WorldWideScience

Sample records for improved diagnostic evaluation

  1. Improving early cycle economic evaluation of diagnostic technologies.

    Science.gov (United States)

    Steuten, Lotte M G; Ramsey, Scott D

    2014-08-01

    The rapidly increasing range and expense of new diagnostics, compels consideration of a different, more proactive approach to health economic evaluation of diagnostic technologies. Early cycle economic evaluation is a decision analytic approach to evaluate technologies in development so as to increase the return on investment as well as patient and societal impact. This paper describes examples of 'early cycle economic evaluations' as applied to diagnostic technologies and highlights challenges in its real-time application. It shows that especially in the field of diagnostics, with rapid technological developments and a changing regulatory climate, early cycle economic evaluation can have a guiding role to improve the efficiency of the diagnostics innovation process. In the next five years the attention will move beyond the methodological and analytic challenges of early cycle economic evaluation towards the challenge of effectively applying it to improve diagnostic research and development and patient value. Future work in this area should therefore be 'strong on principles and soft on metrics', that is, the metrics that resonate most clearly with the various decision makers in this field.

  2. Improving early cycle economic evaluation of diagnostic technologies

    NARCIS (Netherlands)

    Steuten, Lotte Maria Gertruda; Ramsey, Scott D.

    2014-01-01

    The rapidly increasing range and expense of new diagnostics, compels consideration of a different, more proactive approach to health economic evaluation of diagnostic technologies. Early cycle economic evaluation is a decision analytic approach to evaluate technologies in development so as to

  3. Measures to Improve Diagnostic Safety in Clinical Practice.

    Science.gov (United States)

    Singh, Hardeep; Graber, Mark L; Hofer, Timothy P

    2016-10-20

    Timely and accurate diagnosis is foundational to good clinical practice and an essential first step to achieving optimal patient outcomes. However, a recent Institute of Medicine report concluded that most of us will experience at least one diagnostic error in our lifetime. The report argues for efforts to improve the reliability of the diagnostic process through better measurement of diagnostic performance. The diagnostic process is a dynamic team-based activity that involves uncertainty, plays out over time, and requires effective communication and collaboration among multiple clinicians, diagnostic services, and the patient. Thus, it poses special challenges for measurement. In this paper, we discuss how the need to develop measures to improve diagnostic performance could move forward at a time when the scientific foundation needed to inform measurement is still evolving. We highlight challenges and opportunities for developing potential measures of "diagnostic safety" related to clinical diagnostic errors and associated preventable diagnostic harm. In doing so, we propose a starter set of measurement concepts for initial consideration that seem reasonably related to diagnostic safety and call for these to be studied and further refined. This would enable safe diagnosis to become an organizational priority and facilitate quality improvement. Health-care systems should consider measurement and evaluation of diagnostic performance as essential to timely and accurate diagnosis and to the reduction of preventable diagnostic harm.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  4. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  5. Improving diagnostic sensitivity of combined dermoscopy and reflectance confocal microscopy imaging through double reader concordance evaluation in telemedicine settings: A retrospective study of 1000 equivocal cases.

    Directory of Open Access Journals (Sweden)

    A M Witkowski

    Full Text Available Reflectance confocal microscopy (RCM is an imaging device that permits non-invasive visualization of cellular morphology and has been shown to improve diagnostic accuracy of dermoscopically equivocal cutaneous lesions. The application of double reader concordance evaluation of dermoscopy-RCM image sets in retrospective settings and its potential application to telemedicine evaluation has not been tested in a large study population.To improve diagnostic sensitivity of RCM image diagnosis using a double reader concordance evaluation approach; to reduce mismanagement of equivocal cutaneous lesions in retrospective consultation and telemedicine settings.1000 combined dermoscopy-RCM image sets were evaluated in blind by 10 readers with advanced training and internship in dermoscopy and RCM evaluation. We compared sensitivity and specificity of single reader evaluation versus double reader concordance evaluation as well as the effect of diagnostic confidence on lesion management in a retrospective setting.Single reader evaluation resulted in an overall sensitivity of 95.2% and specificity of 76.3%, with misdiagnosis of 8 melanomas, 4 basal cell carcinomas and 2 squamous cell carcinomas. Combined double reader evaluation resulted in an overall sensitivity of 98.3% and specificity of 65.5%, with misdiagnosis of 1 in-situ melanoma and 2 basal cell carcinomas.Evaluation of dermoscopy-RCM image sets of cutaneous lesions by single reader evaluation in retrospective settings is limited by sensitivity levels that may result in potential mismanagement of malignant lesions. Double reader blind concordance evaluation may improve the sensitivity of diagnosis and management safety. The use of a second check can be implemented in telemedicine settings where expert consultation and second opinions may be required.

  6. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...... characteristics fitted with their own priorities. Goodness of fit of mRDTs with existing consultation and diagnostic practices appeared crucial to maximising the impact of mRDTs on care, as did prior familiarity with malaria testing; adequate human resources and supplies; possible alternative treatments for m...

  7. Improvement of malaria diagnostic system based on acridine orange staining.

    Science.gov (United States)

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  8. Water chemistry data acquisition, processing, evaluation and diagnostic systems in Light Water Reactors: Future improvement of plant reliability and safety

    International Nuclear Information System (INIS)

    Uchida, S.; Takiguchi, H.; Ishigure, K.

    2006-01-01

    Data acquisition, processing and evaluation systems have been applied in major Japanese PWRs and BWRs to provide (1) reliable and quick data acquisition with manpower savings in plant chemical laboratories and (2) smooth and reliable information transfer among chemists, plant operators, and supervisors. Data acquisition systems in plants consist of automatic and semi-automatic instruments for chemical analyses, e. g., X-ray fluorescence analysis and ion chromatography, while data processing systems consist of PC base-sub-systems, e.g., data storage, reliability evaluation, clear display, and document preparation for understanding the plant own water chemistry trends. Precise and reliable evaluations of water chemistry data are required in order to improve plant reliability and safety. For this, quality assurance of the water chemistry data acquisition system is needed. At the same time, theoretical models are being applied to bridge the gaps between measured water chemistry data and the information desired to understand the interaction of materials and cooling water in plants. Major models which have already been applied for plant evaluation are: (1) water radiolysis models for BWRs and PWRs; (2) crevice radiolysis model for SCC in BWRs; and (3) crevice pH model for SG tubing in PWRs. High temperature water chemistry sensors and automatic plant diagnostic systems have been applied in only restricted areas. ECP sensors are gaining popularity as tools to determine the effects of hydrogen injection in BWR systems. Automatic plant diagnostic systems based on artificial intelligence will be more popular after having sufficient experience with off line diagnostic systems. (author)

  9. Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.

    Science.gov (United States)

    Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep

    2018-04-20

    Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.

  10. Improving the diagnostic performance of lung scintigraphy in suspected pulmonary embolic disease

    International Nuclear Information System (INIS)

    Gleeson, F.V.; Turner, S.; Scarsbrook, A.F.

    2006-01-01

    Aim: to determine the effectiveness of a new imaging algorithm in the investigation of suspected pulmonary embolism (PE). Materials and methods: A new imaging algorithm for suspected PE was introduced following the installation of a multisection computed tomography (CT) machine at our institution. Before its installation, patients with suspected PE were evaluated with ventilation/perfusion (V/Q) scintigraphy. Subsequently, patients were triaged according to chest radiography (CR) and respiratory history to either lung scintigraphy or CT pulmonary angiography (CTPA). Patients with a normal CR and no history of lung disease were evaluated using perfusion (Q) scintigraphy [ventilation (V) scintigraphy was no longer performed]. Patients with an abnormal CR, asthma or chronic lung disease were evaluated using CTPA. All V/Q images in a continuous 3-year period before the introduction of the new imaging algorithm and all Q images performed in a 3-year period after its introduction were retrospectively reviewed. Imaging reports were categorized into normal, non-diagnostic (low or intermediate probability) or high probability for PE. Patients in the later group who subsequently underwent CTPA, were also reviewed. Results: After the policy change the percentage of normal scintigrams significantly increased (39 to 60%; p < 0.001). There was a non-significant increase in the percentage of high probability scintigrams (15 to 18%; p = 0.716). Overall the diagnostic yield of lung scintigraphy improved significantly (54 to 78%; p < 0.001). Conclusion: the diagnostic performance of lung scintigraphy can be improved by careful triage of patients to either Q scintigraphy or CTPA based on clinical history and CR findings. Q scintigraphy remains a valuable diagnostic test in the investigation of suspected PE in carefully selected patients

  11. User interface graphically improves generator AL diagnostics

    International Nuclear Information System (INIS)

    Gray, R.F.; King, I.J.

    1991-01-01

    In April of 1990, the recently developed Diagnostic Graphical User Interface (DGUI) was installed at a large nuclear power plant in the midwestern United States. Since 1988, the power plant has been using the Generator Artificial Intelligence Diagnostics (GenAID) System, which provides online diagnostic capability for the generator and generator auxiliaries through a plant data center (PDC) and communication link to the diagnostic operations center (DOC) in Orlando, Florida. The enhanced system provides the power plant control room operator with a comprehensive tool to understand and better utilize the information provided by the existing knowledge bases. This paper represents a significant improvement over existing technology by providing the power plant control room operator with the capability of interacting directly with the diagnostic system

  12. Carotid artery dissection on non-contrast CT: Does color improve the diagnostic confidence?

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca, E-mail: lucasaba@tiscali.it [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Argiolas, Giovanni Maria [Department of Radiology, Azienda Ospedaliero Brotzu (A.O.B.), di Cagliari, Cagliari 09100 (Italy); Raz, Eytan [Department of Radiology, New York University School of Medicine, New York (United States); Department of Neurology and Psychiatry, Sapienza University of Rome (Italy); Sannia, Stefano [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Suri, Jasjit S. [Diagnostic and Monitoring Division, AtheroPointTM LLC, Roseville, CA (United States); Electrical Engineering Department (Aff.), Idaho State University, ID (United States); Siotto, Paolo [Department of Radiology, Azienda Ospedaliero Brotzu (A.O.B.), di Cagliari, Cagliari 09100 (Italy); Sanfilippo, Roberto; Montisci, Roberto [Department of Vascular Surgery, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Piga, Mario [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari – Polo di Monserrato, s.s. 554 Monserrato, Cagliari 09045 (Italy); Wintermark, Max [Department of Radiology, Neuroradiology Division, University of Virginia, Box 800170, Charlottesville, VA, 22908 (United States)

    2014-12-15

    Highlights: • The use of a color scale to display the non-contrast CT images in lieu of the classic grayscale improves the diagnostic confidence of the readers. • Radiologists should consider the use of a color scale, rather than the conventional grayscale, to assess non-contrast CT studies for possible carotid artery dissection. - Abstract: Purpose: The purpose of this work was to evaluate if the use of color maps, instead of conventional grayscale images, would improve the observer's diagnostic confidence in the non-contrast CT evaluation of internal carotid artery dissection (ICAD). Materials and methods: One hundred patients (61 men, 39 women; mean age, 51 years; range, 25–78 years), 40 with and 60 without ICAD, underwent non-contrast CT and were included in this the retrospective study. In this study, three groups of patients were considered: patients with MR confirmation of ICAD, n = 40; patients with MR confirmation of ICAD absence, n = 20; patients who underwent CT of the carotid arteries because of atherosclerotic disease, n = 40. Four blinded observers with different levels of expertise (expert, intermediate A, intermediate B and trainee) analyzed the non-contrast CT datasets using a cross model (one case grayscale and the following case using the color scale). The presence of ICAD was scored on a 5-point scale in order to assess the observer's diagnostic confidence. After 3 months the four observers evaluated the same datasets by using the same cross-model for the alternate readings (one case color scale and the following case using the grayscale). Statistical analysis included receiver operating characteristics (ROC) curve analysis, the Cohen weighted test and sensitivity, specificity, PPV, NPV, accuracy, LR+ and LR−. Results: The ROC curve analysis showed that, for all observers, the use of color scale resulted in an improved diagnostic confidence with AUC values increasing from 0.896 to 0.936, 0.823 to 0.849, 0.84 to 0.909 and 0

  13. Evaluating online diagnostic decision support tools for the clinical setting.

    Science.gov (United States)

    Pryor, Marie; White, David; Potter, Bronwyn; Traill, Roger

    2012-01-01

    Clinical decision support tools available at the point of care are an effective adjunct to support clinicians to make clinical decisions and improve patient outcomes. We developed a methodology and applied it to evaluate commercially available online clinical diagnostic decision support (DDS) tools for use at the point of care. We identified 11 commercially available DDS tools and assessed these against an evaluation instrument that included 6 categories; general information, content, quality control, search, clinical results and other features. We developed diagnostically challenging clinical case scenarios based on real patient experience that were commonly missed by junior medical staff. The evaluation was divided into 2 phases; an initial evaluation of all identified and accessible DDS tools conducted by the Clinical Information Access Portal (CIAP) team and a second phase that further assessed the top 3 tools identified in the initial evaluation phase. An evaluation panel consisting of senior and junior medical clinicians from NSW Health conducted the second phase. Of the eleven tools that were assessed against the evaluation instrument only 4 tools completely met the DDS definition that was adopted for this evaluation and were able to produce a differential diagnosis. From the initial phase of the evaluation 4 DDS tools scored 70% or more (maximum score 96%) for the content category, 8 tools scored 65% or more (maximum 100%) for the quality control category, 5 tools scored 65% or more (maximum 94%) for the search category, and 4 tools score 70% or more (maximum 81%) for the clinical results category. The second phase of the evaluation was focused on assessing diagnostic accuracy for the top 3 tools identified in the initial phase. Best Practice ranked highest overall against the 6 clinical case scenarios used. Overall the differentiating factor between the top 3 DDS tools was determined by diagnostic accuracy ranking, ease of use and the confidence and

  14. Development of an Adaptable Display and Diagnostic System for the Evaluation of Tropical Cyclone Forecasts

    Science.gov (United States)

    Kucera, P. A.; Burek, T.; Halley-Gotway, J.

    2015-12-01

    NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.

  15. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  16. Improving patient care through molecular diagnostics

    NARCIS (Netherlands)

    Perez, Edith A.; Pusztai, Lajos; van de Vijver, Marc

    2004-01-01

    Traditional cancer diagnostic techniques include assessment of histologic appearance, identification of specific tumor subtypes, tumor grading, assessment of lymph node status, and presence of metastasis. These are useful for initial evaluation, but are limited in their ability to predict response

  17. Evaluation of radiation protection in nuclear medicine diagnostic procedures

    International Nuclear Information System (INIS)

    Mohammed, Ezzeldien Mohammed Nour

    2013-05-01

    This study conducted to evaluate the radiation protection in nuclear medicine diagnostic procedures in four nuclear medicine departments in Sudan. The evaluated procedures followed in these departments were in accordance with the standards, International Recommendations and code of practice for radiation protection in nuclear medicine. The evolution included the optimum design for diagnostic nuclear medicine departments, dealing with radioactive sources, quality assurance and quality control, training and responsibilities for radiation worker taking into account economic factors in Sudan. Evaluation of radiation protection procedures in diagnostic investigations was carried out by taken direct measurements of dose rate and the contamination level in some areas where radiation sources, radiation workers and public are involved. Designated questionnaires covered thirteen areas of radiation protection based on inspection check list for nuclear medicine prepared by the International Atomic Energy Agency (IAEA) and American Association of Physicist in Medicine (AAPM) were used in the evaluation. This questionnaire has been Filled by Radiation Protection Officer (RPO), nuclear medicine technologist, nuclear medicine specialist in the nuclear medicine departments. Four hospitals, two governmental hospital and two private hospitals, have been assisted, the assessment shows that although the diagnostic nuclear medicine department in Sudan are not applying a fully safety and radiation protection procedures, but the level of radiation dose and the contamination level were found within acceptable limits. The private hospital D scored the higher level of protection (85.25%) while the governmental hospital C scored the lower level of protection (59.02%). Finally, this study stated some recommendations that if implemented could improve the level of radiation protection in nuclear medicine department. One of the most important recommendations is that a proper radiation protection

  18. Action Research to Improve the Learning Space for Diagnostic Techniques

    Directory of Open Access Journals (Sweden)

    Ellen Ariel

    2015-08-01

    Full Text Available The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of “knowledge” and “understanding.” The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001, it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed.

  19. Action Research to Improve the Learning Space for Diagnostic Techniques.

    Science.gov (United States)

    Ariel, Ellen; Owens, Leigh

    2015-12-01

    The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of "knowledge" and "understanding." The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001), it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed. Journal of Microbiology & Biology Education.

  20. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  1. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    International Nuclear Information System (INIS)

    Arimizu, Noboru

    1980-01-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for vesectable small cancers was investigated by the project team and coworkers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared. (Tsunoda, M.)

  2. Improvement of diagnostic accuracy, and clinical evaluation of computed tomography and ultrasonography for deep seated cancers

    Energy Technology Data Exchange (ETDEWEB)

    Arimizu, N [Chiba Univ. (Japan). School of Medicine

    1980-06-01

    Cancers of the liver, gallbladder, and pancreas which were difficult to be detected at an early stage were studied. Diagnostic accuracy of CT and ultrasonography for resectable small cancers was investigated by the project team and co-workers. Only a few cases of hepatocellular carcinoma, cancer of the common bile duct, and cancer of the pancreas head, with the maximum diameter of 1 - 2 cm, were able to be diagnosed by CT. There seemed to be more false negative cases with small cancers of that size. The limit of the size which could be detected by CT was thought to be 2 - 3 cm. Similar results were obtained by ultrasonography. Cancer of the pancreas body with the maximum diameter of less than 3.5 cm could not be detected by both CT and ultrasonography. Diagnostic accuracy of CT for liver cancer was improved by selective intraarterial injection of contrast medium. Improvement of the quality of ultrasonograms was achieved through this study. Merits and demerits of CT and ultrasonography were also compared.

  3. Evaluation of two-beam spectroscopy as a plasma diagnostic

    International Nuclear Information System (INIS)

    Billard, B.D.

    1980-04-01

    A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler

  4. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    Science.gov (United States)

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  5. The Diagnostic Utility of Midcarpal Anesthetic Injection in the Evaluation of Chronic Wrist Pain

    OpenAIRE

    Bell, S. Josh; Hofmeister, Eric P.; Moran, Steven L.; Shin, Alexander Y.

    2007-01-01

    The evaluation of chronic wrist pain can be a diagnostic dilemma. Lidocaine injections combined with corticosteroids are often used for both diagnosis and therapy. The purpose of this study was to determine if a midcarpal injection of lidocaine could serve as a diagnostic tool in patients with chronic wrist pain. Specifically, the relationship of pain relief from the injection and improvement of grip strength were compared to the presence of intracarpal pathology as confirmed by wrist arthros...

  6. Better Tests, Better Care: Improved Diagnostics for Infectious Diseases

    Science.gov (United States)

    Caliendo, Angela M.; Gilbert, David N.; Ginocchio, Christine C.; Hanson, Kimberly E.; May, Larissa; Quinn, Thomas C.; Tenover, Fred C.; Alland, David; Blaschke, Anne J.; Bonomo, Robert A.; Carroll, Karen C.; Ferraro, Mary Jane; Hirschhorn, Lisa R.; Joseph, W. Patrick; Karchmer, Tobi; MacIntyre, Ann T.; Reller, L. Barth; Jackson, Audrey F.

    2013-01-01

    In this IDSA policy paper, we review the current diagnostic landscape, including unmet needs and emerging technologies, and assess the challenges to the development and clinical integration of improved tests. To fulfill the promise of emerging diagnostics, IDSA presents recommendations that address a host of identified barriers. Achieving these goals will require the engagement and coordination of a number of stakeholders, including Congress, funding and regulatory bodies, public health agencies, the diagnostics industry, healthcare systems, professional societies, and individual clinicians. PMID:24200831

  7. Improving on the diagnostic characteristics of echocardiography for pulmonary hypertension.

    Science.gov (United States)

    Broderick-Forsgren, Kathleen; Davenport, Clemontina A; Sivak, Joseph A; Hargett, Charles William; Foster, Michael C; Monteagudo, Andrew; Armour, Alicia; Rajagopal, Sudarshan; Arges, Kristine; Velazquez, Eric J; Samad, Zainab

    2017-09-01

    This retrospective study evaluated the diagnostic characteristics of a combination of echocardiographic parameters for pulmonary hypertension (PH). Right ventricular systolic pressure (RVSP) estimation by echocardiography (echo) is used to screen for PH. However, the sensitivity of this method is suboptimal. We hypothesized that RVSP estimation in conjunction with other echo parameters would improve the value of echo for PH. The Duke Echo database was queried for adult patients with known or suspected PH who had undergone both echo and right heart catheterization (RHC) within a 24 h period between 1/1/2008 and 12/31/2013. Patients with complex congenital heart disease, heart transplantation, ventricular assist device, or on mechanical ventilation at time of study were excluded. Diagnostic characteristics of several echo parameters (right atrial enlargement, pulmonary artery (PA) enlargement, RV enlargement, RV dysfunction, and RVSP) for PH (mean PA pressure 25 mmHg on RHC) were evaluated among 1007 patients. RVSP ≥40 had a sensitivity of 77% (accuracy 77), while RVSP ≥35 had the highest sensitivity at 88% (81% accuracy). PA enlargement had the lowest sensitivity at 17%. The area under the curve (AUC) for RVSP was 0.844. A model including RVSP, RA, PA, RV enlargement and RV dysfunction had a higher AUC (AUC = 0.87) than RVSP alone. The value of echo as a screening test for PH is improved by a model incorporating a lower RVSP in addition to other right heart parameters. These findings need to be validated in prospective cohorts.

  8. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2011-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  9. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2010-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  10. Tracking Progress in Improving Diagnosis: A Framework for Defining Undesirable Diagnostic Events.

    Science.gov (United States)

    Olson, Andrew P J; Graber, Mark L; Singh, Hardeep

    2018-01-29

    Diagnostic error is a prevalent, harmful, and costly phenomenon. Multiple national health care and governmental organizations have recently identified the need to improve diagnostic safety as a high priority. A major barrier, however, is the lack of standardized, reliable methods for measuring diagnostic safety. Given the absence of reliable and valid measures for diagnostic errors, we need methods to help establish some type of baseline diagnostic performance across health systems, as well as to enable researchers and health systems to determine the impact of interventions for improving the diagnostic process. Multiple approaches have been suggested but none widely adopted. We propose a new framework for identifying "undesirable diagnostic events" (UDEs) that health systems, professional organizations, and researchers could further define and develop to enable standardized measurement and reporting related to diagnostic safety. We propose an outline for UDEs that identifies both conditions prone to diagnostic error and the contexts of care in which these errors are likely to occur. Refinement and adoption of this framework across health systems can facilitate standardized measurement and reporting of diagnostic safety.

  11. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE's nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer

  12. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  13. Microfluidic Purification and Concentration of Malignant Pleural Effusions for Improved Molecular and Cytomorphological Diagnostics

    Science.gov (United States)

    Go, Derek E.; Talati, Ish; Ying, Yong; Rao, Jianyu; Kulkarni, Rajan P.; Di Carlo, Dino

    2013-01-01

    Evaluation of pleural fluids for metastatic cells is a key component of diagnostic cytopathology. However, a large background of smaller leukocytes and/or erythrocytes can make accurate diagnosis difficult and reduce specificity in identification of mutations of interest for targeted anti-cancer therapies. Here, we describe an automated microfluidic system (Centrifuge Chip) which employs microscale vortices for the size-based isolation and concentration of cancer cells and mesothelial cells from a background of blood cells. We are able to process non-diluted pleural fluids at 6 mL/min and enrich target cells significantly over the background; we achieved improved purity in all patient samples analyzed. The resulting isolated and viable cells are readily available for immunostaining, cytological analysis, and detection of gene mutations. To demonstrate the utility towards aiding companion diagnostics, we also show improved detection accuracy of KRAS gene mutations in lung cancer cells processed using the Centrifuge Chip, leading to an increase in the area under the curve (AUC) of the receiver operating characteristic from 0.90 to 0.99. The Centrifuge Chip allows for rapid concentration and processing of large volumes of bodily fluid samples for improved cytological diagnosis and purification of cells of interest for genetic testing, which will be helpful for enhancing diagnostic accuracy. PMID:24205153

  14. Development of the Model of the System of Managerial Diagnostics of the Enterprise on the Basis of Improvement of Diagnostic Purposes

    Directory of Open Access Journals (Sweden)

    Grzegorz Pawlowski

    2017-11-01

    Full Text Available The purpose of the article is to develop a model of the system of managerial diagnostics of the enterprise on the basis of the improvement of diagnostic purposes. The developed model of the system of managerial diagnostics of the enterprise is a set of subjects (owners, managers, investors, specialists, etc., objects (management system, resources, technology, methods (a set of methods and means, business indicators and criteria (parameters that, when interacting, provide the achievement (efficient and effective of the diagnostic objectives of the system of the objectives of managerial diagnostics of the enterprise, taking into account the compliance of its competitive strategy of the state of the environment function of direct action (competitors, customers, suppliers, mediators, and other contact audiences in the context of improving the efficiency and developing the management. It is determined that the system of goals of the model of the system of managerial diagnostics of the enterprise (taking into account the ensuring of the compliance of the system of management with strategic goals and tactical tasks form the following key diagnostic objectives that require improvement on the basis of business indicators (parameters, namely: 1 diagnostics of the effectiveness of controlling the internal business processes of the enterprise; 2 diagnostics of the effectiveness of the typical organizational structure of enterprise management; 3 diagnostics of the efficiency of standardization of the work of linear and functional managers and specialists at the enterprise; 4 diagnostics of the enterprise in the areas of vocational education, labor activity and motivation, innovation work and social development; 5 diagnostics of the level of conflict in the team at the enterprise; 6 diagnostics of efficiency of use of information technologies in the management of the enterprise. The prospect of further research in this area is to improve the complex system of

  15. Quality of dementia diagnostic evaluation for ethnic minority patients: a nationwide study

    DEFF Research Database (Denmark)

    Nielsen, T Rune; Andersen, Birgitte Bo; Kastrup, Marianne

    2011-01-01

    Background/Aims: Diagnostic evaluation of dementia for ethnic minority patients may be challenging. This study aimed to evaluate the quality of diagnostic evaluation of dementia for patients from ethnic minorities in Denmark. Methods: The Danish national hospital registers were used to identify p......: There are significant ethnic disparities in the quality of diagnostic evaluations and outcome of dementia in the secondary healthcare sector....

  16. Elimination of pain improves specificity of clinical diagnostic criteria for adult chronic rhinosinusitis.

    Science.gov (United States)

    Hirsch, Scott D; Reiter, Evan R; DiNardo, Laurence J; Wan, Wen; Schuman, Theodore A

    2017-05-01

    Determine whether the elimination of pain improves accuracy of clinical diagnostic criteria for adult chronic rhinosinusitis. Retrospective cohort study. History, symptoms, nasal endoscopy, and computed tomography (CT) results were analyzed for 1,186 adults referred to an academic otolaryngology clinic with presumptive diagnosis of chronic rhinosinusitis. Clinical diagnosis was rendered using the 1997 Rhinosinusitis Taskforce (RSTF) Guidelines and a modified version eliminating facial pain, ear pain, dental pain, and headache. Four hundred seventy-nine subjects (40%) met inclusion criteria. Among subjects positive by RSTF guidelines, 45% lacked objective evidence of sinonasal inflammation by CT, 48% by endoscopy, and 34% by either modality. Applying modified RSTF diagnostic criteria, 39% lacked sinonasal inflammation by CT, 38% by endoscopy, and 24% by either modality. Using either abnormal CT or endoscopy as the reference standard, modified diagnostic criteria yielded a statistically significant increase in specificity from 37.1% to 65.1%, with a nonsignificant decrease in sensitivity from 79.2% to 70.3%. Analysis of comorbidities revealed temporomandibular joint disorder, chronic cervical pain, depression/anxiety, and psychiatric medication use to be negatively associated with objective inflammation on CT or endoscopy. Clinical diagnostic criteria overestimate the prevalence of chronic rhinosinusitis. Removing facial pain, ear pain, dental pain, and headache increased specificity without a concordant loss in sensitivity. Given the high prevalence of sinusitis, improved clinical diagnostic criteria may assist primary care providers in more accurately predicting the presence of inflammation, thereby reducing inappropriate antibiotic use or delayed referral for evaluation of primary headache syndromes. 4. Laryngoscope, 127:1011-1016, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Uncertainty during breast diagnostic evaluation: state of the science.

    Science.gov (United States)

    Montgomery, Mariann

    2010-01-01

    To present the state of the science on uncertainty in relationship to the experiences of women undergoing diagnostic evaluation for suspected breast cancer. Published articles from Medline, CINAHL, PubMED, and PsycINFO from 1983-2008 using the following key words: breast biopsy, mammography, uncertainty, reframing, inner strength, and disruption. Fifty research studies were examined with all reporting the presence of anxiety persisting throughout the diagnostic evaluation until certitude is achieved through the establishment of a definitive diagnosis. Indirect determinants of uncertainty for women undergoing breast diagnostic evaluation include measures of anxiety, depression, social support, emotional responses, defense mechanisms, and the psychological impact of events. Understanding and influencing the uncertainty experience have been suggested to be key in relieving psychosocial distress and positively influencing future screening behaviors. Several studies examine correlational relationships among anxiety, selection of coping methods, and demographic factors that influence uncertainty. A gap exists in the literature with regard to the relationship of inner strength and uncertainty. Nurses can be invaluable in assisting women in coping with the uncertainty experience by providing positive communication and support. Nursing interventions should be designed and tested for their effects on uncertainty experienced by women undergoing a breast diagnostic evaluation.

  18. Decision making in trauma settings: simulation to improve diagnostic skills.

    Science.gov (United States)

    Murray, David J; Freeman, Brad D; Boulet, John R; Woodhouse, Julie; Fehr, James J; Klingensmith, Mary E

    2015-06-01

    In the setting of acute injury, a wrong, missed, or delayed diagnosis can impact survival. Clinicians rely on pattern recognition and heuristics to rapidly assess injuries, but an overreliance on these approaches can result in a diagnostic error. Simulation has been advocated as a method for practitioners to learn how to recognize the limitations of heuristics and develop better diagnostic skills. The objective of this study was to determine whether simulation could be used to provide teams the experiences in managing scenarios that require the use of heuristic as well as analytic diagnostic skills to effectively recognize and treat potentially life-threatening injuries. Ten scenarios were developed to assess the ability of trauma teams to provide initial care to a severely injured patient. Seven standard scenarios simulated severe injuries that once diagnosed could be effectively treated using standard Advanced Trauma Life Support algorithms. Because diagnostic error occurs more commonly in complex clinical settings, 3 complex scenarios required teams to use more advanced diagnostic skills to uncover a coexisting condition and treat the patient. Teams composed of 3 to 5 practitioners were evaluated in the performance of 7 (of 10) randomly selected scenarios (5 standard, 2 complex). Expert rates scored teams using standardized checklists and global scores. Eighty-three surgery, emergency medicine, and anesthesia residents constituted 21 teams. Expert raters were able to reliably score the scenarios. Teams accomplished fewer checklist actions and received lower global scores on the 3 analytic scenarios (73.8% [12.3%] and 5.9 [1.6], respectively) compared with the 7 heuristic scenarios (83.2% [11.7%] and 6.6 [1.3], respectively; P heuristic scenarios but were less effective when managing the scenarios that require a more analytic approach. Simulation can be used to provide teams with decision-making experiences in trauma settings and could be used to improve

  19. DIAGNOSTIC AND PROPOSAL OF IMPROVEMENT FOR THE INNOVATION MANAGEMENT IN A TECHNOLOGICAL COMPANY

    Directory of Open Access Journals (Sweden)

    Rossetti, Germán

    2017-12-01

    Full Text Available The Innovation Management is defined as the process oriented to organize and lead available resources, both technical and economic, with the objective of increasing the creation of new products, processes, knowledge and their application in the structure of the company. Nowadays companies are immersed in a globalized world, where competition is higher, which implies their growing interest in innovating, developing and improving their products or services to take a leading position in the market. Therefore, it is essential to be at the vanguard of current needs and to use certain tools that help to offer better products or services, and to obtain higher benefits, economic and social, technological, prestige, among others. In this paper a diagnostic and proposal of improvement for the Innovation Management in a technology-based company, located in the province of Santa Fe, Argentina, is made. For this, a methodology that allows to evaluate the capacity to innovate of the company is applied. As a main conclusion, it can be said that the diagnostic and proposal of improvement provided to the company is the starting point to ensure a successful and continuous innovation management.

  20. Evaluating Secondary Students' Scientific Reasoning in Genetics Using a Two-Tier Diagnostic Instrument

    Science.gov (United States)

    Tsui, Chi-Yan; Treagust, David

    2010-05-01

    While genetics has remained as one key topic in school science, it continues to be conceptually and linguistically difficult for students with the concomitant debates as to what should be taught in the age of biotechnology. This article documents the development and implementation of a two-tier multiple-choice instrument for diagnosing grades 10 and 12 students' understanding of genetics in terms of reasoning. The pretest and posttest forms of the diagnostic instrument were used alongside other methods in evaluating students' understanding of genetics in a case-based qualitative study on teaching and learning with multiple representations in three Western Australian secondary schools. Previous studies have shown that a two-tier diagnostic instrument is useful in probing students' understanding or misunderstanding of scientific concepts and ideas. The diagnostic instrument in this study was designed and then progressively refined, improved, and implemented to evaluate student understanding of genetics in three case schools. The final version of the instrument had Cronbach's alpha reliability of 0.75 and 0.64, respectively, for its pretest and the posttest forms when it was administered to a group of grade 12 students (n = 17). This two-tier diagnostic instrument complemented other qualitative data collection methods in this research in generating a more holistic picture of student conceptual learning of genetics in terms of scientific reasoning. Implications of the findings of this study using the diagnostic instrument are discussed.

  1. Magnetic resonance imaging for diagnostic evaluation of hernia of an invertebral disk

    International Nuclear Information System (INIS)

    Beyer, H.K.; Oppel, G.; Bluemm, R.; Uhlenbrock, D.

    1988-01-01

    The article reports experience gained within three years with diagnostic NMR imaging of the lumbar spine. On the basis of results obtained by almost 500 examinations, an optimisation concept with regard to measuring sequences and orientation of sectional cuts is presented. Imaging of the spine in three planes, with sectional layer thickness between 3 and 5 mm, using a 1.5 Tesla system, seems to yield the diagnostic optimum, and in our opinion is superior over invasive myelography and CT scanning. A prospective study we made indicates a hit rate of 97.2%, and of 100% for evaluation of the results obtained with the 1.5 Tesla system together with an evaluation of the paraxial sections. The magnetic field intensity of 1.5 Tesla especially improves the quality of images of paraxial cuts as compared with the 0.5 Tesla field system, due to the better contrast-to-noise ratio, and thinner sections. (orig.) [de

  2. Methodology for quantitative evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.

    1981-01-01

    Of various approaches that might be taken to the diagnostic performance evaluation problem, Receiver Operating Characteristic (ROC) analysis holds great promise. Further development of the methodology for a unified, objective, and meaningful approach to evaluating the usefulness of medical imaging procedures is done by consideration of statistical significance testing, optimal sequencing of correlated studies, and analysis of observer performance

  3. Transient ischemic attack: diagnostic evaluation.

    Science.gov (United States)

    Messé, Steven R; Jauch, Edward C

    2008-08-01

    A transient ischemic attack portends significant risk of a stroke. Consequently, the diagnostic evaluation in the emergency department is focused on identifying high-risk causes so that preventive strategies can be implemented. The evaluation consists of a facilitated evaluation of the patient's metabolic, cardiac, and neurovascular systems. At a minimum, the following tests are recommended: fingerstick glucose level, electrolyte levels, CBC count, urinalysis, and coagulation studies; noncontrast computed tomography (CT) of the head; electrocardiography; and continuous telemetry monitoring. Vascular imaging studies, such as carotid ultrasonography, CT angiography, or magnetic resonance angiography, should be performed on an urgent basis and prioritized according to the patient's risk stratification for disease. Consideration should be given for echocardiography if no large vessel abnormality is identified.

  4. Evaluation of Diagnostic Tests Using Information Theory for Multi-Class Diagnostic Problems and its Application for the Detection of Occlusal Caries Lesions

    Directory of Open Access Journals (Sweden)

    Umut Arslan

    2014-09-01

    Full Text Available Background: Several methods are available to evaluate the performance of the tests when the purpose of the diagnostic test is to discriminate between two possible disease states. However multi-class diagnostic problems frequently appear in many areas of medical science. Hence, there is a need for methods which will enable us to characterize the accuracy of diagnostic tests when there are more than two possible disease states. Aims: To show that two information theory measures, information content (IC and proportional reduction in diagnostic uncertainty (PRDU, can be used for the evaluation of the performance of diagnostic tests for multi-class diagnostic problems that may appear in different areas of medical science. Study Design: Diagnostic accuracy study. Methods: Sixty freshly extracted permanent human molar and premolar teeth suspected to have occlusal caries lesions were selected for the study and were assessed by two experienced examiners. Each examiner performed two evaluations. Histological examination was used as the gold standard. The scores of the histological examination were defined as sound (n=11, enamel caries (n=22 and dentin caries (n=27. Diagnostic performance of i visual inspection, ii radiography, iii laser fluorescence (LF and iv micro-computed tomography (M-CT caries detection methods was evaluated by calculating IC and PRDU. Results: Micro-computed tomography examination was the best method among the diagnostic techniques for the diagnosis of occlusal caries in terms of both IC and PRDU. M-CT examination supplied the maximum diagnostic information about the diagnosis of occlusal caries in the first (IC: 1.056; p<0.05, (PRDU: 70.5% and second evaluation (IC: 1.105; p<0.05, (PRDU: 73.8% for the first examiner. M-CT examination was the best method among the diagnostic techniques for the second examiner in both the first (IC:1.105; p<0.05, (PRDU:73.8% and second evaluation (IC:1.061; p<0.05, (PRDU:70.8%. IC and PRDU were

  5. Does normalisation improve the diagnostic performance of apparent diffusion coefficient values for prostate cancer assessment? A blinded independent-observer evaluation

    International Nuclear Information System (INIS)

    Rosenkrantz, A.B.; Khalef, V.; Xu, W.; Babb, J.S.; Taneja, S.S.; Doshi, A.M.

    2015-01-01

    Aim: To evaluate the performance of normalised apparent diffusion coefficient (ADC) values for prostate cancer assessment when performed by independent observers blinded to histopathology findings. Materials and methods: Fifty-eight patients undergoing 3 T phased-array coil magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI; maximal b-value 1000 s/mm 2 ) before prostatectomy were included. Two radiologists independently evaluated the images, unaware of the histopathology findings. Regions of interest (ROIs) were drawn within areas showing visually low ADC within the peripheral zone (PZ) and transition zone (TZ) bilaterally. ROIs were also placed within regions in both lobes not suspicious for tumour, allowing computation of normalised ADC (nADC) ratios between suspicious and non-suspicious regions. The diagnostic performance of ADC and nADC were compared. Results: For PZ tumour detection, ADC achieved significantly higher area under the receiver operating characteristic curve (AUC; p=0.026) and specificity (p=0.021) than nADC for reader 1, and significantly higher AUC (p=0.025) than nADC for reader 2. For TZ tumour detection, nADC achieved significantly higher specificity (p=0.003) and accuracy (p=0.004) than ADC for reader 2. For PZ Gleason score >3+3 tumour detection, ADC achieved significantly higher AUC (p=0.003) and specificity (p=0.005) than nADC for reader 1, and significantly higher AUC (p=0.023) than nADC for reader 2. For TZ Gleason score >3+3 tumour detection, ADC achieved significantly higher specificity (p=0.019) than nADC for reader 1. Conclusion: In contrast to prior studies performing unblinded evaluations, ADC was observed to outperform nADC overall for two independent observers blinded to the histopathology findings. Therefore, although strategies to improve the utility of ADC measurements in prostate cancer assessment merit continued investigation, caution is warranted when applying normalisation to improve diagnostic

  6. Evaluation of laboratory diagnostic methods for cryptosporidiosis ...

    African Journals Online (AJOL)

    The conventional method of modified Ziehl-Neelsen (MZN) is very laborious, and stool ... Objective: This research was set to evaluate the diagnostic efficacy of ... 93.1% (MZN to ELISA) with ELISA techniques showing the highest sensitivity at ...

  7. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  8. Clinical diagnostic evaluation for scaphoid fractures: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Mallee, Wouter H.; Henny, Erik P.; van Dijk, C. Niek; Kamminga, Sjoerd P.; van Enst, Wynanda A.; Kloen, Peter

    2014-01-01

    To provide an overview of available clinical evaluation tests for scaphoid fractures and to compare their diagnostic accuracies. PWe performed a systematic review of all studies assessing diagnostic characteristics of clinical evaluation in scaphoid fractures by searching MEDLINE, EMBASE, Cochrane,

  9. Improving diagnostic accuracy using agent-based distributed data mining system.

    Science.gov (United States)

    Sridhar, S

    2013-09-01

    The use of data mining techniques to improve the diagnostic system accuracy is investigated in this paper. The data mining algorithms aim to discover patterns and extract useful knowledge from facts recorded in databases. Generally, the expert systems are constructed for automating diagnostic procedures. The learning component uses the data mining algorithms to extract the expert system rules from the database automatically. Learning algorithms can assist the clinicians in extracting knowledge automatically. As the number and variety of data sources is dramatically increasing, another way to acquire knowledge from databases is to apply various data mining algorithms that extract knowledge from data. As data sets are inherently distributed, the distributed system uses agents to transport the trained classifiers and uses meta learning to combine the knowledge. Commonsense reasoning is also used in association with distributed data mining to obtain better results. Combining human expert knowledge and data mining knowledge improves the performance of the diagnostic system. This work suggests a framework of combining the human knowledge and knowledge gained by better data mining algorithms on a renal and gallstone data set.

  10. Methodology for evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.E.

    1992-01-01

    Effort in this project during the past year has focused on the development, refinement, and distribution of computer software that will allow current Receiver Operating Characteristic (ROC) methodology to be used conveniently and reliably by investigators in a variety of evaluation tasks in diagnostic medicine; and on the development of new ROC methodology that will broaden the spectrum of evaluation tasks and/or experimental settings to which the fundamental approach can be applied. Progress has been limited by the amount of financial support made available to the project

  11. Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan

    International Nuclear Information System (INIS)

    Hyun, In Young; Lee, Dong Soo; Lee, Kyung Han; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kim, Kwang Myung; Choi, Hwang; Choi, Yong

    1995-01-01

    We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 children(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100% specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57% in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In duretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in loplsty, 6 extrarenal pelvis, and 3 immature kidneys of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 etrarenal pevis, 1 immature kidney of neonate , and 2 severe renal dysfunction, 1 vesicoureteral, reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvo-calyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of, neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  12. Stratified computed tomography findings improve diagnostic accuracy for appendicitis

    Science.gov (United States)

    Park, Geon; Lee, Sang Chul; Choi, Byung-Jo; Kim, Say-June

    2014-01-01

    AIM: To improve the diagnostic accuracy in patients with symptoms and signs of appendicitis, but without confirmative computed tomography (CT) findings. METHODS: We retrospectively reviewed the database of 224 patients who had been operated on for the suspicion of appendicitis, but whose CT findings were negative or equivocal for appendicitis. The patient population was divided into two groups: a pathologically proven appendicitis group (n = 177) and a non-appendicitis group (n = 47). The CT images of these patients were re-evaluated according to the characteristic CT features as described in the literature. The re-evaluations and baseline characteristics of the two groups were compared. RESULTS: The two groups showed significant differences with respect to appendiceal diameter, and the presence of periappendiceal fat stranding and intraluminal air in the appendix. A larger proportion of patients in the appendicitis group showed distended appendices larger than 6.0 mm (66.3% vs 37.0%; P appendicitis group. Furthermore, the presence of two or more of these factors increased the odds ratio to 6.8 times higher than baseline (95%CI: 3.013-15.454; P appendicitis with equivocal CT findings. PMID:25320531

  13. Learning from diagnostic errors: A good way to improve education in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Antonio, E-mail: antopin1968@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Acampora, Ciro, E-mail: itrasente@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Pinto, Fabio, E-mail: fpinto1966@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Kourdioukova, Elena, E-mail: Elena.Kourdioukova@UGent.be [Department of Radiology, Ghent University Hospital (UZG), MR/-1K12, De Pintelaan 185, B-9000 Ghent (Belgium); Romano, Luigia, E-mail: luigia.romano@fastwebnet.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Verstraete, Koenraad, E-mail: Koenraad.Verstraete@UGent.be [Department of Radiology, Ghent University Hospital (UZG), MR/-1K12, De Pintelaan 185, B-9000 Ghent (Belgium)

    2011-06-15

    Purpose: To evaluate the causes and the main categories of diagnostic errors in radiology as a method for improving education in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for original research publications discussing errors in diagnosis with specific reference to radiology. The search strategy employed different combinations of the following terms: (1) diagnostic radiology, (2) radiological error and (3) medical negligence. This review was limited to human studies and to English-language literature. Two authors reviewed all the titles and subsequently the abstracts of 491 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 75 selected articles was reviewed. Results: Several studies show that the etiology of radiological error is multi-factorial. The main category of claims against radiologists includes the misdiagnoses. Radiologic 'misses' typically are one of two types: either missed fractures or missed diagnosis of cancer. The most commonly missed fractures include those in the femur, the navicular bone, and the cervical spine. The second type of 'miss' is failure to diagnose cancer. Lack of appreciation of lung nodules on chest radiographs and breast lesions on mammograms are the predominant problems. Conclusion: Diagnostic errors should be considered not as signs of failure, but as learning opportunities.

  14. Learning from diagnostic errors: A good way to improve education in radiology

    International Nuclear Information System (INIS)

    Pinto, Antonio; Acampora, Ciro; Pinto, Fabio; Kourdioukova, Elena; Romano, Luigia; Verstraete, Koenraad

    2011-01-01

    Purpose: To evaluate the causes and the main categories of diagnostic errors in radiology as a method for improving education in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for original research publications discussing errors in diagnosis with specific reference to radiology. The search strategy employed different combinations of the following terms: (1) diagnostic radiology, (2) radiological error and (3) medical negligence. This review was limited to human studies and to English-language literature. Two authors reviewed all the titles and subsequently the abstracts of 491 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 75 selected articles was reviewed. Results: Several studies show that the etiology of radiological error is multi-factorial. The main category of claims against radiologists includes the misdiagnoses. Radiologic 'misses' typically are one of two types: either missed fractures or missed diagnosis of cancer. The most commonly missed fractures include those in the femur, the navicular bone, and the cervical spine. The second type of 'miss' is failure to diagnose cancer. Lack of appreciation of lung nodules on chest radiographs and breast lesions on mammograms are the predominant problems. Conclusion: Diagnostic errors should be considered not as signs of failure, but as learning opportunities.

  15. Inadequate Diagnostic Evaluation in Young Patients Registered with a Diagnosis of Dementia

    DEFF Research Database (Denmark)

    Salem, Lise Cronberg; Andersen, Birgitte Bo; Nielsen, T Rune

    2014-01-01

    BACKGROUND: Establishing a diagnosis of dementia in young patients may be complex and have significant implications for the patient. The aim of this study was to evaluate the quality of the diagnostic work-up in young patients diagnosed with dementia in the clinical routine. METHODS: Two hundred...... patients were randomly selected from 891 patients aged ≤65 years registered with a diagnosis of dementia for the first time in 2008 in Danish hospitals, and 159 medical records were available for review. Three raters evaluated their medical records for the completeness of the diagnostic work-up on which...... the diagnosis of dementia had been based, using evidence-based guidelines for the diagnostic evaluation of dementia as reference standards. RESULTS: According to the rater review, only 111 (70%) patients met the clinical criteria for dementia. An acceptable diagnostic work-up including all items of recommended...

  16. Statistical evaluation of diagnostic performance topics in ROC analysis

    CERN Document Server

    Zou, Kelly H; Bandos, Andriy I; Ohno-Machado, Lucila; Rockette, Howard E

    2016-01-01

    Statistical evaluation of diagnostic performance in general and Receiver Operating Characteristic (ROC) analysis in particular are important for assessing the performance of medical tests and statistical classifiers, as well as for evaluating predictive models or algorithms. This book presents innovative approaches in ROC analysis, which are relevant to a wide variety of applications, including medical imaging, cancer research, epidemiology, and bioinformatics. Statistical Evaluation of Diagnostic Performance: Topics in ROC Analysis covers areas including monotone-transformation techniques in parametric ROC analysis, ROC methods for combined and pooled biomarkers, Bayesian hierarchical transformation models, sequential designs and inferences in the ROC setting, predictive modeling, multireader ROC analysis, and free-response ROC (FROC) methodology. The book is suitable for graduate-level students and researchers in statistics, biostatistics, epidemiology, public health, biomedical engineering, radiology, medi...

  17. Climate Model Diagnostic and Evaluation: With a Focus on Satellite Observations

    Science.gov (United States)

    Waliser, Duane

    2011-01-01

    Each year, we host a summer school that brings together the next generation of climate scientists - about 30 graduate students and postdocs from around the world - to engage with premier climate scientists from the Jet Propulsion Laboratory and elsewhere. Our yearly summer school focuses on topics on the leading edge of climate science research. Our inaugural summer school, held in 2011, was on the topic of "Using Satellite Observations to Advance Climate Models," and enabled students to explore how satellite observations can be used to evaluate and improve climate models. Speakers included climate experts from both NASA and the National Oceanic and Atmospheric Administration (NOAA), who provided updates on climate model diagnostics and evaluation and remote sensing of the planet. Details of the next summer school will be posted here in due course.

  18. Evaluating the diagnostic device DETEC-PC for the thyroid uptakes

    International Nuclear Information System (INIS)

    Alonso Abad, Dolores; Arista Romeu, Eduardo; Alonso Abad, Ariel

    2008-01-01

    A study is presented for evaluating the diagnostic capacity of the DETEC-PC, detection measurement system for the Thyroid Uptakes. A clinical trial was designed for that effect and all the patients included were evaluated using the DETEC-PC and the well-known radioimmunoassay (RIA) standard diagnostic procedure known by acronym RIA. For the Thyroid Uptakes using the DETEC-PC patients received an oral administration of a solution of radioactive iodine. The radioactive substance is attracted chemically to the gland and ionising radiation detector captures their emissions. The iodine concentration in the Thyroid, as well as the variation of this concentration over time reflects the function of the gland. The RIA is based on the analysis of the values associated with the t3, t4 and tsh hormones, and when these three parameters are in a certain range the patients can be classified. The sample size was calculated in order to estimate the gross coincidence percent between both methods with a precision of 1 % at a confidence level of 95%. In total 110 patients were included in the trial. Mainly two types of statistical analysis were carried out, in the first analysis all the patients included in the study were considered whereas in the second analysis the patients with doubtful RIA results were not included. Ideally the performance of a diagnostic tool is evaluated through the estimation of its sensitivity and specificity. Nevertheless, in the present study the reference procedure (RIA) can not be considered a gold standard diagnostic device. In such a setting the international regulations advise to use measurements of agreement to evaluate the diagnostic capacity of the new method. In the present study we evaluated the level of diagnostic agreement between the DETEC-PC and the RIA using the Kappa statistics. Additionally, the confidence interval for the Kappa statistics and the corresponding significant test for the present of agreement were also computes. The obtained

  19. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    Science.gov (United States)

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  20. Undergoing Diagnostic Evaluation for Possible Cancer Affects the Health-Related Quality of Life in Patients Presenting with Non-Specific Symptoms

    DEFF Research Database (Denmark)

    Larsen, Ellen Frøsig Moseholm; Rydahl Hansen, Susan; Lindhardt, Bjarne Ørskov

    2016-01-01

    Aim Undergoing diagnostic evaluation for possible cancer can affect health-related quality of life (HRQoL). The aims of this study were to examine the HRQoL in patients undergoing a diagnostic evaluation for possible cancer due to non-specific symptoms and further to investigate the impact of socio...... diagnosis had the greatest effect on HRQoL around the time of diagnosis. Conclusions Patients with non-specific symptoms reported an affected HRQoL while undergoing a diagnostic evaluation for possible cancer. Morbidity, being unemployed and receiving a cancer diagnosis had the greatest effect on HRQo...... in the study; 680 (81%) also completed follow-up. Twenty-two percent of the patients received a cancer diagnosis at the end of follow-up. Patients presented initially with a high burden of symptoms, less role and emotional functioning and a lower global health/QoL. Most domains improved after diagnosis...

  1. Methodology for quantitative evaluation of diagnostic medical imaging

    International Nuclear Information System (INIS)

    Metz, C.

    1980-01-01

    This report deals with the evaluation of the performance of diagnostic medical imaging procedures using the Receiver Operating Characteristic or ROC analysis. The development of new tests for the statistical significance of apparent differences between ROC curves is discussed

  2. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    Science.gov (United States)

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  3. Prevalence of Autism Spectrum Disorder in Children Referred for Diagnostic Autism Evaluation.

    Science.gov (United States)

    Monteiro, Sonia A; Spinks-Franklin, Adiaha; Treadwell-Deering, Diane; Berry, Leandra; Sellers-Vinson, Sherry; Smith, Eboni; Proud, Monica; Voigt, Robert G

    2015-12-01

    Increased public awareness of autism spectrum disorders (ASD) and routine screening in primary care have contributed to increased requests for diagnostic ASD evaluations. However, given the scarcity of subspecialty autism diagnostic resources, overreferral of children suspected of having ASD may be contributing to long waiting lists at tertiary care autism centers and delaying diagnosis for those children who truly have ASD. To determine whether children are being excessively referred to ASD-specific diagnostic clinics, our objective was to determine the prevalence of true ASD diagnoses in children referred for diagnostic ASD evaluation. Charts of all patients referred to a regional autism center between April 2011 and August 2012 for suspicion of a possible ASD were retrospectively reviewed and demographic and clinical diagnoses abstracted. Only 214 of 348 patients evaluated (61%) received an ASD diagnosis. Thus, concerns about autism are not confirmed by an ASD diagnosis in a significant number of children. © The Author(s) 2015.

  4. Evaluation of the contribution of the importance of neuroimaging for the diagnostics of dementias - comparison to the psychological diagnostics

    International Nuclear Information System (INIS)

    Hentschel, F.; Kreis, M.; Damian, M.; Syren, M.; Krumm, B.

    2003-01-01

    Objective: While psychology is accepted as a necessary component of the dementia diagnostics, the extended clinical diagnostics with neuroimaging is differently estimated. The goal of the study is the quantification of the individual contribution of the two different methods. Methods: Of 100 patient the diagnosis of entrance, the neurological, the psychological, and the final clinical diagnosis were documented. For both imaging and psychology the sensitivity, specificity, and the positive predictive value were computed. The diagnostic of each method was determined from the change of the final in relation to the initial clinical diagnosis. The neuroradiological investigation took place with MRI, the psychological examination used both usual power and special speed tests. Results: The extended clinical diagnostics led for 26% of the patients to the change of the clinical diagnosis. Imaging and psychology supplied different own but supplementing contributions. In the case of annihilation imaging contributed with 73.3%, psychology with 54.1% to the diagnosis of a neurodegenerative dementia, whereas the contributions to the diagnosis of a vascular dementia were 83.3% and 70.8%, respectively. However psychology diagnosed and quantified the dementia. The contribution of neuroimaging consisted in the differential diagnosis of the dementias organic causes of symptomatic clementias and vascular encephalopathy without dementia but with consequences for a secondary prophylaxis were additional information also. Conclusion: Psychology improves the diagnostic accuracy of dementias. Neuroimaging improves the differential diagnosis of dementias and supplies additional clinically relevant findings. In the qualified diagnostics and differential diagnostics of the dementias both methods are indispensable. (orig.) [de

  5. Requirements for appropriate evaluation of diagnostic tests in suspected pulmonary embolism

    NARCIS (Netherlands)

    Sanson, B. J.; Meinders, A. J.; Kraaijenhagen, R. A.; van Beek, E. J.; Büller, H. R.

    1999-01-01

    In contrast to the development of new drugs, strict guidelines for the development of new diagnostic methods do not exist. A diagnostic test can be made available without proper evaluation of its clinical utility, which can lead to its premature introduction and inappropriate use. In this review

  6. An ARM data-oriented diagnostics package to evaluate the climate model simulation

    Science.gov (United States)

    Zhang, C.; Xie, S.

    2016-12-01

    A set of diagnostics that utilize long-term high frequency measurements from the DOE Atmospheric Radiation Measurement (ARM) program is developed for evaluating the regional simulation of clouds, radiation and precipitation in climate models. The diagnostics results are computed and visualized automatically in a python-based package that aims to serve as an easy entry point for evaluating climate simulations using the ARM data, as well as the CMIP5 multi-model simulations. Basic performance metrics are computed to measure the accuracy of mean state and variability of simulated regional climate. The evaluated physical quantities include vertical profiles of clouds, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, radiative fluxes, aerosol and cloud microphysical properties. Process-oriented diagnostics focusing on individual cloud and precipitation-related phenomena are developed for the evaluation and development of specific model physical parameterizations. Application of the ARM diagnostics package will be presented in the AGU session. This work is performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, IM release number is: LLNL-ABS-698645.

  7. Evaluation of written patient educational materials in the field of diagnostic imaging

    International Nuclear Information System (INIS)

    Ryhaenen, A.M.; Johansson, K.; Virtanen, H.; Salo, S.; Salanterae, S.; Leino-Kilpi, H.

    2009-01-01

    Aim: To evaluate the quality of written educational materials for diagnostic imaging (radiological and nuclear medicine) patients. Materials and methods: Written educational materials (n = 70) for diagnostic imaging patients were analysed. The materials were evaluated based on their external appearance (9 criteria), instructiveness (7), content (7), language and structure (8) and readability (1). Deductive content analysis was used. Quantified parts of the analyses were analysed by SAS for Windows. Dependence between criteria (32) was tested by Pearson correlation coefficients. Results: The external appearance fulfilled almost completely the criteria of good written education materials. The instructiveness was addressed clearly, except for the purpose of the material. The contents of materials dealt with bio-physiological, functional and cognitive dimensions of knowledge, while financial dimensions of knowledge were hardly dealt with at all. The language and the structure were reasonably good, but the language was partly in passive voice and the text contained strange words. Most of the education material was moderately easy to read. Conclusions: The results show that the quality of material was quite good in all dimensions. Only a small number of criteria were unsatisfactory. The results can be used to further improve written patient education materials and patient education in the imaging unit.

  8. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  9. Evaluation of tuberculosis diagnostics in children: 1. Proposed clinical case definitions for classification of intrathoracic tuberculosis disease. Consensus from an expert panel.

    Science.gov (United States)

    Graham, Stephen M; Ahmed, Tahmeed; Amanullah, Farhana; Browning, Renee; Cardenas, Vicky; Casenghi, Martina; Cuevas, Luis E; Gale, Marianne; Gie, Robert P; Grzemska, Malgosia; Handelsman, Ed; Hatherill, Mark; Hesseling, Anneke C; Jean-Philippe, Patrick; Kampmann, Beate; Kabra, Sushil Kumar; Lienhardt, Christian; Lighter-Fisher, Jennifer; Madhi, Shabir; Makhene, Mamodikoe; Marais, Ben J; McNeeley, David F; Menzies, Heather; Mitchell, Charles; Modi, Surbhi; Mofenson, Lynne; Musoke, Philippa; Nachman, Sharon; Powell, Clydette; Rigaud, Mona; Rouzier, Vanessa; Starke, Jeffrey R; Swaminathan, Soumya; Wingfield, Claire

    2012-05-15

    There is a critical need for improved diagnosis of tuberculosis in children, particularly in young children with intrathoracic disease as this represents the most common type of tuberculosis in children and the greatest diagnostic challenge. There is also a need for standardized clinical case definitions for the evaluation of diagnostics in prospective clinical research studies that include children in whom tuberculosis is suspected but not confirmed by culture of Mycobacterium tuberculosis. A panel representing a wide range of expertise and child tuberculosis research experience aimed to develop standardized clinical research case definitions for intrathoracic tuberculosis in children to enable harmonized evaluation of new tuberculosis diagnostic technologies in pediatric populations. Draft definitions and statements were proposed and circulated widely for feedback. An expert panel then considered each of the proposed definitions and statements relating to clinical definitions. Formal group consensus rules were established and consensus was reached for each statement. The definitions presented in this article are intended for use in clinical research to evaluate diagnostic assays and not for individual patient diagnosis or treatment decisions. A complementary article addresses methodological issues to consider for research of diagnostics in children with suspected tuberculosis.

  10. Evaluation of Tuberculosis Diagnostics in Children: 1. Proposed Clinical Case Definitions for Classification of Intrathoracic Tuberculosis Disease. Consensus From an Expert Panel

    Science.gov (United States)

    Graham, Stephen M.; Ahmed, Tahmeed; Amanullah, Farhana; Browning, Renee; Cardenas, Vicky; Casenghi, Martina; Cuevas, Luis E.; Gale, Marianne; Gie, Robert P.; Grzemska, Malgosia; Handelsman, Ed; Hatherill, Mark; Hesseling, Anneke C.; Jean-Philippe, Patrick; Kampmann, Beate; Kabra, Sushil Kumar; Lienhardt, Christian; Lighter-Fisher, Jennifer; Madhi, Shabir; Makhene, Mamodikoe; Marais, Ben J.; McNeeley, David F.; Menzies, Heather; Mitchell, Charles; Modi, Surbhi; Mofenson, Lynne; Musoke, Philippa; Nachman, Sharon; Powell, Clydette; Rigaud, Mona; Rouzier, Vanessa; Starke, Jeffrey R.; Swaminathan, Soumya; Wingfield, Claire

    2012-01-01

    There is a critical need for improved diagnosis of tuberculosis in children, particularly in young children with intrathoracic disease as this represents the most common type of tuberculosis in children and the greatest diagnostic challenge. There is also a need for standardized clinical case definitions for the evaluation of diagnostics in prospective clinical research studies that include children in whom tuberculosis is suspected but not confirmed by culture of Mycobacterium tuberculosis. A panel representing a wide range of expertise and child tuberculosis research experience aimed to develop standardized clinical research case definitions for intrathoracic tuberculosis in children to enable harmonized evaluation of new tuberculosis diagnostic technologies in pediatric populations. Draft definitions and statements were proposed and circulated widely for feedback. An expert panel then considered each of the proposed definitions and statements relating to clinical definitions. Formal group consensus rules were established and consensus was reached for each statement. The definitions presented in this article are intended for use in clinical research to evaluate diagnostic assays and not for individual patient diagnosis or treatment decisions. A complementary article addresses methodological issues to consider for research of diagnostics in children with suspected tuberculosis. PMID:22448023

  11. Clinical application and evaluation of the diagnostic significance of NMR-tomography

    International Nuclear Information System (INIS)

    Bielke, G.; Higer, P.

    1987-01-01

    Aim of the project was the clinical application and evaluation of the diagnostic significance of NMR-tomography. About 3 000 patients have been examined especially with diseases of the brain. In 75% of all cases pathological findings could be detected. A subgroup of these patients was used for comprehensive studies with regard to tissue characterization based on the calculation of relaxation time parameters. With methods of image processing and classification techniques we tried to get a clear correlation between combined NMR-parameters and human tissue types. The results show that this procedure is able to improve the detectibility and the association to finding groups and tumorgradings in certain cases. (orig./ECB) With 134 refs., 17 tabs., 86 figs [de

  12. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    Science.gov (United States)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  13. Advancing the research agenda for diagnostic error reduction.

    Science.gov (United States)

    Zwaan, Laura; Schiff, Gordon D; Singh, Hardeep

    2013-10-01

    Diagnostic errors remain an underemphasised and understudied area of patient safety research. We briefly summarise the methods that have been used to conduct research on epidemiology, contributing factors and interventions related to diagnostic error and outline directions for future research. Research methods that have studied epidemiology of diagnostic error provide some estimate on diagnostic error rates. However, there appears to be a large variability in the reported rates due to the heterogeneity of definitions and study methods used. Thus, future methods should focus on obtaining more precise estimates in different settings of care. This would lay the foundation for measuring error rates over time to evaluate improvements. Research methods have studied contributing factors for diagnostic error in both naturalistic and experimental settings. Both approaches have revealed important and complementary information. Newer conceptual models from outside healthcare are needed to advance the depth and rigour of analysis of systems and cognitive insights of causes of error. While the literature has suggested many potentially fruitful interventions for reducing diagnostic errors, most have not been systematically evaluated and/or widely implemented in practice. Research is needed to study promising intervention areas such as enhanced patient involvement in diagnosis, improving diagnosis through the use of electronic tools and identification and reduction of specific diagnostic process 'pitfalls' (eg, failure to conduct appropriate diagnostic evaluation of a breast lump after a 'normal' mammogram). The last decade of research on diagnostic error has made promising steps and laid a foundation for more rigorous methods to advance the field.

  14. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  15. Evaluating next-generation sequencing for direct clinical diagnostics in diarrhoeal disease

    DEFF Research Database (Denmark)

    Joensen, Katrine Grimstrup; Engsbro, A L Ø; Lukjancenko, Oksana

    2017-01-01

    The accurate microbiological diagnosis of diarrhoea involves numerous laboratory tests and, often, the pathogen is not identified in time to guide clinical management. With next-generation sequencing (NGS) becoming cheaper, it has huge potential in routine diagnostics. The aim of this study...... was to evaluate the potential of NGS-based diagnostics through direct sequencing of faecal samples. Fifty-eight clinical faecal samples were obtained from patients with diarrhoea as part of the routine diagnostics at Hvidovre University Hospital, Denmark. Ten samples from healthy individuals were also included...

  16. Diagnostic Accuracy of Coronary CT Angiography for the Evaluation of Bioresorbable Vascular Scaffolds

    DEFF Research Database (Denmark)

    Collet, Carlos; Chevalier, Bernard; Cequier, Angel

    2018-01-01

    : 44 to 90) and a specificity of 82% (95% CI: 75 to 87). The diagnostic accuracy of coronary CTA was similar to coronary angiography in its ability to identify patients with a significant lesion based on the IVUS criteria (p = 0.75). CONCLUSIONS: Coronary CTA has good diagnostic accuracy to detect in-scaffold...... luminal obstruction and to assess luminal dimensions after BVS implantation. Coronary angiography and coronary CTA yielded similar diagnostic accuracy to identify the presence and severity of obstructive disease. Coronary CTA might become the method of choice for the evaluation of patients treated......OBJECTIVES: To assess the diagnostic accuracy of coronary computed tomography angiography (CTA) for bioresorbable vascular scaffold (BVS) evaluation. BACKGROUND: Coronary CTA has emerged as a noninvasive method to evaluate patients with suspected or established coronary artery disease...

  17. Evaluation of PC-based diagnostic radiology workstations

    International Nuclear Information System (INIS)

    Pollack, T.; Brueggenwerth, G.; Kaulfuss, K.; Niederlag, W.

    2000-01-01

    Material and Methods: During February 1999 and September 1999 medical users at the hospital Dresden-Friedrichstadt Germany had tested 7 types of radiology diagnostic workstations. Two types of test methods were used: In test type 1 ergonomic and handling functions were evaluated impartial according to 78 selected user requirements. In test type 2 radiologists and radiographers (3+4) performed 23 work flow steps with a subjectively evaluation. Results: By using a progressive rating no product could fully meet the user requirements. As a result of the summary evaluation for test 1 and test 2 the following compliance rating was calculated for the different products: Rad Works (66%), Magic View (63%), ID-Report (58%), Impax 3000 (53%), Medical Workstation (52%), Pathspeed (46%) and Autorad (39%). (orig.) [de

  18. Improved timestep-size diagnostic edits for TRAC-P

    International Nuclear Information System (INIS)

    Giguere, P.T.

    1996-04-01

    Improvements have been made to the timestep-size selection logic diagnostic edits of the Transient Reactor Analysis Code (TRAC), specifically to the TRAC-P version. These include both a precise account of the reason for the selection for individual timesteps and thermal-hydraulic information on mesh cells that control the timestep size. The new edits can be specified by user input as a range of timestep numbers, problem time, or both. A description of the current timestep controls in effect in TRAC-P is also given

  19. Improved timestep-size diagnostic edits for TRAC-P

    Energy Technology Data Exchange (ETDEWEB)

    Giguere, P.T. [Los Alamos National Lab., NM (United States). Technology and Safety Assessment Div.

    1996-04-01

    Improvements have been made to the timestep-size selection logic diagnostic edits of the Transient Reactor Analysis Code (TRAC), specifically to the TRAC-P version. These include both a precise account of the reason for the selection for individual timesteps and thermal-hydraulic information on mesh cells that control the timestep size. The new edits can be specified by user input as a range of timestep numbers, problem time, or both. A description of the current timestep controls in effect in TRAC-P is also given.

  20. Evaluation and construction of diagnostic criteria for inclusion body myositis

    Science.gov (United States)

    Mammen, Andrew L.; Amato, Anthony A.; Weiss, Michael D.; Needham, Merrilee

    2014-01-01

    Objective: To use patient data to evaluate and construct diagnostic criteria for inclusion body myositis (IBM), a progressive disease of skeletal muscle. Methods: The literature was reviewed to identify all previously proposed IBM diagnostic criteria. These criteria were applied through medical records review to 200 patients diagnosed as having IBM and 171 patients diagnosed as having a muscle disease other than IBM by neuromuscular specialists at 2 institutions, and to a validating set of 66 additional patients with IBM from 2 other institutions. Machine learning techniques were used for unbiased construction of diagnostic criteria. Results: Twenty-four previously proposed IBM diagnostic categories were identified. Twelve categories all performed with high (≥97%) specificity but varied substantially in their sensitivities (11%–84%). The best performing category was European Neuromuscular Centre 2013 probable (sensitivity of 84%). Specialized pathologic features and newly introduced strength criteria (comparative knee extension/hip flexion strength) performed poorly. Unbiased data-directed analysis of 20 features in 371 patients resulted in construction of higher-performing data-derived diagnostic criteria (90% sensitivity and 96% specificity). Conclusions: Published expert consensus–derived IBM diagnostic categories have uniformly high specificity but wide-ranging sensitivities. High-performing IBM diagnostic category criteria can be developed directly from principled unbiased analysis of patient data. Classification of evidence: This study provides Class II evidence that published expert consensus–derived IBM diagnostic categories accurately distinguish IBM from other muscle disease with high specificity but wide-ranging sensitivities. PMID:24975859

  1. Identification and diagnostic evaluation of possible dementia in general practice. A prospective study

    DEFF Research Database (Denmark)

    Waldorff, Frans Boch; Rishøj, Susanne; Waldemar, Gunhild

    2005-01-01

    , and 4 (3%) were treated for depression or referred for another condition. A total of 6 patients were lost to follow-up. In the remaining 102 undiagnosed patients the main reasons for not performing a diagnostic evaluation of dementia were patient/relative hesitation (34%), the GP thought that it would......OBJECTIVE: To investigate the rate of diagnostic evaluation of dementia for patients in whom a suspicion of dementia was raised, and to investigate reasons why a diagnostic evaluation was not always being performed. DESIGN: A prospective study among elderly patients aged 65+, and a follow-up study...... of dementia, laboratory-screening tests prescribed by the GPs and referral status after 6 months, and follow-up questionnaire. RESULTS: Of 793 patients a total of 138 patients were identified with possible dementia. Among the identified patients 26 (20%) were referred for further evaluation within 6 months...

  2. Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pontone, Gianluca; Bertella, Erika; Baggiano, Andrea; Mushtaq, Saima; Loguercio, Monica; Segurini, Chiara; Conte, Edoardo; Beltrama, Virginia; Annoni, Andrea; Formenti, Alberto; Petulla, Maria; Trabattoni, Daniela; Pepi, Mauro [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Andreini, Daniele; Montorsi, Piero; Bartorelli, Antonio L. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); University of Milan, Department of Cardiovascular Sciences and Community Health, Milan (Italy); Guaricci, Andrea I. [University of Foggia, Department of Cardiology, Foggia (Italy)

    2016-01-15

    The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. (orig.)

  3. Crohn's Disease Evaluated with Magnetic Resonance Enteroclysis: Diagnostic Performance of Experienced and Inexperienced Readers before and after Training

    International Nuclear Information System (INIS)

    Negaard, A.; Mulahasanovic, A.; Reisaeter, L.A.; Aasekjaer, K.; Sandvik, L.; Klow, N.E.

    2008-01-01

    Background: Magnetic resonance enteroclysis (MRE) is suggested to become the preferred radiological method in small-bowel Crohn's disease (CD). However, the performance of inexperienced readers may influence the diagnostic value of the method and has not been previously investigated. Purpose: To compare readings of MRE in small-bowel CD performed by experienced and inexperienced readers before and after training.Material and Methods: One experienced radiologist (observer 1) and two trainees (observers 2 and 3) reviewed 60 MRE examinations. A second reading was performed after training. Bowel wall thickness (BWT), ulcers (BWU), stenosis (BWS), fistulas (FIS), and abscesses (ABS) were evaluated. A reference standard based on clinical records was established. Results: BWT in the terminal ileum was evaluated with high diagnostic performance (sensitivity: observer 1, 83%; observer 2, 72%; observer 3, 78%). Only BWU was diagnosed with a higher sensitivity by observer 1 (78% vs. 33% and 39%, respectively; P=0.02). False-positive findings for BWT in the jejunum (observer 2: 7; observer 3: 4) and fistulas and abscesses (observer 2: 11/5; observer 3: 5/4) were made by the trainees. Interobserver agreement in the jejunum was poor (observer 1/observer 2: κ=0.23; observer 1/observer 3: κ=-0.03) and in the ileum good (observer 1/observer 2: κ=0.78; observer 1/observer 3: κ=0.73). After training, evaluation of BWU (observer 2: 56%, P=0.22; observer 3: 44%, P=0.03), BWT (observer 2: 2; observer 3: 2), and interobserver agreement in the jejunum improved (observer 1/observer 2: κ=0.66; observer 1/observer 3: κ=0.66). However, the number of diagnosed fistulas and abscesses remained high. Conclusion: Before training, most findings of Crohn's disease in the terminal ileum were evaluated with high diagnostic performance by all readers. However, the inexperienced readers evaluated BWU with a low sensitivity and overestimated the number of FIS, number of ABS, and increased BWT in

  4. Cost-effectiveness of using a molecular diagnostic test to improve preoperative diagnosis of thyroid cancer.

    Science.gov (United States)

    Najafzadeh, Mehdi; Marra, Carlo A; Lynd, Larry D; Wiseman, Sam M

    2012-12-01

    Fine-needle aspiration biopsy (FNAB) is a safe and inexpensive diagnostic procedure for evaluating thyroid nodules.Up to 25% of the results from an FNAB, however, may not be diagnostic or may be indeterminate, leading to a subsequent diagnostic thyroid surgery. A new molecularly based diagnostic test could potentially reduce indeterminate cytological results and, with high accuracy, provide a definitive diagnosis for cancer in thyroid nodules. The aim of the study was to estimate the cost-effectiveness of utilizing a molecular diagnostic (DX) test as an adjunct to FNAB, compared with NoDX, to improve the preoperative diagnosis of thyroid nodules. We constructed a patient-level simulation model to estimate the clinical and economic outcomes of using a DX test compared with current practice (NoDX) for the diagnosis of thyroid nodules. By using a cost-effectiveness framework, we measured incremental clinical benefits in terms of quality-adjusted life-years and incremental costs over a 10-year time horizon. Assuming 95% sensitivity and specificity of the Dx test when used as an adjunct to FNAB, the utilization of the DX test resulted in a gain of 0.046 quality-adjusted life-years (95% confidence interval 0.019-0.078) and a saving of $1087 (95% confidence interval $691-$1533) in direct costs per patient. If the cost of the Dx test is less than $1087 per test, we expect to save quality-adjusted life-years and reduce costs when it is utilized. Sensitivity of the DX test, compared with specificity, had a larger influence on the overall outcomes. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  5. Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide

    Science.gov (United States)

    Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.

    2017-01-01

    Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…

  6. Physics measurements on WWER-440 diagnostic assemblies

    International Nuclear Information System (INIS)

    Dach, K.; Jirousek, V.; Kott, J.; Horak, J.; Teren, S.; Nemec, J.

    1980-01-01

    The aims of physics measurements using diagnostic assemblies are the development of neutron noise diagnostics methods, the improvement of knowledge of the physical properties of the WWER reactor cores, the testing of computer programs, and the specification of nuclear safety criteria and the obtaining of information allowing the optimum nuclear fuel economy. The instrumentation of diagnostic assemblies is briefly described, including miniature fission chambers, SPN detectors and calorimeters. The method of evaluating and experimental testing is shown. (M.S.)

  7. Soft x-ray power diagnostic improvements at the Omega Laser Facility

    International Nuclear Information System (INIS)

    Sorce, C.; Schein, J.; Weber, F.; Widmann, K.; Campbell, K.; Dewald, E.; Turner, R.; Landen, O.; Jacoby, K.; Torres, P.; Pellinen, D.

    2006-01-01

    Soft x-ray power diagnostics are essential for evaluating high temperature laser plasma experiments. The Dante soft x-ray spectrometer, a core diagnostic for radiation flux and temperature measurements of Hohlraums, installed on the Omega Laser Facility at the Laboratory for Laser Energetics has recently undergone a series of upgrades. Work performed at Brookhaven National Laboratory for the development of the National Ignition Facility (NIF) Dante spectrometer enables the Omega Dante to offer a total of 18 absolutely calibrated channels in the energy range from 50 eV to 20 keV. This feature provides Dante with the capability to measure higher, NIF relevant, radiation temperatures with increased accuracy including a differentiation of higher energy radiation such as the Au M and L bands. Diagnostic monitoring using experimental data from directly driven Au spherical shots is discussed

  8. A vibroacoustic diagnostic system as an element improving road transport safety.

    Science.gov (United States)

    Komorska, Iwona

    2013-01-01

    Mechanical defects of a vehicle driving system can be dangerous on the road. Diagnostic systems, which monitor operations of electric and electronic elements and devices of vehicles, are continuously developed and improved, while defects of mechanical systems are still not managed properly. This article proposes supplementing existing on-board diagnostics with a system of diagnosing selected defects to minimize their impact. It presents a method of diagnosing mechanical defects of the engine, gearbox and other elements of the driving system on the basis of a model of the vibration signal obtained adaptively. This method is suitable for engine valves, engine head gasket, main gearbox, joints, etc.

  9. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  10. Diagnostic evaluation of rare lesions of the arteria poplitea

    International Nuclear Information System (INIS)

    Schmitt, R.; Christopoulos, G.; Froehner, S.; Binder, F.; Schweiger, H.

    2001-01-01

    Clinical and radiological findings of six patients are discussed who, due to a specific pathology of the arteria poplitea, developed claudicatio primarily in the lower leg. Applying MS-CT and MRI, the following lesions of the arteria poplitea wer found: bilateral aneurysm verum (1 case), unilateral aneurysm spurium (1 case), the arteria magna syndrome (1 case), entrapment syndrome (2 cases), and cystic adventitia degeneration. The outstanding diagnostic value of MR angiography combined with MR imaging is explained. Good knowledge of the specific pathology of the arteria poplitea is pre-requisite of efficient diagnostic evaluation, and prevention of thromboembolic complications, or ineffective therapy. (orig./CB) [de

  11. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  12. Evaluating photographic scales of facial pores and diagnostic agreement of tests using latent class models.

    Science.gov (United States)

    Ning, Yao; Qing, Zeng; Qing, Wang; Li, Li

    2017-02-01

    Ordinal severity scales illustrated by photographs have been widely developed to help dermatologists in evaluating skin problems or improvements. Numerous scales have been published, and none of them were used for assessing facial pores. A five-point photographic scale of facial pores was formulated, and photographs of pores on nasal ala from 128 female volunteers were acquired. Five dermatologists with similar experiences rated the 128 photographs independently using the reference photographs. Latent Class Models (LCM) were used to analyze the data. Firstly, we hypothesized that the conditional probabilities of the five dermatologists were identical to build the first LCM and without the restriction to formulate the second LCM. Conditional probability and posterior probability were also calculated. The five-point scales were ambiguous as the raters actually had difficulties in distinguishing between some adjacent categories. Adjacent categories were pooled for reanalyzing, and the model fitted well. The newly developed photographic scale of Chinese facial pores should be redefined to improve their quality and reproducibility in future studies. Standardized scales for the measurement of aging and response to cosmetic therapy were essential for assessing diagnostic experiment. The LCM can effectively deal with diagnostic test of agreement and reproducibility.

  13. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    International Nuclear Information System (INIS)

    Stieger, Stefan; Praschinger, Andrea; Kletter, Kurt; Kainberger, Franz

    2011-01-01

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  14. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    Energy Technology Data Exchange (ETDEWEB)

    Stieger, Stefan, E-mail: stefan.stieger@univie.ac.at [Department of Basic Psychological Research, School of Psychology, University of Vienna, Liebiggasse 5, A-1010 Vienna (Austria); Praschinger, Andrea, E-mail: andrea.praschinger@meduniwien.ac.at [Core Unit for Medical Education (BEMAW), Medical University of Vienna, Spitalgasse 23, BT87, P.O. 10, A-1097 Vienna (Austria); Kletter, Kurt, E-mail: kurt.kletter@meduniwien.ac.at [Department of Nuclear Medicine, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz, E-mail: franz.kainberger@meduniwien.ac.at [Department of Radiology, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2011-06-15

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  15. Cognitive diagnostic assessment via Bayesian evaluation of informative diagnostic hypotheses.

    NARCIS (Netherlands)

    Hoijtink, Herbert; Béland, Sébastien; Vermeulen, Jorine A.

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  16. Cognitive Diagnostic Assessment via Bayesian Evaluation of Informative Diagnostic Hypotheses

    NARCIS (Netherlands)

    Hoitink, Herbert; Beland, Sebastien; Vermeulen, Jorine

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  17. Facial diplegia: etiology, clinical manifestations, and diagnostic evaluation

    Directory of Open Access Journals (Sweden)

    Sefer Varol

    2015-12-01

    Full Text Available ABSTRACT Objective Facial diplegia (FD is a rare neurological manifestation with diverse causes. This article aims to systematically evaluate the etiology, diagnostic evaluation and treatment of FD. Method The study was performed retrospectively and included 17 patients with a diagnosis of FD. Results Patients were diagnosed with Guillain-Barré syndrome (GBS (11, Bickerstaff’s brainstem encephalitis (1, neurosarcoidosis (1, non-Hodgkin’s Lymphoma (1, tuberculous meningitis (1 herpes simplex reactivation (1 and idiopathic (1. In addition, two patients had developed FD during pregnancy. Conclusion Facial diplegia is an ominous symptom with widely varying causes that requires careful investigation.

  18. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  19. Modeling companion diagnostics in economic evaluations of targeted oncology therapies: systematic review and methodological checklist.

    Science.gov (United States)

    Doble, Brett; Tan, Marcus; Harris, Anthony; Lorgelly, Paula

    2015-02-01

    The successful use of a targeted therapy is intrinsically linked to the ability of a companion diagnostic to correctly identify patients most likely to benefit from treatment. The aim of this study was to review the characteristics of companion diagnostics that are of importance for inclusion in an economic evaluation. Approaches for including these characteristics in model-based economic evaluations are compared with the intent to describe best practice methods. Five databases and government agency websites were searched to identify model-based economic evaluations comparing a companion diagnostic and subsequent treatment strategy to another alternative treatment strategy with model parameters for the sensitivity and specificity of the companion diagnostic (primary synthesis). Economic evaluations that limited model parameters for the companion diagnostic to only its cost were also identified (secondary synthesis). Quality was assessed using the Quality of Health Economic Studies instrument. 30 studies were included in the review (primary synthesis n = 12; secondary synthesis n = 18). Incremental cost-effectiveness ratios may be lower when the only parameter for the companion diagnostic included in a model is the cost of testing. Incorporating the test's accuracy in addition to its cost may be a more appropriate methodological approach. Altering the prevalence of the genetic biomarker, specific population tested, type of test, test accuracy and timing/sequence of multiple tests can all impact overall model results. The impact of altering a test's threshold for positivity is unknown as it was not addressed in any of the included studies. Additional quality criteria as outlined in our methodological checklist should be considered due to the shortcomings of standard quality assessment tools in differentiating studies that incorporate important test-related characteristics and those that do not. There is a need to refine methods for incorporating the characteristics

  20. Component-resolved diagnostics in vernal conjunctivitis.

    Science.gov (United States)

    Armentia, Alicia; Sanchís, Eugenia; Montero, Javier A

    2016-10-01

    Conventional diagnostic tests in allergy are insufficient to clarify the cause of vernal conjunctivitis. Component-resolved diagnostic (CRD) by microarray allergen assay may be useful in detecting allergens that might be involved in the inflammatory process. In a recent trial in patients suffered from eosinophilic esophagitis, after 2 years of the CRD-guided exclusion diet and specific immunotherapy, significant clinical improvement was observed, and 68% of patients were discharged (cure based on negative biopsy, no symptoms, and no medication intake). Our new objective was to evaluate IgE-mediated hypersensitivity by CRD in tears and serum from patients with vernal conjunctivitis and treat patients with identified triggering allergens by specific immunotherapy. Twenty-five patients with vernal conjunctivitis were evaluated. The identified triggering allergens were n Lol p 1 (11 cases), n Cyn d 1 (eight cases), group 4 and 6 grasses (six cases) and group 5 of grasses (five cases). Prick test and pollen IgE were positive in one case. Clinical improvement was observed in 13/25 vernal conjunctivitis patients after 1-year specific immunotherapy. CRD seems to be a more sensitive diagnostic tool compared with prick test and IgE detection. Specific CRD-led immunotherapy may achieve clinical improvements in vernal conjunctivitis patients.

  1. [Results from a general training hospital for the implementation of a diagnostic workup for pulmonary embolism according to the Dutch Institute for Health Care Improvement

    NARCIS (Netherlands)

    Kamphuisen, P.W.; Jacobs, E.M.G.; Mol, J.J.; Rijnders, A.J.; Ullmann, E.F.

    2002-01-01

    OBJECTIVE: To evaluate the active implementation of the Dutch Institute for Healthcare Improvement's guideline for the diagnostic work-up for pulmonary embolism in a general training hospital, and to analyse reasons for not following the guideline strategy. DESIGN: Partly retrospective and partly

  2. [Evaluation of quality of HIV diagnostic procedures in Poland].

    Science.gov (United States)

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  3. On improving of efficiency of plasma diagnostics with the help of computer

    International Nuclear Information System (INIS)

    Temko, S.W.; Temko, K.W.; Kuz'min, S.K.

    1994-01-01

    The cloud of weakly ionized plasma contaminated by impurities is considered. Impurities are the large-size particles, resulting under influence of adhesion and coagulation. Impurities cause decrease conduction and increase of radiation energy losses. To precipitate impurities one can use ultrasonic coagulation. However, under the acting ultrasonics the turbulence arises and instabilities, disturbing the plasma state, can develop. To stabilize plasma state and to deposit impurities on the walls of gas-discharge camera one needs both the data on diagnostics and the results of calculations as well as the system of situation adaptive controlling. The situations are time-dependent plasma states. The control system is formed from the distributed microprocessors network and from controlling computer. Microprocessors are installed on diagnostic installations, on energy sources and on ultrasonic signals supplies. To improve reliability and refusal-stability of the control system an apparatus, program and time excessivenesses are used. An effective methods of diagnostics can be SHF-methods and laser diagnostics. To find optical calculating data the authors apply statistical thermodynamics of spatial clusters, which was proposed by the authors earlier. Computer compares under the given program the diagnostic data with the results of calculations and produces control responses both on power sources and on generators of ultrasonic signals

  4. Computational evaluation of a pencil ionization chamber in a standard diagnostic radiology beam

    International Nuclear Information System (INIS)

    Mendonca, Dalila Souza Costa; Neves, Lucio Pereira; Perini, Ana Paula; Belinato, Walmir

    2016-01-01

    In this work a pencil ionization chamber was evaluated. This evaluation consisted in the determination of the influence of the ionization chamber components in its response. For this purpose, the Monte Carlo simulations and the spectrum of the standard diagnostic radiology beam (RQR5) were utilized. The results obtained, showed that the influence of the ionization chamber components presented no significant influence on the chamber response. Therefore, this ionization chamber is a good alternative for dosimetry in diagnostic radiology. (author)

  5. Improvements to a high-frequency fiber-optic system for plasma diagnostics

    International Nuclear Information System (INIS)

    Ogle, J.W.; Lyons, P.B.; Looney, L.; Hocker, L.; Nelson, M.A.; Zagarino, P.A.; Davies, T.J.; Simmons, R.D.; Selk, R.; Hopkins, B.

    1981-01-01

    A system for high-frequency recording of plasma diagnostics has previously been reported. Substantial improvements have been made in the system response, dynamic range, and calibration of the system. Plastic-clad silica fiber is used as a radiation-to-light converter using the Cerenkov process. A spectral equalizer device is used to compensate for the material dispersion in the fiber, increasing the frequency response (approx. = 1 GHz-km) and the dynamic range (a factor of > 20 over a FWHM 1 nm, 50% transmitting interference filter). The calibration system uses a pulsed injection laser diode (< 100 ps FWHM) injected into the fiber at the radiation end of the fiber and detected by a microchannel plate photomultiplier tube on the recording end. The injection laser diode is triggered by a synchronous trigger delay unit, which also triggers a sampling or real time scope after as much as 10 μs delay with < 50 ps jitter. The system improvements are described in detail and the utility of these components in other plasma diagnostic systems is discussed

  6. The evaluation of diagnostic medical exposures in the Czech Republic

    International Nuclear Information System (INIS)

    Petrova, K.; Klener, V.; Heribanova, A.; Husak, V.; Masopust, J.

    1998-01-01

    Surveys were performed in the Czech Republic to evaluate diagnostic medical exposures. The results are presented in 4 tables: (i) burden from the use of radiopharmaceuticals (examination, radiopharmaceutical, no. of procedures, average administered activity, conversion factor, collective effective dose); (ii) use of radiopharmaceuticals at nuclear medicine departments (type of examination, type of radiopharmaceutical, no. of departments, average administered activity); (iii) reference levels of administered activity specified for some diagnostic procedures for the adult patient (examination, radionuclide, chemical form, administered activity); and (iv) X-ray examinations (examination, annual no. of procedures, effective dose, age distribution, sex distribution). (P.A.)

  7. CT fluoroscopy-guided renal tumour cutting needle biopsy. Retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. (orig.)

  8. CT fluoroscopy-guided renal tumour cutting needle biopsy. Retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu [Okayama University Medical School, Department of Radiology, Okayama (Japan)

    2018-01-15

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. (orig.)

  9. Evaluation of a diagnostic flow chart applying medical thoracoscopy, adenosine deaminase and T-SPOT.TB in diagnosis of tuberculous pleural effusion.

    Science.gov (United States)

    He, Y; Zhang, W; Huang, T; Wang, X; Wang, M

    2015-10-01

    To evaluate a diagnostic flow chart applying medical thoracoscoy (MT), adenosine deaminase (ADA) and T-SPOT.TB in diagnosis of tuberculous pleural effusion (TPE) at a high TB burden country. 136 patients with pleural effusion (PE) were enrolled and divided into TPE and Non-TPE group. MT (histology), PE ADA and T-SPOT.TB were conducted on all patients. ROC analysis was performed for the best cut-off value of PE ADA in detection of TPE. The diagnostic flow chart applying MT, ADA and T-SPOT.TB was evaluated for improving the limitations of each diagnostic method. ROC analysis showed that the best cut-off value of PE ADA was 30U/L. The sensitivity and specificity of these tests were calculated respectively to be: 71.4% (58.5%-81.6%) and 100% (95.4-100.0%) for MT, 92.9% (83.0-97.2%) and 68.8% (57.9-77.9%) for T-SPOT.TB, and 80.0% (69.6-88.1%) and 92.9% (82.7-98.0%) for PE ADA. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value and negative predictive value of the diagnostic flow chart were 96.4% (87.9-99.0%), 96.3% (89.6-98.7%), 25.714, 0.037, 97.4 and 94.9, respectively. The diagnostic flow chart applying MT, ADA and T-SPOT.TB is an accurate and rapid diagnostic method in detection of TPE.

  10. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    International Nuclear Information System (INIS)

    Debono, Josephine C; Poulos, Ann E

    2015-01-01

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed tool applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice

  11. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  12. A Comprehensive Diagnostic Framework for Evaluating Business Intelligence and Analytics Effectiveness

    Directory of Open Access Journals (Sweden)

    Neil Foshay

    2015-09-01

    Full Text Available Business intelligence and analytics (BIA initiatives are costly, complex and experience high failure rates. Organizations require effective approaches to evaluate their BIA capabilities in order to develop strategies for their evolution. In this paper, we employ a design science paradigm to develop a comprehensive BIA effectiveness diagnostic (BIAED framework that can be easily operationalized. We propose that a useful BIAED framework must assess the correct factors, should be deployed in the proper process context and acquire the appropriate input from different constituencies within an organization. Drawing on the BIAED framework, we further develop an online diagnostic toolkit that includes a comprehensive survey instrument. We subsequently deploy the diagnostic mechanism within three large organizations in North America (involving over 1500 participants and use the results to inform BIA strategy formulation. Feedback from participating organizations indicates that BIA diagnostic toolkit provides insights that are essential inputs to strategy development. This work addresses a significant research gap in the area of BIA effectiveness assessment.

  13. [Situational diagnostic of an evaluation process of professional perfomance].

    Science.gov (United States)

    Gonçalves, Vera Lúcia Mira; Leite, Maria Madalena Januário

    2004-01-01

    The aim of this study was to realize a diagnostic situational about the evaluation process of the nursing team performance of USP Hospital. Based in two guiding questions, it was carried out 9 interviews with nurses of this hospital. These interviews were analyzed according Analyze of Contend. The most frequent themes were: The meaning of evaluation; the feelings; the difficulties and facilities concerning the instrument and the capacitacion. This experience brought about many feelings, as well as aspects that either favor or make the execution of the evaluation difficult, showing the principal points of vulnerability of the process and, therefore, deserving better attention and short-term intervention.

  14. CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.

  15. MRI-based diagnostic imaging of the intratemporal facial nerve

    International Nuclear Information System (INIS)

    Kress, B.; Baehren, W.

    2001-01-01

    Detailed imaging of the five sections of the full intratemporal course of the facial nerve can be achieved by MRI and using thin tomographic section techniques and surface coils. Contrast media are required for tomographic imaging of pathological processes. Established methods are available for diagnostic evaluation of cerebellopontine angle tumors and chronic Bell's palsy, as well as hemifacial spasms. A method still under discussion is MRI for diagnostic evaluation of Bell's palsy in the presence of fractures of the petrous bone, when blood volumes in the petrous bone make evaluation even more difficult. MRI-based diagnostic evaluation of the idiopatic facial paralysis currently is subject to change. Its usual application cannot be recommended for routine evaluation at present. However, a quantitative analysis of contrast medium uptake of the nerve may be an approach to improve the prognostic value of MRI in acute phases of Bell's palsy. (orig./CB) [de

  16. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    2017-04-01

    Full Text Available Abstract Background Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. Methods We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1 what evidence aside from test accuracy was searched for and synthesised, 2 which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3 how/whether threshold effects were explored, 4 how the potential dependency between multiple tests in a pathway was accounted for, and 5 for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. Results The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings

  17. Visual Aids Improve Diagnostic Inferences and Metacognitive Judgment Calibration

    Directory of Open Access Journals (Sweden)

    Rocio eGarcia-Retamero

    2015-07-01

    Full Text Available Visual aids can improve comprehension of risks associated with medical treatments, screenings, and lifestyles. Do visual aids also help decision makers accurately assess their risk comprehension? That is, do visual aids help them become well calibrated? To address these questions, we investigated the benefits of visual aids displaying numerical information and measured accuracy of self-assessment of diagnostic inferences (i.e., metacognitive judgment calibration controlling for individual differences in numeracy. Participants included 108 patients who made diagnostic inferences about three medical tests on the basis of information about the sensitivity and false-positive rate of the tests and disease prevalence. Half of the patients received the information in numbers without a visual aid, while the other half received numbers along with a grid representing the numerical information. In the numerical condition, many patients --especially those with low numeracy-- misinterpreted the predictive value of the tests and profoundly overestimated the accuracy of their inferences. Metacognitive judgment calibration mediated the relationship between numeracy and accuracy of diagnostic inferences. In contrast, in the visual aid condition, patients at all levels of numeracy showed high-levels of inferential accuracy and metacognitive judgment calibration. Results indicate that accurate metacognitive assessment may explain the beneficial effects of visual aids and numeracy --a result that accords with theory suggesting that metacognition is an essential part of risk literacy. We conclude that well-designed risk communications can inform patients about health-relevant numerical information while helping them assess the quality of their own risk comprehension.

  18. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    Science.gov (United States)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  19. Action Research to Improve the Learning Space for Diagnostic Techniques†

    OpenAIRE

    Ariel, Ellen; Owens, Leigh

    2015-01-01

    The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of “knowledge” and “understanding.” The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engag...

  20. Quantitative evaluation of visual detection performance in medicine: ROC analysis and determination of diagnostic benefit

    International Nuclear Information System (INIS)

    Metz, C.E.; Starr, S.J.; Lusted, L.B.

    1976-01-01

    An ROC curve provides an empirical description of the trade-offs which are possible among the various types of correct and incorrect decisions as the human decision-maker varies one or more confidence thresholds. Conventional ROC curves measured in simple decision-making situations can, in some cases, be used to predict human decision performance in more complex situations. By considering both the consequences of the various types of diagnostic decisions and the overhead cost of a diagnostic study, one can use the ROC curve to evaluate the diagnostic usefulness of a study in any particular clinical context. Since the ROC curve describes the possible relationships among the probabilities of the various types of correct and incorrect decisions, it plays a central role in optimizing diagnostic strategies using the general techniques of decision analysis. Applications in radiographic image evaluation are described

  1. Phenotype analysis of early risk factors from electronic medical records improves image-derived diagnostic classifiers for optic nerve pathology

    Science.gov (United States)

    Chaganti, Shikha; Nabar, Kunal P.; Nelson, Katrina M.; Mawn, Louise A.; Landman, Bennett A.

    2017-03-01

    We examine imaging and electronic medical records (EMR) of 588 subjects over five major disease groups that affect optic nerve function. An objective evaluation of the role of imaging and EMR data in diagnosis of these conditions would improve understanding of these diseases and help in early intervention. We developed an automated image processing pipeline that identifies the orbital structures within the human eyes from computed tomography (CT) scans, calculates structural size, and performs volume measurements. We customized the EMR-based phenome-wide association study (PheWAS) to derive diagnostic EMR phenotypes that occur at least two years prior to the onset of the conditions of interest from a separate cohort of 28,411 ophthalmology patients. We used random forest classifiers to evaluate the predictive power of image-derived markers, EMR phenotypes, and clinical visual assessments in identifying disease cohorts from a control group of 763 patients without optic nerve disease. Image-derived markers showed more predictive power than clinical visual assessments or EMR phenotypes. However, the addition of EMR phenotypes to the imaging markers improves the classification accuracy against controls: the AUC improved from 0.67 to 0.88 for glaucoma, 0.73 to 0.78 for intrinsic optic nerve disease, 0.72 to 0.76 for optic nerve edema, 0.72 to 0.77 for orbital inflammation, and 0.81 to 0.85 for thyroid eye disease. This study illustrates the importance of diagnostic context for interpretation of image-derived markers and the proposed PheWAS technique provides a flexible approach for learning salient features of patient history and incorporating these data into traditional machine learning analyses.

  2. Contactless Diagnostics of Turbine Blade Vibration and Damage

    International Nuclear Information System (INIS)

    Prochazka, Pavel; Vanek, Frantisek

    2011-01-01

    The study deals with the contactless diagnostic method used for the identification of steam turbine blade strain, vibration and damage. The tip-timing method based on the evaluation of time differences of blade passages in different rotor revolutions has been modified and improved to provide more precise and reliable results. A new approach to the analysis of the amplitude and time differences of impulse signals generated by a blade passage has been applied. Amplitudes and frequencies of vibrations and static position of blades ascertained by the diagnostic process are used to establish the state of blade damage. A contactless diagnostic system VDS-UT based on magneto-resistive sensors was developed in the Institute of Thermomechanics Academy of Sciences of the Czech Republic. The system provides on-line monitoring of vibration amplitudes and frequencies of all blades and notification of possible blade damage. Evaluation of the axial and circumferential components of the deflections by measuring the amplitude of blade impulse signals results in an overall improvement of the method. Using magneto-resistive sensors, blade elongation and untwisting can be determined as well.

  3. Anticipated identification costs: Improving assortment evaluation by diagnostic attributes

    NARCIS (Netherlands)

    Herpen, van E.; Pieters, F.G.M.

    2007-01-01

    Abstract Consumers often make quick assessments of product assortments, to determine if these are worthwhile for further investigation. They anticipate how difficult it will be to distinguish the various options in the assortment, which will influence their assortment evaluations. We reason that

  4. Alterations in thoracolumbosacral movement when pain causing lameness has been improved by diagnostic analgesia.

    Science.gov (United States)

    Greve, L; Dyson, S; Pfau, T

    2017-06-01

    Lameness, thoracolumbosacral pain and reduced range of motion (ROM) often coexist; better understanding of their relationship is needed. The objectives were to determine if thoracolumbosacral movement of horses changes when pain causing lameness is improved by diagnostic analgesia. We hypothesised that reduction of lameness will increase ROM of the thoracolumbosacral region. Thirteen horses with different types of hind limb lameness were trotted in straight lines and lunged on a 10m diameter circle on left and right reins before and after lameness was subjectively substantially improved by diagnostic analgesia. Inertial sensor data were collected from the withers, thirteenth (T13) and eighteenth thoracic (T18) vertebrae, third lumbar (L3) vertebra, tubera sacrale (TS), left and right tubera coxae. ROM of flexion-extension, axial rotation, lateral bending, dorsoventral, lateral-lateral motion and vertical movement symmetry were quantified at each thoracolumbar site. Hiphike difference (HHD), maximum difference (MaxDiff) and minimum difference (MinDiff) for the pelvic sensors were measured. Percentage changes for before and after diagnostic analgesia were calculated; mean±standard deviation (SD) or median [interquartile range] were determined. Associations between the change in pelvic versus thoracolumbar movement symmetry after each local analgesic technique were tested. After resolution of lameness, HHD decreased by 7% [68%] (P=0.006). The MinDiff decreased significantly by 33% [61%] (P=0.01), 45±13% (P=0.005) and 52±23% (P=0.04), for TS, L3 and T18, respectively. There was significantly increased ROM in flexion-extension at T13, in axial rotation at T13, T18, L3 and in lateral-lateral ROM at L3. Thoracolumbosacral asymmetry and reduced ROM associated with lameness were both altered immediately by improvement in lameness using diagnostic analgesia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Improving the safety of room air pneumoperitoneum for diagnostic laparoscopy.

    Science.gov (United States)

    Ikechebelu, J I; Okeke, C A F

    2008-06-01

    Laparoscopic examination is a useful investigation in the evaluation of infertile women. To perform this test, pneumoperitoneum is required to distend the abdomen, improve visibility and displace the intestines out of the pelvis. Several gases have been used to achieve this purpose including Nitrous Oxide (N2O), Carbondioxide (CO2), Helium, Xenon andAir. This was a prospective study in a private fertility centre in Nnewi, Nigeria aimed at reducing the morbidities inherent in the use Room Air pneumoperitoneum for diagnostic laparoscopy. This was sequel to an earlier study, which revealed that women who had Room Air pneumoperitoneum had a higher port wound infection rate, abdominal discomfort (feeling of retained gas in the abdomen) and shoulder pain with resultant delayed return to normal activity than women who had Co2 pneumoperitoneum. This study demonstrated that the use of soda lime to purify the Room Air and a low pressure suction pump to evacuate the air after the procedure significantly reduced the wound infection rate and virtually eliminated the abdominal discomfort and shoulder pain associated with Room Air pneumoperitoneum. This was followed by early return to normal activity. Therefore, use of Room Air for pneumoperitoneum is safe and affordable. It is recommended for low resource settings.

  6. Improving access to new diagnostics through harmonised regulation: priorities for action

    Directory of Open Access Journals (Sweden)

    Ruth McNerney

    2014-04-01

    Full Text Available A new generation of diagnostic tests is being developed for use at the point of care that could save lives and reduce the spread of infectious diseases through early detection and treatment. It is important that patients in developing countries have access to these products at affordable prices and without delay. Regulation of medical products is intended to ensure safety and quality whilst balancing the need for timely access to beneficial new products. Current regulatory oversight of diagnostic tests in developing countries is highly variable and weak regulation allows poor-quality tests to enter the market. However, inefficient orover zealous regulation results in unnecessary delays, increases costs and acts as a barrier to innovation and market entry. Setting international standards and streamlining the regulatory process could reduce these barriers. Four priority activities have been identified where convergence of standards and protocols or joint review of data would be advantageous: (1 adoption of a common registration file for pre-market approval; (2 convergence of quality standards for manufacturing site inspections; (3 use of common evaluation protocols, aswell as joint review of data, to reduce unnecessary duplication of lengthy and costly clinical performance studies; and (4 use of networks of laboratories for post-market surveillance in order to monitor ongoing quality of diagnostic devices. The adoption and implementation of such measures in developing countries could accelerate access to new diagnostic tests that are safe and affordable.

  7. Improving access to new diagnostics through harmonised regulation: priorities for action.

    Science.gov (United States)

    McNerney, Ruth; Sollis, Kimberly; Peeling, Rosanna W

    2014-01-01

    A new generation of diagnostic tests is being developed for use at the point of care that could save lives and reduce the spread of infectious diseases through early detection and treatment. It is important that patients in developing countries have access to these products at affordable prices and without delay. Regulation of medical products is intended to ensure safety and quality whilst balancing the need for timely access to beneficial new products. Current regulatory oversight of diagnostic tests in developing countries is highly variable and weak regulation allows poor-quality tests to enter the market. However, inefficient or overzealous regulation results in unnecessary delays, increases costs and acts as a barrier to innovation and market entry. Setting international standards and streamlining the regulatory process could reduce these barriers. Four priority activities have been identified where convergence of standards and protocols or joint review of data would be advantageous: (1) adoption of a common registration file for pre-market approval; (2) convergence of quality standards for manufacturing site inspections; (3) use of common evaluation protocols, as well as joint review of data, to reduce unnecessary duplication of lengthy and costly clinical performance studies; and (4) use of networks of laboratories for post-market surveillance in order to monitor ongoing quality of diagnostic devices. The adoption and implementation of such measures in developing countries could accelerate access to new diagnostic tests that are safe and affordable.

  8. Serumferritin - diagnostic relevance and clinical usefulness

    Energy Technology Data Exchange (ETDEWEB)

    Linkesch, W [Vienna Univ. (Austria). 2. Medizinische Klinik

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value one should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e.g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia.

  9. Serumferritin - diagnostic relevance and clinical usefulness

    International Nuclear Information System (INIS)

    Linkesch, W.

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value on should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e. g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia. (Author)

  10. Evaluations of gonad and fetal doses for diagnostic radiology.

    Science.gov (United States)

    Tung, C J; Tsai, H Y

    1999-07-01

    A national survey of patient doses for diagnostic radiology was planned in the Republic of China. We performed a pilot study for this survey to develop a protocol of the dose assessments. Entrance skin doses and organ (including ovary, testicle and uterus) doses were measured by thermoluminescent dosimeters and calculated by means of Monte Carlo simulations for several diagnostic procedures. We derived a formula and used the RadComp software for the computation of entrance skin doses. This formula involves several factors, such as kVp, mAs, the focus-to-skin-distance and aluminum filtration. RadComp software was applied to obtain free-air entrance exposures which were converted to entrance skin doses by considering the backscattering radiation from the body. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom for several diagnostic examinations. Genetically significant doses were calculated from ovary and testicle doses for the evaluation of hereditary effects. Embryo/fetal doses were determined from the uterine doses by considering the increase in uterus size with gestational age. We found that the patient doses studied in this work were all below the reference doses recommended by the National Radiological Protection Board of the U.K.

  11. Diagnostic tests and algorithms used in the investigation of haematuria: systematic reviews and economic evaluation.

    Science.gov (United States)

    Rodgers, M; Nixon, J; Hempel, S; Aho, T; Kelly, J; Neal, D; Duffy, S; Ritchie, G; Kleijnen, J; Westwood, M

    2006-06-01

    evaluated nuclear matrix protein 22 or bladder tumour antigen. The sensitivity and specificity ranges suggested that neither of these would be useful either for diagnosing bladder cancer or for ruling out patients for further investigation (cystoscopy). However, the evidence remains sparse and the diagnostic accuracy estimates varied widely between studies. Fifteen studies evaluating urine cytology as a test for urinary tract malignancies were heterogeneous and poorly reported. The calculated specificity values were generally high, suggesting some possible utility in confirming malignancy. However, the evidence suggests that urine cytology has no application in ruling out malignancy or excluding patients from further investigation. Fifteen studies evaluated imaging techniques [computed tomography (CT), intravenous urography (IVU) or ultrasound scanning (US)] to detect the underlying cause of haematuria. The target condition and the reference standard varied greatly between these studies. The diagnostic accuracy data for several individual studies appeared promising but meaningful comparison of the available imaging technologies was impossible. Eight studies met the inclusion criteria but addressed different parts of the diagnostic chain (e.g. screening programmes, laboratory investigations, full urological work-up). No single study addressed the complete diagnostic process. The review also highlighted a number of methodological limitations of these studies, including their lack of generalisability to the UK context. Separate decision analytic models were therefore developed to progress estimation of the optimal strategy for the diagnostic management of haematuria. The economic model for the detection of microhaematuria found that immediate microscopy following a positive dipstick test would improve diagnostic efficiency as it eliminates the high number of false positives produced by dipstick testing. Strategies that use routine microscopy may be associated with high numbers

  12. Climate Model Diagnostic Analyzer

    Science.gov (United States)

    Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei

    2015-01-01

    The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.

  13. Improving the Functional Diagnostic Process using Dynamic Master Logic Diagram (DMLD) Modeling Strategy

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2008-01-01

    In recent years, state based functional diagnostic systems have gained a growing attention among the model based diagnostic systems. They have been used to diagnose the new faults of the complex systems. On the other hand, a main point considered against it is its subjective, and the inability of reusing the knowledge gathered from one engineer by others. Different methods have been' suggested to solve these problems. In the same way, the suggested functional diagnostic system introduces the uses of Dynamic Master Logic Diagram (DMLD) modeling strategy for the functional diagnostic systems. DMLD has proven its power as a good modeling strategy. It can model the functions of the system's components in terms of a set of defined primitives for the domain of applications. However, the suggested system can use the DMLD technique to model the small functions of the system according to the defined primitives of its domain. So, the modeling process of the system is relatively invariant from one modeler to another. Also, the functions defined can be reused by other users in the domain for solving different problems. Besides, it can deal with the complex system in a flexible manner. Thus, the proposed system can improve the performance of the state based functional diagnostic systems. It can be applied for a wide area of the complex systems. It has been applied for a fluid system as a case of the real-time systems. The suggested system has proved its success as a powerful practical state based functional diagnostic system

  14. Evaluation of the Revised Algorithm of Autism Diagnostic Observation Schedule (ADOS) in the Diagnostic Investigation of High-Functioning Children and Adolescents with Autism Spectrum Disorders

    Science.gov (United States)

    Kamp-Becker, Inge; Ghahreman, Mardjan; Heinzel-Gutenbrunner, Monika; Peters, Mira; Remschmidt, Helmut; Becker, Katja

    2013-01-01

    The Autism Diagnostic Observation Schedule (ADOS) is a semi-structured, standardized assessment designed for use in diagnostic evaluation of individuals with suspected autism spectrum disorder (ASD). The ADOS has been effective in categorizing children who definitely have autism or not, but has lower specificity and sometimes sensitivity for…

  15. Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management

    Directory of Open Access Journals (Sweden)

    Emanuele Neri

    2010-12-01

    , improving overall diagnostic accuracy and potentially speeding up the clinical workflow of CTC image interpretation.Keywords: colonic polyps, colorectal cancer, colonoscopy, double contrast barium enema, computed tomography colonography

  16. Diagnostic reasoning strategies and diagnostic success.

    Science.gov (United States)

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  17. Secondary Signs May Improve the Diagnostic Accuracy of Equivocal Ultrasounds for Suspected Appendicitis in Children

    Science.gov (United States)

    Partain, Kristin N.; Patel, Adarsh; Travers, Curtis; McCracken, Courtney; Loewen, Jonathan; Braithwaite, Kiery; Heiss, Kurt F.; Raval, Mehul V.

    2016-01-01

    Introduction Ultrasound (US) is the preferred imaging modality for evaluating appendicitis. Our purpose was to determine if including secondary signs (SS) improves diagnostic accuracy in equivocal US studies. Methods Retrospective review identified 825 children presenting with concern for appendicitis and with a right lower quadrant (RLQ) US. Regression models identified which SS were associated with appendicitis. Test characteristics were demonstrated. Results 530 patients (64%) had equivocal US reports. Of 114 (22%) patients with equivocal US undergoing CT, those with SS were more likely to have appendicitis (48.6% vs 14.6%, pappendicitis (61.0% vs 33.6%, pappendicitis included fluid collection (adjusted odds ratio (OR) 13.3, 95% Confidence Interval (CI) 2.1–82.8), hyperemia (OR=2.0, 95%CI 1.5–95.5), free fluid (OR=9.8, 95%CI 3.8–25.4), and appendicolith (OR=7.9, 95%CI 1.7–37.2). Wall thickness, bowel peristalsis, and echogenic fat were not associated with appendicitis. Equivocal US that included hyperemia, a fluid collection, or an appendicolith had 96% specificity and 88% accuracy. Conclusion Use of SS in RLQ US assists in the diagnostic accuracy of appendicitis. SS may guide clinicians and reduce unnecessary CT and admissions. PMID:27039121

  18. Does PACS improve diagnostic accuracy in chest radiograph interpretations in clinical practice?

    International Nuclear Information System (INIS)

    Hurlen, Petter; Borthne, Arne; Dahl, Fredrik A.; Østbye, Truls; Gulbrandsen, Pål

    2012-01-01

    Objectives: To assess the impact of a Picture Archiving and Communication System (PACS) on the diagnostic accuracy of the interpretation of chest radiology examinations in a “real life” radiology setting. Materials and methods: During a period before PACS was introduced to radiologists, when images were still interpreted on film and reported on paper, images and reports were also digitally stored in an image database. The same database was used after the PACS introduction. This provided a unique opportunity to conduct a blinded retrospective study, comparing sensitivity (the main outcome parameter) in the pre and post-PACS periods. We selected 56 digitally stored chest radiograph examinations that were originally read and reported on film, and 66 examinations that were read and reported on screen 2 years after the PACS introduction. Each examination was assigned a random number, and both reports and images were scored independently for pathological findings. The blinded retrospective score for the original reports were then compared with the score for the images (the gold standard). Results: Sensitivity was improved after the PACS introduction. When both certain and uncertain findings were included, this improvement was statistically significant. There were no other statistically significant changes. Conclusion: The result is consistent with prospective studies concluding that diagnostic accuracy is at least not reduced after PACS introduction. The sensitivity may even be improved.

  19. Does sex influence the diagnostic evaluation of autism spectrum disorder in adults?

    Science.gov (United States)

    Wilson, C Ellie; Murphy, Clodagh M; McAlonan, Grainne; Robertson, Dene M; Spain, Debbie; Hayward, Hannah; Woodhouse, Emma; Deeley, P Quinton; Gillan, Nicola; Ohlsen, J Chris; Zinkstok, Janneke; Stoencheva, Vladimira; Faulkner, Jessica; Yildiran, Hatice; Bell, Vaughan; Hammond, Neil; Craig, Michael C; Murphy, Declan GM

    2016-01-01

    It is unknown whether sex influences the diagnostic evaluation of autism spectrum disorder, or whether male and female adults within the spectrum have different symptom profiles. This study reports sex differences in clinical outcomes for 1244 adults (935 males and 309 females) referred for autism spectrum disorder assessment. Significantly, more males (72%) than females (66%) were diagnosed with an autism spectrum disorder of any subtype (x2 = 4.09; p = 0.04). In high-functioning autism spectrum disorder adults (IQ > 70; N = 827), there were no significant sex differences in severity of socio-communicative domain symptoms. Males had significantly more repetitive behaviours/restricted interests than females (p = 0.001, d = 0.3). A multivariate analysis of variance indicated a significant interaction between autism spectrum disorder subtype (full-autism spectrum disorder/partial-autism spectrum disorder) and sex: in full-autism spectrum disorder, males had more severe socio-communicative symptoms than females; for partial-autism spectrum disorder, the reverse was true. There were no sex differences in prevalence of co-morbid psychopathologies. Sex influenced diagnostic evaluation in a clinical sample of adults with suspected autism spectrum disorder. The sexes may present with different manifestations of the autism spectrum disorder phenotype and differences vary by diagnostic subtype. Understanding and awareness of adult female repetitive behaviours/restricted interests warrant attention and sex-specific diagnostic assessment tools may need to be considered. PMID:26802113

  20. Evaluation of observed blast loading effects on NIF x-ray diagnostic collimators.

    Science.gov (United States)

    Masters, N D; Fisher, A; Kalantar, D; Prasad, R; Stölken, J S; Wlodarczyk, C

    2014-11-01

    We present the "debris wind" models used to estimate the impulsive load to which x-ray diagnostics and other structures are subject during National Ignition Facility experiments. These models are used as part of the engineering design process. Isotropic models, based on simulations or simplified "expanding shell" models, are augmented by debris wind multipliers to account for directional anisotropy. We present improvements to these multipliers based on measurements of the permanent deflections of diagnostic components: 4× for the polar direction and 2× within the equatorial plane-the latter relaxing the previous heuristic debris wind multiplier.

  1. Model-Independent Evaluation of Tumor Markers and a Logistic-Tree Approach to Diagnostic Decision Support

    Directory of Open Access Journals (Sweden)

    Weizeng Ni

    2014-01-01

    Full Text Available Sensitivity and specificity of using individual tumor markers hardly meet the clinical requirement. This challenge gave rise to many efforts, e.g., combing multiple tumor markers and employing machine learning algorithms. However, results from different studies are often inconsistent, which are partially attributed to the use of different evaluation criteria. Also, the wide use of model-dependent validation leads to high possibility of data overfitting when complex models are used for diagnosis. We propose two model-independent criteria, namely, area under the curve (AUC and Relief to evaluate the diagnostic values of individual and multiple tumor markers, respectively. For diagnostic decision support, we propose the use of logistic-tree which combines decision tree and logistic regression. Application on a colorectal cancer dataset shows that the proposed evaluation criteria produce results that are consistent with current knowledge. Furthermore, the simple and highly interpretable logistic-tree has diagnostic performance that is competitive with other complex models.

  2. Blood culture-negative endocarditis: Improving the diagnostic yield using new diagnostic tools.

    Science.gov (United States)

    Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier

    2017-11-01

    Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients.In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France.A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38.By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents

  3. Integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves diagnostic skills and visual-spatial ability

    Energy Technology Data Exchange (ETDEWEB)

    Rengier, Fabian, E-mail: fabian.rengier@web.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Häfner, Matthias F. [University Hospital Heidelberg, Department of Radiation Oncology, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Unterhinninghofen, Roland [Karlsruhe Institute of Technology (KIT), Institute for Anthropomatics, Department of Informatics, Adenauerring 2, 76131 Karlsruhe (Germany); Nawrotzki, Ralph; Kirsch, Joachim [University of Heidelberg, Institute of Anatomy and Cell Biology, Im Neuenheimer Feld 307, 69120 Heidelberg (Germany); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Giesel, Frederik L. [University of Heidelberg, Institute of Anatomy and Cell Biology, Im Neuenheimer Feld 307, 69120 Heidelberg (Germany); University Hospital Heidelberg, Department of Nuclear Medicine, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany)

    2013-08-15

    Purpose: Integrating interactive three-dimensional post-processing software into undergraduate radiology teaching might be a promising approach to synergistically improve both visual-spatial ability and radiological skills, thereby reducing students’ deficiencies in image interpretation. The purpose of this study was to test our hypothesis that a hands-on radiology course for medical students using interactive three-dimensional image post-processing software improves radiological knowledge, diagnostic skills and visual-spatial ability. Materials and methods: A hands-on radiology course was developed using interactive three-dimensional image post-processing software. The course consisted of seven seminars held on a weekly basis. The 25 participating fourth- and fifth-year medical students learnt to systematically analyse cross-sectional imaging data and correlated the two-dimensional images with three-dimensional reconstructions. They were instructed by experienced radiologists and collegiate tutors. The improvement in radiological knowledge, diagnostic skills and visual-spatial ability was assessed immediately before and after the course by multiple-choice tests comprising 64 questions each. Wilcoxon signed rank test for paired samples was applied. Results: The total number of correctly answered questions improved from 36.9 ± 4.8 to 49.5 ± 5.4 (p < 0.001) which corresponded to a mean improvement of 12.6 (95% confidence interval 9.9–15.3) or 19.8%. Radiological knowledge improved by 36.0% (p < 0.001), diagnostic skills for cross-sectional imaging by 38.7% (p < 0.001), diagnostic skills for other imaging modalities – which were not included in the course – by 14.0% (p = 0.001), and visual-spatial ability by 11.3% (p < 0.001). Conclusion: The integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves radiological reasoning, diagnostic skills and visual-spatial ability, and thereby

  4. Integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves diagnostic skills and visual-spatial ability

    International Nuclear Information System (INIS)

    Rengier, Fabian; Häfner, Matthias F.; Unterhinninghofen, Roland; Nawrotzki, Ralph; Kirsch, Joachim; Kauczor, Hans-Ulrich; Giesel, Frederik L.

    2013-01-01

    Purpose: Integrating interactive three-dimensional post-processing software into undergraduate radiology teaching might be a promising approach to synergistically improve both visual-spatial ability and radiological skills, thereby reducing students’ deficiencies in image interpretation. The purpose of this study was to test our hypothesis that a hands-on radiology course for medical students using interactive three-dimensional image post-processing software improves radiological knowledge, diagnostic skills and visual-spatial ability. Materials and methods: A hands-on radiology course was developed using interactive three-dimensional image post-processing software. The course consisted of seven seminars held on a weekly basis. The 25 participating fourth- and fifth-year medical students learnt to systematically analyse cross-sectional imaging data and correlated the two-dimensional images with three-dimensional reconstructions. They were instructed by experienced radiologists and collegiate tutors. The improvement in radiological knowledge, diagnostic skills and visual-spatial ability was assessed immediately before and after the course by multiple-choice tests comprising 64 questions each. Wilcoxon signed rank test for paired samples was applied. Results: The total number of correctly answered questions improved from 36.9 ± 4.8 to 49.5 ± 5.4 (p < 0.001) which corresponded to a mean improvement of 12.6 (95% confidence interval 9.9–15.3) or 19.8%. Radiological knowledge improved by 36.0% (p < 0.001), diagnostic skills for cross-sectional imaging by 38.7% (p < 0.001), diagnostic skills for other imaging modalities – which were not included in the course – by 14.0% (p = 0.001), and visual-spatial ability by 11.3% (p < 0.001). Conclusion: The integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves radiological reasoning, diagnostic skills and visual-spatial ability, and thereby

  5. Diagnostic Evaluation of Nontraumatic Chest Pain in Athletes.

    Science.gov (United States)

    Moran, Byron; Bryan, Sean; Farrar, Ted; Salud, Chris; Visser, Gary; Decuba, Raymond; Renelus, Deborah; Buckley, Tyler; Dressing, Michael; Peterkin, Nicholas; Coris, Eric

    This article is a clinically relevant review of the existing medical literature relating to the assessment and diagnostic evaluation for athletes complaining of nontraumatic chest pain. The literature was searched using the following databases for the years 1975 forward: Cochrane Database of Systematic Reviews; CINAHL; PubMed (MEDLINE); and SportDiscus. The general search used the keywords chest pain and athletes. The search was revised to include subject headings and subheadings, including chest pain and prevalence and athletes. Cross-referencing published articles from the databases searched discovered additional articles. No dissertations, theses, or meeting proceedings were reviewed. The authors discuss the scope of this complex problem and the diagnostic dilemma chest pain in athletes can provide. Next, the authors delve into the vast differential and attempt to simplify this process for the sports medicine physician by dividing potential etiologies into cardiac and noncardiac conditions. Life-threatening causes of chest pain in athletes may be cardiac or noncardiac in origin, which highlights the need for the sports medicine physician to consider pathology in multiple organ systems simultaneously. This article emphasizes the importance of ruling out immediately life threatening diagnoses, while acknowledging the most common causes of noncardiac chest pain in young athletes are benign. The authors propose a practical algorithm the sports medicine physician can use as a guide for the assessment and diagnostic work-up of the athlete with chest pain designed to help the physician arrive at the correct diagnosis in a clinically efficient and cost-effective manner.

  6. Resilient actions in the diagnostic process and system performance.

    Science.gov (United States)

    Smith, Michael W; Davis Giardina, Traber; Murphy, Daniel R; Laxmisan, Archana; Singh, Hardeep

    2013-12-01

    Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by 'resilient' actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analysed to identify barriers for rapid diagnostic evaluation, and PCPs' actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs' actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of 'downstream' measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety.

  7. Diagnostic evaluation of dementia in general practice in Denmark. A national survey

    DEFF Research Database (Denmark)

    Waldorff, Frans Boch; Møller, S

    2001-01-01

    OBJECTIVE: To examine GPs' self-reported basic diagnostic evaluation of dementia according to the recommendations in multidisciplinary consensus guidelines and to analyse explanatory factors for GP performance. DESIGN: Postal questionnaire study, spring 1998. SETTING: General practice in Denmark...

  8. Diagnostic performance of magnetic resonance imaging and pre-surgical evaluation in the assessment of traumatic intra-articular knee disorders in children and adolescents: what conditions still pose diagnostic challenges?

    Energy Technology Data Exchange (ETDEWEB)

    Gans, Itai; Ganley, Theodore J. [The Children' s Hospital of Philadelphia, Division of Orthopaedics, 34th and Civic Center Boulevard, Philadelphia, PA (United States); Bedoya, Maria A.; Ho-Fung, Victor [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2014-08-31

    Diagnosis of intra-articular lesions in children based on clinical examination and MRI is particularly challenging. To evaluate the diagnostic performance of MRI and pre-surgical evaluation of the knee in pediatric patients relative to arthroscopic evaluation as the gold standard. We report diagnoses frequently missed or inaccurately diagnosed pre-operatively. We conducted a retrospective review of MRI and pre-surgical evaluation in children and adolescents ages 1-17 years who were treated by knee arthroscopy during a 21/2-year period. All MRIs were reviewed by a pediatric radiologist blinded to clinical findings. Pediatric orthopedic clinic notes were reviewed for pre-surgical evaluation (based on physical exam, radiograph, MR images and radiologist's MRI report). Arthroscopic findings were used as the gold standard. We calculated the percentages of diagnoses at arthroscopy missed on both MRI and pre-surgical evaluation. Diagnostic accuracy between children and adolescents and in patients with one pathological lesion vs. those with >1 lesion was analyzed. We performed a second review of MR images of the missed or over-called MRI diagnoses with knowledge of arthroscopic findings. We included 178 children and adolescents. The most common diagnoses missed on MRI or pre-surgical evaluation but found at arthroscopy were: discoid meniscus (8/30, or 26.7% of cases); lateral meniscal tears (15/80, or 18.8% of cases); intra-articular loose bodies (5/36, or 13.9% of cases), and osteochondral injuries (9/73, or 12.3% of cases). Overall diagnostic accuracy of MRI and pre-surgical evaluation was 92.7% and 95.3%, respectively. No significant difference in diagnostic accuracy between children and adolescents was observed. When multiple intra-articular lesions were present, lateral meniscal tears were more likely to be inaccurately diagnosed (missed or over-called) on both MRI (P = 0.009) and pre-surgical evaluation (P < 0.001). Overall diagnostic accuracy of MRI and pre

  9. Diagnostic performance of magnetic resonance imaging and pre-surgical evaluation in the assessment of traumatic intra-articular knee disorders in children and adolescents: what conditions still pose diagnostic challenges?

    International Nuclear Information System (INIS)

    Gans, Itai; Ganley, Theodore J.; Bedoya, Maria A.; Ho-Fung, Victor

    2015-01-01

    Diagnosis of intra-articular lesions in children based on clinical examination and MRI is particularly challenging. To evaluate the diagnostic performance of MRI and pre-surgical evaluation of the knee in pediatric patients relative to arthroscopic evaluation as the gold standard. We report diagnoses frequently missed or inaccurately diagnosed pre-operatively. We conducted a retrospective review of MRI and pre-surgical evaluation in children and adolescents ages 1-17 years who were treated by knee arthroscopy during a 21/2-year period. All MRIs were reviewed by a pediatric radiologist blinded to clinical findings. Pediatric orthopedic clinic notes were reviewed for pre-surgical evaluation (based on physical exam, radiograph, MR images and radiologist's MRI report). Arthroscopic findings were used as the gold standard. We calculated the percentages of diagnoses at arthroscopy missed on both MRI and pre-surgical evaluation. Diagnostic accuracy between children and adolescents and in patients with one pathological lesion vs. those with >1 lesion was analyzed. We performed a second review of MR images of the missed or over-called MRI diagnoses with knowledge of arthroscopic findings. We included 178 children and adolescents. The most common diagnoses missed on MRI or pre-surgical evaluation but found at arthroscopy were: discoid meniscus (8/30, or 26.7% of cases); lateral meniscal tears (15/80, or 18.8% of cases); intra-articular loose bodies (5/36, or 13.9% of cases), and osteochondral injuries (9/73, or 12.3% of cases). Overall diagnostic accuracy of MRI and pre-surgical evaluation was 92.7% and 95.3%, respectively. No significant difference in diagnostic accuracy between children and adolescents was observed. When multiple intra-articular lesions were present, lateral meniscal tears were more likely to be inaccurately diagnosed (missed or over-called) on both MRI (P = 0.009) and pre-surgical evaluation (P < 0.001). Overall diagnostic accuracy of MRI and pre

  10. Echocardiographic evaluation of pre-diagnostic development in young relatives genetically predisposed to hypertrophic cardiomyopathy

    DEFF Research Database (Denmark)

    Jensen, Morten K; Havndrup, Ole; Christiansen, Michael

    2015-01-01

    Identification of the first echocardiographic manifestations of hypertrophic cardiomyopathy may be important for clinical management and our understanding of the pathogenesis. We studied the development of pre-diagnostic echocardiographic changes in young relatives to HCM patients during long...... of relatives with unknown genetic status. Children carrying pathogenic sarcomere gene mutations develop reduced LVEDd and increased E/e' as first pre-diagnostic echocardiographic manifestations during follow-up into adulthood.......-term years follow-up. HCM-relatives not fulfilling the diagnostic criteria for HCM and age of family screening of 11 sarcomere genes, CRYAB, α-GAL, and titin, we evaluated...

  11. Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative

    International Nuclear Information System (INIS)

    Bossuyt, P.M.; Reitsma, J.B.; Bruns, D.E.; Gatsonis, C.A.; Glasziou, P.P.; Irwig, L.M.; Lijmer, J.G.; Moher, D.; Rennie, D.; Vet, H.C.W. de

    2003-01-01

    AIM: To improve the accuracy and completeness of reporting of studies of diagnostic accuracy in order to allow readers to assess the potential for bias in a study and to evaluate the general isability of its results. METHODS: The standards for reporting of diagnostic accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a 2 day consensus meeting with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. RESULTS: The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25-item checklist, by using evidence whenever available. A prototype of a flow diagram provides information about the method of recruitment of patients, the order of test execution and the numbers of patients undergoing the test under evaluation, the reference standard, or both. CONCLUSIONS: Evaluation of research depends on complete and accurate reporting. If medical journals adopt the checklist and the flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public

  12. ARM Data-Oriented Metrics and Diagnostics Package for Climate Model Evaluation Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chengzhu [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Xie, Shaocheng [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-15

    A Python-based metrics and diagnostics package is currently being developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Infrastructure Team at Lawrence Livermore National Laboratory (LLNL) to facilitate the use of long-term, high-frequency measurements from the ARM Facility in evaluating the regional climate simulation of clouds, radiation, and precipitation. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The Coupled Model Intercomparison Project (CMIP) model data sets are also included in the package to enable model intercomparison as demonstrated in Zhang et al. (2017). The mean of the CMIP model can serve as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, and radiative fluxes, with plan to extend to more fields, such as aerosol and microphysics properties. Process-oriented diagnostics focusing on individual cloud- and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. The version 1.0 package is designed based on data collected at ARM’s Southern Great Plains (SGP) Research Facility, with the plan to extend to other ARM sites. The metrics and diagnostics package is currently built upon standard Python libraries and additional Python packages developed by DOE (such as CDMS and CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first present the input data, which

  13. Improving the Accessibility and Efficiency of Point-of-Care Diagnostics Services in Low- and Middle-Income Countries: Lean and Agile Supply Chain Management.

    Science.gov (United States)

    Kuupiel, Desmond; Bawontuo, Vitalis; Mashamba-Thompson, Tivani P

    2017-11-29

    Access to point-of-care (POC) diagnostics services is essential for ensuring rapid disease diagnosis, management, control, and surveillance. POC testing services can improve access to healthcare especially where healthcare infrastructure is weak and access to quality and timely medical care is a challenge. Improving the accessibility and efficiency of POC diagnostics services, particularly in resource-limited settings, may be a promising route to improving healthcare outcomes. In this review, the accessibility of POC testing is defined as the distance/proximity to the nearest healthcare facility for POC diagnostics service. This review provides an overview of the impact of POC diagnostics on healthcare outcomes in low- and middle-income countries (LMICs) and factors contributing to the accessibility of POC testing services in LMICs, focusing on characteristics of the supply chain management and quality systems management, characteristics of the geographical location, health infrastructure, and an enabling policy framework for POC diagnostics services. Barriers and challenges related to the accessibility of POC diagnostics in LMICs were also discussed. Bearing in mind the reported barriers and challenges as well as the disease epidemiology in LMICs, we propose a lean and agile supply chain management framework for improving the accessibility and efficiency of POC diagnostics services in these settings.

  14. Improving the Accessibility and Efficiency of Point-of-Care Diagnostics Services in Low- and Middle-Income Countries: Lean and Agile Supply Chain Management

    Directory of Open Access Journals (Sweden)

    Desmond Kuupiel

    2017-11-01

    Full Text Available Access to point-of-care (POC diagnostics services is essential for ensuring rapid disease diagnosis, management, control, and surveillance. POC testing services can improve access to healthcare especially where healthcare infrastructure is weak and access to quality and timely medical care is a challenge. Improving the accessibility and efficiency of POC diagnostics services, particularly in resource-limited settings, may be a promising route to improving healthcare outcomes. In this review, the accessibility of POC testing is defined as the distance/proximity to the nearest healthcare facility for POC diagnostics service. This review provides an overview of the impact of POC diagnostics on healthcare outcomes in low- and middle-income countries (LMICs and factors contributing to the accessibility of POC testing services in LMICs, focusing on characteristics of the supply chain management and quality systems management, characteristics of the geographical location, health infrastructure, and an enabling policy framework for POC diagnostics services. Barriers and challenges related to the accessibility of POC diagnostics in LMICs were also discussed. Bearing in mind the reported barriers and challenges as well as the disease epidemiology in LMICs, we propose a lean and agile supply chain management framework for improving the accessibility and efficiency of POC diagnostics services in these settings.

  15. [Chronic diarrhea: etiologies and diagnostic evaluation].

    Science.gov (United States)

    Schoepfer, A

    2008-04-30

    Chronic diarrhea is defined as a decrease in fecal consistency lasting for four or more weeks. A myriad of disorders are associated with chronic diarrhea. In developed countries, chronic diarrhea is mostly caused by non-infectious diseases. There are four pathogenic mechanisms leading to chronic diarrhea: osmotic diarrhea, secretory diarrhea, inflammatory diarrhea, and dysmotility. Overlaps between these mechanisms are possible. A 72-hour fecal collection as well as the fasting test are important diagnostic tools to identify the underlying pathomechanism. The identification of the pathomechanism narrows down the possible etiologies of chronic diarrhea and allows therefore a cost-saving diagnostic workup. The endoscopy is well established in the workup of chronic diarrhea. This article gives an overview about the main causes and mechanisms leading to chronic diarrhea and proposes an algorithm for the diagnostic evalution.

  16. Therapy evaluation and diagnostic accuracy in neuroendocrine tumours: assessment of radiological methods

    International Nuclear Information System (INIS)

    Elvin, A.

    1993-01-01

    The diagnostic accuracy of ultrasonically guided biopsy-gun biopsies was assessed in a group of 47 patients with suspected pancreatic carcinoma. A correct diagnosis was obtained in 44 of the 47 patients (94%). Biopsy-gun biopsy of the pancreas is considered a useful, reliable and non-traumatic method for the diagnosis of pancreatic malignancy. Twenty-five patients with known neuroendocrine tumour disease were biopsied with 1.2 mm and 0.9 mm biopsy-gun needles. The influence of treatment-related fibrosis was also evaluated. The overall diagnostic accuracy with the 0.9 mm needle was 69% as compared to 92% with the 1.2 mm needle. In order to assess the diagnostic accuracy rate for radiologists with different experience of biopsy procedures 175 cases of renal biopsy-gun biopsies were evaluated. No statistical significant difference was found between the different operators. The role of duplex Doppler ultrasound in monitoring interferon treatment-related changes in carcinoid metastases was evaluated. It present duplex Doppler ultrasound does not seem to play a role in the evaluation of tumour therapy in carcinoid patients. Therapy response evaluation was performed with MR imaging in a group of 17 patients with neuroendocrine liver metastases. A significant difference was found between patients responding to and patients with failure of treatment in terms of tumour T1, contrast enhancement and signal intensity ratio. This indicates that MR investigation may be used in therapy monitoring of patients with neuroendocrine metastases. The neuroendocrine-differentiated colonic carcinoma cell line (LCC-18) was transplanted to 29 mice to establish a tumour/animal model that would allow the monitoring of changes with MR imaging induced by interferon therapy and to evaluate whether the therapeutic response could be modulated by different interferon dosages. Interferon does not seem to have any prolonged anti-proliferative effect on the LCC-18 tumour cell line when transplanted to

  17. Evaluation of the diagnostic accuracy of the HemoCue device for ...

    African Journals Online (AJOL)

    To assess the validity of the HemoCue in relation to the gold-standard laboratory method. Methods. A cross-sectional study of children aged 6 - 8 years, analysing the diagnostic accuracy of the HemoCue in determining Hb levels in venous blood. Agreement between the HemoCue and laboratory techniques was evaluated ...

  18. Analysis of Vibration Diagnostics Methods for Induction Motors

    Directory of Open Access Journals (Sweden)

    A. P. Kalinov

    2012-01-01

    Full Text Available The paper presents an analysis of existing vibration diagnostics methods. In order to evaluate an efficiency of method application the following criteria have been proposed: volume of input data required for establishing diagnosis, data content, software and hardware level, execution time for vibration diagnostics. According to the mentioned criteria a classification of vibration diagnostics methods for determination of their advantages and disadvantages, search for their development and improvement has been presented in paper. The paper contains a comparative estimation of methods in accordance with the proposed  criteria. According to this estimation the most efficient methods are a spectral analysis and spectral analysis of the vibration signal envelope.

  19. Performance Assessment as a Diagnostic Tool for Science Teachers

    Science.gov (United States)

    Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap

    2018-04-01

    Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.

  20. Evaluate to Improve: Useful Approaches to Student Evaluation

    Science.gov (United States)

    Golding, Clinton; Adam, Lee

    2016-01-01

    Many teachers in higher education use feedback from students to evaluate their teaching, but only some use these evaluations to improve their teaching. One important factor that makes the difference is the teacher's approach to their evaluations. In this article, we identify some useful approaches for improving teaching. We conducted focus groups…

  1. Diagnostic investigation of patients with chronic polyneuropathy: evaluation of a clinical guideline

    NARCIS (Netherlands)

    Rosenberg, N. R.; Portegies, P.; de Visser, M.; Vermeulen, M.

    2001-01-01

    OBJECTIVE: (1) To evaluate a clinical guideline for the diagnostic investigation of patients presenting with signs and symptoms (present for longer than 6 weeks) suggesting a chronic polyneuropathy. (2) To investigate the contribution of electrophysiological studies to a focused search for aetiology

  2. Specialized data analysis for the Space Shuttle Main Engine and diagnostic evaluation of advanced propulsion system components

    Science.gov (United States)

    1993-01-01

    The Marshall Space Flight Center is responsible for the development and management of advanced launch vehicle propulsion systems, including the Space Shuttle Main Engine (SSME), which is presently operational, and the Space Transportation Main Engine (STME) under development. The SSME's provide high performance within stringent constraints on size, weight, and reliability. Based on operational experience, continuous design improvement is in progress to enhance system durability and reliability. Specialized data analysis and interpretation is required in support of SSME and advanced propulsion system diagnostic evaluations. Comprehensive evaluation of the dynamic measurements obtained from test and flight operations is necessary to provide timely assessment of the vibrational characteristics indicating the operational status of turbomachinery and other critical engine components. Efficient performance of this effort is critical due to the significant impact of dynamic evaluation results on ground test and launch schedules, and requires direct familiarity with SSME and derivative systems, test data acquisition, and diagnostic software. Detailed analysis and evaluation of dynamic measurements obtained during SSME and advanced system ground test and flight operations was performed including analytical/statistical assessment of component dynamic behavior, and the development and implementation of analytical/statistical models to efficiently define nominal component dynamic characteristics, detect anomalous behavior, and assess machinery operational condition. In addition, the SSME and J-2 data will be applied to develop vibroacoustic environments for advanced propulsion system components, as required. This study will provide timely assessment of engine component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. This contract will be performed through accomplishment of negotiated task orders.

  3. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  4. The diagnostic work up of growth failure in secondary health care ; An evaluation of consensus guidelines

    NARCIS (Netherlands)

    Grote, F.K.; Oostdijk, W.; Muinck Keizer-Schrama, S.M.P.F. de; Dommelen, P. van; Buuren, S. van; Dekker, F.W.; Ketel, A.G.; Moll, H.A.; Wit, J.M.

    2008-01-01

    Background: As abnormal growth might be the first manifestation of undetected diseases, it is important to have accurate referral criteria and a proper diagnostic work-up. In the present paper we evaluate the diagnostic work-up in secondary health care according to existing consensus guidelines and

  5. Achieving successful evidence-based practice implementation in juvenile justice: The importance of diagnostic and evaluative capacity.

    Science.gov (United States)

    Walker, Sarah Cusworth; Bumbarger, Brian K; Phillippi, Stephen W

    2015-10-01

    Evidence-based programs (EBPs) are an increasingly visible aspect of the treatment landscape in juvenile justice. Research demonstrates that such programs yield positive returns on investment and are replacing more expensive, less effective options. However, programs are unlikely to produce expected benefits when they are not well-matched to community needs, not sustained and do not reach sufficient reach and scale. We argue that achieving these benchmarks for successful implementation will require states and county governments to invest in data-driven decision infrastructure in order to respond in a rigorous and flexible way to shifting political and funding climates. We conceptualize this infrastructure as diagnostic capacity and evaluative capacity: Diagnostic capacity is defined as the process of selecting appropriate programing and evaluative capacity is defined as the ability to monitor and evaluate progress. Policy analyses of Washington State, Pennsylvania and Louisiana's program implementation successes are used to illustrate the benefits of diagnostic and evaluate capacity as a critical element of EBP implementation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. New directions in diagnostic evaluation of insect allergy.

    Science.gov (United States)

    Golden, David B K

    2014-08-01

    Diagnosis of insect sting allergy and prediction of risk of sting anaphylaxis are often difficult because tests for venom-specific IgE antibodies have a limited positive predictive value and do not reliably predict the severity of sting reactions. Component-resolved diagnosis using recombinant venom allergens has shown promise in improving the specificity of diagnostic testing for insect sting allergy. Basophil activation tests have been explored as more sensitive assays for identification of patients with insect allergy and for prediction of clinical outcomes. Measurement of mast cell mediators reflects the underlying risk for more severe reactions and limited clinical response to treatment. Measurement of IgE to recombinant venom allergens can distinguish cross-sensitization from dual sensitization to honeybee and vespid venoms, thus helping to limit venom immunotherapy to a single venom instead of multiple venoms in many patients. Basophil activation tests can detect venom allergy in patients who show no detectable venom-specific IgE in standard diagnostic tests and can predict increased risk of systemic reactions to venom immunotherapy, and to stings during and after stopping venom immunotherapy. The risk of severe or fatal anaphylaxis to stings can also be predicted by measurement of baseline serum tryptase or other mast cell mediators.

  7. A comprehensive custom panel design for routine hereditary cancer testing: preserving control, improving diagnostics and revealing a complex variation landscape.

    Science.gov (United States)

    Castellanos, Elisabeth; Gel, Bernat; Rosas, Inma; Tornero, Eva; Santín, Sheila; Pluvinet, Raquel; Velasco, Juan; Sumoy, Lauro; Del Valle, Jesús; Perucho, Manuel; Blanco, Ignacio; Navarro, Matilde; Brunet, Joan; Pineda, Marta; Feliubadaló, Lidia; Capellá, Gabi; Lázaro, Conxi; Serra, Eduard

    2017-01-04

    We wanted to implement an NGS strategy to globally analyze hereditary cancer with diagnostic quality while retaining the same degree of understanding and control we had in pre-NGS strategies. To do this, we developed the I2HCP panel, a custom bait library covering 122 hereditary cancer genes. We improved bait design, tested different NGS platforms and created a clinically driven custom data analysis pipeline. The I2HCP panel was developed using a training set of hereditary colorectal cancer, hereditary breast and ovarian cancer and neurofibromatosis patients and reached an accuracy, analytical sensitivity and specificity greater than 99%, which was maintained in a validation set. I2HCP changed our diagnostic approach, involving clinicians and a genetic diagnostics team from panel design to reporting. The new strategy improved diagnostic sensitivity, solved uncertain clinical diagnoses and identified mutations in new genes. We assessed the genetic variation in the complete set of hereditary cancer genes, revealing a complex variation landscape that coexists with the disease-causing mutation. We developed, validated and implemented a custom NGS-based strategy for hereditary cancer diagnostics that improved our previous workflows. Additionally, the existence of a rich genetic variation in hereditary cancer genes favors the use of this panel to investigate their role in cancer risk.

  8. Towards improving the safety and diagnostic yield of stereotactic biopsy in a single centre

    NARCIS (Netherlands)

    R. Dammers (Ruben); J.W. Schouten (Joost); I. Haitsma (Iain); A.J.P.E. Vincent (Arnoud); J.M. Kros (Johan); C.M.F. Dirven (Clemens)

    2010-01-01

    textabstractBackground: Previously, we reported on our single centre results regarding the diagnostic yield of stereotactic needle biopsies of brain lesions. The yield then (1996-2006) was 89.4%. In the present study, we review and evaluate our experience with intraoperative frozen-section

  9. Air quality modeling for accountability research: Operational, dynamic, and diagnostic evaluation

    Science.gov (United States)

    Henneman, Lucas R. F.; Liu, Cong; Hu, Yongtao; Mulholland, James A.; Russell, Armistead G.

    2017-10-01

    Photochemical grid models play a central role in air quality regulatory frameworks, including in air pollution accountability research, which seeks to demonstrate the extent to which regulations causally impacted emissions, air quality, and public health. There is a need, however, to develop and demonstrate appropriate practices for model application and evaluation in an accountability framework. We employ a combination of traditional and novel evaluation techniques to assess four years (2001-02, 2011-12) of simulated pollutant concentrations across a decade of major emissions reductions using the Community Multiscale Air Quality (CMAQ) model. We have grouped our assessments in three categories: Operational evaluation investigates how well CMAQ captures absolute concentrations; dynamic evaluation investigates how well CMAQ captures changes in concentrations across the decade of changing emissions; diagnostic evaluation investigates how CMAQ attributes variability in concentrations and sensitivities to emissions between meteorology and emissions, and how well this attribution compares to empirical statistical models. In this application, CMAQ captures O3 and PM2.5 concentrations and change over the decade in the Eastern United States similarly to past CMAQ applications and in line with model evaluation guidance; however, some PM2.5 species-EC, OC, and sulfate in particular-exhibit high biases in various months. CMAQ-simulated PM2.5 has a high bias in winter months and low bias in the summer, mainly due to a high bias in OC during the cold months and low bias in OC and sulfate during the summer. Simulated O3 and PM2.5 changes across the decade have normalized mean bias of less than 2.5% and 17%, respectively. Detailed comparisons suggest biased EC emissions, negative wintertime SO42- sensitivities to mobile source emissions, and incomplete capture of OC chemistry in the summer and winter. Photochemical grid model-simulated O3 and PM2.5 responses to emissions and

  10. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  11. Improved detection of Burkholderia pseudomallei from non-blood clinical specimens using enrichment culture and PCR: narrowing diagnostic gap in resource-constrained settings.

    Science.gov (United States)

    Tellapragada, Chaitanya; Shaw, Tushar; D'Souza, Annet; Eshwara, Vandana Kalwaje; Mukhopadhyay, Chiranjay

    2017-07-01

    To evaluate the diagnostic utility of enrichment culture and PCR for improved case detection rates of non-bacteraemic form of melioidosis in limited resource settings. Clinical specimens (n = 525) obtained from patients presenting at a tertiary care hospital of South India with clinical symptoms suggestive of community-acquired pneumonia, lower respiratory tract infections, superficial or internal abscesses, chronic skin ulcers and bone or joint infections were tested for the presence of Burkholderia pseudomallei using conventional culture (CC), enrichment culture (EC) and PCR. Sensitivity, specificity, positive and negative predictive values of CC and PCR were initially deduced using EC as the gold standard method. Further, diagnostic accuracies of all the three methods were analysed using Bayesian latent class modelling (BLCM). Detection rates of B. pseudomallei using CC, EC and PCR were 3.8%, 5.3% and 6%, respectively. Diagnostic sensitivities and specificities of CC and PCR were 71.4, 98.4% and 100 and 99.4%, respectively in comparison with EC as the gold standard test. With Bayesian latent class modelling, EC and PCR demonstrated sensitivities of 98.7 and 99.3%, respectively, while CC showed a sensitivity of 70.3% for detection of B. pseudomallei. An increase of 1.6% (95% CI: 1.08-4.32%) in the case detection rate of melioidosis was observed in the study population when EC and/or PCR were used in adjunct to the conventional culture technique. Our study findings underscore the diagnostic superiority of enrichment culture and/or PCR over conventional microbiological culture for improved case detection of melioidosis from non-blood clinical specimens. © 2017 John Wiley & Sons Ltd.

  12. Diagnostic accuracy of routine blood examinations and CSF lactate level for post-neurosurgical bacterial meningitis.

    Science.gov (United States)

    Zhang, Yang; Xiao, Xiong; Zhang, Junting; Gao, Zhixian; Ji, Nan; Zhang, Liwei

    2017-06-01

    To evaluate the diagnostic accuracy of routine blood examinations and Cerebrospinal Fluid (CSF) lactate level for Post-neurosurgical Bacterial Meningitis (PBM) at a large sample-size of post-neurosurgical patients. The diagnostic accuracies of routine blood examinations and CSF lactate level to distinguish between PAM and PBM were evaluated with the values of the Area Under the Curve of the Receiver Operating Characteristic (AUC -ROC ) by retrospectively analyzing the datasets of post-neurosurgical patients in the clinical information databases. The diagnostic accuracy of routine blood examinations was relatively low (AUC -ROC CSF lactate level achieved rather high diagnostic accuracy (AUC -ROC =0.891; CI 95%, 0.852-0.922). The variables of patient age, operation duration, surgical diagnosis and postoperative days (the interval days between the neurosurgery and examinations) were shown to affect the diagnostic accuracy of these examinations. The variables were integrated with routine blood examinations and CSF lactate level by Fisher discriminant analysis to improve their diagnostic accuracy. As a result, the diagnostic accuracy of blood examinations and CSF lactate level was significantly improved with an AUC -ROC value=0.760 (CI 95%, 0.737-0.782) and 0.921 (CI 95%, 0.887-0.948) respectively. The PBM diagnostic accuracy of routine blood examinations was relatively low, whereas the accuracy of CSF lactate level was high. Some variables that are involved in the incidence of PBM can also affect the diagnostic accuracy for PBM. Taking into account the effects of these variables significantly improves the diagnostic accuracies of routine blood examinations and CSF lactate level. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    Science.gov (United States)

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  14. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  15. Does improved access to diagnostic imaging results reduce hospital length of stay? A retrospective study

    Directory of Open Access Journals (Sweden)

    Hurlen Petter

    2010-09-01

    Full Text Available Abstract Background One year after the introduction of Information and Communication Technology (ICT to support diagnostic imaging at our hospital, clinicians had faster and better access to radiology reports and images; direct access to Computed Tomography (CT reports in the Electronic Medical Record (EMR was particularly popular. The objective of this study was to determine whether improvements in radiology reporting and clinical access to diagnostic imaging information one year after the ICT introduction were associated with a reduction in the length of patients' hospital stays (LOS. Methods Data describing hospital stays and diagnostic imaging were collected retrospectively from the EMR during periods of equal duration before and one year after the introduction of ICT. The post-ICT period was chosen because of the documented improvement in clinical access to radiology results during that period. The data set was randomly split into an exploratory part used to establish the hypotheses, and a confirmatory part. The data was used to compare the pre-ICT and post-ICT status, but also to compare differences between groups. Results There was no general reduction in LOS one year after ICT introduction. However, there was a 25% reduction for one group - patients with CT scans. This group was heterogeneous, covering 445 different primary discharge diagnoses. Analyses of subgroups were performed to reduce the impact of this divergence. Conclusion Our results did not indicate that improved access to radiology results reduced the patients' LOS. There was, however, a significant reduction in LOS for patients undergoing CT scans. Given the clinicians' interest in CT reports and the results of the subgroup analyses, it is likely that improved access to CT reports contributed to this reduction.

  16. Benchmarking Diagnostic Algorithms on an Electrical Power System Testbed

    Science.gov (United States)

    Kurtoglu, Tolga; Narasimhan, Sriram; Poll, Scott; Garcia, David; Wright, Stephanie

    2009-01-01

    Diagnostic algorithms (DAs) are key to enabling automated health management. These algorithms are designed to detect and isolate anomalies of either a component or the whole system based on observations received from sensors. In recent years a wide range of algorithms, both model-based and data-driven, have been developed to increase autonomy and improve system reliability and affordability. However, the lack of support to perform systematic benchmarking of these algorithms continues to create barriers for effective development and deployment of diagnostic technologies. In this paper, we present our efforts to benchmark a set of DAs on a common platform using a framework that was developed to evaluate and compare various performance metrics for diagnostic technologies. The diagnosed system is an electrical power system, namely the Advanced Diagnostics and Prognostics Testbed (ADAPT) developed and located at the NASA Ames Research Center. The paper presents the fundamentals of the benchmarking framework, the ADAPT system, description of faults and data sets, the metrics used for evaluation, and an in-depth analysis of benchmarking results obtained from testing ten diagnostic algorithms on the ADAPT electrical power system testbed.

  17. Analysis of prostate cancer localization toward improved diagnostic accuracy of transperineal prostate biopsy

    Directory of Open Access Journals (Sweden)

    Yoshiro Sakamoto

    2014-09-01

    Conclusions: The concordance of prostate cancer between prostatectomy specimens and biopsies is comparatively favorable. According to our study, the diagnostic accuracy of transperineal prostate biopsy can be improved in our institute by including the anterior portion of the Apex-Mid and Mid regions in the 12-core biopsy or 16-core biopsy, such that a 4-core biopsy of the anterior portion is included.

  18. Evaluation of dimensions of diagnostic X-ray tube focal spots using direct digitalization

    International Nuclear Information System (INIS)

    Costa, Paulo R.; Furquim, Tania A.C.

    1996-01-01

    An image digitalization system is proposed as an alternative method for replacing direct exposure X-ray films on the evaluation of dimensions of diagnostic X-ray tube focal spots. Results of measurements are presented and compared to nominal values

  19. NIF diagnostic damage and design issues

    International Nuclear Information System (INIS)

    Landen, N.

    1999-01-01

    The NIF target environment is evaluated with respect to target and diagnostic debris and with respect to instrument survivability in the presence of target debris and radiation. Quantitative estimates are arrived at by extrapolating from Nova and Omega experience using simple scaling arguments. Specifically, we evaluate the closest distance of approach of various components of DIM-based diagnostics such as target mounted pinhole arrays, open detectors, filters, x-ray optics, and spectrometers. We also include constraints on achieving adequate signal-to-noise on x-ray diagnostics. Four of the most important conclusions are as follows: (1) The required full NIF stand-off distance for heavily filtered detectors (e.g. multi-keV x-ray and particle detectors) as determined by concerns of diagnostic debris and diagnostic survivability to debris and radiation is no more than 100 cm. (2) Target mounted pinhole arrays and slits mounted a few cm from chamber center at NIF will survive long enough to record data and should be an acceptable source of shrapnel debris. (3) DIM-based instrument stand-off distances are compatible with achieving the same photon statistics (or better with ongoing improvements in detector resolution and noise) than available with current Nova and Omega SIM- or TIM-based instrumentation. Section II reviews target and diagnostic debris with respect to final optics. Section III reviews debris and radiation with respect to all diagnostic components. The following laser scaling between Nova/Omega and NIF is used throughout unless otherwise specified: laser energy E = 100x, drive duration τ = 6x and hence for a given laser intensity or hohlraum temperature, target size r approximately √(E/τ) = 4x. The 100x increase in E accounts for the fact that many Nova shots were performed with only 20 kJ and all LLNL Omega shots were performed with only 15 kJ

  20. Optimization of Classification Strategies of Acetowhite Temporal Patterns towards Improving Diagnostic Performance of Colposcopy

    Directory of Open Access Journals (Sweden)

    Karina Gutiérrez-Fragoso

    2017-01-01

    Full Text Available Efforts have been being made to improve the diagnostic performance of colposcopy, trying to help better diagnose cervical cancer, particularly in developing countries. However, improvements in a number of areas are still necessary, such as the time it takes to process the full digital image of the cervix, the performance of the computing systems used to identify different kinds of tissues, and biopsy sampling. In this paper, we explore three different, well-known automatic classification methods (k-Nearest Neighbors, Naïve Bayes, and C4.5, in addition to different data models that take full advantage of this information and improve the diagnostic performance of colposcopy based on acetowhite temporal patterns. Based on the ROC and PRC area scores, the k-Nearest Neighbors and discrete PLA representation performed better than other methods. The values of sensitivity, specificity, and accuracy reached using this method were 60% (95% CI 50–70, 79% (95% CI 71–86, and 70% (95% CI 60–80, respectively. The acetowhitening phenomenon is not exclusive to high-grade lesions, and we have found acetowhite temporal patterns of epithelial changes that are not precancerous lesions but that are similar to positive ones. These findings need to be considered when developing more robust computing systems in the future.

  1. Does Sex Influence the Diagnostic Evaluation of Autism Spectrum Disorder in Adults?

    Science.gov (United States)

    Wilson, C. Ellie; Murphy, Clodagh M.; McAlonan, Grainne; Robertson, Dene M.; Spain, Debbie; Hayward, Hannah; Woodhouse, Emma; Deeley, P. Quinton; Gillan, Nicola; Ohlsen, J. Chris; Zinkstok, Janneke; Stoencheva, Vladimira; Faulkner, Jessica; Yildiran, Hatice; Bell, Vaughan; Hammond, Neil; Craig, Michael C.; Murphy, Declan G. M.

    2016-01-01

    It is unknown whether sex influences the diagnostic evaluation of autism spectrum disorder, or whether male and female adults within the spectrum have different symptom profiles. This study reports sex differences in clinical outcomes for 1,244 adults (935 males and 309 females) referred for autism spectrum disorder assessment. Significantly, more…

  2. The pilot evaluation for the National Evaluation System in South Africa – A diagnostic review of early childhood development

    Directory of Open Access Journals (Sweden)

    Margot Davids

    2015-10-01

    Full Text Available Policymaking in many instances does not follow proper diagnosis of a problem using evidence to justify why particular decisions have been taken. This article describes findings of a diagnostic review of existing challenges facing early childhood development (ECD in South Africa. The review is part of the government’s attempt to use information to drive policy in strategic areas. It is part of the role that the Presidency is seeking to play in ensuring government programmes are evaluated to ensure that money that is spent is spent on programmes that have an impact and that there is value for money. This article summarises the key findings of the diagnostic review that was conducted of policy, services and coordination.The results reveal that a broader definition of ECD programmes is needed to cover all aspects of children’s development, growth and health, from conception to the foundation phase of schooling. Many elements of comprehensive ECD support and services are already in place and some are performing well. However, there are important gaps. Key ECD strategies for the future are identified. The diagnostic evaluation used a variety of methods, including desktop analysis, interviews and data analysis. Issues emerged around how to link the evaluation with other processes in the involved departments. A particular challenge was how to handle the transition to implementation of the findings, as responsibility shifted from the steering committee to the departments. The process worked well despite past challenges with coordination across government.

  3. Evaluation of diagnostic quality in musculoskeletal three-dimensional CT scans

    International Nuclear Information System (INIS)

    Vannier, M.W.; Hildebolt, C.F.; Gilula, L.A.; Sutherland, C.J.; Offutt, C.J.; Drebin, R.; Mantle, M.; Giordono, T.A.

    1988-01-01

    A major application of three-dimensional computed tomography (CT) is in the imaging of the skeleton. Three-dimensional CT has an important role in determining the presence and extent of congenital and acquired orthopedic abnormalities. The objective of this study was to compare the diagnostic sensitivity and specificity of three-dimensional CT, planar CT, and plain radiography in the detection and characterization of orthopedic abnormalities. Three-dimensional CT scan reconstructions were obtained by two methods, surface reconstruction and volumetric techniques. Seventy patients were imaged with CT, three-dimensional CT, and plain radiography. The consensus opinion of experts with access to all images plus clinical history, surgical findings, and follow-up findings were taken as truth. Expert radiologists read these cases in a blinded fashion. The results were compared using receiver operating characteristic (ROC) analysis. The diagnostic value of each three-dimensional reconstruction method and the parameters used to perform the reconstructions were evaluated

  4. The Increase of Operational Safety of Ships by Improving Diagnostic Methods for Marine Diesel Engine

    Directory of Open Access Journals (Sweden)

    Kazimierz Witkowski

    2017-06-01

    Full Text Available This article shows the importance of the diagnostic improvement methods of marine engines to boost the economy and safety of operation of marine cargo ships. The need to implement effective diagnostic methods is justified by presenting statistical data of marine diesel engines failure and the cost of their operation. Based on the own research has been proven, for the chosen example, that indicator diagrams and analysis of indicated parameters have limited utility in the diagnosis of damages of marine engine, although this is a method commonly used in operational practice. To achieve greater diagnostic effectiveness, when, based on indicator diagrams, are calculated and then the characteristics of heat release is analyzed - net of heat release characteristics and the intensity of the heat release, it was demonstrated. This procedure is particularly effective in the diagnosis of damage of injection system components marine diesel engine.

  5. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    Science.gov (United States)

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA

  6. Integration of interactive three-dimensional image post-processing software into undergraduate radiology education effectively improves diagnostic skills and visual-spatial ability.

    Science.gov (United States)

    Rengier, Fabian; Häfner, Matthias F; Unterhinninghofen, Roland; Nawrotzki, Ralph; Kirsch, Joachim; Kauczor, Hans-Ulrich; Giesel, Frederik L

    2013-08-01

    Integrating interactive three-dimensional post-processing software into undergraduate radiology teaching might be a promising approach to synergistically improve both visual-spatial ability and radiological skills, thereby reducing students' deficiencies in image interpretation. The purpose of this study was to test our hypothesis that a hands-on radiology course for medical students using interactive three-dimensional image post-processing software improves radiological knowledge, diagnostic skills and visual-spatial ability. A hands-on radiology course was developed using interactive three-dimensional image post-processing software. The course consisted of seven seminars held on a weekly basis. The 25 participating fourth- and fifth-year medical students learnt to systematically analyse cross-sectional imaging data and correlated the two-dimensional images with three-dimensional reconstructions. They were instructed by experienced radiologists and collegiate tutors. The improvement in radiological knowledge, diagnostic skills and visual-spatial ability was assessed immediately before and after the course by multiple-choice tests comprising 64 questions each. Wilcoxon signed rank test for paired samples was applied. The total number of correctly answered questions improved from 36.9±4.8 to 49.5±5.4 (pability by 11.3% (psoftware into undergraduate radiology education effectively improves radiological reasoning, diagnostic skills and visual-spatial ability, and thereby even diagnostic skills for imaging modalities not included in the course. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  8. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  9. Validation of proposed diagnostic criteria (the "Budapest Criteria") for Complex Regional Pain Syndrome.

    Science.gov (United States)

    Harden, R Norman; Bruehl, Stephen; Perez, Roberto S G M; Birklein, Frank; Marinus, Johan; Maihofner, Christian; Lubenow, Timothy; Buvanendran, Asokumar; Mackey, Sean; Graciosa, Joseph; Mogilevski, Mila; Ramsden, Christopher; Chont, Melissa; Vatine, Jean-Jacques

    2010-08-01

    Current IASP diagnostic criteria for CRPS have low specificity, potentially leading to overdiagnosis. This validation study compared current IASP diagnostic criteria for CRPS to proposed new diagnostic criteria (the "Budapest Criteria") regarding diagnostic accuracy. Structured evaluations of CRPS-related signs and symptoms were conducted in 113 CRPS-I and 47 non-CRPS neuropathic pain patients. Discriminating between diagnostic groups based on presence of signs or symptoms meeting IASP criteria showed high diagnostic sensitivity (1.00), but poor specificity (0.41), replicating prior work. In comparison, the Budapest clinical criteria retained the exceptional sensitivity of the IASP criteria (0.99), but greatly improved upon the specificity (0.68). As designed, the Budapest research criteria resulted in the highest specificity (0.79), again replicating prior work. Analyses indicated that inclusion of four distinct CRPS components in the Budapest Criteria contributed to enhanced specificity. Overall, results corroborate the validity of the Budapest Criteria and suggest they improve upon existing IASP diagnostic criteria for CRPS. Copyright (c) 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  10. A web-based test of residents' skills in diagnostic radiology

    International Nuclear Information System (INIS)

    Finlay, K.; Norman, G.R.; Keane, D.R.; Stolberg, H.

    2006-01-01

    To develop an objective, Web-based tool for evaluating residents' knowledge of diagnostic radiology. We developed and tested a Web-based evaluation tool (the Diagnostic Radiology Skills Test) that consists of 3 tests, one in each of 3 domains of diagnostic radiology: chest, gastrointestinal, and musculoskeletal imaging. Each test comprises 30 cases representing a range of difficulty in the domain, including normal states, normal variants, typical cases of common diagnoses, and cases with more subtle findings. Cases are presented with a long menu of domain-specific possible diagnoses (response options), each coded for diagnostic appropriateness. Our subjects were 21 residents in postgraduate year (PGY) 2 to 5 and 11 experts in diagnostic radiology. Subjects accessed the tool via a Web site on our Web server. Residents test results were compared for reliability and validity across domain, case, and training level. In addition, results were correlated with commonly used established and objective evaluation tools. The tool demonstrated consistent monotonic improvement in performance with training level. It showed acceptable reliability in discriminating between residents at different performance levels, both within and across training levels (r = 0.53 within level and 0.69 across levels). Test results also had concurrent validity against the American College of Radiology In-Training Examination, a widely accepted objective assessment tool (r = 0.65, P < 0.01), and 2 Objective Structured Clinical Examinations (OSCEs) focusing on diagnostic skills (r = 0.78 and r 0.69, P < 0.01, respectively). Our study demonstrates the feasibility of a Web-based, standardized, objective assessment method for evaluating residents' performance. (author)

  11. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  12. Inductive foraging: improving the diagnostic yield of primary care consultations.

    Science.gov (United States)

    Donner-Banzhoff, Norbert; Hertwig, Ralph

    2014-03-01

    Physicians attempting to make a diagnosis arrive at specific hypotheses early in their encounter with patients. Further data are collected in the light of these early hypotheses. While this hypothetico-deductive model has been accepted as both a description of physicians' data gathering and a norm, little attention has been paid to the preceding stage of the consultation. It is suggested that 'inductive foraging' is a relevant and appropriate mode of data acquisition for the first part of the patient encounter. Research evidence from cognitive psychology and medical reasoning research is discussed. With inductive foraging, 'pattern failure' rather than 'pattern recognition' is the mode of discovery. Largely, guidance should be left to the patient to lead the clinician into areas where departures from normality are to be found. This is in contrast to active and focused 'deductive inquiry,' which should be used only after most aetiologies, but a few have eliminated. Especially when the prevalence of serious disease is low, and a wide range of diagnoses must be evaluated, such as in General Practice, inductive foraging is a rational and efficient diagnostic strategy. Previously, too little attention has been paid to the initial stage of the consultation. Premature closure at this point may result in diagnostic error.

  13. An index with improved diagnostic accuracy for the diagnosis of Crohn's disease derived from the Lennard-Jones criteria.

    Science.gov (United States)

    Reinisch, S; Schweiger, K; Pablik, E; Collet-Fenetrier, B; Peyrin-Biroulet, L; Alfaro, I; Panés, J; Moayyedi, P; Reinisch, W

    2016-09-01

    The Lennard-Jones criteria are considered the gold standard for diagnosing Crohn's disease (CD) and include the items granuloma, macroscopic discontinuity, transmural inflammation, fibrosis, lymphoid aggregates and discontinuous inflammation on histology. The criteria have never been subjected to a formal validation process. To develop a validated and improved diagnostic index based on the items of Lennard-Jones criteria. Included were 328 adult patients with long-standing CD (median disease duration 10 years) from three centres and classified as 'established', 'probable' or 'non-CD' by Lennard-Jones criteria at time of diagnosis. Controls were patients with ulcerative colitis (n = 170). The performance of each of the six diagnostic items of Lennard-Jones criteria was modelled by logistic regression and a new index based on stepwise backward selection and cut-offs was developed. The diagnostic value of the new index was analysed by comparing sensitivity, specificity and accuracy vs. Lennard-Jones criteria. By Lennard-Jones criteria 49% (n = 162) of CD patients would have been diagnosed as 'non-CD' at time of diagnosis (sensitivity/specificity/accuracy, 'established' CD: 0.34/0.99/0.67; 'probable' CD: 0.51/0.95/0.73). A new index was derived from granuloma, fibrosis, transmural inflammation and macroscopic discontinuity, but excluded lymphoid aggregates and discontinuous inflammation on histology. Our index provided improved diagnostic accuracy for 'established' and 'probable' CD (sensitivity/specificity/accuracy, 'established' CD: 0.45/1/0.72; 'probable' CD: 0.8/0.85/0.82), including the subgroup isolated colonic CD ('probable' CD, new index: 0.73/0.85/0.79; Lennard-Jones criteria: 0.43/0.95/0.69). We developed an index based on items of Lennard-Jones criteria providing improved diagnostic accuracy for the differential diagnosis between CD and UC. © 2016 John Wiley & Sons Ltd.

  14. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    Science.gov (United States)

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  15. Structured diagnostic imaging in patients with multiple trauma

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Rieger, J.; Rock, C.; Pfeifer, K.J.; Reiser, M.; Kanz, K.G.

    2002-01-01

    Purpose. Development of a concept for structured diagnostic imaging in patients with multiple trauma.Material and methods. Evaluation of data from a prospective trial with over 2400 documented patients with multiple trauma. All diagnostic and therapeutic steps, primary and secondary death and the 90 days lethality were documented.Structured diagnostic imaging of multiple injured patients requires the integration of an experienced radiologist in an interdisciplinary trauma team consisting of anesthesia, radiology and trauma surgery. Radiology itself deserves standardized concepts for equipment, personnel and logistics to perform diagnostic imaging for a 24-h-coverage with constant quality.Results. This paper describes criteria for initiation of a shock room or emergency room treatment, strategies for documentation and interdisciplinary algorithms for the early clinical care coordinating diagnostic imaging and therapeutic procedures following standardized guidelines. Diagnostic imaging consists of basic diagnosis, radiological ABC-rule, radiological follow-up and structured organ diagnosis using CT. Radiological trauma scoring allows improved quality control of diagnosis and therapy of multiple injured patients.Conclusion. Structured diagnostic imaging of multiple injured patients leads to a standardization of diagnosis and therapy and ensures constant process quality. (orig.) [de

  16. Recent improvements of the JET lithium beam diagnostic.

    Science.gov (United States)

    Brix, M; Dodt, D; Dunai, D; Lupelli, I; Marsen, S; Melson, T F; Meszaros, B; Morgan, P; Petravich, G; Refy, D I; Silva, C; Stamp, M; Szabolics, T; Zastrow, K-D; Zoletnik, S

    2012-10-01

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  17. The improvement of diagnostic and therapeutic imaging in Africa

    International Nuclear Information System (INIS)

    2015-02-01

    The 8. Pan-African Congress of Radiology and Imaging on the improvement of diagnostic and therapeutic imaging in Africa was hosted in Nairobi Kenya. The conference focusses on Review of Radiation Safety in Medical X-Ray Diagnosis, Medical Practitioners of Radiology & Imaging in the Dock. It also addresses issues Knowledge, Attitude, and Practice of Clinicians, Practicing at the Kenyatta National Hospital on Ionizing Radiation and Procurement in the Imaging Department. The Need for Understanding Technical Specifications,Students Experience in Radiography, Radioiodine Therapy for Graves’ Disease, Role of ultrasound in the diagnosis and management of gestational trophoblastic disease in Rural health facilities were areas interest. Diabetes Mellitus and the Musculoskeletal System, Imaging the Traumatized Spine ‘Clearing the Cervical Spine’, The Radiation Safety Culture: Image Gently and Radiation Protection of the Young Patient: Kenya perspective were discussed during the conference

  18. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform.

    Science.gov (United States)

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B; Nauwelaers, David; Ariën, Kevin K

    2016-10-15

     The 2013-2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV).  The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus.  The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%.  The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  19. Survivors of early childhood trauma: evaluating a two-dimensional diagnostic model of the impact of trauma and neglect

    Directory of Open Access Journals (Sweden)

    Marleen Wildschut

    2014-04-01

    Full Text Available Background: A two-dimensional diagnostic model for (complex trauma-related and personality disorders has been proposed to assess the severity and prognosis of the impact of early childhood trauma and emotional neglect. An important question that awaits empirical examination is whether a distinction between trauma-related disorders and personality disorders reflects reality when focusing on survivors of early childhood trauma. And, is a continuum of trauma diagnoses a correct assumption and, if yes, what does it look like? Objective: We describe the design of a cross-sectional cohort study evaluating this two-dimensional model of the impact of trauma and neglect. To provide the rationale of our study objectives, we review the existing literature on the impact of early childhood trauma and neglect on trauma-related disorders and personality disorders. Aims of the study are to: (1 quantify the two-dimensional model and test the relation with trauma and neglect; and (2 compare the two study groups. Method: A total of 200 consecutive patients referred to two specific treatment programs (100 from a personality disorder program and 100 from a trauma-related disorder program in the north of Holland will be included. Data are collected at the start of treatment. The assessments include all DSM-5 trauma-related and personality disorders, and general psychiatric symptoms, trauma history, and perceived emotional neglect. Discussion: The results will provide an evaluation of the model and an improvement of the understanding of the relationship between trauma-related disorders and personality disorders and early childhood trauma and emotional neglect. This may improve both diagnostic as well as indication procedures. We will discuss possible strengths and limitations of the design.

  20. Evaluation of endourological tools to improve the diagnosis and therapy of ureteral tumors – from model development to clinical application

    Directory of Open Access Journals (Sweden)

    Wagner D.

    2015-09-01

    Full Text Available Adequate diagnosis of upper urinary tract (UUT tumors is essential for successful local treatment. Organsparing approaches are technically difficult and require consistent further development. Appropriate models for investigating new diagnostic and therapeutic methods are not yet available. This study demonstrates the incorporation of a fresh sample model into five different test levels (I-V for improving the diagnosis and therapy of ureteral tumors. In these test levels, new diagnostic and ablation techniques are evaluated for feasibility, application safety, efficacy and accuracy. An assessment of their suitability for broad preclinical and clinical application also took economic aspects into account.

  1. Three-dimensional textural features of conventional MRI improve diagnostic classification of childhood brain tumours.

    Science.gov (United States)

    Fetit, Ahmed E; Novak, Jan; Peet, Andrew C; Arvanitits, Theodoros N

    2015-09-01

    The aim of this study was to assess the efficacy of three-dimensional texture analysis (3D TA) of conventional MR images for the classification of childhood brain tumours in a quantitative manner. The dataset comprised pre-contrast T1 - and T2-weighted MRI series obtained from 48 children diagnosed with brain tumours (medulloblastoma, pilocytic astrocytoma and ependymoma). 3D and 2D TA were carried out on the images using first-, second- and higher order statistical methods. Six supervised classification algorithms were trained with the most influential 3D and 2D textural features, and their performances in the classification of tumour types, using the two feature sets, were compared. Model validation was carried out using the leave-one-out cross-validation (LOOCV) approach, as well as stratified 10-fold cross-validation, in order to provide additional reassurance. McNemar's test was used to test the statistical significance of any improvements demonstrated by 3D-trained classifiers. Supervised learning models trained with 3D textural features showed improved classification performances to those trained with conventional 2D features. For instance, a neural network classifier showed 12% improvement in area under the receiver operator characteristics curve (AUC) and 19% in overall classification accuracy. These improvements were statistically significant for four of the tested classifiers, as per McNemar's tests. This study shows that 3D textural features extracted from conventional T1 - and T2-weighted images can improve the diagnostic classification of childhood brain tumours. Long-term benefits of accurate, yet non-invasive, diagnostic aids include a reduction in surgical procedures, improvement in surgical and therapy planning, and support of discussions with patients' families. It remains necessary, however, to extend the analysis to a multicentre cohort in order to assess the scalability of the techniques used. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. The experiences of health-related quality of life in patients with nonspecific symptoms who undergo a diagnostic evaluation for cancer

    DEFF Research Database (Denmark)

    Moseholm, Ellen; Lindhardt, Bjarne Oerskov; Rydahl-Hansen, Susan

    2017-01-01

    The diagnostic phase of cancer can affect health-related quality of life (HRQoL). The aim of this study was to investigate how patients with nonspecific symptoms experience HRQoL while undergoing diagnostic evaluations for cancer. Twenty-one participants who had completed a fast-track evaluation...... of Cancer Quality of Life questionnaire (EORCT-QLQ-C30). Data analysis was based on qualitative content analysis by Krippendorff. The analysis generated six categories: symptoms, physical-, role-, emotional-, cognitive- and social functioning, and the diagnostic fast-track experience. From these categories......, a main theme was identified: Health-related quality of life is not solely affected by the diagnostic process. The results provide a comprehensive understanding of HRQoL in the diagnostic phase of possible cancer, which can be used not only to enhance evidence-based care, but also in the interpretation...

  4. Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

    Energy Technology Data Exchange (ETDEWEB)

    Bjarnason, Thorarin [Diagnostic Imaging / Interior Health, Mathematics, Statistics, Physics & Computer Science / UBCO (Canada); Radiology / UBC (Canada)

    2016-08-15

    Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

  5. Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

    International Nuclear Information System (INIS)

    Bjarnason, Thorarin

    2016-01-01

    Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

  6. Diagnostic Evaluation of Effective Thyroxine Ratio

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Choi, Sang Jae; Ro, Heung Kyu; Lee, Hong Kyu; Koh, Chang Soon; Lee, Mun Ho

    1975-01-01

    The purpose of the present study is to evaluate the diagnostic value of the ETR test as compared to other thyroid function tests in normal persons, patients with thyroid disorders and patients with alterations of thyroxine-binding proteins. The ETR values were obtained from 35 cases as normal control, 63 hyperthyroid patients, 56 euthyroid patients, 23 hypothyroid patients, 10 pregnant women, 5 women taking oral contraceptive medication, 8 liver cirrhosis patients and 4 nephrotic syndrome patients. The results obtained were as follows. 1) The mean value of ETR obtained from the normal controls was 0.99±0.06. 2) The mean ETR values of various thyroid states were 1.25±0.16 in hyperthyroidism, 0.99±0.08 in euthyroidism and 0.82±0.05 in hypothyroidism and significant difference was found between these groups. 3) Seven out of 63 hyperthyroid patients (11.1%) and 2 out of 23 hypothyroid patients (8.7%) had ETR values within normal range and among the 56 euthyroid patients 6 (10.7%) had ETR values outside normal range, so the diagnostic compatibility of ETR was 89.4% in thyroid diseases. 4) Even though the ETR value was well correlated with 131 I-thyroid uptake rate, serum T 3 resin uptake rate and serum T 4 , a high positive correlation was found (r=0.79) between ETR and T 7 . 5) The mean ETR values from patients with alteration in TBG binding capacity were 0.99±0.05 in pregnant women, 0.98±0.04 in women with oral contraceptive medication, 1.04±0.09 in liver cirrhosis patients and 0.94±0.02 in nephrotic syndrome patients and most of them (85.2%) had ETR values within normal range. Our results, therefore, suggests that the ETR estimation does offer the simplest and most reliable single procedure for the screening and diagnosis of various thyroid diseases as a indirect indicator of serum-free thyroxine concentration without essential influence of changes in the thyroxine-binding proteins in serum.

  7. Diagnostic Evaluation of Effective Thyroxine Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Choi, Sang Jae; Ro, Heung Kyu; Lee, Hong Kyu; Koh, Chang Soon; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1975-09-15

    The purpose of the present study is to evaluate the diagnostic value of the ETR test as compared to other thyroid function tests in normal persons, patients with thyroid disorders and patients with alterations of thyroxine-binding proteins. The ETR values were obtained from 35 cases as normal control, 63 hyperthyroid patients, 56 euthyroid patients, 23 hypothyroid patients, 10 pregnant women, 5 women taking oral contraceptive medication, 8 liver cirrhosis patients and 4 nephrotic syndrome patients. The results obtained were as follows. 1) The mean value of ETR obtained from the normal controls was 0.99+-0.06. 2) The mean ETR values of various thyroid states were 1.25+-0.16 in hyperthyroidism, 0.99+-0.08 in euthyroidism and 0.82+-0.05 in hypothyroidism and significant difference was found between these groups. 3) Seven out of 63 hyperthyroid patients (11.1%) and 2 out of 23 hypothyroid patients (8.7%) had ETR values within normal range and among the 56 euthyroid patients 6 (10.7%) had ETR values outside normal range, so the diagnostic compatibility of ETR was 89.4% in thyroid diseases. 4) Even though the ETR value was well correlated with {sup 131}I-thyroid uptake rate, serum T{sub 3} resin uptake rate and serum T{sub 4}, a high positive correlation was found (r=0.79) between ETR and T{sub 7}. 5) The mean ETR values from patients with alteration in TBG binding capacity were 0.99+-0.05 in pregnant women, 0.98+-0.04 in women with oral contraceptive medication, 1.04+-0.09 in liver cirrhosis patients and 0.94+-0.02 in nephrotic syndrome patients and most of them (85.2%) had ETR values within normal range. Our results, therefore, suggests that the ETR estimation does offer the simplest and most reliable single procedure for the screening and diagnosis of various thyroid diseases as a indirect indicator of serum-free thyroxine concentration without essential influence of changes in the thyroxine-binding proteins in serum.

  8. Diagnostic Air Quality Model Evaluation of Source-Specific Primary and Secondary Fine Particulate Carbon

    Science.gov (United States)

    Ambient measurements of 78 source-specific tracers of primary and secondary carbonaceous fine particulate matter collected at four midwestern United States locations over a full year (March 2004–February 2005) provided an unprecedented opportunity to diagnostically evaluate...

  9. The development, evaluation and performance of molecular diagnostics for detection of Mycobacterium tuberculosis.

    Science.gov (United States)

    Bates, Matthew; Zumla, Alimuddin

    2016-01-01

    The unique pathogenesis of tuberculosis (TB) poses several barriers to the development of accurate diagnostics: a) the establishment of life-long latency by Mycobacterium tuberculosis (M.tb) after primary infection confounds the development of classical antibody or antigen based assays; b) our poor understanding of the molecular pathways that influence progression from latent to active disease; c) the intracellular nature of M.tb infection in tissues means that M.tb and/or its components, are not readily detectable in peripheral specimens; and d) the variable presence of M.tb bacilli in specimens from patients with extrapulmonary TB or children. The literature on the current portfolio of molecular diagnostics tests for TB is reviewed here and the developmental pipeline is summarized. Also reviewed are data from recently published operational research on the GeneXpert MTB/RIF assay and discussed are the lessons that can be taken forward for the design of studies to evaluate the impact of TB diagnostics.

  10. How to appraise a diagnostic test

    Directory of Open Access Journals (Sweden)

    Ramanitharan Manikandan

    2011-01-01

    Full Text Available Urologists frequently encounter problems in making a clinical diagnosis whose resolution requires the use of diagnostic tests. With an ever increasing choice of investigations being available, the urologist often has to decide which diagnostic test(s will best resolve the patient′s diagnostic problem. In this article, we aim to help the urologist understand how to critically appraise studies on diagnostic tests and make a rational choice. This article presents the guiding principles in scientifically assessing studies on diagnostic tests by proposing a clinical scenario. The authors describe a standardized protocol to assess the validity of the test and its relevance to the clinical problem that can help the urologist in decision making. The three important issues to be considered when evaluating the validity of the study are to identify how the study population was chosen, how the test was performed and whether there is a comparison to the gold standard test so as to confirm or refute the diagnosis. Then, the urologist would need to know the probability of the test in providing the correct diagnosis in an individual patient in order to decide about its utility in solving the diagnostic dilemma. By performing the steps described in this article, the urologist would be able to critically appraise diagnostic studies and draw meaningful conclusions about the investigations in terms of validity, results and its applicability to the patient′s problem. This would provide a scientific basis for using diagnostic tests for improving patient care.

  11. Radiation exposure in diagnostic medicine

    International Nuclear Information System (INIS)

    Haehnel, S.; Michalczak, H.; Reinoehl-Kompa, S.

    1995-01-01

    This volume includes the manuscripts of the papers read at the conference as well as a summary and assessment of its results. The scientific discussions were centred upon the following issues: - International surveys and comparisons of rdiation exposures in diagnostic radiology and nuclear medicine, frequency of the individual diagnostic procedures and age distribution of patients examined; - policies and regulations for the radiation protection of patients, charcteristic dosimetric values and practical usefulness of the effective dose concept during medical examinations; - assessments of the relative benefits and risks and measures to reduce the radiation exposure in the light of quality assurance aspects. The main objective of this conference not only was to evaluate the risks from diagnostic radiology and nuclear medicine but also to encourgage a critical analysis and adjustment of examination routines followed in everyday practice. Among the measures recommended were quality assurance, maintenace of international standards, development of guidelines, introduction of standard doses, improved training and professional education of personnel as well as surveys and analyses of certain examination procedures associated with substantial radiation exposure. (orig./MG) [de

  12. Multicenter evaluation of molecular and culture-dependent diagnostics for Shigella species and Entero-invasive Escherichia coli in the Netherlands

    NARCIS (Netherlands)

    van den Beld, Maaike J. C.; Friedrich, Alexander W.; van Zanten, Evert; Reubsaet, Frans A. G.; Kooistra-Smid, Mirjam A. M. D.; Rossen, John W. A.

    2016-01-01

    An inter-laboratory collaborative trial for the evaluation of diagnostics for detection and identification of Shigella species and Entero-invasive Escherichia coil (EIEC) was performed. Sixteen Medical Microbiological Laboratories (MMLs) participated. MMLs were interviewed about their diagnostic

  13. Does evaluation of the ligamentous compartment enhance diagnostic utility of sacroiliac joint MRI in axial spondyloarthritis?

    DEFF Research Database (Denmark)

    Weber, Ulrich; Maksymowych, Walter P; Chan, Stanley M

    2015-01-01

    in the ligamentous compartment and their potential diagnostic utility in axial SpA. We therefore aimed to evaluate the ligamentous compartment on sacroiliac joint MRI for lesion distribution and potential incremental value towards diagnosis of SpA over and above the traditional assessment of the cartilaginous...... and ligamentous compartment. The incremental value of evaluating the ligamentous additionally to the cartilaginous compartment alone for diagnosis of SpA was graded qualitatively. We determined the lesion distribution between the two compartments, and the impact of the ligamentous compartment evaluation...... on diagnostic utility. RESULTS: MRI bone marrow lesions solely in the ligamentous compartment in the absence of lesions in the cartilaginous compartment were reported in just 0-2.0/0-4.0 % (BME/fat metaplasia) of all subjects. Additional assessment of the ligamentous compartment was regarded as essential...

  14. Improving Diagnostics and Treatments for GWI Females by Accounting for the Effects of PTSD

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0552 TITLE: Improving Diagnostics and Treatments for GWI Females by Accounting for the Effects of PTSD PRINCIPAL...entered data with past data collections efforts containing additional psychological and symptom based measures including the 36 Item Short Form...differences in psychological and symptom measures were run between the low trauma control group (HC), and the three classification of GWI: total GWI

  15. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter.

    Science.gov (United States)

    Au, Frederick Wing-Fai; Ghai, Sandeep; Moshonov, Hadas; Kahn, Harriette; Brennan, Cressida; Dua, Hemi; Crystal, Pavel

    2014-09-01

    The purpose of this article is to assess the diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses and to determine the most discriminatory parameter. B-mode ultrasound and shear wave elastography were performed before core biopsy of 123 masses in 112 women. The diagnostic performance of ultrasound and quantitative shear wave elastography parameters (mean elasticity, maximum elasticity, and elasticity ratio) were compared. The added effect of shear wave elastography on the performance of ultrasound was determined. The mean elasticity, maximum elasticity, and elasticity ratio were 24.8 kPa, 30.3 kPa, and 1.90, respectively, for 79 benign masses and 130.7 kPa, 154.9 kPa, and 11.52, respectively, for 44 malignant masses (p shear wave elastography parameter was higher than that of ultrasound (p shear wave elastography parameters to the evaluation of BI-RADS category 4a masses, about 90% of masses could be downgraded to BI-RADS category 3. The numbers of downgraded masses were 40 of 44 (91%) for mean elasticity, 39 of 44 (89%) for maximum elasticity, and 42 of 44 (95%) for elasticity ratio. The numbers of correctly downgraded masses were 39 of 40 (98%) for mean elasticity, 38 of 39 (97%) for maximum elasticity, and 41 of 42 (98%) for elasticity ratio. There was improvement in the diagnostic performance of ultrasound of mass assessment with shear wave elastography parameters added to BI-RADS category 4a masses compared with ultrasound alone. Combined ultrasound and elasticity ratio had the highest improvement, from 35.44% to 87.34% for specificity, from 45.74% to 80.77% for positive predictive value, and from 57.72% to 90.24% for accuracy (p shear wave elastography parameters of benign and malignant solid breast masses. By adding shear wave elastography parameters to BI-RADS category 4a masses, we found that about 90% of them could be correctly downgraded to BI-RADS category 3, thereby avoiding biopsy. Elasticity ratio

  16. Diffuse Infiltrative Splenic Lymphoma: Diagnostic Efficacy of Arterial-Phase CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Eun; Cho, June-Sik; Shin, Kyung Sook; Kim, Song Soo; You, Sun Kyoung; Park, Jae Woo; Shin, Hye Soo; Yoon, Yeo Chang [Department of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon 35015 (Korea, Republic of)

    2016-11-01

    To evaluate the diagnostic performance of obliteration of normal heterogeneous enhancement of the spleen (ONHES) on arterial phase (AP) computed tomography (CT) images in diffuse infiltrative splenic lymphoma (DISL). One hundred and thirty-six patients with lymphoma who had undergone two-phase (arterial and portal venous) abdominal CT were included in this study. We retrospectively evaluated the diagnostic performance of ONHES on AP CT in diagnosing DISL. Two observers evaluated ONHES on AP CT using the 5-point confidence level and assessed the presence or absence of subjective splenomegaly on axial CT images. Another two observers measured the splenic index as proposed by objective CT criteria. Statistical analysis included interobserver agreement and diagnostic performance of CT findings. Eleven of the 136 patients with lymphoma had DISL. The area under the receiver operating characteristic curve of ONHES (0.948 for observer 1 and 0.922 for observer 2) was superior to that of the splenic index (0.872 for observer 3 and 0.877 for observer 4), but the difference was not statistically significant (p > 0.05). The diagnostic performance of ONHES in conjunction with subjective splenomegaly showed higher diagnostic performance, as compared with subjective splenomegaly alone (accuracy: 100% and 85.3% for observer 1, 98.5% and 87.5% for observer 2; positive predictive value: 100% and 35.5% for observer 1, 90.9% and 39.3% for observer 2, respectively). Obliteration of normal heterogeneous enhancement of the spleen in conjunction with subjective splenomegaly can improve the diagnostic performance for DISL. Our results suggest that ONHES on AP CT images could be useful as an adjunctive diagnostic indicator of DISL in patients with lymphoma.

  17. Diffuse infiltrative splenic lymphoma; Diagnostic efficacy of arterial-phase CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Eun; Cho, June Sik; Shin, Kyung Sook; Kim, Song Soo; You, Sun Kyoung; Park, Jae Woo; Shin, Hye Soo; Yoon, Yeo Chang [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2016-09-15

    To evaluate the diagnostic performance of obliteration of normal heterogeneous enhancement of the spleen (ONHES) on arterial phase (AP) computed tomography (CT) images in diffuse infiltrative splenic lymphoma (DISL). One hundred and thirty-six patients with lymphoma who had undergone two-phase (arterial and portal venous) abdominal CT were included in this study. We retrospectively evaluated the diagnostic performance of ONHES on AP CT in diagnosing DISL. Two observers evaluated ONHES on AP CT using the 5-point confidence level and assessed the presence or absence of subjective splenomegaly on axial CT images. Another two observers measured the splenic index as proposed by objective CT criteria. Statistical analysis included interobserver agreement and diagnostic performance of CT findings. Eleven of the 136 patients with lymphoma had DISL. The area under the receiver operating characteristic curve of ONHES (0.948 for observer 1 and 0.922 for observer 2) was superior to that of the splenic index (0.872 for observer 3 and 0.877 for observer 4), but the difference was not statistically significant (p > 0.05). The diagnostic performance of ONHES in conjunction with subjective splenomegaly showed higher diagnostic performance, as compared with subjective splenomegaly alone (accuracy: 100% and 85.3% for observer 1, 98.5% and 87.5% for observer 2; positive predictive value: 100% and 35.5% for observer 1, 90.9% and 39.3% for observer 2, respectively). Obliteration of normal heterogeneous enhancement of the spleen in conjunction with subjective splenomegaly can improve the diagnostic performance for DISL. Our results suggest that ONHES on AP CT images could be useful as an adjunctive diagnostic indicator of DISL in patients with lymphoma.

  18. Diffuse Infiltrative Splenic Lymphoma: Diagnostic Efficacy of Arterial-Phase CT

    International Nuclear Information System (INIS)

    Lee, Jeong Eun; Cho, June-Sik; Shin, Kyung Sook; Kim, Song Soo; You, Sun Kyoung; Park, Jae Woo; Shin, Hye Soo; Yoon, Yeo Chang

    2016-01-01

    To evaluate the diagnostic performance of obliteration of normal heterogeneous enhancement of the spleen (ONHES) on arterial phase (AP) computed tomography (CT) images in diffuse infiltrative splenic lymphoma (DISL). One hundred and thirty-six patients with lymphoma who had undergone two-phase (arterial and portal venous) abdominal CT were included in this study. We retrospectively evaluated the diagnostic performance of ONHES on AP CT in diagnosing DISL. Two observers evaluated ONHES on AP CT using the 5-point confidence level and assessed the presence or absence of subjective splenomegaly on axial CT images. Another two observers measured the splenic index as proposed by objective CT criteria. Statistical analysis included interobserver agreement and diagnostic performance of CT findings. Eleven of the 136 patients with lymphoma had DISL. The area under the receiver operating characteristic curve of ONHES (0.948 for observer 1 and 0.922 for observer 2) was superior to that of the splenic index (0.872 for observer 3 and 0.877 for observer 4), but the difference was not statistically significant (p > 0.05). The diagnostic performance of ONHES in conjunction with subjective splenomegaly showed higher diagnostic performance, as compared with subjective splenomegaly alone (accuracy: 100% and 85.3% for observer 1, 98.5% and 87.5% for observer 2; positive predictive value: 100% and 35.5% for observer 1, 90.9% and 39.3% for observer 2, respectively). Obliteration of normal heterogeneous enhancement of the spleen in conjunction with subjective splenomegaly can improve the diagnostic performance for DISL. Our results suggest that ONHES on AP CT images could be useful as an adjunctive diagnostic indicator of DISL in patients with lymphoma

  19. Evaluation of Fast Technology Analysis (FTA) Cards as an improved method for specimen collection and shipment targeting viruses associated with Bovine Respiratory Disease Complex.

    Science.gov (United States)

    Liang, Xiao; Chigerwe, Munashe; Hietala, Sharon K; Crossley, Beate M

    2014-06-01

    In order to improve the analytic quality of respiratory specimens collected from cattle for nucleic acid-based diagnosis, a study was undertaken to verify realtime PCR efficiency of specimens collected and stabilized on FTA Cards™, filter paper which is treated chemically. Nucleic acids collected using FTA Cards without the need for a cold-chain or special liquid media handling provided realtime PCR results consistent (96.8% agreement, kappa 0.923 [95% CI=0.89-0.96]) with the same specimens collected using traditional viral transport media and shipped on ice using the U.S. Department of Transportation mandated liquid handling requirements. Nucleic acid stabilization on FTA Cards was evaluated over a temperature range (-27 °C to +46 °C) for up to 14 days to mimic environmental conditions for diagnostic sample handling between collection and processing in a routine veterinary laboratory. No significant difference (P≥0.05) was observed in realtime PCR cycle threshold values over the temperature range and time storage conditions for Bovine Viral Diarrhea virus, Bovine Respiratory Syncytial virus, Bovine Coronavirus, and Bovine Herpesvirus I. The four viruses evaluated in the study are associated with Bovine Respiratory Disease Complex where improvements in ease and reliability of specimen collection and shipping would enhance the diagnostic quality of specimens collected in the field, and ultimately improve diagnostic efficiency. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Osseous Metastase of Occult Paraganglioma: A Diagnostic Medical Error

    Directory of Open Access Journals (Sweden)

    Ghasemi TA

    2013-10-01

    Full Text Available Introduction: Diagnostic errors have a natural complexity. Medical diagnoses make up a large proportion of all medical errors and cause much suffering and harm. Compared to other types of error, diagnostic errors receive little attention-a major factor in continuity of unacceptable rates of diagnostic error. Case: A 55-year-old woman presented to the emergency department (ED complaining of bone pain which has been started a month ago and increased gradually in the upper right thigh. Following the emergency evaluation she was sent home with pain medication. On the second visit, a femur neck fracture was seen in the x-ray. She underwent hemiarthroplasty and was discharged. Over several weeks she was reevaluated by many Physicians, because of her worsening pain .In the third visit after the surgery, her x-ray showed bone destruction and following bone biopsy, malignant paraganglioma was diagnosed. Discussion and solution: In all cases in which patient comes to us with skeletal pain, getting a comprehensive history and a full physical examination are prior to lab tests and x-rays. Bone metastasis which can develop severe pain and pathological fractures, is common in patients with malignant paraganglioma. Effective steps for diagnostic error prevention are: Considering the diagnostic error in the normal range of quality assurance surveillance and review, identifying the elements leading to diagnostic errors and getting feedback on the diagnoses Physicians make, in order to improve their skills. Conclusion: It is an every health system priority to identify, analyze, and prevent diagnostic errors in order to improve patient safety

  1. An economic evaluation of public programs for internationalization: the case of the Diagnostic Program in Spain.

    Science.gov (United States)

    Cansino, José M; Lopez-Melendo, Jaime; Pablo-Romero, María del P; Sánchez-Braza, Antonio

    2013-12-01

    This paper evaluates the Diagnostic Program in Spain which is a publicly funded program to promote internationalization of companies located in Andalusia (south of Spain). The methodology used is the propensity score-matching. The treatment group consists of companies which participated in the Program until 2008. The control group has companies which planned to participate in the Program but had not done so up to that date. The response variable measures the ratio of export to total sales for each company. Four covariates have been taken into account: activity, location, sales and number of employees. The analysis leads to the conclusion that the companies that participated in the Program improved their ratio of exports to total sales by about 10 percentage points. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Evaluation of reduced-dose CT for acute non-traumatic abdominal pain: evaluation of diagnostic accuracy in comparison to standard-dose CT.

    Science.gov (United States)

    Othman, Ahmed E; Bongers, Malte Niklas; Zinsser, Dominik; Schabel, Christoph; Wichmann, Julian L; Arshid, Rami; Notohamiprodjo, Mike; Nikolaou, Konstantin; Bamberg, Fabian

    2018-01-01

    Background Patients with acute non-traumatic abdominal pain often undergo abdominal computed tomography (CT). However, abdominal CT is associated with high radiation exposure. Purpose To evaluate diagnostic performance of a reduced-dose 100 kVp CT protocol with advanced modeled iterative reconstruction as compared to a linearly blended 120 kVp protocol for assessment of acute, non-traumatic abdominal pain. Material and Methods Two radiologists assessed 100 kVp and linearly blended 120 kVp series of 112 consecutive patients with acute non-traumatic pain (onset diagnostic confidence. Both 100 kVp and linearly blended 120 kVp series were quantitatively evaluated regarding radiation dose and image noise. Comparative statistics and diagnostic accuracy was calculated using receiver operating curve (ROC) statistics, with final clinical diagnosis/clinical follow-up as reference standard. Results Image quality was high for both series without detectable significant differences ( P = 0.157). Image noise and artifacts were rated low for both series but significantly higher for 100 kVp ( P ≤ 0.021). Diagnostic accuracy was high for both series (120 kVp: area under the curve [AUC] = 0.950, sensitivity = 0.958, specificity = 0.941; 100 kVp: AUC ≥ 0.910, sensitivity ≥ 0.937, specificity = 0.882; P ≥ 0.516) with almost perfect inter-rater agreement (Kappa = 0.939). Diagnostic confidence was high for both dose levels without significant differences (100 kVp 5, range 4-5; 120 kVp 5, range 3-5; P = 0.134). The 100 kVp series yielded 26.1% lower radiation dose compared with the 120 kVp series (5.72 ± 2.23 mSv versus 7.75 ± 3.02 mSv, P diagnostic accuracy for the assessment of acute non-traumatic abdominal pain.

  3. A new generation of optical diagnostics for bladder cancer: technology, diagnostic accuracy, and future applications

    NARCIS (Netherlands)

    Cauberg, Evelyne C. C.; de Bruin, Daniël M.; Faber, Dirk J.; van Leeuwen, Ton G.; de La Rosette, Jean J. M. C. H.; de Reijke, Theo M.

    2009-01-01

    CONTEXT: New developments in optical diagnostics have a potential for less invasive and improved detection of bladder cancer. OBJECTIVE: To provide an overview of the technology and diagnostic yield of recently developed optical diagnostics for bladder cancer and to outline their potential future

  4. Novette diagnostic support. Final report

    International Nuclear Information System (INIS)

    Cirigliano, R.; Franco, E.; Koppel, L.; Rodrigues, B.; Smith, J.

    1985-02-01

    The primary research areas were the following: (1) contribute x-ray diagnostic, experimental, and data reduction and analysis support for the Novette DANTE x-ray spectrometer experiments. This effort was expanded to improve the overall quality of the Novette database; (2) experimental and calculational characterization of the x-ray imaging properties of an ellipsoidal x-ray collection optic serving as a sensitivity enhancing component of the Transmission Grating Streak Spectrometer; (3) performance simulation of the x-ray dispersion properties of candidate x-ray laser cavity, normal incidence end-mirror optics; (4) contribute x-ray diagnostic, experimental, and data reduction and analysis support for the Novette Henway crystal spectrometer and the MCPIGS microchannel plate intensified grazing incident spectrometer experiments; and (5) perform a technical performance vs cost evaluation of commercially available hardware required to perform the NOVA neutron time-of-flight experiments

  5. Picosecond image-converter diagnostics

    International Nuclear Information System (INIS)

    Schelev, M.Ya.

    1975-01-01

    A brief review is presented of the improvements in picosecond image-converter diagnostics carried out since the previous Congress in 1972. The account is given under the following headings: picosecond image converter cameras for visible and x-ray radiation diagnostics; Nd:glass and ruby mode-locked laser measurements; x-ray plasma emission diagnostics; computer treatment of pictures produced by picosecond cameras. (U.K.)

  6. Climate Model Diagnostic Analyzer Web Service System

    Science.gov (United States)

    Lee, S.; Pan, L.; Zhai, C.; Tang, B.; Kubar, T. L.; Li, J.; Zhang, J.; Wang, W.

    2015-12-01

    Both the National Research Council Decadal Survey and the latest Intergovernmental Panel on Climate Change Assessment Report stressed the need for the comprehensive and innovative evaluation of climate models with the synergistic use of global satellite observations in order to improve our weather and climate simulation and prediction capabilities. The abundance of satellite observations for fundamental climate parameters and the availability of coordinated model outputs from CMIP5 for the same parameters offer a great opportunity to understand and diagnose model biases in climate models. In addition, the Obs4MIPs efforts have created several key global observational datasets that are readily usable for model evaluations. However, a model diagnostic evaluation process requires physics-based multi-variable comparisons that typically involve large-volume and heterogeneous datasets, making them both computationally- and data-intensive. In response, we have developed a novel methodology to diagnose model biases in contemporary climate models and implementing the methodology as a web-service based, cloud-enabled, provenance-supported climate-model evaluation system. The evaluation system is named Climate Model Diagnostic Analyzer (CMDA), which is the product of the research and technology development investments of several current and past NASA ROSES programs. The current technologies and infrastructure of CMDA are designed and selected to address several technical challenges that the Earth science modeling and model analysis community faces in evaluating and diagnosing climate models. In particular, we have three key technology components: (1) diagnostic analysis methodology; (2) web-service based, cloud-enabled technology; (3) provenance-supported technology. The diagnostic analysis methodology includes random forest feature importance ranking, conditional probability distribution function, conditional sampling, and time-lagged correlation map. We have implemented the

  7. Diagnostic classification past, present, and future: implications for pharmacotherapy.

    Science.gov (United States)

    Howland, Robert H

    2013-04-01

    Making a diagnosis is a key step in understanding the natural course of a disorder, selecting an appropriate treatment for the disorder, and predicting its response to treatment. Diagnostic proposals can be evaluated in two ways: reliability and validity. The reliability and validity of diagnoses are not one and the same, although establishing reliability is usually a necessary step before being able to evaluate and determine validity. There is little evidence that most psychiatric diagnoses are valid, but the reliability of diagnoses using classification systems developed since 1970 have greatly improved and are important for clinical practice and research. Past and current diagnostic systems have not optimally assisted the search for disorder-specific pathophysiological mechanisms, and they do not provide the specificity that clinicians would like when selecting medication. The Research Domain Criteria project is intended to shift research away from categorical diagnoses to focus on dysregulated neurobiological systems, and this approach ultimately may be more useful for understanding the pathophysiology of mental disorders and improving the development and use of treatment interventions. Copyright 2013, SLACK Incorporated.

  8. Diagnostic performance and color overlay pattern in shear wave elastography (SWE) for palpable breast mass.

    Science.gov (United States)

    Park, Jiyoon; Woo, Ok Hee; Shin, Hye Seon; Cho, Kyu Ran; Seo, Bo Kyoung; Kang, Eun Young

    2015-10-01

    The purpose of this study is to evaluate the diagnostic performance of SWE in palpable breast mass and to compare with color overlay pattern in SWE with conventional US and quantitative SWE for assessing palpable breast mass. SWE and conventional breast US were performed in 133 women with 156 palpable breast lesions (81 benign, 75 malignant) between August 2013 to June 2014. Either pathology or periodic imaging surveillance more than 2 years was a reference standard. Existence of previous image was blinded to performing radiologists. US BI-RADS final assessment, qualitative and quantitative SWE measurements were evaluated. Diagnostic performances of grayscale US, SWE and US combined to SWE were calculated and compared. Correlation between pattern classification and quantitative SWE was evaluated. Both color overlay pattern and quantitative SWE improved the specificity of conventional US, from 81.48% to 96.30% (p=0.0005), without improvement in sensitivity. Color overlay pattern was significantly related to all quantitative SWE parameters and malignancy rate (pbreast mass, conventional US combine to SWE improves specificity and reduces the number of biopsies that ultimately yield a benign result. Color overlay pattern classification is more quick and easy and may represent quantitative SWE measurements with similar diagnostic performances. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Diagnostic evaluation of dementia in the secondary health care sector

    DEFF Research Database (Denmark)

    Phung, Thien Kieu Thi; Andersen, Birgitte Bo; Kessing, Lars Vedel

    2009-01-01

    BACKGROUND: We conducted a nationwide registry-based study of the quality of diagnostic evaluation for dementia in the secondary health care sector. METHOD: Two hundred patients were randomly selected from the patient population (4,682 patients) registered for the first time with a dementia...... diagnosis in the nationwide hospital registries during the last 6 months of 2003. Through medical record review, we evaluated the completeness of the work-up on which the dementia diagnosis was based, using evidence-based dementia guidelines as reference standards. RESULTS: Satisfactory or acceptable...... completion of the basic dementia work-up was documented in 51.3% of the patients. Only 11.5% of those with unsatisfactory work-up were referred to follow-up investigations. Dementia syndrome was confirmed in 88.5% of the cases, but correct subtypes were diagnosed in only 35.1%. CONCLUSION: The adherence...

  10. Role of diagnostic hystero-laparoscopy in the evaluation of infertility: A retrospective study of 300 patients

    Directory of Open Access Journals (Sweden)

    Prasanta K Nayak

    2013-01-01

    Full Text Available Objective: To determine the role of diagnostic hysterolaparoscopy in the evaluation of infertility in tertiary care centres. Materials and Methods: This retrospective study was conducted at two tertiary care centres (the infertility clinics of Sriram Chandra Bhanj Medical College and Prachi hospital at Cuttack, Odisha throughout the year in 2008. Women aged 20-40 years with normal hormone profile without male factor infertility were included. Results: Out of 300 cases, 206 (69% patients had primary infertility. While laparoscopy detected abnormalities in 34% of the cases, significant hysteroscopy findings were noted in 18% of cases. Together, diagnostic hysterolaparoscopy detected abnormalities in 26% of the infertile patients in both groups. While the most common laparoscopic abnormality was endometriosis (14% and adnexal adhesion (12% in primary and secondary infertile patients, respectively, hysteroscopy found intrauterine septum as the most common abnormality in both groups. Conclusions: Hysterolaparoscopy is an effective diagnostic tool for evaluation of certain significant and correctable tubo-peritoneal and intrauterine pathologies like peritoneal endometriosis, adnexal adhesions, and subseptate uterus, which are usually missed by other imaging modalities.

  11. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    Science.gov (United States)

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (pultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  12. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  13. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis

    International Nuclear Information System (INIS)

    Li, S.; Tang, X.; Peng, L.; Luo, Y.; Dong, R.; Liu, J.

    2015-01-01

    Aim: To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFR CT ) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. Materials and methods: A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFR CT , with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Results: Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR−), and diagnostic odds ratio (DOR) for FFR CT were 89% (85–93%), 71% (65–75%), 70% (65–75%), 90% (85–93%), 3.31 (1.79–6.14), 0.16 (0.11–0.23), and 21.21 (9.15–49.15) at the patient-level, and 83% (78–63%), 78% (75–81%), 61% (56–65%), 92% (89–90%), 4.02 (1.84–8.80), 0.22 (0.13–0.35), and 19.15 (5.73–63.93) at the vessel-level. At per-patient analysis, FFR CT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR−, and DOR versus those of CTA. At per-vessel analysis, FFR CT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR−, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFR CT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. Conclusions: FFR CT , which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions

  14. Collaboration between radiological technologists (radiographers) and junior doctors during image interpretation improves the accuracy of diagnostic decisions

    International Nuclear Information System (INIS)

    Kelly, B.S.; Rainford, L.A.; Gray, J.; McEntee, M.F.

    2012-01-01

    Rationale and Objectives: In Emergency Departments (ED) junior doctors regularly make diagnostic decisions based on radiographic images. This study investigates whether collaboration between junior doctors and radiographers impacts on diagnostic accuracy. Materials and Methods: Research was carried out in the ED of a university teaching hospital and included 10 pairs of participants. Radiographers and junior doctors were shown 42 wrist radiographs and 40 CT Brains and were asked for their level of confidence of the presence or absence of distal radius fractures or fresh intracranial bleeds respectively using ViewDEX software, first working alone and then in pairs. Receiver Operating Characteristic was used to analyze performance. Results were compared using one-way analysis of variance. Results: The results showed statistically significant improvements in the Area Under the Curve (AUC) of the junior doctors when working with the radiographers for both sets of images (wrist and CT) treated as random readers and cases (p ≤ 0.008 and p ≤ 0.0026 respectively). While the radiographers’ results saw no significant changes, their mean Az values did show an increasing trend when working in collaboration. Conclusion: Improvement in performance of junior doctors following collaboration strongly suggests changes in the potential to improve accuracy of patient diagnosis and therefore patient care. Further training for junior doctors in the interpretation of diagnostic images should also be considered. Decision making of junior doctors was positively impacted on after introducing the opinion of a radiographer. Collaboration exceeds the sum of the parts; the two professions are better together.

  15. Genetic test utilization and diagnostic yield in adult patients with neurological disorders.

    Science.gov (United States)

    Bardakjian, Tanya M; Helbig, Ingo; Quinn, Colin; Elman, Lauren B; McCluskey, Leo F; Scherer, Steven S; Gonzalez-Alegre, Pedro

    2018-03-28

    To determine the diagnostic yield of different genetic test modalities in adult patients with neurological disorders, we evaluated all adult patients seen for genetic diagnostic evaluation in the outpatient neurology practice at the University of Pennsylvania between January 2016 and April 2017 as part of the newly created Penn Neurogenetics Program. Subjects were identified through our electronic medical system as those evaluated by the Program's single clinical genetic counselor in that period. A total of 377 patients were evaluated by the Penn Neurogenetics Program in different settings and genetic testing recommended. Of those, 182 (48%) were seen in subspecialty clinic setting and 195 (52%) in a General Neurogenetics Clinic. Genetic testing was completed in over 80% of patients in whom it was recommended. The diagnostic yield was 32% across disease groups. Stratified by testing modality, the yield was highest with directed testing (50%) and array comparative genomic hybridization (45%), followed by gene panels and exome testing (25% each). In conclusion, genetic testing can be successfully requested in clinic in a large majority of adult patients. Age is not a limiting factor for a genetic diagnostic evaluation and the yield of clinical testing across phenotypes (almost 30%) is consistent with previous phenotype-focused or research-based studies. These results should inform the development of specific guidelines for clinical testing and serve as evidence to improve reimbursement by insurance payers.

  16. Structured approach to design of diagnostic test evaluation studies for chronic progressive infections in animals

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils; Gardner, Ian Andrew

    2011-01-01

    Diagnostic test evaluations (DTEs) for chronic infections are challenging because a protracted incubation period has to be considered in the design of the DTE, and the adverse effects of infection may be widespread and progressive over an animal's entire life. Frequently, the specific purpose......) than originally intended. The objective of this paper is to outline a structured approach to the design and conduct of a DTE for diagnostic tests used for chronic infections in animals, and intended for different purposes. We describe the process from reflections about test purpose and the underlying...... of the test is not formally considered when a test is evaluated. Therefore, the result is often a DTE where test sensitivity and specificity estimates are biased, either because of problems with establishing the true infection status or because the test detects another aspect of the infection (and analyte...

  17. Efficient diagnostic evaluation of fractures of the talus - an analysis based on examination of 40 patients

    International Nuclear Information System (INIS)

    Foerster, A.; Roehnert, W.; Koehler, K.

    1997-01-01

    Conventional radiography imaging the ankle joint in two planes is the initial technique applied, giving information on further diagnostic evaluation required. CT is of importance for such additional examination, and spiral CT in particular, as it can generate directly comparable pictures due to its standardised examination techniques. Joint surfaces are visualized without superpositions. Fractures and their numbers, dislocations as well as involvement of joint surfaces can be better detected. Also, spiral CT, due to the continuous data set generated, permits 2D reconstructions of high quality. 3D Reconstructions as a rule do not supply additional information. CT can be applied for diagnostic evaluation of the tendon and ligamentum system/soft tissue, but MRI will yield better results. (orig./CB) [de

  18. Can continuous scans in orthogonal planes improve diagnostic performance of shear wave elastography for breast lesions?

    Science.gov (United States)

    Yang, Pan; Peng, Yulan; Zhao, Haina; Luo, Honghao; Jin, Ya; He, Yushuang

    2015-01-01

    Static shear wave elastography (SWE) is used to detect breast lesions, but slice and plane selections result in discrepancies. To evaluate the intraobserver reproducibility of continuous SWE, and whether quantitative elasticities in orthogonal planes perform better in the differential diagnosis of breast lesions. One hundred and twenty-two breast lesions scheduled for ultrasound-guided biopsy were recruited. Continuous SWE scans were conducted in orthogonal planes separately. Quantitative elasticities and histopathology results were collected. Reproducibility in the same plane and diagnostic performance in different planes were evaluated. The maximum and mean elasticities of the hardest portion, and standard deviation of whole lesion, had high inter-class correlation coefficients (0.87 to 0.95) and large areas under receiver operation characteristic curve (0.887 to 0.899). Without loss of accuracy, sensitivities had increased in orthogonal planes compared with single plane (from 73.17% up to 82.93% at most). Mean elasticity of whole lesion and lesion-to-parenchyma ratio were significantly less reproducible and less accurate. Continuous SWE is highly reproducible for the same observer. The maximum and mean elasticities of the hardest portion and standard deviation of whole lesion are most reliable. Furthermore, the sensitivities of the three parameters are improved in orthogonal planes without loss of accuracies.

  19. Evaluating Utility in Diagnostic Decision Making.

    Science.gov (United States)

    Harber, Jean R.

    1981-01-01

    The utility of the procedures special educators apply in making decisions about the identification of handicapped individuals has not been thoroughly studied. The paper examines the utility of diagnostic decision making from the perspective of receiver operating curve analysis. (Author)

  20. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    Science.gov (United States)

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics. Copyright © 2017 American Society for Microbiology.

  1. The diagnostic adaptive behavior scale: evaluating its diagnostic sensitivity and specificity.

    Science.gov (United States)

    Balboni, Giulia; Tassé, Marc J; Schalock, Robert L; Borthwick-Duffy, Sharon A; Spreat, Scott; Thissen, David; Widaman, Keith F; Zhang, Dalun; Navas, Patricia

    2014-11-01

    The Diagnostic Adaptive Behavior Scale (DABS) was constructed with items across three domains--conceptual, social, and practical adaptive skills--and normed on a representative sample of American individuals from 4 to 21 years of age. The DABS was developed to focus its assessment around the decision point for determining the presence or absence of significant limitations of adaptive behavior for the diagnosis of Intellectual Disability (ID). The purpose of this study, which was composed of 125 individuals with and 933 without an ID-related diagnosis, was to determine the ability of the DABS to correctly identify the individuals with and without ID (i.e., sensitivity and specificity). The results indicate that the DABS sensitivity coefficients ranged from 81% to 98%, specificity coefficients ranged from 89% to 91%, and that the Area Under the Receiver Operating Characteristic Curve were excellent or good. These results indicate that the DABS has very good levels of diagnostic efficiency. Copyright © 2014. Published by Elsevier Ltd.

  2. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  3. Diagnostic errors in pediatric radiology

    International Nuclear Information System (INIS)

    Taylor, George A.; Voss, Stephan D.; Melvin, Patrice R.; Graham, Dionne A.

    2011-01-01

    Little information is known about the frequency, types and causes of diagnostic errors in imaging children. Our goals were to describe the patterns and potential etiologies of diagnostic error in our subspecialty. We reviewed 265 cases with clinically significant diagnostic errors identified during a 10-year period. Errors were defined as a diagnosis that was delayed, wrong or missed; they were classified as perceptual, cognitive, system-related or unavoidable; and they were evaluated by imaging modality and level of training of the physician involved. We identified 484 specific errors in the 265 cases reviewed (mean:1.8 errors/case). Most discrepancies involved staff (45.5%). Two hundred fifty-eight individual cognitive errors were identified in 151 cases (mean = 1.7 errors/case). Of these, 83 cases (55%) had additional perceptual or system-related errors. One hundred sixty-five perceptual errors were identified in 165 cases. Of these, 68 cases (41%) also had cognitive or system-related errors. Fifty-four system-related errors were identified in 46 cases (mean = 1.2 errors/case) of which all were multi-factorial. Seven cases were unavoidable. Our study defines a taxonomy of diagnostic errors in a large academic pediatric radiology practice and suggests that most are multi-factorial in etiology. Further study is needed to define effective strategies for improvement. (orig.)

  4. Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels (Conference Presentation)

    Science.gov (United States)

    Zhao, Jianhua; Zeng, Haishan; Kalia, Sunil; Lui, Harvey

    2017-02-01

    Background: Raman spectroscopy is a non-invasive optical technique which can measure molecular vibrational modes within tissue. A large-scale clinical study (n = 518) has demonstrated that real-time Raman spectroscopy could distinguish malignant from benign skin lesions with good diagnostic accuracy; this was validated by a follow-up independent study (n = 127). Objective: Most of the previous diagnostic algorithms have typically been based on analyzing the full band of the Raman spectra, either in the fingerprint or high wavenumber regions. Our objective in this presentation is to explore wavenumber selection based analysis in Raman spectroscopy for skin cancer diagnosis. Methods: A wavenumber selection algorithm was implemented using variably-sized wavenumber windows, which were determined by the correlation coefficient between wavenumbers. Wavenumber windows were chosen based on accumulated frequency from leave-one-out cross-validated stepwise regression or least and shrinkage selection operator (LASSO). The diagnostic algorithms were then generated from the selected wavenumber windows using multivariate statistical analyses, including principal component and general discriminant analysis (PC-GDA) and partial least squares (PLS). A total cohort of 645 confirmed lesions from 573 patients encompassing skin cancers, precancers and benign skin lesions were included. Lesion measurements were divided into training cohort (n = 518) and testing cohort (n = 127) according to the measurement time. Result: The area under the receiver operating characteristic curve (ROC) improved from 0.861-0.891 to 0.891-0.911 and the diagnostic specificity for sensitivity levels of 0.99-0.90 increased respectively from 0.17-0.65 to 0.20-0.75 by selecting specific wavenumber windows for analysis. Conclusion: Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels.

  5. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography.

    Science.gov (United States)

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-07-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio benign and malignant nodules in 2, 3 and 4 points were statistically significant (Pbenign and malignant thyroid nodules.

  6. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  7. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  8. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis.

    Science.gov (United States)

    Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J

    2015-05-01

    To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. International quality assurance project in colorectal cancer-unifying diagnostic and histopathological evaluation.

    Science.gov (United States)

    Jannasch, O; Udelnow, A; Romano, G; Dziki, A; Pavalkis, D; Lippert, H; Mroczkowski, P

    2014-04-01

    Several European countries are undertaking quality control projects in colorectal cancer. These efforts have led to improvements in survival, but a comparison between different projects reveals questionable results. The aim of this study is the presentation of results from hospitals in three different European countries participating in the International Quality Assurance in Colorectal Cancer (IQACC) project. For this publication, patients with cancer of the colon or rectum treated in 2009 and 2010 and recorded in the IQACC (Germany, Poland and Italy) were analysed. The comparison included number of patients, age, preoperative diagnostics (CT of the abdomen and thorax, MRI, colonoscopy, ultrasound, tumour markers), surgical approach, metastasis, height of rectal cancer and histopathological examination of a specimen (T stage, N stage and MERCURY classification for rectum resection). For short-term outcomes, general complications, wound dehiscence, tumour-free status at discharge, anastomotic leakage and in-hospital mortality were analysed. A total of 12,691 patients (6,756 with colon cancer, 5,935 with rectal cancer) were included in the analysis. Preoperative diagnostics differed significantly between countries. For pT and pN stages, several quality differences could be demonstrated, including missing stages (colon cancer: pT 5.7-12.5 %, pN 2.5-11.0 %; rectal cancer: pT 1.1-5.6 %, pN 1.1-15.5 %). The most relevant differences for short-term outcomes in colon cancer were found in general complications (4.2-22.8 %) and tumour-free status at discharge (74.5-91.7 %). In-hospital deaths ranged between 2.5 and 4.3 % and did not show significant differences. For rectal cancer, the country with the highest percentage of tumours localised less than 4 cm from the anal verge (16.0 %) showed the lowest frequency of amputation (8.5 %). Outcome differences were found for general complications (3.2-18.8 %), anastomotic leakage (0-4.3 %) and tumour-free status at discharge (72

  10. Recommendations for CSF AD biomarkers in the diagnostic evaluation of dementia

    DEFF Research Database (Denmark)

    Simonsen, Anja Hviid; Herukka, Sanna-Kaisa; Andreasen, Niels

    2017-01-01

    . The recommendations were developed by a multidisciplinary working group based on the available evidence and consensus from focused discussions for (i) identification of Alzheimer's disease (AD) as the cause of dementia, (ii) prediction of rate of decline, (iii) cost-effectiveness, and (iv) interpretation of results......This article presents recommendations, based on the Grading of Recommendations, Assessment, Development, and Evaluation method, for the clinical application of cerebrospinal fluid (CSF) amyloid-β1-42, tau, and phosphorylated tau in the diagnostic evaluation of patients with dementia....... The working group found sufficient evidence to support a recommendation to use CSF AD biomarkers as a supplement to clinical evaluation, particularly in uncertain and atypical cases, to identify or exclude AD as the cause of dementia. Because of insufficient evidence, it was uncertain whether CSF AD...

  11. Adulticidal Susceptibility Evaluation of Aedes albopictus Using New Diagnostic Doses in Penang Island, Malaysia.

    Science.gov (United States)

    Rahim, Junaid; Ahmad, Abu H; Ahmad, Hamdan; Ishak, Intan H; Rus, Adanan Che; Maimusa, Hamisu A

    2017-09-01

    Insecticide-based vector control approaches are facing challenges due to the development of resistance in vector mosquitoes. Therefore, a proper resistance surveillance program using baseline lethal concentrations is crucial for resistance management strategies. Currently, the World Health Organization's (WHO) diagnostic doses established for Aedes aegypti and Anopheles species are being used to study the resistance status of Aedes albopictus. In this study, we established the diagnostic doses for permethrin, deltamethrin, and malathion using a known susceptible reference strain. Five field-collected populations were screened against these doses, following the WHO protocol. This study established the diagnostic dose of malathion at 2.4%, permethrin at 0.95%, and deltamethrin at 0.28%, which differ from the WHO doses for Aedes aegypti and Anopheles spp. Among the insecticides tested on the 5 wild populations, only deltamethrin showed high effectiveness. Different susceptibility and resistance patterns were observed with permethrin, malathion, and dichloro-diphenyl-trichloroethane (DDT) at 4%. This study may assist the health authorities to improve future chemical-based vector control operations in dengue-endemic areas.

  12. Diagnostic delays in children with early-onset epilepsy: impact, reasons, and opportunities to improve care

    Science.gov (United States)

    Berg, Anne T.; Loddenkemper, Tobias; Baca, Christine B.

    2014-01-01

    in childhood. Several factors influence diagnostic delays and may represent opportunities for intervention and improved care. PMID:24313635

  13. A methodology for the quantitative evaluation of NPP fault diagnostic systems' dynamic aspects

    International Nuclear Information System (INIS)

    Kim, J.H.; Seong, P.H.

    2000-01-01

    A fault diagnostic system (FDS) is an operator decision support system which is implemented both to increase NPP efficiency as well as to reduce human error and cognitive workload that may cause nuclear power plant (NPP) accidents. Evaluation is an indispensable activity in constructing a reliable FDS. We first define the dynamic aspects of fault diagnostic systems (FDSs) for evaluation in this work. The dynamic aspect is concerned with the way a FDS responds to input. Next, we present a hierarchical structure in the evaluation for the dynamic aspects of FDSs. Dynamic aspects include both what a FDS provides and how a FDS operates. We define the former as content and the latter as behavior. Content and behavior contain two elements and six elements in the lower hierarchies, respectively. Content is a criterion for evaluating the integrity of a FDS, the problem types which a FDS deals with, along with the level of information. Behavior contains robustness, understandability, timeliness, transparency, effectiveness, and communicativeness of FDSs. On the other hand, the static aspects are concerned with the hardware and the software of the system. For quantitative evaluation, the method used to gain and aggregate the priorities of the criteria in this work is the analytic hierarchy process (AHP). The criteria at the lowest level are quantified through simple numerical expressions and questionnaires developed in this work. these well describe the characteristics of the criteria and appropriately use subjective, empirical, and technical methods. Finally, in order to demonstrate the feasibility of our evaluation method, we have performed one case study for the fault diagnosis module of OASYS TM (On-Line Operator Aid SYStem for Nuclear Power Plant), which is an operator support system developed at the Korea Advanced Institute of Science and Technology (KAIST)

  14. Implications of Continuous Quality Improvement for Program Evaluation and Evaluators.

    Science.gov (United States)

    Mark, Melvin M.; Pines, Edward

    1995-01-01

    Explores the implications that continuous quality improvement (CQI) programs are likely to have for evaluation. CQI, often known as total quality management, offers a structured approach to the analysis of an organization's processes and improvement that should provide advantages to evaluators once they have gained experience with the approach.…

  15. Diagnostic imaging of shoulder impingement

    International Nuclear Information System (INIS)

    Merl, T.; Weinhardt, H.; Oettl, G.; Lenz, M.; Riel, K.A.

    1996-01-01

    Magnetic resonance imaging is a method that has been advancing in the last few years to the modality of choice for diagnostic evaluation of the bone joints, as the method is capable of imaging not only the ossous but also the soft tissue components of the joint. MRI likewise has become an accepted method for diagnostic evaluation of syndromes of the shoulder, with high diagnostic accuracy in detecting rotator cuff lesions, or as an efficient MRI arthrography for evaluation of the instability or lesions of the labrocapsular complex. In the evaluation of early stages of shoulder impingement, the conventional MRI technique as a static technique yields indirect signs which in many cases do not provide the diagnostic certainty required in order to do justice to the functional nature of the syndrome. In these cases, functional MRI for imaging of the arm in abducted position and in rotational movement may offer a chance to early detect impingement and thus identify patients who will profit from treatment at an early stage [de

  16. Evaluation of techniques for inspection and diagnostics of HWR pressure tubes

    International Nuclear Information System (INIS)

    Choi, Jong-Ho

    2008-01-01

    Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes for Heavy Water Reactors (HWRs), are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. The objective of the CRP was to inter-compare inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of the CRP, participants investigated the capability of different techniques to detect and characterize flaws. During the second phase, participants collaborated to determine the hydrogen concentration and to detect and characterize hydride blisters in zirconium alloy pressure tubes. Eight organizations from six countries, which operate HWRs, have participated in this CRP, Most of the techniques examined are well established and many of them are regularly used during in-service inspection of pressure tubes. The inter-comparison of these techniques provides a platform for identifying a particular technique (or a set of techniques), which is more accurate and reliable as compared to others for a specified task. The CRP also witnessed some new methodologies, which can be implemented on in-service inspection tools. These new techniques could complement the existing ones to overcome their limitations, thereby improving the reliability and accuracy of in-service inspection. This CRP also identified future areas of research and development. (author)

  17. Establishing a malaria diagnostics centre of excellence in Kisumu, Kenya

    Directory of Open Access Journals (Sweden)

    McEvoy Peter

    2007-06-01

    Full Text Available Abstract Background Malaria microscopy, while the gold standard for malaria diagnosis, has limitations. Efficacy estimates in drug and vaccine malaria trials are very sensitive to small errors in microscopy endpoints. This fact led to the establishment of a Malaria Diagnostics Centre of Excellence in Kisumu, Kenya. The primary objective was to ensure valid clinical trial and diagnostic test evaluations. Key secondary objectives were technology transfer to host countries, establishment of partnerships, and training of clinical microscopists. Case description A twelve-day "long" and a four-day "short" training course consisting of supervised laboratory practicals, lectures, group discussions, demonstrations, and take home assignments were developed. Well characterized slides were developed and training materials iteratively improved. Objective pre- and post-course evaluations consisted of 30 slides (19 negative, 11 positive with a density range of 50–660 parasites/μl, a written examination (65 questions, a photographic image examination (30 images of artifacts and species specific characteristics, and a parasite counting examination. Discussion and Evaluation To date, 209 microscopists have participated from 11 countries. Seventy-seven experienced microscopists participated in the "long" courses, including 47 research microscopists. Sensitivity improved by a mean of 14% (CI 9–19% from 77% baseline (CI 73–81 %, while specificity improved by a mean of 17% (CI 11–23% from 76% (CI 70–82% baseline. Twenty-three microscopists who had been selected for a four-day refresher course showed continued improvement with a mean final sensitivity of 95% (CI 91–98% and specificity of 97% (CI 95–100%. Only 9% of those taking the pre-test in the "long" course achieved a 90% sensitivity and 95% specificity, which increased to 61% of those completing the "short" course. All measures of performance improved substantially across each of the five

  18. [THE VIRTUAL CYTOLOGIC SLIDES FOR EXTERNAL EVALUATION OF QUALITY OF IMPLEMENTATION OF CYTOLOGIC ANALYSES IN CLINICAL DIAGNOSTIC LABORATORIES: POSSIBILITIES AND PERSPECTIVES].

    Science.gov (United States)

    Djangirova, T V; Shabalova, I P; Pronichev, A N; Polyakov, E V

    2015-08-01

    The article considers application of technology of analysis of cytological slides in external quality control of clinical diagnostic laboratories. The advantages of virtual slides are demonstrated against other applied technologies of external evaluation of quality i.e. slide plate and digital micro-photography. The conditions of formation of virtual slides for external evaluation of quality of clinical diagnostic laboratories. The technology of their application is described. The success of practical application of considered technology in the Federal system of external evaluation of quality is emphasized.

  19. The diagnostic and therapeutic impact of MRI: an observational multi-centre study

    International Nuclear Information System (INIS)

    Hollingworth, William; Todd, Christopher J.; Bell, Matthew I.; Arafat, Qais; Girling, Simon; Karia, Kanti R.; Dixon, Adrian K.

    2000-01-01

    AIM: To provide information about the diagnostic and therapeutic impact of magnetic resonance imaging (MRI) and to compare the findings across diagnostic groups. MATERIALS AND METHODS: A prospective, observational study of 2017 consecutive referrals for MRI of the head, spine or knee at four imaging centres. Clinicians completed questionnaires before MRI stating initial diagnoses, diagnostic confidence and treatment plans. After imaging, a second questionnaire evaluated clinicians' revised diagnosis and treatment plans in the light of imaging findings. Patients were grouped into nine diagnostic categories for analysis. Comparison between pre- and post-imaging was used to assess the diagnostic and therapeutic impact of MRI. RESULTS: In seven of nine diagnostic groups MRI findings were associated with a diagnostic impact. Diagnoses were revised or discarded following normal MR findings and diagnostic confidence was increased by confirmative MR findings. There was no statistically significant diagnostic impact for suspected pituitary or cerebello-pontine angle lesions. In five of nine diagnostic groups (knee meniscus, knee ligament, multiple sclerosis, lumbar and cervical spine) MRI findings had a clear impact on treatment plans. CONCLUSION: This study demonstrates that in most diagnostic categories, MRI influences diagnosis and treatment. However, experimental studies are needed to prove that these diagnostic and therapeutic impacts lead to improved health. Hollingworth (2000)

  20. The diagnostic and therapeutic impact of MRI: an observational multi-centre study

    Energy Technology Data Exchange (ETDEWEB)

    Hollingworth, William; Todd, Christopher J.; Bell, Matthew I.; Arafat, Qais; Girling, Simon; Karia, Kanti R.; Dixon, Adrian K

    2000-11-01

    AIM: To provide information about the diagnostic and therapeutic impact of magnetic resonance imaging (MRI) and to compare the findings across diagnostic groups. MATERIALS AND METHODS: A prospective, observational study of 2017 consecutive referrals for MRI of the head, spine or knee at four imaging centres. Clinicians completed questionnaires before MRI stating initial diagnoses, diagnostic confidence and treatment plans. After imaging, a second questionnaire evaluated clinicians' revised diagnosis and treatment plans in the light of imaging findings. Patients were grouped into nine diagnostic categories for analysis. Comparison between pre- and post-imaging was used to assess the diagnostic and therapeutic impact of MRI. RESULTS: In seven of nine diagnostic groups MRI findings were associated with a diagnostic impact. Diagnoses were revised or discarded following normal MR findings and diagnostic confidence was increased by confirmative MR findings. There was no statistically significant diagnostic impact for suspected pituitary or cerebello-pontine angle lesions. In five of nine diagnostic groups (knee meniscus, knee ligament, multiple sclerosis, lumbar and cervical spine) MRI findings had a clear impact on treatment plans. CONCLUSION: This study demonstrates that in most diagnostic categories, MRI influences diagnosis and treatment. However, experimental studies are needed to prove that these diagnostic and therapeutic impacts lead to improved health. Hollingworth (2000)

  1. Diagnostic Accuracy of Ultrasonography in the Initial Evaluation of Patients with Penetrating Chest Trauma

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2014-03-01

    Full Text Available Introduction: Traumatic chest injuries (TCI are one of the most common causes of referring to the emergency departments, with high mortality and disability. This study was designed to evaluate the diagnostic accuracy of ultrasonography versus chest X ray (CXR in detection of hemo-pneumothorax for patients suffering penetrating TCI. Methods: The present cross-sectional study was performed to evaluate the diagnostic accuracy of ultrasonography in penetrating TCI victims referred to the emergency department of Shahid Kashani and Alzahra hospitals of Isfahan, Iran, from July 2012 to June 2013. Bedside ultrasonography and plain CXR was done on arrival and three hours after admission. The results of ultrasonography and radiography were separately evaluated by an emergency medicine specialist and a radiologist, who were blind to the aims of the study. Then, sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and kappa coefficient was considered to evaluate the accuracy of ultrasonography. Results: In this research 64 patients with penetrating chest trauma were assessed (98.4% male. The mean age of them was 25.6±8.5 years (rang: 13-65. The plain radiography revealed the eight (12.5 % cases of pneumothorax and one (1.6% hemothorax. The findings of primary ultrasonography also showed the same number of hemo-pneumothorax. Sensitivity and specificity of primary ultrasound in diagnosis of pneumothorax were 100% (95% Cl: 60.7- 100 and 100.0% (95% Cl, 92.0% to 100.0% and in detection of hemothorax were 100% (95% Cl: 50.5-100 and 100% (95% Cl: 92.8-100, respectively. Sensitivity and specificity of ultrasound in the third hour were 100% (95% Cl: 31.3-100 and 100% (95% Cl: 91.4-100, respectively. Conclusion: Findings of the present study have shown that ultrasonography has an acceptable diagnostic accuracy in the initial assessment of patients with penetrating chest trauma. However, because of its dependency on operator

  2. The evaluation of diagnostic value of the tumor markers: CCSA-2 and CEA in colorectal cancer.

    Science.gov (United States)

    Knychalski, Bartłomiej; Lukieńczuk, Tadeusz

    2012-02-01

    Finding the biomarker or biomarkers with high sensitivity and specificity in colorectal cancer, and thus a high diagnostic value will determine their clinical usefulness in clinical practice. An effective noninvasive blood test would be an ideal method to detect colorectal cancer. Discovered in 2007 a novel tumor marker CCSA-2 showes a promising results in patients with colorectal cancer. THE AIM OF THE STUDY was the evaluation of diagnostic and clinical value of a novel marker - colon cancer specific antigen-2 (CCSA-2) in colorectal adenocarcinoma in comparison to carcinoembryonic antigen (CEA) in patients operated during the years 2008 to 2010 at Wrocław Medical University 1st Department and Clinic of General, Gastroenterological and Endocrinologic Surgery. The study was performed on 40 patients with colorectal cancer and 40 patients in control group consisted of healthy subjects who had colonoscopy examinations with negative results (no pathology in the colon was found). The obtained results were statistically analyzed using nonparametric tests - Mann Whitney U and Kruskal-Wallis and Spearman's rank correlation coefficients. To determine the clinical value of CCSA-2 and CEA in those groups, their sensitivity and specifity was evaluated using ROC analysis. This analysis determines the accuracy and diagnostic value of both tests. There was a positive correlation between markers in patients with colorectal cancer and a statistically significant relationship according to which respondents with higher concentrations of CCSA-2 also have higher concentrations of CEA (R=0.754, ptumor markers increase and correlate with the clinical progression of the disease. Accuracy of CCSA-2 test using ROC analysis showed a slightly lower measurement of antigen CCSA-2 as diagnostic value in colorectal cancer in comparison to measurement of antigen CEA (accuracy of tests: CCSA-2 - 52%, CEA - 60%). CCSA-2 as a single tumor marker has a low diagnostic value in colorectal cancer because

  3. Paradigm Shifts in Ophthalmic Diagnostics.

    Science.gov (United States)

    Sebag, J; Sadun, Alfredo A; Pierce, Eric A

    2016-08-01

    Future advances in ophthalmology will see a paradigm shift in diagnostics from a focus on dysfunction and disease to better measures of psychophysical function and health. Practical methods to define genotypes will be increasingly important and non-invasive nanotechnologies are needed to detect molecular changes that predate histopathology. This is not a review nor meant to be comprehensive. Specific topics have been selected to illustrate the principles of important paradigm shifts that will influence the future of ophthalmic diagnostics. It is our impression that future evaluation of vision will go beyond visual acuity to assess ocular health in terms of psychophysical function. The definition of disease will incorporate genotype into what has historically been a phenotype-centric discipline. Non-invasive nanotechnologies will enable a paradigm shift from disease detection on a cellular level to a sub-cellular molecular level. Vision can be evaluated beyond visual acuity by measuring contrast sensitivity, color vision, and macular function, as these provide better insights into the impact of aging and disease. Distortions can be quantified and the psychophysical basis of vision can be better evaluated than in the past by designing tests that assess particular macular cell function(s). Advances in our understanding of the genetic basis of eye diseases will enable better characterization of ocular health and disease. Non-invasive nanotechnologies can assess molecular changes in the lens, vitreous, and macula that predate visible pathology. Oxygen metabolism and circulatory physiology are measurable indices of ocular health that can detect variations of physiology and early disease. This overview of paradigm shifts in ophthalmology suggests that the future will see significant improvements in ophthalmic diagnostics. The selected topics illustrate the principles of these paradigm shifts and should serve as a guide to further research and development. Indeed

  4. Applications of ROC analysis in diagnostic image evaluation

    International Nuclear Information System (INIS)

    Metz, C.E.

    1979-01-01

    The need for Receiver Operating Characteristic (ROC) analysis is indicated by a discussion of the limitations of accuracy and of sensitivity and specificity as indices of diagnostic detection or discrmination performance. The concept of a variable decision threshold is shown to lead in a natural way to the ROC curve as a means for specifying diagnostic performance. Practical techniques for measuring ROC curves are described, and directions for possible generalizations of conventional ROC analysis are indicated

  5. A one-versus-all class binarization strategy for bearing diagnostics of concurrent defects.

    Science.gov (United States)

    Ng, Selina S Y; Tse, Peter W; Tsui, Kwok L

    2014-01-13

    In bearing diagnostics using a data-driven modeling approach, a concern is the need for data from all possible scenarios to build a practical model for all operating conditions. This paper is a study on bearing diagnostics with the concurrent occurrence of multiple defect types. The authors are not aware of any work in the literature that studies this practical problem. A strategy based on one-versus-all (OVA) class binarization is proposed to improve fault diagnostics accuracy while reducing the number of scenarios for data collection, by predicting concurrent defects from training data of normal and single defects. The proposed OVA diagnostic approach is evaluated with empirical analysis using support vector machine (SVM) and C4.5 decision tree, two popular classification algorithms frequently applied to system health diagnostics and prognostics. Statistical features are extracted from the time domain and the frequency domain. Prediction performance of the proposed strategy is compared with that of a simple multi-class classification, as well as that of random guess and worst-case classification. We have verified the potential of the proposed OVA diagnostic strategy in performance improvements for single-defect diagnosis and predictions of BPFO plus BPFI concurrent defects using two laboratory-collected vibration data sets.

  6. A One-Versus-All Class Binarization Strategy for Bearing Diagnostics of Concurrent Defects

    Directory of Open Access Journals (Sweden)

    Selina S. Y. Ng

    2014-01-01

    Full Text Available In bearing diagnostics using a data-driven modeling approach, a concern is the need for data from all possible scenarios to build a practical model for all operating conditions. This paper is a study on bearing diagnostics with the concurrent occurrence of multiple defect types. The authors are not aware of any work in the literature that studies this practical problem. A strategy based on one-versus-all (OVA class binarization is proposed to improve fault diagnostics accuracy while reducing the number of scenarios for data collection, by predicting concurrent defects from training data of normal and single defects. The proposed OVA diagnostic approach is evaluated with empirical analysis using support vector machine (SVM and C4.5 decision tree, two popular classification algorithms frequently applied to system health diagnostics and prognostics. Statistical features are extracted from the time domain and the frequency domain. Prediction performance of the proposed strategy is compared with that of a simple multi-class classification, as well as that of random guess and worst-case classification. We have verified the potential of the proposed OVA diagnostic strategy in performance improvements for single-defect diagnosis and predictions of BPFO plus BPFI concurrent defects using two laboratory-collected vibration data sets.

  7. Early evaluation of a second generation information monitoring and diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kinney, Satkartar; Bourassa, Norman; Xu, Peng; Haves, Philip; Kinney, Kristopher; Shockman, Christine

    2002-03-25

    Private sector commercial office buildings are challenging environments for energy efficiency projects. This challenge is related to the complexity of business environments that involve ownership, operation, and tenant relationships. Whether it is poor quality design, inefficient operations, degradation of equipment over time, or merely the increasing use of energy by tenants and inattention from landlords, commercial office building energy use continues to increase. This research project was developed to examine the environment for building operations and identify causes of inefficient use of energy related to technical and organizational issues. This report discusses a second-generation Information Monitoring and Diagnostic System (IMDS) installed at a leased office building in Sacramento, California. The report begins with a brief summary of the IMDS research at the previous building, followed by a discussion of the building selection process, the IMDS design and installation, recent use of the IMDS, costs and benefits, and fault detection and diagnostic research using the IMDS. A web site describes the IMDS in detail (see imds.lbl.gov). The underlying principle of this research project is that high quality building performance data can help show where energy is being used and how buildings systems actually perform is an important first step toward improving building energy efficiency. The project utilizes a high-quality monitoring system that has been developed during the past decade by a partnership between LBNL and private industry. This research project has been successful in demonstrating that the IMDS is tremendously valuable to the building operators at the Sacramento site. The building operators not only accept the technology, but it has become the core of their day-to-day building control concepts. The innovative property management company, Jones Lang LaSalle, is interested in installing more sites to determine if the system could provide an economic

  8. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  9. Impacts of dairy diagnostic teams on herd performance.

    Science.gov (United States)

    Weinand, D; Conlin, B J

    2003-05-01

    This study evaluated impacts of educational diagnostic teams of consultants used to transfer technology to dairy farms. Herd management performance changes were measured by comparing Dairy Herd Improvement data from 38 project farms to data from herds that were geographical contemporaries. The value of focused goals for effecting change was also assessed. Interviews provided producers' perception of project outcomes and insight on organization and conduct of dairy diagnostic teams. Changes observed in project herds were small compared with controls with tendencies for increased herd size and improved milk production per cow. Focused goals had greater impacts on increasing herd size, milk per cow, first lactation peak milk, reducing age at first calving, and percentages of cows with subclinical mastitis. Time, money, facility limitations, labor, and alternative priorities were the most cited constraints to implementing changes. Satisfaction scores of producers were significantly related to the degree that team recommendations were followed. Improved attitudes, quality of life, and financial well-being were benefits listed by a majority of producers from participation in the project. If similar projects were to be offered, 83% said they would participate again, and 69% indicated they would pay at least some of the costs. Project farms served as demonstration farms for 1930 other producers in their respective locales, resulting in a multiplier effect of original advice given by consultant teams. Suggestions by farmer participants for improvements in dairy diagnostic teams included needs for at least some unbiased team members, more frequent meetings, more follow-up on recommendations, and consistency of recommendations with family goals.

  10. Improvement of the bandwidth of the transient digitizers in the LIDAR Thomson scattering diagnostic on JET

    International Nuclear Information System (INIS)

    Kristensen, E.

    1990-06-01

    The main limitation on the spatial resolution of the LIDAR Thomson scattering diagnostic on the JET tokamak is due to the narrow bandwidth of the detection system. The transient digitizers, Tektronik 7912AD, are the main contributors to the narrow bandwidth. It is shown how the digitizers can be modified to improve the response time from approx. 480 to 410 ps. (author)

  11. Sensitivity and specificity of proposed DSM-5 diagnostic criteria for autism spectrum disorder.

    Science.gov (United States)

    McPartland, James C; Reichow, Brian; Volkmar, Fred R

    2012-04-01

    This study evaluated the potential impact of proposed DSM-5 diagnostic criteria for autism spectrum disorder (ASD). The study focused on a sample of 933 participants evaluated during the DSM-IV field trial; 657 carried a clinical diagnosis of an ASD, and 276 were diagnosed with a non-autistic disorder. Sensitivity and specificity for proposed DSM-5 diagnostic criteria were evaluated using field trial symptom checklists as follows: individual field trial checklist items (e.g., nonverbal communication); checklist items grouped together as described by a single DSM-5 symptom (e.g., nonverbal and verbal communication); individual DSM-5 criterion (e.g., social-communicative impairment); and overall diagnostic criteria. When applying proposed DSM-5 diagnostic criteria for ASD, 60.6% (95% confidence interval: 57%-64%) of cases with a clinical diagnosis of an ASD met revised DSM-5 diagnostic criteria for ASD. Overall specificity was high, with 94.9% (95% confidence interval: 92%-97%) of individuals accurately excluded from the spectrum. Sensitivity varied by diagnostic subgroup (autistic disorder = 0.76; Asperger's disorder = 0.25; pervasive developmental disorder-not otherwise specified = 0.28) and cognitive ability (IQ criteria could substantially alter the composition of the autism spectrum. Revised criteria improve specificity but exclude a substantial portion of cognitively able individuals and those with ASDs other than autistic disorder. A more stringent diagnostic rubric holds significant public health ramifications regarding service eligibility and compatibility of historical and future research. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  12. Integrating empowerment evaluation and quality improvement to achieve healthcare improvement outcomes

    Science.gov (United States)

    Wandersman, Abraham; Alia, Kassandra Ann; Cook, Brittany; Ramaswamy, Rohit

    2015-01-01

    While the body of evidence-based healthcare interventions grows, the ability of health systems to deliver these interventions effectively and efficiently lags behind. Quality improvement approaches, such as the model for improvement, have demonstrated some success in healthcare but their impact has been lessened by implementation challenges. To help address these challenges, we describe the empowerment evaluation approach that has been developed by programme evaluators and a method for its application (Getting To Outcomes (GTO)). We then describe how GTO can be used to implement healthcare interventions. An illustrative healthcare quality improvement example that compares the model for improvement and the GTO method for reducing hospital admissions through improved diabetes care is described. We conclude with suggestions for integrating GTO and the model for improvement. PMID:26178332

  13. Leadership for health improvement--implementation and evaluation.

    Science.gov (United States)

    Carr, Susan M; Carr, Sue; Lhussier, Monique; Reynolds, Joanna; Hunter, David J; Hannaway, Catherine

    2009-01-01

    The purpose of this paper is to present a co-authored reflection on the health improvement leadership development programme and the key evaluation messages derived from piloting in an English National Health Service region. It highlights the specific attributes of this approach to health improvement leadership development and clarifies health improvement development issues. Appreciative inquiry and soft systems methodology are combined in an evaluation approach designed to capture individual as well as organisation learning and how it impacts on leadership in specific contexts. The evaluation exposes the health improvement leadership needs of a multi-organisation cohort, offers some explanations for successful achievement of learning needs while also exposing of the challenges and paradoxes faced in this endeavour. There are limited reported templates of how to develop leadership for health improvement. This paper details a whole systems approach, acknowledging the impact of context on leadership and an approach to evaluating such complex initiatives.

  14. Improvements in diagnostic tools for early detection of psoriatic arthritis.

    Science.gov (United States)

    D'Angelo, Salvatore; Palazzi, Carlo; Gilio, Michele; Leccese, Pietro; Padula, Angela; Olivieri, Ignazio

    2016-11-01

    Psoriatic arthritis (PsA) is a heterogeneous chronic inflammatory disease characterized by a wide clinical spectrum. The early diagnosis of PsA is currently a challenging topic. Areas covered: The literature was extensively reviewed for studies addressing the topic area "diagnosis of psoriatic arthritis". This review will summarize improvements in diagnostic tools, especially referral to the rheumatologist, the role of patient history and clinical examination, laboratory tests, and imaging techniques in getting an early and correct diagnosis of PsA. Expert commentary: Due to the heterogeneity of its expression, PsA may be easily either overdiagnosed or underdiagnosed. A diagnosis of PsA should be taken into account every time a patient with psoriasis or a family history of psoriasis shows peripheral arthritis, especially if oligoarticular or involving the distal interphalangeal joints, enthesitis or dactylitis. Magnetic resonance imaging and ultrasonography are useful for diagnosing PsA early, particularly when isolated enthesitis or inflammatory spinal pain occur.

  15. Diagnostic accuracy of fine needle aspiration cytology of thyroid and evaluation of discordant cases

    International Nuclear Information System (INIS)

    Sharma, Ch.

    2015-01-01

    The main role of fine needle aspiration cytology (FNAC) lies in differentiating between a malignant and benign thyroid nodule. It greatly influences the treatment decision. The current study was undertaken to evaluate the cytology–histopathology correlation and to analyze the cause of diagnostic errors with an eventual aim to improve diagnostic accuracy. Materials and Methods This is a retrospective study comparing cytology and corresponding histopathology report in 724 thyroid cases. The statistical analysis included false positive rate, false negative rate, sensitivity, specificity, positive predictive value, negative predictive value and accuracy. Results On cytological examination, 635/724 were reported as benign, 68 malignant and 21 suspicious. On histopathological examination, 626/635 cases were confirmed as benign but there were 9 discordant cases. Among the other cases histopathology diagnosis of malignancy matched in 66/68 and 11/21 cases. Diagnosis correlated in 703/724 cases (97%) [p < 0.001]. False positive and false negative rates were 1.9% and 10.5%, respectively. The sensitivity and specificity were 89.5% and 98%, respectively. The positive predictive value was 84.6% and negative predictive value was 98.6%. Accuracy of FNA was 97%. Conclusion In spite of high accuracy of FNAC in differentiating between a benign and malignant lesion, certain pitfalls should be kept in mind. The common false negative diagnoses were follicular pattern cases which constitute a ‘gray zone’, cystic papillary thyroid carcinoma (PTC) and papillary micro carcinoma. The reason for false positive diagnoses was the occurrence of nuclear features characteristic of PTC in other thyroid lesions. Awareness of pathologist regarding these pitfalls can minimize false negative/positive diagnoses

  16. Improved sonothrombolysis from a modified diagnostic transducer delivering impulses containing a longer pulse duration.

    Science.gov (United States)

    Wu, Juefei; Xie, Feng; Kumar, Tanmay; Liu, Jinjin; Lof, John; Shi, William; Everbach, E Carr; Porter, Thomas R

    2014-07-01

    Although guided high-mechanical-index (MI) impulses from a diagnostic ultrasound transducer have been used in preclinical studies to dissolve coronary arterial and microvascular thrombi in the presence of intravenously infused microbubbles, it is possible that pulse durations (PDs) longer than that used for diagnostic imaging may further improve the effectiveness of this approach. By use of an established in vitro model flow system, a total of 90 occlusive porcine arterial thrombi (thrombus age: 3-4 h) within a vascular mimicking system were randomized to 10-min treatments with two different PDs (5 and 20 μs) using a Philips S5-1 transducer (1.6-MHz center frequency) at a range of MIs (from 0.2 to 1.4). All impulses were delivered in an intermittent fashion to permit microbubble replenishment within the thrombosed vessel. Diluted lipid-encapsulated microbubbles (0.5% Definity) were infused during the entire treatment period. A tissue-mimicking phantom 5 cm thick was placed between the transducer and thrombosed vessel to mimic transthoracic attenuation. Two 20-MHz passive cavitation detection systems were placed confocal to the insonified vessel to assess for inertial cavitational activity. Percentage thrombus dissolution was calculated by weighing the thrombi before and after each treatment. Percentage thrombus dissolution was significantly higher with a 20-μs PD already at the 0.2 and 0.4 MI therapeutic impulses (54 ± 12% vs. 33 ± 17% and 54 ± 22% vs. 34 ± 17%, p cavitation detection systems detected only low intensities of inertial cavitation. At higher MI settings and 20-μs PDs, percentage thrombus dissolution decreased most likely from high-intensity cavitation shielding of the thrombus. Slightly prolonging the PD on a diagnostic transducer improves the degree of sonothrombolysis that can be achieved without fibrinolytic agents at a lower mechanical index. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc

  17. Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge

    International Nuclear Information System (INIS)

    Shen Yongjun; Lei Lecheng; Zhang Xingwang; Zhou Minghua; Zhang Yi

    2008-01-01

    Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 x 10 -9 mol/J and 1.95 x 10 -9 mol/J, respectively

  18. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    Science.gov (United States)

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  19. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  20. A systematic review and economic evaluation of diagnostic strategies for Lynch syndrome.

    Science.gov (United States)

    Snowsill, Tristan; Huxley, Nicola; Hoyle, Martin; Jones-Hughes, Tracey; Coelho, Helen; Cooper, Chris; Frayling, Ian; Hyde, Chris

    2014-09-01

    Lynch syndrome (LS) is an inherited autosomal dominant disorder characterised by an increased risk of colorectal cancer (CRC) and other cancers, and caused by mutations in the deoxyribonucleic acid (DNA) mismatch repair genes. To evaluate the accuracy and cost-effectiveness of strategies to identify LS in newly diagnosed early-onset CRC patients (aged strategies for individuals in whom LS is identified. Systematic reviews were conducted of the test accuracy of microsatellite instability (MSI) testing or immunohistochemistry (IHC) in individuals with CRC at risk of LS, and of economic evidence relating to diagnostic strategies for LS. Reviews were carried out in April 2012 (test accuracy); and in February 2012, repeated in February 2013 (economic evaluations). Databases searched included MEDLINE (1946 to April week 3, 2012), EMBASE (1980 to week 17, 2012) and Web of Science (inception to 30 April 2012), and risk of bias for test accuracy was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) quality appraisal tool. A de novo economic model of diagnostic strategies for LS was developed. Inconsistencies in study designs precluded pooling of diagnostic test accuracy results from a previous systematic review and nine subsequent primary studies. These were of mixed quality, with significant methodological concerns identified for most. IHC and MSI can both play a part in diagnosing LS but neither is gold standard. No UK studies evaluated the cost-effectiveness of diagnosing and managing LS, although studies from other countries generally found some strategies to be cost-effective compared with no testing. The de novo model demonstrated that all strategies were cost-effective compared with no testing at a threshold of £20,000 per quality-adjusted life-year (QALY), with the most cost-effective strategy utilising MSI and BRAF testing [incremental cost-effectiveness ratio (ICER) = £5491 per QALY]. The maximum health benefit to the

  1. Diagnostic Evaluation of Ozone Production and Horizontal Transport in a Regional Photochemical Air Quality Modeling System

    Science.gov (United States)

    A diagnostic model evaluation effort has been performed to focus on photochemical ozone formation and the horizontal transport process since they strongly impact the temporal evolution and spatial distribution of ozone (O3) within the lower troposphere. Results from th...

  2. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    Science.gov (United States)

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of

  3. Realization of process improvement at a diagnostic radiology department with aid of simulation modeling.

    Science.gov (United States)

    Oh, Hong-Choon; Toh, Hong-Guan; Giap Cheong, Eddy Seng

    2011-11-01

    Using the classical process improvement framework of Plan-Do-Study-Act (PDSA), the diagnostic radiology department of a tertiary hospital identified several patient cycle time reduction strategies. Experimentation of these strategies (which included procurement of new machines, hiring of new staff, redesign of queue system, etc.) through pilot scale implementation was impractical because it might incur substantial expenditure or be operationally disruptive. With this in mind, simulation modeling was used to test these strategies via performance of "what if" analyses. Using the output generated by the simulation model, the team was able to identify a cost-free cycle time reduction strategy, which subsequently led to a reduction of patient cycle time and achievement of a management-defined performance target. As healthcare professionals work continually to improve healthcare operational efficiency in response to rising healthcare costs and patient expectation, simulation modeling offers an effective scientific framework that can complement established process improvement framework like PDSA to realize healthcare process enhancement. © 2011 National Association for Healthcare Quality.

  4. Method for Evaluating Information to Solve Problems of Control, Monitoring and Diagnostics

    Science.gov (United States)

    Vasil'ev, V. A.; Dobrynina, N. V.

    2017-06-01

    The article describes a method for evaluating information to solve problems of control, monitoring and diagnostics. It is necessary for reducing the dimensionality of informational indicators of situations, bringing them to relative units, for calculating generalized information indicators on their basis, ranking them by characteristic levels, for calculating the efficiency criterion of a system functioning in real time. The design of information evaluation system has been developed on its basis that allows analyzing, processing and assessing information about the object. Such object can be a complex technical, economic and social system. The method and the based system thereof can find a wide application in the field of analysis, processing and evaluation of information on the functioning of the systems, regardless of their purpose, goals, tasks and complexity. For example, they can be used to assess the innovation capacities of industrial enterprises and management decisions.

  5. Radiophotometric diagnostics of osteodystrophy in cows during early milking period

    International Nuclear Information System (INIS)

    Samotaev, A.A.

    1988-01-01

    Dynamic standard induced of the fifth caudal vertebra in practically healthy caws, on the base of which evaluation of skeletal clinical state is performed, are presented. It is ascertained that improved roentgena densitometry methods can be applied by specialists in diagnostics of diseases accompanied by a change in mineral saturation of bone tissue, for a more objective opinion concerning the skeletal state

  6. The experiences of health-related quality of life in patients with nonspecific symptoms who undergo a diagnostic evaluation for cancer: a qualitative interview study.

    Science.gov (United States)

    Moseholm, Ellen; Lindhardt, Bjarne Oerskov; Rydahl-Hansen, Susan

    2017-09-01

    The diagnostic phase of cancer can affect health-related quality of life (HRQoL). The aim of this study was to investigate how patients with nonspecific symptoms experience HRQoL while undergoing diagnostic evaluations for cancer. Twenty-one participants who had completed a fast-track evaluation for possible cancer at one of three hospitals in the Capital Region, Denmark were interviewed 2-4 weeks after completing diagnostic evaluations. The interviews were semi-structured and were supported by an interview guide based on the same themes as in The European Organisation for Research and Treatment of Cancer Quality of Life questionnaire (EORCT-QLQ-C30). Data analysis was based on qualitative content analysis by Krippendorff. The analysis generated six categories: symptoms, physical-, role-, emotional-, cognitive- and social functioning, and the diagnostic fast-track experience. From these categories, a main theme was identified: Health-related quality of life is not solely affected by the diagnostic process. The results provide a comprehensive understanding of HRQoL in the diagnostic phase of possible cancer, which can be used not only to enhance evidence-based care, but also in the interpretation of the EORTC-QLQ-C30 scores. Psycho-social support with a focus on individual informational needs during the diagnostic phase may be warranted. © 2016 Nordic College of Caring Science.

  7. A diagnostic methodology for refrigerating systems; Methodologie de diagnostic des installations frigorifiques

    Energy Technology Data Exchange (ETDEWEB)

    Vrinat, G. [Association Francaise du Froid (AFF), 75 - Paris (France)

    1997-12-31

    A diagnostic methodology for refrigerating machines, equipment and plants has been defined and evaluated for EDF, the French national power utility and ADEME, the French Agency for Energy Conservation, in the framework of energy conservation objectives: the diagnostic method should enable to identify malfunctions, assess the cost efficiency of the equipment, identify limiting factors, and consider corrective measures

  8. Practical recommendations for the evaluation of improvement initiatives

    Science.gov (United States)

    Parry, Gareth; Coly, Astou; Goldmann, Don; Rowe, Alexander K; Chattu, Vijay; Logiudice, Deneil; Rabrenovic, Mihajlo; Nambiar, Bejoy

    2018-01-01

    Abstract A lack of clear guidance for funders, evaluators and improvers on what to include in evaluation proposals can lead to evaluation designs that do not answer the questions stakeholders want to know. These evaluation designs may not match the iterative nature of improvement and may be imposed onto an initiative in a way that is impractical from the perspective of improvers and the communities with whom they work. Consequently, the results of evaluations are often controversial, and attribution remains poorly understood. Improvement initiatives are iterative, adaptive and context-specific. Evaluation approaches and designs must align with these features, specifically in their ability to consider complexity, to evolve as the initiative adapts over time and to understand the interaction with local context. Improvement initiatives often identify broadly defined change concepts and provide tools for care teams to tailor these in more detail to local conditions. Correspondingly, recommendations for evaluation are best provided as broad guidance, to be tailored to the specifics of the initiative. In this paper, we provide practical guidance and recommendations that funders and evaluators can use when developing an evaluation plan for improvement initiatives that seeks to: identify the questions stakeholders want to address; develop the initial program theory of the initiative; identify high-priority areas to measure progress over time; describe the context the initiative will be applied within; and identify experimental or observational designs that will address attribution. PMID:29447410

  9. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won [Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of); Park, Seong Jin [Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of)

    2012-06-15

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  10. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    International Nuclear Information System (INIS)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won; Park, Seong Jin

    2012-01-01

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  11. Contrast-enhanced spectral mammography improves diagnostic accuracy in the symptomatic setting.

    Science.gov (United States)

    Tennant, S L; James, J J; Cornford, E J; Chen, Y; Burrell, H C; Hamilton, L J; Girio-Fragkoulakis, C

    2016-11-01

    To assess the diagnostic accuracy of contrast-enhanced spectral mammography (CESM), and gauge its "added value" in the symptomatic setting. A retrospective multi-reader review of 100 consecutive CESM examinations was performed. Anonymised low-energy (LE) images were reviewed and given a score for malignancy. At least 3 weeks later, the entire examination (LE and recombined images) was reviewed. Histopathology data were obtained for all cases. Differences in performance were assessed using receiver operator characteristic (ROC) analysis. Sensitivity, specificity, and lesion size (versus MRI or histopathology) differences were calculated. Seventy-three percent of cases were malignant at final histology, 27% were benign following standard triple assessment. ROC analysis showed improved overall performance of CESM over LE alone, with area under the curve of 0.93 versus 0.83 (p<0.025). CESM showed increased sensitivity (95% versus 84%, p<0.025) and specificity (81% versus 63%, p<0.025) compared to LE alone, with all five readers showing improved accuracy. Tumour size estimation at CESM was significantly more accurate than LE alone, the latter tending to undersize lesions. In 75% of cases, CESM was deemed a useful or significant aid to diagnosis. CESM provides immediately available, clinically useful information in the symptomatic clinic in patients with suspicious palpable abnormalities. Radiologist sensitivity, specificity, and size accuracy for breast cancer detection and staging are all improved using CESM as the primary mammographic investigation. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Comparing the American and European diagnostic guidelines for cystic fibrosis: same disease, different language?

    Science.gov (United States)

    Ooi, Chee Y; Dupuis, Annie; Ellis, Lynda; Jarvi, Keith; Martin, Sheelagh; Gonska, Tanja; Dorfman, Ruslan; Kortan, Paul; Solomon, Melinda; Tullis, Elizabeth; Durie, Peter R

    2012-07-01

    The American and European cystic fibrosis (CF) guidelines recommend different diagnostic criteria. This study assessed diagnostic concordance between these recommendations. Subjects with single organ manifestations suggestive of CF (chronic sinopulmonary disease (RESP), chronic/recurrent pancreatitis (PANC) or obstructive azoospermia (AZOOSP)) were prospectively evaluated by sweat test, nasal potential difference and genotyping. Concordance in diagnostic outcomes between the two algorithms was measured using observed agreement and κ statistics. A total of 208 subjects were evaluated. Observed agreement was 84.8% and level of agreement was excellent (κ=0.87) between the American and European recommendations. The RESP phenotype was associated with the highest degree of concordance (observed agreement ≥90%, κ=0.92) compared with the PANC (observed agreement 86%, κ=0.65) and AZOOSP (observed agreement 80%, κ=0.87) phenotypes. Incorporation of nasal potential difference into the American algorithm failed to improve the overall degree of concordance (good agreement level; κ=0.75); the level of agreement was unchanged in RESP and PANC subjects, but reduced in AZOOSP subjects (from excellent to good). Extensive genotyping had limited clinical utility in the diagnosis of CF in both algorithms. Despite inconsistencies between the American and European diagnostic recommendations, concordance in diagnostic outcomes among subjects presenting with single organ manifestations of CF was good to excellent. These diagnostic guidelines provide guidance and promote rigorous evaluation for the diagnosis of CF but neither guideline should be regarded as dogma.

  13. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  14. Diagnostic accuracy of postmortem imaging vs autopsy—A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Anders, E-mail: anders.eriksson@rmv.se [Section of Forensic Medicine, Dept of Community Medicine and Rehabilitation, Umeå University, PO Box 7016, SE-907 12 Umeå (Sweden); Gustafsson, Torfinn [Section of Forensic Medicine, Dept of Community Medicine and Rehabilitation, Umeå University, PO Box 7016, SE-907 12 Umeå (Sweden); Höistad, Malin; Hultcrantz, Monica [Swedish Agency for Health Technology Assessment and Assessment of Social Services, PO Box 3657, SE-103 59 Stockholm (Sweden); Department of Learning, Informatics, Management and Ethics, Karolinska Institutet, SE-171 77 Stockholm (Sweden); Jacobson, Stella; Mejare, Ingegerd [Swedish Agency for Health Technology Assessment and Assessment of Social Services, PO Box 3657, SE-103 59 Stockholm (Sweden); Persson, Anders [Department of Medical and Health Sciences, Center for Medical Image Science and Visualization (CMIV), Linköping University, SE-581 85, Linköping Sweden (Sweden)

    2017-04-15

    Highlights: • The search generated 340 possibly relevant publications, of which 49 were assessed as having high risk of bias and 22 as moderate risk. • Due to considerable heterogeneity of included studies it was impossible to estimate the diagnostic accuracy of the various findings. • Future studies need larger materials and improved planning and methodological quality, preferentially from multi-center studies. - Abstract: Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity – in populations, techniques, analyses and reporting – of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem

  15. Diagnostic accuracy of postmortem imaging vs autopsy—A systematic review

    International Nuclear Information System (INIS)

    Eriksson, Anders; Gustafsson, Torfinn; Höistad, Malin; Hultcrantz, Monica; Jacobson, Stella; Mejare, Ingegerd; Persson, Anders

    2017-01-01

    Highlights: • The search generated 340 possibly relevant publications, of which 49 were assessed as having high risk of bias and 22 as moderate risk. • Due to considerable heterogeneity of included studies it was impossible to estimate the diagnostic accuracy of the various findings. • Future studies need larger materials and improved planning and methodological quality, preferentially from multi-center studies. - Abstract: Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity – in populations, techniques, analyses and reporting – of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem

  16. Evaluation of outpatients with suspected pulmonary tuberculosis in a high HIV prevalence setting in Ethiopia: clinical, diagnostic and epidemiological characteristics.

    Science.gov (United States)

    Bruchfeld, Judith; Aderaye, Getachew; Palme, Ingela Berggren; Bjorvatn, Bjarne; Britton, Sven; Feleke, Yewenhareg; Källenius, Gunilla; Lindquist, Lars

    2002-01-01

    In a setting with a high prevalence of HIV we studied (i) the prevalence of pulmonary tuberculosis (PTB) and HIV; (ii) clinical and epidemiological characteristics of PTB; and (iii) the usefulness of standard procedures for diagnosing PTB. Of 509 consecutive outpatients evaluated on clinical suspicion of PTB in Addis Ababa, 33.0% were culture-verified as having PTB. PTB patients, non-TB patients and controls were HIV-1-positive in 57.1%, 38.5% and 8.3% of cases, respectively. Predictors for culture-verified PTB were age infection. Diagnosis of PTB based on clinical symptoms, sputum microscopy for acid-fast bacilli and chest radiography was sensitive (86.7%) but unspecific (64.1%). In HIV-positive patients both sensitivity and specificity were significantly lower (p infections are often misinterpreted as smear-negative PTB. HIV screening is therefore warranted not only in cases of verified TB but also as part of the diagnostic work-up in patients with respiratory symptoms suggestive of PTB. Also, increased awareness of, and improved diagnostic tools for, HIV-related pulmonary infections other than PTB are required, together with algorithms for patients with suspected PTB.

  17. Evaluation of diagnostic thresholds dependability for tribologic signals received in the environment disturbed by vibroacoustic and functional signals

    Directory of Open Access Journals (Sweden)

    Lindstedt Paweł

    2015-12-01

    Full Text Available Determination of dependable diagnostic thresholds for tribologic signals received e.g. from antifriction bearings (in particular for insufficient number of measurements, only 4÷5 is a really difficult task due to complexity of working environment where such bearings are operated. Typical working environment for such objects must take account for operation time under various working conditions and accompanying (and disturbing signals, e.g. vibroacoustic ones. The sought assessment of the relationship between diagnostic signals and environmental noise can be determined from convolution of both diagnostic and environments signals that make up the complete set of received information. The convolution of these two series of signals can be obtained from an algorithm based on the Cauchy product. Then one has to find the coherence factor and the square of amplitude gain for the set of diagnostic signals with reference to various sets of signals received from environment, which makes it possible to evaluate cohesion of the investigated series of signals, thus their suitability to determine diagnostic threshold for tribologic signals intended for the analysis.

  18. Experimental guinea pig model of dermatophytosis: a simple and useful tool for the evaluation of new diagnostics and antifungals

    DEFF Research Database (Denmark)

    Saunte, D.M.; Hasselby, J.P.; Brillowska-Dabrowska, A.

    2008-01-01

    The aim of this study was to establish a simple guinea pig model for the purpose of evaluating diagnostic principles and treatment modalities for dermatophytic infections. The following variables were evaluated; pre-treatment of the skin by shaving versus tape stripping, Microsporum canis...

  19. [Cognitive errors in diagnostic decision making].

    Science.gov (United States)

    Gäbler, Martin

    2017-10-01

    Approximately 10-15% of our diagnostic decisions are faulty and may lead to unfavorable and dangerous outcomes, which could be avoided. These diagnostic errors are mainly caused by cognitive biases in the diagnostic reasoning process.Our medical diagnostic decision-making is based on intuitive "System 1" and analytical "System 2" diagnostic decision-making and can be deviated by unconscious cognitive biases.These deviations can be positively influenced on a systemic and an individual level. For the individual, metacognition (internal withdrawal from the decision-making process) and debiasing strategies, such as verification, falsification and rule out worst-case scenarios, can lead to improved diagnostic decisions making.

  20. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    International Nuclear Information System (INIS)

    Isa, Nor Ashidi Mat

    2015-01-01

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well

  1. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    Science.gov (United States)

    Isa, Nor Ashidi Mat

    2015-05-01

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well

  2. Towards intelligent diagnostic system employing integration of mathematical and engineering model

    Energy Technology Data Exchange (ETDEWEB)

    Isa, Nor Ashidi Mat [Imaging and Intelligent System Research Team (ISRT), School of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang (Malaysia)

    2015-05-15

    The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well

  3. Diagnostic X-ray equipment evaluation in Brazil

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Peixoto, J.E.; Reis, V.R.G.

    1980-01-01

    A survey of the diagnostic X-ray equipment in use in Brazil is presented. Procedures for testing radiation quality (kilovoltage and filtration), tube output, beam collimation and protection devices are described and results of tests are tabulated. (H.K.)

  4. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  5. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  6. Team building and diagnostic training

    International Nuclear Information System (INIS)

    Bulmer, S.

    1987-01-01

    While developing a commercial training program to improve teamwork in control room crews, General Electric's Nuclear Training Services made an important discovery. Traditional training methods for developing teamwork and enhancing diagnostics capabilities are incomplete. Traditional methods generally help, but fail to fulfill the long-term needs of most teams. Teamwork has been treated as a short-term performance problem. Traditional diagnostic training suffers from a similar problem. Too often, it covers only the basic principles of decision-making, ignoring the development of expert diagnostic capabilities. In response to this discovery, they have developed comprehensive training in Team Building and Diagnostics

  7. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    Science.gov (United States)

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (ppower Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; ppower Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  8. Evaluation of a new rapid diagnostic kit (FemExam) for bacterial vaginosis in patients with vaginal discharge syndrome in The Gambia

    NARCIS (Netherlands)

    West, Beryl; Morison, Linda; Schim van der Loeff, Maarten; Gooding, Euphemia; Awasana, Akum Aveika; Demba, Edward; Mayaud, Philippe

    2003-01-01

    Diagnosis of bacterial vaginosis (BV) in resource-poor primary health care settings is often overlooked; there is a need for a cheap, rapid, objective point-of-care diagnostic test. The goal was to determine the prevalence of BV and to evaluate the performance of a new commercial diagnostic test kit

  9. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings

  10. Integrating empowerment evaluation and quality improvement to achieve healthcare improvement outcomes.

    Science.gov (United States)

    Wandersman, Abraham; Alia, Kassandra Ann; Cook, Brittany; Ramaswamy, Rohit

    2015-10-01

    While the body of evidence-based healthcare interventions grows, the ability of health systems to deliver these interventions effectively and efficiently lags behind. Quality improvement approaches, such as the model for improvement, have demonstrated some success in healthcare but their impact has been lessened by implementation challenges. To help address these challenges, we describe the empowerment evaluation approach that has been developed by programme evaluators and a method for its application (Getting To Outcomes (GTO)). We then describe how GTO can be used to implement healthcare interventions. An illustrative healthcare quality improvement example that compares the model for improvement and the GTO method for reducing hospital admissions through improved diabetes care is described. We conclude with suggestions for integrating GTO and the model for improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Computed Tomography Perfusion Improves Diagnostic Accuracy in Acute Posterior Circulation Stroke.

    Science.gov (United States)

    Sporns, Peter; Schmidt, Rene; Minnerup, Jens; Dziewas, Rainer; Kemmling, André; Dittrich, Ralf; Zoubi, Tarek; Heermann, Philipp; Cnyrim, Christian; Schwindt, Wolfram; Heindel, Walter; Niederstadt, Thomas; Hanning, Uta

    2016-01-01

    Computed tomography perfusion (CTP) has a high diagnostic value in the detection of acute ischemic stroke in the anterior circulation. However, the diagnostic value in suspected posterior circulation (PC) stroke is uncertain, and whole brain volume perfusion is not yet in widespread use. We therefore studied the additional value of whole brain volume perfusion to non-contrast CT (NCCT) and CT angiography source images (CTA-SI) for infarct detection in patients with suspected acute ischemic PC stroke. This is a retrospective review of patients with suspected stroke in the PC in a database of our stroke center (n = 3,011) who underwent NCCT, CTA and CTP within 9 h after stroke onset and CT or MRI on follow-up. Images were evaluated for signs and pc-ASPECTS locations of ischemia. Three imaging models - A (NCCT), B (NCCT + CTA-SI) and C (NCCT + CTA-SI + CTP) - were compared with regard to the misclassification rate relative to gold standard (infarction in follow-up imaging) using the McNemar's test. Of 3,011 stroke patients, 267 patients had a suspected stroke in the PC and 188 patients (70.4%) evidenced a PC infarct on follow-up imaging. The sensitivity of Model C (76.6%) was higher compared with that of Model A (21.3%) and Model B (43.6%). CTP detected significantly more ischemic lesions, especially in the cerebellum, posterior cerebral artery territory and thalami. Our findings in a large cohort of consecutive patients show that CTP detects significantly more ischemic strokes in the PC than CTA and NCCT alone. © 2016 S. Karger AG, Basel.

  12. Development of an equipment diagnostic system that evaluates sensor drift

    International Nuclear Information System (INIS)

    Kanada, Masaki; Arita, Setsuo; Tada, Nobuo; Yokota, Katsuo

    2011-01-01

    The importance of condition monitoring technology for equipment has increased with the introduction of condition-based maintenance in nuclear power plants. We are developing a diagnostic system using process signals for plant equipment, such as pumps and motors. It is important to enable the diagnostic system to distinguish sensor drift and equipment failure. We have developed a sensor drift diagnostic method that combines some highly correlative sensor signals by using the MT (Mahalanobis-Taguchi) method. Furthermore, we have developed an equipment failure diagnostic method that measures the Mahalanobis distance from the normal state of equipment by the MT method. These methods can respectively detect sensor drift and equipment failure, but there are the following problems. In the sensor drift diagnosis, there is a possibility of misjudging the sensor drift when the equipment failure occurs and the process signal changes because the behavior of the process signal is the same as that of the sensor drift. Oppositely, in the equipment failure diagnosis, there is a possibility of misjudging the equipment failure when the sensor drift occurs because the sensor drift influences the change of process signal. To solve these problems, we propose a diagnostic method combining the sensor drift diagnosis and the equipment failure diagnosis by the MT method. Firstly, the sensor drift values are estimated by the sensor drift diagnosis, and the sensor drift is removed from the process signal. It is necessary to judge the validity of the estimated sensor drift values before removing the sensor drift from the process signal. We developed a method for judging the validity of the estimated sensor drift values by using the drift distribution based on the sensor calibration data. And then, the equipment failure is diagnosed by using the process signals after removal of the sensor drifts. To verify the developed diagnostic system, several sets of simulation data based on abnormal cases

  13. Evaluation of the diagnostic capacity of the DETEC-PC for the attract of iodine in thyroid

    International Nuclear Information System (INIS)

    Alonso A, D.; Arista R, E.; Alonso A, A.

    2006-01-01

    A comparative study whose main objective is the evaluation of the diagnoses capacity of the DETEC - PC, a detection-measurement system for the reception of iodine in thyroid, with it presumptive diagnostic is presented. To such effect a clinical essay was designed in which all the patients included in the study were evaluated using the new equipment (DETEC - PC) and the standard diagnoses procedure well-known for the initials RIA. The sample size was calculated in a such way that the percent of gross coincidence among both methods could be estimate with a precision of 1% at a trust level of 95%. In total 110 patients were included in the essay. For the analysis of the agreement in the diagnostic it was used the Kappa statistician. The obtained results showed a high grade of gross agreement and an agreement level among moderate and substantial when it was corrected by possible random agreement among both procedures. (Author)

  14. Diagnostic Value of CT Arthrography for Evaluation of Osteochondral Lesions at the Ankle

    Directory of Open Access Journals (Sweden)

    Jan S. Kirschke

    2016-01-01

    Full Text Available Background. To retrospectively determine the diagnostic value of computed tomography arthrography (CTA of the ankle in the evaluation of (osteochondral lesions in comparison to conventional magnetic resonance imaging (MRI and intraoperative findings. Methods. A total of N=79 patients had CTAs and MRI of the ankle; in 17/79 cases surgical reports with statements on cartilage integrity were available. Cartilage lesions and bony defects at talus and tibia were scored according to defect depth and size by two radiologists. Statistical analysis included sensitivity analyses and Cohen’s kappa calculations. Results. On CTA, 41/79 and 31/79 patients had full thickness cartilage defects at the talus and at the tibia, respectively. MRI was able to detect 54% of these defects. For the detection of full thickness cartilage lesions, interobserver agreement was substantial (0.72 ± 0.05 for CTA and moderate (0.55 ± 0.07 for MRI. In surgical reports, 88–92% and 46–62% of full thickness defects detected by CTA and MRI were described. CTA findings changed the further clinical management in 15.4% of cases. Conclusions. As compared to conventional MRI, CTA improves detection and visualization of cartilage defects at the ankle and is a relevant tool for treatment decisions in unclear cases.

  15. [Diagnostic evaluation of the developmental level in children identified at risk of delay through the Child Development Evaluation Test].

    Science.gov (United States)

    Rizzoli-Córdoba, Antonio; Campos-Maldonado, Martha Carmen; Vélez-Andrade, Víctor Hugo; Delgado-Ginebra, Ismael; Baqueiro-Hernández, César Iván; Villasís-Keever, Miguel Ángel; Reyes-Morales, Hortensia; Ojeda-Lara, Lucía; Davis-Martínez, Erika Berenice; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Sidonio-Aguayo, Beatriz; Palma-Tavera, Josuha Alexander; Muñoz-Hernández, Onofre

    The Child Development Evaluation (or CDE Test) was developed in Mexico as a screening tool for child developmental problems. It yields three possible results: normal, slow development or risk of delay. The modified version was elaborated using the information obtained during the validation study but its properties according to the base population are not known. The objective of this work was to establish diagnostic confirmation of developmental delay in children 16- to 59-months of age previously identified as having risk of delay through the CDE Test in primary care facilities. A population-based cross-sectional study was conducted in one Mexican state. CDE test was administered to 11,455 children 16- to 59-months of age from December/2013 to March/2014. The eligible population represented the 6.2% of the children (n=714) who were identified at risk of delay through the CDE Test. For inclusion in the study, a block randomization stratified by sex and age group was performed. Each participant included in the study had a diagnostic evaluation using the Battelle Development Inventory, 2 nd edition. From the 355 participants included with risk of delay, 65.9% were male and 80.2% were from rural areas; 6.5% were false positives (Total Development Quotient ˃90) and 6.8% did not have any domain with delay (Domain Developmental Quotient <80). The proportion of delay for each domain was as follows: communication 82.5%; cognitive 80.8%; social-personal 33.8%; motor 55.5%; and adaptive 41.7%. There were significant differences in the percentages of delay both by age and by domain/subdomain evaluated. In 93.2% of the participants, developmental delay was corroborated in at least one domain evaluated. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  16. Improvements to the ion Doppler spectrometer diagnostic on the HIT-SI experiments

    Science.gov (United States)

    Hossack, Aaron; Chandra, Rian; Everson, Chris; Jarboe, Tom

    2018-03-01

    An ion Doppler spectrometer diagnostic system measuring impurity ion temperature and velocity on the HIT-SI and HIT-SI3 spheromak devices has been improved with higher spatiotemporal resolution and lower error than previously described devices. Hardware and software improvements to the established technique have resulted in a record of 6.9 μs temporal and ≤2.8 cm spatial resolution in the midplane of each device. These allow Ciii and Oii flow, displacement, and temperature profiles to be observed simultaneously. With 72 fused-silica fiber channels in two independent bundles, and an f/8.5 Czerny-Turner spectrometer coupled to a video camera, frame rates of up to ten times the imposed magnetic perturbation frequency of 14.5 kHz were achieved in HIT-SI, viewing the upper half of the midplane. In HIT-SI3, frame rates of up to eight times the perturbation frequency were achieved viewing both halves of the midplane. Biorthogonal decomposition is used as a novel filtering tool, reducing uncertainty in ion temperature from ≲13 to ≲5 eV (with an instrument temperature of 8-16 eV) and uncertainty in velocity from ≲2 to ≲1 km/s. Doppler shift and broadening are calculated via the Levenberg-Marquardt algorithm, after which the errors in velocity and temperature are uniquely specified. Axisymmetric temperature profiles on HIT-SI3 for Ciii peaked near the inboard current separatrix at ≈40 eV are observed. Axisymmetric plasma displacement profiles have been measured on HIT-SI3, peaking at ≈6 cm at the outboard separatrix. Both profiles agree with the upper half of the midplane observable by HIT-SI. With its complete midplane view, HIT-SI3 has unambiguously extracted axisymmetric, toroidal current dependent rotation of up to 3 km/s. Analysis of the temporal phase of the displacement uncovers a coherent structure, locked to the applied perturbation. Previously described diagnostic systems could not achieve such results.

  17. Evaluation of pain in outpatient diagnostic hysteroscopy with gas

    Directory of Open Access Journals (Sweden)

    Daniela Barreto Fraguglia Quental Diniz

    2010-03-01

    Full Text Available Objective: To evaluate the intensity of pain reported by patients undergoing outpatient diagnostic hysteroscopy. Methods: Exam performed with a 5-mm lens hysteroscope, vaginal speculum, tenaculum and uterine distention with carbon dioxide gas. Before and after the examination, patients were interviewed to define, in a verbal scale from 0 to 10, pain values that they expected to feel and that they experienced after the end, and also if they would repeat it if indicated. Data were analyzed using Statistical Package for the Social Sciences 15.0, statistic significance was defined as p < 0.05 with a study power of 95%. Results: Fifty-eight patients were included with mean age of 50.9 years, with 32.8% at postmenopause and 6.9% nulliparous. Among those with previous deliveries, mean parity was 2.21 and at least one vaginal delivery had occurred in 63.8%. Only 24.1% of patients knew how the exam would be done, 62.1% needed an endometrial sample and the result was considered satisfactory in 89.7%. The means of expected and experienced pain were similar (6.0 versus 6.1, and 91.4% of women would repeat the hysteroscopy if necessary. The only factor associated with less pain after the exam was previous vaginal delivery, with a decrease of pain score from 7.1 to 5.5 (p = 0.03. Mean pain was significantly lower in those who agreed to repeat the exam (5.8 versus 9.4; p = 0.003. Conclusions: Outpatient diagnostic hysteroscopy with gas can be associated with moderate but tolerable discomfort and satisfactory results.

  18. FISH analysis for diagnostic evaluation of challenging melanocytic lesions.

    Science.gov (United States)

    Zimmermann, A K; Hirschmann, A; Pfeiffer, D; Paredes, B E; Diebold, J

    2010-09-01

    The differential diagnosis of malignant melanomas and atypical melanocytic nevi is still a diagnostic challenge. The currently accepted morphologic criteria show substantial interobserver variability, likewise immunohistochemical studies are often not able to discriminate these lesions reliably. Techniques that support diagnostic accuracy are of the greatest importance considering the growing incidence of malignant melanomas and their increase in younger patients. In this study we analyzed the feasibility of fluorescence in situ hybridization (FISH) analysis for the discrimination of malignant and benign melanocytic tumors. A panel of DNA probes was used to detect chromosomal aberrations of chromosomes 6 and 11. On a series of 5 clearly malignant and benign melanocytic tumors we confirmed the applicability of the test. Then we focused on examination of ambiguous melanocytic lesions, where atypical cells are often difficult to relocalize in the 4',6-Diamidino-2-phenylindol (DAPI)-fluorescence stain. FISH analyses were conducted on destained H&E-stained slides. By comparison of the DAPI-image with photos taken from the H&E stain, unambiguous assignment of the FISH results to the conspicuous groups of cells was possible. The results of FISH analysis were consistent with the conventional diagnosis in 11 of 14 small ambiguous lesions. Of the remaining 3 cases, 2 showed FISH-results close to the cut-off level. Comparison of FISH results on thin and thick sections revealed that the cut-off values have to be adapted for 2 microm destained sections. In conclusion, FISH analysis is a useful and applicable tool for assessment of even smallest melanocytic neoplasms, although there will remain unclear cases that cannot be solved even after additional FISH evaluation.

  19. Improved histopathological evaluation of gliomas using tissue fragments obtained by ultrasonic aspiration

    DEFF Research Database (Denmark)

    Neckelmann, K; Kristensen, B W; Schrøder, H D

    2004-01-01

    included in the biopsy removed for peroperative frozen section investigation. When the slides with Sonocut tissue fragments were analyzed, the probability of making the most malignant diagnosis increased from 81.3% - 99.1%, when slides from 1 - 5 paraffin blocks were analyzed, respectively. When subgroups...... of small, medium and big tumors were analyzed, it was found that only 2 paraffin blocks from small tumors need to be prepared to reach 98.3% probability of making the most malignant diagnosis, whereas 5 paraffin blocks from big tumors need to be prepared to reach a 96.8% probability. In conclusion......, the study shows that a limited amount of Sonocut ultrasonic tissue fragments improve the diagnostic evaluation of gliomas. These tissue fragments therefore must not be discarded. Only few paraffin blocks need to be prepared to reach close to 100% probability of making the most malignant diagnosis, reducing...

  20. Diagnostic validity of hematologic parameters in evaluation of massive pulmonary embolism.

    Science.gov (United States)

    Ates, Hale; Ates, Ihsan; Kundi, Harun; Yilmaz, Fatma Meric

    2017-09-01

    The aim of this study was to determine the hematologic parameter with the highest diagnostic differentiation in the identification of massive acute pulmonary embolism (APE). A retrospective study was performed on patients diagnosing with APE between June 2014 and June 2016. All radiological and laboratory parameters of patients were scanned through the electronic information management system of the hospital. PLR was obtained from the ratio of platelet count to lymphocyte count, NLR was obtained from the ratio of neutrophil count to lymphocyte count, WMR was obtained from white blood cell in mean platelet volume ratio, MPR was obtained from the ratio of mean platelet volume to platelet count, and RPR was obtained from the ratio of red distribution width to platelet count. Six hundred and thirty-nine patients consisting of 292 males (45.7%) and 347 females (54.3%) were included in the research. Independent predictors of massive risk as compared to sub-massive group were; pulmonary arterial systolic pressure (PASP) (OR=1.40; P=.001), PLR (OR=1.59; P<.001), NLR (OR=2.22; P<.001), WMR (OR=1.22; P<.001), MPR (OR=0.33; P<.001), and RPR (OR=0.68; P<.001). Upon evaluation of the diagnostic differentiation of these risk factors for massive APE by employing receiver operating characteristic curve analysis, it was determined that PLR (AUC±SE=0.877±0.015; P<.001), and NLR (AUC±SE=0.893±0.013; P<.001) have similar diagnostic differentiation in diagnosing massive APE and these two parameters are superior over PASP, MPR, WMR, and RPR. We determined that the levels of NLR and PLR are superior to other parameters in the determination of clinical severity in APE cases. © 2016 Wiley Periodicals, Inc.

  1. Advances in molecular-based diagnostics in meeting crop biosecurity and phytosanitary issues.

    Science.gov (United States)

    Schaad, Norman W; Frederick, Reid D; Shaw, Joe; Schneider, William L; Hickson, Robert; Petrillo, Michael D; Luster, Douglas G

    2003-01-01

    Awareness of crop biosecurity and phytosanitation has been heightened since 9/11 and the unresolved anthrax releases in October 2001. Crops are highly vulnerable to accidental or deliberate introductions of crop pathogens from outside U.S. borders. Strategic thinking about protection against deliberate or accidental release of a plant pathogen is an urgent priority. Rapid detection will be the key to success. This review summarizes recent progress in the development of rapid real-time PCR protocols and evaluates their effectiveness in a proposed nationwide network of diagnostic laboratories that will facilitate rapid diagnostics and improved communication.

  2. Evaluation of electromagnetic loads on various design options of the ITER diagnostic upper port plug during plasma disruptions

    International Nuclear Information System (INIS)

    Pak, Sunil; Ku, Duck Young; Oh, Dong-Keun; Jhang, Hogun; Kim, Duck-Hoi; Cheon, Mun-Seong; Seon, Chang Rae; Lee, Hyeon Gon; Pitcher, Spencer

    2011-01-01

    Electromagnetic (EM) loads due to eddy current and halo current during plasma disruptions are evaluated for the ITER diagnostic upper port plug. To reduce strong EM loads acting on the port plug fixed to the vacuum vessel like a cantilever beam, three design options have been considered: removal of the diagnostic first wall, slitting of the diagnostic shield module and recess of the port plug. The main focus of the present study is to examine the efficacy of these options in terms of EM loads on the upper port plug. It is found that making slits is more effective than removing the first wall. It is also shown that the upper port plug needs to be recessed to reduce the EM load induced by halo current.

  3. Advanced diagnostics and predictive maintenance to improve availability and reliability of ENEL plants

    Energy Technology Data Exchange (ETDEWEB)

    Cenci, V.; Ghironi, M.; Guidi, L.; Lauro, M.; Pestonesi, D. [ENEL (Italy). Generation and Energy Management Division

    2007-07-01

    This paper reviews the ENEL Generation and Energy Management strategy for diagnostics and predictive maintenance of power plants and provides a comprehensive description of effective applications and systems. Exploiting the most advanced information and communication technologies makes it possible to capture weak and hidden signals and powerful processing can be used to discover forewarning symptoms and identify anomalies both in the process and, above all, inside the devices. The following systems and applications are presented together with results and impact on plant profitability: expert system for the diagnostics of plant main machinery; advanced diagnostics of 'intelligent' fieldbus devices such as on/off valve motor-driven actuators, control-valve positioners and pneumatic actuators, transmitters; control loop and control valve diagnostics in order to investigate valve friction with an estimation of the residual time to failure; multisensorial diagnostics for coal transport and storage systems aimed at preventing firing and structural damages; and wireless sensor networks for the diagnostics of medium and small size components. 4 refs., 14 figs., 1 tab.

  4. Risk-adjusted capitation based on the Diagnostic Cost Group Model: an empirical evaluation with health survey information

    NARCIS (Netherlands)

    L.M. Lamers (Leida)

    1999-01-01

    textabstractOBJECTIVE: To evaluate the predictive accuracy of the Diagnostic Cost Group (DCG) model using health survey information. DATA SOURCES/STUDY SETTING: Longitudinal data collected for a sample of members of a Dutch sickness fund. In the Netherlands the sickness

  5. Conventional 3T brain MRI and diffusion tensor imaging in the diagnostic workup of early stage parkinsonism

    International Nuclear Information System (INIS)

    Meijer, Frederick J.A.; Rumund, Anouke van; Tuladhar, Anil M.; Aerts, Marjolein B.; Titulaer, Imke; Esselink, Rianne A.J.; Bloem, Bastiaan R.; Verbeek, Marcel M.; Goraj, Bozena

    2015-01-01

    The aim of this study is to evaluate whether the diagnostic accuracy of 3 T brain MRI is improved by region of interest (ROI) measures of diffusion tensor imaging (DTI), to differentiate between neurodegenerative atypical parkinsonism (AP) and Parkinson's disease (PD) in early stage parkinsonism. We performed a prospective observational cohort study of 60 patients presenting with early stage parkinsonism and initial uncertain diagnosis. At baseline, patients underwent a 3 T brain MRI including DTI. After clinical follow-up (mean 28.3 months), diagnoses could be made in 49 patients (30 PD and 19 AP). Conventional brain MRI was evaluated for regions of atrophy and signal intensity changes. Tract-based spatial statistics and ROI analyses of DTI were performed to analyze group differences in mean diffusivity (MD) and fractional anisotropy (FA), and diagnostic thresholds were determined. Diagnostic accuracy of conventional brain MRI and DTI was assessed with the receiver operating characteristic (ROC). Significantly higher MD of the centrum semiovale, body corpus callosum, putamen, external capsule, midbrain, superior cerebellum, and superior cerebellar peduncles was found in AP. Significantly increased MD of the putamen was found in multiple system atrophy-parkinsonian form (MSA-P) and increased MD in the midbrain and superior cerebellar peduncles in progressive supranuclear palsy (PSP). The diagnostic accuracy of brain MRI to identify AP as a group was not improved by ROI measures of MD, though the diagnostic accuracy to identify MSA-P was slightly increased (AUC 0.82 to 0.85). The diagnostic accuracy of brain MRI to identify AP as a group was not improved by the current analysis approach to DTI, though DTI measures could be of added value to identify AP subgroups. (orig.)

  6. Conventional 3T brain MRI and diffusion tensor imaging in the diagnostic workup of early stage parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Meijer, Frederick J.A. [Radboud University Nijmegen Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Rumund, Anouke van; Tuladhar, Anil M.; Aerts, Marjolein B.; Titulaer, Imke; Esselink, Rianne A.J.; Bloem, Bastiaan R. [Radboud University Nijmegen Medical Center, Department of Neurology, Donders Institute for Brain, Cognition and Behaviour, Nijmegen (Netherlands); Verbeek, Marcel M. [Radboud University Nijmegen Medical Center, Department of Neurology, Donders Institute for Brain, Cognition and Behaviour, Nijmegen (Netherlands); Radboud University Nijmegen Medical Center, Department of Laboratory Medicine, Nijmegen (Netherlands); Goraj, Bozena [Radboud University Nijmegen Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Medical Center of Postgraduate Education, Department of Diagnostic Imaging, Warsaw (Poland)

    2015-07-15

    The aim of this study is to evaluate whether the diagnostic accuracy of 3 T brain MRI is improved by region of interest (ROI) measures of diffusion tensor imaging (DTI), to differentiate between neurodegenerative atypical parkinsonism (AP) and Parkinson's disease (PD) in early stage parkinsonism. We performed a prospective observational cohort study of 60 patients presenting with early stage parkinsonism and initial uncertain diagnosis. At baseline, patients underwent a 3 T brain MRI including DTI. After clinical follow-up (mean 28.3 months), diagnoses could be made in 49 patients (30 PD and 19 AP). Conventional brain MRI was evaluated for regions of atrophy and signal intensity changes. Tract-based spatial statistics and ROI analyses of DTI were performed to analyze group differences in mean diffusivity (MD) and fractional anisotropy (FA), and diagnostic thresholds were determined. Diagnostic accuracy of conventional brain MRI and DTI was assessed with the receiver operating characteristic (ROC). Significantly higher MD of the centrum semiovale, body corpus callosum, putamen, external capsule, midbrain, superior cerebellum, and superior cerebellar peduncles was found in AP. Significantly increased MD of the putamen was found in multiple system atrophy-parkinsonian form (MSA-P) and increased MD in the midbrain and superior cerebellar peduncles in progressive supranuclear palsy (PSP). The diagnostic accuracy of brain MRI to identify AP as a group was not improved by ROI measures of MD, though the diagnostic accuracy to identify MSA-P was slightly increased (AUC 0.82 to 0.85). The diagnostic accuracy of brain MRI to identify AP as a group was not improved by the current analysis approach to DTI, though DTI measures could be of added value to identify AP subgroups. (orig.)

  7. [Evaluation of general practitioners' knowledge about diagnostic and therapeuthic management of erysipelas in the city of Marrakech].

    Science.gov (United States)

    Ihbibane, Fatima; Arsène, Ntini Lebi; Adarmouch, Latifa; Amine, Mohamed; Tassi, Noura

    2018-01-01

    Erysipelas is the most common non necrotizing bacterial dermohypodermitis (NNBDH). This study aimed to evaluate the adequacy of general practitioners' knowledge about literature data on the diagnostic and therapeuthic management of erysipelas. We conducted a cross-sectional descriptive and analytical survey of 167 general practitioners in the public and private sectors in Marrakech over the period from 19 May to 20 October 2014. The 114 questionnaires which had been returned revealed that local and general risk factors were often reported for erysipelas. 92 (80.7%) physicians thought that positive diagnosis of common types was based on clinical examination. 97(85.1%) physicians thought that it required only out-patient service and that hospitalization and para-clinical examinations should only be performed in patients with severe, atypical or complicated erysipelas. 25 (21.9%) physicians thought that oral amoxicillin should be the gold standard therapy. 15(13.2%) physicians thought that bi-antibiotic therapy including antistreptococcique molecule should be the gold standard. 16 doctors (14%) advocated anti-inflammatory drugs. The primary and secondary prevention levels generated interest from physicians of whom 108 (94.7%) were favorable to the treatment of the portals of entry in the skin while 53 (46.5%) to the antibioprophylaxis after the second recurrence. Our study highlights that erysipelas is relatively frequent in city medical practice; clinical diagnosis guidelines should be shared between the specialists in order to improve the diagnostic and therapeutic approch of our physicians.

  8. Evaluation of diagnostic methods for the detection of Helicobacter pylori in gastric biopsy specimens of dyspeptic patients

    Directory of Open Access Journals (Sweden)

    Ivy Bastos Ramis

    2012-09-01

    Full Text Available Helicobacter pylori infects nearly 50% of the world's population. This microorganism is accepted as the most important agent of gastritis and as a risk factor for peptic ulcer disease and gastric adenocarcinoma. Currently many diagnostic methods exist for detecting H. pylori, however they all have limitations, thus it is recommend a combination of at least two methods. The aim of this study was to evaluate diagnostic methods, such as in-house urease test, culture and Polymerase Chain Reaction (PCR, for the detection of the H. pylori in gastric biopsy specimens of 144 dyspeptic patients, using as gold standard the association between histology and rapid urease test. According to the gold standard used in this study, 48 (33.3% patients were infected with H. pylori, while 96 (66.7% were classified as not infected. The in-house urease test and the PCR were the most sensitive methods (100%, followed by culture (85.4%. However, the in-house urease test and the culture were the most specific (100%, followed by PCR (75%. In conclusion, this study showed that, in comparison with the combination of histology and rapid urease test, the in-house urease test and the PCR presented 100% of sensitivity in the diagnosis of gastric infection by H. pylori, while the in-house urease test and the culture reached 100% of specificity. These finding suggest that the combination of two or more methods may improve the accuracy of the H. pylori detection.

  9. Evaluation of doses given to foetus in diagnostic radiology in Israel

    International Nuclear Information System (INIS)

    Schlesinger, T.; Donagi, A.; Karpinovitz, A.

    1975-01-01

    Among the various groups exposed to diagnostic radiation, pregnant women, during the first months of pregnancy, require special attention, because of the high sensitivity of the developing foetus to ionizing radiation. In light of this sensitivity, special limitations were adopted in different countries, concerning female X-ray technicians in the reproductive age. However, it frequently happens that a pregnant woman is irradiated during the first months of pregnancy, due to the fact that neither she nor the attending physician is aware that she is pregnant. Many times, after this fact is realized, physicists are asked to ''reconstruct'' the radiographs in order to evaluate the foetus dose. The purpose of this ''reconstruction'' is to determine whether an abortion is to be performed. The present work constitutes the first stage of a research desianed to provide the radiologist with typical Israeli data, which he could use for evaluating the order of magnitude of the foetus dose. The purpose of this ''preliminary evaluation'' carried out by the radiologist is to determine whether the foetus dose is of such a magnitude justifying the performance of a specific ''reconstruction test'' or not. (B.G.)

  10. Economic evaluation of diagnostic localization following biochemical prostate cancer recurrence.

    Science.gov (United States)

    Barocas, Daniel A; Bensink, Mark E; Berry, Kristin; Musa, Zahra; Bodnar, Carolyn; Dann, Robert; Ramsey, Scott D

    2014-10-01

    The aim of this study was to assess potential cost-effectiveness of using a prostate cancer specific functional imaging technology capable of identifying residual localized disease versus small volume metastatic disease for asymptomatic men with low but detectable prostate specific antigen (PSA) elevation following radical prostatectomy. Markov modeling was used to estimate the incremental impact on healthcare system costs (2012 USD) and quality-adjusted life-years (QALYs) of two alternative strategies: (i) using the new diagnostic to guide therapy versus (ii) current usual care-using a combination of computed tomography, magnetic resonance imaging, and bone scan to guide therapy. Costs were based on estimates from literature and Medicare reimbursement. Prostate cancer progression, survival, utilities, and background risk of all-cause mortality were obtained from literature. Base-case diagnostic sensitivity (75 percent), specificity (90 percent), and cost (USD 2,500) were provided by our industry partner GE Healthcare. The new diagnostic strategy provided an average gain of 1.83 (95 percent uncertainty interval [UI]: 1.24-2.64) QALYs with added costs of USD 15,595 (95 percent UI: USD -6,330-44,402) over 35 years. The resulting incremental cost-effectiveness ratio was USD 8,516/QALY (95 percent UI: USD -2,947-22,372). RESULTS were most influenced by the utility discounting rate and test performance characteristics; however, the new diagnostic provided clinical benefits over a wide range of sensitivity and specificity. This analysis suggests a diagnostic technology capable of identifying whether men with biochemical recurrence after radical prostatectomy have localized versus metastatic disease would be a cost-effective alternative to current standard work-up. The results support additional investment in development and validation of such a diagnostic.

  11. Proposed diagnostic criteria for internet addiction.

    Science.gov (United States)

    Tao, Ran; Huang, Xiuqin; Wang, Jinan; Zhang, Huimin; Zhang, Ying; Li, Mengchen

    2010-03-01

    The objective of this study was to develop diagnostic criteria for internet addiction disorder (IAD) and to evaluate the validity of our proposed diagnostic criteria for discriminating non-dependent from dependent internet use in the general population. This study was conducted in three stages: the developmental stage (110 subjects in the survey group; 408 subjects in the training group), where items of the proposed diagnostic criteria were developed and tested; the validation stage (n = 405), where the proposed criteria were evaluated for criterion-related validity; and the clinical stage (n = 150), where the criteria and the global clinical impression of IAD were evaluated by more than one psychiatrist to determine inter-rater reliability. The proposed internet addiction diagnostic criteria consisted of symptom criterion (seven clinical symptoms of IAD), clinically significant impairment criterion (functional and psychosocial impairments), course criterion (duration of addiction lasting at least 3 months, with at least 6 hours of non-essential internet usage per day) and exclusion criterion (exclusion of dependency attributed to psychotic disorders). A diagnostic score of 2 + 1, where the first two symptoms (preoccupation and withdrawal symptoms) and at least one of the five other symptoms (tolerance, lack of control, continued excessive use despite knowledge of negative effects/affects, loss of interests excluding internet, and use of the internet to escape or relieve a dysphoric mood) was established. Inter-rater reliability was 98%. Our findings suggest that the proposed diagnostic criteria may be useful for the standardization of diagnostic criteria for IAD.

  12. Colonoscopy: Evaluating indications and diagnostic yield

    International Nuclear Information System (INIS)

    Al-Shamali, Mohammed A.; Hasan, F.; Siddiqe, I.; Al-Nakeeb, B.; Kalaoui, M.; Khajah, A.

    2001-01-01

    Colonoscopic procedure is an accepted modality for the evaluation ofcolonic disease. Open-access versus restricted-access colonoscopy has beenargued over in the recent literature. The aim of this retrospective analysisis to identify the yield of the major indications for the procedure, and thepattern of colon pathology in our community. We retrospectively analyzed ourexperience in 3000 colonoscopies over a five-year period. The patientscomprised 1145 females (38%) and 1855 males (62%) and their ages ranged from9 months to 95 years (mean 39.2). There were 2283 patients (76%) who wereaged less than 55 years. Complete examination to the cecum was possible in2850 cases (95%). Pathological findings were identified in 640 patients(21%). The diagnostic yield of patients referred for lower abdominal pain andsurveillance was low, at 7% and 17%, respectively. The yield was high forthose with lower gastrointestinal bleeding (47%), non-bloody diarrhea (35%),iron deficiency anemia (30%), mass lesions identified by radiology (53%) andpolyps identified by radiology (70%). Inflammatory bowel disease wasdiagnosed in 220 patients, carcinoma in 64 patients and colonic polyps in 139patients. Colonic diseases are not uncommon in our part of the world.Colonoscopy is a rewarding procedure in those patients referred with lowergastrointestinal bleeding, mass lesions, polyps and diarrhea. The procedureis less rewarding in patients with lower abdominal pain and in thoseundergoing surveillance colonoscopy. Patient selection on the basis of thepresenting complaint may help to utilize the limited resource available togastroenterologists. About 63% of the procedures were done for indicationsfound to have a low yield. Inflammatory bowel disease is seen with increasingfrequency in our population. (author)

  13. A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); De Cecco, Carlo N.; Yamada, Ricardo T.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Fuller, Stephen R. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Vogl, Thomas J.; Wichmann, Julian L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Todoran, Thomas M. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2016-12-15

    To evaluate the impact of noise-optimized virtual monochromatic imaging (VMI+) on stent visualization and accuracy for in-stent re-stenosis at lower extremity dual-energy CT angiography (DE-CTA). We evaluated third-generation dual-source DE-CTA studies in 31 patients with prior stent placement. Images were reconstructed with linear blending (F{sub 0}.5) and VMI+ at 40-150 keV. In-stent luminal diameter was measured and contrast-to-noise ratio (CNR) calculated. Diagnostic confidence was determined using a five-point scale. In 21 patients with invasive catheter angiography, accuracy for significant re-stenosis (≥50 %) was assessed at F{sub 0}.5 and 80 keV-VMI+ chosen as the optimal energy level based on image-quality analysis. At CTA, 45 stents were present. DSA was available for 28 stents whereas 12 stents showed significant re-stenosis. CNR was significantly higher with ≤80 keV-VMI+ (17.9 ± 6.4-33.7 ± 12.3) compared to F{sub 0}.5 (16.9 ± 4.8; all p < 0.0463); luminal stent diameters were increased at ≥70 keV (5.41 ± 1.8-5.92 ± 1.7 vs. 5.27 ± 1.8, all p < 0.001) and diagnostic confidence was highest at 70-80 keV-VMI+ (4.90 ± 0.48-4.88 ± 0.63 vs. 4.60 ± 0.66, p = 0.001, 0.0042). Sensitivity, negative predictive value and accuracy for re-stenosis were higher with 80 keV-VMI+ (100, 100, 96.4 %) than F{sub 0}.5 (90.9, 94.1, 89.3 %). 80 keV-VMI+ improves image quality, diagnostic confidence and accuracy for stent evaluation at lower extremity DE-CTA. (orig.)

  14. Molecular diagnostics of periodontitis

    OpenAIRE

    Izabela Korona-Głowniak; Radosław Siwiec; Marcin Berger; Anna Malm; Jolanta Szymańska

    2017-01-01

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridi...

  15. Diagnostic evaluation of rhabdomyolysis.

    Science.gov (United States)

    Nance, Jessica R; Mammen, Andrew L

    2015-06-01

    Rhabdomyolysis is characterized by severe acute muscle injury resulting in muscle pain, weakness, and/or swelling with release of myofiber contents into the bloodstream. Symptoms develop over hours to days after an inciting factor and may be associated with dark pigmentation of the urine. Serum creatine kinase and urine myoglobin levels are markedly elevated. Clinical examination, history, laboratory studies, muscle biopsy, and genetic testing are useful tools for diagnosis of rhabdomyolysis, and they can help differentiate acquired from inherited causes of rhabdomyolysis. Acquired causes include substance abuse, medication or toxic exposures, electrolyte abnormalities, endocrine disturbances, and autoimmune myopathies. Inherited predisposition to rhabdomyolysis can occur with disorders of glycogen metabolism, fatty acid β-oxidation, and mitochondrial oxidative phosphorylation. Less common inherited causes of rhabdomyolysis include structural myopathies, channelopathies, and sickle-cell disease. This review focuses on the differentiation of acquired and inherited causes of rhabdomyolysis and proposes a practical diagnostic algorithm. Muscle Nerve 51: 793-810, 2015. © 2015 Wiley Periodicals, Inc.

  16. Correcting biases in psychiatric diagnostic practice in Northwest Russia: Comparing the impact of a general educational program and a specific diagnostic training program

    Directory of Open Access Journals (Sweden)

    Rezvyy Grigory

    2008-04-01

    Full Text Available Abstract Background A general education in psychiatry does not necessary lead to good diagnostic skills. Specific training programs in diagnostic coding are established to facilitate implementation of ICD-10 coding practices. However, studies comparing the impact of these two different educational approaches on diagnostic skills are lacking. The aim of the current study was to find out if a specific training program in diagnostic coding improves the diagnostic skills better than a general education program, and if a national bias in diagnostic patterns can be minimised by a specific training in diagnostic coding. Methods A pre post design study with two groups was carried in the county of Archangels, Russia. The control group (39 psychiatrists took the required course (general educational program, while the intervention group (45 psychiatrists were given a specific training in diagnostic coding. Their diagnostic skills before and after education were assessed using 12 written case-vignettes selected from the entire spectrum of psychiatric disorders. Results There was a significant improvement in diagnostic skills in both the intervention group and the control group. However, the intervention group improved significantly more than did the control group. The national bias was partly corrected in the intervention group but not to the same degree in the control group. When analyzing both groups together, among the background factors only the current working place impacted the outcome of the intervention. Conclusion Establishing an internationally accepted diagnosis seems to be a special skill that requires specific training and needs to be an explicit part of the professional educational activities of psychiatrists. It does not appear that that skill is honed without specific training. The issue of national diagnostic biases should be taken into account in comparative cross-cultural studies of almost any character. The mechanisms of such biases are

  17. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  18. Cognitive aspect of diagnostic errors.

    Science.gov (United States)

    Phua, Dong Haur; Tan, Nigel C K

    2013-01-01

    Diagnostic errors can result in tangible harm to patients. Despite our advances in medicine, the mental processes required to make a diagnosis exhibits shortcomings, causing diagnostic errors. Cognitive factors are found to be an important cause of diagnostic errors. With new understanding from psychology and social sciences, clinical medicine is now beginning to appreciate that our clinical reasoning can take the form of analytical reasoning or heuristics. Different factors like cognitive biases and affective influences can also impel unwary clinicians to make diagnostic errors. Various strategies have been proposed to reduce the effect of cognitive biases and affective influences when clinicians make diagnoses; however evidence for the efficacy of these methods is still sparse. This paper aims to introduce the reader to the cognitive aspect of diagnostic errors, in the hope that clinicians can use this knowledge to improve diagnostic accuracy and patient outcomes.

  19. Diagnostic evaluation of the MRP-8/14 for the emergency assessment of chest pain.

    Science.gov (United States)

    Vora, Amit N; Bonaca, Marc P; Ruff, Christian T; Jarolim, Petr; Murphy, Sabina; Croce, Kevin; Sabatine, Marc S; Simon, Daniel I; Morrow, David A

    2012-08-01

    Elevated levels of myeloid-related protein (MRP)-8/14 (S100A8/A9) are associated with first cardiovascular events in healthy individuals and worse prognosis in patients with acute coronary syndrome (ACS). The diagnostic utility of MRP-8/14 in patients presenting to the emergency room with symptoms concerning for ACS is uncertain. MRP-8/14 was measured in serial serum and plasma samples in a single center prospective cohort-study of patients presenting to the emergency room with non-traumatic chest pain concerning for ACS. Final diagnosis was adjudicated by an endpoint committee. Of patients with baseline MRP-8/14 results (n = 411), the median concentration in serum was 1.57 μg/ml (25th, 75th: 0.87, 2.68) and in plasma was 0.41 μg/ml (MRP-8/14 was higher in patients presenting with MI (p MRP-8/14 was poor: sensitivity 28% (95% CI 20-38), specificity 82% (78-86), positive predictive value 36% (26-47), and negative predictive value 77% (72-81). The area under the ROC curve for diagnosis of MI with MRP-8/14 was 0.55 (95% CI 0.51-0.60) compared with 0.95 for cTnI. The diagnostic performance was not improved in early-presenters, patients with negative initial cTnI, or using later MRP-8/14 samples. Patients presenting with MI had elevated levels of serum MRP-8/14 compared to patients with non-cardiac chest pain. However, overall diagnostic performance of MRP-8/14 was poor and neither plasma nor serum MRP-8/14 offered diagnostic utility comparable to cardiac troponin.

  20. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  1. Does supplier evaluation impact process improvement?

    Directory of Open Access Journals (Sweden)

    Shiva Prasad h c

    2016-09-01

    Full Text Available Purpose: The research explores and examines factors for supplier evaluation and its impact on process improvement particularly aiming on a steel pipe manufacturing firm in Gujarat, India. Design/Methodology/approach: The conceptual research framework was developed and hypotheses were stated considering the analysis of literature and discussions with the managers and engineers of a steel pipe manufacturing company in Gujarat, India. Data was collected using in-depth interview. The questionnaire primarily involves the perception of evaluation of supplier. Factors influencing supplier evaluation and its influence on process improvement is also examined in this study. The model testing and validation was done using partial least square method. Outcomes signified that the factors that influence evaluation of the supplier are quality, cost, delivery and supplier relationship management. Findings: The study depicted that quality and cost factors for supplier evaluation are insignificant. The delivery and supplier relationship management have significant influence on evaluation of the supplier. The research also depicted that supplier evaluation has significant influence on process improvement. Research limitations/implications: The study has been made specifically for ABC steel pipe manufacturing industry in Gujarat, India and may not be appropriate to the other industries or any parts of the world. There is a possibility of response bias as the conclusions of this research was interpreted on survey responses taken from the employees of case study company, so it is suggested that future research can overcome this problem by employing various methodologies in addition to surveys like carrying out focus group and in-depth interviews, brainstorming sessions with the experts etc. Originality/value: Many researchers have considered quality, cost and delivery as the factors for evaluating the suppliers. But for a company it is quintessential to have good

  2. The diagnostic value of plasma N-terminal connective tissue growth factor levels in children with heart failure.

    Science.gov (United States)

    Li, Gang; Song, Xueqing; Xia, Jiyi; Li, Jing; Jia, Peng; Chen, Pengyuan; Zhao, Jian; Liu, Bin

    2017-01-01

    The aim of this study was to assess the diagnostic value of plasma N-terminal connective tissue growth factor in children with heart failure. Methods and results Plasma N-terminal connective tissue growth factor was determined in 61 children, including 41 children with heart failure, 20 children without heart failure, and 30 healthy volunteers. The correlations between plasma N-terminal connective tissue growth factor levels and clinical parameters were investigated. Moreover, the diagnostic value of N-terminal connective tissue growth factor levels was evaluated. Compared with healthy volunteers and children without heart failure, plasma N-terminal connective tissue growth factor levels were significantly elevated in those with heart failure (p0.05), but it obviously improved the ability of diagnosing heart failure in children, as demonstrated by the integrated discrimination improvement (6.2%, p=0.013) and net re-classification improvement (13.2%, p=0.017) indices. Plasma N-terminal connective tissue growth factor is a promising diagnostic biomarker for heart failure in children.

  3. Clinical diagnostic potentials of thyroid ultrasonography and scintigraphy; An evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Torizuka, Tatsuo; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Konishi, Junji (Kyoto Univ. (Japan). Hospital); Endo, Keigo

    1993-06-01

    This prospective study was designed to evaluate the potential contributions of high resolution ultrasonography (US) and Tc-99m scintigraphy in the routine diagnosis of thyroid disease. The diagnostic impacts of US and Tc-99m scintigraphy results in 177 patients visiting our thyroid clinic were assessed and scored according to the following criteria: when the information provided by either test supported, confirmed or changed the initial clinical diagnosis, they received scores of 2, 3 and 4 respectively, while score 1 was given when the test itself was useless for the differential diagnosis. US identified focal lesions that both palpation and scintigraphy had failed to detect in 14 (12.1%) of 116 patients with diffuse thyroid diseases, suggesting the necessity of Hashimoto's thyroiditis, adenoma, adenocarcinoma and adenomatous goiter, and vice versa in the diagnosis of hyperthyroid and euthyroid Graves's diseases. Thus, the advantages of US over scintigraphy for morphological evaluation were confirmed. US was particularly useful for the differential diagnosis of adenomatous goiter from Hashimoto's thyroiditis or a single nodular disease. In contrast, scintigraphy gave functional images, being especially helpful for the differential diagnosis of thyrotoxicosis. (author).

  4. Improved patient specific seizure detection during pre-surgical evaluation.

    LENUS (Irish Health Repository)

    Chua, Eric C-P

    2011-04-01

    There is considerable interest in improved off-line automated seizure detection methods that will decrease the workload of EEG monitoring units. Subject-specific approaches have been demonstrated to perform better than subject-independent ones. However, for pre-surgical diagnostics, the traditional method of obtaining a priori data to train subject-specific classifiers is not practical. We present an alternative method that works by adapting the threshold of a subject-independent to a specific subject based on feedback from the user.

  5. Diagnostic value and timing of serum antichlamidial antibody level evaluation during infertility workup among infertile women in whom tubal factor was detected with diagnostic laparoscopy

    Directory of Open Access Journals (Sweden)

    Serkan Kahyaoğlu

    2012-03-01

    Full Text Available OBJECTIVES: With normal hysterosalpingography (HSG results, selecting suitable candidates for the laparoscopic treatment of probable pelvic adhesions following previous pelvic inflammatory disease, it would be wise to investigate serum antibody screening against chlamidia trachomatis. It is worth to evaluate whether it is useful to detect a negative antichlamidial antibody disease for cancelling laparoscopy for a while with abnormal HSG findings. These two subjects have been investigated in study. MATERIAL AND METHODS: For detecting diagnostic value of serum antichlamidial antibody, in our infertility clinic, postoperative blood samples of 80 patients who were hospitalized for diagnostic laparoscopy to investigate infertility ethiology between May 2004 and November 2005 have been tested with microelisa method for antichlamidial IgM and IgG antibodies. HSG films of the patients performed at least one year were evaluated. Venous blood was drawn from these patients during postoperative early period for studying serum IgM and IgG antibodies of chlamidia trachomatis and the results were compared with operative findings. RESULTS: According to the antichlamidial antibody levels 60 (75% patients have not been infected with chlamidia and 20 (25% patients have been infected previously. When the patients were divided to two groups; normal and abnormal; based on preoperative HSG films; 18 (30% of the 60 patients with abnormal HSG films and 2 (10% of the 20 patients with normal HSG films had positive antichlamidial antibody levels respectively. CONCLUSION: The relationship between chlamidia trachomatis infection and tubal infertility has been demonstrated among 85% of patients with positive antichlamidial antibody levels and 46.7% of patients with negative levels who had tubal passage defects detected during diagnostic laparoscopy.

  6. Microfluidic technology for molecular diagnostics.

    Science.gov (United States)

    Robinson, Tom; Dittrich, Petra S

    2013-01-01

    Molecular diagnostics have helped to improve the lives of millions of patients worldwide by allowing clinicians to diagnose patients earlier as well as providing better ongoing therapies. Point-of-care (POC) testing can bring these laboratory-based techniques to the patient in a home setting or to remote settings in the developing world. However, despite substantial progress in the field, there still remain many challenges. Progress in molecular diagnostics has benefitted greatly from microfluidic technology. This chapter aims to summarise the more recent advances in microfluidic-based molecular diagnostics. Sections include an introduction to microfluidic technology, the challenges of molecular diagnostics, how microfluidic advances are working to solve these issues, some alternative design approaches, and detection within these systems.

  7. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    Science.gov (United States)

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Resource utilization and costs associated with the diagnostic evaluation of nonrefluxing primary hydronephrosis in infants.

    Science.gov (United States)

    Akhavan, Ardavan; Shnorhavorian, Margarett; Garrison, Louis P; Merguerian, Paul A

    2014-09-01

    Long-term evaluation of postnatal nonrefluxing primary hydronephrosis presents a dilemma for urologists since most cases resolve without surgery. We report longitudinal resource utilization and costs associated with diagnostic evaluation of infants with isolated primary nonrefluxing hydronephrosis to determine the costs associated with diagnosing a surgical case, and we assess the implications using a cost-consequences analysis. A retrospective chart review was used to capture resource utilization for all patients younger than 6 months with hydronephrosis evaluated at our institution during a 5-year period. Infants with confounding urological diagnoses were excluded. Payer and societal perspectives were used. Costs were estimated from resource utilization, including radiographic imaging and clinical encounter types. Data were collected from first clinic visit until surgery or resolution or 3 years, whichever was shortest. Of 165 included patients surgical rates for hydronephrosis were 0% for grade I, 5% for grade II, 21% for grade III and 74% for grade IV. Median respective costs of identifying a single surgical case per increasing hydronephrosis grade 0 to IV were infinite, $37,600, $11,741 and $2,124 (p hydronephrosis is significantly more productive in terms of identifying patients requiring surgery vs evaluation of patients with lower grade disease. In patients with grades I and II hydronephrosis a more abbreviated diagnostic strategy than the current standard of care may be warranted. For the population in this analysis we project that a less intensive approach could save about 24% of costs. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Assessing Old and New Diagnostic Tests for Gastroesophageal Reflux Disease.

    Science.gov (United States)

    Vaezi, Michael F; Sifrim, Daniel

    2018-01-01

    A detailed critique of objective measurements of gastroesophageal reflux disease (GERD) would improve management of patients suspecting of having reflux, leading to rational selection of treatment and better outcomes. Many diagnostic tests for GERD have been developed over the past decades. We analyze their development, positive- and negative-predictive values, and ability to predict response to treatment. These features are important for development of medical, surgical, and endoscopic therapies for GERD. We discuss the value of available diagnostic tests and review their role in management of patients with persistent reflux symptoms despite adequate medical or surgical treatment. This is becoming a significant health economic problem, due to the widespread use of proton pump inhibitors. GERD is believed to cause nonesophageal symptoms, such as those provoked by ear, nose, throat, or respiratory disorders. We analyze the value of GERD diagnostic tests in evaluation of these troublesome, nonesophageal symptoms. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Cognitive and system factors contributing to diagnostic errors in radiology.

    Science.gov (United States)

    Lee, Cindy S; Nagy, Paul G; Weaver, Sallie J; Newman-Toker, David E

    2013-09-01

    In this article, we describe some of the cognitive and system-based sources of detection and interpretation errors in diagnostic radiology and discuss potential approaches to help reduce misdiagnoses. Every radiologist worries about missing a diagnosis or giving a false-positive reading. The retrospective error rate among radiologic examinations is approximately 30%, with real-time errors in daily radiology practice averaging 3-5%. Nearly 75% of all medical malpractice claims against radiologists are related to diagnostic errors. As medical reimbursement trends downward, radiologists attempt to compensate by undertaking additional responsibilities to increase productivity. The increased workload, rising quality expectations, cognitive biases, and poor system factors all contribute to diagnostic errors in radiology. Diagnostic errors are underrecognized and underappreciated in radiology practice. This is due to the inability to obtain reliable national estimates of the impact, the difficulty in evaluating effectiveness of potential interventions, and the poor response to systemwide solutions. Most of our clinical work is executed through type 1 processes to minimize cost, anxiety, and delay; however, type 1 processes are also vulnerable to errors. Instead of trying to completely eliminate cognitive shortcuts that serve us well most of the time, becoming aware of common biases and using metacognitive strategies to mitigate the effects have the potential to create sustainable improvement in diagnostic errors.

  11. Improved Temperature Diagnostic for Non-Neutral Plasmas with Single-Electron Resolution

    Science.gov (United States)

    Shanman, Sabrina; Evans, Lenny; Fajans, Joel; Hunter, Eric; Nelson, Cheyenne; Sierra, Carlos; Wurtele, Jonathan

    2016-10-01

    Plasma temperature diagnostics in a Penning-Malmberg trap are essential for reliably obtaining cold, non-neutral plasmas. We have developed a setup for detecting the initial electrons that escape from a trapped pure electron plasma as the confining electrode potential is slowly reduced. The setup minimizes external noise by using a silicon photomultiplier to capture light emitted from an MCP-amplified phosphor screen. To take advantage of this enhanced resolution, we have developed a new plasma temperature diagnostic analysis procedure which takes discrete electron arrival times as input. We have run extensive simulations comparing this new discrete algorithm to our existing exponential fitting algorithm. These simulations are used to explore the behavior of these two temperature diagnostic procedures at low N and at high electronic noise. This work was supported by the DOE DE-FG02-06ER54904, and the NSF 1500538-PHY.

  12. Evaluating and Improving Online Intelligence Courses

    Directory of Open Access Journals (Sweden)

    Dr. Alexandra Luce

    2013-08-01

    Full Text Available Civilian, military and government institutions offer a wide range of courses on intelligence and are increasingly doing so online. While evaluation and improvement are critical to ensuring quality training and education, there is little research about how to evaluate and improve online intelligence courses. Based on the author’s experience developing and teaching such courses, this article offers four suggestions to those involved in online intelligence training and education: (1 conduct a key assumptions check; (2 ensure the course presentation embodies the principles of intelligence communication; (3 encourage creative freedom; and (4 build in mechanisms for feedback throughout the course.

  13. Towards a Diagnostic Instrument to Identify Improvement Opportunities for Quality Controlled Logistics in Agrifood Supply Chain Networks

    Directory of Open Access Journals (Sweden)

    Jack G.A.J. van der Vorst

    2011-10-01

    Full Text Available  Western-European consumers have become not only more demanding on product availability in retail outlets but also on other food attributes such as quality, integrity, and safety. When (redesigning food supply-chain networks, from a logistics point of view, one has to consider these demands next to traditional efficiency and responsiveness requirements. The concept ‘quality controlled logistics’ (QCL hypothesizes that if product quality in each step of the supply chain can be predicted in advance, goods flows can be controlled in a pro-active manner and better chain designs can be established resulting in higher product availability, constant quality, and less product losses. The paper discusses opportunities of using real-time product quality information for improvement of the design and management of ‘AgriFood Supply Chain Networks’, and presents a preliminary diagnostic instrument for assessment of ‘critical quality’ and ‘logistics control’ points in the supply chain network. Results of a tomato-chain case illustrate the added value of the QCL concept for identifying improvement opportunities in the supply chain as to increase both product availability and quality. Future research aims for the further development of the diagnostic instrument and the quantification of costs and benefits of QCL scenarios.

  14. [Evaluation of the toxoplasmosis seroprevalence in pregnant women and creating a diagnostic algorithm].

    Science.gov (United States)

    Mumcuoglu, Ipek; Toyran, Alparslan; Cetin, Feyza; Coskun, Feride Alaca; Baran, Irmak; Aksu, Neriman; Aksoy, Altan

    2014-04-01

    Toxoplasma gondii, an obligatory intracellular protozoon is widely distributed around the world and can infect all mammals and birds. While acquired toxoplasmosis is usually asymptomatic in healthy subjects, acute infection during pregnancy may lead to abortion, stillbirth, fetal neurological and ocular damages. For the prevention of congenital toxoplasmosis it is recommended that a screening programme and a diagnostic algorithm in pregnant women should be implemented while considering the cost effectiveness. Thus, it is necessary to determine the seroprevalence of toxoplasmosis in pregnant women and the actual risk of T.gondii transmission during pregnancy in a certain area. The aims of this study were to detect the T.gondii seropositivity in the pregnant women admitted to our hospital and to create a diagnostic algorithm in order to solve the problems arising from interpretation of the serological test results. A total of 6140 women aged 15-49 years who were admitted to our hospital between April 1st, 2010 to July 31st, 2013, were evaluated retrospectively. In the serum samples, T.gondii IgM, IgG and IgG avidity tests were performed by VIDAS automated analyzer using TOXO IgM, TOXO IgG II and TOXO IgG avidity kits (bioMerieux, France). It was noted that, both T.gondii IgM and IgG tests were requested from 4758 (77.5%) of the pregnant women, while only IgM test from 1382 (22.5%) cases. Sole IgM positivity was found as 0.2% (11/6140), IgG as 26.4% (1278/4758) and both IgM + IgG as 0.9% (44/4758). T.gondii IgG avidity tests were requested from 12 of 44 women who were found both IgM and IgG positive and eight of them revealed high avidity and four low avidity. Avidity test was ordered for the 91 (7.1%) of 1278 sole IgG positive cases and four of them were found to have low avidity. IgG avidity test was ordered for 554 (16.2%) of IgM and/or IgG negative subjects, however, the test was not performed according to rejection criteria of the laboratory. It was noticed that

  15. Severe oligohydramnios with intact membranes: an indication for diagnostic amnioinfusion.

    Science.gov (United States)

    Pryde, P G; Hallak, M; Lauria, M R; Littman, L; Bottoms, S F; Johnson, M P; Evans, M I

    2000-01-01

    To quantify the improvement in ultrasonographic fetal imaging following diagnostic amnioinfusion for the indication of unexplained midtrimester oligohydramnios. Patients referred for unexplained midtrimester oligohydramnios were retrospectively reviewed. Videotapes of those undergoing diagnostic antenatal amnioinfusion were analyzed for quality of visualization of routinely imaged structures before and after the infusion procedure. The overall rate of adequate visualization of fetal structures improved from 50.98 to 76.79% (p amnioinfusion can facilitate fetal imaging and increase diagnostic precision in the setting of unexplained severe oligohydramnios. We have quantified the improvement in the rate of optimal visualization of fetal structures which likely translates, in experienced hands, into this observed improved diagnostic precision. Of particular importance is the improvement in appreciation of associated anomalies in cases of obstructive uropathy in which such findings may determine whether or not invasive fetal therapy is indicated. Copyright 2000 S. Karger AG, Basel.

  16. Aircraft gas turbine engine vibration diagnostics

    OpenAIRE

    Stanislav Fábry; Marek Češkovič

    2017-01-01

    In the Czech and Slovak aviation are in service elderly aircrafts, usually produced in former Soviet Union. Their power units can be operated in more efficient way, in case of using additional diagnostic methods that allow evaluating their health. Vibration diagnostics is one of the methods indicating changes of rotational machine dynamics. Ground tests of aircraft gas turbine engines allow vibration recording and analysis. Results contribute to airworthiness evaluation and making corrections...

  17. The diagnostic value of double-contrast-technique cystography in the evaluation of benign and malignant lesions of the urinary bladder

    International Nuclear Information System (INIS)

    Beyer, D.; Koester, R.; Schuett, H.

    1979-01-01

    Cystography by double-contrast-technique as simple and quick method of evaluating benign and malignant lesions of the urinary bladder is being described. 301 examinations were reviewed and are being discussed in regard to diagnostic value, indication, complication and radiation exposure of this method. A few typical cases are being demonstrated to illustrate the value of this method in the spectrum of other diagnostic methods in the workup of urinary bladder lesions. (orig.) [de

  18. [Methods for evaluating diagnostic tests in Enfermedades Infecciosas y Microbiología Clínica].

    Science.gov (United States)

    Ramos, J M; Hernández, I

    1998-04-01

    In the field of infectious diseases and clinical microbiology, the evaluation of diagnostic tests (DT) is an important research area. The specific difficulties of this type of research has motivated that have not caught the severity methodological of others areas of clinical research. This article try to asses and characterize the methodology of articles about DT published in Enfermedades Infecciosas y Microbiología Clínica (EIMC) journal. Forty-five articles was selected in the EIMC journal during the 1990-1996 period, because of determinate the sensitivity and specificity of different DT. Methodological standards, extensively accepted was used. In all of articles, except one (98%) the gold standard was specified yours use, however in 4 studies (9%) include the DT in the gold standard (incorporation bias). The correct description of DT was reported in 75% of cases, but only in 11% cases the reproducibility of test was evaluated. The description of source of reference population, standard of inclusion and spectrum of composition was described in 58, 33 and 40% of articles, respectively. In 33% of studies presented workup bias, only 6% commented blind-analysis of results, and 11% presented indeterminate test results. Half of the studies reported test indexes for clinical subgroups, only one article (2%) provided numerical precision for test indexes, and only 7% reported receiver operating characteristics curves. The methodological quality of DT research in the EIMC journal may improve in different aspects of design and presentation of results.

  19. Status of TMX upgrade diagnostics construction

    International Nuclear Information System (INIS)

    Hornady, R.S.; Davis, J.C.; Simonen, T.C.

    1981-01-01

    This report describes the status of the initial TMX Upgrade diagnostics and the state of development of additional diagnostics being prepared for later TMX Upgrade experiments. The initial diagnostic instrument set has been described in the TMX Upgrade Proposal. This set is required to get TMX Upgrade operational and to evaluate its initial performance. Additional diagnostic instruments are needed to then carry out the more detailed experiments outlined by the TMX Upgrade program milestones. The relation of these new measurements to the physics program is described in The TMX Upgrade Program Plan

  20. Implementation of Point-of-Care Diagnostics in Rural Primary Healthcare Clinics in South Africa: Perspectives of Key Stakeholders.

    Science.gov (United States)

    Mashamba-Thompson, Tivani P; Jama, Ngcwalisa A; Sartorius, Benn; Drain, Paul K; Thompson, Rowan M

    2017-01-08

    Key stakeholders' involvement is crucial to the sustainability of quality point-of-care (POC) diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC) clinics in South Africa. We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO) quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it) criteria for POC diagnostic services in resource-limited settings. 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients' needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics.

  1. Implementation of Point-of-Care Diagnostics in Rural Primary Healthcare Clinics in South Africa: Perspectives of Key Stakeholders

    Directory of Open Access Journals (Sweden)

    Tivani P. Mashamba-Thompson

    2017-01-01

    Full Text Available Introduction: Key stakeholders’ involvement is crucial to the sustainability of quality point-of-care (POC diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC clinics in South Africa. Method: We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it criteria for POC diagnostic services in resource-limited settings. Results: 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients’ needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Conclusions: Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics.

  2. Addressing the challenges of diagnostics demand and supply: insights from an online global health discussion platform.

    Science.gov (United States)

    Engel, Nora; Wachter, Keri; Pai, Madhukar; Gallarda, Jim; Boehme, Catharina; Celentano, Isabelle; Weintraub, Rebecca

    2016-01-01

    Several barriers challenge development, adoption and scale-up of diagnostics in low and middle income countries. An innovative global health discussion platform allows capturing insights from the global health community on factors driving demand and supply for diagnostics. We conducted a qualitative content analysis of the online discussion 'Advancing Care Delivery: Driving Demand and Supply of Diagnostics' organised by the Global Health Delivery Project (GHD) (http://www.ghdonline.org/) at Harvard University. The discussion, driven by 12 expert panellists, explored what must be done to develop delivery systems, business models, new technologies, interoperability standards, and governance mechanisms to ensure that patients receive the right diagnostic at the right time. The GHD Online (GHDonline) platform reaches over 19 000 members from 185 countries. Participants (N=99) in the diagnostics discussion included academics, non-governmental organisations, manufacturers, policymakers, and physicians. Data was coded and overarching categories analysed using qualitative data analysis software. Participants considered technical characteristics of diagnostics as smaller barriers to effective use of diagnostics compared with operational and health system challenges, such as logistics, poor fit with user needs, cost, workforce, infrastructure, access, weak regulation and political commitment. Suggested solutions included: health system strengthening with patient-centred delivery; strengthened innovation processes; improved knowledge base; harmonised guidelines and evaluation; supply chain innovations; and mechanisms for ensuring quality and capacity. Engaging and connecting different actors involved with diagnostic development and use is paramount for improving diagnostics. While the discussion participants were not representative of all actors involved, the platform enabled a discussion between globally acknowledged experts and physicians working in different countries.

  3. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  4. Computer-based diagnostic decisionmaking.

    Science.gov (United States)

    Miller, R A

    1987-12-01

    The three decisionmaking aids described by the authors attack the generic problem of "see no evil, hear no evil, speak no evil"--improving the detection, diagnosis, and therapy of psychiatric disorders in the primary care setting. The three systems represent interventions at different steps in the process of providing appropriate care to psychiatric patients. The DSPW system of Robins and Marcus offers the potential of increasing the recognition of psychiatric disease in the physician's office. Politser's IDS program is representative of the sort of sophisticated microcomputer-based decisionmaking support tools that will become available to physicians in the not-too-distant future. Erdman's study of the impact of explanation capabilities on the acceptability of therapy recommending systems points out the need for careful scientific evaluations of features added to diagnostic and therapeutic systems.

  5. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex.

    Science.gov (United States)

    Taylor, Samuel A; Khair, M Michael; Gulotta, Lawrence V; Pearle, Andrew D; Baret, Nikolas J; Newman, Ashley M; Dy, Christopher J; O'Brien, Stephen J

    2015-02-01

    The purpose of this study was to define the limits of diagnostic glenohumeral arthroscopy and determine the prevalence and frequency of hidden extra-articular "bicipital tunnel" lesions among chronically symptomatic patients. Eight fresh-frozen cadaveric specimens underwent diagnostic glenohumeral arthroscopy with percutaneous tagging of the long head of the biceps tendon (LHBT) during maximal tendon excursion. The percentage of visualized LHBT was calculated relative to the distal margin of subscapularis tendon and the proximal margin of the pectoralis major tendon. Then, a retrospective review of 277 patients who underwent subdeltoid transfer of the LHBT to the conjoint tendon were retrospectively analyzed for lesions of the biceps-labral complex. Lesions were categorized by anatomic location (inside, junctional, or bicipital tunnel). Inside lesions were labral tears. Junctional lesions were LHBT tears visualized during glenohumeral arthroscopy. Bicipital tunnel lesions were extra-articular lesions hidden from view during standard glenohumeral arthroscopy. Seventy-eight percent of LHBT were visualized relative to the distal margin of the subscapularis tendon and only 55% relative to the proximal margin of the pectoralis major tendon. No portion of the LHBT inferior to the subscapularis tendon was visualized. Forty-seven percent of patients had hidden bicipital tunnel lesions. Scarring was most common and accounted for 48% of all such lesions. Thirty-seven percent of patients had multiple lesion locations. Forty-five percent of patients with junctional lesions also had hidden bicipital tunnel lesions. The only offending lesion was in the bicipital tunnel for 18% of patients. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex because it visualizes only 55% of the LHBT relative to the proximal margin of the pectoralis major tendon and did not identify extra-articular bicipital tunnel lesions present in 47% of chronically

  6. Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration,operation, improvements

    Czech Academy of Sciences Publication Activity Database

    Böhm, Petr; Aftanas, Milan; Bílková, Petra; Štefániková, Estera; Mikulín, Ondřej; Melich, Radek; Janky, Filip; Havlíček, Josef; Šesták, David; Weinzettl, Vladimír; Stöckel, Jan; Hron, Martin; Pánek, Radomír; Scannell, R.; Frassinetti, L.; Fassina, A.; Naylor, G.; Walsh, M.J.

    2014-01-01

    Roč. 85, č. 11 (2014), 11E431-11E431 ISSN 0034-6748. [Topical Conference on High-Temperature Plasma Diagnostics/20./. Atlanta, Georgia, 01.06.2014-05.06.2014] R&D Projects: GA MŠk(CZ) LM2011021; GA ČR(CZ) GA14-35260S Institutional support: RVO:61389021 Keywords : plasma * tokamak * pedestal * Thomson scattering * diagnostic Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.614, year: 2014 http://scitation.aip.org/content/aip/journal/rsi/85/11/10.1063/1.4893995

  7. Evaluation of the e-Learning material developed by EMERALD and EMIT for diagnostic imaging and radiotherapy.

    Science.gov (United States)

    Aitken, Victoria; Tabakov, Slavik

    2005-09-01

    Two Leonardo projects, EMERALD and EMIT, have developed in a partnershipof university and hospital departments (the consortia) e-Learning materials in X-ray diagnostic radiology, nuclear medicine, radiotherapy, ultrasound and magnetic resonance imaging for medical physics graduates and other healthcare professionals. These e-Learning materials are described in a separate paper in this issue. To assess the effectiveness and relevance of the e-Learning material, a series of evaluations by student users groups plus experts in medical physics education and training were undertaken. The students, with backgrounds in physics and clinical ultrasound, reviewed the e-Learning material using an evaluation form developed by the consortia. The student feedback was favourable with students commenting that their level of knowledge had increased having completed the tasks. Areas identified for development were a reduction in text volume and an increase in the time allowed for completion of some tasks. The feedback from the experts was positive with an overall appreciation of the value of the learning material as a resource for students in medical physics field across Europe and identified other disciplines in which the access to the learning material could be useful contribution to their learning. Suggestions made for improvements ranged from grading the tasks into basic and advanced topics to increasing the interactive nature of the material. These early evaluation of the e-Learning material look promising and provide a framework for further developments in the field. Insight into users and providers views is important if developers are to provide relevant and worthwhile educational learning opportunities.

  8. Process signal selection method to improve the impact mitigation of sensor broken for diagnosis using machine learning

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents of industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning are expected to detect early and correctly abnormality occurred in a plant. However, the general diagnostic machines are generated generally to require all process signals (hereafter, signals) for plant diagnosis. Thus if trouble occurs such as process sensor is broken, the diagnostic machine cannot diagnose or may decrease diagnostic performance. Therefore, we propose an important process signal selection method to improve impact mitigation without reducing the diagnostic performance by reducing the adverse effect of noises on multi-agent diagnostic system. The advantage of our method is the general-purpose property that allows to be applied to various supervised machine learning and to set the various parameters to decide termination of search. The experiment evaluation revealed that diagnostic machines generated by our method using SVM improved the impact mitigation and did not reduce performance about the diagnostic accuracy, the velocity of diagnosis, predictions of plant state near accident occurrence, in comparison with the basic diagnostic machine which diagnoses by using all signals. This paper reports our proposed method and the results evaluated which our method was applied to the simulated abnormal of the fast-breeder reactor Monju. (author)

  9. Diagnostic Bias and Conduct Disorder: Improving Culturally Sensitive Diagnosis

    Science.gov (United States)

    Mizock, Lauren; Harkins, Debra

    2011-01-01

    Disproportionately high rates of Conduct Disorder are diagnosed in African American and Latino youth of color. Diagnostic bias contributes to overdiagnosis of Conduct Disorder in these adolescents of color. Following a diagnosis of Conduct Disorder, adolescents of color face poorer outcomes than their White counterparts. These negative outcomes…

  10. Influence of companion diagnostics on efficacy and safety of targeted anti-cancer drugs: systematic review and meta-analyses.

    Science.gov (United States)

    Ocana, Alberto; Ethier, Josee-Lyne; Díez-González, Laura; Corrales-Sánchez, Verónica; Srikanthan, Amirrtha; Gascón-Escribano, María J; Templeton, Arnoud J; Vera-Badillo, Francisco; Seruga, Bostjan; Niraula, Saroj; Pandiella, Atanasio; Amir, Eitan

    2015-11-24

    Companion diagnostics aim to identify patients that will respond to targeted therapies, therefore increasing the clinical efficacy of such drugs. Less is known about their influence on safety and tolerability of targeted anti-cancer agents. Randomized trials evaluating targeted agents for solid tumors approved by the US Food and Drug Administration since year 2000 were assessed. Odds ratios (OR) and and 95% confidence intervals (CI) were computed for treatment-related death, treatment-discontinuation related to toxicity and occurrence of any grade 3/4 adverse events (AEs). The 12 most commonly reported individual AEs were also explored. ORs were pooled in a meta-analysis. Analysis comprised 41 trials evaluating 28 targeted agents. Seventeen trials (41%) utilized companion diagnostics. Compared to control groups, targeted drugs in experimental arms were associated with increased odds of treatment discontinuation, grade 3/4 AEs, and toxic death irrespective of whether they utilized companion diagnostics or not. Compared to drugs without available companion diagnostics, agents with companion diagnostics had a lower magnitude of increased odds of treatment discontinuation (OR = 1.12 vs. 1.65, p diagnostics were greatest for diarrhea (OR = 1.29 vs. 2.43, p diagnostics are associated with improved safety, and tolerability. Differences were most marked for gastrointestinal, cutaneous and neurological toxicity.

  11. Diagnostics for pellet experiments

    International Nuclear Information System (INIS)

    Johnson, R.R.

    1978-01-01

    The target diagnostics which are being used and planned in current laser driven ICF Experiments are described. Most of these diagnostics can be easily applied to future ion-beam fusion experiments. The status of laser fusion diagnostics has been much improved in the last 5 years and further improvements can be expected and should be available when the first ICF experiments using ion beams are performed. As an example, x-ray temporal and spatial resolutions are now approximately 5 psec and 3 μm, which is approximately a factor of 4 better than the resolution reported in the first implosion experiments. As one plans ahead for ion-beam fusion experiments it should be emphasized that high yield experiments are easier to diagnose provided adequate shielding is employed. However, in the event that the first high yield experiments fail it will be necessary to have diagnostics available to determine where the problems lie. In laser fusion it is interesting to note that higher laser powers are required now for breakeven experiments than first anticipated, mainly because some aspects of the laser-interaction physics were not recognized until the experiments were carefully diagnosed. Thus as has been pointed out, it may be necessary to increase the energy of the ion-beam driver to enable us to do breakeven experiments with high confidence

  12. Comparing diagnostic tests on benefit-risk.

    Science.gov (United States)

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  13. Evaluation of the accuracy of diagnostic scales for a syndrome in Chinese medicine in the absence of a gold standard.

    Science.gov (United States)

    Wang, Xiao Nan; Zhou, Vanessa; Liu, Qiang; Gao, Ying; Zhou, Xiao-Hua

    2016-01-01

    The concept of syndromes (zhengs) is unique to Chinese medicine (CM) and difficult to measure. Expert consensus is used as a gold standard to identify zhengs and evaluate the accuracy of existing diagnostic scales for zhengs. But, the use of expert consensus as a gold standard is problematic because the diagnosis of zhengs by expert consensus is not 100 % accurate. This study aimed to evaluate the accuracy of standardized diagnostic scales for a syndrome zhengs in the absence of a gold standard, with application to internal wind (nei feng) syndrome in ischemic stroke patients. A total of 204 participants (age 41-84 years) with ischemic stroke were assessed by the stroke syndrome differentiation diagnostic criterion (SSDC), ischemic stroke TCM syndrome diagnostic scale (ISDS), and expert syndrome differentiation (ESD). The diagnostic tests and data collection process were conducted over a 10-month period (February 2008 to November 2008) in 10 hospitals across nine cities in China. The Bayesian method was used to estimate the accuracy of the SSDC, ISDS, and ESD. For internal wind syndrome, the estimated sensitivities and specificities of the SSDC, ISDS, and ESD without use of a gold standard were respectively: [Formula: see text], [Formula: see text]; [Formula: see text], [Formula: see text]; and [Formula: see text], [Formula: see text]. After adjusting for imperfect gold standard bias, we found that both the sensitivity and specificity of the ISDS were higher than those of the SSDC for diagnosis of internal wind syndrome in ischemic stroke patients.

  14. Molecular diagnostics: the changing culture of medical microbiology.

    Science.gov (United States)

    Bullman, Susan; Lucey, Brigid; Sleator, Roy D

    2012-01-01

    Diagnostic molecular biology is arguably the fastest growing area in current laboratory-based medicine. Growth of the so called 'omics' technologies has, over the last decade, led to a gradual migration away from the 'one test, one pathogen' paradigm, toward multiplex approaches to infectious disease diagnosis, which have led to significant improvements in clinical diagnostics and ultimately improved patient care.

  15. Developing diagnostic guidelines for the acute radiation syndrome

    International Nuclear Information System (INIS)

    Densow, D.; Fliedner, T.M.; Kindler, H.

    1996-01-01

    Diagnostic guidelines seem to be promising for improving medical care. One aspect of a diagnostic guideline for the acute radiation syndrome has been tested against an extensive case history database. Subsequently, the guideline has been optimized for a small set of case histories. The improved performance has been proven by a test against the rest of the case history database

  16. DIAGNOSTIC OF CNC LATHE WITH QC 20 BALLBAR SYSTEM

    Directory of Open Access Journals (Sweden)

    Jerzy Józwik

    2015-11-01

    Full Text Available This paper presents the evaluation of the influence of the feedmotion speed on the value of selected geometric errors of CNC lathe CTX 310 eco by DMG, indentified by QC 20 Ballbar system. Diagnostically evaluated were: the deviation of the axis squareness, reversal spike, and backlash. These errors determine the forming of the dimensional and shape accuracy of a machine tool. The article discusses the process of the CNC diagnostic test, the diagnostic evaluation and formulates guidelines on further CNC operation. The results of measurements were presented in tables and diagrams.

  17. Magnetic resonance imaging of the wrist: Diagnostic performance statistics

    International Nuclear Information System (INIS)

    Hobby, Jonathan L.; Tom, Brian D.M.; Bearcroft, Philip W.P.; Dixon, Adrian K.

    2001-01-01

    AIM: To review the published diagnostic performance statistics for magnetic resonance imaging (MRI) of the wrist for tears of the triangular fibrocartilage complex, the intrinsic carpal ligaments, and for osteonecrosis of the carpal bones. MATERIALS AND METHODS: We used Medline and Embase to search the English language literature. Studies evaluating the diagnostic performance of MRI of the wrist in living patients with surgical confirmation of MR findings were identified. RESULTS: We identified 11 studies reporting the diagnostic performance of MRI for tears of the triangular fibrocartilage complex for a total of 410 patients, six studies for the scapho-lunate ligament (159 patients), six studies for the luno-triquetral ligament (142 patients) and four studies (56 patients) for osteonecrosis of the carpal bones. CONCLUSIONS: Magnetic resonance imaging is an accurate means of diagnosing tears of the triangular fibrocartilage and carpal osteonecrosis. Although MRI is highly specific for tears of the intrinsic carpal ligaments, its sensitivity is low. The diagnostic performance of MRI in the wrist is improved by using high-resolution T2* weighted 3D gradient echo sequences. Using current imaging techniques without intra-articular contrast medium, magnetic resonance imaging cannot reliably exclude tears of the intrinsic carpal ligaments. Hobby, J.L. (2001)

  18. Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions.

    Science.gov (United States)

    Makris, D; Scherpereel, A; Leroy, S; Bouchindhomme, B; Faivre, J-B; Remy, J; Ramon, P; Marquette, C-H

    2007-06-01

    The present study prospectively evaluated the diagnostic yield and safety of electromagnetic navigation-guided bronchoscopy biopsy, for small peripheral lung lesions in patients where standard techniques were nondiagnostic. The study was conducted in a tertiary medical centre on 40 consecutive patients considered unsuitable for straightforward surgery or computed tomography (CT)-guided transthoracic needle aspiration biopsy, due to comorbidities. The lung lesion diameter was mean+/-sem 23.5+/-1.5 mm and the depth from the visceral-costal pleura was 14.9+/-2 mm. Navigation was facilitated by an electromagnetic tracking system which could detect a position sensor incorporated into a flexible catheter advanced through a bronchoscope. Information obtained during bronchoscopy was superimposed on previously acquired CT data. Divergence between CT data and data obtained during bronchoscopy was calculated by the system's software as a measure of navigational accuracy. All but one of the target lesions was reached and the overall diagnostic yield was 62.5% (25-40). Diagnostic yield was significantly affected by CT-to-body divergence; yield was 77.2% when estimated divergence was drainage was required in one case. Electromagnetic navigation-guided bronchoscopy has the potential to improve the diagnostic yield of transbronchial biopsies without additional fluoroscopic guidance, and may be useful in the early diagnosis of lung cancer, particularly in nonoperable patients.

  19. Benchmarking outcomes in the Neonatal Intensive Care Unit: Cytogenetic and molecular diagnostic rates in a retrospective cohort.

    Science.gov (United States)

    Malam, Faheem; Hartley, Taila; Gillespie, Meredith K; Armour, Christine M; Bariciak, Erika; Graham, Gail E; Nikkel, Sarah M; Richer, Julie; Sawyer, Sarah L; Boycott, Kym M; Dyment, David A

    2017-05-09

    Genetic disease and congenital anomalies continue to be a leading cause of neonate mortality and morbidity. A genetic diagnosis in the neonatal intensive care unit (NICU) can be a challenge given the associated genetic heterogeneity and early stage of a disease. We set out to evaluate the outcomes of Medical Genetics consultation in the NICU in terms of cytogenetic and molecular diagnostic rates and impact on management. We retrospectively reviewed 132 charts from patients admitted to the NICU who received a Medical Genetics diagnostic evaluation over a 2 year period. Of the 132 patients reviewed, 26% (34/132) received a cytogenetic or molecular diagnosis based on the Medical Genetics diagnostic evaluation; only 10% (13/132) received a diagnosis during their admission. The additional 16% (21 patients) received their diagnosis following NICU discharge, but based on a genetic test initiated during hospital-stay. Mean time from NICU admission to confirmed diagnosis was 24 days. For those who received a genetic diagnosis, the information was considered beneficial for clinical management in all, and a direct change to medical management occurred for 12% (4/32). For those non-diagnosed infants seen in out-patient follow-up clinic, diagnoses were made in 8% (3/37). The diagnoses made post-discharge from the NICU comprised a greater number of Mendelian disorders and represent an opportunity to improve genetic care. The adoption of diagnostic tools, such as exome sequencing, used in parallel with traditional approaches will improve rate of diagnoses and will have a significant impact, in particular when the differential diagnosis is broad. © 2017 Wiley Periodicals, Inc.

  20. Cancer pancreatis, diagnostic procedures

    International Nuclear Information System (INIS)

    Graadal, Oe.; Schlichting, E.; Aasen, A.O.; Stadaas, J.O.

    1990-01-01

    151 patients treated for carcinoma of the pancreas at Ullevaal Hospital (Oslo University) during the period 1980-89 were studied. The most common initial symptom was abdominal pain. Other frequent debut symptoms were loss of weight and jaundice. ERCP and PTC were found to be the best diagnostic procedures. CT or ultrasonography were normal in 10-20% of the patients. Nearly all tumors of the pancreas were found by the ERCP procedure. Also angiography was used to evaluate operability of the pancreas tumor, but was found to be a very uncertain diagnostic method. This method will not be used in the future evaluation of patients with cancer of the pancreas. 13 refs., 1 fig., 2 tabs

  1. Can rapid integrated polymerase chain reaction-based diagnostics for gastrointestinal pathogens improve routine hospital infection control practice? A diagnostic study.

    Science.gov (United States)

    Pankhurst, Louise; Macfarlane-Smith, Louissa; Buchanan, James; Anson, Luke; Davies, Kerrie; O'Connor, Lily; Ashwin, Helen; Pike, Graham; Dingle, Kate E; Peto, Timothy Ea; Wordsworth, Sarah; Walker, A Sarah; Wilcox, Mark H; Crook, Derrick W

    2014-08-01

    Every year approximately 5000-9000 patients are admitted to a hospital with diarrhoea, which in up to 90% of cases has a non-infectious cause. As a result, single rooms are 'blocked' by patients with non-infectious diarrhoea, while patients with infectious diarrhoea are still in open bays because of a lack of free side rooms. A rapid test for differentiating infectious from non-infectious diarrhoea could be very beneficial for patients. To evaluate MassCode multiplex polymerase chain reaction (PCR) for the simultaneous diagnosis of multiple enteropathogens directly from stool, in terms of sensitivity/specificity to detect four common important enteropathogens: Clostridium difficile, Campylobacter spp., Salmonella spp. and norovirus. A retrospective study of fixed numbers of samples positive for C. difficile (n = 200), Campylobacter spp. (n = 200), Salmonella spp. (n = 100) and norovirus (n = 200) plus samples negative for all these pathogens (n = 300). Samples were sourced from NHS microbiology laboratories in Oxford and Leeds where initial diagnostic testing was performed according to Public Health England methodology. Researchers carrying out MassCode assays were blind to this information. A questionnaire survey, examining current practice for infection control teams and microbiology laboratories managing infectious diarrhoea, was also carried out. MassCode assays were carried out at Oxford University Hospitals NHS Trust. Further multiplex assays, carried out using Luminex, were run on the same set of samples at Leeds Teaching Hospitals NHS Trust. The questionnaire was completed by various NHS trusts. Sensitivity and specificity to detect C. difficile, Campylobacter spp., Salmonella spp., and norovirus. Nucleic acids were extracted from 948 clinical samples using an optimised protocol (200 Campylobacter spp., 199 C. difficile, 60 S. enterica, 199 norovirus and 295 negative samples; some samples contained more than one pathogen). Using the Mass

  2. Quality of life evaluation of workers for diagnostic radiology services

    International Nuclear Information System (INIS)

    Fernandes, Ivani Martins

    2011-01-01

    The main objective of this study was to evaluate the quality of life (QOL) of diagnostic radiology services workers at a hospital of Sao Paulo city. It aimed also to draw the profile of these workers identifying the variables, as its influence on their quality of life. A descriptive exploratory study with qualitative and quantitative approaches was carried out. The data were collected using the questionnaires: the abbreviated instrument for the assessment of the QOL, World Health Organization Quality of Life Instrument bref (WHOQOL-bref) and a questionnaire including the social demographic variables, work conditions and the variables that express the lifestyle of individuals, both questionnaires self-applied. The sample was formed by 118 workers, among them: physicians, technologists/technicians in radiology, nurses, technicians and assistants in nursing, and others health professionals. The data analysis included descriptive statistics, nonparametric tests and the use of a linear regression model. The reliability of the instrument for the studied sample was verified by Cronbach's Alpha Coefficient (α). The WHOQOL-bref proved to be an adequate instrument, with a good level of internal consistency (α=0.884), being easily and quickly administrated for the evaluation of the QOL. The study provided an overview of the perception of quality of life of the studied group. (author)

  3. The diagnostic work up of growth failure in secondary health care; An evaluation of consensus guidelines

    Directory of Open Access Journals (Sweden)

    Dekker Friedo W

    2008-05-01

    Full Text Available Abstract Background As abnormal growth might be the first manifestation of undetected diseases, it is important to have accurate referral criteria and a proper diagnostic work-up. In the present paper we evaluate the diagnostic work-up in secondary health care according to existing consensus guidelines and study the frequency of underlying medical disorders. Methods Data on growth and additional diagnostic procedures were collected from medical records of new patients referred for short stature to the outpatient clinics of the general paediatric departments of two hospitals (Erasmus MC – Sophia Children's Hospital, Rotterdam and Spaarne Hospital, Haarlem between January 1998 and December 2002. As the Dutch Consensus Guideline (DCG is the only guideline addressing referral criteria as well as diagnostic work-up, the analyses were based on its seven auxological referral criteria to determine the characteristics of children who are incorrectly referred and the adequacy of workup of those who are referred. Results Twenty four percent of children older than 3 years were inappropriately referred (NCR. Of the correctly referred children 74–88% were short corrected for parental height, 40–61% had a height SDS Conclusion Existing guidelines for workup of children with suspected growth failure are poorly implemented. Although poorly implemented the DCG detects at least 5% pathologic causes of growth failure in children referred for short stature. New guidelines for referral are required with a better sensitivity and specificity, wherein distance to target height should get more attention. The general diagnostic work up for short stature should include testing for celiac disease in all children and for Turner syndrome in girls.

  4. Validation of the Gambling Disorder Screening Questionnaire, a self-administered diagnostic questionnaire for gambling disorder based on the DSM-5 criteria.

    Science.gov (United States)

    Villella, Corrado; Pascucci, Marco; de Waure, Chiara; Bellomo, Antonello; Conte, Gianluigi

    2016-01-01

    The DSM-5 has modified the diagnostic criteria for gambling disorder, compared to the fourth edition of the manual; new diagnostic instruments are therefore needed. This study evaluated the psychometric characteristics of the Gambling Disorder Screening Questionnaire (GDSQ), a self-report questionnaire based on the DSM-IV and DSM-5 criteria for Gambling Disorder, measuring its validity, internal consistency, and submitting the questionnaire to a principal components analysis. 71 patients from a gambling disorder outpatient clinic and 70 controls were evaluated with the GDSQ, the South Oaks Gambling Screen (SOGS), and a psychiatric interview. The test showed a good sensibility, specificity, internal consistency, concurrent validity with the SOGS. The exclusion of the “illegal acts” item, and the lowering of the cut-off score to four positive items, as suggested by the DSM-5 criteria, improved the test sensibility and internal consistency. The GDSQ can be considered a useful screening test for Gambling Disorder. Furthermore, this study confirms the improved diagnostic accuracy of the criteria listed in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders, compared to the previous edition.

  5. Improved diagnostic accuracy of Alzheimer's disease by combining regional cortical thickness and default mode network functional connectivity: Validated in the Alzheimer's disease neuroimaging initiative set

    International Nuclear Information System (INIS)

    Park, Ji Eun; Park, Bum Woo; Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Jung; Oh, Joo Young; Shim, Woo Hyun; Lee, Jae Hong; Roh, Jee Hoon

    2017-01-01

    To identify potential imaging biomarkers of Alzheimer's disease by combining brain cortical thickness (CThk) and functional connectivity and to validate this model's diagnostic accuracy in a validation set. Data from 98 subjects was retrospectively reviewed, including a study set (n = 63) and a validation set from the Alzheimer's Disease Neuroimaging Initiative (n = 35). From each subject, data for CThk and functional connectivity of the default mode network was extracted from structural T1-weighted and resting-state functional magnetic resonance imaging. Cortical regions with significant differences between patients and healthy controls in the correlation of CThk and functional connectivity were identified in the study set. The diagnostic accuracy of functional connectivity measures combined with CThk in the identified regions was evaluated against that in the medial temporal lobes using the validation set and application of a support vector machine. Group-wise differences in the correlation of CThk and default mode network functional connectivity were identified in the superior temporal (p < 0.001) and supramarginal gyrus (p = 0.007) of the left cerebral hemisphere. Default mode network functional connectivity combined with the CThk of those two regions were more accurate than that combined with the CThk of both medial temporal lobes (91.7% vs. 75%). Combining functional information with CThk of the superior temporal and supramarginal gyri in the left cerebral hemisphere improves diagnostic accuracy, making it a potential imaging biomarker for Alzheimer's disease

  6. Improving evaluation at two medical schools.

    Science.gov (United States)

    Schiekirka-Schwake, Sarah; Dreiling, Katharina; Pyka, Katharina; Anders, Sven; von Steinbüchel, Nicole; Raupach, Tobias

    2017-08-03

    Student evaluations of teaching can provide useful feedback for teachers and programme coordinators alike. We have designed a novel evaluation tool assessing teacher performance and student learning outcome. This tool was implemented at two German medical schools. In this article, we report student and teacher perceptions of the novel tool, and the implementation process. Focus group discussions as well as one-to-one interviews involving 22 teachers and 31 undergraduate medical students were conducted. Following adjustments to the feedback reports (e.g. the colour coding of results) at one medical school, 42 teachers were asked about their perceptions of the revised report and the personal benefit of the evaluation tool. Teachers appreciated the individual feedback provided by the evaluation tool and stated that they wanted to improve their teaching, based on the results; however, they missed most of the preparative communication. Students were unsure about the additional benefit of the instrument compared with traditional evaluation tools. A majority was unwilling to complete evaluation forms in their spare time, and some felt that the new questionnaire was too long and that the evaluations occurred too often. They were particularly interested in feedback on how their comments have helped to further improve teaching. Student evaluations of teaching can provide useful feedback CONCLUSION: Despite evidence of the utility of the tool for individual teachers, implementation of changes to the process of evaluation appears to have been suboptimal, mainly owing to a perceived lack of communication. In order to motivate students to provide evaluation data, feedback loops including aims and consequences should be established. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  7. Diagnostic omission errors in acute paediatric practice: impact of a reminder system on decision-making

    Directory of Open Access Journals (Sweden)

    Fisher Helen

    2006-11-01

    Full Text Available Abstract Background Diagnostic error is a significant problem in specialities characterised by diagnostic uncertainty such as primary care, emergency medicine and paediatrics. Despite wide-spread availability, computerised aids have not been shown to significantly improve diagnostic decision-making in a real world environment, mainly due to the need for prolonged system consultation. In this study performed in the clinical environment, we used a Web-based diagnostic reminder system that provided rapid advice with free text data entry to examine its impact on clinicians' decisions in an acute paediatric setting during assessments characterised by diagnostic uncertainty. Methods Junior doctors working over a 5-month period at four paediatric ambulatory units consulted the Web-based diagnostic aid when they felt the need for diagnostic assistance. Subjects recorded their clinical decisions for patients (differential diagnosis, test-ordering and treatment before and after system consultation. An expert panel of four paediatric consultants independently suggested clinically significant decisions indicating an appropriate and 'safe' assessment. The primary outcome measure was change in the proportion of 'unsafe' workups by subjects during patient assessment. A more sensitive evaluation of impact was performed using specific validated quality scores. Adverse effects of consultation on decision-making, as well as the additional time spent on system use were examined. Results Subjects attempted to access the diagnostic aid on 595 occasions during the study period (8.6% of all medical assessments; subjects examined diagnostic advice only in 177 episodes (30%. Senior House Officers at hospitals with greater number of available computer workstations in the clinical area were most likely to consult the system, especially out of working hours. Diagnostic workups construed as 'unsafe' occurred in 47/104 cases (45.2%; this reduced to 32.7% following system

  8. The diagnostic protocol for evaluation of periprosthetic joint infection

    Directory of Open Access Journals (Sweden)

    Alen Mlekuž

    2015-06-01

    Full Text Available Infection is becoming the most important as well as the most devastating mechanism of prosthetic joint failure. The incidence is increasing due to increased sensitivity of orthopedic surgeons for this diagnosis, better diagnostics, and  because the absolute number of operated patients is increasing and because more often very sick, debilitated, and immunocompromised patients are operated on. The trend shows the incidence to further increase in the years to come. The diagnosis may be very easy in case of high grade processes, but also extremely difficult in low grade infections. Misdiagnosing infection leads to repeat early failures and revisions that are distressing for patients as well as for surgeons. To avoid failures related to misdiagnosed prosthetic joint infections a step-wise algorithm of action is proposed and the diagnostic strength of the steps discussed. The key point is to select the potential candidates to define the possibility of an ongoing infection and then to select the tools to strengthen the suspicion. The further procedures base on the analysis of the pseudo-synovial fluid obtained by aspiration. The diagnostic conclusions form the basis for considered treatment decisions.

  9. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use.

    Science.gov (United States)

    Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo

    2018-03-16

    Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of entrance skin dose to the skull in diagnostic radiology

    International Nuclear Information System (INIS)

    Mohamed, Anas Ali Elbushari

    2015-12-01

    Diagnostic x-ray radiology is a common diagnostic practice.Despite of its increasing hazard to human beings, imaging procedures should be achieved with less radiation dose and sufficient image quality. The aim of this study was to estimate the entrance skin dose(ESD) for patients undergoing selected diagnostic x-ray examinations in four hospitals.The study included the examinations of the skull; posterior- anterior(PA) and lateral projections. Fifty patients were enrolled in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μGy/mAs) and tube voltage(kVp). The estimated ESDs ranged from 0.0097-0.1846 mGy for skull (PA), 0.0097-0.1399 mGy for skull (LAT). These values were acceptable as compared with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose levels for diagnostic radiology in Sudan.(Author)

  11. Expert system for fast reactor diagnostic

    International Nuclear Information System (INIS)

    Parcy, J.P.

    1982-09-01

    A general description of expert systems is given. The operation of a fast reactor is reviewed. The expert system to the diagnosis of breakdowns limited to the reactor core. The structure of the system is described: specification of the diagnostics; structure of the data bank and evaluation of the rules; specification of the prediagnostics and evaluation; explanation of the diagnostics; time evolution of the system; comparison with other expert systems. Applications to some cases of faults are finally presented [fr

  12. Maladaptive eating behavior assessment among bariatric surgery candidates: Evaluation of the Eating Disorder Diagnostic Scale.

    Science.gov (United States)

    Williams, Gail A; Hawkins, Misty A W; Duncan, Jennifer; Rummell, Christina M; Perkins, Shannon; Crowther, Janis H

    2017-07-01

    Eating pathology among bariatric surgery candidates is common and associated with adverse outcomes. However, its assessment is complicated by the inconsistent use of standardized measures. We addressed this by examining the use of the Eating Disorder Diagnostic Scale (EDDS) in a large bariatric sample (N = 343). To evaluate the EDDS among bariatric surgery candidates via examination of: (1) Diagnostic and Statistical Manual of Mental Disorders, fourth edition, text revision (DSM-IV-TR) and fifth edition (DSM-5) rates of binge eating disorder, bulimia nervosa, and maladaptive eating behaviors, and (2) the relationship between response biases and self-reported eating disorder symptoms. Participants were bariatric surgery candidates at a large public hospital in the Midwest. As part of a larger preoperative evaluation, 343 patients seeking bariatric surgery completed the EDDS and measures of problematic response bias. Approximately 16% of the sample met full threshold criteria for binge eating disorder using DSM-5 criteria. Using the DSM-IV-TR, rates were lower but still substantial at 13%. Rates for bulimia nervosa were 8% (DSM-5) and 6% (DSM-IV-TR). The majority (66.1%) of participants reported at least one binge-eating episode per week. The most commonly used compensatory behavior was fasting (20.4%), followed by excessive exercise (11.7%), laxative use (5.6%), and vomiting (1.8%). An inverse relationship between severity of the eating symptomatology and problematic response bias emerged. The EDDS shows promise as a screening tool that uses diagnostic criteria to provide rates of binge eating and eating psychopathology among surgical candidates. Our findings suggest that subsequent validation studies of this measure are needed, should address potential response bias concerns, and should employ clear definitions of binge eating to promote standardization of eating pathology assessment in the bariatric population. Copyright © 2017 American Society for Bariatric

  13. Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease

    Directory of Open Access Journals (Sweden)

    Fan Vincent C

    2006-05-01

    Full Text Available Abstract Background Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. Methods Dry eye patients (16 eyes, who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test ( Results Ten minutes after fluorescein installition, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 ± 202.67 ng/ml compared with that of normal subjects (mean = 128.19 ± 85.84 ng/ml. Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 ± 52.83 ng/ml compared with that of controls (mean = 40.64 ± 7.96 ng/ml, averaging a three-fold increase. Conclusion Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease.

  14. Modeling sequential context effects in diagnostic interpretation of screening mammograms.

    Science.gov (United States)

    Alamudun, Folami; Paulus, Paige; Yoon, Hong-Jun; Tourassi, Georgia

    2018-07-01

    Prior research has shown that physicians' medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist's visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist's current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski-Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists' current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about

  15. Structured syncope care pathways based on lean six sigma methodology optimises resource use with shorter time to diagnosis and increased diagnostic yield.

    Science.gov (United States)

    Martens, Leon; Goode, Grahame; Wold, Johan F H; Beck, Lionel; Martin, Georgina; Perings, Christian; Stolt, Pelle; Baggerman, Lucas

    2014-01-01

    To conduct a pilot study on the potential to optimise care pathways in syncope/Transient Loss of Consciousness management by using Lean Six Sigma methodology while maintaining compliance with ESC and/or NICE guidelines. Five hospitals in four European countries took part. The Lean Six Sigma methodology consisted of 3 phases: 1) Assessment phase, in which baseline performance was mapped in each centre, processes were evaluated and a new operational model was developed with an improvement plan that included best practices and change management; 2) Improvement phase, in which optimisation pathways and standardised best practice tools and forms were developed and implemented. Staff were trained on new processes and change-management support provided; 3) Sustaining phase, which included support, refinement of tools and metrics. The impact of the implementation of new pathways was evaluated on number of tests performed, diagnostic yield, time to diagnosis and compliance with guidelines. One hospital with focus on geriatric populations was analysed separately from the other four. With the new pathways, there was a 59% reduction in the average time to diagnosis (p = 0.048) and a 75% increase in diagnostic yield (p = 0.007). There was a marked reduction in repetitions of diagnostic tests and improved prioritisation of indicated tests. Applying a structured Lean Six Sigma based methodology to pathways for syncope management has the potential to improve time to diagnosis and diagnostic yield.

  16. Structured syncope care pathways based on lean six sigma methodology optimises resource use with shorter time to diagnosis and increased diagnostic yield.

    Directory of Open Access Journals (Sweden)

    Leon Martens

    Full Text Available To conduct a pilot study on the potential to optimise care pathways in syncope/Transient Loss of Consciousness management by using Lean Six Sigma methodology while maintaining compliance with ESC and/or NICE guidelines.Five hospitals in four European countries took part. The Lean Six Sigma methodology consisted of 3 phases: 1 Assessment phase, in which baseline performance was mapped in each centre, processes were evaluated and a new operational model was developed with an improvement plan that included best practices and change management; 2 Improvement phase, in which optimisation pathways and standardised best practice tools and forms were developed and implemented. Staff were trained on new processes and change-management support provided; 3 Sustaining phase, which included support, refinement of tools and metrics. The impact of the implementation of new pathways was evaluated on number of tests performed, diagnostic yield, time to diagnosis and compliance with guidelines. One hospital with focus on geriatric populations was analysed separately from the other four.With the new pathways, there was a 59% reduction in the average time to diagnosis (p = 0.048 and a 75% increase in diagnostic yield (p = 0.007. There was a marked reduction in repetitions of diagnostic tests and improved prioritisation of indicated tests.Applying a structured Lean Six Sigma based methodology to pathways for syncope management has the potential to improve time to diagnosis and diagnostic yield.

  17. Instrumentation and quantitative methods of evaluation. Progress report, January 15-September 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.

    1986-09-01

    This document reports progress under grant entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Individual reports are presented on projects entitled the physical aspects of radionuclide imaging, image reconstruction and quantitative evaluation, PET-related instrumentation for improved quantitation, improvements in the FMI cyclotron for increased utilization, and methodology for quantitative evaluation of diagnostic performance

  18. Diagnostic ability of the periapical radiographs and digital image in the detection of the artificial proximal caries

    International Nuclear Information System (INIS)

    Heo, Min Suk; You, Dong Soo

    1994-01-01

    Recently, the digital image was introduced into radiological image. The digital image has the power of contrast enhancement, histogram control, and other digitally enhancement. At the point of the resolution, periapical radiograph is superior to the digital image, but enhanced digital procedure improves the diagnostic ability of the digital image. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries in conventional radiographs, digital radiographs and enhanced digital radiographs (histogram specification). ROC (Receiver Operating Characteristic) analysis and paired t-test were used for the evaluation of detectability, and following results were acquired: 1. The mean ROC area of conventional radiographs was 0.9274. 2. The mean ROC area of unenhanced digital image was 0.9168. 3. The mean ROC area of enhanced digital image was 0.9339. 4. The diagnostic ability of three imaging methods was not significant difference (p>0.05). So, the digital images had similar diagnostic ability of artificial proximal caries to conventional radiographs. If properly enhanced digital image, it may be superior to conventional radiographs.

  19. Cross-diagnostic validity of the Nottingham health profile index of distress (NHPD

    Directory of Open Access Journals (Sweden)

    Klevsgård Rosemarie

    2008-07-01

    Full Text Available Abstract Background The Nottingham Health Profile index of Distress (NHPD has been proposed as a generic undimensional 24-item measure of illness-related distress that is embedded in the Nottingham Health Profile (NHP. Data indicate that the NHPD may have psychometric advantages to the 6-dimensional NHP profile scores. Detailed psychometric evaluations are, however, lacking. Furthermore, to support the validity of the generic property of outcome measures evidence that scores can be interpreted in the same manner in different diagnostic groups are needed. It is currently unknown if NHPD scores have the same meaning across patient populations. This study evaluated the measurement properties and cross-diagnostic validity of the NHPD as a survey instrument among people with Parkinson's disease (PD and peripheral arterial disease (PAD. Methods Data from 215 (PD and 258 (PAD people were Rasch analyzed regarding model fit, reliability, differential item functioning (DIF, unidimensionality and targeting. In cases of cross-diagnostic DIF this was adjusted for and the impact of DIF on the total score and person measures was assessed. Results The NHPD was found to have good overall and individual item fit in both disorders as well as in the pooled sample, but seven items displayed signs of cross-diagnostic DIF. Following adjustment for DIF some aspects of model fit were slightly compromised, whereas others improved somewhat. DIF did not impact total NHPD scores or resulting person measures, but the unadjusted scale displayed minor signs of multidimensionality. Reliability was > 0.8 in all within- and cross-diagnostic analyses. Items tended to represent more distress (mean, 0 logits than that experienced by the sample (mean, -1.6 logits. Conclusion This study supports the within- and cross-diagnostic validity of the NHPD as a survey tool among people with PD and PAD. We encourage others to reassess available NHP data within the NHPD framework to further

  20. Survey of diagnostic and typing capacity for Clostridium difficile infection in Europe, 2011 and 2014.

    Science.gov (United States)

    van Dorp, Sofie M; Notermans, Daan W; Alblas, Jeroen; Gastmeier, Petra; Mentula, Silja; Nagy, Elisabeth; Spigaglia, Patrizia; Ivanova, Katiusha; Fitzpatrick, Fidelma; Barbut, Frédéric; Morris, Trefor; Wilcox, Mark H; Kinross, Pete; Suetens, Carl; Kuijper, Ed J

    2016-07-21

    Suboptimal laboratory diagnostics for Clostridium difficile infection (CDI) impedes its surveillance and control across Europe. We evaluated changes in local laboratory CDI diagnostics and changes in national diagnostic and typing capacity for CDI during the European C. difficile Infection Surveillance Network (ECDIS-Net) project, through cross-sectional surveys in 33 European countries in 2011 and 2014. In 2011, 126 (61%) of a convenience sample of 206 laboratories in 31 countries completed a survey on local diagnostics. In 2014, 84 (67%) of these 126 laboratories in 26 countries completed a follow-up survey. Among laboratories that participated in both surveys, use of CDI diagnostics deemed 'optimal' or 'acceptable' increased from 19% to 46% and from 10% to 15%, respectively (p  difficile typing method increased from 22/31 countries in 2011 to 26/32 countries in 2014; for PCR ribotyping from 20/31 countries to 23/32 countries, and specifically for capillary PCR ribotyping from 7/31 countries to 16/32 countries. While our study indicates improved diagnostic capability and national capacity for capillary PCR ribotyping across European laboratories between 2011 and 2014, increased use of 'optimal' diagnostics should be promoted. This article is copyright of The Authors, 2016.

  1. Method of evaluation of diagnostics reference levels in computerized tomography; Metodo de avaliacao de niveis de referencia de radiodiagnostico em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  2. The application of multiloop diagnostics model to assess and improve the economic security of enterprises

    Directory of Open Access Journals (Sweden)

    Pluzhnikov Vladimir

    2017-01-01

    Full Text Available The author’s research is dedicated to the enhancement of the level of the enterprise economic safety. This task involves developing the concept of an integrated system for early prevention of dangers and threats of business activity, substantiation of procedures for regulating the activities of the enterprise in accordance with the changing external and internal factors. Multiloop diagnostics model is proposed to identify causal relations of management dysfunction. It allows you to receive an adequate assessment of the basic parameters of activity of the enterprise and accurately identify its status. Researching problems of economic safety of the enterprise such diagnostic methods as economic and logical analysis, statistical monitoring and strategic management were applied. There was made a conclusion that a qualitative assessment is a key tool of the level assessment of the enterprise economic safety, its control, and monitoring. It allows you to get reliable information about the real possibilities of the enterprise at different stages of development, to monitor and evaluate the level of economic security, find effective solutions to transition to a higher level of economic safety of the enterprise.

  3. [Application of a continual improvement approach to selecting diagnostic markers for acute pancreatitis in an emergency department].

    Science.gov (United States)

    Salinas, María; Flores, Emilio; López-Garrigós, Maite; Díaz, Elena; Esteban, Patricia; Leiva-Salinas, Carlos

    2017-01-01

    To apply a continual improvement model to develop an algorithm for ordering laboratory tests to diagnose acute pancreatitis in a hospital emergency department. Quasi-experimental study using the continual improvement model (plan, do, check, adjust cycles) in 2 consecutive phases in emergency patients: amylase and lipase results were used to diagnose acute pancreatitis in the first phase; in the second, only lipase level was first determined; amylase testing was then ordered only if the lipase level fell within a certain range. We collected demographic data, number amylase and lipase tests ordered and the findings, final diagnosis, and the results of a questionnaire to evaluate satisfaction with emergency care. The first phase included 517 patients, of whom 20 had acute pancreatitis. For amylase testing sensitivity was 0.70; specificity, 0.85; positive predictive value (PPV), 17; and negative predictive value (NPV), 0.31. For lipase testing these values were sensitivity, 0.85; specificity, 0.96; PPV, 21, and NPV, 0.16. When both tests were done, sensitivity was 0.85; specificity 0.99; PPV, 85; and NPV, 0.15. The second phase included data for 4815 patients, 118 of whom had acute pancreatitis. The measures of diagnostic yield for the new algorithm were sensitivity, 0.92; specificity, 0.98; PPV, 46; and NPV, 0.08]. This study demonstrates a process for developing a protocol to guide laboratory testing in acute pancreatitis in the hospital emergency department. The proposed sequence of testing for pancreatic enzyme levels can be effective for diagnosing acute pancreatitis in patients with abdominal pain.

  4. Concurrent and predictive evaluation of malnutrition diagnostic measures in hip fracture inpatients: a diagnostic accuracy study.

    Science.gov (United States)

    Bell, J J; Bauer, J D; Capra, S; Pulle, R C

    2014-03-01

    Differences in malnutrition diagnostic measures impact malnutrition prevalence and outcomes data in hip fracture. This study investigated the concurrent and predictive validity of commonly reported malnutrition diagnostic measures in patients admitted to a metropolitan hospital acute hip fracture unit. A prospective, consecutive level II diagnostic accuracy study (n=142; 8 exclusions) including the International Classification of Disease, 10th Revision, Australian Modification (ICD10-AM) protein-energy malnutrition criteria, a body mass index (BMI) Patients were predominantly elderly (median age 83.5, range 50-100 years), female (68%), multimorbid (median five comorbidities), with 15% 4-month mortality. Malnutrition prevalence was lowest when assessed by BMI (13%), followed by MNA-SF (27%), ICD10-AM (48%), albumin (53%) and geriatrician assessment (55%). Agreement between measures was highest between ICD10-AM and geriatrician assessment (κ=0.61) followed by ICD10-AM and MNA-SF measures (κ=0.34). ICD10-AM diagnosed malnutrition was the only measure associated with 48-h mobilisation (35.0 vs 55.3%; P=0.018). Reduced likelihood of home discharge was predicted by ICD-10-AM (20.6 vs 57.1%; P=0.001) and MNA-SF (18.8 vs 47.8%; P=0.035). Bivariate analysis demonstrated ICD10-AM (relative risk (RR)1.2; 1.05-1.42) and MNA-SF (RR1.2; 1.0-1.5) predicted 4-month mortality. When adjusted for age, usual place of residency, comorbidities and time to surgery only ICD-10AM criteria predicted mortality (odds ratio 3.59; 1.10-11.77). Albumin, BMI and geriatrician assessment demonstrated limited concurrent and predictive validity. Malnutrition prevalence in hip fracture varies substantially depending on the diagnostic measure applied. ICD-10AM criteria or the MNA-SF should be considered for the diagnosis of protein-energy malnutrition in frail, multi-morbid hip fracture inpatients.

  5. A Framework to Debug Diagnostic Matrices

    Science.gov (United States)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  6. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity

    International Nuclear Information System (INIS)

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M.; Schlattmann, Peter; Dewey, Marc

    2013-01-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item (''Uninterpretable Results'') showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with ''no fulfilment'' increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. (orig.)

  7. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M. [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite Medical School, Department of Radiology, Berlin (Germany); Schlattmann, Peter [University Hospital of Friedrich Schiller University Jena, Department of Medical Statistics, Informatics, and Documentation, Jena (Germany); Dewey, Marc [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite Medical School, Department of Radiology, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2013-06-15

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item (''Uninterpretable Results'') showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with ''no fulfilment'' increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. (orig.)

  8. Nuclear diagnostics in support of ICF experiments

    International Nuclear Information System (INIS)

    Moran, M.J.; Hall, J.

    1996-01-01

    As the yields of Inertial Confinement Fusion (ICF) experiments increase to NIF levels new diagnostic techniques for studying details of fusion burn behavior will become feasible. The new techniques will provide improved measurements of fusion burn temperature and history. Improved temperature measurements might be achieved with magnetic spectroscopy of fusion neutrons. High-bandwidth fusion reaction history will be measured with fusion-specific γ-ray diagnostics. Additional energy-resolved γ-ray might be able to study a selection of specific behaviors during fusion burn. Present ICF yields greater than 10 13 neutrons are sufficient to demonstrate the basic methods that underlie the new techniques. As ICF yields increase, the diagnostics designs adjusted accordingly in order to provide clear and specific data on fusion burn performance

  9. Model-based evaluation of the use of polycyclic aromatic hydrocarbons molecular diagnostic ratios as a source identification tool

    International Nuclear Information System (INIS)

    Katsoyiannis, Athanasios; Breivik, Knut

    2014-01-01

    Polycyclic Aromatic Hydrocarbons (PAHs) molecular diagnostic ratios (MDRs) are unitless concentration ratios of pair-PAHs with the same molecular weight (MW); MDRs have long been used as a tool for PAHs source identification purposes. In the present paper, the efficiency of the MDR methodology is evaluated through the use of a multimedia fate model, the calculation of characteristic travel distances (CTD) and the estimation of air concentrations for individual PAHs as a function of distance from an initial point source. The results show that PAHs with the same MW are sometimes characterized by substantially different CTDs and therefore their air concentrations and hence MDRs are predicted to change as the distance from the original source increases. From the assessed pair-PAHs, the biggest CTD difference is seen for Fluoranthene (107 km) vs. Pyrene (26 km). This study provides a strong indication that MDRs are of limited use as a source identification tool. -- Highlights: • Model-based evaluation of the PAHs molecular diagnostic ratios efficiency. • Individual PAHs are characterized by different characteristic travel distances. • MDRs are proven to be a limited tool for source identification. • Use of MDRs for other environmental media is likely unfeasible. -- PAHs molecular diagnostic ratios which change greatly as a function of distance from the emitting source are improper for source identification purposes

  10. Experiences with the inspection of x-ray diagnostic workplaces in the radio hygienic subcentre of Gyoer

    International Nuclear Information System (INIS)

    Giczi, F.; Halmai, O.; Farkas, I.; Ballay, L.; Pellet, S.

    1996-01-01

    The authors present present their experiences obtained in the course of the inspection of x-ray diagnostic departments. The protocol for radiation protection survey worked out by the Operational Radiological Department of the National research Institute for Radiobiology and Radio hygiene (NRIRR) has been used. The general radiation protection conditions of x-ray diagnostic workplaces in the region of Gyoer Radio hygienic Subcentre (GyRS) are evaluated. Highlights of typical non compliancies and evaluation of dose and dose rate values measured are summarised. With regard to general radiation protection conditions of x-ray diagnostic workplaces, the following conclusions can be drawn. The optimal performance of x-ray equipment and radiation safety cannot be achieved without regular inspection and quality control activity. Radio hygienic conditions are also highly affected by the professional and radiation protection education and skill of department staff, particularly radiation protection officers and radiologists, which have to improved by regular training. (author). 8 refs., 5 figs., 4 tabs

  11. Quantifying the Accuracy of a Diagnostic Test or Marker

    NARCIS (Netherlands)

    Linnet, Kristian; Bossuyt, Patrick M. M.; Moons, Karel G. M.; Reitsma, Johannes B. R.

    2012-01-01

    BACKGROUND: In recent years, increasing focus has been directed to the methodology for evaluating (new) tests or biomarkers. A key step in the evaluation of a diagnostic test is the investigation into its accuracy. CONTENT: We reviewed the literature on how to assess the accuracy of diagnostic

  12. Can Emergency Medicine Residents Predict Cost of Diagnostic Testing?

    Directory of Open Access Journals (Sweden)

    Tainter, Christopher R

    2017-01-01

    Full Text Available Diagnostic testing represents a significant portion of healthcare spending, and cost should be considered when ordering such tests. Needless and excessive spending may occur without an appreciation of the impact on the larger healthcare system. Knowledge regarding the cost of diagnostic testing among emergency medicine (EM residents has not previously been studied. A survey was administered to 20 EM residents from a single ACGME-accredited three-year EM residency program, asking for an estimation of patient charges for 20 commonly ordered laboratory tests and seven radiological exams. We compared responses between residency classes to evaluate whether there was a difference based on level of training. The survey completion rate was 100% (20/20 residents. We noted significant discrepancies between the median resident estimates and actual charge to patient for both laboratory and radiological exams. Nearly all responses were an underestimate of the actual cost. The group median underestimation for laboratory testing was $114, for radiographs $57, and for computed tomography exams was $1,058. There was improvement in accuracy with increasing level of training. This pilot study demonstrates that EM residents have a poor understanding of the charges burdening patients and health insurance providers. In order to make balanced decisions with regard to diagnostic testing, providers must appreciate these factors. Education regarding the cost of providing emergency care is a potential area for improvement of EM residency curricula, and warrants further attention and investigation.

  13. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Hun [Kaya University, Gimhae (Korea, Republic of); Im, In Chul [Gwangju Health College University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Chosun University, Gwangju (Korea, Republic of); Kang, Se Sik [College of Health Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2009-03-15

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  14. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    International Nuclear Information System (INIS)

    Park, Ju Hun; Im, In Chul; Dong, Kyung Rae; Kang, Se Sik

    2009-01-01

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  15. Evaluation of the optimal diagnostic criteria for regional lymph node metastases of lung cancer on MR imaging by receiver operating characteristic curve

    International Nuclear Information System (INIS)

    Iwai, Naomichi; Yamaguchi, Yutaka

    1991-01-01

    MRI was performed in 78 primary lung cancer cases to evaluate the optimal diagnostic criteria for regional lymph node metastases. Receiver operating characteristic (ROC) curve analysis for 262 lymph nodes of the hilar and mediastinal regions showed that the optimal size criterion is 10 mm in the mean axis of nodal diameter. Employing this criterion, the diagnostic rates for hilar and mediastinal lymph nodes had a sensitivity of 75%, a specificity of 82%, and an overall accuracy of 79%. However, the diagnostic rates for subaortic, paraaortic, and hilar lymph nodes using the same criterion showed lower specificities than those for other nodes. It was suggested that evaluation by coronal section made the diagnosis for subaortic lymph nodes more precise. In the ROC curve analysis for each histologic type, it was thought that the optimal criterion for adenocarcinoma was 10 mm in the mean axis, and that the criteria for squamous cell carcinoma were 11 mm in the mean axis and 10 mm in the sort axis. (author)

  16. PCA3 and PCA3-Based Nomograms Improve Diagnostic Accuracy in Patients Undergoing First Prostate Biopsy

    Directory of Open Access Journals (Sweden)

    Virginie Vlaeminck-Guillem

    2013-08-01

    Full Text Available While now recognized as an aid to predict repeat prostate biopsy outcome, the urinary PCA3 (prostate cancer gene 3 test has also been recently advocated to predict initial biopsy results. The objective is to evaluate the performance of the PCA3 test in predicting results of initial prostate biopsies and to determine whether its incorporation into specific nomograms reinforces its diagnostic value. A prospective study included 601 consecutive patients addressed for initial prostate biopsy. The PCA3 test was performed before ≥12-core initial prostate biopsy, along with standard risk factor assessment. Diagnostic performance of the PCA3 test was evaluated. The three available nomograms (Hansen’s and Chun’s nomograms, as well as the updated Prostate Cancer Prevention Trial risk calculator; PCPT were applied to the cohort, and their predictive accuracies were assessed in terms of biopsy outcome: the presence of any prostate cancer (PCa and high-grade prostate cancer (HGPCa. The PCA3 score provided significant predictive accuracy. While the PCPT risk calculator appeared less accurate; both Chun’s and Hansen’s nomograms provided good calibration and high net benefit on decision curve analyses. When applying nomogram-derived PCa probability thresholds ≤30%, ≤6% of HGPCa would have been missed, while avoiding up to 48% of unnecessary biopsies. The urinary PCA3 test and PCA3-incorporating nomograms can be considered as reliable tools to aid in the initial biopsy decision.

  17. Clinical Evaluation of Iliopsoas Strain with Findings from Diagnostic Musculoskeletal Ultrasound in Agility Performance Canines – 73 Cases

    Directory of Open Access Journals (Sweden)

    Robert Cullen

    2017-06-01

    Full Text Available Objective: Iliopsoas injury and strain is a commonly diagnosed disease process, especially amongst working and sporting canines. There has been very little published literature regarding iliopsoas injuries and there is no information regarding the ultrasound evaluation of abnormal iliopsoas muscles. This manuscript is intended to describe the ultrasound findings in 73 canine agility athletes who had physical examination findings consistent with iliopsoas discomfort. The population was chosen given the high incidence of these animals for the development of iliopsoas injury; likely due to repetitive stress.Methods: Medical records of 73 agility performance canines that underwent musculoskeletal ultrasound evaluation of bilateral iliopsoas muscle groups were retrospectively reviewed. Data included signalment, previous radiographic findings, and ultrasound findings. A 3-tier grading scheme for acute strains was used while the practitioner also evaluated for evidence of chronic injury and bursitis.Results: The majority of pathologies were localised to the tendon of insertion, with the majority being low grade I-II strains (80.8%. Tendon fibre disruption (71.2% and indistinct hypoechoic lesions (91.8% were the most common of acute changes noted. Hyperechoic chronic changes were noted in 84.9 percent of cases. Acute and chronic changes were commonly seen together (62.8%.Conclusion: Diagnostic musculoskeletal ultrasound was used to identify lesions of the iliopsoas tendon consistent with acute and chronic injury, as well as identifying the region of pathology. The majority of agility performance dogs had low grade acute strains based on the tiered system, with mixed acute and chronic lesions being noted frequently.Application: Diagnostic musculoskeletal ultrasound provides a non-invasive diagnostic modality for patients suspected of having an iliopsoas strain.

  18. Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Marczak, Alana; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2017-09-15

    The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: 360° and 180° cone-beam computed tomography (CBCT) acquisition protocols. A small-volume 180° CBCT scan and a 360° CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up 360° CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intra-rater agreement. In this ex vivo study, we found that the 180° rotational acquisition was as effective as the conventional 360° rotational acquisition for the preoperative evaluation of potential mini-implant sites.

  19. Study design requirements for RNA sequencing-based breast cancer diagnostics.

    Science.gov (United States)

    Mer, Arvind Singh; Klevebring, Daniel; Grönberg, Henrik; Rantalainen, Mattias

    2016-02-01

    Sequencing-based molecular characterization of tumors provides information required for individualized cancer treatment. There are well-defined molecular subtypes of breast cancer that provide improved prognostication compared to routine biomarkers. However, molecular subtyping is not yet implemented in routine breast cancer care. Clinical translation is dependent on subtype prediction models providing high sensitivity and specificity. In this study we evaluate sample size and RNA-sequencing read requirements for breast cancer subtyping to facilitate rational design of translational studies. We applied subsampling to ascertain the effect of training sample size and the number of RNA sequencing reads on classification accuracy of molecular subtype and routine biomarker prediction models (unsupervised and supervised). Subtype classification accuracy improved with increasing sample size up to N = 750 (accuracy = 0.93), although with a modest improvement beyond N = 350 (accuracy = 0.92). Prediction of routine biomarkers achieved accuracy of 0.94 (ER) and 0.92 (Her2) at N = 200. Subtype classification improved with RNA-sequencing library size up to 5 million reads. Development of molecular subtyping models for cancer diagnostics requires well-designed studies. Sample size and the number of RNA sequencing reads directly influence accuracy of molecular subtyping. Results in this study provide key information for rational design of translational studies aiming to bring sequencing-based diagnostics to the clinic.

  20. Diagnostic value of ultrasonography in evaluation and management ...

    African Journals Online (AJOL)

    Results: Common causes of acute abdominal emergencies in pediatric patients as noted on ultrasonography included nonspecifi c pain (28%), abdominal abscess (21%), acute appendicitis (7%) and intussusception (7%). Ultrasonography was diagnostic in 45.2% cases and supportive in 12.3% of the cases. As for as the fi ...

  1. Theoretical evaluation of measurement uncertainties of two-color pyrometry applied to optical diagnostics

    International Nuclear Information System (INIS)

    Fu Tairan; Cheng Xiaofang; Yang Zangjian

    2008-01-01

    We present a theoretical analysis of two-color pyrometry applied to optical diagnostics. A two-color pyrometer built with a single CCD is advantageous due to the simple system design. We evaluate the possibility and degree of ill-conditionness on the basis of measurement uncertainties for different measurement approaches of this two-color system. We classify measurement approaches. The corresponding ill-conditionness criterion is established. The greater the criterion value is, the worse the ill-conditioned degree of solution is. So, the optimum choice of measurement approach for the two-color system is achieved through intercomparison of the criterion values. Numerical examples are also given to illustrate this point. The theoretical analysis not only provides an effective way of evaluating different measurement approaches, but also may help us to better understand the influences that determine the choices between wavelength/waveband measurements and calibration/noncalibration modes for temperature and soot distribution

  2. Improved PV system reliability results from surge evaluations at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Russell H. Bonn; Sigifredo Gonzalez

    2000-01-01

    Electrical surges on ac and dc inverter power wiring and diagnostic cables have the potential to shorten the lifetime of power electronics. These surges may be caused by either nearby lightning or capacitor switching transients. This paper contains a description of ongoing surge evaluations of PV power electronics and surge mitigation hardware at Sandia

  3. Evaluation of the research diagnostic criteria for temporomandibular disorders for the recognition of an anterior disc displacement with reduction

    NARCIS (Netherlands)

    Naeije, M.; Kalaykova, S.; Visscher, C.M.; Lobbezoo, F.

    2009-01-01

    The aim of this Focus Article is to review critically the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) for the recognition of an anterior disc displacement with reduction (ADDR) in the temporomandibular joint (TMJ). This evaluation is based upon the experience gained

  4. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  5. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  6. Evaluation and proposal of improvement for the measurement system in ATLAS

    International Nuclear Information System (INIS)

    Cho, Dong Woo; Kim, Jong Rok; Park, Jun Kwon

    2007-03-01

    The project independently evaluated the validities and reliability of measurement system in ATLAS, then proposed plans to improve the measurement system from evaluated results. For this objectives, we evaluated the design, technical backgrounds, verifying data of measurement system in ATLAS. From this evaluation, we proposed plans for improvement on parts which need improvement

  7. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  8. Evidence of the preferential use of disease prototypes over case exemplars among early year one medical students prior to and following diagnostic training.

    Science.gov (United States)

    Papa, Frank J; Li, Feiming

    2015-12-01

    Two core dual processing theory (DPT) System I constructs (Exemplars and Prototypes) were used to: 1) formulate a training exercise designed to improve diagnostic performance in year one medical students, and 2) explore whether any observed performance improvements were associated with preferential use of exemplars or prototypes. With IRB approval, 117 year one medical students participated in an acute chest pain diagnostic training exercise. A pre- and post-training test containing the same 27 case vignettes was used to determine if the subjects' diagnostic performance improved via training in both exemplars and prototypes. Exemplar and Prototype theory was also used to generate a unique typicality estimate for each case vignette. Because these estimates produce different performance predictions, differences in the subjects' observed performance would make it possible to infer whether subjects were preferentially using Exemplars or Prototypes. Pre- vs. post-training comparison revealed a significant performance improvement; t=14.04, pmid typical vignettes: t=4.94, pleast typical: t=5.16, pmid typical: t=2.94, pleast typical: t=6.64, ptheory than Exemplar theory. DPT is useful in designing and evaluating the utility of new approaches to diagnostic training, and, investigating the cognitive factors driving diagnostic capabilities among early medical students.

  9. Assessing Autism in Adults: An Evaluation of the Developmental, Dimensional and Diagnostic Interview-Adult Version (3Di-Adult)

    Science.gov (United States)

    Mandy, William; Clarke, Kiri; McKenner, Michele; Strydom, Andre; Crabtree, Jason; Lai, Meng-Chuan; Allison, Carrie; Baron-Cohen, Simon; Skuse, David

    2018-01-01

    We developed a brief, informant-report interview for assessing autism spectrum conditions (ASC) in adults, called the Developmental, Dimensional and Diagnostic Interview-Adult Version (3Di-Adult); and completed a preliminary evaluation. Informant reports were collected for participants with ASC (n = 39), a non-clinical comparison group (n = 29)…

  10. Diagnostic accuracy of postmortem imaging vs autopsy-A systematic review.

    Science.gov (United States)

    Eriksson, Anders; Gustafsson, Torfinn; Höistad, Malin; Hultcrantz, Monica; Jacobson, Stella; Mejare, Ingegerd; Persson, Anders

    2017-04-01

    Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity - in populations, techniques, analyses and reporting - of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem imaging and its usefulness in conjunction with, or as an alternative to autopsy. To correctly determine the usefulness of postmortem imaging, future studies need improved planning, improved methodological quality and larger materials, preferentially obtained from multi-center studies. Copyright © 2016. Published by Elsevier B.V.

  11. Equipment for radiation diagnostics

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.

    1976-01-01

    The invention relates to an improvement of the line type of the plotter in an X-ray diagnostics apparatus enabling the production of distinguishable recordings by means of a single plot type. The construction is described explicitly. (UWI) [de

  12. Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆

    Science.gov (United States)

    Tang, Liansheng; Du, Pang; Wu, Chengqing

    2012-01-01

    Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484

  13. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing.

    Science.gov (United States)

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-02-01

    A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R 2 ), using R 2 as the primary metric of assay agreement. However, the use of R 2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Quality of reporting of diagnostic accuracy studies

    NARCIS (Netherlands)

    Smidt, N.; Rutjes, A.W.; Windt - Mens, van der D.A.W.M.; Ostelo, R.W.J.G.; Reitsma, J.B.; Bouter, L.M.; Vet, de H.C.W.

    2005-01-01

    PURPOSE: To evaluate quality of reporting in diagnostic accuracy articles published in 2000 in journals with impact factor of at least 4 by using items of Standards for Reporting of Diagnostic Accuracy (STARD) statement published later in 2003. MATERIALS AND METHODS: English-language articles on

  15. Nonphysician Care Providers Can Help to Increase Detection of Cognitive Impairment and Encourage Diagnostic Evaluation for Dementia in Community and Residential Care Settings.

    Science.gov (United States)

    Maslow, Katie; Fortinsky, Richard H

    2018-01-18

    In the United States, at least half of older adults living with dementia do not have a diagnosis. Their cognitive impairment may not have been detected, and some older adults whose physician recommends that they obtain a diagnostic evaluation do not follow through on the recommendation. Initiatives to increase detection of cognitive impairment and diagnosis of dementia have focused primarily on physician practices and public information programs to raise awareness about the importance of detection and diagnosis. Nonphysician care providers who work with older adults in community and residential care settings, such as aging network agencies, public health agencies, senior housing, assisted living, and nursing homes, interact frequently with older adults who have cognitive impairment but have not had a diagnostic evaluation. These care providers may be aware of signs of cognitive impairment and older adults' concerns about their cognition that have not been expressed to their physician. Within their scope of practice and training, nonphysician care providers can help to increase detection of cognitive impairment and encourage older adults with cognitive impairment to obtain a diagnostic evaluation to determine the cause of the condition. This article provides seven practice recommendations intended to increase involvement of nonphysician care providers in detecting cognitive impairment and encouraging older adults to obtain a diagnostic evaluation. The Kickstart-Assess-Evaluate-Refer (KAER) framework for physician practice in detection and diagnosis of dementia is used to identify ways to coordinate physician and nonphysician efforts and thereby increase the proportion of older adults living with dementia who have a diagnosis. © The Author(s) 2018. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Diagnostics and performance evaluation of multikilohertz capacitors

    International Nuclear Information System (INIS)

    McDuff, G.; Nunnally, W.C.; Rust, K.; Sarjeant, J.

    1980-01-01

    The observed performance of nanofarad polypropylene-silicone oil, mica paper, and polytetrafluoroethylene-silicone oil capacitors discharged in a 100-ns, 1-kA pulse with a pulse repetition frequency of 1 kHz is presented. The test facility circuit, diagnostic parameters, and the preliminary test schedule are outlined as a basis for discussion of the observed failure locations and proposed failure mechanisms. Most of the test data and discussion presented involves the polypropylene-silicone oil units

  17. Newer diagnostic approaches to intestinal protozoa.

    Science.gov (United States)

    van Lieshout, Lisette; Verweij, Jaco J

    2010-10-01

    To update the reader on the latest developments in the laboratory diagnosis of intestinal protozoa. Correct identification of a diarrhoea causing pathogens is essential for the choice of treatment in an individual patient as well as to map the aetiology of diarrhoea in a variety of patient populations. Classical diagnosis of diarrhoea causing protozoa by microscopic examination of a stool sample lacks both sensitivity and specificity. Alternative diagnostic platforms are discussed. Recent literature on the diagnosis of intestinal protozoa has focused mainly on nucleic acid-based assays, in particular the specific detection of parasite DNA in stool samples using real-time PCR. In addition, the trend has been moving from single pathogen detection to a multiplex approach, allowing simultaneous identification of multiple parasites. Different combinations of targets can be used within a routine diagnostic setting, depending on the patient population, such as children, immunocompromised individuals and those who have been travelling to tropical regions. Large-scale monitoring and evaluation of control strategies become feasible due to automation and high-throughput facilities. Improved technology also has become available for differentiating protozoa subspecies, which facilitates outbreak investigations and extensive research in molecular epidemiology.

  18. Diagnostic value of the evaluation of the glycogen content in muscle diseases by carbon 13 nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Jehenson, P.; Syrota, A.; Labrune, P.; Odievre, M.; Fardeau, M.

    1995-01-01

    We have developed a method for the evaluation of the muscle glycogen content by natural abundance C13 NMR and we here evaluate its diagnostic value on a large number of muscle diseases (20 glycogenoses and 42 other myopathies) and 8 normal subjects. The results show high values of the glycogen/creatine ratio in muscle glycogenoses, with no overlap with other diseased or normal subjects. This evaluation of the muscle glycogen content, which is performed at rest and thus easily applicable, in particular for children, is thus very sensitive and specific for the diagnosis of muscle glycogenosis. (authors). 9 refs

  19. Progress in diagnostics of the COMPASS tokamak

    Science.gov (United States)

    Weinzettl, V.; Adamek, J.; Berta, M.; Bilkova, P.; Bogar, O.; Bohm, P.; Cavalier, J.; Dejarnac, R.; Dimitrova, M.; Ficker, O.; Fridrich, D.; Grover, O.; Hacek, P.; Havlicek, J.; Havranek, A.; Horacek, J.; Hron, M.; Imrisek, M.; Komm, M.; Kovarik, K.; Krbec, J.; Markovic, T.; Matveeva, E.; Mitosinkova, K.; Mlynar, J.; Naydenkova, D.; Panek, R.; Paprok, R.; Peterka, M.; Podolnik, A.; Seidl, J.; Sos, M.; Stockel, J.; Tomes, M.; Varavin, M.; Varju, J.; Vlainic, M.; Vondracek, P.; Zajac, J.; Zacek, F.; Stano, M.; Anda, G.; Dunai, D.; Krizsanoczi, T.; Refy, D.; Zoletnik, S.; Silva, A.; Gomes, R.; Pereira, T.; Popov, Tsv.; Sarychev, D.; Ermak, G. P.; Zebrowski, J.; Jakubowski, M.; Rabinski, M.; Malinowski, K.; Nanobashvili, S.; Spolaore, M.; Vianello, N.; Gauthier, E.; Gunn, J. P.; Devitre, A.

    2017-12-01

    The COMPASS tokamak at IPP Prague is a small-size device with an ITER-relevant plasma geometry and operating in both the Ohmic as well as neutral beam assisted H-modes since 2012. A basic set of diagnostics installed at the beginning of the COMPASS operation has been gradually broadened in type of diagnostics, extended in number of detectors and collected channels and improved by an increased data acquisition speed. In recent years, a significant progress in diagnostic development has been motivated by the improved COMPASS plasma performance and broadening of its scientific programme (L-H transition and pedestal scaling studies, magnetic perturbations, runaway electron control and mitigation, plasma-surface interaction and corresponding heat fluxes, Alfvenic and edge localized mode observations, disruptions, etc.). In this contribution, we describe major upgrades of a broad spectrum of the COMPASS diagnostics and discuss their potential for physical studies. In particular, scrape-off layer plasma diagnostics will be represented by a new concept for microsecond electron temperature and heat flux measurements - we introduce a new set of divertor Langmuir and ball-pen probe arrays, newly constructed probe heads for reciprocating manipulators as well as several types of standalone probes. Among optical tools, an upgraded high-resolution edge Thomson scattering diagnostic for pedestal studies and a set of new visible light and infrared (plasma-surface interaction investigations) cameras will be described. Particle and beam diagnostics will be covered by a neutral particle analyzer, diagnostics on a lithium beam, Cherenkov detectors (for a direct detection of runaway electrons) and neutron detectors. We also present new modifications of the microwave reflectometer for fast edge density profile measurements.

  20. Diagnostic Management of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dabizzi, Emanuele [Division of Gastroenterology and Hepatology, Mayo Clinic Florida, 4500 San Pablo Road, Jacksonville, Florida 32224 (United States); Assef, Mauricio Saab [Faculdade de Ciências Médicas da Santa Casa de São Paulo, Rua Dr. Cesário Motta Jr. #61 Cep: 01221-020, São Paulo (Brazil); Raimondo, Massimo, E-mail: raimondo.massimo@mayo.edu [Division of Gastroenterology and Hepatology, Mayo Clinic Florida, 4500 San Pablo Road, Jacksonville, Florida 32224 (United States)

    2011-01-31

    Pancreatic cancer is one of the most deadly solid tumors, with an overall 5-year survival rate of less than 5%. Due to a non-specific clinical presentation, it is often diagnosed at an advanced stage and is rarely amenable for curative treatment. Therefore early diagnosis and appropriate staging are still essential to define the best care and to improve patient survival. Several imaging modalities are currently available for the evaluation of pancreatic cancer. This review focuses on different techniques and discusses the diagnostic management of patients with pancreatic cancer. This review was conducted utilizing Pubmed and was limited to papers published within the last 5 years. The search key words pancreatic cancer, pancreatic adenocarcinoma, pancreatic tumors, diagnosis, radiology, imaging, nuclear imaging, endoscopy, endoscopic ultrasound and biochemical markers were used.

  1. Diagnostic Management of Pancreatic Cancer

    International Nuclear Information System (INIS)

    Dabizzi, Emanuele; Assef, Mauricio Saab; Raimondo, Massimo

    2011-01-01

    Pancreatic cancer is one of the most deadly solid tumors, with an overall 5-year survival rate of less than 5%. Due to a non-specific clinical presentation, it is often diagnosed at an advanced stage and is rarely amenable for curative treatment. Therefore early diagnosis and appropriate staging are still essential to define the best care and to improve patient survival. Several imaging modalities are currently available for the evaluation of pancreatic cancer. This review focuses on different techniques and discusses the diagnostic management of patients with pancreatic cancer. This review was conducted utilizing Pubmed and was limited to papers published within the last 5 years. The search key words pancreatic cancer, pancreatic adenocarcinoma, pancreatic tumors, diagnosis, radiology, imaging, nuclear imaging, endoscopy, endoscopic ultrasound and biochemical markers were used

  2. Outpatient diagnostic of bladder tumours in flexible cystoscopes

    DEFF Research Database (Denmark)

    Hermann, Gregers G; Mogensen, Karin; Toft, Birgitte Grønkær

    2012-01-01

    The aim of this study was to evaluate photodynamic diagnosis (PDD) in flexible cystoscopes and the diagnostic quality of biopsies for diagnosis of non-muscle-invasive bladder cancer in the outpatients department (OPD).......The aim of this study was to evaluate photodynamic diagnosis (PDD) in flexible cystoscopes and the diagnostic quality of biopsies for diagnosis of non-muscle-invasive bladder cancer in the outpatients department (OPD)....

  3. Efficient strategies to find diagnostic test accuracy studies in kidney journals.

    Science.gov (United States)

    Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C

    2015-08-01

    Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.

  4. Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Notohamiprodjo, S.; Stahl, R.; Braunagel, M.; Kazmierczak, P.M.; Thierfelder, K.M.; Treitl, K.M.; Wirth, S. [University Hospital of Munich, LMU Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, M. [University Hospital Tuebingen, Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-08-15

    To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. (orig.)

  5. Electrophysiological evidence for colour effects on the naming of colour diagnostic and noncolour diagnostic objects

    OpenAIRE

    Bramão, I.; Francisco, A.; Inácio , F.; Faísca, L.; Reis, A.; Petersson, K.

    2012-01-01

    In this study, we investigated the level of visual processing at which surface colour information improves the naming of colour diagnostic and noncolour diagnostic objects. Continuous electroencephalograms were recorded while participants performed a visual object naming task in which coloured and black-and-white versions of both types of objects were presented. The black-and-white and the colour presentations were compared in two groups of event-related potentials (ERPs): (1) The P1 and N1 c...

  6. Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.

    Science.gov (United States)

    Rao, Harsha L; Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-03-01

    To evaluate the effect of typical scan score (TSS), when within the acceptable limits, on the diagnostic performance of retinal nerve fibre layer (RNFL) parameters with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in glaucoma. In a cross-sectional study, 203 eyes of 160 glaucoma patients and 140 eyes of 104 control subjects underwent RNFL imaging with the ECC protocol of SLP. TSS was used to quantify atypical birefringence pattern (ABP) images. Influence of TSS on the diagnostic ability of SLP parameters was evaluated by receiver operating characteristic (ROC) regression models after adjusting for the effect of disease severity [based on mean deviation (MD)] on standard automated perimetry). Diagnostic abilities of all RNFL parameters of SLP increased when the TSS values were higher. This effect was statistically significant for TSNIT (coefficient: 0.08, p<0.001) and inferior average parameters (coefficient: 0.06, p=0.002) but not for nerve fibre indicator (NFI, coefficient: 0.03, p=0.21). In early glaucoma (MD of -5 dB), predicted area under ROC curve (AUC) for TSNIT average parameter improved from 0.642 at a TSS of 90 to 0.845 at a TSS of 100. In advanced glaucoma (MD of -15 dB), AUC for TSNIT average improved from 0.832 at a TSS of 90 to 0.947 at 100. Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits. Diagnostic ability of NFI was unaffected by TSS values. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Dyspnea in the ambulance - etiology, mortality, and point-of-care diagnostics

    DEFF Research Database (Denmark)

    Bøtker, Morten Thingemann

    2016-01-01

    dyspnea in the ambulance requires identification of high-risk groups and early correct treatment. Bringing forward simplified versions of advanced diagnostic modalities known from the hospital as point-of-care diagnostics already in the ambulance may aid the discrimination of underlying conditions causing......, we included all patients dialing the emergency number (1-1-2) due to a medical emergency in three of five Danish regions. For identification of highrisk patients and evaluation of electrocardiogram-based triage, we compared short-term mortality between patients included in the first study based...... that are highly prioritized in emergency medical services – including chest pain and trauma. Whether this increased mortality can be ascribed to an older age and comorbidity among patients suffering dyspnea, or if modifiable risk factors are also present, is unsettled. Improving outcome for patients suffering...

  8. Diagnostic efficacy of optimised evaluation of planar MIBI myocardium perfusion scintigraphy: a probabilistic approach

    International Nuclear Information System (INIS)

    Kusmierek, J.; Plachcinska, A.

    1999-01-01

    Background: The Bayesian (probabilistic) approach to the results of a diagnostic test appears to be more informative than an interpretation of results in binary terms (having disease or not). The aim of our study was the analysis of the effect of an optimised evaluation of myocardium perfusion scintigrams on the probability of CAD in individual patients. Methods: 197 patients (132 males and 65 females) suspected of CAD, with no history of myocardial infarction were examined. Scintigraphic images were evaluated applying two methods of analysis: visual (semiquantitative) and quantitative, and the combination of both. The sensitivity and specificity of both methods (and their combination) in the detection of CAD were determined and optimal methods of scintigram evaluation, separately for males and females, were selected. All patients were subjected to coronary angiography. The pre-test probability of CAD was assessed according to Diamond (1) and the post-test probability was evaluated in accordance with Bayes's theorem. Patients were divided, according to a pre-test probability of CAD, into 3 groups: with low, medium and high probability of the disease. The same subdivision was made in relation to post-test probability of CAD. The numbers of patients in respective subgroups, before and after the test, were compared. Moreover, in order to test the reliability of post-test probability, its values were compared with real percentages of CAD occurrence among the patients under study, as demonstrated by the angiography. Results: The combination of visual and quantitative methods was accepted as the optimal method of male scintigram evaluation (with sensitivity and specificity equalling 95% and 82%, respectively) and a sole quantitative analysis as the optimal method of female scintigram evaluation (sensitivity and specificity amounted to 81% and 84%, respectively). In the subgroup of males the percentage of individuals with medium pre-test CAD probability equalled 52 and

  9. Diagnostic accuracy of physical examination for anterior knee instability: a systematic review.

    Science.gov (United States)

    Leblanc, Marie-Claude; Kowalczuk, Marcin; Andruszkiewicz, Nicole; Simunovic, Nicole; Farrokhyar, Forough; Turnbull, Travis Lee; Debski, Richard E; Ayeni, Olufemi R

    2015-10-01

    Determining diagnostic accuracy of Lachman, pivot shift and anterior drawer tests versus gold standard diagnosis (magnetic resonance imaging or arthroscopy) for anterior cruciate ligament (ACL) insufficiency cases. Secondarily, evaluating effects of: chronicity, partial rupture, awake versus anaesthetized evaluation. Searching MEDLINE, EMBASE and PubMed identified studies on diagnostic accuracy for ACL insufficiency. Studies identification and data extraction were performed in duplicate. Quality assessment used QUADAS tool, and statistical analyses were completed for pooled sensitivity and specificity. Eight studies were included. Given insufficient data, pooled analysis was only possible for sensitivity on Lachman and pivot shift test. During awake evaluation, sensitivity for the Lachman test was 89 % (95 % CI 0.76, 0.98) for all rupture types, 96 % (95 % CI 0.90, 1.00) for complete ruptures and 68 % (95 % CI 0.25, 0.98) for partial ruptures. For pivot shift in awake evaluation, results were 79 % (95 % CI 0.63, 0.91) for all rupture types, 86 % (95 % CI 0.68, 0.99) for complete ruptures and 67 % (95 % CI 0.47, 0.83) for partial ruptures. Decreased sensitivity of Lachman and pivot shift tests for partial rupture cases and for awake patients raised suspicions regarding the accuracy of these tests for diagnosis of ACL insufficiency. This may lead to further research aiming to improve the understanding of the true accuracy of these physical diagnostic tests and increase the reliability of clinical investigation for this pathology. IV.

  10. Diagnostic Error in Stroke-Reasons and Proposed Solutions.

    Science.gov (United States)

    Bakradze, Ekaterina; Liberman, Ava L

    2018-02-13

    We discuss the frequency of stroke misdiagnosis and identify subgroups of stroke at high risk for specific diagnostic errors. In addition, we review common reasons for misdiagnosis and propose solutions to decrease error. According to a recent report by the National Academy of Medicine, most people in the USA are likely to experience a diagnostic error during their lifetimes. Nearly half of such errors result in serious disability and death. Stroke misdiagnosis is a major health care concern, with initial misdiagnosis estimated to occur in 9% of all stroke patients in the emergency setting. Under- or missed diagnosis (false negative) of stroke can result in adverse patient outcomes due to the preclusion of acute treatments and failure to initiate secondary prevention strategies. On the other hand, the overdiagnosis of stroke can result in inappropriate treatment, delayed identification of actual underlying disease, and increased health care costs. Young patients, women, minorities, and patients presenting with non-specific, transient, or posterior circulation stroke symptoms are at increased risk of misdiagnosis. Strategies to decrease diagnostic error in stroke have largely focused on early stroke detection via bedside examination strategies and a clinical decision rules. Targeted interventions to improve the diagnostic accuracy of stroke diagnosis among high-risk groups as well as symptom-specific clinical decision supports are needed. There are a number of open questions in the study of stroke misdiagnosis. To improve patient outcomes, existing strategies to improve stroke diagnostic accuracy should be more broadly adopted and novel interventions devised and tested to reduce diagnostic errors.

  11. Improving recognition of late life anxiety disorders in Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition: observations and recommendations of the Advisory Committee to the Lifespan Disorders Work Group

    NARCIS (Netherlands)

    Mohlman, J.; Bryant, C.; Lenze, E.J.; Stanley, M.A.; Gum, A.; Flint, A.; Beekman, A.T.F.; Wetherell, J.L.; Thorp, S.R.; Craske, MG

    2012-01-01

    Background Recognition of the significance of anxiety disorders in older adults is growing. The revision of the Diagnostic and Statistical Manual of Mental Disorders (DSM) provides a timely opportunity to consider potential improvements to diagnostic criteria for psychiatric disorders for use with

  12. Skeletal diseases. Diagnostic clinical radiology and differential diagnostics. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1997-01-01

    The book focuses on the diagnostic evaluation of idiopathic diseases of the skeleton and bone joints, also including the fundamental healing processes of bone fractures, particularly of stress-induced and pathologic fractures. Ample space has been given to the description and imaging of the course of diseases under treatment by up-to-date therapies, as e.g. for ostitis deformans Paget's disease, or skeletal metastases. This second edition of the book incorporates the progress achieved over the last five years in skeletal diagnostics. The advances in this field have been resulting from basic research work, for instance in molecular biology, or from a variety of completed studies relating to clinical medicine, laboratory chemistry, histopathology and radiology of skeletal diseases, and from experience obtained with the diagnostic radiology methods and techniques, with the potentials and constraints of magnetic resonance imaging (MRI) today being more critically assessed than five years ago. MRI is a modality currently meeting with interest in the context of search for additional diagnostic information, new definition of complete pictures of diseases, or false or overinterpretation of diagnostic findings. (orig./MG). 431 figs [de

  13. The evaluation and impact of diagnostic tests

    International Nuclear Information System (INIS)

    Royal, H.D.; McNeil, B.J.

    1989-01-01

    The authors describe the usefulness of the techniques that are applied to study the role of tests and point out their limitations. In many instances, complex tasks must be oversimplified in order to use currently available analytic tools. Certain tools, such as decision analysis, are useful not only because they can provide insight regarding the most favorable diagnostic/therapeutic strategies but also because they can identify areas where present knowledge is inadequate and thereby help put priorities on areas of research

  14. The Utility of Diagnostic Laparoscopy in Post-Bariatric Surgery Patients with Chronic Abdominal Pain of Unknown Etiology.

    Science.gov (United States)

    Alsulaimy, Mohammad; Punchai, Suriya; Ali, Fouzeyah A; Kroh, Matthew; Schauer, Philip R; Brethauer, Stacy A; Aminian, Ali

    2017-08-01

    Chronic abdominal pain after bariatric surgery is associated with diagnostic and therapeutic challenges. The aim of this study was to evaluate the yield of laparoscopy as a diagnostic and therapeutic tool in post-bariatric surgery patients with chronic abdominal pain who had negative imaging and endoscopic studies. A retrospective analysis was performed on post-bariatric surgery patients who underwent laparoscopy for diagnosis and treatment of chronic abdominal pain at a single academic center. Only patients with both negative preoperative CT scan and upper endoscopy were included. Total of 35 post-bariatric surgery patients met the inclusion criteria, and all had history of Roux-en-Y gastric bypass. Twenty out of 35 patients (57%) had positive findings on diagnostic laparoscopy including presence of adhesions (n = 12), chronic cholecystitis (n = 4), mesenteric defect (n = 2), internal hernia (n = 1), and necrotic omentum (n = 1). Two patients developed post-operative complications including a pelvic abscess and an abdominal wall abscess. Overall, 15 patients (43%) had symptomatic improvement after laparoscopy; 14 of these patients had positive laparoscopic findings requiring intervention (70% of the patients with positive laparoscopy). Conversely, 20 (57%) patients required long-term medical treatment for management of chronic abdominal pain. Diagnostic laparoscopy, which is a safe procedure, can detect pathological findings in more than half of post-bariatric surgery patients with chronic abdominal pain of unknown etiology. About 40% of patients who undergo diagnostic laparoscopy and 70% of patients with positive findings on laparoscopy experience significant symptom improvement. Patients should be informed that diagnostic laparoscopy is associated with no symptom improvement in about half of cases.

  15. Diagnostic imaging capabilities of the Ocelot -Optical Coherence Tomography System, ex-vivo evaluation and clinical relevance

    International Nuclear Information System (INIS)

    Dohad, Suhail; Shao, John; Cawich, Ian; Kankaria, Manish; Desai, Arjun

    2015-01-01

    Optical coherence tomography (OCT) is a high-resolution sub-surface imaging modality using near-infrared light to provide accurate and high contrast intra-vascular images. This enables accurate assessment of diseased arteries before and after intravascular intervention. This study was designed to corroborate diagnostic imaging equivalence between the Ocelot and the Dragonfly OCT systems with regards to the intravascular features that are most important in clinical management of patients with atherosclerotic vascular disease. These intravascular features were then corroborated in vivo during treatment of peripheral arterial disease (PAD) pathology using the Ocelot catheter. In order to compare the diagnostic information obtained by Ocelot (Avinger Inc., Redwood City, CA) and Dragonfly (St. Jude Medical, Minneapolis, MN) OCT systems, we utilized ex-vivo preparations of arterial segments. Ocelot and Dragonfly catheters were inserted into identical cadaveric femoral peripheral arteries for image acquisition and interpretation. Three independent physician interpreters assessed the images to establish accuracy and sensitivity of the diagnostic information. Histologic evaluation of the corresponding arterial segments provided the gold standard for image interpretation. In vivo clinical images were obtained during therapeutic interventions that included crossing of peripheral chronic total occlusions (CTOs) using the Ocelot catheter. Strong concordance was demonstrated when matching image characteristics between both OCT systems and histology. The Dragonfly and Ocelot system’s vessel features were interpreted with high sensitivity (91.1–100 %) and specificity (86.7–100 %). Inter-observer concordance was documented with excellent correlation across all vessel features. The clinical benefit that the Ocelot OCT system provided was demonstrated by comparable procedural images acquired at the point of therapy. The study demonstrates equivalence of image acquisition and

  16. Diagnostic value of the 2011 International Federation for Cervical Pathology and Colposcopy Terminology in predicting cervical lesions

    Science.gov (United States)

    Zhang, Liqin; Yan, Ye; Han, Cha; Xue, Fengxia

    2018-01-01

    Objective To evaluate the diagnostic accuracy of the 2011 International Federation for Cervical Pathology and Colposcopy (IFCPC) colposcopic terminology. Methods The clinicopathological data of 2262 patients who underwent colposcopy from September 2012 to September 2016 were reviewed. The colposcopic findings, colposcopic impression, and cervical histopathology of the patients were analyzed. Correlations between variables were evaluated using cervical histopathology as the gold standard. Results Colposcopic diagnosis matched biopsy histopathology in 1482 patients (65.5%), and the weighted kappa strength of agreement was 0.480 (Pterminology can improve the diagnostic accuracy for all lesion severities. The categorization of major changes and minor changes is appropriate. However, colposcopic diagnosis remains unsatisfactory. Poor reproducibility of type 2 transformation zone and the significance of leukoplakia require further study. PMID:29507681

  17. Aircraft gas turbine engine vibration diagnostics

    Directory of Open Access Journals (Sweden)

    Stanislav Fábry

    2017-11-01

    Full Text Available In the Czech and Slovak aviation are in service elderly aircrafts, usually produced in former Soviet Union. Their power units can be operated in more efficient way, in case of using additional diagnostic methods that allow evaluating their health. Vibration diagnostics is one of the methods indicating changes of rotational machine dynamics. Ground tests of aircraft gas turbine engines allow vibration recording and analysis. Results contribute to airworthiness evaluation and making corrections, if needed. Vibration sensors distribution, signal recording and processing are introduced in a paper. Recorded and re-calculated vibration parameters are used in role of health indicators.

  18. Experienced physicians benefit from analyzing initial diagnostic hypotheses

    Directory of Open Access Journals (Sweden)

    Adam Bass

    2013-03-01

    Full Text Available Background: Most incorrect diagnoses involve at least one cognitive error, of which premature closure is the most prevalent. While metacognitive strategies can mitigate premature closure in inexperienced learners, these are rarely studied in experienced physicians. Our objective here was to evaluate the effect of analytic information processing on diagnostic performance of nephrologists and nephrology residents. Methods: We asked nine nephrologists and six nephrology residents at the University of Calgary and Glasgow University to diagnose ten nephrology cases. We provided presenting features along with contextual information, after which we asked for an initial diagnosis. We then primed participants to use either hypothetico-deductive reasoning or scheme-inductive reasoning to analyze the remaining case data and generate a final diagnosis. Results: After analyzing initial hypotheses, both nephrologists and residents improved the accuracy of final diagnoses (31.1% vs. 65.6%, p < 0.001, and 40.0% vs. 70.0%, p < 0.001, respectively. We found a significant interaction between experience and analytic processing strategy (p = 0.002: nephrology residents had significantly increased odds of diagnostic success when using scheme-inductive reasoning (odds ratio [95% confidence interval] 5.69 [1.59, 20.33], p = 0.007, whereas the performance of experienced nephrologists did not differ between strategies (odds ratio 0.57 [0.23, 1.39], p = 0.2. Discussion: Experienced nephrologists and nephrology residents can improve their performance by analyzing initial diagnostic hypotheses. The explanation of the interaction between experience and the effect of different reasoning strategies is unclear, but may relate to preferences in reasoning strategy, or the changes in knowledge structure with experience.

  19. Does ultrasound contrast agent improve the diagnostic value of colour and power Doppler sonography in superficial lymph node enlargement?

    International Nuclear Information System (INIS)

    Schulte-Altedorneburg, Gernot; Demharter, Johannes; Linne, Renate; Droste, Dirk W.; Bohndorf, Klaus; Buecklein, Wolfgang

    2003-01-01

    Objective: to analyse whether ultrasound contrast agent (UCA) improves the diagnostic accuracy to differentiate between benign and malignant superficial lymph node enlargement by using colour-coded duplex sonography (CCDS) and power Doppler (PD). Methods: 32 patients with suspected malignant superficial lymph node enlargement prospectively underwent standardised ultrasound examinations using B-mode sonography and native and contrast-enhanced CCDS and PD immediately before biopsy. Solbiati-Index (longitudinal-transverse diameter ratio) and intranodal flow patterns by using different vascularisation types were assessed. Histological and sonographical findings were correlated. Results: 27 malignant and 5 benign lymph nodes were found. Solbiati-Index was lower in malignant lymph nodes than in benign nodes (mean 1.5 vs. 2.4, P<0.045). More intranodal flow patterns could be detected after UCA (53 vs. 43) but the number of correctly identified malignant nodes decreased after UCA (26 vs. 24) and the number of correctly identified benign nodes remained constant compared with native CCDS and PD. In 31% of the colour-mode studies, PD was considered to visualise more clearly intranodal vascular flow patterns than CCDS. Conclusion: despite depicting more intranodal vascular patterns, the use of an ultrasound contrast agent seems not to improve the diagnostic value of CCDS and PD compared with native colour-mode studies in superficial lymph node enlargement

  20. Newborn Congenital Cytomegalovirus Screening Based on Clinical Manifestations and Evaluation of DNA-based Assays for In Vitro Diagnostics.

    Science.gov (United States)

    Fujii, Tomoyuki; Oka, Akira; Morioka, Ichiro; Moriuchi, Hiroyuki; Koyano, Shin; Yamada, Hideto; Saito, Shigeru; Sameshima, Hiroshi; Nagamatsu, Takeshi; Tsuchida, Shinya; Inoue, Naoki

    2017-10-01

    To establish a strategy for congenital cytomegalovirus (cCMV) screening and to establish confirmatory assays approved as in vitro diagnostics by the regulatory authorities, we evaluated the clinical risks and performance of diagnostic assays developed by commercial companies, since cCMV infection has significant clinical consequences. Newborns with clinical manifestations considered to be consequences of cCMV infection (n = 575) were screened for the presence of cytomegalovirus (CMV) DNA in urine specimens collected onto filter paper placed in their diapers using the polymerase chain reaction-based assay reported previously. Liquid urine specimens were obtained from all of 20 CMV-positive newborns and 107 of the CMV-negative newborns identified in the screening. We used these 127 specimens, as well as 12 from cCMV cases identified in a previous study and 41 from healthy newborns, to compare the performance of 2 commercial assays and 1 in-house assay. The risk-based screening allowed the identification of cCMV cases at least 10-fold more efficiently than our previous universal screening, although there appears to be a limit to the identification of asymptomatically infected newborns. Although CMV-specific IgM during pregnancy was found frequently in mothers of cCMV newborns, CMV-IgM alone is not an effective diagnostic marker. The urine-filter-based assay and the 3 diagnostic assays yielded identical results. Although risk-based and universal newborn screening strategies for cCMV infection each have their respective advantages and disadvantages, urine-filter-based assay followed by confirmatory in vitro diagnostics assays is able to identify cCMV cases efficiently.

  1. Current status and future perspectives on molecular and serological methods in diagnostic mycology.

    Science.gov (United States)

    Lau, Anna; Chen, Sharon; Sleiman, Sue; Sorrell, Tania

    2009-11-01

    Invasive fungal infections are an important cause of infectious morbidity. Nonculture-based methods are increasingly used for rapid, accurate diagnosis to improve patient outcomes. New and existing DNA amplification platforms have high sensitivity and specificity for direct detection and identification of fungi in clinical specimens. Since laboratories are increasingly reliant on DNA sequencing for fungal identification, measures to improve sequence interpretation should support validation of reference isolates and quality control in public gene repositories. Novel technologies (e.g., isothermal and PNA FISH methods), platforms enabling high-throughput analyses (e.g., DNA microarrays and Luminex xMAP) and/or commercial PCR assays warrant further evaluation for routine diagnostic use. Notwithstanding the advantages of molecular tests, serological assays remain clinically useful for patient management. The serum Aspergillus galactomannan test has been incorporated into diagnostic algorithms of invasive aspergillosis. Both the galactomannan and the serum beta-D-glucan test have value for diagnosing infection and monitoring therapeutic response.

  2. Advanced diagnostic graphics

    International Nuclear Information System (INIS)

    Bray, M.A.; Petersen, R.J.; Clark, M.T.; Gertman, D.I.

    1981-01-01

    This paper reports US NRC-sponsored research at the Idaho National Engineering Laboratory (INEL) involving evaluation of computer-based diagnostic graphics. The specific targets of current evaluations are multivariate data display formats which may be used in Safety Parameter Display Systems (SPDS) being developed for nuclear power plant control rooms. The purpose of the work is to provide a basis for NRC action in regulating licensee SPDSs or later computer/cathode ray tube (CRT) applications in nuclear control rooms

  3. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    Science.gov (United States)

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  4. Diagnostic accuracy of imaging modalities for internal derangements of temporomandibular joint

    International Nuclear Information System (INIS)

    Kobayashi, Kaoru; Igarashi, Chinami; Yuasa, Masao; Imanaka, Masahiro; Kondoh, Toshirou

    1998-01-01

    The purpose of this study was to evaluate and review the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of imaging diagnosis for temporomandibular disorders. The role of diagnostic imaging is to detect and document specific anatomic abnormalities associated with the signs and symptoms in the temporomandibular joint. Magnetic resonance imaging (MR imaging) can accurately depict disc displacement and disc deformity. MR imaging is our first choice among the various imaging modalities for the patients with clinical signs and symptoms. However, it has been shown that intra-capsular adhesions and perforations of the disc and retrodiscal tissue are sometimes not detected by MR imaging. To improve the diagnostic technique for adhesions and perforations, double-contrast arthrotomography with fluoroscopy should be employed. The irregular surface of the eminences and the glenoid fossae shown by MR imaging and tomography are correlated with subchondral bone exposure by arthroscopy. Erosion of the condyles detected by MR imaging, tomography and rotational panoramic radiography is correlated with subchondral bone exposure detected by arthroscopy. (author). 69 refs

  5. Microfluidic point-of-care diagnostics for resource-poor environments

    Science.gov (United States)

    Laksanasopin, Tassaneewan; Chin, Curtis D.; Moore, Hannah; Wang, Jennifer; Cheung, Yuk Kee; Sia, Samuel K.

    2009-05-01

    Point-of-care (POC) diagnostics have tremendous potential to improve human health in remote and resource-poor settings. However, the design criteria for diagnostic tests appropriate in settings with limited infrastructure are unique and challenging. Here we present a custom optical reader which quantifies silver absorbance from heterogeneous immunoassays. The reader is simple and low-cost and suited for POC diagnostics.

  6. Scaling-Up the Functional Diagnostic Systems

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2008-01-01

    Functional diagnostic systems received a lot of attention in the last decade. They have proven their powerful for diagnosis the new faults of some complex systems. But, they still have some complexity in both the representation and reasoning about the large-scale systems. This paper introduces a new functional diagnostic system that can divide its small functions into main and auxiliary ones. This process enables the diagnostic system to scale -up the representation of the tested system and simplify the diagnostic mechanism tasks. Thus, it can improve both the representation and reasoning complexity. Also,it can decrease the required analysis, cost, and time. Proposed system can be applied for a wide area of the large-scale systems. It has been proven its acceptance to be applied practically for the Complex real-time systems

  7. Evaluation of Fibroblast Activation Protein-Alpha (FAP) as a Diagnostic Marker and Therapeutic Target in Prostate Cancer

    Science.gov (United States)

    2009-12-01

    low molecular weight recombinant human gelatin: development of a substitute for animal- derived gelatin with superior features, Protein Expr. Purif...by the honey - bee , could be modified to a form that was no longer hydro- lyzed by the native activator protease DPP4 but, instead, was hydrolyzed by...TITLE: Evaluation of Fibroblast Activation Protein -Alpha (FAP) as a Diagnostic Marker and Therapeutic Target in Prostate Cancer PRINCIPAL

  8. The IOM report on improving diagnosis: new concepts.

    Science.gov (United States)

    Graber, Mark L

    2015-12-01

    The IOM report 'Improving Diagnosis in Health Care' represents a major advance in summarizing the problem of diagnostic error. Three new concepts in the report will be helpful in future efforts to understand and improve the diagnostic process: a new definition of diagnostic error, a new framework for understanding the diagnostic process, and a new concept of the diagnostic 'team'. This paper highlights these new concepts and their relevance to improving diagnosis.

  9. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  10. Computer Vision Malaria Diagnostic Systems—Progress and Prospects

    Directory of Open Access Journals (Sweden)

    Joseph Joel Pollak

    2017-08-01

    Full Text Available Accurate malaria diagnosis is critical to prevent malaria fatalities, curb overuse of antimalarial drugs, and promote appropriate management of other causes of fever. While several diagnostic tests exist, the need for a rapid and highly accurate malaria assay remains. Microscopy and rapid diagnostic tests are the main diagnostic modalities available, yet they can demonstrate poor performance and accuracy. Automated microscopy platforms have the potential to significantly improve and standardize malaria diagnosis. Based on image recognition and machine learning algorithms, these systems maintain the benefits of light microscopy and provide improvements such as quicker scanning time, greater scanning area, and increased consistency brought by automation. While these applications have been in development for over a decade, recently several commercial platforms have emerged. In this review, we discuss the most advanced computer vision malaria diagnostic technologies and investigate several of their features which are central to field use. Additionally, we discuss the technological and policy barriers to implementing these technologies in low-resource settings world-wide.

  11. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  12. Enhanced NIF neutron activation diagnostics.

    Science.gov (United States)

    Yeamans, C B; Bleuel, D L; Bernstein, L A

    2012-10-01

    The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the (89)Zr/(89 m)Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

  13. Evaluation of the effectiveness of gonad protection in diagnostic radiology

    International Nuclear Information System (INIS)

    Kawaura, Chiyo; Aoyama, Takahiko; Koyama, Shuji

    2004-01-01

    In the present study we describes the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60). (author)

  14. [Evaluation of the effectiveness of gonad protection in diagnostic radiology].

    Science.gov (United States)

    Kawaura, Chiyo; Aoyama, Takahiko; Koyama, Shuji

    2004-01-01

    In the present study we describe the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60).

  15. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  16. Diagnostic information system dynamics in the evaluation of machine learning algorithms for the supervision of energy efficiency of district heating-supplied buildings

    International Nuclear Information System (INIS)

    Kiluk, Sebastian

    2017-01-01

    Highlights: • Energy efficiency classification sustainability benefits from knowledge prediction. • Diagnostic classification can be validated with its dynamics and current data. • Diagnostic classification dynamics provides novelty extraction for knowledge update. • Data mining comparison can be performed with knowledge dynamics and uncertainty. • Diagnostic information refinement benefits form comparing classifiers dynamics. - Abstract: Modern ways of exploring the diagnostic knowledge provided by data mining and machine learning raise some concern about the ways of evaluating the quality of output knowledge, usually represented by information systems. Especially in district heating, the stationarity of efficiency models, and thus the relevance of diagnostic classification system, cannot be ensured due to the impact of social, economic or technological changes, which are hard to identify or predict. Therefore, data mining and machine learning have become an attractive strategy for automatically and continuously absorbing such dynamics. This paper presents a new method of evaluation and comparison of diagnostic information systems gathered algorithmically in district heating efficiency supervision based on exploring the evolution of information system and analyzing its dynamic features. The process of data mining and knowledge discovery was applied to the data acquired from district heating substations’ energy meters to provide the automated discovery of diagnostic knowledge base necessary for the efficiency supervision of district heating-supplied buildings. The implemented algorithm consists of several steps of processing the billing data, including preparation, segmentation, aggregation and knowledge discovery stage, where classes of abstract models representing energy efficiency constitute an information system representing diagnostic knowledge about the energy efficiency of buildings favorably operating under similar climate conditions and

  17. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  18. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  19. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    2011-01-01

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  20. ITER diagnostics: Design choices and solutions

    International Nuclear Information System (INIS)

    Costley, A.E.; Sugie, T.; Vayakis, G.; Malaquias, A.; Walker, C.

    2003-01-01

    An extensive diagnostic system will be installed on ITER to provide the measurements necessary to control, evaluate and optimise the plasma performance and to study burning plasma physics. Because of the harsh environment, diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic implementation. In this paper, we describe the key problems encountered and give examples of the solutions that have been developed. A brief description of the scheme developed for integrating multiple systems into individual ports is also included. We conclude with an assessment of overall system performance. (author)

  1. ITER diagnostics ex-vessel engineering services

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, A.P., E-mail: arun.prakash@iter.org; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.; and others

    2013-10-15

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  2. ITER diagnostics ex-vessel engineering services

    International Nuclear Information System (INIS)

    Arumugam, A.P.; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.

    2013-01-01

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  3. Selective use of diagnostic laparoscopy in patients with suspected appendicitis

    NARCIS (Netherlands)

    van den Broek, W. T.; Bijnen, A. B.; van Eerten, P. V.; de Ruiter, P.; Gouma, D. J.

    2000-01-01

    BACKGROUND: Diagnostic laparoscopy has been introduced as a new diagnostic tool for patients with acute appendicitis. We performed diagnostic laparoscopy when the clinical diagnosis of appendicitis was in doubt. The aims of this study were to evaluate this strategy and to analyze the efficacy of

  4. Salpingoscopy: systematic use in diagnostic laparoscopy.

    Science.gov (United States)

    Marconi, G; Auge, L; Sojo, E; Young, E; Quintana, R

    1992-04-01

    To evaluate the importance of salpingoscopy together with laparoscopy in the diagnosis of tubal pathology. Salpingoscopy was performed as a complementary method in patients who were subjected to diagnostic laparoscopy. The relationship between the salpingoscopy and (1) the patient's previous history of tubal disease and (2) laparoscopic diagnoses was evaluated. Private patients referred to the Instituto de Fertilidad, Buenos Aires. Forty-two patients undergoing a diagnostic laparoscopy during the evaluation of their fertility or as a follow-up of previous therapy. Salpingoscopy was performed, using a colpomicrohysteroscope. We evaluated alterations in major and minor folds and their vascularization, the presence of microadhesions, and cellular nuclei dyed with methylene blue in the tubal lumen. Fifty percent of the patients who had no previous history of tubal disease presented with endosalpingeal alterations, and in 37% of the normal laparoscopies the salpinx had unilateral or bilateral salpingoscopic abnormalities. Salpingoscopy is a useful method to evaluate oviducts, before assuming their normality, and consideration of these women for assisted reproductive technology.

  5. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    International Nuclear Information System (INIS)

    Shelton, R; O'Brien, D; Nelson, J; Kamperschroer, J

    2007-01-01

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the deployed

  6. Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shelton, R; O' Brien, D; Nelson, J; Kamperschroer, J

    2007-05-07

    NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at other sites. To accommodate the growing number of target diagnostics, an Instrument-Based Controls hardware-software framework has been developed to facilitate development and ease integration into the NIF Integrated Computer Control System (ICCS). Individual WindowsXP PC controllers for each digitizer, power supply and camera (i.e., instruments) execute controls software unique to each instrument model. Each hardware-software controller manages a single instrument, in contrast to the complexity of combining all the controls software needed for a diagnostic into a single controller. Because of this simplification, controllers can be more easily tested on the actual hardware, evaluating all normal and off-normal conditions. Each target diagnostic is then supported by a number of instruments, each with its own hardware-software instrument-based controller. Advantages of the instrument-based control architecture and framework include reusability, testability, and improved reliability of the

  7. Shutdown dose rate contribution from diagnostics in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, M.S., E-mail: munseong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Pak, S.; An, Y.H.; Seon, C.R.; Lee, H.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Bertalot, L.; Krasilnikov, V. [ITER Organization, St Paul-lez-Durance (France); Zvonkov, A. [Agency ITER-RF, Moscow (Russian Federation)

    2016-11-01

    Highlights: • The Shutdown Dose Rate in the interspace of ITER upper port 18 was evaluated. • VUV spectrometer is the dominant contributor to the average SDR. • The existence and size of the blanket cooling pipes impacts significantly on SDR. - Abstract: D-T operation of ITER plasma will produce high-energy fusion neutrons those can activate materials around the place where human-access is necessary. The interspace of the diagnostic port is one of the area where human-access is necessary for the maintenance of diagnostic systems installed at the port, so it is important to evaluate a dose rate of the interspace area in order to comply with ALARA principle. The shutdown dose rate (SDR) in the interspace of ITER upper port 18 was evaluated by the Direct 1-Step (D1S) method using MCNP5 code. This port contains three diagnostics: Vacuum Ultra-Violet (VUV) Spectrometer, Neutron Activation System (NAS), and Upper Vertical Neutron Camera (UVNC). The contribution of each diagnostic in the port was evaluated by running separate upper port MCNP models those contain individual diagnostic only, and the total dose rate contribution was evaluated with the model which was fully integrated with all the diagnostics. The effect of the opening around the upper port plug and of the other ports was also investigated. The purpose of this assessment is to provide the shielding design basis for the preliminary design of the diagnostic integration in the port. The method and result of the calculation will be presented in this paper.

  8. The introduction, deployment and impact of assistant practitioners in diagnostic radiography in Scotland

    International Nuclear Information System (INIS)

    Price, R.; Miller, L.; Hicks, B.; Higgs, A.

    2015-01-01

    This article describes the outcomes of an evaluation of the impact of introducing Assistant Practitioners (AP) roles into imaging departments in 13 of the 14 NHS Boards in Scotland. Between 2006 and 2009 some 34 individuals were trained as APs in diagnostic radiography with 33 subsequently taking up AP posts. In 2010 NHS Education for Scotland commissioned an evaluation of the impact brought about through introduction of the diagnostic imaging AP role in imaging departments. The research found that a minority of the managers had considered the workforce implications of introducing the new roles or the supervisory arrangements that would be required. In some sites implementation of the roles had resulted in the release of radiographers for additional training and higher level activities, but in others financial constraints had limited such initiatives. Managers believed that APs had helped maintain or improve service capacity and quality. - Highlights: • Minority of managers consider implications of new roles or supervisory arrangements. • Assistant practitioners (APs) help maintain or improve service capacity and quality. • Financial constraints limit training and initiatives. • APs can allow staff release for training and work in specialist modalities. • Data collection key in measuring financial effectiveness, capacity and impact

  9. Active and Passive Diagnostic Signatures of Special Nuclear Materials

    Energy Technology Data Exchange (ETDEWEB)

    Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, Steven Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-26

    An overview will be given discussing signatures associated with special nuclear materials acquired using both active and passive diagnostic techniques. Examples of how technology advancements have helped improve diagnostic capabilities to meet the challenges of today’s applications will be discussed.

  10. Diagnostic challenges of childhood asthma.

    Science.gov (United States)

    Bakirtas, Arzu

    2017-01-01

    Diagnosis of asthma in childhood is challenging. Both underdiagnosis and overdiagnosis of asthma are important issues. The present review gives information about challenging factors for an accurate diagnosis of childhood asthma. Although underdiagnosis of asthma in childhood has always been the most important diagnostic problem, overdiagnosis of asthma has also been increasingly recognized. This is probably due to diagnosis of asthma based on symptoms and signs alone. Demonstration of variable airflow obstruction by lung function tests is the most common asthma diagnostic tests used in practice and is therefore strongly recommended in children who can cooperate. Recently, an asthma guideline combining the clinical and economic evidences with sensitivity and specificity of diagnostic procedures was developed to improve accuracy of diagnosis and to avoid overdiagnosis. This guideline provided an algorithmic clinical and cost-effective approach and included fractional exhaled nitric oxide measurement as one of the diagnostic tests in addition to lung function. Diagnosis of asthma in children should be made by combining relevant history with at least two confirmatory diagnostic tests whenever possible. Diagnosis based on short-period treatment trials should be limited to young children who are unable to cooperate with these tests.

  11. Diagnostic accuracy of optical coherence tomography in actinic keratosis and basal cell carcinoma.

    Science.gov (United States)

    Olsen, J; Themstrup, L; De Carvalho, N; Mogensen, M; Pellacani, G; Jemec, G B E

    2016-12-01

    Early diagnosis of non-melanoma skin cancer (NMSC) is potentially possible using optical coherence tomography (OCT) which provides non-invasive, real-time images of skin with micrometre resolution and an imaging depth of up to 2mm. OCT technology for skin imaging has undergone significant developments, improving image quality substantially. The diagnostic accuracy of any method is influenced by continuous technological development making it necessary to regularly re-evaluate methods. The objective of this study is to estimate the diagnostic accuracy of OCT in basal cell carcinomas (BCC) and actinic keratosis (AK) as well as differentiating these lesions from normal skin. A study set consisting of 142 OCT images meeting selection criterea for image quality and diagnosis of AK, BCC and normal skin was presented uniformly to two groups of blinded observers: 5 dermatologists experienced in OCT-image interpretation and 5 dermatologists with no experience in OCT. During the presentation of the study set the observers filled out a standardized questionnaire regarding the OCT diagnosis. Images were captured using a commercially available OCT machine (Vivosight ® , Michelson Diagnostics, UK). Skilled OCT observers were able to diagnose BCC lesions with a sensitivity of 86% to 95% and a specificity of 81% to 98%. Skilled observers with at least one year of OCT-experience showed an overall higher diagnostic accuracy compared to inexperienced observers. The study shows an improved diagnostic accuracy of OCT in differentiating AK and BCC from healthy skin using state-of-the-art technology compared to earlier OCT technology, especially concerning BCC diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. AAPT Diagnostic Criteria for Chronic Cancer Pain Conditions.

    Science.gov (United States)

    Paice, Judith A; Mulvey, Matt; Bennett, Michael; Dougherty, Patrick M; Farrar, John T; Mantyh, Patrick W; Miaskowski, Christine; Schmidt, Brian; Smith, Thomas J

    2017-03-01

    Chronic cancer pain is a serious complication of malignancy or its treatment. Currently, no comprehensive, universally accepted cancer pain classification system exists. Clarity in classification of common cancer pain syndromes would improve clinical assessment and management. Moreover, an evidence-based taxonomy would enhance cancer pain research efforts by providing consistent diagnostic criteria, ensuring comparability across clinical trials. As part of a collaborative effort between the Analgesic, Anesthetic, and Addiction Clinical Trial Translations, Innovations, Opportunities, and Networks (ACTTION) and the American Pain Society (APS), the ACTTION-APS Pain Taxonomy initiative worked to develop the characteristics of an optimal diagnostic system. After the establishment of these characteristics, a working group consisting of clinicians and clinical and basic scientists with expertise in cancer and cancer-related pain was convened to generate core diagnostic criteria for an illustrative sample of 3 chronic pain syndromes associated with cancer (ie, bone pain and pancreatic cancer pain as models of pain related to a tumor) or its treatment (ie, chemotherapy-induced peripheral neuropathy). A systematic review and synthesis was conducted to provide evidence for the dimensions that comprise this cancer pain taxonomy. Future efforts will subject these diagnostic categories and criteria to systematic empirical evaluation of their feasibility, reliability, and validity and extension to other cancer-related pain syndromes. The ACTTION-APS chronic cancer pain taxonomy provides an evidence-based classification for 3 prevalent syndromes, namely malignant bone pain, pancreatic cancer pain, and chemotherapy-induced peripheral neuropathy. This taxonomy provides consistent diagnostic criteria, common features, comorbidities, consequences, and putative mechanisms for these potentially serious cancer pain conditions that can be extended and applied with other cancer

  13. Proposed minimal diagnostic criteria for myelodysplastic syndromes (MDS) and potential pre-MDS conditions.

    Science.gov (United States)

    Valent, Peter; Orazi, Attilio; Steensma, David P; Ebert, Benjamin L; Haase, Detlef; Malcovati, Luca; van de Loosdrecht, Arjan A; Haferlach, Torsten; Westers, Theresia M; Wells, Denise A; Giagounidis, Aristoteles; Loken, Michael; Orfao, Alberto; Lübbert, Michael; Ganser, Arnold; Hofmann, Wolf-Karsten; Ogata, Kiyoyuki; Schanz, Julie; Béné, Marie C; Hoermann, Gregor; Sperr, Wolfgang R; Sotlar, Karl; Bettelheim, Peter; Stauder, Reinhard; Pfeilstöcker, Michael; Horny, Hans-Peter; Germing, Ulrich; Greenberg, Peter; Bennett, John M

    2017-09-26

    Myelodysplastic syndromes (MDS) comprise a heterogeneous group of myeloid neoplasms characterized by peripheral cytopenia, dysplasia, and a variable clinical course with about 30% risk to transform to secondary acute myeloid leukemia (AML). In the past 15 years, diagnostic evaluations, prognostication, and treatment of MDS have improved substantially. However, with the discovery of molecular markers and advent of novel targeted therapies, new challenges have emerged in the complex field of MDS. For example, MDS-related molecular lesions may be detectable in healthy individuals and increase in prevalence with age. Other patients exhibit persistent cytopenia of unknown etiology without dysplasia. Although these conditions are potential pre-phases of MDS they may also transform into other bone marrow neoplasms. Recently identified molecular, cytogenetic, and flow-based parameters may add in the delineation and prognostication of these conditions. However, no generally accepted integrated classification and no related criteria are as yet available. In an attempt to address this challenge, an international consensus group discussed these issues in a working conference in July 2016. The outcomes of this conference are summarized in the present article which includes criteria and a proposal for the classification of pre-MDS conditions as well as updated minimal diagnostic criteria of MDS. Moreover, we propose diagnostic standards to delineate between ´normal´, pre-MDS, and MDS. These standards and criteria should facilitate diagnostic and prognostic evaluations in clinical studies as well as in clinical practice.

  14. Molecular diagnostics clinical utility strategy: a six-part framework.

    Science.gov (United States)

    Frueh, Felix W; Quinn, Bruce

    2014-09-01

    The clinical utility of a molecular test rises proportional to a favorable regulatory risk/benefit assessment, and clinical utility is the driver of payer coverage decisions. Although a great deal has been written about clinical utility, debates still center on its 'definition.' We argue that the definition (an impact on clinical outcomes) is self-evident, and improved communications should focus on sequential steps in building and proving an adequate level of confidence for the diagnostic test's clinical value proposition. We propose a six-part framework to facilitate communications between test developers and health technology evaluators, relevant to both regulatory and payer decisions.

  15. Reducing the throughput time of the diagnostic track involving CT scanning with computer simulation

    Energy Technology Data Exchange (ETDEWEB)

    Lent, Wineke A.M. van, E-mail: w.v.lent@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); University of Twente, IGS Institute for Innovation and Governance Studies, Department of Health Technology Services Research (HTSR), Enschede (Netherlands); Deetman, Joost W., E-mail: j.deetman@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Teertstra, H. Jelle, E-mail: h.teertstra@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Muller, Sara H., E-mail: s.muller@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); Hans, Erwin W., E-mail: e.w.hans@utwente.nl [University of Twente, School of Management and Governance, Dept. of Industrial Engineering and Business Intelligence Systems, Enschede (Netherlands); Harten, Wim H. van, E-mail: w.v.harten@nki.nl [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), P.O. Box 90203, 1006 BE Amsterdam (Netherlands); University of Twente, IGS Institute for Innovation and Governance Studies, Department of Health Technology Services Research (HTSR), Enschede (Netherlands)

    2012-11-15

    Introduction: To examine the use of computer simulation to reduce the time between the CT request and the consult in which the CT report is discussed (diagnostic track) while restricting idle time and overtime. Methods: After a pre implementation analysis in our case study hospital, by computer simulation three scenarios were evaluated on access time, overtime and idle time of the CT; after implementation these same aspects were evaluated again. Effects on throughput time were measured for outpatient short-term and urgent requests only. Conclusion: The pre implementation analysis showed an average CT access time of 9.8 operating days and an average diagnostic track of 14.5 operating days. Based on the outcomes of the simulation, management changed the capacity for the different patient groups to facilitate a diagnostic track of 10 operating days, with a CT access time of 7 days. After the implementation of changes, the average diagnostic track duration was 12.6 days with an average CT access time of 7.3 days. The fraction of patients with a total throughput time within 10 days increased from 29% to 44% while the utilization remained equal with 82%, the idle time increased by 11% and the overtime decreased by 82%. The fraction of patients that completed the diagnostic track within 10 days improved with 52%. Computer simulation proved useful for studying the effects of proposed scenarios in radiology management. Besides the tangible effects, the simulation increased the awareness that optimizing capacity allocation can reduce access times.

  16. Reducing the throughput time of the diagnostic track involving CT scanning with computer simulation

    International Nuclear Information System (INIS)

    Lent, Wineke A.M. van; Deetman, Joost W.; Teertstra, H. Jelle; Muller, Sara H.; Hans, Erwin W.; Harten, Wim H. van

    2012-01-01

    Introduction: To examine the use of computer simulation to reduce the time between the CT request and the consult in which the CT report is discussed (diagnostic track) while restricting idle time and overtime. Methods: After a pre implementation analysis in our case study hospital, by computer simulation three scenarios were evaluated on access time, overtime and idle time of the CT; after implementation these same aspects were evaluated again. Effects on throughput time were measured for outpatient short-term and urgent requests only. Conclusion: The pre implementation analysis showed an average CT access time of 9.8 operating days and an average diagnostic track of 14.5 operating days. Based on the outcomes of the simulation, management changed the capacity for the different patient groups to facilitate a diagnostic track of 10 operating days, with a CT access time of 7 days. After the implementation of changes, the average diagnostic track duration was 12.6 days with an average CT access time of 7.3 days. The fraction of patients with a total throughput time within 10 days increased from 29% to 44% while the utilization remained equal with 82%, the idle time increased by 11% and the overtime decreased by 82%. The fraction of patients that completed the diagnostic track within 10 days improved with 52%. Computer simulation proved useful for studying the effects of proposed scenarios in radiology management. Besides the tangible effects, the simulation increased the awareness that optimizing capacity allocation can reduce access times.

  17. An Evaluation of the Performance Diagnostic Checklist-Human Services (PDC-HS) Across Domains.

    Science.gov (United States)

    Wilder, David A; Lipschultz, Joshua; Gehrman, Chana

    2018-06-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) is an informant-based tool designed to assess the environmental variables that contribute to poor employee performance in human service settings. Although the PDC-HS has been shown to effectively identify variables contributing to problematic performance, interventions based on only two of the four PDC-HS domains have been evaluated to date. In addition, the extent to which PDC-HS-indicated interventions are more effective than nonindicated interventions for two domains remains unclear. In the current study, we administered the PDC-HS to supervisors to assess the variables contributing to infrequent teaching of verbal operants and use of a timer by therapists at a center-based autism treatment program. Each of the four PDC-HS domains was identified as contributing to poor performance for at least one therapist. We then evaluated PDC-HS-indicated interventions for each domain. In addition, to assess the predictive validity of the tool, we evaluated various nonindicated interventions prior to implementing a PDC-HS-indicated intervention for two of the four domains. Results suggest that the PDC-HS-indicated interventions were effective across all four domains and were more effective than the nonindicated interventions for the two domains for which they were evaluated. Results are discussed in terms of the utility of the PDC-HS to identify appropriate interventions to manage therapist performance in human service settings.

  18. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    Science.gov (United States)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 0.05). The measurements of the two methods were highly correlated (r = 0.969, p human eye to diagnose non-invasively the severity of strabismus.

  19. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  20. Use of Capillary Blood Samples Leads to Higher Parasitemia Estimates and Higher Diagnostic Sensitivity of Microscopic and Molecular Diagnostics of Malaria than Venous Blood Samples.

    Science.gov (United States)

    Mischlinger, Johannes; Pitzinger, Paul; Veletzky, Luzia; Groger, Mirjam; Zoleko-Manego, Rella; Adegnika, Ayola A; Agnandji, Selidji T; Lell, Bertrand; Kremsner, Peter G; Tannich, Egbert; Mombo-Ngoma, Ghyslain; Mordmüller, Benjamin; Ramharter, Michael

    2018-05-25

    Diagnosis of malaria is usually based on samples of peripheral blood. However, it is unclear whether capillary (CAP) or venous (VEN) blood samples provide better diagnostic performance. Quantitative differences of parasitemia between CAP and VEN blood and diagnostic performance characteristics were investigated. Patients were recruited between September 2015 and February 2016 in Gabon. Light microscopy and qPCR quantified parasitemia of paired CAP and VEN samples, whose preparation followed the exact same methodology. CAP and VEN performance characteristics using microscopy were evaluated against a qPCR gold-standard. Microscopy revealed a median (IQR) parasites/L of 495 (853,243) in CAP and 429 (524,074) in VEN samples manifesting in a +16.6% (p=0.04) higher CAPparasitemia compared with VENparasitemia. Concordantly, qPCR demonstrated that -0.278 (p=0.006) cycles were required for signal detection in CAP samples. CAPsensitivity of microscopy relative to the gold-standard was 81.5% (77.485.6%) versus VENsensitivity of 73.4% (68.878.1%), while CAPspecificity and VENspecificity were 91%. CAPsensitivity and VENsensitivity dropped to 63.3% and 45.9%, respectively for a sub-population of low-level parasitemias while specificities were 92%. CAP sampling leads to higher parasitemias compared to VEN sampling and improves diagnostic sensitivity. These findings may have important implications for routine diagnostics, research and elimination campaigns of malaria.