WorldWideScience

Sample records for improving blood compatibility

  1. Facile surface modification of silicone rubber with zwitterionic polymers for improving blood compatibility

    International Nuclear Information System (INIS)

    Liu, Pingsheng; Chen, Qiang; Yuan, Bo; Chen, Mengzhou; Wu, Shishan; Lin, Sicong; Shen, Jian

    2013-01-01

    A facile approach to modify silicone rubber (SR) membrane for improving the blood compatibility was investigated. The hydrophobic SR surface was firstly activated by air plasma, after which an initiator was immobilized on the activated surface for atom transfer radical polymerization (ATRP). Three zwitterionic polymers were then grafted from SR membrane via surface-initiated atom transfer radical polymerization (SI-ATRP). The surface composition, wettability, and morphology of the membranes before and after modification were characterized by X-ray photoelectron spectroscopy (XPS), static water contact angle (WCA) measurement, and atomic force microscopy (AFM). Results showed that zwitterionic polymers were successfully grafted from SR surfaces, which remarkably improved the wettability of the SR surface. The blood compatibility of the membranes was evaluated by protein adsorption and platelet adhesion tests in vitro. As observed, all the zwitterionic polymer modified surfaces have improved resistance to nonspecific protein adsorption and have excellent resistance to platelet adhesion, showing significantly improved blood compatibility. This work should inspire many creative uses of SR based materials for biomedical applications such as vessel, catheter, and microfluidics. Highlights: • Facile surface modification of silicone rubber with functional brushes • Modified SR surfaces have improved resistance to nonspecific protein adsorption. • Modified SR surfaces have excellent resistance to platelet adhesion. • Zwitteironic surface significant improvement in blood compatibility • Could inspire many creative uses of SR based materials for biomedical

  2. Facile surface modification of silicone rubber with zwitterionic polymers for improving blood compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Pingsheng [School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Chen, Qiang, E-mail: chem100@nju.edu.cn [School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); High Technology Research Institute of Nanjing University, Changzhou 213164 (China); Yuan, Bo; Chen, Mengzhou; Wu, Shishan; Lin, Sicong [School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Shen, Jian, E-mail: shenj1957@yahoo.com.cn [School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China)

    2013-10-15

    A facile approach to modify silicone rubber (SR) membrane for improving the blood compatibility was investigated. The hydrophobic SR surface was firstly activated by air plasma, after which an initiator was immobilized on the activated surface for atom transfer radical polymerization (ATRP). Three zwitterionic polymers were then grafted from SR membrane via surface-initiated atom transfer radical polymerization (SI-ATRP). The surface composition, wettability, and morphology of the membranes before and after modification were characterized by X-ray photoelectron spectroscopy (XPS), static water contact angle (WCA) measurement, and atomic force microscopy (AFM). Results showed that zwitterionic polymers were successfully grafted from SR surfaces, which remarkably improved the wettability of the SR surface. The blood compatibility of the membranes was evaluated by protein adsorption and platelet adhesion tests in vitro. As observed, all the zwitterionic polymer modified surfaces have improved resistance to nonspecific protein adsorption and have excellent resistance to platelet adhesion, showing significantly improved blood compatibility. This work should inspire many creative uses of SR based materials for biomedical applications such as vessel, catheter, and microfluidics. Highlights: • Facile surface modification of silicone rubber with functional brushes • Modified SR surfaces have improved resistance to nonspecific protein adsorption. • Modified SR surfaces have excellent resistance to platelet adhesion. • Zwitteironic surface significant improvement in blood compatibility • Could inspire many creative uses of SR based materials for biomedical.

  3. Mo doped DLC nanocomposite coatings with improved mechanical and blood compatibility properties

    Energy Technology Data Exchange (ETDEWEB)

    Tang, X.S. [School of Physics Science and Technology, Zhanjiang Normal University, Zhanjiang 524048 (China); Development Center for New Materials Engineering and Technology in Universities of Guangdong, Zhanjiang 524048 (China); Wang, H.J.; Feng, L. [School of Physics Science and Technology, Zhanjiang Normal University, Zhanjiang 524048 (China); Shao, L.X. [School of Physics Science and Technology, Zhanjiang Normal University, Zhanjiang 524048 (China); Development Center for New Materials Engineering and Technology in Universities of Guangdong, Zhanjiang 524048 (China); Zou, C.W., E-mail: qingyihaiyanas@163.com [School of Physics Science and Technology, Zhanjiang Normal University, Zhanjiang 524048 (China); Development Center for New Materials Engineering and Technology in Universities of Guangdong, Zhanjiang 524048 (China)

    2014-08-30

    Highlights: • Mo doped diamond like carbon coatings were deposited by magnetron sputtering. • The blood compatibility of Mo-DLC coatings was observed through platelet adhesion. • The amount of thrombus on the Mo-DLC is much less than that of pyrolytic carbon. - Abstract: Mo (molybdenum) doped diamond like carbon (Mo-DLC) coatings with improved mechanical and blood compatibility properties were deposited by closed field unbalanced magnetron sputtering. The undoped and Mo-doped DLC coatings were analyzed by various characterization techniques such as Raman spectra, Atomic force microscopy, and temperature-dependent frictional wear testing. The results showed that the Mo-DLC coating with low Mo concentration was a effective protective coating with reduced residual stress and increased cohesive strength, and kept good wear resistance at the ambient temperature of 500 °C. The blood compatibility of Mo-DLC coatings was investigated by platelet adhesion. The results showed that the amount of thrombus on the Mo-DLC nanocomposite coatings was much less than that of thrombus on pyrolytic carbon films. The Mo-DLC nanocomposite coatings would be a new kind of promising materials applied to artificial heart valve and endovascula stent.

  4. Mo doped DLC nanocomposite coatings with improved mechanical and blood compatibility properties

    International Nuclear Information System (INIS)

    Tang, X.S.; Wang, H.J.; Feng, L.; Shao, L.X.; Zou, C.W.

    2014-01-01

    Highlights: • Mo doped diamond like carbon coatings were deposited by magnetron sputtering. • The blood compatibility of Mo-DLC coatings was observed through platelet adhesion. • The amount of thrombus on the Mo-DLC is much less than that of pyrolytic carbon. - Abstract: Mo (molybdenum) doped diamond like carbon (Mo-DLC) coatings with improved mechanical and blood compatibility properties were deposited by closed field unbalanced magnetron sputtering. The undoped and Mo-doped DLC coatings were analyzed by various characterization techniques such as Raman spectra, Atomic force microscopy, and temperature-dependent frictional wear testing. The results showed that the Mo-DLC coating with low Mo concentration was a effective protective coating with reduced residual stress and increased cohesive strength, and kept good wear resistance at the ambient temperature of 500 °C. The blood compatibility of Mo-DLC coatings was investigated by platelet adhesion. The results showed that the amount of thrombus on the Mo-DLC nanocomposite coatings was much less than that of thrombus on pyrolytic carbon films. The Mo-DLC nanocomposite coatings would be a new kind of promising materials applied to artificial heart valve and endovascula stent

  5. Blood compatibility of gas plasma-treated diamond-like carbon surface-Effect of physicochemical properties of DLC surface on blood compatibility

    International Nuclear Information System (INIS)

    Mochizuki, Akira; Ogawa, Tatsuhisa; Okamoto, Keishi; Nakatani, Tatsuyuki; Nitta, Yuki

    2011-01-01

    From the knowledge that zwitterion-type polymers show good blood compatibility, the introduction of both cationic and anionic functional groups onto diamond-like carbon (DLC) surface is expected to improve blood compatibility. Thus, DLC films were treated with oxygen and ammonia gas plasmas. The surfaces were characterized in terms of chemical composition by XPS, contact angle, and zeta potential. XPS analysis showed the introductions of a carboxyl group by oxygen plasma treatment and nitrogen atoms by ammonia plasma treatment. The evaluation of blood compatibility for the DLC surfaces was carried out in terms of platelets and the coagulation system. Excellent improvement of platelet compatibility was observed by the treatment with the gas plasmas, regardless of the plasma species. As for the compatibility with the coagulation system, DLC surfaces with a high concentration of carboxyl groups (COOH) markedly activated the system via the intrinsic pathway. However, the surfaces treated with ammonia plasma did not activate the system even though they had high COOH concentration. Measurement of the zeta potential revealed that the ammonia plasma treatment raised the potential from a negative value to a positive one. Though the introduction of amino groups to the surface was not detected directly, the treatment of ammonia plasma changed the electrical state of the DLC surface having COOH group, causing a difference in blood compatibility among the DLCs obtained by various plasma conditions.

  6. Si+ and N+ ion implantation for improving blood compatibility of medical poly(methyl methacrylate)

    International Nuclear Information System (INIS)

    Li, D.J.; Cui, F.Z; Cui, F.Z.

    1998-01-01

    Si + and N + ion implantation into medical poly(methyl methacrylate) (PMMA) were performed at an energy of 80 keV with fluences ranging from 5x10 12 to 5x10 15 ions/cm 2 at room temperature to improve blood compatibility. The results of the blood contacting measurements in vitro showed that the anticoagulability and anticalcific behaviour on the surface morphology were enhanced after ion implantation. No appreciable change in the surface morphology was detected by scanning electron microscopy (SEM). X-ray photoelectron spectroscopy (XPS) analysis indicated that ion implantation broke some original chemical bonds on the surface to form some new Si- and N-containing groups. These results were considered responsible for the enhancement in the blood compatibility of PMMA. (author)

  7. Blood compatibility--a perspective.

    Science.gov (United States)

    Ratner, B D

    2000-01-01

    This perspective on blood- materials interactions is intended to introduce the set of papers stemming from the symposium, "Devices and Diagnostics in Contact with Blood: Issues in Blood Compatibility at the Close of the 20th Century," organized on August 4-6, 1999 at the University of Washington by the University of Washington Engineered Biomaterials (UWEB) Engineering Research Center. This article outlines some of the history of blood contacting materials, overviews the work that has originated at the University of Washington over the past 28 years, speculates on the origins of the controversies on blood compatibility and considers the issues that should be addressed in future studies.

  8. Improvement of blood compatibility of polyurethane elastomer by radiation graft copolymerization of 2-hydroxyethyl methacrylate in polymer matrix

    International Nuclear Information System (INIS)

    Li Ximing; Chen Wenming; Yuan Zhijian; Li Song; Lu Mei

    1988-01-01

    The γ-radiation induced grafting of 2-hydroxyethyl methacrylate (HEMA) onto polyurethane-elastomers (PUE) tube by preswelling technique to prepare biomedical materials with blood compatibility is studied. The graft yield can be controlled by regulating the preswelling time and temperature, or by change the irradiation dose and dose rate. After antithrombogenic test in vitro it has been confirmed that the blood compatibility of original polyurethane tube has been considerably improved by grafting

  9. Blood compatibility assessment of graft copolymer (NR-g-DMAA) tubes

    International Nuclear Information System (INIS)

    Razzak, M.T.; Otsuhata, Kazushige; Tabata, Yoneho; Ohashi, Fumio; Takeuchi, Atsuki

    1992-01-01

    Graft copolymer (NR-g-DMAA) tubes have been prepared using simultaneous radiation induced grafting of N,N-dimethyl-acrylamide, (DMAA) onto natural rubber (NR) tubes. The blood compatibility of the NR-g-DMAA tubes was assessed with three methods, namely in vitro test, ex vivo once through test and ex vivo loops test. In the case of the in vitro test, a simple whole blood contacting procedure has been employed. The ex vivo once through test involves the exposing of NR-g-DMAA tubes with once through flow of fresh canine blood and then it was inspected for any evidence of clot. In the case of ex vivo loops test, the NR-g-DMAA tube was implanted at external jugular vein of a mongrel canine and the blood flow in the NR-g-DMAA tube was detected with an ultrasonic flow meter. It was found that the blood compatibility of NR-g-DMAA tubes is improved significantly with the increasing degree of grafting. All the NR-g-DMAA tubes having a degree of grafting of about 30 wt% or more exhibit good blood compatibility. It was found that the blood compatibility of the NR-g-DMAA tube is better than that of a medical grade silicon rubber (SiR) tube. (Author)

  10. In vitro Blood Compatibility of Polyethylene Terephthalate with Covalently Bounded Hirudin on Surface

    Institute of Scientific and Technical Information of China (English)

    LI Fang; WANG Jin; HUANG San

    2011-01-01

    Polyethylene terephthalate (PET,Dacron) was modified by surface immobilization of hirudin with glutaraldehyde(GA) as coupling reagent to improve the blood compatibility.Hirudin-immobilizcd PETs were characterized by X-ray photoelectron spectroscopy (XPS) and contact angle measurements.The blood compatibility of the PETs was evaluated by platelet adhesion evaluation and fibrinogen conformational change measurements in vitro.The results showed the decrease of platelet adhesion and activation on hirudinimmobilized PET with increasing of glutaraldehyde concentration.Fibrinogen experiment showed that fibrinogen adherence and conformational changes of PET-HRD were less than those of untreated PET,which made the materials difficult to form thrombus.The proper reason of blood compatibility improvement was low interface tension between hirudin-immobilized PETs and blood,as well as blood proteins,and low ratio of dispersive/polar component of the surface energy(γsd/γsp) and high hydrophilicity.

  11. Blood compatibility of AAc, HEMA, and PEGMA-grafted cellulose film

    International Nuclear Information System (INIS)

    Nho, Young Chang.; Kwon, Oh Hyun

    2003-01-01

    To improve surface blood compatibility on cellulose film for hemodialysis, acrylic acid, 2-hydroxyethyl methacrylate and three kinds of polyethylene glycol methacrylates were grafted onto the cellulose film surface by radiation grafting technique. Heparin was introduced onto the grafted cellulose film surfaces. The grafting and heparinization were confirmed by Fourier transform infrared spectroscopy in the attenuated total reflectance mode and electron spectroscopy for chemical analysis. The blood compatibility of the modified cellulose film was examined by the determination of platelet adhesion and thrombus formation

  12. In vitro blood compatibility of poly (hydroxybutyrate-co-hydroxyhexanoate) and the influence of surface modification by alkali treatment

    International Nuclear Information System (INIS)

    Shen Feng; Zhang Erlin; Wei Zunjie

    2010-01-01

    In vitro blood compatibility of poly (hydroxybutyrate-co-hydroxyhexanoate) (PHBHHx) was evaluated in comparison with poly (L-lactic acid) (PLLA) by a haemolysis assay, in vitro platelet adhesion test and coagulation measurements including plasma recalcification time (PRT), plasma prothrombin time (PT) and kinetic clotting time. The results showed that PHBHHx exhibited better blood compatibility than PLLA. Furthermore, PHBHHx film was modified by NaOH treatment to improve the surface hydrophilic property and the influence of the surface modification on the blood compatibility was investigated. Surface properties including hydrophilic property, surface appearance and functional groups were characterized by water contact angle measurement, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The results showed that the hydrophilic property of PHBHHx film was obviously improved by the NaOH treatment. It was also shown that the NaOH treatment could significantly enhance the blood compatibility of PHBHHx by prolonging PRT, PT, and kinetic clotting time and decreasing platelet activation. It is thought that the improvement in the hydrophilic property mainly contributes to the enhancement of blood compatibility.

  13. Development of materials with blood compatibility by radiation processing

    International Nuclear Information System (INIS)

    Roesinger, S.; Fischer, J.P.; Fuhge, P.

    1982-01-01

    Biomedical applications, for example for rendering plastic materials blood compatible, have become a very important problem in recent years. Surface-grafted materials for blood compatibility have attracted attention for intra- and extracorporal applications. Numerous aspects of grafting monomers on to polymer surfaces by different grafting methods have been given. A large amount of work has been done during the last ten years, but nobody has prepared materials with properties that are desirable for long-term medical application in the human body, for example as replacements for small arteries or veins. The evaluation of blood compatibility of different plastic materials, and the search for correlations between blood compatibility and physical properties of the plastic materials surfaces, are well-known problems in the biomedical applications of polymers. This paper briefly reviews an approach to help solving these problems. (author)

  14. Nano-structure TiO2 film coating on 316L stainless steel via sol-gel technique for blood compatibility improvement

    Directory of Open Access Journals (Sweden)

    Mohammadreza Foruzanmehr

    2014-04-01

    Full Text Available   Objective(s: Titanium oxides are known to be appropriate hemocompatible materials which are suggested as coatings for blood-contacting devices. Little is known about the influence of nanometric crystal structure, layer thickness, and semiconducting characteristics of TiO2 on blood hemostasis.   Materials and Methods: Having used sol-gel dip coating method in this study, TiO2 thin films were deposited on nano-scale electro-polished stainless steel 316L with 1 to 5 nano-sized layers. Surface morphology and structure of the film were studied with X-ray diffraction and atomic force microscopy. Blood compatibility was also determined by measuring the platelet activation (CD62P expression, platelet adhesion (Scanning Electron Microscopy, and the blood clotting time on these samples. Results: The films were compact and smooth and existed mainly in the form of anatase. By increasing the number of TiO2 thin layer, clotting time greatly extended, and the population of activated platelet and P-selectine expression changed according to the surface characteristics of each layer. Conclusion: The findings revealed that stainless steel 316L coated with nano-structured TiO2 layer improved blood compatibility, in terms of both blood platelet activity and coagulation cascade, which can decrease the thrombogenicity of blood contacting devices which were made from stainless steel.

  15. Blood Compatibility of ZrO2 Particle Reinforced PEEK Coatings on Ti6Al4V Substrates

    Directory of Open Access Journals (Sweden)

    Jian Song

    2017-11-01

    Full Text Available Titanium (Ti and its alloys are widely used in biomedical devices. As biomaterials, the blood compatibility of Ti and its alloys is important and needs to be further improved to provide better functionality. In this work, we studied the suitability of zirconia (ZrO2 particle reinforced poly-ether-ether-ketone (PEEK coatings on Ti6Al4V substrates for blood-contacting implants. The wettability, surface roughness and elastic modulus of the coatings were examined. Blood compatibility tests were conducted by erythrocytes observation, hemolysis assay and clotting time of recalcified human plasma, to find out correlations between the microstructure of the ZrO2-filled PEEK composite coatings and their blood compatibilities. The results suggested that adding ZrO2 nanoparticles increased the surface roughness and improved the wettability and Derjaguin-Muller-Toporov (DMT elastic modulus of PEEK coating. The PEEK composite matrix coated Ti6Al4V specimens did not cause any aggregation of erythrocytes, showing morphological normal shapes. The hemolysis rate (HR values of the tested specimens were much less than 5% according to ISO 10993-4 standard. The values of plasma recalcification time (PRT of the tested specimens varied with the increasing amount of ZrO2 nanoparticles. Based on the results obtained, 10 wt % ZrO2 particle reinforced PEEK coating has demonstrated an optimum blood compatibility, and can be considered as a candidate to improve the performance of existing PEEK based coatings on titanium substrates.

  16. Clinical evaluation of a 51Cr-labeled red blood cell survival test for in vivo blood compatibility testing

    International Nuclear Information System (INIS)

    Pineda, A.A.; Dharkar, D.D.; Wahner, H.W.

    1984-01-01

    Modified red blood cell survival studies with use of 51Cr were performed in three groups of subjects. Group 1 consisted of normal subjects who were given labeled autologous blood, group 2 were subjects in need of blood transfusions and given labeled ABO and Rh crossmatch-compatible blood, and group 3 were patients in need of blood transfusion but in whom problems arose in finding compatible blood. The results of the studies suggest that for patients with blood compatibility problems, normal red blood cell survival values at 1 hour do not exclude the possibility of severe hemolysis 24 hours later. Thus, if a 1-hour test result is normal, the procedure should be extended routinely to 24 hours. Moreover, the test can be used to evaluate the clinical importance of antibodies. We showed that anti-Yka and anti-Lan were clinically significant, but high-titer, low-avidity antibodies, anti-Kna, anti-I, and anti-HI were clinically insignificant in the cases studied. This finding emphasizes the importance of an in vivo test for the final compatibility evaluation in complicated blood replacement problems

  17. Development of bio/blood compatible polypropylene through low pressure nitrogen plasma surface modification

    International Nuclear Information System (INIS)

    Gomathi, N.; Rajasekar, R.; Babu, R. Rajesh; Mishra, Debasish; Neogi, S.

    2012-01-01

    Surface modification of polypropylene by nitrogen containing plasma was performed in this work in order to improve the wettability which resulted in enhanced biocompatibility and blood compatibility. Various nitrogen containing functional groups as well as oxygen containing functional groups were found to be incorporated to the polymer surface during plasma treatment and post plasma reaction respectively. Wettability of the polymers was evaluated by static contact angle measurement to show the improvement in hydrophilicity of plasma treated polypropylene. Cross linking and surface modification were reported to be dominating in the case of nitrogen plasma treatment compared to degradation. The effect of various process variables namely power, pressure, flow rate and treatment time on surface energy and weight loss was studied at various levels according to the central composite design of response surface methodology (RSM). Except pressure the other variables resulted in increased weight loss due to etching whereas with increasing pressure weight loss was found to increase and then decrease. The effect of process variables on surface morphology of polymers was evaluated by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). Well spread fibroblast cells on nitrogen plasma treated polypropylene due to the presence of CO, NH 2+ and NH + was observed. Reduced platelet adhesion and increased partial thromboplastin time evidenced the increased blood compatibility. - Highlights: ► Improved biocompatibility and blood compatibility of polypropylene. ► Nitrogen plasma surface modification. ► Maintaining a balance between polar group incorporation and weight loss due to etching. ► Optimization of process conditions by response surface methodology.

  18. Blood Compatibility of Sulfonated Cladophora Nanocellulose Beads

    Directory of Open Access Journals (Sweden)

    Igor Rocha

    2018-03-01

    Full Text Available Sulfonated cellulose beads were prepared by oxidation of Cladophora nanocellulose to 2,3-dialdehyde cellulose followed by sulfonation using bisulfite. The physicochemical properties of the sulfonated beads, i.e., high surface area, high degree of oxidation, spherical shape, and the possibility of tailoring the porosity, make them interesting candidates for the development of immunosorbent platforms, including their application in extracorporeal blood treatments. A desired property for materials used in such applications is blood compatibility; therefore in the present work, we investigate the hemocompatibility of the sulfonated cellulose beads using an in vitro whole blood model. Complement system activation (C3a and sC5b-9 levels, coagulation activation (thrombin-antithrombin (TAT levels and hemolysis were evaluated after whole blood contact with the sulfonated beads and the results were compared with the values obtained with the unmodified Cladophora nanocellulose. Results showed that neither of the cellulosic materials presented hemolytic activity. A marked decrease in TAT levels was observed after blood contact with the sulfonated beads, compared with Cladophora nanocellulose. However, the chemical modification did not promote an improvement in Cladophora nanocellulose hemocompatibility in terms of complement system activation. Even though the sulfonated beads presented a significant reduction in pro-coagulant activity compared with the unmodified material, further modification strategies need to be investigated to control the complement activation by the cellulosic materials.

  19. Blood Compatibility of Sulfonated Cladophora Nanocellulose Beads.

    Science.gov (United States)

    Rocha, Igor; Lindh, Jonas; Hong, Jaan; Strømme, Maria; Mihranyan, Albert; Ferraz, Natalia

    2018-03-07

    Sulfonated cellulose beads were prepared by oxidation of Cladophora nanocellulose to 2,3-dialdehyde cellulose followed by sulfonation using bisulfite. The physicochemical properties of the sulfonated beads, i.e., high surface area, high degree of oxidation, spherical shape, and the possibility of tailoring the porosity, make them interesting candidates for the development of immunosorbent platforms, including their application in extracorporeal blood treatments. A desired property for materials used in such applications is blood compatibility; therefore in the present work, we investigate the hemocompatibility of the sulfonated cellulose beads using an in vitro whole blood model. Complement system activation (C3a and sC5b-9 levels), coagulation activation (thrombin-antithrombin (TAT) levels) and hemolysis were evaluated after whole blood contact with the sulfonated beads and the results were compared with the values obtained with the unmodified Cladophora nanocellulose. Results showed that neither of the cellulosic materials presented hemolytic activity. A marked decrease in TAT levels was observed after blood contact with the sulfonated beads, compared with Cladophora nanocellulose. However, the chemical modification did not promote an improvement in Cladophora nanocellulose hemocompatibility in terms of complement system activation. Even though the sulfonated beads presented a significant reduction in pro-coagulant activity compared with the unmodified material, further modification strategies need to be investigated to control the complement activation by the cellulosic materials.

  20. Preliminary study of blood compatibility of PTFE copolymerized with DMAA through gamma rays compared to PET and aflon films

    International Nuclear Information System (INIS)

    Queiroz, A.A.A. de; Higa, O.Z.

    1990-01-01

    The new method developed by Imai and Nosa was used for the evaluation of blood compatibility of poly(tetrafluoroethylene) (PTFE) grafted films with N,N - dimethylacrylamide (DMAA). The amount of the formed thrombus was measured gravimetrically at an appropriate interval of time after calcium chloride being added to the ACD blood in contact to the tested material. It was concluded that the method of modifying the polymeric surface of PTFE by grafting the hydrophilic monomer DMAA improved its blood compatibility. (author)

  1. Enhancement of the blood compatibility of dialyzer membranes by the physical adsorption of human thrombomodulin (ART-123).

    Science.gov (United States)

    Omichi, Masaaki; Matsusaki, Michiya; Kato, Shinya; Maruyama, Ikuro; Akashi, Mitsuru

    2010-11-01

    ART-123 is a recombinant soluble human thrombomodulin (hTM) with excellent anticoagulant activity. We focused on improving the blood compatibility of the polysulfone-polyvinylpyrrolidone dialyzer surface by the physical adsorption of ART-123 onto the surface. The blood compatibility of the dialyzer with the hTM adsorbed membrane was evaluated by measuring the differential pressure between the arterial and the venous pressures and by blood parameters during blood circulation. The hTM adsorbed dialyzer membrane inhibited blood clot formation without heparin administration due to the anticoagulant activity of hTM for over 4 h. The physically adsorbed hTM was stable during blood circulation, and it did not affect activated clotting time, which is significant drawback of heparin administration, and blood cell counts of RBC, WBC, or platelets. The physical adsorption of hTM onto the dialyzer membrane will be a simple and safe method to prevent blood coagulation during dialysis instead of heparin administration. © 2010 Wiley Periodicals, Inc.

  2. Micro-Arc Oxidation Enhances the Blood Compatibility of Ultrafine-Grained Pure Titanium

    Directory of Open Access Journals (Sweden)

    Lin Xu

    2017-12-01

    Full Text Available Ultrafine-grained pure titanium prepared by equal-channel angular pressing has favorable mechanical performance and does not contain alloy elements that are toxic to the human body. It has potential clinical value in applications such as cardiac valve prostheses, vascular stents, and hip prostheses. To overcome the material’s inherent thrombogenicity, surface-coating modification is a crucial pathway to enhancing blood compatibility. An electrolyte solution of sodium silicate + sodium polyphosphate + calcium acetate and the micro-arc oxidation (MAO technique were employed for in situ oxidation of an ultrafine-grained pure titanium surface. A porous coating with anatase- and rutile-phase TiO2 was generated and wettability and blood compatibility were examined. The results showed that, in comparison with ultrafine-grained pure titanium substrate, the MAO coating had a rougher surface, smaller contact angles for distilled water and higher surface energy. MAO modification effectively reduced the hemolysis rate; extended the dynamic coagulation time, prothrombin time (PT, and activated partial thromboplastin time (APTT; reduced the amount of platelet adhesion and the degree of deformation; and enhanced blood compatibility. In particular, the sample with an oxidation time of 9 min possessed the highest surface energy, largest PT and APTT values, smallest hemolysis rate, less platelet adhesion, a lesser degree of deformation, and more favorable blood compatibility. The MAO method can significantly enhance the blood compatibility of ultrafine-grained pure titanium, increasing its potential for practical applications.

  3. Reverse indentation size effects in gamma irradiated blood compatible blend films of chitosan-poly (vinyl alcohol) for possible medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Bisen, D.S. [Department of Post Graduate Studies and Research in Physics, Rani Durgawati University, Jabalpur, M.P. 482002 (India); Bhatt, Rinkesh [Department of Physics, Global Engineering College, Jabalpur, M.P. 482001 (India); Bajpai, A.K., E-mail: akbmrl@yahoo.co.in [Department of Chemistry, Bose Memorial Research Lab., Govt. Auto. Model Science College, Jabalpur 482002, M.P. (India); Bajpai, R. [Department of Post Graduate Studies and Research in Physics, Rani Durgawati University, Jabalpur, M.P. 482002 (India); Katare, R. [Department of Physics, Government Model Science College, Jabalpur, M.P. 482001 (India)

    2017-02-01

    In the present work binary blends of polyvinyl alcohol (PVA) and chitosan (CS) were prepared by solution cast method and characterized by analytical methods like FTIR, XRD and SEM for seeking structural and morphological information. The blends were exposed to gamma radiation and evaluated for their improved mechanical strength. It was found that the tensile strength and microhardness increased after irradiation of CS-PVA films. Plastic effect due to absorption of water molecules and scissoring effect due to gamma irradiation were found to decrease the softness or increase the microhardness of the blends. Improved mechanical properties were attributed to intermolecular and intramolecular hydrogen bonds and adhesive nature of the blends also. The blends were also investigated for water intake behavior and in vitro blood compatibility property on the basis of certain in vitro tests like protein adsorption, haemolysis and blood clot formation on the un-irradiated and irradiated blend samples. The increased % swelling with time could be assigned to the fact that increasing water content facilitates the phase separation process within the blend which results in advancement in interstitial nano-void spaces which are occupied by water molecules. The blood compatibility results showed that when the amount of CS was varied from 0.5% to 2%, the amount of blood clot and percent haemolysis decreased while the protein adsorption increased with increasing CS content of the blend films. - Highlights: • Fully crosslinked blends of PVA and chitosan have been prepared. • Blends were irradiated with gamma radiations to enhance blood compatibility. • Mechanical properties were evaluated and effect of irradiation was examined. • The blood compatibility of blends was also determined.

  4. Reverse indentation size effects in gamma irradiated blood compatible blend films of chitosan-poly (vinyl alcohol) for possible medical applications

    International Nuclear Information System (INIS)

    Bisen, D.S.; Bhatt, Rinkesh; Bajpai, A.K.; Bajpai, R.; Katare, R.

    2017-01-01

    In the present work binary blends of polyvinyl alcohol (PVA) and chitosan (CS) were prepared by solution cast method and characterized by analytical methods like FTIR, XRD and SEM for seeking structural and morphological information. The blends were exposed to gamma radiation and evaluated for their improved mechanical strength. It was found that the tensile strength and microhardness increased after irradiation of CS-PVA films. Plastic effect due to absorption of water molecules and scissoring effect due to gamma irradiation were found to decrease the softness or increase the microhardness of the blends. Improved mechanical properties were attributed to intermolecular and intramolecular hydrogen bonds and adhesive nature of the blends also. The blends were also investigated for water intake behavior and in vitro blood compatibility property on the basis of certain in vitro tests like protein adsorption, haemolysis and blood clot formation on the un-irradiated and irradiated blend samples. The increased % swelling with time could be assigned to the fact that increasing water content facilitates the phase separation process within the blend which results in advancement in interstitial nano-void spaces which are occupied by water molecules. The blood compatibility results showed that when the amount of CS was varied from 0.5% to 2%, the amount of blood clot and percent haemolysis decreased while the protein adsorption increased with increasing CS content of the blend films. - Highlights: • Fully crosslinked blends of PVA and chitosan have been prepared. • Blends were irradiated with gamma radiations to enhance blood compatibility. • Mechanical properties were evaluated and effect of irradiation was examined. • The blood compatibility of blends was also determined.

  5. Surface Modification of Biomaterials: A Quest for Blood Compatibility

    OpenAIRE

    de Mel, Achala; Cousins, Brian G.; Seifalian, Alexander M.

    2012-01-01

    Cardiovascular implants must resist thrombosis and intimal hyperplasia to maintain patency. These implants when in contact with blood face a challenge to oppose the natural coagulation process that becomes activated. Surface protein adsorption and their relevant 3D confirmation greatly determine the degree of blood compatibility. A great deal of research efforts are attributed towards realising such a surface, which comprise of a range of methods on surface modification. Surface modification ...

  6. Deposition of boron doped DLC films on TiNb and characterization of their mechanical properties and blood compatibility.

    Science.gov (United States)

    Liza, Shahira; Hieda, Junko; Akasaka, Hiroki; Ohtake, Naoto; Tsutsumi, Yusuke; Nagai, Akiko; Hanawa, Takao

    2017-01-01

    Diamond-like carbon (DLC) material is used in blood contacting devices as the surface coating material because of the antithrombogenicity behavior which helps to inhibit platelet adhesion and activation. In this study, DLC films were doped with boron during pulsed plasma chemical vapor deposition (CVD) to improve the blood compatibility. The ratio of boron to carbon (B/C) was varied from 0 to 0.4 in the film by adjusting the flow rate of trimethylboron and acetylene. Tribological tests indicated that boron doping with a low B/C ratio of 0.03 is beneficial for reducing friction (μ = 0.1), lowering hardness and slightly increasing wear rate compared to undoped DLC films. The B/C ratio in the film of 0.03 and 0.4 exhibited highly hydrophilic surface owing to their high wettability and high surface energy. An in vitro platelet adhesion experiment was conducted to compare the blood compatibility of TiNb substrates before and after coating with undoped and boron doped DLC. Films with highly hydrophilic surface enhanced the blood compatibility of TiNb, and the best results were obtained for DLC with the B/C ratio of 0.03. Boron doped DLC films are promising surface coatings for blood contacting devices.

  7. The radiation destruction of blood compatible blockcopolymers

    International Nuclear Information System (INIS)

    Gorelik, B.A.; Raygorodsky, I.M.; Dubinskaya, O.V.; Goldberg, E.Sh.; Listvoyb, G.I.

    1991-01-01

    Among the blood compatible polymers such blockcopolymers as polyurethanes and polycarbonatesiloxanes the main problem of the production is the method of sterilization. It is considered that the radiation sterilization promising for articles like catheters made from these polymers. There are some data in the literature about radiation stability of polycarbonates and polysiloxane, but the influence of ionizing irradiation on polycarbonatesiloxane was not studied until now. The irradiation was carried out by γ-cell RHM-γ-20 in air. (author) 4 refs.; 5 figs

  8. Synthesis of novel liquid crystal compounds and their blood compatibility as anticoagulative materials

    International Nuclear Information System (INIS)

    Tu Mei; Cha Zhenhang; Feng Bohua; Zhou Changren

    2006-01-01

    The objective of this study was to synthesize new types of cholesteric liquid crystal compounds and study the anticoagulative properties of their composite membranes. Three kinds of cholesteric liquid crystal compounds were synthesized and characterized by infrared spectroscopy, differential scanning calorimetry and optical polarizing microscope. The polysiloxane, as a substrate, was blended with three liquid crystal compounds and was then used as membranes. The anticoagulative property of different polysiloxane liquid crystal composite membranes was identified by the blood compatibility tests. Three cholesteryl liquid crystals synthesized in this work contained hydrophilic soft chains and presented iridescent texture owned by cholesteric liquid crystals in the range of their liquid crystal state temperature, but only cholesteryl acryloyl oxytetraethylene glycol carbonate was in the liquid crystal state at body temperature. When liquid crystals were blended with polysiloxane to form polysiloxane/liquid crystal composite membranes, the haemocompatibility of these membranes could be improved to some extent. The blood compatibility of composite membranes whose hydrophilic property was the best was more excellent than that of other composite membranes, fewer platelets adhered and spread, and showed little distortion on the surface of materials

  9. Polyurethane Organosilicate Nanocomposites as Blood Compatible Coatings

    Directory of Open Access Journals (Sweden)

    Johnson H. Y. Chung

    2012-02-01

    Full Text Available Polymer clay nanocomposites (NCs show remarkable potential in the field of drug delivery due to their enhanced barrier properties. It is hypothesised that well dispersed clay particles within the polymer matrix create a tortuous pathway for diffusing therapeutic molecules, thereby resulting in more sustained release of the drug. As coatings for medical devices, these materials can simultaneously modulate drug release and improve the mechanical performance of an existing polymer system without introducing additional materials with new chemistries that can lead to regulatory concerns. In this study, polyurethane organosilicate nanocomposites (PUNCs coated onto stainless steel wires were evaluated for their feasibility as blood compatible coatings and as drug delivery systems. Heparin was selected as the model drug to examine the impact of silicate loading and modifier chain length in modulating release. Findings revealed that better dispersion was achieved from samples with lower clay loadings and longer alkyl chains. The blood compatibility of PUNCs as assessed by thrombin generation assays showed that the addition of silicate particles did not significantly decrease the thrombin generation lag time (TGT, p = 0.659 or the peak thrombin (p = 0.999 of polyurethane (PU. PUNC coatings fabricated in this research were not cytotoxic as examined by the cell growth inhibition assay and were uniformly intact, but had slightly higher growth inhibition compared to PU possibly due to the presence of organic modifiers (OM. The addition of heparin into PUNCs prolonged the TGT, indicating that heparin was still active after the coating process. Cumulative heparin release profiles showed that the majority of heparin released was from loosely attached residues on the surface of coils. The addition of heparin further prolonged the TGT as compared to coatings without added heparin, but a slight decrease in heparin activity was observed in the NCs

  10. Comparison of a commercial blood cross-matching kit to the standard laboratory method for establishing blood transfusion compatibility in dogs.

    Science.gov (United States)

    Guzman, Leo Roa; Streeter, Elizabeth; Malandra, Allison

    2016-01-01

    To evaluate the accuracy of a commercial blood transfusion cross-match kit when compared to the standard laboratory method for establishing blood transfusion compatibility. A prospective observational in intro study performed from July 2009 to July 2013. Private referral veterinary center. Ten healthy dogs, 11 anemic dogs, and 24 previously transfused dogs. None. Forty-five dogs were enrolled in a prospective study in order to compare the standard blood transfusion cross-match technique to a commercial blood transfusion cross-matching kit. These dogs were divided into 3 different groups that included 10 healthy dogs (control group), 11 anemic dogs in need of a blood transfusion, and 24 sick dogs that were previously transfused. Thirty-five dogs diagnosed with anemia secondary to multiple disease processes were cross-matched using both techniques. All dogs cross-matched via the kit had a compatible major and minor result, whereas 16 dogs out of 45 (35%) had an incompatible cross-match result when the standard laboratory technique was performed. The average time to perform the commercial kit was 15 minutes and this was 3 times shorter than the manual cross-match laboratory technique that averaged 45-50 minutes to complete. While the gel-based cross-match kit is quicker and less technically demanding than standard laboratory cross-match procedures, microagglutination and low-grade hemolysis are difficult to identify by using the gel-based kits. This could result in transfusion reactions if the gel-based kits are used as the sole determinant of blood compatibility prior to transfusion. Based on our results, the standard manual cross-match technique remains the gold standard test to determine blood transfusion compatibility. © Veterinary Emergency and Critical Care Society 2016.

  11. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus

    International Nuclear Information System (INIS)

    Chen Guochong; Liu Wen; Liu Qingfang

    2011-01-01

    The blood compatibility of the radiation sterilized disposable burette transfusion apparatus was investigated to provide evidence for the safety of radiation sterilized medical devices. The initial bacteria burden of the disposable burette transfusion apparatus was examined according to the ISO11737 standard, and the whole blood clotting time, prothrombin time, partial thromboplastin time and hemolysis rate of the samples were determined. There was no significant difference between the radiation sterilized samples and negative controls on WBCT, PT and PTT (p>0.05). Haemolysis test showed that the haemolysis rate of the sample sterilized by irradiation was 1.38%, which was coincidence with the criteria of the medical devices. After sterilization by irradiation, disposable burette transfusion apparatus show good blood compatibility, which could be considered that radiation sterilization is a biologically safe method for the medical apparatus. (authors)

  12. Tailoring of TiO2 films by H2SO4 treatment and UV irradiation to improve anticoagulant ability and endothelial cell compatibility.

    Science.gov (United States)

    Liao, Yuzhen; Li, Linhua; Chen, Jiang; Yang, Ping; Zhao, Ansha; Sun, Hong; Huang, Nan

    2017-07-01

    Surfaces with dual functions that simultaneously exhibit good anticoagulant ability and endothelial cell (EC) compatibility are desirable for blood contact materials. However, these dual functions have rarely been achieved by inorganic materials. In this study, titanium dioxide (TiO 2 ) films were treated by sulphuric acid (H 2 SO 4 ) and ultraviolet (UV) irradiation successively (TiO 2 H 2 SO 4 -UV), resulting in good anticoagulant ability and EC compatibility simultaneously. We found that UV irradiation improved the anticoagulant ability of TiO 2 films significantly while enhancing EC compatibility, though not significantly. The enhanced anticoagulant ability could be related to the oxidation of surface-adsorbed hydrocarbons and increased hydrophilicity. The H 2 SO 4 treatment improved the anticoagulant ability of TiO 2 films slightly, while UV irradiation improved the anticoagulant ability strongly. The enhanced EC compatibility could be related to the increased surface roughness and positive charges on the surface of the TiO 2 films. Furthermore, the time-dependent degradation of the enhanced EC compatibility and anticoagulant ability of TiO 2 H 2 SO 4 -UV was observed. In summary, TiO 2 H 2 SO 4 -UV expressed both excellent anticoagulant ability and good EC compatibility at the same time, which could be desirable for blood contact materials. However, the compatibility of TiO 2 H 2 SO 4 -UV with smooth muscle cells (SMCs) and macrophages was also improved. More effort is still needed to selectively improve EC compatibility on TiO 2 films for better re-endothelialization. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Ion implantation and bio-compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshiaki; Kusakabe, Masahiro [Sony Corp., Tokyo (Japan). Corporate Research Labs.; Iwaki, Masaya

    1992-07-01

    Surface modification of polymers by ion implantation has been carried out to control surface properties such as conductivity, wettability, blood and tissue compatibility. Ion implantation into silicone rubber, polystyrene and segmented polyurethane was performed at 150 keV with doses ranging from 1 x 10[sup 15] to 3 x 10[sup 17] ions/cm[sup 2] to improve bio-compatibility. The platelet accumulation on ion implanted silicone rubber decreased and non-thrombogenicity of ion implanted specimens were improved. The ion implanted polystyrene and segmented polyurethane have been found to exhibit remarkably higher adhesion and spreading of endothelial cells compared to the non-implanted case. It is concluded that ion implantation into polymers is effective in controlling their bio-compatibility. (author).

  14. Blood compatibility of magnesium and its alloys.

    Science.gov (United States)

    Feyerabend, Frank; Wendel, Hans-Peter; Mihailova, Boriana; Heidrich, Stefanie; Agha, Nezha Ahmad; Bismayer, Ulrich; Willumeit-Römer, Regine

    2015-10-01

    Blood compatibility analysis in the field of biomaterials is a highly controversial topic. Especially for degradable materials like magnesium and its alloys no established test methods are available. The purpose of this study was to apply advanced test methodology for the analysis of degrading materials to get a mechanistic insight into the corrosion process in contact with human blood and plasma. Pure magnesium and two magnesium alloys were analysed in a modified Chandler-Loop setup. Standard clinical parameters were determined, and a thorough analysis of the resulting implant surface chemistry was performed. The contact of the materials to blood evoked an accelerated inflammatory and cell-induced osteoconductive reaction. Corrosion products formed indicate a more realistic, in vivo like situation. The active regulation of corrosion mechanisms of magnesium alloys by different cell types should be more in the focus of research to bridge the gap between in vitro and in vivo observations and to understand the mechanism of action. This in turn could lead to a better acceptance of these materials for implant applications. The presented study deals with the first mechanistic insights during whole human blood contact and its influence on a degrading magnesium-based biomaterial. The combination of clinical parameters and corrosion layer analysis has been performed for the first time. It could be of interest due to the intended use of magnesium-based stents and for orthopaedic applications for clinical applications. An interest for the readers of Acta Biomaterialia may be given, as one of the first clinically approved magnesium-based devices is a wound-closure device, which is in direct contact with blood. Moreover, for orthopaedic applications also blood contact is of high interest. Although this is not the focus of the manuscript, it could help to rise awareness for potential future applications. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All

  15. Structure and blood compatibility of highly oriented PLA/MWNTs composites produced by solid hot drawing.

    Science.gov (United States)

    Li, Zhengqiu; Zhao, Xiaowen; Ye, Lin; Coates, Phil; Caton-Rose, Fin; Martyn, Michasel

    2014-03-01

    Highly oriented poly(lactic acid) (PLA)/multi-walled carbon nanotubes (MWNTs) composites were fabricated through solid hot drawing technology in an effort to improve the mechanical properties and blood biocompatibility of PLA as blood-contacting medical devices. It was found that proper MWNTs content and drawing orientation can improve the tensile strength and modulus of PLA dramatically. With the increase in draw ratio, the cold crystallization peak became smaller, and the glass transition and the melting peak of PLA moved to high temperature, while the crystallinity increased, and the grain size decreased, indicating the stress-induced crystallization of PLA during drawing. MWNTs showed a nucleation effect on PLA, leading to the rise in the melting temperature, increase in crystallinity and reduction of spherulite size for the composites. Moreover, the intensity of (002) diffraction of MWNTs increased with draw ratio, indicating that MWNTs were preferentially aligned and oriented during drawing. Microstructure observation demonstrated that PLA matrix had an ordered fibrillar bundle structure, and MWNTs in the composite tended to align parallel to the drawing direction. In addition, the dispersion of MWNTs in PLA was also improved by orientation. Introduction of MWNTs and drawing orientation could significantly enhance the blood compatibility of PLA by prolonging kinetic clotting time, reducing hemolysis ratio and platelet activation.

  16. Surface Modification of Biomaterials: A Quest for Blood Compatibility

    Directory of Open Access Journals (Sweden)

    Achala de Mel

    2012-01-01

    Full Text Available Cardiovascular implants must resist thrombosis and intimal hyperplasia to maintain patency. These implants when in contact with blood face a challenge to oppose the natural coagulation process that becomes activated. Surface protein adsorption and their relevant 3D confirmation greatly determine the degree of blood compatibility. A great deal of research efforts are attributed towards realising such a surface, which comprise of a range of methods on surface modification. Surface modification methods can be broadly categorized as physicochemical modifications and biological modifications. These modifications aim to modulate platelet responses directly through modulation of thrombogenic proteins or by inducing antithrombogenic biomolecules that can be biofunctionalised onto surfaces or through inducing an active endothelium. Nanotechnology is recognising a great role in such surface modification of cardiovascular implants through biofunctionalisation of polymers and peptides in nanocomposites and through nanofabrication of polymers which will pave the way for finding a closer blood match through haemostasis when developing cardiovascular implants with a greater degree of patency.

  17. Oxygen-implanted induced formation of oxide layer enhances blood compatibility on titanium for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Wei-Chiang [School of Oral Hygiene, Taipei Medical University, Taipei 110, Taiwan (China); Department of Dentistry, Taipei Medical University Hospital, Taipei 110, Taiwan (China); Chang, Fang-Mo [School of Dentistry, Taipei Medical University, Taipei 110, Taiwan (China); Yang, Tzu-Sen [Master Program in Graduate Institute of Nanomedicine and Medical Engineering, Taipei Medical University, Taipei 110, Taiwan (China); Ou, Keng-Liang [School of Dentistry, Taipei Medical University, Taipei 110, Taiwan (China); Research Center for Biomedical Implants and Microsurgery Devices, Taipei Medical University, Taipei 110, Taiwan (China); Department of Dentistry, Taipei Medical University-Shuang-Ho Hospital, Taipei 235, Taiwan (China); Lin, Che-Tong [School of Dentistry, Taipei Medical University, Taipei 110, Taiwan (China); Peng, Pei-Wen, E-mail: apon@tmu.edu.tw [School of Dental Technology, Taipei Medical University, Taipei 110, Taiwan (China)

    2016-11-01

    Titanium dioxide (TiO{sub 2}) layers were prepared on a Ti substrate by using oxygen plasma immersion ion implantation (oxygen PIII). The surface chemical states, structure, and morphology of the layers were studied using X-ray photoelectron spectroscopy, X-ray diffraction, Raman microscopy, atomic force microscopy and scanning electron microscope. The mechanical properties, such as the Young's modulus and hardness, of the layers were investigated using nanoindentation testing. The Ti{sup 4+} chemical state was determined to be present on oxygen-PIII-treated surfaces, which consisted of nanocrystalline TiO{sub 2} with a rutile structure. Compared with Ti substrates, the oxygen-PIII-treated surfaces exhibited decreased Young's moduli and hardness. Parameters indicating the blood compatibility of the oxygen-PIII-treated surfaces, including the clotting time and platelet adhesion and activation, were studied in vitro. Clotting time assays indicated that the clotting time of oxygen-PIII-treated surfaces was longer than that of the Ti substrate, which was associated with decreased fibrinogen adsorption. In conclusion, the surface characteristics and the blood compatibility of Ti implants can be modified and improved using oxygen PIII. - Highlights: • The Ti{sup 4+} chemical state was determined to be present on oxygen-PIII-treated surfaces. • The nanocrystalline TiO{sub 2} with a rutile structure was formed on titanium surfaces. • A nanoporous TiO{sub 2} layer in the rutile phase prepared using oxygen PIII treatment can be used to prolong blood clot formation.

  18. Cooperative control of blood compatibility and re-endothelialization by immobilized heparin and substrate topography.

    Science.gov (United States)

    Ding, Yonghui; Yang, Meng; Yang, Zhilu; Luo, Rifang; Lu, Xiong; Huang, Nan; Huang, Pingbo; Leng, Yang

    2015-03-01

    A wide variety of environmental cues provided by the extracellular matrix, including biophysical and biochemical cues, are responsible for vascular cell behavior and function. In particular, substrate topography and surface chemistry have been shown to regulate blood and vascular compatibility individually. The combined impact of chemical and topographic cues on blood and vascular compatibility, and the interplay between these two types of cues, are subjects that are currently being explored. In the present study, a facile polydopamine-mediated approach is introduced for immobilization of heparin on topographically patterned substrates, and the combined effects of these cues on blood compatibility and re-endothelialization are systematically investigated. The results show that immobilized heparin and substrate topography cooperatively modulate anti-coagulation activity, endothelial cell (EC) attachment, proliferation, focal adhesion formation and endothelial marker expression. Meanwhile, the substrate topography is the primary determinant of cell alignment and elongation, driving in vivo-like endothelial organization. Importantly, combining immobilized heparin with substrate topography empowers substantially greater competitive ability of ECs over smooth muscle cells than each cue individually. Moreover, a model is proposed to elucidate the cooperative interplay between immobilized heparin and substrate topography in regulating cell behavior. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. A novel system for providing compatible blood to patients during surgery: "self-service" electronic blood banking by nursing staff.

    Science.gov (United States)

    Cheng, G; Chiu, D S; Chung, A S; Wong, H F; Chan, M W; Lui, Y K; Choy, F M; Chan, J C; Chan, A H; Lam, S T; Fan, T C

    1996-04-01

    A good blood bank must be able to provide compatible blood units promptly to operating room patients with minimal wastage. A "self-service" by nursing staff blood banking system that is safe, efficient, and well-accepted has been developed. Specific blood units are no longer assigned to surgical patients who have a negative pretransfusion antibody screen, irrespective of the type of surgery. A computer-generated list of the serial numbers of all group-identical blood units currently in the blood bank inventory is provided for each patient. The units themselves are not labeled with a patient's name. The group O list will be provided for group O patients, the group A list for group A patients, and so forth. Should the patient require transfusion during surgery, the operating room nurses go to the refrigerator, remove any group-identical unit, and check the serial number of the unit against the serial numbers on the patient's list. If the serial number is on that list, the blood bank will accept responsibility for compatibility. The system was implemented in 1995. Since implementation, a total of 2154 patients have undergone operations at this hospital. Thirty-two patients received more than 10 units of red cells each. There were no transfusion errors. The crossmatch-to-transfusion ratio was reduced from 1.67 to 1.12. Turnaround time for supplying additional or urgent units to patients in operating room was shortened from 33 to 2.5 minutes. There was no incidence of a blood unit's serial number not being on the list. Work by nurses and technical staff was reduced by nearly 50 percent. The "self-service" (by nursing staff) blood banking system described is safe and efficient. It saves staff time and can be easily set up.

  20. Post-test probability for neonatal hyperbilirubinemia based on umbilical cord blood bilirubin, direct antiglobulin test, and ABO compatibility results.

    Science.gov (United States)

    Peeters, Bart; Geerts, Inge; Van Mullem, Mia; Micalessi, Isabel; Saegeman, Veroniek; Moerman, Jan

    2016-05-01

    Many hospitals opt for early postnatal discharge of newborns with a potential risk of readmission for neonatal hyperbilirubinemia. Assays/algorithms with the possibility to improve prediction of significant neonatal hyperbilirubinemia are needed to optimize screening protocols and safe discharge of neonates. This study investigated the predictive value of umbilical cord blood (UCB) testing for significant hyperbilirubinemia. Neonatal UCB bilirubin, UCB direct antiglobulin test (DAT), and blood group were determined, as well as the maternal blood group and the red blood cell antibody status. Moreover, in newborns with clinically apparent jaundice after visual assessment, plasma total bilirubin (TB) was measured. Clinical factors positively associated with UCB bilirubin were ABO incompatibility, positive DAT, presence of maternal red cell antibodies, alarming visual assessment and significant hyperbilirubinemia in the first 6 days of life. UCB bilirubin performed clinically well with an area under the receiver-operating characteristic curve (AUC) of 0.82 (95 % CI 0.80-0.84). The combined UCB bilirubin, DAT, and blood group analysis outperformed results of these parameters considered separately to detect significant hyperbilirubinemia and correlated exponentially with hyperbilirubinemia post-test probability. Post-test probabilities for neonatal hyperbilirubinemia can be calculated using exponential functions defined by UCB bilirubin, DAT, and ABO compatibility results. • The diagnostic value of the triad umbilical cord blood bilirubin measurement, direct antiglobulin testing and blood group analysis for neonatal hyperbilirubinemia remains unclear in literature. • Currently no guideline recommends screening for hyperbilirubinemia using umbilical cord blood. What is New: • Post-test probability for hyperbilirubinemia correlated exponentially with umbilical cord blood bilirubin in different risk groups defined by direct antiglobulin test and ABO blood group

  1. In vivo red blood cell compatibility testing using indium-113m tropolone-labeled red blood cells

    International Nuclear Information System (INIS)

    Morrissey, G.J.; Gravelle, D.; Dietz, G.; Driedger, A.A.; King, M.; Cradduck, T.D.

    1988-01-01

    In vivo radionuclide crossmatch is a method for identifying compatible blood for transfusion when allo- or autoantibodies preclude the use of conventional crossmatching techniques. A technique for labeling small volumes of donor red blood cells with [/sup 113m/In]tropolone is reported. The use of /sup 113m/In minimizes the accumulation of background radioactivity and the radiation dose especially so when multiple crossmatches are performed. Labeling red cells with [/sup 113m/In]tropolone is faster and easier to perform than with other radionuclides. Consistently high labeling efficiencies are obtained and minimal /sup 113m/In activity elutes from the labeled red blood cells. A case study involving 22 crossmatches is presented to demonstrate the technique. The radiation dose equivalent from /sup 113m/In is significantly less than with other radionuclides that may be used to label red cells

  2. Testing of Some Canine Blood Types in Transfusion Compatibility Assessment

    Directory of Open Access Journals (Sweden)

    L Ognean

    2014-01-01

    Full Text Available Blood types were determined using SHIGETA (n=136 and DEA1.1 (n=25 kits, in two groups of dogs, consisting of patients that underwent blood transfusions and healthy donors. The tests were conducted in accordance with the procedures established by the manufacturers, using specific monoclonal antibodies kits, heparinized blood for the tube agglutination (TUBE and slide (SLIDE methods, and EDTA treated blood for the CARD and chromatographic (CHROM methods. The clear expression of tube agglutination reaction in the SHIGETA kit provided a good detection of antigens. Positive reactions with anti-DEA1.1 were clear and evident with the CHROM test. SHIGETA tests revealed a predominance 1.1B (47.05% of blood type, common in Rotweilers (81.81% and Romanian Shepherds (73.68% and group 1(-B (24.26%, frequently found in German Shepherds (54.16%, these also representing an important source of compatible blood. DEA1.1 type test, revealed a high frequency of positive dogs (75%, associated with lower number of potential donors. Extrapolation of SHIGETA groups into the DEA system, confirmed the 1(-B positive dogs as DEA 1.1 negative, and their prevalence in German Shepherds also confirmed their known tendency to be “ideal donors”. The CHROME test showed a good efficiency in auto agglutination control and detecting DEA1.1 positive dogs, including patients with severe forms of anemia.

  3. Zwitterionic sulfobetaine-grafted poly(vinylidene fluoride) membrane with highly effective blood compatibility via atmospheric plasma-induced surface copolymerization.

    Science.gov (United States)

    Chang, Yung; Chang, Wan-Ju; Shih, Yu-Ju; Wei, Ta-Chin; Hsiue, Ging-Ho

    2011-04-01

    Development of nonfouling membranes to prevent nonspecific protein adsorption and platelet adhesion is critical for many biomedical applications. It is always a challenge to control the surface graft copolymerization of a highly polar monomer from the highly hydrophobic surface of a fluoropolymer membrane. In this work, the blood compatibility of poly(vinylidene fluoride) (PVDF) membranes with surface-grafted electrically neutral zwitterionic poly(sulfobetaine methacrylate) (PSBMA), from atmospheric plasma-induced surface copolymerization, was studied. The effect of surface composition and graft morphology, electrical neutrality, hydrophilicity and hydration capability on blood compatibility of the membranes were determined. Blood compatibility of the zwitterionic PVDF membranes was systematically evaluated by plasma protein adsorption, platelet adhesion, plasma-clotting time, and blood cell hemolysis. It was found that the nonfouling nature and hydration capability of grafted PSBMA polymers can be effectively controlled by regulating the grafting coverage and charge balance of the PSBMA layer on the PVDF membrane surface. Even a slight charge bias in the grafted zwitterionic PSBMA layer can induce electrostatic interactions between proteins and the membrane surfaces, leading to surface protein adsorption, platelet activation, plasma clotting and blood cell hemolysis. Thus, the optimized PSBMA surface graft layer in overall charge neutrality has a high hydration capability and the best antifouling, anticoagulant, and antihemolytic activities when comes into contact with human blood. © 2011 American Chemical Society

  4. Development of segmented polyurethane elastomers with low iodine content exhibiting radiopacity and blood compatibility.

    Science.gov (United States)

    Dawlee, S; Jayabalan, Muthu

    2011-10-01

    Biofunctionally active and inherently radiopaque polymers are the emerging need for biomedical applications. Novel segmented polyurethane elastomer with inherent radiopacity was prepared using aliphatic chain extender 2,3-diiodo-2-butene-1,4-diol, polyol polytetramethylene glycol and 4,4'-methylenebis(phenyl isocyanate) (MDI) for blood compatible applications. Aliphatic polyurethane was also prepared using hexamethylene diisocyanate for comparison. X-ray analysis of the polyurethanes revealed good radiopacity even at a relatively low concentration of 3% iodine in aromatic polyurethane and 10% in aliphatic polyurethane. The polyurethanes also possessed excellent thermal stability. MDI-based polyurethane showed considerably higher tensile strength than the analogous HDI-based polyurethane. MDI-based aromatic polyurethane exhibited a dynamic surface morphology in aqueous medium, resulting in the segregation of hydrophilic domains which was more conducive to anti-thrombogenic properties. The polyurethane was cytocompatible with L929 fibroblast cells, non-hemolytic, and possessed good blood compatibility.

  5. Development of segmented polyurethane elastomers with low iodine content exhibiting radiopacity and blood compatibility

    International Nuclear Information System (INIS)

    Dawlee, S; Jayabalan, Muthu

    2011-01-01

    Biofunctionally active and inherently radiopaque polymers are the emerging need for biomedical applications. Novel segmented polyurethane elastomer with inherent radiopacity was prepared using aliphatic chain extender 2,3-diiodo-2-butene-1,4-diol, polyol polytetramethylene glycol and 4,4'-methylenebis(phenyl isocyanate) (MDI) for blood compatible applications. Aliphatic polyurethane was also prepared using hexamethylene diisocyanate for comparison. X-ray analysis of the polyurethanes revealed good radiopacity even at a relatively low concentration of 3% iodine in aromatic polyurethane and 10% in aliphatic polyurethane. The polyurethanes also possessed excellent thermal stability. MDI-based polyurethane showed considerably higher tensile strength than the analogous HDI-based polyurethane. MDI-based aromatic polyurethane exhibited a dynamic surface morphology in aqueous medium, resulting in the segregation of hydrophilic domains which was more conducive to anti-thrombogenic properties. The polyurethane was cytocompatible with L929 fibroblast cells, non-hemolytic, and possessed good blood compatibility.

  6. Development of segmented polyurethane elastomers with low iodine content exhibiting radiopacity and blood compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Dawlee, S; Jayabalan, Muthu, E-mail: muthujayabalan@rediffmail.com [Polymer Science Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala 695 012 (India)

    2011-10-15

    Biofunctionally active and inherently radiopaque polymers are the emerging need for biomedical applications. Novel segmented polyurethane elastomer with inherent radiopacity was prepared using aliphatic chain extender 2,3-diiodo-2-butene-1,4-diol, polyol polytetramethylene glycol and 4,4'-methylenebis(phenyl isocyanate) (MDI) for blood compatible applications. Aliphatic polyurethane was also prepared using hexamethylene diisocyanate for comparison. X-ray analysis of the polyurethanes revealed good radiopacity even at a relatively low concentration of 3% iodine in aromatic polyurethane and 10% in aliphatic polyurethane. The polyurethanes also possessed excellent thermal stability. MDI-based polyurethane showed considerably higher tensile strength than the analogous HDI-based polyurethane. MDI-based aromatic polyurethane exhibited a dynamic surface morphology in aqueous medium, resulting in the segregation of hydrophilic domains which was more conducive to anti-thrombogenic properties. The polyurethane was cytocompatible with L929 fibroblast cells, non-hemolytic, and possessed good blood compatibility.

  7. Are hospital quality improvement and public accountability compatible?

    Science.gov (United States)

    Panzer, R J

    1994-07-01

    The goals of public accountability and quality improvement are compatible in theory but not necessarily in practice. Both concepts emphasize the customer. However, those working toward these two goals design systems with quite different roles and relationships between the providers and consumers of health care. Superficial interactions obstruct meaningful dialogue about how to build a better system meeting both sets of goals. Current practices of public accountability and quality improvement have fundamentally different paradigms concerning the roles and responsibilities of those who provide and those who consume health care. There are at least three ways to improve the current relationship between public accountability and quality improvement. First, optimizing the design and performance of each effort would be an improvement since the goals are highly compatible. Neither ideal currently meets its own expectations, creating distrust among the proponents of each when reality falls short. Second, the two efforts could be coordinated through joint community-level planning and sharing. Finally and optimally, the two concepts could be made part of the same community-level cooperative system, an approach that offers the greatest opportunity for achieving shared goals.

  8. Comparative Analysis of Compatibility Effects on Invigorating Blood Circulation for Cyperi Rhizoma Series of Herb Pairs Using Untargeted Metabolomics

    Directory of Open Access Journals (Sweden)

    Pei Liu

    2017-09-01

    Full Text Available The mutual-assistance compatibility of Cyperi Rhizoma (Xiangfu, XF and Angelicae Sinensis Radix (Danggui, DG, Chuanxiong Rhizoma (Chuanxiong, CX, Paeoniae Radix Alba (Baishao, BS, or Corydalis Rhizoma (Yanhusuo, YH, found in a traditional Chinese medicine (TCM named Xiang-Fu-Si-Wu Decoction (XFSWD, can produce synergistic and promoting blood effects. Nowadays, XFSWD has been proved to be effective in activating blood circulation and dissipating blood stasis. However, the role of the herb pairs synergistic effects in the formula were poorly understood. In order to quantitatively assess the compatibility effects of herb pairs, mass spectrometry-based untargeted metabolomics studies were performed. The plasma and urine metabolic profiles of acute blood stasis rats induced by adrenaline hydrochloride and ice water and administered with Cyperi Rhizoma—Angelicae Sinensis Radix (XD, Cyperi Rhizoma—Chuanxiong Rhizoma (XC, Cyperi Rhizoma—Paeoniae Radix Alba (XB, Cyperi Rhizoma—Corydalis Rhizoma (XY were compared. Relative peak area of identified metabolites was calculated and principal component analysis (PCA score plot from the potential markers was used to visualize the overall differences. Then, the metabolites results were used with biochemistry indicators and genes expression values as parameters to quantitatively evaluate the compatibility effects of XF series of herb pairs by PCA and correlation analysis. The collective results indicated that the four XF herb pairs regulated glycerophospholipid metabolism, steroid hormone biosynthesis and arachidonic acid metabolism pathway. XD was more prominent in regulating the blood stasis during the four XF herb pairs. This study demonstrated that metabolomics was a useful tool to efficacy evaluation and compatibility effects of TCM elucidation.

  9. Studies on in vitro biostability and blood compatibility of polyurethane potting compound based on aromatic polymeric MDI for extracorporeal devices.

    Science.gov (United States)

    Hridya, V K; Jayabalan, M

    2009-12-01

    Polyurethane potting compound based on aromatic isocyanurate of polymeric MDI, poly propylene glycol (PPG400) and trimethylol propane (TMP) has significant favourable properties, good pot life and setting characteristics. The cured potting compound of this formulation has appreciable thermal stability and mechanical properties. In vitro biostability of cured potting compound has been found to be excellent without any significant degradation in simulated physiological media and chemical environment. Studies on blood-material interaction and cytotoxicity reveal in vitro blood compatibility and compatibility with cells of this potting compound.

  10. Surface coating for blood-contacting devices

    Science.gov (United States)

    Nair, Ajit Kumar Balakrishnan

    The major problems always encountered with the blood-contacting surfaces are their compatibility, contact blood damage, and thrombogenicity. Titanium nitride (TiN) is a hard, inert, ceramic material that is widely used in the engineering industry. TiN has been proven to be a good biomaterial in its crystalline form, in orthopedic, and in tissue implant applications. This dissertation describes a method to coat amorphous TiN on the blood-contacting surfaces of certain medical devices using the room-temperature sputtering process and to characterize, to test, and to evaluate the coating for a reliable, durable, and compatible blood-contacting surface The blood-compatibility aspects were evaluated with standard, established protocols and procedures to prove the feasibility. An amorphous TiN coating is developed, characterized, tested, and blood compatibility evaluated by applying to the blood-contacting surfaces of stainless steel, catheters, and blood filters. The flexibility characteristics were proven by applying it to the diaphragms of the pulsatile pneumatic ventricular assist device. The results show that amorphous titanium nitride is flexible and adherent to polymeric substrates like polyurethane and polyester. Blood compatibility evaluation showed comparable results with catheters and superior behavior with stainless steel and polyester filters. It is concluded that amorphous titanium nitride can be considered to be applied to the surfaces of some of the medical devices in order to improve blood compatibility.

  11. The in vivo blood compatibility of bio-inspired small diameter vascular graft: effect of submicron longitudinally aligned topography

    Science.gov (United States)

    2013-01-01

    Background Cardiovascular disease is the leading cause of deaths worldwide and the arterial reconstructive surgery remains the treatment of choice. Although large diameter vascular grafts have been widely used in clinical practices, there is an urgent need to develop a small diameter vascular graft with enhanced blood compatibility. Herein, we fabricated a small diameter vascular graft with submicron longitudinally aligned topography, which mimicked the tunica intima of the native arterial vessels and were tested in Sprague–Dawley (SD) rats. Methods Vascular grafts with aligned and smooth topography were prepared by electrospinning and were connected to the abdominal aorta of the SD rats to evaluate their blood compatibility. Graft patency and platelet adhesion were evaluated by color Doppler ultrasound and immunofluorescence respectively. Results We observed a significant higher patency rate (p = 0.021) and less thrombus formation in vascular graft with aligned topography than vascular graft with smooth topography. However, no significant difference between the adhesion rates on both vascular grafts (smooth/aligned: 0.35‰/0.12‰, p > 0.05) was observed. Moreover, both vascular grafts had few adherent activated platelets on the luminal surface. Conclusion Bionic vascular graft showed enhanced blood compatibility due to the effect of surface topography. Therefore, it has considerable potential for using in clinical application. PMID:24083888

  12. Surface modifying of microporous PTFE capillary for bilirubin removing from human plasma and its blood compatibility

    International Nuclear Information System (INIS)

    Jin Gu; Yao Qizhi; Zhang Shanzi; Zhang Lei

    2008-01-01

    In this study, human serum albumin (HSA) was covalently immobilized onto the inner surface of microporous poly(tetrafluoroethylene) (MPTFE) capillaries for direct bilirubin removal from human plasma. To obtain active binding sites for HSA, the MPTFE capillaries were chemically functionalized by using a coating of poly(vinyl alcohol) (PVA)-glycidyl methacrylate (GMA) copolymers. Characterization of grafted MPTFE capillaries was verified by XPS, Fourier transform infrared spectroscopy (FT-IR), scanning electronic microscopy (SEM). Non-specific adsorption on the PVA-GMA coated capillary remains low (< 0.38 mg bilirubin/g), and higher affinity adsorption capacity, of up to 73.6 mg bilirubin/g polymer was obtained after HSA is immobilized. Blood compatibility of the grafted MPTFE capillary was evaluated by SEM and platelet rich plasma (PRP) contacting experiments. The experimental data on blood compatibility indicated that PVA-coated and PVA-GMA-HSA coated PTFE capillary showed a sharp suppress on platelets adhesion. The proposed method has the potential of serving in bilirubin removal in clinical application

  13. Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering.

    Science.gov (United States)

    Qi, Jie; Zhang, Huang; Wang, Yingzhou; Mani, Mohan Prasath; Jaganathan, Saravana Kumar

    2018-01-01

    Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. In this study, the hybrid scaffold based on polyvinyl alcohol (PVA) blended with metallocene polyethylene (mPE) and plectranthus amboinicus (PA) was fabricated for bone tissue engineering via electrospinning. The fabricated hybrid nanocomposites were characterized by scanning electron microscopy (SEM), Fourier transform and infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), contact angle measurement, and atomic force microscopy (AFM). Furthermore, activated partial thromboplastin time (APTT), prothrombin time (PT), and hemolytic assays were used to investigate the blood compatibility of the prepared hybrid nanocomposites. The prepared hybrid nanocomposites showed reduced fiber diameter (238±45 nm) and also increased porosity (87%) with decreased pore diameter (340±86 nm) compared with pure PVA. The interactions between PVA, mPE, and PA were identified by the formation of the additional peaks as revealed in FTIR. Furthermore, the prepared hybrid nanocomposites showed a decreased contact angle of 51°±1.32° indicating a hydrophilic nature and exhibited lower thermal stability compared to pristine PVA. Moreover, the mechanical results revealed that the electrospun scaffold showed an improved tensile strength of 3.55±0.29 MPa compared with the pristine PVA (1.8±0.52 MPa). The prepared hybrid nanocomposites showed delayed blood clotting as noted in APTT and PT assays indicating better blood compatibility. Moreover, the hemolysis assay revealed that the hybrid nanocomposites exhibited a low hemolytic index of 0.6% compared with pure PVA, which was 1.6% suggesting the safety of the developed nanocomposite to red blood cells (RBCs). The prepared nanocomposites exhibited better physico

  14. The Work Compatibility Improvement Framework: theory and application of improvement action and intervention strategies.

    Science.gov (United States)

    Genaidy, Ash M; Rinder, Magda M; Sequeira, Reynold; A-Rehim, Amal D

    2009-05-01

    Challenges facing management of manufacturing firms can be transformed into asset gains by giving careful consideration to the worker-work environment interface. The benefits of a 'healthy' interface may lead to sizable reductions in rising health care costs and retention of highly qualified workers. This paper presents a novel approach for the 'improve' phase of the Work Compatibility Improvement Framework. The work tasks of this research consisted of: (a) fundamentals of cognitive-based improvement action and intervention; (b) design concepts and process of improvement action/intervention generation; (c) assessment model of estimated gains in company's assets; (d) application demonstration in the manufacturing sector. The process of improvement action/intervention generation is described, preceded by a description of the fundamentals of cognitive-based improvement action and intervention and system architecture. This is followed by a documentation of estimated asset gains as a result of the improvement plan. The results showed that expert workers were, on average, 78% in agreement with the algorithm-identified improvement actions. Their knowledge was used to update the recommended actions as well as to detail the multiple strategies required to address the improvement actions. As a result, an integrated improvement plan was developed resulting in estimated asset gains of $1.6 million, which was validated by the general manager. The research reported herein documented the theory and application of the 'improve' phase of the Work Compatibility Improvement Framework. The economic assessment of the suggested improvement is also reported and this has proved to be an important driver to secure the firm collaboration of manufacturing enterprise management. An integrated improvement solution plan backed by a detailed economic assessment of suggested improvements is essential to demonstrate the full potential of workplace micro- and macro-ergonomic interventions.

  15. A highly stable blood meal alternative for rearing Aedes and Anopheles mosquitoes.

    Directory of Open Access Journals (Sweden)

    Ted Baughman

    2017-12-01

    Full Text Available We investigated alternatives to whole blood for blood feeding of mosquitoes with a focus on improved stability and compatibility with mass rearing programs. In contrast to whole blood, an artificial blood diet of ATP-supplemented plasma was effective in maintaining mosquito populations and was compatible with storage for extended periods refrigerated, frozen, and as a lyophilized powder. The plasma ATP diet supported rearing of both Anopheles and Aedes mosquitoes. It was also effective in rearing Wolbachia-infected Aedes mosquitoes, suggesting compatibility with vector control efforts.

  16. Blood Mixing Upregulates Platelet Membrane-Bound CD40 Ligand Expression in vitro Independent of Abo Compatibility.

    Science.gov (United States)

    Huang, Go-Shine; Hu, Mei-Hua; Lin, Tso-Chou; Lin, Yi-Chang; Tsai, Yi-Ting; Lin, Chih-Yuan; Ke, Hung-Yen; Zheng, Xu-Zhi; Tsai, Chien-Sung

    2017-11-30

    Platelets play a central role in the inflammation response via CD40 ligand (CD40L) expression, which may lead to transfusion reactions. The precise role of platelet CD40L-mediated inflammation in transfusion reactions is unclear. Therefore, we assessed the effects of in vitro blood mixing on platelet CD40L expression. In addition, we examined the effect of ABO compatibility on CD40L expression. Donor packed red blood cells were acquired from a blood bank, and recipient blood was obtained from patients undergoing cardiac surgery and prepared as washed platelets. Donor blood was mixed with suspended, washed recipient platelets to obtain a final mixing ratio of 1%, 5%, or 10% (vol/vol). The blood mixtures were divided into three groups: Group M, cross-matched blood-type mixing (n = 20); Group S, ABO type-specific uncross-matched blood (n = 20); and Group I, ABO incompatibility (not ABO type-specific blood and not process cross-matched) mixing (n = 20). The blood mixtures were used to detect platelet membrane-bound CD40L expression by flow cytometry. Blood mixing resulted in an increase in CD40L expression in Group M (P role in the induction of CD40L expression.

  17. Selecting K compatible blood components for transfusion can prevent anti-K immunization in women of childbearing age.

    Directory of Open Access Journals (Sweden)

    Andreja Hrašovec-Lampret

    2016-07-01

    Full Text Available With selecting K compatible blood for transfusion, we prevent K immunization and many unnecessary prenatal testing and gynecological examinations for at least 78% of pregnant women with K negative partners, whose fetus is not at risk of hemolytic disease of fetus and newborn. Abstract  Background Kell antibodies are beside RhD and c antibodies one of most clinically important antibodies that can cause severe hemolytic disease of the fetus and newborn (HDFN in pregnancy,which is still remaining one of the major causes of perinatal morbidity and mortality. Therefore, pregnant women with eryhrocyte alloantibodies anti-K need many prenatal testing and gynecological examinations. The major cause for anti-K immunisation is transfusion of incompatible blood in the past.    Methods We analysed retrospectively the data of 71 pregnant woman with alloantibodies anti-K, which were followed in Blood Transfusion Centre of Slovenia from 2004 -2014. We collected data of partner´s phenotype and woman´s transfusion history. Data were statistically analyzed with basic statistical methods.   Results 61 out of 71 partners were tested (86% and 48 were K negative (78%.The transfusion history was available for only 23 women (32%. The transfusion history was available for 23 out of 48 women with K negative partner (48%. All of them were transfused. 78% received incompatible-K positive blood, for the rest 22% women donations they received were not K typed.    Conclusions From the obtained data, we found that in 78% of cases cause for K alloimunnization is transfusion of K incompatible blood in past. With selecting K compatible blood for transfusion, we can prevent K immunization and many unnecessary prenatal testing and gynecological examinations for 78% pregnant women with K negative partners . 

  18. Study on plasma pre-functionalized PVC film grafted with TiO2/PVP to improve blood compatible and antibacterial properties

    International Nuclear Information System (INIS)

    Suganya, Arjunan; Shanmugavelayutham, Gurusamy; Rodríguez, Carmen Serra

    2017-01-01

    Research into the design of new biopolymers/polymer functionalized with nanoparticles is of tremendous interest to the medical sector, particularly with regard to blood-contacting devices. In this present study, a steady blood compatible and active antibacterial coating was fabricated by the grafting of titanium dioxide (TiO 2 )/polyvinylpyyrolidone (PVP) onto a polyvinyl chloride (PVC) film surface via the direct-current glow discharge plasma method. To enhance the chemical interaction between TiO 2 /PVP and PVC, the surfaces of the PVC films were functionalized by different plasmas (air, argon, and oxygen) before coating. In this study, the plasma parameters were varied, such as treatment time of about 5–20 min for a constant power of 100 W, potential 300 V, and a constant gas pressure of 2 Pa for air, argon, and oxygen gas environment. Then, the different plasma treatments on the PVC films, TiO 2 /PVP were grafted using a simple dip-coating method. In addition, the TiO 2 /PVP-grafted PVC films were characterized by contact angle, attenuated total reflectance Fourier transform infrared spectroscopy, field-emission scanning electron microscope, and x-ray photo electron spectroscopy. Importantly, TiO 2 /PVP is grafted onto the PVC surface due to the plasma-based retained functionality and demonstrates adhesive efficiency, which was observed by XPS. The bio-stability of the TiO 2 /PVP-modified PVC film was evaluated by in vitro platelet activation analysis and protein adsorption analysis. Then, the antibacterial properties were evaluated by the agar diffusion method against Escherichia coli . The result reveals that the grafting of TiO 2 /PVP was slightly higher for the 15 min oxygen plasma-functionalized PVC, which significantly decreases the platelet adhesion and protein adsorption. Moreover, the antibacterial properties of the 15 min oxygen plasma-functionalized PVC with TiO 2 /PVP-grafted film is also greatly improved compared with an air- and argon

  19. Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA for bone tissue engineering

    Directory of Open Access Journals (Sweden)

    Qi J

    2018-05-01

    PE, and PA were identified by the formation of the additional peaks as revealed in FTIR. Furthermore, the prepared hybrid nanocomposites showed a decreased contact angle of 51°±1.32° indicating a hydrophilic nature and exhibited lower thermal stability compared to pristine PVA. Moreover, the mechanical results revealed that the electrospun scaffold showed an improved tensile strength of 3.55±0.29 MPa compared with the pristine PVA (1.8±0.52 MPa. The prepared hybrid nanocomposites showed delayed blood clotting as noted in APTT and PT assays indicating better blood compatibility. Moreover, the hemolysis assay revealed that the hybrid nanocomposites exhibited a low hemolytic index of 0.6% compared with pure PVA, which was 1.6% suggesting the safety of the developed nanocomposite to red blood cells (RBCs. Conclusion: The prepared nanocomposites exhibited better physico-chemical properties, sufficient porosity, mechanical strength, and blood compatibility, which favors it as a valuable candidate in bone tissue engineering for repairing the bone defects. Keywords: scaffold, electrospinning, bone tissue engineering, physico-chemical characterization, blood compatibility

  20. Rational Clinical Use of Blood and Blood products – A summary

    Directory of Open Access Journals (Sweden)

    D Ghartimagar

    2017-03-01

    Full Text Available Blood transfusion is an essential therapeutic intervention. The main role of the blood centre is to provide safe and timely blood and blood component(s to the patients that will improve the physiological status of the patient. Various blood components can be harvested from a single donation of whole blood. The blood centre ensures that there is an adequate inventory of all blood types and blood components to meet the needs of the patients. The blood centre does donor selection, blood collection, component preparation, screening for transfusion – transmitted infections and blood processing. Serologically compatible blood and components are provided to the patients after meticulous pre-transfusion testing as per the standard protocol. Rational use of blood and blood products means right product is used with the right dose on right time for the right reason.

  1. Evaluation of mechanism of non-thermal plasma effect on the surface of polypropylene films for enhancement of adhesive and hemo compatible properties

    Energy Technology Data Exchange (ETDEWEB)

    Navaneetha Pandiyaraj, K., E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L& T by pass, Chinniyam Palayam (post), Coimbatore-641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai-400 019 (India); Arunkumar, A.; Ramkumar, M.C. [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L& T by pass, Chinniyam Palayam (post), Coimbatore-641062 (India); Ruzybayev, I.; Ismat Shah, S. [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark (United States); Su, Pi-Guey [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Periayah, Mercy Halleluyah; Halim, A.S. [School of Medical Sciences, Health Campus, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2015-08-30

    Highlights: • Investigated the mechanism of effect of various gaseous plasma treatments on the surface properties of Polypropylene (PP) films. • The improvement in surface energy is basically due to the incorporation of polar functional groups onto the PP films. • The extent of surface modification and hydrophobic recovery depends upon the type of plasma forming gas. • Due to the significant morphological and chemical changes induced by the gaseous plasma treatment, improved the blood compatibility as well as adhesive strength of the PP films. - Abstract: The hydro-carbon based polymers have attracted attention of scientists for its use in bio-medical field as various implants due to inherent flexibility. However, they have poor surface properties; particularly they have low surface energy (SE). Hence, blood components (platelets, blood proteins, etc.)-polymer surface interaction is the major concern when it comes in contact with blood. Thus, surface modification is required to develop the perfect antithrombogenic property without affecting the materials bulk. The present study describes the improvement in adhesive and blood compatible properties of polypropylene (PP) by low temperature (non-thermal) plasma of various gases such as Ar, O{sub 2}, air and Ar + O{sub 2} for biomedical applications. The changes in surface morphological, chemical and hydrophilic modification induced by the gaseous plasma treatment were analyzed by atomic force microscopy (AFM), X-ray photo electron spectroscopy (XPS), electron spin resonance (ESR) spectroscopy and contact angle measurements, respectively. Moreover, the stability of plasma effect was also studied for the different storage conditions. Variation in adhesive strength of the plasma treated PP film was studied by T-Peel and Lap-Shear strength tests. The blood compatibility of the surface modified PP films was investigated by in vitro analysis. It was found that gaseous plasma treatment improved the blood compatibility

  2. Evaluation of mechanism of non-thermal plasma effect on the surface of polypropylene films for enhancement of adhesive and hemo compatible properties

    International Nuclear Information System (INIS)

    Navaneetha Pandiyaraj, K.; Deshmukh, R.R.; Arunkumar, A.; Ramkumar, M.C.; Ruzybayev, I.; Ismat Shah, S.; Su, Pi-Guey; Periayah, Mercy Halleluyah; Halim, A.S.

    2015-01-01

    Highlights: • Investigated the mechanism of effect of various gaseous plasma treatments on the surface properties of Polypropylene (PP) films. • The improvement in surface energy is basically due to the incorporation of polar functional groups onto the PP films. • The extent of surface modification and hydrophobic recovery depends upon the type of plasma forming gas. • Due to the significant morphological and chemical changes induced by the gaseous plasma treatment, improved the blood compatibility as well as adhesive strength of the PP films. - Abstract: The hydro-carbon based polymers have attracted attention of scientists for its use in bio-medical field as various implants due to inherent flexibility. However, they have poor surface properties; particularly they have low surface energy (SE). Hence, blood components (platelets, blood proteins, etc.)-polymer surface interaction is the major concern when it comes in contact with blood. Thus, surface modification is required to develop the perfect antithrombogenic property without affecting the materials bulk. The present study describes the improvement in adhesive and blood compatible properties of polypropylene (PP) by low temperature (non-thermal) plasma of various gases such as Ar, O 2 , air and Ar + O 2 for biomedical applications. The changes in surface morphological, chemical and hydrophilic modification induced by the gaseous plasma treatment were analyzed by atomic force microscopy (AFM), X-ray photo electron spectroscopy (XPS), electron spin resonance (ESR) spectroscopy and contact angle measurements, respectively. Moreover, the stability of plasma effect was also studied for the different storage conditions. Variation in adhesive strength of the plasma treated PP film was studied by T-Peel and Lap-Shear strength tests. The blood compatibility of the surface modified PP films was investigated by in vitro analysis. It was found that gaseous plasma treatment improved the blood compatibility as well

  3. Improvement of antithrombogenicity of a fluoro polymer by radiation-induced grafting of hydrophilic monomer

    International Nuclear Information System (INIS)

    Otsuhata, Kazushige; Razzak, M.T.; Tabata, Yoneho; Ohashi, Fumito; Takeuchi, Atsushi.

    1985-01-01

    Fluoro polymers have been used as biomaterials in medical field since they have good compatibility with both tissue and blood, and their biomaterial application are of variety. Blood compatibility of fluoro polymers, however, are not always enough for every applications. Especially, there is a large difficulty in the application for artificial vessel with small radius below than 4 mm. In the present study, grafting of a hydrophilic monomer onto a fluoro polymer has been carried out to improve blood compatibility of the fluoro polymer. The technique of grafting employed here was simultaneous irradiation method of gamma rays from a 60 Co source. The fluoro polymer and the hydrophilic monomer used in the experiment were alternative copolymer of ethylene and tetrafluoethylene(AFLON) and N,N-dimethylacry lamide(DMAA), respectively. After grafting, it was found by in vitro tests that antithrombogenicity of AFLON was improved by grafting of DMAA. It was, however, also found that degree of the improvement is affected by grafting conditions. When ethyl acetate was used as a solvent for the graft copolymerization, the improvement was affected by dose rate. Blood compatibility of DMAA-g-AFLON obtained at a higher dose rate of 1 x 10 5 rad/h was not improved, while it was improved in the sample of DMAA-g-AFLON obtained at a lower dose rate of 1 x 10 4 rad/h. On the other hand, when acetone was used as a solvent for the grafting, the degree of grafting gave a significant effect on the improvement. Blood compatibility of all samples with grafting percent more than 20 % was improved by grafting of DMAA. (author)

  4. Improvement of crash compatibility between cars

    NARCIS (Netherlands)

    Huibers, J.A.H.M.; Faerber, E.; Cesari, D.; Hobbs, A.C.; Kampen, B. van; Paez, J.; Wykes, N.J.

    1998-01-01

    This paper will provide an overview of the research work of the European Enhanced Vehicle-safety Committee (EEVC) in the field of crash compatibility between passenger cars. Since July 1997 the EC Commission is partly funding the research work of EEVC. The running period of this project will be two

  5. Preparation and characterization of chitosan-heparin composite matrices for blood contacting tissue engineering

    International Nuclear Information System (INIS)

    He Qing; Gong Kai; Gong Yandao; Zhang Xiufang; Ao Qiang; Zhang Lihai; Hu Min

    2010-01-01

    Chitosan has been widely used for biomaterial scaffolds in tissue engineering because of its good mechanical properties and cytocompatibility. However, the poor blood compatibility of chitosan has greatly limited its biomedical utilization, especially for blood contacting tissue engineering. In this study, we exploited a polymer blending procedure to heparinize the chitosan material under simple and mild conditions to improve its antithrombogenic property. By an optimized procedure, a macroscopically homogeneous chitosan-heparin (Chi-Hep) blended suspension was obtained, with which Chi-Hep composite films and porous scaffolds were fabricated. X-ray photoelectron spectroscopy and sulfur elemental analysis confirmed the successful immobilization of heparin in the composite matrices (i.e. films and porous scaffolds). Toluidine blue staining indicated that heparin was distributed homogeneously in the composite matrices. Only a small amount of heparin was released from the matrices during incubation in normal saline for 10 days. The composite matrices showed improved blood compatibility, as well as good mechanical properties and endothelial cell compatibility. These results suggest that the Chi-Hep composite matrices are promising candidates for blood contacting tissue engineering.

  6. The anticoagulant ability of ferulic acid and its applications for improving the blood compatibility of silk fibroin

    Energy Technology Data Exchange (ETDEWEB)

    Wang Song; Gao Zhen; Chen Xiaomeng; Lian Xiaojie; Zhu Hesun [School of Material Science and Engineering, Beijing Institute of Technology, Beijing 100081 (China); Zheng Jun; Sun Lizhong [Department of Cardiac Surgery, Cardiovascular Institute and Fu Wai Hospital, CAMS and PUMC, Beijing 100037 (China)], E-mail: wangsongbit@hotmail.com

    2008-12-15

    The hemocompatibility of silk fibroin (SF) was improved with ferulic acid (FA) by graft polymerization. Ferulic acid is an active ingredient of many Chinese herbal medicines, such as Chuanxiong (Rhizoma ligustici wallichii), Danggui (Angelica sinensis) and Awei (Asafoetida giantfennel), which have been used to treat cardiovascular diseases by Chinese physicians for thousands of years. The inhibitory functions of FA on blood coagulation and erythrocyte agglutination were first characterized by a Lee-White test tube method and a micropipette technique, respectively. Then, FA was immobilized on SF by graft polymerization and the surface composition of modified SF was characterized by attenuated total reflectance Fourier-transform infrared (ATR-FTIR), x-ray photoelectron spectroscopy (XPS) and optical microscopy. The anticoagulant activity of modified SF was assessed, respectively, by in vitro clotting time measurements on a photo-optical clot detection instrument and with the Lee-White test tube method. The test results indicated that in comparison to untreated SF, the anticoagulant activity of modified SF has been improved significantly. Moreover, the SF surface composition is altered by FA but its {beta}-sheet conformation is not disturbed.

  7. Biocorrosion properties and blood and cell compatibility of pure iron as a biodegradable biomaterial.

    Science.gov (United States)

    Zhang, Erlin; Chen, Haiyan; Shen, Feng

    2010-07-01

    Biocorrosion properties and blood- and cell compatibility of pure iron were studied in comparison with 316L stainless steel and Mg-Mn-Zn magnesium alloy to reveal the possibility of pure iron as a biodegradable biomaterial. Both electrochemical and weight loss tests showed that pure iron showed a relatively high corrosion rate at the first several days and then decreased to a low level during the following immersion due to the formation of phosphates on the surface. However, the corrosion of pure iron did not cause significant increase in pH value to the solution. In comparison with 316L and Mg-Mn-Zn alloy, the pure iron exhibited biodegradable property in a moderate corrosion rate. Pure iron possessed similar dynamic blood clotting time, prothrombin time and plasma recalcification time to 316L and Mg-Mn-Zn alloy, but a lower hemolysis ratio and a significant lower number density of adhered platelets. MTT results revealed that the extract except the one with 25% 24 h extract actually displayed toxicity to cells and the toxicity increased with the increasing of the iron ion concentration and the incubation time. It was thought there should be an iron ion concentration threshold in the effect of iron ion on the cell toxicity.

  8. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  9. Comparative serological investigation between cat and tiger blood for transfusion.

    Science.gov (United States)

    Thengchaisri, Naris; Sinthusingha, Chayakrit; Arthitwong, Surapong; Sattasathuchana, Panpicha

    2017-06-29

    Evidence suggests that non-domesticated felids inherited the same AB-erythrocyte antigens as domestic cats. To study the possible compatibility of tiger blood with that of other endangered felidae, blood samples from captive tigers and domestic cats were subjected to an in vitro study. The objectives of this study were to (1) identify whether the captive tigers had blood type AB and (2) determine the compatibility between the blood of captive tigers and that of domestic cats with a similar blood type. The anti-coagulated blood with ethylenediaminetetraacetic acid of 30 tigers was examined to determine blood type, and a crossmatching test was performed between tiger and cat blood. All 30 tigers had blood type A. Tube agglutination tests using tiger plasma with cat erythrocytes resulted in 100% agglutination (n=30) with type B cat erythrocytes and 76.7% agglutination (n=23) with type A cat erythrocytes. The 80% of major and 60% of minor compatibilities between blood from 10 tigers and 10 domestic cats with blood type A were found to pass compatibility tests. Interestingly, 3/10 of the tigers' red blood cell samples were fully compatible with all cat plasmas, and 1/10 of the tiger plasma samples were fully compatible with the type A red cells of domestic cats. Although the result of present findings revealed type-A blood group in the surveyed tigers, the reaction of tiger plasma with Type-A red cell from cats suggested a possibility of other blood type in tigers.

  10. Electromagnetic Compatibility Design of the Computer Circuits

    Science.gov (United States)

    Zitai, Hong

    2018-02-01

    Computers and the Internet have gradually penetrated into every aspect of people’s daily work. But with the improvement of electronic equipment as well as electrical system, the electromagnetic environment becomes much more complex. Electromagnetic interference has become an important factor to hinder the normal operation of electronic equipment. In order to analyse the computer circuit compatible with the electromagnetic compatibility, this paper starts from the computer electromagnetic and the conception of electromagnetic compatibility. And then, through the analysis of the main circuit and system of computer electromagnetic compatibility problems, we can design the computer circuits in term of electromagnetic compatibility. Finally, the basic contents and methods of EMC test are expounded in order to ensure the electromagnetic compatibility of equipment.

  11. The Blood Compatibilities of Blood Purification Membranes and Other Materials Developed in Japan

    Directory of Open Access Journals (Sweden)

    Takaya Abe

    2011-01-01

    Full Text Available The biocompatibilities in blood purification therapy are defined as “a concept to stipulate safety of blood purification therapy by an index based on interaction in the body arising from blood purification therapy itself.” The biocompatibilities are associated with not only materials to be used but also many factors such as sterilization method and eluted substance. It is often evaluated based on impacts on cellular pathways and on humoral pathways. Since the biocompatibilities of blood purification therapy in particular hemodialysis are not just a prognostic factor for dialysis patients but a contributory factor for long-term complications, it should be considered with adequate attention. It is important that blood purification therapy should be performed by consistently evaluating not only risks associated with these biocompatibilities but also the other advantages obtained from treatments. In this paper, the biocompatibilities of membrane and adsorption material based on Japanese original which are used for blood purification therapy are described.

  12. Importance of manually entering blood glucose readings when wireless-compatible meters are not being used with an insulin pump.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Tang, Yuanyuan; Gill, Elizabeth C; Mitchell, Adela; Wright, Nancy; Deeb, Larry C

    2013-07-01

    The objective was to determine if there were differences in blood glucose monitoring (BGM) data downloaded from insulin pumps of patients who use meters that wirelessly transmit data to their insulin pumps (i.e., wireless group) and those who do not (i.e., nonwireless group). Blood glucose monitoring data were downloaded from the meters and insulin pumps of 47 children and adolescents with type 1 diabetes mellitus. Independent and paired t tests compared BGM data downloaded from meters and BGM data downloaded from insulin pumps. There were significant differences in BGM data downloaded from the insulin pumps of patients using wireless meters compared to those using nonwireless meters. Wireless patients appeared to engage in more BGM, had more low and in-range BG readings and fewer very high BG readingss than nonwireless patients. However, a comparison of BGM data downloaded from meters and insulin pumps of nonwireless patients indicated that their insulin pump data significantly underestimated the number of BGM readings conducted, as well as the number of low and in-range readings, while overestimating the number of very high BGM readings. Because patients who use nonwireless-compatible meters do not manually enter their low and in-range BGM readings into the insulin pump, BGM data downloaded only from pumps may provide an incomplete representation of BGM frequency or results. It is recommended that patients use meters that directly communicate with pumps or perform bolus calculations. Patients should be educated about the importance of manually entering all BGM readings if they do not use a wireless-compatible meter with their insulin pump. © 2013 Diabetes Technology Society.

  13. Survival of transfused red blood cells: In vivo compatibility testing with chromium-51

    International Nuclear Information System (INIS)

    Dharkar, D.D.; Pineda, A.A.

    1983-01-01

    The /sup 51/Cr red cell survival test and specific test for measurement of the disappearance rate of labeled red cells. This procedure can be used for the assessment of red cell compatibility testing in vivo. The authors recommend that more routine transfusions as well as ''difficult'' transfusions be monitored by /sup 51/Cr in vivo compatibility testing before the actual transfusions, so that more consistent and reliable survival values are achieved

  14. Processing and storage of blood components: strategies to improve patient safety

    Directory of Open Access Journals (Sweden)

    Pietersz RNI

    2015-08-01

    Full Text Available Ruby NI Pietersz, Pieter F van der Meer Department of Product and Process Development, Sanquin Blood Bank, Amsterdam, the Netherlands Abstract: This review focuses on safety improvements of blood processing of various blood components and their respective storage. A solid quality system to ensure safe and effective blood components that are traceable from a donor to the patient is the foundation of a safe blood supply. To stimulate and guide this process, National Health Authorities should develop guidelines for blood transfusion, including establishment of a quality system. Blood component therapy enabled treatment of patients with blood constituents that were missing, only thus preventing reactions to unnecessarily transfused elements. Leukoreduction prevents many adverse reactions and also improves the quality of the blood components during storage. The safety of red cells and platelets is improved by replacement of plasma with preservative solutions, which results in the reduction of isoantibodies and plasma proteins. Automation of blood collection, separation of whole blood into components, and consecutive processing steps, such as preparation of platelet concentrate from multiple donations, improves the consistent composition of blood components. Physicians can better prescribe the number of transfusions and therewith reduce donor exposure and/or the risk of pathogen transmission. Pathogen reduction in cellular blood components is the latest development in improving the safety of blood transfusions for patients. Keywords: blood components, red cell concentrates, platelet concentrates, plasma, transfusion, safety 

  15. Curcuma mangga-Mediated Synthesis of Gold Nanoparticles: Characterization, Stability, Cytotoxicity, and Blood Compatibility

    Directory of Open Access Journals (Sweden)

    Yiing Yee Foo

    2017-05-01

    Full Text Available The utilization of toxic chemicals as reducing and stabilizing agents in the preparation of gold nanoparticles (AuNPs has increased in vivo toxicity and thus limited its application in clinical settings. Herein, we propose an alternative method of preparing highly stable AuNPs, where non-toxic Curcuma mangga (CM extract was used as a single reducing and stabilizing agent to overcome the aforementioned constraints. The morphological images enunciated that the homogeneously dispersed AuNPs exhibited spherical morphology with an average particle diameter of 15.6 nm. Fourier Transform infrared (FTIR and cyclic voltammetry analysis demonstrated that carbonyl groups of terpenoids in CM extract played an important role in the formation and stabilization of AuNPs. Green-synthesized AuNPs were found to have good stability in physiological media after 24 h of dispersion. The AuNPs were also cytocompatible with human colon fibroblast cell (CCD-18Co and human lung fibroblast cell (MRC-5. Hemocompatibility tests revealed that the AuNPs were blood-compatible, with less than 10% of hemolysis without any aggregation of erythrocytes. The current study suggests potential in employing a CM-extract-based method in the preparation of AuNPs for anticancer diagnosis and therapy.

  16. Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.

    Science.gov (United States)

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2018-04-19

    Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

  17. Improved thermal cycling durability and PCR compatibility of polymer coated quantum dot

    International Nuclear Information System (INIS)

    Xun Zhe; Guan Yifu; Zhao Xiaoyun

    2013-01-01

    Quantum dots have experienced rapid development in imaging, labeling and sensing in medicine and life science. To be suitable for polymerase chain reaction (PCR) assay, we have tested QD thermal cycling durability and compatibility, which have not been addressed in previous reports. In this study, we synthesized CdSe/ZnS QDs with a surface modification with high-MW amphiphilic copolymers and observed that Mg 2+ ions in the PCR reaction could induce the QDs to precipitate and reduce their fluorescence signal significantly after thermal cycling. To overcome this problem, we used mPEG2000 to conjugate the QD surface for further protection, and found that this modification enables QDs to endure 40 thermal cycles in the presence of other components essential for PCR reactions. We have also identified that QDs have different effects on rTaq and Ex Taq polymerization systems. A high QD concentration could apparently reduce the PCR efficiency, but this inhibition was relieved significantly in the Ex PCR system as the concentration of Ex Taq polymerase was increased. Real-time PCR amplification results showed that QDs could provide a sufficiently measurable fluorescence signal without excessively inhibiting the DNA amplification. Based on this improved thermal cycling durability and compatibility with the PCR system, QDs have the potential to be developed as stable fluorescent sensors in PCR and real-time PCR amplification. (paper)

  18. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

    Science.gov (United States)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-01-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

  19. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    Science.gov (United States)

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  20. [Ischemic Changes in the Electrocardiogram and Circulatory Collapse Accompanied by Severe Anemia Owing to the Delay of Red Blood Cell Concentrate Transfusion in Two Patients with Intraoperative Massive Bleeding].

    Science.gov (United States)

    Horiuchi, Toshinori; Noguchi, Teruo; Kurita, Naoko; Yamaguchi, Ayako; Takeda, Masafumi; Sha, Keiichi; Nagahata, Toshihiro

    2016-01-01

    We present two patients developing intraoperative massive bleeding and showed ischemic changes in the electrocardiogram and circulatory collapse accompanied by severe anemia owing to the delay of red blood cell concentrate transfusion. One patient underwent hepatectomy and the other pancreaticoduodenectomy. Their lowest hemoglobin concentration was around 2 g x dl(-1), and they showed ischemic changes in the electrocardiogram and severe decreases in blood pressure. The former received compatible red blood cell concentrate and the latter received uncrossmatched same blood group red blood cell concentrate immediately, and their electrocardiogram and blood pressure quickly improved. To avoid life-threatening anemia, emergency red blood cell concentrate transfusion including compatible different blood group transfusion should be applied for intraoperative massive bleeding.

  1. BLOODR: blood donor and requester mobile application.

    Science.gov (United States)

    Tatikonda, Vamsi Krishna; El-Ocla, Hosam

    2017-01-01

    With rapid increase in the usage of social networks sites across the world, there is also a steady increase in blood donation requests as being noticed in the number of posts on these sites such as Facebook and twitter seeking blood donors. Finding blood donor is a challenging issue in almost every country. There are some blood donor finder applications in the market such as Blood app by Red Cross and Blood Donor Finder application by Neologix. However, more reliable applications that meet the needs of users are prompted. Several software technologies including languages and framework are used to develop our blood-donor web application known as BLOODR application. These technologies comprise Ruby programming language (simply known as Ruby) along with JavaScript and PostgreSQL for database are used. Ruby on Rails (simply known as Rails) is an open source Web framework that makes it possible to quickly and easily create data-based web applications. We show screenshots for the BLOODR application for different types of users including requester, donor, and administrator. Various features of the application are described and their needs of use are analyzed. If a patient needs a blood at a clinic, blood donors in vicinity can be contacted through using a clinic management service provided in this application. Registered donors will get notification for the blood requests only if their blood group is compatible with the requested blood type and in the same city/region. Then matching blood donors can go to the requesting clinic and donate. BLOODR application provides a reliable platform to connect local blood donors with patients. BLOODR creates a communication channel through authenticated clinics whenever a patient needs blood donation. It is a useful tool to find compatible blood donors who can receive blood request posts in their local area. Clinics can use this web application to maintain the blood donation activity. Future improvement of the BLOODR is explained.

  2. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Directory of Open Access Journals (Sweden)

    Senn Oliver

    2010-04-01

    Full Text Available Abstract Background Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Objective Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Outcome Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary. Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries. Methods/Design Randomised controlled study. Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system. Expected results/conclusion The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range ≤ 140/≤ 90 mmHg, yellow: blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg lead to better self-monitoring compared with the conventional (non-colour-coded blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. Trial registration ClinicalTrials.gov ID NCT01013467

  3. Compatible Lie Bialgebras

    International Nuclear Information System (INIS)

    Wu Ming-Zhong; Bai Cheng-Ming

    2015-01-01

    A compatible Lie algebra is a pair of Lie algebras such that any linear combination of the two Lie brackets is a Lie bracket. We construct a bialgebra theory of compatible Lie algebras as an analogue of a Lie bialgebra. They can also be regarded as a “compatible version” of Lie bialgebras, that is, a pair of Lie bialgebras such that any linear combination of the two Lie bialgebras is still a Lie bialgebra. Many properties of compatible Lie bialgebras as the “compatible version” of the corresponding properties of Lie bialgebras are presented. In particular, there is a coboundary compatible Lie bialgebra theory with a construction from the classical Yang–Baxter equation in compatible Lie algebras as a combination of two classical Yang–Baxter equations in Lie algebras. Furthermore, a notion of compatible pre-Lie algebra is introduced with an interpretation of its close relation with the classical Yang–Baxter equation in compatible Lie algebras which leads to a construction of the solutions of the latter. As a byproduct, the compatible Lie bialgebras fit into the framework to construct non-constant solutions of the classical Yang–Baxter equation given by Golubchik and Sokolov. (paper)

  4. Psychological compatibility of women's handball team

    Directory of Open Access Journals (Sweden)

    Shalar O.G.

    2010-02-01

    Full Text Available The results of study of psychological compatibility of womanish handball commands are presented. The psychological climate of command is investigational. Certain and adapted methods of estimation of psychological compatibility in the command playing types of sport. Psychological tests allow to expose the strong and weak sides of psychology of sportsmen. These information can be used for more effective program of psychological preparation of sportsmen development. It is necessary to improve determination of separate individual qualities of personality of sportsmen.

  5. The Work Compatibility Improvement Framework: an integrated perspective of the human-at-work system.

    Science.gov (United States)

    Genaidy, Ash; Salem, Sam; Karwowski, Waldemar; Paez, Omar; Tuncel, Setenay

    2007-01-15

    The industrial revolution demonstrated the limitations of a pure mechanistic approach towards work design. Human work is now seen as a complex entity that involves different scientific branches and blurs the line between mental and physical activities. Job design has been a traditional concern of applied psychology, which has provided insight into the interaction between the individual and the work environment. The goal of this paper is to introduce the human-at-work system as a holistic approach to organizational design. It postulates that the well-being of workers and work outcomes are issues that need to be addressed jointly, moving beyond traditional concepts of job satisfaction and work stress. The work compatibility model (WCM) is introduced as an engineering approach that seeks to integrate previous constructs of job and organizational design. The WCM seeks a balance between energy expenditure and replenishment. The implementation of the WCM in industrial settings is described within the context of the Work Compatibility Improvement Framework. A sample review of six models (motivation-hygiene theory; job characteristics theory; person-environment fit; demand-control model; and balance theory) provides the foundation for the interaction between the individual and the work environment. A review of three workload assessment methods (position analysis questionnaire, job task analysis and NASA task load index) gives an example of the foundation for the taxonomy of work environment domains. Previous models have sought to identify a balance state for the human-at-work system. They differentiated between the objective and subjective effects of the environment and the worker. An imbalance between the person and the environment has been proven to increase health risks. The WCM works with a taxonomy of 12 work domains classified in terms of the direct (acting) or indirect (experienced) effect on the worker. In terms of measurement, two quantitative methods are proposed

  6. Using Crossmatch tests for serological compatibility assessment intra- and interspecific at dogs and cats

    Directory of Open Access Journals (Sweden)

    Sergiu Adrian Muntean

    2016-11-01

    Conclusions: The intraspecific evaluations revealed a high level of blood compatibility in the case of dogs unsensitivized through previous blood transfusions, yet without excluding the possibility of some atypical sensitivization for clinical interest. Having all the interspecific tests exclusively highly positive, we can not sustain a probable xenotransfusion.

  7. Biomedical Nanoparticles: Overview of Their Surface Immune-Compatibility

    Directory of Open Access Journals (Sweden)

    Olimpia Gamucci

    2014-02-01

    Full Text Available Diagnostic- and therapeutic release-aimed nanoparticles require the highest degree of biocompatibility. Some physical and chemical characteristics of such nanomaterials are often at odds with this requirement. For instance, metals with specific features used as contrast agents in magnetic resonance imaging need particular coatings to improve their blood solubility and increase their biocompatibility. Other examples come from the development of nanocarriers exploiting the different characteristics of two or more materials, i.e., the ability to encapsulate a certain drug by one core-material and the targeting capability of a different coating surface. Furthermore, all these “human-non-self” modifications necessitate proofs of compatibility with the immune system to avoid inflammatory reactions and resultant adverse effects for the patient. In the present review we discuss the molecular interactions and responses of the immune system to the principal nanoparticle surface modifications used in nanomedicine.

  8. Improving blood sample logistics using simulation

    DEFF Research Database (Denmark)

    Jørgensen, Pelle Morten Thomas; Jacobsen, Peter

    2012-01-01

    Using simulation as an approach to display and improve internal logistics and handling at hospitals has great potential. This research will show how a simulation model can be used to evaluate changes made to two different cases of transportation of blood samples at a hospital, by evaluating...

  9. The work compatibility improvement framework: an assessment of the worker-work environment interaction in the manufacturing sector.

    Science.gov (United States)

    Genaidy, Ash M; Rinder, Magda M; A-Rehim, Amal D

    2008-08-01

    The manufacturing sector in the US is challenged by high health care costs and shortage of qualified workers, which are largely attributed to the degree of fit between the worker and work environment. In this regard, a healthy worker-work environment interface is a necessary and sufficient condition for the containment of health care costs and the retaining/attraction of highly qualified knowledge workers and should be based on the principles of optimum physical, cognitive and emotional health for the workers. In prior research, the Work Compatibility Improvement Framework (WCIF) was introduced as a vehicle to address these issues and was defined as the identification, improvement and maintenance of the well-being characteristics of the workforce and its interaction with the work environment through the application of engineering, medicine, management and human sciences methodologies, technologies and best practices. This paper advances WCIF by examining its applications in manufacturing with regard to the evaluation of working conditions impacting musculoskeletal/stress outcome measures. A study was conducted in a machining department of a bag packaging manufacturer in the Midwest of the United States. The work tasks were planned and executed with regard to the following aims: (1) to compute work compatibility as a function of work demands and energisers; (2) to establish whether the prevalence of musculoskeletal/stress disorders increases with a decrease in the quality of worker-work environment interface in terms of work compatibility level and other work factors such as shift and job category. A major finding is that a 'poor' work environment (a function of all work domains) results in musculoskeletal/stress disorders that are 105% and 67% higher than those for a 'good' work environment. The evening shift exhibited the poorest compatibility followed by the night shift relative to the day shift. Application of the work compatibility approach demonstrated the

  10. Improved compatibility between polystyrene and poly(vinylidene fluoride) by the addition of urea

    International Nuclear Information System (INIS)

    Melad, O.; Teim, O.A.; Sobeh, E.

    2005-01-01

    The viscosity behavior of dilute urea solution of dimethylformamide (Dmf) of Polystyrene-Poly(vinylidene fluoride) has been studied at 25 degree C. The results show that the polymer mixtures are incompatible in DMF solution in the absence of urea. The influence of urea addition on the degree of compatibility of the polymer mixture has been studied in terms of the compatibility parameters (A6/M, kbm , A [77] ,a and /?) respectively

  11. Incentive Compatibility

    OpenAIRE

    Ledyard, John O.

    1987-01-01

    Incentive compatibility is described and discussed. A summary of the current state of understanding is provided. Key words are: incentive compatibility, game theory, implementation, mechanism, Bayes, Nash, and revelation.

  12. Development of a Supercritical Carbon Dioxide Brayton Cycle: Improving VHTR Efficiency and Testing Material Compatibility - Final Report

    International Nuclear Information System (INIS)

    Chang H. Oh

    2006-01-01

    Generation IV reactors will need to be intrinsically safe, having a proliferation-resistant fuel cycle and several advantages relative to existing light water reactor (LWR). They, however, must still overcome certain technical issues and the cost barrier before it can be built in the U.S. The establishment of a nuclear power cost goal of 3.3 cents/kWh is desirable in order to compete with fossil combined-cycle, gas turbine power generation. This goal requires approximately a 30 percent reduction in power cost for state-of-the-art nuclear plants. It has been demonstrated that this large cost differential can be overcome only by technology improvements that lead to a combination of better efficiency and more compatible reactor materials. The objectives of this research are (1) to develop a supercritical carbon dioxide Brayton cycle in the secondary power conversion side that can be applied to the Very-High-Temperature Gas-Cooled Reactor (VHTR), (2) to improve the plant net efficiency by using the carbon dioxide Brayton cycle, and (3) to test material compatibility at high temperatures and pressures. The reduced volumetric flow rate of carbon dioxide due to higher density compared to helium will reduce compression work, which eventually increase plant net efficiency

  13. Vehicle compatibility in car-to-car collisions : literature review in the framework of the European research project "Improvement of crash compatibility between cars", Workpackage 1.

    NARCIS (Netherlands)

    Sluis, J. van der

    2000-01-01

    In this report, a literature review is given on the subject of crash compatibility and incompatibility between cars. The study is based on scientific publications on this subject published over the last 15 years. The compatibility problem is described from three points of view: statistical,

  14. Subgrouping of A and AB blood groups in Indian blood centres: is it required?

    Science.gov (United States)

    Hazarika, Ranjita; Basu, Sabita; Kaur, Paramjit

    2011-08-01

    Anti A1 antibody in the serum of A2 and A2B individuals is rare but when present can have laboratory and clinical significance. Routine subgrouping of all A and AB blood groups in blood centres in India is difficult due to economic constraints and has always been a point of debate. This study thus brings out the prevalence of anti A1 antibody and the clinical significance related to its presence. The results of the study showed a low prevalence of anti A1 antibody and when present, it had a low thermal amplitude and titre. Further, no blood group discrepancy or problems during compatibility testing were encountered with these (A1 antibody positive) blood units. Thus, it may be concluded that in India and other developing countries where resources are scarce, routine subgrouping of A and AB may not be really worthwhile unless there is a group discrepancy, problem during compatibility testing or history of a transfusion reaction.

  15. [Compatible biomass models of natural spruce (Picea asperata)].

    Science.gov (United States)

    Wang, Jin Chi; Deng, Hua Feng; Huang, Guo Sheng; Wang, Xue Jun; Zhang, Lu

    2017-10-01

    By using nonlinear measurement error method, the compatible tree volume and above ground biomass equations were established based on the volume and biomass data of 150 sampling trees of natural spruce (Picea asperata). Two approaches, controlling directly under total aboveground biomass and controlling jointly from level to level, were used to design the compatible system for the total aboveground biomass and the biomass of four components (stem, bark, branch and foliage), and the total ground biomass could be estimated independently or estimated simultaneously in the system. The results showed that the R 2 of the one variable and bivariate compatible tree volume and aboveground biomass equations were all above 0.85, and the maximum value reached 0.99. The prediction effect of the volume equations could be improved significantly when tree height was included as predictor, while it was not significant in biomass estimation. For the compatible biomass systems, the one variable model based on controlling jointly from level to level was better than the model using controlling directly under total above ground biomass, but the bivariate models of the two methods were similar. Comparing the imitative effects of the one variable and bivariate compatible biomass models, the results showed that the increase of explainable variables could significantly improve the fitness of branch and foliage biomass, but had little effect on other components. Besides, there was almost no difference between the two methods of estimation based on the comparison.

  16. Improving blood transfusion practice by regular education in the United Arab Emirates.

    Science.gov (United States)

    Sajwani, F H

    2012-07-01

    A cross-match to transfused unit ratio of less than 2.0 is frequently used to assess performance in many hospital blood banks. This brief report was initiated to evaluate the practice at a local hospital and to emphasize the importance of regular educational sessions to improve blood transfusion practice. Retrospective data on cross-match : transfused (C : T) ratio of all departments was collected and educational sessions were given to improve practice. Thereafter, a new set of data was collected and change in practice was assessed. Initial data showed total (C : T) ratio of 1.95. After medical staff education, analysis showed clinically significant improvement in blood utilization practice with a (C : T) ratio of 1.60. This brief report indicates the importance of regular physician education, the potential role of blood transfusion committee, and the need to implement clear guidelines for blood transfusion. © 2012 American Association of Blood Banks.

  17. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  18. Compatibility Between Electric Components in Wind Farms

    DEFF Research Database (Denmark)

    Holdyk, Andrzej; Holbøll, Joachim; Arana Aristi, Iván

    2011-01-01

    The paper describes a method for investigation of the compatibility between electric components in wind farms by identifying critical resonances at different points of an offshore wind farm (OWF), based on systematic variation of critical parameters. In this way, the design of future OWF can...... be improved at a very early stage of the process. It is also revealed what parameters are the most important ones when considering compatibility. It was observed that a change of capacitance in the collection grid shifts the resonance peaks. A change in WT transformer capacitances influences the admittance...

  19. On The compatibility and dynamic vulcanization of Pom/Nbr blends

    International Nuclear Information System (INIS)

    Mortezaee, M.; Naveed Family, M.H.; Mehrabzadeh, M.

    2001-01-01

    Polymer blends based on polyacetal butadiene rubber were prepared by melt blending technique. The mixing parameters such ad temperature, time and speed of mixing were varied to obtain a wide range of properties. The mixing parameters were optimized by evaluating the mechanical properties of the blend over a wide range of mixing conditions. The morphology of the blend indicated a two-phase structure. This study describes an attempt to improve the tensile strength of Pom/Nbr blends by means of compatibility and dynamic vulcanization. A commercial compatibility, maleic anhydride (Ma), has been used to control the phase morphology of the blend system. Dicumyl peroxide is used to dynamically vulcanize the Nbr elastomer in the blend. The tensile strength of the compatibility systems showed improvement. Dynamic vulcanization raises elastic recovery and tensile modulus of the blends, but the elongation at break decreases

  20. The role of comprehensive check at the blood bank reception on blood requisitions in detecting potential transfusion errors.

    Science.gov (United States)

    Jain, Ashish; Kumari, Sonam; Marwaha, Neelam; Sharma, Ratti Ram

    2015-06-01

    Pre-transfusion testing includes proper requisitions, compatibility testing and pre-release checks. Proper labelling of samples and blood units and accurate patient details check helps to minimize the risk of errors in transfusion. This study was aimed to identify requisition errors before compatibility testing. The study was conducted in the blood bank of a tertiary care hospital in north India over a period of 3 months. The requisitions were screened at the reception counter and inside the pre-transfusion testing laboratory for errors. This included checking the Central Registration number (C.R. No.) and name of patient on the requisition form and the sample label; appropriateness of sample container and sample label; incomplete requisitions; blood group discrepancy. Out of the 17,148 blood requisitions, 474 (2.76 %) requisition errors were detected before the compatibility testing. There were 192 (1.11 %) requisitions where the C.R. No. on the form and the sample were not tallying and in 70 (0.40 %) requisitions patient's name on the requisition form and the sample were different. Highest number of requisitions errors were observed in those received from the Emergency and Trauma services (27.38 %) followed by Medical wards (15.82 %) and the lowest number (3.16 %) of requisition errors were observed from Hematology and Oncology wards. C.R. No. error was the most common error observed in our study. Thus a careful check of the blood requisitions at the blood bank reception counter helps in identifying the potential transfusion errors.

  1. Improvements of material hemo-compatibility in order to obtain: - antithrombotic surfaces by radio-grafting of sulphonamide groups on fluoro-polymers; - or endothelialisable surfaces by chemical grafting of peptides on a model surface: silica

    International Nuclear Information System (INIS)

    Durrieu-Porte, Marie-Christine

    1998-01-01

    This research thesis addresses the elaboration of hemo-compatible polymer materials for the preparation of new vascular substitutes, notably for an application in the treatment of cardio-vascular diseases. After having recalled and described how a thrombosis can appear at the interface between blood and the substitute under the influence of several mechanism, the author more particularly describes two possible strategies for the struggle against thrombosis by treating its origin rather than its effect. Several substrate materials are considered: PVDF and P(VDF-HFP). They are used as a basis for the formation of a substitute to blood vessels due to their high mechanical strength, their good resistance to radiations, and their good chemical inertia. The author reports the transformation of these materials into a heparin-like material by functionalization of radio-grafted polystyrene. She analyses the physical-chemical and morphological characteristics of both materials before and after different treatments, and then reports studies of hemo-compatibility and cyto-compatibility. In a next part, she reports the study of another treatment aimed at increasing the anti-thrombogenic characteristic of the material. This study has been performed on a model material, silica. The same kind of studies as in the first part are performed, but with applying grafting of peptides [fr

  2. Improved Mechanical Compatibility and Cytocompatibility of Ta/Ti Double-Layered Composite Coating

    Science.gov (United States)

    Ding, Ding; Xie, Youtao; Li, Kai; Huang, Liping; Zheng, Xuebin

    2017-08-01

    In order to improve the mechanical compatibility and cytocompatibility of titanium implants, a composite coating with double layers composed of tantalum and titanium was designed and prepared using plasma spraying technology. In the composite coating, the upper tantalum layer provides a good biocompatibility, and the sublayer of titanium with a porous structure ensures the low elastic modulus. Results show that the fabricated composite coating exhibits a relatively low elastic modulus of 26.7 GPa, which is close to the elastic modulus of human cortical bone. In vitro cytocompatibility evaluation of the composite coating shows that the human bone marrow stromal cells exhibit enhanced adhesion and spreading performance on the double-layered composite coating in comparison with the single-layered titanium coating. In order to eliminate the misgivings of chemical stability of the composite coating in clinical application, electrochemical corrosion of the coating was examined. The results obtained revealed a very weak galvanic corrosion between the tantalum and titanium in the composite coating, which would ensure the safety of the coating in vivo.

  3. Alternative Work Schedules: Designing Compatible Work Systems

    Science.gov (United States)

    Steen, Pamela L.

    1977-01-01

    Attempts to improve the quality of working life through changes in environmental factors, such as flexible hours, are likely to bring limited and short-term advantages unless the work process itself is well-designed and compatible with the environmental changes. (Author/LBH)

  4. Improving Safe Blood Donation in Nigeria: The Roles of the Mass Media

    Science.gov (United States)

    Oriji, Christian Chigozi

    2015-01-01

    The study discusses improving safe blood donation in Nigeria and the roles of the mass media in achieving same in Nigerian hospitals. In this regard, it answers the questions: What is blood? What is blood donation? And is safe blood donation adequate in Nigeria? Beyond the relevant answers given on the above questions, it also explains the roles…

  5. Improving the chemical compatibility of sealing glass for solid oxide fuel cells: Blocking the reactive species by controlled crystallization

    Science.gov (United States)

    Zhang, Teng; Zou, Qi; Zeng, Fanrong; Wang, Shaorong; Tang, Dian; Yang, Hiswen

    2012-10-01

    The chemical compatibility of sealing glass is of great importance for Solid oxide fuel cell (SOFC). In this work, the interfacial reaction between sealing glass and Cr-containing interconnect alloy is characterized by reacting Cr2O3 powders with a representative SrO-containing glass crystallized by different heat-treatment schedules. The crystalline structure and crystalline content of sealing glass are determined by X-ray diffraction. The results show that the fraction of Cr6+ decreases from 39.8 ± 1.9% for quenched glass to 8.2 ± 0.4% for glass crystallized at 900 °C for 2 h. In addition, the interfacial reaction can be further reduced with increasing crystallization temperature and time as well as the addition of nucleation agent (TiO2). The formation of some Sr-containing crystalline phases, Sr2SiO4 and Sr(TiO3), contributes to the improvement of chemical compatibility of sealing glass, in agreement with the results of thermodynamic calculations.

  6. Quality Improvement Methodologies Increase Autologous Blood Product Administration

    Science.gov (United States)

    Hodge, Ashley B.; Preston, Thomas J.; Fitch, Jill A.; Harrison, Sheilah K.; Hersey, Diane K.; Nicol, Kathleen K.; Naguib, Aymen N.; McConnell, Patrick I.; Galantowicz, Mark

    2014-01-01

    Abstract: Whole blood from the heart–lung (bypass) machine may be processed through a cell salvaging device (i.e., cell saver [CS]) and subsequently administered to the patient during cardiac surgery. It was determined at our institution that CS volume was being discarded. A multidisciplinary team consisting of anesthesiologists, perfusionists, intensive care physicians, quality improvement (QI) professionals, and bedside nurses met to determine the challenges surrounding autologous blood delivery in its entirety. A review of cardiac surgery patients’ charts (n = 21) was conducted for analysis of CS waste. After identification of practices that were leading to CS waste, interventions were designed and implemented. Fishbone diagram, key driver diagram, Plan–Do–Study–Act (PDSA) cycles, and data collection forms were used throughout this QI process to track and guide progress regarding CS waste. Of patients under 6 kg (n = 5), 80% had wasted CS blood before interventions, whereas those patients larger than 36 kg (n = 8) had 25% wasted CS before interventions. Seventy-five percent of patients under 6 kg who had wasted CS blood received packed red blood cell transfusions in the cardiothoracic intensive care unit within 24 hours of their operation. After data collection and didactic education sessions (PDSA Cycle I), CS blood volume waste was reduced to 5% in all patients. Identification and analysis of the root cause followed by implementation of education, training, and management of change (PDSA Cycle II) resulted in successful use of 100% of all CS blood volume. PMID:24783313

  7. Coproduction of detergent compatible bacterial enzymes and stain removal evaluation.

    Science.gov (United States)

    Niyonzima, Francois N; More, Sunil S

    2015-10-01

    Most of the detergents that are presently produced contain the detergent compatible enzymes to improve and accelerate the washing performance by removing tough stains. The process is environment friendly as the use of enzymes in the detergent formulation reduces the utilization of toxic detergent constituents. The current trend is to use the detergent compatible enzymes that are active at low and ambient temperature in order to save energy and maintain fabric quality. As the detergent compatible bacterial enzymes are used together in the detergent formulation, it is important to co-produce the detergent enzymes in a single fermentation medium as the enzyme stability is assured, and production cost gets reduced enormously. The review reports on the production, purification, characterization and application of detergent compatible amylases, lipases, and proteases are available. However, there is no specific review or minireview on the concomitant production of detergent compatible amylases, lipases, and proteases. In this minireview, the coproduction of detergent compatible enzymes by bacterial species, enzyme stability towards detergents and detergent components, and stain release analysis were discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Detergent-compatible bacterial amylases.

    Science.gov (United States)

    Niyonzima, Francois N; More, Sunil S

    2014-10-01

    Proteases, lipases, amylases, and cellulases are enzymes used in detergent formulation to improve the detergency. The amylases are specifically supplemented to the detergent to digest starchy stains. Most of the solid and liquid detergents that are currently manufactured contain alkaline enzymes. The advantages of using alkaline enzymes in the detergent formulation are that they aid in removing tough stains and the process is environmentally friendly since they reduce the use of toxic detergent ingredients. Amylases active at low temperature are preferred as the energy consumption gets reduced, and the whole process becomes cost-effective. Most microbial alkaline amylases are used as detergent ingredients. Various reviews report on the production, purification, characterization, and application of amylases in different industry sectors, but there is no specific review on bacterial or fungal alkaline amylases or detergent-compatible amylases. In this mini-review, an overview on the production and property studies of the detergent bacterial amylases is given, and the stability and compatibility of the alkaline bacterial amylases in the presence of the detergents and the detergent components are highlighted.

  9. Viral transfusion transmissible infections amongst blood donors in ...

    African Journals Online (AJOL)

    1 These safety procedures refer to the small preliminary donation made on site. This is firstly cross-matched for compatibility with the intended recipient, if the donor is suitable the blood sample is then screened for the listed infectious agents. It is only those individuals who are clear of infection and compatible with the.

  10. Improving Blood Pressure Control Using Smart Technology.

    Science.gov (United States)

    Ciemins, Elizabeth L; Arora, Anupama; Coombs, Nicholas C; Holloway, Barbara; Mullette, Elizabeth J; Garland, Robin; Walsh Bishop-Green, Shannon; Penso, Jerry; Coon, Patricia J

    2018-03-01

    The authors sought to determine if wireless oscillometric home blood pressure monitoring (HBPM) that integrates with smartphone technology improves blood pressure (BP) control among patients with new or existing uncontrolled hypertension (HTN). A prospective observational cohort study monitored BP control before and after an educational intervention and introduction to HBPM. Patients in the intervention group were instructed to track their BP using a smartphone device three to seven times per week. Cases were matched to controls at a 1:3 allocation ratio on several clinical characteristics over the same period and received usual care. The proportion of patients with controlled BP was compared between groups at pre- and postintervention, ∼9 months later. Results and Materials: The total study population included 484 patients with mean age 60 years (range 23-102 years), 47.7% female, and 84.6% Caucasian. Mean preintervention BP was 137.8 mm Hg systolic and 81.4 mm Hg diastolic. Mean BP control rates improved for patients who received HBPM from 42% to 67% compared with matched control patients who improved from 59% to 67% (p technology has the potential to improve HTN management among patients with uncontrolled or newly diagnosed HTN. Technology needs to be easy to use and operate and would work best when integrated into local electronic health record systems. In systems without this capability, medical assistants or other personnel may be trained to facilitate the process. Nurse navigator involvement was instrumental in bridging communication between the patients and provider.

  11. The framework which aims at improving compatibility of the high-level radioactive waste disposal technology with social values and the role of risk communication

    International Nuclear Information System (INIS)

    Sakamoto, Shuichi; Kanda, Keiji

    2002-01-01

    Public perception on safety is the key factor for achieving public acceptance of the high-level radioactive waste (HLW) disposal program. Past studies on public perception and HLW management have confirmed that the public do not share the confidence of the experts in safety and feasibility of HLW disposal. The importance of a more comprehensive approach to enhance acceptability of the HLW disposal technology is recognized. This paper proposes a framework for inducing the implementers and regulators to improve compatibility of the HLW disposal technology with social values. In this framework, the implementers and regulators identify technical components which are subject to substantial influence from public concerns. Then, they manage these components through the following actions: 1) establishing policies, targets and plans to make these components compatible with social values, 2) developing and utilizing the components based on the above policies, targets and plans, 3) checking the extent of compatibility through intensive risk communication and 4) improving the process of developing and utilizing the components. This framework requires information disclosure and evaluation by an independent body which are expected to intensify the incentive to take the above actions. Canada's environmental assessment review process regarding the HLW disposal concept suggests that this framework could work effectively. (author)

  12. Blood transfusion in preterm infants improves intestinal tissue oxygenation without alteration in blood flow.

    Science.gov (United States)

    Banerjee, J; Leung, T S; Aladangady, N

    2016-11-01

    The objective of the study was to investigate the splanchnic blood flow velocity and oximetry response to blood transfusion in preterm infants according to postnatal age. Preterm infants receiving blood transfusion were recruited to three groups: 1-7 (group 1; n = 20), 8-28 (group 2; n = 21) and ≥29 days of life (group 3; n = 18). Superior mesenteric artery (SMA) peak systolic (PSV) and diastolic velocities were measured 30-60 min pre- and post-transfusion using Doppler ultrasound scan. Splanchnic tissue haemoglobin index (sTHI), tissue oxygenation index (sTOI) and fractional tissue oxygen extraction (sFTOE) were measured from 15-20 min before to post-transfusion using near-infrared spectroscopy. The mean pretransfusion Hb in group 1, 2 and 3 was 11, 10 and 9 g/dl, respectively. The mean (SD) pretransfusion SMA PSV in group 1, 2 and 3 was 0·63 (0·32), 0·81 (0·33) and 0·97 (0·40) m/s, respectively, and this did not change significantly following transfusion. The mean (SD) pretransfusion sTOI in group 1, 2 and 3 was 36·7 (19·3), 44·6 (10·4) and 41·3 (10·4)%, respectively. The sTHI and sTOI increased (P transfusion in all groups. On multivariate analysis, changes in SMA PSV and sTOI following blood transfusion were not associated with PDA, feeding, pretransfusion Hb and mean blood pressure. Pretransfusion baseline splanchnic tissue oximetry and blood flow velocity varied with postnatal age. Blood transfusion improved intestinal tissue oxygenation without altering mesenteric blood flow velocity irrespective of postnatal ages. © 2016 International Society of Blood Transfusion.

  13. 76 FR 23824 - Guidance for Industry: “Computer Crossmatch” (Computerized Analysis of the Compatibility Between...

    Science.gov (United States)

    2011-04-28

    ... Plasma Type)'' dated June 2007. DATES: Submit either electronic or written comments on Agency guidances... the Compatibility Between the Donor's Cell Type and the Recipient's Serum or Plasma Type... Serum or Plasma Type)'' dated April 2011. The guidance document provides blood establishments that...

  14. Hyaluronan Immobilized Polyurethane as a Blood Contacting Material

    Directory of Open Access Journals (Sweden)

    Feirong Gong

    2010-01-01

    Full Text Available Hyaluronan (hyaluronic acid, HA was immobilized onto the surface of amino-functionalized polyurethane films with the goal of obtaining a novel kind of biomaterial which had the potential in blood-contacting applications. The amino-functionalized polyurethane was prepared by synthesized acidic polyurethane whose pendant carboxyl groups were treated with an excess amount of 1,3-diaminopropane in the presence of N,N-carbonyldiimidazole (CDI. Attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR, Raman spectroscopy (RS, scanning electron microscopy (SEM, and water contact angle measurement were used to confirm the surface changes at each step of treatment, both in morphologies and chemical compositions. APTT and PT results showed that HA immobilization could prolong the blood coagulation time, thus HA-immobilized polyurethane (PU-HA exhibited improved blood compatibility. Cytotoxicity analysis showed that the PU-HA films synthesized in this study were cytocompatible and could support human vein endothelial cells (HUVECs adhesion and proliferation.

  15. fMRI-compatible rehabilitation hand device

    Directory of Open Access Journals (Sweden)

    Tzika Aria

    2006-10-01

    Full Text Available Abstract Background Functional magnetic resonance imaging (fMRI has been widely used in studying human brain functions and neurorehabilitation. In order to develop complex and well-controlled fMRI paradigms, interfaces that can precisely control and measure output force and kinematics of the movements in human subjects are needed. Optimized state-of-the-art fMRI methods, combined with magnetic resonance (MR compatible robotic devices for rehabilitation, can assist therapists to quantify, monitor, and improve physical rehabilitation. To achieve this goal, robotic or mechatronic devices with actuators and sensors need to be introduced into an MR environment. The common standard mechanical parts can not be used in MR environment and MR compatibility has been a tough hurdle for device developers. Methods This paper presents the design, fabrication and preliminary testing of a novel, one degree of freedom, MR compatible, computer controlled, variable resistance hand device that may be used in brain MR imaging during hand grip rehabilitation. We named the device MR_CHIROD (Magnetic Resonance Compatible Smart Hand Interfaced Rehabilitation Device. A novel feature of the device is the use of Electro-Rheological Fluids (ERFs to achieve tunable and controllable resistive force generation. ERFs are fluids that experience dramatic changes in rheological properties, such as viscosity or yield stress, in the presence of an electric field. The device consists of four major subsystems: a an ERF based resistive element; b a gearbox; c two handles and d two sensors, one optical encoder and one force sensor, to measure the patient induced motion and force. The smart hand device is designed to resist up to 50% of the maximum level of gripping force of a human hand and be controlled in real time. Results Laboratory tests of the device indicate that it was able to meet its design objective to resist up to approximately 50% of the maximum handgrip force. The detailed

  16. Preparation of enhanced hydrophobic poly(L-lactide-co-ε-caprolactone) films surface and its blood compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Il; Lim, Jin Ik; Jung, Youngmee; Mun, Cho Hay [Division of Life and Health Science, Biomaterials Research Center, Korea Institute of Science and Technology, Seoul (Korea, Republic of); Kim, Ji Heung, E-mail: kimjh@skku.edu [Department of Chemical Engineering, Polymer Technology Institute, Sungkyunkwan University, Suwon, Kyunggi (Korea, Republic of); Kim, Soo Hyun, E-mail: soohkim@kist.re.kr [Division of Life and Health Science, Biomaterials Research Center, Korea Institute of Science and Technology, Seoul (Korea, Republic of); KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul (Korea, Republic of)

    2013-07-01

    Hydrophobicity-enhanced poly(L-lactide-co-ε-caprolactone) (PLCL) (50:50) films were cast by using the solvent–nonsolvent casting method. PLCL (50:50) was synthesized by the well-known random copolymerization process and confirmed by {sup 1}H NMR analysis. The molecular weight of the synthesized PLCL was measured by gel permeation chromatography (GPC). Number-average (Mn), weight-average (Mw) molecular weights and polydispersity (Mw/Mn) were 7 × 10{sup 4}, 1.2 × 10{sup 5}, and 1.7, respectively. PLCL films were cast in vacuum condition with various nonsolvents and nonsolvent ratios. Tetrahydrofuran (THF) was used as the solvent and three different alcohols were used as the nonsolvent: methanol, ethanol, and isopropyl alcohol (IPA). Surface hydrophobicity was confirmed by water contact angle. The water contact angle was increased from 81° ± 2° to 107° ± 2°. Water contact angle was influenced by surface porosity and topography. The prepared film surfaces were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The change of crystalline property was characterized by X-ray diffraction (XRD). Platelet adhesion tests on the modified PLCL film surfaces were evaluated by platelet-rich plasma (PRP). The modified film surface exhibited enhanced hydrophobicity and reduced platelet adhesion ratio depending on the surface topography. One of the candidate products proposed as a potential blood compatible material showed a markedly reduced platelet adhesion property.

  17. Performance improvements of the BNC tubes from unique double-silicone-tube bioreactors by introducing chitosan and heparin for application as small-diameter artificial blood vessels.

    Science.gov (United States)

    Li, Xue; Tang, Jingyu; Bao, Luhan; Chen, Lin; Hong, Feng F

    2017-12-15

    In order to improve property of bacterial nano-cellulose (BNC) to achieve the requirements of clinical application as small caliber vascular grafts, chitosan (CH) was deposited into the fibril network of the BNC tubes fabricated in unique Double-Silicone-Tube bioreactors. Heparin (Hep) was then chemically grafted into the BNC-based tubes using EDC/NHS crosslinking to improve performance of anticoagulation and endothelialization. Physicochemical and mechanical property, blood compatibility, and cytocompatibility were compared before and after compositing. The results indicated that strength at break was increased but burst pressure decreased slightly after compositing. Performance of the BNC tubes was improved remarkably after introducing chitosan and heparin. The EDC/NHS crosslinking catalyzed both amide bonds and ester bonds formation in the BNC/CH-Hep composites. Three-dimensional surface structure and roughness were firstly obtained and discussed in relation to the hemocompatibility of BNC-based tubes. This work demonstrates the heparinized BNC-based tubes have great potential in application as small-diameter vascular prosthesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Veganism Is a Viable Alternative to Conventional Diet Therapy for Improving Blood Lipids and Glycemic Control.

    Science.gov (United States)

    Trepanowski, John F; Varady, Krista A

    2015-01-01

    The American Diabetes Association (ADA) and the National Cholesterol Education Program (NCEP) have each outlined a set of dietary recommendations aimed at improving glycemic control and blood lipids, respectively. However, traditional vegan diets (low-fat diets that proscribe animal product consumption) are also effective at improving glycemic control, and dietary portfolios (vegan diets that contain prescribed amounts of plant sterols, viscous fibers, soy protein, and nuts) are also effective at improving blood lipids. The purpose of this review was to compare the effects of traditional vegan diets and dietary portfolios with ADA and NCEP diets on body weight, blood lipids, blood pressure, and glycemic control. The main findings are that traditional vegan diets appear to improve glycemic control better than ADA diets in individuals with type 2 diabetes mellitus (T2DM), while dietary portfolios have been consistently shown to improve blood lipids better than NCEP diets in hypercholesterolemic individuals.

  19. Clinical evaluation of the endothelial tie-2 crossmatch in ABO compatible and ABO incompatible renal transplants.

    Science.gov (United States)

    Kafetzi, Maria L; Boletis, John N; Melexopoulou, Christine A; Tsakris, Athanassios; Iniotaki, Aliki G; Doxiadis, Ilias I N

    2013-11-01

    The necessity of detection of other than the classical major histocompatibility complex (MHC) and MHC class I-related chain A (MICA) directed antibodies prior to organ transplantation has already been repeatedly reported. A commercial flow cytometric endothelial crossmatch (CM) using isolated peripheral blood tie-2 positive cells provides a tool to detect non-MHC antibodies in addition to antibodies directed to MHC class I and II. The vast majority of circulating tie-2 positive cells expresses HLA-DR but not the A, B blood group antigens. Tie-2 cells are circulating surrogate endothelial cells. In this retrospective study we evaluated the endothelial CM in 51 renal transplantations, 30 with ABO compatible grafts and 21 with ABO incompatible grafts. Fifteen of the ABO compatible recipients (group A) developed unexplained rejection episodes (RE) while the remaining 15 had no RE (group B). Five cases of group A and none of group B had a positive tie-2 CM before transplantation (p=0.042). A positive tie-2 CM was also correlated with graft failure in ABO compatible transplants (p=0.02). No significant correlation was found between a positive pre-transplant tie-2 CM and RE in the ABO incompatible group. This study strongly suggest that a positive tie-2 CM may predict post-transplantation complications in ABO compatible grafts while negative reactions are not predictive. The test is not significantly correlated with RE in ABO incompatible grafts possibly due to applied desensitization. Copyright © 2013 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  20. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  1. Leukocyte and platelet depletion improves blood flow and function in a renal transplant model.

    Science.gov (United States)

    Yates, Phillip J; Hosgood, Sarah A; Nicholson, Michael L

    2012-01-01

    Donation after cardiac death (DCD) donors are an important source of organs for transplantation. Due to warm and cold ischemic injury, DCD kidneys undergo a significant reperfusion insult when transplanted. This is manifested clinically as a high incidence of delayed graft function (DGF) and primary non-function (PNF). The importance of leukocytes in the generation of reperfusion injury is pivotal. Using an ex vivo porcine model of kidney transplantation, the effects of reperfusion with leukocyte and platelet depleted blood (LDB) and whole blood (WB) on renal blood flow and function were compared. Hemodynamic measurements were recorded, and biochemical, hematological, and histologic samples taken at set time-points. Reperfusion with LDB improved renal blood flow significantly compared with WB reperfusion. In addition, there was a significant improvement in creatinine clearance and renal oxygen consumption, but not fractional excretion of sodium, acid-base homeostasis, urinary nitric oxide (NO), or 8-isoprostane levels. This study represents a good model for the initial reperfusion period in renal transplantation. Improvement in only some functional markers and neither urinary NO nor 8-isoprostane levels indicates that improved blood flow alone is not sufficient to reverse the severe ischemic insult endured by DCD kidneys. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Improved thrombogenicity on oxygen etched Ti6Al4V surfaces

    International Nuclear Information System (INIS)

    Riedel, Nicholas A.; Smith, Barbara S.; Williams, John D.; Popat, Ketul C.

    2012-01-01

    Thrombus formation on blood contacting biomaterials continues to be a key factor in initiating a critical mode of failure in implantable devices, requiring immediate attention. In the interest of evaluating a solution for one of the most widely used biomaterials, titanium and its alloys, this study focuses on the use of a novel surface oxidation treatment to improve the blood compatibility. This study examines the possibility of using oblique angle ion etching to produce a high quality oxide layer that enhances blood compatibility on medical grade titanium alloy Ti6Al4V. An X-ray photoelectron spectroscopy (XPS) analysis of these oxygen-rich surfaces confirmed the presence of TiO 2 peaks and also indicated increased surface oxidation as well as a reduction in surface defects. After 2 h of contact with whole human plasma, the oxygen etched substrates demonstrated a reduction in both platelet adhesion and activation as compared to bare titanium substrates. The whole blood clotting behavior was evaluated for up to 45 min, showing a significant decrease in clot formation on oxygen etched substrates. Finally, a bicinchoninic acid (BCA) total protein assay and XPS were used to evaluate the degree of key blood serum protein (fibrinogen, albumin, immunoglobulin G) adsorption on the substrates. The results showed similar protein levels for both the oxygen etched and control substrates. These results indicate that oblique angle oxygen etching may be a promising method to increase the thrombogenicity of Ti6Al4V. - Highlights: ►Oblique angle oxygen ion etching creates a high quality, uniform oxide surface. ►Oxygen etched substrates showed fewer adhered platelets. ►Platelet activation was reduced by the improved oxide surface. ►Oxygen etched substrates exhibited increased whole blood clotting times. ►Although clotting reductions were seen, protein adsorption remained similar.

  3. Interactive virtual mock-ups for Remote Handling compatibility assessment of heavy components

    Energy Technology Data Exchange (ETDEWEB)

    Oosterhout, J. van, E-mail: j.vanoosterhout@differ.nl [FOM Institute DIFFER (Dutch Institute for Fundamental Energy Research), Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M.; Koning, J.F. [Heemskerk Innovative Technology B.V., Jonckerweg 12, 2201 DZ Noordwijk 6 (Netherlands); Ronden, D.M.S.; Baar, M. de [FOM Institute DIFFER (Dutch Institute for Fundamental Energy Research), Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands)

    2014-10-15

    Highlights: •Specific ITER components require RHCA on hardware mock-ups. •Hardware mock-ups are expensive and have a long lead time. •Interactive Virtual Reality mock-ups are readily available and easily adapted. •This paper analysis and proposes improvements to simulator capabilities. -- Abstract: ITER standards Tesini (2009) require hardware mock-ups to validate the Remote Handling (RH) compatibility of RH class 1- and critical class 2-components. Full-scale mock-ups of large ITER components are expensive, have a long lead time and lose their relevance in case of design changes. Interactive Virtual Reality simulations with real time rigid body dynamics and contact interaction allow for RH Compatibility Assessment during the design iterations. This paper explores the use of interactive virtual mock-ups to analyze the RH compatibility of heavy component handling and maintenance. It infers generic maintenance operations from the analysis and proposes improvements to the simulator capabilities.

  4. Interactive virtual mock-ups for Remote Handling compatibility assessment of heavy components

    International Nuclear Information System (INIS)

    Oosterhout, J. van; Heemskerk, C.J.M.; Koning, J.F.; Ronden, D.M.S.; Baar, M. de

    2014-01-01

    Highlights: •Specific ITER components require RHCA on hardware mock-ups. •Hardware mock-ups are expensive and have a long lead time. •Interactive Virtual Reality mock-ups are readily available and easily adapted. •This paper analysis and proposes improvements to simulator capabilities. -- Abstract: ITER standards Tesini (2009) require hardware mock-ups to validate the Remote Handling (RH) compatibility of RH class 1- and critical class 2-components. Full-scale mock-ups of large ITER components are expensive, have a long lead time and lose their relevance in case of design changes. Interactive Virtual Reality simulations with real time rigid body dynamics and contact interaction allow for RH Compatibility Assessment during the design iterations. This paper explores the use of interactive virtual mock-ups to analyze the RH compatibility of heavy component handling and maintenance. It infers generic maintenance operations from the analysis and proposes improvements to the simulator capabilities

  5. Improved isolation protocol for equine cord blood-derived mesenchymal stromal cells

    DEFF Research Database (Denmark)

    Koch, Thomas Gadegaard; Thomsen, Preben Dybdahl; Betts, Dean H.

    2009-01-01

      BACKGROUND AIMS: A robust methodology for the isolation of cord blood-derived multipotent mesenchymal stromal cells (CB-MSCs) from fresh umbilical cord blood has not been reported in any species. The objective of this study was to improve the isolation procedure for equine CB-MSCs. METHODS: Pre......-culture separation of red and white blood cells was done using either PrepaCyte?-EQ medium or Ficoll-Paque? PREMIUM density medium. Regular FBS and MSC-qualified FBS were compared for their ability to support the establishment of putative primary MSC colonies. RESULTS AND CONCLUSIONS: Our results indicate that Prepa...

  6. Red blood cell alloimmunization in sickle cell disease patients in ...

    African Journals Online (AJOL)

    Objective: Alloimmunization is a recognized complication of red blood cell (RBC) transfusion and causes delayed hemolytic transfusion reactions and provides problems sourcing compatible blood for future transfusions. The objective of this study was to determine the frequency of RBC alloimmunization in SCD patients in ...

  7. An MRI-compatible hand sensory vibrotactile system

    International Nuclear Information System (INIS)

    Wang, Fa; Lakshminarayanan, Kishor; Slota, Gregory P; Seo, Na Jin; Webster, John G

    2015-01-01

    Recently, the application of vibrotactile noise to the wrist or back of the hand has been shown to enhance fingertip tactile sensory perception (Enders et al 2013), supporting the potential for an assistive device worn at the wrist, that generates minute vibrations to help the elderly or patients with sensory deficit. However, knowledge regarding the detailed physiological mechanism behind this sensory improvement in the central nervous system, especially in the human brain, is limited, hindering progress in development and use of such assistive devices. To enable investigation of the impact of vibrotactile noise on sensorimotor brain activity in humans, a magnetic resonance imaging (MRI)-compatible vibrotactile system was developed to provide vibrotactile noise during an MRI of the brain. The vibrotactile system utilizes a remote (outside the MR room) signal amplifier which provides a voltage from –40 to +40 V to drive a 12 mm diameter piezoelectric vibrator (inside the MR room). It is portable and is found to be MRI-compatible which enables its use for neurologic investigation with MRI. The system was also found to induce an improvement in fingertip tactile sensation, consistent with the previous study. (note)

  8. A research project to encourage system-compatible design of end-use appliances

    International Nuclear Information System (INIS)

    Dorr, D.; Key, T.; Sitzlar, G.

    1995-01-01

    Cooperative system compatibility research sponsored by the Canadian Electrical Association (CEA) and the Electric Power Research Institute (EPRI) for improving appliance performance deficiencies was described. Power producer and end-user compatibility concerns was addressed through the development of a System Compatibility Research Project. A list of project tasks was provided. The CEA and EPRI initiated a project to establish flicker response of various lighting systems, which included physical tests. Results of this project were presented and discussed. The incentives for developing switch mode power supplies with enhanced immunity to voltage fluctuations and short interruptions was discussed. It was concluded that power quality studies currently underway will provide designers with a profile of the expected utility environment for their products. System compatibility research will identify areas that should be addressed by standards bodies so that designers can apply applicable criteria objectives early in the appliance design process. These efforts were expected to encourage appropriate manufacturer criteria for compatibility by convincing buyers and sellers that there is a real pay back for this investment. 13 refs., 6 figs., 4 tabs

  9. The ITER EC H and CD upper launcher: Analysis of remote handling compatibility

    International Nuclear Information System (INIS)

    Ronden, D.M.S.; Baar, M. de; Chavan, R.; Elzendoorn, B.S.Q.; Goodman, T.; Heemskerk, C.J.M.; Henderson, M.A.; Koning, J.F.; Saibene, G.; Spaeh, P.; Strauss, D.

    2011-01-01

    Research highlights: → RH class 1 requires a full RH compatible design and a detailed maintenance plan that needs to be demonstrated through hardware mockup testing. → RH class 2 requires a full RH compatible design and a detailed and verified maintenance plan. → RH class 3 requires a RH compatible design and a basic maintenance plan. - Abstract: The present design of the ECH (Electron Cyclotron Heating) upper port launcher has been evaluated in light of the ITER remote handling (RH) requirements. Changes to the launcher design associated with the accessibility, maintainability and manageability of replaceable components are presented. Captive bolts were placed along the flange of the Blanket Shielding Module (BSM). A hinge mechanism was integrated to simplify the (dis-)mounting of the BSM and a frame with incorporated cooling and actuation lines was suggested for simplified mounting and replacement of the steerable mirrors. Rotating the upper port plug upside-down improves maintenance access and component handling. Tools are proposed for manipulation of the port plug and its sub-components. The RH compatibility analysis can improve a design. Early consideration of RH requirements and implementation of necessary features is therefore vital.

  10. Cross matching of blood in carcharhiniform, lamniform, and orectolobiform sharks.

    Science.gov (United States)

    Hadfield, Catherine A; Haines, Ashley N; Clayton, Leigh A; Whitaker, Brent R

    2010-09-01

    The transfusion of whole blood in elasmobranchs could provide cardiovascular support following hemorrhage. Since donor and recipient compatibility is not known, a technique was established to allow cross matching of red blood cells and serum in sharks. Cross matching was carried out among 19 individuals from seven species: the nurse shark (Ginglymostoma cirratum), sandbar shark (Carcharhinus plumbeus), sandtiger shark (Carcharias taurus), white-spotted bamboo shark (Chiloscyllium plagiosum), brown-banded bamboo shark (Chiloscyllium punctatum), zebra shark (Stegostoma fasciatum), and spotted wobbegong (Orectolobus maculatus). Negative cross-matches showed no agglutination or hemolysis, suggesting that donor and recipient would be compatible. Cross-matches between conspecifics were all negative (sandbar, sandtiger, nurse, and white-spotted bamboo sharks). All cross-matches between sandbar and sandtiger sharks were also negative. Positive crossmatches consisted of agglutination or hemolysis of red blood cells, suggesting that the donor and recipient would be incompatible. Strong positive reactions occurred, for example, with red blood cells from sandtiger and sandbar sharks and serum from nurse sharks. Cross matching should be carried out in elasmobranchs prior to any blood transfusion.

  11. [Application of multiplex PCR for the screening of genotyping system for the rare blood groups Fy(a-), s-,k-,Di(b-) and Js(b-)].

    Science.gov (United States)

    Jiao, Wei; Xie, Li; Li, Hailan; Lan, Jiao; Mo, Zhuning; Yang, Ziji; Liu, Fei; Xiao, Ruiping; He, Yunlei; Ye, Luyi; Zhu, Ziyan

    2014-04-01

    To screen rare blood groups Fy(a-), s-, k-, Di(b-) and Js(b-) in an ethnic Zhuang population. Sequence-specific primers were designed based on single nucleotide polymorphism (SNP) sites of blood group antigens Fy(b) and s. A specific multiplex PCR system I was established. Multiplex PCR system II was applied to detect alleles antigens Di(b), k, Js(b)1910 and Js(b) 2019 at the same time. The two systems was were used to screen for rare blood group antigens in 4490 randomly selected healthy donors of Guangxi Zhuang ethnic origin. We successfully made the multiplex PCR system I. We detected the rare blood group antigens using the two PCR system. There are five Fy(a-), three s(-), two Di(b-) in 4490 Guangxi zhuang random samples. The multiplex PCR system I has achieved good accuracy and stability. With multiplex PCR systems I and II, 4490 samples were screened. Five Fy(a-), three s(-) and two Di(b-) samples were discovered. Multiplex PCR is an effective methods, which can be used for high throughput screening of rare blood groups. The rare blood types of Guangxi Zhuang ethnic origin obtained through the screening can provide valuable information for compatible blood transfusion. Through screening we obtained precious rare blood type materials which can be used to improve the capability of compatible infusion and reduce the transfusion reactions.

  12. FREQUENCY OF BLOOD GROUPS AND TITERS OF ALLOANTIBODIES IN DOMESTIC CATS

    OpenAIRE

    Anderson Barros Teixeira Pinto; Miguel Angelo da Silva Medeiros; Mariana Palha de Brito Jardim; Antonio Peixoto Albernaz

    2016-01-01

    Hemotherapy requires reliable blood compatibility tests, such as blood typing, to avoid possible transfusion reactions in cats. However, it is also important to avoid neonatal isoerythrolysis. When blood transfusions are performed between incompatible feline donors and recipients, they may develop acute transfusion reactions, especially severe when type A blood is transfused into a type B cat because it has high levels of anti-A alloantibodies. Therefore, knowing on the blood type frequency i...

  13. Chitosan-glycerol phosphate/blood implants improve hyaline cartilage repair in ovine microfracture defects.

    Science.gov (United States)

    Hoemann, Caroline D; Hurtig, Mark; Rossomacha, Evgeny; Sun, Jun; Chevrier, Anik; Shive, Matthew S; Buschmann, Michael D

    2005-12-01

    Microfracture is a surgical procedure that is used to treat focal articular cartilage defects. Although joint function improves following microfracture, the procedure elicits incomplete repair. As blood clot formation in the microfracture defect is an essential initiating event in microfracture therapy, we hypothesized that the repair would be improved if the microfracture defect were filled with a blood clot that was stabilized by the incorporation of a thrombogenic and adhesive polymer, specifically, chitosan. The objectives of the present study were to evaluate (1) blood clot adhesion in fresh microfracture defects and (2) the quality of the repair, at six months postoperatively, of microfracture defects that had been treated with or without chitosan-glycerol phosphate/blood clot implants, using a sheep model. In eighteen sheep, two 1-cm2 full-thickness chondral defects were created in the distal part of the femur and treated with microfracture; one defect was made in the medial femoral condyle, and the other defect was made in the trochlea. In four sheep, microfracture defects were created bilaterally; the microfracture defects in one knee received no further treatment, and the microfracture defects in the contralateral knee were filled with chitosan-glycerol phosphate/autologous whole blood and the implants were allowed to solidify. Fresh defects in these four sheep were collected at one hour postoperatively to compare the retention of the chitosan-glycerol phosphate/blood clot with that of the normal clot and to define the histologic characteristics of these fresh defects. In the other fourteen sheep, microfracture defects were made in only one knee and either were left untreated (control group; six sheep) or were treated with chitosan-glycerol phosphate/blood implant (treatment group; eight sheep), and the quality of repair was assessed histologically, histomorphometrically, and biochemically at six months postoperatively. In the defects that were examined

  14. Improving health profile of blood donors as a consequence of transfusion safety efforts

    DEFF Research Database (Denmark)

    Edgren, Gustaf; Tran, Trung Nam; Hjalgrim, Henrik

    2007-01-01

    BACKGROUND: Transfusion safety rests heavily on the health of blood donors. Although they are perceived as being healthier than average, little is known about their long-term disease patterns and to which extent the blood banks' continuous efforts to optimize donor selection has resulted...... in improvements. Mortality and cancer incidence among blood donors in Sweden and Denmark was investigated. STUDY DESIGN AND METHODS: All computerized blood bank databases were compiled into one database, which was linked to national population and health data registers. With a retrospective cohort study design, 1......,110,329 blood donors were followed for up to 35 years from first computer-registered blood donation to death, emigration, or December 31, 2002. Standardized mortality and incidence ratios expressed relative risk of death and cancer comparing blood donors to the general population. RESULTS: Blood donors had...

  15. Generalized fixed point theorems for compatible mappings with some types in fuzzy metric spaces

    International Nuclear Information System (INIS)

    Cho, Yeol Je; Sedghi, Shaban; Shobe, Nabi

    2009-01-01

    In this paper, we give some new definitions of compatible mappings of types (I) and (II) in fuzzy metric spaces and prove some common fixed point theorems for four mappings under the condition of compatible mappings of types (I) and (II) in complete fuzzy metric spaces. Our results extend, generalize and improve the corresponding results given by many authors.

  16. Improving appropriateness of blood utilization through prospective review of requests for blood products: the role of pathology residents as consultants.

    Science.gov (United States)

    Haldiman, Lindsey; Zia, Hamid; Singh, Gurmukh

    2014-01-01

    To evaluate the effectiveness of prospective review of orders for fresh-frozen plasma (FFP) and platelets in reducing blood-product use, and of the effectiveness of preparing pathology residents to serve as clinical consultants. At our 572-bed tertiary-care hospital, we developed guidelines for the use of blood products in collaboration with a variety of departments. For patients whose condition(s) met generally accepted criteria, we identified trigger points to allow for quick release by blood bank staff of blood products. For patients whose condition(s) did not meet the applicable criteria, the on-call pathology resident reviewed the medical record of that patient to determine whether there were any extenuating circumstances; consulted with the ordering physician and attending pathologist, as needed; and advised the house staff on appropriate use of blood products. We evaluated the change in use of blood products between the years 2009 and 2012 to assess the effectiveness of the program. We observed a decrease of 38.8% and 31.4% in the use of FFP and platelets, respectively (29.7% and 21.1%, respectively, when normalized for the number of discharges). If projected to the national level, this improvement would translate to an annual cost reduction of approximately $130 million. Prospective review of orders for blood products can significantly improve use of these products, thereby reducing risk to patients and avoiding unnecessary healthcare costs. The involvement of pathology residents in the prospective review process provides an excellent opportunity for their training as laboratory consultants. Copyright© by the American Society for Clinical Pathology (ASCP).

  17. The compatibility approach in the classical theory of thermoelectricity seen from the perspective of variational calculus

    Energy Technology Data Exchange (ETDEWEB)

    Seifert, Wolfgang [Institute of Physics, Martin Luther University, Halle-Wittenberg (Germany); Zabrocki, Knud; Mueller, Eckhard [Institute of Materials Research, German Aerospace Center (DLR), 51170 Koeln (Germany); Snyder, G.J. [California Institute of Technology, Pasadena, California 91125 (United States)

    2010-03-15

    The compatibility approach introduced by Snyder and Ursell opens a new pathway for the improvement of thermoelectric (TE) device performance. It has been shown that sufficient compatibility is - besides an increase of the averaged figure of merit Z - essential for efficient operation of a TE device, and that compatibility will facilitate rational materials selection, device design, and the engineering of functionally graded materials (FGMs). In this paper, the authors give an overview of the fundamental results and present a new approach from the perspective of variational calculus. A particular focus is on the role of ideal self-compatibility, i.e., adjusting compatibility locally at any position along a TE leg. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  18. Interaction of blood with radiation-grafted materials

    International Nuclear Information System (INIS)

    Ikada, Y.; Suzuki, M.; Taniguchi, M.; Iwata, H.; Taki, W.; Miyake, H.; Yonekawa, Y.; Handa, H.

    1981-01-01

    Extensive works on blood compatibility of polymeric materials have revealed that it is strongly governed by their surface structure and properties. Among them are roughness, hydrophobic-hydrophilic balance, ionic species, and water content in the surface layer. In the present work, low and high density polyethylenes as well as heat-treated poly(vinyl) alcohol are grafted with acrylamide (and acrylic acid for comparison) by a pre-irradiation technique to convert the rigid hydrophobic surface into a soft hydrogel with high water contents. The surface modification of materials with grafted polyacrylamide chains will be confirmed from the contact angle measurement which is one of the best methods for assessing the hydrophilicity of surfaces. Blood compatibility of the resulting surfaces will be evaluated from in vivo experiments by anastomosing the surface-grafted tubes of small diameter with the carotid artery of rat. (author)

  19. Blood transfusion improves renal oxygenation and renal function in sepsis-induced acute kidney injury in rats.

    Science.gov (United States)

    Zafrani, Lara; Ergin, Bulent; Kapucu, Aysegul; Ince, Can

    2016-12-20

    The effects of blood transfusion on renal microcirculation during sepsis are unknown. This study aimed to investigate the effect of blood transfusion on renal microvascular oxygenation and renal function during sepsis-induced acute kidney injury. Twenty-seven Wistar albino rats were randomized into four groups: a sham group (n = 6), a lipopolysaccharide (LPS) group (n = 7), a LPS group that received fluid resuscitation (n = 7), and a LPS group that received blood transfusion (n = 7). The mean arterial blood pressure, renal blood flow, and renal microvascular oxygenation within the kidney cortex were recorded. Acute kidney injury was assessed using the serum creatinine levels, metabolic cost, and histopathological lesions. Nitrosative stress (expression of endothelial (eNOS) and inducible nitric oxide synthase (iNOS)) within the kidney was assessed by immunohistochemistry. Hemoglobin levels, pH, serum lactate levels, and liver enzymes were measured. Fluid resuscitation and blood transfusion both significantly improved the mean arterial pressure and renal blood flow after LPS infusion. Renal microvascular oxygenation, serum creatinine levels, and tubular damage significantly improved in the LPS group that received blood transfusion compared to the group that received fluids. Moreover, the renal expression of eNOS was markedly suppressed under endotoxin challenge. Blood transfusion, but not fluid resuscitation, was able to restore the renal expression of eNOS. However, there were no significant differences in lactic acidosis or liver function between the two groups. Blood transfusion significantly improved renal function in endotoxemic rats. The specific beneficial effect of blood transfusion on the kidney could have been mediated in part by the improvements in renal microvascular oxygenation and sepsis-induced endothelial dysfunction via the restoration of eNOS expression within the kidney.

  20. Adaptive transmission based on multi-relay selection and rate-compatible LDPC codes

    Science.gov (United States)

    Su, Hualing; He, Yucheng; Zhou, Lin

    2017-08-01

    In order to adapt to the dynamical changeable channel condition and improve the transmissive reliability of the system, a cooperation system of rate-compatible low density parity check (RC-LDPC) codes combining with multi-relay selection protocol is proposed. In traditional relay selection protocol, only the channel state information (CSI) of source-relay and the CSI of relay-destination has been considered. The multi-relay selection protocol proposed by this paper takes the CSI between relays into extra account in order to obtain more chances of collabration. Additionally, the idea of hybrid automatic request retransmission (HARQ) and rate-compatible are introduced. Simulation results show that the transmissive reliability of the system can be significantly improved by the proposed protocol.

  1. Improvement of retinal blood vessel detection by spur removal and Gaussian matched filtering compensation

    Science.gov (United States)

    Xiao, Di; Vignarajan, Janardhan; An, Dong; Tay-Kearney, Mei-Ling; Kanagasingam, Yogi

    2016-03-01

    Retinal photography is a non-invasive and well-accepted clinical diagnosis of ocular diseases. Qualitative and quantitative assessment of retinal images is crucial in ocular diseases related clinical application. In this paper, we proposed approaches for improving the quality of blood vessel detection based on our initial blood vessel detection methods. A blood vessel spur pruning method has been developed for removing the blood vessel spurs both on vessel medial lines and binary vessel masks, which are caused by artifacts and side-effect of Gaussian matched vessel enhancement. A Gaussian matched filtering compensation method has been developed for removing incorrect vessel branches in the areas of low illumination. The proposed approaches were applied and tested on the color fundus images from one publicly available database and our diabetic retinopathy screening dataset. A preliminary result has demonstrated the robustness and good performance of the proposed approaches and their potential application for improving retinal blood vessel detection.

  2. Risk of red blood cell alloimmunisation in Rwanda: Assessment of ...

    African Journals Online (AJOL)

    Background: Screening of alloantibodies in patients is not yet done in district hospitals of Rwanda. The practice is to transfuse ABO/D compatible blood following an immediate spin crossmatch (IS-XM) or indirect antiglobulin test crossmatch (IAT-XM). Objectives: To assess the risk of red blood cell (RBC) alloimmunisation ...

  3. Mirror neuron activation as a function of explicit learning: changes in mu-event-related power after learning novel responses to ideomotor compatible, partially compatible, and non-compatible stimuli.

    Science.gov (United States)

    Behmer, Lawrence P; Fournier, Lisa R

    2016-11-01

    Questions regarding the malleability of the mirror neuron system (MNS) continue to be debated. MNS activation has been reported when people observe another person performing biological goal-directed behaviors, such as grasping a cup. These findings support the importance of mapping goal-directed biological behavior onto one's motor repertoire as a means of understanding the actions of others. Still, other evidence supports the Associative Sequence Learning (ASL) model which predicts that the MNS responds to a variety of stimuli after sensorimotor learning, not simply biological behavior. MNS activity develops as a consequence of developing stimulus-response associations between a stimulus and its motor outcome. Findings from the ideomotor literature indicate that stimuli that are more ideomotor compatible with a response are accompanied by an increase in response activation compared to less compatible stimuli; however, non-compatible stimuli robustly activate a constituent response after sensorimotor learning. Here, we measured changes in the mu-rhythm, an EEG marker thought to index MNS activity, predicting that stimuli that differ along dimensions of ideomotor compatibility should show changes in mirror neuron activation as participants learn the respective stimulus-response associations. We observed robust mu-suppression for ideomotor-compatible hand actions and partially compatible dot animations prior to learning; however, compatible stimuli showed greater mu-suppression than partially or non-compatible stimuli after explicit learning. Additionally, non-compatible abstract stimuli exceeded baseline only after participants explicitly learned the motor responses associated with the stimuli. We conclude that the empirical differences between the biological and ASL accounts of the MNS can be explained by Ideomotor Theory. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  4. Cure of beta-thalassaemia major by umbilical cord blood transplantation--a case report of Malaysia's first cord blood transplantation.

    Science.gov (United States)

    Chan, L L; Lin, H P

    1999-08-01

    A 25-month-old boy with beta-thalassaemia major was presented with an opportunity for umbilical cord blood transplantation when his unborn sibling was diagnosed in utero to be a beta-thalassaemia carrier and also human leucocyte antigen compatible. A barely adequate amount of cord blood was collected at the birth of his sibling and infused into the patient after appropriate chemo-conditioning. Engraftment occurred without major complications. The subject is now alive and well 9 months post-transplant, thus marking our first success in umbilical cord blood transplantation.

  5. Role of value compatibility in IT adoption

    DEFF Research Database (Denmark)

    Bunker, Deborah; Kautz, Karlheinz; Nguyen, Anne Luu Thanh

    2007-01-01

    Compatibility has been recognised as an important element in the adoption of IT innovations in organisations but as a concept it has been generally limited to technical or functional factors. Compatibility is also significant, however, with regard to value compatibility between the organisation......, and the adopted IT innovation. We propose a framework to determine value compatibility analysing the organisation's and information system's structure, practices and culture, and explore the value compatibility of an organisation with its adopted self-service computer-based information system. A case study......-service acceptance and training issues experienced by the case organisation. These findings add insight into the problems experienced with value compatibility and the adoption of the information systems, and show the potential use of the proposed framework in the detection of such problems.Journal of Information...

  6. Plasma fractionation, a useful means to improve national transfusion system and blood safety: Iran experience.

    Science.gov (United States)

    Cheraghali, A M; Abolghasemi, H

    2009-03-01

    In 1974, the government of Iran established Iranian Blood Transfusion Organization (IBTO) as national and centralized transfusion system. Since then donations of blood may not be remunerated and therapy with blood and its components are free of charges for all Iranian patients. Donations are meticulously screened through interviewing donors and lab testing the donations using serological methods. Currently, Iranian donors donate 1735 00 units of blood annually (donation index: 25/1000 population). Implementation of a highly efficient donor selection programme, including donors interview, establishment of confidential unit exclusion programme and laboratory screening of donated bloods by IBTO have led to seroprevalence rates of 0.41%, 0.12% and 0.004% for HBV, HCV and HIV in donated bloods respectively. Since 2004, IBTO has initiated a programme to enter into a contract fractionation agreement for the surplus of recovered plasma produced in its blood collecting centres. Although IBTO has used this project as a mean to improve national transfusion system through upgrading its quality assurance systems, IBTO fractionation project has played a major role in improving availability of plasma-derived medicines in Iran. During 2006-2007, this project furnished the Iran market with 44% and 14% of its needs to the intravenous immunoglobulin and albumin, respectively. Iranian experience showed that contract fractionation of plasma in countries with organized centralized transfusion system, which lack national plasma fractionation facility, in addition to substantial saving on national health resource and enhancing availability of plasma-derived medicines, could serve as a useful means to improve national blood safety profile.

  7. Compatibility of polyamide 6.6 and low density polyethylene polymeric blend using electron beam ionizing radiation

    International Nuclear Information System (INIS)

    Feitosa, Marcos Antonio Fernandes

    2008-01-01

    The plastic industry has recognized that mixture of polymers, called polymeric blends, yields new materials with improve properties and better features of those of the polymer blended. In most of the cases, blends are formed by immiscible components presenting separated phases, micro-structures or morphologies. One of the main factors for good mechanical performance is the interfacial adhesion of the blend components. The improvement of miscibility between the polymer components and the enhancement of blend performance is denominated of compatibility. This compatibility can be achieved by chemical methods or using ionizing radiation. The present work has as a main objective the study of the effect of the ionizing radiation from electron beam in the compatibility of the polyamide (PA) 6.6 and low density polyethylene (LDPE) 75%/25% wt blend, in the range of applied doses from 50 to 250 kGy. The compatibility effect was evaluated by mechanical test, which has shown improvement in the tensile strength and hardness properties and a reduction of the impact resistant. This mechanical behavior can be considered as a combination effect of the cross-linking, induced in the molecular structure on the polymers, and the increase of the miscibility of the blend components. The degree of compatibility was evaluated by the behavior of the glass transition temperatures (T g ) for the blend components obtained by dynamic mechanical analysis (DMA) measurements. The results have shown that the values of T g for PA 6.6 and LDPE get near by 8 deg C showing that the ionizing radiation have promoted a compatibility effect on the irradiated blend. (author)

  8. Interfacial compatibility of polymer-based structures in electronics

    OpenAIRE

    Turunen, Markus P. K.

    2004-01-01

    Interfacial compatibility of dissimilar materials was investigated to achieve a better understanding of interfacial adhesion in metal/polymer/metal systems. Surface modifications of polymers were applied to improve the adhesion. The modified surfaces were characterised by scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and contact angle measurements accompanied by surface free energy evaluations. The pull-off test was employed to asses...

  9. BLOOD COMPATIBILITY OF 2 DIFFERENT TYPES OF MEMBRANE-OXYGENATOR DURING CARDIOPULMONARY BYPASS IN INFANTS

    NARCIS (Netherlands)

    GU, YJ; BOONSTRA, PW; AKKERMAN, C; MUNGROOP, H; TIGCHELAAR, [No Value; VANOEVEREN, W

    1994-01-01

    The contact of blood with the artificial extracorporeal circuit causes a systemic inflammatory response due to blood activation. In this study, we compared two different paediatric membrane oxygenators used for extracorporeal circulation: a hollow fibre membrane oxygenator (Dideco Masterflo D-701,

  10. [Compatibility of Work and Family Life of Employees in the Healthcare Sector: An Issue in Health Services Research].

    Science.gov (United States)

    Lukasczik, Matthias; Ahnert, Jutta; Ströbl, Veronika; Vogel, Heiner; Donath, Carolin; Enger, Ilka; Gräßel, Elmar; Heyelmann, Lena; Lux, Heidemarie; Maurer, Jochen; Özbe, Dominik; Spieckenbaum, Stefanie; Voigtländer, Elzbieta; Wildner, Manfred; Zapf, Andreas; Zellner, Angela; Hollederer, Alfons

    2017-05-18

    Background Healthcare professionals are confronted with specific work-related demands that influence work-family relations and might indirectly affect the quality of healthcare. This paper seeks to provide an overview of the current state of research on this topic of relevance to health services research. The overview may serve as a starting point for modifying structures in the healthcare system (especially in rural regions) with the aim of improving work-family compatibility. Methods A systematic national and international literature search was conducted in terms of a scoping review. The following criteria/contents to be covered in publications were defined: work-family compatibility; work-family interface and work-family conflict in employees working in healthcare; healthcare professions in rural areas and links with work-family issues; interventions to improve work-family compatibility. 145 publications were included in the overview. Results The available literature focuses on physicians and nursing staff while publications on other professions are largely lacking. The methodological quality of existing studies is mostly low, including a lack of meta-analyses. Several studies document dissatisfaction in physicians and nursing staff regarding reconciliation of work and family life. Only few intervention studies were found that seek to improve work-life compatibility; few of them focus on employees in healthcare. There are also deficits with respect to linking work-family issues with aspects of healthcare in rural areas. Conclusions There is a shortage of systematic national and international research regarding work-family compatibility, especially when it comes to the evaluation of interventions. The overview provides starting points for improving work-family compatibility in healthcare. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Assessment of DUPIC fuel compatibility with CANDU-6

    Energy Technology Data Exchange (ETDEWEB)

    Choi, H B; Roh, G H; Jeong, C J; Rhee, B W; Choi, J W [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-07-01

    The compatibility of DUPIC fuel with the existing CANDU reactor was assessed. The technical issues of DUPIC fuel compatibility were chosen based on the CANDU physics design requirements and inherent characteristics of DUPIC fuel. The compatibility was assessed for the reference DUPIC fuel composition which was determined to reduce the composition heterogeneity and improve the spent PWR fuel utilization. Preliminary studies on a CANDU core loaded with DUPIC fuel have shown that the nominal power distribution is flatter than that of a natural uranium core when a 2-bundle shift refueling scheme is used, which reduces the reactivity worths of devices in the core and, therefore, the performance of reactivity devices was assessed. The safety of the core was assessed by a LOCA simulation and it was found that the power pulse upon LOCA can be maintained below that in the natural uranium core when a poison material is used in the DUPIC fuel. For the feasibility of handling DUPIC fuel in the plant, it will be necessary to introduce new equipment to load the DUPIC fuel in the refueling magazine. The radiation effect of DUPIC fuel on both the reactor hardware and the environment will require a quantitative analysis later. (author).

  12. Socio-compatible energy policies

    International Nuclear Information System (INIS)

    Renn, O.; Albrecht, G.; Kotte, U.; Peters, H.P.; Stegelmann, H.U.

    1985-01-01

    The socio-compatibility project comprises three central analytical elements: 1) The arborescent value analysis: Eminent social groups (such as the trade-unions or the ecological institutes) were questioned on their values and criteria applied to evaluate different energy systems. 2) The energy system and scenario impact analysis: Indicators deduced from the arborescent value analysis serve to approximately cover the value dimensions affected by above criteria. 3) Impact analysis weighing executed by a group of arbitrarily chosen citizens. All reflections considered, it is evident that none of the energy policies discussed may claim the title 'socio-compatible'. The individual, i.e. neither scientist nor politician, cannot decide upon the socio-compatibility of one or the other concept. An altogether socially compatible solution accepted and classified as such by different social groups may only crystallize and be set against different options by the political formation of opinion. The studys' primary concern lies in furnishing information, i.e. aids for politicians having to decide on energy policies. Above all the study aimed at finding out about reactions, social protest, opposition or approval to be coped with by those who, having the say in political matters, want to speak up for one of the energy policies under public discussion. (orig./HSCH) [de

  13. Improving urban African Americans' blood pressure control through multi-level interventions in the Achieving Blood Pressure Control Together (ACT) study: a randomized clinical trial.

    Science.gov (United States)

    Ephraim, Patti L; Hill-Briggs, Felicia; Roter, Debra L; Bone, Lee R; Wolff, Jennifer L; Lewis-Boyer, LaPricia; Levine, David M; Aboumatar, Hanan J; Cooper, Lisa A; Fitzpatrick, Stephanie J; Gudzune, Kimberly A; Albert, Michael C; Monroe, Dwyan; Simmons, Michelle; Hickman, Debra; Purnell, Leon; Fisher, Annette; Matens, Richard; Noronha, Gary J; Fagan, Peter J; Ramamurthi, Hema C; Ameling, Jessica M; Charlston, Jeanne; Sam, Tanyka S; Carson, Kathryn A; Wang, Nae-Yuh; Crews, Deidra C; Greer, Raquel C; Sneed, Valerie; Flynn, Sarah J; DePasquale, Nicole; Boulware, L Ebony

    2014-07-01

    Given their high rates of uncontrolled blood pressure, urban African Americans comprise a particularly vulnerable subgroup of persons with hypertension. Substantial evidence has demonstrated the important role of family and community support in improving patients' management of a variety of chronic illnesses. However, studies of multi-level interventions designed specifically to improve urban African American patients' blood pressure self-management by simultaneously leveraging patient, family, and community strengths are lacking. We report the protocol of the Achieving Blood Pressure Control Together (ACT) study, a randomized controlled trial designed to study the effectiveness of interventions that engage patient, family, and community-level resources to facilitate urban African American hypertensive patients' improved hypertension self-management and subsequent hypertension control. African American patients with uncontrolled hypertension receiving health care in an urban primary care clinic will be randomly assigned to receive 1) an educational intervention led by a community health worker alone, 2) the community health worker intervention plus a patient and family communication activation intervention, or 3) the community health worker intervention plus a problem-solving intervention. All participants enrolled in the study will receive and be trained to use a digital home blood pressure machine. The primary outcome of the randomized controlled trial will be patients' blood pressure control at 12months. Results from the ACT study will provide needed evidence on the effectiveness of comprehensive multi-level interventions to improve urban African American patients' hypertension control. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Improved thrombogenicity on oxygen etched Ti6Al4V surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, Nicholas A. [Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523 (United States); Smith, Barbara S. [School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523 (United States); Williams, John D. [Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523 (United States); Popat, Ketul C., E-mail: ketul.popat@colostate.edu [Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523 (United States); School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523 (United States)

    2012-07-01

    Thrombus formation on blood contacting biomaterials continues to be a key factor in initiating a critical mode of failure in implantable devices, requiring immediate attention. In the interest of evaluating a solution for one of the most widely used biomaterials, titanium and its alloys, this study focuses on the use of a novel surface oxidation treatment to improve the blood compatibility. This study examines the possibility of using oblique angle ion etching to produce a high quality oxide layer that enhances blood compatibility on medical grade titanium alloy Ti6Al4V. An X-ray photoelectron spectroscopy (XPS) analysis of these oxygen-rich surfaces confirmed the presence of TiO{sub 2} peaks and also indicated increased surface oxidation as well as a reduction in surface defects. After 2 h of contact with whole human plasma, the oxygen etched substrates demonstrated a reduction in both platelet adhesion and activation as compared to bare titanium substrates. The whole blood clotting behavior was evaluated for up to 45 min, showing a significant decrease in clot formation on oxygen etched substrates. Finally, a bicinchoninic acid (BCA) total protein assay and XPS were used to evaluate the degree of key blood serum protein (fibrinogen, albumin, immunoglobulin G) adsorption on the substrates. The results showed similar protein levels for both the oxygen etched and control substrates. These results indicate that oblique angle oxygen etching may be a promising method to increase the thrombogenicity of Ti6Al4V. - Highlights: Black-Right-Pointing-Pointer Oblique angle oxygen ion etching creates a high quality, uniform oxide surface. Black-Right-Pointing-Pointer Oxygen etched substrates showed fewer adhered platelets. Black-Right-Pointing-Pointer Platelet activation was reduced by the improved oxide surface. Black-Right-Pointing-Pointer Oxygen etched substrates exhibited increased whole blood clotting times. Black-Right-Pointing-Pointer Although clotting reductions were

  15. Inducing PLA/starch compatibility through butyl-etherification of waxy and high amylose starch.

    Science.gov (United States)

    Wokadala, Obiro Cuthbert; Emmambux, Naushad Mohammad; Ray, Suprakas Sinha

    2014-11-04

    In this study, waxy and high amylose starches were modified through butyl-etherification to facilitate compatibility with polylactide (PLA). Fourier transform infrared spectroscopy, proton nuclear magnetic resonance spectroscopy and wettability tests showed that hydrophobic butyl-etherified waxy and high amylose starches were obtained with degree of substitution values of 2.0 and 2.1, respectively. Differential scanning calorimetry, tensile testing, and scanning electron microscopy (SEM) demonstrated improved PLA/starch compatibility for both waxy and high amylose starch after butyl-etherification. The PLA/butyl-etherified waxy and high amylose starch composite films had higher tensile strength and elongation at break compared to PLA/non-butyl-etherified composite films. The morphological study using SEM showed that PLA/butyl-etherified waxy starch composites had a more homogenous microstructure compared to PLA/butyl-etherified high amylose starch composites. Thermogravimetric analysis showed that PLA/starch composite thermal stability decreased with starch butyl-etherification for both waxy and high amylose starches. This study mainly demonstrates that PLA/starch compatibility can be improved through starch butyl-etherification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Blood genotyping for improved outcomes in chronic transfusion patients: current and future perspectives

    Directory of Open Access Journals (Sweden)

    Kutner JM

    2014-09-01

    Full Text Available Jose Mauro Kutner,1 Mariza Mota,1 Fabiana Conti,1 Lilian Castilho1,2 1Hemotherapy and Cell Therapy Department, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil; 2Hemocentro Unicamp, Campinas, SP, Brazil Abstract: Blood transfusions are life sustaining in chronically transfused patients. However, certain complications, such as alloimmunization to red blood cells, can create challenges in the management of those patients. Routine phenotyping of blood recipients and the use of phenotype-matched blood units for transfusion have been useful to lower the occurrence of red cell alloantibodies in chronically transfused individuals. Nevertheless, extensive phenotyping is expensive, laborious, and cannot be performed in certain situations. The molecular understanding of blood groups has enabled the design of assays that may be used to better guide matched red blood cell transfusions. This review summarizes key findings related to red cell alloimmunization, the already identified and potential future benefits of blood group genotyping, and how molecular typing is being incorporated in the blood bank's routine to improve clinical and long-term outcomes in chronically transfused patients. Keywords: blood group genotyping, chronically transfused patients, platelet genotyping, RBC alloimmunization

  17. Socially compatible technology management

    International Nuclear Information System (INIS)

    Tschiedel, R.

    1989-01-01

    The public has a critical eye on the impacts of technology, and there is a growing awareness of the social impacts in addition to health hazards and economic and ecologic impacts. 'Socially compatible technology management' is the magic formula frequently used which has emerged as a political demand in the course of the social controversy about the hazards of large-scale technology. It marks a position in the conflict between those who declare existing market and policy instruments to be sufficient regulatory tools, and those who understand the incidents ranging from inadequacy to desaster as a warning, and call for more precaution in decisions with an impact on the future. The concept of 'social compatibility' has to be given shape by elaborating criteria and methods for achieving this goal. The book shows that social compatibility cannot sufficiently be defined either as a quality of a technology and of a socio-technical system (acceptability), or as the willingness of the people concerned to accept a technology (acceptance). The investigation explains by means of empirical analysis and examples that participation is the only way to combine acceptability and acceptance into a socially compatibly designed technology. The leading theoretical and political formula developed for this purpose is 'acquisition'. To put it in a provocative way: Man has to learn to manage and master technical systems as if they were an integral part of themselves. Which means, man has to acquire the required knowledge and skill in the changing social structures, and the real power of disposal. Sociology of technology is a branch of research that can and should give support in the process of designing and managing technological systems in a way compatible with social needs. (orig./HP) [de

  18. Is it ethical to invite compatible pairs to participate in exchange programmes?

    Science.gov (United States)

    Fortin, Marie-Chantal

    2013-12-01

    Living kidney transplantation offers the best results for patients with end-stage renal disease (ESRD). This form of transplantation is no longer restricted to genetically or emotionally related donors, as shown by the acceptance of non-directed living anonymous donors, and the development of exchange programmes (EPs). EPs make it possible to perform living kidney transplantation among incompatible pairs, but while such programmes can help increase living organ donation, they can also create a degree of unfairness. Kidney transplant recipients in the O blood group are at a disadvantage when it comes to EPs because they can only receive organs from O donors, whereas O donors are universal donors. This poses a major challenge in terms of distributive justice and equity. A way to remedy this situation is through altruistic unbalanced paired kidney exchange (AUPKE), in which a compatible pair consisting of an O blood group donor and a non-O recipient is invited to participate in an EP. Although the AUPKE approach appears fairer for O recipients, it still raises ethical questions. How does this type of exchange affect the donor/recipient gift relationship? Should recipients in compatible pairs receive a 'better organ' than the one they would otherwise have received from their intended donor? Finally, what is the role of transplant teams in AUPKE? This article will examine the organisational and ethical challenges associated with EPs and AUPKE, and compare different EP policies in countries where such programmes exist.

  19. Inheritance of graft compatibility in Douglas fir.

    Science.gov (United States)

    D.L. Copes

    1973-01-01

    Graft compatibility of genetically related and unrelated rootstock-scion combinations was compared. Scion clones were 75% compatible when grafted on half-related rootstocks but only 56% compatible when grafted on unrelated rootstocks. Most variance associated with graft incompatibility in Douglas-fir appears to be caused by multiple genes.

  20. Patient-centric blood pressure-targeted cardiopulmonary resuscitation improves survival from cardiac arrest.

    Science.gov (United States)

    Sutton, Robert M; Friess, Stuart H; Naim, Maryam Y; Lampe, Joshua W; Bratinov, George; Weiland, Theodore R; Garuccio, Mia; Nadkarni, Vinay M; Becker, Lance B; Berg, Robert A

    2014-12-01

    Although current resuscitation guidelines are rescuer focused, the opportunity exists to develop patient-centered resuscitation strategies that optimize the hemodynamic response of the individual in the hopes to improve survival. To determine if titrating cardiopulmonary resuscitation (CPR) to blood pressure would improve 24-hour survival compared with traditional CPR in a porcine model of asphyxia-associated ventricular fibrillation (VF). After 7 minutes of asphyxia, followed by VF, 20 female 3-month-old swine randomly received either blood pressure-targeted care consisting of titration of compression depth to a systolic blood pressure of 100 mm Hg and vasopressors to a coronary perfusion pressure greater than 20 mm Hg (BP care); or optimal American Heart Association Guideline care consisting of depth of 51 mm with standard advanced cardiac life support epinephrine dosing (Guideline care). All animals received manual CPR for 10 minutes before first shock. Primary outcome was 24-hour survival. The 24-hour survival was higher in the BP care group (8 of 10) compared with Guideline care (0 of 10); P = 0.001. Coronary perfusion pressure was higher in the BP care group (point estimate +8.5 mm Hg; 95% confidence interval, 3.9-13.0 mm Hg; P < 0.01); however, depth was higher in Guideline care (point estimate +9.3 mm; 95% confidence interval, 6.0-12.5 mm; P < 0.01). Number of vasopressor doses before first shock was higher in the BP care group versus Guideline care (median, 3 [range, 0-3] vs. 2 [range, 2-2]; P = 0.003). Blood pressure-targeted CPR improves 24-hour survival compared with optimal American Heart Association care in a porcine model of asphyxia-associated VF cardiac arrest.

  1. An Automatic Lab-on-Disc System for Blood Typing.

    Science.gov (United States)

    Chang, Yaw-Jen; Fan, Yi-Hua; Chen, Shia-Chung; Lee, Kuan-Hua; Lou, Liao-Yong

    2018-04-01

    A blood-typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This article presents a lab-on-disc blood-typing system to conduct a total of eight assays for a patient, including forward-typing tests, reverse-typing tests, and irregular-antibody tests. These assays are carried out in a microfluidic disc simultaneously. A blood-typing apparatus was designed to automatically manipulate the disc. The blood type can be determined by integrating the results of red blood cell (RBC) agglutination in the microchannels. The experimental results of our current 40 blood samples show that the results agree with those examined in the hospital. The accuracy reaches 97.5%.

  2. Compatibility of Mating Preferences

    OpenAIRE

    Bingol, Haluk O.; Basar, Omer

    2016-01-01

    Human mating is a complex phenomenon. Although men and women have different preferences in mate selection, there should be compatibility in these preferences since human mating requires agreement of both parties. We investigate how compatible the mating preferences of men and women are in a given property such as age, height, education and income. We use dataset of a large online dating site (N = 44, 255 users). (i) Our findings are based on the "actual behavior" of users trying to find a dat...

  3. Patient-centric Blood Pressure–targeted Cardiopulmonary Resuscitation Improves Survival from Cardiac Arrest

    Science.gov (United States)

    Friess, Stuart H.; Naim, Maryam Y.; Lampe, Joshua W.; Bratinov, George; Weiland, Theodore R.; Garuccio, Mia; Nadkarni, Vinay M.; Becker, Lance B.; Berg, Robert A.

    2014-01-01

    Rationale: Although current resuscitation guidelines are rescuer focused, the opportunity exists to develop patient-centered resuscitation strategies that optimize the hemodynamic response of the individual in the hopes to improve survival. Objectives: To determine if titrating cardiopulmonary resuscitation (CPR) to blood pressure would improve 24-hour survival compared with traditional CPR in a porcine model of asphyxia-associated ventricular fibrillation (VF). Methods: After 7 minutes of asphyxia, followed by VF, 20 female 3-month-old swine randomly received either blood pressure–targeted care consisting of titration of compression depth to a systolic blood pressure of 100 mm Hg and vasopressors to a coronary perfusion pressure greater than 20 mm Hg (BP care); or optimal American Heart Association Guideline care consisting of depth of 51 mm with standard advanced cardiac life support epinephrine dosing (Guideline care). All animals received manual CPR for 10 minutes before first shock. Primary outcome was 24-hour survival. Measurements and Main Results: The 24-hour survival was higher in the BP care group (8 of 10) compared with Guideline care (0 of 10); P = 0.001. Coronary perfusion pressure was higher in the BP care group (point estimate +8.5 mm Hg; 95% confidence interval, 3.9–13.0 mm Hg; P < 0.01); however, depth was higher in Guideline care (point estimate +9.3 mm; 95% confidence interval, 6.0–12.5 mm; P < 0.01). Number of vasopressor doses before first shock was higher in the BP care group versus Guideline care (median, 3 [range, 0–3] vs. 2 [range, 2–2]; P = 0.003). Conclusions: Blood pressure–targeted CPR improves 24-hour survival compared with optimal American Heart Association care in a porcine model of asphyxia-associated VF cardiac arrest. PMID:25321490

  4. Effect of halloysite nanotubes on the structure and function of important multiple blood components

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Keke; Feng, Ru; Jiao, Yanpeng, E-mail: tjiaoyp@jnu.edu.cn; Zhou, Changren

    2017-06-01

    Many researchers have investigated the application of halloysite nanotubes (HNTs) in biomedicine, because of their special nanoscale hollow tubular structure. Although the cytocompatibility of HNTs has been studied, their blood compatibility has not been systematically investigated. In this work, the effect of HNTs on the structure and function of different blood components has been studied, including the morphology and hemolysis of red blood cells (RBCs). Based on scanning electron microscopy (SEM) observations, optical density test and flow cytometry analysis, we found that HNTs can affect the morphology and membrane integrity of RBCs in phosphate buffered saline (PBS) in a content-dependent way. In particular, based on UV–vis absorption spectra, fluorescence spectra and circular dichroism (CD) spectra, HNTs can alter the secondary structure and conformation of human fibrinogen and γ-globulins. In addition, the detection of biomarker molecules C3a and C5a in plasma suggests that HNTs can trigger complement activation. In the blood clotting assay, HNTs were found to significantly prolong the activated partial thromboplastin time (APTT), shorten the prothrombin time (PT) of platelet-poor plasma (PPP), and change the thromboelastography (TEG) parameters of whole blood coagulation. Furthermore, confocal laser scanning microscopy and flow cytometry analysis were used to test intracellular uptake by macrophages, and the cellular uptake of HNTs in the RAW 264.7 was found to be content-dependent, but not time-dependent. These findings provide insight for the potential use of HNTs as biofriendly nanocontainers for biomaterials in vivo. - Highlights: • Comprehensive study of blood compatibility halloysite nanotubes (HNTs) is processed. • We examine and analyze the effect of HNTs on conformation changes of three plasma proteins. • We prove HNTs can affect blood components at high content but little at low content. • We prove HNTs could be used as biomaterials

  5. Effect of halloysite nanotubes on the structure and function of important multiple blood components

    International Nuclear Information System (INIS)

    Wu, Keke; Feng, Ru; Jiao, Yanpeng; Zhou, Changren

    2017-01-01

    Many researchers have investigated the application of halloysite nanotubes (HNTs) in biomedicine, because of their special nanoscale hollow tubular structure. Although the cytocompatibility of HNTs has been studied, their blood compatibility has not been systematically investigated. In this work, the effect of HNTs on the structure and function of different blood components has been studied, including the morphology and hemolysis of red blood cells (RBCs). Based on scanning electron microscopy (SEM) observations, optical density test and flow cytometry analysis, we found that HNTs can affect the morphology and membrane integrity of RBCs in phosphate buffered saline (PBS) in a content-dependent way. In particular, based on UV–vis absorption spectra, fluorescence spectra and circular dichroism (CD) spectra, HNTs can alter the secondary structure and conformation of human fibrinogen and γ-globulins. In addition, the detection of biomarker molecules C3a and C5a in plasma suggests that HNTs can trigger complement activation. In the blood clotting assay, HNTs were found to significantly prolong the activated partial thromboplastin time (APTT), shorten the prothrombin time (PT) of platelet-poor plasma (PPP), and change the thromboelastography (TEG) parameters of whole blood coagulation. Furthermore, confocal laser scanning microscopy and flow cytometry analysis were used to test intracellular uptake by macrophages, and the cellular uptake of HNTs in the RAW 264.7 was found to be content-dependent, but not time-dependent. These findings provide insight for the potential use of HNTs as biofriendly nanocontainers for biomaterials in vivo. - Highlights: • Comprehensive study of blood compatibility halloysite nanotubes (HNTs) is processed. • We examine and analyze the effect of HNTs on conformation changes of three plasma proteins. • We prove HNTs can affect blood components at high content but little at low content. • We prove HNTs could be used as biomaterials

  6. Blood and Blood Product Conservation: Results of Strategies to Improve Clinical Outcomes in Open Heart Surgery Patients at a Tertiary Hospital.

    Science.gov (United States)

    Khan, Junaid H; Green, Emily A; Chang, Jimmin; Ayala, Alexandria M; Barkin, Marilyn S; Reinys, Emily E; Stanton, Jeffrey; Stanten, Russell D

    2017-12-01

    Blood product usage is a quality outcome for patients undergoing cardiac surgery. To address an increase in blood product usage since the discontinuation of aprotinin, blood conservation strategies were initiated at a tertiary hospital in Oakland, CA. Improving transfusion rates for open heart surgery patients requiring Cardiopulmonary bypass (CPB) involved multiple departments in coordination. Specific changes to conserve blood product usage included advanced CPB technology upgrades, and precise individualized heparin dose response titration assay for heparin and protamine management. Retrospective analysis of blood product usage pre-implementation, post-CPB changes and post-Hemostasis Management System (HMS) implementation was done to determine the effectiveness of the blood conservation strategies. Statistically significant decrease in packed red blood cells, fresh frozen plasma, cryoprecipitate, and platelet usage over the stepped implementation of both technologies was observed. New oxygenator and centrifugal pump technologies reduced active circuitry volume and caused less damage to blood cells. Individualizing heparin and protamine dosing to a patient using the HMS led to transfusion reductions as well. Overall trends toward reductions in hospital length of stay and intensive care unit stay, and as a result, blood product cost and total hospitalization cost are positive over the period of implementation of both CPB circuit changes and HMS implementation. Although they are multifactorial in nature, these trends provide positive enforcement to the changes implemented.

  7. Mechanisms of immune red cell destruction, and red cell compatibility testing

    International Nuclear Information System (INIS)

    Garratty, G.

    1983-01-01

    The immune destruction of red cells can occur as a complement-mediated intravascular process, or extravascularly, where the red cells are destroyed by macrophages following interaction with cell-bound IgG1, IgG3, and/or C3b. Many of the factors that affect this in vivo destruction are not taken into account during in vitro pretransfusion compatibility testing. At present, even by use of more elaborate tests, it is difficult to accurately predict the fate of a transfused unit of blood. By using some simple information, such as antibody specificity and thermal range, it is sometimes possible to predict the outcome of transfusing a unit of blood that is incompatible in vitro. At other times it may be necessary to utilize 51 Cr-labeled red cells to determine the risk of transfusing such units. Because of the paucity of reported clinical correlations, macrophage/monocyte monolayer assays are of little practical value at present

  8. Bedtime Blood Pressure Chronotherapy Significantly Improves Hypertension Management.

    Science.gov (United States)

    Hermida, Ramón C; Ayala, Diana E; Fernández, José R; Mojón, Artemio; Crespo, Juan J; Ríos, María T; Smolensky, Michael H

    2017-10-01

    Consistent evidence of numerous studies substantiates the asleep blood pressure (BP) mean derived from ambulatory BP monitoring (ABPM) is both an independent and a stronger predictor of cardiovascular disease (CVD) risk than are daytime clinic BP measurements or the ABPM-determined awake or 24-hour BP means. Hence, cost-effective adequate control of sleep-time BP is of marked clinical relevance. Ingestion time, according to circadian rhythms, of hypertension medications of 6 different classes and their combinations significantly improves BP control, particularly sleep-time BP, and reduces adverse effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Blood flow dynamic improvement with aneurysm repair detected by a patient-specific model of multiple aortic aneurysms.

    Science.gov (United States)

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Yamazaki, Kenji; Tsubota, Ken'ichi; Liang, Fuyou; Liu, Hao

    2014-05-01

    Aortic aneurysms may cause the turbulence of blood flow and result in the energy loss of the blood flow, while grafting of the dilated aorta may ameliorate these hemodynamic disturbances, contributing to the alleviation of the energy efficiency of blood flow delivery. However, evaluating of the energy efficiency of blood flow in an aortic aneurysm has been technically difficult to estimate and not comprehensively understood yet. We devised a multiscale computational biomechanical model, introducing novel flow indices, to investigate a single male patient with multiple aortic aneurysms. Preoperative levels of wall shear stress and oscillatory shear index (OSI) were elevated but declined after staged grafting procedures: OSI decreased from 0.280 to 0.257 (first operation) and 0.221 (second operation). Graftings may strategically counter the loss of efficient blood delivery to improve hemodynamics of the aorta. The energy efficiency of blood flow also improved postoperatively. Novel indices of pulsatile pressure index (PPI) and pulsatile energy loss index (PELI) were evaluated to characterize and quantify energy loss of pulsatile blood flow. Mean PPI decreased from 0.445 to 0.423 (first operation) and 0.359 (second operation), respectively; while the preoperative PELI of 0.986 dropped to 0.820 and 0.831. Graftings contributed not only to ameliorate wall shear stress or oscillatory shear index but also to improve efficient blood flow. This patient-specific modeling will help in analyzing the mechanism of aortic aneurysm formation and may play an important role in quantifying the energy efficiency or loss in blood delivery.

  10. Scaling Rule for Very Shallow Trench IGBT toward CMOS Process Compatibility

    OpenAIRE

    Tanaka, Masahiro; Omura, Ichiro

    2012-01-01

    Deep trench gate is used for latest IGBT to improve device performance. By large difference from deep submicron CMOS structure, there is no process compatibility among CMOS device and trench gate IGBT. We propose IGBT scaling rule for shrinking IGBT cell structure both horizontally and vertically. The scaling rule is theoretically delivered by structure based equations. Device performance improvement was also predicted by TCAD simulations even with very shallow trench gate. The rule enables t...

  11. [Applications of mathematical statistics methods on compatibility researches of traditional Chinese medicines formulae].

    Science.gov (United States)

    Mai, Lan-Yin; Li, Yi-Xuan; Chen, Yong; Xie, Zhen; Li, Jie; Zhong, Ming-Yu

    2014-05-01

    The compatibility of traditional Chinese medicines (TCMs) formulae containing enormous information, is a complex component system. Applications of mathematical statistics methods on the compatibility researches of traditional Chinese medicines formulae have great significance for promoting the modernization of traditional Chinese medicines and improving clinical efficacies and optimizations of formulae. As a tool for quantitative analysis, data inference and exploring inherent rules of substances, the mathematical statistics method can be used to reveal the working mechanisms of the compatibility of traditional Chinese medicines formulae in qualitatively and quantitatively. By reviewing studies based on the applications of mathematical statistics methods, this paper were summarized from perspective of dosages optimization, efficacies and changes of chemical components as well as the rules of incompatibility and contraindication of formulae, will provide the references for further studying and revealing the working mechanisms and the connotations of traditional Chinese medicines.

  12. Maduramicin and tiamulin compatibility in broiler chickens.

    Science.gov (United States)

    Badiola, J J; Luco, D F; Perez, V; Vargas, M A; Lujan, L; Marin, J F

    1994-03-01

    A total of 480 1-day-old Hybro broiler chickens were divided into five treatment groups (A: unmedicated control, B: maduramicin, C: maduramicin + tiamulin, D: monensin + tiamulin and E: tiamulin) to study the effect on performance parameters, organ weights, blood haematology and biochemistry, and histopathology of liver and selected striated muscles, when maduramicin at 5 parts/10(6) and monensin at 100 parts/10(6) were included in feed in starter and grower periods, and tiamulin 9 in water at 270 parts/10(6) the recommended therapeutic level, from day 28 to 31. Performance parameters were significantly and negatively affected by monensin but not by maduramicin after treatment with tiamulin. Histopathological examination of striated muscles showed no incompatibility of maduramicin + tiamulin, while lesions were found in the monensin + tiamulin treated group. It is concluded that the use of tiamulin to a therapeutic level for 3 consecutive days is compatible with the simultaneous presence of maduramicin in the feed of broilers.

  13. Influences of layer thickness on the compatibility and physical properties of polycarbonate/polystyrene multilayered film via nanolayer coextrusion

    Science.gov (United States)

    Cheng, Junfeng; Chen, Zhiru; Zhou, Jiaqi; Cao, Zheng; Wu, Dun; Liu, Chunlin; Pu, Hongting

    2018-05-01

    The effects of layer thickness on the compatibility between polycarbonate (PC) and polystyrene (PS) and physical properties of PC/PS multilayered film via nanolayer coextrusion are studied. The morphology of multilayered structure is observed using a scanning electron microscope. This multilayered structure may have a negative impact on the transparency, but it can improve the water resistance and heat resistance of film. To characterize the compatibility between PC and PS, differential scanning calorimetry is used to measure the glass transition temperature. The compatibility is found to be improved with the decrease of layer thickness. Therefore, the viscosity of multilayered film is also reduced with the decrease of layer thickness. In addition, the multilayered structure can improve the tensile strength with the increase of layer numbers. Because of the complete and continuous layer structure of PC, the PC/PS multilayered film can retain its mechanical strength at the temperature above Tg of PS.

  14. Common fixed point theorems for weakly compatible mappings in fuzzy metric spaces

    Directory of Open Access Journals (Sweden)

    Sunny Chauhan

    2013-05-01

    Full Text Available The aim of this paper is to prove a common fixed point theorem for a pair of weakly compatible mappings in fuzzy metric space by using the (CLRg property. An example is also furnished which demonstrates the validity of our main result. As an application to our main result, we present a fixed point theorem for two finite families of self mappings in fuzzy metric space by using the notion of pairwise commuting. Our results improve the results of Sedghi, Shobe and Aliouche [A common fixed point theorem for weakly compatible mappings in fuzzy metric spaces, Gen. Math. 18(3 (2010, 3-12 MR2735558].

  15. Analysis of inorganic elements in blood of albino rabbit using NAA

    International Nuclear Information System (INIS)

    Metairon, Sabrina; Zamboni, Cibele B.; Medeiros, Ilca M.M.A.

    2009-01-01

    In this work Br, Cl, K and Na concentrations in albino rabbit blood were determinate using NAA. They are the first indicative interval for reference values in whole blood and they could be used for checking the clinical status of this specie when it will be used was animal model. The results when compared with human whole blood estimation suggest compatibility for Br, Cl and K considering 95% of confidence interval but, for Na the levels are altered, suggesting physiologic differences. (author)

  16. How do I provide leukapheresis products? Blood center experience and evidence for process improvement.

    Science.gov (United States)

    Ginzburg, Yelena; Kessler, Debra; Narici, Manlio; Caltabiano, Melinda; Rebosa, Mark; Strauss, Donna; Shaz, Beth

    2013-10-01

    The past few decades have seen a resurgence of interest in leukapheresis products to improve the survival of infected patients with neutropenia. These products have a short shelf life and require donor stimulation with dexamethasone before collection. Additionally, a system with good communications and logistical support is essential. A recent survey of blood centers in North America revealed that the majority of centers collecting leukapheresis products use steroid-stimulated donors. The survey results suggested that an analysis of the process and potential process improvement would be of interest to the transfusion medicine community. Data from 2008 to 2011 regarding donor selection, donor dexamethasone stimulation, leukapheresis collection, and correlations between potentially pertinent variables for process improvement were analyzed. Results from an analysis of cost are also included. We evaluate 432 leukapheresis donations and demonstrate correlations between 1) pre- and poststimulation white blood cell (WBC) count (pproduct granulocyte yield (pimprovement in granulocyte quality and yield can be accomplished in dexamethasone-stimulated donors, by selecting eligible donors with relatively high normal prestimulation WBC counts and/or previously good responses to dexamethasone, increasing the duration between dexamethasone stimulation and granulocyte collection, and maintaining optimal hematocrit (5%-10%) in granulocyte collections. Because the majority of surveyed blood centers collecting stimulated granulocytes use steroids alone, modifications presented here may prove useful. Further assessment of correlation between granulocyte yield and clinical outcome will await results of additional studies. © 2012 American Association of Blood Banks.

  17. The Effect of Birth Order on Roommate Compatibility

    Science.gov (United States)

    Schuh, John H.; Williams, Ondre J.

    1977-01-01

    A group of students were matched on the basis of compatible birth order; another was matched on the basis of conflicting birth order. After a month's experience in a residence hall their compatibility was examined. Students with conflicting birth order were more compatible than those with the same birth order. (Author)

  18. Novel silicone compatible cross-linkers for controlled functionalization of PDMS networks

    DEFF Research Database (Denmark)

    Madsen, Frederikke Bahrt; Daugaard, Anders Egede; Hvilsted, Søren

    2013-01-01

    . In order to improve the dielectric properties of PDMS a novel system is developed where push-pull dipoles are grafted to a new silicone compatible cross-linker. The grafted cross-linkers are prepared by reaction of two different push-pull dipole alkynes as well as a fluorescent alkyne with the new azide...

  19. An Experimental Study to Replace the Thoracic Descending Aorta for Pigs with a Self-Made Sutureless Blood Vessel

    Directory of Open Access Journals (Sweden)

    Fenglin Song

    2014-01-01

    Full Text Available To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we carried thoracic descending aorta replacement using either SMSBV or Gore-Tex, respectively, in pigs. The aortic clamp time and the operative blood loss in the experimental group (using SMSBV were less than those in the control group (using Gore-Tex. The whole blood hematocrit, platelet count, plasma soluble P-selectin, plasma free hemoglobin, and interleukins 2, 6 at each time point were not different significantly between the two groups. Light microscopy and transmission electron microscopy examination showed there were layers of vascular smooth muscle cells and endothelial cells adhered in the inner wall of artificial blood vessel without any signs of thrombosis. Based on the result, we have drawn the conclusion that the application of SMSBV can significantly shorten the vascular anastomosis time, reduce operative blood loss, and show good blood and tissue compatibility.

  20. [Magnetic resonance compatibility research for coronary mental stents].

    Science.gov (United States)

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  1. Nitric oxide releasing silicone rubbers with improved blood compatibility: preparation, characterization, and in vivo evaluation.

    Science.gov (United States)

    Zhang, Huiping; Annich, Gail M; Miskulin, Judiann; Osterholzer, Kathryn; Merz, Scott I; Bartlett, Robert H; Meyerhoff, Mark E

    2002-03-01

    Nitric oxide (NO) releasing silicone rubbers (SR) are prepared via a three-step reaction scheme. A diamino triaminoalkyltrimethoxysilane crosslinker is used to vulcanize hydroxyl terminated polydimethylsiloxane (PDMS) in the presence of ambient moisture and a dibutyltin dilaurate catalyst so that the respective diamine triamine groups are covalently linked to the cured SR structure. These amine sites are then diazeniumdiolated, in situ, when the cured SR is reacted with NO at elevated pressure (80 psi). Although nitrite species are also formed during the NO addition reaction, in most cases the diazeniumdiolated polymer is the major product within the final SR matrix. Temperature appears to be the major driving force for the dissociation of the attached diazeniumdiolate moieties, whereas the presence of bulk water bathing the SR materials has only minimal effect on the observed NO release rate owing to the low water uptake of the SR matrices. The resulting SR films/coatings release NO at ambient or physiological temperature for up to 20 d with average fluxes of at least 4 x 10(10) mol x cm(-2) x min(-1) (coating thickness > or = 600 microm) over first 4 h, comparable to the NO fluxes observed from stimulated human endothelial cells. The NO loading and concomitant NO release flux of the SR material are readily adjustable by altering the diamine triamine loading and film/coating thickness. The new NO releasing SR materials are shown to exhibit improved thromboresistance in vivo, as demonstrated via reduced platelet activation on the surface of these polymers when used to coat the inner walls of SR tubings employed for extracorporeal circulation in a rabbit model.

  2. Quadratic Poisson brackets compatible with an algebra structure

    OpenAIRE

    Balinsky, A. A.; Burman, Yu.

    1994-01-01

    Quadratic Poisson brackets on a vector space equipped with a bilinear multiplication are studied. A notion of a bracket compatible with the multiplication is introduced and an effective criterion of such compatibility is given. Among compatible brackets, a subclass of coboundary brackets is described, and such brackets are enumerated in a number of examples.

  3. Improving the Blood Pressure Control With the ProActive Attitude of Hypertensive Patients Seeking Follow-up Services

    Science.gov (United States)

    Tang, Shangfeng; Bishwajit, Ghose; Ji, Lu; Feng, Da; Fang, Haiqing; Fu, Hang; Shao, Tian; Shao, Piaopiao; Liu, Chunyan; Feng, Zhanchun; Luba, Tegene R.

    2016-01-01

    Abstract Proactive attitude of hypertensive patients seeking follow-up services (FUS) lies at the core of self-efficacy. However, few evidence have shown the activeness of seeking FUS in the context of blood pressure control among hypertensive patients. Improvements in follow-up visits may not just by services itself cause better control of blood pressure among hypertensive patients, rather due to the patient's pro-active attitude of the patient in seeking FUS. A cross-sectional study was carried out in selected rural regions of China to explore the association between blood pressure control and sociodemographic and economic variables and activeness of hypertensive patients in seeking FUS. The primary clinical outcome for this study was blood pressure control (systolic blood pressure seekers were 3.17 times greater than those of passive seekers (odds ratio [OR] = 3.17, 95% confidence interval [CI] = 2.56–3.93, P passively. Proactive attitude of seeking follow-up services can improve blood pressure control among hypertensive patients. PMID:27057859

  4. Clinical effects of blood donor characteristics in transfusion recipients: protocol of a framework to study the blood donor-recipient continuum.

    Science.gov (United States)

    Chassé, Michaël; McIntyre, Lauralyn; Tinmouth, Alan; Acker, Jason; English, Shane W; Knoll, Greg; Forster, Alan; Shehata, Nadine; Wilson, Kumanan; van Walraven, Carl; Ducharme, Robin; Fergusson, Dean A

    2015-01-19

    When used appropriately, transfusion of red blood cells (RBCs) is a necessary life-saving therapy. However, RBC transfusions have been associated with negative outcomes such as infection and organ damage. Seeking explanations for the beneficial and deleterious effects of RBC transfusions is necessary to ensure the safe and optimal use of this precious resource. This study will create a framework to analyse the influence of blood donor characteristics on recipient outcomes. We will conduct a multisite, longitudinal cohort study using blood donor data routinely collected by Canadian Blood Services, and recipient data from health administrative databases. Our project will include a thorough validation of primary data, the linkage of various databases into one large longitudinal database, an in-depth epidemiological analysis and a careful interpretation and dissemination of the results to assist the decision-making process of clinicians, researchers and policymakers in transfusion medicine. Our primary donor characteristic will be age of blood donors and our secondary donor characteristics will be donor-recipient blood group compatibility and blood donor sex. Our primary recipient outcome will be a statistically appropriate survival analysis post-RBC transfusion up to a maximum of 8 years. Our secondary recipient outcomes will include 1-year, 2-year and 5-year mortality; hospital and intensive care unit length of stay; rehospitalisation; new cancer and cancer recurrence rate; infection rate; new occurrence of myocardial infarctions and need for haemodialysis. Our results will help determine whether we need to tailor transfusion based on donor characteristics, and perhaps this will improve patient outcome. Our results will be customised to target the different stakeholders involved with blood transfusions and will include presentations, peer-reviewed publications and the use of the dissemination network of blood supply organisations. We obtained approval from the

  5. Tank Farm Waste Transfer Compatibility Program

    International Nuclear Information System (INIS)

    FOWLER, K.D.

    2001-01-01

    The compatibility program described in this document formalizes the process for determining waste compatibility. The primary goal of the program is to ensure that sufficient controls are in place to prevent the formation of incompatible mixtures during future operations. The process described involves characterizing waste, comparing characteristics with criteria, resolving potential incompatibilities and documenting the process

  6. 9 CFR 3.7 - Compatible grouping.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Compatible grouping. 3.7 Section 3.7... Cats 1 Animal Health and Husbandry Standards § 3.7 Compatible grouping. Dogs and cats that are housed...; (c) Puppies or kittens 4 months of age or less may not be housed in the same primary enclosure with...

  7. Tank Farm Waste Transfer Compatibility Program

    International Nuclear Information System (INIS)

    FOWLER, K.D.

    2000-01-01

    The compatibility program described in this document formalizes the process for determining waste compatibility. The primary goal of the program is to ensure that sufficient controls are in place to prevent the formation of incompatible mixtures during future operations. The process described involves characterizing waste, comparing characteristics with criteria, resolving potential incompatibilities and documenting the process

  8. Improved coagulation and blood conservation in the golden hours after cardiopulmonary bypass.

    Science.gov (United States)

    Beckmann, Scott R; Carlile, Dee; Bissinger, Randall C; Burrell, M; Winkler, Thomas; Shely, William W

    2007-06-01

    The Hemobag (HB) technique allows the open-heart team to safely concentrate the residual cardiopulmonary bypass (CPB) circuit contents and return a high volume of concentrated clotting factors and blood cells back to the patient as autotransfusion. Hematocrit, platelet count, fibrinogen concentration ([Fib]), prothrombin time (PT), partial thromboplastin time (PTT), and international normalized ratio (INR) were compared between two prospective convenience groups of cardiac surgical patients whose residual circuit blood was processed by the HB (n=10) or by the Cell Saver (CS; n=10) at two times after CPB: (a) after acute normovolemic hemodilution (ANH) infusion and protamine administration and (b) after admission to the intensive care unit (ICU), approximately 1 hour after CPB and HB content infusion. Minimal cell processing was also used in the HB patients to conserve blood. "Golden hours" is defined as the first few hours after CPB and protamine sulfate administration and extend into the ICU, when maintaining hemostasis is vital during cardiac surgery and is the most susceptible period for blood product administration and the opportunity to improve patient outcome. Except for PTT, all parameters changed significantly from the ANH infusion and protamine administration to approximately 1 hour after HB blood infusion and arrival in the ICU. Fibrinogen (p = .048) and hematocrit (p = .046) were significantly higher in the HB group compared with the CS group at the end of the golden hour despite infusion of significantly more allogeneic blood products (p = .070) and more washed red blood cells (RBCs; p = .001) in the CS group. All but one of the HB patients did not receive any allogeneic blood products during the golden hours. Use of the HB technique for salvaging blood is associated with significant increases in the patient's protein and cellular concentrations and lowered coagulation times in the important, first few golden hours after CPB, and except for one patient

  9. Distribution of ABO and Rh-D blood groups in the Benin area of Niger-Delta: Implication for regional blood transfusion

    Directory of Open Access Journals (Sweden)

    Enosolease Mathew

    2008-01-01

    Full Text Available ABO and Rhesus (Rh blood group antigens are hereditary characters and are useful in population genetic studies, in resolving medico-legal issues and more importantly in compatibility test in blood transfusion practice. Data on frequency distribution of ABO and Rh-D in Niger-Delta region of Nigeria are not available; hence we made an attempt to retrospectively analyze the records on the blood donors, transfusion recipients and patients attending antenatal care or some other medical interventions. Over a twenty-year period between 1986 and 2005, a total of 160,431 blood samples were grouped for ABO and Rh-D at the blood bank of the University of Benin Teaching Hospital, Benin City, Nigeria. Blood group distribution among these samples showed phenotypes A, B, AB and O as 23.72%, 20.09%, 2.97% and 53.22%, respectively. The Rh-D negative phenotype was found among 6.01% of the samples tested.

  10. AS-7 improved in vitro quality of red blood cells prepared from whole blood held overnight at room temperature.

    Science.gov (United States)

    Veale, Margaret F; Healey, Geraldine; Sran, Amrita; Payne, Katherine A; Zia, Majid; Sparrow, Rosemary L

    2015-01-01

    Extended room temperature (RT) hold of whole blood (WB) may affect the quality of red blood cell (RBC) components produced from these donations. The availability of better RBC additive solutions (ASs) may help reduce the effects. A new AS, AS-7 (SOLX, Haemonetics Corporation), was investigated for improved in vitro quality of RBCs prepared from WB held overnight at RT. Sixteen WB units were held for 21.4 hours ± 40 minutes at 22°C on cooling plates before processing. Each pair of ABO-matched WB units were pooled, divided into a WB filter pack containing saline-adenine-glucose-mannitol (control) and a LEUKOSEP WB-filter pack containing SOLX, and processed according to manufacturer's instructions. RBCs were stored at 2 to 6°C and sampled weekly until expiry. Glycophorin A (GPA+) and annexin V-binding microparticles (MPs) were quantitated using flow cytometry. Osmotic fragility, intracellular pH (pHi), adenosine triphosphate (ATP), 2,3-diphosphoglycerate (2,3-DPG), and routine quality variables were measured. Adhesion of RBCs to human endothelial cells (ECs) was evaluated by flow perfusion under low shear stress (0.5 dyne/cm(2) ), similar to low blood flow in microvessels. ATP and 2,3-DPG levels were improved for SOLX-RBCs. SOLX-RBCs maintained higher pHi, increased resistance to hypotonic stress, and reduced numbers of GPA+ MPs. No significant difference was observed between annexin V binding to MPs or adhesion of RBCs to ECs under shear stress. SOLX-stored RBCs showed increased osmotic resistance, pHi, and reduced GPA+ MPs and together with higher ATP and 2,3-DPG levels demonstrated improved in vitro RBC quality measures during 42 days of storage. © 2014 AABB.

  11. Preliminary assessment on compatibility of DUPIC fuel with CANDU-6

    International Nuclear Information System (INIS)

    Choi, Hang-Bok; Roh, G.H.; Jeong, C.J.; Rhee, B.W.; Choi, J.W.; Boss, C.R.

    1997-01-01

    The compatibility of DUPIC fuel with the existing CANDU-6 reactor was assessed. The technical issues of DUPIC fuel compatibility were chosen based on the CANDU physics design requirements and inherent characteristics of DUPIC fuel. The compatibility was assessed for the reference DUPIC fuel composition which was determined to reduce the composition heterogeneity and improve the spent PWR fuel utilization. Preliminary studies on a CANDU core loaded with DUPIC fuel have shown that the nominal power distribution is flatter than that of a natural uranium core when a 2-bundle shift refueling scheme is used, which reduces the reactivity worths of devices in the core and, therefore, the performance of reactivity devices was assessed. The safety of the core was assessed by a LOCA simulation and it was found that the power pulse upon LOCA can be maintained below that in the natural uranium core when a poison material is used in the DUPIC fuel. For the feasibility of handling DUPIC fuel in the plant, it will be necessary to introduce new equipment to load the DUPIC fuel in the refueling magazine. The radiation effect of DUPIC fuel on both the reactor hardware and the environment will be qualitatively analyzed later. (author)

  12. Compatibility analysis of 3D printer resin for biological applications

    KAUST Repository

    Sivashankar, Shilpa

    2016-08-30

    The salient features of microfluidics such as reduced cost, handling small sample and reagent volumes and less time required to fabricate the devices has inspired the present work. The incompatibility of three-dimensional printer resins in their native form and the method to improve their compatibility to many biological processes via surface modification are reported. The compatibility of the material to build microfluidic devices was evaluated in three different ways: (i) determining if the ultraviolet (UV) cured resin inhibits the polymerase chain reaction (PCR), i.e. testing devices for PCR compatibility; (ii) observing agglutination complex formed on the surface of the UV cured resin when anti-C-reactive protein (CRP) antibodies and CRP proteins were allowed to agglutinate; and (iii) by culturing human embryonic kidney cell line cells and testing for its attachment and viability. It is shown that only a few among four in its native form could be used for fabrication of microchannels and that had the least effect on biological molecules that could be used for PCR and protein interactions and cells, whereas the others were used after treating the surface. Importance in building lab-on-chip/micrototal analysis systems and organ-on-chip devices is found.

  13. Promoting sustainability in quality improvement: an evaluation of a web-based continuing education program in blood pressure measurement.

    Science.gov (United States)

    Block, Lauren; Flynn, Sarah J; Cooper, Lisa A; Lentz, Caroline; Hull, Tammie; Dietz, Katherine B; Boonyasai, Romsai T

    2018-01-10

    The accuracy of blood pressure measurement is variable in office-based settings. Even when staff training programs are effective, knowledge and skills decay over time, supporting the need for ongoing staff training. We evaluated whether a web-based continuing education program in blood pressure measurement reinforced knowledge and skills among clinical staff and promoted sustainability of an existing quality improvement program. Medical assistants and nurses at six primary care clinics within a health system enrolled in a 30-min online educational program designed to refresh their knowledge of blood pressure measurement. A 20-question pre- and post-intervention survey addressed learners' knowledge and attitudes. Direct observation of blood pressure measurement technique before and after the intervention was performed. Differences in responses to pre- and post-module knowledge and attitudes questions and in observation data were analyzed using chi-square tests and simple logistic regression. All 88 clinical staff members participated in the program and completed the evaluation survey. Participants answered 80.6% of questions correctly before the module and 93.4% afterwards (p blood pressure measurement were high at baseline and did not improve significantly. Prior to the intervention, staff adhered to 9 of 18 elements of the recommended technique during at least 90% of observations. Following the program, staff was more likely to explain the protocol, provide a rest period, measure an average blood pressure, and record the average blood pressure, but less likely to measure blood pressure with the arm at heart level and use the right arm. We designed, implemented, and evaluated a web-based educational program to improve knowledge, skills, and attitudes in blood pressure measurement and use of an automated device among nurses and medical assistants in ambulatory care. The program reinforced knowledge related to recommended blood pressure measurement technique

  14. Improving Corrosion Resistance and Biocompatibility of Magnesium Alloy by Sodium Hydroxide and Hydrofluoric Acid Treatments

    Directory of Open Access Journals (Sweden)

    Chang-Jiang Pan

    2016-12-01

    Full Text Available Owing to excellent mechanical property and biodegradation, magnesium-based alloys have been widely investigated for temporary implants such as cardiovascular stent and bone graft; however, the fast biodegradation in physiological environment and the limited surface biocompatibility hinder their clinical applications. In the present study, magnesium alloy was treated by sodium hydroxide (NaOH and hydrogen fluoride (HF solutions, respectively, to produce the chemical conversion layers with the aim of improving the corrosion resistance and biocompatibility. The results of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR and X-ray photoelectron spectroscopy (XPS indicated that the chemical conversion layers of magnesium hydroxide or magnesium fluoride were obtained successfully. Sodium hydroxide treatment can significantly enhance the surface hydrophilicity while hydrogen fluoride treatment improved the surface hydrophobicity. Both the chemical conversion layers can obviously improve the corrosion resistance of the pristine magnesium alloy. Due to the hydrophobicity of magnesium fluoride, HF-treated magnesium alloy showed the relative better corrosion resistance than that of NaOH-treated substrate. According to the results of hemolysis assay and platelet adhesion, the chemical surface modified samples exhibited improved blood compatibility as compared to the pristine magnesium alloy. Furthermore, the chemical surface modified samples improved cytocompatibility to endothelial cells, the cells had better cell adhesion and proliferative profiles on the modified surfaces. Due to the excellent hydrophilicity, the NaOH-treated substrate displayed better blood compatibility and cytocompatibility to endothelial cells than that of HF-treated sample. It was considered that the method of the present study can be used for the surface modification of the magnesium alloy to enhance the corrosion resistance and biocompatibility.

  15. Compatible Spatial Discretizations for Partial Differential Equations

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Douglas, N, ed.

    2004-11-25

    From May 11--15, 2004, the Institute for Mathematics and its Applications held a hot topics workshop on Compatible Spatial Discretizations for Partial Differential Equations. The numerical solution of partial differential equations (PDE) is a fundamental task in science and engineering. The goal of the workshop was to bring together a spectrum of scientists at the forefront of the research in the numerical solution of PDEs to discuss compatible spatial discretizations. We define compatible spatial discretizations as those that inherit or mimic fundamental properties of the PDE such as topology, conservation, symmetries, and positivity structures and maximum principles. A wide variety of discretization methods applied across a wide range of scientific and engineering applications have been designed to or found to inherit or mimic intrinsic spatial structure and reproduce fundamental properties of the solution of the continuous PDE model at the finite dimensional level. A profusion of such methods and concepts relevant to understanding them have been developed and explored: mixed finite element methods, mimetic finite differences, support operator methods, control volume methods, discrete differential forms, Whitney forms, conservative differencing, discrete Hodge operators, discrete Helmholtz decomposition, finite integration techniques, staggered grid and dual grid methods, etc. This workshop seeks to foster communication among the diverse groups of researchers designing, applying, and studying such methods as well as researchers involved in practical solution of large scale problems that may benefit from advancements in such discretizations; to help elucidate the relations between the different methods and concepts; and to generally advance our understanding in the area of compatible spatial discretization methods for PDE. Particular points of emphasis included: + Identification of intrinsic properties of PDE models that are critical for the fidelity of numerical

  16. Microvascular Blood Flow Improvement in Hyperglycemic Obese Adult Patients by Hypocaloric Diet.

    Science.gov (United States)

    Mastantuono, T; Di Maro, M; Chiurazzi, M; Battiloro, L; Starita, N; Nasti, G; Lapi, D; Iuppariello, L; Cesarelli, M; D'Addio, G; Colantuoni, A

    2016-11-01

    The present study was aimed to assess the changes in skin microvascular blood flow (SBF) in newly diagnosed hyperglycemic obese subjects, administered with hypocaloric diet. Adult patients were recruited and divided in three groups: NW group (n=54), NG (n=54) and HG (n=54) groups were constituted by normal weight, normoglycemic and hyperglycemic obese subjects, respectively. SBF was measured by laser Doppler perfusion monitoring technique and oscillations in blood flow were analyzed by spectral methods under baseline conditions, at 3 and 6 months of dietary treatment. Under resting conditions, SBF was lower in HG group than in NG and NW ones. Moreover, all subjects showed blood flow oscillations with several frequency components. In particular, hyperglycemic obese patients revealed lower spectral density in myogenic-related component than normoglycemic obese and normal weight ones. Moreover, post-occlusive reactive hyperemia (PORH) was impaired in hyperglycemic obese compared to normoglycemic and normal weigh subjects. After hypocaloric diet, in hyperglycemic obese patients there was an improvement in SBF accompanied by recovery in myogenic-related oscillations and arteriolar responses during PORH. In conclusion, hyperglycemia markedly affected peripheral microvascular function; hypocaloric diet ameliorated tissue blood flow.

  17. CMOS-compatible plenoptic detector for LED lighting applications.

    Science.gov (United States)

    Neumann, Alexander; Ghasemi, Javad; Nezhadbadeh, Shima; Nie, Xiangyu; Zarkesh-Ha, Payman; Brueck, S R J

    2015-09-07

    LED lighting systems with large color gamuts, with multiple LEDs spanning the visible spectrum, offer the potential of increased lighting efficiency, improved human health and productivity, and visible light communications addressing the explosive growth in wireless communications. The control of this "smart lighting system" requires a silicon-integrated-circuit-compatible, visible, plenoptic (angle and wavelength) detector. A detector element, based on an offset-grating-coupled dielectric waveguide structure and a silicon photodetector, is demonstrated with an angular resolution of less than 1° and a wavelength resolution of less than 5 nm.

  18. Mycelial compatibility groups and pathogenicity of Sclerotinia ...

    African Journals Online (AJOL)

    ... was determined by mycelial compatibility grouping (MCG) and isolate aggressiveness comparisons. MCG, host specificity and aggressiveness of S. sclerotiorum isolates were assessed. Isolate pairs were designated compatible when no barrage zone formed at sites of contact. They were designated incompatible when a ...

  19. Routine blood cultures in the management of pyelonephritis in pregnancy for improving outcomes.

    Science.gov (United States)

    Gomi, Harumi; Goto, Yoshihito; Laopaiboon, Malinee; Usui, Rie; Mori, Rintaro

    2015-02-13

    Pyelonephritis is a type of urinary tract infection (UTI) that affects the upper urinary tract and kidneys, and is one of the most common conditions for hospitalisation among pregnant women, aside from delivery. Samples of urine and blood are obtained and used for cultures as part of the diagnosis and management of the condition. Acute pyelonephritis requires hospitalisation with intravenous administration of antimicrobial agents. Several studies have questioned the necessity of obtaining blood cultures in addition to urine cultures, citing cost and questioning whether blood testing is superfluous. Pregnant women with bacteraemia require a change in the initial empirical treatment based on the blood culture. However, these cases are not common, and represent approximately 15% to 20% of cases. It is unclear whether blood cultures are essential for the effective management of the condition. To assess the effectiveness of routine blood cultures to improve health outcomes in the management of pyelonephritis in pregnant women. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register without language or date restrictions (31 December 2014). Randomised controlled trials and quasi-randomised trials comparing outcomes among pregnant women with pyelonephritis who received initial management with or without blood cultures. Cluster-randomised trials were eligible for inclusion in this review but none were identified. Clinical trials using a cross-over design were not eligible for inclusion. Two review authors independently assessed one trial report for inclusion. We identified one trial report but this was excluded. No clinical trials met the inclusion criteria for this review. There are no large-scale randomised controlled trials to assess outcomes in the management of pyelonephritis in pregnancy with or without blood cultures. Randomised controlled trials are needed to evaluate the effectiveness of managing pyelonephritis in pregnant women with or without

  20. Korean Red Ginseng Improves Blood Pressure Stability in Patients with Intradialytic Hypotension

    Directory of Open Access Journals (Sweden)

    I-Ju Chen

    2012-01-01

    Full Text Available Introduction. Intradialytic hypotension (IDH is a common complication during hemodialysis which may increase mortality risks. Low dose of Korean red ginseng (KRG has been reported to increase blood pressure. Whether KRG can improve hemodynamic stability during hemodialysis has not been examined. Methods. The 8-week study consisted of two phases: observation phase and active treatment phase. According to prehemodialysis blood pressure (BP, 38 patients with IDH were divided into group A (BP ≥ 140/90 mmHg, n = 18 and group B (BP < 140/90 mmHg, n = 20. Patients were instructed to chew 3.5 gm KRG slices at each hemodialysis session during the 4-week treatment phase. Blood pressure changes, number of sessions disturbed by symptomatic IDH, plasma levels of vasoconstrictors, blood biochemistry, and adverse effects were recorded. Results. KRG significantly reduced the degree of blood pressure drop during hemodialysis (P<0.05 and the frequency of symptomatic IDH (P<0.05. More activation of vasoconstrictors (endothelin-1 and angiotensin II during hemodialysis was found. The postdialytic levels of endothelin-1 and angiotensin II increased significantly (P<0.01. Conclusion. Chewing KRG renders IDH patients better resistance to acute BP reduction during hemodialysis via activation of vasoconstrictors. Our results suggest that KRG could be an adjuvant treatment for IDH.

  1. Albumin infusion improves renal blood flow autoregulation in patients with acute decompensation of cirrhosis and acute kidney injury.

    Science.gov (United States)

    Garcia-Martinez, Rita; Noiret, Lorette; Sen, Sambit; Mookerjee, Rajeshwar; Jalan, Rajiv

    2015-02-01

    In cirrhotic patients with renal failure, renal blood flow autoregulation curve is shifted to the right, which is consequent upon sympathetic nervous system activation and endothelial dysfunction. Albumin infusion improves renal function in cirrhosis by mechanisms that are incompletely understood. We aimed to determine the effect of albumin infusion on systemic haemodynamics, renal blood flow, renal function and endothelial function in patients with acute decompensation of cirrhosis and acute kidney injury. Twelve patients with refractory ascites and 10 patients with acute decompensation of cirrhosis and acute kidney injury were studied. Both groups were treated with intravenous albumin infusion, 40-60 g/days over 3-4 days. Cardiac and renal haemodynamics were measured. Endothelial activation/dysfunction was assessed using von Willebrand factor and serum nitrite levels. F2α Isoprostanes, resting neutrophil burst and noradrenaline levels were quantified as markers of oxidative stress, endotoxemia and sympathetic activation respectively. Albumin infusion leads to a shift in the renal blood flow autoregulation curve towards normalization, which resulted in a significant increase in renal blood flow. Accordingly, improvement of renal function was observed. In parallel, a significant decrease in sympathetic activation, inflammation/oxidative stress and endothelial activation/dysfunction was documented. Improvement of renal blood flow correlated with improvement in endothelial activation (r = 0.741, P renal function in acutely decompensated cirrhotic patients with acute kidney injury by impacting on renal blood flow autoregulation. This is possibly achieved through endothelial stabilization and a reduction in the sympathetic tone, endotoxemia and oxidative stress. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Effects of in-vehicle warning information displays with or without spatial compatibility on driving behaviors and response performance.

    Science.gov (United States)

    Liu, Yung-Ching; Jhuang, Jing-Wun

    2012-07-01

    A driving simulator study was conducted to evaluate the effects of five in-vehicle warning information displays upon drivers' emergent response and decision performance. These displays include visual display, auditory displays with and without spatial compatibility, hybrid displays in both visual and auditory format with and without spatial compatibility. Thirty volunteer drivers were recruited to perform various tasks that involved driving, stimulus-response, divided attention and stress rating. Results show that for displays of single-modality, drivers benefited more when coping with visual display of warning information than auditory display with or without spatial compatibility. However, auditory display with spatial compatibility significantly improved drivers' performance in reacting to the divided attention task and making accurate S-R task decision. Drivers' best performance results were obtained for hybrid display with spatial compatibility. Hybrid displays enabled drivers to respond the fastest and achieve the best accuracy in both S-R and divided attention tasks. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. 47 CFR 76.1622 - Consumer education program on compatibility.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Consumer education program on compatibility. 76... SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1622 Consumer education program on compatibility. Cable system operators shall provide a consumer education program on compatibility matters to...

  4. Automated typing of red blood cell and platelet antigens: a whole-genome sequencing study.

    Science.gov (United States)

    Lane, William J; Westhoff, Connie M; Gleadall, Nicholas S; Aguad, Maria; Smeland-Wagman, Robin; Vege, Sunitha; Simmons, Daimon P; Mah, Helen H; Lebo, Matthew S; Walter, Klaudia; Soranzo, Nicole; Di Angelantonio, Emanuele; Danesh, John; Roberts, David J; Watkins, Nick A; Ouwehand, Willem H; Butterworth, Adam S; Kaufman, Richard M; Rehm, Heidi L; Silberstein, Leslie E; Green, Robert C

    2018-06-01

    There are more than 300 known red blood cell (RBC) antigens and 33 platelet antigens that differ between individuals. Sensitisation to antigens is a serious complication that can occur in prenatal medicine and after blood transfusion, particularly for patients who require multiple transfusions. Although pre-transfusion compatibility testing largely relies on serological methods, reagents are not available for many antigens. Methods based on single-nucleotide polymorphism (SNP) arrays have been used, but typing for ABO and Rh-the most important blood groups-cannot be done with SNP typing alone. We aimed to develop a novel method based on whole-genome sequencing to identify RBC and platelet antigens. This whole-genome sequencing study is a subanalysis of data from patients in the whole-genome sequencing arm of the MedSeq Project randomised controlled trial (NCT01736566) with no measured patient outcomes. We created a database of molecular changes in RBC and platelet antigens and developed an automated antigen-typing algorithm based on whole-genome sequencing (bloodTyper). This algorithm was iteratively improved to address cis-trans haplotype ambiguities and homologous gene alignments. Whole-genome sequencing data from 110 MedSeq participants (30 × depth) were used to initially validate bloodTyper through comparison with conventional serology and SNP methods for typing of 38 RBC antigens in 12 blood-group systems and 22 human platelet antigens. bloodTyper was further validated with whole-genome sequencing data from 200 INTERVAL trial participants (15 × depth) with serological comparisons. We iteratively improved bloodTyper by comparing its typing results with conventional serological and SNP typing in three rounds of testing. The initial whole-genome sequencing typing algorithm was 99·5% concordant across the first 20 MedSeq genomes. Addressing discordances led to development of an improved algorithm that was 99·8% concordant for the remaining 90 Med

  5. Is Religious Education Compatible with Science Education?

    Science.gov (United States)

    Mahner, Martin; Bunge, Mario

    1996-01-01

    Addresses the problem of the compatibility of science and religion, and its bearing on science and religious education, challenges the popular view that science and religion are compatible or complementary. Discusses differences at the doctrinal, metaphysical, methodological, and attitudinal levels. Argues that religious education should be kept…

  6. 47 CFR 76.1621 - Equipment compatibility offer.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Equipment compatibility offer. 76.1621 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1621 Equipment compatibility offer. Cable system... offer to supply each subscriber with special equipment that will enable the simultaneous reception of...

  7. Multiparty Compatibility for Concurrent Objects

    Directory of Open Access Journals (Sweden)

    Roly Perera

    2016-06-01

    Full Text Available Objects and actors are communicating state machines, offering and consuming different services at different points in their lifecycle. Two complementary challenges arise when programming such systems. When objects interact, their state machines must be "compatible", so that services are requested only when they are available. Dually, when objects refine other objects, their state machines must be "compliant", so that services are honoured whenever they are promised. In this paper we show how the idea of multiparty compatibility from the session types literature can be applied to both of these problems. We present an untyped language in which concurrent objects are checked automatically for compatibility and compliance. For simple objects, checking can be exhaustive and has the feel of a type system. More complex objects can be partially validated via test cases, leading to a methodology closer to continuous testing. Our proof-of-concept implementation is limited in some important respects, but demonstrates the potential value of the approach and the relationship to existing software development practices.

  8. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

    Science.gov (United States)

    Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi

    2002-11-01

    We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.

  9. CD4+ LYMPHOCYTES IMPROVE VENOUS BLOOD FLOW IN EXPERIMENTAL ARTERIOVENOUS FISTULAE

    Science.gov (United States)

    Duque, Juan C.; Martinez, Laisel; Mesa, Annia; Wei, Yuntao; Tabbara, Marwan; Salman, Loay H.; Vazquez-Padron, Roberto I.

    2015-01-01

    Background The role of immune cells in arteriovenous fistulae (AVF) maturation is poorly understood and has received, until quite recently, little attention. This study examines the role of T lymphocytes in AVF vascular remodeling. Methods Experimental fistulae were created in athymic rnu nude rats lacking mature T lymphocytes and euthymic control animals by anastomosing the left superior epigastric vein to the nearby femoral artery. Blood flow rates, wall morphology and histological changes were assessed in AVF 21 days after creation. The effect of CD4+ lymphocytes on AVF maturation in athymic animals was analyzed by adoptive transfer of cells after fistula creation. Results The absence of T lymphocytes compromised blood flow in experimental fistulae. Histopathological inspection of AVF from athymic rats revealed that T cell immunodeficiency negatively affected venous vascular remodeling, as evidenced by a reduced lumen, a thick muscular layer and a low number of inflammatory cells compared to control animals. Adoptive transfer of CD4+ lymphocytes from euthymic rats into athymic animals before and after fistula creation improved blood flow and reduced intima-media thickness. Conclusion These results point at the protective role of CD4+ lymphocytes in the remodeling of the AVF vascular wall. PMID:25999254

  10. Kinematical Compatibility Conditions for Vorticity Across Shock Waves

    Science.gov (United States)

    Baty, Roy

    2015-11-01

    This work develops the general kinematical compatibility conditions for vorticity across arbitrary shock waves in compressible, inviscid fluids. The vorticity compatibility conditions are derived from the curl of the momentum equation using singular distributions defined on two-dimensional shock wave surfaces embedded in three-dimensional flow fields. The singular distributions are represented as generalized differential operators concentrated on moving shock wave surfaces. The derivation of the compatibility conditions for vorticity requires the application of second-order generalized derivatives and elementary tensor algebra. The well-known vorticity jump conditions across a shock wave are then shown to follow from the general kinematical compatibility conditions for vorticity by expressing the flow field velocity in vectorial components normal and tangential to a shock surface.

  11. Work efficiency improvement of >90% after implementation of an annual inpatient blood products administration consent form.

    Science.gov (United States)

    Lindsay, Holly; Bhar, Saleh; Bonifant, Challice; Sartain, Sarah; Whittle, Sarah B; Lee-Kim, Youngna; Shah, Mona D

    2018-01-01

    Paediatric haematology, oncology and bone marrow transplant (BMT) patients frequently require transfusion of blood products. Our institution required a new transfusion consent be obtained every admission. The objectives of this project were to: revise inpatient blood products consent form to be valid for 1 year, decrease provider time spent consenting from 15 to improve provider frustration with the consent process. Over 6 months, we determined the average number of hospitalisations requiring transfusions in a random sampling of haematology/oncology/BMT inpatients. We surveyed nurses and providers regarding frustration levels and contact required regarding consents. Four and 12 months after implementation of the annual consent, providers and nurses were resurveyed, and new inpatient cohorts were assessed. Comparison of preintervention and postintervention time data allowed calculation of provider time reduction, a surrogate measure of improved work efficiency. Prior to the annual consent, >33 hours were spent over 6 months obtaining consent on 40 patients, with >19 hours spent obtaining consent when no transfusions were administered during admission. Twelve months after annual consent implementation, 97.5% (39/40) of analysed patients had a completed annual blood products transfusion consent and provider work efficiency had improved by 94.6% (>30 hours). Although several surveyed variables improved following annual consent implementation, provider frustration with consent process remained 6 out of a max score of 10, the same level as prior to the intervention. Development of an annual inpatient blood products consent form decreased provider time from 15 to 90%.

  12. Compatibility of AlN ceramics with molten lithium

    Energy Technology Data Exchange (ETDEWEB)

    Yoneoka, Toshiaki; Sakurai, Toshiharu; Sato, Toshihiko; Tanaka, Satoru [Tokyo Univ., Department of Quantum Engineering and Systems Science, Tokyo (Japan)

    2002-04-01

    AlN ceramics were a candidate for electrically insulating materials and facing materials against molten breeder in a nuclear fusion reactor. In the nuclear fusion reactor, interactions of various structural materials with solid and liquid breeder materials as well as coolant materials are important. Therefore, corrosion tests of AlN ceramics with molten lithium were performed. AlN specimens of six kinds, different in sintering additives and manufacturing method, were used. AlN specimens were immersed into molten lithium at 823 K. Duration for the compatibility tests was about 2.8 Ms (32 days). Specimens with sintering additive of Y{sub 2}O{sub 3} by about 5 mass% formed the network structure of oxide in the crystals of AlN. It was considered that the corrosion proceeded by reduction of the oxide network and the penetration of molten lithium through the reduced pass of this network. For specimens without sintering additive, Al{sub 2}O{sub 3} containing by about 1.3% in raw material was converted to fine oxynitride particles on grain boundary or dissolved in AlN crystals. After immersion into lithium, these specimens were found to be sound in shape but reduced in electrical resistivity. These degradation of the two types specimens were considered to be caused by the reduction of oxygen components. On the other hand, a specimen sintered using CaO as sintering additive was finally became appreciably high purity. This specimen showed good compatibility for molten lithium at least up to 823 K. It was concluded that the reduction of oxygen concentration in AlN materials was essential in order to improve the compatibility for molten lithium. (author)

  13. Preparation, Cell Compatibility and Degradability of Collagen-Modified Poly(lactic acid

    Directory of Open Access Journals (Sweden)

    Miaomiao Cui

    2015-01-01

    Full Text Available Poly(lactic acid (PLA was modified using collagen through a grafting method to improve its biocompatibility and degradability. The carboxylic group at the open end of PLA was transferred into the reactive acylchlorided group by a reaction with phosphorus pentachloride. Then, collagen-modified PLA (collagen-PLA was prepared by the reaction between the reactive acylchlorided group and amino/hydroxyl groups on collagen. Subsequently, the structure of collagen-PLA was confirmed by Fourier transform infrared spectroscopy, fluorescein isothiocyanate-labeled fluorescence spectroscopy, X-ray photoelectron spectroscopy, and DSC analyses. Finally, some properties of collagen-PLA, such as hydrophilicity, cell compatibility and degradability were characterized. Results showed that collagen had been grafted onto the PLA with 5% graft ratio. Water contact angle and water absorption behavior tests indicated that the hydrophilicity of collagen-PLA was significantly higher than that of PLA. The cell compatibility of collagen-PLA with mouse embryonic fibroblasts (3T3 was also significantly better than PLA in terms of cell morphology and cell proliferation, and the degradability of PLA was also improved after introducing collagen. Results suggested that collagen-PLA was a promising candidate for biomedical applications.

  14. Studies on compatibility of energetic materials by thermal methods

    Directory of Open Access Journals (Sweden)

    Maria Alice Carvalho Mazzeu

    2010-04-01

    Full Text Available The chemical compatibility of explosives, pyrotechnics and propellants with those materials is studied to evaluate potential hazards when in contact with other materials during production, storage and handling. Compatibility can be studied by several thermal methods as DSC (differential scanning calorimetry, TG (Thermogravimetry, VST (Vacuum stability test and others. The test methods and well defined criteria are the most important elements when a compatibility study is being accomplished. In this paper, the compatibility of two very important high explosives used in ammunition, RDX (Cyclo-1,3,5-trimethylene-2,4,6-trinitramine and HMX (Cyclotetramethylene tetranitramine was studied with the materials: fluoroelastomer (Viton and powdered aluminum (Al, using DSC and VST methods. The criteria to judge the compatibility between materials is based on a standardization agreement (STANAG 4147, 2001, and the final conclusion is that explosives and this materials are compatible, but in DSC it was observed that the peak of decomposition temperature of the admixture of RDX with Al decreased in 3º C and another peak appeared after the decomposition peak.

  15. THE COMPATIBILITY STUDENT CHOICE OF UNIVERSITY MAJORING; A PRELIMINARY STUDIES

    Directory of Open Access Journals (Sweden)

    Daharnis Daharnis

    2016-06-01

    Full Text Available The continuous improvements in order to optimize the basic education to higher education are still running. Based on that purpose, there are many factors to supporting the students' learning activities success; one of the factors is suitability with majors in university. The purpose of this study is to reveal the condition of the compatibility of students majoring with their interest, then to describe the information when the student choose their majoring. Samples in this study were 122 peoples, taken by random sampling from the Padang State University. Data obtained by distributing questionnaires. The results showed that there are students that their major do not match with their interest (22.13%, only 3.28% of students who feel compatible with their major. This result should be a major concern, particularly for counselor in schools for design counseling services to solve these problems. The result of this study used as a grand tour or a preliminary study for further research.

  16. 钛基表面TiO2-HA生物陶瓷膜层的血液相容性研究%Blood Compatibility of TiO2-HA Bioceramic Coating on Titanium

    Institute of Scientific and Technical Information of China (English)

    徐琳; 丁建宁; 许晓静; 何远清; 雷小春

    2017-01-01

    采用微弧氧化法及微弧氧化-水热法对纯钛进行改性,制备了TiO2与TiO2-HA生物陶瓷膜层,通过溶血率实验、动态凝血时间实验和血小板黏附实验等方面评价其血液相容性.结果表明:各试样的溶血率都远小于5%,均符合医用材料的溶血率要求,不会产生溶血作用.与钛基TiO2生物陶瓷膜层和钛基材相比,钛基TiO2-HA生物陶瓷膜层的溶血率更低,动态凝血时间曲线变化更为缓慢,黏附的血小板更少,且变形程度更轻,具有更好的抑制血小板的聚集与变形的性能,血液相容性更优.%Biological surface modification of titanium was conducted by micro-arc oxidation (MAO) and hydrothermal synthesis (HS) methods to prepare TiO2 bioceramic coating and TiO2-HA bioceramic coating.The blood compatibility of modified coatings was evaluated by hemolysis rate test,dynamic clotting time and platelet adhesion test.The results demonstrate that hemolysis rates of all samples are less than 5%,and no hemolysis is observed.Compared with titanium and TiO2 bioceramic coating of titanium,TiO2-HA bioceramic coating of titanium exhibits better blood compatibility,with lower hemolysis rate,longer dynamic clotting time,fewer adhered platelets and slighter formation of platelets,which could better prevent platelet shape change and aggregation.

  17. Common Fixed Points for Weakly Compatible Maps

    Indian Academy of Sciences (India)

    The purpose of this paper is to prove a common fixed point theorem, from the class of compatible continuous maps to a larger class of maps having weakly compatible maps without appeal to continuity, which generalized the results of Jungck [3], Fisher [1], Kang and Kim [8], Jachymski [2], and Rhoades [9].

  18. Deformation compatibility control for engineering structures methods and applications

    CERN Document Server

    Zhu, Hanhua; Chen, Mengchong; Deng, Jianliang

    2017-01-01

    This book presents essential methods of deformation compatibility control, and explicitly addresses the implied conditions on the methods’ deformation compatibility. Consequently, these conditions can be considered in engineering structure design, while the conditions on stable equilibrium can be taken into account in the design method. Thus, the designed deformation and the actual deformation of the respective structure are approximately identical, guaranteeing both the flexibility of the construction material in force transmission and the equilibrium of force in the structure. Though equilibrium theory in engineering structures has been extensively studied, there has been comparatively little research on compatibility. In the limited researches available, the topics are primarily the theories and assumptions on the deformation compatibility, while few systematic works focus on the mechanical theoretical principles and methods of deformation compatibility control. As such, the flexibility of the constructi...

  19. Diabetes Support Groups Improve Patient’s Compliance and Control Blood Glucose Levels

    Directory of Open Access Journals (Sweden)

    Zamrotul Izzah

    2013-09-01

    Full Text Available Providing information is not enough to improve diabetic patient’s compliance and achieve goals of therapy. Patient’s good awareness as well as emotional and social supports from family and community may play an important role to improve their compliance and clinical outcomes. Therefore, diabetes support groups were developed and each support group consisted of two pharmacists, two nurses, diabetic patients and their family members. A total of 70 type 2 diabetic patient’s were enrolled and randomized into support group 1 and support group 2. Patients in the group 1 received information leaflets only, while patient in the group 2 received pharmacist counselling and information leaflets at each meeting. Patient’s awareness of diabetes and compliance with medications were assessed by a short questionnaire at baseline and final follow-up. Blood glucose and cholesterol levels were also evaluated in both groups. At the end of study, the overall patient’s awareness and compliance improved by 61.5%. The random and fasting blood glucose levels decreased over than 30% in the group 2 and around 14% in the group 1. This study reveals that collaboration between health care professionals and community in the diabetes support group might help diabetic patients to increase their knowledge and compliance with the diabetes therapy as well as glycaemic control.

  20. Radiation damage studies of detector-compatible Si JFETs

    International Nuclear Information System (INIS)

    Dalla Betta, Gian-Franco; Boscardin, Maurizio; Candelori, Andrea; Pancheri, Lucio; Piemonte, Claudio; Ratti, Lodovico; Zorzi, Nicola

    2007-01-01

    We have largely improved the performance of our detector-compatible Si JFETs by optimizing the fabrication technology. New devices feature thermal noise values close to the theoretical ones, and remarkably low 1/f noise figures. In view of adopting these JFETs for X-ray imaging and HEP applications, bulk and surface radiation damage tests have been carried out by irradiating single transistors and test structures with neutrons and X-rays. Selected results from static and noise characterization of irradiated devices are discussed in this paper, and the impact of radiation effects on the performance of JFET-based circuits is addressed

  1. Home blood pressure monitoring, secure electronic messaging and medication intensification for improving hypertension control: a mediation analysis.

    Science.gov (United States)

    Ralston, J D; Cook, A J; Anderson, M L; Catz, S L; Fishman, P A; Carlson, J; Johnson, R; Green, B B

    2014-01-01

    We evaluated the role of home monitoring, communication with pharmacists, medication intensification, medication adherence and lifestyle factors in contributing to the effectiveness of an intervention to improve blood pressure control in patients with uncontrolled essential hypertension. We performed a mediation analysis of a published randomized trial based on the Chronic Care Model delivered over a secure patient website from June 2005 to December 2007. Study arms analyzed included usual care with a home blood pressure monitor and usual care with home blood pressure monitor and web-based pharmacist care. Mediator measures included secure messaging and telephone encounters; home blood pressure monitoring; medications intensification and adherence and lifestyle factors. Overall fidelity to the Chronic Care Model was assessed with the Patient Assessment of Chronic Care (PACIC) instrument. The primary outcome was percent of participants with blood pressure (BP) <140/90 mm Hg. At 12 months follow-up, patients in the web-based pharmacist care group were more likely to have BP <140/90 mm Hg (55%) compared to patients in the group with home blood pressure monitors only (37%) (p = 0.001). Home blood pressure monitoring accounted for 30.3% of the intervention effect, secure electronic messaging accounted for 96%, and medication intensification for 29.3%. Medication adherence and self-report of fruit and vegetable intake and weight change were not different between the two study groups. The PACIC score accounted for 22.0 % of the main intervention effect. The effect of web-based pharmacist care on improved blood pressure control was explained in part through a combination of home blood pressure monitoring, secure messaging, and antihypertensive medication intensification.

  2. Air quality improvement during 2010 Asian games on blood coagulability in COPD patients.

    Science.gov (United States)

    Zhang, Zili; Wang, Jian; Guo, Meihua; Xiong, Mingmei; Zhou, Qipeng; Li, Defu; Shu, Jiaze; Lu, Wenju; Sun, Dejun

    2016-04-01

    Exposure to elevated levels of ambient air pollutants can lead to adverse cardiovascular effects. Perturbation of the coagulation balance is one of the potential mechanisms. However, evidence regarding the impact of improvement in air pollution on blood coagulability in COPD patients has never been reported. Coagulation processes are known to be of relevance for cardiovascular pathology; therefore, this study aimed to investigate the association of short-term air pollution exposure with blood marker (D-dimer) of coagulation. A 3-year (through the Asian game) cohort study based on the GIRD COPD Biobank Project was conducted in 36 COPD patients to estimate whether changes in measurements of D-dimer were associated with changes in pollutant concentration, comparing for 51 intervention days (November 1-December 21) in 2010 with the same calendar date of baseline years (2009 and 2011). Daily mean concentrations of air pollutants and meteorological variables were measured during the time. Daily PM10 decreased from 65.86 μg/m(3) during the baseline period to 62.63 μg/m(3) during the Asian Games period; daily NO2 decreased from 51.33 to 42.63 μg/m(3). SO2 and other weather variables did not differ substantially. We did not observe statistically significant improvements in D-dimer levels by 9.86% from a pre-Asian game mean of 917 ng/ml to a during-Asian game mean of 1007 ng/ml, platelet number by 11.66%, PH by -0.15%, PCO2 by -6.54%, and PO2 by -1.16%. In the post-Asian game period, when pollutant concentrations increased, most outcomes approximated pre-Asian game levels, and similar effects were also demonstrated in D-dimer, platelet number, and arterial blood gas. For D-dimer and platelet number, we observed statistically significant increases associated with increases in NO2 at lag 1-3 and SO2 at lag 2-4. For PH, PCO2, and PO2, any significant effect was not demonstrated. This study gives no support to the hypothesis that reduction in air pollution levels during the

  3. Research on micro-structure and hemo-compatibility of the artificial heart valve surface

    International Nuclear Information System (INIS)

    Ye Xia; Shao Yunliang; Zhou Ming; Li Jian; Cai Lan

    2009-01-01

    In order to seek the method to improve the hemo-compatibility of artificial mechanical heart valve, the surface of rabbit's heart valve was observed using the scanning electron microscopy (SEM). The results showed that the dual-scale structure which consists of cobblestones-like structure of 8 μm in underside diameter and 3 μm in height, and the fine cilia of about 150 nm in diameter, was helpful to the hemo-compatibility of the heart valve. Therefore, the polydimethylsiloxane (PDMS) surface with hierarchical micro-structure was fabricated using femtosecond laser fabrication technique and soft lithography. At the same time, the tests of apparent contact angle and platelet adhesion on both smooth and textured PDMS surfaces were carried out to study their wettability and hemo-compatibility. The results demonstrated that the surface with textured structure displayed more excellent wettabililty and anti-coagulation property than that of smooth surface. The apparent contact angle of textured surface enhanced from 113.1 deg. to 163.6 deg. and the amount of adsorbed platelet on such surface was fewer, no distortion and no activation were found.

  4. Improved calculation of the equilibrium magnetization of arterial blood in arterial spin labeling

    DEFF Research Database (Denmark)

    Ahlgren, André; Wirestam, Ronnie; Knutsson, Linda

    2018-01-01

    PURPOSE: To propose and assess an improved method for calculating the equilibrium magnetization of arterial blood ( M0a), used for calibration of perfusion estimates in arterial spin labeling. METHODS: Whereas standard M0a calculation is based on dividing a proton density-weighted image by an ave...

  5. [Work organisation improvement methods applied to activities of Blood Transfusion Establishments (BTE): Lean Manufacturing, VSM, 5S].

    Science.gov (United States)

    Bertholey, F; Bourniquel, P; Rivery, E; Coudurier, N; Follea, G

    2009-05-01

    Continuous improvement of efficiency as well as new expectations from customers (quality and safety of blood products) and employees (working conditions) imply constant efforts in Blood Transfusion Establishments (BTE) to improve work organisations. The Lean method (from "Lean" meaning "thin") aims at identifying wastages in the process (overproduction, waiting, over-processing, inventory, transport, motion) and then reducing them in establishing a mapping of value chain (Value Stream Mapping). It consists in determining the added value of each step of the process from a customer perspective. Lean also consists in standardizing operations while implicating and responsabilizing all collaborators. The name 5S comes from the first letter of five operations of a Japanese management technique: to clear, rank, keep clean, standardize, make durable. The 5S method leads to develop the team working inducing an evolution of the way in the management is performed. The Lean VSM method has been applied to blood processing (component laboratory) in the Pays de la Loire BTE. The Lean 5S method has been applied to blood processing, quality control, purchasing, warehouse, human resources and quality assurance in the Rhône-Alpes BTE. The experience returns from both BTE shows that these methods allowed improving: (1) the processes and working conditions from a quality perspective, (2) the staff satisfaction, (3) the efficiency. These experiences, implemented in two BTE for different processes, confirm the applicability and usefulness of these methods to improve working organisations in BTE.

  6. Compatibility of cars in The Netherlands : statistical analysis of frontal collisions in the framework of the European research project "Improvement of crash compatibility between cars", Workpackage 2a, project funded by the European Commission DGVII under the Transport RTD Programme.

    NARCIS (Netherlands)

    Kampen, L.T. van

    2000-01-01

    In this study, compatibility is defined as the capability of vehicles to protect both their own occupants and occupants of opponent vehicles during crashes. Vehicles are called compatible when they offer equal amounts of protection to both their own occupants and to occupants of crash-opponent

  7. Improved instrumentation for blood flow velocity measurements in the microcirculation of small animals

    International Nuclear Information System (INIS)

    Mesquita, Jayme Alves Jr. de; Bouskela, Eliete; Wajnberg, Eliane; Lopes de Melo, Pedro

    2007-01-01

    Microcirculation is the generic name of vessels with internal diameter less than 100 μm of the circulatory system, whose main functions are tissue nutrition and oxygen supply. In microcirculatory studies, it is important to know the amount of oxyhemoglobin present in the blood and how fast it is moving. The present work describes improvements introduced in a classical hardware-based instrument that has usually been used to monitor blood flow velocity in the microcirculation of small animals. It consists of a virtual instrument that can be easily incorporated into existing hardware-based systems, contributing to reduce operator related biases and allowing digital processing and storage. The design and calibration of the modified instrument are described as well as in vitro and in vivo results obtained with electrical models and small animals, respectively. Results obtained in in vivo studies showed that this new system is able to detect a small reduction in blood flow velocity comparing arteries and arterioles (p<0.002) and a further reduction in capillaries (p<0.0001). A significant increase in velocity comparing capillaries and venules (p<0.001) and venules and veins (p<0.001) was also observed. These results are in close agreement with biophysical principles. Moreover, the improvements introduced in the device allowed us to clearly observe changes in blood flow introduced by a pharmacological intervention, suggesting that the system has enough temporal resolution to track these microcirculatory events. These results were also in close conformity to physiology, confirming the high scientific potential of the modified system and indicating that this instrument can also be useful for pharmacological evaluations

  8. Compatible bacterial mixture, tolerant to desiccation, improves maize plant growth.

    Science.gov (United States)

    Molina-Romero, Dalia; Baez, Antonino; Quintero-Hernández, Verónica; Castañeda-Lucio, Miguel; Fuentes-Ramírez, Luis Ernesto; Bustillos-Cristales, María Del Rocío; Rodríguez-Andrade, Osvaldo; Morales-García, Yolanda Elizabeth; Munive, Antonio; Muñoz-Rojas, Jesús

    2017-01-01

    Plant growth-promoting rhizobacteria (PGPR) increase plant growth and crop productivity. The inoculation of plants with a bacterial mixture (consortium) apparently provides greater benefits to plant growth than inoculation with a single bacterial strain. In the present work, a bacterial consortium was formulated containing four compatible and desiccation-tolerant strains with potential as PGPR. The formulation had one moderately (Pseudomonas putida KT2440) and three highly desiccation-tolerant (Sphingomonas sp. OF178, Azospirillum brasilense Sp7 and Acinetobacter sp. EMM02) strains. The four bacterial strains were able to adhere to seeds and colonize the rhizosphere of plants when applied in both mono-inoculation and multi-inoculation treatments, showing that they can also coexist without antagonistic effects in association with plants. The effects of the bacterial consortium on the growth of blue maize were evaluated. Seeds inoculated with either individual bacterial strains or the bacterial consortium were subjected to two experimental conditions before sowing: normal hydration or desiccation. In general, inoculation with the bacterial consortium increased the shoot and root dry weight, plant height and plant diameter compared to the non-inoculated control or mono-inoculation treatments. The bacterial consortium formulated in this work had greater benefits for blue maize plants even when the inoculated seeds underwent desiccation stress before germination, making this formulation attractive for future field applications.

  9. Compatible bacterial mixture, tolerant to desiccation, improves maize plant growth.

    Directory of Open Access Journals (Sweden)

    Dalia Molina-Romero

    Full Text Available Plant growth-promoting rhizobacteria (PGPR increase plant growth and crop productivity. The inoculation of plants with a bacterial mixture (consortium apparently provides greater benefits to plant growth than inoculation with a single bacterial strain. In the present work, a bacterial consortium was formulated containing four compatible and desiccation-tolerant strains with potential as PGPR. The formulation had one moderately (Pseudomonas putida KT2440 and three highly desiccation-tolerant (Sphingomonas sp. OF178, Azospirillum brasilense Sp7 and Acinetobacter sp. EMM02 strains. The four bacterial strains were able to adhere to seeds and colonize the rhizosphere of plants when applied in both mono-inoculation and multi-inoculation treatments, showing that they can also coexist without antagonistic effects in association with plants. The effects of the bacterial consortium on the growth of blue maize were evaluated. Seeds inoculated with either individual bacterial strains or the bacterial consortium were subjected to two experimental conditions before sowing: normal hydration or desiccation. In general, inoculation with the bacterial consortium increased the shoot and root dry weight, plant height and plant diameter compared to the non-inoculated control or mono-inoculation treatments. The bacterial consortium formulated in this work had greater benefits for blue maize plants even when the inoculated seeds underwent desiccation stress before germination, making this formulation attractive for future field applications.

  10. Preformulation compatibility screening of dika fat-drug mixtures ...

    African Journals Online (AJOL)

    Differential scanning calorimetry (DSC) was used as screening technique for assessing compatibility between dika fat and drug substances. Dika fat was found to be compatible with aspirin, ascorbic acid, paracetamol, sulphanilamide, phenylpropanolamine hydrochloride, bromopheniramine maleate, chlorpheniramire ...

  11. Application of remote handling compatibility on ITER plant

    International Nuclear Information System (INIS)

    Sanders, S.; Rolfe, A.; Mills, S.F.; Tesini, A.

    2011-01-01

    The ITER plant will require fully remote maintenance during its operational life. For this to be effective, safe and efficient the plant will have to be developed in accordance with remote handling (RH) compatibility requirements. A system for ensuring RH compatibility on plant designed for Tokamaks was successfully developed and applied, inter alia, by the authors when working at the JET project. The experience gained in assuring RH compatibility of plant at JET is now being applied to RH relevant ITER plant. The methodologies required to ensure RH compatibility of plant include the standardization of common plant items, standardization of RH features, availability of common guidance on RH best practice and a protocol for design and interface review and approval. The protocol in use at ITER is covered by the ITER Remote Maintenance Management System (IRMMS) defines the processes and utilization of management controls including Plant Definition Forms (PDF), Task Definition Forms (TDFs) and RH Compatibility Assessment Forms (RHCA) and the ITER RH Code of Practice. This paper will describe specific examples where the authors have applied the methodology proven at JET to ensure remote handling compatibility on ITER plant. Examples studied are: ·ELM coils (to be installed in-vessel behind the Blanket Modules) - handling both in-vessel, in Casks and at the Hot Cell as well as fully remote installation and connection (mechanical and electrical) in-vessel. ·Neutral beam systems (in-vessel and in the NB Cell) - beam sources, cesium oven, beam line components (accessed in the NB Cell) and Duct Liner (remotely replaced from in-vessel). ·Divertor (in-vessel) - cooling pipe work and remotely operated electrical connector. The RH compatibility process can significantly affect plant design. This paper should therefore be of interest to all parties who develop ITER plant designs.

  12. A novel method of selective removal of human DNA improves PCR sensitivity for detection of Salmonella Typhi in blood samples.

    Science.gov (United States)

    Zhou, Liqing; Pollard, Andrew J

    2012-07-27

    Enteric fever is a major public health problem, causing an estimated 21million new cases and 216,000 or more deaths every year. Current diagnosis of the disease is inadequate. Blood culture only identifies 45 to 70% of the cases and is time-consuming. Serological tests have very low sensitivity and specificity. Clinical samples obtained for diagnosis of enteric fever in the field generally have blood, so that even PCR-based methods, widely used for detection of other infectious diseases, are not a straightforward option in typhoid diagnosis. We developed a novel method to enrich target bacterial DNA by selective removal of human DNA from blood samples, enhancing the sensitivity of PCR tests. This method offers the possibility of improving PCR assays directly using clinical specimens for diagnosis of this globally important infectious disease. Blood samples were mixed with ox bile for selective lysis of human blood cells and the released human DNA was then digested with addition of bile resistant micrococcal nuclease. The intact Salmonella Typhi bacteria were collected from the specimen by centrifugation and the DNA extracted with QIAamp DNA mini kit. The presence of Salmonella Typhi bacteria in blood samples was detected by PCR with the fliC-d gene of Salmonella Typhi as the target. Micrococcal nuclease retained activity against human blood DNA in the presence of up to 9% ox bile. Background human DNA was dramatically removed from blood samples through the use of ox bile lysis and micrococcal nuclease for removal of mammalian DNA. Consequently target Salmonella Typhi DNA was enriched in DNA preparations and the PCR sensitivity for detection of Salmonella Typhi in spiked blood samples was enhanced by 1,000 fold. Use of a combination of selective ox-bile blood cell lysis and removal of human DNA with micrococcal nuclease significantly improves PCR sensitivity and offers a better option for improved typhoid PCR assays directly using clinical specimens in diagnosis of

  13. Multi-disciplinary System Engineering and the Compatibility Modeling Language (UCML

    Directory of Open Access Journals (Sweden)

    Carolin Eckl

    2009-04-01

    Full Text Available Over time, technical systems such as automobiles or spacecraft have grown more complex due to the incorporation of increasingly more and different components. The integration of these components, which are frequently designed and constructed within separate departments and companies may lead to malfunctioning systems as their interplay cannot be tested within the earlier phases of development. This paper introduces compatibility management as one solution to the problems of late component integration. Compatibility management is carried out on a common crossdomain model of the system and therefore allows to test compatibility early on. We show how compatibility management can be embedded into the phased development of ECSS-M-30A and present the (Unified Compatibility Modeling Language ((UCML, which is used for the underlying cross-domain model. A case study demonstrates the application of (UCML in the development of a small satellite and explains different degrees of compatibility.

  14. Improving left ventricular segmentation in four-dimensional flow MRI using intramodality image registration for cardiac blood flow analysis.

    Science.gov (United States)

    Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino

    2018-01-01

    Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P  0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Elements of a compatible optimization theory for coupled systems; Elements d'une theorie de l'optimisation compatible de systemes couples

    Energy Technology Data Exchange (ETDEWEB)

    Bonnemay, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The first theory deals with the compatible optimization in coupled systems. A game theory for two players and with a non-zero sum is first developed. The conclusions are then extended to the case of a game with any finite number of players. After this essentially static study, the dynamic aspect of the problem is applied to the case of games which evolve. By applying PONTRYAGIN maximum principle it is possible to derive a compatible optimisation theorem which constitutes a necessary condition. (author) [French] La premiere these traite de l'optimalisation compatible des systemes couples. Une theorie du jeu a deux joueurs et a somme non nulle est d'abord developpee. Ses conclusions sont etendues ensuite au jeu a un nombre fini quelconque de joueurs. Apres cette etude essentiellement statique, l'aspect dynamique du probleme est introduit dans les jeux evolutifs. L'application du principe du maximum de PONTRYAGIN permet d'enoncer un theoreme d'optimalite compatible qui constitue une condition necessaire. (auteur)

  16. Fully CMOS-compatible titanium nitride nanoantennas

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Justin A., E-mail: jabriggs@stanford.edu [Department of Applied Physics, Stanford University, 348 Via Pueblo Mall, Stanford, California 94305 (United States); Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, California 94305 (United States); Naik, Gururaj V.; Baum, Brian K.; Dionne, Jennifer A. [Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, California 94305 (United States); Petach, Trevor A.; Goldhaber-Gordon, David [Department of Physics, Stanford University, 382 Via Pueblo Mall, Stanford, California 94305 (United States)

    2016-02-01

    CMOS-compatible fabrication of plasmonic materials and devices will accelerate the development of integrated nanophotonics for information processing applications. Using low-temperature plasma-enhanced atomic layer deposition (PEALD), we develop a recipe for fully CMOS-compatible titanium nitride (TiN) that is plasmonic in the visible and near infrared. Films are grown on silicon, silicon dioxide, and epitaxially on magnesium oxide substrates. By optimizing the plasma exposure per growth cycle during PEALD, carbon and oxygen contamination are reduced, lowering undesirable loss. We use electron beam lithography to pattern TiN nanopillars with varying diameters on silicon in large-area arrays. In the first reported single-particle measurements on plasmonic TiN, we demonstrate size-tunable darkfield scattering spectroscopy in the visible and near infrared regimes. The optical properties of this CMOS-compatible material, combined with its high melting temperature and mechanical durability, comprise a step towards fully CMOS-integrated nanophotonic information processing.

  17. New Commitment Options: Compatibility with Emissions Trading

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This paper considers different options for quantitative greenhouse gas emission commitments from the standpoint of their technical compatibility with emissions trading. These are dynamic targets, binding targets with price caps, non-binding targets, sector-wide targets/mechanisms, action targets, allowances and endowments, and long-term permits. This paper considers these options from the standpoint of their compatibility with emissions trading.

  18. Detergent-compatible proteases: microbial production, properties, and stain removal analysis.

    Science.gov (United States)

    Niyonzima, Francois Niyongabo; More, Sunil

    2015-01-01

    Proteases are one of the most important commercial enzymes used in various industrial domains such as detergent and leather industries. The alkaline proteases as well as other detergent-compatible enzymes such as lipases and amylases serve now as the key components in detergent formulations. They break down various stains during fabric washing. The search for detergent-compatible proteases with better properties is a continuous exercise. The current trend is to use detergent-compatible proteases that are stable over a wide temperature range. Although the proteases showing stability at elevated pH have the capacity to be used in detergent formulations, their usage can be significant if they are also stable and compatible with detergent and detergent ingredients, and also able to remove protein stains. Despite the existence of some reviews on alkaline proteases, there is no specification for the use of alkaline proteases as detergent additives. The present review describes the detergent-compatible proteases tested as detergent additives. An overview was provided for screening, optimization, purification, and properties of detergent compatible proteases, with an emphasis on the stability and compatibility of the alkaline proteases with the detergent and detergent compounds, as well as stain removal examination methods.

  19. Compatibility Grab Sampling and Analysis Plan for FY 2000

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    1999-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for grab samples obtained to address waste compatibility. It is written in accordance with requirements identified in Data Quality Objectives for Tank Farms Waste Compatibility Program (Mulkey et al. 1999) and Tank Farm Waste Transfer Compatibility Program (Fowler 1999). In addition to analyses to support Compatibility, the Waste Feed Delivery program has requested that tank samples obtained for Compatibility also be analyzed to confirm the high-level waste and/or low-activity waste envelope(s) for the tank waste (Baldwin 1999). The analytical requirements to confirm waste envelopes are identified in Data Quality Objectives for TWRS Privatization Phase I: Confirm Tank T is an Appropriate Feed Source for Low-Activity Waste Feed Batch X (Nguyen 1999a) and Data Quality Objectives for RPP Privatization Phase I: Confirm Tank T is an Appropriate Feed Source for High-Level Waste Feed Batch X (Nguyen 1999b)

  20. Compatibility and testing of electronic components

    CERN Document Server

    Jowett, C E

    2013-01-01

    Compatibility and Testing of Electronic Components outlines the concepts of component part life according to thresholds of failure; the advantages that result from identifying such thresholds; their identification; and the various tests used in their detection. The book covers topics such as the interconnection of miniature passive components; the integrated circuit compatibility and its components; the semiconductor joining techniques; and the thin film hybrid approach in integrated circuits. Also covered are topics such as thick film resistors, conductors, and insulators; thin inlays for el

  1. A technology-supported collaboration between a health plan and a community pharmacy to improve blood pressure control.

    Science.gov (United States)

    Frail, Caitlin K; Cooper, Susan; Gallagher, Tim; Sarkis, Josh; Topor, Laura; Bruzek, Richard J

    To assess the impact of a health plan and community pharmacy partnership to improve blood pressure control. A midwestern health plan and a regional community pharmacy chain. Health plan members with a hypertension diagnosis and attributed to the pharmacy chain based on prescription claims were invited to participate. Interested patients enrolled in the program at their pharmacies and were assigned a "smart card" for use with a blood pressure kiosk in the pharmacy. When the card was used at the kiosk, individual patient readings were linked directly to their electronic pharmacy record and an online patient portal. Pharmacists intervened with patients and prescribers as necessary to address adherence issues and adjust therapy as needed. Before and after blood pressure readings were assessed to determine the impact of patient self-monitoring and pharmacist intervention for patients with 1) uncontrolled blood pressure at first reading and 2) multiple readings throughout the pilot period. Fifty-six of 276 eligible patients (20%) were enrolled in the program. Fourteen patients qualified for before and after assessments, having uncontrolled blood pressure on initial reading and multiple readings throughout the pilot. These patients demonstrated a mean reduction in systolic blood pressure of 12 mm Hg and diastolic blood pressure of 8 mm Hg. Nine of 16 eligible pharmacy locations enrolled patients at their sites. Challenges faced in the initiative included gaining adequate pharmacist and patient engagement. The pilot demonstrated promising early results in a model that has potential to improve blood pressure monitoring and management in a community pharmacy setting. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  2. Generate tri-directional spectra-compatible time histories using HHT method

    Energy Technology Data Exchange (ETDEWEB)

    Li, Bo; Xie, Wei-Chau, E-mail: xie@uwaterloo.ca; Pandey, Mahesh D.

    2016-11-15

    Highlights: • Hilbert–Huang Transform are applied to modify real earthquake records. • Generate tri-directional time histories compatible with target spectra. • Both GRS and FRS are considered as target spectra. • Target spectra with multiple damping ratios are considered. - Abstract: This paper proposes two algorithms to generate spectrum-compatible time histories based on two approaches recommended by USNRC Standard Review Plan 3.7.1. Hilbert–Huang Transform technique is used to analyze frequency contents and amplitudes of seed motions. Through adjusting the frequency contents and amplitudes of seed motions, spectrum-compatible time histories are obtained. The first algorithm is to generate tri-directional time histories compatible with multi-damping target design spectra (ground response spectra or floor response spectra). The second algorithm is to generate tri-directional time histories compatible with single-damping target design spectra. Examples are presented to demonstrate versatility of these two proposed algorithms to generate spectra-compatible time histories.

  3. Generate tri-directional spectra-compatible time histories using HHT method

    International Nuclear Information System (INIS)

    Li, Bo; Xie, Wei-Chau; Pandey, Mahesh D.

    2016-01-01

    Highlights: • Hilbert–Huang Transform are applied to modify real earthquake records. • Generate tri-directional time histories compatible with target spectra. • Both GRS and FRS are considered as target spectra. • Target spectra with multiple damping ratios are considered. - Abstract: This paper proposes two algorithms to generate spectrum-compatible time histories based on two approaches recommended by USNRC Standard Review Plan 3.7.1. Hilbert–Huang Transform technique is used to analyze frequency contents and amplitudes of seed motions. Through adjusting the frequency contents and amplitudes of seed motions, spectrum-compatible time histories are obtained. The first algorithm is to generate tri-directional time histories compatible with multi-damping target design spectra (ground response spectra or floor response spectra). The second algorithm is to generate tri-directional time histories compatible with single-damping target design spectra. Examples are presented to demonstrate versatility of these two proposed algorithms to generate spectra-compatible time histories.

  4. Improving engraftment and immune reconstitution in umbilical cord blood transplantation

    Directory of Open Access Journals (Sweden)

    Robert eDanby

    2014-02-01

    Full Text Available Umbilical cord blood (UCB is an important source of haematopoietic stem cells (HSC for allogeneic transplantation when HLA-matched sibling and unrelated donors (MUD are unavailable. Although the overall survival rates of UCB transplantation are comparable to the results with MUD, UCB transplants are associated with slow engraftment, delayed immune reconstitution, and increased opportunistic infections. While this may be a consequence of the lower cell dose in UCB grafts, it also reflects the relative immaturity of cellular immunity within cord blood. Furthermore, the limited number of cells and the non-availability of donor lymphocyte infusions (DLI currently prevent the use of post-transplant cellular immunotherapy to boost donor-derived immunity to treat infection, mixed chimerism and disease relapse. Therefore, to further develop UCB transplantation, many strategies to enhance engraftment and immune reconstitution are currently under investigation. This review summarises our current understanding of engraftment and immune recovery following UCB transplantation and why this differs from allogeneic transplants using other sources of HSC. It also provides an comprehensive overview of the promising techniques being used to improve myeloid and lymphoid recovery, including expansion, homing, and delivery of UCB HSC; combined use of UCB with third party donors; isolation and expansion of NK cells, pathogen specific T cells, and regulatory T cells; methods to protect and/or improve thymopoiesis. As many of these strategies are now in clinical trials, it is anticipated that UCB transplantation will continue to advance, further expanding our understanding of UCB biology and HSC transplantation.

  5. Interaction of different forms of graphene with chicken embryo red blood cells

    DEFF Research Database (Denmark)

    Jaworski, S.; Hinzmann, Mateusz; Sawosz, Ewa

    2017-01-01

    , while others have indicated that graphene might become health hazards. In this study, we explore the biocompatibility of graphene-related materials with chicken embryo red blood cells (RBC). The hemolysis assay was employed to evaluate the in vitro blood compatibility of reduced graphene, graphene oxide......, and reduced graphene oxide, because these materials have recently been used for biomedical applications, including injectable graphene-related particles. This study investigated structural damage, ROS production and hemolysis of chicken embryo red blood cells. Different forms of graphene, when incubated...... with chicken embryo RBC, were harmful to cell structure and induced hemolysis....

  6. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    Science.gov (United States)

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A 31-channel MR brain array coil compatible with positron emission tomography.

    Science.gov (United States)

    Sander, Christin Y; Keil, Boris; Chonde, Daniel B; Rosen, Bruce R; Catana, Ciprian; Wald, Lawrence L

    2015-06-01

    Simultaneous acquisition of MR and positron emission tomography (PET) images requires the placement of the MR detection coil inside the PET detector ring where it absorbs and scatters photons. This constraint is the principal barrier to achieving optimum sensitivity on each modality. Here, we present a 31-channel PET-compatible brain array coil with reduced attenuation but improved MR sensitivity. A series of component tests were performed to identify tradeoffs between PET and MR performance. Aspects studied include the remote positioning of preamplifiers, coax size, coil trace size/material, and plastic housing. We then maximized PET performance at minimal cost to MR sensitivity. The coil was evaluated for MR performance (signal to noise ratio [SNR], g-factor) and PET attenuation. The coil design showed an improvement in attenuation by 190% (average) compared with conventional 32-channel arrays, and no loss in MR SNR. Moreover, the 31-channel coil displayed an SNR improvement of 230% (cortical region of interest) compared with a PET-optimized 8-channel array with similar attenuation properties. Implementing attenuation correction of the 31-channel array successfully removed PET artifacts, which were comparable to those of the 8-channel array. The design of the 31-channel PET-compatible coil enables higher sensitivity for PET/MR imaging, paving the way for novel applications in this hybrid-imaging domain. © 2014 Wiley Periodicals, Inc.

  8. Fertilization compatibility of spawning corals

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes experimental results of fertilization assays to characterize genetic compatibility between individual parental genotypes. Targeted species...

  9. An Improved method for separation of leucocytes from peripheral blood of the little skate (Leucoraja erinacea)

    Science.gov (United States)

    Tomana, Mitsuru; Parton, Angela; Barnes, David W.

    2008-01-01

    Cartilaginous fish, especially sharks, rays and skates (elasmobranchs) hold interest as comparative models in immunology because they are thought to be among the organisms most closely related to the ancestor animal that first developed acquired immunity. The aim of this study was to improve methods used for the purification of viable leucocytes from peripheral blood of elasmobranchs. Here we describe modifications of density gradient centrifugation and medium formulation that improve isolation and analysis of highly-purified leucocytes from peripheral blood of a model elasmobranch, Leucoraja erinacea, the little skate. These techniques contribute to the preparation of elasmobranch immune cells that can be reliably analyzed by a variety of means, including the study of immune function. PMID:18474431

  10. [Innovative technology and blood safety].

    Science.gov (United States)

    Begue, S; Morel, P; Djoudi, R

    2016-11-01

    If technological innovations are not enough alone to improve blood safety, their contributions for several decades in blood transfusion are major. The improvement of blood donation (new apheresis devices, RFID) or blood components (additive solutions, pathogen reduction technology, automated processing of platelets concentrates) or manufacturing process of these products (by automated processing of whole blood), all these steps where technological innovations were implemented, lead us to better traceability, more efficient processes, quality improvement of blood products and therefore increased blood safety for blood donors and patients. If we are on the threshold of a great change with the progress of pathogen reduction technology (for whole blood and red blood cells), we hope to see production of ex vivo red blood cells or platelets who are real and who open new conceptual paths on blood safety. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Compatibility of Segments of Thermoelectric Generators

    Science.gov (United States)

    Snyder, G. Jeffrey; Ursell, Tristan

    2009-01-01

    A method of calculating (usually for the purpose of maximizing) the power-conversion efficiency of a segmented thermoelectric generator is based on equations derived from the fundamental equations of thermoelectricity. Because it is directly traceable to first principles, the method provides physical explanations in addition to predictions of phenomena involved in segmentation. In comparison with the finite-element method used heretofore to predict (without being able to explain) the behavior of a segmented thermoelectric generator, this method is much simpler to implement in practice: in particular, the efficiency of a segmented thermoelectric generator can be estimated by evaluating equations using only hand-held calculator with this method. In addition, the method provides for determination of cascading ratios. The concept of cascading is illustrated in the figure and the definition of the cascading ratio is defined in the figure caption. An important aspect of the method is its approach to the issue of compatibility among segments, in combination with introduction of the concept of compatibility within a segment. Prior approaches involved the use of only averaged material properties. Two materials in direct contact could be examined for compatibility with each other, but there was no general framework for analysis of compatibility. The present method establishes such a framework. The mathematical derivation of the method begins with the definition of reduced efficiency of a thermoelectric generator as the ratio between (1) its thermal-to-electric power-conversion efficiency and (2) its Carnot efficiency (the maximum efficiency theoretically attainable, given its hot- and cold-side temperatures). The derivation involves calculation of the reduced efficiency of a model thermoelectric generator for which the hot-side temperature is only infinitesimally greater than the cold-side temperature. The derivation includes consideration of the ratio (u) between the

  12. Military electronic equipment shelter electrical wiring design of electromagnetic compatibility

    International Nuclear Information System (INIS)

    Yang Xuemei

    2012-01-01

    Electromagnetic compatibility is the military electronics shelter design is an important indicator of the shelter's electrical wiring is the key to the design of electromagnetic compatibility. Introduces the basic concepts of electromagnetic compatibility, and focusing on the shelter layout design problems that need attention, and to solve these problems. (authors)

  13. Improvement of retinal blood vessel detection using morphological component analysis.

    Science.gov (United States)

    Imani, Elaheh; Javidi, Malihe; Pourreza, Hamid-Reza

    2015-03-01

    Detection and quantitative measurement of variations in the retinal blood vessels can help diagnose several diseases including diabetic retinopathy. Intrinsic characteristics of abnormal retinal images make blood vessel detection difficult. The major problem with traditional vessel segmentation algorithms is producing false positive vessels in the presence of diabetic retinopathy lesions. To overcome this problem, a novel scheme for extracting retinal blood vessels based on morphological component analysis (MCA) algorithm is presented in this paper. MCA was developed based on sparse representation of signals. This algorithm assumes that each signal is a linear combination of several morphologically distinct components. In the proposed method, the MCA algorithm with appropriate transforms is adopted to separate vessels and lesions from each other. Afterwards, the Morlet Wavelet Transform is applied to enhance the retinal vessels. The final vessel map is obtained by adaptive thresholding. The performance of the proposed method is measured on the publicly available DRIVE and STARE datasets and compared with several state-of-the-art methods. An accuracy of 0.9523 and 0.9590 has been respectively achieved on the DRIVE and STARE datasets, which are not only greater than most methods, but are also superior to the second human observer's performance. The results show that the proposed method can achieve improved detection in abnormal retinal images and decrease false positive vessels in pathological regions compared to other methods. Also, the robustness of the method in the presence of noise is shown via experimental result. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. 30 CFR 57.6400 - Compatibility of electric detonators.

    Science.gov (United States)

    2010-07-01

    ... Electric Blasting-Surface and Underground § 57.6400 Compatibility of electric detonators. All electric detonators to be fired in a round shall be from the same manufacturer and shall have similar electrical... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compatibility of electric detonators. 57.6400...

  15. 30 CFR 56.6400 - Compatibility of electric detonators.

    Science.gov (United States)

    2010-07-01

    ... Electric Blasting § 56.6400 Compatibility of electric detonators. All electric detonators to be fired in a round shall be from the same manufacturer and shall have similar electrical firing characteristics. ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compatibility of electric detonators. 56.6400...

  16. Fusion-reactor blanket and coolant material compatibility

    International Nuclear Information System (INIS)

    Jeppson, D.W.; Keough, R.F.

    1981-01-01

    Fusion reactor blanket and coolant compatibility tests are being conducted to aid in the selection and design of safe blanket and coolant systems for future fusion reactors. Results of scoping compatibility tests to date are reported for blanket material and water interactions at near operating temperatures. These tests indicate the quantitative hydrogen release, the maximum temperature and pressures produced and the rates of interactions for selected blanket materials

  17. Improved removal of blood contamination from ThinPrep cervical cytology samples for Raman spectroscopic analysis.

    Science.gov (United States)

    Traynor, Damien; Duraipandian, Shiyamala; Martin, Cara M; O'Leary, John J; Lyng, Fiona M

    2018-05-01

    There is an unmet need for methods to help in the early detection of cervical precancer. Optical spectroscopy-based techniques, such as Raman spectroscopy, have shown great potential for diagnosis of different cancers, including cervical cancer. However, relatively few studies have been carried out on liquid-based cytology (LBC) pap test specimens and confounding factors, such as blood contamination, have been identified. Previous work reported a method to remove blood contamination before Raman spectroscopy by pretreatment of the slides with hydrogen peroxide. The aim of the present study was to extend this work to excessively bloody samples to see if these could be rendered suitable for Raman spectroscopy. LBC ThinPrep specimens were treated by adding hydrogen peroxide directly to the vial before slide preparation. Good quality Raman spectra were recorded from negative and high grade (HG) cytology samples with no blood contamination and with heavy blood contamination. Good classification between negative and HG cytology could be achieved for samples with no blood contamination (sensitivity 92%, specificity 93%) and heavy blood contamination (sensitivity 89%, specificity 88%) with poorer classification when samples were combined (sensitivity 82%, specificity 87%). This study demonstrates for the first time the improved potential of Raman spectroscopy for analysis of ThinPrep specimens regardless of blood contamination. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  18. The work compatibility improvement framework: preliminary findings of a case study for defining and measuring the human-at-work system.

    Science.gov (United States)

    Genaidy, A; Karwowski, W; A-Rehim, A

    2007-11-01

    Although researchers traditionally examined the 'risk' characteristics of work settings in health studies, few work models, such as the 'demand-control' and 'motivation-hygiene theory', advocated the study of the positive and the negative aspects of work for the ultimate improvement of work performance. The objectives of the current study were: (a) to examine the positive and negative characteristics of work in the machining department in a small manufacturing plant in the Midwest USA, and, (b) to report the prevalence of musculoskeletal and stress outcomes. A focus group consisting of worker experts from the different job categories in the machining department confirmed the management's concerns. Accordingly, 56 male and female workers, employed in three shifts, were surveyed on the demand/energizer profiles of work characteristics and self-reported musculoskeletal/stress symptoms. On average, one-fourth to one-third of the workers reported 'high' demand, and over 50% of the workers documented 'low' energizers for certain work domains/sub-domains, such as 'physical task content'/'organizational' work domains and 'upper body postural loading'/'time organization' work sub-domains. The prevalence of workers who reported 'high' musculoskeletal/stress disorder cases, was in the range of 25-35% and was consistent with the results of 'high' demands and 'low' energizers. The results of this case study confirm the importance of adopting a comprehensive view for work improvement and sustainable growth opportunities. It is paramount to consider the negative and positive aspects of work characteristics to ensure optimum organizational performance. The Work Compatibility Improvement Framework, proposed in the reported research, is an important endeavor toward the ultimate improvement and sustainable growth of human and organizational performance.

  19. Immune Desensitization Allows Pediatric Blood Group Incompatible Kidney Transplantation.

    Science.gov (United States)

    Stojanovic, Jelena; Adamusiak, Anna; Kessaris, Nicos; Chandak, Pankaj; Ahmed, Zubir; Sebire, Neil J; Walsh, Grainne; Jones, Helen E; Marks, Stephen D; Mamode, Nizam

    2017-06-01

    Blood group incompatible transplantation (ABOi) in children is rare as pretransplant conditioning remains challenging and concerns persist about the potential increased risk of rejection. We describe the results of 11 ABOi pediatric renal transplant recipients in the 2 largest centers in the United Kingdom, sharing the same tailored desensitization protocol. Patients with pretransplant titers of 1 or more in 8 received rituximab 1 month before transplant; tacrolimus and mycophenolate mofetil were started 1 week before surgery. Antibody removal was performed to reduce titers to 1 or less in 8 on the day of the operation. No routine postoperative antibody removal was performed. Death-censored graft survival at last follow-up was 100% in the ABOi and 98% in 50 compatible pediatric transplants. One patient developed grade 2A rejection successfully treated with antithymocyte globulin. Another patient had a titer rise of 2 dilutions treated with 1 immunoadsorption session. There was no histological evidence of rejection in the other 9 patients. One patient developed cytomegalovirus and BK and 2 others EBV and BK viremia. Tailored desensitization in pediatric blood group incompatible kidney transplantation results in excellent outcomes with graft survival and rejection rates comparable with compatible transplants.

  20. The Soluble Epoxide Hydrolase Inhibitor AR9281 Decreases Blood Pressure, Ameliorates Renal Injury and Improves Vascular Function in Hypertension

    Directory of Open Access Journals (Sweden)

    Sean Shaw

    2009-12-01

    Full Text Available Soluble epoxide hydrolase inhibitors (sEHIs are demonstrating promise as potential pharmaceutical agents for the treatment of cardiovascular disease, diabetes, inflammation, and kidney disease. The present study determined the ability of a first-inclass sEHI, AR9281, to decrease blood pressure, improve vascular function, and decrease renal inflammation and injury in angiotensin hypertension. Rats were infused with angiotensin and AR9281 was given orally during the 14-day infusion period. Systolic blood pressure averaged 180 ± 5 mmHg in vehicle treated and AR9281 treatment significantly lowered blood pressure to 142 ± 7 mmHg in angiotensin hypertension. Histological analysis demonstrated decreased injury to the juxtamedullary glomeruli. Renal expression of inflammatory genes was increased in angiotensin hypertension and two weeks of AR9281 treatment decreased this index of renal inflammation. Vascular function in angiotensin hypertension was also improved by AR9281 treatment. Decreased afferent arteriolar and mesenteric resistance endothelial dependent dilator responses were ameliorated by AR9281 treatment of angiotensin hypertensive rats. These data demonstrate that the first-in-class sEHI, AR9281, lowers blood pressure, improves vascular function and reduces renal damage in angiotensin hypertension.

  1. Developing 2 C-compatible investment criteria

    Energy Technology Data Exchange (ETDEWEB)

    Roeser, Frauke [NewClimate - Institute for Climate Policy and Global Sustainability gGmbH, Bonn (Germany); Weischer, Lutz [Germanwatch e.V., Koeln (Germany); Thomae, Jakob [2degrees Investing Initiative, New York, NY (United States); Hoehne, Niklas; Hagemann, Markus; El Alaoui, Alexander; Bals, Christoph; Eckstein, David; Kreft, Soenke; Rosse, Morten

    2015-11-30

    This report studies the development of criteria for assessing the compatibility of financial investments with the international goal to limit global temperature increase to below 2 C above pre-industrial levels. The findings are intended as a starting point and a key input for a longer term process to develop consensus-based 2 C investing criteria. The focus here is placed on investments in projects and physical assets, in particular of development and climate finance organisations. In order to limit global temperature increase to 2 C, global greenhouse gas (GHG) emissions will have to be reduced significantly, eventually to zero, during the course of this century. This requires shifting capital from high to low carbon investments as well as significant capital mobilisation for investments in 2 C-compatible infrastructure. Given the long lifetime of physical assets, and the urgency of decarbonisation over the coming decades, this needs to begin today. Public financial institutions can play a prominent role in contributing to aligning investment flows with the 2 C limit, as well as in closing the current infrastructure investment gap, responding to their explicit or implicit climate mandates and leadership role in the finance sector. The majority of international financial institutions integrate climate considerations into their finance decisions to some degree, and are familiar with different types of criteria, including positive and negative lists, qualitative and quantitative benchmarks, and the use of shadow carbon pricing. However, current approaches do not link to the 2 C limit. 2 C investment criteria are therefore needed to guide investors in this regard. Such criteria may also support other purposes, including an understanding of climate risks and improved reporting and accountability.

  2. Developing 2 C-compatible investment criteria

    International Nuclear Information System (INIS)

    Roeser, Frauke; Weischer, Lutz; Thomae, Jakob; Hoehne, Niklas; Hagemann, Markus; El Alaoui, Alexander; Bals, Christoph; Eckstein, David; Kreft, Soenke; Rosse, Morten

    2015-01-01

    This report studies the development of criteria for assessing the compatibility of financial investments with the international goal to limit global temperature increase to below 2 C above pre-industrial levels. The findings are intended as a starting point and a key input for a longer term process to develop consensus-based 2 C investing criteria. The focus here is placed on investments in projects and physical assets, in particular of development and climate finance organisations. In order to limit global temperature increase to 2 C, global greenhouse gas (GHG) emissions will have to be reduced significantly, eventually to zero, during the course of this century. This requires shifting capital from high to low carbon investments as well as significant capital mobilisation for investments in 2 C-compatible infrastructure. Given the long lifetime of physical assets, and the urgency of decarbonisation over the coming decades, this needs to begin today. Public financial institutions can play a prominent role in contributing to aligning investment flows with the 2 C limit, as well as in closing the current infrastructure investment gap, responding to their explicit or implicit climate mandates and leadership role in the finance sector. The majority of international financial institutions integrate climate considerations into their finance decisions to some degree, and are familiar with different types of criteria, including positive and negative lists, qualitative and quantitative benchmarks, and the use of shadow carbon pricing. However, current approaches do not link to the 2 C limit. 2 C investment criteria are therefore needed to guide investors in this regard. Such criteria may also support other purposes, including an understanding of climate risks and improved reporting and accountability.

  3. An MR-compatible neonatal incubator.

    Science.gov (United States)

    Paley, M N J; Hart, A R; Lait, M; Griffiths, P D

    2012-07-01

    To develop a neonatal MR-compatible incubator for transporting babies between a neonatal intensive care unit and an MRI unit that is within the same hospital but geographically separate. The system was strapped to a standard MR-compatible patient trolley, which provides space for resuscitation outside the incubator. A constant-temperature exothermic heat pad was used to maintain temperature together with a logging fluoro-optic temperature monitor and alarm system. The system has been designed to accommodate standard knee-sized coils from the major MR manufacturers. The original incubator was constructed from carbon fibre, but this required modification to prevent radiofrequency shading artefacts due to the conducting properties of the carbon fibre. A high-tensile polyester material was used, which combined light weight with high impact strength. The system could be moved onto the patient bed with the coils and infant in place by one technologist. Studies in eight neonatal patients produced high quality 1.5 T MR images with low motion artefacts. The incubator should also be compatible with imaging in 3 T MR systems, although further work is required to establish this. Images were acquired using both rapid and high-resolution sequences, including three-dimensional volumes, proton spectra and diffusion weighting. The incubator provides a safe, quiet environment for neonates during transport and imaging, at low cost.

  4. Virtual arterial blood pressure feedback improves chest compression quality during simulated resuscitation.

    Science.gov (United States)

    Rieke, Horst; Rieke, Martin; Gado, Samkon K; Nietert, Paul J; Field, Larry C; Clark, Carlee A; Furse, Cory M; McEvoy, Matthew D

    2013-11-01

    Quality chest compressions (CC) are the most important factor in successful cardiopulmonary resuscitation. Adjustment of CC based upon an invasive arterial blood pressure (ABP) display would be theoretically beneficial. Additionally, having one compressor present for longer than a 2-min cycle with an ABP display may allow for a learning process to further maximize CC. Accordingly, we tested the hypothesis that CC can be improved with a real-time display of invasively measured blood pressure and with an unchanged, physically fit compressor. A manikin was attached to an ABP display derived from a hemodynamic model responding to parameters of CC rate, depth, and compression-decompression ratio. The area under the blood pressure curve over time (AUC) was used for data analysis. Each participant (N=20) performed 4 CPR sessions: (1) No ABP display, exchange of compressor every 2 min; (2) ABP display, exchange of compressor every 2 min; (3) no ABP display, no exchange of the compressor; (4) ABP display, no exchange of the compressor. Data were analyzed by ANOVA. Significance was set at a p-valueAUC for cycles without ABP display was 5201 mm Hgs (95% confidence interval (CI) of 4804-5597 mm Hgs), and for cycles with ABP display 6110 mm Hgs (95% CI of 5715-6507 mm Hgs) (pAUC increase with ABP display for each participant was 20.2±17.4% 95 CI (p<0.0001). Our study confirms the hypothesis that a real-time display of simulated ABP during CPR that responds to participant performance improves achieved and sustained ABP. However, without any real-time visual feedback, even fit compressors demonstrated degradation of CC quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Blood donation by African migrants and refugees in Australia: the role of demographic and socio-economic factors.

    Science.gov (United States)

    McQuilten, Z; Waters, N; Polonsky, M; Renzaho, A

    2014-02-01

    To establish blood donation rates among African refugees and migrants and identify demographic and socio-economic factors that are associated with their blood donation. A cross-sectional survey of 425 migrants and refugees living in Victoria and South Australia was used to assess blood donation status. The association between blood donation and demographic and socio-economic factors was assessed using multiple logistic regression analysis. Overall, 73 participants (17·2%; 95% CI: 13·6-20·8) reported having donated blood previously. Of the total sample, 2·4% (95% CI: 0·9-3·8) reported having given blood in Australia; 12·9% (95% CI: 9·7-16·1) had given blood prior to migration to Australia (i.e. country of birth or transition); and 1·9% (95% CI: 0·6-3·2) indicated they had given blood in an unspecified country. In the univariate model, age, country of birth, blood donation knowledge, religion, educational attainment, migration and employment status were all associated with blood donation status. However, in the multivariate model, only age >45 years (odds ratio [OR] 5·72; 95% CI 2·11-15·46), African region of origin (OR 15·89; 95% CI 3·89-65) and blood donation knowledge (OR 4·46; 95% CI 1·57-12·7) were associated with blood donation. In order to increase the number of blood donors among African migrants, promoting knowledge and awareness of issues associated with blood donation in Australia should be emphasized. Consideration should be given to identifying these potential migrant donors to improve the availability of compatible blood for patients of African descent. © 2013 International Society of Blood Transfusion.

  6. Fusion-reactor blanket-material safety-compatibility studies

    International Nuclear Information System (INIS)

    Jeppson, D.W.; Muhlestein, L.D.; Keough, R.F.; Cohen, S.

    1982-11-01

    Blanket material selection for fusion reactors is strongly influenced by the desire to minimize safety and environmental concerns. Blanket material safety compatibility studies are being conducted to identify and characterize blanket-coolant-material interactions under postulated reactor accident conditions. Recently completed scoping compatibility tests indicate that : (1) ternary oxides (LiAlO 2 , Li 2 ZrO 3 , Li 2 SiO 3 , Li 4 SiO 4 and LiTiO 3 ) at postulated blanket operating temperatures are compatible with water coolant, while liquid lithium and Li 7 Pb 2 alloy reactions with water generate heat, aerosol and hydrogen; (2) lithium oxide and Li 17 Pb 83 alloy react mildly with water requiring special precautions to control hydrogen release; (3) liquid lithium reacts substantially, while Li 17 Pb 83 alloy reacts mildly with concrete to produce hydrogen; and (4) liquid lithium-air reactions present some major safety concerns

  7. Blood interaction with a Bioline heparin coated HIA-VAD : A study on calves

    NARCIS (Netherlands)

    vanderKamp, KWHJ; Magielse, CPE; Elstrodt, JM; vanderMeer, J; vanOeveren, W; Rakhorst, G

    The blood compatibility of ventricular assist devices developed by the Helmholtz institute Aachen (HA-VAD's) was tested on calves. Seven calves received a non-coated HIA-VAD (control) and three a Bioline heparin coated device. The circulatory support of these HIA-VAD's lasted one week. Mechanical

  8. A randomized trial using motivational interviewing for maintenance of blood pressure improvements in a community-engaged lifestyle intervention: HUB city steps

    Science.gov (United States)

    Landry, Alicia; Madson, Michael; Thomson, Jessica; Zoellner, Jamie; Connell, Carol; Yadrick, Kathleen

    2015-01-01

    Little is known about the effective dose of motivational interviewing for maintaining intervention-induced health outcome improvements. The purpose of this study was to compare effects of two doses of motivational interviewing for maintaining blood pressure improvements in a community-engaged lifestyle intervention conducted with African-Americans. Participants were tracked through a 12-month maintenance phase following a 6-month intervention targeting physical activity and diet. For the maintenance phase, participants were randomized to receive a low (4) or high (10) dose of motivational interviewing delivered via telephone by trained research staff. Generalized linear models were used to test for group differences in blood pressure. Blood pressure significantly increased during the maintenance phase. No differences were apparent between randomized groups. Results suggest that 10 or fewer motivational interviewing calls over a 12-month period may be insufficient to maintain post-intervention improvements in blood pressure. Further research is needed to determine optimal strategies for maintaining changes. PMID:26590242

  9. Utilizing Radiofrequency Identification Technology to Improve Safety and Management of Blood Bank Supply Chains.

    Science.gov (United States)

    Coustasse, Alberto; Meadows, Pamela; Hall, Robert S; Hibner, Travis; Deslich, Stacie

    2015-11-01

    The importance of efficiency in the supply chain of perishable products, such as the blood products used in transfusion services, cannot be overstated. Many problems can occur, such as the outdating of products, inventory management issues, patient misidentification, and mistransfusion. The purpose of this article was to identify the benefits and barriers associated with radiofrequency identification (RFID) usage in improving the blood bank supply chain. The methodology for this study was a qualitative literature review following a systematic approach. The review was limited to sources published from 2000 to 2014 in the English language. Sixty-five sources were found, and 56 were used in this research study. According to the finding of the present study, there are numerous benefits and barriers to RFID utilization in blood bank supply chains. RFID technology offers several benefits with regard to blood bank product management, including decreased transfusion errors, reduction of product loss, and more efficient inventory management. Barriers to RFID implementation include the cost associated with system implementation and patient privacy issues. Implementation of an RFID system can be a significant investment. However, when observing the positive impact that such systems may have on transfusion safety and inventory management, the cost associated with RFID systems can easily be justified. RFID in blood bank inventory management is vital to ensuring efficient product inventory management and positive patient outcomes.

  10. 47 CFR 76.630 - Compatibility with consumer electronics equipment.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Compatibility with consumer electronics equipment. 76.630 Section 76.630 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... Compatibility with consumer electronics equipment. (a) Cable system operators shall not scramble or otherwise...

  11. Scotblood 2015: Improving and delivering blood products, novel cellular therapies, and celebrating patients and donor engagement within transfusion services.

    Science.gov (United States)

    Colligan, David; McGowan, Neil; Seghatchian, Jerard

    2016-08-01

    Blood Transfusion Services are striving to continually improve the efficacy and quality of their blood products whilst also simultaneously diversifying into novel cellular products. For this to be successful the relationships between the various arms of the organisation must be strong and interlinked. As new technologies impact on the products that blood transfusion services supply it should be noted that the interaction between the service and its donor base is also affected by advancing technologies. Social media has fundamentally altered the way in which the public can access information and news, as such blood services must engage and interact appropriately with these new forms of media. As a reflection of these challenges the Scotblood 2015 programme was focussed on service and product improvement, donor engagement and people centred transfusion. This commentary comprises summaries of the presentations, based in part on the abstracts provided by the speakers. Copyright © 2016. Published by Elsevier Ltd.

  12. Topiramate improves neurovascular function, epidermal nerve fiber morphology, and metabolism in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Boyd A

    2010-12-01

    Full Text Available Amanda L Boyd, Patricia M Barlow, Gary L Pittenger, Kathryn F Simmons, Aaron I VinikDepartment of Internal Medicine, Eastern Virginia Medical School, Norfolk, VA, USAPurpose: To assess the effects of topiramate on C-fiber function, nerve fiber morphology, and metabolism (including insulin sensitivity, obesity, and dyslipidemia in type 2 diabetes.Patients and methods: We conducted an 18-week, open-label trial treating patients with topiramate. Twenty subjects with type 2 diabetes and neuropathy (61.5 ± 1.29 years; 15 male, 5 female were enrolled and completed the trial. Neuropathy was evaluated by total neuropathy scores, nerve conduction studies, quantitative sensory tests, laser Doppler skin blood flow, and intraepidermal nerve fibers in skin biopsies.Results: Topiramate treatment improved symptoms compatible with C-fiber dysfunction. Weight, blood pressure, and hemoglobin A1c also improved. Laser Doppler skin blood flow improved significantly after 12 weeks of treatment, but returned to baseline at 18 weeks. After 18 weeks of treatment there was a significant increase in intraepidermal nerve fiber length at the forearm, thigh, and proximal leg. Intraepidermal nerve fiber density was significantly increased by topiramate in the proximal leg.Conclusion: This study is the first to demonstrate that it is possible to induce skin intraepidermal nerve fiber regeneration accompanied by enhancement of neurovascular function, translating into improved symptoms as well as sensory nerve function. The simultaneous improvement of selective metabolic indices may play a role in this effect, but this remains to be determined.Keywords: diabetic neuropathy, skin blood flow, skin biopsy, diabetes

  13. The remote handling compatibility analysis of the ITER generic upper port plug structure

    Energy Technology Data Exchange (ETDEWEB)

    Ronden, D.M.S., E-mail: d.m.s.ronden@differ.nl [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Dammann, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Elzendoorn, B. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Giacomin, T. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Heemskerk, C. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Loesser, D. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Maquet, P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Oosterhout, J. van [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Pak, S.; Pitcher, C.S.; Portales, M.; Proust, M.; Udintsev, V.S.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France)

    2014-10-15

    Highlights: • We describe the remote handling compatibility of the ITER generic upper port plug. • Concepts are presented of specific design solutions to improve RH compatibility. • Simulation in VR of the GUPP DSM replacement indicates possible collisions. • Specific tooling concepts are proposed for GUPP handling equipment for the hot cell. - Abstract: The ITER diagnostics generic upper port plug (GUPP) is developed as a standardized design for all diagnostic upper port plugs, in which a variety of payloads can be mounted. Here, the remote handling compatibility analysis (RHCA) of the GUPP design is presented that was performed for the GUPP final design review. The analysis focuses mainly on the insertion and extraction procedure of the diagnostic shield module (DSM), a removable cassette that contains the diagnostic in-vessel components. It is foreseen that the DSM is a replaceable component – the procedure of which is to be performed inside the ITER hot cell facility (HCF), where the GUPP can be oriented in a vertical position. The DSM removal procedure in the HCF consists of removing locking pins, an M30 sized shoulder bolt and two electrical straps through the use of a dexterous manipulator, after which the DSM is lifted out of the GUPP by an overhead crane. For optimum access to its internals, the DSM is mounted in a handling device. The insertion of a new or refurbished DSM follows the reverse procedure. The RHCA shows that the GUPP design requires a moderate amount of changes to become fully compatible with RH maintenance requirements.

  14. The remote handling compatibility analysis of the ITER generic upper port plug structure

    International Nuclear Information System (INIS)

    Ronden, D.M.S.; Dammann, A.; Elzendoorn, B.; Giacomin, T.; Heemskerk, C.; Loesser, D.; Maquet, P.; Oosterhout, J. van; Pak, S.; Pitcher, C.S.; Portales, M.; Proust, M.; Udintsev, V.S.; Walsh, M.J.

    2014-01-01

    Highlights: • We describe the remote handling compatibility of the ITER generic upper port plug. • Concepts are presented of specific design solutions to improve RH compatibility. • Simulation in VR of the GUPP DSM replacement indicates possible collisions. • Specific tooling concepts are proposed for GUPP handling equipment for the hot cell. - Abstract: The ITER diagnostics generic upper port plug (GUPP) is developed as a standardized design for all diagnostic upper port plugs, in which a variety of payloads can be mounted. Here, the remote handling compatibility analysis (RHCA) of the GUPP design is presented that was performed for the GUPP final design review. The analysis focuses mainly on the insertion and extraction procedure of the diagnostic shield module (DSM), a removable cassette that contains the diagnostic in-vessel components. It is foreseen that the DSM is a replaceable component – the procedure of which is to be performed inside the ITER hot cell facility (HCF), where the GUPP can be oriented in a vertical position. The DSM removal procedure in the HCF consists of removing locking pins, an M30 sized shoulder bolt and two electrical straps through the use of a dexterous manipulator, after which the DSM is lifted out of the GUPP by an overhead crane. For optimum access to its internals, the DSM is mounted in a handling device. The insertion of a new or refurbished DSM follows the reverse procedure. The RHCA shows that the GUPP design requires a moderate amount of changes to become fully compatible with RH maintenance requirements

  15. Blueberries improve endothelial function, but not blood pressure, in adults with metabolic syndrome: a randomized, double-blind, placebo-controlled clinical trial.

    Science.gov (United States)

    Stull, April J; Cash, Katherine C; Champagne, Catherine M; Gupta, Alok K; Boston, Raymond; Beyl, Robbie A; Johnson, William D; Cefalu, William T

    2015-05-27

    Blueberry consumption has been shown to have various health benefits in humans. However, little is known about the effect of blueberry consumption on blood pressure, endothelial function and insulin sensitivity in humans. The present study investigated the role of blueberry consumption on modifying blood pressure in subjects with metabolic syndrome. In addition, endothelial function and insulin sensitivity (secondary measurements) were also assessed. A double-blind and placebo-controlled study was conducted in 44 adults (blueberry, n = 23; and placebo, n = 21). They were randomized to receive a blueberry or placebo smoothie twice daily for six weeks. Twenty-four-hour ambulatory blood pressure, endothelial function and insulin sensitivity were assessed pre- and post-intervention. The blood pressure and insulin sensitivity did not differ between the blueberry and placebo groups. However, the mean change in resting endothelial function, expressed as reactive hyperemia index (RHI), was improved significantly more in the group consuming the blueberries versus the placebo group (p = 0.024). Even after adjusting for confounding factors, i.e., the percent body fat and gender, the blueberry group still had a greater improvement in endothelial function when compared to their counterpart (RHI; 0.32 ± 0.13 versus -0.33 ± 0.14; p = 0.0023). In conclusion, daily dietary consumption of blueberries did not improve blood pressure, but improved (i.e., increased) endothelial function over six weeks in subjects with metabolic syndrome.

  16. DUPIC fuel compatibility assessment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hang Bok; Rho, G. H.; Park, J. W. [and others

    2000-03-01

    The purpose of this study is to assess the compatibility of DUPIC(Direct Use of Spent PWR Fuel in CANDU Reactors) fuel with the current CANDU 6 reactor, which is one of the technology being developed to utilize the spent PWR fuel in CANDU reactors. The phase 1 study of this project includes the feasibility analysis on applicability of the current core design method, the feasibility analysis on operation of the DUPIC fuel core, the compatibility analysis on individual reactor system, the sensitivity analysis on the fuel composition, and the economic analysis on DUPIC fuel cycle. The results of the validation calculations have confirmed that the current core analysis system is acceptable for the feasibility study of the DUPIC fuel compatibility analysis. The results of core simulations have shown that both natural uranium and DUPIC fuel cores are almost the same from the viewpoint of the operational performance. For individual reactor system including reactively devices, the functional requirements of each system are satisfied in general. However, because of the pronounced power flattening in the DUPIC core, the radiation damage on the critical components increases, which should be investigated more in the future. The DUPIC fuel composition heterogeneity dose not to impose any serious effect on the reactor operation if the fuel composition is adjusted. The economics analysis has been performed through conceptual design studies on the DUPIC fuel fabrication, fuel handling in a plant, and spent fuel disposal, which has shown that the DUPIC fuel cycle is comparable to the once-trough fuel cycle considering uncertainties associated with unit costs of the fuel cycle components. The results of Phase 1 study have shown that it is feasible to use the DUPIC fuel in CANDU reactors without major changes in hardware. However further studies are required to confirm the safety of the reactor under accident condition.

  17. DUPIC fuel compatibility assessment

    International Nuclear Information System (INIS)

    Choi, Hang Bok; Rho, G. H.; Park, J. W. and others

    2000-03-01

    The purpose of this study is to assess the compatibility of DUPIC(Direct Use of Spent PWR Fuel in CANDU Reactors) fuel with the current CANDU 6 reactor, which is one of the technology being developed to utilize the spent PWR fuel in CANDU reactors. The phase 1 study of this project includes the feasibility analysis on applicability of the current core design method, the feasibility analysis on operation of the DUPIC fuel core, the compatibility analysis on individual reactor system, the sensitivity analysis on the fuel composition, and the economic analysis on DUPIC fuel cycle. The results of the validation calculations have confirmed that the current core analysis system is acceptable for the feasibility study of the DUPIC fuel compatibility analysis. The results of core simulations have shown that both natural uranium and DUPIC fuel cores are almost the same from the viewpoint of the operational performance. For individual reactor system including reactively devices, the functional requirements of each system are satisfied in general. However, because of the pronounced power flattening in the DUPIC core, the radiation damage on the critical components increases, which should be investigated more in the future. The DUPIC fuel composition heterogeneity dose not to impose any serious effect on the reactor operation if the fuel composition is adjusted. The economics analysis has been performed through conceptual design studies on the DUPIC fuel fabrication, fuel handling in a plant, and spent fuel disposal, which has shown that the DUPIC fuel cycle is comparable to the once-trough fuel cycle considering uncertainties associated with unit costs of the fuel cycle components. The results of Phase 1 study have shown that it is feasible to use the DUPIC fuel in CANDU reactors without major changes in hardware. However further studies are required to confirm the safety of the reactor under accident condition

  18. [Compatibility of family and medical profession].

    Science.gov (United States)

    Bundy, B D; Bellemann, N; Weber, M-A

    2011-09-01

    The compatibility of family and profession is especially difficult for employees in medical professions because of shift work and overtime. It seems that in the future women are going to represent the majority of medical professionals. Hence, with the manifest lack of physicians social aspects will also play a bigger role in the choice of the place of employment. In most families the classic role model prevails although women are well educated and men also set a high value on the compatibility of family and profession and would like to take parental leave and work in flexible working hours. This represents a chance, especially for radiology.

  19. Compatibility of anhydride cured epoxies with hexanitroazobenzene (HNAB) and hexanitrostilbene (HNS)

    International Nuclear Information System (INIS)

    Massis, T.M.; Wischmann, K.B.

    1985-01-01

    The explosives HNAB (hexanitroazobenzene) and HNS (hexanitrostilbene) have compatibility problems with amine-cured epoxy systems. A program was instituted to find compatible polymeric substitutes for use with these explosives. These polymeric materials must have rigid structures after curing for both adhesive and encapsulant applications. A promising class of epoxy materials using anhydride curing agents with various catalysts to trigger the cure reaction were developed. These polymeric systems have very good compatibility with HNS. Of those tested with HNAB, the anhydride epoxy system that used uranyl nitrate as the catalyst was found to be marginally compatible while the others were incompatible. These results indicated further studies are needed. The CRT (chemical reactivity test) was used to evaluate the compatibility of these materials. 6 references, 2 figures, 5 tables

  20. Improvement of Diurnal Blood Pressure Variation by Azilsartan.

    Science.gov (United States)

    Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori

    2018-01-01

    Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers.

  1. Oxygen Compatibility of Brass-Filled PTFE Compared to Commonly Used Fluorinated Polymers for Oxygen Systems

    Science.gov (United States)

    Herald, Stephen D.; Frisby, Paul M.; Davis, Samuel Eddie

    2009-01-01

    Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to

  2. In vivo study of rat cortical hemodynamics using a stereotaxic-apparatus-compatible photoacoustic microscope.

    Science.gov (United States)

    Guo, Heng; Chen, Qian; Qi, Weizhi; Chen, Xingxing; Xi, Lei

    2018-04-19

    Brain imaging is an important technique in cognitive neuroscience. In this article, we designed a stereotaxic-apparatus-compatible photoacoustic microscope for the studies of rat cortical hemodynamics. Compared with existing optical resolution photoacoustic microscopy (ORPAM) systems, the probe owns feature of fast, light and miniature. In this microscope, we integrated a miniaturized ultrasound transducer with a center frequency of 10 MHz to detect photoacoustic signals and a 2-dimensional (2D) microelectromechanical system (MEMS) scanner to achieve raster scanning of the optical focus. Based on phantom evaluation, this imaging probe has a high lateral resolution of 3.8 μm and an effective imaging domain of 2 × 2 mm 2 . Different from conventional ORPAMs, combining with standard stereotaxic apparatus enables broad studies of rodent brains without any motion artifact. To show its capability, we successfully captured red blood cell flow in the capillary, monitored the vascular changes during bleeding and blood infusion and visualized cortical hemodynamics induced by middle cerebral artery occlusion. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Immunological Compatibility of Bone Tissues from Alpha-1,3-galactosyltransferase Knockout Pig for Xenotransplantation

    Directory of Open Access Journals (Sweden)

    Se Eun Kim

    2018-01-01

    Full Text Available We investigated whether the lack of galactosyltransferase (α-Gal expression in bone tissue is associated with reduced immune response of human peripheral blood mononuclear cells (PBMCs against pig bone tissue. When human PBMC obtained from heparinized blood of healthy volunteers was stimulated with bone extracts of pigs with α-1,3-galactosyltransferase knock out (α-Gal KO, the proliferation of human PBMCs and production of proinflammatory cytokines such as TNF-α and IL-1β were significantly reduced compared to those stimulated with bone extracts of wild type (WT pigs. In addition, activation of CD4+ helper T cells and production of IL-2, IFN-γ, and IL-17 were reduced upon stimulation with bone tissue extracts from α-Gal KO pigs. This is possibly due to the lowered activities of the NF-κB, p38, ERK, and JNK signaling pathways. Our findings can be used to evaluate the compatibility of bone tissues from α-Gal KO pigs with human bone grafting as novel natural biomaterials, thereby increasing the feasibility of future clinical applications.

  4. Conceptual design of CFETR divertor remote handling compatible structure

    International Nuclear Information System (INIS)

    Dai, Huaichu; Yao, Damao; Cao, Lei; Zhou, Zibo; Li, Lei

    2016-01-01

    Highlights: • Conceptual design for the CFETR divertor have been proposed, especially the divertor remote handling compatible structure. • The degrees of freedom of the divertor are analyzed in order to validate the design the divertor supports structure. • Besides the ITER-like scheme, a new scheme for the divertor remote handling compatible supports is proposed, that is the rack and pinion mechanism. • The installation/removel process is verified through simulation in Delmia in order to check design quality for remote handling requirements. - Abstract: Divertor is one of key components of tokamak fusion reactor. The CFETR is China Fusion Engineering Test Reactor. Its divertor will expose to tritium environment and neutron radiation. Materials of the divertor will be radioactived, and cannot be handled by personnel directly. To develop structure which compatible with robots handle for installation, maintenance and removing is required. This paper introduces a conceptual design of CFETR divertor module which compatible with remote handling end-effectors. The divertor module is confined by inner and outer support. The inner support is only confined divertor module radial, toroidal and vertical moving freedom degrees, but not confined rotating freedom degrees. The outer support is the structure that can confine rotating freedom degrees and should also be compatible with remote handling end-effectors.

  5. Conceptual design of CFETR divertor remote handling compatible structure

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Huaichu, E-mail: yaodm@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei (China); Yao, Damao; Cao, Lei; Zhou, Zibo; Li, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-11-15

    Highlights: • Conceptual design for the CFETR divertor have been proposed, especially the divertor remote handling compatible structure. • The degrees of freedom of the divertor are analyzed in order to validate the design the divertor supports structure. • Besides the ITER-like scheme, a new scheme for the divertor remote handling compatible supports is proposed, that is the rack and pinion mechanism. • The installation/removel process is verified through simulation in Delmia in order to check design quality for remote handling requirements. - Abstract: Divertor is one of key components of tokamak fusion reactor. The CFETR is China Fusion Engineering Test Reactor. Its divertor will expose to tritium environment and neutron radiation. Materials of the divertor will be radioactived, and cannot be handled by personnel directly. To develop structure which compatible with robots handle for installation, maintenance and removing is required. This paper introduces a conceptual design of CFETR divertor module which compatible with remote handling end-effectors. The divertor module is confined by inner and outer support. The inner support is only confined divertor module radial, toroidal and vertical moving freedom degrees, but not confined rotating freedom degrees. The outer support is the structure that can confine rotating freedom degrees and should also be compatible with remote handling end-effectors.

  6. Transfusions of blood and blood products and viral infections

    Directory of Open Access Journals (Sweden)

    Marta Wróblewska

    2002-06-01

    Full Text Available Transfusions of blood and blood products are commonly used in medicine, but being biological materials they carry a risk of transmitting infections--viral, bacterial, parasitic, as well as prions. Laboratory tests used for screening of donated blood for viral infections at present cannot detect all infectious units. Criteria for selection of blood donors therefore must be very strict, while methods of inactivation of viruses and laboratory assays for detection of their presence must be improved. Indications for blood transfusion should be restricted.

  7. Obtention of graft copolymers by ionizing radiation, characterization and study of hemo-compatible properties

    International Nuclear Information System (INIS)

    Queiroz, A.A.A. de.

    1993-01-01

    The present work had as objectives the obtention and characterization of grafting copolymers by radiation induced polymerization and the study of its hemo compatible properties. The relationship between grafting conditions and anti-trombogenicity was examined for the purpose of clearing the necessity of controlling grafting conditions to enhance the copolymers blood compatibility. Two methods were chosen to accomplish the irradiation: mutual and pre-irradiation (peroxidation) of the films in 6O Co source and electron beam accelerator. Primarily grafting parameters were studied in the systems of the monomers N, N-dimethyl acrylamide (DMAA) and acrylic acid (AA) with the polymeric films: poly (tetrafluoroethylene) (PTFE), poly (ethylene-co-tetrafluoroethylene) (PETFE), low density polyethylene (LDPE) and poly (vinyl chloride) (PVC). The simultaneous irradiation was effective in the polymerization of all the substrates above mentioned, although the peroxidation method has given better results for PETFE-DMAA, LDPE-g-DMAA, LDPE-g-AA and PVC-g-AA. In the system AA/LDPE and AA/PVC the homo polymerization was controlled by the addition of the comonomer N, N-dimethyl acrylic acid (DMA). As for the grafting parameters, low dose rate and low irradiation dose, showed to be very effective for the graftability of DMAA and AA on the substrates. (author). 129 refs, 51 figs, 7 tabs

  8. An implantable centrifugal blood pump for long term circulatory support.

    Science.gov (United States)

    Yamazaki, K; Litwak, P; Kormos, R L; Mori, T; Tagusari, O; Antaki, J F; Kameneva, M; Watach, M; Gordon, L; Umezu, M; Tomioka, J; Koyanagi, H; Griffith, B P

    1997-01-01

    A compact centrifugal blood pump was developed as an implantable left ventricular assist system. The impeller diameter is 40 mm and the pump dimensions are 55 x 64 mm. This first prototype was fabricated from titanium alloy, resulting in a pump weight of 400 g including a brushless DC motor. Weight of the second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon to improve blood compatibility. Flow rates of over 7 L/min against 100 mmHg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system ("Cool-Seal") is used as a shaft seal. In this seal system, seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. The purge fluid is continuously purified and sterilized by an ultrafiltration filter incorporated into the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular apex-descending aorta bypass was performed utilizing a PTFE (Polytetrafluoroethylene) vascular graft, with the pump placed in the left thoracic cavity. In two in vivo experiments, pump flow rate was maintained at 5-8 L/min, and pump power consumption remained stable at 9-10 W. All plasma free hemoglobin levels were measured at < 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (< 0.5 ml/ day). Both animals remain under observation after 162 and 91 days of continuous pump function.

  9. Influence of non-thermal plasma forming gases on improvement of surface properties of low density polyethylene (LDPE)

    Energy Technology Data Exchange (ETDEWEB)

    Pandiyaraj, K. Navaneetha, E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Ruzybayev, Inci; Shah, S. Ismat [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark, NJ (United States); Su, Pi-Guey [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Halleluyah, Jr. mercy; Halim, Ahmad Sukari [School of Medical Sciences, Health Campus Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan (Malaysia)

    2014-07-01

    Owing to the superior physico-chemical properties, the low density polyethylene (LDPE) has been widely used in the various industrial applications; especially in biomedical field for artificial organs, medical devices and disposable clinical apparatus. However, the poor anticoagulation property is one of the main drawbacks of the LDPE due to its poor surface properties. Therefore, in this paper we present the effect of plasma forming gases such as argon (Ar), oxygen (O{sub 2}), air and argon-oxygen (Ar + O{sub 2}) mixture on improvement of the surfaces properties of LDPE film using direct current (dc) excited glow discharge plasma. Contact angle with evaluation of surface energy, X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM) techniques were used to examine the change in surface properties such as hydrophilicity, chemical composition and surface topography, respectively. Furthermore, the hydrophobic recovery of the plasma treated LDPE was analyzed using ageing effect under different storage condition i.e. in air and water. The adhesive strength of the LDPE films was determined using T-peel test. In vitro tests were used to examine the blood compatibility of the surface modified LDPE films. It has been found that the hydrophilicity of the various plasma treated LDPE films was improved significantly due to the formation of oxygen containing polar groups such as OH, COO, C-O, C=O as confirmed by contact angle and XPS analysis. AFM revealed the changes in surface topography of plasma processed films. The gas mixture Ar + O{sub 2} plasma influenced the remarkable improvement on the surface properties of a LDPE film compared with other gaseous plasmas. These physiochemical changes induced by the plasma on the surface facilitate to improve the adhesive strength and blood compatibility.

  10. Influence of non-thermal plasma forming gases on improvement of surface properties of low density polyethylene (LDPE)

    International Nuclear Information System (INIS)

    Pandiyaraj, K. Navaneetha; Deshmukh, R.R.; Ruzybayev, Inci; Shah, S. Ismat; Su, Pi-Guey; Halleluyah, Jr. mercy; Halim, Ahmad Sukari

    2014-01-01

    Owing to the superior physico-chemical properties, the low density polyethylene (LDPE) has been widely used in the various industrial applications; especially in biomedical field for artificial organs, medical devices and disposable clinical apparatus. However, the poor anticoagulation property is one of the main drawbacks of the LDPE due to its poor surface properties. Therefore, in this paper we present the effect of plasma forming gases such as argon (Ar), oxygen (O 2 ), air and argon-oxygen (Ar + O 2 ) mixture on improvement of the surfaces properties of LDPE film using direct current (dc) excited glow discharge plasma. Contact angle with evaluation of surface energy, X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM) techniques were used to examine the change in surface properties such as hydrophilicity, chemical composition and surface topography, respectively. Furthermore, the hydrophobic recovery of the plasma treated LDPE was analyzed using ageing effect under different storage condition i.e. in air and water. The adhesive strength of the LDPE films was determined using T-peel test. In vitro tests were used to examine the blood compatibility of the surface modified LDPE films. It has been found that the hydrophilicity of the various plasma treated LDPE films was improved significantly due to the formation of oxygen containing polar groups such as OH, COO, C-O, C=O as confirmed by contact angle and XPS analysis. AFM revealed the changes in surface topography of plasma processed films. The gas mixture Ar + O 2 plasma influenced the remarkable improvement on the surface properties of a LDPE film compared with other gaseous plasmas. These physiochemical changes induced by the plasma on the surface facilitate to improve the adhesive strength and blood compatibility.

  11. Analysis and Application of Antagonism Compound Prescription Compatibility

    Science.gov (United States)

    Li, Mengyan; Wang, Can; Bai, Ming; Miao, Mingsan

    2018-01-01

    Deer horn glue is deer family animals deer or red deer horn made of solid plastic animal medicine, according to Chinese medicine “seven emotions together” theory, the antler and other Chinese herbal medicines compatibility can be better play its Medicinal value. In this paper, the chemical composition, pharmacological effects, compatibility analysis, clinical application and classic ancient prescriptions of antler are reviewed in recent years.

  12. 47 CFR 20.19 - Hearing aid-compatible mobile handsets.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Hearing aid-compatible mobile handsets. 20.19... COMMERCIAL MOBILE RADIO SERVICES § 20.19 Hearing aid-compatible mobile handsets. (a) Scope of section..., consistent with its own marketing practices. However, if a manufacturer assigns different model device...

  13. How to improve cord blood engraftment?

    Directory of Open Access Journals (Sweden)

    Meral eBeksac

    2016-02-01

    Full Text Available Various factors make cord blood (CB a significant source of hematopoietic stem cells (HSC, including ease of procurement and lack of donor attrition, with the ability to process and store the donor cells long term. Importantly, high proliferative potential of the immature HSCs allows one log less use of cells compared to bone marrow (BM or peripheral blood stem cells. As total nucleated cell (TNC and CD34 + cell content of CB grafts are correlated with engraftment rate and speed, strategies to expand HSC and homing have been developed. This chapter will focus on modalities such as intra-bone administration, fucosylation, CD26 inhibition, Prostaglandin G2 derivative or complement 3 exposure and SDF-1/CXCR4/CXCL-12 pathway interventions that have been experimented successfully. Furthermore increasing evidence in line with better recognition of CB progenitors that are involved in engraftment and homing will also be addressed.

  14. An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes.

    Science.gov (United States)

    Hu, Ruiqiang; Li, Chengwei

    2015-01-01

    Automated closed-loop insulin infusion therapy has been studied for many years. In closed-loop system, the control algorithm is the key technique of precise insulin infusion. The control algorithm needs to be designed and validated. In this paper, an improved PID algorithm based on insulin-on-board estimate is proposed and computer simulations are done using a combinational mathematical model of the dynamics of blood glucose-insulin regulation in the blood system. The simulation results demonstrate that the improved PID algorithm can perform well in different carbohydrate ingestion and different insulin sensitivity situations. Compared with the traditional PID algorithm, the control performance is improved obviously and hypoglycemia can be avoided. To verify the effectiveness of the proposed control algorithm, in silico testing is done using the UVa/Padova virtual patient software.

  15. Importance of Adding Wheat Germ in Diets of Growing Goats to Improve Some Components of Blood and Growth Performance

    International Nuclear Information System (INIS)

    El-Tarabany, A.A.; Teama, F.E.I.

    2013-01-01

    This experiment was conducted to study the importance of supplementing wheat germ to the diet of growing local goats in Egypt for improving their some blood biochemical components as well as growth performance. Forty goats with 4 months age and average initial body weight 5 ± 0.5 kg were used in the present study which lasted 5 months. The animals were divided randomly into two equal groups; the 1st group fed basic diet without supplement (control) and the 2nd group of animals fed on the same basic diet with supplemented wheat germ at the rate of 5 g/head/day. The body weight was recorded at the beginning and the end of the experiment to calculate the daily gain of body weight for each animal. Blood samples were withdrawn at the end of experiment to estimate some blood parameters concentrations including total protein, albumin, globulin, urea, creatinine, total cholesterol, Ca, P, Mg, Zn, immunoglobulin G (IgG), total antioxidants and triiodothyronine (T3). The results showed that the addition of wheat germ by the rate of 5 gm/ head/ day to the diet of growing goats significantly increased the concentrations of total proteins, globulin, phosphorus, magnesium and zinc and led to significant decrease in the levels of total cholesterol. Significant improvement in levels of IgG, total antioxidants and T3 hormone in the blood were also observed. In addition, there was significant improvement in the feed efficiency of growing goats although total and daily gains of treated animals were affected by the diet supplement. It could be concluded that addition of wheat germ (5 g/head/day) led to modification of all studied blood components and led to improved feed efficiency in growing local goats, therefore, it could be recommended to use the wheat germ in growth stages because the economic return to this addition is preferable.

  16. Experts: hospitals can improve care, save health care dollars by cracking down on unnecessary blood transfusions.

    Science.gov (United States)

    2013-01-01

    Leading health care quality organizations say that blood transfusions are among the most overused treatments. The problem wastes a precious resource as well as health care dollars, continues to stretch what is known to be in short supply in some parts of the country. Part of the problem is continued adherence to an outdated medical practice that calls for transfusions when they are not medically necessary. Also, experts say many guidelines are vague regarding hemoglobin triggers. However, education coupled with IT-driven interventions can help hospitals make dramatic improvements in their blood usage, potentially preserving blood products for patients who really need them. The American Red Cross says that blood use rose by 40% in the United States between 1994 and 2008. Studies show there is wide variation regarding when blood transfusions are called for by practitioners. The latest research suggests hemoglobin thresholds of 7 or 8 grams per deciliter are acceptable, although practitioners often call for transfusions when hemoglobin is at 10 grams per deciliter. Of particular importance to EDs, the lower hemoglobin triggers don't always apply to actively bleeding patients. Through a comprehensive blood conservation program, Eastern Maine Medical Center in Bangor, ME, has been able to nearly halve the number of patients who now receive transfusions without negatively impacting patient care. Also, the program has saved the hospital more than $5 million in blood costs.

  17. Compatible ionic liquid-cellulases system for hydrolysis of lignocellulosic biomass.

    Science.gov (United States)

    Wang, Ying; Radosevich, Mark; Hayes, Douglas; Labbé, Nicole

    2011-05-01

    Ionic liquids (ILs) have been increasingly recognized as novel solvents for dissolution and pretreatment of cellulose. However, cellulases are inactivated in the presence of ILs, even when present at low concentrations. To more fully exploit the benefits of ILs it is critical to develop a compatible IL-cellulases system in which the IL is able to effectively solubilize and activate the lignocellulosic biomass, and the cellulases possess high stability and activity. In this study, we investigated the stability and activity of a commercially available cellulases mixture in the presence of different concentrations of 1-ethyl-3-methylimidazolium acetate ([Emim][OAc]). A mixture of cellulases and β-glucosidase (Celluclast1.5L, from Trichoderma reesei, and Novozyme188, from Aspergillus niger, respectively) retained 77% and 65% of its original activity after being pre-incubated in 15% and 20% (w/v) IL solutions, respectively, at 50°C for 3 h. The cellulases mixture also retained high activity in 15% [Emim][OAc] to hydrolyze Avicel, a model substrate for cellulose analysis, with conversion efficiency of approximately 91%. Notably, the presence of different amounts of yellow poplar lignin did not interfere significantly with the enzymatic hydrolysis of Avicel. Using this IL-cellulase system (15% [Emim][OAc]), the saccharification of yellow poplar biomass was also significantly improved (33%) compared to the untreated control (3%) during the first hour of enzymatic hydrolysis. Together, these findings provide compelling evidence that [Emim][OAc] was compatible with the cellulase mixture, and this compatible IL-cellulases system is promising for efficient activation and hydrolysis of native biomass to produce biofuels and co-products from the individual biomass components. Copyright © 2010 Wiley Periodicals, Inc.

  18. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  19. Effects of the prescription of reinforcing kidney, nourishing blood, improving eyesight on ARPE-19 cells induced by acrolein

    Directory of Open Access Journals (Sweden)

    Man Li

    2015-05-01

    Full Text Available AIM: To explore the effects of the prescription of reinforcing kidney, nourishing blood, improving eyesight on the oxidative stress model of ARPE-19 cells induced by acrolein. METHODS: SD rats serum containing the prescription of reinforcing kidney, nourishing blood, improving eyesight and the content of distilled water in serum were prepared. The effects of the prescription and distilled water in serum at different concentration(2.5%, 5%, 10%, 20% and 40%on cell vitality was observed by cell counting kit(CCK-8assay. the logarithmic phase of ARPE-19 cells were pretreated by different concentrations(1.25%, 2.5% and 5%of the prescription serum and distilled water in serum for 24h. Then it was treated with 75μmol/L acrolein for 24h. Cell vitality was observed by CCK-8 assay. The change of cell nucleus was detected by DAPI staining.RESULTS: 2.5% and 5% serum had no effect on cell viability(P>0.05, while 10%, 20%, 40% serum could inhibit cell viability(PPCONCLUSION: The prescription of reinforcing kidney, nourishing blood, improving eyesight has the protective effect on ARPE-19 cell damage induced by acrolein.

  20. Compatibility and kidney transplantation: The way to go.

    Directory of Open Access Journals (Sweden)

    Ilias I.N. eDoxiadis

    2012-05-01

    Full Text Available Long lasting debates in the past questioned the relevance of any sort of compatibility in post mortal kidney transplantation. It is for no say that fully compatible transplants have the highest chances for a long patient and graft survival. In the present report the use of HLA-DR as a representative of the Major Histocompatibility Complex class II genes in the allocation of organs is discussed. The major arguments are the easiness to offer to patients a compatible graft in a relatively short waiting time, an increase in graft survival, the less sensitization during the transplantation period, and the lower waiting time for a retransplant. Even if the number of organ donors remains the same a lowering of the mean waiting time is expected because of the longer period of graft survival.

  1. Cell Adhesion Selectivity of Stent Material to improve Bio-functionality by Ion Beam Modification

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jaesang; Park, JUngchan; Jung, Myunghwan; Kim, Yongki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Junkyu [Bio alpha., Co. Ltd., Gimhae (Korea, Republic of)

    2014-05-15

    In this study, ion implantation into collagen coated Co-Cr alloy, which is a cheaper material of the artificial stent product comparing with Ti alloy, has been studied to develop small diameter artificial stent by the cell adhesion control. The size of stent was 1.6mm of the diameter and 18mm of the length. The life-time of artificial stent depends on adhesion property of endothelial-cells. We successfully controlled cell adhesion selectivity between endothelial cell and muscle cell by using collagen coated and He{sup +} ion beam irradiated Co-Cr-alloy to apply to artificial stent. But, we did not achieve the inhibition of platelet adhesion, yet by using collagen coating and He{sup +} ion beam irradiation. Based on this study, we have plan to research about separation between collagen coating effect and ion beam effect. Also, we will have more detail analysis of the mechanism of cell attachment. In recent years, ion implantation has been applied to the surface modification of prosthesis to improve blood compatibility and tissue compatibility in field of biomedical application. As well known, bio compatibility was concerned with the cell adhesion selectivity for bio-functionality. The biomedical application of ion beam technology would be used more widely in the future such as catheter and artificial graft.

  2. Cell Adhesion Selectivity of Stent Material to improve Bio-functionality by Ion Beam Modification

    International Nuclear Information System (INIS)

    Lee, Jaesang; Park, JUngchan; Jung, Myunghwan; Kim, Yongki; Park, Junkyu

    2014-01-01

    In this study, ion implantation into collagen coated Co-Cr alloy, which is a cheaper material of the artificial stent product comparing with Ti alloy, has been studied to develop small diameter artificial stent by the cell adhesion control. The size of stent was 1.6mm of the diameter and 18mm of the length. The life-time of artificial stent depends on adhesion property of endothelial-cells. We successfully controlled cell adhesion selectivity between endothelial cell and muscle cell by using collagen coated and He + ion beam irradiated Co-Cr-alloy to apply to artificial stent. But, we did not achieve the inhibition of platelet adhesion, yet by using collagen coating and He + ion beam irradiation. Based on this study, we have plan to research about separation between collagen coating effect and ion beam effect. Also, we will have more detail analysis of the mechanism of cell attachment. In recent years, ion implantation has been applied to the surface modification of prosthesis to improve blood compatibility and tissue compatibility in field of biomedical application. As well known, bio compatibility was concerned with the cell adhesion selectivity for bio-functionality. The biomedical application of ion beam technology would be used more widely in the future such as catheter and artificial graft

  3. Elements of a compatible optimization theory for coupled systems; Elements d'une theorie de l'optimisation compatible de systemes couples

    Energy Technology Data Exchange (ETDEWEB)

    Bonnemay, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The first theory deals with the compatible optimization in coupled systems. A game theory for two players and with a non-zero sum is first developed. The conclusions are then extended to the case of a game with any finite number of players. After this essentially static study, the dynamic aspect of the problem is applied to the case of games which evolve. By applying PONTRYAGIN maximum principle it is possible to derive a compatible optimisation theorem which constitutes a necessary condition. (author) [French] La premiere these traite de l'optimalisation compatible des systemes couples. Une theorie du jeu a deux joueurs et a somme non nulle est d'abord developpee. Ses conclusions sont etendues ensuite au jeu a un nombre fini quelconque de joueurs. Apres cette etude essentiellement statique, l'aspect dynamique du probleme est introduit dans les jeux evolutifs. L'application du principe du maximum de PONTRYAGIN permet d'enoncer un theoreme d'optimalite compatible qui constitue une condition necessaire. (auteur)

  4. The effect of ABO blood incompatibility on corneal transplant failure in conditions with low-risk of graft rejection.

    Science.gov (United States)

    Dunn, Steven P; Stark, Walter J; Stulting, R Doyle; Lass, Jonathan H; Sugar, Alan; Pavilack, Mark A; Smith, Patricia W; Tanner, Jean Paul; Dontchev, Mariya; Gal, Robin L; Beck, Roy W; Kollman, Craig; Mannis, Mark J; Holland, Edward J

    2009-03-01

    To determine whether corneal graft survival over a 5-year follow-up period was affected by ABO blood type compatibility in participants in the Cornea Donor Study undergoing corneal transplantation principally for Fuchs dystrophy or pseudophakic corneal edema, conditions at low-risk for graft rejection. Multi-center prospective, double-masked, clinical trial. ABO blood group compatibility was determined for 1,002 donors and recipients. During a 5-year follow-up period, episodes of graft rejection were documented, and graft failures were classified as to whether or not they were attributable to immunologic rejection. Endothelial cell density was determined by a central reading center for a subset of subjects. ABO donor-recipient incompatibility was not associated with graft failure attributable to any cause including graft failure because of rejection, or with the occurrence of a rejection episode. The 5-year cumulative incidence of graft failure attributable to rejection was 32 (6%) for recipients with ABO recipient-donor compatibility and 12 (4%) for those with ABO incompatibility (hazard ratio, 0.65; 95% confidence interval, 0.33 to 1.25; P = .20). The 5-year incidence for a definite rejection episode, irrespective of whether graft failure ultimately occurred, was 64 (12%) for ABO compatible compared with 25 (8%) for ABO incompatible cases (P = .09). Among clear grafts at 5 years, percent loss of endothelial cells was similar in ABO compatible and incompatible cases. In patients undergoing penetrating keratoplasty for Fuchs dystrophy or pseudophakic corneal edema, ABO matching is not indicated since ABO incompatibility does not increase the risk of transplant failure attributable to graft rejection.

  5. A common fixed point theorem for weakly compatible mappings in Menger probabilistic quasi metric space

    Directory of Open Access Journals (Sweden)

    Badridatt Pant

    2014-02-01

    Full Text Available In this paper, we prove a common fixed point theorem for finite number of self mappings in Menger probabilistic quasi metric space. Our result improves and extends the results of Rezaiyan et al. [A common fixed point theorem in Menger probabilistic quasi-metric spaces, Chaos, Solitons and Fractals 37 (2008 1153-1157.], Miheţ [A note on a fixed point theorem in Menger probabilistic quasi-metric spaces, Chaos, Solitons and Fractals 40 (2009 2349-2352], Pant and Chauhan [Fixed points theorems in Menger probabilistic quasi metric spaces using weak compatibility, Internat. Math. Forum 5 (6 (2010 283-290] and Sastry et al. [A fixed point theorem in Menger PQM-spaces using weak compatibility, Internat. Math. Forum 5 (52 (2010 2563-2568

  6. The study on compatibility of polymer matrix resins with liquid oxygen

    International Nuclear Information System (INIS)

    Wang Ge; Li Xiaodong; Yan Rui; Xing Suli

    2006-01-01

    Liquid oxygen (LOX) polymer composite tank is very important in the development of next generation of launch vehicles. To study LOX compatible polymeric matrix resins, three kinds of epoxy resins were studied. LOX impact test was used to evaluate polymers' compatibility with LOX. Thermogravimetric analysis was used to analyze polymers' oxidation. It seemed that polymers with better anti-oxidation properties, characterized by lower oxidation weight gain, lower weight loss and lower flash point, behaved better LOX compatibility. Fourier transform infrared attenuated total reflection spectroscopy confirmed the chemical reactions during the LOX impact process on the surface of polymers were similar to the oxidation reaction in gaseous oxygen (GOX) at high temperatures, which indicated the chemical mechanism of LOX compatibility of polymers was just oxidation reaction. In this way, two new epoxy resins with desirable LOX compatibility were acquired by modification

  7. Materials compatibility information data bank

    International Nuclear Information System (INIS)

    Mead, K.E.

    1977-01-01

    A major concern in the design of weapons systems is the compatibility of the materials used with each other and with the enclosed environment. Usually these systems require long term storage with a high reliability for proper function at the end of this storage period. Materials selection is then based on both past experience and laboratory accelerated aging experiments to assure this long term reliability. To assist in the task of materials selection a computerized materials compatibility data bank is being established. This data bank will provide a source of annotated information and references to personnel and documents for both the designer and materials engineer to draw on for guidance in materials selection. The data bank storage and information retrieval philosophy will be discussed and procedures for information gathering outlined. Examples of data entries and search routines will be presented to demonstrate the usefulness and versatility of the proposed system

  8. Transplantation of Normal Adipose Tissue Improves Blood Flow and Reduces Inflammation in High Fat Fed Mice With Hindlimb Ischemia

    Directory of Open Access Journals (Sweden)

    Liyuan Chen

    2018-03-01

    Full Text Available Background: Fat deposition is associated with peripheral arterial disease. Adipose tissue has recently been implicated in vascular remodeling and angiogenic activity. We hypothesized that the transplantation of adipose tissues from normal mice improves blood flow perfusion and neovascularization in high-fat diet fed mice.Methods: After 14 weeks of high-fat diet (HFD-fed mice, unilateral hind limb ischemia was performed. Subcutaneous white adipose tissue (WAT and brown adipose tissue (BAT fat pads were harvested from normal EGFP mice, and subcutaneously transplanted over the region of the adductor muscles of HFD mice. Blood flow was measured using Laser Doppler Scanner. Vascular density, macrophages infiltration, and macrophage polarization were examined by RT-qPCR, and immunohistochemistry.Results: We found that the transplantation of WAT derived from normal mice improved functional blood flow in HFD-fed mice compared to mice transplanted with BAT and sham-treated mice. WAT transplantation increased the recruitment of pericytes associated with nascent blood vessels, but did not affect capillary formation. Furthermore, transplantation of WAT ameliorated HFD-induced insulin resistance, M2 macrophage predominance and the release of arteriogenic factors in ischemic muscles. Mice receiving WAT also displayed a marked reduction in several proinflammatory cytokines. In contrast, mice transplanted with BAT were glucose intolerant and demonstrated increased IL-6 levels in ischemic muscles.Conclusion: These results indicate that transplantation of adipose tissue elicits improvements in blood perfusion and beneficial effects on systemic glucose homeostasis and could be a promising therapeutic option for the treatment of diabetic peripheral arterial disease.

  9. Dissociating Compatibility Effects and Distractor Costs in the Additional Singleton Paradigm

    Directory of Open Access Journals (Sweden)

    Charles eFolk

    2013-07-01

    Full Text Available The interpretation of identity compatibility effects associated with irrelevant items outside the nominal focus of attention has fueled much of the debate over early versus late selection and perceptual load theory. However, compatibility effects have also played a role in the debate over the extent to which the involuntary allocation of spatial attention (i.e., attentional capture is completely stimulus-driven or whether it is contingent on top-down control settings. For example, in the context of the additional singleton paradigm, irrelevant color singletons have been found to produce not only an overall cost in search performance but also significant compatibility effects. This combination of search costs and compatibility effects has been taken as evidence that spatial attention is indeed allocated in a bottom-up fashion to the salient but irrelevant singletons. However, it is possible that compatibility effects in the additional singleton paradigm reflect parallel processing of identity associated with low perceptual load rather than an involuntary shift of spatial attention. In the present experiments, manipulations of load were incorporated into the traditional additional singleton paradigm. Under low load conditions, both search costs and compatibility effects were obtained, replicating previous studies. Under high load conditions, search costs were still present, but compatibility effects were eliminated. This dissociation suggests that the costs associated with irrelevant singletons may reflect filtering processes rather than the allocation of spatial attention.

  10. The compatibility between extension aims of staff and their ...

    African Journals Online (AJOL)

    This pilot investigation was done to investigate the compatibility between extension aims of extension staff and those of their employer. It shows that only 50 percent of respondents have an acceptable understanding of the official aims (vision), and that none of the components of the official vision has sufficient compatibility ...

  11. Evaluation of absorbed dose-distribution in the X-ray or gamma-irradiator for blood products

    International Nuclear Information System (INIS)

    Moriyama, Satoshi; Kurihara, Katsuhiko; Yokokawa, Nobuhiko; Satake, Masahiro; Juji, Takeo

    2001-01-01

    Irradiation of blood products abrogates the proliferation of lymphocytes present in cellular component, which is currently the only accepted methodology to prevent transfusion-associated graft versus host disease (TA-GVHD). A range of irradiation dose levels between 15 Gy and 50 Gy is being used, but the majority of facilities are employing 15 Gy. It should, however, be recognized that the delivered dose in the instrument canister might differ from the actual dose absorbed by the blood bag. This study have evaluated the actual dose distribution under practical conditions where a container was loaded with blood products or water bags, or filled with distilled water. This approach provides data that the maximum attenuation occurred when the container was completely filled with a blood-compatible material. Thus, an error of approximately 20 percent should be considered in the dose measured in the in-air condition. A dose calibration in an in-air condition may lead to substantial underexposure of the blood products. A dose distribution study using adequately prearranged exposure period verified that the absorbed dose of 15 Gy was attained at any point in the container for both linear accelerator and gamma-irradiator. The maximal difference in the absorbed dose between measured points was 1.5- and 1.6-fold for linear accelerator and gamma-irradiator, respectively. In conclusion, using blood-compatible materials, a careful dose calibration study should be employed in which the absorbed dose of 15 Gy is obtained at the point where the lowest dose could be expected. (author)

  12. An improved method based on wavelet coefficient correlation to filter noise in Doppler ultrasound blood flow signals

    Science.gov (United States)

    Wan, Renzhi; Zu, Yunxiao; Shao, Lin

    2018-04-01

    The blood echo signal maintained through Medical ultrasound Doppler devices would always include vascular wall pulsation signal .The traditional method to de-noise wall signal is using high-pass filter, which will also remove the lowfrequency part of the blood flow signal. Some scholars put forward a method based on region selective reduction, which at first estimates of the wall pulsation signals and then removes the wall signal from the mixed signal. Apparently, this method uses the correlation between wavelet coefficients to distinguish blood signal from wall signal, but in fact it is a kind of wavelet threshold de-noising method, whose effect is not so much ideal. In order to maintain a better effect, this paper proposes an improved method based on wavelet coefficient correlation to separate blood signal and wall signal, and simulates the algorithm by computer to verify its validity.

  13. Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.

    Science.gov (United States)

    Tsekos, Nikolaos V; Khanicheh, Azadeh; Christoforou, Eftychios; Mavroidis, Constantinos

    2007-01-01

    The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.

  14. In vitro studies of PBT Nonwoven Fabrics adsorbent for the removal of low density lipoprotein from hyperlipemia plasma

    Energy Technology Data Exchange (ETDEWEB)

    Cao Ye; Wang Hong [Institute of Blood Transfusion, Chinese Academy of Medical Sciences and Peking Union Medical College, Chengdu 610052 (China); Yang Chao [State Key Lab of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); Zhong Rui [Institute of Blood Transfusion, Chinese Academy of Medical Sciences and Peking Union Medical College, Chengdu 610052 (China); Lei Yu [Chengdu Blood Center, Chengdu 610041 (China); Sun Kang [State Key Lab of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); Liu Jiaxin, E-mail: jxliu8122@vip.sina.com [Institute of Blood Transfusion, Chinese Academy of Medical Sciences and Peking Union Medical College, Chengdu 610052 (China)

    2011-06-15

    Polyanion ligands such as acrylic acid (AA) and heparin were grafted on PBT Nonwoven Fabrics (PBTNF) to study their effect on the adsorption of low density lipoprotein (LDL). These modified PBTNFs were characterized by Horizontal Attenuated Total Reflectance Fourier Transform Infrared spectroscopy and X-ray Photoelectron spectroscopy. The blood compatibilities of the modified PBTNFs were examined using in vitro hemolysis rate (HR), platelet adhesion, total protein (TP) and activated partial thromboplastin time. The results showed that direct immobilized heparin could improve PBTNF-PAA's blood compatibility and decrease the adsorption capability of useful high density lipoprotein, but would possess so low bioactivity that could not further improve the absorption of LDL and TC. Since the PBTNF-PAA55-Heparin adsorbent had quite good adsorption selectivity for these proteins, it can be an excellent candidate for depletion of LDL with good blood compatibility.

  15. High-speed imaging of blood splatter patterns

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E.; Albright, K.A.; King, N.S.P.; Yates, G.J. (Los Alamos National Lab., NM (United States)); Levine, G.F. (California Dept. of Justice, Sacramento, CA (United States). Bureau of Forensic Services)

    1993-01-01

    The interpretation of blood splatter patterns is an important element in reconstructing the events and circumstances of an accident or crime scene. Unfortunately, the interpretation of patterns and stains formed by blood droplets is not necessarily intuitive and study and analysis are required to arrive at a correct conclusion. A very useful tool in the study of blood splatter patterns is high-speed photography. Scientists at the Los Alamos National Laboratory, Department of Energy (DOE), and Bureau of Forensic Services, State of California, have assembled a high-speed imaging system designed to image blood splatter patterns. The camera employs technology developed by Los Alamos for the underground nuclear testing program and has also been used in a military mine detection program. The camera uses a solid-state CCD sensor operating at approximately 650 frames per second (75 MPixels per second) with a microchannel plate image intensifier that can provide shuttering as short as 5 ns. The images are captured with a laboratory high-speed digitizer and transferred to an IBM compatible PC for display and hard copy output for analysis. The imaging system is described in this paper.

  16. High-speed imaging of blood splatter patterns

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E.; Albright, K.A.; King, N.S.P.; Yates, G.J. [Los Alamos National Lab., NM (United States); Levine, G.F. [California Dept. of Justice, Sacramento, CA (United States). Bureau of Forensic Services

    1993-05-01

    The interpretation of blood splatter patterns is an important element in reconstructing the events and circumstances of an accident or crime scene. Unfortunately, the interpretation of patterns and stains formed by blood droplets is not necessarily intuitive and study and analysis are required to arrive at a correct conclusion. A very useful tool in the study of blood splatter patterns is high-speed photography. Scientists at the Los Alamos National Laboratory, Department of Energy (DOE), and Bureau of Forensic Services, State of California, have assembled a high-speed imaging system designed to image blood splatter patterns. The camera employs technology developed by Los Alamos for the underground nuclear testing program and has also been used in a military mine detection program. The camera uses a solid-state CCD sensor operating at approximately 650 frames per second (75 MPixels per second) with a microchannel plate image intensifier that can provide shuttering as short as 5 ns. The images are captured with a laboratory high-speed digitizer and transferred to an IBM compatible PC for display and hard copy output for analysis. The imaging system is described in this paper.

  17. Nattokinase improves blood flow by inhibiting platelet aggregation and thrombus formation.

    Science.gov (United States)

    Jang, Ja-Young; Kim, Tae-Su; Cai, Jingmei; Kim, Jihyun; Kim, Youngeun; Shin, Kyungha; Kim, Kwang Sei; Park, Sung Kyeong; Lee, Sung-Pyo; Choi, Ehn-Kyoung; Rhee, Man Hee; Kim, Yun-Bae

    2013-12-01

    The effects of nattokinase on the in vitro platelet aggregation and in vivo thrombosis were investigated in comparison with aspirin. Rabbit platelet-rich plasma was incubated with nattokinase and aggregation inducers collagen and thrombin, and the platelet aggregation rate was analyzed. Nattokinase significantly inhibited both the collagen- and thrombin-induced platelet aggregations. Nattokinase also reduced thromboxane B2 formation from collagen-activated platelets in a concentration-dependent manner. Rats were orally administered with nattokinase for 1 week, and their carotid arteries were exposed. Arterial thrombosis was induced by applying 35% FeCl3-soaked filter paper for 10 min, and the blood flow was monitored with a laser Doppler probe. Nattokinase delayed the FeCl3-induced arterial occlusion in a dose-dependent manner, doubling the occlusion time at 160 mg/kg. In addition, a high dose (500 mg/kg) of nattokinase fully prevented the occlusion, as achieved with aspirin (30 mg/kg). The results indicate that nattokinase extracted from fermented soybean inhibit platelet aggregation by blocking thromboxane formation, and thereby delay thrombosis following oxidative arterial wall injury. Therefore, it is suggested that nattokinase could be a good candidate without adverse effects for the improvement of blood flow.

  18. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  19. Development of blood irradiators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is designed to improve the techniques of blood irradiation through the development of improved and portable blood irradiators. A portable blood irradiator, consisting of a vitreous carbon body and thulium-170 radiation source, was attached to dogs via a carotid-jugular shunt, and its effects on the immune system measured. The device has demonstrated both significant suppression of circulating lymphocytes and prolonged retention of skin allografts

  20. Waste compatibility assessments to support project W-320

    International Nuclear Information System (INIS)

    BLAAK, T.M.

    1999-01-01

    The intent of this internal memo is to provide a recommendation for the transfer of tank 241-C-106 waste, Attachment 2, to tank 241-AY-102. This internal memo also identifies additional requirements which have been deemed necessary for safely receiving and storing the waste documented in Attachment 2 from tank 241-C-106 in tank 241-AY-102. This waste transfer is planned in support of tank 241-C-106 solids sluicing activities. Approximately 200,000 gallons of waste and flush water are expected to be pumped from tank 241-C-106 into tank 241-AY-102. Several transfers will be necessary to complete the sluicing of tank 241-C-106 solids. To assure ourselves that this waste transfer will not create any compatibility concerns, a waste compatibility assessment adhering to current waste compatibility requirements has been performed

  1. Follow-up of Antihypertensive Therapy Improves Blood Pressure Control: Results of HYT (HYperTension survey) Follow-up.

    Science.gov (United States)

    Fici, F; Seravalle, G; Koylan, N; Nalbantgil, I; Cagla, N; Korkut, Y; Quarti-Trevano, F; Makel, W; Grassi, G

    2017-09-01

    Although improved during the past few years, blood pressure control remains sub optimal. The impact of follow-up assessment on blood pressure control was evaluated in a group of patients of the HYT (HYperTension survey), treated with a combination of different dihydropyridine calcium-channel blockers (CCBs regimen) and inhibitors of renin-angiotensin-aldosterone system (RAAS) and with uncontrolled blood pressure. This was obtained assessing (a) the rate of blood pressure control at 3 and 6 months of follow-up in the whole group of patients, (b) the rate of blood pressure control and the average blood pressure values in subjects treated with different DHP-CCBs regimen. From the 4993 patients with uncontrolled blood pressure, (BP ≥ 140/90 or ≥140/85 in patients with diabetes), 3729 (mean age 61.2 ± 11.5 years), maintained CCBs regimen combined wih RAAS blockers and were evaluated at 3 and 6 months follow-up. At each visit BP (semiautomatic device, Omron-M6, 3 measurements), heart rate, adverse events and treatment persistence were collected. At 1st and 2nd follow-up the rate of controlled BP was 63.5 and 72.8% respectively (p blood pressure control; (b) there is no significant difference in the antihypertensive effect between different CCBs regimen; (c) lipophilic CCBs induce less ankle edema.

  2. Emerging risks and outcomes of blood transfusion in surgery.

    Science.gov (United States)

    Shander, Aryeh

    2004-01-01

    Prior to 1900, blood transfusions were fraught with danger and often caused more complications than the underlying disease. Discovery of the ABO compatibility system in the early twentieth century opened the modern era of blood transfusion, yet ABO incompatibility-as a result of clerical error-remains a significant threat to the recipient today. The risk of disease transmission now includes new and emerging agents, such as Trepanosoma cruzii and West Nile Virus (WNV), as well as other existing pathogens. Transfusion-related immunomodulation (TRIM) presents a further risk to recipient patients. Confounding these problems are shortages of safe blood and the accelerated rise in the cost of blood due to increased testing. Outcome data on transfusion therapy have not always been favorable, particularly in the areas of postoperative infection, systemic inflammatory response syndrome (SIRS), multiple organ failure (MOF), and mortality. Such data have generated extensive efforts to determine association versus underlying cause of post-transfusion complications. In addition, unprecedented global initiatives to minimize the use of allogeneic blood are on the way. Options may include, but are not limited to, the use of "blood substitutes," although validation of such products is still required. In the meantime, blood product conservation techniques should become part of routine transfusion medicine.

  3. Low-Intensity Sprint Training With Blood Flow Restriction Improves 100-m Dash.

    Science.gov (United States)

    Behringer, Michael; Behlau, Daniel; Montag, Johannes C K; McCourt, Molly L; Mester, Joachim

    2017-09-01

    Behringer, M, Behlau, D, Montag, JCK, McCourt, ML, and Mester, J. Low-intensity sprint training with blood flow restriction improves 100-m dash. J Strength Cond Res 31(9): 2462-2472, 2017-We investigated the effects of practical blood flow restriction (pBFR) of leg muscles during sprint training on the 100-m dash time in well-trained sport students. Participants performed 6 × 100-m sprints at 60-70% of their maximal 100-m sprinting speed twice a week for 6 weeks, either with (intervention group [IG]; n = 12) or without pBFR (control group [CG]; n = 12). The 100-m dash time significantly decreased more in the IG (-0.38 ± 0.24 seconds) than in the CG (-0.16 ± 0.17 seconds). The muscle thickness of the rectus femoris increased only in the IG, whereas no group-by-time interactions were found for the muscle thickness of the biceps femoris and the biceps brachii. The maximal isometric force, measured using a leg press, did not change in either group. However, the rate of force development improved in the IG. Growth hormone, testosterone, insulin-like growth factor 1, and cortisol concentrations did not significantly differ between both groups at any measurement time point (pre, 1 minute, 20 minutes, 120 minutes, and 24 hours after the 6 all-out sprints of the first training session). The muscle damage marker h-FABP increased significantly more in the CG than in the IG. The pBFR improved the 100-m dash time significantly more than low-intensity sprint interval training alone. Other noted benefits of training with pBFR were a decreased level of muscle damage, a greater increase of the rectus femoris muscle thickness, and a higher rate of force development. However, the tested hormones were unable to explain the additional beneficial effects.

  4. Spectroscopic microvascular blood detection from the endoscopically normal colonic mucosa: biomarker for neoplasia risk.

    Science.gov (United States)

    Roy, Hemant K; Gomes, Andrew; Turzhitsky, Vladimir; Goldberg, Michael J; Rogers, Jeremy; Ruderman, Sarah; Young, Kim L; Kromine, Alex; Brand, Randall E; Jameel, Mohammed; Vakil, Parmede; Hasabou, Nahla; Backman, Vadim

    2008-10-01

    We previously used a novel biomedical optics technology, 4-dimensional elastically scattered light fingerprinting, to show that in experimental colon carcinogenesis the predysplastic epithelial microvascular blood content is increased markedly. To assess the potential clinical translatability of this putative field effect marker, we characterized the early increase in blood supply (EIBS) in human beings in vivo. We developed a novel, endoscopically compatible, polarization-gated, spectroscopic probe that was capable of measuring oxygenated and deoxygenated (Dhb) hemoglobin specifically in the mucosal microcirculation through polarization gating. Microvascular blood content was measured in 222 patients from the endoscopically normal cecum, midtransverse colon, and rectum. If a polyp was present, readings were taken from the polyp tissue along with the normal mucosa 10-cm and 30-cm proximal and distal to the lesion. Tissue phantom studies showed that the probe had outstanding accuracy for hemoglobin determination (r(2) = 0.99). Augmentation of microvasculature blood content was most pronounced within the most superficial ( approximately 100 microm) layer and dissipated in deeper layers (ie, submucosa). EIBS was detectable within 30 cm from the lesion and the magnitude mirrored adenoma proximity. This occurred for both oxygenated hemoglobin and DHb, with the effect size being slightly greater for DHb. EIBS correlated with adenoma size and was not engendered by nonneoplastic (hyperplastic) polyps. We show, herein, that in vivo microvascular blood content can be measured and provides an accurate marker of field carcinogenesis. This technological/biological advance has numerous potential applications in colorectal cancer screening such as improved polyp detection and risk stratification.

  5. Image quality associated with the use of an MR-compatible incubator in neonatal neuroimaging.

    LENUS (Irish Health Repository)

    O'Regan, K

    2012-04-01

    MRI in the neonate poses significant challenges associated with patient transport and monitoring, and the potential for diminished image quality owing to patient motion. The objective of this study was to evaluate the usefulness of a dedicated MR-compatible incubator with integrated radiofrequency coils in improving image quality of MRI studies of the brain acquired in term and preterm neonates using standard MRI equipment.

  6. Mechanical compatibility and stress analyses in composite materials

    International Nuclear Information System (INIS)

    Schimmoeller, H.; Ruge, J.

    1976-01-01

    This paper gives a short description of the problem of mechanical interactions and mechanical compatibility in composite bodies. The formation of stress-strain states, caused by the mechanical compatibility by bonding of the interfaces, is discussed. The difference between the continuous and discontinuous type of material transition in the interface is described. Flat laminated materials are at first considered. For this type of composite bodies thermal stresses and thermal residual stresses are elastically-plastically calculated. (orig.) [de

  7. Chemical compatibility between cladding alloys and advanced fuels

    International Nuclear Information System (INIS)

    Fee, D.C.; Johnson, C.E.

    1975-05-01

    The National Advanced Fuels Program requires chemical, mechanical, and thermophysical properties data for cladding alloys. The compatibility behavior of cladding alloys with advanced fuels is critically reviewed. in carbide fuel pins, the principal compatibility problem is cladding carburization, diffusion of carbon into the cladding matrix accompanied by carbide precipitation. Carburization changes the mechanical properties of the cladding alloy. The extent of carburization increases in sodium (versus gas) bonded fuels. The depth of carburization increases with increasing sesquicarbide (M 2 C 3 ) content of the fuel. In nitride fuel pins, the principal compatibility problem is cladding nitriding, diffusion of nitrogen into the cladding matrix accompanied by nitride precipitation. Nitriding changes the mechanical properties of the cladding alloy. In both carbide and nitride fuel pins, fission products do not migrate appreciably to the cladding and do not appear to contribute to cladding attack. 77 references. (U.S.)

  8. The Construal (In)compatibility Effect

    DEFF Research Database (Denmark)

    Yang, Xiaojing; Ringberg, Torsten; Mao, Huifang

    2011-01-01

    incompatible with their mental construal, while ad claims construed at a level compatible with consumers' mental construal are more effective for those who possess a less creative mindset. We document that such differences in persuasion are driven by the fact that consumers with a creative (less creative) mind...

  9. Direct coordinate-free derivation of the compatibility equation for finite strains

    Science.gov (United States)

    Ryzhak, E. I.

    2014-07-01

    The compatibility equation for the Cauchy-Green tensor field (squared tensor of pure extensionwith respect to the reference configuration) is directly derived from the well-known relation expressing this tensor via the vector field determining the mapping (transformation) of the reference configuration into the actual one. The derivation is based on the use of the apparatus of coordinatefree tensor calculus and does not apply any notions and relations of Riemannian geometry at all. The method is illustrated by deriving the well-known compatibility equation for small strains. It is shown that when the obtained compatibility equation for finite strains is linearized, it becomes the compatibility equation for small strains which indirectly confirms its correctness.

  10. DOD Offshore Wind Mission Compatibility Assessments

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set represents the results of analyses conducted by the Department of Defense to assess the compatibility of offshore wind development with military assets...

  11. Blood wastage management in a regional blood transfusion centre.

    Science.gov (United States)

    Javadzadeh Shahshahani, H; Taghvai, N

    2017-10-01

    The aim of this study was to determine the rate of blood component wastage before and after interventions at Yazd Blood Transfusion Center. The growing need for blood components along with blood safety issues and rising costs constantly pressurise blood centres to improve their efficiency. Reducing the quantity of discarded blood at all stages of the supply chain can decrease the total costs. Data on discarded blood components were extracted from the database of Yazd Blood Transfusion Center. Multiple interventions, including implementation of wastage management standard operating procedures and reduction of red blood cells (RBCs) inventory level, were implemented. Discard rates of blood components in the 3 years after intervention (2013-2015) were compared with the discard rates in the 3 years before interventions. The total wastage rate of blood components decreased by almost 60%. Discard rates of RBCs, platelets and plasma decreased from 9·7%, 18·5% and 5·4% to 2·9%, 10·5% and 2·3%, (P supply saving. © 2017 British Blood Transfusion Society.

  12. Multi-damping earthquake design spectra-compatible motion histories

    International Nuclear Information System (INIS)

    Choi, Dong-Ho; Lee, Sang-Hoon

    2003-01-01

    Two iterative methods of developing time histories compatible with multi-damping spectra are presented. The common method of forcing agreement among design and calculated spectral values at several frequencies and multiple damping values may give poor, even meaningless results. The two simple iterative techniques presented here use acceleration impulse functions for 'correcting' the time histories. In the first method the correction is calculated separately for each frequency and damping value and the maximum corresponding coefficient is used to correct the time history for the iteration. In the second method the solution is further improved by introducing a scale factor at each iteration. The effectiveness of the proposed techniques is illustrated by a comparison of a set of six multi-damping design spectra with spectral responses of a time history

  13. Hydrophobic Modification of Layered Clays and Compatibility for Epoxy Nanocomposites

    Directory of Open Access Journals (Sweden)

    Jiang-Jen Lin

    2010-04-01

    Full Text Available Recent studies on the intercalation and exfoliation of layered clays with polymeric intercalating agents involving poly(oxypropylene-amines and the particular uses for epoxy nanocomposites are reviewed. For intercalation, counter-ionic exchange reactions of clays including cationic layered silicates and anionic Al-Mg layered double hydroxide (LDH with polymeric organic ions afforded organoclays led to spatial interlayer expansion from 12 to 92 Å (X-ray diffraction as well as hydrophobic property. The inorganic clays of layered structure could be modified by the poly(oxypropyleneamine-salts as the intercalating agents with molecular weights ranging from 230 to 5,000 g/mol. Furthermore, natural montmorillonite (MMT clay could be exfoliated into thin layer silicate platelets (ca. 1 nm thickness in one step by using polymeric types of exfoliating agents. Different lateral dimensions of MMT, synthetic fluorinated Mica and LDH clays had been cured into epoxy nanocomposites. The hydrophobic amine-salt modification resulting in high spacing of layered or exfoliation of individual clay platelets is the most important factor for gaining significant improvements of properties. In particular, these modified clays were reported to gain significant improvements such as reduced coefficient of thermal expansion (CTE, enhanced thermal stability, and hardness. The utilization of these layered clays for initiating the epoxy self-polymerization was also reported to have a unique compatibility between clay and organic resin matrix. However, the matrix domain lacks of covalently bonded crosslink and leads to the isolation of powder material. It is generally concluded that the hydrophobic expansion of the clay inter-gallery spacing is the crucial step for enhancing the compatibility and the ultimate preparation of the advanced epoxy materials.

  14. Hydrophobic Modification of Layered Clays and Compatibility for Epoxy Nanocomposites

    Science.gov (United States)

    Lin, Jiang-Jen; Chan, Ying-Nan; Lan, Yi-Fen

    2010-01-01

    Recent studies on the intercalation and exfoliation of layered clays with polymeric intercalating agents involving poly(oxypropylene)-amines and the particular uses for epoxy nanocomposites are reviewed. For intercalation, counter-ionic exchange reactions of clays including cationic layered silicates and anionic Al-Mg layered double hydroxide (LDH) with polymeric organic ions afforded organoclays led to spatial interlayer expansion from 12 to 92 Å (X-ray diffraction) as well as hydrophobic property. The inorganic clays of layered structure could be modified by the poly(oxypropylene)amine-salts as the intercalating agents with molecular weights ranging from 230 to 5,000 g/mol. Furthermore, natural montmorillonite (MMT) clay could be exfoliated into thin layer silicate platelets (ca. 1 nm thickness) in one step by using polymeric types of exfoliating agents. Different lateral dimensions of MMT, synthetic fluorinated Mica and LDH clays had been cured into epoxy nanocomposites. The hydrophobic amine-salt modification resulting in high spacing of layered or exfoliation of individual clay platelets is the most important factor for gaining significant improvements of properties. In particular, these modified clays were reported to gain significant improvements such as reduced coefficient of thermal expansion (CTE), enhanced thermal stability, and hardness. The utilization of these layered clays for initiating the epoxy self-polymerization was also reported to have a unique compatibility between clay and organic resin matrix. However, the matrix domain lacks of covalently bonded crosslink and leads to the isolation of powder material. It is generally concluded that the hydrophobic expansion of the clay inter-gallery spacing is the crucial step for enhancing the compatibility and the ultimate preparation of the advanced epoxy materials.

  15. Double Retort System for Materials Compatibility Testing

    International Nuclear Information System (INIS)

    V. Munne; EV Carelli

    2006-01-01

    With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the Space Nuclear Power Plant (SNPP) for Project Prometheus (References a and b) there was a need to investigate compatibility between the various materials to be used throughout the SNPP. Of particular interest was the transport of interstitial impurities from the nickel-base superalloys, which were leading candidates for most of the piping and turbine components to the refractory metal alloys planned for use in the reactor core. This kind of contamination has the potential to affect the lifetime of the core materials. This letter provides technical information regarding the assembly and operation of a double retort materials compatibility testing system and initial experimental results. The use of a double retort system to test materials compatibility through the transfer of impurities from a source to a sink material is described here. The system has independent temperature control for both materials and is far less complex than closed loops. The system is described in detail and the results of three experiments are presented

  16. Electromagnetic compatibility methods, analysis, circuits, and measurement

    CERN Document Server

    Weston, David A

    2016-01-01

    Revised, updated, and expanded, Electromagnetic Compatibility: Methods, Analysis, Circuits, and Measurement, Third Edition provides comprehensive practical coverage of the design, problem solving, and testing of electromagnetic compatibility (EMC) in electrical and electronic equipment and systems. This new edition provides novel information on theory, applications, evaluations, electromagnetic computational programs, and prediction techniques available. With sixty-nine schematics providing examples for circuit level electromagnetic interference (EMI) hardening and cost effective EMI problem solving, this book also includes 1130 illustrations and tables. Including extensive data on components and their correct implementation, the myths, misapplication, misconceptions, and fallacies that are common when discussing EMC/EMI will also be addressed and corrected.

  17. Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM.

    Science.gov (United States)

    Graves, John W; Grossardt, Brandon R

    2010-06-01

    Guidelines for office blood pressure (BP) measurements recommend two or more readings at each visit. It has been suggested that discarding the first reading may improve the diagnostic utility of office readings. We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings. We studied measurements in 313 mildly hypertensive patients (181 men, median age 51 years) at the end of the washout phase of a hypertension treatment trial. All patients had three auscultatory readings by a trained nurse using a mercury manometer before a 24-h ABPM and three automated readings (Omron 705 CP) to American Heart Association standards after ABPM. Daytime ABPM (09:00-21:00) of systolic BP and diastolic BP were compared with office methods using first only, second and third only, and all three readings. Associations were assessed using Bland-Altman plots and Pearson's correlations. Bland-Altman plots revealed no differences between office methods and daytime ABPM regardless of whether the first reading was included or discarded. Results were similar for both systolic BP and diastolic BP. The Pearson correlations of office method readings with ABPM readings were lowest using the first measurement alone; however, discarding the first measurement did not improve the correlation compared with using all three readings. Discarding the first office BP reading does not change the association of office BP with ABPM or improve the correlation with ABPM values in hypertensive patients.

  18. Investigating the factors affecting farmers' perceived compatibility of bio- fertilizers in the Zanjan county

    Directory of Open Access Journals (Sweden)

    Hesamedin Gholami

    2017-04-01

    Full Text Available The importance of bio-fertilizers has increased because of the negative consequences of using chemical fertilizers. This study that was conducted in the Zanjan County was aimed at examining the factors that affect farmers' perceived compatibility of bio- fertilizers. In this regard, among 313 active farmers in the Zanjan county, 135 farmers were contacted and surveyed through a convenient sampling to examine two categories of effective factors, i.e. personal (knowledge about and attitude toward bio-fertilizers and environmental (economic accessibility, physical accessibility to bio-fertilizers and policy and support structures factors. Binary logistic regression and discriminant analysis were applied to examine the consistency of the results. The results of two techniques showed that improving policy and support increased farmers' perceived computability and providing economic facilities decreased it. Furthermore, the results revealed that farmers' knowledge and attitude did not have a significant effect on the perceived compatibility.

  19. Improving hemocompatibility and accelerating endothelialization of vascular stents by a copper-titanium film

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hengquan, E-mail: 99xyxy@163.com [College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu 610059 (China); Pan, Changjiang [Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huaiyin 223033 (China); Zhou, Shijie; Li, Junfeng [College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu 610059 (China); Huang, Nan [Key Laboratory for Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu 610031 (China); Dong, Lihua [Department of Research & Development, Lifetech Scientific (Shenzhen) Co., Ltd, Shenzhen 518057 (China)

    2016-12-01

    Bio-inorganic films and drug-eluting coatings are usually used to improve the hemocompatibility and inhibit restenosis of vascular stent; however, above bio-performances couldn't combine together with single materials. In the present study, we reported a simple approach to fabricate a metal film with the aim of imparting the stent with good blood compatibility and accelerating endothelialization. The films with various ratios of Cu and Ti were prepared through the physical vapor deposition. Phase structure and element composition were investigated by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), respectively. The releasing volume of copper ion in Cu/Ti film was determined by immersing test. The hemolysis ratio, platelet adhesion and clotting time were applied to evaluate the hemocompatibility. The proliferative behaviors of endothelial cells and smooth muscle cells under certain copper concentration were investigated in vitro and in vivo. Results indicated that copper-titanium films exhibited good hemocompatibility in vitro; however, the increase of Cu/Ti ratio could lead to increasing hemolysis ratio. Endothelial cells displayed more proliferative than smooth muscle cells when the copper concentration was < 7.5 μg/ml, however both cells tended to apoptosis to some degree when the copper concentration was increased. The complete endothelialization of the film with low copper in vivo was observed at the 2nd week, indicating that the copper-titanium film with the lower copper concentration could promote endothelialization. Therefore, the inorganic copper-titanium film could be potential biomaterials to improve blood compatibility and accelerating endothelialization of vascular stents. - Highlight: • The Cu/Ti film with regulating the various responses of ECs and SMCs has been prepared. • The hemocompatibility of Cu/Ti film is favorable and regulatable. • The volume of copper ion released from film could be designed.

  20. Combination of blood tests for significant fibrosis and cirrhosis improves the assessment of liver-prognosis in chronic hepatitis C.

    Science.gov (United States)

    Boursier, J; Brochard, C; Bertrais, S; Michalak, S; Gallois, Y; Fouchard-Hubert, I; Oberti, F; Rousselet, M-C; Calès, P

    2014-07-01

    Recent longitudinal studies have emphasised the prognostic value of noninvasive tests of liver fibrosis and cross-sectional studies have shown their combination significantly improves diagnostic accuracy. To compare the prognostic accuracy of six blood fibrosis tests and liver biopsy, and evaluate if test combination improves the liver-prognosis assessment in chronic hepatitis C (CHC). A total of 373 patients with compensated CHC, liver biopsy (Metavir F) and blood tests targeting fibrosis (APRI, FIB4, Fibrotest, Hepascore, FibroMeter) or cirrhosis (CirrhoMeter) were included. Significant liver-related events (SLRE) and liver-related deaths were recorded during follow-up (started the day of biopsy). During the median follow-up of 9.5 years (3508 person-years), 47 patients had a SLRE and 23 patients died from liver-related causes. For the prediction of first SLRE, most blood tests allowed higher prognostication than Metavir F [Harrell C-index: 0.811 (95% CI: 0.751-0.868)] with a significant increase for FIB4: 0.879 [0.832-0.919] (P = 0.002), FibroMeter: 0.870 [0.812-0.922] (P = 0.005) and APRI: 0.861 [0.813-0.902] (P = 0.039). Multivariate analysis identified FibroMeter, CirrhoMeter and sustained viral response as independent predictors of first SLRE. CirrhoMeter was the only independent predictor of liver-related death. The combination of FibroMeter and CirrhoMeter classifications into a new FM/CM classification improved the liver-prognosis assessment compared to Metavir F staging or single tests by identifying five subgroups of patients with significantly different prognoses. Some blood fibrosis tests are more accurate than liver biopsy for determining liver prognosis in CHC. A new combination of two complementary blood tests, one targeted for fibrosis and the other for cirrhosis, optimises assessment of liver-prognosis. © 2014 John Wiley & Sons Ltd.

  1. Rust transformation/rust compatible primers

    Science.gov (United States)

    Emeric, Dario A.; Miller, Christopher E.

    1993-01-01

    Proper surface preparation has been the key to obtain good performance by a surface coating. The major obstacle in preparing a corroded or rusted surface is the complete removal of the contaminants and the corrosion products. Sandblasting has been traditionally used to remove the corrosion products before painting. However, sandblasting can be expensive, may be prohibited by local health regulations and is not applicable in every situation. To get around these obstacles, Industry developed rust converters/rust transformers and rust compatible primers (high solids epoxies). The potential use of these products for military equipment led personnel of the Belvoir Research, Development and Engineering Center (BRDEC) to evaluate the commercially available rust transformers and rust compatible primers. Prior laboratory experience with commercially available rust converters, as well as field studies in Hawaii and Puerto Rico, revealed poor performance, several inherent limitations, and lack of reliability. It was obvious from our studies that the performance of rust converting products was more dependent on the amount and type of rust present, as well as the degree of permeability of the coating, than on the product's ability to form an organometallic complex with the rust. Based on these results, it was decided that the Military should develop their own rust converter formulation and specification. The compound described in the specification is for use on a rusted surface before the application of an organic coating (bituminous compounds, primer or topcoat). These coatings should end the need for sandblasting or the removing of the adherent corrosion products. They also will prepare the surface for the application of the organic coating. Several commercially available rust compatible primers (RCP) were also tested using corroded surfaces. All of the evaluated RCP failed our laboratory tests for primers.

  2. CMOS-compatible high-voltage integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Parpia, Z

    1988-01-01

    Considerable savings in cost and development time can be achieved if high-voltage ICs (HVICs) are fabricated in an existing low-voltage process. In this thesis, the feasibility of fabricating HVICs in a standard CMOS process is investigated. The high-voltage capabilities of an existing 5-{mu}m CMOS process are first studied. High-voltage n- and p-channel transistors with breakdown voltages of 50 and 190 V, respectively, were fabricated without any modifications to the process under consideration. SPICE models for these transistors are developed, and their accuracy verified by comparison with experimental results. In addition, the effect of the interconnect metallization on the high-voltage performance of these devices is also examined. Polysilicon field plates are found to be effective in preventing premature interconnect induced breakdown in these devices. A novel high-voltage transistor structure, the insulated base transistor (IBT), based on a merged MOS-bipolar concept, is proposed and implemented. In order to enhance the high-voltage device capabilities, an improved CMOS-compatible HVIC process using junction isolation is developed.

  3. Passive heat therapy improves endothelial function, arterial stiffness and blood pressure in sedentary humans.

    Science.gov (United States)

    Brunt, Vienna E; Howard, Matthew J; Francisco, Michael A; Ely, Brett R; Minson, Christopher T

    2016-09-15

    A recent 30 year prospective study showed that lifelong sauna use reduces cardiovascular-related and all-cause mortality; however, the specific cardiovascular adaptations that cause this chronic protection are currently unknown. We investigated the effects of 8 weeks of repeated hot water immersion ('heat therapy') on various biomarkers of cardiovascular health in young, sedentary humans. We showed that, relative to a sham group which participated in thermoneutral water immersion, heat therapy increased flow-mediated dilatation, reduced arterial stiffness, reduced mean arterial and diastolic blood pressure, and reduced carotid intima media thickness, with changes all on par or greater than what is typically observed in sedentary subjects with exercise training. Our results show for the first time that heat therapy has widespread and robust effects on vascular function, and as such, could be a viable treatment option for improving cardiovascular health in a variety of patient populations, particularly those with limited exercise tolerance and/or capabilities. The majority of cardiovascular diseases are characterized by disorders of the arteries, predominantly caused by endothelial dysfunction and arterial stiffening. Intermittent hot water immersion ('heat therapy') results in elevations in core temperature and changes in cardiovascular haemodynamics, such as cardiac output and vascular shear stress, that are similar to exercise, and thus may provide an alternative means of improving health which could be utilized by patients with low exercise tolerance and/or capabilities. We sought to comprehensively assess the effects of 8 weeks of heat therapy on biomarkers of vascular function in young, sedentary subjects. Twenty young, sedentary subjects were assigned to participate in 8 weeks (4-5 times per week) of heat therapy (n = 10; immersion in a 40.5°C bath sufficient to maintain rectal temperature ≥ 38.5°C for 60 min per session) or thermoneutral water

  4. Nonclassical Symmetries for Nonlinear Partial Differential Equations via Compatibility

    International Nuclear Information System (INIS)

    El-Sabbagh, Mostafa F.; Ahmad, Ali T.

    2011-01-01

    The determining equations for the nonclassical symmetry reductions of nonlinear partial differential equations with arbitrary order can be obtained by requiring the compatibility between the original equations and the invariant surface conditions. The (2+1)-dimensional shallow water wave equation, Boussinesq equation, and the dispersive wave equations in shallow water serve as examples illustrating how compatibility leads quickly and easily to the determining equations for their nonclassical symmetries. (general)

  5. Electromagnetic compatibility in power electronics

    CERN Document Server

    Costa , François; Revol , Bertrand

    2014-01-01

    Scientists largely attribute the recent deterioration of the electromagnetic environment to power electronics. This realization has spurred the study of methodical approaches to electromagnetic compatibility designs as explored in this text. The book addresses major challenges, such as handling numerous parameters vital to predicting electro magnetic effects and achieving compliance with line-harmonics norms, while proposing potential solutions.

  6. Methodical evaluation and improvement of matrix compatible PDMS-overcoated coating for direct immersion solid phase microextraction gas chromatography (DI-SPME-GC)-based applications.

    Science.gov (United States)

    Souza-Silva, Érica A; Gionfriddo, Emanuela; Shirey, Robert; Sidisky, Len; Pawliszyn, Janusz

    2016-05-12

    The main quest for the implementation of direct SPME to complex matrices has been the development of matrix compatible coatings that provide sufficient sensitivity towards the target analytes. In this context, we present here a thorough evaluation of PDMS-overcoated fibers suitable for simultaneous extraction of different polarities analytes, while maintaining adequate matrix compatibility. For this, eleven analytes were selected, from various application classes (pesticides, industrial chemicals and pharmaceuticals) and with a wide range of log P values (ranging from 1.43 to 6). The model matrix chosen was commercial Concord grape juice, which is rich in pigments such as anthocyanins, and contains approximately 20% of sugar (w/w). Two types of PDMS, as well as other intrinsic factors associated with the PDMS-overcoated fiber fabrication are studied. The evaluation showed that the PDMS-overcoated fibers considerably slowed down the coating fouling process during direct immersion in complex matrices of high sugar content. Longevity differences could be seen between the two types of PDMS tested, with a proprietary Sylgard(®) giving superior performance because of lesser amount of reactive groups and enhanced hydrophobicity. Conversely, the thickness of the outer layer did not seem to have a significant effect on the fiber lifetime. We also demonstrate that the uniformity of the overcoated PDMS layer is paramount to the achievement of reliable data and extended fiber lifetime. Employing the optimum overcoated fiber, limits of detection (LOD) in the range of 0.2-1.3 ng/g could be achieved. Additional improvement is attainable by introducing washing of the coatings after desorption, so that any carbon build-up (fouling) left on the coating surface after thermal desorption can be removed. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  8. Hibiscus sabdariffa extract lowers blood pressure and improves endothelial function.

    Science.gov (United States)

    Joven, Jorge; March, Isabel; Espinel, Eugenia; Fernández-Arroyo, Salvador; Rodríguez-Gallego, Esther; Aragonès, Gerard; Beltrán-Debón, Raúl; Alonso-Villaverde, Carlos; Rios, Lidia; Martin-Paredero, Vicente; Menendez, Javier A; Micol, Vicente; Segura-Carretero, Antonio; Camps, Jordi

    2014-06-01

    Polyphenols from Hibiscus sabdariffa calices were administered to patients with metabolic syndrome (125 mg/kg/day for 4 wk, n = 31) and spontaneously hypertensive rats (125 or 60 mg/kg in a single dose or daily for 1 wk, n = 8 for each experimental group). The H. sabdariffa extract improved metabolism, displayed potent anti-inflammatory and antioxidant activities, and significantly reduced blood pressure in both humans and rats. Diuresis and inhibition of the angiotensin I-converting enzyme were found to be less important mechanisms than those related to the antioxidant, anti-inflammatory, and endothelium-dependent effects to explain the beneficial actions. Notably, polyphenols induced a favorable endothelial response that should be considered in the management of metabolic cardiovascular risks. © 2014 The Authors. Molecular Nutrition & Food Research published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. 46 CFR 153.436 - Heat transfer fluids: compatibility with cargo.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Heat transfer fluids: compatibility with cargo. 153.436... Equipment Cargo Temperature Control Systems § 153.436 Heat transfer fluids: compatibility with cargo. A heat transfer fluid separated from the cargo by only one wall (for example, the heat transfer fluid in a coil...

  10. Modelling and optimization of car-to-car compatibility - Modellierung und optimierung von pkw-pkw-kompatibilität

    NARCIS (Netherlands)

    Mooi, H.G.; Nastic, T.; Huibers, J.H.A.M.

    1999-01-01

    In this paper simple and more detailed MADYMO multibody models were used to simulate the car structure for improving the car-to-car compatibility of the whole car fleet. As a first step, survey studies were performed to develop a method for the optimization of car design with respect to frontal and

  11. Compatibility of heat resistant alloys with boron carbide, 5

    International Nuclear Information System (INIS)

    Baba, Shinichi; Kurasawa, Toshimasa; Endow, Taichi; Someya, Hiroyuki; Tanaka, Isao.

    1986-08-01

    This paper includes an experimental result of out-of-pile compatibility and capsule design for irradiation test in Japan Materials Testing Reactor (JMTR). The compatibility between sheath material and neutron absorber materials for control rod devices (CRD) was examined for potential use in a very high temperature reactor (VHTR) which is under development at JAERI. The purpose of the compatibility tests are preliminary evaluation of safety prior to irradiation tests. Preliminary compatibility evaluation was concerned with three items as follows : 1) Lithium effects on the penetrating reaction of Incoloy 800H alloy in contact with a mixture of boronated graphite and lithium hydroxide powders, 2) Short term tensile properties of Incoloy 800H and Hastelloy XR alloy reacted with boronated graphite and fracture mode analysis, 3) Reaction behavior of both alloys under transient power conditions of a VHTR. It was clear that the reaction rate constant of the Incoloy 800H alloy was accelerated by doping lithium hydroxide into the boron carbide and graphite powder. The mechanical properties of Incoloy 800H and Hastelloy XR alloy reacted with boronated graphite were decreased. Ultimate tensile strength and tensile ductilities at temperatures over 850 deg C were reduced, but there was no change in the proof (yield) stress. Both alloys exhibited a brittle intergranular fracture mode during transient power conditions of a VHTR and also exhibited severe penetration. Irradiation capsules for compatibility test were designed to simulate three irradiation conditions of VHTR: 1) steady state for VHTR, 2) Transient power condition, 3) Service limited life of CRD. Capsule irradiation experiments have been carried out satisfactorily and thus confirm the validity of the capsule design procedure. (author)

  12. Synthesis of artificial spectrum-compatible seismic accelerograms

    International Nuclear Information System (INIS)

    Vrochidou, E; Alvanitopoulos, P F; Andreadis, I; Mallousi, K; Elenas, A

    2014-01-01

    The Hilbert–Huang transform is used to generate artificial seismic signals compatible with the acceleration spectra of natural seismic records. Artificial spectrum-compatible accelerograms are utilized instead of natural earthquake records for the dynamic response analysis of many critical structures such as hospitals, bridges, and power plants. The realistic estimation of the seismic response of structures involves nonlinear dynamic analysis. Moreover, it requires seismic accelerograms representative of the actual ground acceleration time histories expected at the site of interest. Unfortunately, not many actual records of different seismic intensities are available for many regions. In addition, a large number of seismic accelerograms are required to perform a series of nonlinear dynamic analyses for a reliable statistical investigation of the structural behavior under earthquake excitation. These are the main motivations for generating artificial spectrum-compatible seismic accelerograms and could be useful in earthquake engineering for dynamic analysis and design of buildings. According to the proposed method, a single natural earthquake record is deconstructed into amplitude and frequency components using the Hilbert–Huang transform. The proposed method is illustrated by studying 20 natural seismic records with different characteristics such as different frequency content, amplitude, and duration. Experimental results reveal the efficiency of the proposed method in comparison with well-established and industrial methods in the literature. (paper)

  13. Investigating Climate Compatible Development Outcomes and their Implications for Distributive Justice: Evidence from Malawi

    Science.gov (United States)

    Wood, Benjamin T.; Quinn, Claire H.; Stringer, Lindsay C.; Dougill, Andrew J.

    2017-09-01

    Governments and donors are investing in climate compatible development in order to reduce climate and development vulnerabilities. However, the rate at which climate compatible development is being operationalised has outpaced academic enquiry into the concept. Interventions aiming to achieve climate compatible development "wins" (for development, mitigation, adaptation) can also create negative side-effects. Moreover, benefits and negative side-effects may differ across time and space and have diverse consequences for individuals and groups. Assessments of the full range of outcomes created by climate compatible development projects and their implications for distributive justice are scarce. This article develops a framework using a systematic literature review that enables holistic climate compatible development outcome evaluation over seven parameters identified. Thereafter, we explore the outcomes of two donor-funded projects that pursue climate compatible development triple-wins in Malawi using this framework. Household surveys, semi-structured interviews and documentary material are analysed. Results reveal that uneven outcomes are experienced between stakeholder groups and change over time. Although climate compatible development triple-wins can be achieved through projects, they do not represent the full range of outcomes. Ecosystem—and community-based activities are becoming popularised as approaches for achieving climate compatible development goals. However, findings suggest that a strengthened evidence base is required to ensure that these approaches are able to meet climate compatible development goals and further distributive justice.

  14. Decreased cerebral blood flow after administration of sodium bicarbonate in the distressed newborn infant

    DEFF Research Database (Denmark)

    Lou, H C; Lassen, N A; Fris-Hansen, B

    1978-01-01

    In the course of our studies on cerebral blood flow in newborn infants, we have observed a striking depressing effect of sodium bicarbonate infusion on cerebral blood flow which in some cases may severely aggravate cerebral ischemia. We measured cerebral blood flow before and after the treatment...... with 1 to 8 meqs of sodium bicarbonate in seven distressed newborn infants. The 133 Xe clearance technique was used. The results showed in six of the seven cases a decrease in cerebral blood flow, which in most cases was reduced to 14 to 22 ml/100 g/min, which is about half the value prior...... to the bicarbonate infusion. In one case an extreme reduction occurred: cerebral blood flow was reduced to 3 ml/100 g/min, well below the level compatible with tissue survival. The results are discussed with regard to the optimal treatment of the acidotic newborn....

  15. High-cocoa polyphenol-rich chocolate improves blood pressure in patients with diabetes and hypertension.

    Science.gov (United States)

    Rostami, Ali; Khalili, Mohammad; Haghighat, Neda; Eghtesadi, Shahryar; Shidfar, Farzad; Heidari, Iraj; Ebrahimpour-Koujan, Soraiya; Eghtesadi, Maryam

    2015-01-01

    The aim was to examine the effects of high-cocoa polyphenol-rich chocolate on lipid profiles, weight, blood pressure, glycemic control, and inflammation in individuals with Type 2 diabetes and hypertension. Sixty individuals [32 in dark chocolate group (DCG) and 28 in white chocolate group (WCG)] with Type 2 diabetes on stable medication were enrolled in a randomized, placebo-controlled double-blind study. Subjects were randomized to consume 25 g DCG or WCG for 8 weeks. Changes in weight, blood pressure, glycemic control, lipid profile, and high sensitive C-reactive protein (hsCRP) were measured at the beginning and end of the intervention. This clinical trial was registered at the Iranian registry of clinical trials. In DCC group, compared with baseline, serum levels of Apo A-1 (P = 0.045) was increased and fasting blood sugar (FBS) (P = 0.027), hemoglobin A1c (HbA1c) (P = 0.025), Apo B (P = 0.012) and Log of hsCRP (P = 0.043) levels were decreased at the end of study. No changes were seen within the WCG in studied parameters. High polyphenol chocolate consumption compared to white chocolate resulted in significant decrease in of systolic (-5.93 ± 6.25 vs. -1.07 ± 7.97 mmHg, P = 0.004) and diastolic blood pressure (-6.4 ± 6.25 vs. 0.17 ± 7.9 mmHg, P = 0.002), FBS (-7.84 ± 19.15 vs. 4.00 ± 20.58 mg/dl, P = 0.019) over the course of 8 weeks of daily chocolate consumption neither weight nor body mass index and TG levels altered from baseline. High polyphenol chocolate is effective in improving TG levels in hypertensive patients with diabetes and decreasing blood pressure and FBS without affecting weight, inflammatory markers, insulin resistance or glycemic control.

  16. Breeding graft-compatible Douglas-fir rootstocks (Pseudotsuga menziesii (Mirb.) Franco).

    Science.gov (United States)

    D.L. Copes

    1999-01-01

    A study encompassing 24 years was conducted to determine if a breeding program could produce highly graft-compatible rootstocks. Twenty-seven trees of apparent high graft compatibility were selected and crossed to produce 226 control-pollinated families. Seedlings were grown, field planted, and grafted with test scions. Graft unions from field tests were evaluated...

  17. Application of Hilbert-Huang Transform in Generating Spectrum-Compatible Earthquake Time Histories

    OpenAIRE

    Ni, Shun-Hao; Xie, Wei-Chau; Pandey, Mahesh

    2011-01-01

    Spectrum-compatible earthquake time histories have been widely used for seismic analysis and design. In this paper, a data processing method, Hilbert-Huang transform, is applied to generate earthquake time histories compatible with the target seismic design spectra based on multiple actual earthquake records. Each actual earthquake record is decomposed into several components of time-dependent amplitude and frequency by Hilbert-Huang transform. The spectrum-compatible earthquake time history ...

  18. Central Cross-Talk in Task Switching : Evidence from Manipulating Input-Output Modality Compatibility

    Science.gov (United States)

    Stephan, Denise Nadine; Koch, Iring

    2010-01-01

    Two experiments examined the role of compatibility of input and output (I-O) modality mappings in task switching. We define I-O modality compatibility in terms of similarity of stimulus modality and modality of response-related sensory consequences. Experiment 1 included switching between 2 compatible tasks (auditory-vocal vs. visual-manual) and…

  19. Self-monitoring and self-management: new interventions to improve blood pressure control.

    Science.gov (United States)

    McCartney, David E; McManus, Richard J

    2016-11-01

    This article reviews recent developments in self-monitoring and self-management of hypertension aimed at the improvement of blood pressure (BP) control. There is an increasing body of evidence examining the effects of self-monitoring on BP control. Several landmark studies in recent years have demonstrated clinically relevant benefit from self-monitoring based interventions. Self-management of BP with self-titration has shown particular promise, as has self-monitoring combined with intensive health-care led support. There is a lack of evidence on the benefits of self-monitoring for those with important comorbidity such as coronary heart disease, chronic kidney disease, diabetes and previous stroke, and future research should be directed towards this. There is a growing body of evidence supporting the use of self-monitoring along with additional intervention including telemonitoring and self-titration in improving BP control. Further research is needed to understand which patients are likely to benefit most and how this is best integrated with routine care.

  20. Energetic materials standards – Chemical compatibility

    NARCIS (Netherlands)

    Tuukkanen, I.M.; Bouma, R.H.B.

    2014-01-01

    Subgroup A Energetic Materials Team, SG/A (EMT), develops and maintains standards that are relevant to all life-cycle phases of ammunition/weapon systems. STANAG 4147 is the standard regarding chemical compatibility of explosives with munition components, and is a document of prime importance.

  1. Cost-Effective Cementitious Material Compatible with Yucca Mountain Repository Geochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Dole, LR

    2004-12-17

    The current plans for the Yucca Mountain (YM) repository project (YMP) use steel structures to stabilize the disposal drifts and connecting tunnels that are collectively over 100 kilometers in length. The potential exist to reduce the underground construction cost by 100s of millions of dollars and improve the repository's performance. These economic and engineering goals can be achieved by using the appropriate cementitious materials to build out these tunnels. This report describes the required properties of YM compatible cements and reviews the literature that proves the efficacy of this approach. This report also describes a comprehensive program to develop and test materials for a suite of underground construction technologies.

  2. Quality indicators for discarding blood in the National Blood Center, Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Mohammed Morish

    2012-01-01

    Full Text Available Background and Objective: The implementation of quality system and continuous evaluation of all activities of the Blood Transfusion Services (BTS can help to achieve the maximum quantity and quality of safe blood. Optimizing blood collection and processing would reduce the rate of discard and improve the efficiency of the BTS. The objective of this study is to determine the rate of discard of blood and blood component and identify its reasons at the National Blood Centre (NBC, Kuala Lumpur, during the year of 2007 in order to introduce appropriate intervention. Study Designs and Methods: Data on the number of discarded whole blood units and its components, reasons for discard, and the number of blood components processed as well as the number of collected blood units were obtained from the Blood Bank Information System - NBC database. These were analyzed. Results: The total number of blood units collected in 2007 was 171169 from which 390636 units of components were prepared. The total number of discarded whole blood units and its components was 8968 (2.3%. Platelet concentrate recorded the highest of discard at 6% (3909 followed by whole blood at 3.7% (647, fresh frozen plasma (FFP at 2.5% (2839, and cryoprecipitate at 2% (620. The rate of discarded packed red blood cells RBCs, plasma aphaeresis, and PLT aphaeresis was less than 1% at 0.6% (902, 0.6% (37, and 0.29% (14, respectively. RBC contamination of PLT and plasma were the major cause of discard at 40% (3558. Other causes include leakage (26% - 2306, lipemia (25% - 2208, and underweight (4% - 353. Conclusion: Good donor selection, training and evaluation of the staff, as well as implementation of automation will help to improve processes and output of BTS. This would reduce discard of blood components and wastage caused by non conformance.

  3. Biochemical mechanisms determine the functional compatibility of heterologous genes

    DEFF Research Database (Denmark)

    Porse, Andreas; Schou, Thea S.; Munck, Christian

    2018-01-01

    -gene libraries have suggested that sequence composition is a strong barrier for the successful integration of heterologous genes. Here we sample 200 diverse genes, representing >80% of sequenced antibiotic resistance genes, to interrogate the factors governing genetic compatibility in new hosts. In contrast...... factors governing the functionality and fitness of antibiotic resistance genes. These findings emphasize the importance of biochemical mechanism for heterologous gene compatibility, and suggest physiological constraints as a pivotal feature orienting the evolution of antibiotic resistance....

  4. Renal embolic protection devices improve blood flow after stenting for atherosclerotic renal artery stenosis.

    Science.gov (United States)

    Paul, Timir K; Lee, John H; White, Christopher J

    2012-11-15

    We sought to measure angiographic renal frame counts (RFC), as a quantitative angiographic assessment of renal blood flow, to evaluate microvascular compromise due to atheroembolism associated with RAS. Atheroembolism associated with renal artery stenting (RAS) has been implicated as a cause for worsening renal function following successful intervention. Use of a distal embolic protection device (EPD) during RAS has been shown to be safe with debris capture in a high percentage of cases. However, objective benefit for renal function with EPD has been difficult to demonstrate. A control group of 30 consecutive patients (33 kidneys) who underwent RAS without EPD were compared with 33 consecutive patients (33 kidneys) who underwent RAS with EPD using RFC measurement. The prestent and poststent mean RFC for the control group was 30.4 ± 12.1 vs. 23.7 ± 9.9 (P = 0.002) and for the EPD group it was 42.6 ± 12.6 vs. 28.3 ± 9.2 (P renal blood flow, manifested by a greater reduction of the RFC (Δ RFC) 14.2 ± 15.2 vs. 6.7 ± 11.7 (P = 0.03) compared with the control group. The use of an EPD was associated with a much larger improvement in renal blood flow (lower RFC) following RAS. This suggests that EPD's may be effective in preventing renal atheroembolic injury and that a controlled trial measuring the impact of EPD's on renal blood flow following RAS should be performed. Copyright © 2012 Wiley Periodicals, Inc.

  5. Development of blood extraction system for health monitoring system

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2004-03-01

    The purpose of this research is to develop the compact human blood sampling device applied for a health monitoring system(HMS), which is called "Mobile Hospital". The HMS consists of (1) a micro electrical pumping system for blood extraction, (2) a bio-sensor to detect and evaluate an amount of Glucose, Cholesterol and Urea in extracted blood, by using enzyme such as Glucoseoxidase (GOD), Cholesteroloxidase and Urease. The mechanical design elements of the device are bio-compatible microneedle, indentation unit using a shape memory alloy(SMA) actuator and pumping unit using a piezoelectric microactuator. The design concept is the biomimetic micromachine of female mosquito"s blood sampling mechanism. The performances of the main mechanical elements such as indentation force of the microneedle, actual stroke of the indentation unit using a SMA actuator and liquid sampling ability of the pumping unit using PZT piezoelectric microactuator were measured. The 3 mm stroke of the indentation load generated by SMA actuator was 0.8mN. The amount of imitation blood extracted by using bimorph PZT actuators was about 0.5 microliters for 10 sec. A 60-micrometer outer diameter and 25-micrometer inner diameter Titanium microneedle, which size is same as female mosquito"s labium, was produced by sputter deposition.

  6. A randomized trail using motivational interviewing for maintenance of blood pressure improvements in a community-engaged lifestyle intervention: HUB City Steps

    Science.gov (United States)

    Background: Little is known about the effective dose of motivational interviewing for maintaining intervention-induced health outcome improvements. Purpose: To compare effects of two doses of motivational interviewing for maintaining blood pressure improvements in a community-engaged lifestyle int...

  7. Backward compatibility as a key measure for smooth upgrades to the LHC control system

    International Nuclear Information System (INIS)

    Baggiolini, V.; Csikos, D.; Tarasenko, P.; Zaharieva, Z.; Arruat, M.; Gorbosonov, R.

    2012-01-01

    It is a big challenge to smoothly upgrade the control system of a large operational accelerator such as the LHC without causing unnecessary downtime. We have identified backward compatibility as a key measure to achieve this, because a backward compatible component can be easily upgraded. This document describes the work the CERN Accelerator Controls group does to provide methods and tools supporting backward compatibility. We have identified four areas for which we want to provide tools: (1) dependency analysis to identify incoming dependencies, (2) backward compatibility validation to verify that API (Application Program Interface) changes are really backward compatible, (3) version upgrading with rules to clearly inform the dependent clients if a modification is backward compatible, and (4) API consolidation to clearly specify classes and methods belonging to the API and to enforce their appropriate usage

  8. Neighboring block based disparity vector derivation for multiview compatible 3D-AVC

    Science.gov (United States)

    Kang, Jewon; Chen, Ying; Zhang, Li; Zhao, Xin; Karczewicz, Marta

    2013-09-01

    3D-AVC being developed under Joint Collaborative Team on 3D Video Coding (JCT-3V) significantly outperforms the Multiview Video Coding plus Depth (MVC+D) which simultaneously encodes texture views and depth views with the multiview extension of H.264/AVC (MVC). However, when the 3D-AVC is configured to support multiview compatibility in which texture views are decoded without depth information, the coding performance becomes significantly degraded. The reason is that advanced coding tools incorporated into the 3D-AVC do not perform well due to the lack of a disparity vector converted from the depth information. In this paper, we propose a disparity vector derivation method utilizing only the information of texture views. Motion information of neighboring blocks is used to determine a disparity vector for a macroblock, so that the derived disparity vector is efficiently used for the coding tools in 3D-AVC. The proposed method significantly improves a coding gain of the 3D-AVC in the multiview compatible mode about 20% BD-rate saving in the coded views and 26% BD-rate saving in the synthesized views on average.

  9. Magnetic resonance imaging-compatible tactile sensing device based on a piezoelectric array.

    Science.gov (United States)

    Hamed, Abbi; Masamune, Ken; Tse, Zion Tsz Ho; Lamperth, Michael; Dohi, Takeyoshi

    2012-07-01

    Minimally invasive surgery is a widely used medical technique, one of the drawbacks of which is the loss of direct sense of touch during the operation. Palpation is the use of fingertips to explore and make fast assessments of tissue morphology. Although technologies are developed to equip minimally invasive surgery tools with haptic feedback capabilities, the majority focus on tissue stiffness profiling and tool-tissue interaction force measurement. For greatly increased diagnostic capability, a magnetic resonance imaging-compatible tactile sensor design is proposed, which allows minimally invasive surgery to be performed under image guidance, combining the strong capability of magnetic resonance imaging soft tissue and intuitive palpation. The sensing unit is based on a piezoelectric sensor methodology, which conforms to the stringent mechanical and electrical design requirements imposed by the magnetic resonance environment The sensor mechanical design and the device integration to a 0.2 Tesla open magnetic resonance imaging scanner are described, together with the device's magnetic resonance compatibility testing. Its design limitations and potential future improvements are also discussed. A tactile sensing unit based on a piezoelectric sensor principle is proposed, which is designed for magnetic resonance imaging guided interventions.

  10. An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

    Science.gov (United States)

    Yamazaki, K; Litwak, P; Tagusari, O; Mori, T; Kono, K; Kameneva, M; Watach, M; Gordon, L; Miyagishima, M; Tomioka, J; Umezu, M; Outa, E; Antaki, J F; Kormos, R L; Koyanagi, H; Griffith, B P

    1998-06-01

    A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).

  11. Team-Based Care with Pharmacists to Improve Blood Pressure: a Review of Recent Literature.

    Science.gov (United States)

    Kennelty, Korey A; Polgreen, Linnea A; Carter, Barry L

    2018-01-18

    We review studies published since 2014 that examined team-based care strategies and involved pharmacists to improve blood pressure (BP). We then discuss opportunities and challenges to sustainment of team-based care models in primary care clinics. Multiple studies presented in this review have demonstrated that team-based care including pharmacists can improve BP management. Studies highlighted the cost-effectiveness of a team-based pharmacy intervention for BP control in primary care clinics. Little information was found on factors influencing sustainability of team-based care interventions to improve BP control. Future work is needed to determine the best populations to target with team-based BP programs and how to implement team-based approaches utilizing pharmacists in diverse clinical settings. Future studies need to not only identify unmet clinical needs but also address reimbursement issues and stakeholder engagement that may impact sustainment of team-based care interventions.

  12. Compatibility of niobium, titanium, and vanadium metals with LMFBR cladding

    International Nuclear Information System (INIS)

    Wilson, C.N.

    1975-10-01

    A series of laboratory capsule annealing experiments were conducted to assess the compatibility of niobium, vanadium, and titanium with 316 stainless steel cladding in the temperature range of 700 to 800 0 C. Niobium, vanadium, and titanium are cantidate oxygen absorber materials for control of oxygen chemistry in LMFBR fuel pins. Capsule examination indicated good compatibility between niobium and 316 stainless steel at 800 0 C. Potential compatibility problems between cladding and vanadium or titanium were indicated at 800 0 C under reducing conditions. In the presence of Pu/sub 0.25/U/sub 0.75/O/sub 1.98/ fuel (Δanti G 02 congruent to -160 kcal/mole) no reaction was observed between vanadium or titanium and cladding at 800 0 C

  13. Compatibility of Motion Facilitates Visuomotor Synchronization

    Science.gov (United States)

    Hove, Michael J.; Spivey, Michael J.; Krumhansl, Carol L.

    2010-01-01

    Prior research indicates that synchronized tapping performance is very poor with flashing visual stimuli compared with auditory stimuli. Three finger-tapping experiments compared flashing visual metronomes with visual metronomes containing a spatial component, either compatible, incompatible, or orthogonal to the tapping action. In Experiment 1,…

  14. Improved arterial blood oxygenation following intravenous infusion of cold supersaturated dissolved oxygen solution.

    Science.gov (United States)

    Grady, Daniel J; Gentile, Michael A; Riggs, John H; Cheifetz, Ira M

    2014-01-01

    One of the primary goals of critical care medicine is to support adequate gas exchange without iatrogenic sequelae. An emerging method of delivering supplemental oxygen is intravenously rather than via the traditional inhalation route. The objective of this study was to evaluate the gas-exchange effects of infusing cold intravenous (IV) fluids containing very high partial pressures of dissolved oxygen (>760 mm Hg) in a porcine model. Juvenile swines were anesthetized and mechanically ventilated. Each animal received an infusion of cold (13 °C) Ringer's lactate solution (30 mL/kg/hour), which had been supersaturated with dissolved oxygen gas (39.7 mg/L dissolved oxygen, 992 mm Hg, 30.5 mL/L). Arterial blood gases and physiologic measurements were repeated at 15-minute intervals during a 60-minute IV infusion of the supersaturated dissolved oxygen solution. Each animal served as its own control. Five swines (12.9 ± 0.9 kg) were studied. Following the 60-minute infusion, there were significant increases in PaO2 and SaO2 (P < 0.05) and a significant decrease in PaCO2 (P < 0.05), with a corresponding normalization in arterial blood pH. Additionally, there was a significant decrease in core body temperature (P < 0.05) when compared to the baseline preinfusion state. A cold, supersaturated dissolved oxygen solution may be intravenously administered to improve arterial blood oxygenation and ventilation parameters and induce a mild therapeutic hypothermia in a porcine model.

  15. A JPEG backward-compatible HDR image compression

    Science.gov (United States)

    Korshunov, Pavel; Ebrahimi, Touradj

    2012-10-01

    High Dynamic Range (HDR) imaging is expected to become one of the technologies that could shape next generation of consumer digital photography. Manufacturers are rolling out cameras and displays capable of capturing and rendering HDR images. The popularity and full public adoption of HDR content is however hindered by the lack of standards in evaluation of quality, file formats, and compression, as well as large legacy base of Low Dynamic Range (LDR) displays that are unable to render HDR. To facilitate wide spread of HDR usage, the backward compatibility of HDR technology with commonly used legacy image storage, rendering, and compression is necessary. Although many tone-mapping algorithms were developed for generating viewable LDR images from HDR content, there is no consensus on which algorithm to use and under which conditions. This paper, via a series of subjective evaluations, demonstrates the dependency of perceived quality of the tone-mapped LDR images on environmental parameters and image content. Based on the results of subjective tests, it proposes to extend JPEG file format, as the most popular image format, in a backward compatible manner to also deal with HDR pictures. To this end, the paper provides an architecture to achieve such backward compatibility with JPEG and demonstrates efficiency of a simple implementation of this framework when compared to the state of the art HDR image compression.

  16. Non-invasive, MRI-compatible fibreoptic device for functional near-IR reflectometry of human brain

    International Nuclear Information System (INIS)

    Sorvoja, H.S.S.; Myllylae, T S; Myllylae, Risto A; Kirillin, M Yu; Sergeeva, Ekaterina A; Elseoud, A A; Nikkinen, J; Tervonen, O; Kiviniemi, V

    2011-01-01

    A non-invasive device for measuring blood oxygen variations in human brain is designed, implemented, and tested for MRI compatibility. The device is based on principles of near-IR reflectometry; power LEDs serve as sources of probing radiation delivered to patient skin surface through optical fibres. Numerical Monte Carlo simulations of probing radiation propagation in a multilayer brain model are performed to evaluate signal levels at different source - detector separations at three operation wavelengths and an additional wavelength of 915 nm. It is shown that the device can be applied for brain activity studies using power LEDs operating at 830 and 915 nm, while employment of wavelength of 660 nm requires an increased probing power. Employment of the wavelength of 592 nm in the current configuration is unreasonable. (application of lasers and laser-optical methods in life sciences)

  17. Half a decade of mini-pool nucleic acid testing: Cost-effective way for improving blood safety in India

    Directory of Open Access Journals (Sweden)

    Shivaram Chandrashekar

    2014-01-01

    Full Text Available Background and Objectives: It is well established that Nucleic acid testing (NAT reduces window phase of transfusion transmissible infections (TTI and helps improve blood safety. NAT testing can be done individually or in pools. The objectives of this study were to determine the utility, feasibility and cost effectiveness of an in-house minipool-NAT(MP-NAT. Materials and Methods: Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR. Testing was done in mini-pools of size eight (8. Positive pools were repeated with individual samples. Results: During the study period of Oct 2005-Sept 2010 (5 years all blood donors (n=53729 were screened by ELISA. Of which 469 (0.87% were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260 were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1 and HBV NAT yield (n=2 was 1/26630. Conclusion: NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment.

  18. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  19. The Volpe Center GPS Adjacent Band Compatibility Program Plan : GPS Adjacent Band Compatibility Workshop, Volpe Center, Cambridge MA

    Science.gov (United States)

    2014-09-18

    Approach to DOT GPS Adjacent Band Compatibility Assessment. Identify forums and provide public outreach to make sure the progress and work are as open and transparent as possible. Develop an implementation plan that incorporates aspects from the DOT ...

  20. Associations of ambulatory blood pressure with urinary caffeine and caffeine metabolite excretions.

    Science.gov (United States)

    Guessous, Idris; Pruijm, Menno; Ponte, Belén; Ackermann, Daniel; Ehret, Georg; Ansermot, Nicolas; Vuistiner, Philippe; Staessen, Jan; Gu, Yumei; Paccaud, Fred; Mohaupt, Markus; Vogt, Bruno; Pechère-Bertschi, Antoinette; Pechère-Berstchi, Antoinette; Martin, Pierre-Yves; Burnier, Michel; Eap, Chin B; Bochud, Murielle

    2015-03-01

    Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure. © 2014 American Heart Association, Inc.

  1. Stiffness compatibility of coralline hydroxyapatite bone substitute under dynamic loading

    Institute of Scientific and Technical Information of China (English)

    REN ChaoFeng; HOU ZhenDe; ZHAO Wei

    2009-01-01

    When hydroxyapatite bone substitutes are implanted in human bodies, bone tissues will grow into their porous structure, which will reinforce their strength and stiffness. The concept of mechanical com-patibility of bone substitutes implies that their mechanical properties are similar to the bone tissues around, as if they were part of the bone. The mechanical compatibility of bone substitutes includes both static and dynamic behavior, due to the mechanical properties of bone depending on the strain rate. In this study, split Hopkinson pressure bar technique (SHPB) was employed to determine the dy-namic mechanical properties of coralline hydroxyapatite, bones with and bones without organic com-ponents, and their dynamic stress-strain curves of the three materials were obtained. The mechanical effects of collagens in bone were assessed, by comparing the difference between the Young's moduli of the three materials. As the implanted bone substitute becomes a part of bone, it can be regarded as an inclusion composite. The effective modulus of the composite was also evaluated in order to estimate its mechanical compatibility on stiffness. The evaluated result shows that the suitable porosity of HA is0.8, which is in favor of both static and dynamic stiffness compatibility.

  2. Salvianolic Acids Attenuate Rat Hippocampal Injury after Acute CO Poisoning by Improving Blood Flow Properties

    Directory of Open Access Journals (Sweden)

    Li Guan

    2015-01-01

    Full Text Available Carbon monoxide (CO poisoning causes the major injury and death due to poisoning worldwide. The most severe damage via CO poisoning is brain injury and mortality. Delayed encephalopathy after acute CO poisoning (DEACMP occurs in forty percent of the survivors of acute CO exposure. But the pathological cause for DEACMP is not well understood. And the corresponding therapy is not well developed. In order to investigate the effects of salvianolic acid (SA on brain injury caused by CO exposure from the view point of hemorheology, we employed a rat model and studied the dynamic of blood changes in the hemorheological and coagulative properties over acute CO exposure. Compared with the groups of CO and 20% mannitol + CO treatments, the severe hippocampal injury caused by acute CO exposure was prevented by SA treatment. These protective effects were associated with the retaining level of hematocrit (Hct, plasma viscosity, fibrinogen, whole blood viscosities and malondialdehyde (MDA levels in red blood cells (RBCs. These results indicated that SA treatment could significantly improve the deformation of erythrocytes and prevent the damage caused by CO poisoning. Meanwhile, hemorheological indexes are good indicators for monitoring the pathological dynamic after acute CO poisoning.

  3. Mating compatibility in the parasitic protist Trypanosoma brucei.

    Science.gov (United States)

    Peacock, Lori; Ferris, Vanessa; Bailey, Mick; Gibson, Wendy

    2014-02-21

    Genetic exchange has been described in several kinetoplastid parasites, but the most well-studied mating system is that of Trypanosoma brucei, the causative organism of African sleeping sickness. Sexual reproduction takes place in the salivary glands (SG) of the tsetse vector and involves meiosis and production of haploid gametes. Few genetic crosses have been carried out to date and consequently there is little information about the mating compatibility of different trypanosomes. In other single-celled eukaryotes, mating compatibility is typically determined by a system of two or more mating types (MT). Here we investigated the MT system in T. brucei. We analysed a large series of F1, F2 and back crosses by pairwise co-transmission of red and green fluorescent cloned cell lines through experimental tsetse flies. To analyse each cross, trypanosomes were cloned from fly SG containing a mixture of both parents, and genotyped by microsatellites and molecular karyotype. To investigate mating compatibility at the level of individual cells, we directly observed the behaviour of SG-derived gametes in intra- or interclonal mixtures of red and green fluorescent trypanosomes ex vivo. Hybrid progeny were found in all F1 and F2 crosses and most of the back crosses. The success of individual crosses was highly variable as judged by the number of hybrid clones produced, suggesting a range of mating compatibilities among F1 progeny. As well as hybrids, large numbers of recombinant genotypes resulting from intraclonal mating (selfers) were found in some crosses. In ex vivo mixtures, red and green fluorescent trypanosome gametes were observed to pair up and interact via their flagella in both inter- and intraclonal combinations. While yellow hybrid trypanosomes were frequently observed in interclonal mixtures, such evidence of cytoplasmic exchange was rare in the intraclonal mixtures. The outcomes of individual crosses, particularly back crosses, were variable in numbers of both

  4. A low-cost MRI compatible keyboard

    DEFF Research Database (Denmark)

    Jensen, Martin Snejbjerg; Heggli, Ole Adrian; Alves da Mota, Patricia

    2017-01-01

    , presenting a challenging environment for playing an instrument. Here, we present an MRI-compatible polyphonic keyboard with a materials cost of 850 $, designed and tested for safe use in 3T (three Tesla) MRI-scanners. We describe design considerations, and prior work in the field. In addition, we provide...

  5. Kidney Rehabilitation Technology by Improving Blood Flow and Nerve Activation

    International Nuclear Information System (INIS)

    Mohd Jamil Hashim

    2016-01-01

    The rehabilitation of kidney is impossible from doctors point of view. Kidney failure happens when nephron in kidney fail to filter blood and water. Two major causes of kidney failure. First is the shrinkage of kidney and the second is the blockage of kidney medulla. Kidney shrinkage is because nephron damage due to long term diabetes (Nephrology expert point of view). Whereas blockage of kidney is due to food consume which in turn build up deposit at the blood duct connecting to the medulla. Experiment specimen own body. The rehabilitation methodology is to build up your blood flow system and nerve activation. Result from the study is through analyzing blood components such as creatinine, hemoglobin, urea and potassium. Conclusion, creatinine value has lowered and kidney shrinkage has normalize to its original size. It is hopeful I regain my health 100 % when my GFR reading achieved below 100. (author)

  6. A novel multi-level IC-compatible surface microfabrication technology for MEMS with independently controlled lateral and vertical submicron transduction gaps

    Science.gov (United States)

    Cicek, Paul-Vahe; Elsayed, Mohannad; Nabki, Frederic; El-Gamal, Mourad

    2017-11-01

    An above-IC compatible multi-level MEMS surface microfabrication technology based on a silicon carbide structural layer is presented. The fabrication process flow provides optimal electrostatic transduction by allowing the creation of independently controlled submicron vertical and lateral gaps without the need for high resolution lithography. Adopting silicon carbide as the structural material, the technology ensures material, chemical and thermal compatibility with modern semiconductor nodes, reporting the lowest peak processing temperature (i.e. 200 °C) of all comparable works. This makes this process ideally suited for integrating capacitive-based MEMS directly above standard CMOS substrates. Process flow design and optimization are presented in the context of bulk-mode disk resonators, devices that are shown to exhibit improved performance with respect to previous generation flexural beam resonators, and that represent relatively complex MEMS structures. The impact of impending improvements to the fabrication technology is discussed.

  7. A novel multi-level IC-compatible surface microfabrication technology for MEMS with independently controlled lateral and vertical submicron transduction gaps

    International Nuclear Information System (INIS)

    Cicek, Paul-Vahe; Elsayed, Mohannad; Nabki, Frederic; El-Gamal, Mourad

    2017-01-01

    An above-IC compatible multi-level MEMS surface microfabrication technology based on a silicon carbide structural layer is presented. The fabrication process flow provides optimal electrostatic transduction by allowing the creation of independently controlled submicron vertical and lateral gaps without the need for high resolution lithography. Adopting silicon carbide as the structural material, the technology ensures material, chemical and thermal compatibility with modern semiconductor nodes, reporting the lowest peak processing temperature (i.e. 200 °C) of all comparable works. This makes this process ideally suited for integrating capacitive-based MEMS directly above standard CMOS substrates. Process flow design and optimization are presented in the context of bulk-mode disk resonators, devices that are shown to exhibit improved performance with respect to previous generation flexural beam resonators, and that represent relatively complex MEMS structures. The impact of impending improvements to the fabrication technology is discussed. (paper)

  8. Automation of electromagnetic compatability (EMC) test facilities

    Science.gov (United States)

    Harrison, C. A.

    1986-01-01

    Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

  9. The Effectivity of Green Coconut Water To Reduce Mercury Level In The Blood And To Improve Blood Profiles And Liver Cells Appearance (Study In Sprague Dawley Rats)

    Science.gov (United States)

    Abdulrzag, Ehmeeda M.; Nur Kristina, Tri; Suwondo, Ari; Sunoko, Henna Rya

    2018-02-01

    When people are exposed to mercury chloride, it can produce a variety of health effects in the blood and liver. Coconut water contains Zn, Fe, Vit. C, Vit B11, Vit. B6, and Se to reduce mercury chloride level in the blood and improve blood profile and liver cells. Aim of this study was to analysis the effect of green coconut water supplementation in overcoming the toxic effect of Hg chlorid in the blood and liver of Sprague dawley rats exposed to Hg chloride. Samples were randomly about 36 animals rats exposed to HgCl2 through forced feeding by 20 mg/kgBW sondage per day for 14 days, which divided into control group, and intervention groups were given fresh green coconut water in each by 6, 8, and 10 mL/kgBW for intervention 7 and 17 days. The result of this study showed that there is a significant effect and the decrease in mercury levels in the blood. There is no significant affect on the hemoglobin level, hematocrit level and platelet count with the treatment of green coconut water in the mice with exposure Hg. There is no significant effect between treatments using green coconut water with SGPT levels; there is a decrease in SGPT levels at the increasing number of doses of green coconut water and the length of treatment.

  10. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  11. Towards water compatible MIPs for sensing in aqueous media.

    Science.gov (United States)

    Horemans, F; Weustenraed, A; Spivak, D; Cleij, T J

    2012-06-01

    When synthesizing molecularly imprinted polymers (MIPs), a few fundamental principles should be kept in mind. There is a strong correlation between porogen polarity, MIP microenvironment polarity and the imprinting effect itself. The combination of these parameters eventually determines the overall binding behavior of a MIP in a given solvent. In addition, it is shown that MIP binding is strongly influenced by the polarity of the rebinding solvent. Because the use of MIPs in biomedical environments is of considerable interest, it is important that these MIPs perform well in aqueous media. In this article, various approaches are explored towards a water compatible MIP for the target molecule l-nicotine. To this end, the imprinting effect together with the MIP matrix polarity is fine-tuned during MIP synthesis. The binding behavior of the resulting MIPs is evaluated by performing batch rebinding experiments that makes it possible to select the most suitable MIP/non-imprinted polymer couple for future application in aqueous environments. One method to achieve improved compatibility with water is referred to as porogen tuning, in which porogens of varying polarities are used. It is demonstrated that, especially when multiple porogens are mixed, this approach can lead to superior performance in aqueous environments. Another method involves the incorporation of polar or non-polar comonomers in the MIP matrix. It is shown that by carefully selecting these monomers, it is also possible to obtain MIPs, which can selectively bind their target in water. Copyright © 2012 John Wiley & Sons, Ltd.

  12. Stem cells of umbilical blood cord – therapeutic use

    Directory of Open Access Journals (Sweden)

    Beata Bielec

    2015-07-01

    Full Text Available For many years, the transplantation of hematopoietic stem cells has been used to treat some diseases of the hematopoietic system. For a very long time, only bone marrow was used as a source of hematopoietic stem cells for this method of treatment. However, to comply with allogeneic bone marrow transplantation, an antigenically compatible donor is necessary. Transplantations from unrelated donors are associated with increased risk of a graft-versus-host reaction, transplant rejection and, consequently, increased mortality. Many years ago, it was found that umbilical cord blood as well as bone marrow and peripheral blood contains hematopoietic stem cells and mesenchymal cells able to differentiate into different cell types and that the umbilical cord blood can be a source of stem cells for transplantation. Following this discovery, numerous attempts were made for its potential use in the treatment of hematologic diseases, metabolic diseases as well as regenerative medicine. Umbilical cord blood stem cells exhibit intermediate characteristics between embryonic and adult stem cells. They are distinguished from the latter by telomere length, telomerase activity, and lower risk of accumulation of DNA mutations or chromosomal aberrations. The only transplantation limitation appears to be the amount of cord blood collected, which on average is sufficient for transplantation in a 40-50 kg child. Collection of cord blood is a simple, short-lasting treatment, not causing any danger for a newborn or the mother. Umbilical cord blood is obtained during labor, and then frozen and stored at cord blood banks all over the world.

  13. Compatibility, persistence and productivity of grass-legume mixtures for sustainable animal production in the Atlantic Zone of Costa Rica

    NARCIS (Netherlands)

    Ibrahim, M.A.

    1994-01-01

    The main objective of this study was to identify compatible and persistent grass-legume mixtures of high feeding value for forage improvement in the Atlantic Zone of Costa Rica. The study was conducted between September 1989 and October 1992 at LA)s Diamantes research station, Guápiles,

  14. Compatibility grab sampling and analysis plan for fiscal year 1999

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    1999-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for grab samples obtained to address waste compatibility. Analytical requirements are taken from two revisions of the Compatibility data quality objectives (DQOs). Revision 1 of the DQO (Fowler 1995) listed analyses to be performed to meet both safety and operational data needs for the Compatibility program. Revision 2A of the DQO (Mulkey and Miller 1998) addresses only the safety-related requirements; the operational requirements of Fowler (1995) have not been superseded by Mulkey and Miller (1998). Therefore, safety-related data needs are taken from Mulkey and Miller (1998) and operational-related data needs are taken from Fowler (1995). Ammonia and total alpha analyses are also performed in accordance with Fowler (1998a, 1998b)

  15. Elements of a compatible optimization theory for coupled systems

    International Nuclear Information System (INIS)

    Bonnemay, A.

    1969-01-01

    The first theory deals with the compatible optimization in coupled systems. A game theory for two players and with a non-zero sum is first developed. The conclusions are then extended to the case of a game with any finite number of players. After this essentially static study, the dynamic aspect of the problem is applied to the case of games which evolve. By applying PONTRYAGIN maximum principle it is possible to derive a compatible optimisation theorem which constitutes a necessary condition. (author) [fr

  16. Achieving the same for less: improving mood depletes blood glucose for people with poor (but not good) emotion control.

    Science.gov (United States)

    Niven, Karen; Totterdell, Peter; Miles, Eleanor; Webb, Thomas L; Sheeran, Paschal

    2013-01-01

    Previous studies have found that acts of self-control like emotion regulation deplete blood glucose levels. The present experiment investigated the hypothesis that the extent to which people's blood glucose levels decline during emotion regulation attempts is influenced by whether they believe themselves to be good or poor at emotion control. We found that although good and poor emotion regulators were equally able to achieve positive and negative moods, the blood glucose of poor emotion regulators was reduced after performing an affect-improving task, whereas the blood glucose of good emotion regulators remained unchanged. As evidence suggests that glucose is a limited energy resource upon which self-control relies, the implication is that good emotion regulators are able to achieve the same positive mood with less cost to their self-regulatory resource. Thus, depletion may not be an inevitable consequence of engaging in emotion regulation.

  17. Are Naturalism and Moral Realism Compatible?

    NARCIS (Netherlands)

    Peels, H.D.

    2014-01-01

    In a recent paper, Alvin Plantinga has argued that there is good reason to think that naturalism and moral realism are incompatible. He has done so by arguing that the most important argument for the compatibility of these two theses, which has been provided by Frank Jackson, fails and that any

  18. A Randomized Trial Using Motivational Interviewing for Maintenance of Blood Pressure Improvements in a Community-Engaged Lifestyle Intervention: HUB City Steps

    Science.gov (United States)

    Landry, Alicia; Madson, Michael; Thomson, Jessica; Zoellner, Jamie; Connell, Carol; Yadrick, Kathleen

    2015-01-01

    Little is known about the effective dose of motivational interviewing for maintaining intervention-induced health outcome improvements. The purpose of this study was to compare effects of two doses of motivational interviewing for maintaining blood pressure improvements in a community-engaged lifestyle intervention conducted with…

  19. From human monocytes to genome-wide binding sites--a protocol for small amounts of blood: monocyte isolation/ChIP-protocol/library amplification/genome wide computational data analysis.

    Directory of Open Access Journals (Sweden)

    Sebastian Weiterer

    Full Text Available Chromatin immunoprecipitation in combination with a genome-wide analysis via high-throughput sequencing is the state of the art method to gain genome-wide representation of histone modification or transcription factor binding profiles. However, chromatin immunoprecipitation analysis in the context of human experimental samples is limited, especially in the case of blood cells. The typically extremely low yields of precipitated DNA are usually not compatible with library amplification for next generation sequencing. We developed a highly reproducible protocol to present a guideline from the first step of isolating monocytes from a blood sample to analyse the distribution of histone modifications in a genome-wide manner.The protocol describes the whole work flow from isolating monocytes from human blood samples followed by a high-sensitivity and small-scale chromatin immunoprecipitation assay with guidance for generating libraries compatible with next generation sequencing from small amounts of immunoprecipitated DNA.

  20. High-cocoa polyphenol-rich chocolate improves blood pressure in patients with diabetes and hypertension

    Directory of Open Access Journals (Sweden)

    Ali Rostami

    2015-01-01

    Full Text Available BACKGROUND: The aim was to examine the effects of high-cocoa polyphenol-rich chocolate on lipid profiles, weight, blood pressure, glycemic control, and inflammation in individuals with Type 2 diabetes and hypertension. METHODS: Sixty individuals [32 in dark chocolate group (DCG and 28 in white chocolate group (WCG] with Type 2 diabetes on stable medication were enrolled in a randomized, placebo-controlled double-blind study. Subjects were randomized to consume 25 g DCG or WCG for 8 weeks. Changes in weight, blood pressure, glycemic control, lipid profile, and high sensitive C-reactive protein (hsCRP were measured at the beginning and end of the intervention. This clinical trial was registered at the Iranian registry of clinical trials. RESULTS: In DCC group, compared with baseline, serum levels of Apo A-1 (P = 0.045 was increased and fasting blood sugar (FBS (P = 0.027, hemoglobin A1c (HbA1c (P = 0.025, Apo B (P = 0.012 and Log of hsCRP (P = 0.043 levels were decreased at the end of study. No changes were seen within the WCG in studied parameters. High polyphenol chocolate consumption compared to white chocolate resulted in significant decrease in of systolic (−5.93 ± 6.25 vs. −1.07 ± 7.97 mmHg, P = 0.004 and diastolic blood pressure (−6.4 ± 6.25 vs. 0.17 ± 7.9 mmHg, P = 0.002, FBS (−7.84 ± 19.15 vs. 4.00 ± 20.58 mg/dl, P = 0.019 over the course of 8 weeks of daily chocolate consumption neither weight nor body mass index and TG levels altered from baseline. CONCLUSION: High polyphenol chocolate is effective in improving TG levels in hypertensive patients with diabetes and decreasing blood pressure and FBS without affecting weight, inflammatory markers, insulin resistance or glycemic control.    Normal 0 false false false EN-US X-NONE FA

  1. High-cocoa polyphenol-rich chocolate improves blood pressure in patients with diabetes and hypertension

    Science.gov (United States)

    Rostami, Ali; Khalili, Mohammad; Haghighat, Neda; Eghtesadi, Shahryar; Shidfar, Farzad; Heidari, Iraj; Ebrahimpour-Koujan, Soraiya; Eghtesadi, Maryam

    2015-01-01

    BACKGROUND The aim was to examine the effects of high-cocoa polyphenol-rich chocolate on lipid profiles, weight, blood pressure, glycemic control, and inflammation in individuals with Type 2 diabetes and hypertension. METHODS Sixty individuals [32 in dark chocolate group (DCG) and 28 in white chocolate group (WCG)] with Type 2 diabetes on stable medication were enrolled in a randomized, placebo-controlled double-blind study. Subjects were randomized to consume 25 g DCG or WCG for 8 weeks. Changes in weight, blood pressure, glycemic control, lipid profile, and high sensitive C-reactive protein (hsCRP) were measured at the beginning and end of the intervention. This clinical trial was registered at the Iranian registry of clinical trials. RESULTS In DCC group, compared with baseline, serum levels of Apo A-1 (P = 0.045) was increased and fasting blood sugar (FBS) (P = 0.027), hemoglobin A1c (HbA1c) (P = 0.025), Apo B (P = 0.012) and Log of hsCRP (P = 0.043) levels were decreased at the end of study. No changes were seen within the WCG in studied parameters. High polyphenol chocolate consumption compared to white chocolate resulted in significant decrease in of systolic (−5.93 ± 6.25 vs. −1.07 ± 7.97 mmHg, P = 0.004) and diastolic blood pressure (−6.4 ± 6.25 vs. 0.17 ± 7.9 mmHg, P = 0.002), FBS (−7.84 ± 19.15 vs. 4.00 ± 20.58 mg/dl, P = 0.019) over the course of 8 weeks of daily chocolate consumption neither weight nor body mass index and TG levels altered from baseline. CONCLUSION High polyphenol chocolate is effective in improving TG levels in hypertensive patients with diabetes and decreasing blood pressure and FBS without affecting weight, inflammatory markers, insulin resistance or glycemic control. PMID:26089927

  2. Vitamin K2 Improves Anxiety and Depression but not Cognition in Rats with Metabolic Syndrome: a Role of Blood Glucose?

    Science.gov (United States)

    Gancheva, Silvia M; Zhelyazkova-Savova, Maria D

    2016-12-01

    The metabolic syndrome is a socially important disorder of energy utilization and storage, recognized as a factor predisposing to the development of depression, anxiety and cognitive impairment in humans. In the present study we examined the effects of vitamin K2 on the behavior of rats with metabolic syndrome and looked for relationships with the effects on blood sugar. Male Wistar rats were divided in four groups: a control group on a regular rat chow, a metabolic syndrome (MS) group fed a high-fat high-fructose diet, a control group treated with vitamin K2 and a MS group treated with vitamin K2. Vitamin K2 was given by gavage. At the end of the study (after 10 weeks) behavioral tests were performed and fasting blood glucose was measured. Anxiety was determined using the social interaction test and depression was assessed by the Porsolt test. Memory effects were estimated by the object recognition test. Correlations between fasting blood glucose and behavioral performance were analyzed. The rats from the MS group had elevated blood glucose. They had anxiety, depression and memory deficit. Vitamin K2 normalized blood glucose, reduced anxiety and depression, but did not improve memory. Time of social interaction (inverse index of anxiety) and memory recognition were negatively correlated with blood glucose in the untreated rats but the immobility time (measure of depression) was not. When vitamin K2-treated rats were added, the correlation of blood glucose with the time of social interaction was kept, but the one with the recognition memory was lost. It might be that the anxiolytic effect of vitamin K2 in this setting is at least partly due to its effects on blood glucose, while the anti-depressant effect is glucose-independent. The present study demonstrated that vitamin K2 prevented the development of anxiety and depression, but did not improve the memory deficit caused by the dietary manipulation in an experimental model of metabolic syndrome. It might be that

  3. Clinical and immunological aspects of pretransplant blood transfusions

    NARCIS (Netherlands)

    Waanders, Marloes Maria

    2009-01-01

    Blood transfusions can lead to immunization or tolerance in the recipient. The latter is characterized by an improved transplant outcome after pretransplant blood transfusions. First observations of improved kidney graft outcome after blood transfusion date 35 years back, however no exclusive

  4. The Effect of Image Compatibility and Escalation of Commitment on Decision Performance

    Directory of Open Access Journals (Sweden)

    Harris K. Turino

    2012-04-01

    Full Text Available This study aims at empirically examining the extent to which Image Theory, initially developed as a theoretical basis for selecting a strategy or a decision, can be a theoretical basis for predicting a decision performance in two opposite frames: positive and negative. Image compatibility are employed to operationalize such a theory and the decision under study is progress decision represented by escalation of commitment. Thus, this study also empirically examines the connection between image compatibility and escalation of commitment as well as escalation of commitment as a mediator of the relationship between image compatibility and decision performance. The research context is Indonesia Stock Exchange (IDX that suffered from crisis in the past year (negative frame yet has been recovered recently (positive frame. The respondents are 229 individual investors in IDX. They are involved in day-to-day decision making (progress decision making with regard to their investment portofolio. The results of this study show that high image compatibility tends to lead to better decision performance in both frames. However, image compatibility may only positively affect the escalation of commitment in positive frame

  5. Color record in self-monitoring of blood glucose improves glycemic control by better self-management.

    Science.gov (United States)

    Nishimura, Akiko; Harashima, Shin-ichi; Honda, Ikumi; Shimizu, Yoshiyuki; Harada, Norio; Nagashima, Kazuaki; Hamasaki, Akihiro; Hosoda, Kiminori; Inagaki, Nobuya

    2014-07-01

    Color affects emotions, feelings, and behaviors. We hypothesized that color used in self-monitoring of blood glucose (SMBG) is helpful for patients to recognize and act on their glucose levels to improve glycemic control. Here, two color-indication methods, color record (CR) and color display (CD), were independently compared for their effects on glycemic control in less frequently insulin-treated type 2 diabetes. One hundred twenty outpatients were randomly allocated to four groups with 2×2 factorial design: CR or non-CR and CD or non-CD. Blood glucose levels were recorded in red or blue pencil in the CR arm, and a red or blue indicator light on the SMBG meter was lit in the CD arm, under hyperglycemia or hypoglycemia, respectively. The primary end point was difference in glycated hemoglobin (HbA1c) reduction in 24 weeks. Secondary end points were self-management performance change and psychological state change. HbA1c levels at 24 weeks were significantly decreased in the CR arm by -0.28% but were increased by 0.03% in the non-CR arm (P=0.044). In addition, diet and exercise scores were significantly improved in the CR arm compared with the non-CR arm. The exercise score showed significant improvement in the CD arm compared with the non-CD arm but without a significant difference in HbA1c reduction. Changes in psychological states were not altered between the arms. CR has a favorable effect on self-management performance without any influence on psychological stress, resulting in improved glycemic control in type 2 diabetes patients using less frequent insulin injection. Thus, active but not passive usage of color-indication methods by patients is important in successful SMBG.

  6. Conflicting Multi-Objective Compatible Optimization Control

    OpenAIRE

    Xu, Lihong; Hu, Qingsong; Hu, Haigen; Goodman, Erik

    2010-01-01

    Based on ideas developed in addressing practical greenhouse environmental control, we propose a new multi-objective compatible control method. Several detailed algorithms are proposed to meet the requirements of different kinds of problem: 1) A two-layer MOCC framework is presented for problems with a precise model; 2) To deal with situations

  7. Preparation of refractory cermet structures for lithium compatibility testing

    Science.gov (United States)

    Heestand, R. L.; Jones, R. A.; Wright, T. R.; Kizer, D. E.

    1973-01-01

    High-purity nitride and carbide cermets were synthesized for compatability testing in liquid lithium. A process was developed for the preparation of high-purity hafnium nitride powder, which was subsequently blended with tungsten powder or tantalum nitride and tungsten powders and fabricated into 3 in diameter billets by uniaxial hot pressing. Specimens were then cut from the billets for compatability testing. Similar processing techniques were applied to produce hafnium carbide and zirconium carbide cermets for use in the testing program. All billets produced were characterized with respect to chemistry, structure, density, and strength properties.

  8. Fv-clasp: An Artificially Designed Small Antibody Fragment with Improved Production Compatibility, Stability, and Crystallizability.

    Science.gov (United States)

    Arimori, Takao; Kitago, Yu; Umitsu, Masataka; Fujii, Yuki; Asaki, Ryoko; Tamura-Kawakami, Keiko; Takagi, Junichi

    2017-10-03

    Antibody fragments are frequently used as a "crystallization chaperone" to aid structural analysis of complex macromolecules that are otherwise crystallization resistant, but conventional fragment formats have not been designed for this particular application. By fusing an anti-parallel coiled-coil structure derived from the SARAH domain of human Mst1 kinase to the variable region of an antibody, we succeeded in creating a novel chimeric antibody fragment of ∼37 kDa, termed "Fv-clasp," which exhibits excellent crystallization compatibility while maintaining the binding ability of the original IgG molecule. The "clasp" and the engineered disulfide bond at the bottom of the Fv suppressed the internal mobility of the fragment and shielded hydrophobic residues, likely contributing to the high heat stability and the crystallizability of the Fv-clasp. Finally, Fv-clasp antibodies showed superior "chaperoning" activity over conventional Fab fragments, and facilitated the structure determination of an ectodomain fragment of integrin α6β1. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Compatibility of gas turbine materials with steam cooling

    Energy Technology Data Exchange (ETDEWEB)

    Desai, V.; Tamboli, D.; Patel, Y. [Univ. of Central Florida, Orlando, FL (United States)

    1995-10-01

    Gas turbines had been traditionally used for peak load plants and remote locations as they offer advantage of low installation costs and quick start up time. Their use as a base load generator had not been feasible owing to their poor efficiency. However, with the advent of gas turbines based combined cycle plants (CCPs), continued advances in efficiency are being made. Coupled with ultra low NO{sub x} emissions, coal compatibility and higher unit output, gas turbines are now competing with conventional power plants for base load power generation. Currently, the turbines are designed with TIT of 2300{degrees}F and metal temperatures are maintained around 1700{degrees}F by using air cooling. New higher efficiency ATS turbines will have TIT as high as 2700{degrees}F. To withstand this high temperature improved materials, coatings, and advances in cooling system and design are warranted. Development of advanced materials with better capabilities specifically for land base applications are time consuming and may not be available by ATS time frame or may prove costly for the first generation ATS gas turbines. Therefore improvement in the cooling system of hot components, which can take place in a relatively shorter time frame, is important. One way to improve cooling efficiency is to use better cooling agent. Steam as an alternate cooling agent offers attractive advantages because of its higher specific heat (almost twice that of air) and lower viscosity.

  10. Wet cupping therapy improves local blood perfusion and analgesic effects in patients with nerve-root type cervical spondylosis.

    Science.gov (United States)

    Meng, Xiang-Wen; Wang, Ying; Piao, Sheng-Ai; Lv, Wen-Tao; Zhu, Cheng-Hui; Mu, Ming-Yuan; Li, Dan-Dan; Liu, Hua-Peng; Guo, Yi

    2018-01-15

    To observe wet cupping therapy (WCT) on local blood perfusion and analgesic effects in patients with nerve-root type cervical spondylosis (NT-CS). Fifty-seven NT-CS patients were randomly divided into WCT group and Jiaji acupoint-acupuncture (JA) group according a random number table. WCT group (30 cases) was treated with WCT for 10 min, and JA group (27 cases) was treated with acupuncture for 10 min. The treatment effificacies were evaluated with a Visual Analogue Scale (VAS). Blood perfusion at Dazhui (GV 14) and Jianjing (GB 21) acupoints (affected side) was observed with a laser speckle flflowmetry, and its variations before and after treatment in both groups were compared as well. In both groups, the VAS scores signifificantly decreased after the intervention (P<0.01), while the blood perfusion at the two acupoints signifificantly increased after intervention (P<0.05); however, the increasement magnitude caused by WCT was obvious compared with JA (P<0.05). WCT could improve analgesic effects in patients with NT-CS, which might be related to increasing local blood perfusion of acupunct points.

  11. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  12. Stiffness compatibility of coralline hydroxyapatite bone substitute under dynamic loading

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    When hydroxyapatite bone substitutes are implanted in human bodies,bone tissues will grow into their porous structure,which will reinforce their strength and stiffness.The concept of mechanical com-patibility of bone substitutes implies that their mechanical properties are similar to the bone tissues around,as if they were part of the bone.The mechanical compatibility of bone substitutes includes both static and dynamic behavior,due to the mechanical properties of bone depending on the strain rate.In this study,split Hopkinson pressure bar technique(SHPB) was employed to determine the dy-namic mechanical properties of coralline hydroxyapatite,bones with and bones without organic com-ponents,and their dynamic stress-strain curves of the three materials were obtained.The mechanical effects of collagens in bone were assessed,by comparing the difference between the Young’s moduli of the three materials.As the implanted bone substitute becomes a part of bone,it can be regarded as an inclusion composite.The effective modulus of the composite was also evaluated in order to estimate its mechanical compatibility on stiffness.The evaluated result shows that the suitable porosity of HA is 0.8,which is in favor of both static and dynamic stiffness compatibility.

  13. Effects of ionizing radiation on blood and blood components: A survey

    International Nuclear Information System (INIS)

    1997-04-01

    The present publication reviews, in a comprehensive manner, the relevant literature on the effects of ionizing radiation on whole blood, blood cells, and other blood components. It presents the interested reader with sufficient information and data to facilitate rational decisions in relation to the feasibility of irradiation of blood and blood products for the purposes stated above. The IAEA expects that this can promote a wider use of the technology for improving health care practice in Member States, particularly in view of the recent spread of conventional as well as ''modern'' diseases which exert immunosuppressive effects in afflicted patients, with pathological consequences. Innumerable patients could thus benefit from this application of ionizing energy. 209 refs, 1 tab

  14. Effect of Platelet-Rich Plasma (PRP versus Autologous Whole Blood on Pain and Function Improvement in Tennis Elbow: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Seyed Ahmad Raeissadat

    2014-01-01

    Full Text Available Background. Autologous whole blood and platelet-rich plasma (PRP have been both suggested to treat chronic tennis elbow. The aim of the present study was to compare the effects of PRP versus autologous whole blood local injection in chronic tennis elbow. Methods. Forty patients with tennis elbow were randomly divided into 2 groups. Group 1 was treated with a single injection of 2 mL of autologous PRP and group 2 with 2 mL of autologous blood. Tennis elbow strap, stretching, and strengthening exercises were administered for both groups during a 2-month followup. Pain and functional improvements were assessed using visual analog scale (VAS, modified Mayo Clinic performance index for the elbow, and pressure pain threshold (PPT at 0, 4, and 8 weeks. Results. All pain and functional variables including VAS, PPT, and Mayo scores improved significantly in both groups 4 weeks after injection. No statistically significant difference was noted between groups regarding pain scores in 4-week follow-up examination (P>0.05. At 8-week reevaluations, VAS and Mayo scores improved only in PRP group (P<0.05. Conclusion. PRP and autologous whole blood injections are both effective to treat chronic lateral epicondylitis. PRP might be slightly superior in 8-week followup. However, further studies are suggested to get definite conclusion.

  15. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  16. The compatibility heuristic in non-categorical hypothetical reasoning: inferences between conditionals and disjunctions.

    Science.gov (United States)

    Espino, Orlando; Byrne, Ruth M J

    2013-11-01

    A new theory explains how people make hypothetical inferences from a premise consistent with several alternatives to a conclusion consistent with several alternatives. The key proposal is that people rely on a heuristic that identifies compatible possibilities. It is tested in 7 experiments that examine inferences between conditionals and disjunctions. Participants accepted inferences between conditionals and inclusive disjunctions when a compatible possibility was immediately available, in their binary judgments that a conclusion followed or not (Experiment 1a) and ternary judgments that included it was not possible to know (Experiment 1b). The compatibility effect was amplified when compatible possibilities were more readily available, e.g., for 'A only if B' conditionals (Experiment 2). It was eliminated when compatible possibilities were not available, e.g., for 'if and only if A B' bi-conditionals and exclusive disjunctions (Experiment 3). The compatibility heuristic occurs even for inferences based on implicit negation e.g., 'A or B, therefore if C D' (Experiment 4), and between universals 'All A's are B's' and disjunctions (Experiment 5a) and universals and conditionals (Experiment 5b). The implications of the results for alternative theories of the cognitive processes underlying hypothetical deductions are discussed. Copyright © 2013. Published by Elsevier Inc.

  17. The Effects of Different Compatibilities of Qing'e Formula on Scopolamine?induced Learning and Memory Impairment in the Mouse

    Institute of Scientific and Technical Information of China (English)

    Xiao‑Ping Zheng; Fang‑Di Hu; Li Yang; Yu‑Ling Ma; Bo‑Lu Sun; Chang‑Hong Wang; Zheng‑Tao Wang

    2017-01-01

    Background: The Qing'e formula (QEF) is a well?known traditional Chinese prescription that has been clinically employed for treatment of bone disease for hundreds of years. Objective: The present study aims to observe the effects of different compatibilities of QEF on the scopolamine?induced learning and memory impairment in the mouse, and further to explore its action mechanisms and compatibility rationality. Materials and Methods: The learning and memory alterations in the mouse were evaluated using the step?down test and Morris water maze (MWM) test; the acetylcholinesterase (AChE) activity and brain?derived neurotrophic factor (BDNF) expression in the hippocampus were measured using colorimetric method or immunohistochemistry. Results: The results showed that different compatibilities of QEF significantly prolonged latency in the step?down test, shortened escape latency in the navigation test, increased the percentage of residence time, and the percentage of swimming distance in the target quadrant in the probe trial session. In addition, our results also found that different compatibilities of QEF remarkably inhibited AChE activity and increased BDNF expression in the hippocampus of mice. What's more, the group after being treated with whole recipe (QF) showed the highest level of improvement. Conclusions: These findings not only suggest that QEF may effectively ameliorate cognitive deficits through inhibiting AChE activity and increasing BDNF expression in the hippocampus but also elucidate the rationality of QEF.

  18. Gcg-XTEN: an improved glucagon capable of preventing hypoglycemia without increasing baseline blood glucose.

    Directory of Open Access Journals (Sweden)

    Nathan C Geething

    2010-04-01

    Full Text Available While the majority of current diabetes treatments focus on reducing blood glucose levels, hypoglycemia represents a significant risk associated with insulin treatment. Glucagon plays a major regulatory role in controlling hypoglycemia in vivo, but its short half-life and hyperglycemic effects prevent its therapeutic use for non-acute applications. The goal of this study was to identify a modified form of glucagon suitable for prophylactic treatment of hypoglycemia without increasing baseline blood glucose levels.Through application of the XTEN technology, we report the construction of a glucagon fusion protein with an extended exposure profile (Gcg-XTEN. The in vivo half-life of the construct was tuned to support nightly dosing through design and testing in cynomolgus monkeys. Efficacy of the construct was assessed in beagle dogs using an insulin challenge to induce hypoglycemia. Dose ranging of Gcg-XTEN in fasted beagle dogs demonstrated that the compound was biologically active with a pharmacodynamic profile consistent with the designed half-life. Prophylactic administration of 0.6 nmol/kg Gcg-XTEN to dogs conferred resistance to a hypoglycemic challenge at 6 hours post-dose without affecting baseline blood glucose levels. Consistent with the designed pharmacokinetic profile, hypoglycemia resistance was not observed at 12 hours post-dose. Importantly, the solubility and stability of the glucagon peptide were also significantly improved by fusion to XTEN.The data show that Gcg-XTEN is effective in preventing hypoglycemia without the associated hyperglycemia expected for unmodified glucagon. While the plasma clearance of this Gcg-XTEN has been optimized for overnight dosing, specifically for the treatment of nocturnal hypoglycemia, constructs with significantly longer exposure profiles are feasible. Such constructs may have multiple applications such as allowing for more aggressive insulin treatment regimens, treating hypoglycemia due to insulin

  19. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  20. A blood-result turn-around time survey to improve congenital ...

    African Journals Online (AJOL)

    The results of a turn-around time study of blood specimens for syphilis serology in antenatal clinic attenders between 19 rural clinics and their base hospital, including a follow-up survey to assess the impact of interventions, are described. The objective of the study was to detennine how long blood samples took to get.

  1. Micromorphological effect of calcium phosphate coating on compatibility of magnesium alloy with osteoblast

    Science.gov (United States)

    Hiromoto, Sachiko; Yamazaki, Tomohiko

    2017-12-01

    Octacalcium phosphate (OCP) and hydroxyapatite (HAp) coatings were developed to control the degradation speed and to improve the biocompatibility of biodegradable magnesium alloys. Osteoblast MG-63 was cultured directly on OCP- and HAp-coated Mg-3Al-1Zn (wt%, AZ31) alloy (OCP- and HAp-AZ31) to evaluate cell compatibility. Cell proliferation was remarkably improved with OCP and HAp coatings which reduced the corrosion and prevented the H2O2 generation on Mg alloy substrate. OCP-AZ31 showed sparse distribution of living cell colonies and dead cells. HAp-AZ31 showed dense and homogeneous distribution of living cells, with dead cells localized over and around corrosion pits, some of which were formed underneath the coating. These results demonstrated that cells were dead due to changes in the local environment, and it is necessary to evaluate the local biocompatibility of magnesium alloys. Cell density on HAp-AZ31 was higher than that on OCP-AZ31 although there was not a significant difference in the amount of Mg ions released in medium between OCP- and HAp-AZ31. The outer layer of OCP and HAp coatings consisted of plate-like crystal with a thickness of around 0.1 μm and rod-like crystals with a diameter of around 0.1 μm, respectively, which grew from a continuous inner layer. Osteoblasts formed focal contacts on the tips of plate-like OCP and rod-like HAp crystals, with heights of 2-5 μm. The spacing between OCP tips of 0.8-1.1 μm was wider than that between HAp tips of 0.2-0.3 μm. These results demonstrated that cell proliferation depended on the micromorphology of the coatings which governed spacing of focal contacts. Consequently, HAp coating is suitable for improving cell compatibility and bone-forming ability of the Mg alloy.

  2. An improved fabrication process for Si-detector-compatible JFETs

    International Nuclear Information System (INIS)

    Piemonte, Claudio; Dalla Betta, Gian-Franco; Boscardin, Maurizio; Gregori, Paolo; Zorzi, Nicola; Ratti, Lodovico

    2006-01-01

    We report on JFET devices fabricated on high-resistivity silicon with a radiation detector technology. The problems affecting previous versions of these devices have been thoroughly investigated and solved by developing an improved fabrication process, which allows for a sizeable enhancement in the JFET performance. In this paper, the main features of the fabrication technology are presented and selected results from the electrical and noise characterization of transistors are discussed

  3. The effect of an instant hand sanitizer on blood glucose monitoring results.

    Science.gov (United States)

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-11-01

    People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. In our study

  4. ENGINEERING SPECIALTY ASSESSMENT OF TANK WASTE COMPATIBILITY REPORTING

    International Nuclear Information System (INIS)

    KNIGHT, M.A.

    2003-01-01

    This Engineering Specialty Assessment was conducted to review the Tank Farm Waste Transfer Compatibility Program to assess whether the program meets the needs of accelerated retrieval and closure and waste feed delivery and to identify areas and methods for streamlining the program. The assessment was conducted in June 2003 and resulted in two findings and thirteen observations. The assessment results indicate that significant opportunities exist for streamlining the program by reducing the number of criteria requiring evaluation from 21 to 11, with only six of the criteria requiring evaluation for the majority of transfers. The assessment identified areas where existing criteria require strengthening to ensure that the risks of undesirable solids precipitation, from either waste mixing or waste transfer, are minimized. The assessment further identified opportunities for using existing engineering tools to simplify the calculations involved with preparation of waste compatibility assessments. The need to ensure that a revision to the waste compatibility program is prepared to align the program criteria with those that will be implemented with the DSA approval was also identified. Finally, the assessment identified that corrective actions are required to implement a tank-by-tank PCB inventory within the Best Basis Inventory and to ensure that sample data from external waste generators is entered into the TWINS database

  5. Screening for attractants compatible with entomopathogenic fungus ...

    African Journals Online (AJOL)

    RACHEL

    2016-04-27

    Apr 27, 2016 ... Several thrips attractants were screened for compatibility with Metarhizium anisopliae (Metchnikoff). Sorokin (Hypocreales: Clavicipitaceae) and a subset of these for attraction to Megalurothrips sjostedti. Trybom (Thysanoptera: Thripidae). Conidial germination and germ tube length of M. anisopliae were.

  6. Eco-Anthropic Compatibility - a Multidisciplinary Model in Urban Ecology

    Directory of Open Access Journals (Sweden)

    MARIANO L. BIANCA

    2010-01-01

    Full Text Available In this paper I propose a multidisciplinary model of urban development which goes beyond the notion of ecological sustainability, by building on the concept of eco-anthropic compatibility. First of all I will sketch the historical development of human aggregations and I will underline the difference between ancient and modern aggregations. On the basis of this analysis, I will take into consideration the notion of sustainability and its possible application to present conurbations. I will underline several limits of the notion of sustainable development and I will propose a multidisciplinary model grounded on a broader and new notion: the eco-anthropic compatibility. Using this notion, which includes the idea of sustainability, it is possible to handle, within the model, the human factors and human living conditions inside an urban aggregation. Finally, I will state that the actual urban model is decaying and therefore, sooner or later, we will have to face the end of urban civilization; for this reason we can start imagining new future ways for human aggregations on the planet based on the notion of eco-anthropic compatibility.

  7. Liquid oxygen LOX compatibility evaluations of aluminum lithium (Al-Li) alloys: Investigation of the Alcoa 2090 and MMC weldalite 049 alloys

    Science.gov (United States)

    Diwan, Ravinder M.

    1989-01-01

    The behavior of liquid oxygen (LOX) compatibility of aluminum lithium (Al-Li) alloys is investigated. Alloy systems of Alcoa 2090, vintages 1 to 3, and of Martin Marietta Corporation (MMC) Weldalite 049 were evaluated for their behavior related to the LOX compatibility employing liquid oxygen impact test conditions under ambient pressures and up to 1000 psi. The developments of these aluminum lithium alloys are of critical and significant interest because of their lower densities and higher specific strengths and improved mechanical properties at cryogenic temperatures. Of the different LOX impact tests carried out at the Marshall Space Flight Center (MSFC), it is seen that in certain test conditions at higher pressures, not all Al-Li alloys are LOX compatible. In case of any reactivity, it appears that lithium makes the material more sensitive at grain boundaries due to microstructural inhomogeneities and associated precipitate free zones (PFZ). The objectives were to identify and rationalize the microstructural mechanisms that could be relaxed to LOX compatibility behavior of the alloy system in consideration. The LOX compatibility behavior of Al-Li 2090 and Weldalite 049 is analyzed in detail using microstructural characterization techniques with light optical metallography, scanning electron microscopy (SEM), electron microprobe analysis, and surface studies using secondary ion mass spectrometry (SIMS), electron spectroscopy in chemical analysis (ESCA) and Auger electron spectroscopy (AES). Differences in the behavior of these aluminum lithium alloys are assessed and related to their chemistry, heat treatment conditions, and microstructural effects.

  8. Mixed waste chemical compatibility: A testing program for plastic packaging components

    International Nuclear Information System (INIS)

    Nigrey, P.J.

    1995-01-01

    The purpose of hazardous and radioactive materials packaging is to enable these materials to be transported without posing a threat to the health or property of the general public. To achieve this aim, regulations in the United States have been written establishing general design requirements for such packagings. While no regulations have been written specifically for mixed waste packaging, regulations for the constituents of mixed wastes, i.e., hazardous and radioactive substances, have been codified by the US Department of Transportation (DOT, 49 CFR 173) and the US Nuclear Regulatory Commission (NRC, 10 CFR 71). The design requirements for both hazardous [49 CFR 173.24 (e)(1)] and radioactive [49 CFR 173.412 (g)] materials packaging specify packaging compatibility, i.e., that the materials of the packaging at sign d any contents be chemically compatible with each other. Furthermore, Type A [49 CFR 173.412 (g)] and Type B (10 CFR 71.43) packaging design requirements stipulate that there be no significant chemical, galvanic, or other reaction between the materials and contents of the package. Based on these requirements, a Chemical Compatibility Testing Program was developed in the Transportation Systems Department at Sandia National Laboratories (SNL). The program attempts to assure any regulatory body that the issue of packaging material compatibility towards hazardous and radioactive materials has been addressed. This program has been described in considerable detail in an internal SNL document, the Chemical Compatibility Test Plan ampersand Procedure Report (Nigrey 1993)

  9. Is cost-effective healthcare compatible with publicly financed academic medical centres?

    Science.gov (United States)

    Chia, Whay Kuang; Toh, Han Chong

    2013-01-01

    Probably more than any country, Singapore has made significant investment into the biomedical enterprise as a proportion of its economy and size. This focus recently witnessed a shift towards a greater emphasis on translational and clinical development. Key to the realisation of this strategy will be Academic Medical Centres (AMCs), as a principal tool to developing and applying useful products for the market and further improving health outcomes. Here, we explore the principal value proposition of the AMC to Singapore society and its healthcare system. We question if the values inherent within academic medicine--that of inquiry, innovation, pedagogy and clinical exceptionalism--can be compatible with the seemingly paradoxical mandate of providing cost-effective or rationed healthcare.

  10. Pathogen reduction of whole blood: utility and feasibility.

    Science.gov (United States)

    Allain, J-P; Goodrich, R

    2017-10-01

    To collect information on pathogen reduction applied to whole blood. Pathogen reduction (PR) of blood components has been developed over the past two decades, and pathogen-reduced fresh-frozen plasma and platelet concentrates are currently in clinical use. High cost and incomplete coverage of components make PR out of reach for low- and middle-income countries (LMIC). However, should PR become applicable to whole blood (WB), the main product transfused in sub-Saharan Africa, and be compatible with the preparation of clinically suitable components, cost would be minimised, and a range of safety measures in place at high cost in developed areas would become redundant. All articles called with "pathogen reduction", "pathogen inactivation" and "whole blood" were retrieved from Medline. References in articles were utilised. One such PR technology (PRT) applied to WB has been developed and has shown efficacious against viruses, bacteria and parasites in vitro; and has been able to inactivate nucleated blood cells whilst retaining the ability to prepare components with acceptable characteristics. The efficacy of this WB PRT has been demonstrated in vivo using the inactivation of Plasmodium falciparum as a model and showing a high degree of correlation between in vitro and in vivo data. Obtaining further evidence of efficacy on other suitable targets is warranted. Shortening of the process, which is currently around 50 min, or increasing the number of units simultaneously processed would be necessary to make PRT WB conducive to LMIC blood services' needs. Even if not 100% effective against agents that are present in high pathogen load titres, WB PRT could massively impact blood safety in LMIC by providing safer products at an affordable cost. © 2017 British Blood Transfusion Society.

  11. [Blood glucose self monitoring].

    Science.gov (United States)

    Wascher, Thomas C; Stechemesser, Lars

    2016-04-01

    Self monitoring of blood glucose contributes to the integrated management of diabetes mellitus. It, thus, should be available for all patients with diabetes mellitus type-1 and type-2. Self monitoring of blood glucose improves patients safety, quality of life and glucose control. The current article represents the recommendations of the Austrian Diabetes Association for the use of blood glucose self monitoring according to current scientific evidence.

  12. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  13. The effect of strong intermolecular and chemical interactions on the compatibility of polymers

    International Nuclear Information System (INIS)

    Askadskii, Andrei A

    1999-01-01

    The data on compatibility and on the properties of polymer blends are generalised. The emphasis is placed on the formation of strong intermolecular interactions (dipole-dipole interaction and hydrogen bonding) between the components of blends, as well as on the chemical reactions between them. A criterion for the prediction of compatibility of polymers is described in detail. Different cases of compatibility are considered and the dependences of the glass transition temperatures on the composition of blends are analysed. The published data on the effect of strong intermolecular interactions between the blend components on the glass transition temperature are considered. The preparation of interpolymers is described whose macromolecules are composed of incompatible polymers, which leads to the so-called 'forced compatibility.' The bibliography includes 80 references.

  14. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    Science.gov (United States)

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  15. 77 FR 14461 - Approval of Noise Compatibility Program for W.K. Airport, Battle Creek, MI

    Science.gov (United States)

    2012-03-09

    ....K. Kellogg Airport noise compatibility program. All of the recommendations of the program were... Noise Compatibility Program for W.K. Kellogg Airport is February 16, 2012. FOR FURTHER INFORMATION... the Noise Compatibility Program for W.K. Kellogg Airport, effective February 16, 2012. Under section...

  16. 75 FR 11990 - Chicago Executive Airports Noise Exposure Map Approval and Noise Compatibility Program Review

    Science.gov (United States)

    2010-03-12

    ... meet applicable regulations and which depict non-compatible land uses as of the date of submission of... the Act. These functions are inseparable from the ultimate land use control and planning...-compatible land uses and preventing the introduction of additional non-compatible land uses. Interested...

  17. Microbes and blood transfusion

    Directory of Open Access Journals (Sweden)

    Narayan S

    2001-01-01

    Full Text Available Transfusion medicine has been constantly evolving through the years with improved technologies that enhance the capability of identifying existing and newer emerging transfusion transmissible infections (TTI. In spite of the efforts made by blood banks the risk of TTI remains. This article deals with the various steps involved in ensuring blood safety, i.e. donor selection, role of screening donated blood for known and emerging infections, issues and assessment of threat posed by the risk, methodologies employed for testing and possible suggestions to improve transfusion services. While the threat of TTI remains, with a concerted effort of private and government organisations, and co-operation from the diagnostic companies, it is possible to raise the levels of blood safety. A surveillance system is also essential to identify any new agents that might pose a threat in a geographic area and to include them too in the screening process.

  18. Compatibility and Marital Satisfaction in Disabled Couples Compared to Healthy Ones

    Directory of Open Access Journals (Sweden)

    Azam Abed

    2015-06-01

    Full Text Available Objectives: The aim of current study was the evaluation and comparison of compatibility and marital satisfaction between handicapped couples and healthy ones. Methods: In this study, 50 handicapped couples and 50 healthy couples were examined with Enrich’s marital satisfaction questionnaire and Bell’s adjustment questionnaire. The data were analyzed, using SPSS 15, correlation tests and ANOVA. Results: The results showed that there was no significant difference between handicapped and healthy couples in compatibility and marital satisfaction. Discussion: It is concluded that people who were handicapped before their marriage and those who decided to marry them were suitably aware of the issue, therefore accepting a handicapped person was not so hard. What is important in marital compatibility is accepting a partner.

  19. Tumor blood vessel "normalization" improves the therapeutic efficacy of boron neutron capture therapy (BNCT) in experimental oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    D. W. Nigg

    2012-01-01

    We previously demonstrated the efficacy of BNCT mediated by boronophenylalanine (BPA) to treat tumors in a hamster cheek pouch model of oral cancer with no normal tissue radiotoxicity and moderate, albeit reversible, mucositis in precancerous tissue around treated tumors. It is known that boron targeting of the largest possible proportion of tumor cells contributes to the success of BNCT and that tumor blood vessel normalization improves drug delivery to the tumor. Within this context, the aim of the present study was to evaluate the effect of blood vessel normalization on the therapeutic efficacy and potential radiotoxicity of BNCT in the hamster cheek pouch model of oral cancer.

  20. Tumor blood vessel 'normalization' improves the therapeutic efficacy of boron neutron capture therapy (BNCT) in experimental oral cancer

    International Nuclear Information System (INIS)

    Nigg, D.W.

    2012-01-01

    We previously demonstrated the efficacy of BNCT mediated by boronophenylalanine (BPA) to treat tumors in a hamster cheek pouch model of oral cancer with no normal tissue radiotoxicity and moderate, albeit reversible, mucositis in precancerous tissue around treated tumors. It is known that boron targeting of the largest possible proportion of tumor cells contributes to the success of BNCT and that tumor blood vessel normalization improves drug delivery to the tumor. Within this context, the aim of the present study was to evaluate the effect of blood vessel normalization on the therapeutic efficacy and potential radiotoxicity of BNCT in the hamster cheek pouch model of oral cancer.

  1. Work System Assessment to Facilitate the Dissemination of a Quality Improvement Program for Optimizing Blood Culture Use: A Case Study Using a Human Factors Engineering Approach.

    Science.gov (United States)

    Xie, Anping; Woods-Hill, Charlotte Z; King, Anne F; Enos-Graves, Heather; Ascenzi, Judy; Gurses, Ayse P; Klaus, Sybil A; Fackler, James C; Milstone, Aaron M

    2017-11-20

    Work system assessments can facilitate successful implementation of quality improvement programs. Using a human factors engineering approach, we conducted a work system assessment to facilitate the dissemination of a quality improvement program for optimizing blood culture use in pediatric intensive care units at 2 hospitals. Semistructured face-to-face interviews were conducted with clinicians from Johns Hopkins All Children's Hospital and University of Virginia Medical Center. Interview data were analyzed using qualitative content analysis. Blood culture-ordering practices are influenced by various work system factors, including people, tasks, tools and technologies, the physical environment, organizational conditions, and the external environment. A clinical decision-support tool could facilitate implementation by (1) standardizing blood culture-ordering practices, (2) ensuring that prescribing clinicians review the patient's condition before ordering a blood culture, (3) facilitating critical thinking, and (4) empowering nurses to communicate with physicians and advocate for adherence to blood culture-ordering guidelines. The success of interventions for optimizing blood culture use relies heavily on the local context. A work system analysis using a human factors engineering approach can identify key areas to be addressed for the successful dissemination of quality improvement interventions. © The Author 2017. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Progress of the DUPIC Fuel Compatibility Analysis (IV) - Fuel Performance

    International Nuclear Information System (INIS)

    Choi, Hang Bok; Ryu, Ho Jin; Roh, Gyu Hong; Jeong, Chang Joon; Park, Chang Je; Song, Kee Chan; Lee, Jung Won

    2005-10-01

    This study describes the mechanical compatibility of the direct use of spent pressurized water reactor (PWR) fuel in Canada deuterium uranium (CANDU) reactors (DUPIC) fuel, when it is loaded into a CANDU reactor. The mechanical compatibility can be assessed for the fuel management, primary heat transport system, fuel channel, and the fuel handling system in the reactor core by both the experimental and analytic methods. Because the physical dimensions of the DUPIC fuel bundle adopt the CANDU flexible (CANFLEX) fuel bundle design which has already been demonstrated for a commercial use in CANDU reactors, the experimental compatibility analyses focused on the generation of material property data and the irradiation tests of the DUPIC fuel, which are used for the computational analysis. The intermediate results of the mechanical compatibility analysis have shown that the integrity of the DUPIC fuel is mostly maintained under the high power and high burnup conditions even though some material properties like the thermal conductivity is a little lower compared to the uranium fuel. However it is required to slightly change the current DUPIC fuel design to accommodate the high internal pressure of the fuel element. It is also strongly recommended to perform more irradiation tests of the DUPIC fuel to accumulate a database for the demonstration of the DUPIC fuel performance in the CANDU reactor

  3. Progress of the DUPIC Fuel Compatibility Analysis (IV) - Fuel Performance

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hang Bok; Ryu, Ho Jin; Roh, Gyu Hong; Jeong, Chang Joon; Park, Chang Je; Song, Kee Chan; Lee, Jung Won

    2005-10-15

    This study describes the mechanical compatibility of the direct use of spent pressurized water reactor (PWR) fuel in Canada deuterium uranium (CANDU) reactors (DUPIC) fuel, when it is loaded into a CANDU reactor. The mechanical compatibility can be assessed for the fuel management, primary heat transport system, fuel channel, and the fuel handling system in the reactor core by both the experimental and analytic methods. Because the physical dimensions of the DUPIC fuel bundle adopt the CANDU flexible (CANFLEX) fuel bundle design which has already been demonstrated for a commercial use in CANDU reactors, the experimental compatibility analyses focused on the generation of material property data and the irradiation tests of the DUPIC fuel, which are used for the computational analysis. The intermediate results of the mechanical compatibility analysis have shown that the integrity of the DUPIC fuel is mostly maintained under the high power and high burnup conditions even though some material properties like the thermal conductivity is a little lower compared to the uranium fuel. However it is required to slightly change the current DUPIC fuel design to accommodate the high internal pressure of the fuel element. It is also strongly recommended to perform more irradiation tests of the DUPIC fuel to accumulate a database for the demonstration of the DUPIC fuel performance in the CANDU reactor.

  4. Improvement and application of an acute blood stasis rat model aligned with the 3Rs (reduction, refinement and replacement) of humane animal experimentation.

    Science.gov (United States)

    Huang, Shuai; Xu, Feng; Wang, Yin-Ye; Shang, Ming-Ying; Wang, Chao-Qun; Wang, Xuan; Cai, Shao-Qing

    2014-12-23

    To establish a novel cardiocentesis method for withdrawing venous blood from the right atrium, and to improve an acute blood stasis rat model using an ice bath and epinephrine hydrochloride (Epi) while considering the 3Rs (reduction, refinement, and replacement) of humane animal experimentation. An acute blood stasis model was established in male Sprague-Dawley rats by subcutaneous injection (s.c.) Epi (1.2 mg/kg) administration at 0 h, followed by a 5-min exposure to an ice-bath at 2 h and s.c. Epi administration at 4 h. Control rats received physiological saline. Rats were fasted overnight and treated with Angelicae Sinensis Lateralis Radix (ASLR) and Pheretima the following day. Venous blood was collected using our novel cardiocentesis method and used to test whole blood viscosity (WBV), prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen (FIB) content. The rats survived the novel cardiocentesis technique; WBV value returned to normal while hematological parameters such as hemoglobin level and red blood cell count were restored to >94% of the corresponding values in normal rats following a 14-day recovery. Epi (1.2 mg/kg, s.c.) combined with a 5-min exposure to the ice bath replicated the acute blood stasis rat model and was associated with the highest WBV value. In rats showing acute blood stasis, ASLR treatment [4 g/(kg·d) for 8 days] decreased WBV by 9.98%, 11.09%, 9.34%, 9.00%, 7.66%, and 7.03% (P<0.05), while Pheretima treatment [2.6 g/(kg·d), for 8 days] decreased WBV by 25.49%, 25.94%, 16.28%, 17.76%, 11.07%, and 7.89% (P<0.01) at shear rates of 1, 3, 10, 30, 100, and 180 s -1 , respectively. Furthermore, Pheretima treatment increased APTT significantly (P<0.01). We presented a stable, reproducible, and improved acute blood stasis rat model, which could be applied to screen drugs for promoting blood circulation and eliminating blood stasis.

  5. Randomized, Observer-blind, Split-face Compatibility Study with Clindamycin Phosphate 1.2%/Benzoyl Peroxide 3.75% gel and Facial Foundation Makeup.

    Science.gov (United States)

    Bhatia, Neal; Pillai, Radhakrishnan

    2015-09-01

    Cosmetic compatibility in the treatment of acne is an important issue significantly impacting quality of life, but often overlooked, as dermatologists commonly recommended avoidance of cosmetic foundations when treating adult female patients. Fixed combinations of clindamycin/benzoyl peroxide are widely used in the treatment of acne, but little is known about the impact of their concomitant use with facial foundation. To assess the compatibility of clindamycin phosphate 1. 2%/benzoyl peroxide 3. 75% gel with foundation makeup for up to six hours after application. Twenty-nine female subjects applied makeup to their face after randomly applying clindamycin phosphate 1. 2%/benzoyl peroxide 3. 75% gel to one side of the face. Investigator and subject self- assessment included facial skin attributes, facial tolerability, and cosmetic compatibility post-application and at Hour 6; as well as cutaneous tolerability. No statistical difference was noted between the treated and untreated side of the face in terms of coverage, blotchiness, appearance, skin tone, or visual smoothness. Tolerability was excellent, with no erythema, edema, dryness, and peeling post-makeup application. For both the treated and untreated side, there was a slight lack of improvement in cosmetic appearance six hours post-makeup application. Clindamycin/benzoyl peroxide 3. 75% gel was shown to have excellent cosmetic compatibility with facial foundation.

  6. An examination of hospital satisfaction with blood suppliers.

    Science.gov (United States)

    Carden, Robert; DelliFraine, Jami L

    2004-11-01

    The purpose of this study was to identify factors that predict overall hospital satisfaction with blood suppliers. The data for this study came from a 2001 satisfaction survey of hospital blood bank managers conducted by the National Blood Data Resource Center. A total of 1325 blood-utilizing hospitals were included in the final study database. The measurement of hospital satisfaction with its blood supplier encompasses the five composites of the SERVQUAL model. The five composites are 1) tangibles, 2) reliability, 3) responsiveness, 4) assurance, and 5) empathy. Linear regression was performed with overall hospital satisfaction as the dependent variable and the five composites of the SERVQUAL model and control variables as predictors of overall hospital satisfaction with blood suppliers. Significant predictors of hospital satisfaction with blood suppliers are satisfaction with medical and clinical support provided by the blood center, satisfaction with the routine delivery schedule, and price (service fee) of red cells. Prior studies have demonstrated the importance of customer satisfaction to organizations. As organizations, blood centers can benefit from improved satisfaction from their hospital customers. Blood center strategies that focus on improving these three predictors of overall hospital satisfaction with primary blood suppliers will be the most likely to improve and/or maintain hospital customer satisfaction with primary blood suppliers.

  7. Improved fibrosis staging by elastometry and blood test in chronic hepatitis C.

    Science.gov (United States)

    Calès, Paul; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Hubert, Isabelle; Hunault, Gilles; de Lédinghen, Victor; Zarski, Jean-Pierre; Salmon, Dominique; Lunel, Françoise

    2014-07-01

    Our main objective was to improve non-invasive fibrosis staging accuracy by resolving the limits of previous methods via new test combinations. Our secondary objectives were to improve staging precision, by developing a detailed fibrosis classification, and reliability (personalized accuracy) determination. All patients (729) included in the derivation population had chronic hepatitis C, liver biopsy, 6 blood tests and Fibroscan. Validation populations included 1584 patients. The most accurate combination was provided by using most markers of FibroMeter and Fibroscan results targeted for significant fibrosis, i.e. 'E-FibroMeter'. Its classification accuracy (91.7%) and precision (assessed by F difference with Metavir: 0.62 ± 0.57) were better than those of FibroMeter (84.1%, P fibrosis absence (F0) was increased, e.g. from 16.0% with Fibroscan to 75.0% with E-FibroMeter (P test (1.2% of patients) and increasing optimal reliability (accuracy ≥85%) from 80.4% of patients with Fibroscan (accuracy: 90.9%) to 94.2% of patients with E-FibroMeter (accuracy: 92.9%), P test (FibroMeter: 16.2%, P test combination increased: accuracy, globally and especially in patients without fibrosis, staging precision, cirrhosis prediction, and even reliability, thus offering improved fibrosis staging. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Compatibility of copper-electroplated cells with Metal Wrap Through module materials

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, I.J.; Geerligs, L.J.; Olson, C.L.; Goris, M.J.A.A. [ECN Solar Energy, Petten (Netherlands)

    2013-10-16

    As part of the European FP7 RandD project 'Cu-PV', the compatibility of copper-electroplated metal wrapthrough (MWT) cells with conductive adhesives has been investigated. The objectives of this project include to reduce, by the use of copper plating, the amount of silver utilized in cell manufacturing, and to demonstrate the compatibility of high-power n-type back-contact module technology with copper-plated cells. The overall goal is to reduce the impact on the environment of cell and module manufacture. MWT module technology as developed by ECN uses conductive adhesive to make the interconnection between cells and a conductive backsheet foil. These adhesives have been proved to result in very reliable modules in the case of cells with fired silver metallization. To determine the compatibility of conductive adhesive with copper-plated cells, component tests were performed, followed by the manufacture of modules with copperplated cells and conductive adhesive interconnections. Climate chamber testing of these modules showed that the adhesive is compatible with the copper-plated cells. The next steps include further optimization of the plating process and additional testing at the module level.

  9. Deleterious impact of feto-maternal MHC compatibility on the success of pregnancy in a macaque model.

    Science.gov (United States)

    Aarnink, Alice; Mee, Edward T; Savy, Nicolas; Congy-Jolivet, Nicolas; Rose, Nicola J; Blancher, Antoine

    2014-02-01

    The impact of feto-maternal histocompatibility on reproduction has inspired long-lasting debates. However, after the review of numerous articles, the impact of HLA allele sharing within couples on fecundity remains questionable. We decided to explore the impact of major histocompatibility complex (MHC) feto-maternal compatibility on reproduction in a cynomolgus macaque facility composed of animals of Mauritian descent. The Mauritian-derived macaque population presents a very restricted MHC polymorphism (only seven founding haplotypes) due to a strong founding bottleneck effect. The MHC polymorphism was investigated in 237 trios (male, female and offspring) using 17 microsatellite markers distributed across the MHC. Haplotypes were confirmed by segregation analysis. We evaluated the relative frequencies of MHC-compatible and MHC-semi-compatible offspring with the mothers. Among the 237 trios, we selected 42 trios for which the identity of the father is certain and for which the theoretical probabilities of fully compatible and semi-compatible offspring were equal. We found 11 offspring fully compatible and 31 offspring semi-compatible with their respective mother. The observed proportions were clearly outside the interval of confidence of 99 % and therefore most probably resulted from a selection of the semi-compatible offspring during pregnancy. We concluded that MHC fully compatible cynomolgus macaque offspring have a selective survival disadvantage in comparison with offspring inheriting a paternal MHC haplotype differing from maternal haplotypes.

  10. Automatic kelvin probe compatible with ultrahigh vacuum

    NARCIS (Netherlands)

    Baikie, I.D.; van der Werf, Kees; Oerbekke, H.; Broeze, J.; van Silfhout, Arend

    1989-01-01

    This article describes a new type of in situ ultrahigh‐vacuum compatible kelvin probe based on a voice‐coil driving mechanism. This design exhibits several advantages over conventional mechanical feed‐through and (in situ) piezoelectric devices in regard to the possibility of multiple probe

  11. Design of multichannel counting system for IBM PC and compatibles

    International Nuclear Information System (INIS)

    Majeed, B.; Ahmad, Z.; Osman, A.; Ysain, M.M.

    1995-07-01

    A Multichannel Counting System (MCCS), based on IBM-PC and compatible computer systems have been designed. The MCCS consists of a Multichannel Counting System plug-in interface card (MCCS-PC) for IBM PC and compatibles and a NIM-BIN module (MCCS-NB). The MCCS-PC provides simultaneous monitoring of upto seven independent SCA type inputs. An on board programmable timer provides elapsed time measurement. A menu-driven program for data acquisition and timer control has also been developed. (author) 8 figs

  12. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  13. Batch Processing of CMOS Compatible Feedthroughs

    DEFF Research Database (Denmark)

    Rasmussen, F.E.; Heschel, M.; Hansen, Ole

    2003-01-01

    . The feedthrough technology employs a simple solution to the well-known CMOS compatibility issue of KOH by protecting the CMOS side of the wafer using sputter deposited TiW/Au. The fabricated feedthroughs exhibit excellent electrical performance having a serial resistance of 40 mOmega and a parasitic capacitance...... of 2.5 pF. (C) 2003 Elsevier Science B.V. All rights reserved....

  14. Implantable blood pressure sensor for analyzing elasticity in arteries

    Science.gov (United States)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  15. Whole blood pathogen reduction technology and blood safety in sub-Saharan Africa: A systematic review with regional discussion.

    Science.gov (United States)

    Nkohkwo, Asa'ah; Agbor, Gabriel; Asongalem, Emmanuel; Tagny, Claude; Asonganyi, Tazoacha

    2016-01-01

    Despite vast improvements in transfusion services in sub-Saharan Africa over the last decade, there remain serious concerns on the safety and adequacy of the blood supply across the region. This review paper ascertains the role of pathogen reduction technology (PRT) in improving blood safety and supply adequacy in the region. The state of blood safety in sub-Saharan Africa was reviewed. Meetings, seminars and correspondence were undertaken with key clinicians, scientists and professional bodies in the region, including the World Health Organization's Regional Office for Africa, to examine the suitability of PRT for improving the safety of whole blood transfusion, a prevalent transfusion format in the region. Existing literature suggests that combining PRT with current blood safety measures (such as serology) would improve the safety and adequacy of the blood supply for transfusions in sub-Saharan Africa. This was echoed by the findings of the stakeholder meetings. Following a detailed appraisal of two leading PRT systems, the Mirasol ® PRT System and the Cerus S-303 System, we suggest that companies conduct comprehensive toxicological evaluation of the agents used for PRT and publish this in the scientific literature. We also recommend that the safety and efficacy of these technologies should be established in a randomised clinical trial conducted in sub-Saharan Africa.

  16. Exercise training improves blood flow to contracting skeletal muscle of older men via enhanced cGMP signaling

    DEFF Research Database (Denmark)

    Piil, Peter Bergmann; Smith Jørgensen, Tue; Egelund, Jon

    2018-01-01

    Physical activity has the potential to offset age-related impairments in the regulation of blood flow and O2 delivery to the exercising muscles; however, the mechanisms underlying this effect of physical activity remain poorly understood. The present study examined the role of cGMP in training...... a period of aerobic high-intensity exercise training. To determine the role of cGMP signaling, pharmacological inhibition of phosphodiesterase 5 (PDE5) was performed. Before training, inhibition of PDE5 increased (P... group; however, these effects of PDE5 inhibition were not detected after training. These findings suggest a role for enhanced cGMP signaling in the training-induced improvement of regulation of blood flow in contracting skeletal muscle of older men....

  17. [Compatibility of family and profession. Survey of radiologists and medical technical personnel in clinics with different organizations].

    Science.gov (United States)

    Bundy, B D; Bellemann, N; Burkholder, I; Heye, T; Radeleff, B A; Grenacher, L; Kauczor, H U; Weber, M A

    2012-03-01

    The compatibility of family and profession is especially difficult for employees in medical professions because of shift work and overtime. It seems that in the future women are going to represent the majority of medical professionals in Germany. Hence, with the forthcoming lack of physicians in Germany social aspects will also play a greater role in the choice of the place of employment. Therefore a statistical survey was made among employees on how they judge the compatibility of family and job and what they would like to improve. From autumn 2009 until spring 2010 a total of 115 questionnaires were distributed to 8 different academic radiology departments. The anonymous questionnaire with partially open, partially graded questions and partially multiple answer questions was designed with the help of an expert for statistics and analytics and included questions about the employment and family situation, plans for the future, requested flexible working hours and childcare models, as well as ideas for improvement. Of the questionnaires 87 were analyzed with a specially designed access database using, for example descriptive statistics and histogram analyses. Of the interviewees 68% were female and 31% were male (1% not significant n.s.), 46% had children and 49% were childless (5% n.s.), 63% were medical doctors, 33% radiographers (3% other) and 82% worked full-time. Of the male respondents with children 42% indicated that their spouse was at home, 18% of female respondents with children indicated that their spouse was at home and only mothers worked part-time. Of the male respondents 73% would like to take parental leave, 44% of all respondents (70% of the male respondents and 34% of the female respondents) agreed that radiology is more compatible with family than other medical disciplines and 87% would like to have a childcare possibility in close proximity to the working place. In most of the families the classic role model prevails, although women are well

  18. A Zeroth Law Compatible Model to Kerr Black Hole Thermodynamics

    Directory of Open Access Journals (Sweden)

    Viktor G. Czinner

    2017-02-01

    Full Text Available We consider the thermodynamic and stability problem of Kerr black holes arising from the nonextensive/nonadditive nature of the Bekenstein–Hawking entropy formula. Nonadditive thermodynamics is often criticized by asserting that the zeroth law cannot be compatible with nonadditive composition rules, so in this work we follow the so-called formal logarithm method to derive an additive entropy function for Kerr black holes also satisfying the zeroth law’s requirement. Starting from the most general, equilibrium compatible, nonadditive entropy composition rule of Abe, we consider the simplest non-parametric approach that is generated by the explicit nonadditive form of the Bekenstein–Hawking formula. This analysis extends our previous results on the Schwarzschild case, and shows that the zeroth law-compatible temperature function in the model is independent of the mass–energy parameter of the black hole. By applying the Poincaré turning point method, we also study the thermodynamic stability problem in the system.

  19. Patient-centered blood management.

    Science.gov (United States)

    Hohmuth, Benjamin; Ozawa, Sherri; Ashton, Maria; Melseth, Richard L

    2014-01-01

    Transfusions are common in hospitalized patients but carry significant risk, with associated morbidity and mortality that increases with each unit of blood received. Clinical trials consistently support a conservative over a liberal approach to transfusion. Yet there remains wide variation in practice, and more than half of red cell transfusions may be inappropriate. Adopting a more comprehensive approach to the bleeding, coagulopathic, or anemic patient has the potential to improve patient care. We present a patient-centered blood management (PBM) paradigm. The 4 guiding principles of effective PBM that we present include anemia management, coagulation optimization, blood conservation, and patient-centered decision making. PBM has the potential to decrease transfusion rates, decrease practice variation, and improve patient outcomes. PBM's value proposition is highly aligned with that of hospital medicine. Hospitalists' dual role as front-line care providers and quality improvement leaders make them the ideal candidates to develop, implement, and practice PBM. © 2013 Society of Hospital Medicine.

  20. The interface between blood preparation and use in Uganda.

    Science.gov (United States)

    Kajja, I; Bimenya, G; Smit Sibinga, C

    2010-04-01

    The interface between preparation and use of blood impacts directly on the outcome of hemotherapy. The present study explores the knowledge and opinions of key players at, practical realities at, and quality improvement strategies of this interface. We surveyed clinicians (n = 81) and blood bank staff (n = 25) to assess their knowledge on key issues in their counterparts' working domains, the turnaround time on effecting a blood order from a hospital transfusion laboratory and strategies to improve communication of blood needs to blood banks. Out of 81 clinicians, 20 knew the four available blood products while only 17 knew the three uses of these products. Twenty-three blood bank staff reported the patient's condition as the main factor on which blood orders are based. Forty-four (54.3%) clinicians reported reception of a blood product within an hour of placing the order. Addressing infrastructure and human resource were some of the strategies suggested to improve this step of the transfusion chain. The knowledge of staff at the extreme ends of the clinical interface in their counterparts' working domain is far from adequate. However, they have well formed opinions on strategies to improve this interface.

  1. Bloody Fast Blood Collection

    NARCIS (Netherlands)

    van Brummelen, Samuel Pieter Josephus

    2017-01-01

    This thesis consists of four parts: The first part contains an introduction, the second presents approaches for the evaluation of waiting times at blood collection sites, the third uses these to present approaches that improve waiting times at blood collection sites. The final part shows the

  2. Whole blood pathogen reduction technology and blood safety in sub-Saharan Africa: A systematic review with regional discussion

    OpenAIRE

    Nkohkwo, Asa?ah; Agbor, Gabriel; Asongalem, Emmanuel; Tagny, Claude; Asonganyi, Tazoacha

    2016-01-01

    Background: Despite vast improvements in transfusion services in sub-Saharan Africa over the last decade, there remain serious concerns on the safety and adequacy of the blood supply across the region. Objective: This review paper ascertains the role of pathogen reduction technology (PRT) in improving blood safety and supply adequacy in the region. Method: The state of blood safety in sub-Saharan Africa was reviewed. Meetings, seminars and correspondence were undertaken with key clinic...

  3. Tumor blood flow, pO2, and radioresponse are improved by mild temperature hyperthermia

    International Nuclear Information System (INIS)

    Shakil, Abdus; Griffin, Robert J.; Song, Chang W.

    1997-01-01

    Purpose/Objective: The purpose of this study was to elucidate the changes in tumor blood flow, tumor pO 2 and the radiation response of the tumors caused by mild temperature hyperthermia (MTH). Materials And Methods: Experiments were carried out using the R3230 Adenocarcinoma (R3230 AC tumor), grown subcutaneously in the right hind limbs of male Fischer rats. Tumors were heated once at 40.5 deg.to 43.5 deg.C for 30 or 60 min, or twice at a 24 hr interval. Tumor blood flow and tumor pO 2 were measured immediately after the hyperthermic treatments or after 24 hr using a radioactive microsphere method and by an Eppendorf pO 2 Histograph, respectively. The influence of MTH on the effect of X-irradiation (250 kVp) on this tumor was investigated with tumor growth delay and the in vivo/in vitro excision assay for surviving tumor cell fraction. Results: Tumor blood flow and pO 2 increased upon heating for 30 min at 40.5 deg.C to 43.5 deg.C, but following 60 min heating, the pO 2 was similar to that in control tumors. The tumor blood flow increased about 1.4-fold and the tumor pO 2 increased more than 3 times after 30 min heating at 42.5 deg.C. Therefore, the in vivo/in vitro assay and the growth delay were carried out following treatment with 42.5 deg.C for 30 min. As shown in Table 1, the reduction in surviving fraction by MTH before radiation was markedly greater than that by MTH after radiation. Table 1 also shows that MTH alone caused no growth delay compared to control and while heat after radiation increased the growth delay by 2 days, MTH before radiation increased the growth delay by 5 days compared to radiation alone. Conclusion: The results indicate that MTH is effective in increasing tumor blood flow and oxygenation and that MTH for 30 min at 42.5 deg.C, applied before radiation, significantly improves the radiation response of R3230 AC tumors

  4. Coal use in Italy and environmental compatibility

    International Nuclear Information System (INIS)

    1998-01-01

    Fossil fuels have in Italy great importance. In Italy, in terms of environmental protection and for social acceptance, coal has had a real opposition not verified in other countries. Environmental compatibility of coal cycle and related technologies are discussed also consequently at the Kyoto protocol [it

  5. Covalently bound conjugates of albumin and heparin: Synthesis, fractionation and characterization

    NARCIS (Netherlands)

    Hennink, Wim E.; Feijen, Jan; Ebert, Charles D.; Kim, Sung Wan

    1983-01-01

    Covalently bound conjugates of human serum albumin and heparin were prepared as compounds which could improve the blood-compatibility of polymer surfaces either by preadsorption or by covalent coupling of the conjugates onto blood contacting surfaces. The conjugates (10–16 weight % of heparin) were

  6. Mixed waste chemical compatibility with packaging components

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Conroy, M.; Blalock, L.B.

    1994-01-01

    In this paper, a chemical compatibility testing program for packaging of mixed wastes at will be described. We will discuss the choice of four y-radiation doses, four time durations, four temperatures and four waste solutions to simulate the hazardous waste components of mixed wastes for testing materials compatibility of polymers. The selected simulant wastes are (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. A selection of 10 polymers with anticipated high resistance to one or more of these types of environments are proposed for testing as potential liner or seal materials. These polymers are butadiene acrylonitrile copolymer, cross-linked polyethylene, epichlorhyarin, ethylene-propylene rubber, fluorocarbon, glass-filled tetrafluoroethylene, high-density poly-ethylene, isobutylene-isoprene copolymer, polypropylene, and styrene-butadiene rubber. We will describe the elements of the testing plan along with a metric for establishing time resistance of the packaging materials to radiation and chemicals

  7. Recent materials compatibility studies in refractory metal-alkali metal systems for space power applications.

    Science.gov (United States)

    Harrison, R. W.; Hoffman, E. E.; Davies, R. L.

    1972-01-01

    Advanced Rankine and other proposed space power systems utilize refractory metals in contact with both single-phase and two-phase alkali metals at elevated temperatures. A number of recent compatibility experiments are described which emphasize the excellent compatibility of refractory metals with the alkali metals, lithium, sodium, and potassium, under a variety of environmental conditions. The alkali metal compatibilities of tantalum-, columbium-, molybdenum-, and tungsten-base alloys are discussed.

  8. Compatibility approach for the improvement of oxide thermoelectric converters for industrial heat recovery applications

    Science.gov (United States)

    Saucke, Gesine; Populoh, Sascha; Thiel, Philipp; Xie, Wenjie; Funahashi, Ryoji; Weidenkaff, Anke

    2015-07-01

    New ceramic Ca3Co3.9O9+δ /CaMn0.97W0.03O3-δ thermoelectric generators with different cross section areas A p and A n of the p- and the n-type leg are fabricated, characterized, and tested at high temperatures in long-term tests. The variation of the measured power output and the efficiency with changing A p / A n ratio is discussed and compared with calculations based on the measured material properties. The highest conversion efficiencies are reached for ratios close to the one predicted by the compatibility approach, whereas an improper choice of A p / A n leads to a strong reduction of the efficiency. A volume power density of 1.4 W/cm3 and an efficiency of 1.08% are found for the most promising generator (temperature difference Δ T = 734 K and A p / A n = 1.12). The results reveal the major importance of the A p / A n ratio for the conversion efficiency and subsequently cost and weight reduction issues, both crucial for a large scale application of thermoelectric converters. Additionally, the oxide generators proved to be very reliable, as after more than 110 h of high temperature energy conversion, no degradation is observable.

  9. Blood Pressure Directed Booster Trainings Improve Intensive Care Unit Provider Retention of Excellent Cardiopulmonary Resuscitation Skills.

    Science.gov (United States)

    Wolfe, Heather; Maltese, Matthew R; Niles, Dana E; Fischman, Elizabeth; Legkobitova, Veronika; Leffelman, Jessica; Berg, Robert A; Nadkarni, Vinay M; Sutton, Robert M

    2015-11-01

    Brief, intermittent cardiopulmonary resuscitation (CPR) training sessions, "Booster Trainings," improve CPR skill acquisition and short-term retention. The objective of this study was to incorporate arterial blood pressure (ABP) tracings into Booster Trainings to improve CPR skill retention. We hypothesized that ABP-directed CPR "Booster Trainings" would improve intensive care unit (ICU) provider 3-month retention of excellent CPR skills without need for interval retraining. A CPR manikin creating a realistic relationship between chest compression depth and ABP was used for training/testing. Thirty-six ICU providers were randomized to brief, bedside ABP-directed CPR manikin skill retrainings: (1) Booster Plus (ABP visible during training and testing) versus (2) Booster Alone (ABP visible only during training, not testing) versus (3) control (testing, no intervention). Subjects completed skill tests pretraining (baseline), immediately after training (acquisition), and then retention was assessed at 12 hours, 3 and 6 months. The primary outcome was retention of excellent CPR skills at 3 months. Excellent CPR was defined as systolic blood pressure of 100 mm Hg or higher and compression rate 100 to 120 per minute. Overall, 14 of 24 (58%) participants acquired excellent CPR skills after their initial training (Booster Plus 75% vs 50% Booster Alone, P = 0.21). Adjusted for age, ABP-trained providers were 5.2× more likely to perform excellent CPR after the initial training (95% confidence interval [95% CI], 1.3-21.2; P = 0.02), and to retain these skills at 12 hours (adjusted odds ratio, 4.4; 95% CI, 1.3-14.9; P = 0.018) and 3 months (adjusted odds ratio, 4.1; 95% CI, 1.2-13.9; P = 0.023) when compared to baseline performance. The ABP-directed CPR booster trainings improved ICU provider 3-month retention of excellent CPR skills without the need for interval retraining.

  10. Characterization of Type-II Acetylated Cellulose Nanocrystals with Various Degree of Substitution and Its Compatibility in PLA Films

    Directory of Open Access Journals (Sweden)

    Feng Dong

    2017-08-01

    Full Text Available In order to decrease the self-agglomeration and improve the hydrophobic properties of type-II acetylated cellulose nanocrystals (ACNC II, various degree of substitution (DS values of ACNCs were successfully prepared by a single-step method from microcrystalline cellulose with anhydrous phosphoric acid as the solvent, and acetic anhydride as the acetylation reagent, under different reaction temperatures (20–40 °C. To thoroughly investigate the DS values of ACNC II, analyses were performed using Fourier transform infrared spectroscopy (FT-IR, 13C cross polarization-magic angle spinning (CP-MAS nuclear magnetic resonance (NMR, and X-ray photoelectron spectroscopy (XPS. At a reaction temperature of 40°C, the highest DS value was successfully obtained. XRD proved that the crystal structure of ACNC II with various DS values was maintained after acetylation. TEM showed the threadlike shape for ACNC II with various DS values. The ACNC II with various DS values was introduced into a polylactic acid (PLA matrix to produce PLA/ACNC composite films, which showed improved rheological and thermal properties. This improvement was primarily attributed to good dispersion of the ACNC II, and the interfacial compatibility between ACNC II and the PLA matrix. This study aims to analyze the compatibility of ACNC II with various DS values in the PLA matrix by microstructure, crystallization, and rheological and thermal tests.

  11. Interventions for improving modifiable risk factor control in the secondary prevention of stroke.

    Science.gov (United States)

    Lager, Kate E; Mistri, Amit K; Khunti, Kamlesh; Haunton, Victoria J; Sett, Aung K; Wilson, Andrew D

    2014-05-02

    People with stroke or transient ischaemic attack (TIA) are at increased risk of future stroke and other cardiovascular events. Evidence-based strategies for secondary stroke prevention have been established. However, the implementation of prevention strategies could be improved. To assess the effects of stroke service interventions for implementing secondary stroke prevention strategies on modifiable risk factor control, including patient adherence to prescribed medications, and the occurrence of secondary cardiovascular events. We searched the Cochrane Stroke Group Trials Register (April 2013), the Cochrane Effective Practice and Organisation of Care Group Trials Register (April 2013), CENTRAL (The Cochrane Library 2013, issue 3), MEDLINE (1950 to April 2013), EMBASE (1981 to April 2013) and 10 additional databases. We located further studies by searching reference lists of articles and contacting authors of included studies. We included randomised controlled trials (RCTs) that evaluated the effects of organisational or educational and behavioural interventions (compared with usual care) on modifiable risk factor control for secondary stroke prevention. Two review authors selected studies for inclusion and independently extracted data. One review author assessed the risk of bias for the included studies. We sought missing data from trialists. This review included 26 studies involving 8021 participants. Overall the studies were of reasonable quality, but one study was considered at high risk of bias. Fifteen studies evaluated predominantly organisational interventions and 11 studies evaluated educational and behavioural interventions for patients. Results were pooled where appropriate, although some clinical and methodological heterogeneity was present. The estimated effects of organisational interventions were compatible with improvements and no differences in the modifiable risk factors mean systolic blood pressure (mean difference (MD) -2.57 mmHg; 95% confidence

  12. Desk-top publishing using IBM-compatible computers.

    Science.gov (United States)

    Grencis, P W

    1991-01-01

    This paper sets out to describe one Medical Illustration Departments' experience of the introduction of computers for desk-top publishing. In this particular case, after careful consideration of all the options open, an IBM-compatible system was installed rather than the often popular choice of an Apple Macintosh.

  13. Cord Blood

    Directory of Open Access Journals (Sweden)

    Saeed Abroun

    2014-05-01

    user centers are few, we hope in all providence the transplantation center will establish by good activity to improve social welfare. Key words: Bone marrow, Cord blood, Peripheral blood.

  14. Compatibility and economic assessment of sweetpotato and garden ...

    African Journals Online (AJOL)

    ecological zone of Nigeria, to determine the compatibility and economic viability of sweetpotato (Ipomoea batatas) and garden egg (Solanum gelio) intercrop during 2011 and 2012 cropping seasons. Two sweetpotato varieties; NR05/022 and ...

  15. Comparison of blood flow and cell function in ischemic skin flaps

    International Nuclear Information System (INIS)

    Bean, D.; Rees, R.S.; O'Leary, J.P.; Lynch, J.B.

    1984-01-01

    Cellular function and blood flow in acute, steroid-treated, and surgically delayed random skin flaps have been examined. In these studies, the period following flap elevation could be divided into early (0-2 hr), intermediate (4-6 hr), and late (12 hr) periods of ischemia, based on the cutaneous blood flow and cellular function measured by thallium-201 uptake. There was a close correlation between blood flow and cellular function during the early period of ischemia which became worse with time. Blood flow studies demonstrated a significant difference between the early and intermediate periods of ischemia which was abolished by surgical delay. Improvement in cellular function was accomplished by improved blood flow in the surgically delayed flaps, while steroid-treated flaps enhanced cellular metabolism by another mechanism. Cellular function approximated blood flow during the early and immediate period of ischemia. Steroids may augment cellular function without improving blood flow, while surgical delay improves cellular function by improving blood flow

  16. Improved Ion-Channel Biosensors

    Science.gov (United States)

    Nadeau, Jay; White, Victor; Dougherty, Dennis; Maurer, Joshua

    2004-01-01

    An effort is underway to develop improved biosensors of a type based on ion channels in biomimetic membranes. These sensors are microfabricated from silicon and other materials compatible with silicon. As described, these sensors offer a number of advantages over prior sensors of this type.

  17. A practical exact maximum compatibility algorithm for reconstruction of recent evolutionary history.

    Science.gov (United States)

    Cherry, Joshua L

    2017-02-23

    Maximum compatibility is a method of phylogenetic reconstruction that is seldom applied to molecular sequences. It may be ideal for certain applications, such as reconstructing phylogenies of closely-related bacteria on the basis of whole-genome sequencing. Here I present an algorithm that rapidly computes phylogenies according to a compatibility criterion. Although based on solutions to the maximum clique problem, this algorithm deals properly with ambiguities in the data. The algorithm is applied to bacterial data sets containing up to nearly 2000 genomes with several thousand variable nucleotide sites. Run times are several seconds or less. Computational experiments show that maximum compatibility is less sensitive than maximum parsimony to the inclusion of nucleotide data that, though derived from actual sequence reads, has been identified as likely to be misleading. Maximum compatibility is a useful tool for certain phylogenetic problems, such as inferring the relationships among closely-related bacteria from whole-genome sequence data. The algorithm presented here rapidly solves fairly large problems of this type, and provides robustness against misleading characters than can pollute large-scale sequencing data.

  18. Electromagnetic compatibility principles and applications

    CERN Document Server

    Weston, David A

    2001-01-01

    This totally revised and expanded reference/text provides comprehensive, single-source coverage of the design, problem solving, and specifications of electromagnetic compatibility (EMC) into electrical equipment/systems-including new information on basic theories, applications, evaluations, prediction techniques, and practical diagnostic options for preventing EMI through cost-effective solutions. Offers the most recent guidelines, safety limits, and standards for human exposure to electromagnetic fields! Containing updated data on EMI diagnostic verification measurements, as well as over 900 drawings, photographs, tables, and equations-500 more than the previous edition

  19. Can mHealth improve access to safe blood for transfusion during obstetric emergency?

    Directory of Open Access Journals (Sweden)

    Rahman A

    2017-04-01

    Full Text Available Aminur Rahman,1,2 Sadika Akhter,1 Monjura Khatun Nisha,3 Syed Shariful Islam,4 Fatema Ashraf,5 Monjur Rahman,1 Nazneen Begum,6 Mahbub Elahi Chowdhury,1 Anne Austin,7 Iqbal Anwar1 1International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b, Dhaka, Bangladesh; 2College of Public Health Sciences, Chulalongkorn University, Bangkok, Thailand; 3Sydney School of Public Health, Sydney Medical School, The University of Sydney, Sydney, NSW, Australia; 4Department of Public Health and Informatics, Bangabandhu Sheikh Mujib Medical University, 5Department of Gyenaecology and Obstetric, Shaheed Suhrawardi Medical College and Hospital, 6Department of Gyenaecology and Obstetric, Dhaka Medical College and Hospital, Dhaka, Bangladesh; 7JSI Research & Training Institute, Inc., Boston, MA, USA Purpose: Of the 99% maternal deaths that take place in developing countries, one-fourth is due to postpartum hemorrhage (PPH. PPH accounts for one-third of all blood transfusions in Bangladesh where the transfusion process is lengthy as most facilities do not have in-house blood bank facilities. In this context, the location where blood is obtained and the processes of obtaining blood products are not standardized, leading to preventable delays in collecting blood, when it is needed. This study evaluated the effectiveness of an online Blood Information Management Application (BIMA system for reducing lag time in the blood transfusion process.Patients and methods: The study was conducted in a public medical college hospital in Dhaka, Bangladesh, and in two proximate, licensed blood banks between January 2014 and March 2015, using a before after design. A total of 310 women (143 before and 177 after, who needed emergency blood transfusion during their perinatal period, as determined by a medical professional, were included in the study. A median linear regression model was employed to assess the adjusted effect of BIMA on transfusion time.Results: After the

  20. Genetic Compatibility Underlies Benefits of Mate Choice in an External Fertilizer.

    Science.gov (United States)

    Aguirre, J David; Blows, Mark W; Marshall, Dustin J

    2016-05-01

    Mate choice is a common feature of sexually reproducing species. In sessile or sedentary external fertilizers, however, direct interactions between reproductive partners are minimal, and instead mate recognition and choice must occur at the level of gametes. It is common for some sperm and egg combinations to have higher fertilization success than others, but it remains unclear whether differences in fertilization reflect gamete-level mate choice (GMC) for paternal quality or parental compatibility. Here, we examine the mechanisms underlying GMC in an externally fertilizing ascidian. A manipulative mate-choice assay confirmed that offspring viability was greater in clutches where we allowed GMC than in clutches where we precluded GMC. A complementary quantitative genetic experiment then revealed that paternal quality effects were generally weaker than parental compatibility effects, particularly for the trait combination underlying the benefits of GMC. Overall, our data suggest that gametes that are more compatible at fertilization produce more viable offspring than gametes that are less compatible at fertilization. Therefore, although the regalia we typically associate with sexual selection are absent in external fertilizers, mechanisms that allow females to bias fertilization in favor of some males over others produce significant fitness benefits in organisms reproducing via the ancestral strategy.

  1. A review of compatibility of IFR fuel and austenitic stainless steel

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.

    1996-01-01

    Interdiffusion experiments have been conducted to investigate the compatibility of various austenitic stainless steels with U-Pu-Zr alloys, which are alloys to be employed as fuel for the Integral Fast Reactor being developed by Argonne National Laboratory. These tests have also studied the compatibility of austenitic stainless steels with fission products, like the minor actinides (Np and Am) and lanthanides (Ce and Nd), that are generated during the fission process in an IFR. This paper compares the results of these investigations in the context of fuel-cladding compatibility in IFR fuel elements, specifically focusing on the relative Interdiffusion behavior of the components and the types of phases that develop based on binary phase diagrams. Results of Interdiffusion tests are assessed in the light of observations derived from post-test examinations of actual irradiated fuel elements

  2. Technology for the compatible integration of silicon detectors with readout electronics

    International Nuclear Information System (INIS)

    Zimmer, G.

    1984-01-01

    Compatible integration of detectors and readout electronics on the same silicon substrate is of growing interest. As the methods of microelectronics technology have already been adapted for detector fabrication, a common technology basis for detectors and readout electronics is available. CMOS technology exhibits most attractive features for the compatible realization of readout electronics when advanced LSI processing steps are combined with detector requirements. The essential requirements for compatible integration are the availability of high resistivity (100)-oriented single crystalline silicon substrate, the formation of suitably doped areas for MOS circuits and the isolation of the low voltage circuit from the detector operated at much higher supply voltage. Junction isolation as a first approach based on present production technology and dielectric isolation based on an advanced SOI-LSI technology are discussed as the most promising solutions for present and future applications, respectively. (orig.)

  3. Globalisation and international compatibility - a challenge to ...

    African Journals Online (AJOL)

    The contexts of institutions for higher education are in flux with consequent learning challenges. One of these challenges is that of globalisation and the need for international compatibility. Another challenge is that Mode 2 learning programmes, material and methods need to be relevant to the specific context in which they ...

  4. Progress in the blood supply of Afghanistan.

    Science.gov (United States)

    Riley, William J; McCullough, Terri Konstenius; Rhamani, Ahmad Masoud; McCullough, Jeffrey

    2017-07-01

    The blood supply system in Afghanistan was badly damaged by years of conflict. In 2009, the Afghanistan National Blood Safety and Transfusion Service (ANBSTS) was established. For 6 years, we collaborated to assist with policy and infrastructure development; blood bank operations; blood collection, testing, and component production; transfusion practices; and training of technicians, nurses, midwives, and physicians. Policies were established, infrastructure was strengthened, and capable staff was acquired and trained. Standard operating procedures were developed, testing was improved, and quality systems were established. Thirty trainings were held for blood center staff. Four additional formal trainings were held for 39 physicians, 36 nurses and/or midwives, and 38 laboratory technicians. During 5 years of this project, blood collection increased by 40%. The ANBSTS has made impressive progress developing infrastructure, personnel, procedures, quality systems, and training programs and increasing blood collection. Knowledge of transfusion medicine was improved through structured training. © 2017 AABB.

  5. Evaluation of Pb–17Li compatibility of ODS Fe-12Cr-5Al alloys

    Energy Technology Data Exchange (ETDEWEB)

    Unocic, Kinga A., E-mail: unocicka@ornl.gov; Hoelzer, David T.

    2016-10-15

    The Dual Coolant Lead Lithium (DCLL: eutectic Pb–17Li and He) blanket concept requires improved Pb–17Li compatibility with ferritic steels in order to demonstrate acceptable performance in fusion reactors. As an initial step, static Pb-17at.%Li (Pb-17Li) capsule experiments were conducted on new oxide dispersion strengthened (ODS) FeCrAl alloys ((1) Y{sub 2}O{sub 3} (125Y), (2) Y{sub 2}O{sub 3} + ZrO{sub 2} (125YZ), (3) Y{sub 2}O{sub 3} + HfO{sub 2} (125YH), and (4) Y{sub 2}O{sub 3} + TiO{sub 2} (125YT)) produced at ORNL via mechanical alloying (MA). Tests were conducted in static Pb–17Li for 1000 h at 700 °C. Alloys showed promising compatibility with Pb–17Li with small mass change after testing for 125YZ, 125YH and 125YT, while the 125Y alloy experienced the highest mass loss associated with some oxide spallation and subsequent alloy dissolution. X-ray diffraction methods identified the surface reaction product as LiAlO{sub 2} on all four alloys. A small decrease (∼1 at.%) in Al content beneath the oxide scale was observed in all four ODS alloys, which extended 60 μm beneath the oxide/metal interface. This indicates improvements in alloy dissolution by decreasing the amount of Al loss from the alloy. Scales formed on 125YZ, 125YH and 125YT were examined via scanning transmission electron microscopy (S/TEM) and revealed incorporation of Zr-, Hf-, and Ti-rich precipitates within the LiAlO{sub 2} product, respectively. This indicates an inward scale growth mechanism. Future work in flowing Pb–17Li is needed to further evaluate the effectiveness of this strategy in a test blanket module. - Highlights: • Investigation of Pb-17Li compatibility of new ODS Fe-12Cr5Al. • Promising small mass change after static Pb-17Li exposure. • LiAlO{sub 2} formed on the surface during Pb-17Li exposure. • Oxide precipitates incorporated within the LiAlO{sub 2} product. • An inward scale growth mechanism was identified.

  6. Mobilized peripheral blood stem cells compared with bone marrow from HLA-identical siblings for reduced-intensity conditioning transplantation in acute myeloid leukemia in complete remission

    DEFF Research Database (Denmark)

    Nagler, Arnon; Labopin, Myriam; Shimoni, Avichai

    2012-01-01

    Reduced-intensity conditioning (RIC)-alloSCT is increasingly used for acute myelogenous leukemia. Limited data are available for the comparison of peripheral blood stem cells with bone marrow for RIC-alloSCT. We used the European Group for Blood and Marrow Transplantation (EBMT) ALWP data...... to compare the outcome of mobilized peripheral blood stem cells (PBSC) (n = 1430) vs. bone marrow (BM) (n = 107) for acute myelogenous leukemia (AML) patients with complete remission that underwent RIC-alloSCT from compatible sibling donors. The leukemia features, the disease status, and the time from...

  7. Materials compatibility and corrosion issues for accelerator transmutation of waste

    International Nuclear Information System (INIS)

    Staudhammer, K.

    1992-08-01

    The need to understand the materials issues in an accelerator transmutation of waste (ATW) system is essential. This report focuses on the spallation container material, as this material is exposed to some of the most crucial environmental conditions of simultaneous radiation and corrosion in the system. The most severe design being considered is that of liquid lead. In previous investigations of lead compatibility with materials, the chemistry of the system was derived solely from the corrosion products; however, in an ATW system, the chemistry of the lead changes not only with the derived corrosion products of the material being tested but also with the buildup of the daughter production with time. Daughter production builds up and introduces elements that may have a great effect on the corrosion activity of the liquid lead. Consequently, data on liquid lead compatibility can be regarded only as a guide and must be reevaluated when particular daughter products are added. This report is intended to be a response to specific materials issues and concerns expressed by the ATW design working group and addresses the compatibility/corrosion concerns

  8. A compatible electrocutaneous display for functional magnetic resonance imaging application.

    Science.gov (United States)

    Hartwig, V; Cappelli, C; Vanello, N; Ricciardi, E; Scilingo, E P; Giovannetti, G; Santarelli, M F; Positano, V; Pietrini, P; Landini, L; Bicchi, A

    2006-01-01

    In this paper we propose an MR (magnetic resonance) compatible electrocutaneous stimulator able to inject an electric current, variable in amplitude and frequency, into the fingertips in order to elicit tactile skin receptors (mechanoreceptors). The desired goal is to evoke specific tactile sensations selectively stimulating skin receptors by means of an electric current in place of mechanical stimuli. The field of application ranges from functional magnetic resonance imaging (fMRI) tactile studies to augmented reality technology. The device here proposed is designed using safety criteria in order to comply with the threshold of voltage and current permitted by regulations. Moreover, MR safety and compatibility criteria were considered in order to perform experiments inside the MR scanner during an fMRI acquisition for functional brain activation analysis. Psychophysical laboratory tests are performed in order to define the different evoked tactile sensation. After verifying the device MR safety and compatibility on a phantom, a test on a human subject during fMRI acquisition is performed to visualize the brain areas activated by the simulated tactile sensation.

  9. Cell-compatible conducting polyaniline films prepared in colloidal dispersion mode.

    Science.gov (United States)

    Kašpárková, Věra; Humpolíček, Petr; Capáková, Zdenka; Bober, Patrycja; Stejskal, Jaroslav; Trchová, Miroslava; Rejmontová, Petra; Junkar, Ita; Lehocký, Marián; Mozetič, Miran

    2017-09-01

    Conducting polyaniline can be prepared and modified using several procedures, all of which can significantly influence its applicability in different fields of biomedicine or biotechnology. The modifications of surface properties are crucial with respect to the possible applications of this polymer in tissue engineering or as biosensors. Innovative technique for preparing polyaniline films via in-situ polymerization in colloidal dispersion mode using four stabilizers (poly-N-vinylpyrrolidone; sodium dodecylsulfate; Tween 20 and Pluronic F108) was developed. The surface energy, conductivity, spectroscopic features, and cell compatibility of thin polyaniline films were determined using contact-angle measurement, the van der Pauw method, Fourier-transform infrared spectroscopy, and assay conducted on mouse fibroblasts, respectively. The stabilizers significantly influenced not only the surface and electrical properties of the films but also their cell compatibility. Sodium dodecylsulfate seems preferentially to combine both the high conductivity and good cell compatibility. Moreover, the films with sodium dodecylsulfate were non-irritant for skin, which was confirmed by their in-vitro exposure to the 3D-reconstructed human tissue model. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Human Heart Pulse Wave Responses Measured Simultaneously at Several Sensor Placements by Two MR-Compatible Fibre Optic Methods

    Directory of Open Access Journals (Sweden)

    Teemu Myllylä

    2012-01-01

    Full Text Available This paper presents experimental measurements conducted using two noninvasive fibre optic methods for detecting heart pulse waves in the human body. Both methods can be used in conjunction with magnetic resonance imaging (MRI. For comparison, the paper also performs an MRI-compatible electrocardiogram (ECG measurement. By the simultaneous use of different measurement methods, the propagation of pressure waves generated by each heart pulse can be sensed extensively in different areas of the human body and at different depths, for example, on the chest and forehead and at the fingertip. An accurate determination of a pulse wave allows calculating the pulse transit time (PTT of a particular heart pulse in different parts of the human body. This result can then be used to estimate the pulse wave velocity of blood flow in different places. Both measurement methods are realized using magnetic resonance-compatible fibres, which makes the methods applicable to the MRI environment. One of the developed sensors is an extraordinary accelerometer sensor, while the other one is a more common sensor based on photoplethysmography. All measurements, involving several test patients, were performed both inside and outside an MRI room. Measurements inside the MRI room were conducted using a 3-Tesla strength closed MRI scanner in the Department of Diagnostic Radiology at the Oulu University Hospital.

  11. Directional control-response compatibility of joystick steered shuttle cars.

    Science.gov (United States)

    Burgess-Limerick, Robin; Zupanc, Christine M; Wallis, Guy

    2012-01-01

    Shuttle cars are an unusual class of vehicle operated in underground coal mines, sometimes in close proximity to pedestrians and steering errors may have very serious consequences. A directional control-response incompatibility has previously been described in shuttle cars which are controlled using a steering wheel oriented perpendicular to the direction of travel. Some other shuttle car operators are seated perpendicular to the direction of travel and steer the car via a seat mounted joystick. A virtual simulation was utilised to determine whether the steering arrangement in these vehicles maintains directional control-response compatibility. Twenty-four participants were randomly assigned to either a condition corresponding to this design (consistent direction), or a condition in which the directional steering response was reversed while driving in-bye (visual field compatible). Significantly less accurate steering performance was exhibited by the consistent direction group during the in-bye trials only. Shuttle cars which provide the joystick steering mechanism described here require operators to accommodate alternating compatible and incompatible directional control-response relationships with each change of car direction. A virtual simulation of an underground coal shuttle car demonstrates that the design incorporates a directional control-response incompatibility when driving the vehicle in one direction. This design increases the probability of operator error, with potential adverse safety and productivity consequences.

  12. Nitrate administration increases blood flow in dysfunctional but viable myocardium, leading to improved assessment of myocardial viability : A PET study

    NARCIS (Netherlands)

    Slart, Riemer H. J. A.; Agool, Ali; van Veldhuisen, Dirk J.; Dierckx, Rudi A.; Bax, Jeroen J.

    SPECT with Tc-99m-labeled agents is better able to detect viability after nitrate administration. Nitrates induce vasoclilation and may increase blood flow to severely hypoperfused but viable myocardium, thereby enhancing tracer delivery and improving the detection of viability. Quantitative data on

  13. LHCb: LHCb Software and Conditions Database Cross-Compatibility Tracking: a Graph-Theory Approach

    CERN Multimedia

    Cattaneo, M; Shapoval, I

    2012-01-01

    The Conditions Database (CondDB) of the LHCb experiment provides versioned, time dependent geometry and conditions data or all LHCb data processing applications (simulation, high level trigger, reconstruction, analysis). The evolution of CondDB and of the LHCb applications is a weakly-homomorphic process. It means that compatibility between a CondDB state and LHCb application state may not be preserved across different database and application generations. More over, a CondDB state by itself belongs to a complex three-dimensional phase space which evolves according to certain CondDB self-compatibility criteria, so it is sometimes difficult even to determine a self-consistent CondDB state. These compatibility issues may lead to various kinds of problems in the LHCb production, varying from unexpected application crashes to incorrect data processing results. Thus, there is a need for defining a well-established set of compatibility criteria between mentioned above entities, together with developing a compatibil...

  14. LHCb Software and Conditions Database Cross-Compatibility Tracking System: a Graph-Theory Approach

    CERN Document Server

    Cattaneo, M; Shapoval, I

    2012-01-01

    The Conditions Database (CondDB) of the LHCb experiment provides versioned, time dependent geometry and conditions data or all LHCb data processing applications (simulation, high level trigger, reconstruction, analysis). The evolution of CondDB and of the LHCb applications is a weakly-homomorphic process. It means that compatibility between a CondDB state and LHCb application state may not be preserved across different database and application generations. More over, a CondDB state by itself belongs to a complex three-dimensional phase space which evolves according to certain CondDB self-compatibility criteria, so it is sometimes difficult even to determine a self-consistent CondDB state. These compatibility issues may lead to various kinds of problems in the LHCb production, varying from unexpected application crashes to incorrect data processing results. Thus, there is a need for defining a well-established set of compatibility criteria between mentioned above entities, together with developing a compatibil...

  15. Peroxidase Activity in Poplar Inoculated with Compatible and Incompetent Isolates of Paxillus involutus

    Directory of Open Access Journals (Sweden)

    ABDUL GAFUR

    2007-06-01

    Full Text Available Peroxidase activity of the hybrid poplar Populus×canescens (Ait. Sm. (= P. tremula L. × P. alba L. inoculated with compatible and incompetent isolates of Paxillus involutus (Batsch Fr. was investigated. Screening of the ectomycorrhizal fungal isolates was initiated with exploration of mycelial growth characteristics and mycorrhizal ability in vitro with poplar. Both traits varied within the fungus although they did not seem to be genetically correlated. While isolates SCO1, NAU, and 031 grew faster than others, only isolates MAJ, SCO1, and 031 were able to form ectomycorrhiza with poplar. Isolates MAJ (compatible and NAU (incompetent were subsequently selected for further experiments. Activity of peroxidase, one of the defense-related enzymes, was examined in pure culture and short root components of compatible and incompetent interactions between poplar and P. involutus. Peroxidase activities increased significantly in poplar inoculated with incompetent isolate of the fungus compared to control, while induction of the same enzyme was not detected in compatible associations.

  16. Discovery and validation of a colorectal cancer classifier in a new blood test with improved performance for high-risk subjects

    DEFF Research Database (Denmark)

    Croner, Lisa J; Dillon, Roslyn; Kao, Athit

    2017-01-01

    BACKGROUND: The aim was to improve upon an existing blood-based colorectal cancer (CRC) test directed to high-risk symptomatic patients, by developing a new CRC classifier to be used with a new test embodiment. The new test uses a robust assay format-electrochemiluminescence immunoassays......, the indeterminate rate of the new panel was 23.2%, sensitivity/specificity was 0.80/0.83, PPV was 36.5%, and NPV was 97.1%. CONCLUSIONS: The validated classifier serves as the basis of a new blood-based CRC test for symptomatic patients. The improved performance, resulting from robust concentration measures across......-to quantify protein concentrations. The aim was achieved by building and validating a CRC classifier using concentration measures from a large sample set representing a true intent-to-test (ITT) symptomatic population. METHODS: 4435 patient samples were drawn from the Endoscopy II sample set. Samples were...

  17. Pointing Hand Stimuli Induce Spatial Compatibility Effects and Effector Priming

    Directory of Open Access Journals (Sweden)

    Akio eNishimura

    2013-04-01

    Full Text Available The present study investigated the automatic influence of perceiving a picture that indicates other’s action on one’s own task performance in terms of spatial compatibility and effector priming. Participants pressed left and right buttons with their left and right hands respectively, depending on the color of a central dot target. Preceding the target, a left or right hand stimulus (pointing either to the left or right with the index or little finger was presented. In Experiment 1, with brief presentation of the pointing hand, a spatial compatibility effect was observed: Responses were faster when the direction of the pointed finger and the response position were spatially congruent than when incongruent. The spatial compatibility effect was larger for the pointing index finger stimulus compared to the pointing little finger stimulus. Experiment 2 employed longer duration of the pointing hand stimuli. In addition to the spatial compatibility effect for the pointing index finger, the effector priming effect was observed: Responses were faster when the anatomical left/right identity of the pointing and response hands matched than when the pointing and response hands differed in left/right identity. The results indicate that with sufficient processing time, both spatial/symbolic and anatomical features of a static body part implying another’s action simultaneously influence different aspects of the perceiver’s own action. Hierarchical coding, according to which an anatomical code is used only when a spatial code is unavailable, may not be applicable if stimuli as well as responses contain anatomical features.

  18. Design of a New MR Compatible Haptic Interface with Six Actuated Degrees of Freedom

    DEFF Research Database (Denmark)

    Ergin, Mehmet Alper; Kühne, Markus; Thielscher, Axel

    2014-01-01

    Functional magnetic resonance imaging is an often adopted tool to study human motor control mechanisms. Highly controlled experiments as required by this form of analysis can be realized with haptic interfaces. Their design is challenging because of strong safety and MR compatibility requirements....... Existing MR-compatible haptic interfaces are restricted to maximum three actuated degrees of freedom. We propose an MR-compatible haptic interface with six actuated degrees of freedom to be able to study human brain mechanisms of natural pick-and-place movements including arm transport. In this work, we...... present its mechanical design, kinematic and dynamic model, as well as report on its model-based characterization. A novel hybrid control scheme for the employed ultrasonic motors is introduced. Preliminary MR compatibility tests based on one complete actuator-sensor module are performed. No measurable...

  19. A case of coombs-positive severe late anemia without hyperbilirubinemia, refractory to blood transfusion, improved with immunoglobulin

    Directory of Open Access Journals (Sweden)

    Supriya Kushwah

    2017-01-01

    Full Text Available Rhesus hemolytic disease of newborn is a well-known disease with early and late complications mainly manifesting as severe hyperbilirubinemia requiring prompt treatment such as exchange transfusion and immunoglobulins. We report a case of Coombs-positive severe late anemia without hyperbilirubinemia which presented with features such as sepsis and failure to gain weight. Baby was refractory to blood transfusion initially, but later on successfully improved with immunoglobulins.

  20. Electromagnetic Compatibility of Matrix Converter System

    Directory of Open Access Journals (Sweden)

    S. Fligl

    2006-12-01

    Full Text Available The presented paper deals with matrix converters pulse width modulation strategies design with emphasis on the electromagnetic compatibility. Matrix converters provide an all-silicon solution to the problem of converting AC power from one frequency to another, offering almost all the features required of an ideal static frequency changer. They possess many advantages compared to the conventional voltage or current source inverters. A matrix converter does not require energy storage components as a bulky capacitor or an inductance in the DC-link, and enables the bi-directional power flow between the power supply and load. The most of the contemporary modulation strategies are able to provide practically sinusoidal waveforms of the input and output currents with negligible low order harmonics, and to control the input displacement factor. The perspective of matrix converters regarding EMC in comparison with other types of converters is brightly evident because it is no need to use any equipment for power factor correction and current and voltage harmonics reduction. Such converter with proper control is properly compatible both with the supply mains and with the supplied load. A special digital control system was developed for the realized experimental test bed which makes it possible to achieve greater throughput of the digital control system and its variability.