake, S.; Kaemena, B.; Rettew, R.; Alamgir, F.; Falta, J.

    2011-01-01

    Oxidation of silver films of one- and two-monolayer thicknesses on the Ni(111) surface was investigated by low-energy electron microscopy at temperatures of 500 and 600 K. Additionally, intensity-voltage curves were measured in situ during oxidation to reveal the local film structure on a nanometer scale. At both temperatures, we find that exposure to molecular oxygen leads to the destabilization of the Ag film with subsequent relocation of the silver atoms to small few-layer-thick silver patches and concurrent evolution of NiO(111) regions. Subsequent exposure of the oxidized surface to ethylene initiates the transformation of bilayer islands back into monolayer islands, demonstrating at least partial reversibility of the silver relocation process at 600 K.

  19. HREM of metallized {111} iron oxide nanoparticle surfaces

    International Nuclear Information System (INIS)

    Lovely, G R; Brown, A P; Brydson, R; Kirkland, A I; Meyer, R; Chang, L Y; Jefferson, D A; Falke, M; Bleloch, A

    2006-01-01

    Mixed phase Fe 3 O 4 - γ-Fe 2 O 3 (magnetite-maghemite) nanoparticles have been fabricated by colloidal routes. HR(S)TEM images, taken on both aberration corrected and uncorrected (S)TEMs, and indirect reconstruction of images of the nanoparticles show the presence of {111} facets that terminate with enhanced contrast. This extra contrast is shown to be real and is due to additional octahedral cations occupying the {111} surfaces

  20. Motion of 1/3⟨111⟩ dislocations on Σ3 {112} twin boundaries in nanotwinned copper

    Science.gov (United States)

    Lu, N.; Du, K.; Lu, L.; Ye, H. Q.

    2014-01-01

    The atomic structure of Σ3 {112} ITBs in nanotwinned Cu is investigated by using aberration-corrected high resolution transmission electron microscopy (HRTEM) and in situ HRTEM observations. The Σ3 {112} ITBs are consisted of periodically repeated three partial dislocations. The in situ HRTEM results show that 1/3[111] partial dislocation moves on the Σ3 {112} incoherent twin boundary (ITB), which was accompanied by a migration of the ITB. A dislocation reaction mechanism is proposed for the motion of 1/3[111] Frank partial dislocation, in which the 1/3[111] partial dislocation exchanges its position with twin boundary dislocations in sequence. In this way, the 1/3[111] dislocation can move on the incoherent twin boundary in metals with low stacking fault energy. Meanwhile, the ITB will migrate in its normal direction accordingly. These results provide insight into the reaction mechanism of 1/3[111] dislocations and ITBs and the associated migration of ITBs.

  1. Evaluation of indium-111 colloid for radionuclide imaging of the abdominal lymph nodes

    International Nuclear Information System (INIS)

    Vieras, F.; Hamilton, R.F.; Grissom, M.P.; Kiepffer, R.F.; Vandergrift, J.F.

    1981-01-01

    The experimental evaluation of indium-111 colloid for imaging the para-aortic lymph nodes in animals is described and preliminary results obtained in human subjects. Serial lymphatic scintigraphy performed in beagle dogs following bilateral pedal subcutaneous injections of indium-111 colloid revealed good para-aortic lymph node visualization. A normal migration pattern of indium-111 colloid was also observed in human subjects following subcutaneous injection in the feet; there was clear visualization of the ileo-inguinal and para-aortic lymph nodes. Organ distribution studies for indium-111 colloid were performed in rats following unilateral pedal subcutaneous injection in rats; these results were used for calculating radiation dose estimates to various organs. The study demonstrates the feasibility of using 111 In-colloid clinically for abdominal lymphatic scintiography for the use of sup(99m)Tc-labelled colloids results in lower radiation doses. (U.K.)

  2. 111In and 90Y labelled peptide radiopharmaceuticals for diagnosis and therapy

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.L.; Castiglia, S.G. de

    2004-01-01

    Full text: The application of 111In-labelled octreotide to target somatostatin receptors on tumour cells has gained acceptance as a diagnostic procedure for demonstrating neuroendocrine and other SSTR-positive tumors. A further advance in the field of somatostatin analogues is the development of macrocyclic chelators that also bind beta particle emitters like 90Y and 177Lu. [90Y-DOTA, Tyr3] octreotide and [177Lu-DOTA, Tyr3] octreotate are currently being tried as the therapeutic agents. The aim of this work was to label two somatostatin analogues (Tyr3 Octreotide and Lanreotide) with 111In and 90Y using DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) as a chelating agent. DOTA in the form of the tri-t-butyl ester was coupled to the Lys5 (BOC) protected Tyr3octreotide and Lys5 (BOC) protected lanreotide in N,N-dimethylformamide, in a three-step reaction involving conjugation, using HATU and diisopropylethylamine as coupling reagents, de-protection with trifluoroacetic and HPLC purification of the conjugates. The DOTALAN and DOTATOC were labelled with 111In and 90Y and assayed by HPLC. In both cases solutions of gentisic acid in sodium acetate 0.4M pH=5.0 and conjugated peptides were added to the 111In or 90Y chloride. The final solution was heated at 90 deg. C for 25 minutes. We tried different amounts of the two peptide complexes per mCi of 111In/90Y and quality control of the labelled products was performed with the following HPLC system: reverse phase column, flow rate 1ml-min, UV/radiometric detection and a gradient solvent: solvent A: acetonitrile, solvent B: water TFA 0.1%, gradient: 0-3min 100% B, linear increase of eluent A to 50% from 3-13 min, 13-18 min 50% A, 18-20 min linear increase of eluent A to 70%. Serum stability was determined after 4 and 24 hr. incubation of the labeled peptide in human serum at 37 deg. C. After precipitation of proteins with acetonitrile the incubation mixture was analyzed by HPLC. Normal Wistar rats were

  3. Development of a new method for 111In production through the irradiation of Cd with protons

    International Nuclear Information System (INIS)

    Lion, Luciana Farias de

    2002-01-01

    111 In (t 1/2 = 2,83 d) has favourable characteristics for its use in Nuclear Medicine and it is one of radioisotopes of interest of Brazilian physicians. 111 In decays 100% by electron capture with emission of gamma rays of 171.28 and 245.38 keV that are in the maximum detection range of equipment used for diagnosis. 111 In has been broadly used in molecules labelling such as monoclonal antibodies and peptides for tumour localization. A new method of 111 In production was developed through the irradiation of Cd with protons. The chosen nuclear reaction, 112 Cd(p,2n) 11l n, has suitable yields for a routine production by using an enriched Cd target. This work was done with natural Cd targets that were prepared by electroplating of CdS0 4 solution in a copper/nickel backing. The irradiations were made at CV-28 and Cyclone 30 Cyclotrons at IPEN-CNEN/SP Chemical separation was performed by thermal diffusion technique in which the irradiated targets were heated up to 300 deg C. Then, the irradiated targets were immersed in acetic acid for extraction of 111 In and the collected solution was purified in anionic resin. The final solution of 111 In presented appropriated chemical and radionuclidic purities for its use in Nuclear Medicine, 114m In (t 1/2 = 49.5 d) was the main radionuclide impurity produced by activation of natural Cd, This work presents a new method for production of 111 In, where the chemical separation was done by a non-destructive technique of the target that can be easily automated and finally, it has purities and yields suitable for routine production at IPEN-CNEN/SP. (author)

  4. 46 CFR 111.30-25 - Alternating-current ship's service switchboards.

    Science.gov (United States)

    2010-10-01

    ... connected generator, each switchboard must have the following: (1) A circuit breaker that meets § 111.12-11 and § 111.50-5. (2) A disconnect switch or link for each generator conductor, except a switchboard having a draw-out or plug-in type generator circuit breaker that disconnects: (i) Each generator...

  5. 15 CFR 27.111 - Criteria for IRB approval of research.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Criteria for IRB approval of research. 27.111 Section 27.111 Commerce and Foreign Trade Office of the Secretary of Commerce PROTECTION OF... subjects are reasonable in relation to anticipated benefits, if any, to subjects, and the importance of the...

  6. 11 CFR 111.38 - Can the respondent appeal the Commission's final determination?

    Science.gov (United States)

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Can the respondent appeal the Commission's final determination? 111.38 Section 111.38 Federal Elections FEDERAL ELECTION COMMISSION GENERAL... determination under 11 CFR 111.37, the respondent may submit a written petition to the district court of the...

  7. Pharmacokinetic analysis of 111 in-labeled liposomal Doxorubicin in murine glioblastoma after blood-brain barrier disruption by focused ultrasound.

    Directory of Open Access Journals (Sweden)

    Feng-Yi Yang

    Full Text Available The goal of this study was to evaluate the pharmacokinetics of targeted and untargeted (111In-doxorubicin liposomes after these have been intravenously administrated to tumor-bearing mice in the presence of blood-brain barrier disruption (BBB-D induced by focused ultrasound (FUS. An intracranial brain tumor model in NOD-scid mice using human brain glioblastoma multiforme (GBM 8401 cells was developed in this study. (111In-labeled human atherosclerotic plaque-specific peptide-1 (AP-1-conjugated liposomes containing doxorubicin (Lipo-Dox; AP-1 Lipo-Dox were used as a microSPECT probe for radioactivity measurements in the GBM-bearing mice. Compared to the control tumors treated with an injection of (111In-AP-1 Lipo-Dox or (111In-Lipo-Dox, the animals receiving the drugs followed by FUS exhibited enhanced accumulation of the drug in the brain tumors (p<0.05. Combining sonication with drugs significantly increased the tumor-to-normal brain doxorubicin ratio of the target tumors compared to the control tumors. The tumor-to-normal brain ratio was highest after the injection of (111In-AP-1 Lipo-Dox with sonication. The (111In-liposomes micro-SPECT/CT should be able to provide important information about the optimum therapeutic window for the chemotherapy of brain tumors using sonication.

  8. {sup 111}In-anti-F4/80-A3-1 antibody: a novel tracer to image macrophages

    Energy Technology Data Exchange (ETDEWEB)

    Terry, Samantha Y.A. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); King' s College London, St Thomas' Hospital, Department of Imaging Chemistry and Biology, London (United Kingdom); Boerman, Otto C.; Gerrits, Danny; Franssen, Gerben M.; Oyen, Wim J.G. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Metselaar, Josbert M. [University of Twente, Targeted Therapeutics, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands); Lehmann, Steffi; Gerdes, Christian A. [Roche Innovation Center Zurich, Roche Pharmaceutical Research and Early Development (pRED), Zurich (Switzerland); Abiraj, Keelara [Roche Innovation Center Basel, Roche Pharmaceutical Research and Early Development (pRED), Basel (Switzerland)

    2015-08-15

    Here, the expression of F4/80 on the cell surface of murine macrophages was exploited to develop a novel imaging tracer that could visualize macrophages in vivo. The immunoreactive fraction and IC{sub 50} of anti-F4/80-A3-1, conjugated with diethylenetriaminepentaacetic acid (DTPA) and radiolabelled with {sup 111}In, were determined in vitro using murine bone marrow-derived macrophages. In vivo biodistribution studies were performed with {sup 111}In-anti-F4/80-A3-1 and isotype-matched control antibody {sup 111}In-rat IgG2b at 24 and 72 h post-injection (p.i.) in SCID/Beige mice bearing orthotopic MDA-MB-231 xenografts. In some studies mice were also treated with liposomal clodronate. Macrophage content in tissues was determined immunohistochemically. Micro-single photon emission computed tomography (SPECT)/CT images were also acquired. In vitro binding assays showed that {sup 111}In-anti-F4/80-A3-1 specifically binds F4/80 receptor-positive macrophages. The immunoreactivity of anti-F4/80-A3-1 was 75 % and IC{sub 50} was 0.58 nM. In vivo, injection of 10 or 100 μg {sup 111}In-anti-F4/80-A3-1 resulted in splenic uptake of 78 %ID/g and 31 %ID/g, respectively, and tumour uptake of 1.38 %ID/g and 4.08 %ID/g, respectively (72 h p.i.). Liposomal clodronate treatment reduced splenic uptake of 10 μg {sup 111}In-anti-F4/80-A3-1 from 248 %ID/g to 114 %ID/g and reduced {sup 111}In-anti-F4/80-A3-1 uptake in the liver and femur (24 h p.i.). Tracer retention in the blood and tumour uptake increased (24 h p.i.). Tumour uptake of {sup 111}In-anti-F4/80-A3-1 was visualized by microSPECT/CT. Macrophage density in the spleen and liver decreased in mice treated with liposomal clodronate. Uptake of {sup 111}In-rat IgG2b was lower in the spleen, liver and femur when compared to {sup 111}In-anti-F4/80-A3-1. Radiolabelled anti-F4/80-A3-1 antibodies specifically localize in tissues infiltrated by macrophages in mice and can be used to visualize tumours. The liver and spleen act as antigen

  9. Indium-111 oxine labelling of white blood cells

    International Nuclear Information System (INIS)

    Lavender, J.P.; Silvester, D.J.; Goldman, J.; Hammersmith Hospital, London

    1978-01-01

    Following work done by Professor John McAfee and Mathew Thakur at the MRS Cyclotron Unit a method is available for labelling cells with indium-111 which results in a stable intracellular marker. The method uses indium-111-8 hydroxyquinoline (111In oxine) which is a lipoid soluble complex which goes across the cell membrane and results in the deposition of indium into various subcellular structures. It has been applied to various preparations of white cells, platelets and also malignant cells. Autologous granulocytes have been used to identify inflammatory lesions in 35 patients. By similar means autologous lymphocytes can also be labelled and reinfused. Lymphocytes have been shown in animals to circulate from the blood via the lymphatic system and then returning to the blood once more. The same phenomenon can be seen in man using indium labelled lymphocytes. Lymph nodes become visible at between 12 and 18 hours and recirculation of labelled cells can be shown on the blood activity curves. Certain problems arise concerning cell behaviour after labelling which appear due to irradiation of cells rather than chemical toxicity. (author)

  10. High-temperature method of rapid separation of In-111 from irradiated silver targets

    International Nuclear Information System (INIS)

    Mazgaj, Z.; Kolaczkowski, A.; Mikulski, J.; Novgorodov, A.F.; Zielinski, A.; Joint Inst. for Nuclear Research, Dubna

    1990-01-01

    A high-temperature method of separation of In-111 from α-particle activated silver targets was developed. The separation is carried out under reduced pressure, in the atmosphere of HCl and H 2 O vapours. Indium-111, adsorbed on a quartz collector, is washed out quantitatively with 0.1 N HCl. The contaminant, Cd-109 (product of decay of In-109), is removed from the preparation by means of ion-exchange chromatography. 4 tabs., 6 refs. (author)

  11. Quasi-freestanding graphene on Ni(111) by Cs intercalation

    KAUST Repository

    Alattas, Maha Hassan Mohssen

    2017-01-08

    It is of technological interest to achieve quasi-freestanding graphene on a substrate. A possible approach is the intercalation of alkali metal atoms. Cs intercalation between graphene and Ni(111) is investigated using density functional theory, incorporating van der Waals corrections. It is known that direct contact between graphene and Ni(111) perturbs the Dirac states. Cs intercalation restores the linear dispersion characteristic of Dirac fermions, which is in agreement with experiments1, but the Dirac cone is shifted to lower energy, i.e., the graphene sheet is n-doped. Cs intercalation therefore effectively decouples the graphene sheet from the substrate except for a charge transfer. On the other hand, the spin polarization of Ni(111) does not extend through the intercalated atoms to the graphene sheet, for which we find virtually spin-degeneracy.

  12. Immunoscintigraphy using 111In-DTPA labeled monoclonal antibodies: Comparison between ETC and planar imaging

    International Nuclear Information System (INIS)

    Happ, J.; Baum, R.P.; Frohn, J.; Weimer, B.; Hoer, G.; Halbsguth, A.; Lochner, B.; Brandhorst, I.

    1987-01-01

    The present study was done in order to examine if the use of 111 In-DTPA-labeled MAb fragments in place of 131 I-labeled MAb fragments increases the sensitivity of tomographic immunoscintigraphy to reach the level of that of planar imaging techniques. In 11 patients with various primary tumors, local recurrences or metastases [colorectal carcinoma (n=7), ovarian carcinoma (n=2), papillary thyroid carcinoma (n=1), undifferentiated carcinoma of the lung (n=1)], immuniscintigraphy (IS) was carried out using 111 In-DTPA-labeled F(ab') 2 fragments of various MAbs (anti-CEA, OC 125, anti-hTG) and planar and tomographic imaging were compared intraindividually. By conventional diagnostic procedures, the presence of a tumor mass was confirmed (transmission computer tomography, ultrasound) or verified ( 131 I whole-body scintigraphy, histology) in all cases. Immunoscintigraphy was positive in 9 out of 11 cases by ECT and in 10 out of 11 cases by planar imaging. When using 111 In-labeled MAb fragments, intraindividual comparison of ECT and planar imaging resulted in a similar sensitivity. The increased sensitivity of ECT using this tracer in contrast to 131 I-labeled MAb fragments may be attributed to the fact that the physical properties of 111 In are much more suitable for the gamma cameras most commonly used (single detector, 3/8'' crystal); using 111 In-labelled MAb fragments, count rates sufficient for ECT can be obtained within a reasonable acquisition time. This allows to combine IS with the advantages of ECT regarding tumour localization and prevention of artefacts due to superposition of background. (orig.) [de

  13. Brain scintigraphy in patients with hydrocephalus

    International Nuclear Information System (INIS)

    Kadowaki, Hirotaka; Imanaga, Hirohisa; Kitamura, Koichi

    1975-01-01

    Brain scintigraphy is a simple, innocuous and valuable diagnostic method. Particulary in children, in order to minimize damage by examination, brain scintigraphy should be the first examination for patients, before other diagnostic methods such as cerebral angiography and pneumoencephalography. In the 3 years between Jan. 1970 and Dec. 1972, 235 children under the age of 15 years had brain scintigraphy with sup(99m)Tc pertechnetate at the Tokyo Women's Medical College Hospital. The authors especially attended to the findings of scintigrams in children with hydrocephalus. 29 children with non-neoplastic hydrocephalus were scanned with sup(99m)Tc pertechnetate: noncommunicating hydrocephalus; 9; hydroencephalodysplasia; 4; Chiari Arnold malformation; 1; cranium bifidum; 2; communicating hydrocephalis; 13. In noncommunicating hydrocephalus, the midline structure on the scintigram appeared thicker than the normal, because activity in the superior sagittal sinus was relatively high compared to the reduction of activity in the enlarged ventricles. In cases of very severe hydrocephalus, the basal ganglia was shown as a clear hot spot on the scintigram, because R. I. activity in the basal ganglia was relatively high compared to the reduction of R. I. activity in the enlarged ventricles. In cases of hydroencephalodysplasia, the midline structure on the scintigram shifted to the side opposite the dysplasia, as the result of pressure from a large CSF collection. In cases of cranium bifidum, the scintigram showed an elevation of the transverse sinus and the confluent sinus. (auth.)

  14. SFG investigation of adsorbed CO and NO on NiO(111) surface

    Energy Technology Data Exchange (ETDEWEB)

    Bandara, Athula; Dobashi, Shinsaku; Kubota, Jun; Onda, Ken; Wada, Akihide; Domen, Kazunari; Hirose, Chiaki [Tokyo Inst. of Tech., Yokohama (Japan). Research Lab. of Resources Utilization; Kano, S.S.

    1997-07-01

    Adsorption structures of CO and NO on the NiO(111) film grown on Ni(111) crystal have been investigated by sum frequency generation (SFG) spectroscopy and infrared reflection absorption spectroscopy (IRAS). The CO stretching band of adsorbed CO on NiO(111) was observed at 2144 cm{sup -1} on the SFG spectra for both p- and s-polarized visible light. However, adsorbed NO on NiO(111) was observed at 1805 cm{sup -1} on the SFG spectra only for the p-polarized visible light. The results suggest that the adsorbed CO molecule was tilted from the surface normal but the NO molecule was perpendicular to the surface. These orientations of CO and NO reflect the surface structure of NiO(111) which has (2 x 2)-reconstructed microfacets. Adsorption of CO on Ni(111) instead of NiO(111) was also examined by SFG and IRAS. Absorption bands due to linear and bridged CO were observed at 2076 and 1918 cm{sup -1}, respectively, by IRAS. On the other hand, the linear CO molecules on Ni(111) gave an SFG peak at 2076 cm{sup -1} only for the p-polarized visible light indicating the CO molecules are perpendicular to the surface, and bridged CO molecules did not give any SFG signal. The absence of the bridged CO signal is believed to be due to the smaller Raman tensor of bridged CO. (author)

  15. SFG investigation of adsorbed CO and NO on NiO(111) surface

    International Nuclear Information System (INIS)

    Bandara, Athula; Dobashi, Shinsaku; Kubota, Jun; Onda, Ken; Wada, Akihide; Domen, Kazunari; Hirose, Chiaki; Kano, S.S.

    1997-01-01

    Adsorption structures of CO and NO on the NiO(111) film grown on Ni(111) crystal have been investigated by sum frequency generation (SFG) spectroscopy and infrared reflection absorption spectroscopy (IRAS). The CO stretching band of adsorbed CO on NiO(111) was observed at 2144 cm -1 on the SFG spectra for both p- and s-polarized visible light. However, adsorbed NO on NiO(111) was observed at 1805 cm -1 on the SFG spectra only for the p-polarized visible light. The results suggest that the adsorbed CO molecule was tilted from the surface normal but the NO molecule was perpendicular to the surface. These orientations of CO and NO reflect the surface structure of NiO(111) which has (2 x 2)-reconstructed microfacets. Adsorption of CO on Ni(111) instead of NiO(111) was also examined by SFG and IRAS. Absorption bands due to linear and bridged CO were observed at 2076 and 1918 cm -1 , respectively, by IRAS. On the other hand, the linear CO molecules on Ni(111) gave an SFG peak at 2076 cm -1 only for the p-polarized visible light indicating the CO molecules are perpendicular to the surface, and bridged CO molecules did not give any SFG signal. The absence of the bridged CO signal is believed to be due to the smaller Raman tensor of bridged CO. (author)

  16. 23 CFR 635.111 - Tied bids.

    Science.gov (United States)

    2010-04-01

    ... MAINTENANCE Contract Procedures § 635.111 Tied bids. (a) The STD may tie or permit the tying of Federal-aid...-financed highway projects may be combined in one contract if the conditions of the projects are so similar...

  17. Understanding the self-assembly of TCNQ on Cu(111)

    DEFF Research Database (Denmark)

    Stradi, Daniele; Borca, Bogdana; Barja, Sara

    2016-01-01

    The structure of self-assembled monolayers of 7,7',8,8'-tetracyano-p-quinodimethane (TCNQ) adsorbed on Cu(111) has been studied using a combination of scanning tunnelling microscopy (STM) experiments and density functional theory (DFT) calculations. We show that the polymorphism of the self......-assembled molecular layer can be controlled by tuning of the experimental conditions under which the deposition is carried out. When the Cu(111) substrate is held above room temperature (T-Cu(111) = 350 K) during deposition, a structure is formed in which the two molecules in the unit cell are oriented one...... perpendicular to the other. Conversely, when the substrate is held at room temperature during deposition and slightly annealed afterwards, a more complex structure with five molecules per unit cell is formed. DFT calculations complement the experimental results by revealing that the building blocks of the two...

  18. The mechanical properties of T-111 at low to intermediate temperatures

    International Nuclear Information System (INIS)

    McCoy, H.E.; DiStefano, J.R.

    1997-01-01

    In the design of the 60-W Isotopic Heat Source (IHS), a tantalum alloy (T-111) strength member serves as the primary containment shell for the IHS during operation (He-gas internal environment and inert gas or vacuum external environment). An outer Hastelloy S clad is used to protect the T-111 from oxidation, and both the Hastelloy S clad and the T-111 strength member are sealed by automatic gas tungsten arc (GTA) welding. The expected life of the IHS is 5 years at about 650 C preceded by up to 5 years of storage at approximately 300 C. For this application, one important concern is failure of the T-111 strength member due to capsule pressurization arising from helium generation as a fuel decay product. To provide specific data on the mechanical behavior of base and solid metal T-111 under conditions appropriate to the IHS use conditions, a testing program was formulated and carried out. Three types of mechanical tests were conducted. Tensile properties were measured over the temperature range of 25 to 1100 C on T-111 base metal and samples with either longitudinal or transverse autogenous welds. Creep tests on base metal and samples with transverse welds were run to failure over the temperature range of 1100 to 850 C. Creep tests were also run on several transverse weld samples over the temperature range of 500 to 900 C at stresses where failure did not occur, and the creep rates were measured. Two prototypical capsules of the T-111 strength member were fabricated by EG and G Mound Applied Technologies (Mound Laboratories). To verify the mechanical properties design data developed above, these were tested to failure (leak) in a vacuum chamber with the inside of the capsule pressurized by either argon or helium

  19. Visualizing Mutation-Specific Differences in the Trafficking-Deficient Phenotype of Kv11.1 Proteins Linked to Long QT Syndrome Type 2.

    Science.gov (United States)

    Hall, Allison R; Anderson, Corey L; Smith, Jennifer L; Mirshahi, Tooraj; Elayi, Claude S; January, Craig T; Delisle, Brian P

    2018-01-01

    KCNH2 encodes the Kv11.1 α-subunit that underlies the rapidly activating delayed-rectifier K + current in the heart. Loss-of-function KCNH2 mutations cause long QT syndrome type 2 (LQT2), and most LQT2-linked missense mutations inhibit the trafficking of Kv11.1 channel protein to the cell surface membrane. Several trafficking-deficient LQT2 mutations (e.g., G601S) generate Kv11.1 proteins that are sequestered in a microtubule-dependent quality control (QC) compartment in the transitional endoplasmic reticulum (ER). We tested the hypothesis that the QC mechanisms that regulate LQT2-linked Kv11.1 protein trafficking are mutation-specific. Confocal imaging analyses of HEK293 cells stably expressing the trafficking-deficient LQT2 mutation F805C showed that, unlike G601S-Kv11.1 protein, F805C-Kv11.1 protein was concentrated in several transitional ER subcompartments. The microtubule depolymerizing drug nocodazole differentially affected G601S- and F805C-Kv11.1 protein immunostaining. Nocodazole caused G601S-Kv11.1 protein to distribute into peripheral reticular structures, and it increased the diffuse immunostaining of F805C-Kv11.1 protein around the transitional ER subcompartments. Proteasome inhibition also affected the immunostaining of G601S- and F805C-Kv11.1 protein differently. Incubating cells in MG132 minimally impacted G601S-Kv11.1 immunostaining, but it dramatically increased the diffuse immunostaining of F805C-Kv11.1 protein in the transitional ER. Similar results were seen after incubating cells in the proteasome inhibitor lactacystin. Differences in the cellular distribution of G601S-Kv11.1 and F805C-Kv11.1 protein persisted in transfected human inducible pluripotent stem cell derived cardiomyocytes. These are the first data to visually demonstrate mutation-specific differences in the trafficking-deficient LQT2 phenotype, and this study has identified a novel way to categorize trafficking-deficient LQT2 mutations based on differences in intracellular

  20. 45 CFR 46.111 - Criteria for IRB approval of research.

    Science.gov (United States)

    2010-10-01

    ... Section 46.111 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION PROTECTION OF HUMAN SUBJECTS Basic HHS Policy for Protection of Human Research Subjects § 46.111 Criteria for IRB... protect the rights and welfare of these subjects. ...