WorldWideScience

Sample records for implementation assessment device

  1. Application of Devices and Systems Designed for Power Quality Monitoring and Assessment

    Directory of Open Access Journals (Sweden)

    Wiesław Gil

    2014-03-01

    Full Text Available The paper presents the problems associated with increasing demands on the equipment and systems for power quality assessment (PQ, installed at power substations. Difficulties are signaled due to current lack of standards defining the test methodology of measuring devices. The necessary device properties and the structure of a large system operated in real time and designed to assess the PQ are discussed. The usefulness of multi-channel analyzers featuring the identification and registration of transients is pointed out. The desirability of synchrophasor assessment implementation and device integration by standard PN-EN 61850 with other SAS devices is also justified.

  2. Registry Assessment of Peripheral Interventional Devices (RAPID): Registry assessment of peripheral interventional devices core data elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert A; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L

    2018-02-01

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  3. Registry Assessment of Peripheral Interventional Devices (RAPID) - Registry Assessment of Peripheral Interventional Devices Core Data Elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L; Nc, Durham; Md, Silver Spring; Japan, Tokyo; Ny, New York; Ri, Providence; Vt, Burlington; Mass, Newton; Colo, Denver; Ariz, Tempe; Calif, Santa Clara; Minn, Minneapolis; Nh, Lebanon

    2018-01-25

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.

  4. Integrated neuron circuit for implementing neuromorphic system with synaptic device

    Science.gov (United States)

    Lee, Jeong-Jun; Park, Jungjin; Kwon, Min-Woo; Hwang, Sungmin; Kim, Hyungjin; Park, Byung-Gook

    2018-02-01

    In this paper, we propose and fabricate Integrate & Fire neuron circuit for implementing neuromorphic system. Overall operation of the circuit is verified by measuring discrete devices and the output characteristics of the circuit. Since the neuron circuit shows asymmetric output characteristic that can drive synaptic device with Spike-Timing-Dependent-Plasticity (STDP) characteristic, the autonomous weight update process is also verified by connecting the synaptic device and the neuron circuit. The timing difference of the pre-neuron and the post-neuron induce autonomous weight change of the synaptic device. Unlike 2-terminal devices, which is frequently used to implement neuromorphic system, proposed scheme of the system enables autonomous weight update and simple configuration by using 4-terminal synapse device and appropriate neuron circuit. Weight update process in the multi-layer neuron-synapse connection ensures implementation of the hardware-based artificial intelligence, based on Spiking-Neural- Network (SNN).

  5. Implementation of Adaptive Digital Controllers on Programmable Logic Devices

    Science.gov (United States)

    Gwaltney, David A.; King, Kenneth D.; Smith, Keary J.; Monenegro, Justino (Technical Monitor)

    2002-01-01

    Much has been made of the capabilities of FPGA's (Field Programmable Gate Arrays) in the hardware implementation of fast digital signal processing. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used proportional-integral-derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM-based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a DSP (Digital Signal Processor) or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using digital signal processor (DSP) devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, pulse width modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive control algorithm approaches. An alternative is required for compact implementation of such functionality to withstand the harsh environment

  6. On the Implementation of the IEC 61850 Standard: Will Different Manufacturer Devices Behave Similarly under Identical Conditions?

    Directory of Open Access Journals (Sweden)

    Mohamad El Hariri

    2016-12-01

    Full Text Available Standardization in smart grid communications is necessary to facilitate complex operations of modern power system functions. However, the strong coupling between the cyber and physical domains of the contemporary grid exposes the system to vulnerabilities and thus places more burden on standards’ developers. As such, standards need to be continuously assessed for reliability and are expected to be implemented properly on field devices. However, the actual implementation of common standards varies between vendors, which may lead to different behaviors of the devices even if present under similar conditions. The work in this paper tested the implementation of the International Electro-technical Commission’s Generic Object Oriented Substation Event GOOSE (IEC 61850 GOOSE messaging protocol on commercial Intelligent Electronic Devices (IEDs and the open source libiec61850 library—also used in commercial devices—which showed different behaviors in identical situations. Based on the test results and analysis of some features of the IEC 61850 GOOSE protocol itself, this paper proposes guidelines and recommendations for proper implementation of the standard functionalities.

  7. Efficient Implementation of Solvers for Linear Model Predictive Control on Embedded Devices

    DEFF Research Database (Denmark)

    Frison, Gianluca; Kwame Minde Kufoalor, D.; Imsland, Lars

    2014-01-01

    This paper proposes a novel approach for the efficient implementation of solvers for linear MPC on embedded devices. The main focus is to explain in detail the approach used to optimize the linear algebra for selected low-power embedded devices, and to show how the high-performance implementation...

  8. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  9. Clinical implementation of a new HDR brachytherapy device for partial breast irradiation

    International Nuclear Information System (INIS)

    Scanderbeg, Daniel J.; Yashar, Catheryn; Rice, Roger; Pawlicki, Todd

    2009-01-01

    Purpose: To present the clinical implementation of a new HDR device for partial breast irradiation, the Strut-Adjusted Volume Implant (SAVI), at the University of California, San Diego. Methods and materials: The SAVI device has multiple peripheral struts that can be differentially loaded with the HDR source. Planning criteria used for evaluation of the treatment plans included the following dose volume histogram (DVH) criteria: V90 >90%, V150 <50 cc and V200 <20 cc. Results: SAVI has been used on 20 patients to date at UC San Diego. In each case, the dose was modulated according to patient-specific anatomy to cover the tumor bed, while sparing normal tissues. The dosimetric data show that we can achieve greater than 90% coverage with respect to V90 (median of 95.3%) and also keep a low V150 and V200 dose at 24.5 and 11.2 cc, respectively. Complete treatment can be done within a 30-min time slot, which includes implant verification, setup, and irradiation time as well as wound dressing. Conclusion: SAVI has been implemented at UC San Diego for accelerated partial breast irradiation with excellent tumor bed conformance and minimal normal tissue exposure. Patient positioning is the key to identifying any inter-fraction device motion. Device asymmetry or tissue conformance has been shown to resolve itself 24 h after the device implantation. The device can be implemented into an existing HDR program with minimal effort

  10. A practical method for the maintainability assessment in industrial devices using indicators and specific attributes

    International Nuclear Information System (INIS)

    Moreu De Leon, Pedro; González-Prida Díaz, Vicente; Barberá Martínez, Luis; Crespo Márquez, Adolfo

    2012-01-01

    The objective of this paper is to describe a procedure to obtain maintainability indicators for industrial devices. This analysis can be helpful, among other cases, to compare systems, to achieve a better design regarding maintainability requirements, to improve this maintainability under specific industrial environment and to foresee maintainability problems due to eventual changes in a device operation conditions. This maintainability assessment can be carried out at any stage of the industrial asset life cycle. With this purpose, this work first introduces the notion of maintainability and the implementation of assessment indicators, including some important requirements to perform that. Then, a brief literature review is presented, including the definition of the main concepts, which are later used in the paper. After studying the maintenance levels and the maintainability attributes, both terms are linked, leading all this analysis to the assessment of the maintainability indicators. It follows a discussion about the information obtained through the maintainability assessment process and its computation into several maintainability indicators. The paper includes a case study, which implements the defined assessment into a practical scenario. Finally, the work concludes summarizing the more significant aspects and suggesting future researches.

  11. Integrating mobile devices into nursing curricula: opportunities for implementation using Rogers' Diffusion of Innovation model.

    Science.gov (United States)

    Doyle, Glynda J; Garrett, Bernie; Currie, Leanne M

    2014-05-01

    To identify studies reporting mobile device integration into undergraduate and graduate nursing curricula. To explore the potential use of Rogers' Diffusion of Innovation model as a framework to guide implementation of mobile devices into nursing curricula. Literature review and thematic categorization. Literature published up until June 2013 was searched using EBSCO, PubMed, and Google Scholar. The literature was reviewed for research articles pertaining to mobile device use in nursing education. Research articles were grouped by study design, and articles were classified by: 1) strategies for individual adopters and 2) strategies for organizations. Rogers' Diffusion of Innovation theory was used to categorize reported implementation strategies. Fifty-two research studies were identified. Strategies for implementation were varied, and challenges to integrating mobile devices include lack of administrative support and time/funding to educate faculty as well as students. Overall, the use of mobile devices appears to provide benefits to nursing students; however the research evidence is limited. Anticipating challenges and ensuring a well laid out strategic plan can assist in supporting successful integration of mobile devices. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  12. Implementation of Keystroke Dynamics for Multi-factor Authentication on Mobile Devices

    Directory of Open Access Journals (Sweden)

    D. A. Sokolov

    2010-06-01

    Full Text Available The article considers the possibility of using biometric authentication methods for mobile devices. The implementation of keystroke dynamics-based authentication system is presented. Testing process and results are described.

  13. Prototyping of concurrent control systems implemented in FPGA devices

    CERN Document Server

    Wiśniewski, Remigiusz

    2017-01-01

    This book focuses on prototyping aspects of concurrent control systems and their further implementation and partial reconfiguration in programmable devices. Further, it lays out a full prototyping flow for concurrent control systems. Based on a given primary specification, a system is described with an interpreted Petri net, which naturally reflects the concurrent and sequential relationships of the design. The book shows that, apart from the traditional option of static configuration of the entire system, the latest programmable devices (especially FPGAs) offer far more sophistication. Partial reconfiguration allows selected parts of the system to be replaced without having to reprogram the entire structure of the device. Approaches to dynamic and static partial reconfiguration of concurrent control systems are presented and described in detail.< The theoretical work is illustrated by examples drawn from various applications, with a milling machine and a traffic-light controller highlighted as representat...

  14. Non-Hebbian learning implementation in light-controlled resistive memory devices.

    Science.gov (United States)

    Ungureanu, Mariana; Stoliar, Pablo; Llopis, Roger; Casanova, Fèlix; Hueso, Luis E

    2012-01-01

    Non-Hebbian learning is often encountered in different bio-organisms. In these processes, the strength of a synapse connecting two neurons is controlled not only by the signals exchanged between the neurons, but also by an additional factor external to the synaptic structure. Here we show the implementation of non-Hebbian learning in a single solid-state resistive memory device. The output of our device is controlled not only by the applied voltages, but also by the illumination conditions under which it operates. We demonstrate that our metal/oxide/semiconductor device learns more efficiently at higher applied voltages but also when light, an external parameter, is present during the information writing steps. Conversely, memory erasing is more efficiently at higher applied voltages and in the dark. Translating neuronal activity into simple solid-state devices could provide a deeper understanding of complex brain processes and give insight into non-binary computing possibilities.

  15. HEALTH TECHNOLOGY ASSESSMENT OF MEDICAL DEVICES IN EUROPE: PROCESSES, PRACTICES, AND METHODS.

    Science.gov (United States)

    Fuchs, Sabine; Olberg, Britta; Panteli, Dimitra; Busse, Reinhard

    2016-01-01

    To review and compare current Health Technology Assessment (HTA) activities for medical devices (MDs) across European HTA institutions. A comprehensive approach was adopted to identify institutions involved in HTA in European countries. We systematically searched institutional Web sites and other online sources by using a structured tool to extract information on the role and link to decision making, structure, scope, process, methodological approach, and available HTA reports for each included institution. Information was obtained from eighty-four institutions, forty-seven of which were analyzed. Fifty-four methodological documents from twenty-three agencies in eighteen countries were identified. Only five agencies had separate documents for the assessment of MDs. A few agencies made separate provisions for the assessment of MDs in their general methods. The amount of publicly available HTA reports on MDs varied by device category and agency remit. Despite growing consensus on their importance and international initiatives, such as the EUnetHTA Core Model®, specific tools for the assessment of MDs are rarely developed and implemented at the national level. Separate additional signposts incorporated in existing general methods guides may be sufficient for the evaluation of MDs.

  16. Implementation methodology for interoperable personal health devices with low-voltage low-power constraints.

    Science.gov (United States)

    Martinez-Espronceda, Miguel; Martinez, Ignacio; Serrano, Luis; Led, Santiago; Trigo, Jesús Daniel; Marzo, Asier; Escayola, Javier; Garcia, José

    2011-05-01

    Traditionally, e-Health solutions were located at the point of care (PoC), while the new ubiquitous user-centered paradigm draws on standard-based personal health devices (PHDs). Such devices place strict constraints on computation and battery efficiency that encouraged the International Organization for Standardization/IEEE11073 (X73) standard for medical devices to evolve from X73PoC to X73PHD. In this context, low-voltage low-power (LV-LP) technologies meet the restrictions of X73PHD-compliant devices. Since X73PHD does not approach the software architecture, the accomplishment of an efficient design falls directly on the software developer. Therefore, computational and battery performance of such LV-LP-constrained devices can even be outperformed through an efficient X73PHD implementation design. In this context, this paper proposes a new methodology to implement X73PHD into microcontroller-based platforms with LV-LP constraints. Such implementation methodology has been developed through a patterns-based approach and applied to a number of X73PHD-compliant agents (including weighing scale, blood pressure monitor, and thermometer specializations) and microprocessor architectures (8, 16, and 32 bits) as a proof of concept. As a reference, the results obtained in the weighing scale guarantee all features of X73PHD running over a microcontroller architecture based on ARM7TDMI requiring only 168 B of RAM and 2546 B of flash memory.

  17. Implementation of Order-wire Functionality in IRITEL NG-SDH devices

    Directory of Open Access Journals (Sweden)

    D. Katanić

    2011-06-01

    Full Text Available This paper describes the implementation of order-wire functionality in NG-SDH devices ODS2G5 and OTS622 IRITEL. The paper also describes the operation of order-wire in networks with arbitrary topologies, as well as the configuration of order-wire functionality by using network management software SUNCE. The presented solution for order-wire functionality is compared with VoIP solutions. The paper shows that the presented solution provides fast reaction to network failures, while keeping the implementation simple.

  18. Device for assessing radio-photoluminescence glasses

    International Nuclear Information System (INIS)

    Hoegl, A.; Schubert, K.

    1979-01-01

    The UV light irradiating the glass and the luminescence light caused by the UV light are collected in separate measuring paths. In order to correct the affect of changes of intensity of the UV light source on the amount of luminescence, both measuring paths are connected by programmed control, a comparison device and a correcting device. There are integrating stages in both measuring paths, which are followed by analogue digital converters with an assessment device. (DG) [de

  19. PANATIKI: A Network Access Control Implementation Based on PANA for IoT Devices

    Directory of Open Access Journals (Sweden)

    Antonio F. Gomez Skarmeta

    2013-11-01

    Full Text Available Internet of Things (IoT networks are the pillar of recent novel scenarios, such as smart cities or e-healthcare applications. Among other challenges, these networks cover the deployment and interaction of small devices with constrained capabilities and Internet protocol (IP-based networking connectivity. These constrained devices usually require connection to the Internet to exchange information (e.g., management or sensing data or access network services. However, only authenticated and authorized devices can, in general, establish this connection. The so-called authentication, authorization and accounting (AAA services are in charge of performing these tasks on the Internet. Thus, it is necessary to deploy protocols that allow constrained devices to verify their credentials against AAA infrastructures. The Protocol for Carrying Authentication for Network Access (PANA has been standardized by the Internet engineering task force (IETF to carry the Extensible Authentication Protocol (EAP, which provides flexible authentication upon the presence of AAA. To the best of our knowledge, this paper is the first deep study of the feasibility of EAP/PANA for network access control in constrained devices. We provide light-weight versions and implementations of these protocols to fit them into constrained devices. These versions have been designed to reduce the impact in standard specifications. The goal of this work is two-fold: (1 to demonstrate the feasibility of EAP/PANA in IoT devices; (2 to provide the scientific community with the first light-weight interoperable implementation of EAP/PANA for constrained devices in the Contiki operating system (Contiki OS, called PANATIKI. The paper also shows a testbed, simulations and experimental results obtained from real and simulated constrained devices.

  20. PANATIKI: a network access control implementation based on PANA for IoT devices.

    Science.gov (United States)

    Moreno Sanchez, Pedro; Marin Lopez, Rafa; Gomez Skarmeta, Antonio F

    2013-11-01

    Internet of Things (IoT) networks are the pillar of recent novel scenarios, such as smart cities or e-healthcare applications. Among other challenges, these networks cover the deployment and interaction of small devices with constrained capabilities and Internet protocol (IP)-based networking connectivity. These constrained devices usually require connection to the Internet to exchange information (e.g., management or sensing data) or access network services. However, only authenticated and authorized devices can, in general, establish this connection. The so-called authentication, authorization and accounting (AAA) services are in charge of performing these tasks on the Internet. Thus, it is necessary to deploy protocols that allow constrained devices to verify their credentials against AAA infrastructures. The Protocol for Carrying Authentication for Network Access (PANA) has been standardized by the Internet engineering task force (IETF) to carry the Extensible Authentication Protocol (EAP), which provides flexible authentication upon the presence of AAA. To the best of our knowledge, this paper is the first deep study of the feasibility of EAP/PANA for network access control in constrained devices. We provide light-weight versions and implementations of these protocols to fit them into constrained devices. These versions have been designed to reduce the impact in standard specifications. The goal of this work is two-fold: (1) to demonstrate the feasibility of EAP/PANA in IoT devices; (2) to provide the scientific community with the first light-weight interoperable implementation of EAP/PANA for constrained devices in the Contiki operating system (Contiki OS), called PANATIKI. The paper also shows a testbed, simulations and experimental results obtained from real and simulated constrained devices.

  1. Developing an Assessment (Tool) for Touch Screen Devices.

    Science.gov (United States)

    Danial-Saad, Alexandra; Chiari, Lorenzo

    2017-01-01

    Touch screen devices have become prevalent in our lives. Assistive technology experts working with people with disabilities face difficulty in understanding and assessing the problems experienced by individuals with disabilities in operating touch screen devices. This paper presents the processes of collecting and creating the required knowledge needed for assessing the user's skills for operating various touch screen devices, in order to develop an application for assessing the user's abilities and limitations. A six step procedure was used to collect and validate the required knowledge for the assessment from a multidisciplinary team. To determine the agreement levels between the experts, content validity was calculated. To test correlation between the experts from the different disciplines, a comparison was made between the discipline groups and their choice of specific skills/measurements. The final number of domains and skills/measurements was 15 domains and 50 skills/measurements. The result of Cronbach's α test for the final assessment questionnaire (50 skills/measurements) was 0.94, which indicates a high degree of reliability. The results of Kruskal-Wallis test showed the lack of any significant difference between agreements of the clinicians and the technicians groups, but significant differences were found between the educators and the clinicians groups. Each of the skills appearing in the final questionnaire was illustrated in a flowchart in preparation for developing the assessment (tool) for using touch screen devices.

  2. Management assessments of Quality Assurance Program implementation effectiveness

    International Nuclear Information System (INIS)

    Snyder, D.A.

    1984-01-01

    This paper describes a method currently being used by UNC Nuclear Industries, Richland, Washington, to help assure the effectiveness of Quality Assurance (QA) Program implementation. Assessments are conducted annually by management in each department, and the results summarized to the president and his staff. The purpose of these assessments is to review the adequacy of the department's implementing procedures, training/instruction on implementing procedures, and procedure implementation effectiveness. The primary purpose is to assess effectiveness and take improvement action where the need is indicated. The QA organization provides only general guidance in conducting the assessments

  3. Performance Assessment of Communication Enhancement Devices TEA HI Threat Headset

    Science.gov (United States)

    2015-08-01

    AFRL-RH-WP-TR-2015-0076 Performance Assessment of Communication Enhancement Devices: TEA HI Threat Headset Hilary L. Gallagher...of Communication Enhancement Devices: TEA HI Threat Headset 5a. CONTRACT NUMBER FA8650-14-D-6501 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...technology in military applications. Objective performance data provided an assessment of the performance of these devices. The TEA HI Threat headset

  4. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  5. Translation and validation of the assistive technology device predisposition assessment in Greek in order to assess satisfaction with use of the selected assistive device.

    Science.gov (United States)

    Koumpouros, Yiannis; Papageorgiou, Effie; Karavasili, Alexandra; Alexopoulou, Despoina

    2017-07-01

    To examine the Assistive Technology Device Predisposition Assessment scale and provide evidence of validity and reliability of the Greek version. We translated and adapted the original instrument in Greek according to the most well-known guidelines recommendations. Field test studies were conducted in a rehabilitation hospital to validate the appropriateness of the final results. Ratings of the different items were statistically analyzed. We recruited 115 subjects who were administered the Form E of the original questionnaire. The experimental analysis conducted revealed a three subscales structure: (i) Adaptability, (ii) Fit to Use, and (iii) Socializing. According to the results of our study the three subscales measure different constructs. Reliability measures (ICC = 0.981, Pearson's correlation = 0.963, Cronbach's α = 0.701) yielded high values. Test-retest outcome showed great stability. This is the first study, at least to the knowledge of the authors, which focuses merely on measuring the satisfaction of the users from the used assistive device, while exploring the Assistive Technology Device Predisposition Assessment - Device Form in such depth. According to the results, it is a stable, valid and reliable instrument and applicable to the Greek population. Thus, it can be used to measure the satisfaction of patients with assistive devices. Implications for Rehabilitation The paper explores the cultural adaptability and applicability of ATD PA - Device Form. ATD PA - Device Form can be used to assess user satisfaction by the selected assistive device. ATD PA - Device Form is a valid and reliable instrument in measuring users' satisfaction in Greekreality.

  6. FOTOSAN DEVICE IMPLEMENTATION IN COMPLEX TREATMENT OF ORAL AND LABIAL MUSCOSA DISEASES

    Directory of Open Access Journals (Sweden)

    T. S. Chizhikova

    2015-01-01

    Full Text Available The article presents data about Fotosan device and its implementation in complex treatment of oral and labial muscosa diseases. The obtained results evidence that 84% of observed patients had significant reduction of pain, swellings and regeneration acceleration in 1.5 – 2 times

  7. A randomized trial of standardized nursing patient assessment using wireless devices.

    Science.gov (United States)

    Dykes, Patricia C; Carroll, Diane L; Benoit, Angela; Coakley, Amanda; Chang, Frank; Empoliti, Joanne; Gallagher, Joan; Lasala, Cynthia; O'Malley, Rosemary; Rath, Greg; Silva, Judy; Li, Qi

    2007-10-11

    A complete and accurate patient assessment database is essential for effective communication, problem identification, planning and evaluation of patient status. When employed consistently for point-of-care documentation, information systems are associated with completeness and quality of documentation. The purpose of this paper is to report on the findings of a randomized, cross-over study conducted to evaluate the adequacy of a standard patient assessment module to support problem identification, care planning and tracking of nursing sensitive patient outcomes. The feasibility of wireless devices to support patient assessment data collection at the point-of-care was evaluated using wireless PDAs and tablet PCs. Seventy-nine (79) nurses from two patient care units at Massachusetts General Hospital (Boston, MA) were recruited into the study and randomized to complete patient assessment using wireless or paper devices. At the end of six weeks, nurses who where randomized to the paper assessment module were assigned to a device and those who used a device were assigned to paper for an additional six weeks. Impact was evaluated with regard to data capture, workflow implications and nurse satisfaction. Findings suggest that a standard patient assessment set promotes patient sensitive and quality data capture, which is augmented by the use of wireless devices.

  8. Implementation of heat production and storage technology and devices in power systems

    International Nuclear Information System (INIS)

    Romanovsky, G.; Mutale, J.

    2012-01-01

    Implementation of heat storage devices and technologies at power generation plants is a promising way to provide more efficient use of natural energy resources. Heat storage devices can partly replace conventional heating technologies (such as direct use of fossil fuels) during peak energy demand or in the situations where heat and electricity supply and demand do not coincide and to obtain low cost heat energy which can be further transmitted to industrial, commercial and domestic consumers. This paper presents the innovative Heat Production and Storage Device and its application at conventional, nuclear and renewable power generation plants for optimization and balancing of electricity grids. The Heat Production and Storage Device is a vessel type induction-immersion heat production and storage device which produces pre-heated water under pressure for heat energy conservation. Operation of this device is based on simultaneous and/or sequential action of an inductor and an immersion heater and can be easily connected to the electricity network as a single or a three phase unit. Heat energy accumulated by the Heat Production and Storage Device can be utilized in different industrial technological processes during periods of high energy prices. - Highlights: ► Heat Production and Storage Device for energy conservation within low load hours. ► Simultaneous and/or sequential operation of the inductor and immersion heater. ► Transform the energy of low frequency electrical current (50 Hz) into heat energy. ► Connection to the electricity network either in single or three phase unit. ► Heat Production and Storage Device will enhance the economic value of the system.

  9. Assessment of CANDU-6 reactivity devices for DUPIC fuel

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    1998-11-01

    Reactivity device characteristics for a CANDU 6 reactor loaded with DUPIC fuel have been assessed. The lattice parameters were generated by WIMS-AECL code and the core calculations were performed by RFSP code with a 3-dimensional full core model. The reactivity devices studied are the zone controller, adjusters, mechanical control absorber and shutoff rods. For the zone controller system, damping capability for spatial oscillation was investigated. For the adjusters, the restart capability was investigated. For the adjusters, the restart capability was investigated. The shin operation and power stepback calculation were also performed to confirm the compatibility of the current adjuster system. The mechanical control absorber was assessed for the function of compensating temperature reactivity feedback following a power reduction. And shutoff rods were also assessed to investigate the following a power reduction. And shutoff rods were also assessed to investigate the static reactivity worth. This study has shown that the current reactivity device system of CANDU-6 core with the DUPIC fuel. (author). 9 refs., 17 tabs., 7 figs

  10. Australia; Basel II Implementation Assessment

    OpenAIRE

    International Monetary Fund

    2010-01-01

    The key findings of Australia’s BASEL II implementation assessment are presented. The Australian Prudential Regulation Authority (APRA) allocated sufficient resources, including highly skilled staff, prior to the Basel II start date, and the outcome has been a robust and high-quality implementation that has built upon and substantially strengthened the risk-management capabilities of major banks. The quality of leadership and commitment by all involved has been instrumental in the success of ...

  11. Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association.

    Science.gov (United States)

    Mairesse, Georges H; Braunschweig, Frieder; Klersy, Katherine; Cowie, Martin R; Leyva, Francisco

    2015-05-01

    Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  12. Implementation of BES-III TOF trigger system in programmable logic devices

    International Nuclear Information System (INIS)

    Zheng Wei; Liu Shubin; Liu Xuzong; An Qi

    2009-01-01

    The TOF trigger sub-system on the upgrading Beijing Spectrometer is designed to receive 368 bits fast hit signals from the front end electronics module to yield 7 bits trigger information according to the physical requirement. It sends the processed real time trigger information to the Global-Trigger-Logic to generate the primal trigger signal L1, and sends processed 136 bits real time position information to the Track-Match-Logic to calculate the particle flight tracks. The sub-system also packages the valid events for the DAQ system to read out. Following the reconfigurable concept, a large number of programmable logic devices are employed to increase the flexibility and reliability of the system, and decrease the complexity and the space requirement of PCB layout. This paper describes the implementation of the kernel trigger logic in a programmable logic device. (authors)

  13. Assessment of reactivity devices for CANDU-6 with DUPIC fuel

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    1998-01-01

    Reactivity device characteristics for a CANDU-6 reactor loaded with DUPIC fuel have been assessed. A transport code WIMS-AECL and a three-dimensional diffusion code RFSP were used for the lattice parameter generation and the core calculation, respectively. Three major reactivity devices have been assessed for their inherent functions. For the zone controller system, damping capability for spatial oscillation was investigated. The restart capability of the adjuster system was investigated. The shim operation and power stepback calculation were also performed to confirm the compatibility of the current adjuster rod system. The mechanical control absorber was assessed for the capability to compensate the temperature reactivity feedback following a power reduction. This study has shown that the current reactivity device systems retain their functions when used in a DUPIC fuel CANDU reactor

  14. Commercial Mobile Device Technology Implementation Implications in United States Marine Corps Processes: A Case Study Approach

    Science.gov (United States)

    2016-09-01

    University MDM mobile device management MOS military occupational specialty M-SHARP Marine-Sierra Hotel Aviation Readiness Program NAVAIR Naval...levels, and from low employee satisfaction to high employee satisfaction , as displayed in Figure 1. Figure 1. Implementation Categories. Source...Soldiers. The key take-away from their survey results is that if given a choice no specific device would satisfy all customers ; however, a portfolio of

  15. A New Tool for Assessing Mobile Device Proficiency in Older Adults: The Mobile Device Proficiency Questionnaire.

    Science.gov (United States)

    Roque, Nelson A; Boot, Walter R

    2018-02-01

    Mobile device proficiency is increasingly required to participate in society. Unfortunately, there still exists a digital divide between younger and older adults, especially with respect to mobile devices (i.e., tablet computers and smartphones). Training is an important goal to ensure that older adults can reap the benefits of these devices. However, efficient/effective training depends on the ability to gauge current proficiency levels. We developed a new scale to accurately assess the mobile device proficiency of older adults: the Mobile Device Proficiency Questionnaire (MDPQ). We present and validate the MDPQ and a short 16-question version of the MDPQ (MDPQ-16). The MDPQ, its subscales, and the MDPQ-16 were found to be highly reliable and valid measures of mobile device proficiency in a large sample. We conclude that the MDPQ and MDPQ-16 may serve as useful tools for facilitating mobile device training of older adults and measuring mobile device proficiency for research purposes.

  16. Radiation-Tolerance Assessment of a Redundant Wireless Device

    Science.gov (United States)

    Huang, Q.; Jiang, J.

    2018-01-01

    This paper presents a method to evaluate radiation-tolerance without physical tests for a commercial off-the-shelf (COTS)-based monitoring device for high level radiation fields, such as those found in post-accident conditions in a nuclear power plant (NPP). This paper specifically describes the analysis of radiation environment in a severe accident, radiation damages in electronics, and the redundant solution used to prolong the life of the system, as well as the evaluation method for radiation protection and the analysis method of system reliability. As a case study, a wireless monitoring device with redundant and diversified channels is evaluated by using the developed method. The study results and system assessment data show that, under the given radiation condition, performance of the redundant device is more reliable and more robust than those non-redundant devices. The developed redundant wireless monitoring device is therefore able to apply in those conditions (up to 10 M Rad (Si)) during a severe accident in a NPP.

  17. Implementation of a risk assessment tool based on a probabilistic safety assessment developed for radiotherapy practices

    International Nuclear Information System (INIS)

    Paz, A.; Godinez, V.; Lopez, R.

    2010-10-01

    The present work describes the implementation process and main results of the risk assessment to the radiotherapy practices with Linear Accelerators (Linac), with cobalt 60, and with brachytherapy. These evaluations were made throughout the risk assessment tool for radiotherapy practices SEVRRA (risk evaluation system for radiotherapy), developed at the Mexican National Commission in Nuclear Safety and Safeguards derived from the outcome obtained with the Probabilistic Safety Analysis developed at the Ibero-American Regulators Forum for these radiotherapy facilities. The methodology used is supported by risk matrices method, a mathematical tool that estimates the risk to the patient, radiation workers and public from mechanical failures, mis calibration of the devices, human mistakes, and so. The initiating events are defined as those undesirable events that, together with other failures, can produce a delivery of an over-dose or an under-dose of the medical prescribed dose, to the planned target volume, or a significant dose to non prescribed human organs. Initiating events frequency and reducer of its frequency (actions intended to avoid the accident) are estimated as well as robustness of barriers to those actions, such as mechanical switches, which detect and prevent the accident from occurring. The spectrum of the consequences is parameterized, and the actions performed to reduce the consequences are identified. Based on this analysis, a software tool was developed in order to simplify the evaluations to radiotherapy installations and it has been applied as a first step forward to some Mexican installations, as part of a national implementation process, the final goal is evaluation of all Mexican facilities in the near future. The main target and benefits of the SEVRRA implementation are presented in this paper. (Author)

  18. Implementation of a risk assessment tool based on a probabilistic safety assessment developed for radiotherapy practices

    Energy Technology Data Exchange (ETDEWEB)

    Paz, A.; Godinez, V.; Lopez, R., E-mail: abpaz@cnsns.gob.m [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)

    2010-10-15

    The present work describes the implementation process and main results of the risk assessment to the radiotherapy practices with Linear Accelerators (Linac), with cobalt 60, and with brachytherapy. These evaluations were made throughout the risk assessment tool for radiotherapy practices SEVRRA (risk evaluation system for radiotherapy), developed at the Mexican National Commission in Nuclear Safety and Safeguards derived from the outcome obtained with the Probabilistic Safety Analysis developed at the Ibero-American Regulators Forum for these radiotherapy facilities. The methodology used is supported by risk matrices method, a mathematical tool that estimates the risk to the patient, radiation workers and public from mechanical failures, mis calibration of the devices, human mistakes, and so. The initiating events are defined as those undesirable events that, together with other failures, can produce a delivery of an over-dose or an under-dose of the medical prescribed dose, to the planned target volume, or a significant dose to non prescribed human organs. Initiating events frequency and reducer of its frequency (actions intended to avoid the accident) are estimated as well as robustness of barriers to those actions, such as mechanical switches, which detect and prevent the accident from occurring. The spectrum of the consequences is parameterized, and the actions performed to reduce the consequences are identified. Based on this analysis, a software tool was developed in order to simplify the evaluations to radiotherapy installations and it has been applied as a first step forward to some Mexican installations, as part of a national implementation process, the final goal is evaluation of all Mexican facilities in the near future. The main target and benefits of the SEVRRA implementation are presented in this paper. (Author)

  19. Assurance of Medical Device Quality with Quality Management System: An Analysis of Good Manufacturing Practice Implementation in Taiwan

    Directory of Open Access Journals (Sweden)

    Tzu-Wei Li

    2015-01-01

    Full Text Available The implementation of an effective quality management system has always been considered a principal method for a manufacturer to maintain and improve its product and service quality. Globally many regulatory authorities incorporate quality management system as one of the mandatory requirements for the regulatory control of high-risk medical devices. The present study aims to analyze the GMP enforcement experience in Taiwan between 1998 and 2013. It describes the regulatory implementation of medical device GMP requirement and initiatives taken to assist small and medium-sized enterprises in compliance with the regulatory requirement. Based on statistical data collected by the competent authority and industry research institutes, the present paper reports the growth of Taiwan local medical device industry after the enforcement of GMP regulation. Transition in the production, technologies, and number of employees of Taiwan medical device industry between 1998 and 2013 provides the competent authorities around the world with an empirical foundation for further policy development.

  20. Value-based purchasing of medical devices.

    Science.gov (United States)

    Obremskey, William T; Dail, Teresa; Jahangir, A Alex

    2012-04-01

    Health care in the United States is known for its continued innovation and production of new devices and techniques. While the intention of these devices is to improve the delivery and outcome of patient care, they do not always achieve this goal. As new technologies enter the market, hospitals and physicians must determine which of these new devices to incorporate into practice, and it is important these devices bring value to patient care. We provide a model of a physician-engaged process to decrease cost and increase review of physician preference items. We describe the challenges, implementation, and outcomes of cost reduction and product stabilization of a value-based process for purchasing medical devices at a major academic medical center. We implemented a physician-driven committee that standardized and utilized evidence-based, clinically sound, and financially responsible methods for introducing or consolidating new supplies, devices, and technology for patient care. This committee worked with institutional finance and administrative leaders to accomplish its goals. Utilizing this physician-driven committee, we provided access to new products, standardized some products, decreased costs of physician preference items 11% to 26% across service lines, and achieved savings of greater than $8 million per year. The implementation of a facility-based technology assessment committee that critically evaluates new technology can decrease hospital costs on implants and standardize some product lines.

  1. Design and Implementation of Pointer-Type Multi Meters Intelligent Recognition Device Based on ARM Platform

    Science.gov (United States)

    Cui, Yang; Luo, Wang; Fan, Qiang; Peng, Qiwei; Cai, Yiting; Yao, Yiyang; Xu, Changfu

    2018-01-01

    This paper adopts a low power consumption ARM Hisilicon mobile processing platform and OV4689 camera, combined with a new skeleton extraction based on distance transform algorithm and the improved Hough algorithm for multi meters real-time reading. The design and implementation of the device were completed. Experimental results shows that The average error of measurement was 0.005MPa, and the average reading time was 5s. The device had good stability and high accuracy which meets the needs of practical application.

  2. Safety assessment in plant layout design using indexing approach: Implementing inherent safety perspective

    International Nuclear Information System (INIS)

    Tugnoli, Alessandro; Khan, Faisal; Amyotte, Paul; Cozzani, Valerio

    2008-01-01

    Layout planning plays a key role in the inherent safety performance of process plants since this design feature controls the possibility of accidental chain-events and the magnitude of possible consequences. A lack of suitable methods to promote the effective implementation of inherent safety in layout design calls for the development of new techniques and methods. In the present paper, a safety assessment approach suitable for layout design in the critical early phase is proposed. The concept of inherent safety is implemented within this safety assessment; the approach is based on an integrated assessment of inherent safety guideword applicability within the constraints typically present in layout design. Application of these guidewords is evaluated along with unit hazards and control devices to quantitatively map the safety performance of different layout options. Moreover, the economic aspects related to safety and inherent safety are evaluated by the method. Specific sub-indices are developed within the integrated safety assessment system to analyze and quantify the hazard related to domino effects. The proposed approach is quick in application, auditable and shares a common framework applicable in other phases of the design lifecycle (e.g. process design). The present work is divided in two parts: Part 1 (current paper) presents the application of inherent safety guidelines in layout design and the index method for safety assessment; Part 2 (accompanying paper) describes the domino hazard sub-index and demonstrates the proposed approach with a case study, thus evidencing the introduction of inherent safety features in layout design

  3. An implementation of the diagnosis method DYANA, applied to a combined heat-power device

    Energy Technology Data Exchange (ETDEWEB)

    Van der Neut, F.

    1993-10-01

    The development and implementation of the monitor-and-diagnosis method DYANA is presented. This implementation is applied to and tested on a combined heat and power generating device (CHP). The steps that have been taken in realizing this implementation are evaluated into detail . In chapter two the theory behind DYANA is recapitulated. Attention is paid to the basic theory of diagnoses, and the steps of the path from this theory to the algorithm DYANA are revealed. These steps include the hierarchical approach, and explain the following features of DYANA: a) the use of best-first dynamic model zooming based on heuristics with respect to parsimony of the number of components within the diagnoses, b) the use of consistency of fault models with observations to focus on the most likely diagnoses, and c) the use of online diagnosis: the current set of diagnoses is incrementally updated after a new observation of the system is made. In chapter three the relevant aspects of the system to be diagnosed, the CHP, are dealt with in detail. An explanation is given of the broad working of the CHP, its hierarchical structure and mathematical representation are given, CHP observation is commented, and some possible forms of fault models are stated. In chapter four the pseudocode of the implementation, developed for DYANA, is presented. The pseudocode consists of two parts: the monitoring process (using numerical simulation), and the diagnostic process. The differences between the pseudocode and the actual implementation are mentioned. The CHP will then be monitored and diagnosed with this algorithm and results of this test are given in chapter five. An actual implementation of DYANA can be found in a separately supplied appendix, the Programme Appendix. The implementation of the monitoring process is meant only for this example of the CHP. The code for the diagnostic process can be easily adjusted for diagnosing other devices, such as electronic circuits. The language is Pascal.

  4. Design of a robotic device for assessment and rehabilitation of hand sensory function.

    Science.gov (United States)

    Lambercy, Olivier; Robles, Alejandro Juárez; Kim, Yeongmi; Gassert, Roger

    2011-01-01

    This paper presents the design and implementation of the Robotic Sensory Trainer, a robotic interface for assessment and therapy of hand sensory function. The device can provide three types of well controlled stimuli: (i) angular displacement at the metacarpophalangeal (MCP) joint using a remote-center-of-motion double-parallelogram structure, (ii) vibration stimuli at the fingertip, proximal phalange and palm, and (iii) pressure at the fingertip, while recording position, interaction force and feedback from the user over a touch screen. These stimuli offer a novel platform to investigate sensory perception in healthy subjects and patients with sensory impairments, with the potential to assess deficits and actively train detection of specific sensory cues in a standardized manner. A preliminary study with eight healthy subjects demonstrates the feasibility of using the Robotic Sensory Trainer to assess the sensory perception threshold in MCP angular position. An average just noticeable difference (JND) in the MCP joint angle of 2.46° (14.47%) was found, which is in agreement with previous perception studies. © 2011 IEEE

  5. Lagrangian methods for blood damage estimation in cardiovascular devices--How numerical implementation affects the results.

    Science.gov (United States)

    Marom, Gil; Bluestein, Danny

    2016-01-01

    This paper evaluated the influence of various numerical implementation assumptions on predicting blood damage in cardiovascular devices using Lagrangian methods with Eulerian computational fluid dynamics. The implementation assumptions that were tested included various seeding patterns, stochastic walk model, and simplified trajectory calculations with pathlines. Post processing implementation options that were evaluated included single passage and repeated passages stress accumulation and time averaging. This study demonstrated that the implementation assumptions can significantly affect the resulting stress accumulation, i.e., the blood damage model predictions. Careful considerations should be taken in the use of Lagrangian models. Ultimately, the appropriate assumptions should be considered based the physics of the specific case and sensitivity analysis, similar to the ones presented here, should be employed.

  6. The Implementation of Continuous Assessment in Writing Classes ...

    African Journals Online (AJOL)

    The Implementation of Continuous Assessment in Writing Classes the of Jimma ... is the typical nature of summative tests was used to grade students' performance. ... Key words: Continuous assessment, Formative assessment, Summative ...

  7. Oral Assessment in Mathematics: Implementation and Outcomes

    Science.gov (United States)

    Iannone, P.; Simpson, A.

    2012-01-01

    In this article, we report the planning and implementation of an oral assessment component in a first-year pure mathematics module of a degree course in mathematics. Our aim was to examine potential barriers to using oral assessments, explore the advantages and disadvantages compared to existing common assessment methods and document the outcomes…

  8. [Implementation of safety devices: biological accident prevention].

    Science.gov (United States)

    Catalán Gómez, M Teresa; Sol Vidiella, Josep; Castellà Castellà, Manel; Castells Bo, Carolina; Losada Pla, Nuria; Espuny, Javier Lluís

    2010-04-01

    Accidental exposures to blood and biological material were the most frequent and potentially serious accidents in healthcare workers, reported in the Prevention of Occupational Risks Unit within 2002. Evaluate the biological percutaneous accidents decrease after a progressive introduction of safety devices. Biological accidents produced between 2.002 and 2.006 were analyzed and reported by the injured healthcare workers to the Level 2b Hospital Prevention of Occupational Risk Unit with 238 beds and 750 employees. The key of the study was the safety devices (peripheral i.v. catheter, needleless i.v. access device and capillary blood collection lancet). Within 2002, 54 percutaneous biological accidents were registered and 19 in 2006, that represents a 64.8% decreased. There has been no safety devices accident reported involving these material. Accidents registered during the implantation period occurred because safety devices were not used at that time. Safety devices have proven to be effective in reducing needle stick percutaneous accidents, so that they are a good choice in the primary prevention of biological accidents contact.

  9. Plans for Hand-Held/Portable Oil Assessment Devices

    National Research Council Canada - National Science Library

    Urbansky, Edward

    2005-01-01

    At the request of the U.S. Army Oil Analysis Program, the JOAP TSC conducted a market study, assembled a plan of action, and prepared a worksheet for the evaluation of portable or hand-held oil assessment devices...

  10. Left Atrial Appendage Closure Device With Delivery System: A Health Technology Assessment

    Science.gov (United States)

    Nevis, Immaculate; Falk, Lindsey; Wells, David; Higgins, Caroline

    2017-01-01

    Background Atrial fibrillation is a common cardiac arrhythmia, and 15% to 20% of those who have experienced stroke have atrial fibrillation. Treatment options to prevent stroke in people with atrial fibrillation include pharmacological agents such as novel oral anticoagulants or nonpharmacological devices such as the left atrial appendage closure device with delivery system (LAAC device). The objectives of this health technology assessment were to assess the clinical effectiveness and cost-effectiveness of the LAAC device versus novel oral anticoagulants in patients without contraindications to oral anticoagulants and versus antiplatelet agents in patients with contraindications to oral anticoagulants. Methods We performed a systematic review and network meta-analysis. We also conducted an economic literature review, economic evaluation, and budget impact analysis to assess the cost-effectiveness and budget impact of the LAAC device compared with novel oral anticoagulants and oral antiplatelet agents (e.g., aspirin). We also spoke with patients to better understand their preferences, perspectives, and values. Results Seven randomized controlled studies met the inclusion criteria for indirect comparison. Five studies assessed the effectiveness of novel oral anticoagulants versus warfarin, and two studies compared the LAAC device with warfarin. No studies were identified that compared the LAAC device with aspirin in patients in whom oral anticoagulants were contraindicated. Using the random effects model, we found that the LAAC device was comparable to novel oral anticoagulants in reducing stroke (odds ratio [OR] 0.85; credible interval [Cr.I] 0.63–1.05). Similarly, the reduction in the risk of all-cause mortality was comparable between the LAAC device and novel oral anticoagulants (OR 0.71; Cr.I 0.49–1.22). The LAAC device was found to be superior to novel oral anticoagulants in preventing hemorrhagic stroke (OR 0.45; Cr.I 0.29–0.79), whereas novel oral

  11. EU “Mobility” Partnerships: An Initial Assessment of Implementation Dynamics

    Directory of Open Access Journals (Sweden)

    Natasja Reslow

    2015-09-01

    Full Text Available Cooperation with non-EU countries is a central migration policy priority for the EU, and since 2008 eight Mobility Partnerships have been signed. Given the importance attached to this policy area, it is essential that policy-makers understand how EU external migration policy works in practice. However, the literature on the implementation of EU external migration policy is very limited. This article addresses this deficit, by conducting a conceptual assessment of implementation dynamics in the Mobility Partnerships. At this stage in the implementation process, it is not yet possible to assess whether the Mobility Partnerships have contributed to mobility, which is their stated aim. Instead, the literature on implementation is applied in a “backward” fashion, starting with the implementation dynamics at play. The article concludes that standard analytical frameworks for assessing implementation processes will need to be adapted for “new” policy tools featuring elements of flexibility or voluntary participation, in order to accurately capture implementation processes. Future research should adopt a critical, human rights-centred approach to the issue of implementation of EU external migration policy.

  12. Design and Implementation of Foot-Mounted Inertial Sensor Based Wearable Electronic Device for Game Play Application

    Directory of Open Access Journals (Sweden)

    Qifan Zhou

    2016-10-01

    Full Text Available Wearable electronic devices have experienced increasing development with the advances in the semiconductor industry and have received more attention during the last decades. This paper presents the development and implementation of a novel inertial sensor-based foot-mounted wearable electronic device for a brand new application: game playing. The main objective of the introduced system is to monitor and identify the human foot stepping direction in real time, and coordinate these motions to control the player operation in games. This proposed system extends the utilized field of currently available wearable devices and introduces a convenient and portable medium to perform exercise in a more compelling way in the near future. This paper provides an overview of the previously-developed system platforms, introduces the main idea behind this novel application, and describes the implemented human foot moving direction identification algorithm. Practical experiment results demonstrate that the proposed system is capable of recognizing five foot motions, jump, step left, step right, step forward, and step backward, and has achieved an over 97% accuracy performance for different users. The functionality of the system for real-time application has also been verified through the practical experiments.

  13. Tissue quality assessment using a novel direct elasticity assessment device (the E-finger): a cadaveric study of prostatectomy dissection.

    Science.gov (United States)

    Good, Daniel W; Khan, Ashfaq; Hammer, Steven; Scanlan, Paul; Shu, Wenmiao; Phipps, Simon; Parson, Simon H; Stewart, Grant D; Reuben, Robert; McNeill, S Alan

    2014-01-01

    Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection. Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E). Image analysis was performed with Image Pro Premier to determine the histology at each measurement point. Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to examine the use of elasticity assessment devices for tissue quality assessment with the aim of giving haptic feedback to surgeons performing complex surgery.

  14. Validating the Accuracy of Reaction Time Assessment on Computer-Based Tablet Devices.

    Science.gov (United States)

    Schatz, Philip; Ybarra, Vincent; Leitner, Donald

    2015-08-01

    Computer-based assessment has evolved to tablet-based devices. Despite the availability of tablets and "apps," there is limited research validating their use. We documented timing delays between stimulus presentation and (simulated) touch response on iOS devices (3rd- and 4th-generation Apple iPads) and Android devices (Kindle Fire, Google Nexus, Samsung Galaxy) at response intervals of 100, 250, 500, and 1,000 milliseconds (ms). Results showed significantly greater timing error on Google Nexus and Samsung tablets (81-97 ms), than Kindle Fire and Apple iPads (27-33 ms). Within Apple devices, iOS 7 obtained significantly lower timing error than iOS 6. Simple reaction time (RT) trials (250 ms) on tablet devices represent 12% to 40% error (30-100 ms), depending on the device, which decreases considerably for choice RT trials (3-5% error at 1,000 ms). Results raise implications for using the same device for serial clinical assessment of RT using tablets, as well as the need for calibration of software and hardware. © The Author(s) 2015.

  15. Detector-device-independent quantum key distribution: Security analysis and fast implementation

    International Nuclear Information System (INIS)

    Boaron, Alberto; Korzh, Boris; Boso, Gianluca; Martin, Anthony; Zbinden, Hugo; Houlmann, Raphael; Lim, Charles Ci Wen

    2016-01-01

    One of the most pressing issues in quantum key distribution (QKD) is the problem of detector side-channel attacks. To overcome this problem, researchers proposed an elegant “time-reversal” QKD protocol called measurement-device-independent QKD (MDI-QKD), which is based on time-reversed entanglement swapping. However, MDI-QKD is more challenging to implement than standard point-to-point QKD. Recently, an intermediary QKD protocol called detector-device-independent QKD (DDI-QKD) has been proposed to overcome the drawbacks of MDI-QKD, with the hope that it would eventually lead to a more efficient detector side-channel-free QKD system. Here, we analyze the security of DDI-QKD and elucidate its security assumptions. We find that DDI-QKD is not equivalent to MDI-QKD, but its security can be demonstrated with reasonable assumptions. On the more practical side, we consider the feasibility of DDI-QKD and present a fast experimental demonstration (clocked at 625 MHz), capable of secret key exchange up to more than 90 km.

  16. Development of a Device for Objective Assessment of Tinnitus in Humans

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-14-2-0180 TITLE: Development of a Device for Objective Assessment of Tinnitus in Humans PRINCIPAL INVESTIGATOR: Jeremy G...SUBTITLE Development of a Device for Objective Assessment of Tinnitus in Humans 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-2-0180 5c. PROGRAM...briefly (one paragraph) describes the subject, purpose and scope of the research. Tinnitus is the perception of sound in the ears or head when no

  17. Verification and Analysis of Implementing Virtual Electric Devices in Circuit Simulation of Pulsed DC Electrical Devices in the NI MULTISIM 10.1 Environment

    Directory of Open Access Journals (Sweden)

    V. A. Solov'ev

    2015-01-01

    Full Text Available The paper presents the analysis results of the implementation potential and evaluation of the virtual electric devices reliability when conducting circuit simulation of pulsed DC electrical devices in the NI Multisim 10.1environment. It analyses metrological properties of electric measuring devices and sensors of the NI Multisim 10.1environment. To calculate the reliable parameters of periodic non-sinusoidal electrical values based on their physical feasibility the mathematical expressions have been defined.To verify the virtual electric devices a circuit model of the power section of buck DC converter with enabled devices under consideration at its input and output is used as a consumer of pulse current of trapezoidal or triangular form. It is used as an example to show a technique to verify readings of virtual electric measuring devices in the NI Multisim 10.1environment.It is found that when simulating the pulsed DC electric devices to measure average and RMS voltage supply and current consumption values it is advisable to use the probe. Electric device power consumption read from the virtual power meter is equal to its average value, and its displayed power factor is inversely proportional to the input current form factor. To determine the RMS pulsed DC current by ammeter and multi-meter it is necessary to measure current by these devices in DC and AC modes, and then determine the RMS value of measurement results.Virtual electric devices verification has proved the possibility of their application to determine the energy performance of transistor converters for various purposes in the circuit simulation in the NI 10.1 Multisim environment, thus saving time of their designing.

  18. Implementation of the Leaching Environmental Assessment ...

    Science.gov (United States)

    LEAF provides a uniform and integrated approach for evaluating leaching from solid materials (e.g., waste, treated wastes such as by solidification/stabilization, secondary materials such as blast furnace slags, energy residuals such as coal fly ash, soil, sediments, mining and mineral processing wastes). Assessment using LEAF applies a stepwise approach that considers the leaching behavior of COPCs in response to chemical and physical factors that control and material properties across a range of plausible field conditions (US EPA, 2010). The framework provides the flexibility to tailor testing to site conditions and select the extent of testing based on assessment objectives and the level of detailed information needed to support decision-making. The main focus will be to discuss the implementation of LEAF in the US and the How to Guide that has recently been completed. To present the How To Guide for the implementation of the leaching environmental assessment framework to an international audience already familiar with comparable leaching tests in use in Europe. Will be meeting with European colleagues on their interest in expanding methods to include organics.

  19. Rockfall Hazard Process Assessment : Implementation Report

    Science.gov (United States)

    2017-10-01

    The Montana Department of Transportation (MDT) commissioned a new research program to improve assessment and management of its rock slope assets. The Department implemented a Rockfall Hazard Rating System (RHRS) program in 2005 and wished to add valu...

  20. Radiation damage assessment of Nb tunnel junction devices

    International Nuclear Information System (INIS)

    King, S.E.; Magno, R.; Maisch, W.G.

    1991-01-01

    This paper reports on the radiation hardness of a new technology using Josephson junctions that was explored by an irradiation using a fluence of 7.6 x 10 14 protons/cm 2 at an energy of 63 MeV from the U.C. Davis cyclotron. In what the authors believe is the first radiation assessment of Nb/Al 2 O 3 /Nb devices, the permanent damage in these devices was investigated. No permanent changes in the I-V characteristics of the junctions were observed indicating no significant level of material defects have occurred at this level of irradiation

  1. Implementing Portfolio Assessment in Lower-Secondary School

    Directory of Open Access Journals (Sweden)

    Anna Czura

    2013-05-01

    Full Text Available Since alternative assessment embraces highly authentic tasks consistent with classroom goals and instruction, its implementation in the language classroom is believed to promote collaboration with peers, transfer responsibility to the learners and, consequently, foster learner autonomy. This paper presents the results of a research study aiming to determine whether portfolio assessment contributes to the development of autonomy in adolescent learners. In order to collect the data, qualitative and quantative methods of research were applied. The research results reveal that the implementation of portfolio assessment failed to affect the overall level of learner autonomy. Introducing one selected pedagogical procedure does not suffice to foster learner autonomy. Teachers need to be ready to pass a portion of their authority to the learners, who, in turn, need to know how to use the new privileges judiciously.

  2. Design and implementation of multichannel global active structural acoustic control for a device casing

    Science.gov (United States)

    Mazur, Krzysztof; Wrona, Stanislaw; Pawelczyk, Marek

    2018-01-01

    The paper presents the idea and discussion on implementation of multichannel global active noise control systems. As a test plant an active casing is used. It has been developed by the authors to reduce device noise directly at the source by controlling vibration of its casing. To provide global acoustic effect in the whole environment, where the device operates, it requires a number of secondary sources and sensors for each casing wall, thus making the whole active control structure complicated, i.e. with a large number of interacting channels. The paper discloses all details concerning hardware setup and efficient implementation of control algorithms for the multichannel case. A new formulation is presented to introduce the distributed version of the Switched-error Filtered-reference Least Mean Squares (FXLMS) algorithm together with adaptation rate enhancement. The convergence rate of the proposed algorithm is compared with original Multiple-error FXLMS. A number of hints followed from many years of authors' experience on microprocessor control systems design and signal processing algorithms optimization are presented. They can be used for various active control and signal processing applications, both for academic research and commercialization.

  3. Implementing Curriculum-Embedded Formative Assessment in Primary School Science Classrooms

    Science.gov (United States)

    Hondrich, Annika Lena; Hertel, Silke; Adl-Amini, Katja; Klieme, Eckhard

    2016-01-01

    The implementation of formative assessment strategies is challenging for teachers. We evaluated teachers' implementation fidelity of a curriculum-embedded formative assessment programme for primary school science education, investigating both material-supported, direct application and subsequent transfer. Furthermore, the relationship between…

  4. The investigation and implementation of real-time face pose and direction estimation on mobile computing devices

    Science.gov (United States)

    Fu, Deqian; Gao, Lisheng; Jhang, Seong Tae

    2012-04-01

    The mobile computing device has many limitations, such as relative small user interface and slow computing speed. Usually, augmented reality requires face pose estimation can be used as a HCI and entertainment tool. As far as the realtime implementation of head pose estimation on relatively resource limited mobile platforms is concerned, it is required to face different constraints while leaving enough face pose estimation accuracy. The proposed face pose estimation method met this objective. Experimental results running on a testing Android mobile device delivered satisfactory performing results in the real-time and accurately.

  5. Translating Theory Into Practice: Implementing a Program of Assessment.

    Science.gov (United States)

    Hauer, Karen E; O'Sullivan, Patricia S; Fitzhenry, Kristen; Boscardin, Christy

    2018-03-01

    A program of assessment addresses challenges in learner assessment using a centrally planned, coordinated approach that emphasizes assessment for learning. This report describes the steps taken to implement a program of assessment framework within a medical school. A literature review on best practices in assessment highlighted six principles that guided implementation of the program of assessment in 2016-2017: (1) a centrally coordinated plan for assessment aligns with and supports a curricular vision; (2) multiple assessment tools used longitudinally generate multiple data points; (3) learners require ready access to information-rich feedback to promote reflection and informed self-assessment; (4) mentoring is essential to facilitate effective data use for reflection and learning planning; (5) the program of assessment fosters self-regulated learning behaviors; and (6) expert groups make summative decisions about grades and readiness for advancement. Implementation incorporated stakeholder engagement, use of multiple assessment tools, design of a coaching program, and creation of a learner performance dashboard. The assessment team monitors adherence to principles defining the program of assessment and gathers and responds to regular feedback from key stakeholders, including faculty, staff, and students. Next steps include systematically collecting evidence for validity of individual assessments and the program overall. Iterative review of student performance data informs curricular improvements. The program of assessment also highlights technology needs that will be addressed with information technology experts. The outcome ultimately will entail showing evidence of validity that the program produces physicians who engage in lifelong learning and provide high-quality patient care.

  6. Reliability and efficiency upgrades of power systems operation by implementing intelligent electronic devices with synchrophasor measurement technology support

    OpenAIRE

    Mokeev Alexey

    2017-01-01

    This paper reviews issues of reliability and efficiency upgrades of power systems functions by means of a widespread implementation of intelligent electronic devices (IED) in various purposes supporting synchrophasor measurement technology. Thus, such issues as IED’s operational analysis in the conditions of electromagnetic and electromechanical transient processes and synthesis of digital filters that improve static and dynamic responses of these devices play an important role in their devel...

  7. An optimal controller for an electric ventricular-assist device: theory, implementation, and testing.

    Science.gov (United States)

    Klute, G K; Tasch, U; Geselowitz, D B

    1992-04-01

    This paper addresses the development and testing of an optimal position feedback controller for the Penn State electric ventricular-assist device (EVAD). The control law is designed to minimize the expected value of the EVAD's power consumption for a targeted patient population. The closed-loop control law is implemented on an Intel 8096 microprocessor and in vitro test runs show that this controller improves the EVAD's efficiency by 15-21%, when compared with the performance of the currently used feedforward control scheme.

  8. Implementation of laser speckle contrast analysis as connection kit for mobile phone for assessment of skin blood flow

    Science.gov (United States)

    Jakovels, Dainis; Saknite, Inga; Spigulis, Janis

    2014-05-01

    Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.

  9. Assessment of the implementation of environmental management ...

    African Journals Online (AJOL)

    Assessment of the implementation of environmental management system in the construction ... Journal of Fundamental and Applied Sciences ... The Environmental Management System (EMS) illustrates a possible solution to reduce the ...

  10. Tissue quality assessment using a novel direct elasticity assessment device (the E-finger: a cadaveric study of prostatectomy dissection.

    Directory of Open Access Journals (Sweden)

    Daniel W Good

    Full Text Available Minimally invasive radical prostatectomy (RP (robotic and laparoscopic, have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc. We developed a micro-engineered device (6 mm2 sized [E-finger] capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection.Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E. Image analysis was performed with Image Pro Premier to determine the histology at each measurement point.Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = < 0.001. Intra-class correlation (ICC reliability tests showed good reliability (average ICC = 0.851. Sensitivity and specificity for tissue identification was 77% and 70% respectively to a resolution of 6 mm2.This cadaveric study has evaluated the ability of our elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to

  11. Implementation of a Flexible Bayesian Classifier for the Assessment of Patient’s Activities within a Real-time Personalized Mobile Application

    Directory of Open Access Journals (Sweden)

    V. Miskovic

    2017-02-01

    Full Text Available This paper presents an implementation of a mobile application that provides a real-time personalized assessment of patient’s activities by using a Flexible Bayesian Classifier. The personalized assessment is derived from data collected from the 3-axial accelerometer sensor and the counting steps sensor, both widespread among nowadays mobile devices. Despite the fact that online mobile solutions with Bayesian Classifier have been rare and insufficiently precise, we have proven that the accuracy of the proposed system within a defined data model is comparable to the accuracy of decision trees and neural networks.

  12. Reliability and efficiency upgrades of power systems operation by implementing intelligent electronic devices with synchrophasor measurement technology support

    Directory of Open Access Journals (Sweden)

    Mokeev Alexey

    2017-01-01

    Full Text Available This paper reviews issues of reliability and efficiency upgrades of power systems functions by means of a widespread implementation of intelligent electronic devices (IED in various purposes supporting synchrophasor measurement technology. Thus, such issues as IED’s operational analysis in the conditions of electromagnetic and electromechanical transient processes and synthesis of digital filters that improve static and dynamic responses of these devices play an important role in their development.

  13. Exploring a New Security Framework for Remote Patient Monitoring Devices

    Directory of Open Access Journals (Sweden)

    Brian Ondiege

    2017-02-01

    Full Text Available Security has been an issue of contention in healthcare. The lack of familiarity and poor implementation of security in healthcare leave the patients’ data vulnerable to attackers. The main issue is assessing how we can provide security in an RPM infrastructure. The findings in literature show there is little empirical evidence on proper implementation of security. Therefore, there is an urgent need in addressing cybersecurity issues in medical devices. Through the review of relevant literature in remote patient monitoring and use of a Microsoft threat modelling tool, we identify and explore current vulnerabilities and threats in IEEE 11073 standard devices to propose a new security framework for remote patient monitoring devices. Additionally, current RPM devices have a limitation on the number of people who can share a single device, therefore, we propose the use of NFC for identification in Remote Patient Monitoring (RPM devices for multi-user environments where we have multiple people sharing a single device to reduce errors associated with incorrect user identification. We finally show how several techniques have been used to build the proposed framework.

  14. A proposed protocol for remote control of automated assessment devices

    International Nuclear Information System (INIS)

    Kissock, P.S.; Pritchard, D.A.

    1996-01-01

    Systems and devices that are controlled remotely are becoming more common in security systems in the US Air Force and other government agencies to provide protection of valuable assets. These systems reduce the number of needed personnel while still providing a high level of protection. However, each remotely controlled device usually has its own communication protocol. This limits the ability to change devices without changing the system that provides the communications control to the device. Sandia is pursuing a standard protocol that can be used to communicate with the different devices currently in use, or may be used in the future, in the US Air Force and other government agencies throughout the security community. Devices to be controlled include intelligent pan/tilt mounts, day/night video cameras, thermal imaging cameras, and remote data processors. Important features of this protocol include the ability to send messages of varying length, identify the sender, and more importantly, control remote data processors. This paper describes the proposed public domain protocol, features, and examples of use. The authors hope to elicit comments from security technology developers regarding format and use of remotely controlled automated assessment devices

  15. IMPLEMENTING A VALUE ASSESSMENT TOOL FOR SERVICE INNOVATION IDEAS

    OpenAIRE

    TOR HELGE AAS

    2010-01-01

    There has not been much discussion of how firms may assess the value of service innovation projects ex-ante in the extant research literature. This paper theoretically derives a value assessment tool for service innovation ideas called QSI (tool for pre-Qualification of Service Innovation projects). Thereafter QSI is implemented in three firms and it is explored to what degree the implementation improved managerial decision making on service innovation projects and investments. The findings i...

  16. The information protection level assessment system implementation

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    Currently, the threat of various attacks increases significantly as automated systems become more widespread. On the basis of the conducted analysis the information protection level assessment system establishing objective was identified. The paper presents the information protection level assessment software implementation in the information system by applying the programming language C #. In conclusions the software features are identified and experimental results are represented.

  17. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  18. Full-band quantum simulation of electron devices with the pseudopotential method: Theory, implementation, and applications

    Science.gov (United States)

    Pala, M. G.; Esseni, D.

    2018-03-01

    This paper presents the theory, implementation, and application of a quantum transport modeling approach based on the nonequilibrium Green's function formalism and a full-band empirical pseudopotential Hamiltonian. We here propose to employ a hybrid real-space/plane-wave basis that results in a significant reduction of the computational complexity compared to a full plane-wave basis. To this purpose, we provide a theoretical formulation in the hybrid basis of the quantum confinement, the self-energies of the leads, and the coupling between the device and the leads. After discussing the theory and the implementation of the new simulation methodology, we report results for complete, self-consistent simulations of different electron devices, including a silicon Esaki diode, a thin-body silicon field effect transistor (FET), and a germanium tunnel FET. The simulated transistors have technologically relevant geometrical features with a semiconductor film thickness of about 4 nm and a channel length ranging from 10 to 17 nm. We believe that the newly proposed formalism may find applications also in transport models based on ab initio Hamiltonians, as those employed in density functional theory methods.

  19. DeviceNet-based device-level control in SSRF

    CERN Document Server

    Leng Yong Bin; Lu Cheng Meng; Miao Hai Feng; Liu Song Qiang; Shen Guo Bao

    2002-01-01

    The control system of Shanghai Synchrotron Radiation Facility is an EPICS-based distributed system. One of the key techniques to construct the system is the device-level control. The author describes the design and implementation of the DeviceNet-based device controller. A prototype of the device controller was tested in the experiments of magnet power supply and the result showed a precision of 3 x 10 sup - sup 5

  20. [Implementation of a national training assessment programme in anaesthesiology

    DEFF Research Database (Denmark)

    Skjelsager, K.; Malling, B.; Bested, K.M.

    2008-01-01

    INTRODUCTION: In 2004, outcome-based education and in-training assessment was introduced by a reform of postgraduate medical education in Denmark. An assessment programme covering the introductory year of anaesthesiology was constructed. The purpose of this study was to explore to which degree...... this programme was implemented in daily practice in the clinical departments and whether the recommended assessment protocol was followed. MATERIALS AND METHODS: A questionnaire was distributed to 26 departments and 38 trainees. RESULTS: The response rate for both groups exceeded 90%. Individual learning plans...... were prepared by (2/3) of the trainees according to both trainees and departments. The various methods in the assessment programme were implemented to a high degree. The use of structured clinical observations was reported by more than 70% of both groups. Global assessments were applied in more than 70...

  1. Implementing an Online Writing Assessment Strategy for Gerontology

    Science.gov (United States)

    Brown, Pamela S.; Hanks, Roma S.

    2008-01-01

    Assessment of student learning is a growing concern for programs in gerontology. This report focuses on the conception, design, funding, and implementation of an innovative online workshop to assess and improve writing skills of students enrolled in distance-learning gerontology classes. The approach is multidisciplinary and involves a…

  2. Wearable Device Control Platform Technology for Network Application Development

    Directory of Open Access Journals (Sweden)

    Heejung Kim

    2016-01-01

    Full Text Available Application development platform is the most important environment in IT industry. There are a variety of platforms. Although the native development enables application to optimize, various languages and software development kits need to be acquired according to the device. The coexistence of smart devices and platforms has rendered the native development approach time and cost consuming. Cross-platform development emerged as a response to these issues. These platforms generate applications for multiple devices based on web languages. Nevertheless, development requires additional implementation based on a native language because of the coverage and functions of supported application programming interfaces (APIs. Wearable devices have recently attracted considerable attention. These devices only support Bluetooth-based interdevice communication, thereby making communication and device control impossible beyond a certain range. We propose Network Application Agent (NetApp-Agent in order to overcome issues. NetApp-Agent based on the Cordova is a wearable device control platform for the development of network applications, controls input/output functions of smartphones and wearable/IoT through the Cordova and Native API, and enables device control and information exchange by external users by offering a self-defined API. We confirmed the efficiency of the proposed platform through experiments and a qualitative assessment of its implementation.

  3. Portable Integrated Wireless Device Threat Assessment to Aircraft Radio Systems

    Science.gov (United States)

    Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)

    2004-01-01

    An assessment was conducted on multiple wireless local area network (WLAN) devices using the three wireless standards for spurious radiated emissions to determine their threat to aircraft radio navigation systems. The measurement process, data and analysis are provided for devices tested using IEEE 802.11a, IEEE 802.11b, and Bluetooth as well as data from portable laptops/tablet PCs and PDAs (grouping known as PEDs). A comparison was made between wireless LAN devices and portable electronic devices. Spurious radiated emissions were investigated in the radio frequency bands for the following aircraft systems: Instrument Landing System Localizer and Glideslope, Very High Frequency (VHF) Communication, VHF Omnidirectional Range, Traffic Collision Avoidance System, Air Traffic Control Radar Beacon System, Microwave Landing System and Global Positioning System. Since several of the contiguous navigation systems were grouped under one encompassing measurement frequency band, there were five measurement frequency bands where spurious radiated emissions data were collected for the PEDs and WLAN devices. The report also provides a comparison between emissions data and regulatory emission limit.

  4. Implementation of a transcutaneous charger for fully implantable middle ear hearing device.

    Science.gov (United States)

    Lim, H; Yoon, Y; Lee, C; Park, I; Song, B; Cho, J

    2005-01-01

    A transcutaneous charger for the fully implantable middle ear hearing device (F-IMEHD), which can monitor the charging level of battery, has been designed and implemented. In order to recharge the battery of F-IMEHD, the electromagnetic coupling between primary coil at outer body and secondary coil at inner body has been used. Considering the implant condition of the F-IMEHD, the primary coil and the secondary coil have been designed. Using the resonance of LC tank circuit at each coil, transmission efficiency was increased. Since the primary and the secondary coil are magnetically coupled, the current variation of the primary coil is related with the impedance of internal resonant circuit. Using the principle mentioned above, the implanted module could transmit outward the information about charging state of battery or coupling between two coils by the changing internal impedance. As in the demonstrated results of experiment, the implemented charger has supplied the sufficient operating voltage for the implanted battery within about 10 mm distance. And also, it has been confirmed that the implanted module can transmit information outward by control of internal impedance.

  5. Training Staff to Implement Brief Stimulus Preference Assessments

    Science.gov (United States)

    Weldy, Christina R.; Rapp, John T.; Capocasa, Kelli

    2014-01-01

    We trained 9 behavioral staff members to conduct 2 brief preference assessments using 30-min video presentations that contained instructions and modeling. After training, we evaluated each staff member's implementation of the assessments in situ. Results indicated that 1 or 2 training sessions for each method were sufficient for teaching each…

  6. School Indoor Air Quality Assessment and Program Implementation.

    Science.gov (United States)

    Prill, R.; Blake, D.; Hales, D.

    This paper describes the effectiveness of a three-step indoor air quality (IAQ) program implemented by 156 schools in the states of Washington and Idaho during the 2000-2001 school year. An experienced IAQ/building science specialist conducted walk-through assessments at each school. These assessments documented deficiencies and served as an…

  7. Ghost Particle Velocimetry implementation in millimeters devices and comparison with μPIV

    Science.gov (United States)

    Riccomi, Marco; Alberini, Federico; Brunazzi, Elisabetta; Vigolo, Daniele

    2016-11-01

    Micro/milli-fluidic devices are becoming an important reference for several disciplines and are quickly increasing their applications in scientific, as well as industrial, environment. As a consequence, the development of techniques able to analyse these kinds of systems is required to allow their progress. Here we show the implementation of the Ghost Particle Velocimetry (GPV) for the flow velocity field investigation in milli-fluidic devices. This innovative technique has been recently introduced, and has been already proven to be useful in describing rapid phenomenon at a small scale. In this work, the GPV has been used to characterize the trapping of light suspended material in a branching junction. Experiments have been performed to identify the flow velocity field close to a millimeters scale T-junction, at different Reynolds numbers. Particularly interesting are the complex structures, such as vortices and recirculation zones, induced by the vortex breakdown phenomenon. The results obtained have been deeply validated and compared with the well-established μPIV, highlighting the differences in terms of qualitative and quantitative parameters. A performance comparison has been designed to underline the strengths and weaknesses of the two experimental techniques.

  8. Kyiv institutional buildings sector energy efficiency program: Lending and implementation assessment

    Energy Technology Data Exchange (ETDEWEB)

    Secrest, T.J.; Freeman, S.L. [Pacific Northwest National Lab., Richland, WA (United States); Popelka, A. [Tysak Engineering, Acton, MA (United States); Shestopal, P.A.; Gagurin, E.V. [Agency for Rational Energy Use and Ecology, Kyiv (Ukraine)

    1997-08-01

    The government of Ukraine, through the State Committee of Energy Conservation (State Committee), is considering the implementation of energy efficiency measures in state and municipal institutional buildings in the city of Kyiv. The State Committee entered into a Memorandum of Cooperation with the US Department of Energy (DOE) to conduct an assessment of the institutional buildings sector efficiency potential. This assessment will be used to support a potential loan by the World Bank for implementing a buildings efficiency improvement program in Kyiv. This report provides an assessment of the options for structuring the lending scenarios and the implementation of the program. Components to the lending structure are options for the disbursement of funds, options for the loan service, and other financial options and considerations. Program implementation includes management structures, reporting, installation activities, and post-installation activities such as training and verification.

  9. Theoretic models for recommendation and implementation of assistive technology

    Directory of Open Access Journals (Sweden)

    Ana Cristina de Jesus Alves

    2016-07-01

    Full Text Available Introduction: The latest international researches seek to understand the factors affecting the successful use of assistive technology devices through studies regarding the assessments systematizing; abandonment of devices; or theoric models that consider the aspects of those devices implementation. In Brazil the researches are focused on developing new technologies and there are still not sufficient studies related to the successful use of devices and ways of assistive technology implementation. Objective: To identify conceptual models used for indication and implementation of assistive technology devices. Method: Literature review. The survey was conducted in six databases: CINAHAL, Eric, GALE, LILACS, MEDLINE e PsycInfo. A critical analysis described by Grant and Booth was used. Results: There are no records of a Brazilian survey and among 29 selected articles, 17 conceptual models used in the area of AT were found; of these, 14 were specific to AT. The results showed that the new conceptual models of TA are under development and the conceptual model “Matching Person and Technology – MPT” was the most mentioned. Conclusion: We can observe that the practices related to TA area in international context shows a correlation with conceptual models, thus, we hope this study might have the capacity to contribute for the propagation of this precepts at national level

  10. Getting Real: Implementing Assessment Alternatives in Mathematics.

    Science.gov (United States)

    Hopkins, Martha H.

    1997-01-01

    Recounts experiences of a university professor who returned to the elementary classroom and attempted to implement the National Council of Teachers of Mathematics Standards and appropriate assessment methods, including nontraditional paper-and-pencil tasks, journal-like writing assignments, focused observations, and performance-based assessments…

  11. [New medical device hospital assessment: what kind of clinical data?].

    Science.gov (United States)

    Beaussier, H; Junot, H; Lancrenon, S; Faure, P

    2012-01-01

    Since 2003, the AP-HP medical devices committee (CODIMS) assess the therapeutic relevance of innovated medical device (MD) for the French AP-HP hospitals' group. To accomplish this task, the CODIMS asks manufacturers to bring out clinical arguments to justify the use of their MD in hospital. This work analyses retrospectively after 8years, all assessed MD until March 2011 and the scientific quality of the clinical data submitted by manufacturers to the CODIMS to purchase their MD. All MD were classed according to their certification's level (I, IIa, IIb, III, DMIA). The quality of available clinical studies (CS) provided by manufacturers for each case was assessed and classed according to five clinical relevance levels based on the evidence-based medecine standards (1-2: high methodology; 3-5: low methodology). One hundred and three MD files (80 % of class IIb and III MD) were analysed by the CODIMS (630CS). Our results highlight the lack of relevance of files that are provided to assess innovated MD: 29 files without any CS; concerning class IIb (32DMS, 221CS) and III (50, 342CS) MD, only 6 % of CS presented a correct clinical relevance level. And the situation did not get better during this assessment period. The CODIMS deplore the poor clinical relevance of files provided to assess MD (wrong comparator, inappropriate ends-points, insufficient follow-up to assess long-term security, small population studied). Future legislative developments for MD assessment are expected to improve this situation. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  12. Assessment and testing of industrial devices robustness against cyber security attacks

    International Nuclear Information System (INIS)

    Tilaro, F.; Copy, B.

    2012-01-01

    CERN (European Organization for Nuclear Research),like any organization, needs to achieve the conflicting objectives of connecting its operational network to Internet while at the same time keeping its industrial control systems secure from external and internal cyber attacks. Devices robustness represents a key link in the defense-in-depth concept as some attacks will inevitably penetrate security boundaries and thus require further protection measures. CERN - in collaboration with Siemens - has designed and implemented a dedicated working environment, the Test-bench for Robustness of Industrial Equipment. Such tests attempt to detect possible anomalies by exploiting corrupt communication channels and manipulating the normal behavior of the communication protocols, in the same way as a cyber attacker would proceed. Our approach consists of analyzing protocol implementations by injecting malformed PDUs (Protocol Data Unit) to corrupt the normal behaviour of the system. As a PDU typically has many fields, the number of possible syntactically faulty PDUs grows exponentially with the number of fields. In this document, we proposed a strategy to explore this huge test domain using a hybrid approach of fuzzing and syntax techniques, specifically developed to evaluate industrial device communication robustness. So far, not all the tests can be integrated into automatic tools, human analysis and management is necessary to discover and investigate specific possible failures

  13. Device-Centric Monitoring for Mobile Device Management

    Directory of Open Access Journals (Sweden)

    Luke Chircop

    2016-03-01

    Full Text Available The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centric properties (e.g. the user may not send more than 100 messages per day across all applications being difficult or impossible to verify. In this paper we present a device-centric approach to runtime verify the device behaviour against a device policy with the different applications acting as independent components contributing to the overall behaviour of the device. We also present an implementation for Android devices, and evaluate it on a number of device-centric policies, reporting the empirical results obtained.

  14. Problems of implementing continuous assessment in secondary ...

    African Journals Online (AJOL)

    The paper examined problems of implementing continuous assessment in secondary schools in Obowo local government area of Imo State, Nigeria. Data were collected with the aid of a structured questionnaire administered to 100 randomly selected respondents in the study area. Descriptive statistics were used for data ...

  15. Assessment and development of implementation models of health ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Assessment and development of implementation models of health-related ... The Contribution of Civil Society Organizations in Achieving Health for All ... Health Information for Maternal and Child Health Planning in Urban Bangladesh.

  16. Implementation of clinical research trials using web-based and mobile devices: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Roy Eagleson

    2017-03-01

    Full Text Available Abstract Background With the increasing implementation of web-based, mobile health interventions in clinical trials, it is crucial for researchers to address the security and privacy concerns of patient information according to high ethical standards. The full process of meeting these standards is often made more complicated due to the use of internet-based technology and smartphones for treatment, telecommunication, and data collection; however, this process is not well-documented in the literature. Results The Smart Heart Trial is a single-arm feasibility study that is currently assessing the effects of a web-based, mobile lifestyle intervention for overweight and obese children and youth with congenital heart disease in Southwestern Ontario. Participants receive telephone counseling regarding nutrition and fitness; and complete goal-setting activities on a web-based application. This paper provides a detailed overview of the challenges the study faced in meeting the high standards of our Research Ethics Board, specifically regarding patient privacy. Conclusion We outline our solutions, successes, limitations, and lessons learned to inform future similar studies; and model much needed transparency in ensuring high quality security and protection of patient privacy when using web-based and mobile devices for telecommunication and data collection in clinical research.

  17. Implementation of a map route analysis robot: combining an Android smart device and differential-drive robotic platform

    Directory of Open Access Journals (Sweden)

    Tseng Chi-Hung

    2017-01-01

    Full Text Available This paper proposes an easy-to-implement and relatively low-cost robotic platform with capability to realize image identification, object tracking, and Google Map route planning and navigation. Based on the JAVA and Bluetooth communication architectures, the system demonstrates the integration of Android smart devices and a differential-drive robotic platform.

  18. Performance of GPS-devices for environmental exposure assessment.

    Science.gov (United States)

    Beekhuizen, Johan; Kromhout, Hans; Huss, Anke; Vermeulen, Roel

    2013-01-01

    Integration of individual time-location patterns with spatially resolved exposure maps enables a more accurate estimation of personal exposures to environmental pollutants than using estimates at fixed locations. Current global positioning system (GPS) devices can be used to track an individual's location. However, information on GPS-performance in environmental exposure assessment is largely missing. We therefore performed two studies. First, a commute-study, where the commute of 12 individuals was tracked twice, testing GPS-performance for five transport modes and two wearing modes. Second, an urban-tracking study, where one individual was tracked repeatedly through different areas, focused on the effect of building obstruction on GPS-performance. The median error from the true path for walking was 3.7 m, biking 2.9 m, train 4.8 m, bus 4.9 m, and car 3.3 m. Errors were larger in a high-rise commercial area (median error=7.1 m) compared with a low-rise residential area (median error=2.2 m). Thus, GPS-performance largely depends on the transport mode and urban built-up. Although ~85% of all errors were 50 m. Modern GPS-devices are useful tools for environmental exposure assessment, but large GPS-errors might affect estimates of exposures with high spatial variability.

  19. Assessing the Implementation of Ghana's Patient Charter

    Science.gov (United States)

    Abekah-Nkrumah, Gordon; Manu, Abubakar; Atinga, Roger Ayimbillah

    2010-01-01

    Purpose: This paper seeks to assess the implementation of Ghana's Patients' Charter by investigating the level of awareness and knowledge of the Charter's content, some socio-demographic factors that may influence awareness and knowledge of the Charter and how providers have discharged their responsibilities under the Charter.…

  20. The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

    Directory of Open Access Journals (Sweden)

    Ascaso Carlos

    2010-04-01

    Full Text Available Abstract Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

  1. Vision Assessment and Prescription of Low Vision Devices

    OpenAIRE

    Keeffe, Jill

    2004-01-01

    Assessment of vision and prescription of low vision devices are part of a comprehensive low vision service. Other components of the service include training the person affected by low vision in use of vision and other senses, mobility, activities of daily living, and support for education, employment or leisure activities. Specialist vision rehabilitation agencies have services to provide access to information (libraries) and activity centres for groups of people with impaired vision.

  2. [Risk assessment and risk control for occupational exposure to chemical toxicants from an isophorone nitrile device].

    Science.gov (United States)

    Wang, Dejun; Fu, Xiaokuan; Kong, Fanling; Sui, Shaofeng; Jiang, Yuanyuan; Du, Yinglin; Zhou, Jingyang

    2014-06-01

    Risk assessment and risk control for occupational exposure to chemical toxicants were performed on an isophorone nitrile device with an annual production of 5,000 tons, based on improved Singaporean semi-quantitative risk assessment method, with consideration of actual situation in China and in the present project. With the use of engineering analysis and identification of occupational hazards in the improved Singaporean semi-quantitative risk assessment method, hazard rating (HR) and risk assessment were performed on chemical toxicants from an isophorone nitrile device with an annual production of 5,000 tons. The chemical toxicants in the isophorone nitrile device were mainly isophorone, hydrocyanic acid, methanol, phosphoric acid, sodium hydroxide, and sodium cyanide; the HR values were mild hazard (2), extreme hazard (5), mild hazard (2), mild hazard (2), moderate hazard (3), and extreme hazard (5), respectively, and the corresponding exposure rating (ER) values were 2.09, 2.72, 2.76, 1.68, 2.0, and 1.59, respectively. The risk of chemical toxicants in this project was assessed according to the formula Risk = [HR×ER](1/2). Hydrocyanic acid was determined as high risk, sodium hydroxide and sodium cyanide as medium risk, and isophorone, methanol, and phosphoric acid as low risk. Priority in handling of risks was determined by risk rating. The table of risk control measure was established for pre-assessment of occupational hazards. With risk assessment in this study, we concluded that the isophorone nitrile device with 5,000 ton annual production was a high-occupational hazard device. This device is a project of extreme occupational hazard. The improved Singaporean semi-quantitative risk assessment method is a scientific and applicable method, and is especially suitable for pre-evaluation of on-site project with no analogy.

  3. Sperm quality assessment via separation and sedimentation in a microfluidic device.

    Science.gov (United States)

    Chen, Chang-Yu; Chiang, Tsun-Chao; Lin, Cheng-Ming; Lin, Shu-Sheng; Jong, De-Shien; Tsai, Vincent F-S; Hsieh, Ju-Ton; Wo, Andrew M

    2013-09-07

    A major reason for infertility is due to male factors, including the quality of spermatozoa, which is a primary factor and often difficult to assess, particularly the total sperm concentration and its motile percentage. This work presents a simple microfluidic device to assess sperm quality by quantifying both total and motile sperm counts. The key design feature of the microfluidic device is two channels separated by a permeative phase-guide structure, where one channel is filled with raw semen and the other with pure buffer. The semen sample was allowed to reach equilibrium in both chambers, whereas non-motile sperms remained in the original channel, and roughly half of the motile sperms would swim across the phase-guide barrier into the buffer channel. Sperms in each channel agglomerated into pellets after centrifugation, with the corresponding area representing total and motile sperm concentrations. Total sperm concentration up to 10(8) sperms per ml and motile percentage in the range of 10-70% were tested, encompassing the cutoff value of 40% stated by World Health Organization standards. Results from patient samples show compact and robust pellets after centrifugation. Comparison of total sperm concentration between the microfluidic device and the Makler chamber reveal they agree within 5% and show strong correlation, with a coefficient of determination of R(2) = 0.97. Motile sperm count between the microfluidic device and the Makler chamber agrees within 5%, with a coefficient of determination of R(2) = 0.84. Comparison of results from the Makler Chamber, sperm quality analyzer, and the microfluidic device revealed that results from the microfluidic device agree well with the Makler chamber. The sperm microfluidic chip analyzes both total and motile sperm concentrations in one spin, is accurate and easy to use, and should enable sperm quality analysis with ease.

  4. Teachers' Knowledge and Readiness towards Implementation of School Based Assessment in Secondary Schools

    Science.gov (United States)

    Veloo, Arsaythamby; Krishnasamy, Hariharan N.; Md-Ali, Ruzlan

    2015-01-01

    School-Based Assessment (SBA) was implemented in Malaysian secondary schools in 2012. Since its implementation, teachers have faced several challenges to meet the aims and objectives of the School-Based Assessment. Based on these challenges this study aims to find the level of teachers' knowledge and readiness towards the implementation of…

  5. Implementing an Assessment Clinic in a Residential PTSD Program

    Directory of Open Access Journals (Sweden)

    Joan McDowell

    2014-08-01

    Full Text Available Creating useful treatment plans can help improve services to consumers of mental health services. As more evidence-based practices are implemented, deciding what treatment, at what time, for whom becomes an important factor in facilitating positive outcomes. Readiness for trauma-focused treatments for Posttraumatic Stress Disorder (PTSD such as Cognitive Processing Therapy or Prolonged Exposure Therapy may influence whether an individual can successfully complete either protocol. In addition, components of adjunctive therapies such as Acceptance and Commitment Therapy or Dialectical Behavior Therapy may be useful in moving a particular patient toward readiness and successful completion of treatment. Psychological assessment adds valuable data to inform these types of treatment decisions. This paper describes the implementation of a psychological assessment clinic in a residential PTSD treatment setting. Barriers to implementation, use of the data, and Veterans’ reactions to the feedback provided to them are included.

  6. The family assessment device: an update.

    Science.gov (United States)

    Mansfield, Abigail K; Keitner, Gabor I; Dealy, Jennifer

    2015-03-01

    The current study set out to describe family functioning scores of a contemporary community sample, using the Family Assessment Device (FAD), and to compare this to a currently help-seeking sample. The community sample consisted of 151 families who completed the FAD. The help-seeking sample consisted of 46 families who completed the FAD at their first family therapy appointment as part of their standard care at an outpatient family therapy clinic at an urban hospital. Findings suggest that FAD means from the contemporary community sample indicate satisfaction with family functioning, while FAD scores from the help-seeking sample indicate dissatisfaction with family functioning. In addition, the General Functioning scale of the FAD continues to correlate highly with all other FAD scales, except Behavior Control. The cut-off scores for the FAD indicating satisfaction or dissatisfaction by family members with their family functioning continue to be relevant and the FAD continues to be a useful tool to assess family functioning in both clinical and research contexts. © 2014 Family Process Institute.

  7. An Assessment of the Implementation of Guidance and Counselling ...

    African Journals Online (AJOL)

    This paper is based on a research study carried out by the author in 2003. The study assessed how Guidance and Counselling Programmes were being implemented in Gweru urban secondary schools at Ordinary level. The assessment focused on such key elements in Guidance and Counselling as time allocation, ...

  8. A framework for risk assessment on lean production implementation

    Directory of Open Access Journals (Sweden)

    Giuliano Almeida Marodin

    2014-02-01

    Full Text Available The organizational and technical complexity of implementing the lean principles and practices can become an extensively time consuming journey with few benefits. We argue that risk assessment can aid on the understanding and management of the major difficulties on the Lean production implementation (LPI. Thus, this paper proposes a framework for risk assessment on the LPI process. The literature review permitted to adapt the risk assessment steps to the characteristics of the LPI and develop data collection and analysis procedures for each step. The Sociotechnical systems (STS theory was brought in to improve the understanding of the context’s characteristics on the proposed framework because it has a major influence on the LPI. The framework was has five steps: (a defining the unit of analysis; (b describing the context; (c risk identification; (d risk analysis; and (e risk relationships modeling.

  9. Power Approaches for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Achraf Ben Amar

    2015-11-01

    Full Text Available Implantable medical devices have been implemented to provide treatment and to assess in vivo physiological information in humans as well as animal models for medical diagnosis and prognosis, therapeutic applications and biological science studies. The advances of micro/nanotechnology dovetailed with novel biomaterials have further enhanced biocompatibility, sensitivity, longevity and reliability in newly-emerged low-cost and compact devices. Close-loop systems with both sensing and treatment functions have also been developed to provide point-of-care and personalized medicine. Nevertheless, one of the remaining challenges is whether power can be supplied sufficiently and continuously for the operation of the entire system. This issue is becoming more and more critical to the increasing need of power for wireless communication in implanted devices towards the future healthcare infrastructure, namely mobile health (m-Health. In this review paper, methodologies to transfer and harvest energy in implantable medical devices are introduced and discussed to highlight the uses and significances of various potential power sources.

  10. Exploring a new security framework for remote patient monitoring devices

    OpenAIRE

    Ondiege, Brian; Clarke, Macolm; Mapp, Glenford E.

    2017-01-01

    Security has been an issue of contention in healthcare. The lack of familiarity and poor implementation of security in healthcare leave the patients’ data vulnerable to attackers. The main issue is assessing how we can provide security in an RPM infrastructure. The findings in literature show there is little empirical evidence on proper implementation of security. Therefore, there is an urgent need in addressing cybersecurity issues in medical devices. Through the review of relevant literatur...

  11. The validity of visual acuity assessment using mobile technology devices in the primary care setting.

    Science.gov (United States)

    O'Neill, Samuel; McAndrew, Darryl J

    2016-04-01

    The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.

  12. Spacelab Mission Implementation Cost Assessment (SMICA)

    Science.gov (United States)

    Guynes, B. V.

    1984-01-01

    A total savings of approximately 20 percent is attainable if: (1) mission management and ground processing schedules are compressed; (2) the equipping, staffing, and operating of the Payload Operations Control Center is revised, and (3) methods of working with experiment developers are changed. The development of a new mission implementation technique, which includes mission definition, experiment development, and mission integration/operations, is examined. The Payload Operations Control Center is to relocate and utilize new computer equipment to produce cost savings. Methods of reducing costs by minimizing the Spacelab and payload processing time during pre- and post-mission operation at KSC are analyzed. The changes required to reduce costs in the analytical integration process are studied. The influence of time, requirements accountability, and risk on costs is discussed. Recommendation for cost reductions developed by the Spacelab Mission Implementation Cost Assessment study are listed.

  13. Validity of Devices That Assess Body Temperature During Outdoor Exercise in the Heat

    Science.gov (United States)

    Casa, Douglas J; Becker, Shannon M; Ganio, Matthew S; Brown, Christopher M; Yeargin, Susan W; Roti, Melissa W; Siegler, Jason; Blowers, Julie A; Glaviano, Neal R; Huggins, Robert A; Armstrong, Lawrence E; Maresh, Carl M

    2007-01-01

    Context: Rectal temperature is recommended by the National Athletic Trainers' Association as the criterion standard for recognizing exertional heat stroke, but other body sites commonly are used to measure temperature. Few authors have assessed the validity of the thermometers that measure body temperature at these sites in athletic settings. Objective: To assess the validity of commonly used temperature devices at various body sites during outdoor exercise in the heat. Design: Observational field study. Setting: Outdoor athletic facilities. Patients or Other Participants: Fifteen men and 10 women (age = 26.5 ± 5.3 years, height = 174.3 ± 11.1 cm, mass = 72.73 ± 15.95 kg, body fat = 16.2 ± 5.5%). Intervention(s): We simultaneously tested inexpensive and expensive devices orally and in the axillary region, along with measures of aural, gastrointestinal, forehead, temporal, and rectal temperatures. Temporal temperature was measured according to the instruction manual and a modified method observed in medical tents at local road races. We also measured forehead temperatures directly on the athletic field (other measures occurred in a covered pavilion) where solar radiation was greater. Rectal temperature was the criterion standard used to assess the validity of all other devices. Subjects' temperatures were measured before exercise, every 60 minutes during 180 minutes of exercise, and every 20 minutes for 60 minutes of postexercise recovery. Temperature devices were considered invalid if the mean bias (average difference between rectal temperature and device temperature) was greater than ±0.27°C (±0.5°F). Main Outcome Measure(s): Temperature from each device at each site and time point. Results: Mean bias for the following temperatures was greater than the allowed limit of ±0.27°C (±0.5°F): temperature obtained via expensive oral device (−1.20°C [−2.17°F]), inexpensive oral device (−1.67°C [−3.00°F]), expensive axillary device (−2.58°C [−4

  14. The Implementations and Challenges of Continuous Assessment in Public Universities of Eastern Ethiopia

    Directory of Open Access Journals (Sweden)

    Gemechu Abera

    2017-11-01

    Full Text Available The study was aimed to investigate the implementations and challenges of continuous assessment in selected Public Universities of Eastern Ethiopia. Descriptive survey research design was employed to carry out this study because it is used to describe the characteristics of a given population in a systematic and accurate fashion. Stratified random sampling technique was employed to collect pertinent information from the respondents through questionnaire and observational checklists. To make the interpretation of the findings easier, the researchers used both descriptive and inferential statistics. The first finding was that almost the implementations of continuous assessment in these selected universities were very poor. The second finding was that there was statistically a significant mean difference among these public universities in utilizing and implementing continuous assessment; the third finding was that there was statistically significant mean difference among these sampled respondents in implementing the three domains of educational objectives; the fourth interesting finding was that the implemented continuous assessment type was highly dominated by cognitive, followed by affective and then psychomotor domains respectively. Finally, it was recommended that instructors should implement continuous assessment not only for the sake of evaluating and marking students’ result but also for the sake of learning skills and practices.

  15. Implementation. Improving caries detection, assessment, diagnosis and monitoring.

    Science.gov (United States)

    Pitts, N B

    2009-01-01

    This chapter deals with improving the detection, assessment, diagnosis and monitoring of caries to ensure optimal personalized caries management. This can be achieved by delivering what we have (synthesized evidence and international consensus) better and more consistently, as well as driving research and innovation in the areas where we need them. There is a need to better understand the interrelated pieces of the jigsaw that makes up evidence-based dentistry, i.e. the linkages between (a) research and synthesis, (b) dissemination of research results and (c) the implementation of research findings which should ensure that research findings change practice at the clinician-patient level. The current situation is outlined; it is at the implementation step where preventive caries control seems to have failed in some countries but not others. Opportunities for implementation include: capitalizing on the World Health Organization's global policy for improvement of oral health, which sets out an action plan for health promotion and integrated disease prevention; utilizing the developments around the International Caries Detection and Assessment System wardrobe of options and e-learning; building on initiatives from the International Dental Federation and the American Dental Association and linking these to patients' preferences, the wider moves to wellbeing and health maintenance. Challenges for implementation include the slow pace of evolution around dental remuneration systems and some groups of dentists failing to embrace clinical prevention. In the future, implementation of current and developing evidence should be accompanied by research into getting research findings into routine practice, with impacts on the behaviour of patients, professionals and policy makers. Copyright 2009 S. Karger AG, Basel

  16. Study on data compression algorithm and its implementation in portable electronic device for Internet of Things applications

    Directory of Open Access Journals (Sweden)

    Khairi Nor Asilah

    2017-01-01

    Full Text Available An Internet of Things (IoT device is usually powered by a small battery, which does not last long. As a result, saving energy in IoT devices has become an important issue when it comes to this subject. Since power consumption is the primary cause of radio communication, some researchers have proposed several compression algorithms with the purpose of overcoming this particular problem. Several data compression algorithms from previous reference papers are discussed in this paper. The description of the compression algorithm in the reference papers was collected and summarized in a table form. From the analysis, MAS compression algorithm was selected as a project prototype due to its high potential for meeting the project requirements. Besides that, it also produced better performance regarding energy-saving, better memory usage, and data transmission efficiency. This method is also suitable to be implemented in WSN. MAS compression algorithm will be prototyped and applied in portable electronic devices for Internet of Things applications.

  17. Study on data compression algorithm and its implementation in portable electronic device for Internet of Things applications

    Science.gov (United States)

    Asilah Khairi, Nor; Bahari Jambek, Asral

    2017-11-01

    An Internet of Things (IoT) device is usually powered by a small battery, which does not last long. As a result, saving energy in IoT devices has become an important issue when it comes to this subject. Since power consumption is the primary cause of radio communication, some researchers have proposed several compression algorithms with the purpose of overcoming this particular problem. Several data compression algorithms from previous reference papers are discussed in this paper. The description of the compression algorithm in the reference papers was collected and summarized in a table form. From the analysis, MAS compression algorithm was selected as a project prototype due to its high potential for meeting the project requirements. Besides that, it also produced better performance regarding energy-saving, better memory usage, and data transmission efficiency. This method is also suitable to be implemented in WSN. MAS compression algorithm will be prototyped and applied in portable electronic devices for Internet of Things applications.

  18. DIFFERENCES IN MANAGER ASSESSMENTS OF ISO 14000 STANDARD IMPLEMENTATION IN TURKEY

    Directory of Open Access Journals (Sweden)

    Sıtkı Gözlü

    2005-12-01

    Full Text Available This study reports the results of a survey about the improvements achieved as result of ISO 14000 Environmental Management System (EMS standard implementation and the differences of improvements with respect to firm characteristics. A survey has been conducted in order to explain the improvements related to environmental management process and overall firm performance. The survey involved sixty-six enterprises implementing ISO 14000 EMS standard in Turkey. In order to assess improvements obtained from ISO 14000 EMS implementation, statements related to environmental management process and overall firm performance indicators have been prepared. The statements in this study are relevant to previous research. A factor analysis was employed to determine the factors of the variables explaining improvements. Nine factors have been identified related to achieved improvements, such as establishment of pro-active environmental management system, effectiveness in resource utilization, effectiveness of process control, relationships with industry and government, meeting expectations of stakeholders, demonstration of social responsibility, profitability, productivity, and competitiveness. Then, a T- test was conducted to determine the differences of managers’ assessments with respect to certain firm characteristics. The findings have shown that there are differences in the assessments of improvements achieved as a result of ISO 14000 EMS standard implementation with respect to sales volume, foreign-capital possession, and ISO 14000 EMS standard implementation. On the other hand, industrial sector, age of establishment, and export orientation are not statistically significant for the differences in the assessments of improvements.

  19. Design, Development and Implementation of a Smartphone Overdependence Management System for the Self-Control of Smart Devices

    OpenAIRE

    Seo-Joon Lee; Mi Jung Rho; In Hye Yook; Seung-Ho Park; Kwang-Soo Jang; Bum-Joon Park; Ook Lee; Dong Kyun Lee; Dai-Jin Kim; In Young Choi

    2016-01-01

    Background: Smartphone overdependence is a type of mental disorder that requires continuous treatment for cure and prevention. A smartphone overdependence management system that is based on scientific evidence is required. This study proposes the design, development and implementation of a smartphone overdependence management system for self-control of smart devices. Methods: The system architecture of the Smartphone Overdependence Management System (SOMS) primarily consists of four sessions ...

  20. Formative assessment in undergraduate medical education: concept, implementation and hurdles.

    Science.gov (United States)

    Rauf, Ayesha; Shamim, Muhammad Shahid; Aly, Syed Moyn; Chundrigar, Tariq; Alam, Shams Nadeem

    2014-01-01

    Formative assessment, described as "the process of appraising, judging or evaluating students' work or performance and using this to shape and improve students' competence", is generally missing from medical schools of Pakistan. Progressive institutions conduct "formative assessment" as a fleeting part of the curriculum by using various methods that may or may not include feedback to learners. The most important factor in the success of formative assessment is the quality of feedback, shown to have the maximum impact on student accomplishment. Inclusion of formative assessment into the curriculum and its implementation will require the following: Enabling Environment, Faculty and student Training, Role of Department of Medical Education (DME). Many issues can be predicted that may jeopardize the effectiveness of formative assessment including faculty resistance, lack of motivation from students and faculty and paucity of commitment from the top administration. For improvement in medical education in Pakistan, we need to develop a system considered worthy by national and international standards. This paper will give an overview of formative assessment, its implications and recommendations for implementation in medical institutes of Pakistan.

  1. Assessment on the impact of plasma television implementation on ...

    African Journals Online (AJOL)

    Assessment on the impact of plasma television implementation on the teaching learning process of mathematics class: the case on selected practicum sites (high schools) for education faculty of Jimma University.

  2. Implementation of a low-cost mobile devices to support medical diagnosis.

    Science.gov (United States)

    García Sánchez, Carlos; Botella Juan, Guillermo; Ayuso Márquez, Fermín; González Rodríguez, Diego; Prieto-Matías, Manuel; Tirado Fernández, Francisco

    2013-01-01

    Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  3. Implementation of a Low-Cost Mobile Devices to Support Medical Diagnosis

    Directory of Open Access Journals (Sweden)

    Carlos García Sánchez

    2013-01-01

    Full Text Available Medical imaging has become an absolutely essential diagnostic tool for clinical practices; at present, pathologies can be detected with an earliness never before known. Its use has not only been relegated to the field of radiology but also, increasingly, to computer-based imaging processes prior to surgery. Motion analysis, in particular, plays an important role in analyzing activities or behaviors of live objects in medicine. This short paper presents several low-cost hardware implementation approaches for the new generation of tablets and/or smartphones for estimating motion compensation and segmentation in medical images. These systems have been optimized for breast cancer diagnosis using magnetic resonance imaging technology with several advantages over traditional X-ray mammography, for example, obtaining patient information during a short period. This paper also addresses the challenge of offering a medical tool that runs on widespread portable devices, both on tablets and/or smartphones to aid in patient diagnostics.

  4. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  5. Implementation of health impact assessment in Danish municipal context

    DEFF Research Database (Denmark)

    Kraemer, Stella R. J.; Nikolajsen, Louise Theilgaard; Gulis, Gabriel

    2014-01-01

    . Conclusions: Systematic and sustainable capacity building is needed to achieve high level implementation of HIA in Danish municipalities. Development of validated tools, most importantly screening tools with focus on priorities of national public health policy would enhance implementation on municipal level.......Aims: Implementation of Health Impact Assessment (HIA) in Danish municipalities has been analyzed using the Roger's Diffusion of Innovation Theory. Municipalities were chosen from among those who presented their health policies on websites according to the status of inclusion of HIA into health...... policy. Methods: Qualitative interviews were conducted in 6 municipalities (3 with HIA inducted in their health policy and 3 without it) gathering information on knowledge and attitudes to HIA, barriers to its implementation, social system and communication channels used or expected to be used...

  6. Implementation of continuous-variable quantum key distribution with composable and one-sided-device-independent security against coherent attacks.

    Science.gov (United States)

    Gehring, Tobias; Händchen, Vitus; Duhme, Jörg; Furrer, Fabian; Franz, Torsten; Pacher, Christoph; Werner, Reinhard F; Schnabel, Roman

    2015-10-30

    Secret communication over public channels is one of the central pillars of a modern information society. Using quantum key distribution this is achieved without relying on the hardness of mathematical problems, which might be compromised by improved algorithms or by future quantum computers. State-of-the-art quantum key distribution requires composable security against coherent attacks for a finite number of distributed quantum states as well as robustness against implementation side channels. Here we present an implementation of continuous-variable quantum key distribution satisfying these requirements. Our implementation is based on the distribution of continuous-variable Einstein-Podolsky-Rosen entangled light. It is one-sided device independent, which means the security of the generated key is independent of any memoryfree attacks on the remote detector. Since continuous-variable encoding is compatible with conventional optical communication technology, our work is a step towards practical implementations of quantum key distribution with state-of-the-art security based solely on telecom components.

  7. Implementation of continuous-variable quantum key distribution with composable and one-sided-device-independent security against coherent attacks

    Science.gov (United States)

    Gehring, Tobias; Händchen, Vitus; Duhme, Jörg; Furrer, Fabian; Franz, Torsten; Pacher, Christoph; Werner, Reinhard F.; Schnabel, Roman

    2015-10-01

    Secret communication over public channels is one of the central pillars of a modern information society. Using quantum key distribution this is achieved without relying on the hardness of mathematical problems, which might be compromised by improved algorithms or by future quantum computers. State-of-the-art quantum key distribution requires composable security against coherent attacks for a finite number of distributed quantum states as well as robustness against implementation side channels. Here we present an implementation of continuous-variable quantum key distribution satisfying these requirements. Our implementation is based on the distribution of continuous-variable Einstein-Podolsky-Rosen entangled light. It is one-sided device independent, which means the security of the generated key is independent of any memoryfree attacks on the remote detector. Since continuous-variable encoding is compatible with conventional optical communication technology, our work is a step towards practical implementations of quantum key distribution with state-of-the-art security based solely on telecom components.

  8. Assessing the Expected Value of Research Studies in Reducing Uncertainty and Improving Implementation Dynamics.

    Science.gov (United States)

    Grimm, Sabine E; Dixon, Simon; Stevens, John W

    2017-07-01

    With low implementation of cost-effective health technologies being a problem in many health systems, it is worth considering the potential effects of research on implementation at the time of health technology assessment. Meaningful and realistic implementation estimates must be of dynamic nature. To extend existing methods for assessing the value of research studies in terms of both reduction of uncertainty and improvement in implementation by considering diffusion based on expert beliefs with and without further research conditional on the strength of evidence. We use expected value of sample information and expected value of specific implementation measure concepts accounting for the effects of specific research studies on implementation and the reduction of uncertainty. Diffusion theory and elicitation of expert beliefs about the shape of diffusion curves inform implementation dynamics. We illustrate use of the resulting dynamic expected value of research in a preterm birth screening technology and results are compared with those from a static analysis. Allowing for diffusion based on expert beliefs had a significant impact on the expected value of research in the case study, suggesting that mistakes are made where static implementation levels are assumed. Incorporating the effects of research on implementation resulted in an increase in the expected value of research compared to the expected value of sample information alone. Assessing the expected value of research in reducing uncertainty and improving implementation dynamics has the potential to complement currently used analyses in health technology assessments, especially in recommendations for further research. The combination of expected value of research, diffusion theory, and elicitation described in this article is an important addition to the existing methods of health technology assessment.

  9. A Systematic Review on Existing Measures for the Subjective Assessment of Rehabilitation and Assistive Robot Devices

    Directory of Open Access Journals (Sweden)

    Yiannis Koumpouros

    2016-01-01

    Full Text Available The objective of the current study is to identify and classify outcome measures currently used for the assessment of rehabilitation or assistive robot devices. We conducted a systematic review of the literature using PubMed, MEDLINE, CIRRIE, and Scopus databases for studies that assessed rehabilitation or assistive robot devices from 1980 through January 2016. In all, 31 articles met all inclusion criteria. Tailor-made questionnaires were the most commonly used tool at 66.7%, while the great majority (93.9% of the studies used nonvalidated instruments. The study reveals the absence of a standard scale which makes it difficult to compare the results from different researchers. There is a great need, therefore, for a valid and reliable instrument to be available for use by the intended end users for the subjective assessment of robot devices. The study concludes by identifying two scales that have been validated in general assistive technology devices and could support the scope of subjective assessment in rehabilitation or assistive robots (however, with limited coverage and a new one called PYTHEIA, recently published. The latter intends to close the gap and help researchers and developers to evaluate, assess, and produce products that satisfy the real needs of the end users.

  10. Device interoperability and authentication for telemedical appliance based on the ISO/IEEE 11073 Personal Health Device (PHD) Standards.

    Science.gov (United States)

    Caranguian, Luther Paul R; Pancho-Festin, Susan; Sison, Luis G

    2012-01-01

    In this study, we focused on the interoperability and authentication of medical devices in the context of telemedical systems. A recent standard called the ISO/IEEE 11073 Personal Health Device (X73-PHD) Standards addresses the device interoperability problem by defining common protocols for agent (medical device) and manager (appliance) interface. The X73-PHD standard however has not addressed security and authentication of medical devices which is important in establishing integrity of a telemedical system. We have designed and implemented a security policy within the X73-PHD standards. The policy will enable device authentication using Asymmetric-Key Cryptography and the RSA algorithm as the digital signature scheme. We used two approaches for performing the digital signatures: direct software implementation and use of embedded security modules (ESM). The two approaches were evaluated and compared in terms of execution time and memory requirement. For the standard 2048-bit RSA, ESM calculates digital signatures only 12% of the total time for the direct implementation. Moreover, analysis shows that ESM offers more security advantage such as secure storage of keys compared to using direct implementation. Interoperability with other systems was verified by testing the system with LNI Healthlink, a manager software that implements the X73-PHD standard. Lastly, security analysis was done and the system's response to common attacks on authentication systems was analyzed and several measures were implemented to protect the system against them.

  11. Assessing organizational readiness for depression care quality improvement: relative commitment and implementation capability.

    Science.gov (United States)

    Rubenstein, Lisa V; Danz, Marjorie S; Crain, A Lauren; Glasgow, Russell E; Whitebird, Robin R; Solberg, Leif I

    2014-12-02

    Depression is a major cause of morbidity and cost in primary care patient populations. Successful depression improvement models, however, are complex. Based on organizational readiness theory, a practice's commitment to change and its capability to carry out the change are both important predictors of initiating improvement. We empirically explored the links between relative commitment (i.e., the intention to move forward within the following year) and implementation capability. The DIAMOND initiative administered organizational surveys to medical and quality improvement leaders from each of 83 primary care practices in Minnesota. Surveys preceded initiation of activities directed at implementation of a collaborative care model for improving depression care. To assess implementation capability, we developed composites of survey items for five types of organizational factors postulated to be collaborative care barriers and facilitators. To assess relative commitment for each practice, we averaged leader ratings on an identical survey question assessing practice priorities. We used multivariable regression analyses to assess the extent to which implementation capability predicted relative commitment. We explored whether relative commitment or implementation capability measures were associated with earlier initiation of DIAMOND improvements. All five implementation capability measures independently predicted practice leaders' relative commitment to improving depression care in the following year. These included the following: quality improvement culture and attitudes (p = 0.003), depression culture and attitudes (p commitment (p = 0.002) and prior depression quality improvement activities appeared to be associated with earlier participation in the DIAMOND initiative. The study supports the concept of organizational readiness to improve quality of care and the use of practice leader surveys to assess it. Practice leaders' relative commitment to depression care

  12. 76 FR 37119 - Development of Best Practices for Community Health Needs Assessment and Implementation Strategy...

    Science.gov (United States)

    2011-06-24

    ... Best Practices for Community Health Needs Assessment and Implementation Strategy; Public Forum AGENCY... processes relating to community health needs assessment (CHNA) and implementation strategy/plan development... practices in CHNA and implementation strategy development and execution for improved community health...

  13. Compute-unified device architecture implementation of a block-matching algorithm for multiple graphical processing unit cards.

    Science.gov (United States)

    Massanes, Francesc; Cadennes, Marie; Brankov, Jovan G

    2011-07-01

    In this paper we describe and evaluate a fast implementation of a classical block matching motion estimation algorithm for multiple Graphical Processing Units (GPUs) using the Compute Unified Device Architecture (CUDA) computing engine. The implemented block matching algorithm (BMA) uses summed absolute difference (SAD) error criterion and full grid search (FS) for finding optimal block displacement. In this evaluation we compared the execution time of a GPU and CPU implementation for images of various sizes, using integer and non-integer search grids.The results show that use of a GPU card can shorten computation time by a factor of 200 times for integer and 1000 times for a non-integer search grid. The additional speedup for non-integer search grid comes from the fact that GPU has built-in hardware for image interpolation. Further, when using multiple GPU cards, the presented evaluation shows the importance of the data splitting method across multiple cards, but an almost linear speedup with a number of cards is achievable.In addition we compared execution time of the proposed FS GPU implementation with two existing, highly optimized non-full grid search CPU based motion estimations methods, namely implementation of the Pyramidal Lucas Kanade Optical flow algorithm in OpenCV and Simplified Unsymmetrical multi-Hexagon search in H.264/AVC standard. In these comparisons, FS GPU implementation still showed modest improvement even though the computational complexity of FS GPU implementation is substantially higher than non-FS CPU implementation.We also demonstrated that for an image sequence of 720×480 pixels in resolution, commonly used in video surveillance, the proposed GPU implementation is sufficiently fast for real-time motion estimation at 30 frames-per-second using two NVIDIA C1060 Tesla GPU cards.

  14. DEFINING THE RELEVANT OUTCOME MEASURES IN MEDICAL DEVICE ASSESSMENTS: AN ANALYSIS OF THE DEFINITION PROCESS IN HEALTH TECHNOLOGY ASSESSMENT.

    Science.gov (United States)

    Jacobs, Esther; Antoine, Sunya-Lee; Prediger, Barbara; Neugebauer, Edmund; Eikermann, Michaela

    2017-01-01

    Defining relevant outcome measures for clinical trials on medical devices (MD) is complex, as there is a large variety of potentially relevant outcomes. The chosen outcomes vary widely across clinical trials making the assessment in evidence syntheses very challenging. The objective is to provide an overview on the current common procedures of health technology assessment (HTA) institutions in defining outcome measures in MD trials. In 2012-14, the Web pages of 126 institutions involved in HTA were searched for methodological manuals written in English or German that describe methods for the predefinition process of outcome measures. Additionally, the institutions were contacted by email. Relevant information was extracted. All process steps were performed independently by two reviewers. Twenty-four manuals and ten responses from the email request were included in the analysis. Overall, 88.5 percent of the institutions describe the type of outcomes that should be considered in detail and 84.6 percent agree that the main focus should be on patient relevant outcomes. Specifically related to MD, information could be obtained in 26 percent of the included manuals and email responses. Eleven percent of the institutions report a particular consideration of MD related outcomes. This detailed analysis on common procedures of HTA institutions in the context of defining relevant outcome measures for the assessment of MD shows that standardized procedures for MD from the perspective of HTA institutions are not widespread. This leads to the question if a homogenous approach should be implemented in the field of HTA on MD.

  15. Design, Implementation & Assessment of Local Exhaust Ventilation System and dust collectors for crushing unit

    Directory of Open Access Journals (Sweden)

    Farshid Ghorbani shahna

    2015-09-01

    Full Text Available Background & objective: Industrial ventilation systems and dust collectors are effective solutions to reduce particulate emissions in the workplace and environmental in mineral processes. In this study, Local Exhaust Ventilation System and dust collectors for control of emitted silica, coke, silicon carbide dusts from crushing unit was designed and evaluated. Methods: : Local Exhaust ventilation system based on standards and guides was designed and implemented after field study of the processes and sources of air pollutants. A set comprised of the four parallel cyclones (Stairmand model and a new design of the scrubber had been used for dust control. After set-up of systems, its effectiveness in reducing the exposure of workers in the workshops and dust collecting were assessed. Results: Test results were significant differences between the concentration of particles in both on and off the ventilation system revealed (P <0.05. The system has been implemented as means of personal exposure to pollutants and environmental emissions were reduced 93.01% and 64.64%, respectively. Also, alone and integrated collection efficiency of cyclone and scrubber, were 94.2%, 59.05% and 97.4%, respectively. The results show good agreement with the values of the parameters ventilation system was designed. Conclusion: Implementation of integrated dust collectors is a good option in industries that have the financial and technical constraints to improve change processes and devices. This method with attainment to health and environmental standards not only can be resolve of the pollution problems, but also will be economically justified of such projects with reduction of depreciation expense and dust recycling.

  16. Agency Leaders' Assessments of Feasibility and Desirability of Implementation of Evidence-Based Practices in Youth-Serving Organizations Using the Stages of Implementation Completion

    Directory of Open Access Journals (Sweden)

    Lawrence A. Palinkas

    2018-05-01

    Full Text Available Background: This study examined influences on the decisions of administrators of youth-serving organizations to initiate and proceed with implementation of an evidence-based practice (EBP.Methods: Semi-structured interviews, developed using the Stages of Implementation Completion (SIC as a framework, were conducted with 19 agency chief executive officers and program directors of 15 organizations serving children and adolescents.Results: Agency leaders' self-assessments of implementation feasibility and desirability prior to implementation (Pre-implementation were influenced by intervention affordability, feasibility, requirements, validity, reliability, relevance, cost savings, positive outcomes, and adequacy of information; availability of funding, support from sources external to the agency, and adequacy of technical assistance; and staff availability and attitudes toward innovation in general and EBPs in particular, organizational capacity, fit between the EBP and agency mission and capacity, prior experience with implementation, experience with seeking evidence, and developing consensus. Assessments during the Implementation phase included intervention flexibility and requirements; availability of funding, adequacy of training and technical assistance, and getting sufficient and appropriate referrals; and staffing and implementing with fidelity. Assessments during the Sustainment phase included intervention costs and benefits; availability of funding, support from sources outside of the agency, and need for the EBP; and the fit between the EBP and the agency mission.Discussion: The results point to opportunities for using agency leader models to develop strategies to facilitate implementation of evidence-based and innovative practices for children and adolescents. The SIC provides a standardized framework for guiding agency leader self-assessments of implementation.

  17. Agency Leaders' Assessments of Feasibility and Desirability of Implementation of Evidence-Based Practices in Youth-Serving Organizations Using the Stages of Implementation Completion.

    Science.gov (United States)

    Palinkas, Lawrence A; Campbell, Mark; Saldana, Lisa

    2018-01-01

    Background: This study examined influences on the decisions of administrators of youth-serving organizations to initiate and proceed with implementation of an evidence-based practice (EBP). Methods: Semi-structured interviews, developed using the Stages of Implementation Completion (SIC) as a framework, were conducted with 19 agency chief executive officers and program directors of 15 organizations serving children and adolescents. Results: Agency leaders' self-assessments of implementation feasibility and desirability prior to implementation (Pre-implementation) were influenced by intervention affordability, feasibility, requirements, validity, reliability, relevance, cost savings, positive outcomes, and adequacy of information; availability of funding, support from sources external to the agency, and adequacy of technical assistance; and staff availability and attitudes toward innovation in general and EBPs in particular, organizational capacity, fit between the EBP and agency mission and capacity, prior experience with implementation, experience with seeking evidence, and developing consensus. Assessments during the Implementation phase included intervention flexibility and requirements; availability of funding, adequacy of training and technical assistance, and getting sufficient and appropriate referrals; and staffing and implementing with fidelity. Assessments during the Sustainment phase included intervention costs and benefits; availability of funding, support from sources outside of the agency, and need for the EBP; and the fit between the EBP and the agency mission. Discussion: The results point to opportunities for using agency leader models to develop strategies to facilitate implementation of evidence-based and innovative practices for children and adolescents. The SIC provides a standardized framework for guiding agency leader self-assessments of implementation.

  18. Effects of a strategy to improve offender assessment practices: Staff perceptions of implementation outcomes.

    Science.gov (United States)

    Welsh, Wayne N; Lin, Hsiu-Ju; Peters, Roger H; Stahler, Gerald J; Lehman, Wayne E K; Stein, Lynda A R; Monico, Laura; Eggers, Michele; Abdel-Salam, Sami; Pierce, Joshua C; Hunt, Elizabeth; Gallagher, Colleen; Frisman, Linda K

    2015-07-01

    This implementation study examined the impact of an organizational process improvement intervention (OPII) on a continuum of evidence based practices related to assessment and community reentry of drug-involved offenders: Measurement/Instrumentation, Case Plan Integration, Conveyance/Utility, and Service Activation/Delivery. To assess implementation outcomes (staff perceptions of evidence-based assessment practices), a survey was administered to correctional and treatment staff (n=1509) at 21 sites randomly assigned to an Early- or Delayed-Start condition. Hierarchical linear models with repeated measures were used to examine changes in evidence-based assessment practices over time, and organizational characteristics were examined as covariates to control for differences across the 21 research sites. Results demonstrated significant intervention and sustainability effects for three of the four assessment domains examined, although stronger effects were obtained for intra- than inter-agency outcomes. No significant effects were found for Conveyance/Utility. Implementation interventions such as the OPII represent an important tool to enhance the use of evidence-based assessment practices in large and diverse correctional systems. Intra-agency assessment activities that were more directly under the control of correctional agencies were implemented most effectively. Activities in domains that required cross-systems collaboration were not as successfully implemented, although longer follow-up periods might afford detection of stronger effects. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Attacks on the Network Synchronization Systems Counteraction Method Implemented in the Software and Hardware Device «MARSH! 3.0»

    Directory of Open Access Journals (Sweden)

    Dmitry Anatolevich Melnikov

    2013-12-01

    Full Text Available This paper proposes attacks on the network synchronization systems counteraction technique, method, algorithm and realizable aspects. The network synchronization systems are included in information technology systems or networks. This method is implemented in software and hardware device (means «MARSH! 3.0» providing trusted session.

  20. Dietary assessment and self-monitoring with nutrition applications for mobile devices.

    Science.gov (United States)

    Lieffers, Jessica R L; Hanning, Rhona M

    2012-01-01

    Nutrition applications for mobile devices (e.g., personal digital assistants, smartphones) are becoming increasingly accessible and can assist with the difficult task of intake recording for dietary assessment and self-monitoring. This review is a compilation and discussion of research on this tool for dietary intake documentation in healthy populations and those trying to lose weight. The purpose is to compare this tool with conventional methods (e.g., 24-hour recall interviews, paper-based food records). Research databases were searched from January 2000 to April 2011, with the following criteria: healthy or weight loss populations, use of a mobile device nutrition application, and inclusion of at least one of three measures, which were the ability to capture dietary intake in comparison with conventional methods, dietary self-monitoring adherence, and changes in anthropometrics and/or dietary intake. Eighteen studies are discussed. Two application categories were identified: those with which users select food and portion size from databases and those with which users photograph their food. Overall, positive feedback was reported with applications. Both application types had moderate to good correlations for assessing energy and nutrient intakes in comparison with conventional methods. For self-monitoring, applications versus conventional techniques (often paper records) frequently resulted in better self-monitoring adherence, and changes in dietary intake and/or anthropometrics. Nutrition applications for mobile devices have an exciting potential for use in dietetic practice.

  1. Control protocol: large scale implementation at the CERN PS complex - a first assessment

    International Nuclear Information System (INIS)

    Abie, H.; Benincasa, G.; Coudert, G.; Davydenko, Y.; Dehavay, C.; Gavaggio, R.; Gelato, G.; Heinze, W.; Legras, M.; Lustig, H.; Merard, L.; Pearson, T.; Strubin, P.; Tedesco, J.

    1994-01-01

    The Control Protocol is a model-based, uniform access procedure from a control system to accelerator equipment. It was proposed at CERN about 5 years ago and prototypes were developed in the following years. More recently, this procedure has been finalized and implemented at a large scale in the PS Complex. More than 300 pieces of equipment are now using this protocol in normal operation and another 300 are under implementation. These include power converters, vacuum systems, beam instrumentation devices, RF equipment, etc. This paper describes how the single general procedure is applied to the different kinds of equipment. The advantages obtained are also discussed. ((orig.))

  2. [Hospital-based health technology assessment in France: how to proceed to evaluate innovative medical devices?].

    Science.gov (United States)

    Martelli, N; van den Brink, H; Denies, F; Dervaux, B; Germe, A F; Prognon, P; Pineau, J

    2014-01-01

    Innovative medical devices offer solutions to medical problems and greatly improve patients' outcomes. Like National Health Technology Assessment (HTA) agencies, hospitals face numerous requests for innovative and costly medical devices. To help local decision-makers, different approaches of hospital-based HTA (HB-HTA) have been adopted worldwide. The objective of the present paper is to explore HB-HTA models for adopting innovative medical devices in France and elsewhere. Four different models have been conceptualized: "ambassador" model, "mini-HTA" model, "HTA unit" model and "internal committee". Apparently, "HTA unit" and "internal committee" (or a mixture of both models) are the prevailing HB-HTA models in France. Nevertheless, some weaknesses of these models have been pointed out in previous works. Only few examples involving hospital pharmacists have been found abroad, except in France and in Italy. Finally, the harmonization of the assessment of innovative medical devices in France needs a better understanding of HB-HTA practices. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. First experiences with the implementation of the European standard EN 62304 on medical device software for the quality assurance of a radiotherapy unit.

    Science.gov (United States)

    Höss, Angelika; Lampe, Christian; Panse, Ralf; Ackermann, Benjamin; Naumann, Jakob; Jäkel, Oliver

    2014-03-21

    According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a

  4. First experiences with the implementation of the European standard EN 62304 on medical device software for the quality assurance of a radiotherapy unit

    International Nuclear Information System (INIS)

    Höss, Angelika; Lampe, Christian; Panse, Ralf; Ackermann, Benjamin; Naumann, Jakob; Jäkel, Oliver

    2014-01-01

    According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a

  5. A systematic review of instruments that assess the implementation of hospital quality management systems.

    NARCIS (Netherlands)

    Groene, O.; Botje, D.; Suñol, R.; Lopez, M.A.; Wagner, C.

    2013-01-01

    Purpose: Health-care providers invest substantial resources to establish and implement hospital quality management systems. Nevertheless, few tools are available to assess implementation efforts and their effect on quality and safety outcomes. This review aims to (i) identify instruments to assess

  6. A Randomized Trial of Pocket-Echocardiography Integrated Mobile Health Device Assessments in Modern Structural Heart Disease Clinics.

    Science.gov (United States)

    Bhavnani, Sanjeev P; Sola, Srikanth; Adams, David; Venkateshvaran, Ashwin; Dash, P K; Sengupta, Partho P

    2018-04-01

    This study sought to determine whether mobile health (mHealth) device assessments used as clinical decision support tools at the point-of-care can reduce the time to treatment and improve long-term outcomes among patients with rheumatic and structural heart diseases (SHD). Newly developed smartphone-connected mHealth devices represent promising methods to diagnose common diseases in resource-limited areas; however, the impact of technology-based care on long-term outcomes has not been rigorously evaluated. A total of 253 patients with SHD were randomized to an initial diagnostic assessment with wireless devices in mHealth clinics (n = 139) or to standard-care (n = 114) in India. mHealth clinics were equipped with point-of-care devices including pocket-echocardiography, smartphone-connected-electrocardiogram blood pressure and oxygen measurements, activity monitoring, and portable brain natriuretic peptide laboratory testing. All individuals underwent comprehensive transthoracic echocardiography to assess the severity of SHD. The primary endpoint was the time to referral for therapy with percutaneous valvuloplasty or surgical valve replacement. Secondary endpoints included the probability of a cardiovascular hospitalization and/or death over 1 year. An initial mHealth assessment was associated with a shorter time to referral for valvuloplasty and/or valve replacement (83 ± 79 days vs. 180 ± 101 days; p Mobile Health Device Assessments in Modern Structural Heart Disease Clinics; NCT02881398). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. A Parallel Implementation of a Smoothed Particle Hydrodynamics Method on Graphics Hardware Using the Compute Unified Device Architecture

    International Nuclear Information System (INIS)

    Wong Unhong; Wong Honcheng; Tang Zesheng

    2010-01-01

    The smoothed particle hydrodynamics (SPH), which is a class of meshfree particle methods (MPMs), has a wide range of applications from micro-scale to macro-scale as well as from discrete systems to continuum systems. Graphics hardware, originally designed for computer graphics, now provide unprecedented computational power for scientific computation. Particle system needs a huge amount of computations in physical simulation. In this paper, an efficient parallel implementation of a SPH method on graphics hardware using the Compute Unified Device Architecture is developed for fluid simulation. Comparing to the corresponding CPU implementation, our experimental results show that the new approach allows significant speedups of fluid simulation through handling huge amount of computations in parallel on graphics hardware.

  8. Radiological hazard assessment of extracorporeal shock wave lithotripsy devices

    International Nuclear Information System (INIS)

    Sprague, D.D.; Vermeere, W.R.

    1987-01-01

    With the recent introduction of ESWL to the clinical environment, a new health physics challenge has entered the medical consulting area. The x-ray imaging systems used in the devices are of a conventional design, but in an unusual configuration that is difficult to properly assess. The scope of this paper considers specific evaluation problems, and deals with methods developed during experience with 4 units in California. Pertinent regulations are also covered, along with a synopsis of data obtained and ALARA recommendations

  9. Nutritional screening, assessment and implementation strategies for adults in an Australian acute tertiary hospital: a best practice implementation report.

    Science.gov (United States)

    Smith, Louise; Chapman, Amanda; Flowers, Kelli; Wright, Kylie; Chen, Tanghua; O'Connor, Charmaine; Astorga, Cecilia; Francis, Nevenka; Vigh, Gia; Wainwright, Craig

    2018-01-01

    The project aimed to improve the effectiveness of nutritional screening and assessment practices through clinical audits and the implementation of evidence-based practice recommendations. In the absence of optimal nutrition, health may decline and potentially manifest as adverse health outcomes. In a hospitalized person, poor nutrition may adversely impact on the person's outcome. If the nutritional status can be ascertained, nutritional needs can be addressed and potential risks minimized.The overall purpose of this project was to review and monitor staff compliance with nutritional screening and assessment best practice recommendations ensuring there is timely, relevant and structured nutritional therapeutic practices that support safe, compassionate and person-centered care in adults in a tertiary hospital in South Western Sydney, Australia, in the acute care setting. A baseline retrospective chart audit was conducted and measured against 10 best practice criteria in relation to nutritional screening and assessment practices. This was followed by a facilitated multidisciplinary focus group to identify targeted strategies, implementation of targeted strategies, and a post strategy implementation chart audit.The project utilized the Joanna Briggs Institute Practical Application of Clinical Evidence System (JBI PACES) and Getting Research into Practice (GRIP) tool, including evidence from other available supporting literature, for promoting change in healthcare practice. The baseline audit revealed deficits between current practice and best practice across the 10 criteria. Barriers for implementation of nutritional screening and assessment best practice criteria were identified by the focus group and an education strategy was implemented. There were improved outcomes across all best practice criteria in the follow-up audit. The baseline audit revealed gaps between current practice and best practice. Through the implementation of a targeted education program and

  10. A systematic review of instruments that assess the implementation of hospital quality management systems.

    Science.gov (United States)

    Groene, Oliver; Botje, Daan; Suñol, Rosa; Lopez, Maria Andrée; Wagner, Cordula

    2013-10-01

    Health-care providers invest substantial resources to establish and implement hospital quality management systems. Nevertheless, few tools are available to assess implementation efforts and their effect on quality and safety outcomes. This review aims to (i) identify instruments to assess the implementation of hospital quality management systems, (ii) describe their measurement properties and (iii) assess the effects of quality management on quality improvement and quality of care outcomes. We performed a systematic literature search from 1990 to 2011 in PubMed, CINAHL, EMBASE, Cochrane Library and Web of Science. In addition, we used snowball strategies, screened the reference lists of eligible papers, reviewed grey literature and contacted experts in the field. and data extraction Two reviewers screened eligible papers based on pre-defined inclusion and exclusion criteria and all authors extracted data. Eligible papers are described in terms of general characteristics (settings, type and level of respondents, mode of data collection), methodological properties (sampling strategy, item derivation, conceptualization of quality management, assessment of reliability and validity, scoring) and application/implementation (accounting for context, organizational adaptations, sensitivity to change, deployment and effect size). Eighteen papers were deemed eligible for inclusion. While some common domains emerged in measurement conceptualization, substantial differences in scope persist. The instruments' measurement properties were insufficiently described and only few instruments assessed links between the implementation of quality management systems (QMS) and improvement strategies or outcomes. There is currently no well-established measure to assess the implementation and effectiveness of quality management systems. Future research should address this gap.

  11. Assessment And Testing of Industrial Devices Robustness Against Cyber Security Attacks

    CERN Document Server

    Tilaro, F

    2011-01-01

    CERN (European Organization for Nuclear Research),like any organization, needs to achieve the conflicting objectives of connecting its operational network to Internet while at the same time keeping its industrial control systems secure from external and internal cyber attacks. With this in mind, the ISA-99[0F1] international cyber security standard has been adopted at CERN as a reference model to define a set of guidelines and security robustness criteria applicable to any network device. Devices robustness represents a key link in the defense-in-depth concept as some attacks will inevitably penetrate security boundaries and thus require further protection measures. When assessing the cyber security robustness of devices we have singled out control system-relevant attack patterns derived from the well-known CAPEC[1F2] classification. Once a vulnerability is identified, it needs to be documented, prioritized and reproduced at will in a dedicated test environment for debugging purposes. CERN - in collaboration ...

  12. Safety assessment in plant layout design using indexing approach: implementing inherent safety perspective. Part 1 - guideword applicability and method description.

    Science.gov (United States)

    Tugnoli, Alessandro; Khan, Faisal; Amyotte, Paul; Cozzani, Valerio

    2008-12-15

    Layout planning plays a key role in the inherent safety performance of process plants since this design feature controls the possibility of accidental chain-events and the magnitude of possible consequences. A lack of suitable methods to promote the effective implementation of inherent safety in layout design calls for the development of new techniques and methods. In the present paper, a safety assessment approach suitable for layout design in the critical early phase is proposed. The concept of inherent safety is implemented within this safety assessment; the approach is based on an integrated assessment of inherent safety guideword applicability within the constraints typically present in layout design. Application of these guidewords is evaluated along with unit hazards and control devices to quantitatively map the safety performance of different layout options. Moreover, the economic aspects related to safety and inherent safety are evaluated by the method. Specific sub-indices are developed within the integrated safety assessment system to analyze and quantify the hazard related to domino effects. The proposed approach is quick in application, auditable and shares a common framework applicable in other phases of the design lifecycle (e.g. process design). The present work is divided in two parts: Part 1 (current paper) presents the application of inherent safety guidelines in layout design and the index method for safety assessment; Part 2 (accompanying paper) describes the domino hazard sub-index and demonstrates the proposed approach with a case study, thus evidencing the introduction of inherent safety features in layout design.

  13. Implementing Strategic Environmental Assessment of spatial planning tools

    International Nuclear Information System (INIS)

    De Montis, Andrea

    2013-01-01

    After more than a decade from the publication of the European Directive 2001/42/CE (Directive) on Strategic Environmental Assessment (SEA), the design and construction of the interested spatial planning instruments has gone through a variety of changes and integrations in European and in world states. This inhomogeneous panorama can be explained with a pattern of institutional structures that have so far affected the implementation of the Directive. The aim of this paper is to investigate the level of implementation of the Directive in Italy by developing a comparative analysis of the quality of integration of SEA within the design of the spatial coordination plan of a set of Italian provinces. Italian practice is analyzed in the framework of a comparative study of worldwide SEA implementation within spatial and land use planning. The results reveal strengths and weaknesses in SEA implementation at the provincial level and, in particular, the emergence of critical areas of research concerning institutional context, public participation, monitoring, and observatory of the spatial transformations. -- Highlights: • This is a comparative analysis of SEA in strategic spatial planning in Italy. • The adhesion of Provinces to the study is remarkable. • SEA implementation and integration into spatial planning is still moderate. • Participation via consultations should be more widespread. • Monitoring and institution of observatories are still in an infancy stage

  14. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  15. Intentional research design in implementation science: implications for the use of nomothetic and idiographic assessment.

    Science.gov (United States)

    Lyon, Aaron R; Connors, Elizabeth; Jensen-Doss, Amanda; Landes, Sara J; Lewis, Cara C; McLeod, Bryce D; Rutt, Christopher; Stanick, Cameo; Weiner, Bryan J

    2017-09-01

    The advancement of implementation science is dependent on identifying assessment strategies that can address implementation and clinical outcome variables in ways that are valid, relevant to stakeholders, and scalable. This paper presents a measurement agenda for implementation science that integrates the previously disparate assessment traditions of idiographic and nomothetic approaches. Although idiographic and nomothetic approaches are both used in implementation science, a review of the literature on this topic suggests that their selection can be indiscriminate, driven by convenience, and not explicitly tied to research study design. As a result, they are not typically combined deliberately or effectively. Thoughtful integration may simultaneously enhance both the rigor and relevance of assessments across multiple levels within health service systems. Background on nomothetic and idiographic assessment is provided as well as their potential to support research in implementation science. Drawing from an existing framework, seven structures (of various sequencing and weighting options) and five functions (Convergence, Complementarity, Expansion, Development, Sampling) for integrating conceptually distinct research methods are articulated as they apply to the deliberate, design-driven integration of nomothetic and idiographic assessment approaches. Specific examples and practical guidance are provided to inform research consistent with this framework. Selection and integration of idiographic and nomothetic assessments for implementation science research designs can be improved. The current paper argues for the deliberate application of a clear framework to improve the rigor and relevance of contemporary assessment strategies.

  16. Methods of assessing functioning of organizational and economic mechanism during innovation process implementation

    Directory of Open Access Journals (Sweden)

    Blinkov Maksim

    2017-01-01

    Full Text Available This paper proposes methods of assessing the efficiency of organizational and economic mechanism of an industrial enterprise when implementing innovation processes. These methods allow continuous monitoring at all stages of innovation process implementation, lead to reduction in costs of innovation activity and enable maximum use of the creative potential of enterprise personnel. The significance and attractiveness of this method is ensured by the fact that it can be applied by industrial companies in any market fields regardless of the lifecycle stage applicable to the studied goods, company and/or innovative process because the composition and the number of specific indicators can be adjusted by the work group both before the study and in the course of the company’s innovative activities (at any stage of their implementation. The multi-sided approach proposed for assessing the efficiency of organizational and economic mechanism of the industrial enterprise when implementing innovation processes ensures full and accurate assessment of the impact of certain factors on the final result.

  17. Assessment of Current Practice for Tank Testing of Small Marine Energy Devices

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    Discussion Report. Equitable Testing and Evaluation of Marine Energy Extraction Devices in terms of Performance, Cost and Environmental Impact. The report is a contribution by Aalborg University (AAU) to the deliverable on Assessment of current practice for tank testing of small marine energy...

  18. Towed Optical Assessment Device (TOAD) Data to Support Benthic Habitat Mapping since 2001

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Optical validation data were collected using a Tethered Optical Assessment Device (TOAD), an underwater sled equipped with an underwater digital video camera and...

  19. Improving risk assessment of color additives in medical device polymers.

    Science.gov (United States)

    Chandrasekar, Vaishnavi; Janes, Dustin W; Forrey, Christopher; Saylor, David M; Bajaj, Akhil; Duncan, Timothy V; Zheng, Jiwen; Riaz Ahmed, Kausar B; Casey, Brendan J

    2018-01-01

    Many polymeric medical device materials contain color additives which could lead to adverse health effects. The potential health risk of color additives may be assessed by comparing the amount of color additive released over time to levels deemed to be safe based on available toxicity data. We propose a conservative model for exposure that requires only the diffusion coefficient of the additive in the polymer matrix, D, to be specified. The model is applied here using a model polymer (poly(ether-block-amide), PEBAX 2533) and color additive (quinizarin blue) system. Sorption experiments performed in an aqueous dispersion of quinizarin blue (QB) into neat PEBAX yielded a diffusivity D = 4.8 × 10 -10 cm 2  s -1 , and solubility S = 0.32 wt %. On the basis of these measurements, we validated the model by comparing predictions to the leaching profile of QB from a PEBAX matrix into physiologically representative media. Toxicity data are not available to estimate a safe level of exposure to QB, as a result, we used a Threshold of Toxicological Concern (TTC) value for QB of 90 µg/adult/day. Because only 30% of the QB is released in the first day of leaching for our film thickness and calculated D, we demonstrate that a device may contain significantly more color additive than the TTC value without giving rise to a toxicological concern. The findings suggest that an initial screening-level risk assessment of color additives and other potentially toxic compounds found in device polymers can be improved. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 310-319, 2018. © 2017 Wiley Periodicals, Inc.

  20. Randomized controlled trial in rural Ethiopia to assess a portable water treatment device.

    Science.gov (United States)

    Boisson, Sophie; Schmidt, Wolf-Peter; Berhanu, Tsegahiwot; Gezahegn, Henock; Clasen, Thomas

    2009-08-01

    We conducted a randomized controlled trial to assess the Lifestraw Personal pipe-style water treatment device among a rural population in Ethiopia. A total of 313 households (including 1516 persons) were randomly assigned either to an intervention group in which each householder received a Lifestraw Personal or a control. Households were visited fortnightly over a five-month intervention period and asked to report any episode of diarrhea during the previous week. A random sample of 160 devices was tested each month to assess the presence of thermotolerant coliforms (TTC) and residual iodine in treated water and to measure flow rate under simulated use. Members of the intervention group had 25% fewer weeks with diarrhea than those of the control group (longitudinal prevalence ratio = 0.75; 95% CI 0.60; 0.95). All 718 filtered water samples were free of TTC, were free of detectable iodine disinfectant, and showed a constant flow rate over time. After the five-month intervention period, 34% of participants reported use of device in the preceding week and 13% reported consistent use. While the device was associated with a 25% reduction in longitudinal prevalence of diarrhea, low levels of use suggest that much of this effect is likely to be attributable to reporting bias that is common in open trials with nonobjective outcomes.

  1. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study

    Directory of Open Access Journals (Sweden)

    Fleming Lora E

    2011-04-01

    Full Text Available Abstract Background Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. Methods In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost of the handheld administration method was recorded and compared to approaches available in the extant literature. Results Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Conclusions Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data

  2. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J

    2011-04-01

    Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the

  3. Constructing the informatics and information technology foundations of a medical device evaluation system: a report from the FDA unique device identifier demonstration.

    Science.gov (United States)

    Drozda, Joseph P; Roach, James; Forsyth, Thomas; Helmering, Paul; Dummitt, Benjamin; Tcheng, James E

    2018-02-01

    The US Food and Drug Administration (FDA) has recognized the need to improve the tracking of medical device safety and performance, with implementation of Unique Device Identifiers (UDIs) in electronic health information as a key strategy. The FDA funded a demonstration by Mercy Health wherein prototype UDIs were incorporated into its electronic information systems. This report describes the demonstration's informatics architecture. Prototype UDIs for coronary stents were created and implemented across a series of information systems, resulting in UDI-associated data flow from manufacture through point of use to long-term follow-up, with barcode scanning linking clinical data with UDI-associated device attributes. A reference database containing device attributes and the UDI Research and Surveillance Database (UDIR) containing the linked clinical and device information were created, enabling longitudinal assessment of device performance. The demonstration included many stakeholders: multiple Mercy departments, manufacturers, health system partners, the FDA, professional societies, the National Cardiovascular Data Registry, and information system vendors. The resulting system of systems is described in detail, including entities, functions, linkage between the UDIR and proprietary systems using UDIs as the index key, data flow, roles and responsibilities of actors, and the UDIR data model. The demonstration provided proof of concept that UDIs can be incorporated into provider and enterprise electronic information systems and used as the index key to combine device and clinical data in a database useful for device evaluation. Keys to success and challenges to achieving this goal were identified. Fundamental informatics principles were central to accomplishing the system of systems model. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  4. Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals

    DEFF Research Database (Denmark)

    Lorentzen, Jakob; Grey, Michael J; Geertsen, Svend Sparre

    2012-01-01

    was measured with the portable device and a stationary torque motor. Inter- and intra-rater reliability was assessed with the intra-class correlation coefficient (ICC). RESULTS: Stiffness measures with the portable and stationary devices were significantly correlated for controls and MS participants (p...

  5. Manufacturer Usage Description Specification Implementation

    OpenAIRE

    Srinivasan, Kaushik

    2017-01-01

    Manufacturer Usage Description Specification (MUDS) is aframework under RFC development that aims to automate Internet access control rules for IoT devices . These access controls prevent malicious IoT devices from attacking other devices and also protect the IoT devices from being attacked by other devices.We are implementing this framework and trying to improve its security.

  6. Lightweight cryptography for constrained devices

    DEFF Research Database (Denmark)

    Alippi, Cesare; Bogdanov, Andrey; Regazzoni, Francesco

    2014-01-01

    Lightweight cryptography is a rapidly evolving research field that responds to the request for security in resource constrained devices. This need arises from crucial pervasive IT applications, such as those based on RFID tags where cost and energy constraints drastically limit the solution...... complexity, with the consequence that traditional cryptography solutions become too costly to be implemented. In this paper, we survey design strategies and techniques suitable for implementing security primitives in constrained devices....

  7. Residual Isocyanates in Medical Devices and Products: A Qualitative and Quantitative Assessment

    Directory of Open Access Journals (Sweden)

    Gillian Franklin

    2016-01-01

    Full Text Available We conducted a pilot qualitative and quantitative assessment of residual isocyanates and their potential initial exposures in neonates, as little is known about their contact effect. After a neonatal intensive care unit (NICU stockroom inventory, polyurethane (PU and PU foam (PUF devices and products were qualitatively evaluated for residual isocyanates using Surface SWYPE ™ . Those containing isocyanates were quantitatively tested for methylene diphenyl diisocyanate (MDI species, using UPLC-UV-MS/MS method. Ten of 37 products and devices tested, indicated both free and bound residual surface isocyanates; PU/PUF pieces contained aromatic isocyanates; one product contained aliphatic isocyanates. Overall, quantified mean MDI concentrations were low (4,4‘-MDI = 0.52 to 140.1 pg/mg and (2,4‘-MDI = 0.01 to 4.48 pg/mg. The 4,4‘-MDI species had the highest measured concentration (280 pg/mg. Commonly used medical devices/products contain low, but measurable concentrations of residual isocyanates. Quantifying other isocyanate species and neonatal skin exposure to isocyanates from these devices and products requires further investigation.

  8. Hardware implementation of adaptive filtering using charge-coupled devices. [For perimeter security sensors

    Energy Technology Data Exchange (ETDEWEB)

    Donohoe, G.W.

    1977-01-01

    Sandia Laboratories' Digital Systems Division/1734, as part of its work on the Base and Installation Security Systems (BISS) program has been making use of adaptive digital filters to improve the signal-to-noise ratio of perimeter sensor signals. In particular, the Widrow-Hoff least-mean-squares algorithm has been used extensively. This non-recursive linear predictor has been successful in extracting aperiodic signals from periodic noise. The adaptive filter generates a predictor signal which is subtracted from the input signal to produce an error signal. The value of this error is fed back to the filter to improve the quality of the next prediction. Implementation of the Widrow adaptive filter using a Charge-Coupled Device tapped analog delay line, analog voltage multipliers and operational amplifiers is described. The resulting filter adapts to signals with frequency components as high as several megahertz.

  9. The implementation of skill assessment by the educators on the mathematics learning process in senior high school

    Science.gov (United States)

    Lestariani, I.; Sujadi, I.; Pramudya, I.

    2018-03-01

    The purpose of research to describe and know the implementation of skill assessment on the mathematics learning process with the high school mathematics teacher as the subject because it is less fully implemented. This research is the type of the descriptive qualitative method. The data was collecting observation method, interview and documentation. The result showed that on the planning stage of the implementation of skill assessment, there were many teachers who had not prepared all the completeness with various assessment techniques through performance, project and portfolio. The teacher was prepared the list of questions. On the implementation stage, there were many teachers who had not understand the stage of completing the assessment with the appropriate instrument method and development. On the reporting stage, discovered that teachers faced the difficulty on preparing scoring report with the range value. Aside from that, the teachers had not prepared the assessment instrument very well on the planning stage. It can be concluded that the implementation of skill assessment has been implemented but not maximally because educators don’t understand about the skill assessment and the number of instrument that must be prepared before the assessment.

  10. Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels.

    Science.gov (United States)

    Tapia-Siles, Silvia C; Coleman, Stuart; Cuschieri, Alfred

    2016-02-01

    Previous reports have described several candidates, which have the potential to replace colonoscopy, but to date, there is still no device capable of fully replacing flexible colonoscopy in the management of colonic disorders and for mass adult population screening for asymptomatic colorectal cancer. NASA developed the TRL methodology to describe and define the stages of development before use and marketing of any device. The definitions of the TRLS used in the present review are those formulated by "The US Department of Defense Technology Readiness Assessment Guidance" but adapted to micro-robots for colonoscopy. All the devices included are reported in scientific literature. They were identified by a systematic search in Web of Science, PubMed and IEEE Xplore amongst other sources. Devices that clearly lack the potential for full replacement of flexible colonoscopy were excluded. The technological salient features of all the devices included for assessment are described briefly, with particular focus on device propulsion. The devices are classified according to the TRL criteria based on the reported information. An analysis is next undertaken of the characteristics and salient features of the devices included in the review: wireless/tethered devices, data storage-transmission and navigation, additional functionality, residual technology challenges and clinical and socio-economical needs. Few devices currently possess the required functionality and performance to replace the conventional colonoscopy. The requirements, including functionalities which favour the development of a micro-robot platform to replace colonoscopy, are highlighted.

  11. An introduction to direct access storage devices

    CERN Document Server

    Sierra, Hugh M

    2012-01-01

    This book presents an exposition of the technology, design, organization, and structure of direct access storage devices (disk drives). It includes a discussion of the evolution of the technology (magnetic recording) and an assessment of other storage technologies, including optical recording. Examples of codes used in past implementations of disk drives as well as an application of disk drive usage dictated by reliability considerations are also included. The presentation assumes a minimum knowledge of magnetic recording, servomechanism design, and coding.

  12. Assessment of the Implementation of the Secondary School Skill ...

    African Journals Online (AJOL)

    This study was conducted to assess how the Nigerian secondary school vocational and technical education curriculum was implemented with a view to ascertain the extent to which it has empowered students for self-employment. The descriptive survey research design was adopted for the study. The sample comprised 380 ...

  13. Assessing subacute mild traumatic brain injury with a portable virtual reality balance device.

    Science.gov (United States)

    Wright, W Geoffrey; McDevitt, Jane; Tierney, Ryan; Haran, F Jay; Appiah-Kubi, Kwadwo Osei; Dumont, Alex

    2017-07-01

    Balance impairment is a common sensorimotor symptom in mild traumatic brain injury (mTBI). We designed an affordable, portable virtual reality (VR)-based balance screening device (Virtual Environment TBI Screen [VETS]), which will be validated relative to the Neurocom Sensory Organization Test (SOT) to determine if it can replace commonly used postural assessments. This preliminary study examines healthy adults (n = 56) and adults with mTBI (n = 11). Participants performed six upright postural tasks on the VETS and the SOT. Analysis of variance was used to determine between-group differences. Pearson's correlations were used to establish construct validity. Known-groups approach was used to establish classification accuracy. The mTBI cohort performed significantly worse than the healthy cohort on the new device (p = 0.001). The new device has 91.0% accuracy and an ROC curve with a significant area-under-the-curve (AUC = 0.865, p virtual reality can be economically integrated into the clinical setting for easy testing of postural control in neurologically impaired populations. Tailoring postural assessments to include tasks that rely on visual and vestibular integration will increase the accuracy of detecting balance impairment following mild traumatic brain injury.

  14. Bangladesh Model/Survey Note : Assessment of Implementation of Public Procurement Regulations

    OpenAIRE

    World Bank

    2009-01-01

    The report provides an assessment of the status of implementation of public procurement regulations 2003. The objective was to assess the performance of the system using a two-way approach. The report summarizes the major findings of the assessment carried out through a Bank-Government joint collaboration survey with sample data of two financial years (FY2006 and FY2007) from the key secto...

  15. Implementation of health impact assessment in Danish municipal context.

    Science.gov (United States)

    Kraemer, Stella Rebecca Johnsdatter; Nikolajsen, Louise Theilgaard; Gulis, Gabriel

    2014-12-01

    Implementation of Health Impact Assessment (HIA) in Danish municipalities has been analyzed using the Roger's Diffusion of Innovation Theory. Municipalities were chosen from among those who presented their health policies on websites according to the status of inclusion of HIA into health policy. Qualitative interviews were conducted in 6 municipalities (3 with HIA inducted in their health policy and 3 without it) gathering information on knowledge and attitudes to HIA, barriers to its implementation, social system and communication channels used or expected to be used for implementation of HIA. No significant differences were found among analyzed municipalities by status of HIA inclusion into health policy. Among barriers; a lack of tools with general validity, a lack of intersectoral working culture, balance between centralized versus participatory way of working and organizational structure of a municipality, and a lack of capacities were enlisted as most relevant. The last one is a crucial factor of an internal social system of a municipality. With regards to communication channels, reporting and presentation skills of implementers and doers are of key importance. Systematic and sustainable capacity building is needed to achieve high level implementation of HIA in Danish municipalities. Development of validated tools, most importantly screening tools with focus on priorities of national public health policy would enhance implementation on municipal level.

  16. Implementation of an ergonomics intervention in a Swedish flight baggage handling company-A process evaluation.

    Science.gov (United States)

    Bergsten, Eva L; Mathiassen, Svend Erik; Larsson, Johan; Kwak, Lydia

    2018-01-01

    To conduct a process evaluation of the implementation of an ergonomics training program aimed at increasing the use of loading assist devices in flight baggage handling. Feasibility related to the process items recruitment, reach, context, dose delivered (training time and content); dose received (participants' engagement); satisfaction with training; intermediate outcomes (skills, confidence and behaviors); and barriers and facilitators of the training intervention were assessed by qualitative and quantitative methods. Implementation proved successful regarding dose delivered, dose received and satisfaction. Confidence among participants in the training program in using and talking about devices, observed use of devices among colleagues, and internal feedback on work behavior increased significantly (pjob insecurity. In identifying important barriers and facilitators for a successful outcome, this study can help supporting the effectiveness of future interventions. Our results suggest that barriers caused by organizational changes may likely be alleviated by recruiting motivated trainees and securing strong organizational support for the implementation.

  17. A modified theoretical framework to assess implementation fidelity of adaptive public health interventions.

    Science.gov (United States)

    Pérez, Dennis; Van der Stuyft, Patrick; Zabala, Maríadel Carmen; Castro, Marta; Lefèvre, Pierre

    2016-07-08

    One of the major debates in implementation research turns around fidelity and adaptation. Fidelity is the degree to which an intervention is implemented as intended by its developers. It is meant to ensure that the intervention maintains its intended effects. Adaptation is the process of implementers or users bringing changes to the original design of an intervention. Depending on the nature of the modifications brought, adaptation could either be potentially positive or could carry the risk of threatening the theoretical basis of the intervention, resulting in a negative effect on expected outcomes. Adaptive interventions are those for which adaptation is allowed or even encouraged. Classical fidelity dimensions and conceptual frameworks do not address the issue of how to adapt an intervention while still maintaining its effectiveness. We support the idea that fidelity and adaptation co-exist and that adaptations can impact either positively or negatively on the intervention's effectiveness. For adaptive interventions, research should answer the question how an adequate fidelity-adaptation balance can be reached. One way to address this issue is by looking systematically at the aspects of an intervention that are being adapted. We conducted fidelity research on the implementation of an empowerment strategy for dengue prevention in Cuba. In view of the adaptive nature of the strategy, we anticipated that the classical fidelity dimensions would be of limited use for assessing adaptations. The typology we used in the assessment-implemented, not-implemented, modified, or added components of the strategy-also had limitations. It did not allow us to answer the question which of the modifications introduced in the strategy contributed to or distracted from outcomes. We confronted our empirical research with existing literature on fidelity, and as a result, considered that the framework for implementation fidelity proposed by Carroll et al. in 2007 could potentially meet

  18. Design and implementation of a risk assessment module in a spatial decision support system

    Science.gov (United States)

    Zhang, Kaixi; van Westen, Cees; Bakker, Wim

    2014-05-01

    The spatial decision support system named 'Changes SDSS' is currently under development. The goal of this system is to analyze changing hydro-meteorological hazards and the effect of risk reduction alternatives to support decision makers in choosing the best alternatives. The risk assessment module within the system is to assess the current risk, analyze the risk after implementations of risk reduction alternatives, and analyze the risk in different future years when considering scenarios such as climate change, land use change and population growth. The objective of this work is to present the detailed design and implementation plan of the risk assessment module. The main challenges faced consist of how to shift the risk assessment from traditional desktop software to an open source web-based platform, the availability of input data and the inclusion of uncertainties in the risk analysis. The risk assessment module is developed using Ext JS library for the implementation of user interface on the client side, using Python for scripting, as well as PostGIS spatial functions for complex computations on the server side. The comprehensive consideration of the underlying uncertainties in input data can lead to a better quantification of risk assessment and a more reliable Changes SDSS, since the outputs of risk assessment module are the basis for decision making module within the system. The implementation of this module will contribute to the development of open source web-based modules for multi-hazard risk assessment in the future. This work is part of the "CHANGES SDSS" project, funded by the European Community's 7th Framework Program.

  19. Challenges in the Assessment of Medical Devices: The MedtecHTA Project.

    Science.gov (United States)

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    Assessing medical devices (MDs) raises challenges which require us to reflect on whether current methods are adequate. Major features of devices are: (i) device-operator interaction can generate learning curve effects; (ii) incremental nature of innovation needs to be addressed by careful identification of the alternatives for comparative and incremental cost-effectiveness analysis; and (iii) broader organizational impact in terms of training and infrastructure, coupled with dynamic pricing, requires a more flexible approach to costing. The objective of the MedtecHTA project was to investigate improvements in HTA methods to allow for more comprehensive evaluation of MDs. It consisted of several work packages concerning (i) the available evidence on the currently adopted approaches for regulation and HTA of medical devices; (ii) the geographical variation in access to MDs; (iii) the development of methodological frameworks for conducting comparative effectiveness research and economic evaluation of MDs; and (iv) the organizational impact of MDs. This introductory paper summarizes the main results of the project and draws out the main overarching themes. This supplement represents a comprehensive report of all the main findings of the MedtecHTA project, and it is intended to be the main source for researchers and policy makers wanting information on the project. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics Published by John Wiley & Sons, Ltd.

  20. Design, Development and Implementation of a Smartphone Overdependence Management System for the Self-Control of Smart Devices

    Directory of Open Access Journals (Sweden)

    Seo-Joon Lee

    2016-12-01

    Full Text Available Background: Smartphone overdependence is a type of mental disorder that requires continuous treatment for cure and prevention. A smartphone overdependence management system that is based on scientific evidence is required. This study proposes the design, development and implementation of a smartphone overdependence management system for self-control of smart devices. Methods: The system architecture of the Smartphone Overdependence Management System (SOMS primarily consists of four sessions of mental monitoring: (1 Baseline settlement session; (2 Assessment session; (3 Sensing & monitoring session; and (4 Analysis and feedback session. We developed the smartphone-usage-monitoring application (app and MindsCare personal computer (PC app to receive and integrate usage data from smartphone users. We analyzed smartphone usage data using the Chi-square Automatic Interaction Detector (CHAID. Based on the baseline settlement results, we designed a feedback service to intervene. We implemented the system using 96 participants for testing and validation. The participants were classified into two groups: the smartphone usage control group (SUC and the smartphone usage disorder addiction group (SUD. Results: The background smartphone monitoring app of the proposed system successfully monitored the smartphone usage based on the developed algorithm. The usage minutes of the SUD were higher than the usage minutes of the SUC in 11 of the 16 categories developed in our study. Via the MindsCare PC app, the data were successfully integrated and stored, and managers can successfully analyze and diagnose based on the monitored data. Conclusion: The SOMS is a new system that is based on integrated personalized data for evidence-based smartphone overdependence intervention. The SOMS is useful for managing usage data, diagnosing smartphone overdependence, classifying usage patterns and predicting smartphone overdependence. This system contributes to the diagnosis of

  1. Architecture, development and implementation of a SWIR to visible integrated up-conversion imaging device

    Science.gov (United States)

    Sarusi, Gabby; Templeman, Tzvi; Hechster, Elad; Nissim, Nimrod; Vitenberg, Vladimir; Maman, Nitzan; Tal, Amir; Solodar, Assi; Makov, Guy; Abdulhalim, Ibrahim; Visoly-Fisher, Iris; Golan, Yuval

    2016-04-01

    A new concept of short wavelength infrared (SWIR) to visible upconversion integrated imaging device is proposed, modeled and some initial measured results are presented. The device is a hybrid inorganic-organic device that comprises six nano-metric scale sub-layers grown on n-type GaAs substrates. The first layer is a ~300nm thick PbSe nano-columnar absorber layer grown in (111) orientation to the substrate plan (100), with a diameter of 8- 10nm and therefore exhibit quantum confinement effects parallel to the substrate and bulk properties perpendicular to it. The advantage of this structure is the high oscillator strength and hence absorption to incoming SWIR photons while maintaining the high bulk mobility of photo-excited charges along the columns. The top of the PbSe absorber layer is coated with 20nm thick metal layer that serves as a dual sided mirror, as well as a potentially surface plasmon enhanced absorption in the PbSe nano-columns layer. The photo-excited charges (holes and electrons in opposite directions) are drifted under an external applied field to the OLED section (that is composed of a hole transport layer, an emission layer and an electron transport layer) where they recombine with injected electron from the transparent cathode and emit visible light through this cathode. Due to the high absorption and enhanced transport properties this architecture has the potential of high quantum efficiency, low cost and easy implementation in any optical system. As a bench-mark, alternative concept where InGaAs/InP heterojunction couple to liquid crystal optical spatial light modulator (OSLM) structure was built that shows a full upconversion to visible of 1550nm laser light.

  2. Remaining useful life assessment of lithium-ion batteries in implantable medical devices

    Science.gov (United States)

    Hu, Chao; Ye, Hui; Jain, Gaurav; Schmidt, Craig

    2018-01-01

    This paper presents a prognostic study on lithium-ion batteries in implantable medical devices, in which a hybrid data-driven/model-based method is employed for remaining useful life assessment. The method is developed on and evaluated against data from two sets of lithium-ion prismatic cells used in implantable applications exhibiting distinct fade performance: 1) eight cells from Medtronic, PLC whose rates of capacity fade appear to be stable and gradually decrease over a 10-year test duration; and 2) eight cells from Manufacturer X whose rates appear to be greater and show sharp increase after some period over a 1.8-year test duration. The hybrid method enables online prediction of remaining useful life for predictive maintenance/control. It consists of two modules: 1) a sparse Bayesian learning module (data-driven) for inferring capacity from charge-related features; and 2) a recursive Bayesian filtering module (model-based) for updating empirical capacity fade models and predicting remaining useful life. A generic particle filter is adopted to implement recursive Bayesian filtering for the cells from the first set, whose capacity fade behavior can be represented by a single fade model; a multiple model particle filter with fixed-lag smoothing is proposed for the cells from the second data set, whose capacity fade behavior switches between multiple fade models.

  3. Design and Simulation of MEMS Devices using Interval Analysis

    International Nuclear Information System (INIS)

    Shanmugavalli, M; Uma, G; Vasuki, B; Umapathy, M

    2006-01-01

    Modeling and simulation of MEMS devices are used to optimize the design, to improve the performance of the device, to reduce time to market, to minimize development time and cost by avoiding unnecessary design cycles and foundry runs. The major design objectives in any device design, is to meet the required functional parameters and the reliability of the device. The functional parameters depend on the geometry of the structure, material properties and process parameters. All model parameters act as input to optimize the functional parameters. The major difficulty the designer faces is the dimensions and properties used in the simulation of the MEMS devices can not be exactly followed during fabrication. In order to overcome this problem, the designer must test the device in simulation for bound of parameters involved in it. The paper demonstrates the use of interval methods to assess the electromechanical behaviour of micro electromechanical systems (MEMS) under the presence of manufacturing and process uncertainties. Interval method guides the design of pullin voltage analysis of fixed-fixed beam to achieve a robust and reliable design in a most efficient way. The methods are implemented numerically using Coventorware and analytically using Intlab

  4. Designing Conservation Corridors in Production Landscapes: Assessment Methods, Implementation Issues, and Lessons Learned

    Directory of Open Access Journals (Sweden)

    Amanda T. Lombard

    2010-09-01

    Full Text Available Designing broad-scale conservation corridors has become increasingly common as a way of conducting an assessment for achieving targets for the representation and persistence of nature. However, since many of these corridors must traverse agricultural and other production landscapes, planning and implementation are not trivial tasks. Most approaches to conservation assessments in the dynamic world of production landscapes are data-intensive and analytically complex. However, in the real world, donor and other external requirements impose time and budget constraints, and dictate strong stakeholder involvement in the entire planning process. In order to accommodate this, assessments must be rapid, cheap, and the approach and products must be comprehensible and acceptable to stakeholders. Here we describe such an assessment aimed at identifying and implementing a network of conservation corridors in the Gouritz Initiative project domain of South Africa's Cape Floristic Region hotspot. We used empirical data and expert knowledge to identify a corridor network hypothesized to sustain key ecological and evolutionary processes. We also consulted experts to provide a spatially explicit assessment of the opportunity costs of conservation associated with agriculture, the predominant land use in the region. We used these products to identify categories of land requiring different actions and instruments to achieve conservation goals, thereby moving from the "where" to the "how" of conservation. This information was then fed into the collaborative strategy development process for the Gouritz Initiative. Our discussion emphasizes the lessons that we learnt from undertaking this assessment, particularly lessons regarding the implementation of the planning products. We conclude that at the outset of any planning project, a consensus on the vision must be achieved, a detailed social assessment of appropriate institutions must be undertaken, and a learning

  5. Optimal Pain Assessment in Pediatric Rehabilitation: Implementation of a Nursing Guideline.

    Science.gov (United States)

    Kingsnorth, Shauna; Joachimides, Nick; Krog, Kim; Davies, Barbara; Higuchi, Kathryn Smith

    2015-12-01

    In Ontario, Canada, the Registered Nurses' Association promotes a Best Practice Spotlight Organization initiative to enhance evidence-based practice. Qualifying organizations are required to implement strategies, evaluate outcomes, and sustain practices aligned with nursing clinical practice guidelines. This study reports on the development and evaluation of a multifaceted implementation strategy to support adoption of a nursing clinical practice guideline on the assessment and management of acute pain in a pediatric rehabilitation and complex continuing care hospital. Multiple approaches were employed to influence behavior, attitudes, and awareness around optimal pain practice (e.g., instructional resources, electronic reminders, audits, and feedback). Four measures were introduced to assess pain in communicating and noncommunicating children as part of a campaign to treat pain as the fifth vital sign. A prospective repeated measures design examined survey and audit data to assess practice aligned with the guideline. The Knowledge and Attitudes Survey (KNAS) was adapted to ensure relevance to the local practice setting and was assessed before and after nurses' participation in three education modules. Audit data included client demographics and pain scores assessed annually over a 3-year window. A final sample of 69 nurses (78% response rate) provided pre-/post-survey data. A total of 108 pediatric surgical clients (younger than 19 years) contributed audit data across the three collection cycles. Significant improvements in nurses' knowledge, attitudes, and behaviors related to optimal pain care for children with disabilities were noted following adoption of the pain clinical practice guideline. Targeted guideline implementation strategies are central to supporting optimal pain practice. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  6. Poster: Virtual reality interaction using mobile devices

    KAUST Repository

    Aseeri, Sahar A.

    2013-03-01

    In this work we aim to implement and evaluate alternative approaches for interacting with virtual environments on mobile devices for navigation, object selection and manipulation. Interaction with objects in virtual worlds using traditional input such as current state-of-the-art devices is often difficult and could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. We have developed new methods to perform different kinds of interactions using a mobile device (e.g. a smartphone) both as input device, performing selection and manipulation of objects, and as output device, utilizing the screen as an extra view (virtual camera or information display). Our hypothesis is that interaction via mobile devices facilitates simple tasks like the ones described within immersive virtual reality systems. We present here our initial implementation and result. © 2013 IEEE.

  7. Network Coding Applications and Implementations on Mobile Devices

    DEFF Research Database (Denmark)

    Fitzek, Frank; Pedersen, Morten Videbæk; Heide, Janus

    2010-01-01

    Network coding has attracted a lot of attention lately. The goal of this paper is to demonstrate that the implementation of network coding is feasible on mobile platforms. The paper will guide the reader through some examples and demonstrate uses for network coding. Furthermore the paper will also...... show that the implementation of network coding is feasible today on commercial mobile platforms....

  8. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  9. Commitment to Change and Challenges to Implementing Changes After Workplace-Based Assessment Rater Training.

    Science.gov (United States)

    Kogan, Jennifer R; Conforti, Lisa N; Yamazaki, Kenji; Iobst, William; Holmboe, Eric S

    2017-03-01

    Faculty development for clinical faculty who assess trainees is necessary to improve assessment quality and impor tant for competency-based education. Little is known about what faculty plan to do differently after training. This study explored the changes faculty intended to make after workplace-based assessment rater training, their ability to implement change, predictors of change, and barriers encountered. In 2012, 45 outpatient internal medicine faculty preceptors (who supervised residents) from 26 institutions participated in rater training. They completed a commitment to change form listing up to five commitments and ranked (on a 1-5 scale) their motivation for and anticipated difficulty implementing each change. Three months later, participants were interviewed about their ability to implement change and barriers encountered. The authors used logistic regression to examine predictors of change. Of 191 total commitments, the most common commitments focused on what faculty would change about their own teaching (57%) and increasing direct observation (31%). Of the 183 commitments for which follow-up data were available, 39% were fully implemented, 40% were partially implemented, and 20% were not implemented. Lack of time/competing priorities was the most commonly cited barrier. Higher initial motivation (odds ratio [OR] 2.02; 95% confidence interval [CI] 1.14, 3.57) predicted change. As anticipated difficulty increased, implementation became less likely (OR 0.67; 95% CI 0.49, 0.93). While higher baseline motivation predicted change, multiple system-level barriers undermined ability to implement change. Rater-training faculty development programs should address how faculty motivation and organizational barriers interact and influence ability to change.

  10. Computational design of RNA parts, devices, and transcripts with kinetic folding algorithms implemented on multiprocessor clusters.

    Science.gov (United States)

    Thimmaiah, Tim; Voje, William E; Carothers, James M

    2015-01-01

    With progress toward inexpensive, large-scale DNA assembly, the demand for simulation tools that allow the rapid construction of synthetic biological devices with predictable behaviors continues to increase. By combining engineered transcript components, such as ribosome binding sites, transcriptional terminators, ligand-binding aptamers, catalytic ribozymes, and aptamer-controlled ribozymes (aptazymes), gene expression in bacteria can be fine-tuned, with many corollaries and applications in yeast and mammalian cells. The successful design of genetic constructs that implement these kinds of RNA-based control mechanisms requires modeling and analyzing kinetically determined co-transcriptional folding pathways. Transcript design methods using stochastic kinetic folding simulations to search spacer sequence libraries for motifs enabling the assembly of RNA component parts into static ribozyme- and dynamic aptazyme-regulated expression devices with quantitatively predictable functions (rREDs and aREDs, respectively) have been described (Carothers et al., Science 334:1716-1719, 2011). Here, we provide a detailed practical procedure for computational transcript design by illustrating a high throughput, multiprocessor approach for evaluating spacer sequences and generating functional rREDs. This chapter is written as a tutorial, complete with pseudo-code and step-by-step instructions for setting up a computational cluster with an Amazon, Inc. web server and performing the large numbers of kinefold-based stochastic kinetic co-transcriptional folding simulations needed to design functional rREDs and aREDs. The method described here should be broadly applicable for designing and analyzing a variety of synthetic RNA parts, devices and transcripts.

  11. Supporting Multiple Pointing Devices in Microsoft Windows

    DEFF Research Database (Denmark)

    Westergaard, Michael

    2002-01-01

    In this paper the implementation of a Microsoft Windows driver including APIs supporting multiple pointing devices is presented. Microsoft Windows does not natively support multiple pointing devices controlling independent cursors, and a number of solutions to this have been implemented by us and...... and others. Here we motivate and describe a general solution, and how user applications can use it by means of a framework. The device driver and the supporting APIs will be made available free of charge. Interested parties can contact the author for more information....

  12. Designing Security-Hardened Microkernels For Field Devices

    Science.gov (United States)

    Hieb, Jeffrey; Graham, James

    Distributed control systems (DCSs) play an essential role in the operation of critical infrastructures. Perimeter field devices are important DCS components that measure physical process parameters and perform control actions. Modern field devices are vulnerable to cyber attacks due to their increased adoption of commodity technologies and that fact that control networks are no longer isolated. This paper describes an approach for creating security-hardened field devices using operating system microkernels that isolate vital field device operations from untrusted network-accessible applications. The approach, which is influenced by the MILS and Nizza architectures, is implemented in a prototype field device. Whereas, previous microkernel-based implementations have been plagued by poor inter-process communication (IPC) performance, the prototype exhibits an average IPC overhead for protected device calls of 64.59 μs. The overall performance of field devices is influenced by several factors; nevertheless, the observed IPC overhead is low enough to encourage the continued development of the prototype.

  13. Design of a factorial experiment with randomization restrictions to assess medical device performance on vascular tissue.

    Science.gov (United States)

    Diestelkamp, Wiebke S; Krane, Carissa M; Pinnell, Margaret F

    2011-05-20

    Energy-based surgical scalpels are designed to efficiently transect and seal blood vessels using thermal energy to promote protein denaturation and coagulation. Assessment and design improvement of ultrasonic scalpel performance relies on both in vivo and ex vivo testing. The objective of this work was to design and implement a robust, experimental test matrix with randomization restrictions and predictive statistical power, which allowed for identification of those experimental variables that may affect the quality of the seal obtained ex vivo. The design of the experiment included three factors: temperature (two levels); the type of solution used to perfuse the artery during transection (three types); and artery type (two types) resulting in a total of twelve possible treatment combinations. Burst pressures of porcine carotid and renal arteries sealed ex vivo were assigned as the response variable. The experimental test matrix was designed and carried out as a split-plot experiment in order to assess the contributions of several variables and their interactions while accounting for randomization restrictions present in the experimental setup. The statistical software package SAS was utilized and PROC MIXED was used to account for the randomization restrictions in the split-plot design. The combination of temperature, solution, and vessel type had a statistically significant impact on seal quality. The design and implementation of a split-plot experimental test-matrix provided a mechanism for addressing the existing technical randomization restrictions of ex vivo ultrasonic scalpel performance testing, while preserving the ability to examine the potential effects of independent factors or variables. This method for generating the experimental design and the statistical analyses of the resulting data are adaptable to a wide variety of experimental problems involving large-scale tissue-based studies of medical or experimental device efficacy and performance.

  14. Increasing the Frequency and Timeliness of Pain Assessment and Management in Long-Term Care: Knowledge Transfer and Sustained Implementation

    Directory of Open Access Journals (Sweden)

    Thomas Hadjistavropoulos

    2016-01-01

    Full Text Available Background. Although feasible protocols for pain assessment and management in long-term care (LTC have been developed, these have not been implemented on a large-scale basis. Objective. To implement a program of regular pain assessment in two LTC facilities, using implementation science principles, and to evaluate the process and success of doing so. Methods. The implementation protocol included a pain assessment workshop and the establishment of a nurse Pain Champion. Quality indicators were tracked before and after implementation. Focus groups and interviews with staff were also conducted. Results. The implementation effort was successful in increasing and regularizing pain assessments. This was sustained during the follow-up period. Staff members reported enthusiasm about the protocol at baseline and positive results following its implementation. Despite the success in increasing assessments, we did not identify changes in the percentages of patients reported as having moderate-to-severe pain. Discussion. It is our hope that our feasibility demonstration will encourage more facilities to improve their pain assessment/management practices. Conclusions. It is feasible to implement regular and systematic pain assessment in LTC. Future research should focus on ensuring effective clinical practices in response to assessment results, and determination of longer-term sustainability.

  15. Implementing DOE guidance for hazards assessments at Rocky Flats Plant

    International Nuclear Information System (INIS)

    Zimmerman, G.A.

    1993-01-01

    Hazards Assessments are performed for a variety of activities and facilities at Rocky Flats Plant. Prior to 1991, there was no guidance for performing Hazards Assessments. Each organization that performed Hazards Assessments used its own methodology with no attempt at standardization. In 1991, DOE published guidelines for the performance of Hazards Assessments for Emergency Planning (DOE-EPG-5500.1, ''Guidance for a Hazards Assessment Methodology''). Subsequently, in 1992, DOE published a standard for the performance of Hazards Assessments (DOE-STD-1027-92, ''Hazard Categorization and Accident Analysis, Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports''). Although these documents are a step in the direction of standardization, there remains a great deal of interpretation and subjective implementation in the performance of Hazards Assessments. Rocky Flats Plant has initiated efforts to develop a uniform and standard process to be used for Hazards Assessments

  16. An architecture for device independent interfacing

    International Nuclear Information System (INIS)

    Pace, D.M.

    1990-01-01

    Achieving device independence for software applications is required for all but a small number of critical real time applications. Device independence is achieved by establishing protocols and building protocol interpreters for the specific devices. Data structures containing pointers to functions provide a flexible architecture for implementing protocol translation. 3 refs., 5 figs

  17. Comparison of the methods for determination of calibration and verification intervals of measuring devices

    Directory of Open Access Journals (Sweden)

    Toteva Pavlina

    2017-01-01

    Full Text Available The paper presents different determination and optimisation methods for verification intervals of technical devices for monitoring and measurement based on the requirements of some widely used international standards, e.g. ISO 9001, ISO/IEC 17020, ISO/IEC 17025 etc., maintained by various organizations implementing measuring devices in practice. Comparative analysis of the reviewed methods is conducted in terms of opportunities for assessing the adequacy of interval(s for calibration of measuring devices and their optimisation accepted by an organization – an extension or reduction depending on the obtained results. The advantages and disadvantages of the reviewed methods are discussed, and recommendations for their applicability are provided.

  18. Implementation of the natural resource damage assessment rule

    International Nuclear Information System (INIS)

    1991-11-01

    Regulations have been promulgated by the Department of Interior (DOI) which provide an administrative process whereby natural resource trustees may establish the type and extent of injury and evaluate the damages to natural resources. These regulations provide an optional mechanism for Natural Resource Damage Assessments (NRDAs), with four major components. A workshop was held to develop recommendations for DOE-OR regarding implementation of the DOI NRDA regulations at the Oak Ridge Reservation (ORR). The attendants were divided into three working groups to consider (1) administrative/legal requirements, (2) ecological assessments, and (3) the NRDA/economic evaluation process. This report supplies an overview of the DOI NRDA regulations as well as summaries of the consensus of each of the three working groups

  19. Using the virtual reality device Oculus Rift for neuropsychological assessment of visual processing capabilities.

    Science.gov (United States)

    Foerster, Rebecca M; Poth, Christian H; Behler, Christian; Botsch, Mario; Schneider, Werner X

    2016-11-21

    Neuropsychological assessment of human visual processing capabilities strongly depends on visual testing conditions including room lighting, stimuli, and viewing-distance. This limits standardization, threatens reliability, and prevents the assessment of core visual functions such as visual processing speed. Increasingly available virtual reality devices allow to address these problems. One such device is the portable, light-weight, and easy-to-use Oculus Rift. It is head-mounted and covers the entire visual field, thereby shielding and standardizing the visual stimulation. A fundamental prerequisite to use Oculus Rift for neuropsychological assessment is sufficient test-retest reliability. Here, we compare the test-retest reliabilities of Bundesen's visual processing components (visual processing speed, threshold of conscious perception, capacity of visual working memory) as measured with Oculus Rift and a standard CRT computer screen. Our results show that Oculus Rift allows to measure the processing components as reliably as the standard CRT. This means that Oculus Rift is applicable for standardized and reliable assessment and diagnosis of elementary cognitive functions in laboratory and clinical settings. Oculus Rift thus provides the opportunity to compare visual processing components between individuals and institutions and to establish statistical norm distributions.

  20. Developing and Implementing an Assessment Technique to Measure Linked Concepts

    Science.gov (United States)

    Ye, Li; Oueini, Razanne; Lewis, Scott E.

    2015-01-01

    The links students make among chemistry content is considered essential for a robust, enduring understanding in multiple learning theories. This article describes the development and implementation of an assessment technique, termed a Measure of Linked Concepts, designed to inform instructors on students' understanding of linking content…

  1. Best Implementation Practices: Disseminating New Assessment Technologies in a Juvenile Justice Agency

    Science.gov (United States)

    Young, Douglas; Moline, Karl; Farrell, Jill; Bierie, David

    2006-01-01

    Much has been written in recent years about advances in assessment technologies designed to aid decision making in the juvenile justice system. Adoption and implementation of this latest generation of actuarial tools, however, have lagged behind their development. Assessment in juvenile justice exemplifies the "science-practice gap" that…

  2. Cross-cultural adaptation of the assistive technology device - Predisposition assessment (ATD PA) for use in Brazil (ATD PA Br).

    Science.gov (United States)

    Alves, Ana Cristina de Jesus; Matsukura, Thelma Simões; Scherer, Marcia J

    2017-02-01

    The purpose of this study is to conduct a cross-cultural adaptation of the Assistive Technology Device Predisposition Assessment (ATD PA) for use in Brazil. The selection of the Assistive Technology Device Predisposition Assessment (ATD PA) was determined by previous literature reviews of articles published in 2014 and 2016 in six databases with the terms "assistive device" or "assistive technology" or "self-help device" combined with "evidence-based practice" or "framework" or "measurement scale" or "model and outcome assessment". This review indicated that the conceptual model of Assistive Technology (AT) most discussed in the literature was the Matching Person and Technology (MPT) model, and this finding determined the selection of ATD PA as an assessment within the MPT portfolio of measures. The procedures for cross-cultural adaptation were as follows: Equivalence of Concept, Semantic and Operational. Five experts were asked to translate 725 items and these translations were evaluated and a high level of agreement was demonstrated. The Portuguese version, Avaliação de Tecnologia Assistiva - Predisposição ao Uso - ATD PA Br, was derived from the original version in English (ATD PA). The ATD PA Br will support professionals and people with disabilities in Brazil to better select AT devices according to the clients' needs. Implications for rehabilitation Provides a systematic way of selecting assistive technology devices for the use of individuals with disabilities according to the Brazilian reality. A systematic way of selecting the assistive technology that can help decrease the abandonment of the assistive technology use. The use of the Matching Person and Technology theorical model and of the assessment ATD PA Br is essential to guide the researches and clinical practice in Brazil.

  3. Ultrasound assessment of the Essure contraceptive devices: is three-dimensional ultrasound really needed?

    Science.gov (United States)

    Paladini, Dario; Di Spiezio Sardo, Attilio; Coppola, Carmela; Zizolfi, Brunella; Pastore, Gaetano; Nappi, Carmine

    2015-01-01

    To evaluate the feasibility of 3-dimensional ultrasound (3DUS) for sonographic localization of Essure microinserts, comparing it with 2-dimensional ultrasound (2DUS) insofar as time to visualize the inserts and accuracy in determining their localization. Prospective study (Canadian Task Force classification II-2). University clinic. Twenty-seven consecutive women undergoing hysteroscopic Essure device placement. Essure microinserts were inserted in the outpatient hysteroscopy clinic following the manufacturer's recommendations, leaving from 3 to 8 loops of the inserts in the uterine cavity. In all patients, 2DUS and 3DUS were performed 3 months after the procedure. 2DUS was performed first; the device(s) were located, and their position was recorded. Then 3DUS scans were acquired, trying when possible to have both devices at least at a 45-degree angle with the insonation beam for optimal rendering on 3DUS. The OmniView method with volume contrast imaging was used to show the relationships of the microinserts within the uterine cavity when possible. To define the position of the Essure device in relation to the uterus and the salpinges, we used the classification developed by Legendre and colleagues. After sonographic evaluation all women underwent hysterosalpingography to assess the success of sterilization. Hysteroscopic insertion was successful in all patients, with 2 Essure devices placed in 25 patients and 1 device in 2 patients (due to previous salpingectomy performed because of ectopic pregnancy), for a total of 52 devices. One spontaneous late (within 3 months) expulsion of the device occurred; the device had migrated almost completely into the uterine cavity. At 3-month follow-up, all 51 correctly placed devices were easily observed at 2DUS (mean [SD] duration of the procedure, 2.25 [0.8] minutes). At 3DUS in 51 cases, the device was in perfect position (1+2+3) in 21 (41.2%), in position 2+3 in 14 (27.4%), and in position +3 in 16 (31.4%). Both microinserts

  4. Differences between Mothers' and Fathers' Ratings of Family Functioning with the Family Assessment Device: The Validity of Combined Parent Scores

    Science.gov (United States)

    Cooke, Dawson; Marais, Ida; Cavanagh, Robert; Kendall, Garth; Priddis, Lynn

    2015-01-01

    The psychometric properties of the General Functioning subscale of the McMaster Family Assessment Device were examined using the Rasch Model (N = 237 couples). Mothers' and fathers' ratings of the General Functioning subscale of the McMaster Family Assessment Device are recommended, provided these are analyzed separately. More than a quarter of…

  5. Practical design control implementation for medical devices

    CERN Document Server

    Justiniano, Jose

    2003-01-01

    Bringing together the concepts of design control and reliability engineering, this book is a must for medical device manufacturers. It helps them meet the challenge of designing and developing products that meet or exceed customer expectations and also meet regulatory requirements. Part One covers motivation for design control and validation, design control requirements, process validation and design transfer, quality system for design control, and measuring design control program effectiveness. Part Two discusses risk analysis and FMEA, designing-in reliability, reliability and design verific

  6. An Analysis of Campus Violence Threat Assessment Policy Implementation at Michigan Community Colleges

    Science.gov (United States)

    Panico, Russell T., Jr.

    2016-01-01

    This dissertation evaluated campus violence threat assessment policy and procedure implementation at the community college level of higher education. The importance of this topic was to provide a manageable and collaborative initiative for leadership at institutions of higher learning to identify, develop, implement, and evaluate a policy that can…

  7. A new device-independent dimension witness and its experimental implementation

    Science.gov (United States)

    Cai, Yu; Bancal, Jean-Daniel; Romero, Jacquiline; Scarani, Valerio

    2016-07-01

    A dimension witness is a criterion that sets a lower bound on the dimension needed to reproduce the observed data. Three types of dimension witnesses can be found in the literature: device-dependent ones, in which the bound is obtained assuming some knowledge on the state and the measurements; device-independent prepare-and-measure ones, that can be applied to any system including classical ones; and device-independent Bell-based ones, that certify the minimal dimension of some entangled systems. Here we consider the Collins-Gisin-Linden-Massar-Popescu Bell-type inequality for four outcomes. We show that a sufficiently high violation of this inequality witnesses d≥slant 4 and present a proof-of-principle experimental observation of such a violation. This presents a first experimental violation of the third type of dimension witness beyond qutrits.

  8. Dynamics of device innovation: implications for assessing value.

    Science.gov (United States)

    Gelijns, Annetine C; Russo, Mark J; Hong, Kimberly N; Brown, Lawrence D; Ascheim, Deborah D; Moskowitz, Alan J

    2013-10-01

    In recent years, there has been growing interest in evaluating the health and economic impact of medical devices. Payers increasingly rely on cost-effectiveness analyses in making their coverage decisions, and are adopting value-based purchasing initiatives. These analytic approaches, however, have been shaped heavily by their use in the pharmaceutical realm, and are ill-adapted to the medical device context. This study focuses on the development and evaluation of left ventricular assist devices (LVADs) to highlight the unique challenges involved in the design and conduct of device trials compared with pharmaceuticals. Devices are moving targets characterized by a much higher degree of post-introduction innovation and "learning by using" than pharmaceuticals. The cost effectiveness ratio of left ventricular assist devices for destination therapy, for example, decreased from around $600,000 per life year saved based on results from the pivotal trial to around $100,000 within a relatively short time period. These dynamics pose fundamental challenges to the evaluation enterprise as well as the policy-making world, which this paper addresses.

  9. Cognitive Inference Device for Activity Supervision in the Elderly

    Directory of Open Access Journals (Sweden)

    Nilamadhab Mishra

    2014-01-01

    Full Text Available Human activity, life span, and quality of life are enhanced by innovations in science and technology. Aging individual needs to take advantage of these developments to lead a self-regulated life. However, maintaining a self-regulated life at old age involves a high degree of risk, and the elderly often fail at this goal. Thus, the objective of our study is to investigate the feasibility of implementing a cognitive inference device (CI-device for effective activity supervision in the elderly. To frame the CI-device, we propose a device design framework along with an inference algorithm and implement the designs through an artificial neural model with different configurations, mapping the CI-device’s functions to minimise the device’s prediction error. An analysis and discussion are then provided to validate the feasibility of CI-device implementation for activity supervision in the elderly.

  10. New Monitoring Technology to Objectively Assess Adherence to Prescribed Footwear and Assistive Devices During Ambulatory Activity

    NARCIS (Netherlands)

    Bus, Sicco A.; Waaijman, Roelof; Nollet, Frans

    2012-01-01

    Bus SA, Waaijman R, Nollet F. New monitoring technology to objectively assess adherence to prescribed footwear and assistive devices during ambulatory activity. Arch Phys Med Rehabil 2012;93:2075-9. Objective: To assess the validity and feasibility of a new temperature-based adherence monitor to

  11. Joint Improvised-Threat Defeat Agency Needs to Improve Assessment and Documentation of Counter-Improvised Explosive Device Initiatives (Redacted)

    Science.gov (United States)

    2016-08-09

    E XC E L L E N C E Joint Improvised ‑Threat Defeat Agency Needs to Improve Assessment and Documentation of Counter‑ Improvised Explosive Device...USE ONLY DODIG-2016-120 (Project No. D2015-D000AE-0222.000) │ i Results in Brief Joint Improvised ‑Threat Defeat Agency Needs to Improve Assessment and...Documentation of Counter‑ Improvised Explosive Device Initiatives Visit us at www.dodig.mil Objective Our audit objective was to determine whether

  12. Implementation fidelity of a self-management course for epilepsy: method and assessment.

    Science.gov (United States)

    Wojewodka, G; Hurley, S; Taylor, S J C; Noble, A J; Ridsdale, L; Goldstein, L H

    2017-07-11

    Complex interventions such as self-management courses are difficult to evaluate due to the many interacting components. The way complex interventions are delivered can influence the effect they have for patients, and can impact the interpretation of outcomes of clinical trials. Implementation fidelity evaluates whether complex interventions are delivered according to protocol. Such assessments have been used for one-to-one psychological interventions; however, the science is still developing for group interventions. We developed and tested an instrument to measure implementation fidelity of a two-day self-management course for people with epilepsy, SMILE(UK). Using audio recordings, we looked at adherence and competence of course facilitators. Adherence was assessed by checklists. Competence was measured by scoring group interaction, an overall impression score and facilitator "didacticism". To measure "didacticism", we developed a novel way to calculate facilitator speech using computer software. Using this new instrument, implementation fidelity of SMILE(UK) was assessed on three modules of the course, for 28% of all courses delivered. Using the instrument for adherence, scores from two independent raters showed substantial agreement with weighted Kappa of 0.67 and high percent agreement of 81.2%. For didacticism, the results from both raters were highly correlated with an intraclass coefficient of 0.97 (p  50% of scored items received the maximum of 2 points) and high competence. Groups were interactive (mean score: 1.9-2.0 out of 2) and the overall impression was on average assessed as "good". Didacticism varied from 42% to 93% of total module time and was not associated with the other competence scores. The instrument devised to measure implementation fidelity was reproducible and easy to use. The courses for the SMILE(UK) study were delivered with a good level of adherence to protocol while not compromising facilitator competence. ISRCTN57937389 .

  13. An assessment of option B implementation for the prevention of ...

    African Journals Online (AJOL)

    An assessment of option B implementation for the prevention of mother to child transmission in Dschang, Cameroon: results from the DREAM (Drug Resource ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader).

  14. Development and Implementation of an Electronic Clinical Formative Assessment: Dental Faculty and Student Perspectives.

    Science.gov (United States)

    Kirkup, Michele L; Adams, Brooke N; Meadows, Melinda L; Jackson, Richard

    2016-06-01

    A traditional summative grading structure, used at Indiana University School of Dentistry (IUSD) for more than 30 years, was identified by faculty as outdated for assessing students' clinical performance. In an effort to change the status quo, a feedback-driven assessment was implemented in 2012 to provide a constructive assessment tool acceptable to both faculty and students. Building on the successful non-graded clinical evaluation employed at Baylor College of Dentistry, IUSD implemented a streamlined electronic formative feedback model (FFM) to assess students' daily clinical performance. An important addition to this evaluation tool was the inclusion of routine student self-assessment opportunities. The aim of this study was to determine faculty and student response to the new assessment instrument. Following training sessions, anonymous satisfaction surveys were examined for the three user groups: clinical faculty (60% response rate), third-year (D3) students (72% response rate), and fourth-year (D4) students (57% response rate). In the results, 70% of the responding faculty members preferred the FFM over the summative model; however, 61.8% of the D4 respondents preferred the summative model, reporting insufficient assessment time and low faculty participation. The two groups of students had different responses to the self-assessment component: 70.2% of the D4 respondents appreciated clinical self-assessment compared to 46% of the D3 respondents. Overall, while some components of the FFM assessment were well received, a phased approach to implementation may have facilitated a transition more acceptable to both faculty and students. Improvements are being made in an attempt to increase overall satisfaction.

  15. Do implementation strategies increase adherence to pain assessment in hospitals? A systematic review

    NARCIS (Netherlands)

    Ista, E.; Dijk, M. van; Achterberg, T. van

    2013-01-01

    OBJECTIVES: Pain assessment and reassessment is an essential part of the treatment of hospitalised patients and must be integrated in pain management protocols. Yet nurses' adherence to pain assessment recommendations is problematic. We sought to review the comparative evidence for implementation

  16. The use of a new automatic device for patients' assessment at Triage in Emergency Department

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2013-06-01

    Full Text Available Objectives: To assess time saving in an Emergency Department arising out of the introduction of automatic devices (Carescape™ V100 to measure vital signs compared to the manual devices. Methods: We performed a prospective, observational study of eligible patients referring to Sant’Andrea Hospital Emergency Department during the entire month of October 2009, randomly assigned into two groups. In the first group of 476 patients vital signs measurements were detected with manual devices, while in the second group of 477 patients with automatic device Carescape™ V100. Results: Data indicated that the comparison of the total time between the two groups gave a significant difference (1993 vs 1518 min, p < 0.001. No differences were found with respect to age, sex and priority codes. Significant differences were also found when comparing the subgroups of the same acuity categories: white codes 4.33 vs 2.27 (min, p < 0.05; green codes 4.28 vs 3.37 (min, p < 0.001; yellow codes 3.92 vs 2.72 (min, p < 0.001. Conclusions: Our data demonstrated a statistical significance between the two groups with a difference of 475 minutes spent in Triage procedures including vital signs measurements. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes. ABSTRACT of data concerning vital signs quality assessment, because we did not compare the two methods in the same patient and we did not correlate Triage priority evaluation with patients’ outcomes. In the future further studies should be specifically aimed to address this issue. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach to patient with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes.

  17. Implementation of quantum partial search with superconducting quantum interference device qudits in cavity QED

    International Nuclear Information System (INIS)

    Li Hong-Yi; Wu Chun-Wang; Chen Yu-Bo; Lin Yuan-Gen; Chen Ping-Xing; Li Cheng-Zu

    2013-01-01

    We present a method to implement the quantum partial search of the database separated into any number of blocks with qudits, D-level quantum systems. Compared with the partial search using qubits, our method needs fewer iteration steps and uses the carriers of the information more economically. To illustrate how to realize the idea with concrete physical systems, we propose a scheme to carry out a twelve-dimensional partial search of the database partitioned into three blocks with superconducting quantum interference devices (SQUIDs) in cavity QED. Through the appropriate modulation of the amplitudes of the microwave pulses, the scheme can overcome the non-identity of the cavity—SQUID coupling strengths due to the parameter variations resulting from the fabrication processes. Numerical simulation under the influence of the cavity and SQUID decays shows that the scheme could be achieved efficiently within current state-of-the-art technology

  18. Implementation of MPICH on Top of MP_Lite

    Energy Technology Data Exchange (ETDEWEB)

    Selvarajan, Shoba [Iowa State Univ., Ames, IA (United States)

    2002-01-01

    The goal of this thesis is to develop a new Channel Interface device for the MPICH Implementation of the MPI (Message Passing Interface) standard using MP_Lite. MP_Lite is a lightweight message-passing library that is not a full MPI implementation, but offers high performance MPICH (Message Passing Interface CHameleon) is a full implementation of the MPI standard that has the p4 library as the underlying communication device for TCP/IP networks. By integrating MP_Lite as a Channel Interface device in MPICH, a parallel programmer can utilize the full MPI implementation of MPICH as well as the high bandwidth offered by MP_Lite. There are several layers in the MPICH library where one can tie a new device. The Channel Interface is the lowest layer that requires very few functions to add a new device. By attaching MP_Lite to MPICH at the lowest level, the Channel Interface, almost all of the performance of the MP_Lite library can be delivered to the applications using MPICH. MP_Lite can be implemented either as a blocking or a non-blocking Channel Interface device. The performance was measured on two separate test clusters, the PC and the Alpha miniclusters, having Gigabit Ethernet connections. The PC cluster has two 1.8 GHz Pentium 4 PCs and the Alpha cluster has two 500 MHz Compaq DS20 workstations. Different network interface cards like Netgear, TrendNet and SysKonnect Gigabit Ethernet cards were used for the measurements. Both the blocking and non-blocking MPICH-MP_Lite Channel Interface devices perform close to raw TCP, whereas a performance loss of 25-30% is seen in the MPICH-p4 Channel Interface device for larger messages. The superior performance offered by the MPICH-MP_Lite device compared to the MPICH-p4 device can be easily seen on the SysKonnect cards using jumbo frames. The throughput curve also improves considerably by increasing the Eager/Rendezvous threshold.

  19. Three fundamental devices in one: a reconfigurable multifunctional device in two-dimensional WSe2

    Science.gov (United States)

    Dhakras, Prathamesh; Agnihotri, Pratik; Lee, Ji Ung

    2017-06-01

    The three pillars of semiconductor device technologies are (1) the p-n diode, (2) the metal-oxide-semiconductor field-effect transistor and (3) the bipolar junction transistor. They have enabled the unprecedented growth in the field of information technology that we see today. Until recently, the technological revolution for better, faster and more efficient devices has been governed by scaling down the device dimensions following Moore’s Law. With the slowing of Moore’s law, there is a need for alternative materials and computing technologies that can continue the advancement in functionality. Here, we describe a single, dynamically reconfigurable device that implements these three fundamental device functions. The device uses buried gates to achieve n- and p-channels and fits into a larger effort to develop devices with enhanced functionalities, including logic functions, over device scaling. As they are all surface conducting devices, we use one material parameter, the interface trap density of states, to describe the key figure-of-merit of each device.

  20. ASSESSMENT OF GUESTS’ PERCEPTION IN IMPLEMENTATION OF GREEN HOTEL IN SUPPORTING SUSTAINABLE TOURISM

    Directory of Open Access Journals (Sweden)

    I Gusti Ayu Oka - Suryawardani

    2016-03-01

    Full Text Available Tourism industry faced by threats in implementing sustainable tourism development. UNEP (United Nation Environmental Programme designs the concept to gain sustainable development through the program called the greening of industry which includes minimization of energy used, reducing green house emission, water consumption efficiency, waste management, reducing loss of biological diversity, and preserving cultural heritage. Dependency of tourism industry in using energy will impact in global warming and climate change which will lead to sustainability of the future of tourism development. The research was designed to assess guests’ perception on implementation of green hotel in supporting sustainable tourism in Bali. Research was undertaken in DKP hotel which is located in Kuta, Bali in the periods of April-June 2011. The hotel was choosen because DKP hotel is one of the hotels in Bali that has implemented the concept of green hotel in the hotel operational and was awarded as Green Hotel Award in the year of 2010. Sample was designed based on the minimum criteria on using Structural Equation Modelling (SEM. Respondents were guests who stay in the hotel and were willing to be interviewed and fill-in the questionnaires. The number of respondents were 121. Assessing guests’ perception was undertaken based on five-point Likert rating scale and relationship between variables which express level of concern of hotel management on the environment conservation, social-culture preservation and economic development were analyzed by using Software AMOS Version 23. The results show that assessment of guests’ perception in implementation of green hotel in the hotel operational through conservation of environment and preserving social and culture and its impact on economis development was positip and has resulted in supporting sustainable tourism. Environmental conservation awarenesss has been implemented through energy and water efficiency, waste

  1. Linking the Regulatory and Reimbursement Processes for Medical Devices : The Need for Integrated Assessments

    NARCIS (Netherlands)

    Ciani, Oriana; Wilcher, Britni; van Giessen, Anoukh; Taylor, Rod S.

    2017-01-01

    Much criticism has been directed at the licencing requirements for medical devices (MDs) as they often result in a lack of robust evidence to inform health technology assessment (HTA) decisions. To better understand the current international decisional framework on MD technologies, we undertook

  2. Assessment of a Newly Developed, Active Pneumatic-Driven, Sensorimotor Test and Training Device

    Directory of Open Access Journals (Sweden)

    Wolfram Haslinger

    2014-12-01

    Full Text Available The sensorimotor system (SMS plays an important role in sports and in every day movement. Several tools for assessment and training have been designed. Many of them are directed to specific populations, and have major shortcomings due to the training effect or safety. The aim of the present study was to design and assess a dynamic sensorimotor test and training device that can be adjusted for all levels of performance. The novel pneumatic-driven mechatronic device can guide the trainee, allow independent movements or disrupt the individual with unpredicted perturbations while standing on a platform. The test-reliability was evaluated using intraclass correlation coefficient (ICC. Subjects were required to balance their center of pressure (COP in a target circle (TITC. The time in TITC and the COP error (COPe were recorded for analysis. The results of 22 males and 14 females (23.7 ± 2.6 years showed good to excellent test–retest reliability. The newly designed Active Balance System (ABS was then compared with the Biodex Balance System SD® (BBS. The results of 15 females, 14 males (23.4 ± 1.6 years showed modest correlation in static and acceptable correlation in dynamic conditions, suggesting that ABS could be a reliable and comparable tool for dynamic balance assessments.

  3. Plasticity in memristive devices for Spiking Neural Networks

    Directory of Open Access Journals (Sweden)

    Sylvain eSaïghi

    2015-03-01

    Full Text Available Memristive devices present a new device technology allowing for the realization of compact nonvolatile memories. Some of them are already in the process of industrialization. Additionally, they exhibit complex multilevel and plastic behaviors, which make them good candidates for the implementation of artificial synapses in neuromorphic engineering. However, memristive effects rely on diverse physical mechanisms, and their plastic behaviors differ strongly from one technology to another. Here, we present measurements performed on different memristive devices and the opportunities that they provide. We show that they can be used to implement different learning rules whose properties emerge directly from device physics: real time or accelerated operation, deterministic or stochastic behavior, long term or short term plasticity. We then discuss how such devices might be integrated into a complete architecture. These results highlight that there is no unique way to exploit memristive devices in neuromorphic systems. Understanding and embracing device physics is the key for their optimal use.

  4. Synaptic electronics: materials, devices and applications.

    Science.gov (United States)

    Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip

    2013-09-27

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.

  5. Synaptic electronics: materials, devices and applications

    International Nuclear Information System (INIS)

    Kuzum, Duygu; Yu, Shimeng; Philip Wong, H-S

    2013-01-01

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented. (topical review)

  6. Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients

    Science.gov (United States)

    Syarif, A. N.; Bangun, K.

    2017-08-01

    Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.

  7. Interim report on the assessment of engineering issues for compact high-field ignition devices

    International Nuclear Information System (INIS)

    Flanagan, C.A.

    1986-04-01

    The engineering issues addressed at the workshop included the overall configuration, layout, and assembly; limiter and first-wall energy removal; magnet system structure design; fabricability; repairability; and costs. In performing the assessment, the primary features and characteristics of each concept under study were reviewed as representative of this class of ignition device. The emphasis was to understand the key engineering areas of concern for this class of device and deliberately not attempt to define an optimum design or to choose a best approach. The assessment concluded that compact ignition tokamaks, as represented by the three concepts under study, are feasible. A number of critical engineering issues were identified, and all appear to have tractable solutions. The engineering issues appear quite challenging, and to obtain increased confidence in the apparent design solutions requires completion of the next level of design detail, complemented by appropriate development programs and testing

  8. The influence of street level bureaucracy on the implementation of Strategic Environmental Assessment

    DEFF Research Database (Denmark)

    Kørnøv, Lone; Zhang, Jasmine; Christensen, Per

    2015-01-01

    A number of factors are critical to the implementation of measures identified through Strategic Environmental Assessment (SEA) processes. This paper addresses the challenge of implementation from a street level perspective and studies the role of planners and their use of discretion in the SEA...... implementation process: in which way might planners hinder or facilitate the implementation of SEA? Which coping mechanisms and discretions are deliberately or unconsciously developed and used by the planners? The paper reviews the literature on street level bureaucracy (SLB) in order to identify both factors...... influencing the implementation behaviour of street level bureaucrats and their coping mechanism when confronted with these factors. Based upon the SLB theory, a case study explores the SLB behaviour involved in the implementation of the SEA of the Copenhagen spatial plan. The analysis shows a surprisingly...

  9. On Emulation of Flueric Devices in Excitable Chemical Medium.

    Science.gov (United States)

    Adamatzky, Andrew

    2016-01-01

    Flueric devices are fluidic devices without moving parts. Fluidic devices use fluid as a medium for information transfer and computation. A Belousov-Zhabotinsky (BZ) medium is a thin-layer spatially extended excitable chemical medium which exhibits travelling excitation wave-fronts. The excitation wave-fronts transfer information. Flueric devices compute via jets interaction. BZ devices compute via excitation wave-fronts interaction. In numerical model of BZ medium we show that functions of key flueric devices are implemented in the excitable chemical system: signal generator, and, xor, not and nor Boolean gates, delay elements, diodes and sensors. Flueric devices have been widely used in industry since late 1960s and are still employed in automotive and aircraft technologies. Implementation of analog of the flueric devices in the excitable chemical systems opens doors to further applications of excitation wave-based unconventional computing in soft robotics, embedded organic electronics and living technologies.

  10. On Emulation of Flueric Devices in Excitable Chemical Medium.

    Directory of Open Access Journals (Sweden)

    Andrew Adamatzky

    Full Text Available Flueric devices are fluidic devices without moving parts. Fluidic devices use fluid as a medium for information transfer and computation. A Belousov-Zhabotinsky (BZ medium is a thin-layer spatially extended excitable chemical medium which exhibits travelling excitation wave-fronts. The excitation wave-fronts transfer information. Flueric devices compute via jets interaction. BZ devices compute via excitation wave-fronts interaction. In numerical model of BZ medium we show that functions of key flueric devices are implemented in the excitable chemical system: signal generator, and, xor, not and nor Boolean gates, delay elements, diodes and sensors. Flueric devices have been widely used in industry since late 1960s and are still employed in automotive and aircraft technologies. Implementation of analog of the flueric devices in the excitable chemical systems opens doors to further applications of excitation wave-based unconventional computing in soft robotics, embedded organic electronics and living technologies.

  11. An assessment of option B implementation for the prevention of ...

    African Journals Online (AJOL)

    An assessment of option B implementation for the prevention of mother to child transmission in Dschang, Cameroon: results from the DREAM (Drug Resource Enhancement against AIDS and ... Those with a CD4 count <350 cells/mm3 during pregnancy had the highest mortality risk (RR 2.53; 95% CL= 1.86-3.44). The HIV ...

  12. Assessing Server Fault Tolerance and Disaster Recovery Implementation in Thin Client Architectures

    National Research Council Canada - National Science Library

    Slaydon, Samuel L

    2007-01-01

    This thesis will focus on assessing server fault tolerance and disaster recovery procedures for thin-clients being implemented in smart classrooms and computer laboratories aboard the Naval Postgraduate School campus...

  13. SUPPORTING TEACHERS IN IMPLEMENTING FORMATIVE ASSESSMENT PRACTICES IN EARTH SYSTEMS SCIENCE

    Science.gov (United States)

    Harris, C. J.; Penuel, W. R.; Haydel Debarger, A.; Blank, J. G.

    2009-12-01

    An important purpose of formative assessment is to elicit student thinking to use in instruction to help all students learn and inform next steps in teaching. However, formative assessment practices are difficult to implement and thus present a formidable challenge for many science teachers. A critical need in geoscience education is a framework for providing teachers with real-time assessment tools as well as professional development to learn how to use formative assessment to improve instruction. Here, we describe a comprehensive support system, developed for our NSF-funded Contingent Pedagogies project, for addressing the challenge of helping teachers to use formative assessment to enhance student learning in middle school Earth Systems science. Our support system is designed to improve student understanding about the geosphere by integrating classroom network technology, interactive formative assessments, and contingent curricular activities to guide teachers from formative assessment to instructional decision-making and improved student learning. To accomplish this, we are using a new classroom network technology, Group Scribbles, in the context of an innovative middle-grades Earth Science curriculum called Investigating Earth Systems (IES). Group Scribbles, developed at SRI International, is a collaborative software tool that allows individual students to compose “scribbles” (i.e., drawings and notes), on “post-it” notes in a private workspace (a notebook computer) in response to a public task. They can post these notes anonymously to a shared, public workspace (a teacher-controlled large screen monitor) that becomes the centerpiece of group and class discussion. To help teachers implement formative assessment practices, we have introduced a key resource, called a teaching routine, to help teachers take advantage of Group Scribbles for more interactive assessments. Routine refers to a sequence of repeatable interactions that, over time, become

  14. Assessing implementation difficulties in tobacco use prevention and cessation counselling among dental providers

    Directory of Open Access Journals (Sweden)

    Murtomaa Heikki

    2011-05-01

    Full Text Available Abstract Background Tobacco use adversely affects oral health. Clinical guidelines recommend that dental providers promote tobacco abstinence and provide patients who use tobacco with brief tobacco use cessation counselling. Research shows that these guidelines are seldom implemented, however. To improve guideline adherence and to develop effective interventions, it is essential to understand provider behaviour and challenges to implementation. This study aimed to develop a theoretically informed measure for assessing among dental providers implementation difficulties related to tobacco use prevention and cessation (TUPAC counselling guidelines, to evaluate those difficulties among a sample of dental providers, and to investigate a possible underlying structure of applied theoretical domains. Methods A 35-item questionnaire was developed based on key theoretical domains relevant to the implementation behaviours of healthcare providers. Specific items were drawn mostly from the literature on TUPAC counselling studies of healthcare providers. The data were collected from dentists (n = 73 and dental hygienists (n = 22 in 36 dental clinics in Finland using a web-based survey. Of 95 providers, 73 participated (76.8%. We used Cronbach's alpha to ascertain the internal consistency of the questionnaire. Mean domain scores were calculated to assess different aspects of implementation difficulties and exploratory factor analysis to assess the theoretical domain structure. The authors agreed on the labels assigned to the factors on the basis of their component domains and the broader behavioural and theoretical literature. Results Internal consistency values for theoretical domains varied from 0.50 ('emotion' to 0.71 ('environmental context and resources'. The domain environmental context and resources had the lowest mean score (21.3%; 95% confidence interval [CI], 17.2 to 25.4 and was identified as a potential implementation difficulty. The domain emotion

  15. Assessing implementation difficulties in tobacco use prevention and cessation counselling among dental providers.

    Science.gov (United States)

    Amemori, Masamitsu; Michie, Susan; Korhonen, Tellervo; Murtomaa, Heikki; Kinnunen, Taru H

    2011-05-26

    Tobacco use adversely affects oral health. Clinical guidelines recommend that dental providers promote tobacco abstinence and provide patients who use tobacco with brief tobacco use cessation counselling. Research shows that these guidelines are seldom implemented, however. To improve guideline adherence and to develop effective interventions, it is essential to understand provider behaviour and challenges to implementation. This study aimed to develop a theoretically informed measure for assessing among dental providers implementation difficulties related to tobacco use prevention and cessation (TUPAC) counselling guidelines, to evaluate those difficulties among a sample of dental providers, and to investigate a possible underlying structure of applied theoretical domains. A 35-item questionnaire was developed based on key theoretical domains relevant to the implementation behaviours of healthcare providers. Specific items were drawn mostly from the literature on TUPAC counselling studies of healthcare providers. The data were collected from dentists (n = 73) and dental hygienists (n = 22) in 36 dental clinics in Finland using a web-based survey. Of 95 providers, 73 participated (76.8%). We used Cronbach's alpha to ascertain the internal consistency of the questionnaire. Mean domain scores were calculated to assess different aspects of implementation difficulties and exploratory factor analysis to assess the theoretical domain structure. The authors agreed on the labels assigned to the factors on the basis of their component domains and the broader behavioural and theoretical literature. Internal consistency values for theoretical domains varied from 0.50 ('emotion') to 0.71 ('environmental context and resources'). The domain environmental context and resources had the lowest mean score (21.3%; 95% confidence interval [CI], 17.2 to 25.4) and was identified as a potential implementation difficulty. The domain emotion provided the highest mean score (60%; 95% CI, 55

  16. Using a Mobile Device "App" and Proximal Remote Sensing Technologies to Assess Soil Cover Fractions on Agricultural Fields.

    Science.gov (United States)

    Laamrani, Ahmed; Pardo Lara, Renato; Berg, Aaron A; Branson, Dave; Joosse, Pamela

    2018-02-27

    Quantifying the amount of crop residue left in the field after harvest is a key issue for sustainability. Conventional assessment approaches (e.g., line-transect) are labor intensive, time-consuming and costly. Many proximal remote sensing devices and systems have been developed for agricultural applications such as cover crop and residue mapping. For instance, current mobile devices (smartphones & tablets) are usually equipped with digital cameras and global positioning systems and use applications (apps) for in-field data collection and analysis. In this study, we assess the feasibility and strength of a mobile device app developed to estimate crop residue cover. The performance of this novel technique (from here on referred to as "app" method) was compared against two point counting approaches: an established digital photograph-grid method and a new automated residue counting script developed in MATLAB at the University of Guelph. Both photograph-grid and script methods were used to count residue under 100 grid points. Residue percent cover was estimated using the app, script and photograph-grid methods on 54 vertical digital photographs (images of the ground taken from above at a height of 1.5 m) collected from eighteen fields (9 corn and 9 soybean, 3 samples each) located in southern Ontario. Results showed that residue estimates from the app method were in good agreement with those obtained from both photograph-grid and script methods (R² = 0.86 and 0.84, respectively). This study has found that the app underestimates the residue coverage by -6.3% and -10.8% when compared to the photograph-grid and script methods, respectively. With regards to residue type, soybean has a slightly lower bias than corn (i.e., -5.3% vs. -7.4%). For photos with residue <30%, the app derived residue measurements are within ±5% difference (bias) of both photograph-grid- and script-derived residue measurements. These methods could therefore be used to track the recommended minimum

  17. 77 FR 75173 - Comprehensive Assessment of the Process for the Review of Device Submissions; Request for Comments

    Science.gov (United States)

    2012-12-19

    ..., ``Independent Assessment of Review Process Management'', of the commitment letter entitled ``MDUFA Performance Goals and Procedures'' \\1\\ (MDUFA III Commitment Letter). The assessment will be conducted by an... performance commitments relating to the Medical Device User Fee Amendments of 2012 (MDUFA III), which...

  18. Geometry Optimization of an Overtopping Wave Energy Device Implemented into the New Breakwater of the Hanstholm Port Expansion

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Stratigaki, Vasiliki; Troch, Peter

    2012-01-01

    breakwater is 1.5 km and the water depth ranges approximately from 8.0 m up to 14 m with localized influences on the wave climate. The study is conducted numerically in order to present the expected power production and overall performance of the SSG breakwater in Hanstholm. The price par kWh is also......The study presented here describes the geometry optimization of the Sea wave Slot cone Generator (SSG) overtopping wave energy converter as part of the feasibility study for the implementation of the device in the development plan of Hanstholm harbour in Denmark. The total length of the new planned...

  19. Using Mobile Devices and the Adobe Connect Web Conferencing Tool in the Assessment of EFL Student Teacher Performance

    Science.gov (United States)

    Bolona Lopez, Maria del Carmen; Ortiz, Margarita Elizabeth; Allen, Christopher

    2015-01-01

    This paper describes a project to use mobile devices and video conferencing technology in the assessment of student English as a Foreign Language (EFL) teacher performance on teaching practice in Ecuador. With the increasing availability of mobile devices with video recording facilities, it has become easier for trainers to capture teacher…

  20. Implementation and assessment of improved models and options in TRAC-BF1

    International Nuclear Information System (INIS)

    Analytis, G.Th.

    1996-07-01

    A summary of modifications and options introduced in TRAC-BF1 is presented and it is shown that the predicting capabilities of the modified version of the core are greatly improved. These changes include the introduction of a different heat transfer package during reflooding, the implementation of a simple single-phase limit procedure for forcing the two phases to acquire the same velocity if one phase disappears, a close assessment of the annular flow interfacial shear correlation, implementation of a simple radiation model which seems to alleviate some numerical-oscillations problems induced by the existing highly complex model. Furthermore, different options were introduced and tested like upwinding some terms of the momentum equations (which seems to solve a number of problems reported in the past), the second upwind scheme for the convective terms of the phasic momentum equations and the implementation and assessment of a completely different annular flow interfacial shear correlation. The modified TRAC-BF1 is assessed against some bottom-flooding separate-effect experiments, a 'benchmark' top flooding simulation as well as against the TLTA test Nr. 6423. In the process of this task, the different options are assessed and discussed and is shown that the predictions of the modified code are physically sound and close to the measurements, while almost all the predicted variables are free of unphysical spurious oscillations. The modifications introduced solve a number of problems associated with the frozen version of the code and result in a version which can be confidently used for LB-LOCA analyses. (author) 19 figs., 16 refs

  1. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  2. Optimized ECC Implementation for Secure Communication between Heterogeneous IoT Devices

    Directory of Open Access Journals (Sweden)

    Leandro Marin

    2015-08-01

    Full Text Available The Internet of Things is integrating information systems, places, users and billions of constrained devices into one global network. This network requires secure and private means of communications. The building blocks of the Internet of Things are devices manufactured by various producers and are designed to fulfil different needs. There would be no common hardware platform that could be applied in every scenario. In such a heterogeneous environment, there is a strong need for the optimization of interoperable security. We present optimized elliptic curve Cryptography algorithms that address the security issues in the heterogeneous IoT networks. We have combined cryptographic algorithms for the NXP/Jennic 5148- and MSP430-based IoT devices and used them to created novel key negotiation protocol.

  3. Optimized ECC Implementation for Secure Communication between Heterogeneous IoT Devices.

    Science.gov (United States)

    Marin, Leandro; Pawlowski, Marcin Piotr; Jara, Antonio

    2015-08-28

    The Internet of Things is integrating information systems, places, users and billions of constrained devices into one global network. This network requires secure and private means of communications. The building blocks of the Internet of Things are devices manufactured by various producers and are designed to fulfil different needs. There would be no common hardware platform that could be applied in every scenario. In such a heterogeneous environment, there is a strong need for the optimization of interoperable security. We present optimized elliptic curve Cryptography algorithms that address the security issues in the heterogeneous IoT networks. We have combined cryptographic algorithms for the NXP/Jennic 5148- and MSP430-based IoT devices and used them to created novel key negotiation protocol.

  4. Implementation fidelity of a self-management course for epilepsy: method and assessment

    Directory of Open Access Journals (Sweden)

    G. Wojewodka

    2017-07-01

    Full Text Available Abstract Background Complex interventions such as self-management courses are difficult to evaluate due to the many interacting components. The way complex interventions are delivered can influence the effect they have for patients, and can impact the interpretation of outcomes of clinical trials. Implementation fidelity evaluates whether complex interventions are delivered according to protocol. Such assessments have been used for one-to-one psychological interventions; however, the science is still developing for group interventions. Methods We developed and tested an instrument to measure implementation fidelity of a two-day self-management course for people with epilepsy, SMILE(UK. Using audio recordings, we looked at adherence and competence of course facilitators. Adherence was assessed by checklists. Competence was measured by scoring group interaction, an overall impression score and facilitator “didacticism”. To measure “didacticism”, we developed a novel way to calculate facilitator speech using computer software. Using this new instrument, implementation fidelity of SMILE(UK was assessed on three modules of the course, for 28% of all courses delivered. Results Using the instrument for adherence, scores from two independent raters showed substantial agreement with weighted Kappa of 0.67 and high percent agreement of 81.2%. For didacticism, the results from both raters were highly correlated with an intraclass coefficient of 0.97 (p  50% of scored items received the maximum of 2 points and high competence. Groups were interactive (mean score: 1.9–2.0 out of 2 and the overall impression was on average assessed as “good”. Didacticism varied from 42% to 93% of total module time and was not associated with the other competence scores. Conclusion The instrument devised to measure implementation fidelity was reproducible and easy to use. The courses for the SMILE(UK study were delivered with a good level of adherence to

  5. Evidence Considerations for Mobile Devices in the Occupational Therapy Process

    Directory of Open Access Journals (Sweden)

    Kelly Erickson

    2015-04-01

    Full Text Available Mobile app-based device utilization, including smartphones and handheld tablets, suggests a need to evaluate evidence to guide selection and implementation of these devices in the occupational therapy process. The purpose of the research was to explore the current body of evidence in relation to mobile app-based devices and to identify factors in the use of these devices throughout the occupational therapy process. Following review of available occupational therapy profession guidelines, assistive technology literature, and available mobile device research, practitioners using mobile app-based devices in occupational therapy should consider three areas: client needs, practitioner competence, and device factors. The purpose of this guideline is to identify factors in the selection and use of mobile app-based devices throughout the occupational therapy process based on available evidence. Considerations for mobile device implementation during the occupational therapy process is addressed, including evaluating outcomes needs, matching device with the client, and identifying support needs of the client.

  6. Molecular cloning of Brevundimonas diminuta for efficacy assessment of reverse osmosis devices.

    Science.gov (United States)

    Donofrio, Robert; Saha, Ratul; Bestervelt, Lori; Bagley, Susan

    2012-06-01

    Brevundimonas diminuta is the test organism specified in the United States Environmental Protection Agency's (USEPA) reverse osmosis (RO) treatment device verification protocol. As non-selective growth medium is employed, enumeration of B. diminuta may be impaired due to interference by indigenous heterotrophic bacteria. Thus the microbial removal capability of the filtration system may be incorrectly assessed. As these treatment devices are used in emergency situations, the health of the public could be compromised. The objective of this study was to develop selective approaches for enumerating viable B. diminuta in test water. Two molecular approaches were investigated: expression of a kanamycin resistance gene and expression of a fluorescent protein gene. The USEPA protocol specifies a 0.3 μm cell size, so the expression of the selective markers were assessed following growth on media designed to induce this small cell diameter. The kan(R) strain was demonstrated to be equivalent to the wild type in cell dimension and survival following exposure to the test water. The kan(R) strain showed equivalent performance to the wild type in the RO protocol indicating that it is a viable alternative surrogate. By utilizing this strain, a more accurate validation of the RO system can be achieved.

  7. Advances in memristors, memristive devices and systems

    CERN Document Server

    Volos, Christos

    2017-01-01

    This book reports on the latest advances in and applications of memristors, memristive devices and systems. It gathers 20 contributed chapters by subject experts, including pioneers in the field such as Leon Chua (UC Berkeley, USA) and R.S. Williams (HP Labs, USA), who are specialized in the various topics addressed in this book, and covers broad areas of memristors and memristive devices such as: memristor emulators, oscillators, chaotic and hyperchaotic memristive systems, control of memristive systems, memristor-based min-max circuits, canonic memristors, memristive-based neuromorphic applications, implementation of memristor-based chaotic oscillators, inverse memristors, linear memristor devices, delayed memristive systems, flux-controlled memristive emulators, etc. Throughout the book, special emphasis is given to papers offering practical solutions and design, modeling, and implementation insights to address current research problems in memristors, memristive devices and systems. As such, it offers a va...

  8. Non-logic devices in logic processes

    CERN Document Server

    Ma, Yanjun

    2017-01-01

    This book shows readers how to design semiconductor devices using the most common and lowest cost logic CMOS processes.  Readers will benefit from the author’s extensive, industrial experience and the practical approach he describes for designing efficiently semiconductor devices that typically have to be implemented using specialized processes that are expensive, time-consuming, and low-yield. The author presents an integrated picture of semiconductor device physics and manufacturing techniques, as well as numerous practical examples of device designs that are tried and true.

  9. Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.

    Science.gov (United States)

    Jalal, Uddin M; Jin, Gyeong Jun; Shim, Joon S

    2017-12-19

    In this work, a disposable paper-plastic hybrid microfluidic lab-on-a-chip (LOC) has been developed and successfully applied for the colorimetric measurement of urine by the smartphone-based optical platform using a "UrineAnalysis" Android app. The developed device was cost-effectively implemented as a stand-alone hybrid LOC by incorporating the paper-based conventional reagent test strip inside the plastic-based LOC microchannel. The LOC device quantitatively investigated the small volume (40 μL) of urine analytes for the colorimetric reaction of glucose, protein, pH, and red blood cell (RBC) in integration with the finger-actuating micropump. On the basis of our experiments, the conventional urine strip showed large deviation as the reaction time goes by, because dipping the strip sensor in a bottle of urine could not control the reaction volume. By integrating the strip sensor in the LOC device for urine analysis, our device significantly improves the time-dependent inconstancy of the conventional dipstick-based urine strip, and the smartphone app used for image analysis enhances the visual assessment of the test strip, which is a major user concern for the colorimetric analysis in point-of-care (POC) applications. As a result, the user-friendly LOC, which is successfully implemented in a disposable format with the smartphone-based optical platform, may be applicable as an effective tool for rapid and qualitative POC urinalysis.

  10. Assessment of the Implementation of GNSS into Gliding

    Directory of Open Access Journals (Sweden)

    Tomáš Kubáč

    2017-11-01

    Full Text Available Global navigation satellite systems are increasingly part of our lives and many industries including aviation. Glider flying is no exception in this trend. Global navigation satellite systems were part of gliding since the early 1990s. First as official recording devices for simple evidence of sporting performances, then as navigation systems, anti-collision systems and emergency location transmitters. Development of recording application was initiated and supported by International Gliding Commission of World Air Sports Federation in way of certifications for flight recorders. The use of navigation and other modern instruments in gliders has brought many benefits but also risks. However, the advantages outweigh the disadvantages and these systems are now integral part of gliding. With this wide usage of global navigation satellite systems devices, there is great many possibilities how and in which way one can use these systems. Pilots must orient themselves in varied selection of products, which they can use to choose one solution, that fits him. Therefore, to find out how and if pilots use these devices, we created questionnaire survey among 143 Czech glider pilots. We found out, that 84% of them are using global navigation satellite systems devices for official record of flight and for navigation as well. More than half of pilots is using free, not built-in devices. Most common devices are mobile phones up to 5 inches of screen diagonal in combination with approved flight recorder without display. If pilots use mobile device for navigation, 52% of them is using one with Windows Mobile operating system, 33% use Android. Navigational software on these mobile devices is then almost tied between SeeYou Mobile, XCSoar and LK8000. Knowledge about usage preference of global navigation systems devices should help pilots with selection and overall orientation in subject.

  11. Implementation of Portfolio Assessment in a Competency-based Dental Hygiene Program.

    Science.gov (United States)

    Gadbury-Amyot, Cynthia C.; Holt, Lorie P.; Overman, Pamela R.; Schmidt, Colleen R.

    2000-01-01

    Describes the implementation of a portfolio assessment program in the dental hygiene program at the University of Missouri School of Dentistry. Tables provide examples of program competencies and related portfolio entries, the complete scoring rubric for portfolios, and the student portfolio evaluation survey. Concludes that although portfolio…

  12. Design and implementation of practical bidirectional texture function measurement devices focusing on the developments at the University of Bonn.

    Science.gov (United States)

    Schwartz, Christopher; Sarlette, Ralf; Weinmann, Michael; Rump, Martin; Klein, Reinhard

    2014-04-28

    Understanding as well as realistic reproduction of the appearance of materials play an important role in computer graphics, computer vision and industry. They enable applications such as digital material design, virtual prototyping and faithful virtual surrogates for entertainment, marketing, education or cultural heritage documentation. A particularly fruitful way to obtain the digital appearance is the acquisition of reflectance from real-world material samples. Therefore, a great variety of devices to perform this task has been proposed. In this work, we investigate their practical usefulness. We first identify a set of necessary attributes and establish a general categorization of different designs that have been realized. Subsequently, we provide an in-depth discussion of three particular implementations by our work group, demonstrating advantages and disadvantages of different system designs with respect to the previously established attributes. Finally, we survey the existing literature to compare our implementation with related approaches.

  13. Implementation of an ergonomics intervention in a Swedish flight baggage handling company—A process evaluation

    Science.gov (United States)

    Mathiassen, Svend Erik; Larsson, Johan; Kwak, Lydia

    2018-01-01

    Objective To conduct a process evaluation of the implementation of an ergonomics training program aimed at increasing the use of loading assist devices in flight baggage handling. Methods Feasibility related to the process items recruitment, reach, context, dose delivered (training time and content); dose received (participants’ engagement); satisfaction with training; intermediate outcomes (skills, confidence and behaviors); and barriers and facilitators of the training intervention were assessed by qualitative and quantitative methods. Results Implementation proved successful regarding dose delivered, dose received and satisfaction. Confidence among participants in the training program in using and talking about devices, observed use of devices among colleagues, and internal feedback on work behavior increased significantly (p<0.01). Main facilitators were self-efficacy, motivation, and perceived utility of training among the trainees. Barriers included lack of peer support, opportunities to observe and practice behaviors, and follow-up activities; as well as staff reduction and job insecurity. Conclusions In identifying important barriers and facilitators for a successful outcome, this study can help supporting the effectiveness of future interventions. Our results suggest that barriers caused by organizational changes may likely be alleviated by recruiting motivated trainees and securing strong organizational support for the implementation. PMID:29513671

  14. Implementation of stress assessments by occupational health nurses working in occupational health agencies and their confidence in conducting such assessments.

    Science.gov (United States)

    Ikeda, Chiseko; Saeki, Kazuko; Hirano, Michiyo

    2016-06-21

    Stress assessments are due to be conducted in December 2015. It is expected that there will be an increase in the number of private health agencies that provide stress assessment services and mental health care. This study aimed to clarify the current situation of and the factors related to stress assessments conducted by nurses in occupational health agencies. Nurses working full time were randomly selected from 60 organizations that were members of the National Federation of Industrial Health Organization. Self-administered questionnaires were sent out between November 2013 and January 2014. The questionnaire included the personal attributes of the participants, training programs, job contents, and how practical mental health care, including stress assessment, is. The study was approved by the ethics committees in the respective organizations. Out of the 162 questionnaires that were distributed, 89 (54.9%) were returned and 85 (53.1%) were valid for analysis. Stress assessments were conducted by 38.8% of the participants. With reference to their confidence in conducting stress assessments, "confidence and" 70.6%, respectively. The groups that conducted and did not conduct the stress assessments did not show any differences in the findings or other attributes. Further, the implementation of stress assessment was not associated with occupational health nurse (OHN) training, education, position, age, years of experience, attendance of lectures on mental health, etc. However, the confidence in conducting the assessment was related to age when dealing with cases on confidence stress assessment consultation in follow-up to the implementation of screening, such as stress, persons at high risk, and so on. Approximately 40% of the nurses were already conducting stress assessments, but most of them conducted such assessments about once a year and were not deeply involved in them. Approximately 70% of the nurses were confident in implementing stress assessments. Further

  15. Assessing the organizational context for EBP implementation: the development and validity testing of the Implementation Climate Scale (ICS).

    Science.gov (United States)

    Ehrhart, Mark G; Aarons, Gregory A; Farahnak, Lauren R

    2014-10-23

    Although the importance of the organizational environment for implementing evidence-based practices (EBP) has been widely recognized, there are limited options for measuring implementation climate in public sector health settings. The goal of this research was to develop and test a measure of EBP implementation climate that would both capture a broad range of issues important for effective EBP implementation and be of practical use to researchers and managers seeking to understand and improve the implementation of EBPs. Participants were 630 clinicians working in 128 work groups in 32 US-based mental health agencies. Items to measure climate for EBP implementation were developed based on past literature on implementation climate and other strategic climates and in consultation with experts on the implementation of EBPs in mental health settings. The sample was randomly split at the work group level of analysis; half of the sample was used for exploratory factor analysis (EFA), and the other half was used for confirmatory factor analysis (CFA). The entire sample was utilized for additional analyses assessing the reliability, support for level of aggregation, and construct-based evidence of validity. The EFA resulted in a final factor structure of six dimensions for the Implementation Climate Scale (ICS): 1) focus on EBP, 2) educational support for EBP, 3) recognition for EBP, 4) rewards for EBP, 5) selection for EBP, and 6) selection for openness. This structure was supported in the other half of the sample using CFA. Additional analyses supported the reliability and construct-based evidence of validity for the ICS, as well as the aggregation of the measure to the work group level. The ICS is a very brief (18 item) and pragmatic measure of a strategic climate for EBP implementation. It captures six dimensions of the organizational context that indicate to employees the extent to which their organization prioritizes and values the successful implementation of EBPs

  16. IMPLEMENTING HEALTH TECHNOLOGY ASSESSMENT-BASED RECOMMENDATIONS IN FINLAND

    DEFF Research Database (Denmark)

    Sihvo, Sinikka; Ikonen, Tuija; Mäkelä, Marjukka

    2017-01-01

    Objectives: The Managed Uptake of Medical Methods Program (MUMM) started 10 years ago as a joint venture of the Finnish Office for Health Technology Assessment (Finohta) and the twenty hospital districts in Finland. The aim is to offer information on the effectiveness, safety, organizational...... in decision making. Conclusions: HTA-based MUMM recommendations were well received by physicians but in practice they are less used than clinical practice guidelines. Short-form electronic surveys were a useful way of gathering information about awareness and implementation. The surveys also functioned...... as another method of informing key physicians about the recommendations....

  17. Assessment of the implementation risks for ALFRED demonstrator

    International Nuclear Information System (INIS)

    Constantin, M.; Diaconu, D.

    2016-01-01

    The risks related to the implementation of ALFRED demonstrator in Romania are discussed. The assessment is based on the risk matrix approach. Two groups of experts were used in the investigation: participants in FP7 ARCADIA projects and members of the FALCON consortium. The results consist of the hierarchy of the risks obtained based on the appreciations of the two groups. They are comparatively presented and discussed in terms of the identified critical risks and possible measures for prevention and mitigation. Additionally, some elements derived from the experience of similar project such as SUSEN and ELI-NP are discussed. (authors)

  18. Assessing organizational implementation context in the education sector: confirmatory factor analysis of measures of implementation leadership, climate, and citizenship.

    Science.gov (United States)

    Lyon, Aaron R; Cook, Clayton R; Brown, Eric C; Locke, Jill; Davis, Chayna; Ehrhart, Mark; Aarons, Gregory A

    2018-01-08

    A substantial literature has established the role of the inner organizational setting on the implementation of evidence-based practices in community contexts, but very little of this research has been extended to the education sector, one of the most common settings for the delivery of mental and behavioral health services to children and adolescents. The current study examined the factor structure, psychometric properties, and interrelations of an adapted set of pragmatic organizational instruments measuring key aspects of the organizational implementation context in schools: (1) strategic implementation leadership, (2) strategic implementation climate, and (3) implementation citizenship behavior. The Implementation Leadership Scale (ILS), Implementation Climate Scale (ICS), and Implementation Citizenship Behavior Scale (ICBS) were adapted by a research team that included the original scale authors and experts in the implementation of evidence-based practices in schools. These instruments were then administered to a geographically representative sample (n = 196) of school-based mental/behavioral health consultants to assess the reliability and structural validity via a series of confirmatory factor analyses. Overall, the original factor structures for the ILS, ICS, and ICBS were confirmed in the current sample. The one exception was poor functioning of the Rewards subscale of the ICS, which was removed in the final ICS model. Correlations among the revised measures, evaluated as part of an overarching model of the organizational implementation context, indicated both unique and shared variance. The current analyses suggest strong applicability of the revised instruments to implementation of evidence-based mental and behavioral practices in the education sector. The one poorly functioning subscale (Rewards on the ICS) was attributed to typical educational policies that do not allow for individual financial incentives to personnel. Potential directions for

  19. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  20. Designing systematic conservation assessments that promote effective implementation: best practice from South Africa.

    Science.gov (United States)

    Knight, Andrew T; Driver, Amanda; Cowling, Richard M; Maze, Kristal; Desmet, Philip G; Lombard, Amanda T; Rouget, Mathieu; Botha, Mark A; Boshoff, Andre F; Castley, J Guy; Goodman, Peter S; Mackinnon, Kathy; Pierce, Shirley M; Sims-Castley, Rebecca; Stewart, Warrick I; von Hase, Amrei

    2006-06-01

    Systematic conservation assessment and conservation planning are two distinct fields of conservation science often confused as one and the same. Systematic conservation assessment is the technical, often computer-based, identification of priority areas for conservation. Conservation planning is composed of a systematic conservation assessment coupled with processes for development of an implementation strategy and stakeholder collaboration. The peer-reviewed conservation biology literature abounds with studies analyzing the performance of assessments (e.g., area-selection techniques). This information alone, however can never deliver effective conservation action; it informs conservation planning. Examples of how to translate systematic assessment outputs into knowledge and then use them for "doing" conservation are rare. South Africa has received generous international and domestic funding for regional conservation planning since the mid-1990s. We reviewed eight South African conservation planning processes and identified key ingredients of best practice for undertaking systematic conservation assessments in a way that facilitates implementing conservation action. These key ingredients include the design of conservation planning processes, skills for conservation assessment teams, collaboration with stakeholders, and interpretation and mainstreaming of products (e.g., maps) for stakeholders. Social learning institutions are critical to the successful operationalization of assessments within broader conservation planning processes and should include not only conservation planners but also diverse interest groups, including rural landowners, politicians, and government employees.

  1. An electronic implementation of amoeba anticipation

    Science.gov (United States)

    Ziegler, Martin; Ochs, Karlheinz; Hansen, Mirko; Kohlstedt, Hermann

    2014-02-01

    In nature, the capability of memorizing environmental changes and recalling past events can be observed in unicellular organisms like amoebas. Pershin and Di Ventra have shown that such learning behavior can be mimicked in a simple memristive circuit model consisting of an LC (inductance capacitance) contour and a memristive device. Here, we implement this model experimentally by using an Ag/TiO2- x /Al memristive device. A theoretical analysis of the circuit is used to gain insight into the functionality of this model and to give advice for the circuit implementation. In this respect, the transfer function, resonant frequency, and damping behavior for a varying resistance of the memristive device are discussed in detail.

  2. Evaluation of an Efficient Method for Training Staff to Implement Stimulus Preference Assessments

    Science.gov (United States)

    Roscoe, Eileen M.; Fisher, Wayne W.

    2008-01-01

    We used a brief training procedure that incorporated feedback and role-play practice to train staff members to conduct stimulus preference assessments, and we used group-comparison methods to evaluate the effects of training. Staff members were trained to implement the multiple-stimulus-without-replacement assessment in a single session and the…

  3. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    Science.gov (United States)

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  4. Object tracking on mobile devices using binary descriptors

    Science.gov (United States)

    Savakis, Andreas; Quraishi, Mohammad Faiz; Minnehan, Breton

    2015-03-01

    With the growing ubiquity of mobile devices, advanced applications are relying on computer vision techniques to provide novel experiences for users. Currently, few tracking approaches take into consideration the resource constraints on mobile devices. Designing efficient tracking algorithms and optimizing performance for mobile devices can result in better and more efficient tracking for applications, such as augmented reality. In this paper, we use binary descriptors, including Fast Retina Keypoint (FREAK), Oriented FAST and Rotated BRIEF (ORB), Binary Robust Independent Features (BRIEF), and Binary Robust Invariant Scalable Keypoints (BRISK) to obtain real time tracking performance on mobile devices. We consider both Google's Android and Apple's iOS operating systems to implement our tracking approach. The Android implementation is done using Android's Native Development Kit (NDK), which gives the performance benefits of using native code as well as access to legacy libraries. The iOS implementation was created using both the native Objective-C and the C++ programing languages. We also introduce simplified versions of the BRIEF and BRISK descriptors that improve processing speed without compromising tracking accuracy.

  5. Multistate Memristive Tantalum Oxide Devices for Ternary Arithmetic

    Science.gov (United States)

    Kim, Wonjoo; Chattopadhyay, Anupam; Siemon, Anne; Linn, Eike; Waser, Rainer; Rana, Vikas

    2016-11-01

    Redox-based resistive switching random access memory (ReRAM) offers excellent properties to implement future non-volatile memory arrays. Recently, the capability of two-state ReRAMs to implement Boolean logic functionality gained wide interest. Here, we report on seven-states Tantalum Oxide Devices, which enable the realization of an intrinsic modular arithmetic using a ternary number system. Modular arithmetic, a fundamental system for operating on numbers within the limit of a modulus, is known to mathematicians since the days of Euclid and finds applications in diverse areas ranging from e-commerce to musical notations. We demonstrate that multistate devices not only reduce the storage area consumption drastically, but also enable novel in-memory operations, such as computing using high-radix number systems, which could not be implemented using two-state devices. The use of high radix number system reduces the computational complexity by reducing the number of needed digits. Thus the number of calculation operations in an addition and the number of logic devices can be reduced.

  6. Fibre Optic Communication Key Devices

    CERN Document Server

    Grote, Norbert

    2012-01-01

    The book gives an in-depth description of the key devices of current and next generation fibre optic communication networks. In particular, the book covers devices such as semiconductor lasers, optical amplifiers, modulators, wavelength filters, and detectors but the relevant properties of optical fibres as well. The presentations include the physical principles underlying the various devices, the technologies used for the realization of the different devices, typical performance characteristics and limitations, and development trends towards more advanced components are also illustrated. Thus the scope of the book spans relevant principles, state-of-the-art implementations, the status of current research and expected future components.

  7. Assessment of Selected Parameters of the Automatic Scarification Device as an Example of a Device for Sustainable Forest Management

    Directory of Open Access Journals (Sweden)

    Ryszard Tadeusiewicz

    2017-12-01

    Full Text Available Due to technological progress in forestry, seedlings with covered root systems—especially those grown in container nurseries—have become increasingly important in forest nursery production. One the trees that is most commonly grown this way is the common oak (Quercus robur L.. For an acorn to be sown in a container, it is necessary to remove its upper part during mechanical scarification, and evaluate its sowing suitability. At present, this is mainly done manually and by visual assessment. The low effectiveness of this method of acorn preparation has encouraged a search for unconventional solutions. One of them is the use of an automated device that consists of a computer vision-based module. For economic reasons related to the cost of growing seedlings in container nurseries, it is beneficial to minimize the contribution of unhealthy seeds. The maximum accuracy, which is understood as the number of correct seed diagnoses relative to the total number of seeds being assessed, was adopted as a criterion for choosing a separation threshold. According to the method proposed, the intensity and red components of the images of scarified acorns facilitated the best results in terms of the materials examined during the experiment. On average, a 10% inaccuracy of separation was observed. A secondary outcome of the presented research is an evaluation of the ergonomic parameters of the user interface that is attached to the unit controlling the device when it is running in its autonomous operation mode.

  8. Effective vulnerability assessments for physical security devices, systems, and programs

    International Nuclear Information System (INIS)

    Johnston, R.G.; Garcia, A.R.E.

    2002-01-01

    Full text: The efficacy of devices, systems, and programs used for physical security depend critically on having periodic and effective vulnerability assessments. Effective vulnerability assessments, in turn, require certain conditions and attributes. These include: a proper understanding of their purpose; not confusing vulnerability assessments with other kinds of metrics, analyses, tests, and security exercises; the view that vulnerabilities are inevitable, and that finding them is good news (since they can then be mitigated), not bad news; rejection of findings of no vulnerabilities; avoidance of mere 'compliance mode' rubber stamping; the use of the proper outside, independent, imaginative personnel; psychologically predisposed to finding and demonstrating problems; the absence of conflicts of interest; no unrealistic constraints on the possible attack tools, procedures, personnel, or strategies; efforts to not just find and demonstrate vulnerabilities, but also to suggest possible countermeasures; proper context; input and buy-in from ALL facility security personnel, especially low-level personnel; emphasis on the simplest, most relevant attacks first; no underestimation of potential adversaries; consideration of fault analysis attacks; awareness of Rohrbach's Maxim and Shannon's Maxim. In addition to these factors, we will cover some of the complex issues and problems associated with the design of vulnerability assessments. There will also be suggestions on how to conduct effective vulnerability assessments on a severely limited budget. We will conclude with a discussion of both conventional and unconventional ways of reporting results. (author)

  9. [Theoretical and practical assessment of Lille general practice and pharmacy students' knowledge about use of inhaler devices for asthma control].

    Science.gov (United States)

    Veylon, P; Rochoy, M; Gautier, S; Wallaert, B; Berkhout, C

    2018-04-01

    Asthma is a potentially serious chronic respiratory disease impacting patients quality of life. Satisfactory control requires proper use of inhaled devices. This study assesses general medical residents and pharmacy students knowledge about proper use of inhaled asthma devices. We evaluated knowledge of 43 general practice students and 43 pharmacy students in Lille for three inhaler devices (metered-dose inhaler, Turbuhaler ® and Diskus ® ) during individual interviews. Students were assessed on 8 proper use criterias for each device. General practice and pharmacy students are unfamiliar with proper use of inhaler devices. However, pharmacy students get better average scores than general practice students for all devices included in this study: 6.3/8 respected criterias against 5/8 for metered-dose inhaler; 5.3/8 against 3.2/8 for Turbuhaler ® ; and 6/8 against 4.3/8 for Diskus ® . Pharmacy students more frequently perform a demonstration of proper use to patients when a device is first prescribed or when a prescription is renewed; general practice students more frequently ask patients themselves to perform a demonstration of proper use. Introducing trainings workshops for inhaler devices to pharmacy and general practice students appears appropriate in order to promote therapeutic patient education, to increase asthma control and better patients life quality. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  10. SU-E-T-181: Clinical Implementation of Task Group 176

    Energy Technology Data Exchange (ETDEWEB)

    Burgdorf, B [University of Pennsylvania, Philadelphia, PA (United States); Yeager, C; Zhou, F; Hand, C [Albert Einstein Medical Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: The implementation of TG-176 with regards to immobilization devices and couch tops as they effect dosimetric treatment planning. Methods: The external devices used clinically were scanned to measure their HU values. Plans were created in the Eclipse treatment planning system (TPS) using these devices, one that accounted for the correct HU value of the each device and another that did not include the device as a structure. A dose subtraction was performed between the two plans to evaluate the dosimetric differences. The metrics used for evaluation included attenuation and surface dose. Plan parameters were varied to evaluate the impact of the devices in different clinical scenarios. Results: While the exact HU values of our results are clinic-dependent, the protocol being implemented is widely applicable. We recommend a four step process for implementing this task group. First, physics should scan each treatment device to determine accurate HU values. Second, CT therapists should include in the setup note which table top was used during patient CT simulation and are asked to make immobilization devices as uniform in thickness as possible. Therapists should also index the devices whenever possible so beam will traverse the same area of the device. Third, the dosimetrist should manually correct the HU value for any external device, including the couch. For H&N cases, the rails must be removed from the couch structure. When rails are used during treatments, it is important to make note of their exact position in the setup notes. Finally, physicians should be made aware that there could be changes in surface doses depending on whether or not immobilization devices or couch tops are in the beam path. Conclusion: The protocol outlined above was implemented to reduce the errors that arise from ignoring effects of external devices, thus ensuring safer, more accurate patient treatments.

  11. Implementing Trauma-Informed Partner Violence Assessment in Family Planning Clinics.

    Science.gov (United States)

    Decker, Michele R; Flessa, Sarah; Pillai, Ruchita V; Dick, Rebecca N; Quam, Jamie; Cheng, Diana; McDonald-Mosley, Raegan; Alexander, Kamila A; Holliday, Charvonne N; Miller, Elizabeth

    2017-09-01

    Intimate partner violence (IPV) and reproductive coercion (RC) are associated with poor reproductive health. Little is known about how family planning clinics implement brief IPV/RC assessment interventions in practice. We describe the uptake and impact of a brief, trauma-informed, universal IPV/RC assessment and education intervention. Intervention implementation was evaluated via a mixed methods study among women ages 18 and up receiving care at one of two family planning clinics in greater Baltimore, MD. This mixed methods study entailed a quasi-experimental, single group pretest-posttest study with family planning clinic patients (baseline and exit survey n = 132; 3-month retention n = 68; retention rate = 52%), coupled with qualitative interviews with providers and patients (total n = 35). Two thirds (65%) of women reported receiving at least one element of the intervention on their exit survey immediately following the clinic-visit. Patients reported that clinic-based IPV assessment is helpful, irrespective of IPV history. Relative to those who reported neither, participants who received either intervention element reported greater perceived caring from providers, confidence in provider response to abusive relationships, and knowledge of IPV-related resources at follow-up. Providers and patients alike described the educational card as a valuable tool. Participants described trade-offs of paper versus in-person, electronic medical record-facilitated screening, and patient reluctance to disclose current situations of abuse. In real-world family planning clinic settings, a brief assessment and support intervention was successful in communicating provider caring and increasing knowledge of violence-related resources, endpoints previously deemed valuable by IPV survivors. Results emphasize the merit of universal education in IPV/RC clinical interventions over seeking IPV disclosure.

  12. Assessing Culture and Climate of Federally Qualified Health Centers: A Plan for Implementing Behavioral Health Interventions.

    Science.gov (United States)

    Kramer, Teresa L; Drummond, Karen L; Curran, Geoffrey M; Fortney, John C

    2017-01-01

    This study examines organizational factors relating to climate and culture that might facilitate or impede the implementation of evidence-based practices (EBP) targeting behavioral health in federally qualified health centers (FQHCs). Employees at six FQHCs participating in an evidence-based quality improvement (EBQI) initiative for mood disorders and alcohol abuse were interviewed (N=32) or surveyed using the Organizational Context Survey (OCS) assessing culture and climate (N=64). The FQHCs scored relatively well on proficiency, a previously established predictor of successful EBP implementation, but also logged high scores on scales assessing rigidity and resistance, which may hinder implementation. Qualitative data contextualized scores on FQHC culture and climate dimensions. Results suggest that the unique culture of FQHCs may influence implementation of evidence-based behavioral health interventions.

  13. Predicting Pre-Service Teachers' Intention of Implementing Peer Assessment for Low-Achieving Students

    Science.gov (United States)

    Yim, Su Yon; Cho, Young Hoan

    2016-01-01

    Despite the benefits of peer assessment, many teachers are not willing to implement it, particularly for low-achieving students. This study used the theory of planned behaviour to predict pre-service teachers' intention to use peer assessment for low-achieving students. A total of 229 pre-service teachers in Singapore participated in the survey…

  14. Developing and implementing an oral care policy and assessment tool.

    LENUS (Irish Health Repository)

    Stout, Michelle

    2012-01-09

    Oral hygiene is an essential aspect of nursing care. Poor oral care results in patients experiencing pain and discomfort, puts individuals at risk of nutritional deficiency and infection, and has an adverse effect on quality of life. This article describes how an oral care policy and assessment tool were updated to ensure the implementation of evidence-based practice at one hospital in the Republic of Ireland.

  15. Enhancing implementation security of QKD

    Science.gov (United States)

    Tamaki, Kiyoshi

    2017-10-01

    Quantum key distribution (QKD) can achieve information-theoretic security, which is a provable security against any eavesdropping, given that all the devices the sender and the receiver employ operate exactly as the theory of security requires. Unfortunately, however, it is difficult for practical devices to meet all such requirements, and therefore more works have to be done toward guaranteeing information-theoretic security in practice, i.e., implementation security. In this paper, we review our recent efforts to enhance implementation security. We also have a brief look at a flaw in security proofs and present how to fix it.

  16. WIH-based IEEE 802.11 ECG monitoring implementation.

    Science.gov (United States)

    Moein, A; Pouladian, M

    2007-01-01

    New wireless technologies make possible the implementation of high level integration wireless devices which allow the replacement of traditional large wired monitoring devices. It offers new functionalities to physicians and will reduce the costs. Among these functionalities, biomedical signals can be sent to other devices (PDA, PC . . . ) or processing centers, without restricting the patients' mobility. This article discusses the WIH (Ward-In-Hand) structure and the software required for its implementation before an operational example is presented with its results. The aim of this project is the development and implementation of a reduced size electrocardiograph based on IEEE 802.11 with high speed and more accuracy, which allows wireless monitoring of patients, and the insertion of the information into the Wi-Fi hospital networks.

  17. Electronic SSKIN pathway: reducing device-related pressure ulcers.

    Science.gov (United States)

    Campbell, Natalie

    2016-08-11

    This article describes how an interprofessional project in a London NHS Foundation Trust was undertaken to develop an intranet-based medical device-related pressure ulcer prevention and management pathway for clinical staff working across an adult critical care directorate, where life-threatening events require interventions using medical devices. The aim of this project was to improve working policies and processes to define key prevention strategies and provide clinicians with a clear, standardised approach to risk and skin assessment, equipment use, documentation and reporting clinical data using the Trust's CareVue (electronic medical records), Datix (incident reporting and risk-management tool) and eTRACE (online clinical protocol ordering) systems. The process included the development, trial and local implementation of the pathway using collaborative teamwork and the SSKIN care bundle tool. The experience of identifying issues, overcoming challenges, defining best practice and cascading SSKIN awareness training is shared.

  18. Risk assessment for enterprise resource planning (ERP) system implementations: a fault tree analysis approach

    Science.gov (United States)

    Zeng, Yajun; Skibniewski, Miroslaw J.

    2013-08-01

    Enterprise resource planning (ERP) system implementations are often characterised with large capital outlay, long implementation duration, and high risk of failure. In order to avoid ERP implementation failure and realise the benefits of the system, sound risk management is the key. This paper proposes a probabilistic risk assessment approach for ERP system implementation projects based on fault tree analysis, which models the relationship between ERP system components and specific risk factors. Unlike traditional risk management approaches that have been mostly focused on meeting project budget and schedule objectives, the proposed approach intends to address the risks that may cause ERP system usage failure. The approach can be used to identify the root causes of ERP system implementation usage failure and quantify the impact of critical component failures or critical risk events in the implementation process.

  19. Using a Mobile Device “App” and Proximal Remote Sensing Technologies to Assess Soil Cover Fractions on Agricultural Fields

    Directory of Open Access Journals (Sweden)

    Ahmed Laamrani

    2018-02-01

    Full Text Available Quantifying the amount of crop residue left in the field after harvest is a key issue for sustainability. Conventional assessment approaches (e.g., line-transect are labor intensive, time-consuming and costly. Many proximal remote sensing devices and systems have been developed for agricultural applications such as cover crop and residue mapping. For instance, current mobile devices (smartphones & tablets are usually equipped with digital cameras and global positioning systems and use applications (apps for in-field data collection and analysis. In this study, we assess the feasibility and strength of a mobile device app developed to estimate crop residue cover. The performance of this novel technique (from here on referred to as “app” method was compared against two point counting approaches: an established digital photograph-grid method and a new automated residue counting script developed in MATLAB at the University of Guelph. Both photograph-grid and script methods were used to count residue under 100 grid points. Residue percent cover was estimated using the app, script and photograph-grid methods on 54 vertical digital photographs (images of the ground taken from above at a height of 1.5 m collected from eighteen fields (9 corn and 9 soybean, 3 samples each located in southern Ontario. Results showed that residue estimates from the app method were in good agreement with those obtained from both photograph–grid and script methods (R2 = 0.86 and 0.84, respectively. This study has found that the app underestimates the residue coverage by −6.3% and −10.8% when compared to the photograph-grid and script methods, respectively. With regards to residue type, soybean has a slightly lower bias than corn (i.e., −5.3% vs. −7.4%. For photos with residue <30%, the app derived residue measurements are within ±5% difference (bias of both photograph-grid- and script-derived residue measurements. These methods could therefore be used to track

  20. The Assessment, Development, Assurance Pharmacist's Tool (ADAPT) for ensuring quality implementation of health promotion programs.

    Science.gov (United States)

    Truong, Hoai-An; Taylor, Catherine R; DiPietro, Natalie A

    2012-02-10

    To develop and validate the Assessment, Development, Assurance Pharmacist's Tool (ADAPT), an instrument for pharmacists and student pharmacists to use in developing and implementing health promotion programs. The 36-item ADAPT instrument was developed using the framework of public health's 3 core functions (assessment, policy development, and assurance) and 10 essential services. The tool's content and usage was assessed and conducted through peer-review and initial validity testing processes. Over 20 faculty members, preceptors, and student pharmacists at 5 institutions involved in planning and implementing health promotion initiatives reviewed the instrument and conducted validity testing. The instrument took approximately 15 minutes to complete and the findings resulted in changes and improvements to elements of the programs evaluated. The ADAPT instrument fills a need to more effectively plan, develop, implement, and evaluate pharmacist-directed public health programs that are evidence-based, high-quality, and compliant with laws and regulations and facilitates documentation of pharmacists' contributions to public health.

  1. Implementation and role of device management Solutions to the end users

    OpenAIRE

    Egbeni, Victor Kanayo

    2009-01-01

    This research is based on consumer complaints with respect to recently purchased consumer electronics. This research document will investigate the instances of development and device management as a tool used to aid consumer and manage consumer’s mobile products in order to resolve issues in or before the consumers is aware one exists. The problem at the present time is that mobile devices are becoming very advanced pieces of technology, and not all manufacturers and network providers have ke...

  2. Implementation of KRoC on Analog Devices' "SHARC" DSP

    NARCIS (Netherlands)

    Otten, G.W.; Schwirtz, M.H.; Schwirtz, Marcellinus H.; Bruis, R.; Bruis, R.; Broenink, Johannes F.; Bakkers, André; O'Neill, Brian C.

    1996-01-01

    This paper summarises the experiences gained at the Control Laboratory of the University of Twente in porting the Kent Retargetable occam Compiler -KroC -to the Analog Devices' ADSP21060 SHARC Digital Signal Processor. The choice of porting the KRoC to the DSP processor was in our view both a

  3. Use of a mobile device by nursing home residents for long-term care comprehensive geriatric self-assessment: a feasibility study.

    Science.gov (United States)

    Huang, Fanpin; Chang, Polun; Hou, I-Ching; Tu, Ming-Hsiang; Lan, Chung-Fu

    2015-01-01

    Long-term-care comprehensive geriatric assessments, such as the Minimum Data Set 3.0, are used to evaluate the clinical, psychological, and personal status of residents in long-term-care nursing facilities. Nursing staff conducts assessment interviews, thereby increasing the workload of nurses and the cost of patient care. This study explored the ability of nursing home residents to use two different mobile devices for a geriatric self-assessment. Study participants were residents of long-term-care nursing homes. A modified Minimum Data Set 3.0 was converted to a format for use with a 6-inch mobile pad and a 3.7-inch mobile smartphone. The survey completion rate and the response time were measured. A Technology Assessment Model questionnaire analyzed the participants' experience. All participants were able to use a 6-inch pad, with an average completion rate of 92.9% and an average time for completion of 21 minutes. Only 20% of the participants could complete the assessment with the 3.7-inch smartphone. The participants found the 6-inch pad easier to use than the 3.7-inch smartphone. This exploratory study suggests that nursing home residents are able to use a mobile device to perform a geriatric self-assessment and delineates the importance of the ergonomics of the device.

  4. Implementation outcome assessment instruments used in physical healthcare settings and their measurement properties: a systematic review protocol.

    Science.gov (United States)

    Khadjesari, Zarnie; Vitoratou, Silia; Sevdalis, Nick; Hull, Louise

    2017-10-08

    Over the past 10 years, research into methods that promote the uptake, implementation and sustainability of evidence-based interventions has gathered pace. However, implementation outcomes are defined in different ways and assessed by different measures; the extent to which these measures are valid and reliable is unknown. The aim of this systematic review is to identify and appraise studies that assess the measurement properties of quantitative implementation outcome instruments used in physical healthcare settings, to advance the use of precise and accurate measures. The following databases will be searched from inception to March 2017: MEDLINE, EMBASE, PsycINFO, CINAHL and the Cochrane Library. Grey literature will be sought via HMIC, OpenGrey, ProQuest for theses and Web of Science Conference Proceedings Citation Index-Science. Reference lists of included studies and relevant reviews will be hand searched. Three search strings will be combined to identify eligible studies: (1) implementation literature, (2) implementation outcomes and (3) measurement properties. Screening of titles, abstracts and full papers will be assessed for eligibility by two reviewers independently and any discrepancies resolved via consensus with the wider team. The methodological quality of the studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. A set of bespoke criteria to determine the quality of the instruments will be used, and the relationship between instrument usability and quality will be explored. Ethical approval is not necessary for systematic review protocols. Researchers and healthcare professionals can use the findings of this systematic review to guide the selection of implementation outcomes instruments, based on their psychometric quality, to assess the impact of their implementation efforts. The findings will also provide a useful guide for reviewers of papers and grants to determine the

  5. Implementation outcome assessment instruments used in physical healthcare settings and their measurement properties: a systematic review protocol

    Science.gov (United States)

    Vitoratou, Silia; Sevdalis, Nick; Hull, Louise

    2017-01-01

    Introduction Over the past 10 years, research into methods that promote the uptake, implementation and sustainability of evidence-based interventions has gathered pace. However, implementation outcomes are defined in different ways and assessed by different measures; the extent to which these measures are valid and reliable is unknown. The aim of this systematic review is to identify and appraise studies that assess the measurement properties of quantitative implementation outcome instruments used in physical healthcare settings, to advance the use of precise and accurate measures. Methods and analysis The following databases will be searched from inception to March 2017: MEDLINE, EMBASE, PsycINFO, CINAHL and the Cochrane Library. Grey literature will be sought via HMIC, OpenGrey, ProQuest for theses and Web of Science Conference Proceedings Citation Index-Science. Reference lists of included studies and relevant reviews will be hand searched. Three search strings will be combined to identify eligible studies: (1) implementation literature, (2) implementation outcomes and (3) measurement properties. Screening of titles, abstracts and full papers will be assessed for eligibility by two reviewers independently and any discrepancies resolved via consensus with the wider team. The methodological quality of the studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. A set of bespoke criteria to determine the quality of the instruments will be used, and the relationship between instrument usability and quality will be explored. Ethics and dissemination Ethical approval is not necessary for systematic review protocols. Researchers and healthcare professionals can use the findings of this systematic review to guide the selection of implementation outcomes instruments, based on their psychometric quality, to assess the impact of their implementation efforts. The findings will also provide a useful guide for

  6. Performance characteristics of a novel blood bag in-line closure device and subsequent product quality assessment

    Science.gov (United States)

    Serrano, Katherine; Levin, Elena; Culibrk, Brankica; Weiss, Sandra; Scammell, Ken; Boecker, Wolfgang F; Devine, Dana V

    2010-01-01

    BACKGROUND In high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers. STUDY DESIGN AND METHODS The consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis. RESULTS The use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control. CONCLUSIONS The CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality. PMID:20529007

  7. Programmable ubiquitous telerobotic devices

    Science.gov (United States)

    Doherty, Michael; Greene, Matthew; Keaton, David; Och, Christian; Seidl, Matthew L.; Waite, William; Zorn, Benjamin G.

    1997-12-01

    We are investigating a field of research that we call ubiquitous telepresence, which involves the design and implementation of low-cost robotic devices that can be programmed and operated from anywhere on the Internet. These devices, which we call ubots, can be used for academic purposes (e.g., a biologist could remote conduct a population survey), commercial purposes (e.g., a house could be shown remotely by a real-estate agent), and for recreation and education (e.g., someone could tour a museum remotely). We anticipate that such devices will become increasingly common due to recent changes in hardware and software technology. In particular, current hardware technology enables such devices to be constructed very cheaply (less than $500), and current software and network technology allows highly portable code to be written and downloaded across the Internet. In this paper, we present our prototype system architecture, and the ubot implementation we have constructed based on it. The hardware technology we use is the handy board, a 6811-based controller board with digital and analog inputs and outputs. Our software includes a network layer based on TCP/IP and software layers written in Java. Our software enables users across the Internet to program the behavior of the vehicle and to receive image feedback from a camera mounted on it.

  8. Development and implementation of a Bayesian-based aquifer vulnerability assessment in Florida

    Science.gov (United States)

    Arthur, J.D.; Wood, H.A.R.; Baker, A.E.; Cichon, J.R.; Raines, G.L.

    2007-01-01

    The Florida Aquifer Vulnerability Assessment (FAVA) was designed to provide a tool for environmental, regulatory, resource management, and planning professionals to facilitate protection of groundwater resources from surface sources of contamination. The FAVA project implements weights-of-evidence (WofE), a data-driven, Bayesian-probabilistic model to generate a series of maps reflecting relative aquifer vulnerability of Florida's principal aquifer systems. The vulnerability assessment process, from project design to map implementation is described herein in reference to the Floridan aquifer system (FAS). The WofE model calculates weighted relationships between hydrogeologic data layers that influence aquifer vulnerability and ambient groundwater parameters in wells that reflect relative degrees of vulnerability. Statewide model input data layers (evidential themes) include soil hydraulic conductivity, density of karst features, thickness of aquifer confinement, and hydraulic head difference between the FAS and the watertable. Wells with median dissolved nitrogen concentrations exceeding statistically established thresholds serve as training points in the WofE model. The resulting vulnerability map (response theme) reflects classified posterior probabilities based on spatial relationships between the evidential themes and training points. The response theme is subjected to extensive sensitivity and validation testing. Among the model validation techniques is calculation of a response theme based on a different water-quality indicator of relative recharge or vulnerability: dissolved oxygen. Successful implementation of the FAVA maps was facilitated by the overall project design, which included a needs assessment and iterative technical advisory committee input and review. Ongoing programs to protect Florida's springsheds have led to development of larger-scale WofE-based vulnerability assessments. Additional applications of the maps include land-use planning

  9. The implementation of portfolio assessment by the educators on the mathematics learning process in senior high school

    Science.gov (United States)

    Lestariani, Ida; Sujadi, Imam; Pramudya, Ikrar

    2018-05-01

    Portfolio assessment can shows the development of the ability of learners in a period through the work so that can be seen progress monitored learning of each learner. The purpose of research to describe and know the implementation of portfolio assessment on the mathematics learning process with the Senior High school math teacher class X as the subject because of the importance of applying the assessment for the progress of learning outcomes of learners. This research includes descriptive qualitative research type. Techniques of data collecting is done by observation method, interview and documentation. Data collection then validated using triangulation technique that is observation technique, interview and documentation. Data analysis technique is done by data reduction, data presentation and conclusion. The results showed that the steps taken by teachers in applying portfolio assessment obtained focused on learning outcomes. Student learning outcomes include homework and daily tests. Based on the results of research can be concluded that the implementation of portfolio assessment is the form of learning results are scored. Teachers have not yet implemented other portfolio assessment techniques such as student work.

  10. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  11. IMPLEMENTATION OF HEALTH TECHNOLOGY ASSESSMENT WORK IN A HOSPITAL IN KAZAKHSTAN.

    Science.gov (United States)

    Kosherbayeva, Lyazzat; Hailey, David; Kurakbaev, Kural; Tsoy, Aleksey; Zhuzzhanov, Ormanbek; Donbay, Abilay; Kumar, Ainur; Nadyrov, Kamalzhan

    2016-01-01

    The aim of this study was to implement health technology assessment (HA) in the First General City Hospital in Astana, Kazakhstan. We organized trainings to familiarize hospital staff with the purpose and details of HTA. An HTA committee was established, with representation from hospital physicians and managers, and criteria for prioritization of health technologies determined. Clinical departments of the hospital were asked to prepare applications for new technologies for their services. The HTA committee reviewed five applications and selected a technology from one of these, on single incision laparoscopic surgery (SILS), for assessment. A short HTA report on SILS was prepared, covering its safety, clinical effectiveness, and cost effectiveness. The report was used to support a request to the Department of Health for additional funding to implement this technology within the hospital. This funding was approved and SILS was established in several hospital departments. This successful initial experience with HTA has paved the way for its routine use by the hospital for informing decisions on the procurement and use of new health technologies.

  12. Guidance for Large-scale Implementation of Alternate Wetting and Drying: A Biophysical Suitability Assessment

    Science.gov (United States)

    Sander, B. O.; Wassmann, R.; Nelson, A.; Palao, L.; Wollenberg, E.; Ishitani, M.

    2014-12-01

    The alternate wetting and drying (AWD) technology for rice production does not only save 15-30% of irrigation water, it also reduces methane emissions by up to 70%. AWD is defined by periodic drying and re-flooding of a rice field. Due to its high mitigation potential and its simplicity to execute this practice AWD has gained a lot of attention in recent years. The Climate and Clean Air Coalition (CCAC) has put AWD high on its agenda and funds a project to guide implementation of this technology in Vietnam, Bangladesh and Colombia. One crucial activity is a biophysical suitability assessment for AWD in the three countries. For this, we analyzed rainfall and soil data as well as potential evapotranspiration to assess if the water balance allows practicing AWD or if precipitation is too high for rice fields to fall dry. In my talk I will outline key factors for a successful large-scale implementation of AWD with a focus on the biophysical suitability assessment. The seasonal suitability maps that we generated highlight priority areas for AWD implementation and guide policy makers to informed decisions about meaningful investments in infrastructure and extension work.

  13. Nigeria; Publication of Financial Sector Assessment Program Documentation––Detailed Assessment of Implementation of IOSCO Objectives and Principles of Securities Regulation

    OpenAIRE

    International Monetary Fund

    2013-01-01

    An assessment of the level of implementation of the International Organization of Securities Commissions (IOSCO) Principles in Nigeria was conducted as part of the International Monetary Fund (IMF)-World Bank Financial Sector Assessment Program (FSAP). The ongoing global financial crisis has reinforced the need for assessors to make a judgment about supervisory practices and to determine whether they are sufficiently effective. The assessment methodology provides a set of assessment criteria ...

  14. An examination of cross-cultural systems implementing evidence-based assessment and intervention approaches

    Directory of Open Access Journals (Sweden)

    Murray Laura K

    2006-01-01

    Full Text Available Implementation of evidence-based assessment and intervention approaches for youth with behavioral and/or emotional problems is rising to recognition worldwide. Feasibility research is critical to examine what characteristics of systems allow for success or barriers to the implementation of evidence-based practices into real-world settings, especially when working cross-culturally. This paper briefly reviews the experience of 4 international sites to understand how the overall structure and specific site variables directed the implementation of the World Health Organization and the World Psychiatry Association project. Discussion includes a thematic summary of the successes and challenges experienced by the sites, and future directions of feasibility studies.

  15. Medical device risk management and its economic impact

    Directory of Open Access Journals (Sweden)

    Katerina Krsteva Jakimovska

    2013-10-01

    Full Text Available The importance of medical devices in everyday users/patients lives is imensse. This is the reason why emphasis must be put on safety during their use. Satisfactory safety level can be achived by implementation of quality and risk management standards. Medical device manufacturers must learn to deal with the potential risks by using theoretical and practical examples and measures in order to protect their users/patients and themselves from suffering huge losses arising from adverse events or recall of their products. The best moment for implementation of risk management methods and analysis begins from the device design and development through manufacturing, sales and distribution. These way medical device manufacturers will succseed in protecting their users/patients from serious adverse events and at the same time protect their brand and society status, while minimizing economic losses.

  16. Implementing Summative Assessment with a Formative Flavour: A Case Study in a Large Class

    Science.gov (United States)

    Broadbent, Jaclyn; Panadero, Ernesto; Boud, David

    2018-01-01

    Teaching a large class can present real challenges in design, management and standardisation of assessment practices. One of the main dilemmas for university teachers is how to implement effective formative assessment practices with accompanying high-quality feedback consistently over time with large classroom groups. This article reports on how…

  17. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    Science.gov (United States)

    Riggert, C.; Ziegler, M.; Schroeder, D.; Krautschneider, W. H.; Kohlstedt, H.

    2014-10-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit.

  18. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    International Nuclear Information System (INIS)

    Riggert, C; Ziegler, M; Kohlstedt, H; Schroeder, D; Krautschneider, W H

    2014-01-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit. (paper)

  19. Development and implementation of Strategic Environmental Assessment in Taiwan

    International Nuclear Information System (INIS)

    Liou, M.-L.; Yu, Y.-H.

    2004-01-01

    Taiwan is one of the few Asian countries to have officially adopted Strategic Environmental Assessment (SEA) as one important means towards the achievement of environmental conservation and sustainable development. Despite implementation almost a decade ago, SEA remains premature in its development. This paper analyzes the progress and characteristics of SEA in Taiwan and, through examination of its limited case studies, reveals the positive and apparent influence of SEA on policy making. This paper also identifies the barriers hindering SEA's advancement and concludes with recommendations on strategies to overcome these obstacles

  20. Implementation of Summon at KAUST

    KAUST Repository

    Buck, Stephen

    2017-03-09

    Web discovery services has evolved tremendously from the time of its introduction to present day. Their technology has enabled library users to obtain a variety of materials in different format and type faster and farther. Coupled with a myriad of features, users are ‘pampered’ with the options to email, download citations, full text articles, book chapters on different devices such as laptops, desktops and mobile devices (among others). In this session, the speaker will highlight KAUST library’s new discovery service (KORAL powered by Summon) launched in June 2016. Topics include the implementation project, its challenges and lessons learnt and the after-implementation initiatives.

  1. Implementation of Summon at KAUST

    KAUST Repository

    Buck, Stephen; Ramli, Rindra M.

    2017-01-01

    Web discovery services has evolved tremendously from the time of its introduction to present day. Their technology has enabled library users to obtain a variety of materials in different format and type faster and farther. Coupled with a myriad of features, users are ‘pampered’ with the options to email, download citations, full text articles, book chapters on different devices such as laptops, desktops and mobile devices (among others). In this session, the speaker will highlight KAUST library’s new discovery service (KORAL powered by Summon) launched in June 2016. Topics include the implementation project, its challenges and lessons learnt and the after-implementation initiatives.

  2. Introduction to the special issue: toward implementing physiological measures in clinical child and adolescent assessments.

    Science.gov (United States)

    De Los Reyes, Andres; Aldao, Amelia

    2015-01-01

    The National Institute of Mental Health recently launched the Research Domain Criteria (RDoC). The RDoC is an initiative to improve classification of mental health concerns by promoting research on the brain mechanisms underlying these concerns, with the ultimate goal of developing interventions that target these brain mechanisms. A key focus of RDoC involves opening new lines of research examining patients' responses on biological measures. The RDoC presents unique challenges to mental health professionals who work with children and adolescents. Indeed, mental health professionals rarely integrate biological measures into clinical assessments. Thus, RDoC's ability to improve patient care rests, in part, on the development of strategies for implementing biological measures within mental health assessments. Further, mental health professionals already carry out comprehensive assessments that frequently yield inconsistent findings. These inconsistencies have historically posed challenges to interpreting research findings as well as assessment outcomes in practice settings. In this introductory article, we review key issues that informed the development of a special issue of articles demonstrating methods for implementing low-cost measures of physiological functioning in clinical child and adolescent assessments. We also outline a conceptual framework, informed by theoretical work on using and interpreting multiple informants' clinical reports (De Los Reyes, Thomas, Goodman, & Kundey, 2013 ), to guide hypothesis testing when using physiological measures within clinical child and adolescent assessments. This special issue and the conceptual model described in this article may open up new lines of research testing paradigms for implementing clinically feasible physiological measures in clinical child and adolescent assessments.

  3. Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.

    Science.gov (United States)

    Quek, Desmond T; Narayanaswamy, Arun K; Tun, Tin A; Htoon, Hla M; Baskaran, Mani; Perera, Shamira A; Aung, Tin

    2012-08-03

    To compare two spectral domain optical coherence tomography (SD-OCT) devices for the identification of angle structures and the presence of angle closure. This was a prospective comparative study. Consecutive patients underwent gonioscopy and anterior segment imaging using two SD-OCT devices (iVue and Cirrus). Images were evaluated for the ability to detect angle structures such as Schwalbe's line (SL), trabecular meshwork (TM), Schlemm's canal (SC), and scleral spur (SS), and the presence of angle closure. Angle closure was defined as iris contact with the angle wall anterior to the SS on SD-OCT, and nonvisibility of the posterior TM on gonioscopy. Angle closure in an eye was defined as ≥two quadrants of closed angles. AC1 statistic was used to assess the agreement between devices. Of the 69 subjects studied (46.4% male, 84.1% Chinese, mean age 64.0 ± 10.5 years), 40 subjects (40 eyes, 58.0%) had angle closure on gonioscopy. The most identifiable structure on Cirrus SD-OCT was the SS (82.2%) and SL on iVue SD-OCT (74.5%). Angle closure was indeterminable in 14.5% and 50.7% of Cirrus and iVue scans (P gonioscopy was only fair (AC1 = 0.35 and 0.50 for Cirrus and iVue, respectively). It was more difficult to determine angle closure status with iVue compared with Cirrus SD-OCT. There was fair agreement between both devices with gonioscopy for identifying angle closure.

  4. Keep taking the tablets? Assessing the use of tablet devices in learning and teaching activities in the Further Education sector

    OpenAIRE

    Khristin Fabian; Donald MacLean

    2014-01-01

    This article summarises the methodology and outcomes of an interventionist/action research project to assess the benefits, and potential pitfalls, of the use of mobile devices in learning and teaching activities in a Further Education environment. A bank of 15 tablet devices were purchased and prepared for classroom use. Staff members were approached to scope potential activities and uses for the tablet devices. Three departments took part in the research activity: the Language School, Social...

  5. Measuring the food service environment: development and implementation of assessment tools.

    Science.gov (United States)

    Minaker, Leia M; Raine, Kim D; Cash, Sean B

    2009-01-01

    The food environment is increasingly being implicated in the obesity epidemic, though few reported measures of it exist. In order to assess the impact of the food environment on food intake, valid measures must be developed and tested. The current study describes the development of a food service environment assessment tool and its implementation in a community setting. A descriptive study with mixed qualitative and quantitative methods at a large, North American university campus was undertaken. Measures were developed on the basis of a conceptual model of nutrition environments. Measures of community nutrition environment were the number, type and hours of operation of each food service outlet on campus. Measures of consumer nutrition environment were food availability, food affordability, food promotion and nutrition information availability. Seventy-five food service outlets within the geographic boundaries were assessed. Assessment tools could be implemented in a reasonable amount of time and showed good face and content validity. The food environments were described and measures were grouped so that food service outlet types could be compared in terms of purchasing convenience, cost/value, healthy food promotion and health. Food service outlet types that scored higher in purchasing convenience and cost/value tended to score lower in healthy food promotion and health. This study adds evidence that food service outlet types that are convenient to consumers and supply high value (in terms of calories per dollar) tend to be less health-promoting. Results from this study also suggest the possibility of characterizing the food environment according to the type of food service outlet observed.

  6. Nuclear Regulatory Commission probabilistic risk assessment implementation program: A status report

    International Nuclear Information System (INIS)

    Rubin, M.P.; Caruso, M.A.

    1996-01-01

    The US Nuclear Regulatory Commission (NRC) is undertaking a number of activities intended to increase the consideration of risk significance in its decision processes and the effective use of risk-based technologies in its regulatory activities. Although the NRC is moving toward risk-informed regulation throughout its areas of responsibilities, this paper focuses primarily on those issues associated with reactor regulation. As the NRC completed significant milestones in its development of probabilistic risk assessment (PRA) methodology and gained considerable experience in the limited application of risk assessment to selected regulatory activities, it became evident that a much broader use of risk informed approaches offered advantages to both the NRC and the US commercial nuclear industry. This desire to enhance the use of risk assessment is driven by the clear belief that application of PRA methods will result in direct improvements in nuclear power plant operational safety from the perspective of both the regulator and the plant operator. The NRC believed that an overall policy on the use of PRA methods in nuclear regulatory activities should be established so that the many potential applications of PRA could be implemented in a consistent and predictable manner that would promote regulatory stability and efficiency. This paper describes the key activities that the NRC has undertaken to implement the initial stages of an integrated risk-informed regulatory framework

  7. The implementation of assessment model based on character building to improve students’ discipline and achievement

    Science.gov (United States)

    Rusijono; Khotimah, K.

    2018-01-01

    The purpose of this research was to investigate the effect of implementing the assessment model based on character building to improve discipline and student’s achievement. Assessment model based on character building includes three components, which are the behaviour of students, the efforts, and student’s achievement. This assessment model based on the character building is implemented in science philosophy and educational assessment courses, in Graduate Program of Educational Technology Department, Educational Faculty, Universitas Negeri Surabaya. This research used control group pre-test and post-test design. Data collection method used in this research were observation and test. The observation was used to collect the data about the disciplines of the student in the instructional process, while the test was used to collect the data about student’s achievement. Moreover, the study applied t-test to the analysis of data. The result of this research showed that assessment model based on character building improved discipline and student’s achievement.

  8. Mobile devices for community-based REDD+ monitoring: a case study for Central Vietnam.

    Science.gov (United States)

    Pratihast, Arun Kumar; Herold, Martin; Avitabile, Valerio; de Bruin, Sytze; Bartholomeus, Harm; Souza, Carlos M; Ribbe, Lars

    2012-12-20

    Monitoring tropical deforestation and forest degradation is one of the central elements for the Reduced Emissions from Deforestation and Forest Degradation in developing countries (REDD+) scheme. Current arrangements for monitoring are based on remote sensing and field measurements. Since monitoring is the periodic process of assessing forest stands properties with respect to reference data, adopting the current REDD+ requirements for implementing monitoring at national levels is a challenging task. Recently, the advancement in Information and Communications Technologies (ICT) and mobile devices has enabled local communities to monitor their forest in a basic resource setting such as no or slow internet connection link, limited power supply, etc. Despite the potential, the use of mobile device system for community based monitoring (CBM) is still exceptional and faces implementation challenges. This paper presents an integrated data collection system based on mobile devices that streamlines the community-based forest monitoring data collection, transmission and visualization process. This paper also assesses the accuracy and reliability of CBM data and proposes a way to fit them into national REDD+ Monitoring, Reporting and Verification (MRV) scheme. The system performance is evaluated at Tra Bui commune, Quang Nam province, Central Vietnam, where forest carbon and change activities were tracked. The results show that the local community is able to provide data with accuracy comparable to expert measurements (index of agreement greater than 0.88), but against lower costs. Furthermore, the results confirm that communities are more effective to monitor small scale forest degradation due to subsistence fuel wood collection and selective logging, than high resolution remote sensing SPOT imagery.

  9. Environmental assessment of wood burning in independent heating devices

    International Nuclear Information System (INIS)

    Rogaume, C.; Rogaume, Y.; Zoulalian, A.; Trouve, G.

    2009-01-01

    An environmental assessment has been achieved on two domestic wood-heating devices, a closed fireplace and an open fireplace which represent 80% of the sale market of wood small-scale combustion units and around 65% of the use of wood-energy in France. Not only deals this study with the atmospheric polluting emissions produced in the exhaust stack, but also with the indoor air quality. Therefore, different pollutants were measured at the emission stage and as indoor air concentrations: carbon monoxide (CO), carbon dioxide (CO 2 ), volatile organic compounds (VOC), methane (CH 4 ), nitrogen oxides (NO X ), particulate matter with different sizes (PM 10 to PM 0.1 ), polycyclic aromatic hydrocarbons (PAH) and dioxines and furans. The results concerning indoor air were compared to measurements that showed the influence of residential heating devices. without exhaust duct like an oil stove or a gas stove (space heater) on indoor air quality. Some combustion emission experiments achieved in normal conditions showed that the combustion in open fireplace pollutes more than the combustion in closed fire-place: around 10 times more of PM 2.5 (mass concentration), more than 4 times of total VOC, 1.5 times more of dioxines and furans. On the other hand, the opposite trend was shown for PAH emissions (between 2 and 3 times less depending on the regulations considered). The comparison of the impact of different heating appliances on indoor air quality shows that the rate of CO is the same for all the devices except for the open fireplace which is higher. The CO 2 rate is 10 times higher for the oil stove and 8 times higher for the gas stove than for the fireplaces, which is due to the lack of exhaust duct. The concentration of PM 2.5 is 16 times higher for the open fireplace, 1.6 times higher for the oil stove and 4.4 times higher for the gas stove than the closed fireplace. The percentage of the number distribution of nano-particles, that represents an enhanced health risk

  10. Independent assessment to continue improvement: Implementing statistical process control at the Hanford Site

    International Nuclear Information System (INIS)

    Hu, T.A.; Lo, J.C.

    1994-11-01

    A Quality Assurance independent assessment has brought about continued improvement in the PUREX Plant surveillance program at the Department of Energy's Hanford Site. After the independent assessment, Quality Assurance personnel were closely involved in improving the surveillance program, specifically regarding storage tank monitoring. The independent assessment activities included reviewing procedures, analyzing surveillance data, conducting personnel interviews, and communicating with management. Process improvement efforts included: (1) designing data collection methods; (2) gaining concurrence between engineering and management, (3) revising procedures; and (4) interfacing with shift surveillance crews. Through this process, Statistical Process Control (SPC) was successfully implemented and surveillance management was improved. The independent assessment identified several deficiencies within the surveillance system. These deficiencies can be grouped into two areas: (1) data recording and analysis and (2) handling off-normal conditions. By using several independent assessment techniques, Quality Assurance was able to point out program weakness to senior management and present suggestions for improvements. SPC charting, as implemented by Quality Assurance, is an excellent tool for diagnosing the process, improving communication between the team members, and providing a scientific database for management decisions. In addition, the surveillance procedure was substantially revised. The goals of this revision were to (1) strengthen the role of surveillance management, engineering and operators and (2) emphasize the importance of teamwork for each individual who performs a task. In this instance we believe that the value independent assessment adds to the system is the continuous improvement activities that follow the independent assessment. Excellence in teamwork between the independent assessment organization and the auditee is the key to continuing improvement

  11. Framework and operational procedure for implementing Strategic Environmental Assessment in China

    International Nuclear Information System (INIS)

    Bao Cunkuan; Lu Yongsen; Shang Jincheng

    2004-01-01

    Over the last 20 years, Environmental Impact Assessment (EIA) has been implemented and become an important instrument for decision-making in development projects in China. The Environmental Impact Assessment Law of the P.R. China was promulgated on 28 October 2002 and will be put into effect on 1 September of 2003. The law provides that Strategic Environmental Assessment (SEA) is required in regional and sector plans and programs. This paper introduces the research achievements and practice of SEA in China, discusses the relationship of SEA and 'integrating of environment and development in decision-making (IEDD)', and relevant political and legal basis of SEA. The framework and operational procedures of SEA administration and enforcement are presented. Nine cases are analyzed and some proposals are given

  12. Design and implementation of a wireless (Bluetooth) four channel bio-instrumentation amplifier and digital data acquisition device with user-selectable gain, frequency, and driven reference.

    Science.gov (United States)

    Cosmanescu, Alin; Miller, Benjamin; Magno, Terence; Ahmed, Assad; Kremenic, Ian

    2006-01-01

    A portable, multi-purpose Bio-instrumentation Amplifier and Data AcQuisition device (BADAQ) capable of measuring and transmitting EMG and EKG signals wirelessly via Bluetooth is designed and implemented. Common topologies for instrumentation amplifiers and filters are used and realized with commercially available, low-voltage, high precision operational amplifiers. An 8-bit PIC microcontroller performs 10-bit analog-to-digital conversion of the amplified and filtered signals and controls a Bluetooth transceiver capable of wirelessly transmitting the data to any Bluetooth enabled device. Electrical isolation between patient/subject, circuitry, and ancillary equipment is achieved by optocoupling components. The design focuses on simplicity, portability, and affordability.

  13. Design, development, and evaluation of a novel retraction device for gallbladder extraction during laparoscopic cholecystectomy.

    Science.gov (United States)

    Judge, Joshua M; Stukenborg, George J; Johnston, William F; Guilford, William H; Slingluff, Craig L; Hallowell, Peter T

    2014-02-01

    A source of frustration during laparoscopic cholecystectomy involves extraction of the gallbladder through port sites smaller than the gallbladder itself. We describe the development and testing of a novel device for the safe, minimal enlargement of laparoscopic port sites to extract large, stone-filled gallbladders from the abdomen. The study device consists of a handle with a retraction tongue to shield the specimen and a guide for a scalpel to incise the fascia within the incision. Patients enrolled underwent laparoscopic cholecystectomy. Gallbladder extraction was attempted. If standard measures failed, the device was implemented. Extraction time and device utility scores were recorded for each patient. Patients returned 3-4 weeks postoperatively for assessment of pain level, cosmetic effect, and presence of infectious complications. Twenty (51 %) of 39 patients required the device. Average extraction time for the first eight patients was 120 s. After interim analysis, an improved device was used in 12 patients and average extraction time was 24 s. There were no adverse events. Postoperative pain ratings and incision cosmesis were comparable between patients with and without use of the device. The study device enables safe and rapid extraction of impacted gallbladders through the abdominal wall.

  14. An assessment of implementation and evaluation phases of strategic plans in Iranian hospitals.

    Science.gov (United States)

    Sadeghifar, Jamil; Tofighi, Shahram; Roshani, Mohamad; Toulideh, Zahra; Mohsenpour, Seyedramezan; Jafari, Mehdi

    2017-01-01

    To assess the implementation and evaluation phases of strategic plans in selected hospitals. We conducted a cross-sectional study of implementation and evaluation of strategic plan in 24 hospitals in 2015, using a questionnaire which consisted of two separate sections for strategic implementation and strategic evaluation. Data were analyzed with SPSS version 18. Nearly one-third of hospitals claimed that they allocate their budget based on priorities and strategic goals. However, it turned out that although goals had been set, no formal announcements had been made. Most of the hospitals stated that they used measures when evaluating the plan. For hospital staff, clarifying the hospital's priorities was the most important advantage of a strategic plan. There is no clear definition for strategic management in Iranian hospitals, which results in chaotic implementation and control of strategic planning.

  15. CIRSE Vascular Closure Device Registry

    NARCIS (Netherlands)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. The CIRSE registry of closure devices

  16. Development and evaluation of a novel smart device-based application for burn assessment and management.

    Science.gov (United States)

    Godwin, Zachary; Tan, James; Bockhold, Jennifer; Ma, Jason; Tran, Nam K

    2015-06-01

    We have developed a novel software application that provides a simple and interactive Lund-Browder diagram for automatic calculation of total body surface area (TBSA) burned, fluid formula recommendations, and serial wound photography on a smart device platform. The software was developed for the iPad (Apple, Cupertino, CA) smart device platforms. Ten burns ranging from 5 to 95% TBSA were computer generated on a patient care simulator using Adobe Photoshop CS6 (Adobe, San Jose, CA). Burn clinicians calculated the TBSA first using a paper-based Lund-Browder diagram. Following a one-week "washout period", the same clinicians calculated TBSA using the smart device application. Simulated burns were presented in a random fashion and clinicians were timed. Percent TBSA burned calculated by Peregrine vs. the paper-based Lund-Browder were similar (29.53 [25.57] vs. 28.99 [25.01], p=0.22, n=7). On average, Peregrine allowed users to calculate burn size significantly faster than the paper form (58.18 [31.46] vs. 90.22 [60.60]s, p<0.001, n=7). The smart device application also provided 5 megapixel photography capabilities, and acute burn resuscitation fluid calculator. We developed an innovative smart device application that enables accurate and rapid burn size assessment to be cost-effective and widely accessible. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  17. Self-assessment as an approach to improvement of efficient implementation of Ukrainian NPP operational experience

    International Nuclear Information System (INIS)

    Pecheritsya, L.M.; Lyigots'kij, O.Yi.; Pecheritsya, O.V.; Tarasenko, V.M.

    2012-01-01

    the paper contains a brief description of the procedure for implementation of operational experience, focuses on the role of self -assessment in efficient use of operational experience, presents a review of international and national practices of self-assessment and review of the main features, issues and ways to improve self-assessment of efficient use of operational experience in Ukraine

  18. Considerations of device and operational flexibility in FER

    International Nuclear Information System (INIS)

    Sugihara, Masayoshi; Miki, Nobuharu; Nishio, Satoshi; Yamada, Masao; Yamamoto, Shin

    1988-01-01

    Expected physics uncertainties in DT burning plasma of FER, which may not be removed completely at the start of construction or DT operation, are reviewed. Several possible device and operational flexibility scenarios to cope with these uncertainties are considered. They are (1) Plasma size enlargement scenario, (2) Plasma shape flexibility scenario, (3) Heating/Current drive/Control system flexibility scenario, (4) Impurity control system flexibility scenario and (5) Advanced operation scenario. Feasibility of these flexibility scenarios are examined and shown to be practicable. However, careful assessment of the physics data base is necessary at the start of construction and DT operation to proceed to actually implement these flexibilities in FER. (author)

  19. Mobile devices a practical guide for librarians

    CERN Document Server

    Rawlins, Ben

    2014-01-01

    As more users expect to use their mobile devices, librarians will want and need to develop the necessary skills to reach this growing user base. Mobile Devices: A Practical Guide for Librarians will aid libraries and librarians as they go through the process of planning, developing, implementing, marketing, and evaluating mobile services.

  20. Assessing the potential roles of silicon and germanium phthalocyanines in planar heterojunction organic photovoltaic devices and how pentafluoro phenoxylation can enhance π-π interactions and device performance.

    Science.gov (United States)

    Lessard, Benoît H; White, Robin T; Al-Amar, Mohammad; Plint, Trevor; Castrucci, Jeffrey S; Josey, David S; Lu, Zheng-Hong; Bender, Timothy P

    2015-03-11

    In this study, we have assessed the potential application of dichloro silicon phthalocyanine (Cl2-SiPc) and dichloro germanium phthalocyanine (Cl2-GePc) in modern planar heterojunction organic photovoltaic (PHJ OPV) devices. We have determined that Cl2-SiPc can act as an electron donating material when paired with C60 and that Cl2-SiPc or Cl2-GePc can also act as an electron acceptor material when paired with pentacene. These two materials enabled the harvesting of triplet energy resulting from the singlet fission process in pentacene. However, contributions to the generation of photocurrent were observed for Cl2-SiPc with no evidence of photocurrent contribution from Cl2-GePc. The result of our initial assessment established the potential for the application of SiPc and GePc in PHJ OPV devices. Thereafter, bis(pentafluoro phenoxy) silicon phthalocyanine (F10-SiPc) and bis(pentafluoro phenoxy) germanium phthalocyanine (F10-GePc) were synthesized and characterized. During thermal processing, it was discovered that F10-SiPc and F10-GePc underwent a reaction forming small amounts of difluoro SiPc (F2-SiPc) and difluoro GePc (F2-GePc). This undesirable reaction could be circumvented for F10-SiPc but not for F10-GePc. Using single crystal X-ray diffraction, it was determined that F10-SiPc has significantly enhanced π-π interactions compared with that of Cl2-SiPc, which had little to none. Unoptimized PHJ OPV devices based on F10-SiPc were fabricated and directly compared to those constructed from Cl2-SiPc, and in all cases, PHJ OPV devices based on F10-SiPc had significantly improved device characteristics compared to Cl2-SiPc.

  1. Bone status in rheumatoid arthritis assessed at peripheral sites by three different quantitative ultrasound devices

    DEFF Research Database (Denmark)

    Madsen, O R; Suetta, C; Egsmose, C

    2004-01-01

    sites in 27 women with RA (mean disease duration 15 years) and in 36 healthy women matched for age, height and weight. Speed of sound (SOS, m/s), broadband ultrasound attenuation (BUA, dB/MHz) and stiffness of the calcaneus were assessed by a Lunar Achilles device. Amplitude-dependent SOS (Ad-SOS, m...

  2. Assessment of a prototype for the Systemization of Nursing Care on a mobile device

    Directory of Open Access Journals (Sweden)

    Laura Cristhiane Mendonça Rezende

    2016-01-01

    Full Text Available Abstract Objectives: assess a prototype for use on mobile devices that permits registering data for the Systemization of Nursing Care at a Neonatal Intensive Care Unit. Method: an exploratory and descriptive study was undertaken, characterized as an applied methodological research, developed at a teaching hospital. Results: the mobile technology the nurses at the Neonatal Intensive Care Unit use was positive, although some reported they faced difficulties to manage it, while others with experience in using mobile devices did not face problems to use it. The application has the functions needed for the Systematization of Nursing Care at the unit, but changes were suggested in the interface of the screens, some data collection terms and parameters the application offers. The main contributions of the software were: agility in the development and documentation of the systemization, freedom to move, standardization of infant assessment, optimization of time to develop bureaucratic activities, possibilities to recover information and reduction of physical space the registers occupy. Conclusion: prototype software for the Systemization of Nursing Care with mobile technology permits flexibility for the nurses to register their activities, as the data can be collected at the bedside.

  3. Assessment of a prototype for the Systemization of Nursing Care on a mobile device.

    Science.gov (United States)

    Rezende, Laura Cristhiane Mendonça; Santos, Sérgio Ribeiro Dos; Medeiros, Ana Lúcia

    2016-01-01

    assess a prototype for use on mobile devices that permits registering data for the Systemization of Nursing Care at a Neonatal Intensive Care Unit. an exploratory and descriptive study was undertaken, characterized as an applied methodological research, developed at a teaching hospital. the mobile technology the nurses at the Neonatal Intensive Care Unit use was positive, although some reported they faced difficulties to manage it, while others with experience in using mobile devices did not face problems to use it. The application has the functions needed for the Systematization of Nursing Care at the unit, but changes were suggested in the interface of the screens, some data collection terms and parameters the application offers. The main contributions of the software were: agility in the development and documentation of the systemization, freedom to move, standardization of infant assessment, optimization of time to develop bureaucratic activities, possibilities to recover information and reduction of physical space the registers occupy. prototype software for the Systemization of Nursing Care with mobile technology permits flexibility for the nurses to register their activities, as the data can be collected at the bedside.

  4. 76 FR 44489 - Medical Devices; Neurological Devices; Classification of Repetitive Transcranial Magnetic...

    Science.gov (United States)

    2011-07-26

    ... is an external device that delivers transcranial repetitive pulsed magnetic fields of sufficient... premarket notification, prior to marketing the device, which contains information about the rTMS system they... significant effect on the human environment. Thus, neither an environmental assessment nor an environmental...

  5. Keep Taking the Tablets? Assessing the Use of Tablet Devices in Learning and Teaching Activities in the Further Education Sector

    Science.gov (United States)

    Fabian, Khristin; MacLean, Donald

    2014-01-01

    This article summarises the methodology and outcomes of an interventionist/action research project to assess the benefits, and potential pitfalls, of the use of mobile devices in learning and teaching activities in a Further Education environment. A bank of 15 tablet devices were purchased and prepared for classroom use. Staff members were…

  6. Portable Wireless Device Threat Assessment for Aircraft Navigation Radios

    Science.gov (United States)

    Nguyen, Truong X.; Koppen, Sandra V.; Ely, Jay J.; Williams, Reuben A.; Smith, Laura J.; Salud, Maria Theresa P.

    2004-01-01

    This paper addresses the concern for Wireless Local Area Network devices and two-way radios to cause electromagnetic interference to aircraft navigation radio systems. Spurious radiated emissions from various IEEE 802.11a, 802.11b, and Bluetooth devices are characterized using reverberation chambers. The results are compared with baseline emissions from standard laptop computer and personal digital assistants (PDAs) that are currently allowed for use on aircraft. The results indicate that the WLAN devices tested are not more of a threat to aircraft navigation radios than standard laptop computers and PDAs in most aircraft bands. In addition, spurious radiated emission data from seven pairs of two-way radios are provided. These two-way radios emit at much higher levels in the bands considered. A description of the measurement process, device modes of operation and the measurement results are reported.

  7. Verification, Validation and Credibility Assessment of a Computational Model of the Advanced Resistive Exercise Device (ARED)

    Science.gov (United States)

    Werner, C. R.; Humphreys, B. T.; Mulugeta, L.

    2014-01-01

    The Advanced Resistive Exercise Device (ARED) is the resistive exercise device used by astronauts on the International Space Station (ISS) to mitigate bone loss and muscle atrophy due to extended exposure to microgravity (micro g). The Digital Astronaut Project (DAP) has developed a multi-body dynamics model of biomechanics models for use in spaceflight exercise physiology research and operations. In an effort to advance model maturity and credibility of the ARED model, the DAP performed verification, validation and credibility (VV and C) assessment of the analyses of the model in accordance to NASA-STD-7009 'Standards for Models and Simulations'.

  8. Implementing Management Systems-Based Assessments

    International Nuclear Information System (INIS)

    Campisi, John A.; Reese, Robert T.

    1999-01-01

    A management system approach for evaluating environment, safety, health, and quality is in use at Sandia National Laboratories (SNL). Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000. As a multi-program national laboratory, SNL has many diverse operations including research, engineering development and applications, production, and central services supporting all activities and operations. Basic research examples include fusion power generation, nuclear reactor experiments, and investigation of combustion processes. Engineering development examples are design, testing, and prototype developments of micro-mechanical systems for safe'arding computer systems, air bags for automobiles, satellite systems, design of transportation systems for nuclear materials, and systems for use in medical applications such as diagnostics and surgery. Production operations include manufacture of instrumented detection devices, radioisotopes, and replacement parts for previously produced engineered systems. Support services include facilities engineering, construction, and site management, site security, packaging and transportation of hazardous materials wastes, ES ampersand H functional programs to establish requirements and guidance to comply with federal, state, local, and contractual requirements and work safety. In this diverse environment, unlike more traditional single function business units, an integrated consistent management system is not typical. Instead, each type of diverse activity has its own management system designed and distributed around the operations, personnel, customers, and facilities (e.g., hazards involved, security, regulatory requirements, and locations). Laboratory managers are not likely to have experience in the more traditional hierarchical or command and control structures and thus do not share oversight expectations found in

  9. Implementing Management Systems-Based Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Campisi, John A.; Reese, Robert T.

    1999-05-03

    A management system approach for evaluating environment, safety, health, and quality is in use at Sandia National Laboratories (SNL). Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000. As a multi-program national laboratory, SNL has many diverse operations including research, engineering development and applications, production, and central services supporting all activities and operations. Basic research examples include fusion power generation, nuclear reactor experiments, and investigation of combustion processes. Engineering development examples are design, testing, and prototype developments of micro-mechanical systems for safe'~arding computer systems, air bags for automobiles, satellite systems, design of transportation systems for nuclear materials, and systems for use in medical applications such as diagnostics and surgery. Production operations include manufacture of instrumented detection devices, radioisotopes, and replacement parts for previously produced engineered systems. Support services include facilities engineering, construction, and site management, site security, packaging and transportation of hazardous materials wastes, ES&H functional programs to establish requirements and guidance to comply with federal, state, local, and contractual requirements and work safety. In this diverse environment, unlike more traditional single function business units, an integrated consistent management system is not typical. Instead, each type of diverse activity has its own management system designed and distributed around the operations, personnel, customers, and facilities (e.g., hazards involved, security, regulatory requirements, and locations). Laboratory managers are not likely to have experience in the more traditional hierarchical or command and control structures and thus do not share oversight expectations found in

  10. Early decision-analytic modeling - a case study on vascular closure devices.

    Science.gov (United States)

    Brandes, Alina; Sinner, Moritz F; Kääb, Stefan; Rogowski, Wolf H

    2015-10-27

    As economic considerations become more important in healthcare reimbursement, decisions about the further development of medical innovations need to take into account not only medical need and potential clinical effectiveness, but also cost-effectiveness. Already early in the innovation process economic evaluations can support decisions on development in specific indications or patient groups by anticipating future reimbursement and implementation decisions. One potential concept for early assessment is value-based pricing. The objective is to assess the feasibility of value-based pricing and product design for a hypothetical vascular closure device in the pre-clinical stage which aims at decreasing bleeding events. A deterministic decision-analytic model was developed to estimate the cost-effectiveness of established vascular closure devices from the perspective of the Statutory Health Insurance system. To identify early benchmarks for pricing and product design, three strategies of determining the product's value are explored: 1) savings from complications avoided by the new device; 2) valuation of the avoided complications based on an assumed willingness-to-pay-threshold (the efficiency frontier approach); 3) value associated with modifying the care pathways within which the device would be applied. Use of established vascular closure devices is dominated by manual compression. The hypothetical vascular closure device reduces overall complication rates at higher costs than manual compression. Maximum cost savings of only about €4 per catheterization could be realized by applying the hypothetical device. Extrapolation of an efficiency frontier is only possible for one subgroup where vascular closure devices are not a dominated strategy. Modifying care in terms of same-day discharge of patients treated with vascular closure devices could result in cost savings of €400-600 per catheterization. It was partially feasible to calculate value-based prices for the

  11. Students’ Perception toward the Implementation of Peer-Assessment in Writing; Before and After Revision

    Directory of Open Access Journals (Sweden)

    Husni Mubarok

    2017-10-01

    Full Text Available This study was aimed at elaborating students’ perception toward the implementation of peer assessment in writing class either before or after revision. Writing becomes one of skills which should be mastered by students in order to get higher level of literacy. Writing is a productive skill which asks students to arrange words and organize them into good writing which could be understood by readers. The success of writing is determined by the writing process itself starting from planning, first draft writing, revising, and editing. One of the strategies used in teaching writing is by implementing peer assessment. Peer assessment strategy becomes one of important parts in the process of writing because there will be feedback or suggestion from peers in doing a review. The number of the subject of this research was students in second semester of the English Education Department of UNISNU Jepara. This research was conducted on even semester. The total number of the students, which became respondents, was 37 students of English Education Department. The research design used was qualitative research which measured students’ perceptions of the implementation of peer assessment in writing: before and after revision. The result showed that before revision, students had negative perception toward their own writing. After revision, they had positive perceptions toward peer assessment strategy. Those included usefulness and meaningfulness, nature of feedback, reality of feedback, precision, validity, fairness, and personal goal-setting. Besides that, the score after revision (7.9 was higher than the score before revision (6.62. It meant that the result showed the increasing of students’ score after revision.

  12. EMERGENCE OF "DRIVERS" FOR THE IMPLEMENTATION OF HEALTH TECHNOLOGY ASSESSMENT.

    Science.gov (United States)

    Castro Jaramillo, Hector Eduardo; Moreno-Mattar, Ornella; Osorio-Cuevas, Diana

    2016-01-01

    Health technology assessment (HTA) examines the consequences of the application of health technologies and is aimed at better informing decision-makers. Over the past 30 years, different countries have implemented HTA organizations. Colombia established by law its own HTA agency (IETS) in 2011 which started operations in November 2012. The aim of this study was to assess the feasibility of conducting and using HTA to inform decision-making in this context. Through a qualitative approach, ten "drivers" emerged with the ability to help or hinder HTA development in this context: availability and quality of data, implementation strategy, cultural aspects, local capacity, financial support, policy/political support, globalization, stakeholder pressure, health system context, and usefulness perception. Semi-structured interviews were conducted with key HTA researchers, after following rigorous transcription, and thematic content analysis, those aspects that may be barriers or facilitator for HTA development and use in Colombia were identified. Although HTA has become a tool to inform decision-making around the world, its use may vary according to setting. Determining those aspects which may enable or interfere with HTA development and use in Colombia may be useful for other countries when considering the establishment of HTA systems. The conceptual transferability of concepts like "drivers" with caveats may be of interest for similar settings trying to incorporate HTA processes and institutions into systematic decision-making.

  13. Implementation of a three degree of freedom, motor/brake hybrid force output device for virtual environment control tasks

    Science.gov (United States)

    Russo, Massimo; Tadros, Alfred; Flowers, Woodie; Zeltzer, David

    1991-01-01

    The advent of high resolution, physical model based computer graphics has left a gap in the design of input/output technology appropriate for interacting with such complex virtual world models. Since virtual worlds consist of physical models, it is appropriate to output the inherent force information necessary for the simulation to the user. The detailed design, construction, and control of a three degree freedom force output joystick will be presented. A novel kinematic design allows all three axes to be uncoupled, so that the system inertia matrix is diagonal. The two planar axes are actuated through an offset gimbal, and the third through a sleeved cable. To compensate for friction and inertia effects, this transmission is controlled by a force feedforward and a closed force feedback proportional loop. Workspace volume is a cone of 512 cubic inches, and the device bandwidth is maximized at 60 Hz for the two planar and 30 Hz for the third axis. Each axis is controlled by a motor/proportional magnetic particle brake combination fixed to the base. The innovative use of motors and brakes allows objects with high resistive torque requirements to be simulated without the stability and related safety issues involved with high torque, energy storing motors alone. Position, velocity, and applied endpoint force are sensed directly. Different control strategies are discussed and implemented, with an emphasis on how virtual environment force information, generated by the MIT Media Lab Computer Graphics and Animation Group BOLIO system, is transmitted to the device controller. The design constraints for a kinesthetic force feedback device can be summarized as: How can the symbiosis between the sense of presence in the virtual environment be maximized without compromising the interaction task under the constraints of the mechanical device limitations? Research in this field will yield insights to the optimal human sensory feedback mix for a wide spectrum of control and

  14. Design of a SIP device cooperation system on OSGi service platforms

    Science.gov (United States)

    Takayama, Youji; Koita, Takahiro; Sato, Kenya

    2007-12-01

    Home networks feature such various technologies as protocols, specifications, and middleware, including HTTP, UPnP, and Jini. A service platform is required to handle such technologies to enable them to cooperate with different devices. The OSGi service platform, which meets the requirements based on service-oriented architecture, is designed and standardized by OSGi Alliance and consists of two parts: one OSGi Framework and bundles. On the OSGi service platform, APIs are defined as services that can handle these technologies and are implemented in the bundle. By using the OSGi Framework with bundles, various technologies can cooperate with each other. On the other hand, in IP networks, Session Initiation Protocol (SIP) is often used in device cooperation services to resolve an IP address, control a session between two or more devices, and easily exchange the statuses of devices. However, since many existing devices do not correspond to SIP, it cannot be used for device cooperation services. A device that does not correspond to SIP is called an unSIP device. This paper proposes and implements a prototype system that enables unSIP devices to correspond to SIP. For unSIP devices, the proposed system provides device cooperation services with SIP.

  15. To Assess Prerequisites Before an Implementation Strategy in an Orthopaedic Department in Sweden.

    Science.gov (United States)

    Bahtsevani, Christel; Idvall, Ewa

    2016-01-01

    Promoting Action on Research Implementation in Health Services (PARiHS) asserts that the success of knowledge implementation relates to multiple factors in a complex and dynamic way, and therefore the effects of implementation strategies vary by method and context. An instrument based on the PARiHS framework was developed to help assess critical factors influencing implementation strategies so that strategies can be tailored to promote implementation.The purpose of this study was to use the Evaluation Before Implementation Questionnaire (EBIQ), to describe staff perceptions in one orthopaedic department, and to investigate differences between wards.Staff members in four different wards at one orthopaedic department at a university hospital in Sweden were invited to complete a questionnaire related to planning for the implementation of a clinical practice guideline. The 23 items in the EBIQ were expected to capture staff perceptions about the evidence, context, and facilitation factors that influence the implementation process. Descriptive statistics and differences between wards were analyzed. Although the overall response rate was low (n = 49), two of the four wards accounted for most of the completed questionnaires (n = 25 and n = 12, respectively), enabling a comparison of these wards. We found significant differences between respondents' perceptions at the two wards in six items regarding context and facilitation in terms of receptiveness to change, forms of leadership, and evaluation and presence of feedback and facilitators.The EBIQ instrument requires further testing, but there appears to be initial support for pre-implementation use of the EBIQ as a means to enhance planning for implementation.

  16. Bluetooth API Implementation into Android

    Directory of Open Access Journals (Sweden)

    Konev Sergey

    2017-01-01

    Full Text Available Bluetooth is a popular method of communication between devices. Many smartphones today have the capability to communicate using Bluetooth. Android developers sometimes need to use Bluetooth in their projects. Android OS provides a powerful API for Bluetooth that allows to simplify scanning the environment for devices, pairing and connecting, data transfer between devices and more. However, utilizing the Bluetooth API can be difficult for first-time users. The objective of this article is to demonstrate the key points of implementing Bluetooth API in the Android application.

  17. Validity and reliability of simple measurement device to assess the velocity of the barbell during squats.

    Science.gov (United States)

    Lorenzetti, Silvio; Lamparter, Thomas; Lüthy, Fabian

    2017-12-06

    The velocity of a barbell can provide important insights on the performance of athletes during strength training. The aim of this work was to assess the validity and reliably of four simple measurement devices that were compared to 3D motion capture measurements during squatting. Nine participants were assessed when performing 2 × 5 traditional squats with a weight of 70% of the 1 repetition maximum and ballistic squats with a weight of 25 kg. Simultaneously, data was recorded from three linear position transducers (T-FORCE, Tendo Power and GymAware), an accelerometer based system (Myotest) and a 3D motion capture system (Vicon) as the Gold Standard. Correlations between the simple measurement devices and 3D motion capture of the mean and the maximal velocity of the barbell, as well as the time to maximal velocity, were calculated. The correlations during traditional squats were significant and very high (r = 0.932, 0.990, p squats and was less accurate. All the linear position transducers were able to assess squat performance, particularly during traditional squats and especially in terms of mean velocity and time to maximal velocity.

  18. Identification and assessment of site treatment plan implementation opportunities for emerging technologies

    International Nuclear Information System (INIS)

    Bernard, E.A.

    1995-01-01

    The Department of Energy (DOE), in response to the 1992 Federal Facility Compliance Act, has prepared Site Treatment Plans (STP) for the approximately 2,000 waste streams identified within its mixed waste inventory Concurrently, emerging mixed waste treatment technologies are in final development. This paper defines a three-phase process to identify and assess implementation opportunities for these emerging technologies within the STP. It highlights the first phase, functional matching of expected treatment capabilities with proposed treatment requirements. Matches are based on treatment type, regulated contaminant and waste matrix type, for both capabilities and requirements. Results identify specific waste streams and volumes that could be treated by each emerging technology. A study for Plasma Hearth Process, Delphi DETOX sm , Supercritical Water Oxidation and Vitrification shows that about 200,000 ml of DOE's mixed waste inventory can potentially be treated by one or more of these emerging technologies. Actual implementations are small fractions of the treatable inventory. Differences between potential and actual implementations must be minimized to accrue optimum benefit from implementation of emerging or alternative treatment technologies. Functional matching is the first phase in identifying and quantifying benefits, addressing technology system and treatment issues, and providing, in part, the basis for STP implementation decisions. DOE, through EM's Office of Technology Development, has funded this work

  19. NIMROD simulations and physics assessment of possible designs for a next generation Steady Inductive Helicity Injection HIT device

    Science.gov (United States)

    Penna, James; Morgan, Kyle; Grubb, Isaac; Jarboe, Thomas

    2017-10-01

    The Helicity Injected Torus - Steady Inductive 3 (HIT-SI3) experiment forms and maintains spheromaks via Steady Inductive Helicity Injection (SIHI) using discrete injectors that inject magnetic helicity via a non-axisymmetric perturbation and drive toroidally symmetric current. Newer designs for larger SIHI-driven spheromaks incorporate a set of injectors connected to a single external manifold to allow more freedom for the toroidal structure of the applied perturbation. Simulations have been carried out using the NIMROD code to assess the effectiveness of various imposed mode structures and injector schema in driving current via Imposed Dynamo Current Drive (IDCD). The results are presented here for varying flux conserver shapes on a device approximately 1.5 times larger than the current HIT-SI3 experiment. The imposed mode structures and spectra of simulated spheromaks are analyzed in order to examine magnetic structure and stability and determine an optimal regime for IDCD sustainment in a large device. The development of scaling laws for manifold operation is also presented, and simulation results are analyzed and assessed as part of the development path for the large scale device.

  20. Safety assessment to support NUE fuel full core implementation in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Fan, H.Z.; Laurie, T.; Siddiqi, A.; Li, Z.P.; Rouben, D.; Zhu, W.; Lau, V.; Cottrell, C.M. [CANDU Energy Inc., Mississauga, Ontario (Canada)

    2013-07-01

    The Natural Uranium Equivalent (NUE) fuel contains a combination of recycled uranium and depleted uranium, in such a manner that the resulting mixture is similar to the natural uranium currently used in CANDU® reactors. Based on successful preliminary results of 24 bundles of NUE fuel demonstration irradiation in Qinshan CANDU 6 Unit 1, the NUE full core implementation program has been developed in cooperation with the Third Qinshan Nuclear Power Company and Candu Energy Inc, which has recently received Chinese government policy and funding support from their National-Level Energy Innovation program. This paper presents the safety assessment results to technically support NUE fuel full core implementation in CANDU reactors. (author)

  1. Design and implementation of a device for measuring radiation energy of an electron accelerator

    International Nuclear Information System (INIS)

    Salhi, Heythem; Selmi, Samir

    2010-01-01

    Our work is part of a graduation project at the School of Technology and Computing, to obtain a master's degree in electrical engineering specialty industrial computer. Throughout the four-month internship at the National Center for Nuclear Science and Technology (CNSTN), we have learned to practice the knowledge acquired during the formative years and to manage our working time. Our job was to design and implementation of a device for measuring the energy of radiation. Our project meets the needs of users in the radio treatment Unit, which amount to automate measurement of radiation energy from the electron accelerator. This project has been beneficial on several levels: it was an opportunity to achieve better control of printed circuits, especially when they are dual layer and learning a new programming language that is actually BASIC. In human terms, this work has given us the opportunity to learn to manage our time, and learn teamwork. However, we are convinced that this project can be enhanced on various levels. It can be considered as a starting point of a contribution to the real-time measurement of the energy of radiation.

  2. Needs assessment and implementation of an employee assistance program: promoting a healthier work force.

    Science.gov (United States)

    Monfils, M K

    1995-05-01

    1. The functions of a continuous quality improvement tool used by Deming--the Plan, Do, Check, Act Cycle--can be applied to the assessment, implementation, and ongoing evaluation of an Employee Assistance Program (EAP). 2. Various methods are available to assess the need for an EAP. As much data as possible should be collected to qualify and quantify the need so that management can make an informed decision and develop measures to determine program effectiveness. 3. Once an EAP is implemented, it should be monitored continually against the effectiveness measures initially developed. Using a continuous quality improvement process, the occupational health nurse and the EAP provider can establish a dynamic relationship that allows for growth beyond the original design and increased effectiveness of service to employees.

  3. Predictable and SuStainable Implementation of National Cardiovascular Registries (PASSION) infrastructure: A think tank report from Medical Device Epidemiological Network Initiative (MDEpiNet).

    Science.gov (United States)

    Zeitler, Emily P; Al-Khatib, Sana M; Drozda, Joseph P; Kessler, Larry G; Kirtane, Ajay J; Kong, David F; Laschinger, John; Marinac-Dabic, Danica; Morice, Marie-Claude; Reed, Terrie; Sedrakyan, Art; Stein, Kenneth M; Tcheng, James; Krucoff, Mitchell W

    2016-01-01

    The MDEpiNet is a public-private partnership between the US Food and Drug Administration's Center for Devices and Radiological Health and participating partners. The PASSION program is an MDEpiNet-sponsored program that aims to demonstrate the goals of MDEpiNet by using cardiovascular medical device registries to bridge evidence gaps across the medical device total product life cycle. To this end, a PASSION Think Tank meeting took place in October 2014 in Silver Spring, MD, to facilitate discussion between stakeholders about the successes, challenges, and future novel applications of medical device registries, with particular emphasis on identifying pilot projects. Participants spanned a broad range of groups including patients, device manufacturers, regulators, physicians/academicians, professional societies, providers, and payers. The meeting focus included 4 areas of cardiovascular medicine intended to cultivate interest in 4 MDEpiNet disease-specific/device-specific working groups: coronary intervention, electrophysiology, valvular disease, and peripheral vascular disease. In addition, more general issues applying to registry-based infrastructure and analytical methodologies for assessing device benefit/risk were considered to provide context for the working groups as PASSION programs going forward. This article summarizes the discussions at the meeting and the future directions of the PASSION program. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Grade Point Average System of Assessment: the Implementation Peculiarities in Russia

    Directory of Open Access Journals (Sweden)

    B. A. Sazonov

    2012-01-01

    Full Text Available The paper analyzes the specificity, as well as flaws and faults of implementing the Grade Point Average (GPA system of students’ personal assessment in Russian higher schools. Nowadays, the above system is regarded as the basic functional element of educational process organization at the world’s leading universities. The author summarizes the foreign experience and demonstrates the advantages of the GPA system in comparison with the traditional domestic scale of assessment: full records of student’s assessment, objectivity, activation of responsibility for the results achieved, and self-control motivation. The standard GPA model is demonstrated, its application systemizing both the Russian and European requirements to the higher school graduates. The author suggests his own version of the assessment scale estimating and comparing the quality of education in Russian universities and worldwide. The research findings can be of interest to the specialists in the sphere of quality measurement and educational management. 

  5. An approach for management of mobile devices in pharmaceutical company

    OpenAIRE

    Prešeren, Tadej

    2008-01-01

    The areas of the mobile device management is developing very fast. Hence, the thesis “An approach for management of mobile devices in pharmaceutical company” introduces all key directives that should be considered when implementing mobile device management. A survey of standards and recommendations on the mobile device security has been elaborated. Relevant guidelines for security policy definition are presented with the risk analysis for mobile device usage. Furthermore, the model for mana...

  6. Issues in Assessment: Implementation.

    Science.gov (United States)

    Malinowski, Patricia A., Ed.

    This collection of articles is the third in a series on assessment produced by Finger Lakes Community College (New York). It deals with classroom assessment as an ongoing process that can be of significant value to teachers as well as to students. Assessment at the college and assessment in the classroom in general are explored. Articles include:…

  7. Transient electro-thermal modeling of bipolar power semiconductor devices

    CERN Document Server

    Gachovska, Tanya Kirilova; Du, Bin

    2013-01-01

    This book presents physics-based electro-thermal models of bipolar power semiconductor devices including their packages, and describes their implementation in MATLAB and Simulink. It is a continuation of our first book Modeling of Bipolar Power Semiconductor Devices. The device electrical models are developed by subdividing the devices into different regions and the operations in each region, along with the interactions at the interfaces, are analyzed using the basic semiconductor physics equations that govern device behavior. The Fourier series solution is used to solve the ambipolar diffusio

  8. Intelligent RF-Based Gesture Input Devices Implemented Using e-Textiles

    Directory of Open Access Journals (Sweden)

    Dana Hughes

    2017-01-01

    Full Text Available We present an radio-frequency (RF-based approach to gesture detection and recognition, using e-textile versions of common transmission lines used in microwave circuits. This approach allows for easy fabrication of input swatches that can detect a continuum of finger positions and similarly basic gestures, using a single measurement line. We demonstrate that the swatches can perform gesture detection when under thin layers of cloth or when weatherproofed, providing a high level of versatility not present with other types of approaches. Additionally, using small convolutional neural networks, low-level gestures can be identified with a high level of accuracy using a small, inexpensive microcontroller, allowing for an intelligent fabric that reports only gestures of interest, rather than a simple sensor requiring constant surveillance from an external computing device. The resulting e-textile smart composite has applications in controlling wearable devices by providing a simple, eyes-free mechanism to input simple gestures.

  9. Speech Recognition on Mobile Devices

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    in the mobile context covering motivations, challenges, fundamental techniques and applications. Three ASR architectures are introduced: embedded speech recognition, distributed speech recognition and network speech recognition. Their pros and cons and implementation issues are discussed. Applications within......The enthusiasm of deploying automatic speech recognition (ASR) on mobile devices is driven both by remarkable advances in ASR technology and by the demand for efficient user interfaces on such devices as mobile phones and personal digital assistants (PDAs). This chapter presents an overview of ASR...

  10. Implementation of a formal in-training assessment programme in anaesthesiology and preliminary results of acceptability

    DEFF Research Database (Denmark)

    Ringsted, C; Østergaard, D; van der Vleuten, C P M

    2003-01-01

    BACKGROUND: A new reform on postgraduate education in Denmark requires a formal in-training assessment in all specialties. The aim of this study was to survey the implementation and acceptability of the first example of a nation-wide in-training assessment programme for first-year trainees...... in anaesthesiology developed by a working group under the Danish Society of Anaesthesiology and Intensive Care Medicine. METHODS: A questionnaire about the implementation of the programme in practice and the characteristics of the trainees was sent to the educational responsible consultant (ERC) in each of the 26...... anaesthetic departments in the country with first-year trainees in anaesthesiology. Standard evaluations of the assessment programme were regularly collected from trainees. RESULTS: Twenty-five (96%) departments returned the questionnaire. In total the departments reported on 100 trainees and 83 of these had...

  11. Design, implementation, and extension of thermal invisibility cloaks

    Science.gov (United States)

    Zhang, Youming; Xu, Hongyi; Zhang, Baile

    2015-05-01

    A thermal invisibility cloak, as inspired by optical invisibility cloaks, is a device which can steer the conductive heat flux around an isolated object without changing the ambient temperature distribution so that the object can be "invisible" to external thermal environment. While designs of thermal invisibility cloaks inherit previous theories from optical cloaks, the uniqueness of heat diffusion leads to more achievable implementations. Thermal invisibility cloaks, as well as the variations including thermal concentrator, rotator, and illusion devices, have potentials to be applied in thermal management, sensing and imaging applications. Here, we review the current knowledge of thermal invisibility cloaks in terms of their design and implementation in cloaking studies, and their extension as other functional devices.

  12. Assessing the Influence of Smart Mobile Devices on How Employees Work

    Science.gov (United States)

    Gorski, Adam L.

    2017-01-01

    The smart mobile device market penetration reached 50% and has been increasing an average of 39% per year in the United States. More than 70% of the smart mobile device owners use such devices for personal and work activities. The problem was the lack of management's understanding of the effect smart mobile device use has on how employees work…

  13. 76 FR 21237 - Medical Devices; Obstetrical and Gynecological Devices; Classification of the Hemorrhoid...

    Science.gov (United States)

    2011-04-15

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... directs agencies to assess all costs and benefits of available regulatory alternatives and, when... economic, environmental, public health and safety, and other advantages; distributive impacts; and equity...

  14. User centered integration of Internet of Things devices

    Science.gov (United States)

    Manione, Roberto

    2017-06-01

    This paper discusses an IoT framework which allows rapid and easy setup and customization of end-to-end solutions for field data collection and presentation; it is effective in the development of both informative and transactional applications for a wide range of application fields, such as home, industry and environment. On the "far-end" of the chain are the IoT devices gathering the signals; they are developed used a full Model Based approach, where programming is not required: the TaskScript technology is used to this purpose, which supports a choice of physical boards and boxes equipped with a range of Input and Output interfaces, and with a Tcp/Ip interface. The development of the needed specific IoT devices takes advantage of the available "standard" hardware; the software development of the algorithms for sampling, conditioning and uploading signals to the Cloud is supported by a graphical-only IDE. On the "near-end" of the chain is the presentation Interface, through which users can browse through the information provided by their IoT devices; it is implemented in a Conversational way, using the Bot paradigm: Bots are conversational automatons, to whom users can "chat". They are accessed via mainstream Messenger programs, such as Telegram(C), Skype(C) or others, available on smartphones, tablets or desktops; unlike apps, bots do not need installation on the user device. A message Broker has been implemented, to mediate among the far-end and the near-end of the chain, providing the needed services; its behavior is driven by a set of rules provided on a per-device basis, at configuration level; the Broker is able to store messages received from the devices, process and forward them to the specified recipient(s) according to the provided rules; finally, finally is it is able to send transactional commands, from users back to the requested device, to implement not only field observation but also field control. IoT solutions implemented with the proposed

  15. An Evaluation of Video Modeling with Embedded Instructions to Teach Implementation of Stimulus Preference Assessments

    Science.gov (United States)

    Rosales, Rocío; Gongola, Leah; Homlitas, Christa

    2015-01-01

    A multiple baseline design across participants was used to evaluate the effects of video modeling with embedded instructions on training teachers to implement 3 preference assessments. Each assessment was conducted with a confederate learner or a child with autism during generalization probes. All teachers met the predetermined mastery criterion,…

  16. Implementation of a Mobile Clinical Decision Support Application to Augment Local Antimicrobial Stewardship.

    Science.gov (United States)

    Hoff, Brian M; Ford, Diana C; Ince, Dilek; Ernst, Erika J; Livorsi, Daniel J; Heintz, Brett H; Masse, Vincent; Brownlee, Michael J; Ford, Bradley A

    2018-01-01

    Medical applications for mobile devices allow clinicians to leverage microbiological data and standardized guidelines to treat patients with infectious diseases. We report the implementation of a mobile clinical decision support (CDS) application to augment local antimicrobial stewardship. We detail the implementation of our mobile CDS application over 20 months. Application utilization data were collected and evaluated using descriptive statistics to quantify the impact of our implementation. Project initiation focused on engaging key stakeholders, developing a business case, and selecting a mobile platform. The preimplementation phase included content development, creation of a pathway for content approval within the hospital committee structure, engaging clinical leaders, and formatting the first version of the guide. Implementation involved a media campaign, staff education, and integration within the electronic medical record and hospital mobile devices. The postimplementation phase required ongoing quality improvement, revision of outdated content, and repeated staff education. The evaluation phase included a guide utilization analysis, reporting to hospital leadership, and sustainability and innovation planning. The mobile application was downloaded 3056 times and accessed 9259 times during the study period. The companion web viewer was accessed 8214 times. Successful implementation of a customizable mobile CDS tool enabled our team to expand beyond microbiological data to clinical diagnosis, treatment, and antimicrobial stewardship, broadening our influence on antimicrobial prescribing and incorporating utilization data to inspire new quality and safety initiatives. Further studies are needed to assess the impact on antimicrobial utilization, infection control measures, and patient care outcomes.

  17. Flexible robotic entry device for a nuclear materials production reactor

    International Nuclear Information System (INIS)

    Heckendorn, F.M. II.

    1988-01-01

    The Savannah River Laboratory has developed and is implementing a flexible robotic entry device (FRED) for the nuclear materials production reactors now operating at the Savannah River Plant (SRP). FRED is designed for rapid deployment into confinement areas of operating reactors to assess unknown conditions. A unique smart tether method has been incorporated into FRED for simultaneous bidirectional transmission of multiple video/audio/control/power signals over a single coaxial cable. This system makes it possible to use FRED under all operating and standby conditions, including those where radio/microwave transmissions are not possible or permitted, and increases the quantity of data available

  18. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  19. Multifunctional Energy Storage and Conversion Devices.

    Science.gov (United States)

    Huang, Yan; Zhu, Minshen; Huang, Yang; Pei, Zengxia; Li, Hongfei; Wang, Zifeng; Xue, Qi; Zhi, Chunyi

    2016-10-01

    Multifunctional energy storage and conversion devices that incorporate novel features and functions in intelligent and interactive modes, represent a radical advance in consumer products, such as wearable electronics, healthcare devices, artificial intelligence, electric vehicles, smart household, and space satellites, etc. Here, smart energy devices are defined to be energy devices that are responsive to changes in configurational integrity, voltage, mechanical deformation, light, and temperature, called self-healability, electrochromism, shape memory, photodetection, and thermal responsivity. Advisable materials, device designs, and performances are crucial for the development of energy electronics endowed with these smart functions. Integrating these smart functions in energy storage and conversion devices gives rise to great challenges from the viewpoint of both understanding the fundamental mechanisms and practical implementation. Current state-of-art examples of these smart multifunctional energy devices, pertinent to materials, fabrication strategies, and performances, are highlighted. In addition, current challenges and potential solutions from materials synthesis to device performances are discussed. Finally, some important directions in this fast developing field are considered to further expand their application. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Development of weighting value for ecodrainage implementation assessment criteria

    Science.gov (United States)

    Andajani, S.; Hidayat, D. P. A.; Yuwono, B. E.

    2018-01-01

    This research aim to generate weighting value for each factor and find out the most influential factor for identify implementation of ecodrain concept using loading factor and Cronbach Alpha. The drainage problem especially in urban areas are getting more complex and need to be handled as soon as possible. Flood and drought problem can’t be solved by the conventional paradigm of drainage (to drain runoff flow as faster as possible to the nearest drainage area). The new paradigm of drainage that based on environmental approach called “ecodrain” can solve both of flood and drought problems. For getting the optimal result, ecodrain should be applied in smallest scale (domestic scale), until the biggest scale (city areas). It is necessary to identify drainage condition based on environmental approach. This research implement ecodrain concept by a guidelines that consist of parameters and assessment criteria. It was generating the 2 variables, 7 indicators and 63 key factors from previous research and related regulations. the conclusion of the research is the most influential indicator on technical management variable is storage system, while on non-technical management variable is government role.

  1. Fluid control structures in microfluidic devices

    Science.gov (United States)

    Mathies, Richard A.; Grover, William H.; Skelley, Alison; Lagally, Eric; Liu, Chung N.

    2017-05-09

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  2. Implementation of spacer therapy for acute asthma in children.

    LENUS (Irish Health Repository)

    Vandeleur, M

    2009-09-01

    The aim was to develop and implement an evidence based guideline for the treatment of acute asthma using a metered dose inhaler and spacer combination. Children admitted to Cork University Hospital Paediatric Department with acute asthma were identified during two identical 2 month seasonal periods before (2005) and after (2006) implementation of the new guidelines in September 2006. Pre-intervention and post-intervention audits by case note review were performed to determine the impact of and compliance with this evidence-based guideline emphasising patient assessment, spacer delivered bronchodilator and specific discharge criteria. Patients had similar characteristics during the two study periods. There was a raised threshold for admission after guideline implementation with 11\\/52 patients having mild exacerbations in 2006, compared to 21\\/36 in 2005. Duration of admission was less in the post-implementation group for equivalent exacerbation severity e.g. for moderate severity; 28 hours in 2005, 23 hours in 2006. Duration of bronchodilator therapy was shorter in 2006 and more likely to be given by spacer device earlier for equivalent levels of severity e.g. for moderate exacerbations, in 2006 the average length of salbutamol therapy was 18 hours with 12 hours by spacer device, in 2005 the average length of therapy was 25 hours with 3 hours by spacer. There was earlier initiation of oral corticosteroids; the average time to administration was 56 minutes in 2006 and 227 minutes in 2005. There was an improved documentation of asthma education in 2006 e.g. inhaler technique was reviewed in 37\\/52 in 2006, 21\\/35 in 2005 and better use of written action plans.

  3. Determination of Wave Model Uncertainties used for Probabilistic Reliability Assessments of Wave Energy Devices

    DEFF Research Database (Denmark)

    Ambühl, Simon; Kofoed, Jens Peter; Sørensen, John Dalsgaard

    2014-01-01

    Wave models used for site assessments are subject to model uncertainties, which need to be quantified when using wave model results for probabilistic reliability assessments. This paper focuses on determination of wave model uncertainties. Considered are four different wave models and validation...... data is collected from published scientific research. The bias, the root-mean-square error as well as the scatter index are considered for the significant wave height as well as the mean zero-crossing wave period. Based on an illustrative generic example it is shown how the estimated uncertainties can...... be implemented in probabilistic reliability assessments....

  4. Process evaluation of the implementation of scorecard-based antenatal risk assessment, care pathways and interdisciplinary consultation: the Healthy Pregnancy 4 All study.

    Science.gov (United States)

    Vos, A A; van Voorst, S F; Posthumus, A G; Waelput, A J M; Denktaş, S; Steegers, E A P

    2017-09-01

    To evaluate the implementation of a complex intervention in the antenatal healthcare field in 14 Dutch municipalities. The intervention consisted of the implementation of a systematic scorecard-based risk assessment in pregnancy, subsequent patient-tailored care pathways, and consultations of professionals from different medical and social disciplines. Saunders's seven-step method was used for the development of a programme implementation monitoring plan, with specific attention to the setting and context of the programme. Data were triangulated from multiple sources, and prespecified criteria were applied to examine the evidence for implementation. Six out of 11 municipalities (54%) met the implementation criteria for the entire risk assessment programme, whereas three municipalities (27%) met the criteria if the three components of implementation were analysed separately. A process evaluation of implementation of a complex intervention is possible. The results can be used to improve understanding of the associations between specific programme elements and programme outcomes on effectiveness of the intervention. Additionally, the results are important for formative purposes to assess how future implementation of antenatal risk assessment can be improved in comparable contexts. Copyright © 2017. Published by Elsevier Ltd.

  5. Identification and assessment of site treatment plan implementation opportunities for emerging technologies

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, E.A. [Sandia National Labs., Germantown, MD (United States)

    1995-12-31

    The Department of Energy (DOE), in response to the 1992 Federal Facility Compliance Act, has prepared Site Treatment Plans (STP) for the approximately 2,000 waste streams identified within its mixed waste inventory Concurrently, emerging mixed waste treatment technologies are in final development. This paper defines a three-phase process to identify and assess implementation opportunities for these emerging technologies within the STP. It highlights the first phase, functional matching of expected treatment capabilities with proposed treatment requirements. Matches are based on treatment type, regulated contaminant and waste matrix type, for both capabilities and requirements. Results identify specific waste streams and volumes that could be treated by each emerging technology. A study for Plasma Hearth Process, Delphi DETOX{sup sm}, Supercritical Water Oxidation and Vitrification shows that about 200,000 ml of DOE`s mixed waste inventory can potentially be treated by one or more of these emerging technologies. Actual implementations are small fractions of the treatable inventory. Differences between potential and actual implementations must be minimized to accrue optimum benefit from implementation of emerging or alternative treatment technologies. Functional matching is the first phase in identifying and quantifying benefits, addressing technology system and treatment issues, and providing, in part, the basis for STP implementation decisions. DOE, through EM`s Office of Technology Development, has funded this work.

  6. Developing evaluation instrument based on CIPP models on the implementation of portfolio assessment

    Science.gov (United States)

    Kurnia, Feni; Rosana, Dadan; Supahar

    2017-08-01

    This study aimed to develop an evaluation instrument constructed by CIPP model on the implementation of portfolio assessment in science learning. This study used research and development (R & D) method; adapting 4-D by the development of non-test instrument, and the evaluation instrument constructed by CIPP model. CIPP is the abbreviation of Context, Input, Process, and Product. The techniques of data collection were interviews, questionnaires, and observations. Data collection instruments were: 1) the interview guidelines for the analysis of the problems and the needs, 2) questionnaire to see level of accomplishment of portfolio assessment instrument, and 3) observation sheets for teacher and student to dig up responses to the portfolio assessment instrument. The data obtained was quantitative data obtained from several validators. The validators consist of two lecturers as the evaluation experts, two practitioners (science teachers), and three colleagues. This paper shows the results of content validity obtained from the validators and the analysis result of the data obtained by using Aikens' V formula. The results of this study shows that the evaluation instrument based on CIPP models is proper to evaluate the implementation of portfolio assessment instruments. Based on the experts' judgments, practitioners, and colleagues, the Aikens' V coefficient was between 0.86-1,00 which means that it is valid and can be used in the limited trial and operational field trial.

  7. Accuracy of Transthoracic Echocardiography in Assessing Retro-aortic Rim prior to Device Closure of Atrial Septal Defects.

    Science.gov (United States)

    O'Byrne, Michael L; Glatz, Andrew C; Goldberg, David J; Shinohara, Russell; Dori, Yoav; Rome, Jonathan J; Gillespie, Matthew J

    2015-01-01

    Deficient retro-aortic rim has been identified as a risk factor for device erosion following trans-catheter closure of atrial septal defects (ASDs). Transthoracic echocardiography (TTE) is the primary screening method for subjects for possible device closure of ASD, but its reliability in measuring retro-aortic rim size has not been assessed previously. A single-institution cross-sectional analysis of children and adults referred for trans-catheter device closure of single ostium secundum ASD from January 1, 2005 to April 1, 2012 with reviewable TTE and trans-esophageal echocardiogram images was performed. Inter-rater reliability of measurements was tested in a 24% sample. Accuracy of TTE measurement of retro-aortic rim was assessed using a Bland-Altman plot with trans-esophageal echocardiogram measurement as the gold standard. Test characteristics of TTE detection of deficient retro-aortic rim were calculated. Risk factors for misclassification of deficient retro-aortic rim were assessed using receiver operator characteristic curves. Risk factors for measurement error were assessed through multivariate linear regression. In total, 163 subjects of median age 5 years (range: 0.3-46 years) were included. Trans-thoracic echocardiography had 90% sensitivity, 84% specificity, 90% positive predictive value, and 83% negative predictive value to detect deficient retro-aortic rim. Bland-Altman plot demonstrated no fixed bias (P = .23), but errors in measurement increased on average as the aortic rim increased in size (P affect receiver operator characteristic curve area under the curve, nor were any patient-level risk factors independently associated with increased measurement error on TTE. TTE is a sensitive and specific screening test for deficient retro-aortic rim across a range of patient ages and sizes. © 2014 Wiley Periodicals, Inc.

  8. Assessing Implementation Fidelity and Adaptation in a Community-Based Childhood Obesity Prevention Intervention

    Science.gov (United States)

    Richards, Zoe; Kostadinov, Iordan; Jones, Michelle; Richard, Lucie; Cargo, Margaret

    2014-01-01

    Little research has assessed the fidelity, adaptation or integrity of activities implemented within community-based obesity prevention initiatives. To address this gap, a mixed-method process evaluation was undertaken in the context of the South Australian Obesity Prevention and Lifestyle (OPAL) initiative. An ecological coding procedure assessed…

  9. Light-pulse atom interferometric device

    Science.gov (United States)

    Biedermann, Grant; McGuinness, Hayden James Evans; Rakholia, Akash; Jau, Yuan-Yu; Schwindt, Peter; Wheeler, David R.

    2016-03-22

    An atomic interferometric device useful, e.g., for measuring acceleration or rotation is provided. The device comprises at least one vapor cell containing a Raman-active chemical species, an optical system, and at least one detector. The optical system is conformed to implement a Raman pulse interferometer in which Raman transitions are stimulated in a warm vapor of the Raman-active chemical species. The detector is conformed to detect changes in the populations of different internal states of atoms that have been irradiated by the optical system.

  10. Benchmarking Internet of Things devices

    CSIR Research Space (South Africa)

    Kruger, CP

    2014-07-01

    Full Text Available The use of commercial off-the-shelf components for implementing Internet of Things devices has become a common practice amongst researchers and solution providers. IOT solutions, based on the Raspberry Pi, BeagleBone and BeagleBone Black, offer cost...

  11. Researching implementation of formative assessment in different educational cultures in order to change educational policy

    DEFF Research Database (Denmark)

    Dolin, Jens

    2015-01-01

    This paper reports from a four year international research project, Assess Inquiry in Science, Technology and Mathematics Education (ASSIST-ME) involving 10 partners in 8 European countries (http://assistme.ku.dk/), running 2012-2016. The project combines research on implementation of innovative ...... assessment methods with a policy aspect in order to influence educational policy....

  12. The magazine picture collage: its clinical use and validity as an assessment device.

    Science.gov (United States)

    Lerner, C J

    1979-08-01

    To contribute to an understanding of the magazine picture collage as a clinical assessment device, experienced psychiatric staff from various disciplines were asked to distinguish the collages of hospitalized psychiatric patients from those of paired controls, to note whatever descriptive and dynamic features about the individual that could be inferred from the collage, and to document what specific aspects of the collage were used in drawing the inferences. The raters, on the basis of the collage, were not able to distinguish the patients from the controls but were able to derive highly accurate inferences. The results were taken to indicate that, while the collage is best used as a means of assessing psychological processes as contrasted with assigning a diagnosis or predicting behavior, more rigorous research is needed to relate collage factors to personality factors.

  13. Assessment of biofilm formation in device-associated clinical bacterial isolates in a tertiary level hospital

    Directory of Open Access Journals (Sweden)

    Summaiya A Mulla

    2011-01-01

    Full Text Available Background: Biofilm formation is a developmental process with intercellular signals that regulate growth. Biofilms contaminate catheters, ventilators, and medical implants; they act as a source of disease for humans, animals, and plants. Aim: In this study we have done quantitative assessment of biofilm formation in device-associated clinical bacterial isolates in response to various concentrations of glucose in tryptic soya broth and with different incubation time. Materials and Methods: The study was carried out on 100 positive bacteriological cultures of medical devices, which were inserted in hospitalized patients. The bacterial isolates were processed as per microtitre plate method with tryptic soya broth alone and with varying concentrations of glucose and were observed in response to time. Results: Majority of catheter cultures were positive. Out of the total 100 bacterial isolates tested, 88 of them were biofilm formers. Incubation period of 16-20 h was found to be optimum for biofilm development. Conclusions: Availability of nutrition in the form of glucose enhances the biofilm formation by bacteria. Biofilm formation depends on adherence of bacteria to various surfaces. Time and availability of glucose are important factors for assessment of biofilm progress.

  14. A simple nonlinear dynamical computing device

    International Nuclear Information System (INIS)

    Miliotis, Abraham; Murali, K.; Sinha, Sudeshna; Ditto, William L.; Spano, Mark L.

    2009-01-01

    We propose and characterize an iterated map whose nonlinearity has a simple (i.e., minimal) electronic implementation. We then demonstrate explicitly how all the different fundamental logic gates can be implemented and morphed using this nonlinearity. These gates provide the full set of gates necessary to construct a general-purpose, reconfigurable computing device. As an example of how such chaotic computing devices can be exploited, we use an array of these maps to encode data and to process information. Each map can store one of M items, where M is variable and can be large. This nonlinear hardware stores data naturally in different bases or alphabets. We also show how this method of storing information can serve as a preprocessing tool for exact or inexact pattern-matching searches.

  15. Identifying Barriers in Implementing Outcomes-Based Assessment Program Review: A Grounded Theory Analysis

    Science.gov (United States)

    Bresciani, Marilee J.

    2011-01-01

    The purpose of this grounded theory study was to identify the typical barriers encountered by faculty and administrators when implementing outcomes-based assessment program review. An analysis of interviews with faculty and administrators at nine institutions revealed a theory that faculty and administrators' promotion, tenure (if applicable),…

  16. Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients

    International Nuclear Information System (INIS)

    Baek, Jong Geal; Kim, Joo Ho; Lee, Sang Kyu; Lee, Won Joo; Yoon, Jong Won; Cho, Jeong Hee

    2008-01-01

    For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (33 cm and 55 cm) were used for comparison. Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 33 cm field and 55 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 33 cm field and 55 cm field respectively. Values from EBT film were higher. Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air

  17. Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jong Geal; Kim, Joo Ho; Lee, Sang Kyu; Lee, Won Joo; Yoon, Jong Won; Cho, Jeong Hee [Dept. of Radiation Oncology, Yensei Cancer Center, Yensei University Health System, Seoul (Korea, Republic of)

    2008-03-15

    For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (33 cm and 55 cm) were used for comparison. Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 33 cm field and 55 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 33 cm field and 55 cm field respectively. Values from EBT film were higher. Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air

  18. Portable Ultraviolet Light Surface-Disinfecting Devices for Prevention of Hospital-Acquired Infections: A Health Technology Assessment

    Science.gov (United States)

    Nikitovic-Jokic, Milica; Kabali, Conrad; Li, Chunmei; Higgins, Caroline

    2018-01-01

    Background Hospital-acquired infections (HAIs) are infections that patients contract while in the hospital that were neither present nor developing at the time of admission. In Canada an estimated 10% of adults with short-term hospitalization have HAIs. According to 2003 Canadian data, between 4% and 6% of these patients die from these infections. The most common HAIs in Ontario are caused by Clostridium difficile. The standard method of reducing and preventing these infections is decontamination of patient rooms through manual cleaning and disinfection. Several portable no-touch ultraviolet (UV) light systems have been proposed to supplement current hospital cleaning and disinfecting practices. Methods We searched for studies published from inception of UV disinfection technology to January 23, 2017. We compared portable UV surface-disinfecting devices used together with standard hospital room cleaning and disinfecting versus standard hospital cleaning and disinfecting alone. The primary outcome was HAI from C. difficile. Other outcomes were combined HAIs, colonization (i.e., carrying an infectious agent without exhibiting disease symptoms), and the HAI-associated mortality rate. We used Grading of Recommendations Assessment, Development, and Evaluation (GRADE) to rate the quality of evidence of included studies. We also performed a 5-year budget impact analysis from the hospital's perspective. This assessment was limited to portable devices and did not examine wall mounted devices, which are used in some hospitals. Results The database search for the clinical review yielded 10 peer-reviewed publications that met eligibility criteria. Three studies focused on mercury UV-C–based technology, seven on pulsed xenon UV technology. Findings were either inconsistent or produced very low-quality evidence using the GRADE rating system. The intervention was effective in reducing the rate of the composite outcome of HAIs (combined) and colonization (but quality of evidence

  19. The Implementation of Self-Assessment in Writing Class: A Case Study at STBA LIA Jakarta

    Science.gov (United States)

    Purwanti, Theresia Tuti

    2015-01-01

    Self-assessment has become a means of realizing the goals of learner-centered education. It is conducted to help students grow to be independent learners. With regard to this point, this case study is aimed at investigating the implementation of the self-assessment as a learning tool in writing class. Its purpose is to examine students' reactions…

  20. 76 FR 22322 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2010-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass Assessment Score Test System; Correction AGENCY: Food and Drug Administration, HHS. ACTION...

  1. A hybrid approach to device integration on a genetic analysis platform

    International Nuclear Information System (INIS)

    Brennan, Des; Justice, John; Aherne, Margaret; Galvin, Paul; Jary, Dorothee; Kurg, Ants; Berik, Evgeny; Macek, Milan

    2012-01-01

    Point-of-care (POC) systems require significant component integration to implement biochemical protocols associated with molecular diagnostic assays. Hybrid platforms where discrete components are combined in a single platform are a suitable approach to integration, where combining multiple device fabrication steps on a single substrate is not possible due to incompatible or costly fabrication steps. We integrate three devices each with a specific system functionality: (i) a silicon electro-wetting-on-dielectric (EWOD) device to move and mix sample and reagent droplets in an oil phase, (ii) a polymer microfluidic chip containing channels and reservoirs and (iii) an aqueous phase glass microarray for fluorescence microarray hybridization detection. The EWOD device offers the possibility of fully integrating on-chip sample preparation using nanolitre sample and reagent volumes. A key challenge is sample transfer from the oil phase EWOD device to the aqueous phase microarray for hybridization detection. The EWOD device, waveguide performance and functionality are maintained during the integration process. An on-chip biochemical protocol for arrayed primer extension (APEX) was implemented for single nucleotide polymorphism (SNiP) analysis. The prepared sample is aspirated from the EWOD oil phase to the aqueous phase microarray for hybridization. A bench-top instrumentation system was also developed around the integrated platform to drive the EWOD electrodes, implement APEX sample heating and image the microarray after hybridization. (paper)

  2. Assessment of implementation of COTPA-2003 in Bengaluru city, India: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Shweta Gururaj Habbu

    2015-01-01

    Full Text Available Introduction: Tobacco as a slow and modern epidemic remains a serious public health problem for the country. Despite the existence of a comprehensive law to reduce tobacco burden, India still faces the uphill task of its acceptance and successful implementation. Aim: To assess the implementation of Cigarettes and Other Tobacco Products Act 2003 (COTPA-2003 (Section 4, 6b, and 7 in public places of Bengaluru city and to assess the awareness of the head of these institutions/offices regarding COTPA-2003 and its enforcement in their premises. Materials and Methods: A cross-sectional study was conducted in 175 public places selected as sources of data using cluster random sampling. The tool in the form of a checklist was prepared based on the sections of COTPA-2003 (Cigarettes and Other Tobacco Products' Act, and data were recorded through direct observation. A structured interview was conducted of the institutional heads regarding the implementation of COTPA-2003 in their premises. Informed consent was obtained from the institutional heads or in-charges of the public places. Results: Section 4 (Prohibition of smoking in public places was not complied by 58%. Only 16.7% educational institutions complied with the Section 6b (Prohibition of sale of tobacco products near educational institutions. More than 50% of the head of the institutions were unaware of their role in the implementation of this law. Conclusion: Although the law has been drafted comprehensively, it is implemented only to a certain extent. Hence, all concerned departments and ministries responsible for meeting the framework convention on tobacco control objectives and enforcing COTPA, at central and state levels, should act urgently and in coordination.

  3. Implementing a Self- Checking PROFIBUS Slave

    OpenAIRE

    Krug, Margrit R.; Lubaszewski, Marcelo S.; Ferreira, Jose M.; Alves, Gustavo R.

    2000-01-01

    This work presents the study and preliminary results of the high level implementation of a self-checking Profibus slave. From an existing VHDL description of the device, a test strategy was studied and implemented, so that the whole circuit has embedded test structures capable to perform at-speed test of the slave. In this paper, we show the used test strategies and implementation results achieved from a synthesis process in a FPGA environment. info:eu-repo/semantics/publishedVersion

  4. Reliability of a Skin Diagnostic Device in Assessing Hydration and Erythema.

    Science.gov (United States)

    Huimin, Koh; Rowledge, Alexandra M; Borzdynski, Caroline J; Miller, Charne; Frescos, Nicoletta; McKenzie, Gayle; Perry, Elizabeth; McGuiness, William

    2017-10-01

    To examine the reliability of a skin diagnostic device, the SD202 (Courage+Khazaka GmBH, Cologne, Germany), in assessing hydration and erythema of periwound skin and pressure injury-prone areas. Intrarater reliabilities from 3 cross-sectional and prospective studies are reported. Patients attending an outpatient, nurse-led wound dressing clinic (n = 16), a podiatrist-led high-risk foot clinic (n = 17), and residents (n = 38) at a single residential aged-care facility. Skin hydration and erythema levels assessed using the SD202. High internal consistency was maintained for consecutive skin hydration and erythema measures at a single point on the venous leg ulcer periwound (α > .996 and α > .970 for hydration and erythema, respectively) and for the pressure-prone areas of the sacrum (α > .916), right (α > .994) and left (α > .967) ischium, right (α > .989) and left (α > .916) trochanter, right (α > .985) and left (α > .992) calcaneus, and right (α > .991) and left (α > .990) lateral malleolus. High consistency was also found for the measures obtained at 4 different locations around the periwound for the venous leg ulcer (α > .935 and α > .870 for hydration and erythema, respectively). In diabetic foot ulcer assessment, acceptable internal consistency of hydration measures around the periwound was observed (α > .634). Internal consistency of erythema measures was variable, ranging from low to high reliability, particularly among predebridement measures. Using the protocols outlined in this study, the SD202 demonstrates high reliability for assessing skin hydration and erythema levels. It is possible that the SD202 can be used in clinical practice as an appropriate tool for skin hydration and erythema assessment.

  5. Nanoscale RRAM-based synaptic electronics: toward a neuromorphic computing device.

    Science.gov (United States)

    Park, Sangsu; Noh, Jinwoo; Choo, Myung-Lae; Sheri, Ahmad Muqeem; Chang, Man; Kim, Young-Bae; Kim, Chang Jung; Jeon, Moongu; Lee, Byung-Geun; Lee, Byoung Hun; Hwang, Hyunsang

    2013-09-27

    Efforts to develop scalable learning algorithms for implementation of networks of spiking neurons in silicon have been hindered by the considerable footprints of learning circuits, which grow as the number of synapses increases. Recent developments in nanotechnologies provide an extremely compact device with low-power consumption.In particular, nanoscale resistive switching devices (resistive random-access memory (RRAM)) are regarded as a promising solution for implementation of biological synapses due to their nanoscale dimensions, capacity to store multiple bits and the low energy required to operate distinct states. In this paper, we report the fabrication, modeling and implementation of nanoscale RRAM with multi-level storage capability for an electronic synapse device. In addition, we first experimentally demonstrate the learning capabilities and predictable performance by a neuromorphic circuit composed of a nanoscale 1 kbit RRAM cross-point array of synapses and complementary metal-oxide-semiconductor neuron circuits. These developments open up possibilities for the development of ubiquitous ultra-dense, ultra-low-power cognitive computers.

  6. Nanoscale RRAM-based synaptic electronics: toward a neuromorphic computing device

    International Nuclear Information System (INIS)

    Park, Sangsu; Noh, Jinwoo; Choo, Myung-lae; Sheri, Ahmad Muqeem; Jeon, Moongu; Lee, Byung-Geun; Lee, Byoung Hun; Chang, Man; Kim, Young-Bae; Kim, Chang Jung; Hwang, Hyunsang

    2013-01-01

    Efforts to develop scalable learning algorithms for implementation of networks of spiking neurons in silicon have been hindered by the considerable footprints of learning circuits, which grow as the number of synapses increases. Recent developments in nanotechnologies provide an extremely compact device with low-power consumption. In particular, nanoscale resistive switching devices (resistive random-access memory (RRAM)) are regarded as a promising solution for implementation of biological synapses due to their nanoscale dimensions, capacity to store multiple bits and the low energy required to operate distinct states. In this paper, we report the fabrication, modeling and implementation of nanoscale RRAM with multi-level storage capability for an electronic synapse device. In addition, we first experimentally demonstrate the learning capabilities and predictable performance by a neuromorphic circuit composed of a nanoscale 1 kbit RRAM cross-point array of synapses and complementary metal–oxide–semiconductor neuron circuits. These developments open up possibilities for the development of ubiquitous ultra-dense, ultra-low-power cognitive computers. (paper)

  7. On the impact of medical device regulations on software architecture

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Manikas, Konstantinos

    2016-01-01

    Compliance to regulations and regulatory approval are requirements for many medical device software systems. In this paper, we investigate the implications of medical device software regulations to the design of software systems. We do so by focusing on the American and European regulatory author...... of the device. Moreover, we review software modularity in the implementation of software medical device and propose a set of preliminary principles for architectural design of software medical device based on a set of constrains identified from the reviewed regulations....

  8. [Projects to accelerate the practical use of innovative medical devices to collaborate with TWIns, Center for Advanced Biomedical Sciences, Waseda University and School of Engineering, The University of Tokyo].

    Science.gov (United States)

    Niimi, Shingo; Umezu, Mitsuo; Iseki, Hiroshi; Harada, Hiroshi Kasanuki Noboru; Mitsuishi, Mamoru; Kitamori, Takehiko; Tei, Yuichi; Nakaoka, Ryusuke; Haishima, Yuji

    2014-01-01

    Division of Medical Devices has been conducting the projects to accelerate the practical use of innovative medical devices to collaborate with TWIns, Center for Advanced Biomedical Sciences, Waseda University and School of Engineering, The University of Tokyo. The TWIns has been studying to aim at establishment of preclinical evaluation methods by "Engineering Based Medicine", and established Regulatory Science Institute for Medical Devices. School of Engineering, The University of Tokyo has been studying to aim at establishment of assessment methodology for innovative minimally invasive therapeutic devices, materials, and nanobio diagnostic devices. This report reviews the exchanges of personnel, the implement systems and the research progress of these projects.

  9. Assessing the current implementation of communicative language for English language teachers in Ethiopian Universities

    NARCIS (Netherlands)

    Anto, A.G.; Coenders, Ferdinand G.M.; Voogt, Joke

    2012-01-01

    This study has attempted to assess the current implementation of communicative language teaching (CLT) approach in two Ethiopian universities to identify professional development (PD) needs of English language teachers. A cross-sectional study using teachers, students and management as sources of

  10. Small Device For Short-Range Antenna Measurements Using Optics

    DEFF Research Database (Denmark)

    Yanakiev, Boyan Radkov; Nielsen, Jesper Ødum; Christensen, Morten

    2011-01-01

    This paper gives a practical solution for implementing an antenna radiation pattern measurement device using optical fibers. It is suitable for anechoic chambers as well as short range channel sounding. The device is optimized for small size and provides a cheap and easy way to make optical antenna...

  11. Assessment of RELAP5 MOD3.3 and CATHARE 2 V1.5A against a full scale test of PERSEO device

    International Nuclear Information System (INIS)

    Bianchi, F.; Meloni, P.; Ferri, R.; Achilli, A.

    2004-01-01

    PERSEO device was developed in the framework of a domestic research program on innovative safety systems, with the purpose to increase the reliability of passive Decay Heat Removal Systems implementing in-pool heat exchangers. The device was tested at SIET Thermal-hydraulic Research Centre by modifying the existing PANTHERS IC-PCC facility. Two types of tests were performed: integral tests and stability tests. The experimental data acquired in the test campaign allowed a validation of a RELAP5/mod 3.3 beta release and CATHARE2 V1.5a/Mod8.1 full scale model of the PERSEO device. The paper deals with the comparison between the two codes against an integral test considered representative from the point of view of the PERSEO functioning and it highlights capabilities and limits of the codes in simulating such kind of test. (authors)

  12. Assessing Cultural Readiness of Organization For Successful Implementation of Knowledge Managment, Appling FMCDM Approach: Case of Central Bank of Iran

    Directory of Open Access Journals (Sweden)

    Shaban Elahi

    2012-02-01

    Full Text Available Supportive organizational culture for knowledge management can vouch for successful implementation of knowledge management. In the case of lacking this kind of supportive culture, the organizational culture is one of the obstacles which can lead the implementation of knowledge management to full failure and waste of organizational assets. In this research, a framework based on FMCDM was utilized to assess the cultural readiness of organization as the knowledge management implementation prerequisite. This framework has been utilized to assess Central Bank of Iran’s cultural readiness. The methodology of research was descriptive and research data were gathered by questionnaire and were answered by experts and CBI executives. In this term, the cultural readiness of CBI was assessed and in accordance with this assessment, embarking on corrective action was proposed.

  13. Implementation and assessment of high-resolution numerical methods in TRACE

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dean, E-mail: wangda@ornl.gov [Oak Ridge National Laboratory, 1 Bethel Valley RD 6167, Oak Ridge, TN 37831 (United States); Mahaffy, John H.; Staudenmeier, Joseph; Thurston, Carl G. [U.S. Nuclear Regulatory Commission, Washington, DC 20555 (United States)

    2013-10-15

    Highlights: • Study and implement high-resolution numerical methods for two-phase flow. • They can achieve better numerical accuracy than the 1st-order upwind scheme. • They are of great numerical robustness and efficiency. • Great application for BWR stability analysis and boron injection. -- Abstract: The 1st-order upwind differencing numerical scheme is widely employed to discretize the convective terms of the two-phase flow transport equations in reactor systems analysis codes such as TRACE and RELAP. While very robust and efficient, 1st-order upwinding leads to excessive numerical diffusion. Standard 2nd-order numerical methods (e.g., Lax–Wendroff and Beam–Warming) can effectively reduce numerical diffusion but often produce spurious oscillations for steep gradients. To overcome the difficulties with the standard higher-order schemes, high-resolution schemes such as nonlinear flux limiters have been developed and successfully applied in numerical simulation of fluid-flow problems in recent years. The present work contains a detailed study on the implementation and assessment of six nonlinear flux limiters in TRACE. These flux limiters selected are MUSCL, Van Leer (VL), OSPRE, Van Albada (VA), ENO, and Van Albada 2 (VA2). The assessment is focused on numerical stability, convergence, and accuracy of the flux limiters and their applicability for boiling water reactor (BWR) stability analysis. It is found that VA and MUSCL work best among of the six flux limiters. Both of them not only have better numerical accuracy than the 1st-order upwind scheme but also preserve great robustness and efficiency.

  14. Implementation and assessment of high-resolution numerical methods in TRACE

    International Nuclear Information System (INIS)

    Wang, Dean; Mahaffy, John H.; Staudenmeier, Joseph; Thurston, Carl G.

    2013-01-01

    Highlights: • Study and implement high-resolution numerical methods for two-phase flow. • They can achieve better numerical accuracy than the 1st-order upwind scheme. • They are of great numerical robustness and efficiency. • Great application for BWR stability analysis and boron injection. -- Abstract: The 1st-order upwind differencing numerical scheme is widely employed to discretize the convective terms of the two-phase flow transport equations in reactor systems analysis codes such as TRACE and RELAP. While very robust and efficient, 1st-order upwinding leads to excessive numerical diffusion. Standard 2nd-order numerical methods (e.g., Lax–Wendroff and Beam–Warming) can effectively reduce numerical diffusion but often produce spurious oscillations for steep gradients. To overcome the difficulties with the standard higher-order schemes, high-resolution schemes such as nonlinear flux limiters have been developed and successfully applied in numerical simulation of fluid-flow problems in recent years. The present work contains a detailed study on the implementation and assessment of six nonlinear flux limiters in TRACE. These flux limiters selected are MUSCL, Van Leer (VL), OSPRE, Van Albada (VA), ENO, and Van Albada 2 (VA2). The assessment is focused on numerical stability, convergence, and accuracy of the flux limiters and their applicability for boiling water reactor (BWR) stability analysis. It is found that VA and MUSCL work best among of the six flux limiters. Both of them not only have better numerical accuracy than the 1st-order upwind scheme but also preserve great robustness and efficiency

  15. Software Tool Implementing the Fuzzy AHP Method in Ecological Risk Assessment

    Directory of Open Access Journals (Sweden)

    Radionovs Andrejs

    2017-12-01

    Full Text Available Due to the increased spread of invasive animals and plants in the territory of Latvia, the necessity of ecological risk assessment related to such kind of spread has grown lately. In cases with sufficient statistical data, the risk assessment may be successfully performed on the basis of statistical methods. The amount of statistical data in the context of spread of invasive animals and plants is pretty poor; therefore, the only method of ecological risk assessment remains subjective judgements of experts. The present paper proposes using a programming tool for ecological risk analysis elaborated by the authors. With the help of this programming tool the method of Fuzzy Analytical Hierarchical Process is implemented. The elements of the pairwise comparison matrix are allowed to be expressed by triangular and trapezoidal fuzzy sets. The presented tool makes it possible to design the fuzzy pair-wise comparison matrix and process the results in a user-friendly way.

  16. Downstream bioprocess characterisation within microfluidic devices

    DEFF Research Database (Denmark)

    Marques, Marco; Krühne, Ulrich; Szita, Nicolas

    2016-01-01

    developed which has, to some extent, hindered their implementation as early process development tools. Microfluidic devices are particularly attractive for using fewer resources, for having the possibility of parallelisation and for requiring fewer mechanical manipulations. The expectation...... is that these devices will facilitate the rapid definition of critical process parameters, and thus ultimately reduce production costs. We have developed several microfluidic mDUOs and combined them with advanced and novel analytical approaches, resulting in devices that can potentially be employed for both analytical...... for the liquid–liquid extraction of pharmaceuticals, for the purification and concentration of drug delivery vehicles, and for the flocculation of yeast cells in microfluidic devices. For the latter, we will present for the first time the capability to study flocculation-growth independent from the floc breakage...

  17. Analyzing the Implementation of an ERP System by Self-Assessment in Higher Education

    Science.gov (United States)

    Máté, Domicián; Bács, Zoltán; Takács, Viktor László

    2017-01-01

    Over the last few decades, not only organizations but also Higher Education Institutions should be more responsive to the demands of the changed global business environment and improve their effectiveness. Our motivation to write this paper is to assess the implementation of an Enterprise Resource Planning (ERP) system in higher education and…

  18. Design of a multimedia gateway for mobile devices

    Science.gov (United States)

    Hens, Raf; Goeminne, Nico; Van Hoecke, Sofie; Verdickt, Tom; Bouve, Thomas; Gielen, Frank; Demeester, Piet

    2005-03-01

    Although mobile users are currently offered a lot more capabilities on their mobile devices, they still experience some limitations. They can surf the Internet, read their e-mail and receive MMS messages, but they have limited processing power, storage capacity and bandwidth and are limited in their access to peripherals (e.g. printers). We have designed and implemented a multimedia gateway for mobile devices that reduces these limitations. It gives the mobile devices transparent access to high capacity devices connected to the gateway, which is built around a central, modularly extensible server that can run on any PC or home gateway. It manages two sets of modules: one set offering the actual services and another set handling the IP-based wireless interaction with the client applications on the mobile devices. These modules can be added and removed dynamically, offering new services on the fly. Currently services for storage, printing, domotics and playing music are provided. Others can easily be added later on. This paper discusses the architecture and development, the management of modules, the actual services and their benefits. Besides a proprietary implementation, it also looks into OSGi and how both platforms compare to each other, concerning design, architecture, ease of development, functionality, ...

  19. Implementation of a mechanical CPR device in a physician staffed HEMS - a prospective observational study.

    Science.gov (United States)

    Rauch, Simon; Strapazzon, Giacomo; Brodmann, Monika; Fop, Ernst; Masoner, Christian; Rauch, Lydia; Forti, Alessandro; Pietsch, Urs; Mair, Peter; Brugger, Hermann

    2018-04-28

    In this prospective, observational study we describe the incidence and characteristics of out of hospital cardiac arrest (OHCA) cases who received mechanical CPR, after the implementation of a mechanical CPR device (LUCAS 2; Physio Control, Redmond, WA, USA) in a physician staffed helicopter emergency medical service (HEMS) in South Tyrol, Italy. During the study period (06/2013-04/2016), 525 OHCA cases were registered by the dispatch centre, 271 (51.6%) were assisted by HEMS. LUCAS 2 was applied in 18 (6.6%) of all HEMS-assisted OHCA patients; ten were treated with LUCAS 2 at the scene only, and eight were transported to hospital with ongoing CPR. Two (11.1%) of the 18 patients survived long term with full neurologic recovery. In seven of eight patients transferred to hospital with ongoing CPR, CPR was ceased in the emergency room without further intervention. Retrospectively, all HEMS-assisted OHCA cases were screened for proposed indication criteria for prolonged CPR. Thirteen patients fulfilled these criteria, but only two of them were transported to hospital. Based on these results, we propose a standard operating procedure for HEMS-assisted patients with refractory OHCA in a region without hospitals with ECLS capacity.

  20. Bell nonlocality: a resource for device-independent quantum information protocols

    Science.gov (United States)

    Acin, Antonio

    2015-05-01

    Bell nonlocality is not only one of the most fundamental properties of quantum physics, but has also recently acquired the status of an information resource for device-independent quantum information protocols. In the device-independent approach, protocols are designed so that their performance is independent of the internal working of the devices used in the implementation. We discuss all these ideas and argue that device-independent protocols are especially relevant or cryptographic applications, as they are insensitive to hacking attacks exploiting imperfections on the modelling of the devices.

  1. Implementing and Assessing Inquiry-Based Learning through the CAREER Award

    Science.gov (United States)

    Brudzinski, M. R.

    2011-12-01

    In order to fully attain the benefits of inquiry-based learning, instructors who typically employ the traditional lecture format need to make many adjustments to their approach. This change in styles can be intimidating and logistically difficult to overcome, both for instructors and students, such that a stepwise approach to this transformation is likely to be more manageable. In this session, I will describe a series of tools to promote inquiry-based learning that I am helping to implement and assess in classroom courses and student research projects. I will demonstrate the importance of integrating with existing institutional initiatives as well as recognizing how student development plays a key role in student engagement. Some of the features I will highlight include: defining both student learning outcomes and student development outcomes, converting content training to be self-directed and asynchronous, utilizing conceptests to help students practice thinking like scientists, and employing both objective pre/post assessment and student self-reflective assessment. Lastly, I will reflect on how the well-defined goal of teaching and research integration in the CAREER award solicitation resonated with me even as an undergraduate and helped inspire my early career.

  2. Auxetic foam for snowsport safety devices

    OpenAIRE

    Allen, Tom; Duncan, Olly; Foster, Leon; Senior, Terry; Zampieri, Davide; Edeh, Victor; Alderson, Andrew

    2017-01-01

    Skiing and snowboarding are popular snow-sports with inherent risk of injury. There is potential to reduce the prevalence of injuries by improving and implementing snow-sport safety devices with the application of advanced materials. This paper investigates the application of auxetic foam to snow-sport safety devices. Composite pads - consisting of foam covered with a semi-rigid shell - were investigated as a simple model of body armour and a large 70 x 355 x 355 mm auxetic foam sample was fa...

  3. Implementing the IA stage and developing an instrument to assess the fidelity of critical time interventional: task shifting

    Directory of Open Access Journals (Sweden)

    Tatiana Fernandes Carpinteiro Silva

    2014-10-01

    Full Text Available One strategy that has been used for treat patients with mental health disorder is the implementation of psychosocial interventions. Like the development of a new drug, which requires safety studies before efficacy assessment, the psychosocial interventions should be implemented following defined stages, with the objective of increase the validity and reliability of such interventions. These stages are IA (pre-pilot, IB (pilot study, II (randomized clinical trial and III (additional studies. This study proposes a description of all activities carried out in implementation of the pre-pilot (IA Critical Time Intervention – Task Shifting (CTI-TS, including the development of manuals and the development of an instrument to assess fidelity to the original protocol. As a result, were performed the adaptation of instruments to be used in the pilot study, the adaptation of CTI-TS manual to Brazilian context, the adaptation of the agents CTI-TS training manual, as well the development of the CTI-TS assessment scale fidelity and its instruction manual. This allows multicentric studies conducted in different contexts could be performed avoiding biases. Considering that Brazil is a country that lacks resources allocated to mental care, it is expected that more psychosocial interventions can be implemented, since it was possible to develop the implementation process according to the methods recommended by the international scientific literature.

  4. Orientation of a 3D object: implementation with an artificial neural network using a programmable logic device

    International Nuclear Information System (INIS)

    Carnevale, Federico J.

    2010-01-01

    Complex information extraction from images is a key skill of intelligent machines, with wide application in automated systems, robotic manipulation and human-computer interaction. However, solving this problem with traditional, geometric or analytical, strategies is extremely difficult. Therefore, an approach based on learning from examples seems to be more appropriate. This thesis addresses the problem of 3D orientation, aiming to estimate the angular coordinates of a known object from an image shot from any direction. We describe a system based on artificial neural networks to solve this problem in real time. The implementation is performed using a programmable logic device. The digital system described in this paper has the ability to estimate two rotational coordinates of a 3D known object, in ranges from -80 0 to 80 0 . The operation speed allows a real time performance at video rate. The system accuracy can be successively increased by increasing the size of the artificial neural network and using a larger number of training examples [es

  5. The development and implementation of a decision-making capacity assessment model.

    Science.gov (United States)

    Parmar, Jasneet; Brémault-Phillips, Suzette; Charles, Lesley

    2015-03-01

    Decision-making capacity assessment (DMCA) is an issue of increasing importance for older adults. Current challenges need to be explored, and potential processes and strategies considered in order to address issues of DMCA in a more coordinated manner. An iterative process was used to address issues related to DMCA. This began with recognition of challenges associated with capacity assessments (CAs) by staff at Covenant Health (CH). Review of the literature, as well as discussions with and a survey of staff at three CH sites, resulted in determination of issues related to DMCA. Development of a DMCA Model and demonstration of its feasibility followed. A process was proposed with front-end screening/problem- solving, a well-defined standard assessment, and definition of team member roles. A Capacity Assessment Care Map was formulated based on the process. Documentation was developed consisting of a Capacity Assessment Process Worksheet, Capacity Interview Worksheet, and a brochure. Interactive workshops were delivered to familiarize staff with the DMCA Model. A successful demonstration project led to implementation across all sites in the Capital Health region, and eventual provincial endorsement. Concerns identified in the survey and in the literature regarding CA were addressed through the holistic interdisciplinary approach offered by the DMCA Model.

  6. High-performance spinning device for DVD-based micromechanical signal transduction

    DEFF Research Database (Denmark)

    Hwu, En-Te; Chen, Ching-Hsiu; Bosco, Filippo

    2013-01-01

    Here we report a high-throughput spinning device for nanometric scale measurements of microstructures with instrumentation details and experimental results. The readout technology implemented in the designed disc-like device is based on a DVD data storage optical pick-up unit (OPU). With a spinning...

  7. Analysis of fluctuations in semiconductor devices

    Science.gov (United States)

    Andrei, Petru

    The random nature of ion implantation and diffusion processes as well as inevitable tolerances in fabrication result in random fluctuations of doping concentrations and oxide thickness in semiconductor devices. These fluctuations are especially pronounced in ultrasmall (nanoscale) semiconductor devices when the spatial scale of doping and oxide thickness variations become comparable with the geometric dimensions of devices. In the dissertation, the effects of these fluctuations on device characteristics are analyzed by using a new technique for the analysis of random doping and oxide thickness induced fluctuations. This technique is universal in nature in the sense that it is applicable to any transport model (drift-diffusion, semiclassical transport, quantum transport etc.) and it can be naturally extended to take into account random fluctuations of the oxide (trapped) charges and channel length. The technique is based on linearization of the transport equations with respect to the fluctuating quantities. It is computationally much (a few orders of magnitude) more efficient than the traditional Monte-Carlo approach and it yields information on the sensitivity of fluctuations of parameters of interest (e.g. threshold voltage, small-signal parameters, cut-off frequencies, etc.) to the locations of doping and oxide thickness fluctuations. For this reason, it can be very instrumental in the design of fluctuation-resistant structures of semiconductor devices. Quantum mechanical effects are taken into account by using the density-gradient model as well as through self-consistent Poisson-Schrodinger computations. Special attention is paid to the presenting of the technique in a form that is suitable for implementation on commercial device simulators. The numerical implementation of the technique is discussed in detail and numerous computational results are presented and compared with those previously published in literature.

  8. Field-Programmable Logic Devices with Optical Input Output

    Science.gov (United States)

    Szymanski, Ted H.; Saint-Laurent, Martin; Tyan, Victor; Au, Albert; Supmonchai, Boonchuay

    2000-02-01

    A field-programmable logic device (FPLD) with optical I O is described. FPLD s with optical I O can have their functionality specified in the field by means of downloading a control-bit stream and can be used in a wide range of applications, such as optical signal processing, optical image processing, and optical interconnects. Our device implements six state-of-the-art dynamically programmable logic arrays (PLA s) on a 2 mm 2 mm die. The devices were fabricated through the Lucent Technologies Advanced Research Projects Agency Consortium for Optical and Optoelectronic Technologies in Computing (Lucent ARPA COOP) workshop by use of 0.5- m complementary metal-oxide semiconductor self-electro-optic device technology and were delivered in 1998. All devices are fully functional: The electronic data paths have been verified at 200 MHz, and optical tests are pending. The device has been programmed to implement a two-stage optical switching network with six 4 4 crossbar switches, which can realize more than 190 10 6 unique programmable input output permutations. The same device scaled to a 2 cm 2 cm substrate could support as many as 4000 optical I O and 1 Tbit s of optical I O bandwidth and offer fully programmable digital functionality with approximately 110,000 programmable logic gates. The proposed optoelectronic FPLD is also ideally suited to realizing dense, statically reconfigurable crossbar switches. We describe an attractive application area for such devices: a rearrangeable three-stage optical switch for a wide-area-network backbone, switching 1000 traffic streams at the OC-48 data rate and supporting several terabits of traffic.

  9. 76 FR 43119 - Medical Devices; General and Plastic Surgery Devices; Classification of the Focused Ultrasound...

    Science.gov (United States)

    2011-07-20

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... Orders 12866 and 13563 direct Agencies to assess all costs and benefits of available regulatory... (including potential economic, environmental, public health and safety, and other advantages; distributive...

  10. Medical device market in China.

    Science.gov (United States)

    Boyer, Philip; Morshed, Bashir I; Mussivand, Tofy

    2015-06-01

    With China's growing old-age population and economic presence on the international stage, it has become important to evaluate its domestic and foreign market contribution to medical devices. Medical devices are instruments or apparatuses used in the prevention, rehabilitation, treatment, or knowledge generation with respect to disease or other abnormal conditions. This article provides information drawn from recent publications to describe the current state of the Chinese domestic market for medical devices and to define opportunities for foreign investment potential therein. Recent healthcare reforms implemented to meet rising demand due to an aging and migrating population are having a positive effect on market growth-a global market with a projected growth of 15% per year over the next decade. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  11. Combining multi-criteria decision analysis and mini-health technology assessment: A funding decision-support tool for medical devices in a university hospital setting.

    Science.gov (United States)

    Martelli, Nicolas; Hansen, Paul; van den Brink, Hélène; Boudard, Aurélie; Cordonnier, Anne-Laure; Devaux, Capucine; Pineau, Judith; Prognon, Patrice; Borget, Isabelle

    2016-02-01

    At the hospital level, decisions about purchasing new and oftentimes expensive medical devices must take into account multiple criteria simultaneously. Multi-criteria decision analysis (MCDA) is increasingly used for health technology assessment (HTA). One of the most successful hospital-based HTA approaches is mini-HTA, of which a notable example is the Matrix4value model. To develop a funding decision-support tool combining MCDA and mini-HTA, based on Matrix4value, suitable for medical devices for individual patient use in French university hospitals - known as the IDA tool, short for 'innovative device assessment'. Criteria for assessing medical devices were identified from a literature review and a survey of 18 French university hospitals. Weights for the criteria, representing their relative importance, were derived from a survey of 25 members of a medical devices committee using an elicitation technique involving pairwise comparisons. As a test of its usefulness, the IDA tool was applied to two new drug-eluting beads (DEBs) for transcatheter arterial chemoembolization. The IDA tool comprises five criteria and weights for each of two over-arching categories: risk and value. The tool revealed that the two new DEBs conferred no additional value relative to DEBs currently available. Feedback from participating decision-makers about the IDA tool was very positive. The tool could help to promote a more structured and transparent approach to HTA decision-making in French university hospitals. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Health technology assessment to optimize health technology utilization: using implementation initiatives and monitoring processes.

    Science.gov (United States)

    Frønsdal, Katrine B; Facey, Karen; Klemp, Marianne; Norderhaug, Inger Natvig; Mørland, Berit; Røttingen, John-Arne

    2010-07-01

    The way in which a health technology is used in any particular health system depends on the decisions and actions of a variety of stakeholders, the local culture, and context. In 2009, the HTAi Policy Forum considered how health technology assessment (HTA) could be improved to optimize the use of technologies (in terms of uptake, change in use, or disinvestment) in such complex systems. In scoping, it was agreed to focus on initiatives to implement evidence-based guidance and monitoring activities. A review identified systematic reviews of implementation initiatives and monitoring activities. A two-day deliberative workshop was held to discuss key papers, members' experiences, and collectively address key questions. This consensus paper was developed by email and finalized at a postworkshop meeting. Evidence suggests that the impact and use of HTA could be increased by ensuring timely delivery of relevant reports to clearly determined policy receptor (decision-making) points. To achieve this, the breadth of assessment, implementation initiatives such as incentives and targeted, intelligent dissemination of HTA result, needs to be considered. HTA stakeholders undertake a variety of monitoring activities, which could inform optimal use of a technology. However, the quality of these data varies and is often not submitted to an HTA. Monitoring data should be sufficiently robust so that they can be used in HTA to inform optimal use of technology. Evidence-based implementation initiatives should be developed for HTA, to better inform decision makers at all levels in a health system about the optimal use of technology.

  13. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  14. LEGO firm devices for atomic industry

    International Nuclear Information System (INIS)

    Makarov, P.V.; Egunova, E.M.

    2007-01-01

    Analytical problems of atomic industry enterprises are considered. Possibilities of LECO firm devices for following analysis kinds: 1) ore materials under ore processing; 2) chemical composition analysis and properties of metals and oxides under implementation of production manufacturing for nuclear industry; 3) spectral analysis; 4) structure analysis and properties of metallic materials - are shown. All above-listed analysis methods are applying at quality control operation. Examples of LECO device application at different nuclear energy enterprises of Russia, Kazakhstan, and other CIS and Baltic countries are cited

  15. Aging assessment of surge protective devices in nuclear power plants

    International Nuclear Information System (INIS)

    Davis, J.F.; Subudhi, M.; Carroll, D.P.

    1996-01-01

    An assessment was performed to determine the effects of aging on the performance and availability of surge protective devices (SPDs), used in electrical power and control systems in nuclear power plants. Although SPDs have not been classified as safety-related, they are risk-important because they can minimize the initiating event frequencies associated with loss of offsite power and reactor trips. Conversely, their failure due to age might cause some of those initiating events, e.g., through short circuit failure modes, or by allowing deterioration of the safety-related component(s) they are protecting from overvoltages, perhaps preventing a reactor trip, from an open circuit failure mode. From the data evaluated during 1980--1994, it was found that failures of surge arresters and suppressers by short circuits were neither a significant risk nor safety concern, and there were no failures of surge suppressers preventing a reactor trip. Simulations, using the ElectroMagnetic Transients Program (EMTP) were performed to determine the adequacy of high voltage surge arresters

  16. The design and implementation of device operation and management system based on LAMP

    International Nuclear Information System (INIS)

    Liu Shuzhen; Ma Lanxin; Qi Fazhi

    2010-01-01

    In order to manage devices with high efficiency and high quality and make it more standardized, more scientific and more modern, we use the platform of LAMP (Linux-Apache-Mysql-PHP) to develop a web-based equipment operation and management system. It uses the Browser/Server mode as the system mode and Mysql as the database to complete the function, such as query, modify, add, delete, batch import, batch export user information and device information, automatic alarm, user reviews and so on. (authors)

  17. Risk evaluation of medical and industrial radiation devices

    International Nuclear Information System (INIS)

    Jones, E.D.; Cunningham, R.E.; Rathbun, P.A.

    1994-03-01

    In 1991, the NRC, Division of Industrial and Medical Nuclear Safety, began a program to evaluate the use of probabilistic risk assessment (PRA) in regulating medical devices. This program represents an initial step in an overall plant to evaluate the use of PRA in regulating the use of nuclear by-product materials. The NRC envisioned that the use of risk analysis techniques could assist staff in ensuring that the regulatory approach was standardized, understandable, and effective. Traditional methods of assessing risk in nuclear power plants may be inappropriate to use in assessing the use of by-product devices. The approaches used in assessing nuclear reactor risks are equipment-oriented. Secondary attention is paid to the human component, for the most part after critical system failure events have been identified. This paper describes the risk methodology developed by Lawrence Livermore National Laboratory (LLNL), initially intended to assess risks associated with the use of the Gamma Knife, a gamma stereotactic radiosurgical device. For relatively new medical devices such as the Gamma Knife, the challenge is to perform a risk analysis with very little quantitative data but with an important human factor component. The method described below provides a basic approach for identifying the most likely risk contributors and evaluating their relative importance. The risk analysis approach developed for the Gamma Knife and described in this paper should be applicable to a broader class of devices in which the human interaction with the device is a prominent factor. In this sense, the method could be a prototypical model of nuclear medical or industrial device risk analysis

  18. What do stakeholders need to implement shared decision making in routine cancer care? A qualitative needs assessment.

    Science.gov (United States)

    Müller, Evamaria; Hahlweg, Pola; Scholl, Isabelle

    2016-12-01

    Shared decision making (SDM) is particularly relevant in oncology, where complex treatment options with varying side effects may lead to meaningful changes in the patient's quality of life. For several years, health policies have called for the implementation of SDM, but SDM remains poorly implemented in routine clinical practice. Implementation science has highlighted the importance of assessing stakeholders' needs to inform the development of implementation programs. Thus, the aim of the present study was to assess different stakeholders' needs regarding the implementation of SDM in routine care. A qualitative study using focus groups and interviews was conducted. Focus groups were carried out with junior physicians, senior physicians, nurses and other healthcare providers (HPCs) (e.g. psycho-oncologists, physiotherapists), patients and family members. Head physicians as well as other HPCs in management positions were interviewed. Audiotapes of focus groups and interviews were transcribed verbatim and analyzed using content analysis. Six focus groups with a total of n = 42 stakeholders as well as n = 17 interviews were conducted. Focus groups and interviews revealed five main categories of needs to be fulfilled in order to achieve a better implementation of SDM in routine cancer care: 1) changes in communication, 2) involvement of other parties, 3) a trustful patient-physician relationship, 4) culture change and 5) structural changes. Stakeholders discussed four clusters of intervention strategies that could foster the implementation of SDM in routine cancer care: 1) clinician-mediated interventions, 2) patient-mediated interventions, 3) provision of patient information material and 4) the establishment of a patient advocate. Study results show that stakeholders voiced a diversity of needs to foster implementation of SDM in routine cancer care, of which some can be directly addressed by intervention strategies. Present results can be used to develop an

  19. Semiconductor devices for all-optical regeneration

    DEFF Research Database (Denmark)

    Öhman, Filip; Bischoff, Svend; Tromborg, Bjarne

    2003-01-01

    We review different implementations of semiconductor devices for all-optical regeneration. A general model will be presented for all-optical regeneration in fiber links, taking into consideration the trade-off between non-linearity and noise. Furthermore we discuss a novel regenerator type, based...

  20. Assessment of three frequently used blood glucose monitoring devices in clinical routine.

    Science.gov (United States)

    Zueger, Thomas; Schuler, Vanessa; Stettler, Christoph; Diem, Peter; Christ, Emanuel R

    2012-07-12

    Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice. Capillary blood glucose was measured simultaneous using the following glucose meters: Contour® (Bayer Diabetes Care, Zürich, Switzerland), Accu-Chek® aviva (Roche Diagnostics, Rotkreuz, Switzerland), Free-Style® lite (Abbott Diabetes Care, Baar, Switzerland). The reference method consisted of the HemoCue® Glucose 201+ System (HemoCue® AB, Ängelholm, Sweden) with plasma conversion. The devices were assessed by comparison of the Mean Absolute Relative Differences (MARD), the Clarke Error Grid Analysis (EGA) and the compliance with the International Organization of Standardization criteria (ISO 15197:2003). Capillary blood samples were obtained from 150 patients. MARD was 10.1 ± 0.65%, 7.0 ± 0.62% and 7.8 ± 0.48% for Contour®, Accu-Chek® and Free-Style®, respectively. EGA showed 99.3% (Contour®), 98.7% (Accu-Chek®) and 100% (Free-Style®) of all measurements in zone A and B (clinically acceptable). The ISO criteria were fulfilled by Accu-Chek® (95.3%) and Free-Style® (96%), but not by Contour® (92%). In the present study the three glucose meters provided good agreement with the reference and reliable results in daily clinical routine. Overall, the Free-Style® and Accu-Chek® device slightly outperformed the Contour® device.

  1. Imaging assessment of a portable hemodialysis device: detection of possible failure modes and monitoring of functional performance.

    Science.gov (United States)

    Olorunsola, Olufoladare G; Kim, Steven H; Chang, Ryan; Kuo, Yuo-Chen; Hetts, Steven W; Heller, Alex; Kant, Rishi; Saeed, Maythem; Fissell, William H; Roy, Shuvo; Wilson, Mark W

    2014-03-27

    The purpose of this study was to investigate the utility and limitations of various imaging modalities in the noninvasive assessment of a novel compact hemodialyzer under development for renal replacement therapy, with specific aim towards monitoring its functional performance. The prototype is a 4×3×6 cm aluminum cartridge housing "blood" and "dialysate" flow paths arranged in parallel. A sheet of semipermeable silicon nanopore membranes forms the blood-dialysate interface, allowing passage of small molecules. Blood flow was simulated using a peristaltic pump to instill iodinated contrast through the blood compartment, while de-ionized water was instilled through the dialysate compartment at a matched rate in the countercurrent direction. Images were acquired under these flow conditions using multi-detector computed tomography (MDCT), fluoroscopy, high-resolution quantitative computed tomography (HR-QCT), and magnetic resonance imaging (MRI). MDCT was used to monitor contrast diffusion efficiency by plotting contrast density as a function of position along the path of flow through the cartridge during steady state infusion at 1 and 20 mL/min. Both linear and exponential regressions were used to model contrast decay along the flow path. Both linear and exponential models of contrast decay appeared to be reasonable approximations, yielding similar results for contrast diffusion during a single pass through the cartridge. There was no measurable difference in contrast diffusion when comparing 1 mL/min and 20 mL/min flow rates. Fluoroscopy allowed a gross qualitative assessment of flow within the device, and revealed flow inhomogeneity within the corner of the cartridge opposite the blood inlet port. MRI and HR-QCT were both severely limited due to the paramagnetic properties and high atomic number of the target material, respectively. During testing, we encountered several causes of device malfunction, including leak formation, trapped gas, and contrast

  2. Life Cycle Assessment and Costing Methods for Device Procurement: Comparing Reusable and Single-Use Disposable Laryngoscopes.

    Science.gov (United States)

    Sherman, Jodi D; Raibley, Lewis A; Eckelman, Matthew J

    2018-01-09

    Traditional medical device procurement criteria include efficacy and safety, ease of use and handling, and procurement costs. However, little information is available about life cycle environmental impacts of the production, use, and disposal of medical devices, or about costs incurred after purchase. Reusable and disposable laryngoscopes are of current interest to anesthesiologists. Facing mounting pressure to quickly meet or exceed conflicting infection prevention guidelines and oversight body recommendations, many institutions may be electively switching to single-use disposable (SUD) rigid laryngoscopes or overcleaning reusables, potentially increasing both costs and waste generation. This study provides quantitative comparisons of environmental impacts and total cost of ownership among laryngoscope options, which can aid procurement decision making to benefit facilities and public health. We describe cradle-to-grave life cycle assessment (LCA) and life cycle costing (LCC) methods and apply these to reusable and SUD metal and plastic laryngoscope handles and tongue blade alternatives at Yale-New Haven Hospital (YNHH). The US Environmental Protection Agency's Tool for the Reduction and Assessment of Chemical and other environmental Impacts (TRACI) life cycle impact assessment method was used to model environmental impacts of greenhouse gases and other pollutant emissions. The SUD plastic handle generates an estimated 16-18 times more life cycle carbon dioxide equivalents (CO2-eq) than traditional low-level disinfection of the reusable steel handle. The SUD plastic tongue blade generates an estimated 5-6 times more CO2-eq than the reusable steel blade treated with high-level disinfection. SUD metal components generated much higher emissions than all alternatives. Both the SUD handle and SUD blade increased life cycle costs compared to the various reusable cleaning scenarios at YNHH. When extrapolated over 1 year (60,000 intubations), estimated costs increased

  3. Development of the evaluation instrument use CIPP on the implementation of project assessment topic optik

    Science.gov (United States)

    Asfaroh, Jati Aurum; Rosana, Dadan; Supahar

    2017-08-01

    This research aims to develop an evaluation instrument models CIPP valid and reliable as well as determine the feasibility and practicality of an evaluation instrument models CIPP. An evaluation instrument models CIPP to evaluate the implementation of the project assessment topic optik to measure problem-solving skills of junior high school class VIII in the Yogyakarta region. This research is a model of development that uses 4-D. Subject of product trials are students in class VIII SMP N 1 Galur and SMP N 1 Sleman. Data collection techniques in this research using non-test techniques include interviews, questionnaires and observations. Validity in this research was analyzed using V'Aikens. Reliability analyzed using ICC. This research uses 7 raters are derived from two lecturers expert (expert judgment), two practitioners (science teacher) and three colleagues. The results of this research is the evaluation's instrument model of CIPP is used to evaluate the implementation of the implementation of the project assessment instruments. The validity result of evaluation instrument have V'Aikens values between 0.86 to 1, which means a valid and 0.836 reliability values into categories so well that it has been worth used as an evaluation instrument.

  4. Algorithms for the extension of precise and imprecise conditional probability assessments: an implementation with maple V

    Directory of Open Access Journals (Sweden)

    Veronica Biazzo

    2000-05-01

    Full Text Available In this paper, we illustrate an implementation with Maple V of some procedures which allow to exactly propagate precise and imprecise probability assessments. The extension of imprecise assessments is based on a suitable generalization of the concept of coherence of de Finetti. The procedures described are supported by some examples and relevant cases.

  5. A confirmative clinimetric analysis of the 36-item Family Assessment Device.

    Science.gov (United States)

    Timmerby, Nina; Cosci, Fiammetta; Watson, Maggie; Csillag, Claudio; Schmitt, Florence; Steck, Barbara; Bech, Per; Thastum, Mikael

    2018-02-07

    The Family Assessment Device (FAD) is a 60-item questionnaire widely used to evaluate self-reported family functioning. However, the factor structure as well as the number of items has been questioned. A shorter and more user-friendly version of the original FAD-scale, the 36-item FAD, has therefore previously been proposed, based on findings in a nonclinical population of adults. We aimed in this study to evaluate the brief 36-item version of the FAD in a clinical population. Data from a European multinational study, examining factors associated with levels of family functioning in adult cancer patients' families, were used. Both healthy and ill parents completed the 60-item version FAD. The psychometric analyses conducted were Principal Component Analysis and Mokken-analysis. A total of 564 participants were included. Based on the psychometric analysis we confirmed that the 36-item version of the FAD has robust psychometric properties and can be used in clinical populations. The present analysis confirmed that the 36-item version of the FAD (18 items assessing 'well-being' and 18 items assessing 'dysfunctional' family function) is a brief scale where the summed total score is a valid measure of the dimensions of family functioning. This shorter version of the FAD is, in accordance with the concept of 'measurement-based care', an easy to use scale that could be considered when the aim is to evaluate self-reported family functioning.

  6. Organizational readiness for implementing change: a psychometric assessment of a new measure.

    Science.gov (United States)

    Shea, Christopher M; Jacobs, Sara R; Esserman, Denise A; Bruce, Kerry; Weiner, Bryan J

    2014-01-10

    Organizational readiness for change in healthcare settings is an important factor in successful implementation of new policies, programs, and practices. However, research on the topic is hindered by the absence of a brief, reliable, and valid measure. Until such a measure is developed, we cannot advance scientific knowledge about readiness or provide evidence-based guidance to organizational leaders about how to increase readiness. This article presents results of a psychometric assessment of a new measure called Organizational Readiness for Implementing Change (ORIC), which we developed based on Weiner's theory of organizational readiness for change. We conducted four studies to assess the psychometric properties of ORIC. In study one, we assessed the content adequacy of the new measure using quantitative methods. In study two, we examined the measure's factor structure and reliability in a laboratory simulation. In study three, we assessed the reliability and validity of an organization-level measure of readiness based on aggregated individual-level data from study two. In study four, we conducted a small field study utilizing the same analytic methods as in study three. Content adequacy assessment indicated that the items developed to measure change commitment and change efficacy reflected the theoretical content of these two facets of organizational readiness and distinguished the facets from hypothesized determinants of readiness. Exploratory and confirmatory factor analysis in the lab and field studies revealed two correlated factors, as expected, with good model fit and high item loadings. Reliability analysis in the lab and field studies showed high inter-item consistency for the resulting individual-level scales for change commitment and change efficacy. Inter-rater reliability and inter-rater agreement statistics supported the aggregation of individual level readiness perceptions to the organizational level of analysis. This article provides evidence in

  7. Ultrathin conformal devices for precise and continuous thermal characterization of human skin

    Science.gov (United States)

    Webb, R. Chad; Bonifas, Andrew P.; Behnaz, Alex; Zhang, Yihui; Yu, Ki Jun; Cheng, Huanyu; Shi, Mingxing; Bian, Zuguang; Liu, Zhuangjian; Kim, Yun-Soung; Yeo, Woon-Hong; Park, Jae Suk; Song, Jizhou; Li, Yuhang; Huang, Yonggang; Gorbach, Alexander M.; Rogers, John A.

    2013-10-01

    Precision thermometry of the skin can, together with other measurements, provide clinically relevant information about cardiovascular health, cognitive state, malignancy and many other important aspects of human physiology. Here, we introduce an ultrathin, compliant skin-like sensor/actuator technology that can pliably laminate onto the epidermis to provide continuous, accurate thermal characterizations that are unavailable with other methods. Examples include non-invasive spatial mapping of skin temperature with millikelvin precision, and simultaneous quantitative assessment of tissue thermal conductivity. Such devices can also be implemented in ways that reveal the time-dynamic influence of blood flow and perfusion on these properties. Experimental and theoretical studies establish the underlying principles of operation, and define engineering guidelines for device design. Evaluation of subtle variations in skin temperature associated with mental activity, physical stimulation and vasoconstriction/dilation along with accurate determination of skin hydration through measurements of thermal conductivity represent some important operational examples.

  8. An intelligent stand-alone ultrasonic device for monitoring local structural damage: implementation and preliminary experiments

    International Nuclear Information System (INIS)

    Pertsch, Alexander; Kim, Jin-Yeon; Wang, Yang; Jacobs, Laurence J

    2011-01-01

    Continuous structural health monitoring has the potential to significantly improve the safety management of aged, in-service civil structures. In particular, monitoring of local damage growth at hot-spot areas can help to prevent disastrous structural failures. Although ultrasonic nondestructive evaluation (NDE) has proved to be effective in monitoring local damage growth, conventional equipment and devices are usually bulky and only suitable for scheduled human inspections. The objective of this research is to harness the latest developments in embedded hardware and wireless communication for developing a stand-alone, compact ultrasonic device. The device is directed at the continuous structural health monitoring of civil structures. Relying on battery power, the device possesses the functionalities of high-speed actuation, sensing, signal processing, and wireless communication. Integrated with contact ultrasonic transducers, the device can generate 1 MHz Rayleigh surface waves in a steel specimen and measure response waves. An envelope detection algorithm based on the Hilbert transform is presented for efficiently determining the peak values of the response signals, from which small surface cracks are successfully identified

  9. Low cost nuclear spectrometer based on micro-controller device

    International Nuclear Information System (INIS)

    Carrillo, M.A.; Aramayo, P.B.

    2009-01-01

    The present work describes the development of a gamma radiation Multichannel Analyzer device. That is to say, the development of a device able to display in the screen of a conventional computer a histogram of radioactive accounts (or accounts rate) received, in function of the different emission energies. It is a low cost implementation, oriented to mainly educational activities, but also applicable, within its limitations, to medium precision investigation works. In this first phase all the necessary one was implemented to detect the radioactive emissions, to measure them in energy, to store a complete spectrum and electronically to transfer it to a PC for its subsequent analysis. (author)

  10. Corporate Governance Scorecards : Assessing and Promoting the Implementation of Codes of Corporate Governance

    OpenAIRE

    International Finance Corporation

    2014-01-01

    This is a supplement to second IFC's toolkit: developing Corporate Governance codes of best practice. The focus of second toolkit is the development of codes of corporate governance. This supplement focuses narrowly on how to use scorecards to measure the observance and implementation of such codes. It does not cover the full panoply of governance assessment tools. This supplement provides...

  11. Assessing the Organizational Characteristics Influencing Quality Improvement Implementation in Saudi Hospitals.

    Science.gov (United States)

    Shamsuddin Alaraki, Mohammad

    The health care system in Saudi Arabia has serious problems with quality and safety that can be reduced through systematic quality improvement (QI) activities. Despite the use of different QI models to improve health care in Saudi hospitals during the last 2 decades, consistent improvements have not yet been achieved and the results are still far below expectations. This may reflect a problem in introducing and implementing the QI models in the local contexts. The objective of this study is to assess the extent of QI implementation in Saudi hospitals and to identify the organizational characteristics that make Saudi hospitals particularly challenging for QI. Understanding these characteristics can inform efforts to improve them and may lead to more successful implementation. A mixed-methods approach was conducted using 2 data collection tools: questionnaires and interviews. The quantitative phase (questionnaires) aimed to uncover the current level of QI implementation in Saudi hospital as measured by 7 critical dimensions adapted from the literature. The qualitative phase (interviews) aimed to understand the organizational characteristics that impede or underpin QI in Saudi hospitals. The QI implementation was found to be significantly poor across the 7 dimensions with average score ranging between 22.80 ± 0.57 and 2.11 ± 0.69 on a 5-point Likert scale and with P value of less than .05. We also found that the current level of QI implementation helped Saudi hospitals neither to improve "customer satisfaction" nor to achieve measurable improvements in "quality results" scoring significantly low at 2.11 ± 0.69 with P value of .000 and 2.47 ± 0.57 with P value of .000, respectively. Our study confirms the presence of a multitude of organizational barriers that impede QI in Saudi hospitals. These are related to organizational culture, human resources management, processes and systems, and structure. These 4 were found to have the strongest impact on QI in Saudi

  12. The iPad as an Instructional Tool: An Examination of Teacher Implementation Experiences

    Science.gov (United States)

    Benton, Brandie Kay

    2012-01-01

    At present, handheld devices and tablet computers are infiltrating public schools across the nation, the most popular model being the Apple iPad. Schools and teachers are attempting to integrate the devices and are using a variety of methods and models for implementation. The purpose of this study was to examine the implementation of the iPad as…

  13. Aperiodic nanoplasmonic devices for directional colour filtering and sensing.

    Science.gov (United States)

    Davis, Matthew S; Zhu, Wenqi; Xu, Ting; Lee, Jay K; Lezec, Henri J; Agrawal, Amit

    2017-11-07

    Exploiting the wave-nature of light in its simplest form, periodic architectures have enabled a panoply of tunable optical devices with the ability to perform useful functions such as filtering, spectroscopy, and multiplexing. Here, we remove the constraint of structural periodicity to enhance, simultaneously, the performance and functionality of passive plasmonic devices operating at optical frequencies. By using a physically intuitive, first-order interference model of plasmon-light interactions, we demonstrate a simple and efficient route towards designing devices with flexible, multi-spectral optical response, fundamentally not achievable using periodic architectures. Leveraging this approach, we experimentally implement ultra-compact directional light-filters and colour-sorters exhibiting angle- or spectrally-tunable optical responses with high contrast, and low spectral or spatial crosstalk. Expanding the potential of aperiodic systems to implement tailored spectral and angular responses, these results hint at promising applications in solar-energy harvesting, optical signal multiplexing, and integrated sensing.

  14. Overview of the OGAP Formative Assessment Project and CPRE's Large-Scale Experimental Study of Implementation and Impacts

    Science.gov (United States)

    Supovitz, Jonathan

    2016-01-01

    In this presentation discussed in this brief abstracted report, the author presents about an ongoing partnership with the Philadelphia School District (PSD) to implement and research the Ongoing Assessment Project (OGAP). OGAP is a systematic, intentional and iterative formative assessment system grounded in the research on how students learn…

  15. 75 FR 14510 - Implementation of Device Registration and Listing Requirements Enacted in the Public Health...

    Science.gov (United States)

    2010-03-26

    .... FOR FURTHER INFORMATION CONTACT: Theresa McDonald, Center for Devices and Radiological Health (HFZ-307... assigned HDE number for a device approved for marketing under section 520(m) of the FD&C Act. This proposal...

  16. Neuro-inspired computing using resistive synaptic devices

    CERN Document Server

    2017-01-01

    This book summarizes the recent breakthroughs in hardware implementation of neuro-inspired computing using resistive synaptic devices. The authors describe how two-terminal solid-state resistive memories can emulate synaptic weights in a neural network. Readers will benefit from state-of-the-art summaries of resistive synaptic devices, from the individual cell characteristics to the large-scale array integration. This book also discusses peripheral neuron circuits design challenges and design strategies. Finally, the authors describe the impact of device non-ideal properties (e.g. noise, variation, yield) and their impact on the learning performance at the system-level, using a device-algorithm co-design methodology. • Provides single-source reference to recent breakthroughs in resistive synaptic devices, not only at individual cell-level, but also at integrated array-level; • Includes detailed discussion of the peripheral circuits and array architecture design of the neuro-crossbar system; • Focuses on...

  17. Fibre optic communication key devices

    CERN Document Server

    Grote, Norbert

    2017-01-01

    The book gives an in-depth description of key devices of current and next generation fibre optic communication networks. Devices treated include semiconductor lasers, optical amplifiers, modulators, wavelength filters and other passives, detectors, all-optical switches, but relevant properties of optical fibres and network aspects are included as well. The presentations include the physical principles underlying the various devices, technologies used for their realization, typical performance characteristics and limitations, but development trends towards more advanced components are also illustrated. This new edition of a successful book was expanded and updated extensively. The new edition covers among others lasers for optical communication, optical switches, hybrid integration, monolithic integration and silicon photonics. The main focus is on Indium phosphide-based structures but silicon photonics is included as well. The book covers relevant principles, state-of-the-art implementations, status of curren...

  18. Toward biomaterial-based implantable photonic devices

    Directory of Open Access Journals (Sweden)

    Humar Matjaž

    2017-03-01

    Full Text Available Optical technologies are essential for the rapid and efficient delivery of health care to patients. Efforts have begun to implement these technologies in miniature devices that are implantable in patients for continuous or chronic uses. In this review, we discuss guidelines for biomaterials suitable for use in vivo. Basic optical functions such as focusing, reflection, and diffraction have been realized with biopolymers. Biocompatible optical fibers can deliver sensing or therapeutic-inducing light into tissues and enable optical communications with implanted photonic devices. Wirelessly powered, light-emitting diodes (LEDs and miniature lasers made of biocompatible materials may offer new approaches in optical sensing and therapy. Advances in biotechnologies, such as optogenetics, enable more sophisticated photonic devices with a high level of integration with neurological or physiological circuits. With further innovations and translational development, implantable photonic devices offer a pathway to improve health monitoring, diagnostics, and light-activated therapies.

  19. 76 FR 50230 - Center for Devices and Radiological Health 510(k) Clearance Process; Recommendations Proposed in...

    Science.gov (United States)

    2011-08-12

    ... develop and implement a program of continuous quality improvement to track regulatory decisions on medical devices, identify potential process improvements in the medical device regulatory framework, and address... software used in devices, software used as devices, and software used as a tool in producing devices. 8...

  20. Systematic Assessment of Neutron and Gamma Backgrounds Relevant to Operational Modeling and Detection Technology Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, Daniel E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hornback, Donald Eric [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Johnson, Jeffrey O. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nicholson, Andrew D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patton, Bruce W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Peplow, Douglas E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ayaz-Maierhafer, Birsen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This report summarizes the findings of a two year effort to systematically assess neutron and gamma backgrounds relevant to operational modeling and detection technology implementation. The first year effort focused on reviewing the origins of background sources and their impact on measured rates in operational scenarios of interest. The second year has focused on the assessment of detector and algorithm performance as they pertain to operational requirements against the various background sources and background levels.

  1. A RFID specific participatory design approach to support design and implementation of real-time location systems in the operating room.

    Science.gov (United States)

    Guédon, A C P; Wauben, L S G L; de Korne, D F; Overvelde, M; Dankelman, J; van den Dobbelsteen, J J

    2015-01-01

    Information technology, such as real-time location (RTL) systems using Radio Frequency IDentification (RFID) may contribute to overcome patient safety issues and high costs in healthcare. The aim of this work is to study if a RFID specific Participatory Design (PD) approach supports the design and the implementation of RTL systems in the Operating Room (OR). A RFID specific PD approach was used to design and implement two RFID based modules. The Device Module monitors the safety status of OR devices and the Patient Module tracks the patients' locations during their hospital stay. The PD principles 'multidisciplinary team', 'participation users (active involvement)' and 'early adopters' were used to include users from the RFID company, the university and the hospital. The design and implementation process consisted of two 'structured cycles' ('iterations'). The effectiveness of this approach was assessed by the acceptance in terms of level of use, continuity of the project and purchase. The Device Module included eight strategic and twelve tactical actions and the Patient Module included six strategic and twelve tactical actions. Both modules are now used on a daily basis and are purchased by the hospitals for continued use. The RFID specific PD approach was effective in guiding and supporting the design and implementation process of RFID technology in the OR. The multidisciplinary teams and their active participation provided insights in the social and the organizational context of the hospitals making it possible to better fit the technology to the hospitals' (future) needs.

  2. Exer-Genie(Registered Trademark) Exercise Device Hardware Evaluation

    Science.gov (United States)

    Schaffner, Grant; Sharp,Carwyn; Stroud, Leah

    2008-01-01

    An engineering evaluation was performed on the ExerGenie(r) exercise device to quantify its capabilities and limitations to address questions from the Constellation Program. Three subjects performed rowing and circuit training sessions to assess the suitability of the device for aerobic exercise. Three subjects performed a resistive exercise session to assess the suitability of the device for resistive exercise. Since 1 subject performed both aerobic and resistive exercise sessions, a total of 5 subjects participated.

  3. Implementation, reliability, and feasibility test of an Open-Source PACS.

    Science.gov (United States)

    Valeri, Gianluca; Zuccaccia, Matteo; Badaloni, Andrea; Ciriaci, Damiano; La Riccia, Luigi; Mazzoni, Giovanni; Maggi, Stefania; Giovagnoni, Andrea

    2015-12-01

    To implement a hardware and software system able to perform the major functions of an Open-Source PACS, and to analyze it in a simulated real-world environment. A small home network was implemented, and the Open-Source operating system Ubuntu 11.10 was installed in a laptop containing the Dcm4chee suite with the software devices needed. The Open-Source PACS implemented is compatible with Linux OS, Microsoft OS, and Mac OS X; furthermore, it was used with operating systems that guarantee the operation in portable devices (smartphone, tablet) Android and iOS. An OSS PACS is useful for making tutorials and workshops on post-processing techniques for educational and training purposes.

  4. A neural network device for on-line particle identification in cosmic ray experiments

    International Nuclear Information System (INIS)

    Scrimaglio, R.; Finetti, N.; D'Altorio, L.; Rantucci, E.; Raso, M.; Segreto, E.; Tassoni, A.; Cardarilli, G.C.

    2004-01-01

    On-line particle identification is one of the main goals of many experiments in space both for rare event studies and for optimizing measurements along the orbital trajectory. Neural networks can be a useful tool for signal processing and real time data analysis in such experiments. In this document we report on the performances of a programmable neural device which was developed in VLSI analog/digital technology. Neurons and synapses were accomplished by making use of Operational Transconductance Amplifier (OTA) structures. In this paper we report on the results of measurements performed in order to verify the agreement of the characteristic curves of each elementary cell with simulations and on the device performances obtained by implementing simple neural structures on the VLSI chip. A feed-forward neural network (Multi-Layer Perceptron, MLP) was implemented on the VLSI chip and trained to identify particles by processing the signals of two-dimensional position-sensitive Si detectors. The radiation monitoring device consisted of three double-sided silicon strip detectors. From the analysis of a set of simulated data it was found that the MLP implemented on the neural device gave results comparable with those obtained with the standard method of analysis confirming that the implemented neural network could be employed for real time particle identification

  5. FPGA-based implementation of sorting networks in MMC applications

    DEFF Research Database (Denmark)

    Ricco, Mattia; Máthé, Lászlo; Teodorescu, Remus

    2016-01-01

    , and they are usually implemented in microcontrollers or DSPs. However, they are not convenient for hardware implementation due to their inherent sequential operation. Instead, the proposed SNs, are suitable for FPGA devices thanks to their fixed parallel structure that allows improving the timing performance...

  6. Assessing the flexibility of research-based instructional strategies: Implementing tutorials in introductory physics in the lecture environment

    Science.gov (United States)

    Kryjevskaia, Mila; Boudreaux, Andrew; Heins, Dustin

    2014-03-01

    Materials from Tutorials in Introductory Physics, originally designed and implemented by the Physics Education Group at the University of Washington, were used in modified form as interactive lectures under conditions significantly different from those suggested by the curriculum developers. Student learning was assessed using tasks drawn from the physics education research literature. Use of tutorials in the interactive lecture format yielded gains in student understanding comparable to those obtained through the canonical tutorial implementation at the University of Washington, suggesting that student engagement with the intellectual steps laid out in the tutorials, rather than the specific strategies used in facilitating such engagement, plays the central role in promoting student learning. We describe the implementation details and assessment of student learning for two different tutorials: one focused on mechanical waves, used at North Dakota State University, and one on Galilean relativity, used at Western Washington University. Also discussed are factors that may limit the generalizability of the results.

  7. Implementation and Evaluation of Four Interoperable Open Standards for the Internet of Things

    Science.gov (United States)

    Jazayeri, Mohammad Ali; Liang, Steve H. L.; Huang, Chih-Yuan

    2015-01-01

    Recently, researchers are focusing on a new use of the Internet called the Internet of Things (IoT), in which enabled electronic devices can be remotely accessed over the Internet. As the realization of IoT concept is still in its early stages, manufacturers of Internet-connected devices and IoT web service providers are defining their proprietary protocols based on their targeted applications. Consequently, IoT becomes heterogeneous in terms of hardware capabilities and communication protocols. Addressing these heterogeneities by following open standards is a necessary step to communicate with various IoT devices. In this research, we assess the feasibility of applying existing open standards on resource-constrained IoT devices. The standard protocols developed in this research are OGC PUCK over Bluetooth, TinySOS, SOS over CoAP, and OGC SensorThings API. We believe that by hosting open standard protocols on IoT devices, not only do the devices become self-describable, self-contained, and interoperable, but innovative applications can also be easily developed with standardized interfaces. In addition, we use memory consumption, request message size, response message size, and response latency to benchmark the efficiency of the implemented protocols. In all, this research presents and evaluates standard-based solutions to better understand the feasibility of applying existing standards to the IoT vision. PMID:26402683

  8. Implementation and Evaluation of Four Interoperable Open Standards for the Internet of Things.

    Science.gov (United States)

    Jazayeri, Mohammad Ali; Liang, Steve H L; Huang, Chih-Yuan

    2015-09-22

    Recently, researchers are focusing on a new use of the Internet called the Internet of Things (IoT), in which enabled electronic devices can be remotely accessed over the Internet. As the realization of IoT concept is still in its early stages, manufacturers of Internet-connected devices and IoT web service providers are defining their proprietary protocols based on their targeted applications. Consequently, IoT becomes heterogeneous in terms of hardware capabilities and communication protocols. Addressing these heterogeneities by following open standards is a necessary step to communicate with various IoT devices. In this research, we assess the feasibility of applying existing open standards on resource-constrained IoT devices. The standard protocols developed in this research are OGC PUCK over Bluetooth, TinySOS, SOS over CoAP, and OGC SensorThings API. We believe that by hosting open standard protocols on IoT devices, not only do the devices become self-describable, self-contained, and interoperable, but innovative applications can also be easily developed with standardized interfaces. In addition, we use memory consumption, request message size, response message size, and response latency to benchmark the efficiency of the implemented protocols. In all, this research presents and evaluates standard-based solutions to better understand the feasibility of applying existing standards to the IoT vision.

  9. [The implementation of the week surgery in an orthopedic and urology ward and assessment of its impact].

    Science.gov (United States)

    Mulloni, Giovanna; Petrucco, Stefania; De Marc, Raffaella; Nazzi, Cheti; Petri, Roberto; Guarrera, Giovanni Maria

    2015-01-01

    The implementation of the week surgery in an orthopedic and urology ward and the assessment of its impact. The week surgery (WS) is one of the models organized according the intensity of care that allows the improvement of the appropriateness of the hospital admissions. To describe the implementation and the impact of the WS on costs and levels of care. The WS was gradually implemented in an orthopedic and urology ward. The planning of the surgeries was modified, the wards where patients would have been transferred during the week-end where identified, the nurses were supported by expert nurses to learn new skills and clinical pathways were implemented. The periods January-June 2012 and 2013 were compared identifying a set of indicators according to the health technology assessment method. The nurses were able to take vacations according to schedule; the cost of outsourcing services were reduced (-4.953 Euros) as well as those of consumables. The nursing care could be guaranteed employing less (-5) full-time nurses; the global clinical performance of the ward did not vary. Unfortunately several urology patients could not be discharged during the week-ends. A good planning of the surgeries according to the patients' length of staying, together with interventions to increase the staff-skill mix, and the clinical pathways allowed an effective and efficient implementation of the WS model without jeopardizing patients' safety.

  10. Basic simulation models of phase tracking devices using Matlab

    CERN Document Server

    Tranter, William

    2010-01-01

    The Phase-Locked Loop (PLL), and many of the devices used for frequency and phase tracking, carrier and symbol synchronization, demodulation, and frequency synthesis, are fundamental building blocks in today's complex communications systems. It is therefore essential for both students and practicing communications engineers interested in the design and implementation of modern communication systems to understand and have insight into the behavior of these important and ubiquitous devices. Since the PLL behaves as a nonlinear device (at least during acquisition), computer simulation can be used

  11. Increasing physical activity with mobile devices: a meta-analysis.

    Science.gov (United States)

    Fanning, Jason; Mullen, Sean P; McAuley, Edward

    2012-11-21

    Regular physical activity has established physical and mental health benefits; however, merely one quarter of the U.S. adult population meets national physical activity recommendations. In an effort to engage individuals who do not meet these guidelines, researchers have utilized popular emerging technologies, including mobile devices (ie, personal digital assistants [PDAs], mobile phones). This study is the first to synthesize current research focused on the use of mobile devices for increasing physical activity. To conduct a meta-analysis of research utilizing mobile devices to influence physical activity behavior. The aims of this review were to: (1) examine the efficacy of mobile devices in the physical activity setting, (2) explore and discuss implementation of device features across studies, and (3) make recommendations for future intervention development. We searched electronic databases (PubMed, PsychINFO, SCOPUS) and identified publications through reference lists and requests to experts in the field of mobile health. Studies were included that provided original data and aimed to influence physical activity through dissemination or collection of intervention materials with a mobile device. Data were extracted to calculate effect sizes for individual studies, as were study descriptives. A random effects meta-analysis was conducted using the Comprehensive Meta-Analysis software suite. Study quality was assessed using the quality of execution portion of the Guide to Community Preventative Services data extraction form. Four studies were of "good" quality and seven of "fair" quality. In total, 1351 individuals participated in 11 unique studies from which 18 effects were extracted and synthesized, yielding an overall weight mean effect size of g = 0.54 (95% CI = 0.17 to 0.91, P = .01). Research utilizing mobile devices is gaining in popularity, and this study suggests that this platform is an effective means for influencing physical activity behavior. Our focus

  12. Noninvasive Dry Eye Assessment Using High-Technology Ophthalmic Examination Devices.

    Science.gov (United States)

    Yamaguchi, Masahiko; Sakane, Yuri; Kamao, Tomoyuki; Zheng, Xiaodong; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-11-01

    Recently, the number of dry eye cases has dramatically increased. Thus, it is important that easy screening, exact diagnoses, and suitable treatments be available. We developed 3 original and noninvasive assessments for this disorder. First, a DR-1 dry eye monitor was used to determine the tear meniscus height quantitatively by capturing a tear meniscus digital image that was analyzed by Meniscus Processor software. The DR-1 meniscus height value significantly correlated with the fluorescein meniscus height (r = 0.06, Bland-Altman analysis). At a cutoff value of 0.22 mm, sensitivity of the dry eye diagnosis was 84.1% with 90.9% specificity. Second, the Tear Stability Analysis System was used to quantitatively measure tear film stability using a topographic modeling system corneal shape analysis device. Tear film stability was objectively and quantitatively evaluated every second during sustained eye openings. The Tear Stability Analysis System is currently installed in an RT-7000 autorefractometer and topographer to automate the diagnosis of dry eye. Third, the Ocular Surface Thermographer uses ophthalmic thermography for diagnosis. The decrease in ocular surface temperature in dry eyes was significantly greater than that in normal eyes (P eye opening. Decreased corneal temperature correlated significantly with the tear film breakup time (r = 0.572; P dry eye, sensitivity was 0.83 and specificity was 0.80 after 10 seconds. This article describes the details and potential of these 3 noninvasive dry eye assessment systems.

  13. A Critical Assessment on SPC Implementation in the UK Food Industry

    Directory of Open Access Journals (Sweden)

    Sarina Abdul Halim Lim

    2016-02-01

    Full Text Available Statistical process control (SPC is one of the most widely applied techniques to control and improve processes in manufacturing industry, but very few studies have reported on the successful application of SPC in the food industry. This paper aims to critically assess the status of SPC in the UK food manufacturing industry and suggests avenues for future research. By surveying the UK food-manufacturing companies, forty-five percent of them were identified implemented SPC, with x-R and x-S charts found to be the most commonly applied SPC charts in this industry. Top management commitment was identified as the most critical factor, while lack of SPC training is the most significant challenge and lack of awareness of SPC as the main reason for food manufacturing companies not implementing SPC. The paper provides information to food companies in the UK on most common practiced and useful quality tools, SPC charts and critical success factors in the food industry. Furthermore, based on the process performance parameters, SPC companies were observed to achieving better results compared to non-SPC companies.

  14. Electronic polymer memory devices-Easy to fabricate, difficult to understand

    International Nuclear Information System (INIS)

    Paul, Shashi; Salaoru, Iulia

    2010-01-01

    There has been a number reports on polymer memory devices for the last one decade. Polymer memory devices are fabricated by depositing a blend (an admixture of organic polymer, small organic molecules and nanoparticles) between two metal electrodes. These devices show two electrical conductance states ('1' and '0') when voltage is applied, thus rendering the structures suitable for data retention. These two states can be viewed as the realisation of memory devices. However, polymer memory devices reported so far suffer from multiple drawbacks that render their industrial implementation premature. There is a large discrepancy in the results reported by different groups. This article attempts to answer some of the questions.

  15. Virtual Reality Interaction Using Mobile Devices

    KAUST Repository

    Aseeri, Sahar A.

    2013-07-01

    With the use of an immersive display system such as CAVE system, the user is able to realize a 3D immersive virtual environment realistically. However, interacting with virtual worlds in CAVE systems using traditional input devices to perform easy operations such as manipulation, object selection, and navigation is often difficult. This difficulty could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. Our research aims to implement and evaluate alternative approaches of interaction with immersive virtual environments on mobile devices for manipulation and object selection tasks. As many researchers have noted, using a mobile device as an interaction device has a number of advantages, including built-in display, built-in control, and touch screen facility. These advantages facilitate simple tasks within immersive virtual environments. This research proposes new methods using mobile devices like Smart-phones to perform di↵erent kinds of interactions both as an input device, (e.g. performing selection and manipulation of objects) and as an output device (e.g. utilizing the screen as an extra view for a virtual camera or information display). Moreover, we developed a prototype system to demonstrate and informally evaluate these methods. The research conclusion suggests using mobile devices as a 3D-controller. This will be a more intuitive approach to interact within the virtual environment.

  16. Implementation of life cycle impact assessment methods. Data v2.0 (2007). Ecoinvent report No. 3

    International Nuclear Information System (INIS)

    Frischknecht, R.; Jungbluth, N.; Althaus, H.-J.; Hischier, R.; Doka, G.; Bauer, Ch.; Dones, R.; Nemecek, T.; Hellweg, S.; Humbert, S.; Margni, M.; Koellner, T.; Loerincik, Y.

    2007-12-01

    The ecoinvent database offers life cycle inventory (LCI) and life cycle impact assessment (LCIA) results. The following LCIA methods are implemented in the ecoinvent data v2.0: CML 2001; Cumulative energy demand; Cumulative exergy demand; Eco-indicator 99; Ecological footprint; Ecological scarcity 1997; Ecosystem damage potential EDP; EDIP'97 and 2003 (Environmental design of industrial products); EPS 2000 (environmental priority strategies in product development (will be provided with ecoinvent data v2.1)); IMPACT 2002+; IPCC 2001 (climate change); TRACI; Selected life cycle inventory indicators. There is a range of methodological problems and questions while linking the LCIA methods with the elementary flows of a database. This lead to different results in the past, even if the same LCIA method was applied on the same inventory results. The aim of this report is to avoid such discrepancies. In the first part of this report the general assumptions for the implementation of impact assessment methods on the ecoinvent life cycle inventory data are described. For that purpose, general and harmonised rules were developed how to deal with a certain problem. The second part of this report contains a detailed description of the implementation of the above mentioned methods. Please refer to the original publications for a general description and the scientific background of the methods. It is strongly recommended to read the original publications before using the LCIA results from the ecoinvent database. It is recommended to follow these implementation guidelines also while using other or new LCIA methods, which are so far not implemented in ecoinvent data. (authors)

  17. Implementation of life cycle impact assessment methods. Data v2.0 (2007). Ecoinvent report No. 3

    Energy Technology Data Exchange (ETDEWEB)

    Frischknecht, R. (ed.) [Ecoinvent Centre, Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Jungbluth, N. (ed.) [ESU-services Ltd, Uster (Switzerland); Althaus, H.-J.; Hischier, R. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Doka, G. [Doka Life Cycle Assessments (LCA), Zuerich (Switzerland); Bauer, Ch.; Dones, R. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Nemecek, T. [Forschungsanstalt Agroscope Reckenholz-Taenikon (ART), Zuerich (Switzerland); Hellweg, S. [Swiss Federal Institute of Technology (ETHZ), Institute for Chemicals and Bioengineering (ICB), Zuerich (Switzerland); Humbert, S.; Margni, M. [Swiss Federal Institute of Technology (EPFL), Lausanne (Switzerland); Koellner, T. [Swiss Federal Institute of Technology (ETHZ), Zuerich (Switzerland); Loerincik, Y. [Ecointesys, Swiss Federal Institute of Technology (EPFL), Lausanne (Switzerland)

    2007-12-15

    The ecoinvent database offers life cycle inventory (LCI) and life cycle impact assessment (LCIA) results. The following LCIA methods are implemented in the ecoinvent data v2.0: CML 2001; Cumulative energy demand; Cumulative exergy demand; Eco-indicator 99; Ecological footprint; Ecological scarcity 1997; Ecosystem damage potential EDP; EDIP'97 and 2003 (Environmental design of industrial products); EPS 2000 (environmental priority strategies in product development (will be provided with ecoinvent data v2.1)); IMPACT 2002+; IPCC 2001 (climate change); TRACI; Selected life cycle inventory indicators. There is a range of methodological problems and questions while linking the LCIA methods with the elementary flows of a database. This lead to different results in the past, even if the same LCIA method was applied on the same inventory results. The aim of this report is to avoid such discrepancies. In the first part of this report the general assumptions for the implementation of impact assessment methods on the ecoinvent life cycle inventory data are described. For that purpose, general and harmonised rules were developed how to deal with a certain problem. The second part of this report contains a detailed description of the implementation of the above mentioned methods. Please refer to the original publications for a general description and the scientific background of the methods. It is strongly recommended to read the original publications before using the LCIA results from the ecoinvent database. It is recommended to follow these implementation guidelines also while using other or new LCIA methods, which are so far not implemented in ecoinvent data. (authors)

  18. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  19. Analyzing the Issues in the Implementation of Authentic Assessment in the 2013 Curriculum

    Directory of Open Access Journals (Sweden)

    Abna Hidayati

    2017-02-01

    Full Text Available The  implemention of authentic assessment  in the   2013 Ccurriculum  has been encountered by various challenges. Teacher have to use numerious instruments, which made them quite which are regarded more complicated. this study focused on the analysis of issues experienced by teachers in implementingng theauthentic assessment within the 2013 curriculum. This study used quantitatif method in which questionnaire was  distributed to the teachers. Population included all teachers in Padang whose schools are applying the 2013 curriculum. 120 teacher were randomly taken as the sample.  The results show that in terms of the affective aspect, the teachers had not yet been optimal in conducting self- and peer assessment for the students, thus the further improvement is seriously recomended. In light of the the cognitive aspect, the teachers had done a very good assessment. They had made a variety of assessment types, especially in the essay and oral tests. However, the assessment of psychomotor aspect was not also optimally done need some improvement. From these results, it is hoped that the teachers can further enhance the assessment procedures of the three criteria for better learning outcomes. The school principals should be able to create opportunities for the teachers to take training in the Applying authentic assessment.

  20. Balancing Tensions in Educational Policy Reforms: Large-Scale Implementation of Assessment for Learning in Norway

    Science.gov (United States)

    Hopfenbeck, Therese N.; Flórez Petour, María Teresa; Tolo, Astrid

    2015-01-01

    This study investigates how different stakeholders in Norway experienced a government-initiated, large-scale policy implementation programme on "Assessment for Learning" ("AfL"). Data were collected through 58 interviews with stakeholders in charge of the policy; Ministers of Education and members of the Directorate of…

  1. Implementing the Stochastic Model of Safety Assessment for the T.D.P. Plume Model

    International Nuclear Information System (INIS)

    Hurtado, A.; Eguilior, S.; Recreo, F.

    2015-01-01

    In this paper, it is continued with the first phase of the implementation of the ABACO2G methodology (Application of Bayes to CO2 Geological Storage ) which is a new methodological approach to solving the problem related with the determination of probabilistic component of CO2 geological storage risk assessment, through the application of Bayesian networks and MonteCarlo probability. This in itself is a fundalmental but complex task, inasmuch as the risk assessment requires the identification of those system performance influence variables and the probability distribution of occurrence of defined events, which is highly difficult when there is no significant casuistry and/or fully developed events. On this, at this stage it has been studied the CO2 plume stochastic evolution implementation during the injection period. This is an essential task because the CO2 geologic storage risks will rely primarily on the convolution of the CO2 plume wavefront probability function with the probability functions of system risk elements, such as wells or faults, that define the event space to estimate the CO2 geologic storage risks.

  2. Surface Acoustic Wave Devices for Harsh Environment Wireless Sensing

    Directory of Open Access Journals (Sweden)

    David W. Greve

    2013-05-01

    Full Text Available Langasite surface acoustic wave devices can be used to implement harsh-environment wireless sensing of gas concentration and temperature. This paper reviews prior work on the development of langasite surface acoustic wave devices, followed by a report of recent progress toward the implementation of oxygen gas sensors. Resistive metal oxide films can be used as the oxygen sensing film, although development of an adherent barrier layer will be necessary with the sensing layers studied here to prevent interaction with the langasite substrate. Experimental results are presented for the performance of a langasite surface acoustic wave oxygen sensor with tin oxide sensing layer, and these experimental results are correlated with direct measurements of the sensing layer resistivity.

  3. Exploring the impact of an automated prescription-filling device on community pharmacy technician workflow

    Science.gov (United States)

    Walsh, Kristin E.; Chui, Michelle Anne; Kieser, Mara A.; Williams, Staci M.; Sutter, Susan L.; Sutter, John G.

    2012-01-01

    Objective To explore community pharmacy technician workflow change after implementation of an automated robotic prescription-filling device. Methods At an independent community pharmacy in rural Mayville, WI, pharmacy technicians were observed before and 3 months after installation of an automated robotic prescription-filling device. The main outcome measures were sequences and timing of technician workflow steps, workflow interruptions, automation surprises, and workarounds. Results Of the 77 and 80 observations made before and 3 months after robot installation, respectively, 17 different workflow sequences were observed before installation and 38 after installation. Average prescription filling time was reduced by 40 seconds per prescription with use of the robot. Workflow interruptions per observation increased from 1.49 to 1.79 (P = 0.11), and workarounds increased from 10% to 36% after robot use. Conclusion Although automated prescription-filling devices can increase efficiency, workflow interruptions and workarounds may negate that efficiency. Assessing changes in workflow and sequencing of tasks that may result from the use of automation can help uncover opportunities for workflow policy and procedure redesign. PMID:21896459

  4. Data collected on TPAD implementation projects.

    Science.gov (United States)

    2014-11-01

    TPAD testing was conducted by CTR personnel at the following locations during TxDOT Project : 5-6005-01: Statewide Implementation of Total Pavement Acceptance Device (TPAD) (January : 2013 through August 2014): : (1) San Marcos Airport, : (2) IH 10 i...

  5. Implementation of the safety assessment in the practice of industrial radiography

    International Nuclear Information System (INIS)

    Alfonso Pallarés, C.; Pérez Reyes, Y.

    2015-01-01

    The CNSN as regulatory authority has regulatory control processes based on regulations, permits, inspections and limitation to ensure the supervision and control of the practice of industrial radiography. On the other hand in the light of the new regulations approved and being implemented such as: Resolution 334/2011 CITMA 'Regulation on Notification and authorization of practices and activities associated with the use of ionizing radiation sources' and Resolution 17 / 2012, Security Guide: Security Assessment Practices and Activities associated with the use of ionizing radiation (recommendatory), it is necessary for compliance with regulatory requirements concerning the safety assessment. Since 2009 it has been applied this experience in different medical practices and industry, providing a systematic and consistent basis, to the safety assessment of all facilities and activities, which has helped increase the confidence that has been achieved an adequate level of security. The work was able to identify that there is a group of barriers operating in the risk reduction in various accident sequences and therefore have a relative importance in risk reduction, recommendations in this regard to improve the program management of safety in the practice of industrial radiography. [es

  6. Instructions included? Make safety training part of medical device procurement process.

    Science.gov (United States)

    Keller, James P

    2010-04-01

    Before hospitals embrace new technologies, it's important that medical personnel agree on how best to use them. Likewise, hospitals must provide the support to operate these sophisticated devices safely. With this in mind, it's wise for hospitals to include medical device training in the procurement process. Moreover, purchasing professionals can play a key role in helping to increase the amount of user training for medical devices and systems. What steps should you take to help ensure that new medical devices are implemented safely? Here are some tips.

  7. Predicting Teachers' Intentions to Implement School-Based Assessment Using the Theory of Planned Behaviour

    Science.gov (United States)

    Yan, Zi

    2014-01-01

    The theory of planned behaviour (TPB) was used to explore the Hong Kong teachers' intentions to implement school-based assessment (SBA) and the predictors of those intentions. A total of 280 teachers from Hong Kong secondary schools who had been involved in SBA were surveyed. Rasch-calibrated teacher measures were calculated for each of the 6…

  8. Dynamic Observation of Brain-Like Learning in a Ferroelectric Synapse Device

    Science.gov (United States)

    Nishitani, Yu; Kaneko, Yukihiro; Ueda, Michihito; Fujii, Eiji; Tsujimura, Ayumu

    2013-04-01

    A brain-like learning function was implemented in an electronic synapse device using a ferroelectric-gate field effect transistor (FeFET). The FeFET was a bottom-gate type FET with a ZnO channel and a ferroelectric Pb(Zr,Ti)O3 (PZT) gate insulator. The synaptic weight, which is represented by the channel conductance of the FeFET, is updated by applying a gate voltage through a change in the ferroelectric polarization in the PZT. A learning function based on the symmetric spike-timing dependent synaptic plasticity was implemented in the synapse device using the multilevel weight update by applying a pulse gate voltage. The dynamic weighting and learning behavior in the synapse device was observed as a change in the membrane potential in a spiking neuron circuit.

  9. Unauthorized Data Theft from Bluetooth-Enabled Devices Using RFCOMMVulnerabilities

    Directory of Open Access Journals (Sweden)

    A. G. Beltov

    2012-09-01

    Full Text Available The article is dedicated to the attacks on Bluetooth devices. The described attacks allow hackers to steal private data from mobile devices. The attack is based on vulnerabilities found in RFCOMM-level of Bluetooth protocols stack. The described attack is even more dangerous because of the fact that a hacker can also implement any AT-command on the attacked mobile phone.

  10. Measurement-Device-Independent Quantum Cryptography

    Science.gov (United States)

    Tang, Zhiyuan

    Quantum key distribution (QKD) enables two legitimate parties to share a secret key even in the presence of an eavesdropper. The unconditional security of QKD is based on the fundamental laws of quantum physics. Original security proofs of QKD are based on a few assumptions, e.g., perfect single photon sources and perfect single-photon detectors. However, practical implementations of QKD systems do not fully comply with such assumptions due to technical limitations. The gap between theory and implementations leads to security loopholes in most QKD systems, and several attacks have been launched on sophisticated QKD systems. Particularly, the detectors have been found to be the most vulnerable part of QKD. Much effort has been put to build side-channel-free QKD systems. Solutions such as security patches and device-independent QKD have been proposed. However, the former are normally ad-hoc, and cannot close unidentified loopholes. The latter, while having the advantages of removing all assumptions on devices, is impractical to implement today. Measurement-device-independent QKD (MDI-QKD) turns out to be a promising solution to the security problem of QKD. In MDI-QKD, all security loopholes, including those yet-to-be discovered, have been removed from the detectors, the most critical part in QKD. In this thesis, we investigate issues related to the practical implementation and security of MDI-QKD. We first present a demonstration of polarization-encoding MDI-QKD. Taking finite key effect into account, we achieve a secret key rate of 0.005 bit per second (bps) over 10 km spooled telecom fiber, and a 1600-bit key is distributed. This work, together with other demonstrations, shows the practicality of MDI-QKD. Next we investigate a critical assumption of MDI-QKD: perfect state preparation. We apply the loss-tolerant QKD protocol and adapt it to MDI-QKD to quantify information leakage due to imperfect state preparation. We then present an experimental demonstration of

  11. FUNDAMENTALS OF STRUCTURAL TYPOLOGY DEVICE DESIGN WITH A GAS BEARING LAYER

    Directory of Open Access Journals (Sweden)

    I. A. Аvtsinоv

    2015-01-01

    Full Text Available We describe the typical stages of a structural typology of devices allowing them to design quality in the automatic mode on the known parameters of products (parts and the required processing operations with them. In the first stage classification it was organized as a piece of specific products and devices for the manipulation of the latter. Specifics items described their physical – mechanical properties, geometry and their application. The most frequently described specific products are used in pharmaceutical, perfume, food, microelectronics, electrical engineering, electronics. The main elements of the proposed device is a carrier working surface over which a thin layer of gas is created. Depending on the position (horizontal or vertical of the form of its movement (rotation, rotational – translational or is stationary, and the configuration of the carrier operating the surface implement various manufacturing operations (targeting, positioning, shaping, classification, transport, heat treatment, weight control, assembly, culling, and others. The second stage was to mathematically describe the relationship of the specificity of piece goods, with design features of devices supporting the work surface and sold them operations. For this purpose, the device has been used in discrete mathematics, with which you can produce a description of all types of devices, and then make a conclusion such as the work surface meets the specified requirements. The apparent advantage of using predicate logic to this problem is fairly simple implementation of the algorithm of structural typology, which can be expressed using a declarative programming language. In the third phase, work is underway to create the necessary algorithmic language program "Prolog" and presented the structure of the imperative and declarative implementation of the algorithm.

  12. DEVICES FOR COOLING ELECTRONIC CIRCUIT BOARDS

    OpenAIRE

    T. A. Ismailov; D. V. Evdulov; A. G. Mustafaev; D. K. Ramazanova

    2014-01-01

    In the work described structural variants of devices for cooling electronic circuit boards, made on the basis of thermoelectric batteries and consumable working substances, implementing uneven process of removing heat from heat-generating components. A comparison of temperature fields of electronic circuit simulator with his uniform and non-uniform cooling. 

  13. Implementation of computerized physician order entry in National Guard Hospitals: assessment of critical success factors.

    Science.gov (United States)

    Altuwaijri, Majid M; Bahanshal, Abdullah; Almehaid, Mona

    2011-09-01

    The purpose of this study is to describe the needs, process and experience of implementing a computerized physician order entry (CPOE) system in a leading healthcare organization in Saudi Arabia. The National Guard Health Affairs (NGHA) deployed the CPOE in a pilot department, which was the intensive care unit (ICU) in order to assess its benefits and risks and to test the system. After the CPOE was implemented in the ICU area, a survey was sent to the ICU clinicians to assess their perception on the importance of 32 critical success factors (CSFs) that was acquired from the literature. The project team also had several meetings to gather lessons learned from the pilot project in order to utilize them for the expansion of the project to other NGHA clinics and hospitals. The results of the survey indicated that the selected CSFs, even though they were developed with regard to international settings, are very much applicable for the pilot area. The top three CSFs rated by the survey respondents were: The "before go-live training", the adequate clinical resources during implementation, and the ordering time. After the assessment of the survey and the lessons learned from the pilot project, NGHA decided that the potential benefits of the CPOE are expected to be greater the risks expected. The project was then expanded to cover all NGHA clinics and hospitals in a phased approach. Currently, the project is in its final stages and expected to be completed by the end of 2011. The role of CPOE systems is very important in hospitals in order to reduce medication errors and to improve the quality of care. In spite of their great benefits, many studies suggest that a high percentage of these projects fail. In order to increase the chances of success and due to the fact that CPOE is a clinical system, NGHA implemented the system first in a pilot area in order to test the system without putting patients at risk and to learn from mistakes before expanding the system to other

  14. Implementation of computerized physician order entry in National Guard hospitals: Assessment of critical success factors

    Directory of Open Access Journals (Sweden)

    Majid M Altuwaijri

    2011-01-01

    Full Text Available Objective: The purpose of this study is to describe the needs, process and experience of implementing a computerized physician order entry (CPOE system in a leading healthcare organization in Saudi Arabia. Materials and Methods: The National Guard Health Affairs (NGHA deployed the CPOE in a pilot department, which was the intensive care unit (ICU in order to assess its benefits and risks and to test the system. After the CPOE was implemented in the ICU area, a survey was sent to the ICU clinicians to assess their perception on the importance of 32 critical success factors (CSFs that was acquired from the literature. The project team also had several meetings to gather lessons learned from the pilot project in order to utilize them for the expansion of the project to other NGHA clinics and hospitals. Results: The results of the survey indicated that the selected CSFs, even though they were developed with regard to international settings, are very much applicable for the pilot area. The top three CSFs rated by the survey respondents were: The "before go-live" training, the adequate clinical resources during implementation, and the ordering time. After the assessment of the survey and the lessons learned from the pilot project, NGHA decided that the potential benefits of the CPOE are expected to be greater the risks expected. The project was then expanded to cover all NGHA clinics and hospitals in a phased approach. Currently, the project is in its final stages and expected to be completed by the end of 2011. Conclusion: The role of CPOE systems is very important in hospitals in order to reduce medication errors and to improve the quality of care. In spite of their great benefits, many studies suggest that a high percentage of these projects fail. In order to increase the chances of success and due to the fact that CPOE is a clinical system, NGHA implemented the system first in a pilot area in order to test the system without putting patients at

  15. Experience in the implementation of quality assurance program and safety culture assessment of research reactor operation and maintenance

    International Nuclear Information System (INIS)

    Syarip; Suryopratomo, K.

    2001-01-01

    The implementation of quality assurance program and safety culture for research reactor operation are of importance to assure its safety status. It comprises an assessment of the quality of both technical and organizational aspects involved in safety. The method for the assessment is based on judging the quality of fulfillment of a number of essential issues for safety i.e. through audit, interview and/or discussions with personnel and management in plant. However, special consideration should be given to the data processing regarding the fuzzy nature of the data i.e. in answering the questionnaire. To accommodate this situation, the SCAP, a computer program based on fuzzy logic for assessing plant safety status, has been developed. As a case study, the experience in the assessment of Kartini research reactor safety status shows that it is strongly related to the implementation of quality assurance program in reactor operation and awareness of reactor operation staffs to safety culture practice. It is also shown that the application of the fuzzy rule in assessing reactor safety status gives a more realistic result than the traditional approach. (author)

  16. Classroom Implementation. Issues in Assessment.

    Science.gov (United States)

    Malinowski, Patricia A., Ed.

    This booklet, second in a series on issues in assessment, seeks to describe an initiative supported by Finger Lakes Community College (New York) to use classroom assessment techniques (CATs) in different academic areas and to present an overview of some assessment approaches that have been used in the classroom. Papers include: (1) "Enhancing…

  17. Quantum computers: Definition and implementations

    International Nuclear Information System (INIS)

    Perez-Delgado, Carlos A.; Kok, Pieter

    2011-01-01

    The DiVincenzo criteria for implementing a quantum computer have been seminal in focusing both experimental and theoretical research in quantum-information processing. These criteria were formulated specifically for the circuit model of quantum computing. However, several new models for quantum computing (paradigms) have been proposed that do not seem to fit the criteria well. Therefore, the question is what are the general criteria for implementing quantum computers. To this end, a formal operational definition of a quantum computer is introduced. It is then shown that, according to this definition, a device is a quantum computer if it obeys the following criteria: Any quantum computer must consist of a quantum memory, with an additional structure that (1) facilitates a controlled quantum evolution of the quantum memory; (2) includes a method for information theoretic cooling of the memory; and (3) provides a readout mechanism for subsets of the quantum memory. The criteria are met when the device is scalable and operates fault tolerantly. We discuss various existing quantum computing paradigms and how they fit within this framework. Finally, we present a decision tree for selecting an avenue toward building a quantum computer. This is intended to help experimentalists determine the most natural paradigm given a particular physical implementation.

  18. Health technology assessment process of a cardiovascular medical device in four different settings.

    Science.gov (United States)

    Olry de Labry Lima, Antonio; Espín Balbino, Jaime; Lemgruber, Alexandre; Caro Martínez, Araceli; García-Mochón, Leticia; Martín Ruiz, Eva; Lessa, Fernanda

    2017-10-01

    Health technology assessment (HTA) is a tool to help the decision-making process. The aim is to describe methods and processes used in the reimbursement decision making for drug-eluting stents (DES) in four different settings. DES as a technology under study was selected according to different criteria, all of them agreed by a working group. A survey of key informants was designed. DES was evaluated following well-structured HTA processes. Nonetheless, scope for improvement was observed in relation to the data considered for the final decision, the transparency and inclusiveness of the process as well as in the methods employed. An attempt to describe the HTA processes of a well-known medical device.

  19. Research on seal control systems for international nuclear safeguard and the vulnerability assessment on the seals

    International Nuclear Information System (INIS)

    Zhang Hongjian; Liu Tianshu; Cao Fangfang; Xu Chunyan

    2014-01-01

    Safeguard seals, also called Tamper-indicating devices (TIDs), are widely used to detect tampering or unauthorized entry in the international safeguard and security systems, Seal control systems consist of seal implementing plan, seal development and the vulnerability assessment on tbe seals, effective implementing procedures and methods of the seals. The vulnerability assessment contents of safeguard seals, thermo-shrinked film seals being as an example, and seals control systems in the implementation program are researched. The seal control systems discuss task assignment, seals management flow and seals program data flow to promote applying effectively seals. The vulnerability assessment program of seals studies assurance level to some different tampering techniques and measures. The researches must promote utilizing seals effectively for nuclear security, non-proliferation of nuclear weapons, radioactive waste management, and the nuclear material accounting and control. (authors)

  20. Hardware realization of an SVM algorithm implemented in FPGAs

    Science.gov (United States)

    Wiśniewski, Remigiusz; Bazydło, Grzegorz; Szcześniak, Paweł

    2017-08-01

    The paper proposes a technique of hardware realization of a space vector modulation (SVM) of state function switching in matrix converter (MC), oriented on the implementation in a single field programmable gate array (FPGA). In MC the SVM method is based on the instantaneous space-vector representation of input currents and output voltages. The traditional computation algorithms usually involve digital signal processors (DSPs) which consumes the large number of power transistors (18 transistors and 18 independent PWM outputs) and "non-standard positions of control pulses" during the switching sequence. Recently, hardware implementations become popular since computed operations may be executed much faster and efficient due to nature of the digital devices (especially concurrency). In the paper, we propose a hardware algorithm of SVM computation. In opposite to the existing techniques, the presented solution applies COordinate Rotation DIgital Computer (CORDIC) method to solve the trigonometric operations. Furthermore, adequate arithmetic modules (that is, sub-devices) used for intermediate calculations, such as code converters or proper sectors selectors (for output voltages and input current) are presented in detail. The proposed technique has been implemented as a design described with the use of Verilog hardware description language. The preliminary results of logic implementation oriented on the Xilinx FPGA (particularly, low-cost device from Artix-7 family from Xilinx was used) are also presented.

  1. Computer simulation and implementation of defected ground structure on a microstrip antenna

    Science.gov (United States)

    Adrian, H.; Rambe, A. H.; Suherman

    2018-03-01

    Defected Ground Structure (DGS) is a method reducing etching area on antenna ground to form desirable antenna’s ground field. This paper reports the method impact on microstrip antennas working on 1800 and 2400 MHz. These frequencies are important as many radio network applications such mobile phones and wireless devices working on these channels. The assessments were performed by simulating and fabricating the evaluated antennas. Both simulation data and implementation measurements show that DGS successfully improves antenna performances by increasing bandwidth up to 19%, reducing return loss up to 109% and increasing gain up to 33%.

  2. 3D-printed Bioanalytical Devices

    Science.gov (United States)

    Bishop, Gregory W; Satterwhite-Warden, Jennifer E; Kadimisetty, Karteek; Rusling, James F

    2016-01-01

    While 3D printing technologies first appeared in the 1980s, prohibitive costs, limited materials, and the relatively small number of commercially available printers confined applications mainly to prototyping for manufacturing purposes. As technologies, printer cost, materials, and accessibility continue to improve, 3D printing has found widespread implementation in research and development in many disciplines due to ease-of-use and relatively fast design-to-object workflow. Several 3D printing techniques have been used to prepare devices such as milli- and microfluidic flow cells for analyses of cells and biomolecules as well as interfaces that enable bioanalytical measurements using cellphones. This review focuses on preparation and applications of 3D-printed bioanalytical devices. PMID:27250897

  3. The development and validation of a custom built device for assessing frontal knee joint laxity.

    Science.gov (United States)

    Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos

    2017-12-01

    This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The Role of Device Diagnostic Algorithms in the Assessment and Management of Patients with Systolic Heart Failure: A Review

    Directory of Open Access Journals (Sweden)

    Andrew C. T. Ha

    2011-01-01

    Full Text Available Hospitalization due to heart failure (HF exacerbation represents a major burden in health care and portends a poor long-term prognosis for patients. As a result, there is considerable interest to develop novel tools and strategies to better detect onset of volume overload, as HF hospitalizations may be reduced if appropriate interventions can be promptly delivered. One such innovation is the use of device-based diagnostic parameters in HF patients with implantable cardioverter defibrillators (ICD and/or cardiac resynchronization therapy (CRT devices. These diagnostic algorithms can effectively monitor and detect changes in patients' HF status, as well as predict one's risk of HF hospitalization. This paper will review the role of these device diagnostics parameters in the assessment and management of HF patients in ambulatory settings. In addition, the integration of these novel algorithms in existing HF disease management models will be discussed.

  5. Overview of the Exploration Exercise Device Validation Study Plans

    Science.gov (United States)

    DeWitt, J. K.; Swan, B. G.

    2018-01-01

    The NASA has determined that a multi-functional exercise device will be developed for use as an exercise device during exploration missions. The device will allow for full body resistance and metabolic exercise necessary to minimize physiological losses during space flight and to maintain fitness necessary to perform critical mission tasks. Prior to implementation as an exercise device on an Exploration vehicle, there will be verification and validation testing completed to determine device efficacy at providing the necessary training stimuli to achieve desired goals. Because the exploration device will be new device that has yet be specified, specific Verification and Validation (V&V) protocols have yet to be developed. Upon delivery of an exploration exercise device training unit, stakeholders throughout NASA will develop V&V plans that include ground-based testing and testing on the International Space Station (ISS). Stakeholders will develop test protocols that include success criterion for the device. Ground tests will occur at NASA Johnson Space Station prior to flight testing. The intents of the ground tests are to allow crew, spaceflight medicine, science, engineering, Astronaut Strength, Conditioning, and Reconditioning staff, and others to gain experience in the best utilization of the device. The goal is to obtain an evidence base for recommending use of the device on the ISS. The developed protocol will be created to achieve multiple objectives, including determining if the device provides an adequate training stimulus for 5th - 95th percentile males and females, allows for exercise modalities that protect functional capability, and is robust and can withstand extensive human use. Although protocols are yet to be determined, current expectations include use of the device by test subjects and current crew in order to obtain quantitative and qualitative feedback. Information obtained during the ground tests may be used to influence device modifications

  6. Survey of hydrogen monitoring devices

    International Nuclear Information System (INIS)

    Lai, W.

    1981-01-01

    Presented are results of a survey of commercially available monitoring devices suitable for hydrogen detection in the secondary containment vessel of a nuclear power plant during the post postulated accident period. Available detectors were grouped into the following five classes: combustion, solid state, electrochemical, thermal conductivity, and absorption. The performance of most available sensors is likely to deteriorate when exposed to the postulated conditions which include moisture, which could be at high temperature, and radioactive noncondensibles. Of the commercial devices, those using metallic filament thermal conductivity detectors seem least susceptible to performance change. Absorption detectors are best suited for this monitoring task but the only available device is designed for pipeline corrosion assessment. Initiation of experimental study to assess apparent deficiencies of commercial detectors is recommended. Also recommended is an analytical/experimental effort to determine the optimum detector array for monitoring in the secondary containment vessels

  7. Design and Implementation of the Automatic Assessment System for the Command and Control Specialty in Ships

    Directory of Open Access Journals (Sweden)

    Zhang Hao

    2017-01-01

    Full Text Available On the basis of analyzing the actual demand of automated assessment system for the command and control specialty in ships, the thought of the overall design of automated assessment system for the command and control specialty in ships is given, and the concrete realization methods of the user login module, test paper operation module and system maintenance module are studied and demonstrated. The proposed design idea and implementation method of automated assessment system for the command and control specialty in ships is scientific, efficient and practical, and provides reference for the exploitation of automated assessment system for the command and control specialty in ships.

  8. Biometric authentication for a mobile personal device

    NARCIS (Netherlands)

    Tao, Q.; Veldhuis, Raymond N.J.

    2006-01-01

    Secure access is prerequisite for a mobile personal device (MPD) in a personal network (PN). An authentication method using biometrics, specifically face, is proposed in this paper. A fast face detection and registration method based on a Viola-Jones detector is implemented, and a

  9. A novel device for grasping assessment during functional tasks: preliminary results

    Directory of Open Access Journals (Sweden)

    Ana Carolinne Portela Rocha

    2016-02-01

    Full Text Available This paper presents a methodology and first results obtained in a study with a novel device that allows the analysis of grasping quality. Such a device is able to acquire motion information of upper limbs allowing kinetic of manipulation analysis as well. A pilot experiment was carried out with six groups of typically developing children aged between 5 and 10 years old, with 7-8 children in each one. The device, designed to emulate a glass, has an optical system composed by one digital camera and a special convex mirror that together allow image acquisition of grasping hand posture when it is grasped and manipulated. It also carries an Inertial Measurement Unit (IMU that captures motion data as acceleration, orientation, and angular velocities. The novel instrumented object is used in our approach to evaluate functional tasks performance in quantitative terms. During tests each child was invited to grasp the cylindrical part of the device that was placed on the top of a table, simulating the task of drinking a glass of water. In the sequence the child was oriented to transport the device back to the starting position and release it. The task was repeated 3 times for each child. A grasping hand posture evaluation is presented as an example to evaluate grasping quality. Additionally, motion patterns obtained with the triasl performed with the different groups are presented and discussed. This device is attractive due to its portable characteristics, the small size and its ability to evaluate grasping form. The results may be also useful to analyze the evolution of the rehabilitation process through reach-to-grasping movement and the grasping images analysis.

  10. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  11. Evaluation of novel algorithm embedded in a wearable sEMG device for seizure detection

    DEFF Research Database (Denmark)

    Conradsen, Isa; Beniczky, Sandor; Wolf, Peter

    2012-01-01

    We implemented a modified version of a previously published algorithm for detection of generalized tonic-clonic seizures into a prototype wireless surface electromyography (sEMG) recording device. The method was modified to require minimum computational load, and two parameters were trained...... on prior sEMG data recorded with the device. Along with the normal sEMG recording, the device is able to set an alarm whenever the implemented algorithm detects a seizure. These alarms are annotated in the data file along with the signal. The device was tested at the Epilepsy Monitoring Unit (EMU......) at the Danish Epilepsy Center. Five patients were included in the study and two of them had generalized tonic-clonic seizures. All patients were monitored for 2–5 days. A double-blind study was made on the five patients. The overall result showed that the device detected four of seven seizures and had a false...

  12. Device-free object tracking using passive tags

    CERN Document Server

    Han, Jinsong; Zhao, Kun; Jiang, Zhiping

    2014-01-01

    This SpringerBrief examines the use of cheap commercial passive RFID tags to achieve accurate device-free object-tracking. It presents a sensitive detector, named Twins, which uses a pair of adjacent passive tags to detect uncooperative targets (such as intruders). Twins leverages a newly observed phenomenon called critical state that is caused by interference among passive tags.The author expands on the previous object tracking methods, which are mostly device-based, and reveals a new interference model and their extensive experiments for validation. A prototype implementation of the Twins-ba

  13. Alternating Copolymers and Alternative Device Geometries for Organic Photovoltaics

    OpenAIRE

    Inganäs, Olle; Zhang, Fengling; Andersson, Mats R.

    2012-01-01

    The efficiency of conversion of light to electrical energy with the help of conjugated polymers and molecules is rapidly improving. The optical absorption properties of these materials can be designed, and implemented via molecular engineering. Full coverage of the solar spectrum is thus feasible. Narrow absorption spectra allow construction of tandem solar cells. The poor transport properties of these materials require thin devices, which limits optical absorption. Alternative device geometr...

  14. Quality Assurance in Custom Dental Devices: A Technologist's Perspective.

    Science.gov (United States)

    Griffin, Anthony

    2017-12-01

    Manufacturing of custom-made dental devices such as removable dentures, fixed prosthodontics and orthodontics are subject to the requirements of the Medical Devices Directive (MDD). Many dental laboratories often enhance these requirements by implementing quality assurance procedures that then provide enhanced consistency. this paper provides a dental technologist's view of some of the systems currently being used in dental laboratories to provide a quality assured product and associated issues.

  15. Improvements in or relating to semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, M

    1981-08-26

    A method of testing a field effect device for radiation hardness is described which does not involve irradiating the device. In a low temperature environment the conductance of the device is measured as a function of gate voltage at a first and at a second different substrate bias potential and by comparing the two an assessment of radiation hardness is made.

  16. Silicon based light-emitting materials and devices

    International Nuclear Information System (INIS)

    Chen Weide

    1999-01-01

    Silicon based light-emitting materials and devices are the key to optoelectronic integration. Recently, there has been significant progress in materials engineering methods. The author reviews the latest developments in this area including erbium doped silicon, porous silicon, nanocrystalline silicon and Si/SiO 2 superlattice structures. The incorporation of these different materials into devices is described and future device prospects are assessed

  17. Implementation of Transformer Protection by Intelligent Electronic Device for Different Faults

    OpenAIRE

    Y V Aruna, Beena S

    2015-01-01

    Protection of power system equipments was traditionally done by using electromagnetic relay, static relays, and numerical relays. At present the microprocessor based relays are replacing the old Electromagnetic relays because of their high level accuracy and fast operation. RET670(Transformer protection relay ), an IED (INTELLIGENT ELECTRONIC DEVICE) provides fast and selective protection, monitoring, and control of all types of transformer. The configured IED is tested under diff...

  18. Structural observation of long-span suspension bridges for safety assessment: implementation of an optical displacement measurement system

    International Nuclear Information System (INIS)

    Martins, L Lages; Ribeiro, A Silva; Rebordão, J M

    2015-01-01

    This paper addresses the implementation of an optical displacement measurement system in the observation scenario of a long-span suspension bridge and its contribution for structural safety assessment. The metrological background required for quality assurance of the measurements is described, namely, the system's intrinsic parameterization and integration in the SI dimensional traceability chain by calibration, including its measurement uncertainty assessment

  19. Networked Attached Devices at SNS

    CERN Document Server

    Blokland, W

    2003-01-01

    The Spallation Neutron Source (SNS) diagnostic instruments at Oak Ridge National Laboratory are based on the Network Attached Device (NAD) concept. Each pickup or sensor has its own resources such as timing, data acquisition and processing. NADs are individually connected to the network, thus reducing the brittleness inherent in tightly coupled systems. This architecture allows an individual device to fail or to be serviced or removed without disrupting other devices. This paper describes our implementation of the nearly 400 NADs to be deployed. The hardware consists of rack-mounted PCs with standard motherboards and PCI data-acquisition boards. The software environment is based on LabVIEW and EPICS. LabVIEW supports the agile development demanded by modern diagnostic systems. EPICS is the control system standard for the entire SNS facility. To achieve high performance, LabVIEW and EPICS communicate through shared memory. SNS diagnostics are developed by a multi-laboratory partnership including ORNL, BNL, LAN...

  20. Use of mobile devices in community health care: barriers and solutions to implementation.

    Science.gov (United States)

    Turner, Christopher

    2016-02-01

    Mobile devices allow clinicians to access electronic clinical systems away from traditional base locations. They have contributed to increased productivity and efficiency, and clinical staff also cite benefits to patient care. A selection of NHS trusts have participated in a national pilot to explore the benefits and drawbacks of this technology. Clinical engagement with frontline staff is essential to ensure the staff feel valued, listened to, and fully involved to ensure any change to existing practice is successful. Moreover, the training needs of the workforce require careful consideration. The provision of information technology (IT) support services is fundamental to ensure that staff receive the necessary assistance with any functionality issues they may experience with mobile devices to minimise the effect on clinical practice. Variability in internet connectivity may present as a challenge to clinical staff, and the benefits of complimentary offline working solutions should be considered. Barriers to the successful use of mobile devices should be reported as this may have a negative clinical effect on the safe delivery of patient care. Clinical staff need to be mindful of their obligations in relation to information governance, and should appreciate that the same consideration needs to be given to both paper and electronic records.